WorldWideScience

Sample records for absorption spectrometry gfaas

  1. Dispersive liquid-liquid microextraction (DLLME combined with graphite furnace atomic absorption spectrometry (GFAAS for determination of trace Cu and Zn in water Samples

    Directory of Open Access Journals (Sweden)

    Ghorbani A.

    2014-07-01

    Full Text Available Dispersive liquid-liquid microextraction (DLLME combined with graphite furnace atomic absorption spectrometry (GFAAS was proposed for the determination of trace amounts of Copper and Zinc ions using 8-hydroxyquinoline (8-HQ as chelating agent. Several factors influencing the microextraction efficiency of Cu and Zn and their subsequent determinations, such as pH, extraction and disperser solvent type and their volume, concentration of the chelating agent and extraction time were studied, and the optimized experimental conditions were established. After extraction, the enrichment factors were 25 and 26 for Cu and Zn, respectively. The detection limits of the method were 0.025 and 0.0033 μg/L for Cu and Zn, and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Cu and Zn were 8.51% and 7.41%, respectively.

  2. Freon (CHF3)-assisted atomization for the determination of titanium using ultrasonic slurry sampling-graphite furnace atomic absorption spectrometry (USS-GFAAS): a simple and advantageous method for solid samples.

    Science.gov (United States)

    Asfaw, Alemayehu; Wibetoe, Grethe

    2004-06-01

    A simple and advantageous method for the determination of titanium using graphite furnace atomic absorption spectrometry with slurry sampling has been developed. Titanium is one of the refractory elements that form thermally stable carbides in the graphite tube, which leads to severe memory effects. Trifluoromethane (Freon-23) was applied in the purge gas during the atomization step or alternatively just prior to the atomization to successfully eliminate the problems of carbide formation and increase the lifetime of the furnace tube which could be used for more than 600 heating cycles. A flow rate of 40 mL min(-1) (5% of Freon in argon) was used to obtain symmetrical peaks with no tailing. However, when the gas flow rate was too high (250 mL min(-1)) the peak-tailing and memory effects reappeared. Ti was determined in various materials covering a wide range of concentrations, from 2.8 microg g(-1) to 12% (m/m) Ti. The accuracy of the method was confirmed by analyzing certified reference materials (CRMs) or by comparing the results with those obtained using inductively coupled plasma-atomic emission spectrometry (ICP-AES) after decomposition of the samples. The materials analyzed were soil, plant, human hair, coal, urban particulate matters, toothpaste, and powdered paint.

  3. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference ...

  4. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review.

    Science.gov (United States)

    de la Calle, Inmaculada; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2016-09-14

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Bismuth as a general internal standard for lead in atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bechlin, Marcos A.; Fortunato, Felipe M.; Ferreira, Edilene C.; Neto, José A. Gomes; Nóbrega, Joaquim A.; Donati, George L.; Jones, Bradley T.

    2014-01-01

    Highlights: • Single internal standard is commonly proposed for definite application in AAS. • Internal standard for general use in AAS techniques is original. • Bi showed efficiency as internal standard for Pb determinations by FAAS and GFAAS. • Assorted samples were analyzed and accurate results were found. - Abstract: Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A Pb /A Bi versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52–118% (without IS) to 97–109% (IS, LS FAAS); 74–231% (without IS) to 96–109% (IS, HR-CS FAAS); and 36–125% (without IS) to 96–110% (IS, LS GFAAS). The relative standard deviations (n = 12) were reduced from 0.6–9.2% (without IS) to 0.3–4.3% (IS, LS FAAS); 0.7–7.7% (without IS) to 0.1–4.0% (IS, HR-CS FAAS); and 2.1–13% (without IS) to 0.4–5.9% (IS, LS GFAAS)

  6. Bismuth as a general internal standard for lead in atomic absorption spectrometry.

    Science.gov (United States)

    Bechlin, Marcos A; Fortunato, Felipe M; Ferreira, Edilene C; Gomes Neto, José A; Nóbrega, Joaquim A; Donati, George L; Jones, Bradley T

    2014-06-11

    Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A(Pb)/A(Bi)versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52-118% (without IS) to 97-109% (IS, LS FAAS); 74-231% (without IS) to 96-109% (IS, HR-CS FAAS); and 36-125% (without IS) to 96-110% (IS, LS GFAAS). The relative standard deviations (n=12) were reduced from 0.6-9.2% (without IS) to 0.3-4.3% (IS, LS FAAS); 0.7-7.7% (without IS) to 0.1-4.0% (IS, HR-CS FAAS); and 2.1-13% (without IS) to 0.4-5.9% (IS, LS GFAAS). Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Haswell, S.J.

    1991-01-01

    Atomic absorption spectroscopy is now well established and widely used technique for the determination of trace and major elements in a wide range analyte types. There have been many advances in the atomic spectroscopy over the last decade and for this reason and to meet the demand, it was felt that there was a need for an updated book. Whilst interest in instrumental design has tended to dominate the minds of the spectrocopist, the analyst concerned with obtaining reliable and representative data, in diverse areas of application, has been diligently modifying and developing sample treatment and instrumental introduction techniques. Such methodology is de fundamental part of analysis and form the basis of the fourteen application chapters of this book. The text focuses in the main on AAS; however, the sample handling techniques described are in many cases equally applicable to ICP-OES and ICP-MS analysis. (author). refs.; figs.; tabs

  8. Flame emission, atomic absorption and fluorescence spectrometry

    International Nuclear Information System (INIS)

    Horlick, G.

    1980-01-01

    Six hundred and thirty references are cited in this review. The information in the review is divided into 12 major areas: books, reviews, and bibliographies; fundamental studies in flames; developments in instrumentation; measurement techniques and procedure; flame emission spectrometry; flame atomic absorption spectrometry; flame molecular absorption spectrometry; electrothermal atomization atomic absorption spectroscopy; hydride generation techniques; graphite furnace atomic emission spectrometry; atomic fluorescence spectrometry; and analytical comparisons

  9. Determination of trace elements in paints by direct sampling graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bentlin, Fabrina R.S. [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, UFRGS, 91501-970 Porto Alegre, RS (Brazil); Pozebon, Dirce [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, UFRGS, 91501-970 Porto Alegre, RS (Brazil)], E-mail: dircepoz@iq.ufrgs.br; Mello, Paola A.; Flores, Erico M.M. [Departamento de Quimica, Universidade Federal de Santa Maria, UFSM, 97105-900 Santa Maria, RS (Brazil)

    2007-10-17

    A direct sampling graphite furnace atomic absorption spectrometric (DS-GFAAS) method for the determination of Cd, Pb, Cr, Ni, Co and Cu in paints has been developed. Serigraphy, acrylic and tattoo paints were analysed. Approaches like pyrolysis and atomization temperatures, modifiers and sample mass introduced in the atomizer were studied. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the platform. The sample mass introduced in the graphite tube ranged from 0.02 to 8.0 mg. Palladium was used as modifier for Cd, Pb and Cu, while Mg(NO{sub 3}){sub 2} was used for Co. For Ni determination, the graphite platform was covered with carbon powder. The characteristic masses of Cd, Pb, Cr, Ni, Co and Cu were 1.4, 22.5, 7.9, 11.0, 9.6 and 12.5 pg, while the limits of detection were 0.0004, 0.001, 0.03, 0.22, 0.11 and 0.05 {mu}g g{sup -1} of Cd, Pb, Cr, Ni, Co and Cu, respectively. The accuracy was determined by comparison of the results with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS), using liquid sampling of digests. For matrix characterization, major and minor elements (Al, Mg, Ba, Ca, Cr, Cu, Pb, Sr, Ti and Mg) were determined by inductively coupled plasma optical emission spectrometry (ICP OES)

  10. Determination of trace elements in paints by direct sampling graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bentlin, Fabrina R.S.; Pozebon, Dirce; Mello, Paola A.; Flores, Erico M.M.

    2007-01-01

    A direct sampling graphite furnace atomic absorption spectrometric (DS-GFAAS) method for the determination of Cd, Pb, Cr, Ni, Co and Cu in paints has been developed. Serigraphy, acrylic and tattoo paints were analysed. Approaches like pyrolysis and atomization temperatures, modifiers and sample mass introduced in the atomizer were studied. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the platform. The sample mass introduced in the graphite tube ranged from 0.02 to 8.0 mg. Palladium was used as modifier for Cd, Pb and Cu, while Mg(NO 3 ) 2 was used for Co. For Ni determination, the graphite platform was covered with carbon powder. The characteristic masses of Cd, Pb, Cr, Ni, Co and Cu were 1.4, 22.5, 7.9, 11.0, 9.6 and 12.5 pg, while the limits of detection were 0.0004, 0.001, 0.03, 0.22, 0.11 and 0.05 μg g -1 of Cd, Pb, Cr, Ni, Co and Cu, respectively. The accuracy was determined by comparison of the results with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS), using liquid sampling of digests. For matrix characterization, major and minor elements (Al, Mg, Ba, Ca, Cr, Cu, Pb, Sr, Ti and Mg) were determined by inductively coupled plasma optical emission spectrometry (ICP OES)

  11. Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Resano, M.; Briceno, J.; Belarra, M.A.

    2009-01-01

    This work explores the potential of solid sampling-graphite furnace atomic absorption spectrometry (SS-GFAAS) for the fast and direct determination of Hg in polymers. Eight certified reference materials with different composition (polyethylene-PE-, polystyrene-PS-, poly vinyl chloride-PVC- and acrylonitrile butadiene styrene-ABS-) were selected for the study, covering a wide Hg content range (from 20 to 1100 μg g - 1 ). The difficulties found in achieving a selective atomization of the analyte from these samples were partially mitigated by the maintenance of the Ar flow during the atomization step, leading to an improved signal-to-background ratio. Even then, when a line source (LS) GFAAS instrument was employed for analysis, it was only possible to develop truly accurate procedures relying on the use of aqueous standards for calibration for PE and PVC samples, and different atomization conditions (1200 deg. C and 1300 deg. C, respectively) were needed for the two types of samples. The use of high-resolution continuum source (HR-CS) GFAAS instrumentation permitted to improve this situation significantly thanks to its higher potential for the correction of high and fast changing background. With such an instrument, satisfactory results could be obtained for all the samples under study using the same atomization conditions (1200 deg. C) and aqueous standard solutions for calibration. Additionally, the HR-CS GFAAS technique presented a lower limit of detection (0.6 μg g - 1 for CS and 2.2 μg g - 1 for LS), a broader linear range (10 to 320 Hg ng for CS, and 20 to 200 ng for LS), and a somewhat improved sensitivity (approximately 0.0030 s ng - 1 for CS using the three central pixels for quantification, and approximately 0.0025 s ng - 1 for LS). Overall, the use of HR-CS GFAAS permits obtaining significant advantages for the determination of this complex analyte in plastics, such as straightforward calibration with aqueous standards, a high sample throughput (15 min

  12. Flame and graphite furnace atomic absorption spectrometry for trace element determination in vegetable oils, margarine and butter after sample emulsification.

    Science.gov (United States)

    Ieggli, C V S; Bohrer, D; Do Nascimento, P C; De Carvalho, L M

    2011-05-01

    Trace element analysis plays an important role in oil characterisation and in the detection of oil adulteration because the quality of edible oils and fats is affected by their trace metal content. In this study, the quantification of selected metals in various oils and fats (rice oil, canola oil, sunflower oil, corn oil, soy oil, olive oil, light margarine, regular margarine and butter) was carried out using flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after sample emulsification. FAAS was used to determine the Na, K, Ca, Mg, Zn and Fe levels in the samples, while GFAAS was used for quantifying Cr, Ni, As, Pb, Cd, Cu and Mn, as these elements appeared in the samples at much lower concentrations. Tween-80 and Triton X-100 were employed as surfactants, and emulsions were prepared by a conventional method that involved heating and mixing of the constituents. Complete stabilisation was achieved through magnetic stirring for 15 min at room temperature. The evaluated figures of merit were linearity, accuracy and sensitivity, which were determined by the characteristic concentration and mass. Analysis of spiked samples demonstrated accuracy, which ranged from 90% (Na) to 112% (Fe) for FAAS and from 83% (Cd) to 121% (Pb) for GFAAS measurements. Atomic absorption spectrometry proved to be a promising approach for the analysis of metals in emulsified edible oils and fats. Additionally, under appropriate emulsification conditions (formulation, stirring time and temperature), the emulsions were homogeneous, had excellent stability, and had appropriate viscosity. The proposed method has proved to be simple, sensitive, reproducible, and economical.

  13. Determination of gold and cobalt dopants in advanced materials based on tin oxide by slurry sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Filatova, Daria G.; Eskina, Vasilina V.; Baranovskaya, Vasilisa B.; Vladimirova, Svetlana A.; Gaskov, Alexander M.; Rumyantseva, Marina N.; Karpov, Yuri A.

    2018-02-01

    A novel approach is developed for the determination of Co and Au dopants in advanced materials based on tin oxide using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with direct slurry sampling. Sodium carboxylmethylcellulose (Na-CMC) is an effective stabilizer for diluted suspensions. Use Na-CMC allows to transfer the analytes into graphite furnace completely and reproducibly. The relative standard deviation obtained by HR CS GFAAS was not higher than 4%. Accuracy was proven by means inductively coupled plasma mass spectrometry (ICP-MS) in solutions after decomposition as a comparative technique. To determine Au and Co in the volume of SnO2, the acid decomposition conditions (HCl, HF) of the samples were suggested by means of an autoclave in a microwave oven.

  14. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  15. [Graphite furnace atomic absorption spectrometry for determination of thallium in blood].

    Science.gov (United States)

    Zhang, Q L; Gao, G

    2016-04-20

    Colloidal palladium was used as chemical modifier in the determination of blood thallium by graphite furnace atomic absorption spectrometry. Blood samples were precipitated with 5% (V/V)nitric acid, and then determined by GFAAS with colloidal palladium used as a chemical modifier. 0.2% (W/V)sodium chloride was added in the standard series to improve the matrix matching between standard solution and sample. The detection limit was 0.2 μg/L. The correlation coefficient was 0.9991. The recoveries were between 93.9% to 101.5%.The relative standard deviations were between 1.8% to 2.7%.The certified reference material of whole blood thallium was determined and the result was within the reference range Conclusion: The method is accurate, simple and sensitive, and it can meet the needs of detection thallium in blood entirely.

  16. Preconcentration of trace elements from high-purity thorium and uranium on Chelex-100 and determination by graphite furnace atomic absorption spectrometry with Zeeman-effect background correction

    International Nuclear Information System (INIS)

    Raje, Naina; Kayasth, Satish; Asari, T.P.S.; Gangadharan, S.

    1994-01-01

    Preconcentration of trace impurities from large-sized samples of uranium metal and thorium oxide using a small column of Chelex-100 followed by their determination using graphite furnace atomic absorption spectrometry (GFAAS) is reported. A 0.5-10-g amount of the sample (uranium metal or thorium oxide) was dissolved, complexed with ammonium carbonate and subjected to the ion-exchange procedure. The retained analytes were eluted with 2-4 M nitric acid and brought to a small volume for a final dilution to 10-25 ml for their determination using GFAAS. The validity of the separation procedure and recoveries at μg kg -1 levels was checked by standard addition; the recoveries were >95%

  17. Optimization of Flame Atomic Absorption Spectrometry for ...

    African Journals Online (AJOL)

    Optimization of Flame Atomic Absorption Spectrometry for Measurement of High Concentrations of Arsenic and Selenium. ... This procedure allowed a rapid determination of As from minimum 4.462 mg/L to higher concentrations without sample pretreatment. Besides As, this method successfully measured Se concentrations ...

  18. Cadmium determination in lettuce grown in contaminated soil by INAAA and GFAAS

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko; Trevizam, Anderson R.; Silva, Maria Ligia S.; Muraoka, Takashi

    2011-01-01

    Although Cd is not essential for the mammalian organism, it follows in body the same pathways of essential elements such as zinc and copper. There is evidence that the Cd induced reduction of Ca absorption, may lead to the development of osteoporosis. Anthropogenic activities associated with industrial activities, mining and use of fertilizers, limestone pesticides in agriculture are the main sources of Cd enrichment in soils. Due to the possibility that Cd being absorbed by plants and through them to reach the food chain, interest has increased in regard to developing techniques for remediation of contaminated sites. The addition of substances capable of immobilizing the toxic elements from the soil is a procedure that has been used for remediation of contaminated sites. The function of these substances is to reduce the mobility and bioavailability of potentially toxic elements in the soil. In this study, five doses of phosphorus as triple phosphorus were used in a number of lettuce plants grown in contaminated soil. The concentration of Cd present in lettuce leaves treated with phosphate was compared with the Cd absorbed by the control plant leaves. Instrumental Neutron Activation Analysis (INAA) and Graphite-Furnace Absorption Atomic Spectrometry (GFAAS) were the analytical methods used to determine Cd contents in lettuce leaves. The objective was to evaluate the performance of the employed analytical methods: INAA and GFAAS in the assessment of the efficiency of phosphorus treatments to reduce the Cd concentrations in leaves of lettuce. Results obtained indicated that both analytical methods were efficient to discriminate the response of Cd concentration in lettuce as a function of soil treatment with phosphorus. Although INAA has shown a positive performance in this study, GFAAS seemed more appropriate because its sensitivity was much higher than that obtained by INAA, in the experimental conditions. (author)

  19. Cadmium determination in lettuce grown in contaminated soil by INAAA and GFAAS

    Energy Technology Data Exchange (ETDEWEB)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko, E-mail: marmelin@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Trevizam, Anderson R.; Silva, Maria Ligia S. [Universidade Estadual do Centro Oeste (UNICENTRO), Guarapuava, PR (Brazil); Muraoka, Takashi, E-mail: muraoka@cena.usp.b [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2011-07-01

    Although Cd is not essential for the mammalian organism, it follows in body the same pathways of essential elements such as zinc and copper. There is evidence that the Cd induced reduction of Ca absorption, may lead to the development of osteoporosis. Anthropogenic activities associated with industrial activities, mining and use of fertilizers, limestone pesticides in agriculture are the main sources of Cd enrichment in soils. Due to the possibility that Cd being absorbed by plants and through them to reach the food chain, interest has increased in regard to developing techniques for remediation of contaminated sites. The addition of substances capable of immobilizing the toxic elements from the soil is a procedure that has been used for remediation of contaminated sites. The function of these substances is to reduce the mobility and bioavailability of potentially toxic elements in the soil. In this study, five doses of phosphorus as triple phosphorus were used in a number of lettuce plants grown in contaminated soil. The concentration of Cd present in lettuce leaves treated with phosphate was compared with the Cd absorbed by the control plant leaves. Instrumental Neutron Activation Analysis (INAA) and Graphite-Furnace Absorption Atomic Spectrometry (GFAAS) were the analytical methods used to determine Cd contents in lettuce leaves. The objective was to evaluate the performance of the employed analytical methods: INAA and GFAAS in the assessment of the efficiency of phosphorus treatments to reduce the Cd concentrations in leaves of lettuce. Results obtained indicated that both analytical methods were efficient to discriminate the response of Cd concentration in lettuce as a function of soil treatment with phosphorus. Although INAA has shown a positive performance in this study, GFAAS seemed more appropriate because its sensitivity was much higher than that obtained by INAA, in the experimental conditions. (author)

  20. Spectral interferences in atomic absorption spectrometry, (5)

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1979-01-01

    Spectral interferences were observed in trace element analysis of concentrated solutions by atomic absorption spectrometry. Molecular absorption and emission spectra for strontium chloride and nitrate, barium chloride and nitrate containing 12 mg/ml of metal ion in airacetylene flame were measured in the wavelength range from 200 to 700 nm. The absorption and emission spectra of SrO were centered near 364.6 nm. The absorption spectra of SrOH around 606.0, 671.0 and 682.0 nm were very strong. And, emission spectrum of BaOH in the wavelength range from 480 to 550 nm was stronger. But, the absorption of this band spectrum was very weak. In the wavelength range from 200 to 400 nm, some unknown bands of absorption were observed for strontium and barium. Absorption spectra of SrCl and BaCl were observed in the argon-hydrogen flame. Also, in the carbon tube atomizer, the absorption spectra of SrCl and BaCl were detected clearly in the wavelength range from 185 to 400 nm. (author)

  1. Study of the roles of chemical modifiers in determining boron using graphite furnace atomic absorption spectrometry and optimization of the temperature profile during atomization.

    Science.gov (United States)

    Yamamoto, Yuhei; Shirasaki, Toshihiro; Yonetani, Akira; Imai, Shoji

    2015-01-01

    The measurement conditions for determining boron using graphite furnace-atomic absorption spectrometry (GF-AAS) were investigated. Differences in the boron absorbance profiles were found using three different commercially available GF-AAS instruments when the graphite atomizers in them were not tuned. The boron absorbances found with and without adjusting the graphite atomizers suggested that achieving an adequate absorbance for the determination of boron requires a sharp temperature profile that overshoots the target temperature during the atomization process. Chemical modifiers that could improve the boron absorbance without the need for using coating agents were tested. Calcium carbonate improved the boron absorbance but did not suppress variability in the peak height. Improvement of boron absorbance was comparatively less using iron nitrate or copper nitrate than using calcium carbonate, but variability in the peak height was clearly suppressed using iron nitrate or copper nitrate. The limit of detection was 0.0026 mg L(-1) when iron nitrate was used. It appears that iron nitrate is a useful new chemical modifier for the quick and simple determination of boron using GF-AAS.

  2. Metallomic study on plasma samples from Nile tilapia using SR-XRF and GFAAS after separation by 2D PAGE: Initial results

    International Nuclear Information System (INIS)

    Santos, F.A.; Lima, P.M.; Neves, R.C.F.; Moraes, P.M.; Castro, G.R.; Padilha, P.M.; Perez, C.A.; Silva, M.O.A.; Arruda, M.A.Z.

    2011-01-01

    An investigation was made on plasma samples obtained after protein separation. The proteome of the plasma of Nile tilapia (Oreochromis niloticus) was separated by 2D PAGE, and manganese and zinc in protein spots was qualitatively and quantitatively determined by synchrotron radiation X-ray fluorescence (SR-XRF) and graphite furnace atomic absorption spectrometry (GFAAS). Manganese and zinc are present in four and six plasma protein spots, respectively. These ions are bound to proteins with molecular weights ranging from 19 to 70 kDa and with isoelectric point (pI) ranging from 4.7 to 6.3. The concentrations of manganese and zinc bound to these proteins as determined by GFAAS following acid digestion of the spots range from 0.8 to 2.6 mg of manganese, and from 1.0 to 6.3 mg of zinc, respectively, per g of protein. (author)

  3. [Development of ICP-OES, ICP-MS and GF-AAS Methods for Simultaneous Quantification of Lead, Total Arsenic and Cadmium in Soft Drinks].

    Science.gov (United States)

    Kataoka, Yohei; Watanabe, Takahiro; Hayashi, Tomoko; Teshima, Reiko; Matsuda, Rieko

    2015-01-01

    In this study, we developed methods to quantify lead, total arsenic and cadmium contained in various kinds of soft drinks, and we evaluated their performance. The samples were digested by common methods to prepare solutions for measurement by ICP-OES, ICP-MS and graphite furnace atomic absorption spectrometry (GF-AAS). After digestion, internal standard was added to the digestion solutions for measurements by ICP-OES and ICP-MS. For measurement by GF-AAS, additional purification of the digestion solution was conducted by back-extraction of the three metals into nitric acid solution after extraction into an organic solvent with ammonium pyrrolidine dithiocarbamate. Performance of the developed methods were evaluated for eight kinds of soft drinks.

  4. A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    A. A. Asweisi

    2010-01-01

    Full Text Available A new crossed graphite furnace for atomic absorption spectrometry (GFAAS was designed and installed in heated graphite atomizer (HGA500 combined with Perkin-Elmer spectrometer (AAS1100. The Tungsten ballast body was inserted inside one part of the crossed furnace in a way perpendicular to light path. The analyzed sample was injected manually on the ballast body inside the cross and pushed into the measuring zone using the original inner and additional purge gas. The sample was adsorbed strongly on the ballast and evaporated and transferred with different rates at different temperatures during the temperature program allowing the separation of analyte and matrix signals. Analysis of middle volatile element such as copper and manganese in standard urine sample (seronorm 2525 showed complete separation of analyte and background signals with good sensitivity and repeatability.

  5. Direct determination of Cu, Mn, Pb, and Zn in beer by thermospray flame furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Nascentes, Clesia C.; Kamogawa, Marcos Y.; Fernandes, Kelly G.; Arruda, Marco A.Z.; Nogueira, Ana Rita A.; Nobrega, Joaquim A.

    2005-01-01

    In this work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu, Mn, Pb, and Zn determination in beer without any sample digestion. The system was optimized and calibration was based on the analyte addition technique. A sample volume of 300 μl was introduced into the hot Ni tube at a flow-rate of 0.4 ml min -1 using 0.14 mol l -1 nitric acid solution or air as carrier. Different Brazilian beers were directly analyzed after ultrasonic degasification. Results were compared with those obtained by graphite furnace atomic absorption spectrometry (GFAAS). The detection limits obtained for Cu, Mn, Pb, and Zn in aqueous solution were 2.2, 18, 1.6, and 0.9 μg l -1 , respectively. The relative standard deviations varied from 2.7% to 7.3% (n=8) for solutions containing the analytes in the 25-50 μg l -1 range. The concentration ranges obtained for analytes in beer samples were: Cu: 38.0-155 μg l -1 ; Mn: 110-348 μg l -1 , Pb: 13.0-32.9 μg l -1 , and Zn: 52.7-226 μg l -1 . Results obtained by TS-FF-AAS and GFAAS were in agreement at a 95% confidence level. The proposed method is fast and simple, since sample digestion is not required and sensitivity can be improved without using expensive devices. The TS-FF-AAS presented suitable sensitivity for determination of Cu, Mn, Pb, and Zn in the quality control of a brewery

  6. Acquisition and analysis of GFAAS data

    OpenAIRE

    Adams, M. J.; Ewen, G. J.; Shand, C. A.

    1988-01-01

    Since its inception as an analytical technique some 30 years ago atomic absorption spectrometry has become a firmly established method for the analysis of trace metals. Graphite furnace atomic absorption spectrometry provides the analyst with the capability of analysis of solutions containing μg l-1 levels of the analyte, but, because of the transient nature of the signals, a sophisticated approach to the data aquisition and handling of data is required. Most modern commercial graphite furnac...

  7. Determination of trace elements in lithium niobate crystals by solid sampling and solution-based spectrometry methods

    Energy Technology Data Exchange (ETDEWEB)

    Bencs, Laszlo, E-mail: bencs.laszlo@wigner.mta.hu [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Gyoergy, Krisztina; Kardos, Marta [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Osan, Janos; Alfoeldy, Balint [Institute for Atomic Energy Research, Centre for Energy Research, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Varga, Imre [Department of Analytical Chemistry, Institute of Chemistry, Lorand Eoetvoes University, P.O. Box 32, H-1518 Budapest (Hungary); Ajtony, Zsolt [Institute of Food Science, University of West Hungary, H-9200 Mosonmagyarovar, Lucsony u. 15-17 (Hungary); Szoboszlai, Norbert [Department of Analytical Chemistry, Institute of Chemistry, Lorand Eoetvoes University, P.O. Box 32, H-1518 Budapest (Hungary); Stefanka, Zsolt [Institute for Isotope Research, Centre for Energy Research, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Hungarian Atomic Energy Authority, H-1136 Budapest, Fenyes Adolf u. 4 (Hungary); Szeles, Eva [Institute for Isotope Research, Centre for Energy Research, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Kovacs, Laszlo [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary)

    2012-05-13

    Highlights: Black-Right-Pointing-Pointer Solid sampling GFAAS was studied for Cr, Fe and Mn determination in lithium niobate. Black-Right-Pointing-Pointer Solution based GFAAS, FAAS, ICP-OES and ICP-MS were elaborated for method validation. Black-Right-Pointing-Pointer The performances of the elaborated spectrochemical methods have been compared. Black-Right-Pointing-Pointer The chemical forms of the matrix produced in GFAAS cycles were studied by XANES. - Abstract: Solid sampling (SS) graphite furnace atomic absorption spectrometry (GFAAS) and solution-based (SB) methods of GFAAS, flame atomic absorption spectrometry (FAAS), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) were elaborated and/or optimized for the determination of Cr, Fe and Mn trace elements used as dopants in lithium niobate optical crystals. The calibration of the SS-GFAAS analysis was possible with the application of the three-point-estimation standard addition method, while the SB methods were mostly calibrated against matrix-matched and/or acidic standards. Spectral and non-spectral interferences were studied in SB-GFAAS after digestion of the samples. The SS-GFAAS method required the use of less sensitive spectral lines of the analytes and a higher internal furnace gas (Ar) flow rate to decrease the sensitivity for crystal samples of higher (doped) analyte content. The chemical forms of the matrix produced at various stages of the graphite furnace heating cycle, dispensed either as a solid sample or a solution (after digestion), were studied by means of the X-ray near-edge absorption structure (XANES). These results revealed that the solid matrix vaporized/deposited in the graphite furnace is mostly present in the metallic form, while the dry residue from the solution form mostly vaporized/deposited as the oxide of niobium.

  8. Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Zambrzycka-Szelewa, Elżbieta; Lulewicz, Marta; Godlewska-Żyłkiewicz, Beata

    2017-07-01

    In the present paper a fast, simple and sensitive analytical method for simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) was developed. Among six pairs of absorption atomic lines of Rh and Ru, which are close enough to enable their simultaneous detection, two pairs were selected for further studies. Best results were obtained for measurements of the resonance line of rhodium at 343.489 nm and the adjacent secondary line of ruthenium at 343.674 nm (23% intensity of this line). For evaluated lines, the absorbance values were obtained using three pixels. The pyrolysis and atomization temperatures were 1200 °C and 2600 °C, respectively. Under these conditions the limits of detection achieved for Rh and Ru were found to be 1.0 μg L- 1 and 1.9 μg L- 1, respectively. The characteristic mass was 12.9 pg for Rh and 71.7 pg for Ru. Repeatability of the results expressed as a relative standard deviation was typically below 6%. The trueness of the method was confirmed by analysis of the certified reference material - platinum ore (SARM 76). The recovery of Rh and Ru from the platinum ore was 93.0 ± 4.6% and 90.1 ± 2.5%, respectively. The method was successfully applied to the direct simultaneous determination of trace amounts of rhodium and ruthenium in spiked river water, road runoff, and municipal sewage. Separation of interfering matrix on cation exchange resin was required before analysis of road dust and tunnel dust (CW-7) by HR-CS GFAAS.

  9. Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Man Xiao

    2017-01-01

    Full Text Available Background Platinum-based agents are widely used in chemotherapy against solid tumors and insufficient intracellular drug accumulation is one of the leading causes of platinum resistance which is associated with poor survival of tumor patients. Thus, the detection of intracellular platinum is pivotal for studies aiming to overcome platinum resistance. In the present study, we aimed to establish a reliable graphite furnace atomic absorption spectrometry (GFAAS-based assay to quantify the intracellular platinum content for cultured cells. Methods Several most commonly applied cell preparation methods, including 0.2% HNO3, 0.2% Triton X-100, concentrated nitric acid, RIPA combined with concentrated nitric acid and hydroxide, followed by GFAAS for platinum detection were compared in ovarian, cervical and liver cancer cell lines to obtain the optimal one, and parameters regarding linearity, accuracy, precision and sensitivity were evaluated. Influence of other metals on platinum detection and the storage conditions of samples were also determined. Results The treatment of cells with 0.2% HNO3 was superior to other approaches with fewer platinum loss and better repeatability. The recovery rate and precision of this method were 97.3%–103.0% and 1.4%–3.8%, respectively. The average recoveries in the presence of other metals were 95.1%–103.1%. The detection limit was 13.23 ug/L. The recovery rate of platinum remained acceptable even in cell samples stored in −20 °C or −80 °C for two months. Discussion After comparison, we found that 0.2% HNO3 was optimal for intracellular platinum quantification based on GFAAS, which presented values compatible with that of inductively-coupled plasma mass-spectrometry (ICP-MS, and this is partially attributed to the simplicity of this method. Moreover, the assay was proved to be accurate, sensitive, cost-effective and suitable for the research of platinum-based antitumor therapy.

  10. Atomic Absorption, Atomic Fluorescence, and Flame Emission Spectrometry.

    Science.gov (United States)

    Horlick, Gary

    1984-01-01

    This review is presented in six sections. Sections focus on literature related to: (1) developments in instrumentation, measurement techniques, and procedures; (2) performance studies of flames and electrothermal atomizers; (3) applications of atomic absorption spectrometry; (4) analytical comparisons; (5) atomic fluorescence spectrometry; and (6)…

  11. The behavior of various chemical forms of nickel in graphite furnace atomic absorption spectrometry under different chemical modification approaches

    International Nuclear Information System (INIS)

    Kowalewska, Zofia

    2012-01-01

    Various organic and inorganic Ni forms were investigated using graphite furnace atomic absorption spectrometry. Experiments without chemical modification showed a wide range of characteristic mass values for Ni (from 6.7 to 29 pg) and the importance of interaction with graphite. With the aim of achieving signal unification of organic Ni forms, different ways of chemical modification were tested. Some rules that govern the behavior of Ni were found and confirmed a significant role of the organic component of the analyte molecule in the analytical process. The application of air as an internal furnace gas in the pyrolysis phase and the Pd modifier injected with the sample solution improved the signal of porphyrins, while the application of iodine and methyltrioctylammonium chloride was required for organic compounds containing oxygen-bound Ni atoms. The Ni signal was strongly diminished when an aqueous solution containing hydrochloric acid was measured with the Pd modifier injected over the sample. Using the developed analytical methods, the range of characteristic mass values for various Ni forms totally dissolved in organic or aqueous solution was 6.5–7.9 pg. - Highlights: ► Some rules that govern behavior of organic Ni forms during GFAAS analysis were found. ► Interaction with graphite can significantly influence evaporation of porphyrins. ► Determination of Ni in form of porphyrins needs Pd organic modifier and air ashing. ► Determination of Ni in O-bound organic compounds needs pretreatment with I2+MTOACl. ► Chemical modification for GFAAS determination of Ni in HCl-containing solution.

  12. Separation and preconcentration of platinum-group metals from spent autocatalysts solutions using a hetero-polymeric S, N-containing sorbent and determination by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Eskina, Vasilina V; Dalnova, Olga A; Filatova, Daria G; Baranovskaya, Vasilisa B; Karpov, Yuri A

    2016-10-01

    This paper describes the potential of high-resolution continuum source graphite furnace atomic absorption spectrometry for determination of Pt, Pd and Rh after separation and concentration by original in-house developed heterochain polymer S, N-containing sorbent. The methods of sample preparation of spent ceramic-based autocatalysts were considered, two of which were used: autoclave decomposition in mixture of acids HCl:HNO3 (3:1) and high-temperature melting with K2S2O7. Both methods anyway limit the direct determination of analytes by HR CS GFAAS. Using the first method it is an incomplete digestion of spent autocatalysts samples, since the precipitate is Si, and the rhodium metal dissolves with difficulty and partially passes into solution. In contrast to the first method, the second method allow to completely transfer analytes into solution, however, the background signal produced by the chemical composition of the flux, overlaps the analytical zone. It was found, that Pt, Pd and Rh contained in the spent ceramic automotive catalysts could be effectively separated and concentrated by heterochain polymer S, N-containing sorbent, which has high sorption capacity, selectivity and resistant to dilute acids. The chosen HR CS GFAAS analysis conditions enable us to determine Pt, Pd and Rh with good metrological characteristics. The concentrations of Pt, Pd and Rh in two samples of automobile exhaust catalysts were found in range of 0.00015-0.00050; 0.170-0.189; 0.0180-0.0210wt%, respectively. The relative standard deviation obtained by HR CS GFAAS was not more than 5%. Limits of detection by HR CS GFAAS achieved were 6.2·10(-6)wt% for Pt, 1.8·10(-6)wt% for Pd, and 3.4·10(-6)wt% for Rh. Limits of determination achieved by HR CS GFAAS were 1.1·10(-5)wt% for Pt, 6.9·10(-5)wt% for Pd, and 8.3·10(-5)wt% for Rh. To control the accuracy of PGM in sorption concentrates by HR CS GFAAS method, it was appropriate to conduct an inter-method comparative experiment. The

  13. Determination of hafnium by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yoshida, Isao; Kobayashi, Hiroshi; Ueno, Keihei.

    1977-01-01

    Optimum conditions for atomic absorption spectrophotometric determination of hafnium were investigated by use of a Jarrel-Ash AA-1 instrument which was equipped with a premixed gas burner slotted 50 mm in length and 0.4 mm in width. Absorption of hafnium, which was atomized in an nitrous oxide-acetylene flame, was measured on a resonance line at 307.29 nm. The absorption due to hafnium was enhanced in the presence of ammonium fluoride and iron(III) ion, as shown in Figs. 2 and 3, depending on their concentration. The highest absorption was attained by the addition of (0.15 -- 0.3)M ammonium fluoride, 0.07 M of iron(III) ion and 0.05 M of hydrochloric acid. An excess of the additives decreased the absorption. The presence of zirconium, which caused a significant interference in the ordinary analytical methods, did not affect the absorption due to hafnium, if the zirconium concentration is less than 0.2 M. A standard procedure was proposed; A sample containing a few mg of hafnium was dissolved in a 25-ml volumetric flask, and ammonium fluoride, ferric nitrate and hydrochloric acid were added so that the final concentrations were 0.3, 0.07 and 0.05 M, respectively. Atomic absorption was measured on the aqueous solution in a nitrous oxide-acetylene flame and the hafnium content was calculated from the absorbance. Sensitivity was as high as 12.5 μg of Hf/ml/l% absorption. The present method is especially recommendable to the direct determination of hafnium in samples containing zirconium. (auth.)

  14. Absorption Mode FTICR Mass Spectrometry Imaging

    NARCIS (Netherlands)

    Smith, D.F.; Kilgour, D.P.A.; Konijnenburg, M.; O'Connor, P.B.; Heeren, R.M.A.

    2013-01-01

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields

  15. Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Resano, M.; Mozas, E.; Crespo, C.; Pérez, J.; García-Ruiz, E.; Belarra, M.A.

    2012-01-01

    This paper reports on the use of solid sampling-graphite furnace atomic absorption spectrometry for the direct analysis of synthetic amorphous silica. In particular, determination of hazardous elements such As, Cd, Cr, Cu, Pb and Sb is investigated, as required by regulations of the food industry. The conclusion of the work is that, after proper optimization of the working conditions, paying particular attention to the atomization temperature and the use of proper modifiers (graphite powder, HNO 3 or Pd), it is possible to develop suitable procedures that rely on the use of aqueous standard solutions to construct the calibration curves for all the elements investigated. The proposed method shows important benefits for the cost-effective analysis of such difficult samples in routine labs, permitting fast screening of those elements that are very rarely present in this type of sample, but also accurate quantification of those often found, while offering low limits of detection (always below 0.1 mg g −1 ) that comply well with legal requirements, and precision levels that are fit for the purpose (approx. 6–9% R.S.D.). - Highlights: ► Solid sampling GFAAS is investigated for the direct analysis of silica samples; ► a fast and simple methodology with aqueous standards for calibration is proposed; ► this method permits accurate determination of As, Cd, Cr, Cu, Pb and Sb in the samples of interest; ► LODs below 100 ng g −1 and precision values in the 6–10% RSD range are achieved.

  16. Separation and enrichment of Ga and In with ion-exchange resin and their determination by platform graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Tang Senjin; Guan Guisheng

    1999-07-01

    The conditions for separating and enriching Ga and In with 003 x 7 ion-exchange resin and the determination of Ga and In by GFAAS (Graphite Furnace Atomic Absorption Spectrometry) are systematically studied. The Ni and V are used as the matrix modifier for the determination of Ga and In. In the range of pH 0.5-7, the Ga and In are adsorbed selectively, and eluted with a solution of 3 mol/L HNO 3 . the detection limit is down to 1.52 ng/ml for Ga, 0.976 ng/ml for In. Analytical results of national standard reference rock samples by this method conform to the recommended values

  17. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    Results: Mean recovery of three different samples of NHPs, using HGAAS and GFAAS, ranged from. 89.3 - 91.4 ... in trace amounts in various environmental ... Sample preparation. Natural herbal products originated from specific medicinal plants Eurycoma longifolia Tongkat Ali and Labisia pumila Kacip Fatimah in capsule.

  18. Determination of lead in rice grains by solid sampling HR-CS GFAAS.

    Science.gov (United States)

    Gunduz, Sema; Akman, Suleyman

    2013-12-01

    A study was performed for the determination of lead in rice grains directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) without digesting sample. The effects of sample amount, pyrolysis/atomization temperatures on the determination of lead in rice were investigated and optimized using a certificated rice flour. The lead concentrations were determined applying 800 °C of pyrolysis and 1800 °C of atomization temperatures without modifier. LOD (N=10, 3σ) and characteristic mass were 2.3 μg kg(-1) and 8.1 pg, respectively. The certified lead value of a rice flour CRM was found in its uncertainity limits. The lead contents of various rice samples obtained from markets in Turkey were between 0.009 and 0.162 mg kg(-1) which are in acceptable range. The average lead concentrations in various rice grains taken from the same package were significantly different from each other. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Acquisition and analysis of GFAAS data.

    Science.gov (United States)

    Adams, M J; Ewen, G J; Shand, C A

    1988-01-01

    Since its inception as an analytical technique some 30 years ago atomic absorption spectrometry has become a firmly established method for the analysis of trace metals. Graphite furnace atomic absorption spectrometry provides the analyst with the capability of analysis of solutions containing mug l(-1) levels of the analyte, but, because of the transient nature of the signals, a sophisticated approach to the data aquisition and handling of data is required. Most modern commercial graphite furnace atomic absorption spectrometers have built in microprocessors for this purpose but they often have limited capability for extensible user programs and limited data storage facilities. In this communication we describe the use of an Apple IIe microcomputer for the acquisition of data from a Pye Unicam SP9 graphite furnace atomic absorption spectrometer. Details of the interface which utilizes an in-house designed AD converter, and an overview of the Pascal and assembler programs employed are given. The system allows the user to record, store and dump the graphical display of the furnace signalsfor all analyses performed. Files containing details of peak height, and area are formatted on an eight-column spreadsheet. Details of sample type, concentrations of standards, dilutions and replication are entered from the keyboard. The calibration graph is constructed using a moving quadratic fit routine and the concentrations of the analyte in unknown solutions calculated. In addition to this, greater processing power and integration of the data into other analytical schemes can be achieved by exporting the data to other software packages and computers. Details of data transfer between the Apple IIe and an Amstrad PC 1512 are given. Some examples of the use of the system in the development of an analytical methodfor silver in plant material are given.

  20. Selective speciation of inorganic antimony on tetraethylenepentamine bonded silica gel column and its determination by graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Mendil, Durali; Bardak, Hilmi; Tuzen, Mustafa; Soylak, Mustafa

    2013-03-30

    A speciation system for antimony (III) and antimony (V) ions that based on solid phase extraction on tetraethylenepentamine bonded silica gel has been established. Antimony was determined by graphite furnace atomic absorption spectrometry (GF-AAS). Analytical conditions including pH, sample volume, etc., were studied for the quantitative recoveries of Sb (III) and Sb (V). Matrix effects on the recovery were also investigated. The recovery values and detection limit for antimony (III) at optimal conditions were found as >95% and 0.020 μg L(-1), respectively. Preconcentration factor was calculated as 50. The capacity of adsorption for the tetraethylenepentamine bonded silica gel was 7.9 mg g(-1). The validation was checked by analysis of NIST SRM 1573a Tomato laves and GBW 07605 Tea certified reference materials. The procedure was successfully applied to speciation of antimony in tap water, mineral water and spring water samples. Total antimony was determined in refined salt, unrefined salt, black tea, rice, tuna fish and soil samples after microwave digestion and presented enrichment method combination. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Molecular absorption spectrometry in flames and furnaces: A review

    International Nuclear Information System (INIS)

    Butcher, David J.

    2013-01-01

    Graphical abstract: -- Highlights: •Theory and analytical considerations for molecular absorption spectrometry (MAS). •Critical review of low resolution MAS. •Critical review of the analytical performance of high-resolution continuum source (HR-CS) flame MAS. •Critical review of the analytical performance of HR-CS graphite furnace MAS. •Current status of HR-CS MAS and its future prospects for elemental analysis. -- Abstract: Molecular absorption spectrometry (MAS), originally developed in the 1970s, is a technique to determine non-metals in flames and graphite furnaces by monitoring the absorbance of diatomic molecules. Early studies employed low resolution instruments designed for line source atomic absorption, which provided a limited choice of analytical wavelengths, insufficient spectral resolution, and spectral interferences. However, the development of high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) instrumentation has allowed the analysis of challenging samples for non-metals as well as some difficult elements to determine by AAS, such as aluminum and phosphorus. In this review, theory and analytical considerations for MAS are discussed. The principles and limitations of low resolution MAS are described, along with its applications. HR-CS AAS instrumentation is reviewed, emphasizing performance characteristics most relevant for MAS. Applications of flame and HR-CS GFMAS are reviewed, highlighting the most significant work to date. The paper concludes with an evaluation of the enhanced analytical capabilities provided by HR-CS MAS

  2. Molecular absorption spectrometry in flames and furnaces: A review

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, David J., E-mail: butcher@email.wcu.edu

    2013-12-04

    Graphical abstract: -- Highlights: •Theory and analytical considerations for molecular absorption spectrometry (MAS). •Critical review of low resolution MAS. •Critical review of the analytical performance of high-resolution continuum source (HR-CS) flame MAS. •Critical review of the analytical performance of HR-CS graphite furnace MAS. •Current status of HR-CS MAS and its future prospects for elemental analysis. -- Abstract: Molecular absorption spectrometry (MAS), originally developed in the 1970s, is a technique to determine non-metals in flames and graphite furnaces by monitoring the absorbance of diatomic molecules. Early studies employed low resolution instruments designed for line source atomic absorption, which provided a limited choice of analytical wavelengths, insufficient spectral resolution, and spectral interferences. However, the development of high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) instrumentation has allowed the analysis of challenging samples for non-metals as well as some difficult elements to determine by AAS, such as aluminum and phosphorus. In this review, theory and analytical considerations for MAS are discussed. The principles and limitations of low resolution MAS are described, along with its applications. HR-CS AAS instrumentation is reviewed, emphasizing performance characteristics most relevant for MAS. Applications of flame and HR-CS GFMAS are reviewed, highlighting the most significant work to date. The paper concludes with an evaluation of the enhanced analytical capabilities provided by HR-CS MAS.

  3. Absorption Mode FT-ICR Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O' Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  4. Determination of cadmium in aluminium by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Batistoni, D.A.; Erlijman, L.H.

    1978-12-01

    A direct method for the determination of cadmium in elemental aluminium is described. Metal samples are dissolved in diluted hydrochloric acid and cadmium is determined by atomic absorption spectrometry in an air-acetylene flame. Interference by non-specific absorption observed at the analytical wavelength incorrected for by means of a non-absorbing line emitted by the hollow-cathode lamp. Relatively large amounts of arsenic do not interfere. The minimun determinable concentration of cadmium for this procedure is 2-3 ppm, expressed on aluminium basis. (author) [es

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of arsenic and selenium in water and sediment by graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Jones, Sandra R.; Garbarino, John R.

    1999-01-01

    Graphite furnace-atomic absorption spectrometry (GF-AAS) is a sensitive, precise, and accurate technique that can be used to determine arsenic and selenium in samples of water and sediment. The GF-AAS method has been developed to replace the hydride generation-atomic absorption spectrometry (HG-AAS) methods because the method detection limits are similar, bias and variability are comparable, and interferences are minimal. Advantages of the GF-AAS method include shorter sample preparation time, increased sample throughput from simultaneous multielement analysis, reduced amount of chemical waste, reduced sample volume requirements, increased linear concentration range, and the use of a more accurate digestion procedure. The linear concentration range for arsenic and selenium is 1 to 50 micrograms per liter in solution; the current method detection limit for arsenic in solution is 0.9 microgram per liter; the method detection limit for selenium in solution is 1 microgram per liter. This report describes results that were obtained using stop-flow and low-flow conditions during atomization. The bias and variability of the simultaneous determination of arsenic and selenium by GF-AAS under both conditions are supported with results from standard reference materials--water and sediment, real water samples, and spike recovery measurements. Arsenic and selenium results for all Standard Reference Water Samples analyzed were within one standard deviation of the most probable values. Long-term spike recoveries at 6.25, 25.0, 37.5 micrograms per liter in reagent-, ground-, and surface-water samples for arsenic averaged 103 plus or minus 2 percent using low-flow conditions and 104 plus or minus 4 percent using stop-flow conditions. Corresponding recoveries for selenium were 98 plus or minus 13 percent using low-flow conditions and 87 plus or minus 24 percent using stop-flow conditions. Spike recoveries at 25 micrograms per liter in 120 water samples ranged from 97 to 99 percent

  6. Simultaneous determination of V, Ni and Fe in fuel fly ash using solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Cárdenas Valdivia, A; Vereda Alonso, E; López Guerrero, M M; Gonzalez-Rodriguez, J; Cano Pavón, J M; García de Torres, A

    2018-03-01

    A green and simple method has been proposed in this work for the simultaneous determination of V, Ni and Fe in fuel ash samples by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GFAAS). The application of fast programs in combination with direct solid sampling allows eliminating pretreatment steps, involving minimal manipulation of sample. Iridium treated platforms were applied throughout the present study, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9931. The concentrations found in the fuel ash samples analysed ranged from 0.66% to 4.2% for V, 0.23-0.7% for Ni and 0.10-0.60% for Fe. Precision (%RSD) were 5.2%, 10.0% and 9.8% for V, Ni and Fe, respectively, obtained as the average of the %RSD of six replicates of each fuel ash sample. The optimum conditions established were applied to the determination of the target analytes in fuel ash samples. In order to test the accuracy and applicability of the proposed method in the analysis of samples, five ash samples from the combustion of fuel in power stations, were analysed. The method accuracy was evaluated by comparing the results obtained using the proposed method with the results obtained by ICP OES previous acid digestion. The results showed good agreement between them. The goal of this work has been to develop a fast and simple methodology that permits the use of aqueous standards for straightforward calibration and the simultaneous determination of V, Ni and Fe in fuel ash samples by direct SS HR CS GFAAS. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Magnetic solid-phase extraction combined with graphite furnace atomic absorption spectrometry for speciation of Cr(III) and Cr(VI) in environmental waters.

    Science.gov (United States)

    Jiang, Hong-mei; Yang, Ting; Wang, Yan-hong; Lian, Hong-zhen; Hu, Xin

    2013-11-15

    A new approach of magnetic solid phase extraction (MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) has been developed for the speciation of Cr(III) and Cr(VI) using zincon-immobilized silica-coated magnetic Fe3O4 nanoparticles (Zincon-Si-MNPs) as the MSPE absorbent. Cr(III) was quantitatively reserved on the absorbent at pH 9.1 while total Cr was reserved at pH 6.5. The absorbed Cr species were eluted by using 2 mol/L HCl and detected by GFAAS. The concentration of Cr(VI) could be calculated by subtracting Cr(III) from total Cr. All the parameters affecting the separation and extraction efficiency of Cr species such as pH, extraction time, concentration and volume of eluent, sample volume and influence of co-existing ions were systematically examined and the optimized conditions were established accordingly. The detection limit (LOD) of the method was 0.016 and 0.011 ng mL(-1) for Cr(III) and Cr(VI), respectively, with the enrichment factor of 100 and 150. The precisions of this method (Relative standard deviation, RSD, n=7) for Cr(III) and Cr(VI) at 0.1 ng mL(-1) were 6.0% and 6.2%, respectively. In order to validate the proposed method, a certified reference material of environmental water was analyzed, and the result of Cr speciation was in good agreement with the certified value. This MSPE-GFAAS method has been successfully applied for the speciation of Cr(III) and Cr(VI) in lake and tap waters with the recoveries of 88-109% for the spiked samples. Moreover, the MSPE separation mechanism of Cr(III) and Cr(VI) based on their adsorption-desorption on Zincon-Si-MNPs has been explained through various spectroscopic characterization. © 2013 Elsevier B.V. All rights reserved.

  8. Determination of metals in atmospheric particulates using atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Alduan, F.A.; Capdevila, C.

    1979-01-01

    Nineteen trace metals in atmospheric samples have been determined by atomic absorption spectrometry, using a graphite furnace for most elements. Paper filters have been used to collect air samples. The sample preparation procedure involves the removal of organic matter and the conversion of the metals to soluble salts by ashing the filters in an oxygen plasma at 125 deg C for 6 h. and by subsequent dissolution in HN0 3 HCl solution. The sensitivities achieved are in the range of 2,5.10 -5 and 6,3.10 -3 μg/m 3 , for an air volume of 2000 m 3 . (author)

  9. Flow Injection and Atomic Absorption Spectrometry (FI-AAS) -

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    One of the advantages of the flow injection (FI) concept is that it is compatible with virtually all detection techniques. Being a versatile vehicle for enhancing the performance of the individual detection devices, the most spectacular results have possibly been obtained in conjunction with atomic...... absorption spectrometry (AAS). Initially with flame-AAS (fAAS) procedures, later for hydride generation (HG) techniques, and most recently in combination with electrothermal AAS (ETAAS). The common denominator for all these procedures is the inherently precise and strictly reproducible timing in FI from...

  10. Poly(1-vinylimidazole) functionalized magnetic ion imprinted polymer for fast and selective extraction of trace gold in geological, environmental and biological samples followed by graphite furnace atomic absorption spectrometry detection

    Science.gov (United States)

    Zhao, Bingshan; He, Man; Chen, Beibei; Xu, Hongrun; Hu, Bin

    2018-05-01

    In this study, poly(1-vinylimidazole) functionalized gold ion imprinted polymer coated magnetic nanoparticles (MNPs@PVIM-Au-IIP) were prepared and characterized. The adsorption behaviors of the prepared MNPs@PVIM-Au-IIP toward gold ions (Au(III)) were studied, it was found that MNPs@PVIM-Au-IIP has good selectivity, high adsorption capacity (185.4 mg g-1) and fast adsorption kinetic for Au(III). Based on it, a new method of ion imprinted magnetic solid phase extraction (II-MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the analysis of trace Au(III) in real samples with complicated matrix. Factors affecting MSPE including sample pH, desorption reagent, elution concentration and volume, elution time, sample volume and adsorption time were optimized. With high enrichment factor of 100-fold, the detection limit of the proposed method is 7.9 ng L-1 for Au(III) with the relative standard deviation of 7.4% (c = 50 ng L-1, n = 7). In order to validate the accuracy of the proposed method, the Certified Reference Material of GBW07293 geological sample (platinpalladium ore) was analyzed, and the determined value was in good agreement with the certified value. The proposed II-MSPE-GFAAS method is simple, fast, selective, sensitive and has been successfully applied in the determination of trace Au in ore, sediment, environmental water and human urine samples with satisfactory results.

  11. Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II and Ni(II Ions in Water Samples

    Directory of Open Access Journals (Sweden)

    Saeed Mohammad Sorouraddin

    2017-12-01

    Full Text Available A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II and nickel (II ions in water samples by air-assisted liquid-liquid microextraction (AALLME coupled with graphite furnace atomic absorption spectrometry (GFAAS. In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the absence of disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GFAAS. Several variables that could affect the extraction efficiency were investigated and optimized. Calibration graphs were linear in the range of 6.5-100 ng L-1. Detection limits for Co and Ni were 2.3 ng L-1 and 3 ng L-1, respectively. The accuracy of the developed procedure was checked by analyzing NRCC-SLRS4 Riverine water as a certified reference material. Finally, the proposed method has been successfully applied for the determination of cobalt (II and nickel (II ions in tap, surface and river water samples.

  12. In-situ pre-concentration through repeated sampling and pyrolysis for ultrasensitive determination of thallium in drinking water by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan

    2018-03-01

    In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.

  13. Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Dravecz, Gabriella; Bencs, László; Beke, Dávid; Gali, Adam

    2016-01-15

    The determination of Al contaminant and the main component Si in silicon carbide (SiC) nanocrystals with the size-distribution of 1-8nm dispersed in an aqueous solution was developed using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS). The vaporization/atomization processes were investigated in a transversally heated graphite atomizer by evaporating solution samples of Al and Si preserved in various media (HCl, HNO3). For Si, the best results were obtained by applying a mixture of 5µg Pd plus 5µg Mg, whereas for Al, 10µg Mg (each as nitrate solution) was dispensed with the samples, but the results obtained without modifier were found to be better. This way a maximum pyrolysis temperature of 1200°C for Si and 1300°C for Al could be used, and the optimum (compromise) atomization temperature was 2400°C for both analytes. The Si and Al contents of different sized SiC nanocrystals, dispersed in aqueous solutions, were determined against aqueous (external) calibration standards. The correlation coefficients (R values) of the calibrations were found to be 0.9963 for Si and 0.9991 for Al. The upper limit of the linear calibration range was 2mg/l Si and 0.25mg/l Al. The limit of detection was 3µg/l for Si and 0.5µg/l for Al. The characteristic mass (m0) was calculated to be 389pg Si and 6.4pg Al. The Si and Al content in the solution samples were found to be in the range of 1.0-1.7mg/l and 0.1-0.25mg/l, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Derivative flame atomic absorption spectrometry and its application in trace analysis

    International Nuclear Information System (INIS)

    Sun, H. W.; Li, L. Q.

    2005-01-01

    Flame atomic absorption spectrometry is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for flame atomic absorption spectrometry. The signal models of conventional flame atomic absorption spectrometry are described. The equations of derivative signals are established for flame atomic absorption spectrometry, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dl/dt) is different from the derivative spectrophotometry based on determination of variation rate of signal intensity with wavelength (dl/dhλ). Derivative flame atomic absorption spectrometry has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of derivative flame atomic absorption spectroscopy are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples

  15. Matrix elimination method for the determination of precious metals in ores using electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Salih, Bekir; Celikbiçak, Omür; Döker, Serhat; Doğan, Mehmet

    2007-03-28

    Poly(N-(hydroxymethyl)methacrylamide)-1-allyl-2-thiourea) hydrogels, poly(NHMMA-ATU), were synthesized by gamma radiation using (60)Co gamma source in the ternary mixture of NHMMA-ATU-H(2)O. These hydrogels were used for the specific gold, silver, platinum and palladium recovery, pre-concentration and matrix elimination from the solutions containing trace amounts of precious metal ions. Elimination of inorganic matrices such as different transition and heavy metal ions, and anions was performed by adjusting the solution pH to 0.5 that was the selective adsorption pH of the precious metal ions. Desorption of the precious metal ions was performed by using 0.8 M thiourea in 3M HCl as the most efficient desorbing agent with recovery values more than 95%. In the desorption medium, thiourea effect on the atomic signal was eliminated by selecting proper pyrolysis and atomization temperatures for all precious metal ions. Precision and the accuracy of the results were improved in the graphite furnace-atomic absorption spectrometer (GFAAS) measurements by applying the developed matrix elimination method performing the adsorption at pH 0.5. Pre-concentration factors of the studied precious metal ions were found to be at least 1000-fold. Detection limits of the precious metal ions were found to be less than 10 ng L(-1) of the all studied precious metal ions by using the proposed pre-concentration method. Determination of trace levels of the precious metals in the sea-water, anode slime, geological samples and photographic fixer solutions were performed using GFAAS clearly after applying the adsorption-desorption cycle onto the poly(NHMMA-UTU) hydrogels.

  16. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    Science.gov (United States)

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  17. Determination of trace impurities in titanium dioxide by direct solid sampling electrothermal atomic absorption spectrometry

    Czech Academy of Sciences Publication Activity Database

    Dočekal, Bohumil; Vojtková, B.

    2007-01-01

    Roč. 62, č. 3 (2007), s. 304-308 ISSN 0584-8547. [European Furnace Symposium on Atomic Absorption Spectrometry, Electrothermal Vaporization and Atomization /7./ and Solid Sampling Colloquium with Atomic Spectrometry /12./. St. Petersburg, 02.07.2006-07.07.2006] Institutional research plan: CEZ:AV0Z40310501 Keywords : direct solid sampling * electrothermal atomic absorption spectrometry * trace element analysis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.957, year: 2007

  18. On-line preconcentration of ultra-trace thallium(I in water samples with titanium dioxide nanoparticles and determination by graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Saeid Asadpour

    2016-11-01

    Full Text Available A new method has been developed for the determination of Tl(I based on simultaneous sorption and preconcentration with a microcolumn packed with TiO2 nanoparticle with a high specific surface area prepared by Sonochemical synthesis prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS. The optimum experimental parameters for preconcentration of thallium, such as elution condition, pH, and sample volume and flow rate have been investigated. Tl(I can be quantitatively retained by TiO2 nanoparticles at pH 9.0, then eluted completely with 1.0 mol L−1 HCl. The adsorption capacity of TiO2 nanoparticles for Tl(I was found to be 25 mg g−1. Also detection limit, precision (RSD, n = 8 and enrichment factor for Tl(I were 87 ng L−1, 6.4% and 100, respectively. The method has been applied for the determination of trace amounts of Tl(I in some environmental water samples with satisfactory results.

  19. RAPID AND SENSITIVE DETERMINATION OF PALLADIUM USING HOMOGENEOUS LIQUID-LIQUID MICROEXTRACTION VIA FLOTATION ASSISTANCE FOLLOWED BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Mohammad Rezaee

    2015-05-01

    Full Text Available A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA followed by graphite furnace atomic absorption spectrometry (GFAAS. Ammonium pyrrolidine dithiocarbamate (APDC was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.

  20. Magnetic stirrer induced dispersive ionic-liquid microextraction for the determination of vanadium in water and food samples prior to graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Naeemullah; Kazi, Tasneem Gul; Tuzen, Mustafa

    2015-04-01

    A new dispersive liquid-liquid microextraction, magnetic stirrer induced dispersive ionic-liquid microextraction (MS-IL-DLLME) was developed to quantify the trace level of vanadium in real water and food samples by graphite furnace atomic absorption spectrometry (GFAAS). In this extraction method magnetic stirrer was applied to obtained a dispersive medium of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] in aqueous solution of (real water samples and digested food samples) to increase phase transfer ratio, which significantly enhance the recovery of vanadium - 4-(2-pyridylazo) resorcinol (PAR) chelate. Variables having vital role on desired microextraction methods were optimised to obtain the maximum recovery of study analyte. Under the optimised experimental variables, enhancement factor (EF) and limit of detection (LOD) were achieved to be 125 and 18 ng L(-1), respectively. Validity and accuracy of the desired method was checked by analysis of certified reference materials (SLRS-4 Riverine water and NIST SRM 1515 Apple leaves). The relative standard deviation (RSD) for 10 replicate determinations at 0.5 μg L(-1) of vanadium level was found to be <5.0%. This method was successfully applied to real water and acid digested food samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Speciation and determination of ultra trace amounts of chromium by solidified floating organic drop microextraction (SFODME) and graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Moghadam, Masoud Rohani; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad

    2011-01-01

    Solidified floating organic drop microextraction (SFODME) method in combination with graphite furnace atomic absorption spectrometry (GFAAS) has been used for the determination of chromium species in water and urine samples. 1-undecanol containing 2-thenoyltrifluoroacetone (TTA) was used as a selective chelating agent for the extraction of Cr(III). The total Cr was determined after the reduction of Cr(VI) to Cr(III) with hydroxylamine. The concentration of Cr(VI) was determined from the difference between the concentration of total chromium and the Cr(III). Several variables such as the sample pH, concentration of TTA, salt concentration, extraction time and the sample volume were investigated in detail. Under the optimum conditions, the limit of detection of the proposed method was 0.006 μg l -1 for Cr(III) and the relative standard deviation for six replicate determinations at 0.1 μg l -1 Cr(III) was 5.1%. The proposed method was successfully applied for the determination of chromium species in tap water, well water, mineral water, and urine samples.

  2. Determination of aluminium in groundwater samples by GF-AAS, ICP-AES, ICP-MS and modelling of inorganic aluminium complexes.

    Science.gov (United States)

    Frankowski, Marcin; Zioła-Frankowska, Anetta; Kurzyca, Iwona; Novotný, Karel; Vaculovič, Tomas; Kanický, Viktor; Siepak, Marcin; Siepak, Jerzy

    2011-11-01

    The paper presents the results of aluminium determinations in ground water samples of the Miocene aquifer from the area of the city of Poznań (Poland). The determined aluminium content amounted from aluminium determinations were performed using three analytical techniques: graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The results of aluminium determinations in groundwater samples for particular analytical techniques were compared. The results were used to identify the ascent of ground water from the Mesozoic aquifer to the Miocene aquifer in the area of the fault graben. Using the Mineql+ program, the modelling of the occurrence of aluminium and the following aluminium complexes: hydroxy, with fluorides and sulphates was performed. The paper presents the results of aluminium determinations in ground water using different analytical techniques as well as the chemical modelling in the Mineql+ program, which was performed for the first time and which enabled the identification of aluminium complexes in the investigated samples. The study confirms the occurrence of aluminium hydroxy complexes and aluminium fluoride complexes in the analysed groundwater samples. Despite the dominance of sulphates and organic matter in the sample, major participation of the complexes with these ligands was not stated based on the modelling.

  3. Correction for sample self-absorption in activity determination by gamma spectrometry

    International Nuclear Information System (INIS)

    Galloway, R.B.

    1991-01-01

    Gamma ray spectrometry is a convenient method of determining the activity of the radioactive components in environmental samples. Commonly samples vary in gamma absorption or differ in absorption from the calibration standards available, so that accurate correction for self-absorption in the sample is essential. A versatile correction procedure is described. (orig.)

  4. Atomic absorption spectrometry of the leaves of Newbouldia Laevis (Bignoniaceae)

    International Nuclear Information System (INIS)

    Mohammed, L.; Musa, A.; Isma'il, M. B.; Ahmed, Y. A.; Okunade, I.O.; Garba, M. A.

    2011-01-01

    In this study, fresh leaves samples of Newbouldia laevis, a medicinal plant, popularly known as African Border tree used traditionally for the treatment of a number of diseases, were collected in Dakace, (Lat. 11degree05'N Long. 7degree46'E) Zaria, Kaduna State, North-Central Nigeria, during the wet season (October to November) of 2008. The samples were digested using a tri-acid mixture (HNO 3 , HCIO 4 , and H 2 SO 4 ) in the ratio of 25:4:2 respectively. The concentrations of essential trace elements including magnesium, copper, iron, zinc, and cobalt in the samples were determined by Atomic Absorption Spectrometry (AAS). The results obtained showed that Fe has the highest mean concentration of 8.2481±3.689μg/g; whereas Co has the least mean concentration of 0.111±0.055μg/g. The study also revealed that the mean concentrations of Mg, Cu and Zn exceed the recommended limit set by FAO.

  5. Electrochemical hydride generation atomic absorption spectrometry for determination of cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Arbab-Zavar, M.H. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of)]. E-mail: arbab@um.ac.ir; Chamsaz, M. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of); Youssefi, A. [Pare-Taavous Research Institute, Mashhad (Iran, Islamic Republic of); Aliakbari, M. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of)

    2005-08-01

    An electrolytic hydride generation system for determination of another hydride forming element, cadmium, by catholyte variation electrochemical hydride generation (EcHG) atomic absorption spectrometry is described. A laboratory-made electrolytic cell with lead-tin alloy as cathode material is designed as electrolytic generator of molecular hydride. The influences of several parameters on the analytical signal have been evaluated using a Plackett-Burman experimental design. The significant parameters such as cathode surface area, electrolytic current, carrier gas flow rate and catholyte concentration have been optimized using univariate method. The analytical figures of merit of procedure developed were determined. The calibration curve was linear up to 20 ng ml{sup -1}of cadmium. The concentration detection limit (3{sigma}, n = 8) of 0.2 ng ml{sup -1} and repeatability (relative standard deviation, n = 7) of 3.1% were achieved at 10.0 ng ml{sup -1}. It was shown that interferences from major constituents at high concentrations were significant. The accuracy of method was verified using a real sample (spiked tap water) by standard addition calibration technique. Recovery of 104% was achieved for Cd in the spiked tap water sample.

  6. The role of atomic absorption spectrometry in geochemical exploration

    Science.gov (United States)

    Viets, J.G.; O'Leary, R. M.

    1992-01-01

    In this paper we briefly describe the principles of atomic absorption spectrometry (AAS) and the basic hardware components necessary to make measurements of analyte concentrations. Then we discuss a variety of methods that have been developed for the introduction of analyte atoms into the light path of the spectrophotometer. This section deals with sample digestion, elimination of interferences, and optimum production of ground-state atoms, all critical considerations when choosing an AAS method. Other critical considerations are cost, speed, simplicity, precision, and applicability of the method to the wide range of materials sampled in geochemical exploration. We cannot attempt to review all of the AAS methods developed for geological materials but instead will restrict our discussion to some of those appropriate for geochemical exploration. Our background and familiarity are reflected in the methods we discuss, and we have no doubt overlooked many good methods. Our discussion should therefore be considered a starting point in finding the right method for the problem, rather than the end of the search. Finally, we discuss the future of AAS relative to other instrumental techniques and the promising new directions for AAS in geochemical exploration. ?? 1992.

  7. Arsenic determination in gasoline by hydride generation atomic absorption spectroscopy combined with a factorial experimental design approach

    Energy Technology Data Exchange (ETDEWEB)

    Jemmla Meira Trindade; Aldalea Lopes Marques; Gisele Simone Lopes; Edmar Pereira Marques; Jiujun Zhang [Federal University of Maranhao UFMA, Sao Luis (Brazil). Department of Chemistry

    2006-10-15

    Three locally collected gasoline samples were analyzed for arsenic content using factorial experimental design (FED) with hydride generation atomic absorption spectrometry (HGAAS). Five factors (including the reduction agent flow, the acid flow, the sample flow, the reductor concentration and the acid concentration) in two levels (low and high) were used in this optimization process. In order to design the surface response, five levels of central composite with 15 central points were down-selected. The results were compared with those determined by graphite furnace atomic absorption spectrometry (GFAAS) and a 95% confidence interval (regression procedure) was obtained. The HGAAS and GFAAS measurement sensitivities determined arsenic levels of 0.02 {mu}g L{sup -1} and 0.08 {mu}g L{sup -1}, respectively. 23 refs., 6 figs., 8 tabs.

  8. Atomic absorption spectrometry and other instrumental methods for quantitative measurements of arsenic

    International Nuclear Information System (INIS)

    Brooks, R.R.; Ryan, D.E.; Zhang, H.

    1981-01-01

    Progress in instrumental methods for quantification of arsenic during the past decade is reviewed. Particular emphasis is placed on atomic absorption spectrometry, where major progress has been made in flame methods in conjunction with hydride generation procedures and in electrothermal methods with the graphite furnace. Specific materials in which arsenic is quantified by atomic absorption techniques are also listed. Progress in the application of neutron activation-γ-spectrometry, emission spectrometry, electrometric methods, X-ray procedures and atomic fluorescence spectrometry is also reviewed. The limits of detection and time requirements of all the techniques are compared. (Auth.)

  9. Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.

    Science.gov (United States)

    Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro

    2017-09-01

    Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg -1 ; ICP-MS, 437ngg -1 ) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses. Copyright © 2016 Elsevier GmbH. All rights reserved.

  10. Determination of strontium in rocks by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Tamari, Yuzo; Tsuji, Haruo; Kusaka, Yuzuru

    1984-01-01

    Strontium in silicate rocks was determined by the following procedure. A rock powder sample prepared to pass through a 100-mesh size sieve (0.1--0.5g) was taken in a Teflon beaker, and 6ml of 46% hydrofluoric acid and 1 ml of 70% perchloric acid were added. After being allowed to stand for over one day, the mixture in the beaker was concentrated by heating on a hot plate until white fumes of the perchloric acid appeared. The content in the beaker was transferred to a glass beaker with 2ml of 61% nitric acid and 0.5ml of the perchloric acid, and concentrated until white fumes appeared. Further, 2ml of 20% hydrochloric acid was added and warmed. After cooling, the rock solution was made up to 100ml with water. To a 50-ml stoppered centrifugal tube, a 10-ml portion of the rock solution was transferred, and 1ml of 2% 8-quinolinol solution was added. Then the solution was adjusted to pH 5 with both saturated sodium acetate solution and hydrochloric acid, and made up to 15ml. The decomposed rock sample solution with 20ml of chloroform was shaken for 5min. The decomposed rock sample solution was shaken with 20ml of chloroform for 5min, and then centrifuged at 2500rpm for 5min to separate an aqueous phase from an organic one. After adding 1ml of 2% lanthanum solution into a 10ml portion of the aqueous phase, strontium was determined by atomic absorption spectrometry at 460.7nm. This method was applied to the rock reference materials, JB-1 and JG-1, issued from the Geological Survey of Japan. Analytical values of strontium in the rocks were almost consistent with their certified and recommended values. (author)

  11. DETERMINATION OF TOTAL MERCURY IN FISH TISSUES USING PYROLYSIS ATOMIC ABSORPTION SPECTROMETRY WITH GOLD AMALGAMATION

    Science.gov (United States)

    A simple and rapid procedure for measuring total mercury in fish tissues is evaluated and compared with conventional techniques. Using an automated instrument incorporating combustion, preconcentration by amalgamation with gold, and atomic absorption spectrometry (AAS), mill...

  12. The application of atomic absorption spectrometry to chemical analysis

    International Nuclear Information System (INIS)

    Walsh, A.

    1980-01-01

    YhThe history of the development of atomic absorption methods of elemental analysis is outlined. The theoretical basis of atomic absorption methods is discussed and the principle of modern methods of atomic absorption measurements is described. The advantages, scope and limations of these methods are discussed. Related methods based on the measurement of atomic fluorescence are also described

  13. Quantitative determination of impurities in nuclear grade aluminum by Flame-Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Jat, J.R.; Nayak, A.K.; Balaji Rao, Y.; Ravindra, H.R.

    2013-01-01

    The paper deals with quantitative determination of impurity elements in nuclear grade aluminum, used as fin tubes in research reactors, by Flame-Atomic Absorption Spectrometry (F-AAS). The results have been compared with those obtained by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) method. Experimental conditions used in both the methods are given in the paper. (author)

  14. Determination of diphenylarsinic acid, phenylarsonic acid and inorganic arsenic in drinking water by graphite-furnace atomic-absorption spectrometry after simultaneous separation and preconcentration with solid-phase extraction disks.

    Science.gov (United States)

    Hagiwara, Kenta; Inui, Tetsuo; Koike, Yuya; Nakamura, Toshihiro

    2013-01-01

    A simple method of graphite-furnace atomic-absorption spectrometry (GFAAS) after solid-phase extraction (SPE) was developed for the determination of diphenylarsinic acid (DPAA), phenylarsonic acid (PAA), and inorganic arsenic (iAs) in drinking water. This method involves the simultaneous collection of DPAA, PAA, and iAs using three stacked SPE disks, i.e., an Empore SDB-XD disk (the upper layer), an activated carbon disk (the middle layer), and a Cation-SR disk loaded with Zr and Ca (ZrCa-CED; the lower layer). A 200-mL aqueous sample was adjusted to pH 3 with nitric acid and passed through the SPE disks at a flow rate of 15 mL min(-1), to concentrate DPAA on the SDB-XD disk, PAA on the activated carbon disk, and iAs on the ZrCa-CED. The As compounds were eluted from the disks with 10 mL of ethanol containing 0.5 mol L(-1) ammonia solution for DPAA, 20 mL of 1 mol L(-1) ammonia solution for PAA, and 20 mL of 6 mol L(-1) hydrochloric acid for iAs. The eluates of DPAA, PAA, and iAs were diluted to 20, 25, and 25 mL, respectively, with deionized water, and then analyzed by GFAAS. The detection limits of As (three-times the standard deviation (n = 3) of the blank values) were 0.13 and 0.16 μg L(-1) at enrichment factors of 10 and 8, respectively, using a 200-mL water sample. Spike tests with 2 μg (10 μg L(-1)) of DPAA, PAA, and iAs in 200 mL of tap water and bottled drinking water showed good recoveries (96.1-103.8%).

  15. Speciation of As(III) and As(V) in water samples by graphite furnace atomic absorption spectrometry after solid phase extraction combined with dispersive liquid-liquid microextraction based on the solidification of floating organic drop.

    Science.gov (United States)

    Shamsipur, Mojtaba; Fattahi, Nazir; Assadi, Yaghoub; Sadeghi, Marzieh; Sharafi, Kiomars

    2014-12-01

    A solid phase extraction (SPE) coupled with dispersive liquid-liquid microextraction based on the solidification of floating organic drop (DLLME-SFO) method, using diethyldithiphosphate (DDTP) as a proper chelating agent, has been developed as an ultra preconcentration technique for the determination of inorganic arsenic in water samples prior to graphite furnace atomic absorption spectrometry (GFAAS). Variables affecting the performance of both steps were thoroughly investigated. Under optimized conditions, 100mL of As(ΙΙΙ) solution was first concentrated using a solid phase sorbent. The extract was collected in 2.0 mL of acetone and 60.0 µL of 1-undecanol was added into the collecting solvent. The mixture was then injected rapidly into 5.0 mL of pure water for further DLLME-SFO. Total inorganic As(III, V) was extracted similarly after reduction of As(V) to As(III) with potassium iodide and sodium thiosulfate and As(V) concentration was calculated by difference. A mixture of Pd(NO3)2 and Mg(NO3)2 was used as a chemical modifier in GFAAS. The analytical characteristics of the method were determined. The calibration graph was linear in the rage of 10-100 ng L(-1) with detection limit of 2.5 ng L(-1). Repeatability (intra-day) and reproducibility (inter-day) of method based on seven replicate measurements of 80 ng L(-1) of As(ΙΙΙ) were 6.8% and 7.5%, respectively. The method was successfully applied to speciation of As(III), As(V) and determination of the total amount of As in water samples and in a certified reference material (NIST RSM 1643e). Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Exploiting flow injection and sequential injection for trace metal determinations in conjunction with detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    Despite their excellent analytical chemical capacities, Electrothermal Atomic Absorption Spectrometry (ETAAS) and Inductively Coupled Plasma Mass Spectrometry (ICPMS), nevertheless, often require suitable pretreatment of the sample material in order to obtain the necessary sensitivity...

  17. Study of the Analytical Conditions for the Determination of Cadmium in Coal Fly Ashes by GFAAS with evaluation of several matrix modifiers

    International Nuclear Information System (INIS)

    Rucandio, M.I.; Petit, M.D.

    1998-01-01

    A new method for the determination of cadmium in coal fly ash samples by Graphite Furnace Atomic Absorption Spectrometry (GFAAS) has been developed. Analytical conditions and different instrumental parameters have been optimized. In a first step, several types of matrix modifiers have been tested and a mixture of 2% NH 4 H 2 PO 4 with 0.4%Mg(NO 3 ) 2 in 0.5N HNO 3 has been selected, since it provides the highest sensitivity. In a second step, an optimization of several conditions, using the selected modifier, has been carried out, such as ashing and atomization temperatures, heating rate, etc. The influence of the use of a L' vov platform on the analytical and background signals has been studied, showing a significative decrease on the background signal, being the net absorbance similar to those obtained in absence of the platform. Using the optimal conditions, the direct method with standard samples provides cadmium concentration consistent with those obtained using the standard addition method. (Author) 18 refs

  18. Direct determination of Cd and Pb in human urine by GFAAS with deuterium-lamp background correction using different chemical modifiers

    International Nuclear Information System (INIS)

    Husakova, L.; Baoinova, M.; Sramkova, J.; Cernohorsky, T.

    2007-01-01

    Several authors have contributed to the elaboration of methodology for direct determination of Cd and Pb in urine by graphite furnace atomic absorption spectrometry (GFAAS). In the proposed approaches, Zeeman background correction systems were predominantly used, without paying much attention to the selection of an appropriate chemical modifier. However, systematic studies on eleven recommended and less commonly used modifiers have resulted in optimization of atomization conditions, so that accurate analysis also with the use of D 2 -lamp background correction became possible. This was confirmed by comparative measurements using both background correction systems. For determination of Cd in urine, NH 4 F has been selected resulting in the lowest limit of detection (LOD): 0.07 μg L -1 . NH 4 F promotes efficient atomization at low temperatures and suppresses chloride interference effect. Pd + Sr (nitrate) has been selected as the most adequate modifier for determination of Pb. Its presence raised the maximum tolerable pyrolysis temperature up to 1200 o C, which resulted in the maximum reduction of the background signal and the lowest LOD of 1.5 mg L -1 for Pb (10 μL aliquots of dispensed urine). Applying the above modifiers to the analysis of standards and samples, direct aqueous calibration for accurate analysis of diluted and acidified urine samples became possible. Accuracy of the analysis was verified by the use of commercially available quality control reference materials. (authors)

  19. determination of vanadium in foods by atomic absorption spectrometry

    African Journals Online (AJOL)

    This paper presents an assessment of the level of vanadium in foods (Plantain, Musa spp; Yam, Discorea rotundata; and Maize, Zea mays) from ten popular market places in Lagos metropolis, Nigeria. Total acid leaching digestion method was employed and determination was by Flame Atomic Absorption ...

  20. Determination of boron in natural waters using atomic-absorption spectrometry with electrothermal atomization

    International Nuclear Information System (INIS)

    Usenko, S.I.; Prorok, M.M.

    1992-01-01

    A method of direct determination of boron in natural waters using atomic-absorption spectrometry with electrothermal atomization was developed. Concomitant elements Si, K, Mg, Na, present in natural waters in the concentration of 0.05-100 mg/cv 3 , do not produce effect on the value of boron atomic absorption. Boron determination limit constituted 0.02 mg/cm 3 for 25 ml of solution introduced

  1. Determination of trace impurities in titanium dioxide by direct solid sampling electrothermal atomic absorption spectrometry

    Czech Academy of Sciences Publication Activity Database

    Vojtková, Blanka; Dočekal, Bohumil

    2005-01-01

    Roč. 99, S (2005), s489-s491 ISSN 0009-2770. [Meeting on Chemistry and Life /3./. Brno, 20.09.2005-22.09.2005] Institutional research plan: CEZ:AV0Z40310501 Keywords : solid sampling * electrothermal atomic absorption spectrometry * trace analysis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.445, year: 2005

  2. [Determination of chloride ion in additives of concrete by flame atomic absorption spectrometry].

    Science.gov (United States)

    Xiong, Min; Shan, Yun

    2003-06-01

    Flame atomic absorption spectrometry due to its high sensitivity and selectivity has been widely used for the determination of micro levels of metal elements in various materials. But this method can not be used for the determination of Cl- directly. In this paper the determination of Cl- in additives of concrete by flame atomic absorption spectrometry was studied. Adding superfluous standard solution of Ag+ to the sample solution, the results were obtained by determining the remanent content of Ag+ having reacted with Cl- quantitatively. The acidity of the sample solution and the precision were studied. The standard rate of recovery obtained was in the range of 96%-104%. By the determination of actual samples it was proved that the method features simple sample preparation, fast determination, and little interference, especially for those samples which contain micro levels of Cl-. The procedure is as follows: weight 0.05-2 g of sample, dissolve it in water and adjust the acidity with nitric acid, add proper standard solution of Ag+, and after 2 h, measure the remanent Ag+ content by atomic absorption spectrometry. A GBC902 atomic absorption spectrometry was employed.

  3. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry-Performance evaluation for selenium

    Czech Academy of Sciences Publication Activity Database

    Duben, Ondřej; Boušek, J.; Dědina, Jiří; Kratzer, Jan

    2015-01-01

    Roč. 111, SEP (2015), s. 57-63 ISSN 0584-8547 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation-atomic absorption spectrometry * selenium Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  4. Rapid accurate analysis of metal (oxide)-on-silica catalysts by atomic absorption spectrometry

    NARCIS (Netherlands)

    Jütte, B.A.H.G.; Heikamp, A.; Agterdenbos, J.

    1979-01-01

    The catalysts, which contain 10–60% copper, chromium, nickel and silicon, are decomposed in sealed Teflon-lined vessels and analyzed by atomic absorption spectrometry. Matrix matching and bracketing standards are applied. The RSD of a single determination is about 1% for all components.

  5. Direct microcomputer controlled determination of zinc in human serum by flow injection atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Nielsen, Bent; Jensen, Arne

    1986-01-01

    A procedure is described for the direct determination of zinc in human serum by fully automated, microcomputer controlled flow injection atomic absorption spectrometry (Fl-AAS). The Fl system is pumpless, using the negative pressure created by the nebuliser. It only consists of a three-way valve...

  6. COMPREHENSIVE ANALYSIS OF BIOLOGICALLY RELEVANT ARSENICALS BY PH-SELECTIVE HYDRIDE GENERATION-ATOMIC ABSORPTION SPECTROMETRY

    Science.gov (United States)

    A method based on pH-selective generation and separation of arsines is commonly used for analysis of inorganic, methylated, and dimethylated trivalent and pentavalent arsenicals by hydride generation-atomic absorption spectrometry (HG-AAS). We have optimized this method to pe...

  7. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry-Performance evaluation for selenium

    Czech Academy of Sciences Publication Activity Database

    Duben, Ondřej; Boušek, J.; Dědina, Jiří; Kratzer, Jan

    2015-01-01

    Roč. 111, SEP (2015), s. 57-63 ISSN 0584-8547 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation- atomic absorption spectrometry * selenium Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  8. In-situ trapping of bismuthine in externally heated quartz tube atomizers for atomic absorption spectrometry

    Czech Academy of Sciences Publication Activity Database

    Kratzer, Jan; Dědina, Jiří

    2006-01-01

    Roč. 21, č. 2 (2006), s. 208-210 ISSN 0267-9477 R&D Projects: GA AV ČR IAA400310507 Institutional research plan: CEZ:AV0Z40310501 Keywords : bismuth ine preconcentration * quartz surface * hydride generation atomic absorption spectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.630, year: 2006

  9. Determination of Cd in urine by cloud point extraction-tungsten coil atomic absorption spectrometry.

    Science.gov (United States)

    Donati, George L; Pharr, Kathryn E; Calloway, Clifton P; Nóbrega, Joaquim A; Jones, Bradley T

    2008-09-15

    Cadmium concentrations in human urine are typically at or below the 1 microgL(-1) level, so only a handful of techniques may be appropriate for this application. These include sophisticated methods such as graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. While tungsten coil atomic absorption spectrometry is a simpler and less expensive technique, its practical detection limits often prohibit the detection of Cd in normal urine samples. In addition, the nature of the urine matrix often necessitates accurate background correction techniques, which would add expense and complexity to the tungsten coil instrument. This manuscript describes a cloud point extraction method that reduces matrix interference while preconcentrating Cd by a factor of 15. Ammonium pyrrolidinedithiocarbamate and Triton X-114 are used as complexing agent and surfactant, respectively, in the extraction procedure. Triton X-114 forms an extractant coacervate surfactant-rich phase that is denser than water, so the aqueous supernatant is easily removed leaving the metal-containing surfactant layer intact. A 25 microL aliquot of this preconcentrated sample is placed directly onto the tungsten coil for analysis. The cloud point extraction procedure allows for simple background correction based either on the measurement of absorption at a nearby wavelength, or measurement of absorption at a time in the atomization step immediately prior to the onset of the Cd signal. Seven human urine samples are analyzed by this technique and the results are compared to those found by the inductively coupled plasma mass spectrometry analysis of the same samples performed at a different institution. The limit of detection for Cd in urine is 5 ngL(-1) for cloud point extraction tungsten coil atomic absorption spectrometry. The accuracy of the method is determined with a standard reference material (toxic metals in freeze-dried urine) and the determined values agree with

  10. Cobalt internal standard for Ni to assist the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis.

    Science.gov (United States)

    de Babos, Diego Victor; Bechlin, Marcos André; Barros, Ariane Isis; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta; de Oliveira, Silvana Ruella

    2016-05-15

    A new method is proposed for the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS), employing direct solid sample analysis (DSS) and internal standardization (IS). Cobalt was used as internal standard to minimize matrix effects during Ni determinations, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9937. The performance of the method was checked by analysis of six plant certified reference materials, and the results for Mo and Ni were in agreement with the certified values (95% confidence level, t-test). Analysis was made of different types of plant materials used as renewable sources of energy, including sugarcane leaves, banana tree fiber, soybean straw, coffee pods, orange bagasse, peanut hulls, and sugarcane bagasse. The concentrations found for Mo and Ni ranged from 0.08 to 0.63 ng mg(-1) and from 0.41 to 6.92 ng mg(-1), respectively. Precision (RSD) varied from 2.1% to 11% for Mo and from 3.7% to 10% for Ni. Limits of quantification of 0.055 and 0.074 ng were obtained for Mo and Ni, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Determination of Ultra-trace Rhodium in Water Samples by Graphite Furnace Atomic Absorption Spectrometry after Cloud Point Extraction Using 2-(5-Iodo-2-Pyridylazo)-5-Dimethylaminoaniline as a Chelating Agent.

    Science.gov (United States)

    Han, Quan; Huo, Yanyan; Wu, Jiangyan; He, Yaping; Yang, Xiaohui; Yang, Longhu

    2017-03-24

    A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1-6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% ( c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results.

  12. Study on solid phase extraction and graphite furnace atomic absorption spectrometry for the determination of nickel, silver, cobalt, copper, cadmium and lead with MCI GEL CHP 20Y as sorbent

    International Nuclear Information System (INIS)

    Yang Guangyu; Fen Weibo; Lei Chun; Xiao Weilie; Sun Handong

    2009-01-01

    A solid phase extraction and graphite furnace atomic absorption spectrometry (GFAAS) for the determination of nickel, silver, cobalt, copper, cadmium and lead with MCI GEL CHP 20Y as sorbent was studied. Trace amounts of chromium, nickel, silver, cobalt, copper, cadmium and lead were reacted with 2-(2-quinolinil-azo)-4-methyl-1,3-dihydroxidobenzene (QAMDHB) followed by adsorption onto MCI GEL CHP 20Y solid phase extraction column, and 1.0 mol L -1 HNO 3 was used as eluent. The metal ions in 300 mL solution can be concentrated to 1.0 mL, representing an enrichment factor of 300 was achieved. The recoveries of analytes at pH 8.0 with 1.0 g of resin were greater than 95% without interference from alkaline, earth alkaline and some metal ions. When detected with graphite furnace atomic absorption spectrometry, the detection limits in the original samples were 1.4 ng L -1 for Cr(III), 1.0 ng L -1 for Ni(II), 0.85 ng L -1 for Ag(I), 1.2 ng L -1 for Co(II), 1.0 ng L -1 for Cu(II), 1.2 ng L -1 for Cd(II) and 1.3 ng L -1 for Pb(II). The validation of the procedure was performed by the analysis of the certified standard reference materials, and the presented procedure was applied to the determination of analytes in biological, water and soil samples with good results (recoveries range from 89 to 104%, and R.S.D.% lower than 3.2%. The results agreed with the standard value or reference method)

  13. Direct determination of selenoproteins in polyvinylidene difluoride membranes by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Sidenius, U; Gammelgaard, Bente

    2000-01-01

    A method for the direct determination of selenoproteins in plastic membranes after protein separation by gel electrophoresis was developed. Quantification was based on the determination of the selenium content of the proteins by electrothermal atomic absorption spectrometry (ET-AAS) after manual...... were excised and chemical modifier was added on top of the excised membrane prior to atomic absorption measurement. Acceptable linearity was achieved in the range 2-10 ng Se, corresponding to selenium concentrations close to 1 mg/L, when aqueous solutions of selenomethionine standard as well...

  14. Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: a comparative study.

    Science.gov (United States)

    Cabon, J Y; Giamarchi, P; Le Bihan, A

    2010-04-07

    Two methods available for direct determination of total Fe in seawater at low concentration level have been examined: electrothermal atomization atomic absorption spectrometry (ETAAS) and electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS). In a first part, we have optimized experimental conditions of ETAAS (electrothermal program, matrix chemical modification) for the determination of Fe in seawater by minimizing the chemical interference effects and the magnitude of the simultaneous background absorption signal. By using the best experimental conditions, a detection limit of 80 ng L(-1) (20 microL, 3sigma) for total Fe concentration was obtained by ETAAS. Using similar experimental conditions (electrothermal program, chemical modification), we have optimized experimental conditions for the determination of Fe by LEAFS. The selected experimental conditions for ETA-LEAFS: excitation wavelength (296.69 nm), noise attenuation and adequate background correction led to a detection limit (3sigma) of 3 ng L(-1) (i.e. 54 pM) for total Fe concentration with the use a 20 microL seawater sample. For the two methods, concentration values obtained for the analysis of Fe in a NASS-5 (0.2 microg L(-1)) seawater sample were in good agreement with the certified values. Copyright 2010 Elsevier B.V. All rights reserved.

  15. Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: A comparative study

    International Nuclear Information System (INIS)

    Cabon, J.Y.; Giamarchi, P.; Le Bihan, A.

    2010-01-01

    Two methods available for direct determination of total Fe in seawater at low concentration level have been examined: electrothermal atomization atomic absorption spectrometry (ETAAS) and electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS). In a first part, we have optimized experimental conditions of ETAAS (electrothermal program, matrix chemical modification) for the determination of Fe in seawater by minimizing the chemical interference effects and the magnitude of the simultaneous background absorption signal. By using the best experimental conditions, a detection limit of 80 ng L -1 (20 μL, 3σ) for total Fe concentration was obtained by ETAAS. Using similar experimental conditions (electrothermal program, chemical modification), we have optimized experimental conditions for the determination of Fe by LEAFS. The selected experimental conditions for ETA-LEAFS: excitation wavelength (296.69 nm), noise attenuation and adequate background correction led to a detection limit (3σ) of 3 ng L -1 (i.e. 54 pM) for total Fe concentration with the use a 20 μL seawater sample. For the two methods, concentration values obtained for the analysis of Fe in a NASS-5 (0.2 μg L -1 ) seawater sample were in good agreement with the certified values.

  16. Determination of five trace elements in leaves in Nanfang sweet orange by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Li Fangqing

    2006-01-01

    The five trace elements of copper, zinc, manganese, iron and cobalt in leaves of Nanfang sweet orange are determined by flame atomic absorption spectrometry. The technique is simple, precise and sensitive. The effect of the type of digesting solution (mixed acid), the ratio of mixed acid, the volume of digesting solution and the time of digesting are investigated in details. The results show that leaves of Nanfang sweet orange contain higher amount of iron and zinc. (authors)

  17. Gold volatile species atomization and preconcentration in quartz devices for atomic absorption spectrometry

    Czech Academy of Sciences Publication Activity Database

    Arslan, Y.; Musil, Stanislav; Matoušek, Tomáš; Kratzer, Jan; Dědina, Jiří

    103-104, JAN-FEB (2015), s. 155-163 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : gold * volatile species generation * quartz atomizers * atomic absorption spectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  18. Evaluation of a method for the determination of chromium in urine by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Garcia, M.; Sardinas, O.; Castaneda, I.; Sanchez, R.

    1990-01-01

    A method for the determination of chromium in urine by atomic absorption spectrometry, using electrothermic atomization with pyrolytic graphite tubes, is proposed. The determinations are performed by standard addition. The method is applicable to biologic monitoring of populations with different degrees of exposition. It is also used in the analysis of chromium in sediments. Results of chromium in urine of a population group non-exposed to the metal are presented. 11 refs

  19. Determination of diethyllead in the urine by flameless atomic absorption spectrometry.

    OpenAIRE

    Turlakiewicz, Z; Jakubowski, M; Chmielnicka, J

    1985-01-01

    A method for the determination of diethyllead in urine by flameless atomic absorption spectrometry after chelation with glyoxal-bis (2-hydroxyanil) and extraction of the formed complex with methyl isobutyl ketone is described. The method is specific in relation to both triethyllead and inorganic lead. The limit of detection was 3.2 micrograms Pb/l and the relative standard deviation in the concentration range 20-100 micrograms Pb/l was 0.076.

  20. Analysis of Dithiocarbamate Fungicides in Vegetable Matrices Using HPLC-UV Followed by Atomic Absorption Spectrometry.

    Science.gov (United States)

    Al-Alam, Josephine; Bom, Laura; Chbani, Asma; Fajloun, Ziad; Millet, Maurice

    2017-04-01

    A simple method combining ion-pair methylation, high-performance liquid chromatography (HPLC) analysis with detection at 272 nm and atomic absorption spectrometry was developed in order to determine 10 dithiocarbamate fungicides (Dazomet, Metam-sodium, Ferbam, Ziram, Zineb, Maneb, Mancozeb, Metiram, Nabam and Propineb) and distinguish ethylenbisdithiocarbamates (EBDTCs) Zineb, Maneb and Mancozeb in diverse matrices. This method associates reverse phase analysis by HPLC analysis with detection at 272 nm, with atomic absorption spectrometry in order to distinguish, with the same extraction protocol, Maneb, Mancozeb and Zineb. The limits of detection (0.4, 0.8, 0.5, 1.25 and 1.97) and quantification (1.18, 2.5, 1.52, 4.2 and 6.52) calculated in injected nanogram, respectively, for Dazomet, Metam-Na, dimethyldithiocarbamates (DMDTCs), EBDTCs and propylenebisdithiocarbamates (PBDTCs) justify the sensitivity of the method used. The coefficients of determination R2 were 0.9985, 0.9978, 0.9949, 0.988 and 0.9794, respectively, for Dazomet, Metam-Na, DMDTCs, EBDTCs and PBDTCs, and the recovery from fortified apple and leek samples was above 90%. Results obtained with the atomic absorption method in comparison with spectrophotometric analysis focus on the importance of the atomic absorption as a complementary specific method for the distinction between different EBDTCs fungicides. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Comparison of electrothermal atomization diode laser Zeeman- and wavelength-modulated atomic absorption and coherent forward scattering spectrometry

    International Nuclear Information System (INIS)

    Blecker, Carlo R.; Hermann, Gerd M.

    2009-01-01

    Atomic absorption and coherent forward scattering spectrometry by using a near-infrared diode laser with and without Zeeman and wavelength modulation were carried out with graphite furnace electrothermal atomization. Analytical curves and limits of detection were compared. The magnetic field was modulated with 50 Hz, and the wavelength of the diode laser with 10 kHz. Coherent forward scattering was measured with crossed and slightly uncrossed polarizers. The results show that the detection limits of atomic absorption spectrometry are roughly the same as those of coherent forward scattering spectrometry with crossed polarizers. According to the theory with bright flicker noise limited laser sources the detection limits and linear ranges obtained with coherent forward scattering spectrometry with slightly uncrossed polarizers are significantly better than those obtained with crossed polarizers and with atomic absorption spectrometry. This is due to the fact that employing approaches of polarization spectroscopy reduce laser intensity fluctuations to their signal carried fractions

  2. Graphene oxide-TiO2 composite solid phase extraction combined with graphite furnace atomic absorption spectrometry for the speciation of inorganic selenium in water samples.

    Science.gov (United States)

    Zhang, Yanan; Chen, Beibei; Wu, Shaowei; He, Man; Hu, Bin

    2016-07-01

    In this paper, a method of graphene oxide (GO)-TiO2 composite solid phase extraction followed by graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the speciation of inorganic selenium in environmental waters. The adsorption behavior of inorganic Se(IV) and Se(VI) on the GO-TiO2(1:1) composite was investigated. It was found that Se(IV) was quantitatively retained on the GO-TiO2 composites within a wide pH range of 0.5-10, while Se(VI) was quantitatively adsorbed on GO-TiO2(1:1) composite at pH 0.5-2, and no obvious adsorption of Se(VI) within the pH range of 4-10 was found. By selecting pH 6.0, Se(IV) could be easily determined. After reduction of Se(VI), total Se was determined by the proposed method, and Se(VI) was calculated as the difference between the total Se and Se(IV). The factors affecting the separation/preconcentration of Se(IV) and Se(VI) were studied. Under the optimum conditions, the isothermal adsorption of Se(IV) on the GO-TiO2(1:1) composite fitted Langmuir model; a linear range over 0.1-12ngmL(-1) was obtained. The limit of detection (LOD) and precision of the method for Se(IV) was 0.04ngmL(-1) and 9.4% (cSe(IV)=0.5ngmL(-1), n=7), respectively. In order to verify the accuracy of the method, a standard water sample (GSBZ50031-94) was analyzed, and the determined value was in a good agreement to the certified value. The established method was applied to inorganic Se speciation in environmental water samples and the recovery of 87.4-102% was obtained for the spiked samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Lead concentrations and isotope ratios in street dust determined by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Nageotte, S M; Day, J P

    1998-01-01

    A major source of environmental lead, particularly in urban areas, has been from the combustion of leaded petrol. Street dust has previously been used to assess urban lead contamination, and the dust itself can also be a potential source of lead ingestion, particularly to children. The progressive reduction of lead in petrol, in recent years, would be expected to have been reflected in a reduction of lead in urban dust. We have tested this hypothesis by repeating an earlier survey of Manchester street dust and carrying out a comparable survey in Paris. Samples were collected from streets and parks, lead was extracted by digestion with concentrated nitric acid and determined by electrothermal atomic absorption spectrometry. Lead isotope ratios were measured by inductively coupled plasma mass spectrometry. Results for Manchester show that lead concentrations have fallen by about 40% (street dust averages, 941 micrograms g-1 (ppm) in 1975 down to 569 ppm in 1997). In Paris, the lead levels in street dust are much higher and significant differences were observed between types of street (not seen in Manchester). Additionally, lead levels in parks were much lower than in Manchester. Samples collected under the Eiffel Tower had very high concentrations and lead isotope ratios showed that this was unlikely to be fallout from motor vehicles but could be due to the paint used on the tower. Isotope ratios measurements also revealed that lead additives used in France and the UK come from different sources.

  4. Determination of mercury in sewage sludge by direct slurry sampling graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Baralkiewicz, Danuta; Gramowska, Hanka; Kozka, MaIgorzata; Kanecka, Anetta

    2005-01-01

    Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method was elaborated to the determination of Hg in sewage sludge samples with the use of KMnO 4 +Pd modifier. The minimum sample amount required for slurry preparation with respect to sample homogeneity was evaluated by weighting masses between 3 and 30 mg directly into the autosampler cups. Validation of the proposed method was performed with the use of Certified Reference Materials of sewage sludge, CRM 007-040 and CRM 144R. Two sewage sludge samples from Poznan (Poland) city were analysed using the present direct method and a method with sample digestion, resulting in no difference within statistical error

  5. Measurements of sulfur compounds in CO 2 by diode laser atomic absorption spectrometry

    Science.gov (United States)

    Franzke, J.; Stancu, D. G.; Niemax, K.

    2003-07-01

    Two simple methods for the analysis of the total concentration of sulfur in CO 2 by diode laser atomic absorption spectrometry of excited, metastable sulfur atoms in a direct current discharge are presented. In the first method, the CO 2 sample gas is mixed with the plasma gas (Ar or He) while the second is based on reproducible measurements of the sulfur released from the walls in a helium discharge after being deposited as a result of operating the discharge in pure CO 2 sample gas. The detection limits obtained satisfy the requirements for the control of sulfur compounds in CO 2 used in the food and beverage industry.

  6. Determination of lead in high-purity silver. Comparison between photon activation and atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Loos-Neskovic, C.; Fedoroff, M.; Revel, G.

    1978-01-01

    A chemical separation based on the fixation of silver on nickel ferrocyanide was studied. It was applied to the determination of lead in silver by photon-activation or atomic absorption spectrometry. The first method gave a detection limit of 0.1 μg. The second one could not be applied for concentration less than 50 μg/g, owing to loss by adsorption. Analytical results showed that lead is one of the major metallic impurity in high purity silver. (author)

  7. [Determination of mercury in Boletus impolitus by flow injection-atomic absorption spectrometry].

    Science.gov (United States)

    Li, Tao; Wang, Yuan-Zhong

    2008-04-01

    Various test conditions and effect factors for the determination of mercury by flow injection-atomic absorption spectrometry were discussed, and a method for the determination of mercury in Boletus impolitus has been developed. The linear range for mercury is 0-60 microg x L(-1). The relative standard deviation is less than 3.0%, and the recovery is 96%-107%. This method is simple, rapid and has been applied to the determination of mercury in Boletus impolitus samples with satisfactory results.

  8. An indirect method for determining phosphorus in aluminium alloys by atomic-absorption spectrometry.

    Science.gov (United States)

    Bernal, J L; Del Nozal, M A; Deban, L; Aller, A J

    1981-07-01

    An indirect method is described for the determination of phosphorus in aluminium alloys. Ammonium molybdate is added to a solution of the aluminium alloy and the molybdophosphoric acid formed is selectively extracted into n-butyl acetate. The twelve molybdenum atoms associated with each phosphate ion are determined by direct atomic-absorption spectrometry with the n-butyl acetate phase in a nitrous oxide-acetylene flame, with measurement at 313.2 nm. The most suitable conditions have been established and the effect of other ions has been studied.

  9. Exploiting flow Injection and sequential injection schemes for trace metal determinations by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    Determination of low or trace-level amounts of metals by electrothermal atomic absorption spectrometry (ETAAS) often requires the use of suitable preconcentration and/or separation procedures in order to attain the necessary sensitivity and selectivity. Such schemes are advantageously executed...... by superior performance and versatility. In fact, two approaches are conceivable: The analyte-loaded ion-exchange beads might either be transported directly into the graphite tube where they are pyrolized and the measurand is atomized and quantified; or the loaded beads can be eluted and the eluate forwarded...

  10. Flow Injection and Atomic Absorption Spectrometry - An Effective and Attractive Analytical Chemical Combination

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Nielsen, Steffen

    1998-01-01

    One of the advantages of the flow injection (FI) concept is that it is compatible with virtually all detection techniques. Being a versatile vehicle for enhancing the performance of the individual detection devices, the most spectacular results have possibly been obtained in conjunction with atomic...... absorption spectrometry (AAS). Initially with flame-AAS (FAAS) procedures, later for hydride generation (HG) techniques, and most recently in combination with electrothermal AAS (ETAAS). The common denominator for all these procedures is the inherently precise and strictly reproducible timing that the sample...

  11. Direct determination of selenoproteins in polyvinylidene difluoride membranes by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Sidenius, U; Gammelgaard, Bente

    2000-01-01

    A method for the direct determination of selenoproteins in plastic membranes after protein separation by gel electrophoresis was developed. Quantification was based on the determination of the selenium content of the proteins by electrothermal atomic absorption spectrometry (ET-AAS) after manual...... introduction of membrane pieces into the graphite furnace. The proteins were separated by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and subsequently transferred to a polyvinylidene difluoride (PVDF) membrane by semi-dry electroblotting. After staining the membrane, the protein bands...... were excised and chemical modifier was added on top of the excised membrane prior to atomic absorption measurement. Acceptable linearity was achieved in the range 2-10 ng Se, corresponding to selenium concentrations close to 1 mg/L, when aqueous solutions of selenomethionine standard as well...

  12. Atomic absorption spectrometry using tungsten and molybdenum tubes as metal atomizer

    International Nuclear Information System (INIS)

    Kaneco, Satoshi; Katsumata, Hideyuki; Ohta, Kiyohisa; Suzuki, Tohru

    2007-01-01

    We have developed a metal tube atomizer for the electrothermal atomization atomic absorption spectrometry (ETA-AAS). Tungsten, molybdenum, platinum tube atomizers were used as the metal atomizer for ETA-AAS. The atomization characteristics of various metals using these metal tube atomizers were investigated. The effects of heating rate of atomizer, atomization temperature, pyrolysis temperature, argon purge gas flow rate and hydrogen addition on the atomic absorption signal were investigated for the evaluation of atomization characteristics. Moreover, ETA-AAS with metal tube atomizer has been combined with the slurry-sampling techniques. Ultrasonic slurry-sampling ETA-AAS with metal tube atomizer were effective for the determination of trace metal elements in biological materials, calcium drug samples, herbal medicine samples, vegetable samples and fish samples. Furthermore, a preconcentration method of trace metals involving adsorption on a metal wire has been applied to ETA-AAS with metal tube atomizer. (author)

  13. High-resolution continuum-source atomic absorption spectrometry: what can we expect?

    Directory of Open Access Journals (Sweden)

    Welz Bernhard

    2003-01-01

    Full Text Available A new instrumental concept has been developed for atomic absorption spectrometry (AAS, using a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator and a CCD array detector, providing a resolution of ~2 pm per pixel. Among the major advantages of the system are: i an improved signal-to-noise ratio because of the high intensity of the radiation source, resulting in improved photometric precision and detection limits; ii for the same reason, there are no more 'weak' lines, i.e. secondary lines can be used without compromises; iii new elements might be determined, for which no radiation source has been available; iv the entire spectral environment around the analytical line becomes 'visible', giving a lot more information than current AAS instruments; v the CCD array detector allows a truly simultaneous background correction close to the analytical line; vi the software is capable of storing reference spectra, e.g. of a molecular absorption with rotational fine structure, and of subtracting such spectra from the spectra recorded for a sample, using a least squares algorithm; vii although not yet realized, the system makes possible a truly simultaneous multi-element AAS measurement when an appropriate two-dimensional detector is used, as is already common practice in optical emission spectrometry; vii preliminary experiments have indicated that the instrumental concept could result in a more rugged analytical performance in the determination of trace elements in complex matrices.

  14. Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lepri, Fabio G.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Borges, Daniel L.G.; Welz, Bernhard; Heitmann, Uwe

    2006-01-01

    Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, L'vov and Khartsyzov proposed to use the non-resonance doublet at 213.5 / 213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 deg. C . The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the

  15. Implementation of suitable flow injection/sequential-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    2002-01-01

    Various preconditioning procedures encomprising appropriate separation/preconcentration schemes in order to obtain optimal sensitivity and selectivity characteristics when using electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS...

  16. Trace elements determination in high salinity petroleum produced formation water by high-resolution continuum source graphite furnace atomic absorption spectrometry after matrix separation using Chelex-100 Registered-Sign resin

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Aline Soares [Departamento de Geoquimica, Universidade Federal Fluminense, Outeiro Sao Joao Batista s/n, Centro, Niteroi/RJ, 24020-150 (Brazil); Departamento de Quimica Analitica, Universidade Federal do Rio de Janeiro Av. Athos da Silveira Ramos 149, Centro de Tecnologia, Bloco A, Cidade Universitaria, Rio de Janeiro/RJ, 21941-909 (Brazil); Santelli, Ricardo Erthal, E-mail: santelli@iq.ufrj.br [Departamento de Geoquimica, Universidade Federal Fluminense, Outeiro Sao Joao Batista s/n, Centro, Niteroi/RJ, 24020-150 (Brazil); Departamento de Quimica Analitica, Universidade Federal do Rio de Janeiro Av. Athos da Silveira Ramos 149, Centro de Tecnologia, Bloco A, Cidade Universitaria, Rio de Janeiro/RJ, 21941-909 (Brazil)

    2012-05-15

    This study describes a procedure used for the determination of trace metals (Co, Cu, Mn, Ni and Pb) in high salinity petroleum produced formation water (PFW) employing high-resolution continuum source graphite furnace atomic absorption spectrometry for detection and Chelex-100 Registered-Sign resin for matrix elimination and analytes preconcentration. Using 15.0 mL of PFW for the separation/preconcentration, detection limits of 0.006, 0.07, 0.03, 0.08 and 0.02 {mu}g L{sup -1} were obtained for Co, Cu, Mn, Ni and Pb, respectively. The accuracy of the proposed method was evaluated by analyzing three seawater certified reference materials and by recovery tests, and the data indicate that the methodology can be successfully applied to this kind of samples. The precision values, expressed as relative standard deviation (% RSD, n = 10) for 2.0 {mu}g L{sup -1}, were found to be 3.5, 4.0, 9.0, 5.3 and 5.9 for Co, Cu, Mn, Ni and Pb, respectively. The proposed procedure was applied for the determination of these metals in medium and high salinity PFW samples obtained from Brazilian offshore petroleum exploration platforms. - Highlights: Black-Right-Pointing-Pointer Petroleum-produced formation water were analyzed for Co, Cu, Mn, Ni and Pb determination. Black-Right-Pointing-Pointer In batch analyte preconcentration/matrix separation using Chelex-100 Registered-Sign was used. Black-Right-Pointing-Pointer Detection limits between 0.006 and 0.08 {mu}g L{sup -1} were found by using HR-CS-GFAAS. Black-Right-Pointing-Pointer Trace elements characterization is possible using the developed method. Black-Right-Pointing-Pointer Maximum trace element concentrations found could support future Brazilian directives.

  17. The determination of magnesium in simulated PWR coolant by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Gatford, C.; Torrance, K.

    1988-06-01

    The determination of magnesium in simulated PWR coolant has been investigated by graphite furnace atomic absorption spectrometry with atomization from a L'vov platform. The presence of boric acid in the coolant suppresses the magnesium absorption to such an extent that removal of the boron is necessary and three variations of a methyl borate volatilization technique for the in situ removal of boron from the sample platform were investigated. This work has shown that dilution of the sample with an equal volume of acidified methanol and volatilization of the methyl borate was adequate for the determination of magnesium in coolant samples containing up to 2000 mg 1 -1 of boron. In simulated coolant samples containing 25 and 4 μg 1 -1 of magnesium, positive biases of about 2 and 0.5 μg 1 -1 were measured and these errors were considered to be due to contamination. The limit of detection in the presence of 100 and 2000 mg 1 -1 boron were 0.14 and 0.93 μg 1 -1 respectively. These performance characteristics suggest the method is completely acceptable for monitoring the chemical purity of PWR coolant and associated waters containing boric acid. If, however, more precise analyses were to be required for research purposes then any significant improvement in the above figures would require increased purity of reagents, clean-room conditions to reduce contamination and a more versatile atomic absorption spectrophotometer. (author)

  18. Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Dessuy, Morgana B.; Vale, Maria Goreti R.; Lepri, Fabio G.; Welz, Bernhard; Heitmann, Uwe

    2007-01-01

    The atomization of phosphorus in electrothermal atomic absorption spectrometry has been investigated using a high-resolution continuum source atomic absorption spectrometer and atomization from a graphite platform as well as from a tantalum boat inserted in a graphite tube. A two-step atomization mechanism is proposed for phosphorus, where the first step is a thermal dissociation, resulting in a fast atomization signal early in the atomization stage, and the second step is a slow release of phosphorus atoms from the graphite tube surface following the adsorption of molecular phosphorus at active sites of the graphite surface. Depending on experimental conditions only one of the mechanisms or both might be active. In the absence of a modifier and with atomization from a graphite or tantalum platform the second mechanism appears to be dominant, whereas in the presence of sodium fluoride as a modifier both mechanisms are observed. Intercalation of phosphorus into the graphite platform in the condensed phase has also been observed; this phosphorus, however, appears to be permanently trapped in the structure of the graphite and does not contribute to the absorption signal

  19. Noise-Immune Cavity-Enhanced Optical Heterodyne Molecular Spectrometry Modelling Under Saturated Absorption

    Science.gov (United States)

    Dupré, Patrick

    2015-06-01

    The Noise-Immune Cavity-Enhanced Optical Heterodyne Molecular Spectrometry (NICE-OHMS) is a modern technique renowned for its ultimate sensitivity, because it combines long equivalent absorption length provided by a high finesse cavity, and a detection theoretically limited by the sole photon-shot-noise. One fallout of the high finesse is the possibility to accumulating strong intracavity electromagnetic fields (EMF). Under this condition, molecular transitions can be easy saturated giving rise to the usual Lamb dips (or hole burning). However, the unusual shape of the basically trichromatic EMF (due to the RF lateral sidebands) induces nonlinear couplings, i.e., new crossover transitions. An analytical methodology will be presented to calculate spectra provided by NICE-OHMS experiments. It is based on the solutions of the equations of motion of an open two-blocked-level system performed in the frequency-domain (optically thin medium). Knowing the transition dipole moment, the NICE-OHMS signals (``absorption-like'' and ``dispersion-like'') can be simulated by integration over the Doppler shifts and by paying attention to the molecular Zeeman sublevels and to the EMF polarization The approach has been validated by discussion experimental data obtained on two transitions of {C2H2} in the near-infrared under moderated saturation. One of the applications of the saturated absorption is to be able to simultaneously determine the transition intensity and the density number while only one these 2 quantities can only be assessed in nonlinear absorption. J. Opt. Soc. Am. B 32, 838 (2015) Optics Express 16, 14689 (2008)

  20. Determination of vanadium in mussels by electrothermal atomic absorption spectrometry without chemical modifiers

    Energy Technology Data Exchange (ETDEWEB)

    Saavedra, Y.; Fernandez, P. [Centro de Control do Medio Marino, Peirao de Vilaxoan s/n, Vilagarcia de Arousa, 36611 Pontevedra (Spain); Gonzalez, A. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Quimica, 15706, Santiago de Compostela (Spain)

    2004-05-01

    A method was developed for the quantitative determination of total vanadium concentration in mussels via electrothermal atomic absorption spectrometry (ETAAS). After the microwave digestion of the samples, a program using temperatures of 1600 C and 2600 C for ashing and atomization respectively, without any matrix modifiers, allowed us to obtain results that were satisfactory since they agreed closely with certified reference material values. The detection limit was 0.03 mg kg{sup -1} (dry weight), indicating that the method is suitable for the analysis of mussel samples. This determination was compared with matrix modifiers that have been reported previously. The method was applied to various cultivated and wild mussels from the Galician coast, yielding levels below 1 mg kg{sup -1} (wet weight). (orig.)

  1. Determination of microquantities of cesium in leaching tests by atomic absorption spectrometry with electrothermal atomization

    International Nuclear Information System (INIS)

    Crubellati, R.O.; Di Santo, N.R.

    1988-01-01

    An original method for cesium determinations by atomic absorption spectrometry with electrothermal atomization is described. The effect of foreign ions (alkali and earth alkaline metals) present in leaching test of glasses with incorporated radioactive wastes was studied. The effect of different mineral acids was also investigated. A comparison between the flame excitation method and the electrothermal atomization one was made. Under optimum conditions, cesium in quantities down to 700 ng in 1000 ml of sample could be determined. The calibration curve was linear in the range of 0.7 - 15 ng/mL. The fact that the proposed determinations can be performed in a short time and that a small sample volume is required are fundamental advantages of this method, compared with the flame excitation procedure. Besides, it is adaptable to be applied in hot cells and glove boxes. (Author) [es

  2. Practical aspects of the uncertainty and traceability of spectrochemical measurement results by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Duta, S.; Robouch, P.; Barbu, L.; Taylor, P.

    2007-01-01

    The determination of trace elements concentration in water by electrothermal atomic absorption spectrometry (ETAAS) is a common and well established technique in many chemical testing laboratories. However, the evaluation of measurement uncertainty results is not systematically implemented. The paper presents an easy step-by-step example leading to the evaluation of the combined standard uncertainty of copper determination in water using ETAAS. The major contributors to the overall measurement uncertainty are identified due to amount of copper in water sample that mainly depends on the absorbance measurements, due to certified reference material and due to auto-sampler volume measurements. The practical aspects how the traceability of copper concentration in water can be established and demonstrated are also pointed out

  3. Determination of molybdenum in silicates through atomic absorption spectrometry using pre-concentration by active carbon

    International Nuclear Information System (INIS)

    Boaventura, G.R.; Rocha Hirson, J. da; Santelli, R.E.

    1989-01-01

    An analytical procedure for molybdenum determination in geological materials through Atomic Absorption Spectrometry, after pre-concentration of the Mo-APDC complex in activated carbon, has been developed, which is needed in order to reduce the dilution effect in the sample decomposition. During the development of this method the influence of pH, the amount of APDC for complexation of Mo and the interference of Fe, Ca, Mn, Al, K, Na, Mg and Ti were tested. It was shown that none of these causes any significant effect on the Mo determination proposed. The results of the analysis at the international geochemical reference samples JB-1 (basalt) and GH (granite) were very accurate and showed that the detection limit in rocks (1,00g) is 0,6 ppm, when using sample dilution of 1 ml and microinjection techniques. (author) [pt

  4. Analysis of nuclear grade uranium oxides by atomic absorption spectrometry with electrothermal atomization

    International Nuclear Information System (INIS)

    Batistoni, D.A.; Erlijman, L.H.; Pazos, A.L.

    1986-01-01

    The application of atomic absorption spectrometry for the determination of five trace impurities in nuclear grade uranium oxides is described. The elements were separated from the uranium matrix by extraction chromatography and determined in 5.5 M nitric acid by electrothermal atomization using pyrolytic graphite coated tubes. Two elements, cadmium and chromium, with different volatility characteristics were employed to investigate the operating conditions. Drying and ashing conditions were studied for both elements. Ramp and constant potential (step) heating modes have also been studied and compared. Good reproducibility and a longer life of graphite tubes were obtained with ramp atomization. Detection limits (in micrograms per gram of uranium) were: Cd 0.01; Cr 0.1; Cu 0.4; Mn 0.04 and Ni 0.2. (author) [es

  5. Analysis of soil reference materials for vanadium(+5) species by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mandiwana, Khakhathi L.; Panichev, Nikolay

    2010-01-01

    Solid Certified Reference Materials (CRMs) with known vanadium(+5) content are currently not commercially available. Because of this, vanadium species have been determined in solid CRMs of soil, viz. CRM023-50, CRM024-50, CRM049-50, SQC001 and SQC0012. These CRMs are certified with only total vanadium content. Vanadium(+5) was extracted from soil reference materials with 0.1 M Na 2 CO 3 . The quantification of V(+5) was carried out by electrothermal atomic absorption spectrometry (ET-AAS). The concentration of V(+5) in the analyzed CRMs was found to be ranging between 3.60 and 86.0 μg g -1 . It was also found that SQC001 contains approximately 88% of vanadium as V(+5) species. Statistical evaluation of the results of the two methods by paired t-test was in good agreement at 95% level of confidence.

  6. Determination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate.

    Science.gov (United States)

    Selvi, Emine Kılıçkaya; Şahin, Uğur; Şahan, Serkan

    2017-01-01

    This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosphate. The analytical parameters that influenced the quantitative coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte ion were in the range of 95-105 % with limit of detection (3s) of 0.5 µg l -1 . Preconcentration factor was found as 1000 and Relative Standard Deviation (RSD) % value obtained from model solutions was 2.5% for 0.02 mg L -1 . The accuracy of the method was evaluated with standard reference material (CWW-TMD Waste Water). The method was also applied to most concentrated acidic and basic dialysis concentrates with satisfactory results.

  7. [Measurement of thallium content in human urine by atomic absorption spectrometry after acute poisoning].

    Science.gov (United States)

    Luzanova, I S; Pletneva, T V; Maksimova, T V; Salomatin, E M; Lutskiĭ, Ia M

    2008-01-01

    The problem of poisoning with thallium-containing substances continues to be of current concern. According to the Bureau of Forensic Medical Examination, Moscow, specimens of biological materials from more than 20 victims of such poisoning were delivered for analysis in 2006. The total number of thallium poisoning episodes during the period since 1996 exceeded 50. Materials for thallium determination in biological fluids (human blood and urine) using flame atomic absorption spectrometry were prepared by dry mineralization of accurately weighed samples; acidic solutions of the products of mineralization were used for analysis. Due to peculiar kinetic features of thallium ion absorption in the gastro-intestinal tract, blood could not be used as a biological marker of poisoning. The level of thallium in urine samples was found to vary from 1.00 to 4,600 mcg/l (with the estimation of confidence intervals in each case). Results of chemical analysis correlated with pathological symptoms derived from the patients' discharge summaries and literature reports on dose-effect relationships. Based on these findings, practically all the examined cases were characterized as severe acute poisoning.

  8. Slurry analysis after lead collection on a sorbent and its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baysal, Asli; Tokman, Nilgun [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak-Istanbul (Turkey); Akman, Suleyman [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak-Istanbul (Turkey)], E-mail: akmans@itu.edu.tr; Ozeroglu, Cemal [Istanbul University, Department of Chemistry, Faculty of Engineering, 34320 Avcilar-Istanbul (Turkey)

    2008-02-11

    In this study, in order to eliminate the drawbacks of elution step and to reach higher enrichment factors, a novel preconcentration/separation technique for the slurry analysis of sorbent loaded with lead prior to its determination by electrothermal atomic absorption spectrometry was described. For this purpose, at first, lead was collected on ethylene glycol dimethacrylate methacrylic acid copolymer (EGDMA-MA) treated with ammonium pyrolidine dithiocarbamate (APDC) by conventional batch technique. After separation of liquid phase, slurry of the sorbent was prepared and directly pipetted into graphite furnace of atomic absorption spectrophotometer. Optimum conditions for quantitative sorption and preparation of the slurry were investigated. A 100-fold enrichment factor could be easily reached. The analyte element in certified sea-water and Bovine-liver samples was determined in the range of 95% confidence level. The proposed technique was fast and simple and the risks of contamination and analyte loss were low. Detection limit (3{delta}) for Pb was 1.67 {mu}g l{sup -1}.

  9. The Validation of Atomic Absorption Spectrometry (AAS) Method for the Determination of Cr, Cu and Pb

    International Nuclear Information System (INIS)

    Purwanto, A.; Supriyanto, C.; Samin P

    2007-01-01

    The validation of analytical method of atomic absorption spectrometry for the determination of Cr, Cu and Pb by using certified reference materials (CRM) have been carried out. The validation of analytical method was done by measurement of precision, accuracy, bias, % D and % RSD by analysis of chromium (Cr), Copper (Cu), and Lead (Pb) elements in CRM samples. Soil-7 is weighted and dissolved 0.3337 gram to use the bomb digester with concentrated nitric acid, perchloric acid, fluoric acid, and than solution to vinal volume is 10 mL with aquabidest. The validity of instrument atomic absorption spectrometer still valid with obtained of accuracy is 95.85 % and precision is 2.86 for Cr.; 103.32 % and 0.45 for Cu., 114.14 % and 9.89 for Pb. The validation of analytical method showed that with obtained of the content of Cr, Cu and Pb elements is 57.51, 11.37 and 68.49 μg/g., this result is still in the range concentration of certificate. (author)

  10. Application of thermospray flame furnace atomic absorption spectrometry for investigation of silver nanoparticles.

    Science.gov (United States)

    Sirirat, Natnicha; Tetbuntad, Kornrawee; Siripinyanond, Atitaya

    2017-03-01

    Thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was applied to investigate the time-dependent absorption peak profile of various forms of silver. The thermospray flame furnace was set up with a 10-cm-long nickel tube with six holes, each 2.0 mm in diameter, to allow the flame to enter, and this nickel tube acted as a furnace. A sample of 300 μL was introduced into this furnace by use of water as a carrier at a flow rate of 0.5 mL min -1 through the ceramic capillary (0.5-mm inner diameter and 2.0-mm outer diameter), which was inserted into the front hole of the nickel tube. The system was applied to examine atomization behaviors of silver nanoparticles (AgNPs) with particle sizes ranging from 10 to 100 nm. The atomization rate of AgNPs was faster than that of the dissolved silver ion. With increased amount of silver, the decay time observed from the time-dependent absorption peak profile was shortened in the case of dissolved silver ion, but it was increased in the case of AgNPs. With the particle size ranging from 10 to 100 nm, the detection sensitivity was indirectly proportional to the particle size, suggesting that TS-FF-AAS may offer insights into the particle size of AgNPs provided that the concentration of the silver is known. To obtain quantitative information on AgNPs, acid dissolution of the particles was performed before TS-FF-AAS analysis, and recoveries of 80-110% were obtained.

  11. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Science.gov (United States)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L- 1 HNO3 solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L- 1 and 36.4 mg L- 1, respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93-105% with the repeatability in the range of 4.1-5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg- 1), egg white (2188 ± 29 mg kg- 1), mineral water (31.0 ± 0.9 mg L- 1), white wine (260 ± 4 mg L- 1) and red wine (82 ± 2 mg L- 1), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L- 1).

  12. Sample preparation for arsenic speciation analysis in baby food by generation of substituted arsines with atomic absorption spectrometry detection

    Czech Academy of Sciences Publication Activity Database

    Huber, C. S.; Vale, M. G. R.; Dessuy, M. B.; Svoboda, Milan; Musil, Stanislav; Dědina, Jiří

    2017-01-01

    Roč. 175, DEC (2017), s. 406-412 ISSN 0039-9140 R&D Projects: GA MŠk(CZ) LH15174 Institutional support: RVO:68081715 Keywords : slurry sampling * methyl-substituted arsenic species * hydride generation-cryotrapping-atomic absorption spectrometry Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.162, year: 2016

  13. Sample preparation for arsenic speciation analysis in baby food by generation of substituted arsines with atomic absorption spectrometry detection

    Czech Academy of Sciences Publication Activity Database

    Huber, C. S.; Vale, M. G. R.; Dessuy, M. B.; Svoboda, Milan; Musil, Stanislav; Dědina, Jiří

    2017-01-01

    Roč. 175, DEC (2017), s. 406-412 ISSN 0039-9140 R&D Projects: GA MŠk(CZ) LH15174 Institutional support: RVO:68081715 Keywords : slurry sampling * methyl-substituted arsenic species * hydride generation-cryotrapping- atomic absorption spectrometry Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.162, year: 2016

  14. Determination of total selenium in nutritional supplements and selenised yeast by Zeeman-effect graphite furnace atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Ekelund, J.

    1989-01-01

    -effect background corrected graphite furnace atomic absorption spectrometry. A furnace ashing step at 1100 °C was necessary in order to obtain a total recovery of selenium when present in the organic form. Palladium nitrate-magnesium nitrate was used as a matrix modifier. Independent methods were used to determine...

  15. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    International Nuclear Information System (INIS)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-01-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L −1 HNO 3 solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L −1 and 36.4 mg L −1 , respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93–105% with the repeatability in the range of 4.1–5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg −1 ), egg white (2188 ± 29 mg kg −1 ), mineral water (31.0 ± 0.9 mg L −1 ), white wine (260 ± 4 mg L −1 ) and red wine (82 ± 2 mg L −1 ), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L −1 ). - Highlights: • HR-CS FMAS technique was used for sulfur measurement via molecular absorption of carbon monosulfide, CS. • Organic DL-cysteine in 0.2 mol L −1 HNO 3 solution is

  16. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata, E-mail: bgodlew@uwb.edu.pl

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L{sup −1} HNO{sub 3} solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L{sup −1} and 36.4 mg L{sup −1}, respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93–105% with the repeatability in the range of 4.1–5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg{sup −1}), egg white (2188 ± 29 mg kg{sup −1}), mineral water (31.0 ± 0.9 mg L{sup −1}), white wine (260 ± 4 mg L{sup −1}) and red wine (82 ± 2 mg L{sup −1}), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L{sup −1}). - Highlights: • HR-CS FMAS technique was used for sulfur measurement via molecular absorption of carbon monosulfide, CS. • Organic DL

  17. Use of electrothermal atomic absorption spectrometry for size profiling of gold and silver nanoparticles.

    Science.gov (United States)

    Panyabut, Teerawat; Sirirat, Natnicha; Siripinyanond, Atitaya

    2018-02-13

    Electrothermal atomic absorption spectrometry (ETAAS) was applied to investigate the atomization behaviors of gold nanoparticles (AuNPs) and silver nanoparticles (AgNPs) in order to relate with particle size information. At various atomization temperatures from 1400 °C to 2200 °C, the time-dependent atomic absorption peak profiles of AuNPs and AgNPs with varying sizes from 5 nm to 100 nm were examined. With increasing particle size, the maximum absorbance was observed at the longer time. The time at maximum absorbance was found to linearly increase with increasing particle size, suggesting that ETAAS can be applied to provide the size information of nanoparticles. With the atomization temperature of 1600 °C, the mixtures of nanoparticles containing two particle sizes, i.e., 5 nm tannic stabilized AuNPs with 60, 80, 100 nm citrate stabilized AuNPs, were investigated and bimodal peaks were observed. The particle size dependent atomization behaviors of nanoparticles show potential application of ETAAS for providing size information of nanoparticles. The calibration plot between the time at maximum absorbance and the particle size was applied to estimate the particle size of in-house synthesized AuNPs and AgNPs and the results obtained were in good agreement with those from flow field-flow fractionation (FlFFF) and transmission electron microscopy (TEM) techniques. Furthermore, the linear relationship between the activation energy and the particle size was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Ultrasound assisted pseudo-digestion of street dust samples prior to determination by atomic absorption spectrometry.

    Science.gov (United States)

    Elik, Adil

    2005-05-15

    A sample preparation method based on ultrasound assisted pseudo-digestion of Pb, Cu, Zn and Ni from street dust samples under ultrasonic effect has been described. Parameters influencing pseudo-digestion, such as sonication time, sample mass, particle size and solvent system were fully optimized. Final solutions obtained upon sonication were analyzed by atomic absorption spectrometry. The best conditions for metal pseudo-digestion were as follows: a 25min sonication time, a 0.3g sample mass (in 25ml solvent), a particle size <63mum and a mixture of concentrated HNO(3)-HClO(4)-HF (2:1:1, v/v/v). Analytical results for the four metals by ultrasound assisted pseudo-digestion, acid bomb and conventional wet digestion methods showed a good agreement, thus indicating the possibility of using mild conditions for sample preparation instead of intensive treatments inherent with the digestion methods. In addition, this method reduces the time required for all treatments (pseudo-digestion or digestion, heating to dryness, cooling and separation) with acid bomb and conventional wet digestion methods approximately from 9 to 1h. The accuracy of the method was tested either by comparing obtained results with those of acid bomb and conventional wet digestion methods or by application on two standard reference materials. The average relative standard deviation of ultrasound assisted pseudo-digestion method varied between 0.9 and 1.8% for N=12, depending on the analyte.

  19. Bismuth determination in environmental samples by hydride generation-electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso-Perez, Carmen; Moreda-Pineiro, Jorge; Lopez-Mahia, Purificacion; Muniategui-Lorenzo, Soledad; Fernandez-Fernandez, Esther; Prada-Rodriguez, Dario [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071, A Coruna (Spain)

    2003-12-04

    A hydride generation procedure, via flow injection, coupled to electrothermal atomic absorption spectrometry was optimised for Bi determination in sea water and hot-spring water and acid extracts from coal, coal fly ash and slag samples. The effects of several variables such as hydrochloric acid and sodium tetrahydroborate concentrations, hydrochloric acid and sodium tetrahydroborate flow rates, reaction coil length, trapping and atomisation temperatures, trapping time and the Ar flow rate have been investigated by using a 2{sup 9}*3/128 Plackett-Burman design. From these studies, certain variables (sodium tetrahydroborate concentration and trapping time) showed up as significant, and they were optimised by a 2{sup 2}+star central composite design. In addition, a study of the bismuthine trapping and atomisation efficiency from graphite tubes (GTs) permanently treated with uranium, tantalum, lanthanum oxide, niobium, beryllium oxide, chromium oxide and tantalum carbide were investigated. The results obtained were compared with those achieved by iridium and zirconium-treated GTs. The best analytical performances, with characteristic mass of 35 pg and detection limit of 70 ng l{sup -1}, were achieved by using U-treated GTs. Accuracy were checked using several reference materials: 1643d (Trace Elements in Water), TM-24 (Reference Water), GBW-07401 (Soil) and 1632c (Trace Elements in Coal)

  20. Ultraviolet differential optical absorption spectrometry: quantitative analysis of the CS2 produced by SF6 decomposition

    Science.gov (United States)

    Zhang, Xiaoxing; Zhou, Hong; Chen, Chuan; Li, Xin; Cui, Zhaolun; Xiao, Song; Tang, Ju

    2017-11-01

    The occurrence of partial discharge or partial overthermal fault in sulfur hexafluoride (SF6)-insulated electrical equipment frequently causes SF6 and solid insulation materials to decompose into various products. One of the most characteristic products of this process is carbon disulfide (CS2). The internal fault type and severity of the fault in the insulation equipment can be detected through the accurate quantitative detection of CS2. A device for simultaneously determining and quantifying gaseous CS2 via ultraviolet differential optical absorption spectrometry is developed in this study. A Sym14 wavelet transform and fast Fourier transform (FFT) are applied to process the spectral data of the feature regions, namely 190 nm to 210 nm. The concentration of CS2 is determined, and the detection limit of the developed device is identified. A good linear relationship is observed between the characteristic peaks of FFT and the concentration of CS2 after the operational parameters are optimized. Along the light path at 600 mm, the average detection limit for CS2 is 8.65 ppb based on three times the standard deviation of the system noises. The proposed device, which exhibits high sensitivity and effective cost, addresses the urgent demand for the monitoring and diagnosis of SF6-insulated electrical equipment via online detection of trace CS2.

  1. Determination of tellurium by hydride generation with in situ trapping flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Matusiewicz, H.; Krawczyk, M. [Politechn Poznanska, Poznan (Poland)

    2007-03-15

    The analytical performance of coupled hydride generation - integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) system was evaluated for determination of Te in reference material (GBW 07302 Stream Sediment), coal fly ash and garlic. Tellurium, using formation of H{sub 2}Te vapors, is atomized in air-acetylene flame-heated IAT. A new design HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangernents (a water-cooled single silica tube, double-slotted quartz tube or an 'integrated trap') was investigated. An improvement in detection limit was achieved compared with using either of the above atom trapping techniques separately. The concentration detection limit, defined as 3 times the blank standard deviation (3{sigma}), was 0.9 ng mL{sup -1} for Te. For a 2 min in situ preconcentration time (sample volume of 2 mL), sensitivity enhancement compared to flame AAS, was 222 fold, using the hydride generation atom trapping technique. The sensitivity can be further improved by increasing the collection time. The precision, expressed as RSD, was 7.0% (n = 6) for Te. The accuracy of the method was verified using a certified reference material (GBW 07302 Stream Sediment) by aqueous standard calibration curves. The measured Te contents of the reference material was in agreement with the information value. The method was successfully applied to the determination of tellurium in coal fly ash and garlic.

  2. Arsenic speciation in natural water samples by coprecipitation-hydride generation atomic absorption spectrometry combination.

    Science.gov (United States)

    Tuzen, Mustafa; Citak, Demirhan; Mendil, Durali; Soylak, Mustafa

    2009-04-15

    A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO(4), the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 microg L(-1). The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.

  3. Determination of iron in natural and mineral waters by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    ROLANDAS KAZLAUSKAS

    2004-05-01

    Full Text Available Simple methods for the determination of Fe in natural and mineral waters by flame atomic absorption spectrometry (AAS are suggested. The results of the investigation of selectivity of the proposed AAS method proved that this procedure is not affected by high concentrations of other metals. The calibration graph for iron was linear at levels near the detection limit up to at least 0.10 mg ml-1. For the determination of microamounts of iron in mineral waters, an extraction AAS technique was developed. Iron was retained as Fe-8-oxyquinoline complex and extracted into chloroform. The optimal conditions for the extraction of the iron complex were determined. The AAS method was applied to the determination of Fe in mineral waters and natural waters from different areas of Lithuania. The accuracy of the developed method was sufficient and evaluated in comparison with a photometric method. The obtained results demonstrated that the procedure could be successfully applied for the analysis of water samples with satisfactory accuracy.

  4. Determination of cadmium in coal by metal furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Fudagawa, Noriko; Kawase, Akira

    1985-01-01

    Conditions for determination of cadmium in coal were investigated by atomic absorption spectrometry using a boat-shape tungsten furnace. For concentrating and separating cadmium from the coexisting components cadmium dithizonate-m-xylene solution and the 0.05 mol/l perchloric acid solution were examined. Ashing and atomizing temperatures, sheath gas composition, distribution of the cadmium atoms in the furnace were examined. Similar characteristics were obtained for the determination of cadmium in perchloric acid solution and the chelate m-xylene solution, except that a reduction of the peak time and FWHM (full width at half maximum) was observed for the latter solution. When the atomization temperature is near 2300 deg C, the change in the magnitude of absorbance is small in terms of the temperature. The influence of hydrogen contained in the sheath gas was complicated: Change in the thermal conductivity with increasing hydrogen content, resulted decrease of the atomization temperature but the integrated absorbance did not change so much. The concentration of cadmium atoms decreased linearily in the vertical direction of the furnace, while absorbance in the horizontal direction was almost constant. Cadmium in coal was determined by the methods (1) solvent extraction, (2) back-extraction with perchloric acid, (3) on-boat standard addition method. (author)

  5. Oxygen diluted hexamethyldisiloxane plasmas investigated by means of in situ infrared absorption spectroscopy and mass spectrometry

    Science.gov (United States)

    Magni, D.; Deschenaux, Ch; Hollenstein, Ch; Creatore, A.; Fayet, P.

    2001-01-01

    The gas phase species produced in rf plasmas of hexamethyldisiloxane (HMDSO), Si2O(CH3)6, diluted with oxygen, have been investigated. The complementarity of Fourier transform infrared absorption spectroscopy and mass spectrometry allows the determination of the most abundant neutral components present in the discharge. The measurements reveal that methyl groups (CH3), abundantly formed by the dissociation of the HMDSO molecule, are the precursor for the most abundant species which stem from two kinds of reaction. The first kind of reaction is combustion of CH3 by oxygen-producing formaldehyde (COH2), formic acid (CO2H2), carbon monoxide (CO), carbon dioxide (CO2) and water. It is shown that high mass carbonated radicals, such as SixOyCzHt, first diffuse to the surface and then the carbon is removed by oxygen etching to form CO2. The second is hydrocarbon chemistry promoted by CH3, producing mainly hydrogen (H2), methane (CH4) and acetylene (C2H2).

  6. Determination of thallium in potassium chloride and electrolyte replenishers by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Nukatsuka, Isoshi; Horiguchi, Ryo; Seitoh, Hiroyuki; Ohzeki, Kunio; Miyashita, Fumihide

    2004-01-01

    Thallium in potassium chloride and electrolyte replenishers was determined by electrothermal atomic absorption spectrometry (ETAAS) with direct injection of a resin suspension. Thallium(III) was extracted on fine particles of a cellulose nitrate resin (CNR) from dilute HCl (pH 1.6) in the presence of ammonium pyrrolidine-1-carbodithioate. The CNR particles were collected on a membrane filter by filtration under suction, suspended in 1.0 mL 10mM HNO3, and then delivered directly to ETAAS as the suspension. The effects of chloride ions were thoroughly investigated. The results showed that the addition of 0.5mM NaCl to the suspension (10mM HNO3) was recommended, after CNR and a membrane filter holding the CNR were washed thoroughly with 0.025M HCl, to eliminate interference from chloride ions. No chemical modifier was required. Extraction from the solution containing up to 2M chloride ion was allowable. The proposed method gave a concentration factor of 50 for a 50 mL sample volume. The detection limit (3sigma, n = 5) was 1 ng (20 pg/mL). The relative standard deviation was 4.9% (n = 5) at 30 ng level of thallium. The content of thallium in potassium chloride was 15.7-32.8 ng/g, and in electrolyte replenishers was 0.18-4.16 ng/mL.

  7. Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Resano, M.; Mozas, E.; Crespo, C.; Pérez, J.; García-Ruiz, E.; Belarra, M. A.

    2012-05-01

    This paper reports on the use of solid sampling-graphite furnace atomic absorption spectrometry for the direct analysis of synthetic amorphous silica. In particular, determination of hazardous elements such As, Cd, Cr, Cu, Pb and Sb is investigated, as required by regulations of the food industry. The conclusion of the work is that, after proper optimization of the working conditions, paying particular attention to the atomization temperature and the use of proper modifiers (graphite powder, HNO3 or Pd), it is possible to develop suitable procedures that rely on the use of aqueous standard solutions to construct the calibration curves for all the elements investigated. The proposed method shows important benefits for the cost-effective analysis of such difficult samples in routine labs, permitting fast screening of those elements that are very rarely present in this type of sample, but also accurate quantification of those often found, while offering low limits of detection (always below 0.1 mg g- 1) that comply well with legal requirements, and precision levels that are fit for the purpose (approx. 6-9% R.S.D.).

  8. Self-absorption corrections of various sample-detector geometries in gamma-ray spectrometry using sample Monte Carlo Simulations

    International Nuclear Information System (INIS)

    Ahmad Saat; Appleby, P.G.; Nolan, P.J.

    1997-01-01

    Corrections for self-absorption in gamma-ray spectrometry have been developed using a simple Monte Carlo simulation technique. The simulation enables the calculation of gamma-ray path lengths in the sample which, using available data, can be used to calculate self-absorption correction factors. The simulation was carried out on three sample geometries: disk, Marinelli beaker, and cylinder (for well-type detectors). Mathematical models and experimental measurements are used to evaluate the simulations. A good agreement of within a few percents was observed. The simulation results are also in good agreement with those reported in the literature. The simulation code was carried out in FORTRAN 90,

  9. Determination of trace amounts of selenium in minerals and rocks by flame less atomic-absorption spectrometry

    International Nuclear Information System (INIS)

    Alduan, F. A.; Capdevilla, C.

    1980-01-01

    The determination of trace amounts of selenium In silicate rocks and feldspar by solvent extraction and graphite furnace atomic-absorption spectrometry has been stu- died. Sodium diethyl-ditio carbamate and ammonium pyrrolidine dithiocarbamate have been tried as chelating agents. The best results are achieved when selenium is extracted Into carbon tetrachloride as the sodium diethyldithiocarbamate complex. The method allows to detect 0,75 ppm of selenium in the sample. Recoveries are about 100%. (Author) 7 refs

  10. Determination of calcium, copper, chromium, iron, magnesium, manganese, potassium, sodium and zinc in ethanol by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Fernandes, E.A.N.

    1981-01-01

    The direct determinacao of calcium, copper, chomium, iron, magnesium, manganese, potassium, sodium and zinc in ethanol by atomic absorption spectrometry with, air-acetylene flame is proposed. Effects of fuel/oxidant ratio, burner height and water content in the samples were investigated in detail. The method allows the determition of the elements with good precision (r.s.d. -1 for the elements tested. (author) [pt

  11. Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heitmann, Uwe; Becker-Ross, Helmut; Katskov, Dmitri

    2006-01-01

    A prototype spectrometer for high-resolution continuum source atomic absorption spectrometry (HR-CS AAS), built at ISAS Berlin, Germany, was combined with a graphite filter atomizer (GFA), earlier developed at TUT, Pretoria, South Africa. The furnace and auto-sampler units from a commercial AA spectrometer, model AAS vario 6 (Analytik Jena AG, Jena, Germany), were employed in the instrument. Instead of conventional platform tube, the GFA was used to provide low measurement susceptibility to interferences and short determination cycle. The GFA was modified according to the design of the furnace unit and optimal physical parameters of its components (filter and collector) found. Afterwards, optimal GFA was replicated and tested to outline analytical performances of the HR-CS GFA AA spectrometer in view of prospects of multi-element analysis. In particular, reproducibility of performances, repeatability of analytical signals, lifetime, temperature limit and duration of the measurement cycle were examined, and elements available for determination justified. The results show that the peak area of the atomic absorption signal is reproduced in various GFA copies within ± 4% deviation range. The GFA can stand temperatures of 2800 deg. C with 6 s hold time for 55 temperature cycles, and 2700 deg. C (8 s) for about 200 cycles. Only the external tube is prone to destruction while the filter and collector do not show any sign of erosion caused by temperature or aggressive matrix. Analytical signals are affected insignificantly by tube aging. Repeatability of the peak area remains within 1.1-1.7% RSD over more than hundred determination cycles. Peak areas are proportional to the sample volume of injected organic and inorganic liquids up to at least 50 μL. The drying stage is combined with hot sampling and cut down to 15-20 s. The list of metals available for determination with full vapor release includes Al, Co, Cr, Ni, Pt as well as more volatile metals. Characteristic

  12. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    International Nuclear Information System (INIS)

    Katskov, Dmitri

    2015-01-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D 2 and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  13. Methods of calibration in the direct analysis of solid samples by electrothermal atomic absorption spectrometry

    Science.gov (United States)

    Berglund, M.; Baxter, D. C.

    1992-12-01

    One of the major problems involved in the direct analysis of solid samples by electrothermal atomic absorption spectrometry (ETAAS) lies in the calibration step because non-spectral interference effects are often pronounced. Three standardization techniques have been described and used in solid sampling-ETAAS: (i) standard additions method; (ii) calibration relative to a certified reference material; and (iii) calibration curve technique. However, an adequate statistical evaluation of the uncertainty in the analyte concentration in the solid sample is most frequently neglected, and reported errors may be seriously underestimated. This can be attributed directly to the complexity of the statistical expressions required to accurately account for errors in each of the calibration techniques mentioned above, and the general lack of relevant reference literature. The object of this work has been to develop a computer package which will perform the necessary statistical analyses of solid sampling-ETAAS data; the result is the program "SOLIDS" described here in the form of an electronic publication in Spectrochimica Acta Electronica, the electronic section of Spectrochimica Acta Part B. The program could also be useful in other analytical fields where similar calibration methods are used. The hard copy text, outlining the calibration models and their associated errors, is accompanied by a diskette containing the program, some data files, and a manual. Use of the program is exemplified in the text, with some of the data files discussed included on the diskette which, together with the manual, should enable the reader to become familiarized with the operation of the program, and the results generated.

  14. Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Rey-Raap, Natalia; Gallardo, Antonio

    2012-01-01

    Highlights: ► New treatments for CFL are required considering the aim of Directive 202/96/CE. ► It is shown that most of the mercury introduced into a CFL is in the phosphor powder. ► Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. ► By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 ± 0.4 ppb of mercury in the vapor phase, 204.16 ± 8.9 ppb of mercury in the phosphor powder, and 18.74 ± 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

  15. A comparison of simultaneous plasma, atomic absorption, and iron colorimetric determinations of major and trace constituents in acid mine waters

    Science.gov (United States)

    Ball, J.W.; Nordstrom, D. Kirk

    1994-01-01

    Sixty-three water samples collected during June to October 1982 from the Leviathan/Bryant Creek drainage basin were originally analyzed by simultaneous multielement direct-current plasma (DCP) atomic-emission spectrometry, flame atomic-absorption spectrometry, graphite-furnace atomic-absorption spectrometry (GFAAS) (thallium only), ultraviolet-visible spectrometry, and hydride-generation atomic-absorption spectrometry.Determinations were made for the following metallic and semi-metallic constituents: AI, As, B, Ba, Be, Bi, Cd, Ca, Cr, Co, Cu, Fe(11), Fe(total), Li, Pb, Mg, Mn, Mo, Ni, K, Sb, Se, Si, Na, Sr, TI, V, and Zn. These samples were re-analyzed later by simultaneous multielement inductively coupled plasma (ICP) atomic-emission spectrometry and Zeeman-corrected GFAAS to determine the concentrations of many of the same constituents with improved accuracy, precision, and sensitivity. The result of this analysis has been the generation of comparative concentration values for a significant subset of the solute constituents. Many of the more recently determined values replace less-than-detection values for the trace metals; others constitute duplicate analyses for the major constituents. The multiple determinations have yielded a more complete, accurate, and precise set of analytical data. They also have resulted in an opportunity to compare the performance of the plasma-emission instruments operated in their respective simultaneous multielement modes. Flame atomic-absorption spectrometry was judged best for Na and K and hydride-generation atomic-absorption spectrometry was judged best for As because of their lower detection limit and relative freedom from interelement spectral effects. Colorimetric determination using ferrozine as the color agent was judged most accurate, precise, and sensitive for Fe. Cadmium, lead, and vanadium concentrations were too low in this set of samples to enable a determination of whether ICP or DCP is a more suitable technique. Of

  16. Method 200.12 - Determination of Trace Elements in Marine Waters by StabilizedTemperature Graphite Furnace Atomic Absorption

    Science.gov (United States)

    This method provides procedures for the determination of total recoverable elements by graphite furnace atomic absorption (GFAA) in marine waters, including estuarine, ocean and brines with salinities of up to 35 ppt.

  17. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    Science.gov (United States)

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  18. Speciation of four selenium compounds using high performance liquid chromatography with on-line detection by inductively coupled plasma mass spectrometry or flame atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Pedersen, Gitte Alsing; Larsen, Erik Huusfeldt

    1997-01-01

    with an aqueous solution of 6 mmol L-1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass......An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination...... spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 sigma) achieved by the HPLC-FAAS system was 1 mg L-1 of selenium (100 mu L injections) for each of the four...

  19. Fluorine determination in coal using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Patrícia M.; Morés, Silvane; Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Welz, Bernhard, E-mail: w.bernardo@terra.com.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Carasek, Eduardo [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil)

    2015-03-01

    The absorption of the calcium mono-fluoride (CaF) molecule has been employed in this study for the determination of fluorine in coal using direct solid sample analysis and high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS). The rotational line at 606.440 nm was used for measuring the molecular absorption in the gas phase. The pyrolysis and vaporization temperatures were 700 °C and 2100 °C, respectively. Different chemical modifiers have been studied, such as Pd and Ir as permanent modifiers, and Pd and the mixed Pd/Mg modifier in solution. The limit of detection and the characteristic mass were 0.3 and 0.1 ng F, respectively. One certified reference material (CRM) of coal (NIST 1635) and four CRMs with a non-certified value for F (SARM 18, SARM 20, BCR 40, BCR 180) were used to evaluate the accuracy and precision of the method, obtaining good agreement (104%) with the certified value and with the informed values (ranging from 90 to 103%). - Highlights: • High-resolution Graphite Furnace Molecular Absorption Spectrometry (HR-GF MAS) • Fluorine has been determined using HR-GF MAS of the CaF molecule. • The CaF molecule was generated in a graphite furnace at a temperature of 2100 °C • Coal samples have been analyzed using direct solid sample introduction. • Aqueous standard solutions have been used for calibration.

  20. Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sardans, Jordi, E-mail: j.sardans@creaf.uab.ca [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain); Montes, Fernando [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), C/ Senda del Rey 9. 28040 Madrid (Spain); Penuelas, Josep [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain)

    2010-02-15

    Pollution from heavy metals has increased in recent decades and has become an important concern for environmental agencies. Arsenic, cadmium, copper, mercury and lead are among the trace elements that have the greatest impact and carry the highest risk to human health. Electrothermal atomic absorption spectrometry (ETAAS) has long been used for trace element analyses and over the past few years, the main constraints of atomic absorption spectrometry (AAS) methods, namely matrix interferences that provoked high background absorption and interferences, have been reduced. The use of new, more efficient modifiers and in situ trapping methods for stabilization and pre-concentration of these analytes, progress in control of atomization temperatures, new designs of atomizers and advances in methods to correct background spectral interferences have permitted an improvement in sensitivity, an increase in detection power, reduction in sample manipulation, and increase in the reproducibility of the results. These advances have enhanced the utility of Electrothermal atomic absorption spectrometry (ETAAS) for trace element determination at mug L{sup -1} levels, especially in difficult matrices, giving rise to greater reproducibility, lower economic cost and ease of sample pre-treatment compared to other methods. Moreover, the recent introduction of high resolution continuum source Electrothermal atomic absorption spectrometry (HR-CS-ETAAS) has facilitated direct solid sampling, reducing background noise and opening the possibility of achieving even more rapid quantitation of some elements. The incorporation of flow injection analysis (FIA) systems for automation of sample pre-treatment, as well as chemical vapor generation renders (ETAAS) into a feasible option for detection of As and Hg in environmental and food control studies wherein large numbers of samples can be rapidly analyzed. A relatively inexpensive approach with low sample consumption provide additional advantages

  1. Speciation analysis of arsenic in biological matrices by automated hydride generation-cryotrapping-atomic absorption spectrometry with multiple microflame quartz tube atomizer (multiatomizer).

    Science.gov (United States)

    This paper describes an automated system for the oxidation state specific speciation of inorganic and methylated arsenicals by selective hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer. The corresponding arsines are ge...

  2. Application of Zeeman graphite furnace atomic absorption spectrometry with high-frequency modulation polarization for the direct determination of aluminum, beryllium, cadmium, chromium, mercury, manganese, nickel, lead, and thallium in human blood.

    Science.gov (United States)

    Ivanenko, Natalya B; Solovyev, Nikolay D; Ivanenko, Anatoly A; Ganeev, Alexander A

    2012-10-01

    Determination of aluminum (Al), beryllium (Be), cadmium (Cd), chromium (Cr), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and thallium (Tl) concentrations in human blood using high-frequency modulation polarization Zeeman graphite furnace atomic absorption spectrometry (GFAAS) was performed. No sample digestion was used in the current study. Blood samples were diluted with deionized water or 0.1 % (m/v) Triton X-100 solution for Tl. Dilution factors ranged from 1/5 per volume for Be and Tl to 1/20 per volume for Cd and Pb. For Tl, Cd, and Hg, noble metals (gold, platinum, rhodium, etc.) were applied as surface modifiers. To mitigate chloride interference, 2 % (m/v) solution of NH(4)NO(3) was used as matrix modifier for Tl and Ni assessment. The use of Pd(NO(3))(2) as oxidative modifier was necessary for blood Hg and Tl measurement. Validation of the methods was performed by analyzing two-level reference material Seronorm. The precision of the designed methods as relative SD was between 4 and 12 % (middle of a dynamic range) depending on the element. For additional validation, spiked blood samples were analyzed. Limits of detection (LoDs, 3σ, n = 10) for undiluted blood samples were 2.0 μg L(-1) for Al, 0.08 μg L(-1) for Be, 0.10 μg L(-1) for Cd, 2.2 μg L(-1) for Cr, 7 μg L(-1) for Hg, 0.4 μg L(-1) for Mn, 2.3 μg L(-1) for Ni, 3.4 μg L(-1) for Pb, and 0.5 μg L(-1) for Tl. The LoDs achieved allowed determination of Al, Cd, Cr, Mn, Ni, and Pb at both toxic and background levels. Be, Hg, and Tl could be reliably measured at toxic levels only. The methods developed are used for clinical diagnostics and biological monitoring of work-related exposure.

  3. Determination of palladium, platinum and rhodium in used automobile catalysts and active pharmaceutical ingredients using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Resano, Martín, E-mail: mresano@unizar.es [Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza (Spain); Flórez, María del Rosario [Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza (Spain); Queralt, Ignasi [Institute of Earth Sciences Jaume Almera ICTJA-CSIC, Sole Sabarís s/n, 08028 Barcelona (Spain); Marguí, Eva [Department of Chemistry, Faculty of Sciences, Universitat de Girona, Campus Montilivi s/n, 17071 Girona (Spain)

    2015-03-01

    This work investigates the potential of high-resolution continuum source graphite furnace atomic absorption spectrometry for the direct determination of Pd, Pt and Rh in two samples of very different nature. While analysis of active pharmaceutical ingredients is straightforward and it is feasible to minimize matrix effects, to the point that calibration can be carried out against aqueous standard solutions, the analysis of used automobile catalysts is more challenging requiring the addition of a chemical modifier (NH{sub 4}F·HF) to help in releasing the analytes, a more vigorous temperature program and the use of a solid standard (CRM ERM®-EB504) for calibration. However, in both cases it was possible to obtain accurate results and precision values typically better than 10% RSD in a fast and simple way, while only two determinations are needed for the three analytes, since Pt and Rh can be simultaneously monitored in both types of samples. Overall, the methods proposed seem suited for the determination of these analytes in such types of samples, offering a greener and faster alternative that circumvents the traditional problems associated with sample digestion, requiring a small amount of sample only (0.05 mg per replicate for catalysts, and a few milligrams for the pharmaceuticals) and providing sufficient sensitivity to easily comply with regulations. The LODs achieved were 6.5 μg g{sup −1} (Pd), 8.3 μg g{sup −1} (Pt) and 9.3 μg g{sup −1} (Rh) for catalysts, which decreased to 0.08 μg g{sup −1} (Pd), 0.15 μg g{sup −1} (Pt) and 0.10 μg g{sup −1} (Rh) for pharmaceuticals. - Highlights: • Solid sampling HR CS GFAAS permits the fast and direct determination of Pd, Pt and Rh. • 2 determinations suffice for the 3 elements (2 of them can be measured simultaneously). • Samples as different as car catalysts and pharmaceuticals can be accurately analyzed. • Aqueous standards (pharmaceuticals) or a solid CRM (catalysts) is used for calibration.

  4. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    Science.gov (United States)

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  5. Determination of concentration of heavy metals (Pb, Cd, Fe) in animal tissues using atomic absorption spectrometry

    International Nuclear Information System (INIS)

    RAZAFINTSALAMA, V.T.

    2009-01-01

    Heavy metals are classified among the inorganic compounds. The latter type of metal is found in rocks, fertilizers, urban mud but may also originate from the atmospheric pollution. A particular characteristic of heavy metals is their bioaccumulation in the food chain. Therefore, lead and cadmium, which are classified as heavy metals may be easily found in animal products and can lead to food poisoning if their concentrations are higher than the maximum permissible values as requested by international agencies such as the c odex alimentarius . The values are set down and differ according to types of food for human consuption and the trading companies take action accordingly. Therefore, it is necessary to set up a quality control system through analytical laboratory measurements and testings. This study underlies the method of determination of lead, cadmium and iron in animal tissues by atomic absorption spectrometry. The results showed that the method is sensitive and reliable. For each analyte, the Z-score lies between -2 and 2, indicating that the method is working properly. The analytical results showed that: (i) only beef and chicken meats and beef liver contain lead [0,09μg.g - 1; 0,29μg.g - 1]. The limit value of 0,1μg.g - 1 is almost reached in beef and chicken meats, (ii) as far as cadmium is concerned, the five studied samples contain this analyte [0,02μg.g - 1; 0,9μg.g - 1]. Except the chicken liver of which the concentration (0,15μg.g - 1) exceeds the maximum permissible value (0,1μg.g - 1), the others are in conformity with the standards and appropriate to be consumed,(iii) iron is higher in the liver and kidney samples: beef liver 282mg.g - 1, chicken liver 250 mg.g - 1, pork kidney 247mg.g - 1. The study also showed that the calcium concentration in animal tissues is low and they can be classified as poor-calcium food. [fr

  6. Optimized determination of calcium in grape juice, wines, and other alcoholic beverages by atomic absorption spectrometry.

    Science.gov (United States)

    Olalla, Manuel; González, Maria Cruz; Cabrera, Carmen; Gimenez, Rafael; López, Maria Carmen

    2002-01-01

    This paper describes a study of the different methods of sample preparation for the determination of calcium in grape juice, wines, and other alcoholic beverages by flame atomic absorption spectrometry; results are also reported for the practical application of these methods to the analysis of commercial samples produced in Spain. The methods tested included dealcoholization, dry mineralization, and wet mineralization with heating by using different acids and/or mixtures of acids. The sensitivity, detection limit, accuracy, precision, and selectiviy of each method were established. Such research is necessary because of the better analytical indexes obtained after acid digestion of the sample, as recommended by the European Union, which advocates the direct method. In addition, although high-temperature mineralization with an HNO3-HCIO4 mixture gave the best analytical results, mineralization with nitric acid at 80 degrees C for 15 min gave the most satisfactory results in all cases, including those for wines with high levels of sugar and beverages with high alcoholic content. The results for table wines subjected to the latter treatment had an accuracy of 98.70-99.90%, a relative standard deviation of 2.46%, a detection limit of 19.0 microg/L, and a determination limit of 31.7 microg/L. The method was found to be sufficiently sensitive and selective. It was applied to the determination of Ca in grape juice, different types of wines, and beverages with high alcoholic content, all of which are produced and widely consumed in Spain. The values obtained for Ca were 90.00 +/- 20.40 mg/L in the grape juices, 82.30 +/- 23.80 mg/L in the white wines, 85.00 +/- 30.25 mg/L in the sweet wines, 84.92 +/- 23.11 mg/L in the red wines, 85.75 +/- 27.65 mg/L in the rosé wines, 9.51 +/- 6.65 mg/L in the brandies, 11.53 +/- 6.55 mg/L in the gin, 7.3 +/- 6.32 mg/L in the pacharán, and 8.41 +/- 4.85 mg/L in the anisettes. The method is therefore useful for routine analysis in the

  7. Determination of Sodium, Potassium, Magnesium, and Calcium Minerals Level in Fresh and Boiled Broccoli and Cauliflower by Atomic Absorption Spectrometry

    Science.gov (United States)

    Nerdy

    2018-01-01

    Vegetables from the cabbage family vegetables consumed by many people, which is known healthful, by eaten raw, boiled, or cooked (stir fry or soup). Vegetables like broccoli and cauliflower contain vitamins, minerals, and fiber. This study aims to determine the decrease percentage of sodium, potassium, magnesium, and calcium minerals level caused by boiled broccoli and cauliflower by atomic absorption spectrometry. Boiled broccoli and cauliflower prepared by given boiled treatment in boiling water for 3 minutes. Fresh and boiled broccoli and cauliflower carried out dry destruction, followed by quantitative analysis of sodium, potassium, magnesium, and calcium minerals respectively at a wavelength of 589.0 nm; 766.5 nm; 285.2 nm; and 422.7 nm, using atomic absorption spectrometry methods. After the determination of the sodium, potassium, magnesium, and calcium minerals level followed by validation of analytical methods with accuracy, precision, linearity, range, limit of detection (LOD), and limit of quantitation (LOQ) parameters. Research results show a decrease in the sodium, potassium, magnesium, and calcium minerals level in boiled broccoli and cauliflower compared with fresh broccoli and cauliflower. Validation of analytical methods gives results that spectrometry methods used for determining sodium, potassium, magnesium, and calcium minerals level are valid. It concluded that the boiled gives the effect of decreasing the minerals level significantly in broccoli and cauliflower.

  8. [Evaluation of uncertainty for determination of tin and its compounds in air of workplace by flame atomic absorption spectrometry].

    Science.gov (United States)

    Wei, Qiuning; Wei, Yuan; Liu, Fangfang; Ding, Yalei

    2015-10-01

    To investigate the method for uncertainty evaluation of determination of tin and its compounds in the air of workplace by flame atomic absorption spectrometry. The national occupational health standards, GBZ/T160.28-2004 and JJF1059-1999, were used to build a mathematical model of determination of tin and its compounds in the air of workplace and to calculate the components of uncertainty. In determination of tin and its compounds in the air of workplace using flame atomic absorption spectrometry, the uncertainty for the concentration of the standard solution, atomic absorption spectrophotometer, sample digestion, parallel determination, least square fitting of the calibration curve, and sample collection was 0.436%, 0.13%, 1.07%, 1.65%, 3.05%, and 2.89%, respectively. The combined uncertainty was 9.3%.The concentration of tin in the test sample was 0.132 mg/m³, and the expanded uncertainty for the measurement was 0.012 mg/m³ (K=2). The dominant uncertainty for determination of tin and its compounds in the air of workplace comes from least squares fitting of the calibration curve and sample collection. Quality control should be improved in the process of calibration curve fitting and sample collection.

  9. Air quality status in Kinshasa as determined by instrumental neutron activation analysis, atomic absorption spectrometry and ion-exchange chromatography

    International Nuclear Information System (INIS)

    Lobo, K.K.

    1991-01-01

    Three independent analytical techniques - instrumental neutron activation analysis. Atomic absorption spectrometry and ion-exchange chromatography - were applied to airborne particulate collected on filters and to atmospheric acid gases collected in carbonate buffer solutions. 20 trace elements and 7 acid gases and acid aerosols were determined. Results were compared with those observed elsewhere and showed that air pollution is low in Kinshasa and does not give rise to anxieties. The main known sources of pollutants are: vehicle exhaust and aeolian process on stripped soils. (author). 13 refs, 2 figs, 6 tabs

  10. Arsenic speciation by hydride generation-quartz furnace atomic absorption spectrometry. Optimization of analytical parameters and application to environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Molenat, N.; Astruc, A.; Holeman, M.; Pinel, R. [Laboratoire de Chimie Analytique Bioinorganique et Environnement, Dept. de Chimie, Faculte des Sciences et Techniques, 64 - Pau (France); Maury, G. [Montpellier-2 Univ., 34 (France). Dept. de Chimie Organique Fine

    1999-11-01

    Analytical parameters of hydride generation, trapping, gas chromatography and atomic absorption spectrometry detection in a quartz cell furnace (HG/GC/QFAAS) device have been optimized in order to develop an efficient and sensitive method for arsenic compounds speciation. Good performances were obtained with absolute detection limits in the range of 0.1 - 0.5 ng for arsenite, arsenate, mono-methyl-arsonic acid (MMAA), dimethyl-arsinic acid (DMAA) and trimethyl-arsine oxide (TMAO). A pH selective reduction for inorganic arsenic speciation was successfully reported. Application to the accurate determination of arsenic compounds in different environmental samples was performed. (authors)

  11. Sequential determination of arsenic, selenium, antimony, and tellurium in foods via rapid hydride evolution and atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Fiorino, J.A.; Jones, J.W.; Capar, S.G.

    1976-01-01

    Analysis of acid digests of foods for As, Se, Sb, and Te was semiautomated. Hydrides generated by controlled addition of base stabilized NaBH 4 solution to acid digests are transported directly into a shielded, hydrogen (nitrogen diluted), entrained-air flame for atomic absorption spectrophotometric determination of the individual elements. The detection limits, based on 1 g of digested sample, are approximately 10 to 20 ng/g for all four elements. Measurement precision is 1 to 2 percent relative standard deviation for each element measured at 0.10 μg. A comparison is made of results of analysis of lyophilized fish tissues for As and Se by instrumental neutron activation (INAA), hydride generation with atomic absorption spectrometry, fluorometry, and spectrophotometry. NBS standard reference materials (orchard leaves and bovine liver) analyzed for As, Se, and Sb by this method show excellent agreement with certified values and with independent NAA values

  12. Standardization of digestion procedure for the determination of heavy metals in biological materials by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Khalid, N.; Chaudhri, S.A.

    1999-01-01

    Proper decomposition of the sample is one of the basic requirements of the atomic absorption spectroscopic analysis. In the present studies, heavy metals (Cu, Fe, Mn and Zn) were determined in biological samples by designating them in a mixture of nitric acid and perchloric acid. The quantification was made with atomic absorption spectrometry using an air-acetylene flame. The reliability of the procedure used was checked by analysing standard reference materials from NBS and IAEA, such as Rice flour (NBS-SRM-1568), Horse Kidney (IAEA H-8), Mixed Human diet(IAEA H-9), Copepod (IAEA MA-A-1) and fish flesh (IAEA MA-A-2) under identical conditions. A good agreement was observed between determined and the certified values reported by NBS and IAEA. (author)

  13. Arsenic in marine tissues - The challenging problems to electrothermal and hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Karadjova, Irina B.; Petrov, Panayot K. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria); Serafimovski, Ivan [Food Institute, Faculty of Veterinary Medicine, Sts. Cyril and Methodius University, P.O. Box 95, MK-1000, Skopje (Macedonia, The Former Yugoslav Republic of); Stafilov, Trajce [Institute of Chemistry, Faculty of Science, Sts. Cyril and Methodius University, P.O. Box 162, MK-1000, Skopje (Macedonia, The Former Yugoslav Republic of); Tsalev, Dimiter L. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria)], E-mail: tsalev@chem.uni-sofia.bg

    2007-03-15

    Analytical problems in determination of arsenic in marine tissues are addressed. Procedures for the determination of total As in solubilized or extracted tissues with tetramethylammonium hydroxide and methanol have been elaborated. Several typical lyophilized tissues were used: NIST SRM 1566a 'Oyster Tissue', BCR-60 CRM 'Trace Elements in an Aquatic Plant (Lagarosiphon major)', BCR-627 'Forms of As in Tuna Fish Tissue', IAEA-140/TM 'Sea Plant Homogenate', NRCC DOLT-1 'Dogfish Liver' and two representatives of the Black Sea biota, Mediterranean mussel (Mytilus galloprovincialis) and Brown algae (Cystoseira barbata). Tissues (nominal 0.3 g) were extracted in tetramethylammonium hydroxide (TMAH) 1 ml of 25% m/v TMAH and 2 ml of water) or 5 ml of aqueous 80% v/v methanol (MeOH) in closed vessels in a microwave oven at 50 deg. C for 30 min. Arsenic in solubilized or extracted tissues was determined by electrothermal atomic absorption spectrometry (ETAAS) after appropriate dilution (nominally to 25 ml, with further dilution as required) under optimal instrumental parameters (pyrolysis temperature 900 deg. C and atomization temperature 2100 deg. C) with 1.5 {mu}g Pd as modifier on Zr-Ir treated platform. Platforms have been pre-treated with 2.7 {mu}mol of zirconium and then with 0.10 {mu}mol of iridium which served as a permanent chemical modifier in direct ETAAS measurements and as an efficient hydride sequestration medium in flow injection hydride generation (FI-HG)-ETAAS. TMAH and methanol extract 96-108% and 51-100% of As from CRMs. Various calibration approaches have been considered and critically evaluated. The effect of species-dependent slope of calibration graph or standard additions plot for total As determination in a sample comprising of several individual As species with different ETAAS behavior has been considered as a kind of 'intrinsic element speciation interference' that cannot be completely

  14. Arsenic in marine tissues — The challenging problems to electrothermal and hydride generation atomic absorption spectrometry

    Science.gov (United States)

    Karadjova, Irina B.; Petrov, Panayot K.; Serafimovski, Ivan; Stafilov, Trajče; Tsalev, Dimiter L.

    2007-03-01

    Analytical problems in determination of arsenic in marine tissues are addressed. Procedures for the determination of total As in solubilized or extracted tissues with tetramethylammonium hydroxide and methanol have been elaborated. Several typical lyophilized tissues were used: NIST SRM 1566a 'Oyster Tissue', BCR-60 CRM 'Trace Elements in an Aquatic Plant ( Lagarosiphon major)', BCR-627 'Forms of As in Tuna Fish Tissue', IAEA-140/TM 'Sea Plant Homogenate', NRCC DOLT-1 'Dogfish Liver' and two representatives of the Black Sea biota, Mediterranean mussel ( Mytilus galloprovincialis) and Brown algae ( Cystoseira barbata). Tissues (nominal 0.3 g) were extracted in tetramethylammonium hydroxide (TMAH) 1 ml of 25% m/v TMAH and 2 ml of water) or 5 ml of aqueous 80% v/v methanol (MeOH) in closed vessels in a microwave oven at 50 °C for 30 min. Arsenic in solubilized or extracted tissues was determined by electrothermal atomic absorption spectrometry (ETAAS) after appropriate dilution (nominally to 25 ml, with further dilution as required) under optimal instrumental parameters (pyrolysis temperature 900 °C and atomization temperature 2100 °C) with 1.5 μg Pd as modifier on Zr-Ir treated platform. Platforms have been pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which served as a permanent chemical modifier in direct ETAAS measurements and as an efficient hydride sequestration medium in flow injection hydride generation (FI-HG)-ETAAS. TMAH and methanol extract 96-108% and 51-100% of As from CRMs. Various calibration approaches have been considered and critically evaluated. The effect of species-dependent slope of calibration graph or standard additions plot for total As determination in a sample comprising of several individual As species with different ETAAS behavior has been considered as a kind of 'intrinsic element speciation interference' that cannot be completely overcome by standard additions technique. Calibration by means of CRMs has

  15. Determination of Chlorine in Milk via Molecular Absorption of SrCl Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry.

    Science.gov (United States)

    Ozbek, Nil; Akman, Suleyman

    2016-07-20

    Total chlorine in milk was determined via the molecular absorption of diatomic strontium monochloride at 635.862 nm using high-resolution continuum source graphite furnace atomic absorption spectrometry. The effects of coating the graphite furnace, using different modifiers, amount of molecule-forming element, and different calibrants were investigated and optimized. Chlorine concentrations in milk samples were determined in a Zr-coated graphite furnace using 25 μg of Sr as the molecule-forming reagent and applying a pyrolysis temperature of 600 °C and a molecule-forming temperature of 2300 °C. Linearity was maintained up to 500 μg mL(-1) of Cl. The method was tested by analyzing a certified reference wastewater. The results were in the uncertainty limits of the certified value. The limit of detection of the method was 1.76 μg mL(-1). The chlorine concentrations in various cow milk samples taken from the market were found in the range of 588-1472 mg L(-1).

  16. Interference of nitrite and nitrogen dioxide on mercury and selenium determination by chemical vapor generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lopes Nunes, Dayana; Pereira dos Santos, Eliane Pereira; Barin, Juliano Smanioto; Mortari, Sergio Roberto; Dressler, Valderi Luiz; Moraes Flores, Erico Marlon de

    2005-01-01

    In this study, a systematic investigation was performed concerning the interference of nitrogen oxides on the determination of selenium and mercury by hydride generation atomic absorption spectrometry (HG AAS) and cold vapor atomic absorption spectrometry (CV AAS). The effect of nitrate, nitrite and NO 2 dissolved in the condensed phase was evaluated. No effect of NO 3 - on Se and Hg determination was observed up to 100 mg of sodium nitrate added to the reaction vessel. The Se signal was reduced by about 80% upon the addition of 6.8 mg NO 2 - . For Hg, no interference of nitrite was observed up to 20 mg of NO 2 - . A complete suppression of the Se signal was observed when gaseous NO 2 was introduced into analytical solutions. For Hg, a signal decrease between 8 and 13% occurred. For Se, bubbling argon or heating the solution was not able to recover the original absorbance values, whereas Hg signals were recovered with these procedures. When gaseous NO 2 was passed directly into the atomizer, Se signals decreased similarly to when NO 2 was bubbled in analytical solutions. The addition of urea, hydroxylamine hydrochloride and sulfamic acid (SA) was investigated to reduce the NO 2 effect in sample digests containing residual NO 2 , but only SA was effective in reducing the interference. Based on the results, it is possible to propose the use of SA to prevent interferences in Se and Hg determinations by HG AAS and CV AAS, respectively

  17. Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers

    Science.gov (United States)

    Abad, Carlos; Florek, Stefan; Becker-Ross, Helmut; Huang, Mao-Dong; Heinrich, Hans-Joachim; Recknagel, Sebastian; Vogl, Jochen; Jakubowski, Norbert; Panne, Ulrich

    2017-10-01

    Boron isotope amount ratios n(10B)/n(11B) have been determined by monitoring the absorption spectrum of boron monohydride (BH) in a graphite furnace using high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Bands (0 → 0) and (1 → 1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Clean and free of memory effect molecular spectra of BH were recorded. In order to eliminate the memory effect of boron, a combination of 2% (v/v) hydrogen gas in argon and 1% trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers was used. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, for the evaluated region of 437 nm, an accuracy of 0.15‰ is obtained as the average deviation from the isotope reference materials. Expanded uncertainties with a coverage factor of k = 2 range between 0.15 and 0.44‰. This accuracy and precision are compatible with those obtained by mass spectrometry for boron isotope ratio measurements.

  18. MERCURY QUANTIFICATION IN SOILS USING THERMAL DESORPTION AND ATOMIC ABSORPTION SPECTROMETRY: PROPOSAL FOR AN ALTERNATIVE METHOD OF ANALYSIS

    Directory of Open Access Journals (Sweden)

    Liliane Catone Soares

    2015-08-01

    Full Text Available Despite the considerable environmental importance of mercury (Hg, given its high toxicity and ability to contaminate large areas via atmospheric deposition, little is known about its activity in soils, especially tropical soils, in comparison with other heavy metals. This lack of information about Hg arises because analytical methods for determination of Hg are more laborious and expensive compared to methods for other heavy metals. The situation is even more precarious regarding speciation of Hg in soils since sequential extraction methods are also inefficient for this metal. The aim of this paper is to present a technique of thermal desorption associated with atomic absorption spectrometry, TDAAS, as an efficient tool for quantitative determination of Hg in soils. The method consists of the release of Hg by heating, followed by its quantification by atomic absorption spectrometry. It was developed by constructing calibration curves in different soil samples based on increasing volumes of standard Hg2+ solutions. Performance, accuracy, precision, and quantification and detection limit parameters were evaluated. No matrix interference was detected. Certified reference samples and comparison with a Direct Mercury Analyzer, DMA (another highly recognized technique, were used in validation of the method, which proved to be accurate and precise.

  19. Multi-wavelength thermal-lens spectrometry for high-accuracy measurements of absorptivities and quantum yields of photodegradation of a hemoprotein–lipid complex

    Directory of Open Access Journals (Sweden)

    Kseniya Tishchenko

    2017-09-01

    Full Text Available Accurate measurements of absorptivities and quantum yields of biochemical species under various conditions are an important task of applied photonics and analytical chemistry. In this work, we provide a comparison of the capabilities of thermal-lens spectrometry to measure these parameters of various samples. Measurements of relevant model substances, biologically active substituted 2-thiohydantoins and their complexes of copper(I,II and heme proteins (forms of hemoglobin and cytochrome c, showed negligible differences in apparent molar absorptivities for thermal-lens spectrometry and optical-absorption (spectrophotometric data. The values for tabletop and microscale thermal-lens measurements under batch conditions differ insignificantly. The precision of measurements of molar absorptivities by thermal-lens spectrometry is no less than in the case of spectrophotometry or the precision is even higher in the cases of low absorptivities. For cardiolipin–cytochrome c-NO complex, the difference between absorptivity values calculated from thermal-lens data and acquired by spectrophotometry is significant due to complex photodegradation. The quantum yield of its photolysis reaction calculated from optical absorption and thermal-lens data altogether at two wavelengths for 0.4–360 s of the reaction, 0.46 ± 0.04, was estimated.

  20. Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Dessuy, Morgana B.; Vale, Maria Goreti R.; Lepri, Fabio G.; Borges, Daniel L.G.; Welz, Bernhard; Silva, Marcia M.; Heitmann, Uwe

    2008-01-01

    The artifacts created in the measurement of phosphorus at the 213.6-nm non-resonance line by electrothermal atomic absorption spectrometry using line source atomic absorption spectrometry (LS AAS) and deuterium lamp background correction (D 2 BC) have been investigated using high-resolution continuum source atomic absorption spectrometry (HR-CS AAS). The absorbance signals and the analytical curves obtained by LS AAS without and with D 2 BC, and with HR-CS AAS without and with automatic correction for continuous background absorption, and also with least-squares background correction for molecular absorption with rotational fine structure were compared. The molecular absorption due to the suboxide PO that exhibits pronounced fine structure could not be corrected by the D 2 BC system, causing significant overcorrection. Among the investigated chemical modifiers, NaF, La, Pd and Pd + Ca, the Pd modifier resulted in the best agreement of the results obtained with LS AAS and HR-CS AAS. However, a 15% to 100% higher sensitivity, expressed as slope of the analytical curve, was obtained for LS AAS compared to HR-CS AAS, depending on the modifier. Although no final proof could be found, the most likely explanation is that this artifact is caused by a yet unidentified phosphorus species that causes a spectrally continuous absorption, which is corrected without problems by HR-CS AAS, but which is not recognized and corrected by the D 2 BC system of LS AAS

  1. Absorption coefficient of nearly transparent liquids measured using thermal lens spectrometry

    Directory of Open Access Journals (Sweden)

    H.Cabrera

    2006-01-01

    Full Text Available We use an optimized pump-probe mode-mismatched thermal lens scheme to determine the optical absorption coefficient and thermal diffusivity of ethanol, benzene, acetone, methanol, toluene and chloroform. In this scheme the excitation beam is focused in the presence of a collimated probe beam. The agreement between experimentally obtained results and values reported in the literature is good.

  2. Element selective detection of molecular species applying chromatographic techniques and diode laser atomic absorption spectrometry.

    Science.gov (United States)

    Kunze, K; Zybin, A; Koch, J; Franzke, J; Miclea, M; Niemax, K

    2004-12-01

    Tunable diode laser atomic absorption spectroscopy (DLAAS) combined with separation techniques and atomization in plasmas and flames is presented as a powerful method for analysis of molecular species. The analytical figures of merit of the technique are demonstrated by the measurement of Cr(VI) and Mn compounds, as well as molecular species including halogen atoms, hydrogen, carbon and sulfur.

  3. Assessment of cadmium and iron adsorption in sediment, employing a flow injection analysis system with on line filtration and detection by flame atomic absorption spectrometry and thermospray flame furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Fagner Moreira de; Marchioni, Camila; Barros, Juan A. V de A. [Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Rua GabrielMonteiro da Silva, 714, CEP 37130-000, Alfenas-MG (Brazil); Lago, Ayla Campos do [Universidade Federal de São Carlos (UFSCar-SP), Departamento de Química, 10Rodovia Washington Luís, Km 235-SP 310, CEP 16565-905, São Carlos-SP (Brazil); Wisniewski, Célio [Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Rua GabrielMonteiro da Silva, 714, CEP 37130-000, Alfenas-MG (Brazil); Luccas, Pedro Orival, E-mail: pedro.luccas@unifal-mg.edu.br [Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Rua GabrielMonteiro da Silva, 714, CEP 37130-000, Alfenas-MG (Brazil)

    2014-01-27

    Graphical abstract: -- Highlights: •A FIA system with on-line filtration for isotherms adsorption studies was proposed. •Isotherms for iron and cadmium elements in bottom lake sediment were done. •Inferences about adsorption/desorption mechanisms were feasible. •The proposed method turns the isotherm studies fast and reliable. -- Abstract: This work presents an evaluation of iron and cadmium adsorption in sediment of the Furnas Hydroelectric Plant Reservatory located in Alfenas, Minas Gerais (Brazil). The metal determination was done employing a flow injection analysis (FIA) with an on-line filtering system. As detection techniques, flame atomic absorption spectrometry (FAAS) for iron and thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determinations were used. The developed methodology presented good limits of detection, being 190 μg L{sup −1} for iron and 1.36 μg L{sup −1} for cadmium, and high sampling frequency for both metals 144 and 60 readings h{sup −1} for iron and cadmium, respectively. Both metals obey the Langmuir model, with maximum adsorptive capacity of 0⋅169 mg g{sup −1} for iron and 7⋅991 mg g{sup −1} for cadmium. For iron, a pseudo-first-order kinetic model was obtained with a theoretical Q{sub e} = 9⋅8355 mg g{sup −1} (experimental Q{sub e} = 9⋅5432 mg g{sup −1}), while for cadmium, a pseudo-second-order kinetic model was obtained, with a theoretical Q{sub e} = 0.3123 mg g{sup −1} (experimental Q{sub e} = 0⋅3052 mg g{sup −1})

  4. Diagnostics of reactive pulsed plasmas by UV and VUV absorption spectroscopy and by modulated beam Mass spectrometry

    Science.gov (United States)

    Cunge, Gilles

    2011-10-01

    Pulsed plasmas are promising for etching applications in the microelectronic industry. However, many new phenomena are involved when a high density discharge is pulsed. To better understand these processes it is necessary to probe the radicals' kinetics with a microsecond resolution. We have developed several diagnostics to reach this goal including broad band absorption spectroscopy with UV LEDs to detect small polyatomic radicals and with a deuterium VUV source to detect larger closed shell molecules and the modulated mass spectrometry to monitor atomic species. We will discuss the impact of the plasma pulsing frequency and duty cycle on the radical densities in Cl2 based plasmas, and the consequences on plasma processes. Work done in collaboration with Paul Bodart, Melisa Brihoum, Maxime Darnon, Erwin Pargon, Olivier Joubert, and Nader Sadeghi, CNRS/LTM.

  5. Performance of permanent iridium modifier in the presence of corrosive matrix in graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Piascik, M.; Bulska, E. [Univ. of Warsaw (Poland). Dept. of Chemistry

    2001-12-01

    The influence of up to 16% HNO{sub 3}, 28% HCl, and the mixture of both acids in aqua regia on the analytical performance of electrodeposited modifiers (Ir or Ir+Pd) was evaluated and discussed. Cadmium was used as an example of volatile elements often determined by graphite furnace atomic absorption spectrometry (GF AAS). In the presence of HCl, the maximum pyrolysis temperature that could be applied was found to be 600 C. In the presence of HNO{sub 3} and aqua regia, both modifiers stabilized cadmium up to 800 C. The long-term performance of electrodeposited Ir or Ir+Pd was not influenced by mineral acids; moreover the tube lifetime was significantly prolonged compared with a non-modified tube. (orig.)

  6. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  7. Study of 249BkBr3 dimorphism by absorption spectrometry and X ray diffraction

    International Nuclear Information System (INIS)

    Peterson, J.R.; Fellows, R.L.; Young, J.P.; Haire, R.G.

    1977-01-01

    The phase transformation that occurs in solid BkBr 3 was studied by absorption spectroscopy and X-ray diffraction. Both techniques were applied to each 2-12 microgram sample at ambient and elevated temperatures. Significant increases in the f-f transition intensities were observed when the crystal structure was changed from the AlCl 3 -type monoclinic to the PuBr 3 -type orthorhombic form. The high-temperature monoclinic form can be maintained at room temperature by quenching the sample from above 350 deg C. By following the absorption intensity changes, it is also possible to study the kinetics of the phase transformation in the temperature range of 200-350 deg C [fr

  8. Data Processing Algorithm for Diagnostics of Combustion Using Diode Laser Absorption Spectrometry.

    Science.gov (United States)

    Mironenko, Vladimir R; Kuritsyn, Yuril A; Liger, Vladimir V; Bolshov, Mikhail A

    2018-02-01

    A new algorithm for the evaluation of the integral line intensity for inferring the correct value for the temperature of a hot zone in the diagnostic of combustion by absorption spectroscopy with diode lasers is proposed. The algorithm is based not on the fitting of the baseline (BL) but on the expansion of the experimental and simulated spectra in a series of orthogonal polynomials, subtracting of the first three components of the expansion from both the experimental and simulated spectra, and fitting the spectra thus modified. The algorithm is tested in the numerical experiment by the simulation of the absorption spectra using a spectroscopic database, the addition of white noise, and the parabolic BL. Such constructed absorption spectra are treated as experimental in further calculations. The theoretical absorption spectra were simulated with the parameters (temperature, total pressure, concentration of water vapor) close to the parameters used for simulation of the experimental data. Then, spectra were expanded in the series of orthogonal polynomials and first components were subtracted from both spectra. The value of the correct integral line intensities and hence the correct temperature evaluation were obtained by fitting of the thus modified experimental and simulated spectra. The dependence of the mean and standard deviation of the evaluation of the integral line intensity on the linewidth and the number of subtracted components (first two or three) were examined. The proposed algorithm provides a correct estimation of temperature with standard deviation better than 60 K (for T = 1000 K) for the line half-width up to 0.6 cm -1 . The proposed algorithm allows for obtaining the parameters of a hot zone without the fitting of usually unknown BL.

  9. Introduction of Flame Atomic Absorption Spectrometry (FAAS) For River Water Samples Analysis

    International Nuclear Information System (INIS)

    Shakirah Abd Shukor; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman

    2015-01-01

    Metal contamination in water is a major component in the determination of water quality monitoring. In spite of the viability of several other metal ion analysis techniques for river water, atomic absorption spectroscopy (AAS) method is most commonly used due to the reproducibility results, short analysis time, cost effective, lower level detection and robust. Therefore, this article gives an overview on the principles, instrumentation techniques, sample preparations, instrument calibration and data analysis in a simple manner for beginner. (author)

  10. Monitoring of Pd in airborne particulates by solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Atilgan, Semin [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak, Istanbul (Turkey); Akman, Suleyman, E-mail: akmans@itu.edu.tr [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak, Istanbul (Turkey); Baysal, Asli [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak, Istanbul (Turkey); Bakircioglu, Yasemin [Trakya University, Faculty of Science and Letters, Department of Chemistry, 22030, Edirne (Turkey); Szigeti, Tamas; Ovari, Mihaly; Zaray, Gyula [Eoetvoes Lorand University, Institute of Chemistry, Department of Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)

    2012-04-15

    An analytical method has been developed for determination of palladium in PM2.5 fractions of urban airborne particulate matter by solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry. For the optimization of the experimental conditions, a road dust certified reference material (BCR-723) was used. The influence of pyrolysis and atomization temperatures, the amount of sample introduced into the graphite furnace and the addition of acids, surfactants and modifiers on the analytical signal of Pd were investigated. The limit of detection, calculated based on three times the standard deviations of analytical signals obtained during the atomization of 10 blank filter pieces, was 0.07 pg/m{sup 3}. Since the amount of solid certified reference material introduced into the graphite furnace was about 50-2000 times lower than those required in order to obtain the certified value, the precision was relatively poor. This analytical method was applied for investigation of urban airborne particulate matter collected onto quartz fiber filters by high-volume aerosol samplers in the city center of Istanbul (Turkey) and Budapest (Hungary). The measured Pd concentrations changed in the range of 0.22-0.64 and 0.25-0.86 pg/m{sup 3} in Istanbul and Budapest, respectively. - Highlights: Black-Right-Pointing-Pointer Method development for palladium determination in air samples using solid sampling technique. Black-Right-Pointing-Pointer Analysis by solid sampling electrothermal atomic absorption spectrometry (HR CS ETAAS). Black-Right-Pointing-Pointer Monitoring of Pd in Istanbul and Budapest PM2.5 urban aerosols during one year. Black-Right-Pointing-Pointer Statistical analysis of results.

  11. Application of Plackett-Burman and Doehlert designs for optimization of selenium analysis in plasma with electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    El Ati-Hellal, Myriam; Hellal, Fayçal; Hedhili, Abderrazek

    2014-10-01

    The aim of this study was the optimization of selenium determination in plasma samples with electrothermal atomic absorption spectrometry using experimental design methodology. 11 variables being able to influence selenium analysis in human blood plasma by electrothermal atomic absorption spectrometry (ETAAS) were evaluated with Plackett-Burman experimental design. These factors were selected from sample preparation, furnace program and chemical modification steps. Both absorbance and background signals were chosen as responses in the screening approach. Doehlert design was used for method optimization. Results showed that only ashing temperature has a statistically significant effect on the selected responses. Optimization with Doehlert design allowed the development of a reliable method for selenium analysis with ETAAS. Samples were diluted 1/10 with 0.05% (v/v) TritonX-100+2.5% (v/v) HNO3 solution. Optimized ashing and atomization temperatures for nickel modifier were 1070°C and 2270°C, respectively. A detection limit of 2.1μgL(-1) Se was obtained. Accuracy of the method was checked by the analysis of selenium in Seronorm™ Trace element quality control serum level 1. The developed procedure was applied for the analysis of total selenium in fifteen plasma samples with standard addition method. Concentrations ranged between 24.4 and 64.6μgL(-1), with a mean of 42.6±4.9μgL(-1). The use of experimental designs allowed the development of a cheap and accurate method for selenium analysis in plasma that could be applied routinely in clinical laboratories. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry.

    Science.gov (United States)

    Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel

    2014-08-13

    A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.

  13. High-resolution continuum source electrothermal atomic absorption spectrometry - An analytical and diagnostic tool for trace analysis

    International Nuclear Information System (INIS)

    Welz, Bernhard; Borges, Daniel L.G.; Lepri, Fabio G.; Vale, Maria Goreti R.; Heitmann, Uwe

    2007-01-01

    The literature about applications of high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) with electrothermal atomization is reviewed. The historic development of HR-CS AAS is briefly summarized and the main advantages of this technique, mainly the 'visibility' of the spectral environment around the analytical line at high resolution and the unequaled simultaneous background correction are discussed. Simultaneous multielement CS AAS has been realized only in a very limited number of cases. The direct analysis of solid samples appears to have gained a lot from the special features of HR-CS AAS, and the examples from the literature suggest that calibration can be carried out against aqueous standards. Low-temperature losses of nickel and vanadyl porphyrins could be detected and avoided in the analysis of crude oil due to the superior background correction system. The visibility of the spectral environment around the analytical line revealed that the absorbance signal measured for phosphorus at the 213.6 nm non-resonance line without a modifier is mostly due to the PO molecule, and not to atomic phosphorus. The future possibility to apply high-resolution continuum source molecular absorption for the determination of non-metals is discussed

  14. Determination of total sulfur in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry.

    Science.gov (United States)

    Virgilio, Alex; Raposo, Jorge L; Cardoso, Arnaldo A; Nóbrega, Joaquim A; Gomes Neto, José A

    2011-03-23

    The usefulness of molecular absorption was investigated for the determination of total sulfur (S) in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry. The lines for CS at 257.595, 257.958, and 258.056 nm and for SH at 323.658, 324.064, and 327.990 nm were evaluated. Figures of merit, such as linear dynamic range, sensitivity, linear correlation, characteristic concentration, limit of detection, and precision, were established. For selected CS lines, wavelength-integrated absorbance equivalent to 3 pixels, analytical curves in the 100-2500 mg L(-1) (257.595 nm), 250-2000 mg L(-1) (257.958 nm), and 250-5000 mg L(-1) (258.056 nm) ranges with a linear correlation coefficient better than 0.9980 were obtained. Results were in agreement at a 95% confidence level (paired t test) with those obtained by gravimetry. Recoveries of S in fungicide and fertilizer samples were within the 84-109% range, and the relative standard deviation (n=12) was typically <5%.

  15. Surfactant/oil/water system for the determination of selenium in eggs by graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Ieggli, C. V. S.; Bohrer, D.; Noremberg, S.; do Nascimento, P. C.; de Carvalho, L. M.; Vieira, S. L.; Reis, R. N.

    2009-06-01

    An oil-in-water formulation has been optimized to determine trace levels of selenium in whole hen eggs by graphite furnace atomic absorption spectrometry. This method is simpler and requires fewer reagents when compared with other sample pre-treatment procedures. Graphite furnace atomic absorption spectrometric (GF AAS) measurement was carried out using standard addition calibration and Pd as a modifier. The precision, expressed as relative standard deviation, was better than 5% and the limit of detection was 1 µg L - 1 . The validation of the method was performed against a standard reference material Whole Egg Powder (RM 8415), and the measured Se corresponded to 95.2% of the certified value. The method was used for the determination of the Se level in eggs from hens treated with Se dietary supplements. Inorganic and organic Se sources were added to hen feed. The Se content of eggs was higher when hens were fed with organic Se compared to the other treatments. The proposed method, including sample emulsification for subsequent Se determination by GF AAS has proved to be sensitive, reproducible, simple and economical.

  16. Surfactant/oil/water system for the determination of selenium in eggs by graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ieggli, C.V.S. [Departamento de Quimica, Avenida Roraima, 1000, Universidade Federal de Santa Maria, CEP 97110-970, Santa Maria, RS (Brazil); Bohrer, D. [Departamento de Quimica, Avenida Roraima, 1000, Universidade Federal de Santa Maria, CEP 97110-970, Santa Maria, RS (Brazil)], E-mail: ndenise@quimica.ufsm.br; Noremberg, S.; Nascimento, P.C. do; Carvalho, L.M. de [Departamento de Quimica, Avenida Roraima, 1000, Universidade Federal de Santa Maria, CEP 97110-970, Santa Maria, RS (Brazil); Vieira, S.L.; Reis, R.N. [Faculdade de Agronomia, Universidade Federal do Rio Grande do Sul, Av. Bento Goncalves, 7712, CEP 90540-000, Porto Alegre (Brazil)

    2009-06-15

    An oil-in-water formulation has been optimized to determine trace levels of selenium in whole hen eggs by graphite furnace atomic absorption spectrometry. This method is simpler and requires fewer reagents when compared with other sample pre-treatment procedures. Graphite furnace atomic absorption spectrometric (GF AAS) measurement was carried out using standard addition calibration and Pd as a modifier. The precision, expressed as relative standard deviation, was better than 5% and the limit of detection was 1 {mu}g L{sup - 1}. The validation of the method was performed against a standard reference material Whole Egg Powder (RM 8415), and the measured Se corresponded to 95.2% of the certified value. The method was used for the determination of the Se level in eggs from hens treated with Se dietary supplements. Inorganic and organic Se sources were added to hen feed. The Se content of eggs was higher when hens were fed with organic Se compared to the other treatments. The proposed method, including sample emulsification for subsequent Se determination by GF AAS has proved to be sensitive, reproducible, simple and economical.

  17. Human Vitamin B12 Absorption and Metabolism are Measured by Accelerator Mass Spectrometry Using Specifically Labeled 14C-Cobalamin

    International Nuclear Information System (INIS)

    Carkeet, C; Dueker, S R; Lango, J; Buchholz, B A; Miller, J W; Green, R; Hammock, B D; Roth, J R; Anderson, P J

    2006-01-01

    There is need for an improved test of human ability to assimilate dietary vitamin B 12 . Assaying and understanding absorption and uptake of B 12 is important because defects can lead to hematological and neurological complications. Accelerator mass spectrometry (AMS) is uniquely suited for assessing absorption and kinetics of 14 C-labeled substances after oral ingestion because it is more sensitive than decay counting and can measure levels of carbon-14 ( 14 C) in microliter volumes of biological samples, with negligible exposure of subjects to radioactivity. The test we describe employs amounts of B 12 in the range of normal dietary intake. The B 12 used was quantitatively labeled with 14 C at one particular atom of the DMB moiety by exploiting idiosyncrasies of Salmonellametabolism. In order to grow aerobically on ethanolamine, S. entericamust be provided with either pre-formed B 12 or two of its precursors: cobinamide and dimethylbenzimidazole (DMB). When provided with 14 C-DMB specifically labeled in the C2 position, cells produced 14 C-B 12 of high specific activity (2.1 GBq/mmol, 58 mCi/mmol) and no detectable dilution of label from endogenous DMB synthesis. In a human kinetic study, a physiological dose (1.5 mg, 2.2 KBq/59 nCi) of purified 14 C-B 12 was administered and showed plasma appearance and clearance curves consistent with the predicted behavior of the pure vitamin. This method opens new avenues for study of B 12 assimilation

  18. Determination of sulfur in coal and ash slurry by high-resolution continuum source electrothermal molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nakadi, Flávio V.; Rosa, Lilian R.; Veiga, Márcia A.M.S. da, E-mail: mamsveiga@ffclrp.usp.br

    2013-10-01

    We propose a procedure for the determination of sulfur in coal slurries by high resolution continuum source electrothermal molecular absorption spectrometry. The slurry, whose concentration is 1 mg mL{sup −1}, was prepared by mixing 50 mg of the sample with 5% v/v nitric acid and 0.04% m/v Triton X-100 and was homogenized manually. It sustained good stability. The determination was performed via CS molecular absorption at 257.592 nm, and the optimized vaporization temperature was 2500 °C. The accuracy of the method was ensured by analysis of certified reference materials SRM 1632b (trace elements in coal) and SRM 1633b (coal fly ash) from the National Institute of Standards and Technology, using external calibration with aqueous standards prepared in the same medium and used as slurry. We achieved good agreement with the certified reference materials within 95% confidence interval, LOD of 0.01% w/w, and RSD of 6%, which confirms the potential of the proposed method. - Highlights: • HR-CS ET MAS as a technique to determine sulfur in coal and ash • Utilization of (coal and coal fly ash) slurry as a sample preparation • Simple and fast method, which uses external calibration with aqueous standards without chemical modifier.

  19. Determination of vanadium in sea water by graphite furnace atomic absorption spectrometry with a tube coated with pyrolytic graphite

    International Nuclear Information System (INIS)

    Shimizu, Tokuo; Sakai, Kaoru

    1981-01-01

    The trace amount of vanadium in sea water was determined by graphite furnace atomic absorption spectrometry with a tube coated with pyrolytic graphite. To correct the background absorption, a deuterium lamp with a higher-brilliant thermal cathode was used. The sensitivity for vanadium increased 10 -- 20 fold by the use of the tube coated with pyrolytic graphite, and the utility lifetime of the tube was greatly extended. Vanadium(V) - 4-(2-pyridylazo)resorcinol (PAR) complexes were extracted into chloroform as an ion-pair with benzyldimethyltetradecylammonium (Zephiramine) cation alternatively. The sample of sea water, which was made to 0.1 N in sulfuric acid and 0.1% in hydrogen peroxide, was loaded onto the column of Dowex 1-X 4 resin (SO 4 2- -form). Vanadium was then eluted from the resin with 1 N sulfuric acid-0.1% hydrogen peroxide or 1 N hydrochloric acid-0.1% hydrogen peroxide evaporated to dry. After dissolution of the elute in 0.2 N nitric acid, vanadium was extracted. Secondly, the sample of sea water was adjusted to pH 5.0, and loaded onto the column of Chelex-100 resin. Vanadium was eluted from the resin with 2 N ammonia. The above two methods took much time, but the coprecipitation method was not so and recommended for the determination of vanadium in sea water. Vanadium was coprecipitated with iron(III) hydroxide-hydrous titanium(IV) oxide at pH 6.0. The precipitate was digested with nitric acid-hydrogen peroxide. The solution was diluted to 50 ml with water. The resulting solutions were employed to determine the vanadium concentration by the graphite furnace atomic absorption measurement. The trace amounts of vanadium in various kinds of the coastal sea water were determined by the coprecipitation method. (author)

  20. Determination of sulphur in various vegetables by solid sampling high-resolution electrothermal molecular absorption spectrometry.

    Science.gov (United States)

    Gunduz, Sema; Akman, Suleyman

    2015-04-01

    Sulphur was determined in various vegetables via molecular absorption of carbon monosulphide (CS) at 258.056 nm using a solid sampling high resolution continuum source electrothermal atomic absorption spectrometer (SS HR-CS ETAAS). Samples were dried, ground and directly introduced into the ruthenium coated graphite furnace as 0.05 to 0.50mg. All determinations were performed using palladium+citric acid modifier and applying a pyrolysis temperature of 1000 °C and a volatilisation temperature of 2400 °C. The results were in good agreement with certified sulphur concentrations of various vegetal CRM samples applying linear calibration technique prepared from thioacetamide. The limit of detection and characteristic mass of the method were 7.5 and 8.7 ng of S, respectively. The concentrations of S in various spinach, leek, lettuce, radish, Brussels sprouts, zucchini and chard samples were determined. It was showed that distribution of sulphur in CRM and grinded food samples were homogeneous even in micro-scale. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Separation of seven arsenic compounds by high-performance liquid chromatography with on-line detection by hydrogen–argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, E. H.; Pritzl, G.

    1992-01-01

    Seven molecular forms of arsenic were separated by anion- and cation-exchange high-performance liquid chromatography (HPLC) with on-line detection by flame atomic absorption spectrometry (FAAS). The interfacing was established by a vented poly(tetrafluoroethylene) capillary tubing connecting the ...

  2. Speciation of arsenic(III)/arsenic(V) and selenium(IV)/ selenium(VI) using coupled ion chromatography - hydride generation atomic absorption spectrometry

    Science.gov (United States)

    Simple analytical methods have been developed to speciate inorganic arsenic and selenium in the ppb range using coupled ion chromatography-hydride generation atomic absorption spectrometry. Because of the differences in toxicity and adsorption behavior, determinations of the redox states arsenite A...

  3. Accuracy of a method based on atomic absorption spectrometry to determine inorganic arsenic in food: Outcome of the collaborative trial IMEP-41

    DEFF Research Database (Denmark)

    Fiamegkos, I.; Cordeiro, F.; Robouch, P.

    2016-01-01

    the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry...

  4. Determination of bismuth by dielectric barrier discharge atomic absorption spectrometry coupled with hydride generation: Method optimization and evaluation of analytical performance

    Czech Academy of Sciences Publication Activity Database

    Kratzer, Jan; Boušek, J.; Sturgeon, R. E.; Mester, Z.; Dědina, Jiří

    2014-01-01

    Roč. 86, č. 19 (2014), s. 9620-9625 ISSN 0003-2700 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation * atomic absorption spectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.636, year: 2014

  5. Investigations into the Role of Modifiers for Entrapment of Hydrides in Flow Injection Hydride Generation Electrothermal Atomic Absorption Spectrometry as Exemplified for the Determination of Germanium

    DEFF Research Database (Denmark)

    Hilligsøe, Bo; Andersen, Jens Enevold Thaulov; Hansen, Elo Harald

    1997-01-01

    Pd-conditioned graphite tubes, placed in the furnace of an atomic absorption spectrometry instrument, are used for entrapment of germane as generated in an associated flow injection system. Two different approaches are tested with the ultimate aim to allow multiple determinations, that is...

  6. Selective Flow Injection Analysis of Ultra-trace Amounts of Cr(VI), Preconcentration of It by Solvent Extraction, and Determination by Electrothermal Atomic Absorption Spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Sturup, Stefan; Spliid, Henrik

    1999-01-01

    A rapid, robust, sensitive and selective time-based flow injection (FI) on-line solvent extraction system interfaced with electrothermal atomic absorption spectrometry (ETAAS) is described for analyzing ultra-trace amounts of Cr(VI). The sample is initially mixed on-line with isobutyl methyl ketone...

  7. On-line determination of manganese in solid seafood samples by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yebra, M.C.; Moreno-Cid, A.

    2003-01-01

    Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g -1 manganese (dry mass). The detection limit is 0.4 μg g -1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples

  8. Determination of trace amounts of tin in geological materials by atomic absorption spectrometry

    Science.gov (United States)

    Welsch, E.P.; Chao, T.T.

    1976-01-01

    An atomic absorption method is described for the determination of traces of tin in rocks, soils, and stream sediments. A dried mixture of the sample and ammonium iodide is heated to volatilize tin tetraiodide -which is then dissolved in 5 % hydrochloric acid, extracted into TOPO-MIBK, and aspirated into a nitrous oxide-acetylene flame. The limit of determination is 2 p.p.m. tin and the relative standard deviation ranges from 2 to 14 %. Up to 20 % iron and 1000 p.p.m. Cu, Pb, Zn, Mn, Hg, Mo, V, or W in the sample do not interfere. As many as 50 samples can be easily analyzed per man-day. ?? 1976.

  9. Arsenic Speciation of Waters from the Aegean Region, Turkey by Hydride Generation: Atomic Absorption Spectrometry.

    Science.gov (United States)

    Çiftçi, Tülin Deniz; Henden, Emur

    2016-08-01

    Arsenic in drinking water is a serious problem for human health. Since the toxicity of arsenic species As(III) and As(V) is different, it is important to determine the concentrations separately. Therefore, it is necessary to develop an accurate and sensitive method for the speciation of arsenic. It was intended with this work to determine the concentrations of arsenic species in water samples collected from Izmir, Manisa and nearby areas. A batch type hydride generation atomic absorption spectrometer was used. As(V) gave no signal under the optimal measurement conditions of As(III). A certified reference drinking water was analyzed by the method and the results showed excellent agreement with the reported values. The procedure was applied to 34 water samples. Eleven tap water, two spring water, 19 artesian well water and two thermal water samples were analyzed under the optimal conditions.

  10. Direct sampling graphite furnace atomic absorption spectrometry - feasibility of Na and K determination in desalted crude oil

    Science.gov (United States)

    Seeger, Tassia S.; Machado, Eduarda Q.; Flores, Erico M. M.; Mello, Paola A.; Duarte, Fabio A.

    2018-03-01

    In this study, Na and K were determined in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS), with the use of a Zeeman-effect background correction system with variable magnetic field. The analysis was performed in low and high sensitivity conditions. Sodium determination was performed in two low-sensitivity conditions: 1) main absorption line (589.0 nm), gas stop flow during the atomization step and 3-field dynamic mode (0.6-0.8 T); and 2) secondary absorption line (330.3 nm), gas stop flow during the atomization and 2-field mode (0.8 T). In K determination, some parameters, such as high-sensitivity mode, main absorption line (766.5 nm), gas stop flow during the atomization and 2-field mode (0.8 T), were used. Suitability of chemical modifiers, such as Pd and W-Ir was also evaluated. The heating program for Na and K was based on the pyrolysis and atomization curves. Calibration was performed by aqueous standards. Accuracy was evaluated by the analysis of Green Petroleum Coke (SRM NIST 2718) and Trace Elements in Fuel Oil (SRM NIST 1634c). Recovery tests were also performed and results were compared with those obtained by GF AAS after crude oil digestion by microwave-assisted digestion. The characteristic mass of Na was 17.1 pg and 0.46 ng in conditions 1 and 2, respectively, while the one of K was 1.4 pg. Limits of detection and quantification by DS-GF AAS were 30 and 40 ng g-1 for Na and 3.2 and 4.2 ng g-1 for K, respectively. Sodium and K were determined in three crude oil samples with API density ranging from 20.9 to 28.0. Sodium and K concentration ranged from 1.5 to 73 μg g-1 and from 23 to 522 ng g-1, respectively.

  11. Application of gamma ray spectrometry and atomic absorption spectrometry for monitoring some radionuclides and heavy metals in sediments from the sudanese red sea coast

    International Nuclear Information System (INIS)

    Idris, A. M.; Eltayeb, M. A.

    2004-01-01

    A total of 31 surface sediment samples were collected from port-sudan harbour, sawakin harbour and the fringing reefs area that are located along the Sudanese coast of the red sea. The sampling was performed to provide good spatial coverage taking into account man's activity in port-sudan harbour and the fringing reefs area. the bulk samples were analyzed for some natural and anthropogenic radionuclides ( 226 Ra, 228 Ra, 40 K, 137 Cs) using direct gamma-ray spectrometry. Concentration of some heavy metals were determined in five fractions with grain-size of 1.000-0.500 m lm, 0.500-0.250 m lm, 0.250-0.125 m lm, 0.125-0.063 m lm and less than 0.063 m lm. The fractionation process was performed using dry sieving method. A total of 155 sub-samples (fractions) were digested by wet digestion method and analyzed for Mn, Fe, Ni, Cu, Zn, and Pb using flame atomic absorption spectrometry. Quality assurance of the obtained data was achieved through the analysis of certified reference materials. the radioactivity concentration ranges of ( 226 Ra, 228 Ra, and 40 K,) are 2.5-25.1b/kg, 2.1-13.1b q/kg,21.6- 429 Bq/kg, respectively. For ( 137 Cs)measurements, the highest value is 8.3 Bq/kg while most of samples were below the detection limits of the system. The concentration ranges of Mn, Fe, Cu, Zn, and Pb are 53.3-819 mg/kg, 1.4-51 mg/g, 8-131 mg/kg 9.5-113 mg/kg, 18.4-142 mg/kg, and 4.0-26.6 mg/kg, respectively. The granulometric normalization shows that some samples were subjected to anthropogenic activities. This finding was reinforced by results that were obtained from enrichment factor calculations and statistical multivariate analysis that is principal component analysis (Pca), also the Pca indicates that silt/clay fraction (>0.063 m lm ) is the dominant source for the emission of anthropogenic activities. From viewpoint of mineralogical composition the cluster analysis has distributed the samples into tow clusters. Dominant elements in sediments (Mn and Fe ) recorded

  12. [Efficiency of hemoperfusion on clearing thallium based on atomic absorption spectrometry].

    Science.gov (United States)

    Tian, Tian; Wang, Yongan; Nie, Zhiyong; Wang, Jiao; Peng, Xiaobo; Yuan, Ye; Li, Wanhua; Qiu, Zewu; Xue, Yanping; Xiong, Yiru

    2015-04-01

    To determine thallium in whole blood by atomic absorption detection method, and to investigate the eliminating effect of hemoperfusion (HP) for thallium in blood. The blood of Beagle dogs which had not exposed to thallium before were obtained for preparation of thallium nitrate ( TlNO3 )-containing solution in three concentrations according to the conversion formula based on animal weight and volume of blood. HP was performed in the simulated in vivo environment. The content of TlNO3 in blood of the next group was determined on the amount of TlNO3 for the last HP of the former dose group. Thallium quantity in different samples was measured with atomic absorption spectrometer blood samples before and after HP. Finally, the thallium concentration in blood was analyzed statistically. Thallium concentrations showed a good linear relationship in the range of 0-200 μg/L (r = 0.998 4). The intra-day precision (RSD) was lower than 4.913%, the intra-day recovery rate was 96.2%-111.9%; the inter-day precision (RSD) was lower than 7.502%, the inter-day recovery rate was 89.6%-105.2%. The concentration of thallium in blood was significantly reduced after HP per time in high, middle, and low dose groups [(453.43 ± 27.80) mg/L to (56.09 ± 14.44) mg/L in high dose group, F = 8.820, P = 0.003; (64.51 ± 13.60) mg/L to (3.19 ± 0.23) mg/L in middle dose group, F = 36.312, P = 0.000; (5.40 ± 0.98) mg/L to (0.38 ± 0.25) mg/L in low dose group, F = 46.240, P = 0.000 ]. The adsorption rate of four times of HP in high, middle and low dose group were (87.63 ± 2.48 )%, (95.06 ± 1.54 )% and (92.76 ± 4.87)%, respectively, without significant difference (F = 4.231, P = 0.070). The method for measuring thallium was established, and it shows a very stable, simple, sensitive for determination of thallium. HP can effectively remove thallium from blood. Thallium concentration can be reduced by 90% after four times of HP. HP is also effective even when thallium concentration is not high.

  13. Determination of total tin in silicate rocks by graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Elsheimer, H.N.; Fries, T.L.

    1990-01-01

    A method is described for the determination of total tin in silicate rocks utilizing a graphite furnace atomic absorption spectrometer with a stabilized-temperature platform furnace and Zeeman-effect background correction. The sample is decomposed by lithium metaborate fusion (3 + 1) in graphite crucibles with the melt being dissolved in 7.5% hydrochloric acid. Tin extractions (4 + 1 or 8 + 1) are executed on portions of the acid solutions using a 4% solution of tricotylphosphine oxide in methyl isobutyl ketone (MIBK). Ascorbic acid is added as a reducing agent prior to extraction. A solution of diammonium hydrogenphosphate and magnesium nitrate is used as a matrix modifier in the graphite furnace determination. The limit of detection is > 10 pg, equivalent to > 1 ??g l-1 of tin in the MIBK solution or 0.2-0.3 ??g g-61 in the rock. The concentration range is linear between 2.5 and 500 ??g l-1 tin in solution. The precision, measured as relative standard deviation, is < 20% at the 2.5 ??g l-1 level and < 7% at the 10-30 ??g l-1 level of tin. Excellent agreement with recommended literature values was found when the method was applied to the international silicate rock standards BCR-1, PCC-1, GSP-1, AGV-1, STM-1, JGb-1 and Mica-Fe. Application was made to the determination of tin in geological core samples with total tin concentrations of the order of 1 ??g g-1 or less.

  14. Sample preparation for arsenic speciation analysis in baby food by generation of substituted arsines with atomic absorption spectrometry detection.

    Science.gov (United States)

    Huber, Charles S; Vale, Maria Goreti R; Dessuy, Morgana B; Svoboda, Milan; Musil, Stanislav; Dědina, Jiři

    2017-12-01

    A slurry sampling procedure for arsenic speciation analysis in baby food by arsane generation, cryogenic trapping and detection with atomic absorption spectrometry is presented. Several procedures were tested for slurry preparation, including different reagents (HNO 3 , HCl and tetramethylammonium hydroxide - TMAH) and their concentrations, water bath heating and ultrasound-assisted agitation. The best results for inorganic arsenic (iAs) and dimethylarsinate (DMA) were reached when using 3molL -1 HCl under heating and ultrasound-assisted agitation. The developed method was applied for the analysis of five porridge powder and six baby meal samples. The trueness of the method was checked with a certified reference material (CRM) of total arsenic (tAs), iAs and DMA in rice (ERM-BC211). Arsenic recoveries (mass balance) for all samples and CRM were performed by the determination of the tAs by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted digestion and its comparison against the sum of the results from the speciation analysis. The relative limits of detection were 0.44, 0.24 and 0.16µgkg -1 for iAs, methylarsonate and DMA, respectively. The concentrations of the most toxic arsenic species (iAs) in the analyzed baby food samples ranged between 4.2 and 99µgkg -1 which were below the limits of 300, 200 and 100µgkg -1 set by the Brazilian, Chinese and European legislation, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Selective extraction of traffic-related antimony compounds for speciation analysis by graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zih-Perenyi, K., E-mail: perkat@freestart.h [L. Eoetvoes University, Institute of Chemistry, H-1518 Budapest 112, P.O. Box 32. (Hungary); Neurohr, K., E-mail: kata.neurohr@gmail.co [L. Eoetvoes University, Institute of Chemistry, H-1518 Budapest 112, P.O. Box 32. (Hungary); Nagy, G. [Semmelweis University, Faculty of Pharmacy, H-1085 Budapest, Ulloi Str. 26. (Hungary); Balla, M., E-mail: balla@reakt.bme.h [Budapest University of Technology and Economics, Institute of Nuclear Techniques, H-1111 Budapest, Muegyetem rakpart 9 (Hungary); Lasztity, A., E-mail: alasztity@gmail.co [L. Eoetvoes University, Institute of Chemistry, H-1518 Budapest 112, P.O. Box 32. (Hungary)

    2010-09-15

    Most traffic-related antimony air pollutants are derived from brake dust. Brake dust contains Sb{sub 2}S{sub 3}, used as a friction material in brake pads, and its high-temperature oxidation products, Sb{sub 2}O{sub 3} or Sb{sub 2}O{sub 4}. Systematic investigations were carried out to find the most selective leaching conditions for these substances. First, solubility experiments of the pure potential compounds mentioned above were carried out. Then, the leaching of these compounds from home-made artificial dusts previously spiked with these compounds at the trace level was investigated. A 0.5 mol L{sup -1} citric acid solution proved to leach the whole Sb{sub 2}O{sub 3} content while extracting less than 10% Sb{sub 2}S{sub 3} and no Sb{sub 2}O{sub 4} at all. It was found that Sb{sub 2}O{sub 3} and Sb{sub 2}S{sub 3} traces were soluble in a 6 mol L{sup -1} HCl solution, quantitatively and selectively. Graphite furnace atomic absorption spectrometry and hydride generation graphite furnace atomic absorption spectrometry methods were developed to determine the Sb content of the extracts. The proposed method proved to be applicable to settled dust containing traffic-related Sb compounds. The detection limits were 1.2 and 0.3 {mu}g g{sup -1} for leaching by citric acid and HCl solution, respectively, which were adequate for Sb content determination in the urban dust studied. The reproducibility of the method expressed as relative standard deviation was about 7%. The results showed that the concentration of leachable Sb was 40 {mu}g g{sup -1} in the settled dust of Budapest, about half of which corresponded to Sb{sub 2}O{sub 3}. The Sb{sub 2}O{sub 4} content calculated as the difference of total and leachable fraction was about 10% with high uncertainty.

  16. The chemical generation of NO for the determination of nitrite by high-resolution continuum source molecular absorption spectrometry.

    Science.gov (United States)

    Brandao, Geovani C; Lima, Daniel C; Ferreira, Sergio L C

    2012-08-30

    In the present work, we propose a method for the determination of nitrite based on the chemical generation of nitric oxide (NO) and its detection by high-resolution continuum source molecular absorption spectrometry. NO is generated by the reduction of nitrite in acidic media with ascorbic acid as the reducing agent and then transferred into a quartz cell by a stream of argon carrier gas. The conditions under which the NO is generated are as follows: 0.4 mol L(-1) hydrochloric acid, 1.5%(w/v) ascorbic acid, an argon gas pressure of 0.03 MPa and an injection time of the reducing agent of 4s. All measurements of molecular absorption were performed using the NO line at 215.360 nm, and the signal was measured by peak height. Under these conditions, the method described has limits of detection and quantification of 0.045 and 0.150 μg mL(-1) of nitrite, respectively. The calibration curve is linear for nitrite concentrations in the range 0.15-15 μg mL(-1). The precision, estimated as the relative standard deviation (RSD), was 3.5% and 4.4% for solutions with nitrite concentrations of 0.5 and 5.0 μg mL(-1), respectively. This method was applied to the analysis of different water samples (well water, drinking water and river water) collected in Cachoeira City, Bahia State, Brazil. The results were in agreement with those obtained by a spectrophotometric method using the Griess reaction. Addition/recovery tests were also performed to check the validity of the proposed method. Recoveries of 93-106% were achieved. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Determination of lead in hair and its segmental analysis by solid sampling electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baysal, Asli, E-mail: baysalas@itu.edu.t [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak, Istanbul (Turkey); Akman, Suleyman, E-mail: akmans@itu.edu.t [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak, Istanbul (Turkey)

    2010-04-15

    A rapid and practical solid sampling electrothermal atomic absorption spectrometric method was described for the determination of lead in scalp hair. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 deg. C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The effects of pyrolysis temperature, atomization temperature, the amount of sample as well as addition of a modifier (Pd/Mg) and/or auxiliary digesting agents (hydrogen peroxide and nitric acid) and/or a surfactant (Triton X-100) on the recovery of lead were investigated. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 deg. C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The limit of detection for lead (3sigma, N = 10) was 0.3 ng/g The addition of modifier, acids, oxidant and surfactant hardly improved the results. Due to the risk of contamination and relatively high blank values, the lead in hair were determined directly without adding any reagent(s). Finally, the method was applied for the segmental determination of lead concentrations in hair of different persons which is important to know when and how much a person was exposed to the analyte. For this purpose, 0.5 cm of pieces were cut along the one or a few close strands and analyzed by solid sampling.

  18. Determination of lead in hair and its segmental analysis by solid sampling electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Baysal, Asli; Akman, Suleyman

    2010-01-01

    A rapid and practical solid sampling electrothermal atomic absorption spectrometric method was described for the determination of lead in scalp hair. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 deg. C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The effects of pyrolysis temperature, atomization temperature, the amount of sample as well as addition of a modifier (Pd/Mg) and/or auxiliary digesting agents (hydrogen peroxide and nitric acid) and/or a surfactant (Triton X-100) on the recovery of lead were investigated. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 deg. C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The limit of detection for lead (3σ, N = 10) was 0.3 ng/g The addition of modifier, acids, oxidant and surfactant hardly improved the results. Due to the risk of contamination and relatively high blank values, the lead in hair were determined directly without adding any reagent(s). Finally, the method was applied for the segmental determination of lead concentrations in hair of different persons which is important to know when and how much a person was exposed to the analyte. For this purpose, 0.5 cm of pieces were cut along the one or a few close strands and analyzed by solid sampling.

  19. Determination of Lead in Water Samples by GFAAS after Collection on Montmorillonite with Slurry Introduction.

    Science.gov (United States)

    Caliskan, Ece; Tinas, Hande; Ozbek, Nil; Akman, Suleyman

    2017-01-01

    In this study, a highly accurate, fast and practical separation/enrichment technique is described to determine the Pb in tap water samples by graphite furnace atomic absorption spectrometry. For this purpose, at first, Pb was collected on montmorillonite by batch technique, the supernatant was decanted and the solid phase was slurried in a mixture of 0.1% Triton X-114 and 0.1 mol L -1 HNO 3 then directly introduced into graphite furnace without elution. Since the elution step was not applied, the method was simpler and faster compared to conventional techniques. The risks of elution step on the precision and recovery were eliminated. Up to 50-fold enrichment could be obtained by this method. The limit of detection (3δ, N = 10) and characteristic concentration of the method for Pb were 0.46 and 1.13 μg L -1 , respectively. In addition, the Pb in water samples (tap and river) collected from different regions of Turkey were determined.

  20. Speciation of mercury in fish samples by flow injection catalytic cold vapour atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Zhang Yanlin; Adeloju, Samuel B.

    2012-01-01

    Highlights: ► Successful speciation of inorganic and organic Hg with Fe 3+ , Cu 2+ and thiourea as catalysts. ► Best sensitivity enhancement and similar sensitivity for MeHg and Hg 2+ with Fe 3+ . ► Successful use of Hg 2+ as the primary standard for quantification of inorganic and total-Hg. ► Quantitative extraction of Hg and MeHg with 2 M HCl which contained thiourea. ► Integration with FIA for rapid analysis with a sample throughput of 180 h −1 . - Abstract: A rapid flow injection catalytic cold vapour atomic absorption spectrometric (FI-CCV-AAS) method is described for speciation and determination of mercury in biological samples. Varying concentrations of NaBH 4 were employed for mercury vapour generation from inorganic and mixture of inorganic and organic (total) Hg. The presence of Fe 3+ , Cu 2+ and thiourea had catalytic effect on mercury vapour generation from methylmercury (MeHg) and, when together, Cu 2+ and thiourea had synergistic catalytic effect on the vapour generation. Of the two metal ions, Fe 3+ gave the best sensitivity enhancement, achieving the same sensitivity for MeHg and inorganic Hg 2+ . Due to similarity of resulting sensitivity, Hg 2+ was used successfully as a primary standard for quantification of inorganic and total Hg. The catalysis was homogeneous in nature, and it was assumed that the breaking of the C-Hg bond was facilitated by the delocalization of the 5d electron pairs in Hg atom. The extraction of MeHg and inorganic mercury (In-Hg) in fish samples were achieved quantitatively with hydrochloric acid in the presence of thiourea and determined by FI-CCV-AAS. The application of the method to the quantification of mercury species in a fish liver reference material DOLT-4 gave 91.5% and 102.3% recoveries for total and methyl mercury, respectively. The use of flow injection enabled rapid analysis with a sample throughput of 180 h −1 .

  1. Graphene for separation and preconcentration of trace amounts of cobalt in water samples prior to flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Yukun Wang

    2016-09-01

    Full Text Available A new sensitive and simple method was developed for the preconcentration of trace amounts of cobalt (Co using 1-(2-pyridylazo-2-naphthol (PAN as chelating reagent prior to its determination by flame atomic absorption spectrometry. The proposed method is based on the utilization of a column packed with graphene as sorbent. Several effective parameters on the extraction and complex formation were selected and optimized. Under optimum conditions, the calibration graph was linear in the concentration range of 5.0–240.0 μg L−1 with a detection limit of 0.36 μg L−1. The relative standard deviation for ten replicate measurements of 20.0 and 100.0 μg L−1 of Co were 3.45 and 3.18%, respectively. Comparative studies showed that graphene is superior to other adsorbents including C18 silica, graphitic carbon, and single- and multi-walled carbon nanotubes for the extraction of Co. The proposed method was successfully applied in the analysis of four real environmental water samples. Good spiked recoveries over the range of 95.8–102.6% were obtained.

  2. Determination of essential and toxic elements in commercial baby foods by instrumental neutron activation analysis and atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vallinoto, Priscila

    2013-01-01

    The World Health Organization recommends that infants should be breast fed exclusively for at least six months after birth. After this period, it is recommended to start introducing complementary foods, in order to meet the child's nutritional, mineral and energy needs. Commercial food products for infants form an important part of the diet for many babies. Thus, it is very important that such food contains sufficient amounts of minerals. Inadequate complementary feeding is a major cause of high rates of infant malnutrition in developing countries. In this study, essential elements: Ca, Cl, Co, Cr, Fe, K, Mg, Mn, Na, Se and Zn and toxic elements: As, Cd, Hg levels were determined in twenty seven different commercial infant food product samples by Instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometry (AAS). In order to validate both methodologies the reference material: INCT MPH-2 Mixed Polish Herbs and NIST - SRM 1577b Bovine Liver by INAA and NIST - SRM 1548th Typical Diet and NIST - SRM 1547 Peach Leaves by AAS were analyzed. The twenty seven baby food samples were acquired from Sao Paulo city supermarkets and stores. Essential and toxic elements were determined. Most of the essential element concentrations obtained were lower than the World Health Organization requirements, while concentrations of toxic elements were below the tolerable upper limit. These low essential element concentrations in these samples indicate that infants should not be fed only with commercial complementary foods. (author)

  3. Determination of inorganic arsenic and its organic metabolites in urine by flow-injection hydride generation atomic absorption spectrometry.

    Science.gov (United States)

    Hanna, C P; Tyson, J F; McIntosh, S

    1993-08-01

    A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first separated by a solid-phase extraction procedure. The remaining sample was digested with a mixture of nitric and sulfuric acids and potassium dichromate, followed by attack with hydrogen peroxide. The resulting As(V) was reduced to As(III) with potassium iodide in hydrochloric acid before injection into the flow-injection manifold. The percentage analytical recoveries (mean +/- 95% confidence interval) of various arsenic species added to a urine specimen at 250 micrograms/L were 108 +/- 2, 112 +/- 11, 104 +/- 7, and 95 +/- 5 for As(III), As(V), monomethylarsenic, and dimethylarsenic, respectively. For the determination of arsenic in Standard Reference Material 2670 (toxic metals in human urine), results agreed with the certified value (480 +/- 100 micrograms/L). Analyses of samples for the Centre de Toxicologie du Quebec, containing seafood-derived species, demonstrated the viability of the separation procedure. Detection limits were between 0.1 and 0.2 microgram/L in the solution injected into the manifold, and precision at 10 micrograms/L was between 2% and 3% (CV). These preliminary results show that the method might be applicable to determinations of arsenic in a range of clinical urine specimens.

  4. Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: Comparative study of different chemical modifiers

    Energy Technology Data Exchange (ETDEWEB)

    Vilar Farinas, M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Barciela Garcia, J. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Garcia Martin, S. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena Crecente, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Herrero Latorre, C. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)]. E-mail: cherrero@lugo.usc.es

    2007-05-22

    In this work, several analytical methods are proposed for cadmium determination in Orujo spirit samples using electrothermal atomic absorption spectrometry (ETAAS). Permanent chemical modifiers thermally coated on the platforms inserted in pyrolytic graphite tubes (such as W, Ir, Ru, W-Ir and W-Ru) were comparatively studied in relation to common chemical modifier mixtures [Pd-Mg(NO{sub 3}){sub 2} and (NH{sub 4})H{sub 2}PO{sub 4}-Mg(NO{sub 3}){sub 2}] for cadmium stabilization. Different ETAAS Cd determination methods based on the indicated modifiers have been developed. In each case, pyrolysis and atomization temperatures, atomization shapes, characteristic masses and detection limits as well as other analytical characteristics have been determined. All the assayed modifiers (permanent and conventional) were capable of achieving the appropriate stabilization of the analyte, with the exception of Ru and W-Ru. Moreover, for all developed methods, recoveries (99-102%) and precision (R.S.D. lower than 10%) were acceptable. Taking into account the analytical performance (best detection limit LOD = 0.01 {mu}g L{sup -1}), the ETAAS method based on the use of W as a permanent modifier was selected for further direct Cd determinations in Orujo samples from Galicia (NW Spain). The chosen method was applied in the determination of the Cd content in 38 representative Galician samples. The cadmium concentrations ranged

  5. Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: Comparative study of different chemical modifiers

    International Nuclear Information System (INIS)

    Vilar Farinas, M.; Barciela Garcia, J.; Garcia Martin, S.; Pena Crecente, R.; Herrero Latorre, C.

    2007-01-01

    In this work, several analytical methods are proposed for cadmium determination in Orujo spirit samples using electrothermal atomic absorption spectrometry (ETAAS). Permanent chemical modifiers thermally coated on the platforms inserted in pyrolytic graphite tubes (such as W, Ir, Ru, W-Ir and W-Ru) were comparatively studied in relation to common chemical modifier mixtures [Pd-Mg(NO 3 ) 2 and (NH 4 )H 2 PO 4 -Mg(NO 3 ) 2 ] for cadmium stabilization. Different ETAAS Cd determination methods based on the indicated modifiers have been developed. In each case, pyrolysis and atomization temperatures, atomization shapes, characteristic masses and detection limits as well as other analytical characteristics have been determined. All the assayed modifiers (permanent and conventional) were capable of achieving the appropriate stabilization of the analyte, with the exception of Ru and W-Ru. Moreover, for all developed methods, recoveries (99-102%) and precision (R.S.D. lower than 10%) were acceptable. Taking into account the analytical performance (best detection limit LOD = 0.01 μg L -1 ), the ETAAS method based on the use of W as a permanent modifier was selected for further direct Cd determinations in Orujo samples from Galicia (NW Spain). The chosen method was applied in the determination of the Cd content in 38 representative Galician samples. The cadmium concentrations ranged -1

  6. Determination of methylmercury by electrothermal atomic absorption spectrometry using headspace single-drop microextraction with in situ hydride generation

    International Nuclear Information System (INIS)

    Gil, Sandra; Fragueiro, Sandra; Lavilla, Isela; Bendicho, Carlos

    2005-01-01

    A new method is proposed for preconcentration and matrix separation of methylmercury prior to its determination by electrothermal atomic absorption spectrometry (ETAAS). Generation of methylmercury hydride (MeHgH) from a 5-ml solution is carried out in a closed vial and trapped onto an aqueous single drop (3-μl volume) containing Pd(II) or Pt(IV) (50 and 10 mg/l, respectively). The hydrogen evolved in the headspace (HS) after decomposition of sodium tetrahydroborate (III) injected for hydride generation caused the formation of finely dispersed Pd(0) or Pt(0) in the drop, which in turn, were responsible for the sequestration of MeHgH. A preconcentration factor of ca. 40 is achieved with both noble metals used as trapping agents. The limit of detection of methylmercury was 5 and 4 ng/ml (as Hg) with Pd(II) or Pt(IV) as trapping agents, and the precision expressed as relative standard deviation was about 7%. The preconcentration system was fully characterised through optimisation of the following variables: Pd(II) or Pt(IV) concentration in the drop, extraction time, pH of the medium, temperatures of both sample solution and drop, concentration of salt in the sample solution, sodium tetrahydroborate (III) concentration in the drop and stirring rate. The method has been successfully validated against two fish certified reference materials (CRM 464 tuna fish and CRM DORM-2 dogfish muscle) following selective extraction of methylmercury in 2 mol/l HCl medium

  7. Nickel and strontium nitrates as modifiers for the determination of selenium in wine by Zeeman electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cvetkovic, J. [Inst. of Agriculture, Skopje (Yugoslavia); Stafilov, T. [Inst. of Chemistry, Faculty of Science Sts. Cyril and Methodius Univ., Skopje (Yugoslavia); Mihajlovic, D. [RZ Tehnicka Kontrola, Skopje (Yugoslavia)

    2001-08-01

    A mixed matrix modifier of nickel and strontium nitrates was used as a chemical modifier for the determination of selenium in wines by Zeeman electrothermal atomic absorption spectrometry. Wine samples were heated on a boiling water bath with small amounts of nitric acid and hydrogen peroxide. For complete elimination of interference, especially from sulfates and phosphates, selenium is complexed with ammonium pyrolidinedithiocarbamate (APDTC), extracted into methyl isobutyl ketone (MIBK), and measured by ETAAS. The graphite furnace temperature program was optimized for both aqueous and organic solutions. Pyrolysis temperatures of 1300 C and 800 C were chosen for aqueous and organic solutions, respectively; 2700 C and 2100 C were used as optimum atomization temperatures for aqueous and organic solutions, respectively. The optimum modifier mass established is markedly lower than those presented in the literature. The platform atomization ensures pretreatment stabilization up to 1100 C and 1600 C, respectively, for organic and aqueous selenium solutions. The procedure was verified by the method of standard addition. The investigated wine samples originated from the different regions of the Republic of Macedonia. The selenium concentration varied from not detectable to 0.93 {mu}g L{sup -1}. (orig.)

  8. On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ferrua, N.; Cerutti, S.; Salonia, J.A.; Olsina, R.A.; Martinez, L.D.

    2007-01-01

    An on-line procedure for the determination of traces of total mercury in environmental and biological samples is described. The present methodology combines cold vapor generation associated to atomic absorption spectrometry (CV-AAS) with preconcentration of the analyte on a minicolumn packed with activated carbon. The retained analyte was quantitatively eluted from the minicolumn with nitric acid. After that, volatile specie of mercury was generated by merging the acidified sample and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the atomizer device. Optimizations of both, preconcentration and mercury volatile specie generation variables were carried out using two level full factorial design (2 3 ) with 3 replicates of the central point. Considering a sample consumption of 25 mL, an enrichment factor of 13-fold was obtained. The detection limit (3σ) was 10 ng L -1 and the precision (relative standard deviation) was 3.1% (n = 10) at the 5 μg L -1 level. The calibration curve using the preconcentration system for mercury was linear with a correlation coefficient of 0.9995 at levels near the detection limit up to at least 1000 μg L -1 . Satisfactory results were obtained for the analysis of mercury in tap water and hair samples

  9. Investigation of interference mechanism of cobalt chloride on the determination of bismuth by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tokman, Nilgun [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, Maslak, Istanbul 34469 (Turkey); Akman, Suleyman [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, Maslak, Istanbul 34469 (Turkey)]. E-mail: akmans@itu.edu.tr

    2005-03-31

    The interferences of cobalt chloride on the determination of bismuth by electrothermal atomic absorption spectrometry (ETAAS) were examined using a dual cavity platform (DCP), which allows the gas-phase and condensed phase interferences to be distinguished. Effects of pyrolysis temperature, pyrolysis time, atomization temperature, heating rate in the atomization step, gas-flow rate in the pyrolysis and atomization steps, interferent mass and atomization from wall on sensitivity as well as atomization signals were studied to explain the interference mechanisms. The mechanism proposed for each experiment was verified with other subsequent sets of experiments. Finally, modifiers pipetted on the thermally treated sample+interferent mixture and pyrolyzed at different temperatures provided very useful information for the existence of volatilization losses of analyte before the atomization step. All experiments confirmed that when low pyrolysis temperatures are applied, the main interference mechanisms are the gas-phase reaction between bismuth and decomposition products of cobalt chloride in the atomization step. On the other hand, at elevated temperatures, the removal of a volatile compound formed between analyte and matrix constituents is responsible for some temperature-dependent interferences, although gas-phase interferences still continue. The experiments performed with colloidal palladium and nickel nitrate showed that the modifier behaves as both a matrix modifier and analyte modifier, possibly delaying the vaporization of either analyte or modifier or both of them.

  10. Sensitive determination of cadmium in water samples by room temperature ionic liquid-based preconcentration and electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Martinis, Estefania M. [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, C.C. 131, M 5502 IRA Mendoza (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Olsina, Roberto A. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis (Argentina); Altamirano, Jorgelina C. [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, C.C. 131, M 5502 IRA Mendoza (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina); Wuilloud, Rodolfo G. [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, C.C. 131, M 5502 IRA Mendoza (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)], E-mail: rwuilloud@mendoza-conicet.gov.ar

    2008-10-17

    A sensitive preconcentration methodology for Cd determination at trace levels in water samples was developed in this work. 1-Butyl-3-methylimidazolium hexafluorophosphate ([C{sub 4}MIM][PF{sub 6}]) room temperature ionic liquid (RTIL) was successfully used for Cd preconcentration, as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex [Cd-5-Br-PADAP]. Subsequently, Cd was back-extracted from the RTIL phase with 500 {mu}L of 0.5 mol L{sup -1} nitric acid and determined by electrothermal atomic absorption spectrometry (ETAAS). A preconcentration factor of 40 was achieved with 20 mL of sample. The limit of detection (LOD) obtained under optimum conditions was 3 ng L{sup -1} and the relative standard deviation (R.S.D.) for 10 replicates at 1 {mu}g L{sup -1} Cd{sup 2+} concentration level was 3.5%, calculated at peak heights. The calibration graph was linear from concentration levels near the detection limits up to at least 5 {mu}g L{sup -1}. A correlation coefficient of 0.9997 was achieved. Validation of the methodology was performed by standard addition method and analysis of certified reference material (CRM). The method was successfully applied to the determination of Cd in river and tap water samples.

  11. Analysis of trace element in intervertebral disc by Atomic Absorption Spectrometry techniques in degenerative disc disease in the Polish population

    Directory of Open Access Journals (Sweden)

    Andrzej Nowakowski

    2015-05-01

    Full Text Available Objective. Although trace elements are regarded crucial and their content has been determined in number of tissue there are only few papers addressing this problem in intervertebral disc in humans. Most of the trace elements are important substrates of enzymes influencing metabolism and senescence process. Others are markers of environmental pollution. Therefore the aim of the research was to analyzed of the trace element content in the intervertebral disc, which may be a vital argument recognizing the background of degenerative changes to be the effect of the environment or metabolic factors. Materials and methods. Material consist of 18 intervertebral disc from 15 patients, acquired in surgical procedure of due to the degenerative disease with Atomic Absorption Spectrometry content of Al, Cd, Co, Pb, Cu, Ni, Mo, Mg, Zn was evaluated. Results. Only 4 of the trace elements were detected in all samples. The correlation analysis showed significant positive age correlation with Al and negative in case of Co. Among elements significant positive correlation was observed between Al/Pb, Co/Mo, Al/Mg, Al/Zn Pb/Zn and Mg/Zn. Negative correlation was observed in Al/Co, Cd/Mg, Co/Mg, Mo/Mg, Co/Zn and Mo/Zn. Conclusions. This study is the first to our knowledge that profiles the elements in intervertebral disc in patients with degenerative changes. We have confirmed significant differences between the trace element contents in intervertebral disc and other tissue. It can be ground for further investigation.

  12. Coprecipitation with metal hydroxides for the determination of beryllium in seawater by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Hiraide, M.; Ishikawa, K.; Chen, Z.S.; Kawaguchi, H.

    1994-01-01

    Coprecipitation first with magnesium hydroxide. next with tin(IV) hydroxide is developed for the determination of traces of beryllium in seawater. To a 200-ml sample is added a sodium hydroxide solution to form magnesium hydroxide at pH 11.5, on which beryllium is quantitatively coprecipitated. The precipitate is separated by centrifugation and dissolved in 2 ml of 12 mol/l hydrochloric acid. The resulting solution (ca. 10 ml) is mixed with 2 mg of tin(IV) carrier and the pH is adjusted to 5.0 to collect the beryllium on tin(IV) hydroxide, leaving magnesium ions in the solution. The tin(IV) hydroxide is centrifuged, dissolved in 0.1 ml of 5 mol/l hydrobromic acid, and then diluted to 1 ml with water. Magnesium is so added as to be 500 μg/ml for increasing the sensitivity about four times, and the beryllium in the solution is determined by graphite furnace atomic absorption spectrometry. The experiments with synthetic seawater samples showed that pg-μg amounts of beryllium can be coprecipitated on the metal hydroxides and beryllium at the low ng/l level can be determined with reasonable precision (RSD < 10%). The detection limit of the proposed method is 0.5 ng/l of beryllium in seawater. (author)

  13. The use of slurry sampling for the determination of manganese and copper in various samples by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Tokman, Nilgun

    2007-01-01

    Manganese and copper in multivitamin-mineral supplements and standard reference materials were determined by slurry sampling electrothermal atomic absorption spectrometry. Slurries were prepared in an aqueous solution containing Triton X-100. The effects of different parameters such as ratio of solid to liquid phase volume, total slurry volume and addition of Triton X-100 as a dispersant on the analytical results were investigated. The graphite furnace programs were optimized for slurry sampling depending on the analytes and their concentrations in the samples. The linear calibration method with aqueous standard solutions was used for the quantification. At optimum experimental conditions, R.S.D. values were below 5%. The analytes were determined in the limits of 95% confidence level with respect to certified values in coal and soil standard reference materials and to those found by wet-digestion in multivitamin-mineral supplements. Detection limits (3δ) for Mn and Cu were 0.10 μg L -1 and 1.82 μg L -1 for 10 μL coal standard reference material slurry, respectively

  14. Determination of trace copper in food samples by flame atomic absorption spectrometry after solid phase extraction on modified soybean hull

    International Nuclear Information System (INIS)

    Xiang Guoqiang; Zhang Yingming; Jiang Xiuming; He Lijun; Fan Lu; Zhao Wenjie

    2010-01-01

    Soybean hull was chemically modified with citric acid and used as a solid phase extraction adsorbent for the determination of trace amounts of Cu 2+ in food samples by flame absorption spectrometry (FAAS). The effect of pH, sample flow rate and volume, elution flow rate and volume and co-existing ions on the recovery of the analyte were investigated. The results showed that Cu 2+ could be adsorbed on the modified soybean hull at pH 8.0 and eluted by 2.0 mL of 1.0 mol L -1 HCl. Under the optimized conditions, the adsorption capacity of modified soybean hull was found to be 18.0 mg g -1 for Cu 2+ . The detection limit of the proposed method was 0.8 ng mL -1 for Cu 2+ with an enrichment factor of 18. The analytical result for the certified reference tea sample (GBW07605) was in a good agreement with the certified value. The proposed method has also been successfully applied to the determination of trace Cu 2+ in dried sweet potato, lake water and milk powder, the recovery of Cu 2+ for spiked samples was between 91% and 109.6%.

  15. Determination of lead in flour samples directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Tinas, Hande; Ozbek, Nil; Akman, Suleyman

    2018-02-01

    In this study, lead concentrations in various flour samples were determined by high-resolution continuum source graphite furnace atomic absorption spectrometry with solid sampling. Since samples were analyzed directly, the risks and disadvantages of sample digestion were eliminated. Solid flour samples were dried, weighed on the platforms, Pd was added as a modifier and introduced directly into a graphite tube using a manual solid sampler. Platforms and tubes were coated with Zr. The optimized pyrolysis and atomization temperatures were 800 °C and 2200 °C, respectively. The sensitivities of lead in various flour certified reference materials (CRMs) and aqueous standards were not significantly different. Therefore, aqueous standards were safely used for calibration. The absolute limit of detection and characteristic mass were 7.2 pg and 9.0 pg of lead, respectively. The lead concentrations in different types of flour samples were found in the range of 25-52 μg kg- 1. Finally, homogeneity factors representing the heterogeneity of analyte distribution for lead in flour samples were determined.

  16. Determination of arsenic in petroleum refinery streams by electrothermal atomic absorption spectrometry after multivariate optimization based on Doehlert design

    Science.gov (United States)

    Cassella, Ricardo J.; de Sant'Ana, Otoniel D.; Santelli, Ricardo E.

    2002-12-01

    This paper reports the development of a methodology for the determination of arsenic in petroleum refinery aqueous streams containing large amounts of unknown volatile organic compounds, employing electrothermal atomic absorption spectrometry with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of chemical modification and the drying step was examined. Also, pyrolysis and atomization temperatures and the amount of nitric acid added to the sample were optimized using a multivariate approach based on Doehlert matrix. Obtained results indicate that, in this kind of sample, arsenic must be determined by standard addition procedure with a careful control of the drying step temperature and ramp pattern. In order to evaluate the accuracy of the procedure, a test was performed in six spiked samples of petroleum refinery aqueous streams and the relative errors verified in the analysis of such samples (added As between 12.5 and 190 μg l -1) ranged from -7.2 to +16.7%. The detection limit and the relative standard deviation were also calculated and the values are 68 pg and 7.5% (at 12.5 μg l -1 level), respectively.

  17. Determination of arsenic in petroleum refinery streams by electrothermal atomic absorption spectrometry after multivariate optimization based on Doehlert design

    International Nuclear Information System (INIS)

    Cassella, Ricardo J.; Sant'Ana, Otoniel D. de; Santelli, Ricardo E.

    2002-01-01

    This paper reports the development of a methodology for the determination of arsenic in petroleum refinery aqueous streams containing large amounts of unknown volatile organic compounds, employing electrothermal atomic absorption spectrometry with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of chemical modification and the drying step was examined. Also, pyrolysis and atomization temperatures and the amount of nitric acid added to the sample were optimized using a multivariate approach based on Doehlert matrix. Obtained results indicate that, in this kind of sample, arsenic must be determined by standard addition procedure with a careful control of the drying step temperature and ramp pattern. In order to evaluate the accuracy of the procedure, a test was performed in six spiked samples of petroleum refinery aqueous streams and the relative errors verified in the analysis of such samples (added As between 12.5 and 190 μg l -1 ) ranged from -7.2 to +16.7%. The detection limit and the relative standard deviation were also calculated and the values are 68 pg and 7.5% (at 12.5 μg l -1 level), respectively

  18. Determination of Gold in Various Environment Samples by Flame Atomic Absorption Spectrometry Using Dispersive Liquid–Liquid Microextraction Sampling

    Directory of Open Access Journals (Sweden)

    Şerife Saçmacı

    2015-07-01

    Full Text Available A new dispersive liquid–liquid microextraction separation/preconcentration procedure as a rapid sample-preparation technique is proposed for detection of ultra trace amounts of Au(III in various media by flame atomic absorption spectrometry using 1,5-diphenyl-1,3,5-pentanetrione as chelating agent. Carbon tetrachloride and methanol were used as extraction and dispersive solvents, respectively. Various parameters that affect the extraction efficiency such as pH, centrifugation rate and time, chelating agent concentration and sampling volume on the recovery of Au(III were investigated. Under optimum conditions, the enhancement factor of 750, relative standard deviation of 2.7 % and calibration graphs obtained in the concentration range of 0.04–5.6 μg L−1 for gold were obtained. The limit of detection was 1.1 ng L−1. The accuracy of the method was performed by analysis of the certified reference material (CDN-PGMS-10. The developed method was applied successfully to the determination of gold in the catalytic converter, anode slime, ore and seawater samples. The results show that dispersive liquid–liquid microextraction procedure is sensitive, rapid, simple and safe for the separation/preconcentration of gold from complex sample media.

  19. Determining the arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillets from Vietnam.

    Science.gov (United States)

    Molognoni, Luciano; Vitali, Luciano; Ploêncio, Leandro As; Santos, Jacson N; Daguer, Heitor

    2016-07-01

    Pangasius is a fish produced on a large scale in Vietnam and exported to many countries. Since river contamination from human activities can affect the safety of this food, fish consumption can cause exposure to potentially toxic elements for humans. The aim of this study, therefore, was to assess arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillet produced in the provinces of Dong Thap and Can Tho (Vietnam) and exported to Brazil. The limits of detection were: arsenic 0.5443 µg kg(-1) , cadmium 0.0040 mg kg(-1) , chromium 0.0004 mg kg(-1) , copper 0.0037 mg kg(-1) and lead 0.0284 mg kg(-1) . Analysis of 20 samples showed results below the limit of detection for arsenic, chromium and lead, while copper average concentration was 0.0234 mg kg(-1) . Cadmium average concentration was 0.0547 mg kg(-1) , with no significant difference between the two regions studied. The samples of Pangasius had no detectable concentrations of arsenic, chromium, copper and lead, and do not represent a hazard to public health. However, cadmium analysis revealed non-compliant samples, demonstrating the importance of monitoring the quality of imported Pangasius fish. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  20. In-situ suspended aggregate microextraction of gold nanoparticles from water samples and determination by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Choleva, Tatiana G; Kappi, Foteini A; Tsogas, George Z; Vlessidis, Athanasios G; Giokas, Dimosthenis L

    2016-05-01

    This work describes a new method for the extraction and determination of gold nanoparticles in environmental samples by means of in-situ suspended aggregate microextraction and electrothermal atomic absorption spectrometry. The method relies on the in-situ formation of a supramolecular aggregate phase through ion-association between a cationic surfactant and a benzene sulfonic acid derivative. Gold nanoparticles are physically entrapped into the aggregate phase which is separated from the bulk aqueous solution by vacuum filtration on the surface of a cellulose filter in the form of a thin film. The film is removed from the filter surface and is dissociated into an acidified methanolic solution which is used for analysis. Under the optimized experimental conditions, gold nanoparticles can be efficiently extracted from water samples with recovery rates between 81.0-93.3%, precision 5.4-12.0% and detection limits as low as 75femtomolL(-1) using only 20mL of sample volume. The satisfactory analytical features of the method along with the simplicity indicate the efficiency of this new approach to adequately collect and extract gold nanoparticle species from water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Simultaneous preconcentration of cadmium and lead in water samples with silica gel and determination by flame atomic absorption spectrometry.

    Science.gov (United States)

    Xu, Hongbo; Wu, Yun; Wang, Jian; Shang, Xuewei; Jiang, Xiaojun

    2013-12-01

    A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  2. Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation

    International Nuclear Information System (INIS)

    Aleixo, Poliana Carolina; Junior, Dario Santos; Tomazelli, Andrea Cristina; Rufini, Iolanda A.; Berndt, Harald; Krug, Francisco Jose

    2004-01-01

    A simple method for cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry (BIFF-AAS) was proposed. Food slurries were prepared by transferring an exact amount of cryogenic-ground homogenized material (50-100 mg) to centrifuge tubes, followed by addition of 5 ml (up to 2.8 mol l -1 ) nitric acid solution and sonication in an ultrasonic bath during 5-10 min. Thereafter, slurries were diluted with water to 10 ml, centrifuged during 5 min at 5400 rpm and 400 μl aliquot of the supernatant was analyzed by BIFF-AAS. The detection limits based on peak height measurements were 0.03 μg g -1 Cd and 1.6 μg g -1 Pb for 2% (m/v) slurry (200 mg/10 ml). For method validation, the certified reference materials Pig Kidney (BCR 186) and Rice Flour (NIES 10) were used. Quantitative cadmium and lead recoveries were obtained and no statistical differences were found at 95% level by applying the t-test

  3. Discussion of parameters associated with the determination of arsenic by electrothermal atomic absorption spectrometry in slurried environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Vassileva, E.; Baeten, H.; Hoenig, M. [Centre for Veterinary and Agrochemical Research (CERVA), Tervuren (Belgium)

    2001-01-01

    A slurry sampling - fast program procedure has been developed for the determination of arsenic in plants, soils and sediments by electrothermal atomic absorption spectrometry. Efficiencies of various single and mixed modifiers for thermal stabilization of arsenic and for a better removal of the matrix during pyrolysis step were compared. The influence of the slurry concentration, amounts of modifier and parameters of the pyrolysis step on the As integrated absorbance signals have been studied and a comparison between fast and conventional furnace programs was also made. The ultrasonic agitation of the slurry followed by a fast electrothermal program using an Ir/Mg modifier provides the most consistent performance in terms of precision and accuracy. The reliability of the whole procedure has been compared with results obtained after application of a wet digestion method with an HF step and validated by analyzing eleven certified reference materials. Arsenic detection and quantitation limits expressed on dry sample matter were about 30 and 100 {mu}g kg{sup -1}, respectively. (orig.)

  4. Determination of trace copper in food samples by flame atomic absorption spectrometry after solid phase extraction on modified soybean hull

    Energy Technology Data Exchange (ETDEWEB)

    Xiang Guoqiang, E-mail: xianggq@126.com [School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001 (China); Zhang Yingming; Jiang Xiuming; He Lijun; Fan Lu; Zhao Wenjie [School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001 (China)

    2010-07-15

    Soybean hull was chemically modified with citric acid and used as a solid phase extraction adsorbent for the determination of trace amounts of Cu{sup 2+} in food samples by flame absorption spectrometry (FAAS). The effect of pH, sample flow rate and volume, elution flow rate and volume and co-existing ions on the recovery of the analyte were investigated. The results showed that Cu{sup 2+} could be adsorbed on the modified soybean hull at pH 8.0 and eluted by 2.0 mL of 1.0 mol L{sup -1} HCl. Under the optimized conditions, the adsorption capacity of modified soybean hull was found to be 18.0 mg g{sup -1} for Cu{sup 2+}. The detection limit of the proposed method was 0.8 ng mL{sup -1} for Cu{sup 2+} with an enrichment factor of 18. The analytical result for the certified reference tea sample (GBW07605) was in a good agreement with the certified value. The proposed method has also been successfully applied to the determination of trace Cu{sup 2+} in dried sweet potato, lake water and milk powder, the recovery of Cu{sup 2+} for spiked samples was between 91% and 109.6%.

  5. Multi-elemental analysis of Ziziphora clinopodioidesfrom different regions, periods and parts using atomic absorption spectrometry and chemometric approaches

    Directory of Open Access Journals (Sweden)

    Xuejia Zhang

    Full Text Available ABSTRACTIn this study, ten trace elements in Ziziphora clinopodioidesLam., Lamiaceae, from different regions, periods and parts in Xinjiang were determined by atomic absorption spectrometry following microwave-assisted acid digestion. The decreasing sequence of elements levels was K > Ca > Mg > Fe > Cu > Zn > Na > Mn > Cd > Pb. Chemometric approaches, such as correlation analysis, principal component analysis, and hierarchical cluster analysis were applied to classify Z. clinopodioides according to its elements contents. Principal component analysis revealed 83.51% of the variance with the first four principal component variables. Hierarchical cluster analysis indicated five groups from the eighteen regions, and the result of classification can correspond to the geographical distribution for the most regions. Variation in the elements exhibited a decreasing trend, but of different types in the studied periods. Elemental contents distributed in leaves were higher than those in flowers and stems. Therefore, chemometric approaches could be used to analyze data to accurately classify Z. clinopodioides according to origins. This study provided some elemental information on chemotaxonomy, diversity, changing pattern, distribution, and metabolism of Z. clinopodioides at spatial and temporal levels, and could be used as a reference of planting and quality standards.

  6. Application of atomic absorption spectrometry with continuous light source to analyze selected metals important for human health in different parts of oranges

    Directory of Open Access Journals (Sweden)

    Szwerc Wojciech

    2014-09-01

    Full Text Available The publication describes the application of high-resolution continuum source atomic absorption spectrometry (H-R CS AAS to determine some physiologically essential and toxic elements occurring in citrus fruits of different origins. Before analysis, the samples were mineralized using a mixture of deionized water and 69% nitric acid 3:1 (v/v in high pressure microwave digestion at 188°C during one hour.

  7. Trace mercury determination in drinking and natural water after preconcentration and separation by DLLME-SFO method coupled with cold vapor atomic absorption spectrometry

    OpenAIRE

    Abdollahi Atousa; Amirkavehei Mooud; Gheisari Mohammad Mehdi; Tadayon Fariba

    2014-01-01

    A novel dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for simultaneous separation/preconcentration of ultra trace amounts of mercury was used. A method based on amalgamation was used for collection of gaseous mercury on gold coated sand (Gold trap). The concentration of mercury was determined by cold vapor atomic absorption spectrometry (CV-AAS). The DLLME-SFO behavior of mercury by using dithizone as complexing agent was systematically ...

  8. Determination of arsenic and cadmium in shellfish samples by graphite furnace atomic absorption spectrometry using matrix modifier

    International Nuclear Information System (INIS)

    Cortez Diaz, Mirella del Carmen

    2002-01-01

    Heavy metals are a big source of environmental contamination and are also highly toxic to humans. Since shellfish are bio-accumulators of these metals, proper techniques for quantifying them should be available. This work aims to develop an analytical method for the quantitative determination of heavy metals in biological materials (shellfish), specifically arsenic and cadmium at the trace level, using graphite furnace atomic absorption spectrometry, for which nickel and phosphate solutions were used to modify the modifiers. Prior to the analysis, the sample was diluted with nitric acid in a DAB II pressure digestion system order to destroy the organic matter. The instrument conditions were initially set (wavelength, slit, integration peaks, graphite tube, etc.), then the work range was defined for each element and the most appropriate operational parameters were studied, such as: temperature, ramp times, hold times and internal gas flow, in the different stage of the electrothermal treatment (drying, calcination, atomization) for the furnace program. Once the above mentioned conditions were set and since this was a biological sample, a matrix chemical modifier had to be used, in order to make the elements that accompany the element being studied more volatile. In this way the chemical and spectral interferences decrease together with the high background absorption of the matrix. Therefore, different matrix modifiers were studied for the definition of each analyte. The method validation was done using Certified Oyster Tissue Reference Material N o 1566a from the National Institute of Standards and Technology applying different tests in order to eliminate outliers. Repeatability, uncertainty, sensitivity, lineal range, working range, detection limit and quantification limit were evaluated for each element, and the results were compared with the values for the certified material. The Fisher and Student tests were the statistical tools used. The experimental values

  9. Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues

    International Nuclear Information System (INIS)

    Resano, M.; Briceno, J.; Aramendia, M.; Belarra, M.A.

    2007-01-01

    In this work, the potential of graphite furnace atomic absorption spectrometry for the direct determination of B in plant tissues has been investigated. Three certified reference materials (NIST SRM 1570a spinach leaves, NIST SRM 1573a tomato leaves and BCR CRM 679 white cabbage) were selected for this study, the goal always being to develop a fast procedure that could be robust enough to provide a satisfactory performance for all of them, without any modifications in the conditions applied. The use of a suitable chemical modifier was found to be essential for obtaining a reproducible and sufficiently sensitive signal for boron solutions. In this regard, the performance of the combination of citric acid plus W (added as a permanent modifier) was noteworthy, resulting in well-defined signal profiles, a remarkable analyte stabilization during the pyrolysis step (up to 2100 deg. C) and minimal memory effects. This mixture of modifiers provided a good performance for the direct analysis of solid samples as well, but only if a suitable temperature program, favoring the interaction between the analyte and the modifiers, was used. Thus, such a temperature program, with two pyrolysis steps and the addition of NH 4 NO 3 in order to carry out the in situ sample microdigestion, was optimized. Under these conditions, the peak areas obtained for both solid samples and aqueous standards were comparable. Finally, the analysis of the samples was carried out. In all cases, a good agreement with the certified values was obtained, while R.S.D. values ranged between 6 and 10%. It can be concluded that the method proposed shows significant advantages for the determination of this complicated element in solid samples such as the use of aqueous standards for calibration, a high sample throughput (20 min per sample), a suitable limit of detection (0.3 μg g -1 ) and reduced risk of analyte losses and contamination

  10. Determination of ultra trace arsenic species in water samples by hydride generation atomic absorption spectrometry after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ulusoy, Halil Ibrahim, E-mail: hiulusoy@yahoo.com [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey); Akcay, Mehmet; Ulusoy, Songuel; Guerkan, Ramazan [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey)

    2011-10-10

    Graphical abstract: The possible complex formation mechanism for ultra-trace As determination. Highlights: {yields} CPE/HGAAS system for arsenic determination and speciation in real samples has been applied first time until now. {yields} The proposed method has the lowest detection limit when compared with those of similar CPE studies present in literature. {yields} The linear range of the method is highly wide and suitable for its application to real samples. - Abstract: Cloud point extraction (CPE) methodology has successfully been employed for the preconcentration of ultra-trace arsenic species in aqueous samples prior to hydride generation atomic absorption spectrometry (HGAAS). As(III) has formed an ion-pairing complex with Pyronine B in presence of sodium dodecyl sulfate (SDS) at pH 10.0 and extracted into the non-ionic surfactant, polyethylene glycol tert-octylphenyl ether (Triton X-114). After phase separation, the surfactant-rich phase was diluted with 2 mL of 1 M HCl and 0.5 mL of 3.0% (w/v) Antifoam A. Under the optimized conditions, a preconcentration factor of 60 and a detection limit of 0.008 {mu}g L{sup -1} with a correlation coefficient of 0.9918 was obtained with a calibration curve in the range of 0.03-4.00 {mu}g L{sup -1}. The proposed preconcentration procedure was successfully applied to the determination of As(III) ions in certified standard water samples (TMDA-53.3 and NIST 1643e, a low level fortified standard for trace elements) and some real samples including natural drinking water and tap water samples.

  11. Coacervative extraction of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagarová, Ingrid, E-mail: hagarova@fns.uniba.sk; Bujdoš, Marek; Matúš, Peter; Kubová, Jana

    2013-10-01

    In this work, a relatively simple and sensitive method for separation/preconcentration of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry has been proposed. The method is based on the extraction of Pb–dithizone chelate with coacervates made up of lauric acid in the presence of potassium ions and methanol. Several important factors affecting extraction efficiency such as pH, concentration of lauric acid and dithizone, ionic strength, incubation and centrifugation time were investigated and optimized. After separation of aqueous bulk solution from surfactant-rich phase, the final extract was redissolved by using 500 μl of methanol acidified with 0.2 mol l{sup −1} HNO{sub 3}. Under the optimized conditions (using initial sample volume of 10 ml), enrichment factor of 17.0, detection limit of 0.12 μg l{sup −1}, quantification limit of 0.38 μg l{sup −1}, relative standard deviation of 4.2% (for 2 μg l{sup −1} of Pb; n = 26), linearity of the calibration graph in the range of 0.5–4.0 μg l{sup −1} (with correlation coefficient better than 0.995) were achieved. The method was validated by the analysis of certified reference material (TMDA-61). Extraction recoveries for the CRM, spiked model solutions and spiked natural water samples were in the range of 91–96%. Finally, the method was applied to the separation/preconcentration and determination of trace lead in natural waters. - Highlights: • The potential of coacervates for the extraction of metal ions is examined. • No difficulties in coupling of ETAAS with the proposed CAE are observed. • Achieved preconcentration factor results in enhanced sensitivity. • Analytical performance is confirmed by the reliable determination of trace Pb. • The proposed CAE is ecofriendly and efficient.

  12. Determination of inorganic and total mercury by vapor generation atomic absorption spectrometry using different temperatures of the measurement cell

    Energy Technology Data Exchange (ETDEWEB)

    Kaercher, Luiz Eduardo [Universidade Federal de Santa Maria, Departamento de Quimica, Campus de Camobi, 97105900 Santa Maria, RS (Brazil); Goldschmidt, Fabiane [Universidade Federal de Santa Maria, Departamento de Quimica, Campus de Camobi, 97105900 Santa Maria, RS (Brazil); Paniz, Jose Neri Gottfried [Universidade Federal de Santa Maria, Departamento de Quimica, Campus de Camobi, 97105900 Santa Maria, RS (Brazil); Moraes Flores, Erico Marlon de [Universidade Federal de Santa Maria, Departamento de Quimica, Campus de Camobi, 97105900 Santa Maria, RS (Brazil); Dressler, Valderi Luiz [Universidade Federal de Santa Maria, Departamento de Quimica, Campus de Camobi, 97105900 Santa Maria, RS (Brazil)]. E-mail: valdres@quimica.ufsm.br

    2005-06-30

    A simple and inexpensive laboratory-built flow injection vapor generation system coupled to atomic absorption spectrometry (FI-VG AAS) for inorganic and total mercury determination has been developed. It is based on the vapor generation of total mercury and a selective detection of Hg{sup 2+} or total mercury by varying the temperature of the measurement cell. Only the inorganic mercury is measured when the quartz cell is at room temperature, and when the cell is heated to 650 deg. C or higher the total Hg concentration is measured. The organic Hg concentration in the sample is calculated from the difference between the total Hg and Hg{sup 2+} concentrations. Parameters such as the type of acid (HCl or HNO{sub 3}) and its concentration, reductant (NaBH{sub 4}) concentration, carrier solution (HCl) flow rate, carrier gas flow rate, sample volume and quartz cell temperature, which influence FI-VG AAS system performance, were systematically investigated. The optimized conditions for Hg{sup 2+} and total Hg determinations were: 1.0 mol l{sup -1} HCl as carrier solution, carrier flow rate of 3.5 ml min{sup -1}, 0.1% (m/v) NaBH{sub 4}, reductant flow rate of 1.0 ml min{sup -1} and carrier gas flow rate of 200 ml min{sup -1}. The relative standard deviation (RSD) is lower than 5.0% for a 1.0 {mu}g l{sup -1} Hg solution and the limit of quantification (LOQ, 10 s) is 55 ng g{sup -1}. Certified samples of dogfish muscle (DORM-1 and DORM-2) and non-certified fish samples were analyzed, using a 6.0 mol l{sup -1} HCl solution for analyte extraction. The Hg{sup 2+} and CH{sub 3}Hg{sup +} concentrations found were in agreement with certified ones.

  13. Hair in Parkinson's disease patients exhibits differences in Calcium, Iron and Zinc concentrations measured by flame atomic absorption spectrometry - FAAS.

    Science.gov (United States)

    Dos Santos, Altair B; Kohlmeier, Kristi A; Rocha, Marcelo E; Barreto, George E; Barreto, Jeferson A; de Souza, Ana Carla A; Bezerra, Marcos A

    2018-05-01

    Imbalances in metals have emerged as playing a role in the pathophysiology of Parkinson's Disease (PD). Monitoring of metal levels could serve as a biomarker of presence, or future development, of this disease. To this end, we evaluated the ability of flame atomic absorption spectrometry (FAAS) to assess the concentrations of Ca, Fe and Zn in hair of PD patients and to investigate if there was an association with age and disease duration. Hair samples were collected from 26 clinically-diagnosed PD patients, and 33 healthy individuals. Concentrations of Ca and Fe were lower in PD patients when compared to control, whereas, a higher concentration of Zn was detected in PD patients. Levels of Ca and Fe did not vary with age nor with the duration of PD. While Zn did not present variation with duration of the disease, there was a correlation with age as PD patients older than 65 years exhibited a higher concentration of Zn than controls. We conclude that FAAS is useful for detecting differences in Fe, Ca and Zn in hair samples of patients with PD. Hair samples required for this method are easy to collect, and the technique relies on a simple method of digestion of the organic matrix. The ease of use of FAAS should allow for more frequent monitoring of metallic levels in patients in a variety of small clinical situations, thereby offering the hope of allowing systematic tracking of metal levels as the disease progresses, or prior to the defining motor symptoms. Copyright © 2018 Elsevier GmbH. All rights reserved.

  14. Species selective preconcentration and quantification of gold nanoparticles using cloud point extraction and electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Georg, E-mail: georg.hartmann@tum.de [Department of Chemistry, Technische Universitaet Muenchen, 85748 Garching (Germany); Schuster, Michael, E-mail: michael.schuster@tum.de [Department of Chemistry, Technische Universitaet Muenchen, 85748 Garching (Germany)

    2013-01-25

    Highlights: Black-Right-Pointing-Pointer We optimized cloud point extraction and ET-AAS parameters for Au-NPs measurement. Black-Right-Pointing-Pointer A selective ligand (sodium thiosulphate) is introduced for species separation. Black-Right-Pointing-Pointer A limit of detection of 5 ng Au-NP per L is achieved for aqueous samples. Black-Right-Pointing-Pointer Measurement of samples with high natural organic mater content is possible. Black-Right-Pointing-Pointer Real water samples including wastewater treatment plant effluent were analyzed. - Abstract: The determination of metallic nanoparticles in environmental samples requires sample pretreatment that ideally combines pre-concentration and species selectivity. With cloud point extraction (CPE) using the surfactant Triton X-114 we present a simple and cost effective separation technique that meets both criteria. Effective separation of ionic gold species and Au nanoparticles (Au-NPs) is achieved by using sodium thiosulphate as a complexing agent. The extraction efficiency for Au-NP ranged from 1.01 {+-} 0.06 (particle size 2 nm) to 0.52 {+-} 0.16 (particle size 150 nm). An enrichment factor of 80 and a low limit of detection of 5 ng L{sup -1} is achieved using electrothermal atomic absorption spectrometry (ET-AAS) for quantification. TEM measurements showed that the particle size is not affected by the CPE process. Natural organic matter (NOM) is tolerated up to a concentration of 10 mg L{sup -1}. The precision of the method expressed as the standard deviation of 12 replicates at an Au-NP concentration of 100 ng L{sup -1} is 9.5%. A relation between particle concentration and the extraction efficiency was not observed. Spiking experiments showed a recovery higher than 91% for environmental water samples.

  15. Method Comparison of Neutron Activation Analysis and Atomic Absorption Spectrometry for Determination of Zinc in Food Samples

    International Nuclear Information System (INIS)

    Endah Damastuti; Syukria Kurniawati; Natalia Adventini

    2009-01-01

    Zinc as a micro nutrient, has important roles in human metabolism system. It is required by the body in appropriate amount from food intake. Due to the very low concentration of Zinc in food, high selectivity and sensitivity analysis technique is required for the determination, such as Neutron Activation Analysis (NAA) and Atomic Absorption Spectrometry (AAS). In this experiment, both methods were compared in zinc analysis of food samples. The subject of this experiment is to examine of those methods conformity and improving the technique capability in zinc analysis in food sample. Those methods were validated by analyzing zinc in SRM NIST 1548a Typical Diet and were tested its accuracy and precision. The results of Zn concentration were 25.1 ± 2.14 mg/kg by NAA and 24.1 ± 1.40 mg/kg by AAS while the certificate value was 24.6 ± 1.80 mg/kg. Percentage of relative bias, %CV, μ-test score and HORRAT(Horwitz ratio) value given by NAA were 2%, 8.5%, 0.18 and 0.9 respectively, while %relative bias, %CV, μ-test score and HORRAT value given by AAS were 2%, 5.8 %, 0.20 and 0.6 respectively. The result obtained for Zn concentration in various food samples by NAA and AAS were varied from 13.7 – 29.3 mg/kg with mean value 19.8 mg/kg and 11.2 – 26.0 mg/kg with mean value 17.3 mg/kg (author)

  16. X-ray photoelectron spectroscopy study of pyrolytically coated graphite platforms submitted to simulated electrothermal atomic absorption spectrometry conditions

    International Nuclear Information System (INIS)

    Ruiz, Frine; Benzo, Zully; Quintal, Manuelita; Garaboto, Angel; Albornoz, Alberto; Brito, Joaquin L.

    2006-01-01

    The present work is part of an ongoing project aiming to a better understanding of the mechanisms of atomization on graphite furnace platforms used for electrothermal atomic absorption spectrometry (ETAAS). It reports the study of unused pyrolytic graphite coated platforms of commercial origin, as well as platforms thermally or thermo-chemically treated under simulated ETAAS analysis conditions. X-ray photoelectron spectroscopy (XPS) was employed to study the elements present at the surfaces of the platforms. New, unused platforms showed the presence of molybdenum, of unknown origin, in concentrations up to 1 at.%. Species in two different oxidations states (Mo 6+ and Mo 2+ ) were detected by analyzing the Mo 3d spectral region with high resolution XPS. The analysis of the C 1s region demonstrated the presence of several signals, one of these at 283.3 eV related to the presence of Mo carbide. The O 1s region showed also various peaks, including a signal that can be attributed to the presence of MoO 3 . Some carbon and oxygen signals were consistent with the presence of C=O and C-O- (probably C-OH) groups on the platforms surfaces. Upon thermal treatment up to 2900 deg. C, the intensity of the Mo signal decreased, but peaks due to Mo oxides (Mo 6+ and Mo 5+ ) and carbide (Mo 2+ ) were still apparent. Thermo-chemical treatment with 3 vol.% HCl solutions and heating up to 2900 deg. C resulted in further diminution of the Mo signal, with complete disappearance of Mo carbide species. Depth profiling of unused platforms by Ar + ion etching at increasing time periods demonstrated that, upon removal of several layers of carbonaceous material, the Mo signal disappears suggesting that this contamination is present only at the surface of the pyrolytic graphite platform

  17. Determination of some heavy metal levels in soft drinks on the Ghanaian market using atomic absorption spectrometry method.

    Science.gov (United States)

    Ackah, Michael; Anim, Alfred Kwablah; Zakaria, Nafisatu; Osei, Juliet; Saah-Nyarko, Esther; Gyamfi, Eva Tabuaa; Tulasi, Delali; Enti-Brown, Sheriff; Hanson, John; Bentil, Nash Owusu

    2014-12-01

    Twenty-three soft drink samples (i.e., four pineapple-based fruit drinks, eight citrus-based fruit juices, one soya-based drink, three cola carbonated drinks, one apple-based fruit drink, and six cocktail fruit drinks) were randomly purchased from retail outlets in an urban market in Accra and analyzed for the concentrations of iron, cobalt, cadmium, zinc, lead, and copper using flame atomic absorption spectrometry. The mean concentration of iron and cadmium were 0.723 ± 0.448 mg/L and 0.032 ± 0.012 mg/L, respectively. The mean cobalt concentration was 0.071 ± 0.049 mg/L, while the mean Zn concentration in the samples was 0.060 ± 0.097 mg/L. The mean concentrations of Pb and Cu in the fruit juice samples were 0.178 ± 0.091 mg/L and 0.053 ± 0.063 mg/L respectively. About 78 % of the samples exceeded the United States Environmental Protection Agency (USEPA) maximum contaminant level of 0.3 mg/L prescribed for iron, whereas all the samples exceeded the USEPA maximum contaminant level of 0.005 mg/L prescribed for cadmium. About 91 % of the samples exceeded the EU maximum contaminant level prescribed for lead insoft drinks.

  18. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    Science.gov (United States)

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  19. Modifiers and coatings in graphite furnace atomic absorption spectrometry—mechanisms of action (A tutorial review)

    Science.gov (United States)

    Ortner, H. M.; Bulska, E.; Rohr, U.; Schlemmer, G.; Weinbruch, S.; Welz, B.

    2002-12-01

    furnace atomic absorption spectrometry (GFAAS): sample application and drying; pyrolysis; atomization. Contrary to the vast amount of literature on this topic it tried to provide the analyst working with GFAAS and in an increasing number working with Solid Sampling-GFAAS with a set of most important statements. This might spare the experimentalist a lot of useless optimization procedures but should lead him to a basic understanding of the complex phenomena taking place in his instrument and during his analytical work.

  20. Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium pyrrolidinedithioc......An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium...

  1. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6–4.3%), repeatability (4–9%), reproducibility (9–11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as

  2. Lead and cadmium in human teeth from Jordan by atomic absorption spectrometry: Some factors influencing their concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Alomary, A. [Department of Chemistry, Yarmouk University, Irbid (Jordan)]. E-mail: ahmedalomary1000@hotmail.com; Al-Momani, I.F. [Department of Chemistry, Yarmouk University, Irbid (Jordan); Massadeh, A.M. [Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid (Jordan)

    2006-10-01

    The aim of this study was to measure the concentrations of lead (Pb) and cadmium (Cd) in human teeth and to investigate the affecting factors. Teeth samples (n = 268) were collected from people living in different cities in Jordan including Amman, Zarqa, Al-Mafraq and Irbid and analyzed for Pb and Cd using atomic absorption spectrometry (AAS). A questionnaire was used to gather information on each person, such as age, sex, place where the patient lives, smoking, presence of amalgam fillings inside the mouth, and whether the patient uses toothpaste or not. The mean concentrations of Pb and Cd were 28.91 {mu}g/g and 0.44 {mu}g/g, respectively. The results indicate that there is a clear relation between Pb and Cd concentrations and the presence of amalgam fillings, smoking, and place of living. Pb was sex-dependent, whereas Cd was not. Our results show that Pb and Cd concentrations in samples obtained from Al-Mafraq and Irbid are higher than those obtained from Amman and Zarqa. Pb was highest in Mafraq, whereas Cd was highest in Irbid. The Pb and Cd concentrations in teeth from smokers (means: Pb = 31.89 {mu}g/g, Cd = 0.49 {mu}g/g) were significantly higher than those from nonsmokers (means: Pb = 24.07 {mu}g/g, Cd = 0.37 {mu}g/g). Pb and Cd concentrations in teeth of patients with amalgam fillings (means: Pb = 31.02 {mu}g/g and Cd = 0.52 {mu}g/g) were significantly higher than those from patients without amalgam fillings (means: Pb = 26.87 {mu}g/g and Cd = 0.41 {mu}g/g). Our results show that brushing the teeth daily with toothpaste does not significantly decrease the concentration of both Pb and Cd. The mean concentrations of Pb and Cd do not vary significantly between the ages 20-30, 31-40, and 41-50, but both increased rapidly at age 51-60.

  3. Effect of chemical modification on behavior of various organic vanadium forms during analysis by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Kowalewska, Zofia

    2007-01-01

    The behavior of various organic V forms dissolved in xylene during analysis by electrothermal atomic absorption spectrometry (ETAAS) was compared. The investigated analyte forms included compounds with vanadium at the oxidation state III, IV or V, as well as N, O or S atoms in molecules. Another group consisted of petroleum products containing naturally-occurring V species. Although the characteristic mass determined under different analytical conditions was in the very wide range from 11 up to 55 pg, some rules of V behavior were found. In the case of porphyrins and petroleum products, the application of Pd as a chemical modifier (xylene solution of Pd(II) acetylacetonate) seemed to be crucial. It was shown that Pd must be introduced to a furnace together with a sample. Pd injected and thermally pretreated before the sample injection was less effective for porphyrins and the petroleum products, but it increased signals of V compounds containing O as donor atom. The iodine pretreatment followed by the methyltrioctylammonium chloride (MTOACl) pretreatment was advantageous for these V forms. The air ashing in a graphite tube appeared to be important to improve decomposition of the petroleum products. No significant influence of the V oxidation state on the analytical signal was observed. The behavior of V contained in two Conostan oil standards, the single-element and the S21 multielement standard, was different in many situations. Probably, the joint action of other elements is responsible for this effect. In general, chemical modification was applied in the work for two reasons: to reduce the V volatility (in some cases losses at about 300 deg. C were observed) and to enhance the atomization efficiency. For routine analysis air ashing, modification by Pd introduced into the furnace together with the sample solution and petroleum products with known V content as standard is recommended. Using this procedure the characteristic mass varied from 16 to 19 pg for

  4. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Science.gov (United States)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6-4.3%), repeatability (4-9%), reproducibility (9-11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as straightforward

  5. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia, E-mail: e.vasileva-veleva@iaea.org

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6–4.3%), repeatability (4–9%), reproducibility (9–11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as

  6. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  7. Lead and cadmium in human teeth from Jordan by atomic absorption spectrometry: Some factors influencing their concentrations

    International Nuclear Information System (INIS)

    Alomary, A.; Al-Momani, I.F.; Massadeh, A.M.

    2006-01-01

    The aim of this study was to measure the concentrations of lead (Pb) and cadmium (Cd) in human teeth and to investigate the affecting factors. Teeth samples (n = 268) were collected from people living in different cities in Jordan including Amman, Zarqa, Al-Mafraq and Irbid and analyzed for Pb and Cd using atomic absorption spectrometry (AAS). A questionnaire was used to gather information on each person, such as age, sex, place where the patient lives, smoking, presence of amalgam fillings inside the mouth, and whether the patient uses toothpaste or not. The mean concentrations of Pb and Cd were 28.91 μg/g and 0.44 μg/g, respectively. The results indicate that there is a clear relation between Pb and Cd concentrations and the presence of amalgam fillings, smoking, and place of living. Pb was sex-dependent, whereas Cd was not. Our results show that Pb and Cd concentrations in samples obtained from Al-Mafraq and Irbid are higher than those obtained from Amman and Zarqa. Pb was highest in Mafraq, whereas Cd was highest in Irbid. The Pb and Cd concentrations in teeth from smokers (means: Pb = 31.89 μg/g, Cd = 0.49 μg/g) were significantly higher than those from nonsmokers (means: Pb = 24.07 μg/g, Cd = 0.37 μg/g). Pb and Cd concentrations in teeth of patients with amalgam fillings (means: Pb = 31.02 μg/g and Cd = 0.52 μg/g) were significantly higher than those from patients without amalgam fillings (means: Pb = 26.87 μg/g and Cd = 0.41 μg/g). Our results show that brushing the teeth daily with toothpaste does not significantly decrease the concentration of both Pb and Cd. The mean concentrations of Pb and Cd do not vary significantly between the ages 20-30, 31-40, and 41-50, but both increased rapidly at age 51-60

  8. Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Nakadi, Flávio V; Prodanov, Caroline; Boschetti, Wiliam; Vale, Maria Goreti R; Welz, Bernhard; de Andrade, Jailson B

    2018-03-01

    Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (λ = 251.611nm, 1 detection pixel, N 2 O/C 2 H 2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO 3 and HF. HR-CS GF AAS (T pyr = 1400°C, T atom = 2650°C) has evaluated Si in pyrolysis water and bio-oil at 251.611nm, and in peach pit biomass and ash at 221.174nm using SS, both wavelengths with 1 detection pixel. Rhodium (300μg) was applied as permanent modifier and 10μgPd + 6μg Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20mgkg -1 , and LOQ 0.3-20mgkg -1 , considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% mm -1 , 1.1-1.7mgkg -1 , 3.3-13mgkg -1 , and 0.41-1.4%mm -1 , in biomass, bio-oil, pyrolysis water and ash, respectively

  9. Study of absorption spectra for alkali and alkaline earth metal salts in flameless atomic absorption spectrometry using a carbon tube atomizer

    International Nuclear Information System (INIS)

    Yasuda, Seiji; Kakiyama, Hitoo

    1975-01-01

    Absorption spectra of various salts such as alkali metal salts, alkaline earth dichlorides, and ammonium halides were investigated and absorptions of some molecular species produced in the carbon tube were identified. The aqueous solution (20 μl) containing 1.0 mg/ml of each salt was placed in the carbon tube atomizer and heated in a similar manner to usual flameless atomic absorption method. D 2 -lamp was used as a continuous light source and argon gas was employed as an inert sheath gas. The spectra were obtained over the range of wavelength 200 to 350 nm. When alkali halides were feeded, the absorption spectra agreed with those of alkali halide vapors. Therefore, in such cases vapors of the alkali halides were probably produced by the sublimation or vaporization in the atomizer. The spectra of alkali perchlorates were considered to be those of alkali chlorides produced by the pyrolysis of the perchlorates in the atomizer. The absorptions of alkaline earth chlorides below 250 nm were probably due to their gaseous states. Sulfur dioxide was found to be produced by the pyrolysis of alkali sulfates, bisulfates and sulfites in the atomizer, Alkali phosphates and pyrophosphates gave almost identical spectra below 300 nm. Gamma band spectrum of nitrogen monoxide was observed from 200 to 240 nm during ashing at bout 330 0 C for alkali nitrates and nitrites. Ammonia vapor was produced from ammonium halides during drying at about 170 0 C. Although the absorptions of alkali carbonates and hydroxides were almost undetectable, the same spectra as those of alkali halides were observed by the addition of ammonium halides to the solutions of alkali compounds. This shows that alkali halides are produced in the atomizer by the addition of halide ions. (auth.)

  10. Flow injection analysis-flame atomic absorption spectrometry system for indirect determination of sulfite after on-line reduction of solid-phase manganese (IV) dioxide reactor.

    Science.gov (United States)

    Zare-Dorabei, Rouholah; Boroun, Shokoufeh; Noroozifar, Meissam

    2018-02-01

    A new and simple flow injection method followed by atomic absorption spectrometry was developed for indirect determination of sulfite. The proposed method is based on the oxidation of sulfite to sulphate ion using solid-phase manganese dioxide (30% W/W suspended on silica gel beads) reactor. MnO 2 will be reduced to Mn(II) by sample injection in to the column under acidic carrier stream of HNO 3 (pH 2) with flow rate of 3.5mLmin -1 at room temperature. Absorption measurement of Mn(II) which is proportional to the concentration of sulfite in the sample was carried out by atomic absorption spectrometry. The calibration curve was linear up to 25mgL -1 with a detection limit (DL) of 0.08mgL -1 for 400µL injection sample volume. The presented method is efficient toward sulfite determination in sugar and water samples with a relative standard deviation (RSD) less than 1.2% and a sampling rate of about 60h -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Determination of Al, Be, Cd, Co, Cr, Mn, Ni, Pb, Se and Tl in whole blood by atomic absorption spectrometry without preliminary sample digestion].

    Science.gov (United States)

    Ivanenko, N B; Ivanenko, A A; Solov'ev, N D; Navolotskiĭ, D V; Pavlova, O V; Ganeev, A A

    2014-01-01

    Methods of whole blood trace element determination by Graphite furnace atomic absorption spectrometry (in the variant of Zeeman's modulation polarization spectrometry) have been proposed. They do not require preliminary sample digestion. Furnace programs, modifiers and blood dilution factors were optimized. Seronorm™ human whole blood reference materials were used for validation. Dynamic ranges (for undiluted blood samples) were: Al 8 ¸ 210 мg/L; Be 0.3 ¸ 50 мg/L; Cd 0.2 ¸ 75 мg/L; Сo 5 ¸ 350 мg/L; Cr 10 ¸ 100 мg/L; Mn 6 ¸ 250 мg/L; Ni 10 ¸ 350 мg/L; Pb 3 ¸ 240 мg/L; Se 10 ¸ 500 мg/L; Tl 2 ¸ 600 мg/L. Precision (RSD) for the middle of dynamic range ranged from 5% for Mn to 11 for Se.

  12. Optimization of a microwave-pseudo-digestion procedure by experimental designs for the determination of trace elements in seafood products by atomic absorption spectrometry

    Science.gov (United States)

    Bermejo-Barrera, P.; Moreda-Piñeiro, A.; Muñiz-Naveiro, O.; Gómez-Fernández, A. M. J.; Bermejo-Barrera, A.

    2000-08-01

    A Plackett-Burman 2 7×3/32 design for seven factors (nitric acid concentration, hydrochloride acid concentration, hydrogen peroxide concentration, acid solution volume, particle size, microwave power, and exposure time to microwave energy) was carried out in order to find the significant variables affecting the metals acid leaching after a pseudo-digestion procedure by microwave energy from mussel. Nitric acid concentration, hydrochloride concentration or hydrogen peroxide, and exposure time to microwave energy were the most significant variables, and a 2 3+star central composite design was used for their optimization. Nitric and hydrochloric acid concentrations between 4.1 and 5.3 M, and between 2.8 and 3.8 M, respectively, were found as optimum for many elements (Ca, Cd, Cr, Cu, Fe, Mg, Mn, Pb and Zn) yielding the acid leaching process for times in the 1.2-2.2 min range. However, As was quantitatively leached with hydrochloric acid concentrations between 4.8 and 5.3 M and an exposure time of 2.0 min, while Co and Se were extracted using nitric acid (1.0 and 5.0 M, respectively) and hydrogen peroxide (5.0 M) solution and an exposure time of 2.0 min. Finally, Hg was extracted using a hydrochloric acid/hydrogen peroxide solution at 3.5:2.0 M, and also for an optimum time of microwave radiation of 1.75 min. Trace metals were determined using flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry and cold vapor — atomic absorption spectrometry. The methods were finally applied to several reference materials (DORM-1, DOLT-1 and TORT-1), achieving good accuracy.

  13. Advantages of the iridium permanent modifier in fast programs applied to trace-element analysis of plant samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vassileva, E.; Baeten, H.; Hoenig, M. [Centre for Veterinary and Agrochemical Research (CERVA), Tervuren (Belgium)

    2001-03-01

    The application of a fast program combined with the advantages of the iridium permanent modifier is proposed for trace element analysis of plant samples by electrothermal atomic absorption spectrometry (ETAAS). For two volatile elements (Cd, Pb) and two mid-refractory elements (Cr, Ni) it was demonstrated that coating of the platform or of the tube atomization area with Ir is an efficient means of improving the accuracy and precision of results. A detailed study of interference from individual main matrix components and from composite plant matrices has confirmed the usefulness of the whole approach. The validity of the method has been confirmed by analysis of eight reference plant materials. (orig.)

  14. Determination of macro- and micronutrients in plant leaves by high-resolution continuum source flame atomic absorption spectrometry combining instrumental and sample preparation strategies

    International Nuclear Information System (INIS)

    Oliveira, Silvana R.; Gomes Neto, Jose A.; Nobrega, Joaquim A.; Jones, Bradley T.

    2010-01-01

    A method for determination of B, Ca, Cu, Fe, K, Mg, Mn, Mo, P, S and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) is proposed. This method is based on special features of HR-CS-AAS, such as side pixel registration, wavelength integrated absorbance, and molecular absorption bands, for determining macro- and micronutrients in foliar analysis without requiring several different strategies for sample preparation and adjustment of the analytes concentration ranges. Plant samples were analyzed and results for certified materials were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to plant digests varied within the 82-112% interval. Relative standard deviations (n = 12) were lower than or equal to 5.7% for all analytes in all concentration ranges.

  15. Immobilized stearic acid as a new sorbent for on-line preconcentration and determination of lead by flow injection flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Dadfarnia Shayessteh

    2006-01-01

    Full Text Available The present study examines the possibility of immobilization of stearic acid on microcrystalline naphthalene for preparation of microcolumn and evaluation of its potential for adsorption and preconcentration of trace amounts of metal ions. It was found that this sorbent has high affinity for lead. Consequently, a rapid on-line preconcentration technique for the determination of lead by Flow Injection Flame Atomic Absorption Spectrometry had been devised. Preconcentration was based on accumulation of analyte on immobilized stearic acid microcolumn and subsequent elution by injection of a small volume of nitric acid (250 µL of 1 mol L-1. A sample volume of 20 mL resulted in a preconcentration factor of 84, and relative standard deviations for solutions containing 40 and 200 µg L-1 were 5.1 and 1.2%, respectively. The procedure was applied to tap water, river water, sea water, apple juice, beet leaf, urine, and certified stainless steel. The accuracy was proved by performing recovery experiments, Graphite Furnace Atomic Absorption Spectrometry measurements, and analysis of a stainless steel certified reference material.

  16. Monitoring content of cadmium, calcium, copper, iron, lead, magnesium and manganese in tea leaves by electrothermal and flame atomizer atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Prkić Ante

    2017-08-01

    Full Text Available Due to the simplicity of tea preparation (pouring hot water onto different dried herbs and its high popularity as a beverage, monitoring and developing a screening methodology for detecting the metal content is very important. The concentrations of Cd, Ca, Cu, Fe, Pb, Mg and Mn in 11 different samples of sage (Salvia officinalis L., linden (Tilia L. and chamomile (Matricaria chamomilla L. purchased at local herbal pharmacy were determined using electrothermal atomizer atomic absorption spectrometry (ETAAS and flame atomizer atomic absorption spectrometry (FAAS. The concentrations determined were: Cd (0.012 – 0.470 mg kg−1, Ca (5209 – 16340 mg kg−1, Cu (22.01 – 33.05 mg kg−1, Fe (114.2 – 440.3 mg kg−1, Pb (0.545 – 2.538 mg kg−1, Mg (2649 – 4325 mg kg−1 and Mn (34.00 – 189.6 mg kg−1. Principal Component Analysis (PCA was applied to identify factors (soil and climate influencing the content of the measured elements in herbal samples. The proposed methodology developed in this work was successfully applied to the detection of metals in herbal samples. The analysis showed that the content of toxic metals in herbal teas was below the maximum dose recommended by the World Health Organization (WHO.

  17. A novel slurry sampling analysis of lead in different water samples by electrothermal atomic absorption spectrometry after coprecipitated with cobalt/pyrrolidine dithiocarbamate complex

    Energy Technology Data Exchange (ETDEWEB)

    Baysal, A. [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak, Istanbul (Turkey); Akman, S. [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak, Istanbul (Turkey)], E-mail: akmans@itu.edu.tr; Calisir, F. [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak, Istanbul (Turkey)

    2008-10-30

    A preconcentration/separation technique based on the coprecipitation of lead with cobalt/pyrrolidine dithiocarbamate complex (Co(PDC){sub 2}) and subsequently its direct slurry sampling determination by electrothermal atomic absorption spectrometry (AAS) was described. For this purpose, at first, lead was coprecipitated with cobalt/pyrrolidine dithiocarbamate complex formed using ammonium pyrrolidine dithiocarbamate (APDC) as a chelating agent and cobalt as a carrier element. The supernatant was then separated and the slurry of the precipitate prepared in Triton X-100 was directly analyzed by electrothermal atomic absorption spectrometry with respect to lead concentration. The effects of experimental conditions on coprecipitation of lead with gathering precipitate as well as homogeneity and stability of the slurry were investigated. After the optimization of experimental parameters, a 100-fold enrichment of the analyte with quantitative recovery (>90%) and high precision (<10% R.S.D.) were obtained. By using the proposed technique, the lead concentrations in heavy matrices of Certified Sea-water and wastewater samples could be practically and rapidly determined in the range of 95% confidence level. The detection limit of the described method for lead using sample-matching blanks was 1.5 ng/L (3{sigma}, N = 10)

  18. Method development for the determination of bromine in coal using high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis

    Science.gov (United States)

    Pereira, Éderson R.; Castilho, Ivan N. B.; Welz, Bernhard; Gois, Jefferson S.; Borges, Daniel L. G.; Carasek, Eduardo; de Andrade, Jailson B.

    2014-06-01

    This work reports a simple approach for Br determination in coal using direct solid sample analysis in a graphite tube furnace and high-resolution continuum source molecular absorption spectrometry. The molecular absorbance of the calcium mono-bromide (CaBr) molecule has been measured using the rotational line at 625.315 nm. Different chemical modifiers (zirconium, ruthenium, palladium and a mixture of palladium and magnesium nitrates) have been evaluated in order to increase the sensitivity of the CaBr absorption, and Zr showed the best overall performance. The pyrolysis and vaporization temperatures were 800 °C and 2200 °C, respectively. Accuracy and precision of the method have been evaluated using certified coal reference materials (BCR 181, BCR 182, NIST 1630a, and NIST 1632b) with good agreement (between 98 and 103%) with the informed values for Br. The detection limit was around 4 ng Br, which corresponds to about 1.5 μg g- 1 Br in coal, based on a sample mass of 3 mg. In addition, the results were in agreement with those obtained using electrothermal vaporization inductively coupled plasma mass spectrometry, based on a Student t-test at a 95% confidence level. A mechanism for the formation of the CaBr molecule is proposed, which might be considered for other diatomic molecules as well.

  19. Elemental characterization of herbal medicines used in Ghana by instrumental neutron activation analysis and atomic absorption spectrometry and multivariate statistical analysis

    International Nuclear Information System (INIS)

    Ayivor, J.E.; Nyarko, B.J.B.; Dampare, S.B.; Okine, L.K.

    2010-01-01

    k 0 instrumental neutron activation analysis and atomic absorption spectrometry were applied to determine multi elements in thirteen Ghanaian herbal medicines used for the management of various diseases. Concentrations of AI, Cu, Mg, Mn and Na were determined. As, Br, K, CI, and Na were determined by short and medium irradiations at a thermal neutron flux of 5x10ncm -2 s -1 . Fe, Cr, Pb, Co, Ni, Sn, Ca, Ba, Li and Sb were determined using atomic absorption spectrometry. Ba, Cu, Li and V were present at trace levels whereas AI, CI, Na, Ca were present at major levels. K, Br, Mg, Mn, Co, Ni, Fe and Sb were also present at minor levels. The precision and accuracy of the method using real samples and standard reference materials were within ±10% of the reported value. Multivariate analytical techniques, such as cluster analysis and principal component analysis (PCA)/factor analysis (FA), have been applied to evaluate the chemical variations in the herbal medicine dataset. All the 13 samples may be grouped into two statistically significant clusters, reflecting the different chemical compositions. The concentrations of elements were within the recommended daily allowances or maximum permissible levels posing no adverse effects on human health.

  20. Investigating effects of sample pretreatment on protein stability using size-exclusion chromatography and high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Rakow, Tobias; El Deeb, Sami; Hahne, Thomas; El-Hady, Deia Abd; AlBishri, Hassan M; Wätzig, Hermann

    2014-09-01

    In this study, size-exclusion chromatography and high-resolution atomic absorption spectrometry methods have been developed and evaluated to test the stability of proteins during sample pretreatment. This especially includes different storage conditions but also adsorption before or even during the chromatographic process. For the development of the size exclusion method, a Biosep S3000 5 μm column was used for investigating a series of representative model proteins, namely bovine serum albumin, ovalbumin, monoclonal immunoglobulin G antibody, and myoglobin. Ambient temperature storage was found to be harmful to all model proteins, whereas short-term storage up to 14 days could be done in an ordinary refrigerator. Freezing the protein solutions was always complicated and had to be evaluated for each protein in the corresponding solvent. To keep the proteins in their native state a gentle freezing temperature should be chosen, hence liquid nitrogen should be avoided. Furthermore, a high-resolution continuum source atomic absorption spectrometry method was developed to observe the adsorption of proteins on container material and chromatographic columns. Adsorption to any container led to a sample loss and lowered the recovery rates. During the pretreatment and high-performance size-exclusion chromatography, adsorption caused sample losses of up to 33%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Application of dual-cloud point extraction for the trace levels of copper in serum of different viral hepatitis patients by flame atomic absorption spectrometry: a multivariate study.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem G; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal

    2014-12-10

    An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu(2+)) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu(2+) using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046μgL(-1) and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu(2+) in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu(2+) in serum samples of different viral hepatitis patients and healthy controls. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Multielement preconcentration of trace heavy metals in seawater with an emulsion containing 8-quinolinol for graphite-furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Matsumiya, Hiroaki; Kageyama, Tomohiro; Hiraide, Masataka

    2004-01-01

    A water-in-oil type emulsion containing 8-quinolinol has been used for the concentration of traces of heavy metals from seawater prior to their determinations by graphite-furnace atomic absorption spectrometry. The emulsion used was prepared by dissolving 40 mg of 8-quinolinol and 60 mg of sorbitan monooleate (Span-80) in 3.0 ml of toluene and vigorously mixing with 0.70 ml of aqueous hydrochloric acid solution (1.5 mol l -1 ) by ultrasonic irradiation. The resulting emulsion was gradually injected into 100 ml of sample solution (pH 8.5) and dispersed by stirring as numerous tiny globules. Four heavy metals (Co, Ni, Cu, and Cd) in the sample solution were quantitatively transported through the organic layer into the acidic aqueous droplets encapsulated in the emulsion. After collecting the dispersed emulsion globules, they were demulsified by heating and the heavy metals in the segregated aqueous phase were determined by atomic absorption spectrometry. Owing to the highly efficient concentration (100-fold), these heavy metals at sub-ng ml -1 levels in seawater were determined with satisfactory accuracy and precision, being confirmed with certified reference samples

  3. Hydride generation-atomic absorption spectrometry for determination of trace arsenic in draining waste water of uranium hydrometallurgical plant

    International Nuclear Information System (INIS)

    Sun Suqing; Sun Shiying; Xue Jingxia

    1986-01-01

    The arsenate is reduced to the arsenite by potassium iodide-sulfourea in dilute sulphuric acid. Then the arsenite is reduced to arsine by sodium borohydride. The arsine carried into silica tube atomizer by nitrogen is atomized at 920 deg C and determined by the homemade atomic absorption instrument. It is shown that the sensitivity of the mentioned method is 0.2 ng/ml (1% absorption). The recovery is 88-103% and the relative standard deviation is ≤ 10%

  4. Organic, inorganic and total mercury determination in fish by chemical vapor generation with collection on a gold gauze and electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Duarte, Fabio Andrei; Bizzi, Cezar Augusto; Goldschmidt Antes, Fabiane; Dressler, Valderi Luiz; Flores, Erico Marlon de Moraes

    2009-01-01

    A method for organic, inorganic and total mercury determination in fish tissue has been developed using chemical vapor generation and collection of mercury vapor on a gold gauze inside a graphite tube and further atomization by electrothermal atomic absorption spectrometry. After drying and cryogenic grinding, potassium bromide and hydrochloric acid solution (1 mol L - 1 KBr in 6 mol L - 1 HCl) was added to the samples. After centrifugation, total mercury was determined in the supernatant. Organomercury compounds were selectively extracted from KBr solution using chloroform and the resultant solution was back extracted with 1% m/v L-cysteine. This solution was used for organic Hg determination. Inorganic Hg remaining in KBr solution was directly determined by chemical vapor generation electrothermal atomic absorption spectrometry. Mercury vapor generation from extracts was performed using 1 mol L - 1 HCl and 2.5% m/v NaBH 4 solutions and a batch chemical vapor generation system. Mercury vapor was collected on the gold gauze heated resistively at 80 deg. C and the atomization temperature was set at 650 deg. C. The selectivity of extraction was evaluated using liquid chromatography coupled to chemical vapor generation and determination by inductively coupled plasma mass spectrometry. The proposed method was applied for mercury analysis in shark, croaker and tuna fish tissues. Certified reference materials were used to check accuracy and the agreement was better than 95%. The characteristic mass was 60 pg and method limits of detection were 5, 1 and 1 ng g - 1 for organic, inorganic and total mercury, respectively. With the proposed method it was possible to analyze up to 2, 2 and 6 samples per hour for organic, inorganic and total Hg determination, respectively.

  5. Fast and direct screening of copper in micro-volumes of distilled alcoholic beverages by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Ajtony, Zsolt; Laczai, Nikoletta; Dravecz, Gabriella; Szoboszlai, Norbert; Marosi, Áron; Marlok, Bence; Streli, Christina; Bencs, László

    2016-12-15

    HR-CS-GFAAS methods were developed for the fast determination of Cu in domestic and commercially available Hungarian distilled alcoholic beverages (called pálinka), in order to decide if their Cu content exceeds the permissible limit, as legislated by the WHO. Some microliters of samples were directly dispensed into the atomizer. Graphite furnace heating programs, effects/amounts of the Pd modifier, alternative wavelengths (e.g., Cu I 249.2146nm), external calibration and internal standardization methods were studied. Applying a fast graphite furnace heating program without any chemical modifier, the Cu content of a sample could be quantitated within 1.5min. The detection limit of the method is 0.03mg/L. Calibration curves are linear up to 10-15mg/L Cu. Spike-recoveries ranged from 89% to 119% with an average of 100.9±8.5%. Internal calibration could be applied with the assistance of Cr, Fe, and/or Rh standards. The accuracy of the GFAAS results was verified by TXRF analyses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Aklamati, E.K.; Mulenga, M.; Dueker, S.R.; Buchholz, B.A.; Peerson, J.M.; Kafwembe, E.; Brown, K.H.; Haskell, M.J.

    2009-01-01

    A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children 14 C 2 )-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of 14 C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting 14 C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 ± 7.1%, 76.3 ± 6.7%, and 1.9 ± 0.6%/d, respectively, for the HD-VAS and 76.5 ± 9.5%, 71.1 ± 9.4%, and 1.8 ± 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

  7. Application of Internal Standard Method for Several 3d-Transition Metallic Elements in Flame Atomic Absorption Spectrometry Using a Multi-wavelength High-resolution Spectrometer.

    Science.gov (United States)

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2017-01-01

    We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.

  8. Determination of phosphorus, sulfur and the halogens using high-temperature molecular absorption spectrometry in flames and furnaces-A review

    International Nuclear Information System (INIS)

    Welz, Bernhard; Lepri, Fabio G.; Araujo, Rennan G.O.; Ferreira, Sergio L.C.; Huang Maodong; Okruss, Michael; Becker-Ross, Helmut

    2009-01-01

    The literature about the investigation of molecular spectra of phosphorus, sulfur and the halogens in flames and furnaces, and the use of these spectra for the determination of these non-metals has been reviewed. Most of the investigations were carried out using conventional atomic absorption spectrometers, and there were in essence two different approaches. In the first one, dual-channel spectrometers with a hydrogen or deuterium lamp were used, applying the two-line method for background correction; in the second one, a line source was used that emitted an atomic line, which overlapped with the molecular spectrum. The first approach had the advantage that any spectral interval could be accessed, but it was susceptible to spectral interference; the second one had the advantage that the conventional background correction systems could be used to minimize spectral interferences, but had the problem that an atomic line had to be found, which was overlapping sufficiently well with the maximum of the molecular absorption spectrum. More recently a variety of molecular absorption spectra were investigated using a low-resolution polychromator with a CCD array detector, but no attempt was made to use this approach for quantitative determination of non-metals. The recent introduction and commercial availability of high-resolution continuum source atomic absorption spectrometers is offering completely new possibilities for molecular absorption spectrometry and its use for the determination of non-metals. The use of a high-intensity continuum source together with a high-resolution spectrometer and a CCD array detector makes possible selecting the optimum wavelength for the determination and to exclude most spectral interferences.

  9. Line strengths, A-factors and absorption cross-sections for fine structure lines in multiplets and hyperfine structure components in lines in atomic spectrometry - a user's guide

    International Nuclear Information System (INIS)

    Axner, Ove; Gustafsson, Joergen; Omenetto, Nicolo; Winefordner, James D.

    2004-01-01

    This work summarizes and elucidates a number of fundamental concepts in atomic spectrometry regarding the 'strengths' of transitions between various energy levels and states in atoms. Although several of the expressions and rules for line strengths of transitions reported here can be found, in one way or another, in various books dealing with atomic structure, atomic spectrometry or quantum mechanics, the treatment in such books can be variously complex and difficult to follow for a non-experienced reader. In addition, detailed information about transition-specific 'strengths' of transitions used to be restricted to line strengths, whereas most experiments rather need transition-specific A-factors or transition-specific absorption cross-sections. This work therefore aims at pointing out the most important aspects of the concept of 'strengths' of transitions between various energy levels and states in atoms by presenting explicit expressions for not only relative and absolute line strengths but also oscillator strengths (f-values), A-factors and absorption cross-sections, for transitions between fine structure levels within a multiplet as well as for hyperfine structure components within a line (i.e. between hyperfine structure levels), including their mutual relations, in a consistent and user-friendly manner. The work also recapitulates the most important summation rules for line strengths, oscillator strengths (f-values), A-factors and absorption cross-sections for lines within multiplets and hyperfine structure components within lines. Many of the expressions are illustrated with clear and intelligible examples. For the sake of clarity and completeness, the work also comprises a short review of the nomenclature for atomic structure and transitions

  10. High-resolution continuum source graphite furnace molecular absorption spectrometry compared with ion chromatography for quantitative determination of dissolved fluoride in river water samples.

    Science.gov (United States)

    Ley, Philip; Sturm, Manfred; Ternes, Thomas A; Meermann, Björn

    2017-12-01

    In addition to beneficial health effects, fluoride can also have adverse effects on humans, animals, and plants if the daily intake is strongly elevated. One main source of fluoride uptake is water, and thus several ordinances exist in Germany that declare permissible concentrations of fluoride in, for example, drinking water, mineral water, and landfill seepage water. Controlling the fluoride concentrations in aqueous matrices necessitate valid and fast analytical methods. In this work an alternative method for the determination of fluoride in surface waters based on high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) was applied. Fluoride detection was made possible by the formation of a diatomic molecule, GaF, and detection of characteristic molecular absorption. On HR-CS-GFMAS parameter optimization, the method was adapted to surface water sample analysis. The influence of potential main matrix constituents such as Na + , Ca 2+ , Mg 2+ , and Cl - as well as surface water sampling/storage conditions on the molecular absorption signal of GaF was investigated. Method validation demonstrated a low limit of detection (8.1 μg L -1 ) and a low limit of quantification (26.9 μg L -1 ), both sufficient for direct river water sample analysis after 0.45-μm filtration. The optimized HR-CS-GFMAS method was applied for the analysis of real water samples from the rivers Rhine and Moselle. For method validation, samples were also analyzed by an ion chromatography (IC) method. IC and HR-CS-GFMAS results both agreed well. In comparison with IC, HR-CS-GFMAS has higher sample throughput, a lower limit of detection and a lower limit of quantification, and higher selectivity, and is a very suitable method for the analysis of dissolved fluoride in river water. Graphical abstract High-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) was applied for the quantitative analysis of dissolved

  11. Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma mass spectrometry and atomic absorption spectrometry

    Science.gov (United States)

    Palmer, Christopher D.; Lewis, Miles E.; Geraghty, Ciaran M.; Barbosa, Fernando; Parsons, Patrick J.

    2006-08-01

    A biomonitoring method for the determination of Pb, Cd, and Hg at background levels in whole blood by inductively coupled plasma-mass spectrometry is described. While this method was optimized for assessing Pb, Cd and Hg at environmental levels, it also proved suitable for assessing concentrations associated with occupational exposure. The method requires as little as 200 μl of blood that is diluted 1 + 49 for direct analysis in the inductively coupled plasma-mass spectrometer. Method performance is compared to well-established AAS methods. Initial method validation was accomplished using National Institute of Standards and Technology (NIST) Standard Reference Material 966, Toxic Metals in Bovine Blood. Method detection limits (3s) are 0.05 μg dl - 1 for Pb, 0.09 μg l - 1 for Cd; and 0.17 μg l - 1 for Hg. Repeatability ranged from 1.4% to 2.8% for Pb; 3% to 10% for Cd; and 2.6% to 8.8% for Hg. In contrast, AAS method detection limits were 1 μg dl - 1 , 0.54 μg l - 1 , and 0.6 μg l - 1 , for Pb, Cd, and Hg, respectively. Further performance assessments were conducted over a 2-year period via participation in four international External Quality Assessment Schemes (EQAS) operated specifically for toxic metals in blood. This includes schemes operated by (a) the New York State Department of Health's Wadsworth Center, Albany, NY, USA (b) L'Institut National de Santé Publique du Québec, Centre de Toxicologie du Québec, Canada, (c) Friedrich-Alexander University, Erlangen, Germany, and (d) the University of Surrey, Guildford, UK Trace Elements scheme. The EQAS data reflect analytical performance for blind samples analyzed independently by both inductively coupled plasma-mass spectrometry and AAS methods.

  12. Determination of total sulfur concentrations in different types of vinegars using high resolution flame molecular absorption spectrometry.

    Science.gov (United States)

    Ozbek, Nil; Akman, Suleyman

    2016-12-15

    Total sulfur concentrations in vinegars were determined using molecular absorption of carbon monosulfide (CS) determined with a high-resolution continuum source flame atomic absorption spectrometer. The molecular absorption of CS was measured at 258.056nm in an air-acetylene flame. Due to non-spectral interference, as well as the different sensitivities to some sulfur compounds, all sulfur species were oxidized to sulfate using a HNO3 and H2O2 mixture and the analyte addition technique was applied for quantification. The limit of detection (LOD) and limit of quantification (LOQ) were 11.6 and 38.6mgL(-1), respectively. The concentrations of sulfur in various vinegars ranged from ⩽LOD to 163.6mgL(-1). Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Micro-sampling method based on high-resolution continuum source graphite furnace atomic absorption spectrometry for calcium determination in blood and mitochondrial suspensions.

    Science.gov (United States)

    Gómez-Nieto, Beatriz; Gismera, Mª Jesús; Sevilla, Mª Teresa; Satrústegui, Jorgina; Procopio, Jesús R

    2017-08-01

    A micro-sampling and straightforward method based on high resolution continuum source atomic absorption spectrometry (HR-CS AAS) was developed to determine extracellular and intracellular Ca in samples of interest in clinical and biomedical analysis. Solid sampling platforms were used to introduce the micro-samples into the graphite furnace atomizer. The secondary absorption line for Ca, located at 239.856nm, was selected to carry out the measurements. Experimental parameters such as pyrolysis and atomization temperatures and the amount of sample introduced for the measurements were optimized. Calibration was performed using aqueous standards and the approach to measure at the wings of the absorption lines was employed for the expansion of the linear response range. The limit of detection was of 0.02mgL -1 Ca (0.39ng Ca) and the upper limit of linear range was increased up to 8.0mgL -1 Ca (160ng Ca). The proposed method was used to determine Ca in mitochondrial suspensions and whole blood samples with successful results. Adequate recoveries (within 91-107%) were obtained in the tests performed for validation purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Study on the application of electrothermal atomization atomic absorption spectrometry for the determination of metallic Cu, Pb, Zn, Cd traces in sea water samples

    International Nuclear Information System (INIS)

    Nguyen Thi Kim Dung; Doan Thanh Son; Tran Thi Ngoc Diep

    2004-01-01

    The trace amount of some heavy metallic elements (Cu, Zn, Pb, Cd) in sea water samples were determined directly (without separation) and quantitatively by using Electro-Thermal Atomization Atomic Absorption Spectrometry (ETA-AAS). The effect of mainly major constituents such as Na, Mg, Ca, K, and the mutual effect of the trace elements, which were present in the matrix on the absorption intensity of each analyzed element was studied. The adding of a certain chemical modification for each trace element was also investigated in order to eliminate the overall effect of the background during the pyrolysis and atomization. The sea water sample after fitrating through a membrane with 0.45 μm-hole size was injected in to the graphite tube via an autosampler (MPE50). The absorption intensity of each element was then measured on the VARIO-6 under the optimum parameters for spectrometer such as: maximum wavelength, current of hollow cathode lamp, and that for graphite furnace such as dry temperature, pyrolysis temperature, atomization temperature, ect. The analytical procedures were set-up and applied for the determination of these above mentioned elements in the synthesized sea water sample and in the real sea water samples with high precision and accuracy. (author)

  15. Role of iron modifier on boron atomization process using graphite furnace-atomic absorption spectrometry based on speciation of iron using X-ray absorption fine structure

    Science.gov (United States)

    Yamamoto, Yuhei; Tagami, Azusa; Shiarasaki, Toshihiro; Yonetani, Akira; Yamamoto, Takashi; Imai, Shoji

    2018-04-01

    The role of an Fe modifier on boron atomization process using graphite furnace-atomic absorbance spectrometry was investigated using a spectroscopic approach. The initial state of the Fe modifier in a pyrolytic graphite (PG) furnace was trivalent. With an increase in pyrolysis temperature, the Fe modifier was reduced in a stepwise manner. Fe2O3 and Fe3O4 were dominant at pyrolysis temperatures below 1300 K. From 1300 to 1500 K, FeO was dominant. At temperatures higher than 1700 K, Fe metal was dominant. After a drying step, 17.7% of the initial B remained in the PG furnace. After the pyrolysis step at 773 K, the residual fraction of B was similar to that after the drying step. After the pyrolysis step at a temperature of 1073 K, the residual fraction was 11.7%. At pyrolysis temperatures > 1738 K, the residual fraction was <3.3% (

  16. Determination of Ultra-trace Amounts of Arsenic(III) by Flow Injection Hydride Generation Atomic Absorption Spectrometry with On-line Preconcentration by Coprecipitation with Lanthanum Hydroxide or Hafnium Hydroxide

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Sloth, Jens Jørgen; Hansen, Elo Harald

    1996-01-01

    A time-based flow-injection (FI) procedure for the determination of ultra-trace amounts of inorganic arsenic(III) is described, which combines hydride generation atomic absorption spectrometry (HG-AAS) with on-line preconcentration of the analyte by inorganic coprecipitation-dissolution in a filt......A time-based flow-injection (FI) procedure for the determination of ultra-trace amounts of inorganic arsenic(III) is described, which combines hydride generation atomic absorption spectrometry (HG-AAS) with on-line preconcentration of the analyte by inorganic coprecipitation...

  17. Strontium mono-chloride — A new molecule for the determination of chlorine using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Welz, Bernhard, E-mail: w.bernardo@terra.com.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Lopez, Alfredo H.D.; Gois, Jefferson S. de; Caramori, Giovanni F. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Borges, Daniel L.G.; Carasek, Eduardo [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil)

    2014-12-01

    A new method has been developed for the determination of chlorine in biological reference materials using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) of the strontium mono-chloride (SrCl) molecule and direct solid sample analysis. The use of the SrCl molecule for high-temperature MAS was not described up to now in the literature. Preliminary time-dependent density functional theory calculations of the SrCl structure were carried out in order to obtain reasonable estimates of the absorption spectrum of the target molecule. The calculations, which were carried out at BHandHLyp/def2-QZVP level of theory, proved a very accurate and inexpensive way to get information about the spectrum of the SrCl molecule, which enabled us to perform the Cl determination with good sensitivity and specificity. The molecular absorption of the SrCl molecule has been measured using the wavelength at 635.862 nm, and zirconium and palladium have been evaluated as the chemical modifiers in order to increase the sensitivity of the gaseous SrCl molecule generated in the graphite furnace. The pyrolysis and vaporization temperatures were 600 °C and 2300 °C, respectively. Accuracy and precision of the method have been evaluated using biological certified reference materials of both animal and plant origins, showing good agreement with the informed and certified values. Limit of detection and characteristic mass were 1.0 and 2.2 ng, respectively. The results found using HR-CS GF MAS were in agreement (95% confidence level) compared to those obtained by electrothermal vaporization-inductively coupled plasma mass spectrometry. - Highlights: • The spectrum of the SrCl molecule was calculated on a theoretical basis and found very close to the predicted wavelength. • It is the first time that the spectrum of the SrCl molecule is described and used analytically for the determination of Cl. • No spectral interferences were observed as the

  18. Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Aklamati, E K; Mulenga, M; Dueker, S R; Buchholz, B A; Peerson, J M; Kafwembe, E; Brown, K H; Haskell, M J

    2009-10-12

    A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

  19. [A comparative study of cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc in brown rice and fish by inductively coupled plasma-mass spectrometry (ICP-MS) and atomic absorption spectrometry].

    Science.gov (United States)

    Oshima, Harumi; Ueno, Eiji; Saito, Isao; Matsumoto, Hiroshi

    2004-10-01

    A study was conducted to evaluate the applicability of ICP-MS techniques for determination of metals in brown rice and fish. Cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc were determined by this method. An open digestion with nitric acid (Method A) and a rapid open digestion with nitric acid and hydrochloric acid (Method B) were used to solubilize analytes in samples, and these procedures were followed by ICP-MS analysis. Recovery of certified elements from standard reference materials by Method A and Method B ranged from 92 to 110% except for mercury (70 to 100%). Analytical results of brown rice and fish samples obtained by this ICP-MS agreed with those obtained by atomic absorption spectrometry (AAS). The results of this study demonstrate that quadrupole ICP-MS provides precise and accurate measurements of the elements tested in brown rice and fish samples.

  20. Experimental design applied to the development of a copper direct determination method in gasoline samples by graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Janyeid Karla Castro; Marques, Aldalea Lopes Brandes [Programa de Pos Graduacao em Quimica, Av. dos Portugueses S/N, Campus Bacanga, Universidade Federal do Maranhao, Sao Luis, MA (Brazil); Dantas, Allan Nilson de Sousa; Lopes, Gisele Simone [Departamento de Quimica Analitica e Fisico-Quimica, bloco 939, Campus do Pici, Universidade Federal do Ceara, 60.000-000, Fortaleza, CE (Brazil)

    2008-11-15

    The aim of this work was to develop an experimental design to optimize the direct determination of copper in gasoline by graphite furnace atomic absorption spectrometry. The optimization of the process was carried out firstly by evaluating the variables in the procedure (pyrolysis time and temperature, atomization temperature and sample volume) using a factorial design (2{sup 4}). The response surface was constructed and it presented pyrolysis optimal temperature on 800 C, sample volume of 30 {mu}L using the atomization temperature of 2500 C. The amount of copper in the gasoline samples from Sao Luis City (Brazil) varied from 3.65 to 16.21 {mu}g L{sup -} {sup 1}, with 0.65 and 1.9 {mu}g L{sup -} {sup 1} as detection limit and quantification limit, respectively. Accuracy was evaluated by a comparative procedure and the results proved the viability of copper direct determination in fuel samples. (author)

  1. Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A.; Ghaderi, Ali R. [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2008-02-15

    An on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO{sub 3} solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 μg mL{sup -1}. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

  2. Separation/preconcentration of trace Pb(II and Cd(II with 2-mercaptobenzothiazole impregnated Amberlite XAD-1180 resin and their determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Şerife Tokalıoğlu

    2017-01-01

    Full Text Available A new chelating resin, 2-mercaptobenzothiazole loaded Amberlite XAD-1180 was prepared and used for separation and preconcentration of Cd(II and Pb(II ions prior to their determinations by flame atomic absorption spectrometry. The optimum pH for simultaneous retention of the elements and the best elution means for their simultaneous elution were 9.5 and 2 mol L−1 HNO3, respectively. The detection limits for Cd(II and Pb(II were 0.35 and 5.0 μg L−1, respectively. The accuracy of the method was confırmed both by analyzing the certified reference material (RM 8704 Buffalo river sediment and performing recovery studies.

  3. Determination of Cu, Co and Pb in gasoline by electrothermal atomic absorption spectrometry using aqueous standard addition in gasoline-ethanol-water three-component system

    Energy Technology Data Exchange (ETDEWEB)

    Ozcan, Mustafa [Istanbul Technical University, Science and Letters Faculty, Chemistry Department, 34469 Maslak Istanbul (Turkey)]. E-mail: ozcanm@itu.edu.tr; Akman, Suleyman [Istanbul Technical University, Science and Letters Faculty, Chemistry Department, 34469 Maslak Istanbul (Turkey)

    2005-03-31

    Single phase gasoline-ethanol-water mixture was prepared for performing standardization with aqueous standards and for the elimination of difficulties with pipetting of gasoline. Standard addition calibration method was applied to the determination of Cu, Pb and Co in gasoline by electrothermal atomic absorption spectrometry. Good agreements were found for the analysis results of the present 'direct' method compared with those obtained by digesting gasoline in microwave furnace with nitric acid. The limit of detection values were 1.5 {mu}g kg{sup -1} Co, 2.5 {mu}g kg{sup -1} Cu and 4.0 {mu}g kg{sup -1} Pb in original gasoline samples.

  4. Direct determination of phosphorus in different food samples by means of solid sampling electrothermal atomic absorption spectrometry using Pd+Ca chemical modifier

    Energy Technology Data Exchange (ETDEWEB)

    Coskun, Nihat [Department of Chemistry, Istanbul Technical University, Science and Letter Faculty, 34469 Maslak, Istanbul (Turkey); Akman, Sueleyman [Department of Chemistry, Istanbul Technical University, Science and Letter Faculty, 34469 Maslak, Istanbul (Turkey)]. E-mail: akmans@itu.edu.tr

    2005-03-31

    In this study, direct determination of phosphorus in different food samples (milk powder, banana, and dried banana) and in various standard reference materials (apple leaves, bovine liver, pine needles) using solid sampling electrothermal atomic absorption spectrometry was investigated. Aqueous standards were used for all determinations. 5 {mu}g Pd+5 {mu}g Ca modifier mixture was used in all experiments. Pyrolysis temperature and atomization temperature were 1100 deg. C and 2500 deg. C, respectively. High background was reduced by applying a cool-down step in the furnace program. The accuracy of solid sampling results was checked by determination of the phosphorus content after dissolving samples. There was no significant error between results found by solid sampling and solution techniques. In addition solid certified materials were investigated. There were no significant differences between the phosphorus content of CRM and results obtained. The limit of detection, based on three times the standard deviation was 0.018 {mu}g P.

  5. Temperature-controlled electrothermal atomization-atomic absorption spectrometry using a pyrometric feedback system in conjunction with a background monitoring device

    Science.gov (United States)

    Van Deijck, W.; Roelofsen, A. M.; Pieters, H. J.; Herber, R. F. M.

    The construction of a temperature-controlled feedback system for electrothermal atomization-atomic absorption spectrometry (ETA-AAS) using an optical pyrometer applied to the atomization stage is described. The system was used in conjunction with a fast-response background monitoring device. The heating rate of the furnace amounted to 1400° s -1 with a reproducibility better than 1%. The precision of the temperature control at a steady state temperature of 2000°C was 0.1%. The analytical improvements offered by the present system have been demonstrated by the determination of cadmium and lead in blood and finally by the determination of lead in serum. Both the sensitivity and the precision of the method have been improved. The accuracy of the method was checked by determining the lead content for a number of scrum samples both by ETA-AAS and differential pulse anodic stripping voltametry (DPASV) and proved to be satisfactory.

  6. Direct determination of Cr and Cu in urine samples by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier (R1)

    Energy Technology Data Exchange (ETDEWEB)

    Lelis, Katia Linces Alves; Rocha, Clelia Aparecida [Instituto de Patologia Clinica Hermes Pardini, 30140-070 Belo Horizonte, MG (Brazil); Magalhaes, Cristina Goncalves; Silva, Jose Bento Borba of [Departamento de Quimica, Universidade Federal de Minas Gerais, 31270-901 Belo Horizonte, MG (Brazil)

    2002-12-01

    In this study Ru, deposited thermally on an integrated platform pyrolytic graphite tube, is proposed as a permanent modifier for the determination of Cu and Cr in urine samples by electrothermal atomic absorption spectrometry. The samples were diluted 1:1 with nitric acid (1% v/v). Pyrolysis and atomization temperatures for spiked urine samples were 1,100 C and 1,900 C respectively for Cu, and 1,400 C and 2,500 C respectively for Cr. For comparison purposes, the conventional modification with Pd+Mg was also studied. The sensitivity for Ru as permanent modifier was higher for the two analytes. The characteristic masses were 7.3 and 17.7 for Cr and Cu. The detection limits (3{sigma}) were 0.22 and 0.32 {mu}g/L, for Cr and Cu, respectively. Good agreement was obtained with certified urine samples for the two elements. (orig.)

  7. ESTIMATION OF MEASUREMENT UNCERTAINTY IN THE DETERMINATION OF Fe CONTENT IN POWDERED TONIC FOOD DRINK USING GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Harry Budiman

    2010-06-01

    Full Text Available The evaluation of uncertainty measurement in the determination of Fe content in powdered tonic food drink using graphite furnace atomic absorption spectrometry was carried out. The specification of measurand, source of uncertainty, standard uncertainty, combined uncertainty and expanded uncertainty from this measurement were evaluated and accounted. The measurement result showed that the Fe content in powdered tonic food drink sample was 569.32 µg/5g, with the expanded uncertainty measurement ± 178.20 µg/5g (coverage factor, k = 2, at confidende level 95%. The calibration curve gave the major contribution to the uncertainty of the final results.   Keywords: uncertainty, powdered tonic food drink, iron (Fe, graphite furnace AAS

  8. Ultra-Trace Determination of Copper and Silver in Environmental Samples by Using Ionic Liquid-Based Single Drop Microextraction-Electrothermal Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Abolhasani

    2013-11-01

    Full Text Available A sensitive, selective and effective ionic liquid-based single drop microextraction technique wasdeveloped by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, C6MIMPF6, coupledwith electrothermal atomic absorption spectrometry (ETAAS for the determination of copper and silver inenvironmental samples. Dithizone was used as chelating agent. Several factors that influence themicroextraction efficiency and ETAAS signal, such as pH, dithizone concentration, extraction time, amounts ofionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextractionconditions were established. In the optimum experimental conditions, the detection limits (3 s of the methodwere 4 and 8 ng L-1 and corresponding relative standard deviations (0.1 μg L-1, n = 6 were 4.2% and 4.8% forAg and Cu, respectively. The developed method was validated by analysis of a certified reference material andapplied to the determination of silver and copper.

  9. Influence of soil composition in the determination of chromium by atomic absorption spectrometry with flame air / acetylene

    International Nuclear Information System (INIS)

    Duran Sosa, Ibis; Granda Valdes, Mayra; Pomares Alfonso, Mario Simeon

    2014-01-01

    The Air-acetylene Flame Atomic Absorption determination of chromium is a complex task, being strongly influenced by sample composition and instrumental conditions. The objective of this work was to study the influence of Al, Ca, Fe, K, Mg, and Na on the absorption of chromium in the air-acetylene flame, both separately and combined in solution, when acetylene flow and burner height vary. Dissolutions of the mixtures simulated the composition of four soils from the Quibu River Basin in Havana, Cuba. Chromium absorption first increased and then decreased with increment of acetylene flow for shorter burner heights (∼ 2-4 mm); while a continuous increase was observed for larger heights (> 4 mm). This behavior was the same in the presence and absence of interfering chemical element, mentioned above. On the other hand, the dependence of the magnitude of the interference with acetylene flow and burner height was complex and dependent on the interfering element, particularly at larger heights where the behavior of Al was remarkably different. The interference of the four mixtures of Al, Ca, K, Fe, Mg and Na decreased in comparison to individual interfering effects and was less dependent on acetylene flow and burner height. Finally, a significant reduction of interference on chromium determination in soil samples was achieved by an adequate selection of acetylene flow and burner height

  10. Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Borges, Aline R.; Becker, Emilene M.; François, Luciane L.; de Jesus, Alexandre; Vale, Maria Goreti R.; Welz, Bernhard; Dessuy, Morgana B.; de Andrade, Jailson B.

    2014-11-01

    In the present work, spectral interferences on the determination of lead in fertilizer and limestone samples were investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry at the main analytical lines: 217.001 and 283.306 nm. For these investigations, samples were introduced into the furnace as slurry together with a mixture of Pd and Mg as chemical modifier. Spectral interferences were observed for some samples at both analytical lines. In order to verify whether a wet digestion procedure would avoid these interferences, a reference method for wet digestion of fertilizers was employed as an alternative sample preparation procedure. However, the same interferences were also observed in the digested samples. In order to identify and eliminate the fine-structured background using a least-squares background correction, reference spectra were generated using the combination of different species. The use of the latter technique allowed the elimination of spectral interferences for most of the investigated samples, making possible the determination of lead in fertilizer and limestone samples free of interferences. The best results were found using a reference spectrum of NH4H2PO4 at 217.001 nm, and a mixture of H2SO4 + Ca and HNO3 + Ca at the 283.306 nm line. The accuracy of the method was evaluated using a certified reference material ;Trace Elements in Multi-Nutrient Fertilizer;. Similar results were obtained using line source graphite furnace atomic absorption spectrometry with Zeeman-effect background correction, indicating that the latter technique was also capable to correct the spectral interferences, at least in part.

  11. Feasibility of dispersive liquid-liquid microextraction for extraction and preconcentration of Cu and Fe in red and white wine and determination by flame atomic absorption spectrometry

    Science.gov (United States)

    Seeger, Tassia S.; Rosa, Francisco C.; Bizzi, Cezar A.; Dressler, Valderi L.; Flores, Erico M. M.; Duarte, Fabio A.

    2015-03-01

    A method for extraction and preconcentration of Cu and Fe in red and white wines using dispersive liquid-liquid microextraction (DLLME) and determination by flame atomic absorption spectrometry (F AAS) was developed. Extraction was performed using sodium diethyldithiocarbamate as chelating agent and a mixture of 40 μL of 1,2-dichlorobenzene (extraction solvent) and 900 μL of methanol (dispersive solvent). Some parameters that influencing the extraction efficiency such as pH (2 to 5), concentration of chelating agent (0 to 2%), effect of salt addition (0 to 10%), number of washing steps (1 to 4) and centrifugation time (0 to 15 min) were studied. Accuracy was evaluated after microwave-assisted digestion in closed vessels and analytes were determined by inductively coupled plasma optical emission spectrometry. Agreement with the proposed method ranged from 91 to 110 and from 89 to 113% for Cu and Fe, respectively. Calibration of F AAS instrument was performed using analyte addition method and limits of detection were 6.3 and 2.4 μg L- 1 for Cu and Fe, respectively. The proposed method was applied for the determination of Cu and Fe in five samples of red wine and three samples of white wine, with concentration ranging from 21 to 178 μg L- 1 and from 1.38 to 3.74 mg L- 1, respectively.

  12. Determination of Iron (Fe and Calcium (Ca in NIST SRM 1566b (Oyster tissue using Flame Atomic Absorption Spectrometry (F-AAS by Standard Addition Method

    Directory of Open Access Journals (Sweden)

    Fitri Dara

    2017-03-01

    Full Text Available NIST Standard Reference Material (SRM 1566b was employed for the determination of Iron (Fe andCalcium (Ca as nutrients in food matrix using Flame Atomic Absorption Spectrometry (F-AAS. Thecertified value of SRM 1566b for Fe and Ca are 205.8 ± 6.8 mg/kg and 0.0838 ± 0.0020 (% or 838 ±20 mg/kg, respectively. This certified values are based on results obtained by single primary method(Isotope Dilution Inductively Couple Plasma Mass Spectrometry at NIST with confirmation by othermethods at National Metrology Institute of P.R. China. This paper proposed a method fordetermination of Fe and Ca in food matrix as recommended by AOAC official with a littlemodification. The method was commenced from the destruction of all organic matter by dry oxidationbefore analysis by standard addition. Under optimum condition, the results of the determination of Feand Ca in SRM 1566b were agreed well with the certificate value. This method would be useful forroutine analysis in food testing laboratories.

  13. Optimization of a field flow pre-concentration system by experimental design for the determination of copper in sea water by flow-injection-atomic absorption spectrometry

    Science.gov (United States)

    Yebra, M. C.; Carro, N.; Moreno-Cid, A.

    2002-01-01

    A Plackett-Burman 2 7×3/32 design for seven factors (sample pH, sample flow rate, eluent volume, eluent concentration, eluent flow rate, ethanol percentage in the eluent and mini-column diameter) was carried out in order to find the significant variables affecting the field flow pre-concentration system (FFPS) and the flow injection elution manifold for copper determination in seawater samples by flame atomic absorption spectrometry. By using the optimized flow systems, seawater samples were collected and pre-concentrated in situ by passing them with a peristaltic pump through a mini-column packed with Amberlite XAD-4 impregnated with the complexing agent 4-(2-pyridylazo) resorcinol. Thus, copper is pre-concentrated without the interference of the saline matrix. Once in the laboratory, the mini-columns loaded with copper are incorporated into a flow injection system and eluted with a small volume of a 40% (v/v) ethanolic solution of 3 mol l -1 hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. Analysis of certified reference materials (SLEW-3 and NASS-5) showed good agreement with the certified value.

  14. A new concept of efficient therapeutic drug monitoring using the high-resolution continuum source absorption spectrometry and the surface enhanced Raman spectroscopy

    Science.gov (United States)

    Xing, Yanlong; Fuss, Harald; Lademann, Jürgen; Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Patzelt, Alexa; Meinke, Martina C.; Jung, Sora; Esser, Norbert

    2018-04-01

    In this study, a new therapeutic drug monitoring approach has been tested based on the combination of CaF molecular absorption using high-resolution continuum source absorption spectrometry (HR-CSAS) and surface enhanced Raman spectroscopy (SERS). HR-CSAS with mini graphite tube was successfully tested for clinical therapeutic drug monitoring of the fluorine-containing drug capecitabine in sweat samples of cancer patients: It showed advantageous features of high selectivity (no interference from Cl), high sensitivity (characteristic mass of 0.1 ng at CaF 583.069 nm), low sample consumption (down to 30 nL) and fast measurement (no sample pretreatment and less than 1 min of responding time) in tracing the fluorine signal out of capecitabine. However, this technique has the disadvantage of the total loss of the drug's structure information after burning the sample at very high temperature. Therefore, a new concept of combining HR-CSAS with a non-destructive spectroscopic method (SERS) was proposed for the sensitive sensing and specific identification of capecitabine. We tested and succeed in obtaining the molecular characteristics of the metabolite of capecitabine (named 5-fluorouracil) by the non-destructive SERS technique. With the results shown in this work, it is demonstrated that the combined spectroscopic technique of HR-CSAS and SERS will be very useful in efficient therapeutic drug monitoring in the future.

  15. Solid sampling determination of total fluorine in baby food samples by high-resolution continuum source graphite furnace molecular absorption spectrometry.

    Science.gov (United States)

    Ozbek, Nil; Akman, Suleyman

    2016-11-15

    This study describes the applicability of solid sampling technique for the determination of fluorine in various baby foods via molecular absorption of calcium monofluoride generated in a graphite furnace of high-resolution continuum source atomic absorption spectrometry. Fluorine was determined at CaF wavelength, 606.440nm in a graphite tube applying a pyrolysis temperature of 1000°C and a molecule forming temperature of 2200°C. The limit of detection and characteristic mass of the method were 0.20ng and 0.17ng of fluorine, respectively. The fluorine concentrations determined in standard reference sample (bush branches and leaves) were in good agreement with the certified values. By applying the optimized parameters, the concentration of fluorine in various baby foods were determined. The fluorine concentrations were ranged from

  16. Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

    Science.gov (United States)

    Araujo, Rennan G. O.; Vignola, Fabíola; Castilho, Ivan N. B.; Borges, Daniel L. G.; Welz, Bernhard; Vale, Maria Goreti R.; Smichowski, Patricia; Ferreira, Sérgio L. C.; Becker-Ross, Helmut

    2011-05-01

    A study has been undertaken to assess the capability of high-resolution continuum source graphite furnace atomic absorption spectrometry for the determination of mercury in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling. The main Hg absorption line at 253.652 nm was used for all determinations. The certified reference material NIST SRM 1648 (Urban Particulate Matter) was used to check the accuracy of the method, and good agreement was obtained between published and determined values. The characteristic mass was 22 pg Hg. The limit of detection (3σ), based on ten atomizations of an unexposed filter, was 40 ng g - 1 , corresponding to 0.12 ng m - 3 in the air for a typical air volume of 1440 m 3 collected within 24 h. The limit of quantification was 150 ng g -1, equivalent to 0.41 ng m -3 in the air. The repeatability of measurements was better than 17% RSD (n = 5). Mercury concentrations found in filter samples loaded with APM collected in Buenos Aires, Argentina, were between air between < 0.12 ng m -3 and 1.47 ± 0.09 ng m -3. The proposed procedure was found to be simple, fast and reliable, and suitable as a screening procedure for the determination of mercury in APM samples.

  17. Development and Validation of a Sensitive Method for Trace Nickel Determination by Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Dispersive Liquid-Liquid Microextraction.

    Science.gov (United States)

    Yolcu, Şükran Melda; Fırat, Merve; Chormey, Dotse Selali; Büyükpınar, Çağdaş; Turak, Fatma; Bakırdere, Sezgin

    2018-05-01

    In this study, dispersive liquid-liquid microextraction was systematically optimized for the preconcentration of nickel after forming a complex with diphenylcarbazone. The measurement output of the flame atomic absorption spectrometer was further enhanced by fitting a custom-cut slotted quartz tube to the flame burner head. The extraction method increased the amount of nickel reaching the flame and the slotted quartz tube increased the residence time of nickel atoms in the flame to record higher absorbance. Two methods combined to give about 90 fold enhancement in sensitivity over the conventional flame atomic absorption spectrometry. The optimized method was applicable over a wide linear concentration range, and it gave a detection limit of 2.1 µg L -1 . Low relative standard deviations at the lowest concentration in the linear calibration plot indicated high precision for both extraction process and instrumental measurements. A coal fly ash standard reference material (SRM 1633c) was used to determine the accuracy of the method, and experimented results were compatible with the certified value. Spiked recovery tests were also used to validate the applicability of the method.

  18. Determination and Uncertainty Analysis of Inorganic Arsenic in Husked Rice by Solid Phase Extraction and Atomic Absorption Spectrometry with Hydride Generation.

    Science.gov (United States)

    Saxena, Sushil Kumar; Karipalli, Agnes Raju; Krishnan, Anoop A; Rangasamy, Rajesh; Malekadi, Praveen; Singh, Dhirendra P; Vasu, Vimesh; Singh, Vijay K

    2017-05-01

    This study enables the selective determination of inorganic arsenic (iAs) with a low detection limit using an economical instrument [atomic absorption spectrometer with hydride generation (HG)] to meet the regulatory requirements as per European Commission (EC) and Codex guidelines. Dry rice samples (0.5 g) were diluted using 0.1 M HNO3-3% H2O2 and heated in a water bath (90 ± 2°C) for 60 min. Through this process, all the iAs is solubilized and oxidized to arsenate [As(V)]. The centrifuged extract was loaded onto a preconditioned and equilibrated strong anion-exchange SPE column (silica-based Strata SAX 500 mg/6 mL), followed by selective and sequential elution of As(V), enabling the selective quantification of iAs using atomic absorption spectrometry with HG. In-house validation showed a mean recovery of 94% and an LOQ of 0.025 mg/kg. The repeatability (HorRatr) and reproducibility (HorRatR) values were <2, meeting the performance criteria mandated by the EC. The combined standard measurement uncertainty by this method was less than the maximum standard measurement uncertainty; thus, the method can be considered for official control purposes. The method was applied for the determination of iAs in husked rice samples and has potential applications in other food commodities.

  19. Determination of total arsenic in fish by hydride-generation atomic absorption spectrometry: method validation, traceability and uncertainty evaluation

    Science.gov (United States)

    Nugraha, W. C.; Elishian, C.; Ketrin, R.

    2017-03-01

    Fish containing arsenic compound is one of the important indicators of arsenic contamination in water monitoring. The high level of arsenic in fish is due to absorption through food chain and accumulated in their habitat. Hydride generation (HG) coupled with atomic absorption spectrometric (AAS) detection is one of the most popular techniques employed for arsenic determination in a variety of matrices including fish. This study aimed to develop a method for the determination of total arsenic in fish by HG-AAS. The method for sample preparation from American of Analytical Chemistry (AOAC) Method 999.10-2005 was adopted for acid digestion using microwave digestion system and AOAC Method 986.15 - 2005 for dry ashing. The method was developed and validated using Certified Reference Material DORM 3 Fish Protein for trace metals for ensuring the accuracy and the traceability of the results. The sources of uncertainty of the method were also evaluated. By using the method, it was found that the total arsenic concentration in the fish was 45.6 ± 1.22 mg.Kg-1 with a coverage factor of equal to 2 at 95% of confidence level. Evaluation of uncertainty was highly influenced by the calibration curve. This result was also traceable to International Standard System through analysis of Certified Reference Material DORM 3 with 97.5% of recovery. In summary, it showed that method of preparation and HG-AAS technique for total arsenic determination in fish were valid and reliable.

  20. Sequential injection on-line matrix removal and trace metal preconcentration using a PTFE beads packed column as demonstrated for the determination of cadmium by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    A sequential injection (SI) on-line matrix removal and trace metal preconcentration procedure by using a novel microcolumn packed with PTFE beads is described, and demonstrated for trace cadmium analysis with detection by electrothermal atomic absorption spectrometry (ETAAS). The analyte...

  1. Determination of As(III) and As(V) by Flow Injection-Hydride Generation-Atomic Absorption Spectrometry via On-line Reduction of As(V) by KI

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Hansen, Elo Harald

    1997-01-01

    A volume-based flow injection (FI) procedure is described for the determination and speciation of trace inorganic arsenic, As(III) and As(V), via hydride generation-atomic absorption spectrometry (HG-AAS) of As(III). The determination of total arsenic is obtained by on-line reduction of As(V) to As...

  2. On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    leached from the matrix constituents onto a Q Sepharose strong anion-exchanger freshly packed into the microconduits of the μSI-assembly; air-segmented elution of the sorbed species by a 40 μL plug of 0.5 mol L-1 NH4NO3 (pH 8) eluent; and detection by electrothermal atomic absorption spectrometry (ETAAS...

  3. Selective Flow-Injection Quantification of Ultra-trace Amounts of Cr(VI) via On-line Complexation and Preconcentration with APDC Followed by Determination by Electrothermal Atomic Absorption Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Hansen, Elo Harald

    1998-01-01

    is effected by adsorption on the inner wall of a knotted reactor made from PTFE tubing. The complex is subsequently eluted with a monosegmented discrete zone of ethanol (55 mu l), and the analyte is quantified by electrothermal atomic absorption spectrometry (ETAAS). The operations of the FI...

  4. The influence of pyrolysis and matrix modifiers on determination of Cr and Pb in sediment samples by GFAAS

    Directory of Open Access Journals (Sweden)

    Risfidian Mohadi

    2016-04-01

    Full Text Available Abstract: The Influence of pyrolysis and matrix modifiers on determination of Cr and Pb in sediment samples using graphite furnace atomic absorption spectrometry has been investigated. The sediment samples including three certified reference materials (CRMs are reported. Analyses were performed using microwave assisted dissolution. The matrix modifiers Mg(NO32, Pd+Mg(NO32 and NH4H2PO4were shown to be optimazed. The recovery for Cr and Pb in CRMs in the case of sample dissolution was found to be between 81 to 91% for Cr and 94 to 98% for Pb of the certified values, respectively. Keywords: Sediment, Pyrolysis, Matrix modifiers, Cr, Pb Abstrak (Indonesia: Pengaruh pirolisis dan matriks pengubah pada penentuan Cr dan Pb dalam sampel sedimen menggunakan tungku grafit spektroskopi serapan atom telah diteliti. Sampel sedimen termasuk tiga bahan referensi bersertifikat (CRMs dilaporkan dianalisis dengan menggunakan bantuan microwave ekstraktor. Matriks pengubah Mg(NO32, Pd+Mg(NO32 dan NH4H2PO4 telah digunakan dan menghasilkan nilai temu balik untuk Cr dan Pb dalam CRMs ditemukan antara 81-91% untuk Cr dan 94-98 % untuk Pb dari nilai sertifikat masing-masing. Katakunci: Sedimen, Pirolisis, Matrix modifiers, Cr, Pb

  5. Rapid Determination of Trace Palladium in Active Pharmaceutical Ingredients by Magnetic Solid-Phase Extraction and Flame Atomic Absorption Spectrometry

    Science.gov (United States)

    Yin, Q. H.; Zhu, D. M.; Yang, D. Z.; Hu, Q. F.; Yang, Y. L.

    2018-01-01

    Clutaraldehyde cross-linked magnetic chitosan nanoparticles were synthesized and used as an adsorbent for the dispersive solid-phase extraction of palladium in active pharmaceutical ingredients (APIs) prior to analysis by a flame atomic absorption spectrophotometer. FT-IR, X-ray diffraction, and TEM were used to characterize the adsorbent. Various parameters of experimental performance, such as adsorbent amount, pH, adsorption time, desorption solutions, coexisting ions, and adsorbent reusability, were investigated and optimized. Under the optimized conditions, good linearity was achieved in the 5.0-500 μg/L concentration range, with correlation coefficients of 0.9989. The limit of detection is 2.8 μg/L and the recoveries of spiked samples ranged from 91.7 to 97.6%. It was confirmed that the GMCNs nanocomposite was a promising adsorbing material for extraction and preconcentration of Pd in APIs.

  6. Determination of yttrium and rare-earth elements in rocks by graphite-furnace atomic-absorption spectrometry

    International Nuclear Information System (INIS)

    Sen Gupta, J.G.

    1981-01-01

    With use of synthetic solutions and several international standard reference materials a method has been developed for determining traces of Y, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in rocks by electrothermal atomization in a pyrolytically-coated graphite furnace. Depending on the element, the sensitivity is of the order of 10 -9 to 10 -12 g at 2500 0 . To avoid matrix interferences the lanthanides are separated from the common elements by co-precipitation with calcium and iron as carriers. The data for Canadian reference rock SY-2 (syenite), U.S.G.S. reference rocks W-2 (diabase), DNC-1 (diabase) and BIR-1 (basalt), and South African reference rock NIM-18/69 (carbonatite) obtained by graphite-furnace atomization are compared with the values obtained by flame atomic-absorption. The results are in good agreement with literature values. (author)

  7. Application of Factorial Designs and Simplex Optimisation in the Development of Flow Injection-Hydride Generation-Graphite Furnace Atomic Absorption Spectrometry Procedures as Demonstrated for the Determination of Trace Levels of Germanium

    DEFF Research Database (Denmark)

    Hilligsøe, Bo; Hansen, Elo Harald

    1997-01-01

    The optimisation of a volume-based FI-HG-GFAAS procedure is described for the trace determination of Ge, comprising in situ collection of the generated germane in the graphite furnace. The response function is the peak area readout (A*s). Based on a preliminary study, where factorial designs were...

  8. Determination of trace impurities of aluminium, cadmium, chromium, copper and nickel in indium phosphate by flameless atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Chruscinska, T.J.

    1990-01-01

    The sample (0.25 g) was treated with a nitric (0.9 ml) + hydrochloric (0.25 ml) acid mixture, heated to syrup under glass and then dissolved with 5 mol · 1 -1 HNO 3 (1 ml). The traces were determined in 0.2 mol · 1 -1 HNO 3 using Perkin-Elmer Model 430 Atomic Absorption Spectrometer equipped with a HGA 76B Graphite Furnace and an AS-1 Auto Sampling System. Pyrolytically coated and then tantalum treated tubes was employed. Additive errors due to contamination with, and loss of, the analyte element were controlled by estimation of the blank value and recovery. Background was corrected throughout. The background correction system efficiency was checked for the continuum background by two line method and for structured background by decreasing the slit or choosing different analytical lines. No other multiplicative (influencing the slope of the analytical curve) matrix interferences were found except for cadmium. (author). 12 refs, 4 tabs, 3 figs

  9. Measurement of endogenous lithium levels in serum and urine by electrothermal atomic absorption spectrometry: a method with potential clinical applications.

    Science.gov (United States)

    Miller, N L; Durr, J A; Alfrey, A C

    1989-11-01

    A highly sensitive flameless atomic absorption method has been adapted for the determination of endogenous trace lithium levels in serum and urine. With ammonium nitrate as the only matrix modifier, serum levels of Li as low as 0.03 mumol/liter are measured accurately and there is no requirement for standard additions. The need for background correction during analysis was clearly established, and tungsten and Zeeman-effect background corrections were compared. The tungsten correction offered superior sensitivity and linearity of standards. Recoveries in urine and serum average 94.8 +/- 7.7 and 95.3 +/- 6.1% (+/- SD), respectively. The endogenous serum Li levels were 0.16 +/- 0.08 mumol/liter for normal subjects dwelling in the Denver metropolitan area. The mean 24-h excretion rate was 5.24 +/- 1.4 mumol/day. The mean fractional excretion of endogenous Li (clearance Li/clearance creatinine) was 23.2 +/- 3.0%, a value similar to values published for exogenously administered Li and measured by conventional methods.

  10. Radiocarbon dating of archaeological samples (sambaqui) using CO(2) absorption and liquid scintillation spectrometry of low background radiation.

    Science.gov (United States)

    Mendonça, Maria Lúcia T G; Godoy, José M; da Cruz, Rosana P; Perez, Rhoneds A R

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO(2) absorption on Carbo-sorb and (14)C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H(3)PO(4) in a closed vessel in order to generate CO(2). The produced CO(2) was absorbed on Carbo-sorb. On saturation about 0.6g of carbon, as CO(2), was mixed with commercial liquid scintillation cocktail (Permafluor), and the (14)C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the (14)C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  11. Determination of molybdenum and vanadium in seawater by carbon furnace atomic absorption spectrometry with metal chelate coprecipitation

    International Nuclear Information System (INIS)

    Fujiwara, Kitao; Morikawa, Toshiki; Fuwa, Keiichiro

    1986-01-01

    Coprecipitation with metal chelate complex formation has been studied for determining molybdenum and vanadium in seawater. As coprecipitation carriers, several pairs of metal ion and chelating agent were applied : Co(II)-ammonium pyrrolydinedithiocarbamate (APDC), Cu(II)-APDC, Cr(VI)-APDC, Co(II)-sodium diethyldithiocarbamate, AI(III)-8-quinolinol, Cu(II)-cupferron, and Ni(II)-dimethylglyoxime. The procedure was as follows : A 100 ml molybdate {Mo(VI)} and metavanadate {V(V)} sample solution was taken to which were added acetate buffer solution. After addition of the carrier metal ion, the pH of the solution was adjusted and the chelating agent was then added. After stood for 1 h, the precipitate was collected by a membrane filter(pore size 0.2 μm), and dissolved in 5 ml of nitric acid(1 mol/l). It was then analyzed by graphite furnace atomic absorption spectrometer. The coprecipitation done with Co(II)-APDC surpassed the others in recoveries of molybdenum and vanadium ; which were 94 ± 3 and 96 ± 3 %, respectively. The minimum detectable amounts in the initial solution were found to be 0.05 μg/l for molybdenum and 0.1 μg/l for vanadium. Molybdenum and vanadium were determined in seawater sampled at the Japan Trench in the North Pacific Ocean. (author)

  12. Radiocarbon dating of archaeological samples (sambaqui) using CO2 absorption and liquid scintillation spectrometry of low background radiation

    International Nuclear Information System (INIS)

    Mendonca, Maria Lucia T.G.; Godoy, Jose M.; Cruz, Rosana P. da; Perez, Rhoneds A.R.

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO 2 absorption on Carbo-sorb[reg] and 14 C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H 3 PO 4 in a closed vessel in order to generate CO 2 . The produced CO 2 was absorbed on Carbo-sorb[reg]. On saturation about 0.6 g of carbon, as CO 2 , was mixed with commercial liquid scintillation cocktail (Permafluor[reg]), and the 14 C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the 14 C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained

  13. Radiocarbon dating of archaeological samples (sambaqui) using CO{sub 2} absorption and liquid scintillation spectrometry of low background radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Maria Lucia T.G. [Department of Chemistry, Pontificia Universidade Catolica does Rio de Janeiro, Rua Marques de Sao Vicente 225, Gavea, Rio de Janeiro, RJ, CEP 22453-900 (Brazil)]. E-mail: luguerra@uol.com.br; Godoy, Jose M. [Department of Chemistry, Pontificia Universidade Catolica does Rio de Janeiro, Rua Marques de Sao Vicente 225, Gavea, Rio de Janeiro, RJ, CEP 22453-900 (Brazil); Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclera, Caixa Postal 37750, Barra da Tijuca, Rio de Janeiro, RJ, CEP 22642-970 (Brazil); Cruz, Rosana P. da [Department of Chemistry, Pontificia Universidade Catolica does Rio de Janeiro, Rua Marques de Sao Vicente 225, Gavea, Rio de Janeiro, RJ, CEP 22453-900 (Brazil); Perez, Rhoneds A.R. [Museology Sector, National Museum, Federal University of Rio de Janeiro, Quinta da Boa Vista, s/no, Sao Cristovao, Rio de Janeiro, RJ, CEP 20940-040 (Brazil)

    2006-07-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO{sub 2} absorption on Carbo-sorb[reg] and {sup 14}C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H{sub 3}PO{sub 4} in a closed vessel in order to generate CO{sub 2}. The produced CO{sub 2} was absorbed on Carbo-sorb[reg]. On saturation about 0.6 g of carbon, as CO{sub 2}, was mixed with commercial liquid scintillation cocktail (Permafluor[reg]), and the {sup 14}C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the {sup 14}C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  14. Feasibility of dispersive liquid–liquid microextraction for extraction and preconcentration of Cu and Fe in red and white wine and determination by flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Seeger, Tassia S.; Rosa, Francisco C.; Bizzi, Cezar A.; Dressler, Valderi L.; Flores, Erico M.M.; Duarte, Fabio A., E-mail: fabioand@gmail.com

    2015-03-01

    A method for extraction and preconcentration of Cu and Fe in red and white wines using dispersive liquid–liquid microextraction (DLLME) and determination by flame atomic absorption spectrometry (F AAS) was developed. Extraction was performed using sodium diethyldithiocarbamate as chelating agent and a mixture of 40 μL of 1,2-dichlorobenzene (extraction solvent) and 900 μL of methanol (dispersive solvent). Some parameters that influencing the extraction efficiency such as pH (2 to 5), concentration of chelating agent (0 to 2%), effect of salt addition (0 to 10%), number of washing steps (1 to 4) and centrifugation time (0 to 15 min) were studied. Accuracy was evaluated after microwave-assisted digestion in closed vessels and analytes were determined by inductively coupled plasma optical emission spectrometry. Agreement with the proposed method ranged from 91 to 110 and from 89 to 113% for Cu and Fe, respectively. Calibration of F AAS instrument was performed using analyte addition method and limits of detection were 6.3 and 2.4 μg L{sup −1} for Cu and Fe, respectively. The proposed method was applied for the determination of Cu and Fe in five samples of red wine and three samples of white wine, with concentration ranging from 21 to 178 μg L{sup −1} and from 1.38 to 3.74 mg L{sup −1}, respectively. - Highlights: • Determination of Cu and Fe in wine using DLLME and F AAS • High preconcentration factors and low LODs were achieved. • Alternative method for the determination of Cu and Fe in wine for routine analysis.

  15. Feasibility of internal standardization in the direct and simultaneous determination of As, Cu and Pb in sugar-cane spirits by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Caldas, Naise Mary; Ruella Oliveira, Silvana; Anchieta Gomes Neto, Jose

    2009-01-01

    Bismuth and Sb were evaluated as internal standards (IS) to minimize matrix effects on the direct and simultaneous determination of As, Cu, and Pb in cachaca by graphite furnace atomic absorption spectrometry using W-coated platform plus Pd-Mg(NO 3 ) 2 as modifier. For 20 μL injected sample, calibration within the 0.5-10 μg L -1 As, 100-1000 μg L -1 Cu and 0.5-30 μg L -1 Pb intervals were established using the ratios As absorbance to Sb absorbance, Cu absorbance to Bi absorbance and Pb absorbance to Bi absorbance versus analytes concentration, respectively. Typical linear correlations of 0.998, 0.999 and 0.999 were, respectively, obtained. The proposed method was applied for direct determination of As, Cu and Pb in 10 commercial cachaca samples and results were in agreement with those obtained by inductively coupled plasma mass spectrometry at 95% confidence level. The found characteristic masses were 30 pg As, 274 pg Cu and 39 pg Pb. The useful lifetime of the graphite tube was around 760 firings. Recoveries of As, Cu and Pb added to cachaca samples varied, respectively, from 98% to 109%, 97% to 108% and 98% to 104% with internal standards and from 48% to 54%, 53% to 92% and 62% to 97% without internal standards. The limits of detection were 0.13 μg L -1 As, 22 μg L -1 Cu and 0.05 μg L -1 Pb. The relative standard deviations (n = 12) for a spiked sample containing 20 μg L -1 As, Pb and 500 μg L -1 Cu were 1.6%, 1.0%, and 1.8% with IS and 4.3%, 5.2%, and 5.5% without IS

  16. Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Aline R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Becker, Emilene M.; François, Luciane L.; Jesus, Alexandre de [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Dessuy, Morgana B., E-mail: mbdessuy@ufrgs.br [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil)

    2014-11-01

    In the present work, spectral interferences on the determination of lead in fertilizer and limestone samples were investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry at the main analytical lines: 217.001 and 283.306 nm. For these investigations, samples were introduced into the furnace as slurry together with a mixture of Pd and Mg as chemical modifier. Spectral interferences were observed for some samples at both analytical lines. In order to verify whether a wet digestion procedure would avoid these interferences, a reference method for wet digestion of fertilizers was employed as an alternative sample preparation procedure. However, the same interferences were also observed in the digested samples. In order to identify and eliminate the fine-structured background using a least-squares background correction, reference spectra were generated using the combination of different species. The use of the latter technique allowed the elimination of spectral interferences for most of the investigated samples, making possible the determination of lead in fertilizer and limestone samples free of interferences. The best results were found using a reference spectrum of NH{sub 4}H{sub 2}PO{sub 4} at 217.001 nm, and a mixture of H{sub 2}SO{sub 4} + Ca and HNO{sub 3} + Ca at the 283.306 nm line. The accuracy of the method was evaluated using a certified reference material “Trace Elements in Multi-Nutrient Fertilizer”. Similar results were obtained using line source graphite furnace atomic absorption spectrometry with Zeeman-effect background correction, indicating that the latter technique was also capable to correct the spectral interferences, at least in part. - Highlights: • Spectral interferences on the determination of lead in fertilizers and limestone. • The analytical lines at 217.001 nm and 283.306 nm using HR-CS GF AAS. • Various combinations of compounds were used to create reference spectra. • LSBC

  17. In situ emulsification microextraction using a dicationic ionic liquid followed by magnetic assisted physisorption for determination of lead prior to micro-sampling flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Shokri, Masood; Beiraghi, Asadollah; Seidi, Shahram

    2015-01-01

    For the first time, a simple and efficient in situ emulsification microextraction method using a dicationic ionic liquid followed by magnetic assisted physisorption was presented to determine trace amounts of lead. In this method, 400 μL of 1.0 mol L −1 lithium bis (trifluoromethylsulfonyl) imide aqueous solution, Li[NTf 2 ], was added into the sample solution containing 100 μL of 1.0 mol L −1 1,3-(propyl-1,3-diyl) bis (3-methylimidazolium) chloride, [pbmim]Cl 2 , to form a water immiscible ionic liquid, [pbmim][NTf 2 ] 2 . This new in situ formed dicationic ionic liquid was applied as the acceptor phase to extract the lead-ammonium pyrrolidinedithiocarbamate (Pb-APDC) complexes from the sample solution. Subsequently, 30 mg of Fe 3 O 4 magnetic nanoparticles (MNPs) were added into the sample solution to collect the fine droplets of [pbmim][NTf 2 ] 2 , physisorptively. Finally, MNPs were eluted by acetonitrile, separated by an external magnetic field and the obtained eluent was subjected to micro-sampling flame atomic absorption spectrometry (FAAS) for further analysis. Comparing with other microextraction methods, no special devices and centrifugation step are required. Parameters influencing the extraction efficiency such as extraction time, pH, concentration of chelating agent, amount of MNPs and coexisting interferences were studied. Under the optimized conditions, this method showed high extraction recovery of 93% with low LOD of 0.7 μg L −1 . Good linearity was obtained in the range of 2.5–150 μg L −1 with determination coefficient (r 2 ) of 0.9921. Relative standard deviation (RSD%) for seven repeated measurements at the concentration of 10 μg L −1 was 4.1%. Finally, this method was successfully applied for determination of lead in some water and plant samples. - Highlights: • A dicationic ionic liquid was used as the extraction solvent, for the first time. • A simple and efficient in situ emulsification microextraction

  18. On-line electrochemically controlled in-tube solid phase microextraction of inorganic selenium followed by hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Shamsayei, Maryam; Safari, Meysam; Rezaei, Fatemeh [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2016-05-30

    In this work, for the first time, a rapid, simple and sensitive microextraction procedure is demonstrated for the matrix separation, preconcentration and determination of inorganic selenium species in water samples using an electrochemically controlled in-tube solid phase microextraction (EC-in-tube SPME) followed by hydride generation atomic absorption spectrometry (HG-AAS). In this approach, in which EC-in-tube SPME and HG-AAS system were combined, the total analysis time, was decreased and the accuracy, repeatability and sensitivity were increased. In addition, to increases extraction efficiency, a novel nanostructured composite coating consisting of polypyrrole (PPy) doped with ethyleneglycol dimethacrylate (EGDMA) was prepared on the inner surface of a stainless-steel tube by a facile electrodeposition method. To evaluate the offered setup and the new PPy-EGDMA coating, it was used to extract inorganic selenium species in water samples. Extraction of inorganic selenium species was carried out by applying a positive potential through the inner surface of coated in-tube under flow conditions. Under the optimized conditions, selenium was detected in amounts as small as 4.0 parts per trillion. The method showed good linearity in the range of 0.012–200 ng mL{sup −1}, with coefficients of determination better than 0.9996. The intra- and inter-assay precisions (RSD%, n = 5) were in the range of 2.0–2.5% and 2.7–3.2%, respectively. The validated method was successfully applied for the analysis of inorganic selenium species in some water samples and satisfactory results were obtained. - Graphical abstract: An electrochemically controlled in-tube solid phase microextraction followed by hydride generation atomic absorption spectrometry was developed for extraction and determination ultra-trace amounts of Se in aqueous solutions. - Highlights: • A nanostructured composite coating consisting of PPy doped with EGDMA was prepared. • The coating was

  19. Influence of citric acid as chemical modifier for lead determination in dietary calcium supplement samples by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Cezar Paz de Mattos, Julio; Medeiros Nunes, Adriane; Figueiredo Martins, Ayrton; Luiz Dressler, Valderi; Marlon de Moraes Flores, Erico

    2005-01-01

    Citric acid was used as a chemical modifier for Pb determination by graphite furnace atomic absorption spectrometry in dietary supplement samples (calcium carbonate, dolomite and oyster shell samples) and its efficiency was compared to the use of palladium. Pyrolysis and atomization curves were established without use of chemical modifier, with the addition of 20, 100 and 200 μg of citric acid, and with 3 μg of palladium. The citric acid modifier made possible the interference-free Pb determination in the presence of high concentrations of Ca and Mg nitrates. Acid sample digestion involving closed vessels (microwave-assisted and conventional heating) and acid attack using polypropylene vessels at room temperature were compared. All digestion procedures presented similar results for calcium carbonate and dolomite samples. However, for oyster shell samples accurate results were obtained only with the use of closed vessel systems. Analyte addition and matrix-matched standards were used for calibration. The characteristic mass for Pb using citric acid and palladium were 16 and 25 pg, respectively. The relative standard deviation (RSD) was always less than 5% when citric acid was used. The relative and absolute limits of detection were 0.02 μg g -1 and 8 pg with citric acid and 0.1 μg g -1 and 44 pg with the Pd modifier, respectively (n = 10, 3σ). The recovery of Pb in spiked calcium supplement samples (10 μg l -1 ) was between 98% and 105%. With the use of 100 μg of citric acid as chemical modifier, problems such as high background absorption and high RSD values were minimized in comparison to the addition of 3 μg of palladium

  20. Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    dos Santos, Lisia M G; Araujo, Rennan G O; Welz, Bernhard; Jacob, Silvana do C; Vale, Maria Goreti R; Becker-Ross, Helmut

    2009-04-30

    Cadmium and iron are antagonistic elements in the sense that they produce different effects in the human body. Both elements have to be determined routinely in grain products, cadmium because of its toxicity, and iron because all grain products, according to Brazilian law, have to contain a minimum of 42 mg kg(-1) Fe to combat anemia. A routine screening method has been developed for the quasi simultaneous determination of cadmium and iron using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling. The primary absorption line at 228.802 nm has been used for Cd, and an adjacent secondary line at 228.726 nm for the determination of Fe. Various chemical modifiers have been investigated, and a mixture of tungsten and iridium, applied as a permanent modifier, showed the best performance; it stabilized Cd up to a pyrolysis temperature of 700 degrees C and did not over-stabilize Fe. Two atomization temperatures were used sequentially, 1700 degrees C for Cd and 2600 degrees C for Fe, because of their significantly different volatilities. The characteristic masses obtained were 0.9 pg for Cd and 1.2 ng for Fe. The limits of detection (3 sigma, n=10) were 0.6 microg kg(-1) for Cd and 0.5 mg kg(-1) for Fe. The relative standard deviation ranged from 3 to 7% for Cd and from 4 to 13% for Fe, which is satisfactory for the purpose. The accuracy of the method was confirmed by the analysis of three certified reference materials; the results were in agreement with the certified values at a 95% confidence interval. The Cd content in the investigated grain products was between 0.9 and 10.5 microg kg(-1), but most of them did not contain the required minimum amount of iron.

  1. Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Rennan G.O., E-mail: rgoa01@terra.com.br [Laboratorio de Quimica Analitica Ambiental, Departamento de Quimica, Universidade Federal de Sergipe, Campus Sao Cristovao, 49.100-000, Sao Cristovao, SE (Brazil); Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Vignola, Fabiola; Castilho, Ivan N.B. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Borges, Daniel L.G.; Welz, Bernhard [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Vale, Maria Goreti R. [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Instituto de Quimica, Universidade Federal do Rio Grande do Sul, 91501-970 Porto Alegre, RS (Brazil); Smichowski, Patricia [Comision Nacional de Energia Atomica (CNEA) and Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina); Ferreira, Sergio L.C. [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Instituto de Quimica, Universidade Federal da Bahia, 40170-290, Salvador, BA (Brazil); Becker-Ross, Helmut [Leibniz-Institut fuer Analytische Wissenschaften-ISAS-e.V., Department Berlin, 12489 Berlin (Germany)

    2011-05-15

    A study has been undertaken to assess the capability of high-resolution continuum source graphite furnace atomic absorption spectrometry for the determination of mercury in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling. The main Hg absorption line at 253.652 nm was used for all determinations. The certified reference material NIST SRM 1648 (Urban Particulate Matter) was used to check the accuracy of the method, and good agreement was obtained between published and determined values. The characteristic mass was 22 pg Hg. The limit of detection (3{sigma}), based on ten atomizations of an unexposed filter, was 40 ng g{sup -1}, corresponding to 0.12 ng m{sup -3} in the air for a typical air volume of 1440 m{sup 3} collected within 24 h. The limit of quantification was 150 ng g{sup -1}, equivalent to 0.41 ng m{sup -3} in the air. The repeatability of measurements was better than 17% RSD (n = 5). Mercury concentrations found in filter samples loaded with APM collected in Buenos Aires, Argentina, were between < 40 ng g{sup -1} and 381 {+-} 24 ng g{sup -1}. These values correspond to a mercury concentration in the air between < 0.12 ng m{sup -3} and 1.47 {+-} 0.09 ng m{sup -3}. The proposed procedure was found to be simple, fast and reliable, and suitable as a screening procedure for the determination of mercury in APM samples.

  2. Fast sequential multi-element determination of major and minor elements in environmental samples and drinking waters by high-resolution continuum source flame atomic absorption spectrometry.

    Science.gov (United States)

    Gómez-Nieto, Beatriz; Gismera, Ma Jesús; Sevilla, Ma Teresa; Procopio, Jesús R

    2015-01-07

    The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Determination of arsenic and cadmium in shellfish samples by graphite furnace atomic absorption spectrometry using matrix modifier

    International Nuclear Information System (INIS)

    Villalobos Aranda, Juan; Cortez Diaz, Mirella

    2003-01-01

    Serious problems of environmental contamination due to the activity of the man exist at the present time. Where the greater impact is the produced one by heavy metals that go to the sea. Where the shellfish can collect some of them, the highly toxic ones, since these are bioaccumulation of these metals. Therefore one becomes necessary to count with the reliable analytical procedures to determine these elements. The purpose of this work is to present the determination of arsenic and cadmium in shellfish, by spectroscopy of atomic absorption with graphite furnace. For each determined element, solutions of nickel and phosphate like matrix modifiers were used respectively The validation was made using a Reference Certified Material, Oyster ' Tissue 156 (National Institute of Standards and Technology). The sample previously was digested in triplicate by two consecutive days, with nitric acid in a pressure digestion system DAB 11. For each element it was evaluated: limit of detection and quantification, sensitivity, repeatability, linear, slope rank and uncertainty. In addition, the obtained results were compared with the certified values of the certified material of reference using like statistical tools the tests of Student and Fisher. In both tests the calculated values were smaller to the shown ones in table, for degrees of freedom with 95% of confidence. Thus it was verified that it does not exist significant differences between the precision and the average values of the results obtained with respect to the values of the certified material. In addition, the obtained parameters are appropriate for the determination of these trace elements in this type of environmental sample (author)

  4. Quantifying uncertainty in the measurement of arsenic in suspended particulate matter by Atomic Absorption Spectrometry with hydride generator

    Directory of Open Access Journals (Sweden)

    Ahuja Tarushee

    2011-04-01

    Full Text Available Abstract Arsenic is the toxic element, which creates several problems in human being specially when inhaled through air. So the accurate and precise measurement of arsenic in suspended particulate matter (SPM is of prime importance as it gives information about the level of toxicity in the environment, and preventive measures could be taken in the effective areas. Quality assurance is equally important in the measurement of arsenic in SPM samples before making any decision. The quality and reliability of the data of such volatile elements depends upon the measurement of uncertainty of each step involved from sampling to analysis. The analytical results quantifying uncertainty gives a measure of the confidence level of the concerned laboratory. So the main objective of this study was to determine arsenic content in SPM samples with uncertainty budget and to find out various potential sources of uncertainty, which affects the results. Keeping these facts, we have selected seven diverse sites of Delhi (National Capital of India for quantification of arsenic content in SPM samples with uncertainty budget following sampling by HVS to analysis by Atomic Absorption Spectrometer-Hydride Generator (AAS-HG. In the measurement of arsenic in SPM samples so many steps are involved from sampling to final result and we have considered various potential sources of uncertainties. The calculation of uncertainty is based on ISO/IEC17025: 2005 document and EURACHEM guideline. It has been found that the final results mostly depend on the uncertainty in measurement mainly due to repeatability, final volume prepared for analysis, weighing balance and sampling by HVS. After the analysis of data of seven diverse sites of Delhi, it has been concluded that during the period from 31st Jan. 2008 to 7th Feb. 2008 the arsenic concentration varies from 1.44 ± 0.25 to 5.58 ± 0.55 ng/m3 with 95% confidence level (k = 2.

  5. Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil.

    Science.gov (United States)

    Frentiu, Tiberiu; Ponta, Michaela; Hategan, Raluca

    2013-03-01

    The aim of this paper was the validation of a new analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals (Ag, Cd, Co, Cr, Cu, Ni, Pb and Zn) in soil after microwave assisted digestion in aqua regia. Determinations were performed on the ContrAA 300 (Analytik Jena) air-acetylene flame spectrometer equipped with xenon short-arc lamp as a continuum radiation source for all elements, double monochromator consisting of a prism pre-monocromator and an echelle grating monochromator, and charge coupled device as detector. For validation a method-performance study was conducted involving the establishment of the analytical performance of the new method (limits of detection and quantification, precision and accuracy). Moreover, the Bland and Altman statistical method was used in analyzing the agreement between the proposed assay and inductively coupled plasma optical emission spectrometry as standardized method for the multielemental determination in soil. The limits of detection in soil sample (3σ criterion) in the high-resolution continuum source flame atomic absorption spectrometry method were (mg/kg): 0.18 (Ag), 0.14 (Cd), 0.36 (Co), 0.25 (Cr), 0.09 (Cu), 1.0 (Ni), 1.4 (Pb) and 0.18 (Zn), close to those in inductively coupled plasma optical emission spectrometry: 0.12 (Ag), 0.05 (Cd), 0.15 (Co), 1.4 (Cr), 0.15 (Cu), 2.5 (Ni), 2.5 (Pb) and 0.04 (Zn). Accuracy was checked by analyzing 4 certified reference materials and a good agreement for 95% confidence interval was found in both methods, with recoveries in the range of 94-106% in atomic absorption and 97-103% in optical emission. Repeatability found by analyzing real soil samples was in the range 1.6-5.2% in atomic absorption, similar with that of 1.9-6.1% in optical emission spectrometry. The Bland and Altman method showed no statistical significant difference between the two spectrometric

  6. On-line dynamic two-dimensional admicelles solvent extraction coupled to electrothermal atomic absorption spectrometry for determination of chromium(VI) in drinking water

    International Nuclear Information System (INIS)

    Nan Jing; Yan Xiuping

    2005-01-01

    An on-line dynamic two-dimensional admicelles solvent extraction system was coupled to electrothermal atomic absorption spectrometry (ETAAS) for determination of Cr(VI) in drinking water. As a two-dimensional solvent, admicelles were on-line-prepared by passing cetyltrimethylammonium bromide (CTAB) through a microcolumn packed with silica gel. The analyte Cr(VI) was on-line-complexed with pyrrolidine dithiocarbamate (PDC), and the resulting Cr(VI)-PDC was effectively adsolubilized in the admicelles of the microcolumn, and then quantitatively eluted with 30 μl of acetonitrile for ETAAS determination. All the procedures including the formation and decomposition of admicelles and ETAAS determination were performed on-line, ensuring automatic determination of Cr(VI) in drinking water with a high precision. With a consumption of 2.1 ml sample solution, a detection limit (3σ) of 3.0 ng l -1 , and an enhancement factor of 32 were obtained at a sample throughput of 31 samples h -1 . The precision (R.S.D.) for 11 replicate measurements of 50 ng l -1 Cr(VI) was 2.5%. The developed methodology was demonstrated to be reliable and sensitive for automatic determination of ultratrace Cr(VI) in bottled drinking water samples

  7. Automated magnetic sorbent extraction based on octadecylsilane functionalized maghemite magnetic particles in a sequential injection system coupled with electrothermal atomic absorption spectrometry for metal determination.

    Science.gov (United States)

    Giakisikli, Georgia; Anthemidis, Aristidis N

    2013-06-15

    A new automatic sequential injection (SI) system for on-line magnetic sorbent extraction coupled with electrothermal atomic absorption spectrometry (ETAAS) has been successfully developed for metal determination. In this work, we reported effective on-line immobilization of magnetic silica particles into a microcolumn by the external force of two strong neodymium iron boron (NdFeB) magnets across it, avoiding the use of frits. Octadecylsilane functionalized maghemite magnetic particles were used as sorbent material. The potentials of the system were demonstrated for trace cadmium determination in water samples. The method was based on the on-line complex formation with diethyldithiocarbamate (DDTC), retention of Cd-DDTC on the surface of the MPs and elution with isobutyl methyl ketone (IBMK). The formation mechanism of the magnetic solid phase packed column and all critical parameters (chemical, flow, graphite furnace) influencing the performance of the system were optimized and offered good analytical characteristics. For 5 mL sample volume, a detection limit of 3 ng L(-1), a relative standard deviation of 3.9% at 50 ng L(-1) level (n=11) and a linear range of 9-350 ng L(-1) were obtained. The column remained stable for more than 600 cycles keeping the cost down in routine analysis. The proposed method was evaluated by analyzing certified reference materials and natural waters. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. A novel separation/preconcentration technique based on ultrasonic dispersion liquid-liquid microextraction for determination of trace cobalt by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Jingci Li

    2012-12-01

    Full Text Available An improved method for the determination of trace cobalt in water samples has been developed using ultrasonic dispersion liquid-liquid microextraction (US-DLLME prior to flame atomic absorption spectrometry (FAAS analysis. In this method, cobalt was extracted into the fine droplets of carbon tetrachloride after chelate formation with the water soluble ligand, ammonium pyrrolidine dithiocarbamate (APDC. The fine droplets of carbon tetrachloride were formed and dispersed in the aqueous sample with the help of ultrasonic waves which accelerated the formation of the fine cloudy solution without using disperser solvents. Under optimum conditions, the calibration curve was linear in the range of 2.5-500 μg L-1, with a detection limit of 0.8 μg L-1. The relative standard deviation (RSD for ten replicate measurements of 20 and 500 μg L-1 of cobalt were 3.3 and 2.2%. This proposed method was successfully applied to tap water, river water, and sea water, and accuracy was assessed through the analysis of certified reference water or recovery experiments. Operation simplicity, low cost, high enrichment factor, and low consumption of the extraction solvent are the main advantages of the proposed method.DOI: http://dx.doi.org/10.4314/bcse.v26i1.2

  9. Cloud Point Extraction for the Determination of Trace Amounts of Cobalt in Water and Food Samples by Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Shangzhi Wang

    2013-01-01

    Full Text Available A cloud point extraction (CPE procedure which was developed for the separation and preconcentration of trace amounts of cobalt is combined with flame atomic absorption spectrometry (FAAS to determine trace amounts of cobalt in water and food samples. The procedure is based on the formation of the hydrophobic complex between Co(II and 4-methoxy-2-sulfo-benzenediazoaminoazo-benzene (MOSDAA followed by its extraction into a Triton X-114 surfactant-rich phase. The parameters such as pH of sample, concentrations of MOSDAA and Triton X-114, equilibrium temperature, and equilibrium time, which affect both complexation and extraction, are optimized. Under the selected optimum conditions, the preconcentration of 10.0 mL, 0.1 μg mL−1 Co(II solution results in a limit of detection of 0.47 ng mL−1 (3σ and an enrichment factor of 19. A relative standard deviation of 2.78% (,  μg mL−1 for the determination of Co(II is obtained. The proposed method was applied for the determination of trace amounts of cobalt in river water and millet samples with satisfactory results.

  10. Accuracy of a method based on atomic absorption spectrometry to determine inorganic arsenic in food: Outcome of the collaborative trial IMEP-41.

    Science.gov (United States)

    Fiamegkos, I; Cordeiro, F; Robouch, P; Vélez, D; Devesa, V; Raber, G; Sloth, J J; Rasmussen, R R; Llorente-Mirandes, T; Lopez-Sanchez, J F; Rubio, R; Cubadda, F; D'Amato, M; Feldmann, J; Raab, A; Emteborg, H; de la Calle, M B

    2016-12-15

    A collaborative trial was conducted to determine the performance characteristics of an analytical method for the quantification of inorganic arsenic (iAs) in food. The method is based on (i) solubilisation of the protein matrix with concentrated hydrochloric acid to denature proteins and allow the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS). The seven test items used in this exercise were reference materials covering a broad range of matrices: mussels, cabbage, seaweed (hijiki), fish protein, rice, wheat, mushrooms, with concentrations ranging from 0.074 to 7.55mgkg(-1). The relative standard deviation for repeatability (RSDr) ranged from 4.1 to 10.3%, while the relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 22.8%. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Evaluation of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for direct determination of chromium in medicinal plants

    International Nuclear Information System (INIS)

    Virgilio, Alex; Nóbrega, Joaquim A.; Rêgo, Jardes F.; Neto, José A. Gomes

    2012-01-01

    A method for Cr determination in medicinal plants using direct solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry was developed. Modifiers were dispensable. Pyrolysis and atomization temperatures were 1500 °C and 2400 °C, respectively. Slopes of calibration curves (50–750 pg Cr, R 2 > 0.999) using aqueous and solid standards coincides in 96%, indicated feasibility of aqueous calibration for solid sampling of medicinal plants. Accuracy was checked by analysis of four plant certified reference materials. Results were in agreement at 95% confidence level with certified and non-certified values. Ten samples of medicinal plants were analyzed and Cr contents were in the 1.3–17.7 μg g −1 Cr range. The highest RSD (n = 5) was 15.4% for the sample Melissa officinalis containing 13.9 ± 2.1 μg g −1 Cr. The limit of detection was 3.3 ng g −1 Cr. - Highlights: ► Direct solid sampling is first time employed for Cr in plant materials. ► Calibration curves with liquids and solids are coincident. ► Microanalysis of plants for Cr is validated by reference materials. ► The proposed HR-CS GF AAS method is environmental friendly.

  12. Optimization of cloud point extraction procedure with response surface methodology for quantification of iron by means of flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Abdolmohammad-Zadeh Hossein

    2013-01-01

    Full Text Available A simple micelle-mediated phase separation method has been developed for the pre-concentration of trace levels of iron as a prior step to determination by flame atomic absorption spectrometry (FAAS. The method is based on the cloud point extraction (CPE of iron using non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5 without adding any chelating agent. Several variables affecting the extraction efficiency were studied and optimized utilizing central composite design (CCD and three levels full factorial design. Under the optimum conditions, the limit of detection (LOD, limit of quantification (LOQ and pre-concentration factor were 1.5 μg L-1, 5.0 μg L-1 and 100, respectively. The relative standard deviation (RSD for six replicate determinations at 50 μg L−1 Fe(III level was 1.97%. The calibration graph was linear in the rage of 5-100 μg L-1, with a correlation coefficient of 0.9921. The developed method was validated by the analysis of two certified reference materials and applied successfully to the determination of trace amounts of Fe(III in water and rice samples.

  13. Determination of trace amounts of rare earth elements in samarium, terbium and disprosium oxides by graphite furnace atomic-absorption spectrometry

    International Nuclear Information System (INIS)

    Dantas, E.S.K.

    1990-01-01

    A graphite furnace atomic-absorption spectrometry method for the determination of neodymium, europium, terbium, dysprosium and yttrium at trace level in samarium oxide; of samarium, europium, dysprosium, holmium, erbium and yttrium in terbium oxide and of europium, terbium, holmium, erbium and yttrium in dysprosium oxide was established. The best pyrolysis and atomization temperatures were determined for each lanthanide considered. Calibration curves were obtained for the pure elements, for binary mixtures formed by the matrix and each of the lanthanides studied and, finally, for the complex mixtures constituted by the matrix and all the other lanthanide of the group under scrutiny. This study has been carried out to examine the interference of the presence of one lanthanide on the behaviour of the other, since a lack of linearity on the calibration curves has been observed in some cases. Detection and determination limits have been determined as well. The detection limits encountered were within the range 0.002 to 0.3% for different elements. The precision of the method expressed as the relative standard deviation was calculated for each element present in each of the matrices studied. The conclusion arrived at is that the method can be applied for determining the above mentioned lanthanides present in the matrices studied with purity up to 99.50%. (author)

  14. Application of experimental design in a method for screening sediments for global determination of organic tin by electrothermal atomic absorption spectrometry (ETAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Arambarri, I.; Garcia, R.; Millan, E. [Dept. de Quimica Aplicada, Univ. del Pais Vasco, San Sebastian (Spain)

    2001-12-01

    An experimental design was developed to obtain a simple procedure for global determination of organic tin compounds in sediment. Sediment was extracted by a two-phase method and tin was determined in the organic extract by electrothermal atomic absorption spectrometry (ETAAS), with palladium as chemical modifier. A Plackett-Burman design for screening and a fractional central composite design (CCD) for optimizing were used for evaluation of the effects of several variables. The results showed that sediment mass, volume and concentration of extracting acid, pyrolysis and atomization temperatures, and modifier concentration affect the determination. Reference material PACS-2 was analyzed to evaluate the procedure. It was possible to extract 82% of the organotin content certified in the reference sediment. The limit of detection (LOD) was 0.08 {mu}g g{sup -1}and the relative standard deviation was 4%. The method was applied to the analysis of estuarine superficial sediments from Gipuzkoa (Spain). The organotin content of these samples ranged from 0.7 to 7.7 {mu}g g {sup -1}, as tin, on a dry-weight basis. (orig.)

  15. Continuous ultrasound-assisted extraction of cadmium from legumes and dried fruit samples coupled with on-line preconcentration-flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yebra, M.C.; Cancela, S. [University of Santiago de Compostela, Department of Analytical Chemistry, Nutrition and Bromatology, Santiago de Compostela (Spain)

    2005-06-01

    Cadmium was continuously extracted with diluted nitric acid from legumes and dried fruit samples using a simple, rapid and continuous ultrasound-assisted extraction system. A minicolumn packed with a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was placed between the extraction unit and the detector for cadmium preconcentration. The cadmium content in the acid extract was retained into the minicolumn, and elution was carried out with hydrochloric acid, with this trace metal continuously monitored by flame atomic absorption spectrometry. An experimental design (Plackett-Burman 2{sup 6} x 3/16) was used to optimize the continuous leaching procedure and the preconcentration step. The method allowed a total sampling frequency of 10 and 14 samples per hour for legumes and dried fruit, respectively. The procedure displayed good precision (2.0 and 2.5%, respectively, expressed as relative standard deviations) for samples containing 0.202{+-}0.005 {mu}g g{sup -1} Cd (broad bean) and 0.239{+-}0.004 {mu}g g{sup -1} Cd (peanut). Detection limits of 0.014 {mu}g g{sup -1} Cd for 60 mg of legume samples and 0.011 {mu}g g{sup -1} Cd for 80 mg of dried fruit samples were obtained. The method was successfully applied to the determination of trace amounts of cadmium in legumes and dried fruit samples. (orig.)

  16. Photoassisted vapor generation in the presence of organic acids for ultrasensitive determination of Se by electrothermal-atomic absorption spectrometry following headspace single-drop microextraction

    International Nuclear Information System (INIS)

    Figueroa, Raul; Garcia, Monica; Lavilla, Isela; Bendicho, Carlos

    2005-01-01

    A method is described for the determination of selenium at the pg/mL level by electrothermal-atomic absorption spectrometry using in situ photogeneration of Se vapors, headspace sequestration onto an aqueous microdrop containing Pd(II) and subsequent injection in a graphite tube. Several organic acids (formic, oxalic, acetic, citric and ethylenediaminetetraacetic) have been tried for photoreduction of Se(IV) into volatile Se compounds under UV irradiation. Experimental variables such as UV irradiation time, organic acid concentration, Pd(II) concentration in the drop, sample and drop volumes, extraction time and pH were fully optimized. Low-molecular weight acids such as formic and acetic provided optimal photogeneration of volatile Se species at a 0.6 mol/L concentration. Citric and ethylenediaminetetraacetic acid allowed to use a concentration as low as 1 mmol/L, but extraction times were longer than for formic and acetic acids. Photogeneration of (CH 3 ) 2 Se from Se(IV) in the presence of acetic acid provided a detection limit of 20 pg/mL, a preconcentration factor of nearly 285 and a precision, expressed as relative standard deviation, of 4%. Analytical performance seemed to depend not only on the photogeneration efficiency obtained with each acid but also on the stability of the vapors in the headspace. The method showed a high freedom from interferences caused by saline matrices, but interferences were observed for transition metals at a relatively low concentration

  17. Ultrasound-assisted extraction technique for establishing selenium contents in breast cancer biopsies by Zeeman-electrothermal atomic absorption spectrometry using multi-injection

    International Nuclear Information System (INIS)

    Lavilla, I.; Mosquera, A.; Millos, J.; Cameselle, J.; Bendicho, C.

    2006-01-01

    A solid-liquid extraction method is developed to establish the contents of selenium in breast cancer biopsies. The method is based on the ultrasound-assisted extraction of selenium from pretreated biopsies prior to Se determination by atomic absorption spectrometry with longitudinal-Zeeman background correction. Fifty-one breast biopsies were collected from the Cies Hospital (Vigo, Spain), 32 of which correspond to tumor tissue and 19 to normal tissue (parenchyma). Difficulties arising from the samples analyzed, i.e. small samples mass (50-100 mg), extremely low Se contents and sample texture modification including tissue hardening due to formaldehyde preservation are addressed and overcome. High intensity sonication using a probe together with addition of hydrogen peroxide succeeded in completely extracting Se from biopsies. The multiple injection technique was useful to tackle the low Se contents present in some biopsies. The detection limit was 25 ng g -1 of Se and the precision, expressed as relative standard deviation, was less than 10%. Se contents ranged from 0.08 to 0.4 μg g -1 for parenchyma samples and from 0.09 to 0.8 μg g -1 for tumor samples. In general, Se levels in tumor biopsies were higher as compared with the adjacent normal tissue in 19 patients by a factor of up to 6. Analytical data confirmed Se accumulation in the breast tumors

  18. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pena, Francisco; Lavilla, Isela; Bendicho, Carlos

    2008-01-01

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 μg/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters

  19. Simultaneous determination of Cr, Ni and V in urine by electrothermal atomic absorption spectrometry (ET AAS); Determinacion simultanea de Cr, Ni y V en orina mediante et aas

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, Maria A.; Hermida, Jeymi [Universidad Central de Venezuela, Caracas (Venezuela, Bolivarian Republic of). Escuela de Quimica. Centro de Quimica Analitica

    2011-07-01

    A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 deg C, respectively, using 15 {mu}g de Mg(NO{sub 3}){sub 2} as chemical modifier. Characteristics mass of 14, 6 and 220 {rho}g and detection limits of the method of 0.07, 0.38 and 0.75 {mu}g L{sup -1} were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 {mu}g L{sup -1} was observed for Cr and V, respectively, and not detectable levels for Ni. (author)

  20. Dispersive liquid-liquid microextraction based on solidification of floating organic drop for preconcentration and determination of trace amounts of copper by flame atomic absorption spectrometry.

    Science.gov (United States)

    Karadaş, Cennet; Kara, Derya

    2017-04-01

    A novel, simple, rapid, sensitive, inexpensive and environmentally friendly dispersive liquid-liquid microextraction method based on the solidification of a floating organic drop (DLLME-SFO) was developed for the determination of copper by flame atomic absorption spectrometry (FAAS). N-o-Vanillidine-2-amino-p-cresol was used as a chelating ligand and 1-undecanol was selected as an extraction solvent. The main parameters affecting the performance of DLLME-SFO, such as sample pH, volume of extraction solvent, extraction time, concentration of the chelating ligand, salt effect, centrifugation time and sample volume were investigated and optimized. The effect of interfering ions on the recovery of copper was also examined. Under the optimum conditions, the detection limit (3σ) was 0.93μgL -1 for Cu using a sample volume of 20mL, yielding a preconcentration factor of 20. The proposed method was successfully applied to the determination of Cu in tap, river and seawater, rice flour and black tea samples as well as certified reference materials. Copyright © 2016. Published by Elsevier Ltd.

  1. Preconcentration of trace amounts of lead in water samples with cetyltrimethylammonium bromide coated magnetite nanoparticles and its determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-11-01

    Full Text Available A sensitive and simple magnetic solid phase extraction procedure was presented for the preconcentration of lead ions in environmental water samples. In the present study, lead ions form complexes with 1-(2-pyridilazo-2-naphthol reagent (PAN in basic medium, and then are quantitatively extracted to the surface of cetyltrimethylammonium bromide (CTAB-coated magnetite nanoparticles (Fe3O4 NPs. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v HCl in methanol prior to its analysis by flame atomic absorption spectrometry (FAAS. The pH of sample, concentrations of PAN, amounts of CTAB and Fe3O4 NPs, sample volume and desorption conditions were optimized. Under optimum conditions, the calibration curve was linear in the range of 0.05–100 ng mL−1 with R2 = 0.9996. Detection and quantification limits of the proposed method were 0.005 and 0.05 ng mL−1, respectively. Enhancement factor of 1050 was achieved using this method to extract 1000 mL of different environmental water samples. Compared with conventional solid phase extraction methods, the advantages of this method still include easy preparation of sorbents, short times of sample pre-treatment, high extraction yield, and high breakthrough volume. It shows great analytical potential in preconcentration of lead from large volume water samples.

  2. Analysis of heavy metals and minerals elements in the turmeric using Total-Reflection X-ray Fluorescence analysis technique and Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Andriamisetra, V.M.Z.

    2014-01-01

    Currently, many studies demonstrate anti-cancer and anti-inflammatory benefits of turmeric. The aims of this work is to perform analysis of metals such as calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, bromine, rubidium, strontium, cadmium and lead in the turmeric collected from various places in Madagascar. The analysis by total reflection X-ray fluorescence technique is used to determine the concentrations of heavy metals, while the atomic absorption spectrometry is used for the determination of trace elements. Analysis results show that the concentration of calcium in the turmeric is very high, its average concentration is 1025.8 mg.kg -1 . The average concentrations of manganese, of copper and of iron are respectively 44.7 mg.kg -1 ; 19.7 mg.kg -1 and 53.6 mg.kg -1 . The average concentrations of zinc, of rubidium and of strontium are respectively 17.3 mg.kg -1 ; 35.2 mg.kg -1 and 21.7 mg.kg -1 [fr

  3. Investigation of chemical modifiers for sulfur determination in diesel fuel samples by high-resolution continuum source graphite furnace molecular absorption spectrometry using direct analysis

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Charles S. [Instituto Federal Sul-rio-grandense, Câmpus Pelotas, Pelotas, RS (Brazil); Universidade Federal do Rio Grande do Sul, Instituto de Química, Porto Alegre, RS (Brazil); Vale, Maria Goreti R. [Universidade Federal do Rio Grande do Sul, Instituto de Química, Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Universidade Federal de Santa Catarina, Departamento de Química, Florianópolis, SC (Brazil); Andrade, Jailson B. [Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Dessuy, Morgana B., E-mail: mbdessuy@ufrgs.br [Universidade Federal do Rio Grande do Sul, Instituto de Química, Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil)

    2015-06-01

    High-resolution continuum source graphite furnace molecular absorption spectrometry has been applied for sulfur determination in diesel fuel. The sharp rotational lines of the carbon monosulfide molecule (formed during the vaporization step) were used to measure the absorbance. The analytical line at 258.056 nm was monitored using the sum of three pixels. Different chemical modifiers were investigated and the mixture of palladium and magnesium was used as chemical modifier in combination with iridium as permanent modifier. L-Cysteine was chosen as sulfur standard and the calibration was done against aqueous standard solutions. The proposed method was applied for the analyses of four diesel samples: two S10 samples and two S500 samples. The trueness of the method was checked with a certified reference material (CRM) of sulfur in diesel fuel (NIST 2724b). Accurate results, for samples and CRM, were achieved after a dilution with propan-1-ol. The following figures of merit were obtained: characteristic mass of 17 ± 3 ng, limit of detection and limit of quantification of 1.4 mg kg{sup −1} and 4.7 mg kg{sup −1}, respectively. - Highlights: • Ir, Ru and Zr were investigated as permanent modifiers. • Ca, Mg, Pd and Pd/Mg were investigated as modifiers in solution. • Indirect determination of sulfur monitoring the molecular absorbance of the CS • Direct analysis of diesel samples using a dilution in propan-1-ol.

  4. Distribution of heavy metals in Lumbricus terrestris, Aporrectodea longa and A. rosea measured by atomic absorption and X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Andersen, C.; Laursen, J.

    1982-01-01

    Distribution of Ca, Pb, Cd, Zn, Fe and Mn has been investigated in the earthworm species Lumbricus terrestris, Aporectodea longa and A. rosea by atomic absorption and X-ray fluorescence spectrometry measurements. The material of L. terrestris originated from the garden of the Royal Veterinary and Agricultural University in central Copenhagen. Material of the other two species was sampled in sewage sludge treated plots. It was found that lead and cadmium are accumulated in the gut wall and from here transferred to waste nodules (brown bodies). In L. terrestris more lead was transferred to waste nodules than cadmium. Also large amounts of zinc were accumulated in the gut wall. Analyses of L. terrestris calciferous glands showed that these take part in regulation and excretion of a number of heavy metals. Lead and cadmium content was low in the ventral nerve chord and seminal vesicles. A. longa with poorly developed calciferous glands seems to rely more on waste nodule formation in the ultimate immobilization of lead. (author)

  5. A Green Preconcentration Method for Determination of Cobalt and Lead in Fresh Surface and Waste Water Samples Prior to Flame Atomic Absorption Spectrometry

    Science.gov (United States)

    Naeemullah; Kazi, Tasneem Gul; Shah, Faheem; Afridi, Hassan Imran; Khan, Sumaira; Arian, Sadaf Sadia; Brahman, Kapil Dev

    2012-01-01

    Cloud point extraction (CPE) has been used for the preconcentration and simultaneous determination of cobalt (Co) and lead (Pb) in fresh and wastewater samples. The extraction of analytes from aqueous samples was performed in the presence of 8-hydroxyquinoline (oxine) as a chelating agent and Triton X-114 as a nonionic surfactant. Experiments were conducted to assess the effect of different chemical variables such as pH, amounts of reagents (oxine and Triton X-114), temperature, incubation time, and sample volume. After phase separation, based on the cloud point, the surfactant-rich phase was diluted with acidic ethanol prior to its analysis by the flame atomic absorption spectrometry (FAAS). The enhancement factors 70 and 50 with detection limits of 0.26 μg L−1 and 0.44 μg L−1 were obtained for Co and Pb, respectively. In order to validate the developed method, a certified reference material (SRM 1643e) was analyzed and the determined values obtained were in a good agreement with the certified values. The proposed method was applied successfully to the determination of Co and Pb in a fresh surface and waste water sample. PMID:23227429

  6. Slurry analysis of cadmium and copper collected on 11-mercaptoundecanoic acid modified TiO2 core-Au shell nanoparticles by flame atomic absorption spectrometry.

    Science.gov (United States)

    Gunduz, S; Akman, S; Kahraman, M

    2011-02-15

    Separation/preconcentration of copper and cadmium using TiO(2) core-Au shell nanoparticles modified with 11-mercaptoundecanoic acid and their slurry analysis by flame atomic absorption spectrometry were described. For this purpose, at first, titanium dioxide nanoparticles were coated with gold shell by reducing the chloroauric acid with sodium borohydride and then modified with 11-mercaptoundecanoic acid. The characterization of modified nanoparticles was performed using ultra-violet spectroscopy and dynamic light scattering. Copper and cadmium were then collected on the prepared sorbent by batch method. The solid phase loaded with the analytes was separated by centrifugation and the supernatant was removed. Finally, the precipitate was slurried and directly aspirated into the flame for the determination of analytes. Thus, elution step and its all drawbacks were eliminated. The effects of pH, amount of sorbent, slurry volume, sample volume and diverse ions on the recovery were investigated. After optimization of experimental parameters, the analytes in different certified reference materials and spiked water samples were quantitatively recovered with 5% RSD. The analytes were enriched up to 20-fold. Limits of detection (N=10, 3σ) for copper and cadmium were 0.28 and 0.15 ng mL(-1), respectively. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Investigation of interference mechanisms of nickel chloride on copper determination and of colloidal palladium as modifier in electrothermal atomic absorption spectrometry using a dual cavity platform

    Energy Technology Data Exchange (ETDEWEB)

    Akman, Suleyman [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, Maslak-Istanbul (Turkey); Welz, Bernhard [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900 Florianopolis-SC (Brazil)]. E-mail: welz@qmc.ufsc.br; Tokman, Nilgun [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, Maslak-Istanbul (Turkey)

    2005-10-01

    The interference of nickel chloride on the determination of copper by electrothermal atomic absorption spectrometry was investigated using a specially designed dual cavity platform (DCP), which allows the analyte and interferent to vaporize from separate cavities, so that gas and condensed phase interferences can be distinguished to some extent. It was found that, when low pyrolysis temperatures were used, the interference of nickel chloride on copper originated from the formation of copper chloride in the condensed phase, which is not efficiently dissociated in the atomization stage. Alternately, when analyte and interferent were in separate cavities of the DCP, a gas-phase reaction between copper and chlorine in the atomization stage resulted in a similar signal depression. When higher pyrolysis temperatures were used, interference could be attributed to losses of volatile copper chloride in the pyrolysis stage. These losses were more pronounced when analyte and interferent were in separate cavities of the DCP, indicating again a gas-phase reaction between copper and chlorine, as well as a protective action of nickel oxide, when analyte and interferent were mixed. Colloidal palladium used as modifier removed the chloride interference independent of the pyrolysis temperature applied, when copper and nickel chloride were mixed. Colloidal palladium also increased the integrated absorbance for copper by 40-50%, even when analyte and modifier were in separate cavities of the DCP, indicating a strong gas-phase interaction between copper atoms and the modifier through adsorption/desorption processes.

  8. Slurry analysis of cadmium and copper collected on 11-mercaptoundecanoic acid modified TiO{sub 2} core-Au shell nanoparticles by flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gunduz, S. [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak-Istanbul (Turkey); Akman, S., E-mail: akmans@itu.edu.tr [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469 Maslak-Istanbul (Turkey); Kahraman, M. [Yeditepe University, Faculty of Engineering and Architecture, Department of Genetics and Bioengineering, 34755 Kayisdagi-Istanbul (Turkey)

    2011-02-15

    Separation/preconcentration of copper and cadmium using TiO{sub 2} core-Au shell nanoparticles modified with 11-mercaptoundecanoic acid and their slurry analysis by flame atomic absorption spectrometry were described. For this purpose, at first, titanium dioxide nanoparticles were coated with gold shell by reducing the chloroauric acid with sodium borohydride and then modified with 11-mercaptoundecanoic acid. The characterization of modified nanoparticles was performed using ultra-violet spectroscopy and dynamic light scattering. Copper and cadmium were then collected on the prepared sorbent by batch method. The solid phase loaded with the analytes was separated by centrifugation and the supernatant was removed. Finally, the precipitate was slurried and directly aspirated into the flame for the determination of analytes. Thus, elution step and its all drawbacks were eliminated. The effects of pH, amount of sorbent, slurry volume, sample volume and diverse ions on the recovery were investigated. After optimization of experimental parameters, the analytes in different certified reference materials and spiked water samples were quantitatively recovered with 5% RSD. The analytes were enriched up to 20-fold. Limits of detection (N = 10, 3{sigma}) for copper and cadmium were 0.28 and 0.15 ng mL{sup -1}, respectively.

  9. The use of silver nanoparticles as an effective modifier for the determination of arsenic and antimony by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gunduz, S., E-mail: semagunduz@itu.edu.t [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak-Istanbul (Turkey); Akman, S., E-mail: akmans@itu.edu.t [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak-Istanbul (Turkey); Baysal, A., E-mail: baysalas@itu.edu.t [Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, 34469, Maslak-Istanbul (Turkey); Kahraman, M., E-mail: mkahraman@yeditepe.edu.t [Yeditepe University, Faculty of Engineering and Architecture, Department of Genetics and Bioengineering, 34755 Kayisdagi-Istanbul (Turkey)

    2010-04-15

    Silver nanoparticles (AgNPs) were proposed as a new chemical modifier for the elimination of interferences when determining arsenic and antimony in aqueous NaCl or Na{sub 2}SO{sub 4} solutions and in sea-water by electrothermal atomic absorption spectrometry. For this purpose, the AgNPs were prepared simply by reducing silver nitrate with sodium citrate. The effects of pyrolysis and atomization temperatures and the amounts of interferents and modifiers on the sensitivities of these elements were investigated. In the presence of the proposed modifier, a pyrolysis temperature of at least 1100 deg. C for arsenic and 900 deg. C for antimony could be applied without the loss of analytes, and the interferences were greatly reduced to allow for interference-free determination. The detection limits (N = 10, 3sigma) for arsenic and antimony were 0.022 ng and 0.046 ng, respectively. AgNPs are cheaper and more available compared to many other modifiers. No background was detected, and the blank values were negligible.

  10. Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Martinis, Estefania M.; Berton, Paula [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, CC. 131, M 5502 IRA Mendoza (Argentina); Olsina, Roberto A. [INQUISAL-CONICET, Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, San Luis (Argentina); Altamirano, Jorgelina C. [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, CC. 131, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@lab.cricyt.edu.ar [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, CC. 131, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2009-08-15

    A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C{sub 4}mim][PF{sub 6}]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 {mu}l of 9.0 mol L{sup -1} hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3 ng L{sup -1} and the relative standard deviation (RSD) for 10 replicates at 1 {mu}g L{sup -1} Hg{sup 2+} was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).

  11. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Gil, F., E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  12. Separation and determination of copper in bottled water samples by combination of dispersive liquid--liquid microextraction and microsample introduction flame atomic absorption spectrometry.

    Science.gov (United States)

    Citak, Demirhan; Tuzen, Mustafa

    2013-01-01

    A new and simple method for the determination of trace amounts of Cu(II) was developed by combination of dispersive liquid-liquid microextraction (DLLME) preconcentration and microsample introduction flame atomic absorption spectrometry. In this method, ethanol and chloroform were chosen as disperser and extraction solvents, respectively, and 1-nitroso-2-naphthol was used as the complexing agent. The factors affecting the extraction efficiency and determination of Cu(II), including extraction and disperser solvent nature and volume, concentration of the complexing agent, pH of the solution, extraction time, and matrix ions, were investigated. Under optimal conditions, the LOD for Cu(II) was 0.95 microg/L with a preconcentration factor of 70. The RSD was 1.9%. The accuracy of the developed DLLME method was verified by determination of Cu(II) in a certified reference material (NRCC-SLRS-4 river water). The relative error was -3.31%. The developed preconcentration procedure was successfully applied to the analysis of bottled drinking water samples.

  13. A novel fiber-packed column for on-line preconcentration and speciation analysis of chromium in drinking water with flame atomic absorption spectrometry.

    Science.gov (United States)

    Monasterio, Romina P; Altamirano, Jorgelina C; Martínez, Luis D; Wuilloud, Rodolfo G

    2009-02-15

    A novel on-line preconcentration and determination system based on a fiber-packed column was developed for speciation analysis of Cr in drinking water samples prior to its determination by flame atomic absorption spectrometry (FAAS). All variables involved in the development of the preconcentration method including, pH, eluent type, sample and eluent flow rates, interfering effects, etc., were studied in order to achieve the best analytical performance. A preconcentration factor of 32 was obtained for Cr(VI) and Cr(III). The levels of Cr(III) species were calculated by difference of total Cr and Cr(VI) levels. Total Cr was determined after oxidation of Cr(III) to Cr(VI) with hydrogen peroxide. The calibration graph was linear with a correlation coefficient of 0.999 at levels near the detection limit and up to at least 50 microg L(-1). The relative standard deviation (R.S.D.) was 4.3% (C=5 microg L(-1) Cr(VI), n=10, sample volume=25 mL). The limit of detection (LOD) for both Cr(III) and Cr(VI) species was 0.3 microg L(-1). Verification of the accuracy was carried out by the analysis of a standard reference material (NIST SRM 1643e "Trace elements in natural water"). The method was successfully applied to the determination of Cr(III) and Cr(VI) species in drinking water samples.

  14. Portable Solid Phase Extraction of Copper, Cadmium and Lead Using Analig ME-02 Chelating Resin and Their Determination by Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Mohamed Abousa Gaza

    2014-06-01

    Full Text Available The adsorption of metallic elements on the solid phase chelating resins is probably the most effective separation and preconcentration methods. In this work, portable Solid phase extraction (SPE was constructed using a commercially available plastic syringe containing certain amount of the Analiq ME-02 chelating resin. The ability of this portable SPE was evaluated through adsorption-desorption process of copper, lead, and cadmium prior their determination by atomic absorption spectrometry (AAS. Some parameters affecting the adsorption-desorption of these heavy metal ions on the Analiq ME-02, which include effect of pH and concentration of eluent ((HNO3, were investigated in detail. It was found that quantitative adsorptions (> 90% of copper, lead, and cadmium are obtained at all pHs (4- 8 examined, whereas 1 M HNO3 was found to be effective for the desorption of these metals with the recoveries in the range of 93 -114%. Such results indicated that Analig ME-02 has excellent chelating ability (pH-independent for the adsorption of copper, lead, and cadmium, while portable SPE system provides easiness and effectiveness for collection/preconcentation of metallic elements

  15. Sea sponge as a low cost biosorbent for solid phase extraction of some heavy metal ions and determination by flame atomic absorption spectrometry.

    Science.gov (United States)

    Karatepe, Aslihan; Soylak, Mustafa

    2014-01-01

    A new, easy, sensitive, and environmentally friendly separation and preconcentration method was developed to determine Cu(ll), Fe(lll), Pb(ll), and Ni(ll) at trace levels by use of a column filled with sea sponge without any complexing reagent, and atomic absorption spectrometry. The influences of analytical parameters, such as pH of the solutions, type of eluent, volume of sample, solution and eluent flow rates, and diverse ions, were examined for the quantitative recoveries of the analyte ions. The metal ions were eluted from the column by using 2 M HNO3. Accurate results were found for spiked samples after applying the preconcentration method. The LOD values were found to be between 1.5 and 5.6 μg/L based on three times the SD of the blanks. The method has been successfully applied to determine Cu(ll), Fe(lll), Pb(ll), and Ni(ll) ions in tap water samples, mineral water samples, and a certified reference material.

  16. Combination of flotation and flame atomic absorption spectrometry for determination, preconcentration and separation of trace amounts of metal ions in biological samples.

    Science.gov (United States)

    Ghaedi, Mehrorang; Niknam, Khodabakhsh; Nasiri kokhdan, Syamak; Soylak, Mustafa

    2013-05-01

    An efficient enrichment procedure based on the combination of flame atomic absorption spectrometry (FAAS) and flotation for determination of Cd(2+), Ag(+) and Zn(2+) ions in various biological samples using new collector is studied. The influence of pH, amount of 2-(((1H-benzo[d]imidazol-2-yl)methoxy)methyl)-1H-benzo[d]imidazole (HBIMMHBI) as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates on the extraction efficiency were evaluated and optimized. It is ascertained that under study metal ions is preconcentrated simultaneously from matrix in the presence of 0.005 M HBIMMHBI, 0.085% (w/v) of SDS form 750 mL at pH 6.5. The floated complexes metal ions eluted quantitatively with 6 mL of 1.0 M HNO3 in methanol lead to achieve preconcentration factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL(-1), with recoveries more than 95% and relative SD lower than 4%.

  17. Preconcentration procedure using in situ solvent formation microextraction in the presence of ionic liquid for cadmium determination in saline samples by flame atomic absorption spectrometry.

    Science.gov (United States)

    Mahpishanian, Shokouh; Shemirani, Farzaneh

    2010-07-15

    A simple in situ solvent formation microextraction methodology based on the application of ionic liquid (IL) as an extractant solvent and sodium hexafluorophosphate (NaPF(6)) as an ion-pairing agent was proposed for the preconcentration of trace levels of cadmium. In this method cadmium was complexed with O,O-diethyldithiophosphate (DDTP) and extracted into an ionic liquid phase. After phase separation, the enriched analyte in the final solution is determined by flame atomic absorption spectrometry (FAAS). ISFME is a simple and rapid method for extraction and preconcentration of metal ions from sample solutions containing a high concentration of salt. Some effective factors that influence the microextraction efficiency were investigated and optimized. Under the optimum experimental conditions, the limit of detection (3 s) and the enhancement factor were 0.07 microg L(-1) and 78, respectively. The relative standard deviation (R.S.D.) was obtained 2.42%. The accuracy of the method was confirmed by analyzing certified reference materials for trace elements in seawater (GBW (E) 080040 seawater). The proposed method was successfully applied for the determination of cadmium in water samples and food grade salts. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.

  18. Sulfur-nanoparticle-based method for separation and preconcentration of some heavy metals in marine samples prior to flame atomic absorption spectrometry determination.

    Science.gov (United States)

    Ghanemi, Kamal; Nikpour, Yadollah; Omidvar, Omid; Maryamabadi, Ammar

    2011-07-15

    The application of sulfur-nanoparticle-loaded alumina as an efficient adsorbent for the solid-phase extraction (SPE) and determination of trace amounts of Cd, Cu, Zn, and Pb ions was investigated in marine samples using flame atomic absorption spectrometry (FAAS). The nanometer-sized sulfur particles were synthesized in situ, physically loaded onto alumina microparticles, and the parameters influencing the preconcentration of the analytes, such as the pH, solution flow rate and volume, eluent solution, and interfering ions, were examined. The results showed that the optimal conditions for quantitative recovery of the metal ions by adsorption and elution on the sulfur nanoparticles (SNPs) was achieved by employing a flow rate of 15 mL min(-1), a pH of 8.5 for the sample solutions, and an eluent composed of 3.0 mol L(-1) HNO(3) in methanol. The detection limits of this method for Cd, Zn, Cu, and Pb ions were 0.30, 0.21, 0.24, and 0.63 μg L(-1) (n=10), respectively. Application of the proposed method to the analysis of fish certified reference material (DORM-3) produced results that were in good agreement with the certified values. The proposed method was also successfully applied to the determination of analytes in marine samples, including seawater, fish, and oysters. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Modified carbon nanotubes as a sorbent for solid-phase extraction of gold, and its determination by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Moghaddam, Firouzeh Hassani; Behzadi, Mansoureh; Naghizadeh, Matin; Taher, Mohammad Ali

    2015-01-01

    A simple, sensitive and accurate method was developed for solid-phase extraction and preconcentration of trace levels of gold in various samples. It is based on the adsorption of gold on modified oxidized multi-walled carbon nanotubes prior to its determination by graphite furnace atomic absorption spectrometry. The type and volume of eluent solution, sample pH value, flow rates of sample and eluent, sorption capacity and breakthrough volume were optimized. Under these conditions, the method showed linearity in the range of 0.2–6.0 ng L −1 with coefficients of determination of >0.99 in the sample. The relative standard deviation for seven replicate determinations of gold (at a level of 0.6 ng L −1 ) is ±3.8 %, the detection limit is 31 pg L −1 (in the initial solution and at an S/N ratio of 3; for n = 8), and the enrichment factor is 200. The sorption capacity of the modified MWCNTs for gold(III) is 4.15 mg g −1 . The procedure was successfully applied to the determination of gold in (spiked) water samples, human hair, human urine and standard reference material with recoveries ranging from 97.0 to 104.2 %. (author)

  20. Preconcentrative separation of chromium(III) species from chromium(VI) by cloud point extraction and determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yildiz, Z.; Arslan, G.; Tor, A.

    2011-01-01

    We describe a high-throughput technique for the determination of chromium species in water samples by flame atomic absorption spectrometry (FAAS) after preconcentrative separation of Cr(III) species from Cr(VI) by cloud point extraction (CPE) using diethyldithiocarbamate (DDTC) as the chelating agent and the nonionic surfactant Triton X-100 as the extractant. The Cr(III)-DDTC complex is extracted if the temperature is higher than the CPE temperature of Triton X-100, while Cr(VI) remains in the aqueous phase. The Cr(III) in the surfactant phase was analyzed by FAAS, and the concentration of Cr(VI) was calculated by subtraction of Cr(III) from total chromium which was directly determined by FAAS. The effect of pH, concentration of chelating agent, surfactant, and equilibration temperature were investigated. The detection limit for Cr(III) was 0. 08 μg L -1 with an enrichment factor of 98, and the relative standard deviation was 1. 2% (n = 3, c = 100 μg L -1 ). A certified reference material and several water samples were analyzed with satisfactory results. (author)

  1. Removal, preconcentration and determination of Ni(II from different environmental samples using modified magnetite nanoparticles prior to flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Karimi

    2015-11-01

    Full Text Available In this paper, a simple, fast and reliable solid phase extraction (SPE method to determine Ni(II using dimethylglyoxim/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles (DMG/SDS-ACMNPs as a new adsorbent prior to its determination by flame atomic absorption spectrometry (FAAS is described. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD of nickel(II ions were 320 (for 800 mL of sample solution, 4.6 ng mL−1, 10.0–100.0 ng mL−1 and 1.9% (for 50.0 ng mL−1, n = 7, respectively. This method avoided the time-consuming column-passing process of loading large volume samples in traditional SPE through the rapid isolation of DMG/SDS-ACMNPs with an adscititious magnet. The proposed method was successfully applied to determine the content of Ni(II in soil, spinach, tomato, black tea, tobacco and different water samples and suitable recoveries were obtained.

  2. Determination of total arsenic levels by hydride generation atomic absorption spectrometry in foods from south-east Spain: estimation of daily dietary intake.

    Science.gov (United States)

    Delgado-Andrade, C; Navarro, M; López, H; López, M C

    2003-10-01

    The total concentration of arsenic in different foods from south-east Spain was determined by hydride generation atomic absorption spectrometry. Mineralization was carried out with an HNO(3)-HClO(4) mixture in a thermostated sand bath. Arsenic determination was performed by the standard addition method. Analyses of NIST and CBR-CEC reference materials demonstrated the reliability and accuracy of the technique. The highest arsenic levels were found in seafood, cereals, meat and meat by-products. In meat and meat by-products, the total arsenic measured in meat was significantly higher than that in sausages (pcereals, arsenic concentrations in corn and white rice samples were significantly higher (pcheese were statistically lower than those in other dairy products (p<0.01). New data have been provided on the total arsenic content of a variety of foods in Spain, which is important for making exposure estimates. The estimated daily intake of total arsenic in the Spanish diet was 221 microg As day(-1).

  3. Preconcentration of Copper Using 1,5-Diphenyl Carbazide as the Complexing Agent via Dispersive Liquid-Liquid Microextraction and Determination by Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Reyhaneh Rahnama

    2013-01-01

    Full Text Available We report a simple and sensitive microextraction system for the preconcentration and determination of Cu (II by flame atomic absorption spectrometry (FAAS. Dispersive liquid-liquid microextraction is a modified solvent extraction method and its acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the proposed approach, 1,5-diphenyl carbazide (DPC was used as a copper ion selective complexing agent. Several variables such as the extraction and dispersive solvent type and volume, pH of sample solution, DPC concentration, extraction time, and ionic strength were studied and optimized for a quantitative preconcentration and determination of copper (II and at the optimized conditions: 60 μL, 0.5 mL, and 5 mL of extraction solvent (chloroform, disperser solvent (ethanol, and sample volume, respectively, a linear calibration graph was obtained over the concentration range of 10–200 μg L−1 for Cu (II with R2 = 0.9966. The limit of detection (3Sb/m, and preconcentration factor are 2 μg L−1 and 25, respectively. The relative standard deviation (n=10 at 100 μg L−1 of Cu (II is 2.5%. The applicability of the developed technique was evaluated by application to spiked environmental water samples.

  4. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid-liquid microextraction coupled with flame atomic absorption spectrometry.

    Science.gov (United States)

    Anthemidis, Aristidis N; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D

    2012-07-06

    A simple and fast preconcentration/separation dispersive liquid-liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L(-1) and 3.3% for lead and 0.12 μg L(-1) and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Dispersive liquid-liquid microextraction for the determination of copper in cereals and vegetable food samples using flame atomic absorption spectrometry.

    Science.gov (United States)

    Shrivas, Kamlesh; Jaiswal, Nitin Kumar

    2013-12-01

    Dispersive liquid-liquid microextraction (DLLME) is applied for the determination of copper in cereals and vegetable food samples using flame atomic absorption spectrometry (FAAS). The maximum extraction efficiency of copper was obtained after the optimisation of parameters such as extraction and dispersing solvents, pH, concentration of 2,9-dimethyl-1,10-phenanothroline (DPT), N-phenylbenzimidoyl thiourea (PBITU) and salt. The optimised methodology exhibited a good linearity in the range of 0.2-20 ng/mL copper with relative standard deviations percentage (RSD,%) from ±1.5% to 3.5%. The method is found to be simple and rapid for the analysis of copper in food samples with the limit of detection (LOD) and quantitation (LOQ) were 0.05 and 0.16 ng/mL, respectively. Good recoveries of copper were obtained in the range of 93.5-98.0% in food samples as well as in Certified Reference Material (99.1%). The application of the proposed method has been successfully tested for the determination of copper in cereals (maize, millet, rice, wheat, gram, lentils, kidney beans and green beans) and vegetable (potato, cauliflower, tomato, spinach, green beans, lettuce, egg plants and bitter gourd) food samples. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L.; Gil, F.

    2010-01-01

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  7. Feasibility of using in situ fusion for the determination of Co, Cr and Mn in Portland cement by direct solid sampling graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Intima, Danielle Polidorio; de Oliveira, Elisabeth; Oliveira, Pedro Vitoriano

    2009-01-01

    In situ fusion on the boat-type graphite platform has been used as a sample pretreatment for the direct determination of Co, Cr and Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS). The 3-field Zeeman technique was adopted for background correction to decrease the sensitivity during measurements. This strategy allowed working with up to 200 μg of sample. The in situ fusion was accomplished using 10 μL of a flux mixture 4.0% m/v Na 2 CO 3 + 4.0% m/v ZnO + 0.1% m/v Triton (registered) X-100 added over the cement sample and heated at 800 deg. C for 20 s. The resulting mould was completely dissolved with 10 μL of 0.1% m/v HNO 3 . Limits of detection were 0.11 μg g - 1 for Co, 1.1 μg g - 1 for Cr and 1.9 μg g - 1 for Mn. The accuracy of the proposed method has been evaluated by the analysis of certified reference materials. The values found presented no statistically significant differences compared to the certified values (Student's t-test, p < 0.05). In general, the relative standard deviation was lower than 12% (n = 5).

  8. Determination of ultra-trace amounts of prosthesis-related metals in whole blood using volumetric absorptive micro-sampling and tandem ICP - Mass spectrometry.

    Science.gov (United States)

    Bolea-Fernandez, Eduardo; Phan, Kim; Balcaen, Lieve; Resano, Martín; Vanhaecke, Frank

    2016-10-19

    This paper reports on an evaluation of the suitability of a novel sample collection approach, volumetric absorptive micro-sampling (VAMS), in the context of the determination of ultra-trace concentrations of prosthesis-related metals (Al, Ti, V, Co, Cr, Ni, Sr and Zr) in whole blood. In a first phase, a simple dilute-and-shoot approach (100-fold dilution) followed by tandem ICP - mass spectrometry (ICP-MS/MS) analysis was developed for the accurate and sensitive determination of the target elements. The ICP-MS/MS method relies on the use of mass shift reactions proceeding when pressurizing the collision/reaction cell (CRC) with CH 3 F/He for dealing with spectral overlap. Limits of detection (LoDs) between 0.3 and 30 ng L -1 were attained in a multi-element approach. The accuracy of the method was demonstrated via successful analysis of the reference materials Seronorm Whole Blood Levels 1 and 3, and real venous blood samples, spiked with the target elements at different concentration levels (5-50 μg L -1 ). Although the implementation of VAMS devices introduced contamination problems for Al, Cr and Ni, VAMS followed by ICP-MS/MS analysis shows potential for future real-life routine applications when assessing levels of Ti, V, Co, Sr and/or Zr. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: determination of copper and lead by flame atomic absorption spectrometry in water samples.

    Science.gov (United States)

    Anthemidis, Aristidis N; Ioannou, Kallirroy-Ioanna G

    2006-08-04

    Polychlorotrifluoroethylene (PCTFE) in the form of beads was applied, as packing material for flow injection on-line column preconcentration and separation systems coupled with flame atomic absorption spectrometry (FAAS). Its performance characteristics were evaluated for trace copper determination in environmental samples. The on-line formed complex of metal with diethyldithiophosphate (DDPA) was sorbed on the PCTFE surface. Isobutyl methyl ketone (IBMK) at a flow rate of 2.8 mL min(-1) was used to elute the analyte complex directly into the nebulizer-burner system of spectrophotometer. The proposed sorbent material reveal, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates up to 15 mL min(-1) without loss of retention efficiency. For copper determination, with 90 s preconcentration time the sample frequency was 30 h(-1), the enhancement factor was 250, which could be further improved by increasing the loading (preconcentration) time. The detection limit (3s) was c(L)=0.07 microg L(-1), and the precision (R.S.D.) was 1.8%, at the 2.0 microg L(-1) Cu(II) level. For lead determination, the detection limit was c(L)=2.7 microg L(-1), and the precision (R.S.D.) 2.2%, at the 40.0 microg L(-1) Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials and by recovery measurements on spiked natural water samples.

  10. A novel preconcentration procedure using cloud point extraction for determination of lead, cobalt and copper in water and food samples using flame atomic absorption spectrometry.

    Science.gov (United States)

    Citak, Demirhan; Tuzen, Mustafa

    2010-05-01

    In this work, a new cloud point extraction (CPE) procedure was developed for the separation and preconcentration of lead(II), cobalt(II), and copper(II) in various water and food samples. Complexes of metal ions with 1-Phenylthiosemicarbazide (1-PTSC) were extracted into the surfactant-rich phase of octylphenoxypolyethoxyethanol (Triton X-114) from samples. After phase separation, the enriched analytes were determined by flame atomic absorption spectrometry (FAAS). Factors affecting cloud point extraction, such as pH, reagent and surfactant concentrations, temperature, and incubation time were evaluated and optimized. The interference effect of some cations and anions was also studied. After optimization of the CPE conditions, the preconcentration factor of 25 and the limits of detection (L.O.D.) obtained for lead(II), cobalt(II), and copper(II) based on three sigma (n=20) were 3.42, 1.00, and 0.67 microg L(-1), respectively. The method presented precision (R.S.D.) between 1.7% and 4.8% (n=7). The presented preconcentration procedure was applied to the determination of metal ions in reference standard materials (SRM 1515 Apple leaves and GBW 07605 Tea) and some real samples including tap water, spring water, sea water, canned fish, black tea, green tea, tomato sauce and honey. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  11. Ancient wood of the Acqualadrone rostrum: materials history through gas chromatography/mass spectrometry and sulfur X-ray absorption spectroscopy.

    Science.gov (United States)

    Frank, Patrick; Caruso, Francesco; Caponetti, Eugenio

    2012-05-15

    In 2008 the rostrum from an ancient warship was recovered from the Mediterranean near Acqualadrone, Sicily. To establish its provenance and condition, samples of black and brown rostrum wood were examined using sulfur K-edge X-ray absorption spectroscopy (XAS) and gas chromatography/mass spectrometry (GC/MS). GC/MS of pyrolytic volatiles yielded only guaiacyl derivatives, indicating construction from pinewood. A derivatized extract of black wood yielded forms of abietic acid and sandaracopimaric acid consistent with pine pitch waterproofing. Numerical fits to the sulfur K-edge XAS spectra showed that about 65% of the endogenous sulfur consisted of thiols and disulfides. Elemental sulfur was about 2% and 7% in black and brown wood, respectively, while pyritic sulfur was about 12% and 6%. About 2% of the sulfur in both wood types was modeled as trimethylsulfonium, possibly reflecting biogenic (dimethylsulfonio)propionate. High-valent sulfur was exclusively represented by sulfate esters, consistent with bacterial sulfotransferase activity. Traces of chloride were detected, but no free sulfate ion. In summary, the rostrum was manufactured of pine wood and subsequently waterproofed with pine pitch. The subsequent 2300 years included battle, foundering, and marine burial followed by anoxia, bacterial colonization, sulfate reduction, and mobilization of transition metals, which produced pyrite and copious appended sulfur functionality.

  12. Determination of mercury and selenium in herbal medicines and hair by using a nanometer TiO2-coated quartz tube atomizer and hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Li, Shun-Xing; Zheng, Feng-Ying; Cai, Shu-Jie; Cai, Tian-Shou

    2011-01-01

    The nanometer TiO 2 particle was coated onto the inner wall of a T-shaped quartz tube atomizer (QTA) and then was used as a new atomizer (NT-QTA) for the determination of Hg and Se by hydride generation atomic absorption spectrometry (HGAAS). After coating 67.4 mg TiO 2 on a quartz tube, the analytical performance of NT-QTA-HGAAS was compared to conventional QTA-HGAAS and it was improved as follows: (a) the linear range of the calibration curves was expanded from 10.0-80.0 ng mL -1 to 5.0-150.0 ng mL -1 for Hg, and from 10.0-70.0 ng mL -1 to 5.0-100.0 ng mL -1 for Se; (b) the characteristic concentration of was decreased from 2.8 ng mL -1 /1% to 1.1 ng mL -1 /1% for Hg and from 1.2 ng mL -1 /1% to 0.8 ng mL -1 /1% for Se; and (c) the interference from the coexistence of As on the determination of Hg and Se could be eliminated. The achieved technique was applied for the determination of Hg and Se in herbal medicines and hair.

  13. Preparation of modified magnetic nanoparticles as a sorbent for the preconcentration and determination of cadmium ions in food and environmental water samples prior to flame atomic absorption spectrometry

    Science.gov (United States)

    Mirabi, Ali; Dalirandeh, Zeinab; Rad, Ali Shokuhi

    2015-05-01

    A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe3O4 as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L-1 HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml-1 and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results.

  14. Indirect determination of the flavor enhancer maltol in foods and beverages through flame atomic absorption spectrometry after ultrasound assisted-cloud point extraction.

    Science.gov (United States)

    Altunay, Nail; Gürkan, Ramazan; Orhan, Ulaş

    2017-11-15

    A simple ultrasound assisted-cloud point extraction (UA-CPE) method was developed and combined with flame atomic absorption spectrometry (FAAS) for pre-concentration and indirect determination of the flavor enhancer maltol in foods and beverages. The method is based on reduction of Cu(II) to Cu(I) by maltol at pH 6.5, and subsequent selective interaction of Cu(I) with bathocuproine (BCP) to form a ternary complex in presence of sodium dodecyl sulfate (SDS). Under the optimized conditions, pre-concentration of a 35mL sample solution allowed detection of 1.24µgL -1 maltol in a linear range of 4-230µgL -1 . The method was validated by intra- and inter-day precision studies ranging from 2.1 to 3.4%, and recoveries ranged from 93.3% to 104.4% using standard addition method. After pretreatment with two different sample preparation steps assisted by ultrasound energy, the proposed method was applied successfully for determination of maltol in selected foods and beverages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Real-time monitoring of respiratory absorption factors of volatile organic compounds in ambient air by proton transfer reaction time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhonghui [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Yanli [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Center for Excellence in Urban Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Yan, Qiong [Department of Respiratory Diseases, Guangzhou No. 12 People' s Hospital, Guangzhou 510620 (China); Zhang, Zhou [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Wang, Xinming, E-mail: wangxm@gig.ac.cn [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Center for Excellence in Urban Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China)

    2016-12-15

    Respiratory absorption factors (AFs) are essential parameters in the evaluation of human health risks from toxic volatile organic compounds (VOCs) in ambient air. A method for the real time monitoring of VOCs in inhaled and exhaled air by proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) has been developed to permit the calculation of respiratory AFs of VOCs. Isoprene was found to be a better breath tracer than O{sub 2}, CO{sub 2}, humidity, or acetone for distinguishing between the expiratory and inspiratory phases, and a homemade online breath sampling device with a buffer tube was used to optimize signal peak shapes. Preliminary tests with seven subjects exposed to aromatic hydrocarbons in an indoor environment revealed mean respiratory AFs of 55.0%, 55.9%, and 66.9% for benzene, toluene, and C8-aromatics (ethylbenzene and xylenes), respectively. These AFs were lower than the values of 90% or 100% used in previous studies when assessing the health risks of inhalation exposure to hazardous VOCs. The mean respiratory AFs of benzene, toluene and C8-aromatics were 66.5%, 70.2% and 82.3% for the three female subjects; they were noticeably much higher than that of 46.4%, 45.2% and 55.3%, respectively, for the four male subjects.

  16. Selenium analysis by an integrated microwave digestion-needle trap device with hydride sorption on carbon nanotubes and electrothermal atomic absorption spectrometry determination

    Science.gov (United States)

    Maratta Martínez, Ariel; Vázquez, Sandra; Lara, Rodolfo; Martínez, Luis Dante; Pacheco, Pablo

    2018-02-01

    An integrated microwave assisted digestion (MW-AD) - needle trap device (NTD) for selenium determination in grape pomace samples is presented. The NTD was filled with oxidized multiwall carbon nanotubes (oxMWCNTS) where Se hydrides were preconcentrated. Determination was carried out by flow injection-electrothermal atomic absorption spectrometry (FI-ETAAS). The variables affecting the system were established by a multivariate design (Plackett Burman), indicating that the following variables significantly affect the system: sample amount, HNO3 digestion solution concentration, NaBH4 volume and elution volume. A Box-Behnken design was implemented to determine the optimized values of these variables. The system improved Se atomization in the graphite furnace, since only trapped hydrides reached the graphite furnace, and the pyrolysis stage was eliminated according to the aqueous matrix of the eluate. Under optimized conditions the system reached a limit of quantification of 0.11 μg kg- 1, a detection limit of 0.032 μg kg- 1, a relative standard deviation of 4% and a preconcentration factor (PF) of 100, reaching a throughput sample of 5 samples per hour. Sample analysis show Se concentrations between 0.34 ± 0.03 μg kg- 1 to 0.48 ± 0.03 μg kg- 1 in grape pomace. This system provides minimal reagents and sample consumption, eliminates discontinuous stages between samples processing reaching a simpler and faster Se analysis.

  17. Cloud point extraction for the determination of lead and cadmium in urine by graphite furnace atomic absorption spectrometry with multivariate optimization using Box-Behnken design

    International Nuclear Information System (INIS)

    Maranhao, Tatiane de A; Martendal, Edmar; Borges, Daniel L.G.; Carasek, Eduardo; Welz, Bernhard; Curtius, Adilson J.

    2007-01-01

    Cloud point extraction (CPE) is proposed as a pre-concentration procedure for the determination of Pb and Cd in undigested urine by graphite furnace atomic absorption spectrometry (GF AAS). Aliquots of 0.5 mL urine were acidified with HCl and the chelating agent ammonium O,O-diethyl dithiophosphate (DDTP) was added along with the non-ionic surfactant Triton X-114 at the optimized concentrations. Phase separation was achieved by heating the mixture to 50 deg. C for 15 min. The surfactant-rich phase was analyzed by GF AAS, employing the optimized pyrolysis temperatures of 900 deg. C for Pb and 800 deg. C for Cd, using a graphite tube with a platform treated with 500 μg Ru as permanent modifier. The reagent concentrations for CPE (HCl, DDTP and Triton X-114) were optimized using a Box-Behnken design. The response surfaces and the optimum values were very similar for aqueous solutions and for the urine samples, demonstrating that aqueous standards submitted to CPE could be used for calibration. Detection limits of 40 and 2 ng L -1 for Pb and Cd, respectively, were obtained along with an enhancement factor of 16 for both analytes. Three control urine samples were analyzed using this approach, and good agreement was obtained at a 95% statistical confidence level between the certified and determined values. Five real samples have also been analyzed before and after spiking with Pb and Cd, resulting in recoveries ranging from 97 to 118%

  18. Application of l-cystine modified zeolite for preconcentration and determination of ultra-trace levels of cadmium by flame atomic absorption spectrometry.

    Science.gov (United States)

    Rezvani, Seyyed Ahmad; Soleymanpour, Ahmad

    2016-03-04

    A very convenient, sensitive and precise solid phase extraction (SPE) system was developed for enrichment and determination of ultra-trace of cadmium ion in water and plant samples. This method was based on the retention of cadmium(II) ions by l-cystine adsorbed in Y-zeolite and carry out in a packed mini-column. The retained cadmium ions then were eluted and determined by flame atomic absorption spectrometry. The scanning electron microscopy (SEM), powder X-ray diffraction (XRD) and Fourier Transform Infrared (FT-IR) spectroscopy techniques were applied for the characterization of cystine modified zeolite (CMZ). Some experimental conditions affecting the analytical performance such as pH, eluent type, concentration of sample, eluent flow rate and also the presence of interfering ions were investigated. The calibration graph was linear within the range of 0.1-7.5ngmL(-1) and limit of detection was obtained 0.04ngmL(-1) with the preconcentration factor of 400. The relative standard deviation (RSD) was obtained 1.4%, indicating the excellent reproducibility of this method. The proposed method was successfully applied for the extraction and determination of cadmium(II) ion in black tea, cigarette's tobacco and also various water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Direct extraction of lead (II) from untreated human blood serum using restricted access carbon nanotubes and its determination by atomic absorption spectrometry.

    Science.gov (United States)

    Barbosa, Valéria Maria Pereira; Barbosa, Adriano Francisco; Bettini, Jefferson; Luccas, Pedro Orival; Figueiredo, Eduardo Costa

    2016-01-15

    Oxidized carbon nanotubes were covered with layers of bovine serum albumin to result in so-called restricted-access carbon nanotubes (RACNTs). This material can extract Pb(2+) ions directly from untreated human blood serum while excluding all the serum proteins. The RACNTs have a protein exclusion capacity of almost 100% and a maximum Pb(2+) adsorption capacity of 34.5mg g(-1). High resolution transmission electron microscopy, scanning transmission electron microscopy and energy dispersive spectroscopy were used to confirm the BSA layer and Pb(2+) adsorption sites. A mini-column filled with RACNTs was used in an on-line solid phase extraction system coupled to a thermospray flame furnace atomic absorption spectrometry. At optimized experimental conditions, the method has a detection limit as low as 2.1µg L(-1), an enrichment factor of 5.5, and inter- and intra-day precisions (expressed as relative standard deviation) of <8.1%. Recoveries of the Pb(2+) spiked samples ranged from 89.4% to 107.3% for the extraction from untreated human blood serum. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. A new cloud point extraction procedure for determination of inorganic antimony species in beverages and biological samples by flame atomic absorption spectrometry.

    Science.gov (United States)

    Altunay, Nail; Gürkan, Ramazan

    2015-05-15

    A new cloud-point extraction (CPE) for the determination of antimony species in biological and beverages samples has been established with flame atomic absorption spectrometry (FAAS). The method is based on the fact that formation of the competitive ion-pairing complex of Sb(III) and Sb(V) with Victoria Pure Blue BO (VPB(+)) at pH 10. The antimony species were individually detected by FAAS. Under the optimized conditions, the calibration range for Sb(V) is 1-250 μg L(-1) with a detection limit of 0.25 μg L(-1) and sensitive enhancement factor of 76.3 while the calibration range for Sb(III) is 10-400 μg L(-1) with a detection limit of 5.15 μg L(-1) and sensitive enhancement factor of 48.3. The precision as a relative standard deviation is in range of 0.24-2.35%. The method was successfully applied to the speciative determination of antimony species in the samples. The validation was verified by analysis of certified reference materials (CRMs). Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. A Green Preconcentration Method for Determination of Cobalt and Lead in Fresh Surface and Waste Water Samples Prior to Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Naeemullah

    2012-01-01

    Full Text Available Cloud point extraction (CPE has been used for the preconcentration and simultaneous determination of cobalt (Co and lead (Pb in fresh and wastewater samples. The extraction of analytes from aqueous samples was performed in the presence of 8-hydroxyquinoline (oxine as a chelating agent and Triton X-114 as a nonionic surfactant. Experiments were conducted to assess the effect of different chemical variables such as pH, amounts of reagents (oxine and Triton X-114, temperature, incubation time, and sample volume. After phase separation, based on the cloud point, the surfactant-rich phase was diluted with acidic ethanol prior to its analysis by the flame atomic absorption spectrometry (FAAS. The enhancement factors 70 and 50 with detection limits of 0.26 μg L−1 and 0.44 μg L−1 were obtained for Co and Pb, respectively. In order to validate the developed method, a certified reference material (SRM 1643e was analyzed and the determined values obtained were in a good agreement with the certified values. The proposed method was applied successfully to the determination of Co and Pb in a fresh surface and waste water sample.

  2. An automated flow injection system for metal determination by flame atomic absorption spectrometry involving on-line fabric disk sorptive extraction technique.

    Science.gov (United States)

    Anthemidis, A; Kazantzi, V; Samanidou, V; Kabir, A; Furton, K G

    2016-08-15

    A novel flow injection-fabric disk sorptive extraction (FI-FDSE) system was developed for automated determination of trace metals. The platform was based on a minicolumn packed with sol-gel coated fabric media in the form of disks, incorporated into an on-line solid-phase extraction system, coupled with flame atomic absorption spectrometry (FAAS). This configuration provides minor backpressure, resulting in high loading flow rates and shorter analytical cycles. The potentials of this technique were demonstrated for trace lead and cadmium determination in environmental water samples. The applicability of different sol-gel coated FPSE media was investigated. The on-line formed complex of metal with ammonium pyrrolidine dithiocarbamate (APDC) was retained onto the fabric surface and methyl isobutyl ketone (MIBK) was used to elute the analytes prior to atomization. For 90s preconcentration time, enrichment factors of 140 and 38 and detection limits (3σ) of 1.8 and 0.4μgL(-1) were achieved for lead and cadmium determination, respectively, with a sampling frequency of 30h(-1). The accuracy of the proposed method was estimated by analyzing standard reference materials and spiked water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Pereira, Éderson R; de Almeida, Tarcísio S; Borges, Daniel L G; Carasek, Eduardo; Welz, Bernhard; Feldmann, Jörg; Campo Menoyo, Javier Del

    2016-04-01

    High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) has been applied for the development of a method for the determination of total As in fish oil samples using direct analysis. The method does not use any sample pretreatment, besides dilution with 1-propanole, in order to decrease the oil viscosity. The stability and sensitivity of As were evaluated using ruthenium and iridium as permanent chemical modifiers and palladium added in solution over the sample. The best results were obtained with ruthenium as the permanent modifier and palladium in solution added to samples and standard solutions. Under these conditions, aqueous standard solutions could be used for calibration for the fish oil samples diluted with 1-propanole. The pyrolysis and atomization temperatures were 1400 °C and 2300 °C, respectively, and the limit of detection and characteristic mass were 30 pg and 43 pg, respectively. Accuracy and precision of the method have been evaluated using microwave-assisted acid digestion of the samples with subsequent determination by HR-CS GF AAS and ICP-MS; the results were in agreement (95% confidence level) with those of the proposed method. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Synthesize of silver-nanoparticles by plant extract and its application for preconcentration of cadmium followed by flame atomic absorption spectrometry.

    Science.gov (United States)

    Almertaha, Abdul-Hossein; Eftekhari, Mohammad; Chamsaz, Mahmoud; Gheibi, Mohammad

    2018-02-02

    In this paper, Mentha pulegium leaves extract was used as a green reducing agent for the synthesis of silver-nanoparticles. The synthesized silver-nanoparticles were characterized by UV-VIS spectrophotometry, transmission electron microscopy, X-ray spectroscopy and used as an adsorbent for preconcentration of trace levels of cadmium (ІІ). After the desorption of cadmium (ІІ) in 5 mol L -1 formic acid, the desorbent solution was aspirated into the flame atomic absorption spectrometry for the determination of cadmium. In order to optimize the experimental condition, a response surface methodology based on central composite design was used. The optimum conditions are: pH: 8.6, amounts of adsorbent: 30 mg, 10 min extraction time and desorption time of 2 min. Under the optimum condition, the calibration curve was linear in the range of 5-200 μg L -1 cadmium (ІІ) ion with a correlation coefficient of 0.9995. The limit of detection was 1.1 μg L -1 and the relative standard deviation for 25 μg L -1 cadmium (ІІ) ion was 3.0% (n = 5). In order to check the applicability of the proposed method, different real samples were analyzed. Also, the accuracy of this method was successfully checked by the analysis of certified reference material and spike tests.

  5. A dispersive liquid--liquid microextraction methodology for copper (II) in environmental samples prior to determination using microsample injection flame atomic absorption spectrometry.

    Science.gov (United States)

    Alothman, Zeid A; Habila, Mohamed; Yilmaz, Erkan; Soylak, Mustafa

    2013-01-01

    A simple, environmentally friendly, and efficient dispersive liquid-liquid microextraction method combined with microsample injection flame atomic absorption spectrometry was developed for the separation and preconcentration of Cu(II). 2-(5-Bromo-2-pyridylazo)-5-(diethylamino)phenol (5-Br-PADAP) was used to form a hydrophobic complex of Cu(II) ions in the aqueous phase before extraction. To extract the Cu(II)-5-Br-PADAP complex from the aqueous phase to the organic phase, 2.0 mL of acetone as a disperser solvent and 200 microL of chloroform as an extraction solvent were used. The influences of important analytical parameters, such as the pH, types and volumes of the extraction and disperser solvents, amount of chelating agent, sample volume, and matrix effects, on the microextraction procedure were evaluated and optimized. Using the optimal conditions, the LOD, LOQ, preconcentration factor, and RSD were determined to be 1.4 microg/L, 4.7 microg/L, 120, and 6.5%, respectively. The accuracy of the proposed method was investigated using standard addition/recovery tests. The analysis of certified reference materials produced satisfactory analytical results. The developed method was applied for the determination of Cu in real samples.

  6. One-step displacement dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of methylmercury in environmental samples.

    Science.gov (United States)

    Liang, Pei; Kang, Caiyan; Mo, Yajun

    2016-01-01

    A novel method for the selective determination of methylmercury (MeHg) was developed by one-step displacement dispersive liquid-liquid microextraction (D-DLLME) coupled with graphite furnace atomic absorption spectrometry. In the proposed method, Cu(II) reacted with diethyldithiocarbamate (DDTC) to form Cu-DDTC complex, which was used as the chelating agent instead of DDTC for the dispersive liquid-liquid microextraction (DLLME) of MeHg. Because the stability of MeHg-DDTC is higher than that of Cu-DDTC, MeHg can displace Cu from the Cu-DDTC complex and be preconcentrated in a single DLLME procedure. MeHg could be extracted into the extraction solvent phase at pH 6 while Hg(II) remained in the sample solution. Potential interference from co-existing metal ions with lower DDTC complex stability was largely eliminated without the need of any masking reagent. Under the optimal conditions, the limit of detection of this method was 13.6ngL(-1) (as Hg), and an enhancement factor of 81 was achieved with a sample volume of 5.0mL. The proposed method was successfully applied for the determination of trace MeHg in some environmental samples with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometry.

    Science.gov (United States)

    Martinis, Estefanía M; Bertón, Paula; Olsina, Roberto A; Altamirano, Jorgelina C; Wuilloud, Rodolfo G

    2009-08-15

    A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)mim][PF(6)]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 microl of 9.0 mol L(-1) hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3ngL(-1) and the relative standard deviation (RSD) for 10 replicates at 1 microg L(-1) Hg(2+) was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).

  8. Trace mercury determination in drinking and natural water after preconcentration and separation by DLLME-SFO method coupled with cold vapor atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Abdollahi Atousa

    2014-07-01

    Full Text Available A novel dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO for simultaneous separation/preconcentration of ultra trace amounts of mercury was used. A method based on amalgamation was used for collection of gaseous mercury on gold coated sand (Gold trap. The concentration of mercury was determined by cold vapor atomic absorption spectrometry (CV-AAS. The DLLME-SFO behavior of mercury by using dithizone as complexing agent was systematically investigated. The factors influencing, the complex formation and extraction of DLLME-SFO method such as type and volume of extraction and disperser solvents, pH, concentration of salt, centrifuging time and concentration of the chelating agent were optimized. The method was successfully applied to the determination of mercury in drinking and natural water and satisfactory relative recoveries (95–105% were achieved. The proposed procedure was based on very low consumption of organic solvents. The other benefits of the system were sensitive, simple, friendly to the environment, rejection of matrix constituent, low cost, the time consuming and high enrichment factor.

  9. Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Martinis, Estefania M.; Berton, Paula; Olsina, Roberto A.; Altamirano, Jorgelina C.; Wuilloud, Rodolfo G.

    2009-01-01

    A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C 4 mim][PF 6 ]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 μl of 9.0 mol L -1 hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3 ng L -1 and the relative standard deviation (RSD) for 10 replicates at 1 μg L -1 Hg 2+ was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).

  10. [Determination of trace lead and cadmium in transgenic rice by crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration combined with graphite furnace atomic absorption spectrometry].

    Science.gov (United States)

    Liu, Hua-qing; Li, Sheng-qing; Qu, Yang; Chen, Hao

    2012-02-01

    A novel method was developed for the determination of trace lead and cadmium in transgenic brown rice based on separation and preconcentration with a micro column packed with crosslinked carboxymethyl konjac glucomannan (CCMKGM) prior to its determination by graphite furnace atomic absorption spectrometry. Variables affecting the separation and preconcentration of lead and cadmium, such as the acidity of the aqueous solution, sample flow rate and volume, and eluent concentration and volume, were optimized. Under optimized condition, detection limits of the method for the determination of trace lead and cadmium in transgenic brown rice were 0.11 and 0.002 microg x L(-1), respectively. The obtained results of lead and cadmium in the certified reference material (GBW10010, GBS1-1) were in good agreement with the certified values. The recoveries were in the range of 90%-103% and 93%-105% for detection of Pb and Cd in transgenic brown rice and the wild-type brown rice samples respectively. This study could provide technical support for determination of trace Pb and Cd in transgenic rice.

  11. Preconcentration, speciation and determination of ultra trace amounts of mercury by modified octadecyl silica membrane disk/electron beam irradiation and cold vapor atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ashkenani, Hamid [Department of Chemistry, Yazd University, Yazd (Iran, Islamic Republic of); Dadfarnia, Shayessteh [Department of Chemistry, Yazd University, Yazd (Iran, Islamic Republic of)], E-mail: sdadfarnia@yazduni.ac.ir; Shabani, Ali Mohammad Haji; Jaffari, Abbas Ali [Department of Chemistry, Yazd University, Yazd (Iran, Islamic Republic of); Behjat, Abbas [Department of physics, Yazd University, Yazd (Iran, Islamic Republic of)

    2009-01-15

    Mercury (II) and methyl mercury cations at the Sub-ppb level were adsorbed quantitatively from aqueous solution onto an octadecyl-bonded silica membrane disk modified by 2-[(2-mercaptophyenylimino)methyl] phenol (MPMP). The trapped mercury was then eluted with 3 ml ethanol and Hg{sup 2+} ion was directly measured by cold vapor atomic absorption spectrometry, utilizing tin (II) chloride. Total mercury (Hgt) was determined after conversion of MeHg{sup +} into Hg{sup 2+} ion by electron beam irradiation. A sample volume of 1500 ml resulted in a preconcentration factor of 500 and the precision for a sampling volume of 500 ml at a concentration of 2.5 {mu}g l{sup -1} (n = 7) was 3.1%. The limit of detection of the proposed method is 3.8 ng l{sup -1}. The method was successfully applied to analysis of water samples, and the accuracy was assessed via recovery experiment.

  12. Determination of cadmium and lead in mussels by electrothermal atomic absorption spectrometry using an ultrasound-assisted extraction method optimized by factorial design

    Energy Technology Data Exchange (ETDEWEB)

    Lavilla, I.; Capelo, J.L.; Bendicho, C. [Departamento de Quimica Analitica y Alimentaria, Universidad de Vigo, Facultad de Ciencias (Quimicas), As Lagoas - Marcosende s/n. E-36200 Vigo (Spain)

    1999-02-01

    A simple and rapid method is described for the quantitative extraction and determination of Cd and Pb in mussel tissue (Mytilus edulis). The method is based on the quantitative ultrasound-assisted extraction (i.e. sample mass at mg level) of the two metals using diluted nitric acid as extractant. The extraction procedure is carried out in autosampler cups of the graphite furnace (typically, less than 20 mg). A two-level full factorial design (2{sup 4}) was applied to optimize the variables influencing the ultrasound extraction process. These variables were: extraction time, ultrasound amplitude, nitric acid concentration and particle size. Optimization results showed that acid concentration and particle size were the more significant variables. Determination of Cd and Pb in extracts obtained after ultrasound treatment was carried out by Electrothermal Atomic Absorption Spectrometry. The method was validated by statistically comparing the metal contents found with the certified ones corresponding to the BCR 278 mussel tissue. No significant differences were observed for P= 0.05. LODs for Cd and Pb in mussel tissue were 0.019 and 0.37 {mu}g g{sup -1}. RSDs values (corresponding to between-batch precision for n= 5) were 2.2 and 6.7% for Cd and Pb, respectively. The method was applied to measure the contents of Cd and Pb in mussels used as pollution bioindicators from the Galician coast (Ria de Vigo, Spain). (orig.) With 2 figs., 9 tabs., 6 refs.

  13. Speciation and determination of inorganic mercury and methylmercury by headspace single drop microextraction and electrothermal atomic absorption spectrometry in water and fish

    Energy Technology Data Exchange (ETDEWEB)

    Sarica, Deniz Yurtsever [Scientific and Technological Research Council of Turkey, Ankara Test and Analysis Laboratory, TUeBITAK/ATAL, Besevler, Ankara (Turkey); Tuerker, Ali Rehber [Science Faculty, Department of Chemistry, Gazi University, Ankara (Turkey)

    2012-05-15

    In this study, headspace single drop microextraction (HS-SDME) method in combination with electrothermal atomic absorption spectrometry (ETAAS) method was developed and validated for the speciation and determination of inorganic mercury (iHg) and methylmercury (MeHg). MeHg and iHg species were reduced to volatile methylmercury hydride (CH{sub 3}HgH) and elemental mercury, respectively, in the presence of NaBH{sub 4} and trapped onto a drop of acceptor phase in the tip of a microsyringe. Thiourea and ammonium pyrrolydinedithiocarbamate (APDC) were tested as the acceptor phase. The experimental parameters of the method such as microextraction time, temperature, NaBH{sub 4} concentration, acceptor phase concentration, and pH of the medium were investigated to obtain distinctive conditions for mercury species. Possible interference effects have also been investigated. In order to validation of the method, analytical figures of merits such as accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), and linear working range have been evaluated. Accuracy of the method has been verified by analyzing certified reference materials (BCR 453 Tuna fish) and spiked samples. The proposed method was applied for the speciation and determination of mercury species in water and fish samples. Mercury species (MeHg and iHg) have been determined in the real samples with a relative error less than 10%. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. In situ flow cell for combined X-ray absorption spectroscopy, X-ray diffraction, and mass spectrometry at high photon energies under solar thermochemical looping conditions

    Science.gov (United States)

    Rothensteiner, Matthäus; Jenni, Joel; Emerich, Hermann; Bonk, Alexander; Vogt, Ulrich F.; van Bokhoven, Jeroen A.

    2017-08-01

    An in situ/operando flow cell for transmission mode X-ray absorption spectroscopy (XAS), X-ray diffraction (XRD), and combined XAS/XRD measurements in a single experiment under the extreme conditions of two-step solar thermochemical looping for the dissociation of water and/or carbon dioxide was developed. The apparatus exposes materials to relevant conditions of both the auto-reduction and the oxidation sub-steps of the thermochemical cycle at ambient temperature up to 1773 K and enables determination of the composition of the effluent gases by online quadrupole mass spectrometry. The cell is based on a tube-in-tube design and is heated by means of a focusing infrared furnace. It was tested successfully for carbon dioxide splitting. In combined XAS/XRD experiments with an unfocused beam, XAS measurements were performed at the Ce K edge (40.4 keV) and XRD measurements at 64.8 keV and 55.9 keV. Furthermore, XRD measurements with a focused beam at 41.5 keV were carried out. Equimolar ceria-hafnia was auto-reduced in a flow of argon and chemically reduced in a flow of hydrogen/helium. Under reducing conditions, all cerium(iv) was converted to cerium(iii) and a cation-ordered pyrochlore-type structure was formed, which was not stable upon oxidation in a flow of carbon dioxide.

  15. Application of high-resolution continuum source flame atomic absorption spectrometry to reveal, evaluate and overcome certain spectral effects in Pb determination of unleaded gasoline

    Science.gov (United States)

    Kowalewska, Zofia; Laskowska, Hanna; Gzylewski, Michał

    2017-06-01

    High-resolution continuum source and line source flame atomic absorption spectrometry (HR-CS FAAS and LS FAAS, respectively) were applied for Pb determination in unleaded aviation or automotive gasoline that was dissolved in methyl-isobutyl ketone. When using HR-CS FAAS, a structured background (BG) was registered in the vicinity of both the 217.001 nm and 283.306 nm Pb lines. In the first case, the BG, which could be attributed to absorption by the OH molecule, directly overlaps with the 217 nm line, but it is of relatively low intensity. For the 283 nm line, the structured BG occurs due to uncompensated absorption by OH molecules present in the flame. BG lines of relatively high intensity are situated at a large distance from the 283 nm line, which enables accurate analysis, not only when using simple variants of HR-CS FAAS but also for LS FAAS with a bandpass of 0.1 nm. The lines of the structured spectrum at 283 nm can have ;absorption; (maxima) or ;emission; (minima) character. The intensity of the OH spectra can significantly depend on the flame character and composition of the investigated organic solution. The best detection limit for the analytical procedure, which was 0.01 mg L- 1 for Pb in the investigated solution, could be achieved using HR-CS FAAS with the 283 nm Pb line, 5 pixels for the analyte line measurement and iterative background correction (IBC). In this case, least squares background correction (LSBC) is not recommended. However, LSBC (available as the ;permanent structures; option) would be recommended when using the 217 nm Pb line. In LS FAAS, an additional phenomenon related to the nature of the organic matrix (for example, isooctane or toluene) can play an important role. The effect is of continuous character and probably due to the simultaneous efficient correction of the continuous background (IBC) it is not observed in HR-CS FAAS. The fact that the effect does not depend on the flame character indicates that it is not radiation

  16. Oxidation State Specific Generation of Arsines from Methylated Arsenicals Based on L- Cysteine Treatment in Buffered Media for Speciation Analysis by Hydride Generation - Automated Cryotrapping - Gas Chromatography-Atomic Absorption Spectrometry with the Multiatomizer

    OpenAIRE

    Matoušek, Tomáš; Hernández-Zavala, Araceli; Svoboda, Milan; Langrová, Lenka; Adair, Blakely M.; Drobná, Zuzana; Thomas, David J.; Stýblo, Miroslav; Dědina, Jiří

    2008-01-01

    An automated system for hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer is described. Arsines are preconcentrated and separated in a Chromosorb filled U-tube. An automated cryotrapping unit, employing nitrogen gas formed upon heating in the detection phase for the displacement of the cooling liquid nitrogen, has been developed. The conditions for separation of arsines in a Chromosorb filled U-tube have been optimized. A complete se...

  17. Determination of trace amounts of selenium in minerals and rocks by flame less atomic-absorption spectrometry; Determinacion de selinio en minerales y rocas por espectrometria de absorcion atomica

    Energy Technology Data Exchange (ETDEWEB)

    Alduan, F. A.; Capdevilla, C.

    1980-07-01

    The determination of trace amounts of selenium In silicate rocks and feldspar by solvent extraction and graphite furnace atomic-absorption spectrometry has been stu- died. Sodium diethyl-ditio carbamate and ammonium pyrrolidine dithiocarbamate have been tried as chelating agents. The best results are achieved when selenium is extracted Into carbon tetrachloride as the sodium diethyldithiocarbamate complex. The method allows to detect 0,75 ppm of selenium in the sample. Recoveries are about 100%. (Author) 7 refs.

  18. Determination of fluorine in copper concentrate via high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis - Comparison of three target molecules.

    Science.gov (United States)

    Cadorim, Heloisa R; de Gois, Jefferson S; Borges, Aline R; Vale, Maria Goreti R; Welz, Bernhard; Gleisner, Heike; Ott, Christina

    2018-01-01

    The chemical composition of complex inorganic materials, such as copper concentrate, may influence the economics of their further processing because most smelters, and particularly the producers of high-purity electrolyte copper, have strict limitations for the permissible concentration of impurities. These components might be harmful to the quality of the products, impair the production process and be hazardous to the environment. The goal of the present work is the development of a method for the determination of fluorine in copper concentrate using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis. The molecular absorption of the diatomic molecule CaF was measured at 606.440nm. The molecule CaF was generated by the addition of 200µg Ca as the molecule-forming reagent; the optimized pyrolysis and vaporization temperatures were 900°C and 2400°C, respectively. The characteristic mass and limit of detection were 0.5ng and 3ng, respectively. Calibration curves were established using aqueous standard solutions containing the major components Cu, Fe, S and the minor component Ag in optimized concentrations. The accuracy of the method was verified using certified reference materials. Fourteen copper concentrate samples from Chile and Australia were analyzed to confirm the applicability of the method to real samples; the concentration of fluorine ranged from 34 to 5676mgkg -1 . The samples were also analyzed independently at Analytik Jena by different operators, using the same equipment, but different target molecules, InF and GaF, and different operating conditions; but with a few exceptions, the results agreed quite well. The results obtained at Analytik Jena using the GaF molecule and our results obtained with CaF, with one exception, were also in agreement with the values informed by the supplier of the samples, which were obtained using ion selective electrode potentiometry after alkaline fusion. A comparison will

  19. Validation of an analytical method for the determination of total mercury in urine samples using cold vapor atomic absorption spectrometry (CV-AAS)

    International Nuclear Information System (INIS)

    Guilhen, Sabine Neusatz

    2009-01-01

    Mercury (Hg) is a toxic metal applied to a variety of products and processes, representing a risk to the health of occupationally or accidentally exposed subjects. Dental amalgam is a restorative material composed of metallic mercury, which use has been widely debated in the last decades. Due to the dubiety of the studies concerning dental amalgam, many efforts concerning this issue have been conducted. The Tropical Medicine Foundation (Tocantins, Brazil) has recently initiated a study to evaluate the environmental and occupational levels of exposure to mercury in dentistry attendants at public consulting rooms in the city of Araguaina (TO). In collaboration with this study, the laboratory of analysis at IPEN's Chemistry and Environment Center is undertaking the analysis of mercury levels in exposed subjects' urine samples using cold vapor atomic absorption spectrometry. This analysis requires the definition of a methodology capable of generating reliable results. Such methodology can only be implemented after a rigorous validation procedure. As part of this work, a series of tests were conducted in order to confirm the suitability of the selected methodology and to assert that the laboratory addresses all requirements needed for a successful implementation of the methodology. The following parameters were considered in order to test the method's performance: detection and quantitation limits, selectivity, sensitivity, linearity, accuracy and precision. The assays were carried out with certified reference material, which assures the traceability of the results. Taking into account the estimated parameters, the method can be considered suitable for the afore mentioned purpose. The mercury concentration found for the reference material was of (95,12 +- 11,70)mug.L -1 with a recovery rate of 97%. The method was also applied to 39 urine samples, six of which (15%) showing urinary mercury levels above the normal limit of 10μg.L -1 . The obtained results fall into a

  20. Quality assessment of trace Cd and Pb contaminants in Thai herbal medicines using ultrasound-assisted digestion prior to flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Watsaka Siriangkhawut

    2017-10-01

    Full Text Available A simple, efficient, and reliable ultrasound-assisted digestion (UAD procedure was used for sample preparation prior to quantitative determination of trace Cd and Pb contaminants in herbal medicines using flame atomic absorption spectrometry. The parameters influencing UAD such as the solvent system, sample mass, presonication time, sonication time, and digestion temperature were evaluated. The efficiency of the proposed UAD procedure was evaluated by comparing with conventional acid digestion (CAD procedure. Under the optimum conditions, linear calibration graphs in a range of 2–250 μg/L for Cd, and 50–1000 μg/L for Pb were obtained with detection limits of 0.56 μg/L and 10.7 μg/L for Cd and Pb, respectively. The limit of quantification for Cd and Pb were 1.87 μg/L and 40.3 μg/L, respectively. The repeatability for analysis of 10 μg/L for Cd and 100 μg/L for Pb was 2.3% and 2.6%, respectively. The accuracy of the proposed method was evaluated by rice flour certified reference materials. The proposed method was successfully applied for analysis of trace Cd and Pb in samples of various types of medicinal plant and traditional medicine consumed in Thailand. Most herbal medicine samples were not contaminated with Cd or Pb. The contaminant levels for both metals were still lower than the maximum permissible levels of elements in medicinal plant materials and finished herbal products sets by the Ministry of Public Health of Thailand. The exception was the high level of Cd contamination found in two samples of processed medicinal plants.

  1. Applicability of cloud point extraction for the separation trace amount of lead ion in environmental and biological samples prior to determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Sayed Zia Mohammadi

    2016-09-01

    Full Text Available A sensitive cloud point extraction procedure(CPE for the preconcentration of trace lead prior to its determination by flame atomic absorption spectrometry (FAAS has been developed. The CPE method is based on the complex of Pb(II ion with 1-(2-pyridylazo-2-naphthol (PAN, and then entrapped in the non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PAN and Triton X-114, equilibration temperature and time, were investigated in detail. A preconcentration factor of 30 was obtained for the preconcentration of Pb(II ion with 15.0 mL solution. Under the optimal conditions, the calibration curve was linear in the range of 7.5 ng mL−1–3.5 μg mL−1 of lead with R2 = 0.9998 (n = 10. Detection limit based on three times the standard deviation of the blank (3Sb was 5.27 ng mL−1. Eight replicate determinations of 1.0 μg mL−1 lead gave a mean absorbance of 0.275 with a relative standard deviation of 1.6%. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in biological and water samples with satisfactory results.

  2. Preparation of modified magnetic nanoparticles as a sorbent for the preconcentration and determination of cadmium ions in food and environmental water samples prior to flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mirabi, Ali; Dalirandeh, Zeinab [Department of Chemistry, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of); Rad, Ali Shokuhi, E-mail: a.shokuhi@qaemshahriau.ac.ir [Department of Chemical Engineering, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of)

    2015-05-01

    A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe{sub 3}O{sub 4} as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L{sup −1} HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml{sup −1} and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results. - Highlights: • MNPs method is economical, simple, rapid and sensitive for trace analysis of Cd. • High preconcentration factor was obtained easily through this method. • A detection limit at ng mL{sup −1} level was achieved with 100.0 mL of sample. • This method provides good repeatability and extraction efficiency in a short time.

  3. Determination and Quantification of metals in the shells of Crassostrea virginica after the Deepwater Horizon oil spill utilizing Atomic Absorption Spectrometry.

    Science.gov (United States)

    Roopnarine, D.; Patel, S.; Roopnarine, P.; Giarikos, D.; Anderson, L. C.

    2017-12-01

    The Deepwater Horizon (DWH) oil rig explosion on April 20, 2010 resulted in the release of 685,000 tons of crude oil into the Gulf of Mexico (GOM) over a period of three months. There were obvious immediate effects, but the long-term ramifications are still being studied. The primary constituent of crude oil is hydrocarbons with other organic compounds containing nitrogen, oxygen and sulfur. There are also a number of trace metals with the most abundant frequently being iron, nickel, copper and vanadium. These do not degrade like organic materials. However, the exact composition varies among the production sites. The oil from the DWH rig was classified as light crude which is moderately volatile. Natural oil seeps occur in the environment, but the DWH spill represented an acute impact. Trace amounts of heavy metals are a normal part of the composition of marine organisms, but can be toxic in high concentrations. Bivalved molluscs bioaccumulate heavy metals in their tissues and shells, and are therefore often useful as monitors of environmental pollution. We thus used the Eastern oyster Crassostrea virginica to determine the impact of the spill by measuring the concentrations of metals in the shells utilizing flame emission atomic absorption spectrometry. We focused on the hypothesis that DWH spill exposure resulted in an increase in metal uptake into the shells. Specimens spanned the years 2010 to 2014 and ranged from Grand Isle, LA to Apalachicola Bay, Fl. Vanadium had the greatest concentration in the shells, and along with copper, cadmium, zinc and iron displayed an upward trend of increase from 2010 to 2013, with a decline in 2014. However there was unexpected variability, as the specimens from Apalachicola Bay, Fl had higher levels of vanadium when compared to those from Grand Isle, LA. Ongoing work includes an increase of sample sizes from the same geographic localities and time period.

  4. Use of cetyltrimethylammonium bromide as surfactant for the determination of copper and chromium in gasoline emulsions by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Santos, Denilson S.S. dos; Teixeira, Alete P.; Barbosa, Jose T.P.; Ferreira, Sergio L.C.; Korn, Maria das Gracas A; Teixeira, Leonardo S.G.

    2007-01-01

    In this work, the use of cetyltrimethylammonium bromide as surfactant for the preparation of oil-in-water emulsions for the determination of Cu and Cr in gasoline by electrothermal atomic absorption spectrometry (ET AAS) was evaluated. The surfactant amount was tested in the range of 25 to 300 mg, added to 2 ml of gasoline, and completed to 10 mL with 0.1% (v/v) nitric acid solution. 150 mg of surfactant was found optimum, and a sonication time of 10 min sufficient to form an oil-in-water emulsion that was stable for several hours. The ET AAS temperature program was established based on pyrolysis and atomization curves. The pyrolysis temperatures were set at 700 and 1300 deg. C for Cu and Cr, respectively and the selected atomization temperatures were 2400 and 2500 deg. C. The time and temperature of the drying stage and the atomization time were experimentally tested to provide optimum conditions. The limits of detection were found to be 5 μg L -1 and 1.5 μg L -1 for Cu and Cr, respectively in the original gasoline samples. The relative standard deviation (RSD) ranged from 4 to 9% in oil-in-water emulsions spiked with 5 μg L -1 and 15 μg L -1 of each metal, respectively. Recoveries varied from 90 to 98%. The accuracy of the proposed method was tested by an alternate procedure using complete evaporation of the gasoline sample. The method was adequate for the determination of Cu and Cr in gasoline samples collected from different gas stations in Salvador, BA, Brazil

  5. Green method for ultrasensitive determination of Hg in natural waters by electrothermal-atomic absorption spectrometry following sono-induced cold vapor generation and 'in-atomizer trapping'

    International Nuclear Information System (INIS)

    Gil, Sandra; Lavilla, Isela; Bendicho, Carlos

    2007-01-01

    Sono-induced cold vapor generation (SI-CVG) has been used for the first time in combination with a graphite furnace atomizer for determination of Hg in natural waters by electrothermal-atomic absorption spectrometry after in situ trapping onto a noble metal-pretreated platform (Pd, Pt or Rh) inserted into a graphite tube. The system allows 'in-atomizer trapping' of Hg without the use of conventional reduction reactions based on sodium borohydride or tin chloride in acid medium for cold vapor generation. The sono-induced reaction is accomplished by applying ultrasound irradiation to the sample solution containing Hg(II) in the presence of an organic compound such as formic acid. As this organic acid is partly degraded upon ultrasound irradiation to yield CO, CO 2 , H 2 and H 2 O, the amount of lab wastes is minimized and a green methodology is achieved. For this purpose, experimental variables influencing the generation/trapping process are fully investigated. The limit of detection for a 10 min trapping time and 10 mL sample volume was 0.03 μg L -1 (Integrated absorbance) and the repeatability expressed as relative standard deviation was about 3%. Carbonates and chlorides at 100 mg L -1 level caused a signal depression by 20-30%. The enhanced trapping efficiency observed with the sono-induced cold vapor generation as compared with 'in-atomizer trapping' methods employing chemical vapor generation is discussed. A reaction pathway for SI-CVG is proposed on the basis of the current knowledge for synthesis of noble metal nanoparticles by ultrasound

  6. Multiple response optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry with sample injection as detergent emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Brum, Daniel M.; Lima, Claudio F. [Departamento de Quimica, Universidade Federal de Vicosa, A. Peter Henry Rolfs s/n, Vicosa/MG, 36570-000 (Brazil); Robaina, Nicolle F. [Departamento de Quimica Analitica, Universidade Federal Fluminense, Outeiro de S.J. Batista s/n, Centro, Niteroi/RJ, 24020-141 (Brazil); Fonseca, Teresa Cristina O. [Petrobras, Cenpes/PDEDS/QM, Av. Horacio Macedo 950, Ilha do Fundao, Rio de Janeiro/RJ, 21941-915 (Brazil); Cassella, Ricardo J., E-mail: cassella@vm.uff.br [Departamento de Quimica Analitica, Universidade Federal Fluminense, Outeiro de S.J. Batista s/n, Centro, Niteroi/RJ, 24020-141 (Brazil)

    2011-05-15

    The present paper reports the optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry (GF AAS) employing a strategy based on the injection of the samples as detergent emulsions. The method was optimized in relation to the experimental conditions for the emulsion formation and taking into account that the three analytes (Cu, Fe and Pb) should be measured in the same emulsion. The optimization was performed in a multivariate way by employing a three-variable Doehlert design and a multiple response strategy. For this purpose, the individual responses of the three analytes were combined, yielding a global response that was employed as a dependent variable. The three factors related to the optimization process were: the concentration of HNO{sub 3}, the concentration of the emulsifier agent (Triton X-100 or Triton X-114) in aqueous solution used to emulsify the sample and the volume of solution. At optimum conditions, it was possible to obtain satisfactory results with an emulsion formed by mixing 4 mL of the samples with 1 mL of a 4.7% w/v Triton X-100 solution prepared in 10% v/v HNO{sub 3} medium. The resulting emulsion was stable for 250 min, at least, and provided enough sensitivity to determine the three analytes in the five samples tested. A recovery test was performed to evaluate the accuracy of the optimized procedure and recovery rates, in the range of 88-105%; 94-118% and 95-120%, were verified for Cu, Fe and Pb, respectively.

  7. Determination of Pb (Lead, Cd (Cadmium, Cr (Chromium, Cu (Copper, and Ni (Nickel in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Wen-Si Zhong

    2016-01-01

    Full Text Available The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory analytical precisions (represented by relative standard deviations ranging from 0.6% to 2.5% and recoveries (98.91–101.32%. The lead contents in tea leaves were 0.48–10.57 mg/kg, and 80% of these values were below the maximum values stated by the guidelines in China. The contents of cadmium and chromium ranged from 0.01 mg/kg to 0.39 mg/kg and from 0.27 mg/kg to 2.45 mg/kg, respectively, remaining in compliance with the limits stipulated by China's Ministry of Agriculture. The copper contents were 7.73–63.71 mg/kg; only 64% of these values complied with the standards stipulated by the Ministry of Agriculture. The nickel contents ranged from 2.70 mg/kg to 13.41 mg/kg. Consequently, more attention must be paid to the risks of heavy metal contamination in tea. The quantitative method established in this work lays a foundation for preventing heavy metal toxicity in human from drinking tea and will help establish regulations to control the contents of heavy metals in tea.

  8. Development of an analytical method for the determination of arsenic in gasoline samples by hydride generation-graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Emilene M. [Universidade Federal do Pampa, Bage, RS (Brazil); Universidade Federal de Pelotas, Pelotas, RS (Brazil); Dessuy, Morgana B.; Boschetti, Wiliam [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, Av. Bento Goncalves, 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R., E-mail: mgrvale@ufrgs.br [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, Av. Bento Goncalves, 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Ferreira, Sergio L.C. [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Instituto de Quimica, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900 Florianopolis, SC (Brazil)

    2012-05-15

    The purpose of the present work was to optimize the conditions for the determination of arsenic in gasoline with hydride generation-graphite furnace atomic absorption spectrometry after acid digestion using a full two-level factorial design with center point. The arsine was generated in a batch system and collected in a graphite tube coated with 150 {mu}g Ir as a permanent modifier. The sample volume, the pre-reduction conditions, the temperature program and modifier mass were kept fixed for all experiments. The estimated main effects were: reducing agent concentration (negative effect), acid concentration (negative effect) and trapping temperature (positive effect). It was observed that there were interactions between the variables. Moreover, the curvature was significant, indicating that the best conditions were at the center point. The optimized parameters for arsine generation were 2.7 mol L{sup -1} hydrochloric acid and 1.6% (w/v) sodium tetrahydroborate. The optimized conditions to collect arsine in the graphite furnace were a trapping temperature of 250 Degree-Sign C and a collection time of 30 s. The limit of detection was 6.4 ng L{sup -1} and the characteristic mass was 24 pg. Two different systems for acid digestion were used: a digester block with cold finger and a microwave oven. The concentration of arsenic found with the proposed method was compared with that obtained using a detergentless microemulsion and direct graphite furnace determination. The results showed that the factorial design is a simple tool that allowed establishing the appropriate conditions for sample preparation and also helped in evaluating the interaction between the factors investigated. - Highlights: Black-Right-Pointing-Pointer We determined As in gasoline using hydride generation-graphite furnace AAS. Black-Right-Pointing-Pointer We compared three sample preparation procedures. Black-Right-Pointing-Pointer A multivariate approach was used to optimize the conditions. Black

  9. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples

    Directory of Open Access Journals (Sweden)

    Xiupei Yang

    2017-03-01

    Full Text Available A cloud point extraction (CPE method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I/diethyldithiocarbamate (DDTC complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL−1 Ag+ in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL−1 for both Zn2+ and Cu2+, 80 μg·mL−1 for Pb2+, 1000 μg·mL−1 for Mn2+, and 100 μg·mL−1 for both Cd2+ and Ni2+. The calibration curve was linear in the range of 1–500 ng·mL−1 with a limit of detection (LOD at 0.3 ng·mL−1. The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  10. L-tyrosine immobilized on multiwalled carbon nanotubes: a new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Pacheco, Pablo H; Gil, Raúl A; Smichowski, Patricia; Polla, Griselda; Martinez, Luis D

    2009-12-10

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 micromol of Tl(III) g(-1) of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3sigma) by STPF-ETAAS was 150 ng L(-1). The detection limit (3sigma) for Tl(III) employing the separation system was 3 ng L(-1), with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 microg L(-1) of Tl(III), and 3.69-3.91 microg L(-1) of total thallium.

  11. Determination of Pb (Lead), Cd (Cadmium), Cr (Chromium), Cu (Copper), and Ni (Nickel) in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Zhong, Wen-Si; Ren, Ting; Zhao, Li-Jiao

    2016-01-01

    The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory analytical precisions (represented by relative standard deviations ranging from 0.6% to 2.5%) and recoveries (98.91-101.32%). The lead contents in tea leaves were 0.48-10.57 mg/kg, and 80% of these values were below the maximum values stated by the guidelines in China. The contents of cadmium and chromium ranged from 0.01 mg/kg to 0.39 mg/kg and from 0.27 mg/kg to 2.45 mg/kg, respectively, remaining in compliance with the limits stipulated by China's Ministry of Agriculture. The copper contents were 7.73-63.71 mg/kg; only 64% of these values complied with the standards stipulated by the Ministry of Agriculture. The nickel contents ranged from 2.70 mg/kg to 13.41 mg/kg. Consequently, more attention must be paid to the risks of heavy metal contamination in tea. The quantitative method established in this work lays a foundation for preventing heavy metal toxicity in human from drinking tea and will help establish regulations to control the contents of heavy metals in tea. Copyright © 2015. Published by Elsevier B.V.

  12. Simple hollow fiber renewal liquid membrane extraction method for pre-concentration of Cd(II) in environmental samples and detection by Flame Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Carletto, Jeferson Schneider; Luciano, Raquel Medeiros; Bedendo, Gizelle Cristina; Carasek, Eduardo

    2009-01-01

    A hollow fiber renewal liquid membrane (HFRLM) extraction method to determine cadmium (II) in water samples using Flame Atomic Absorption Spectrometry (FAAS) was developed. Ammonium O,O-diethyl dithiophosphate (DDTP) was used to complex cadmium (II) in an acid medium to obtain a neutral hydrophobic complex (ML 2 ). The organic solvent introduced to the sample extracts this complex from the aqueous solution and carries it over the poly(dimethylsiloxane) (PDMS) membrane, that had their walls previously filled with the same organic solvent. The organic solvent is solubilized inside the PDMS membrane, leading to a homogeneous phase. The complex strips the lumen of the membrane where, at higher pH, the complex Cd-DDTP is broken down and cadmium (II) is released into the stripping phase. EDTA was used to complex the cadmium (II), helping to trap the analyte in the stripping phase. A multivariate procedure was used to optimize the studied variables. The optimized variables were: sample (donor phase) pH 3.25, DDTP concentration 0.05% (m/v), stripping (acceptor phase) pH 8.75, EDTA concentration 1.5 x 10 -2 mol L -1 , extraction temperature 40 deg. C, extraction time 40 min, a solvent mixture N-butyl acetate and hexane (60/40%, v/v) with a volume of 100 μL, and addition of ammonium sulfate to saturate the sample. The sample volume used was 20 mL and the stripping volume was 165 μL. The analyte enrichment factor was 120, limit of detection (LOD) 1.3 μg L -1 , relative standard deviation (RSD) 5.5% and the working linear range 2-30 μg L -1 .

  13. L-Tyrosine immobilized on multiwalled carbon nanotubes: A new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Pablo H.; Gil, Raul A. [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina); Smichowski, Patricia, E-mail: smichows@cnea.gov.ar [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, CP C1033 AAJ, Ciudad de Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral. Paz 1499, B1650KNA San Martin (Argentina); Polla, Griselda [Comision Nacional de Energia Atomica, Gerencia de Investigacion y Aplicaciones, Av.Gral. Paz 1499, B1650KNA San Martin (Argentina); Martinez, Luis D., E-mail: ldm@unsl.edu.ar [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina)

    2009-12-10

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 {mu}mol of Tl(III) g{sup -1} of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3{sigma}) by STPF-ETAAS was 150 ng L{sup -1}. The detection limit (3{sigma}) for Tl(III) employing the separation system was 3 ng L{sup -1}, with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 {mu}g L{sup -1} of Tl(III), and 3.69-3.91 {mu}g L{sup -1} of total thallium.

  14. Hollow fiber liquid phase microextraction combined with electrothermal atomic absorption spectrometry for the speciation of arsenic (III) and arsenic (V) in fresh waters and human hair extracts

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Hongmei [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin [Department of Chemistry, Wuhan University, Wuhan 430072 (China)], E-mail: binhu@whu.edu.cn; Chen Beibei; Xia Linbo [Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2009-02-16

    A new method of hollow fiber liquid phase microextraction (HF-LPME) using ammonium pyrrolidine dithiocarbamate (APDC) as extractant combined with electrothermal atomic absorption spectrometry (ETAAS) using Pd as permanent modifier has been described for the speciation of As(III) and As(V). In a pH range of 3.0-4.0, the complex of As(III)-APDC complex can be extracted using toluene as the extraction solvent leaving As(V) in the aqueous layer. The post extraction organic phase was directly injected into ETAAS for the determination of As(III). To determine total arsenic in the samples, first As(V) was reduced to As(III) by L-cysteine, and then a microextraction method was performed prior to the determination of total arsenic. As(V) assay was based on subtracting As(III) form the total arsenic. All parameters, such as pH of solution, type of organic solvent, the amount of APDC, stirring rate and extraction time, affecting the separation of As(III) from As(V) and the extraction efficiency of As(III) were investigated, and the optimized extraction conditions were established. Under optimized conditions, a detection limit of 0.12 ng mL{sup -1} with enrichment factor of 78 was achieved. The relative standard deviation (R.S.D.) of the method for five replicate determinations of 5 ng mL{sup -1} As(III) was 8%. The developed method was applied to the speciation of As(III) and As(V) in fresh water and human hair extracts, and the recoveries for the spiked samples are 86-109%. In order to validate the developed method, three certified reference materials such as GBW07601 human hair, BW3209 and BW3210 environmental water were analyzed, and the results obtained were in good agreement with the certified values provided.

  15. Ultratrace determination of arsenic in water samples by electrothermal atomic absorption spectrometry after pre-concentration with Mg-Al-Fe ternary layered double hydroxide nano-sorbent.

    Science.gov (United States)

    Abdolmohammad-Zadeh, Hossein; Jouyban, Abolghasem; Amini, Roghayeh

    2013-11-15

    A selective solid phase extraction method, based on nano-structured Mg-Al-Fe(NO3(-)) ternary layered double hydroxide as a sorbent, is developed for the pre-concentration of ultra-trace levels of arsenic (As) prior to determination by electrothermal atomic absorption spectrometry. It is found that both As(III) and As(V) could be quantitatively retained on the sorbent within a wide pH range of 4-12. Accordingly, the presented method is applied to determination of total inorganic As in aqueous solutions. Maximum analytical signal of As is achieved when the pyrolysis and atomization temperatures are close to 900 °C and 2300 °C, respectively. Several variables affecting the extraction efficiency including pH, sample flow rate, amount of nano-sorbent, elution conditions and sample volume are optimized. Under the optimized conditions, the limit of detection (3Sb/m) and the relative standard deviation are 4.6 pg mL(-1) and 3.9%, respectively. The calibration graph is linear in the range of 15.0-650 pg mL(-1) with a correlation coefficient of 0.9979, sorption capacity and pre-concentration factor are 8.68 mg g(-1) and 300, respectively. The developed method is validated by the analysis of a standard reference material (SRM 1643e) and is successfully applied to the determination of ultra-trace amounts of As in different water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. L-Tyrosine immobilized on multiwalled carbon nanotubes: A new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pacheco, Pablo H.; Gil, Raul A.; Smichowski, Patricia; Polla, Griselda; Martinez, Luis D.

    2009-01-01

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 μmol of Tl(III) g -1 of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3σ) by STPF-ETAAS was 150 ng L -1 . The detection limit (3σ) for Tl(III) employing the separation system was 3 ng L -1 , with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 μg L -1 of Tl(III), and 3.69-3.91 μg L -1 of total thallium.

  17. Multiple response optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry with sample injection as detergent emulsion

    International Nuclear Information System (INIS)

    Brum, Daniel M.; Lima, Claudio F.; Robaina, Nicolle F.; Fonseca, Teresa Cristina O.; Cassella, Ricardo J.

    2011-01-01

    The present paper reports the optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry (GF AAS) employing a strategy based on the injection of the samples as detergent emulsions. The method was optimized in relation to the experimental conditions for the emulsion formation and taking into account that the three analytes (Cu, Fe and Pb) should be measured in the same emulsion. The optimization was performed in a multivariate way by employing a three-variable Doehlert design and a multiple response strategy. For this purpose, the individual responses of the three analytes were combined, yielding a global response that was employed as a dependent variable. The three factors related to the optimization process were: the concentration of HNO 3 , the concentration of the emulsifier agent (Triton X-100 or Triton X-114) in aqueous solution used to emulsify the sample and the volume of solution. At optimum conditions, it was possible to obtain satisfactory results with an emulsion formed by mixing 4 mL of the samples with 1 mL of a 4.7% w/v Triton X-100 solution prepared in 10% v/v HNO 3 medium. The resulting emulsion was stable for 250 min, at least, and provided enough sensitivity to determine the three analytes in the five samples tested. A recovery test was performed to evaluate the accuracy of the optimized procedure and recovery rates, in the range of 88-105%; 94-118% and 95-120%, were verified for Cu, Fe and Pb, respectively.

  18. Combining single-particle inductively coupled plasma mass spectrometry and X-ray absorption spectroscopy to evaluate the release of colloidal arsenic from environmental samples.

    Science.gov (United States)

    Gomez-Gonzalez, Miguel Angel; Bolea, Eduardo; O'Day, Peggy A; Garcia-Guinea, Javier; Garrido, Fernando; Laborda, Francisco

    2016-07-01

    Detection and sizing of natural colloids involved in the release and transport of toxic metals and metalloids is essential to understand and model their environmental effects. Single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) was applied for the detection of arsenic-bearing particles released from mine wastes. Arsenic-bearing particles were detected in leachates from mine wastes, with a mass-per-particle detection limit of 0.64 ng of arsenic. Conversion of the mass-per-particle information provided by SP-ICP-MS into size information requires knowledge of the nature of the particles; therefore, synchrotron-based X-ray absorption spectroscopy (XAS) was used to identify scorodite (FeAsO4·2H2O) as the main species in the colloidal particles isolated by ultrafiltration. The size of the scorodite particles detected in the leachates was below 300-350 nm, in good agreement with the values obtained by TEM. The size of the particles detected by SP-ICP-MS was determined as the average edge of scorodite crystals, which show a rhombic dipyramidal form, achieving a size detection limit of 117 nm. The combined use of SP-ICP-MS and XAS allowed detection, identification, and size determination of scorodite particles released from mine wastes, suggesting their potential to transport arsenic. Graphical abstract Analytical approach for the detection and size characterization of As-bearing particles by SP-ICP-MS and XAS in environmental samples.

  19. Supramolecular-Based Ultrasonic-Assisted Dispersion Solidification Liquid-Liquid Microextraction of Copper and Cobalt Prior to Their Flame Atomic Absorption Spectrometry Determination.

    Science.gov (United States)

    Shokrollahi, Ardeshir; Ebrahimi, Foroogh

    2017-11-01

    In the present work, a simple, efficient, and environmentally friendly method was proposed for the simultaneous preconcentration and determination of minute quantities of copper and cobalt in water samples and serum by a supramolecular-based ultrasonic-assisted dispersion solidification liquid-liquid microextraction (DSLLME) procedure coupled with flame atomic absorption spectrometry. The procedure is based on the DSLLME of copper and cobalt with decanoic acid-tetrahydrofuran supramolecular solvent (SUPRAS) in the presence of sodium diethyldithiocarbamate, as the complexing agent. SUPRAS is a nanostructured liquid generated from amphiphiles through a sequential self-assembly process occurring on two scales, molecular and nano. Several variables that affect the extraction efficiency-including pH, concentration of complexing agent, volume of the extraction and dispersive solvents (volume of SUPRAS), sonication time, and ionic strength-were investigated and optimized. The method provided enrichment factors of 23.31 and 22.38 for copper and cobalt, respectively. The preconcentration factor for the two analytes was 20.00. Calibration plots were linear in the range of 5.00-700.00 ng/mL for copper and 5.00-500.00 ng/mL for cobalt, with correlations of determination of 0.9973 and 0.9981. The precision of the method were expressed as RSDs for six replicate measurements and LODs and found to be ±4.10 and ±2.30% for copper and 2.90 and 3.50 ng/mL for cobalt. The proposed method was successfully applied to the simultaneous determination of trace copper and cobalt in real water samples and serum with satisfactory results.

  20. In situ metathesis ionic liquid formation dispersive liquid-liquid microextraction for copper determination in water samples by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Stanisz, Ewa; Zgoła-Grześkowiak, Agnieszka

    2013-10-15

    In situ synthesis of ionic liquid extractant for dispersive liquid-liquid microextraction (in situ IL DLLME) combined with electrothermal atomic absorption spectrometry (ET AAS) for determination of copper in water samples was developed. Analytical signals were obtained without the back-extraction of copper from the IL phase prior to its determination by AAS. Some essential parameters of the microextraction and detection techniques such as the pH of sample solution, volume of components for in situ synthesis, matrix interferences and main parameters of graphite furnace atomizer have been studied. Under optimal conditions, high extraction efficiency for copper was achieved for the extraction of 0.7 µg L(-1) in 10.0 mL of sample solution employing 8 μL of 1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide (HmimNTf2) as the extraction solvent. The detection limit was found as 0.004 µg L(-1) with an enrichment factor of 200. The relative standard deviation (RSD) for seven replicate measurements of 0.7 µg L(-1) in sample solution was 4%. The accuracy of the proposed method was evaluated by analysis of the Certified Reference Materials: NIST SRM 2709 (San Joaquin Soil), NBS SRM 2704 (Buffalo River Sediment), NRCC DOLT-2 (Dogfish Liver) and NIST SRM 1643e (Trace Element in Water). The measured copper contents in the reference materials were in satisfactory agreement with the certified values. The method was successfully applied to analysis of the tap, lake and mineral water samples. © 2013 Elsevier B.V. All rights reserved.

  1. Ethylene hydrogenation catalysis on Pt(111) single-crystal surfaces studied by using mass spectrometry and in situ infrared absorption spectroscopy

    Science.gov (United States)

    Tillekaratne, Aashani; Simonovis, Juan Pablo; Zaera, Francisco

    2016-10-01

    The catalytic hydrogenation of ethylene promoted by a Pt(111) single crystal was studied by using a ultrahigh-vacuum surface-science instrument equipped with a so-called high-pressure cell. Kinetic data were acquired continuously during the catalytic conversion of atmospheric-pressure mixtures of ethylene and hydrogen by using mass spectrometry while simultaneously characterizing the surface species in operando mode by reflection-absorption infrared spectroscopy (RAIRS). Many observations reported in previous studies of this system were corroborated, including the presence of adsorbed alkylidyne intermediates during the reaction and the zero-order dependence of the rate of hydrogenation on the pressure of ethylene. In addition, the high quality of the kinetic data, which could be recorded continuously versus time and processed to calculate time-dependent turnover frequencies (TOFs), afforded a more detailed analysis of the mechanism. Specifically, deuterium labeling could be used to estimate the extent of isotope scrambling reached with mixed-isotope-substituted reactants (C2H4 + D2 and C2D4 + H2). Perhaps the most important new observation from this work is that, although extensive H-D exchange takes place on ethylene before being fully converted to ethane, the average stoichiometry of the final product retains the expected stoichiometry of the gas mixture, that is, four regular hydrogen atoms and two deuteriums per ethane molecule in the case of the experiments with C2H4 + D2. This means that no hydrogen atoms are removed from the surface via their inter-recombination to produce X2 (X = H or D). It is concluded that, under catalytic conditions, hydrogen surface recombination is much slower than ethylene hydrogenation and H-D exchange.

  2. Non-chromatographic screening procedure for arsenic speciation analysis in fish-based baby foods by using electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lopez-Garcia, Ignacio; Briceno, Marisol; Hernandez-Cordoba, Manuel

    2011-01-01

    Highlights: → Arsenic in fish-based food samples can be determined without the need of a dissolution stage. → Speciation of the main forms of arsenic in fish-based baby foods does not require chromatography. → The behavior of arsenic compounds in ETAAS strongly depends on the chemical modifier used. - Abstract: A procedure for the speciation analysis of arsenic in fish-based baby foods is presented. Inorganic arsenic, methylarsonic acid (MA), dimethylarsinic acid (DMA) and arsenobetaine (AB) were determined by electrothermal atomic absorption spectrometry (ETAAS) using suspensions prepared in a 0.01 mol L -1 tetramethylammonium hydroxide (TMAH) solution. Speciation is based on the use of three different chemically modified ETAAS atomizers to obtain the analytical signals. Using a palladium salt as the chemical modifier, the signal corresponding to the total arsenic concentration is obtained. When palladium is replaced by Ce(IV), the signal is solely due to inorganic arsenic (III and V) + MA. If no signal is obtained in this latter case, it is possible to distinguish between DMA and AB using a zirconium coated atomizer. The signal obtained in this way is due solely to DMA, and the concentration of AB can be obtained by the difference with the total arsenic content. Determinations by ETAAS require the use of the standard additions method. The limits of detection for the determination of AB, DMA and inorganic arsenic (+MA) are 15, 25 and 50 ng g -1 expressed as arsenic, respectively. These detection limits are good enough for the procedure to be appropriate for the rapid determination of these compounds, avoiding extraction processes and/or chromatographic separations. Data for commercial samples, as well as for four standard reference materials, are given.

  3. Investigation of chemical modifiers for the determination of lead in fertilizers and limestone using graphite furnace atomic absorption spectrometry with Zeeman-effect background correction and slurry sampling

    Science.gov (United States)

    Borges, Aline R.; Becker, Emilene M.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Welz, Bernhard

    2014-02-01

    In this work, chemical modifiers in solution (Pd/Mg, NH4H2PO4 and NH4NO3/Pd) were compared with permanent modifiers (Ir and Ru) for the determination of lead in fertilizer and limestone samples using slurry sampling and graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. The analytical line at 283.3 nm was used due to some spectral interference observed at 217.0 nm. The NH4H2PO4 was abandoned due to severe spectral interference even at the 283.3-nm line. For Pd/Mg and NH4NO3/Pd the optimum pyrolysis and atomization temperatures were 900 °C and 1900 °C, respectively. For Ru and Ir, the integrated absorbance signal was stable up to pyrolysis temperatures of 700 °C and 900 °C, respectively, and up to atomization temperature of 1700 °C. The limit of detection (LOD) was 17 ng g- 1 using Pd/Mg and 29 ng g- 1 using NH4NO3/Pd. Among the permanent modifiers investigated, the LOD was 22 ng g- 1 Pb for Ir and 10 ng g- 1 Pb for Ru. The accuracy of the method was evaluated using the certified reference material NIST SRM 695. Although Ru provided lower LOD, which can be attributed to a lower blank signal, only the modifiers in solution showed concordant values of Pb concentration for the NIST SRM 695 and the most of analyzed samples. Moreover, the Pd/Mg modifier provided the highest sensitivity and for this reason it is more suitable for the determination of Pb in fertilizers samples in slurry; besides this it presented a better signal-to-noise ratio than NH4NO3/Pd.

  4. Development of an analytical model for the determination of 60Co in aqueous samples by atomic absorption and gamma spectrometry techniques

    International Nuclear Information System (INIS)

    Solis A, N. A.

    2015-01-01

    The applications of the nuclear energy in industry and medicine generate radioactive wastes that must be isolated and confined in order to limit its spread in the biosphere. These types of wastes are generated in hospitals, industry, research centers and nuclear power plants (during de fuel cycle). The radioactive elements (radionuclides) cannot be destroyed by any known method, either chemical or mechanical. Its final destruction is produced by radioactive decay, which makes them stable isotopes, or nuclear transmutation being bombarded with atomic particles. Consequently, the radioactive waste management is to control the radioactive discharges and reduce to tolerable limits, eliminating of effluents and wastes the radionuclides of interest, concentrating them so they can be stored or evacuated so that later not appear in dangerous concentration in the biosphere. In Mexico, the main generators of radioactive wastes are the nuclear power plant of Laguna Verde in Veracruz, Hospitals of the public and private sector, in addition Instituto Nacional de Investigaciones Nucleares (ININ) some institutes and facilities of the UNAM and Instituto Politecnico Nacional (IPN) and industries among others. The aqueous radioactive wastes, particularly those from the nuclear power plants contain traces of cobalt-60. Currently there is no model or analytical technique for the separation of this radionuclide, so it became necessary to develop an analytical model for separation and facilitate their disposal. In this paper was shown that atomic absorption and gamma spectrometry techniques can separate the active concentration of the inactive, which is important because the total concentration can be associated through direct relationships with the wear of metal parts of the nuclear reactor, since the metal alloys of the same reactor containing a fraction of cobalt. Also this analytical and mathematical model that can be reproducible and applicable to full sets of samples and that this

  5. Ultrasound-assisted single-drop microextraction for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry

    Science.gov (United States)

    Almeida, Jorge S.; Anunciação, Taiana A.; Brandão, Geovani C.; Dantas, Alailson F.; Lemos, Valfredo A.; Teixeira, Leonardo S. G.

    2015-05-01

    This work presents an ultrasound-assisted single-drop microextraction procedure for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry. Some initial tests showed that the best extraction efficiency was obtained when using ultrasound instead of mechanical agitation, indicating that acoustic cavitation improved the extraction process. Nitric, hydrochloric and acetic acids were evaluated for use in the extraction process, and HNO3 gave the best results. A two-level full-factorial design was applied to investigate the best conditions for the extraction of Cd from the oil samples. The influences of the sonication amplitude, time and temperature of the extraction were evaluated. The results of the design revealed that all of the variables had a significant effect on the experimental results. Afterward, a Box-Behnken design was applied to determine the optimum conditions for the determination of cadmium in vegetable oil samples. According to a multivariate study, the optimum conditions were as follows: sonication amplitude of 60%, extraction time of 15 min, extraction temperature of 46 °C and 0.1 mol L- 1 HNO3 as the extractor solution. Under optimized conditions, the developed method allows for the determination of Cd in oil samples with a limit of quantification of 7.0 ng kg- 1. Addition and recovery experiments were performed in vegetable oil samples to evaluate the accuracy of the method, and the recoveries obtained varied from 90% to 115%. The samples were also analyzed after the acid digestion procedure, and the paired t-test (95% confidence level) did not show significant differences from the proposed method.

  6. Ultrasound-assisted single-drop microextraction for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Jorge S.; Anunciação, Taiana A. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Brandão, Geovani C. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); INCT de Energia e Ambiente, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Dantas, Alailson F. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Lemos, Valfredo A. [Laboratório de Química Analítica (LQA), Universidade Estadual do Sudoeste da Bahia, Campus de Jequié, Jequié, Bahia 45506-191 (Brazil); and others

    2015-05-01

    This work presents an ultrasound-assisted single-drop microextraction procedure for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry. Some initial tests showed that the best extraction efficiency was obtained when using ultrasound instead of mechanical agitation, indicating that acoustic cavitation improved the extraction process. Nitric, hydrochloric and acetic acids were evaluated for use in the extraction process, and HNO{sub 3} gave the best results. A two-level full-factorial design was applied to investigate the best conditions for the extraction of Cd from the oil samples. The influences of the sonication amplitude, time and temperature of the extraction were evaluated. The results of the design revealed that all of the variables had a significant effect on the experimental results. Afterward, a Box–Behnken design was applied to determine the optimum conditions for the determination of cadmium in vegetable oil samples. According to a multivariate study, the optimum conditions were as follows: sonication amplitude of 60%, extraction time of 15 min, extraction temperature of 46 °C and 0.1 mol L{sup −1} HNO{sub 3} as the extractor solution. Under optimized conditions, the developed method allows for the determination of Cd in oil samples with a limit of quantification of 7.0 ng kg{sup −1}. Addition and recovery experiments were performed in vegetable oil samples to evaluate the accuracy of the method, and the recoveries obtained varied from 90% to 115%. The samples were also analyzed after the acid digestion procedure, and the paired t-test (95% confidence level) did not show significant differences from the proposed method. - Highlights: • The determination of cadmium in vegetable oils was developed using UA-SDME. • HR-CS ET-AAS was employed as a detection technique with direct drop sampling. • The procedure allowed for a reduction in the consumption of reagents and

  7. Speciation of copper and zinc in size-fractionated atmospheric particulate matter using total reflection mode X-ray absorption near-edge structure spectrometry

    International Nuclear Information System (INIS)

    Osan, Janos; Meirer, Florian; Groma, Veronika; Toeroek, Szabina; Ingerle, Dieter; Streli, Christina; Pepponi, Giancarlo

    2010-01-01

    The health effects of aerosol depend on the size distribution and the chemical composition of the particles. Heavy metals of anthropogenic origin are bound to the fine aerosol fraction (PM 2.5 ). The composition and speciation of aerosol particles can be variable in time, due to the time-dependence of anthropogenic sources as well as meteorological conditions. Synchrotron-radiation total reflection X-ray fluorescence (SR-TXRF) provides very high sensitivity for characterization of atmospheric particulate matter. X-ray absorption near-edge structure (XANES) spectrometry in conjunction with TXRF detection can deliver speciation information on heavy metals in aerosol particles collected directly on the reflector surface. The suitability of TXRF-XANES for copper and zinc speciation in size-fractionated atmospheric particulate matter from a short sampling period is presented. For high size resolution analysis, atmospheric aerosol particles were collected at different urban and rural locations using a 7-stage May cascade impactor having adapted for sampling on Si wafers. The thin stripe geometry formed by the particulate matter deposited on the May-impactor plates is ideally suited to SR-TXRF. Capabilities of the combination of the May-impactor sampling and TXRF-XANES measurements at HASYLAB Beamline L to Cu and Zn speciation in size-fractionated atmospheric particulate matter are demonstrated. Information on Cu and Zn speciation could be performed for elemental concentrations as low as 140 pg/m 3 . The Cu and Zn speciation in the different size fraction was found to be very distinctive for samples of different origin. Zn and Cu chemical state typical for soils was detected only in the largest particles studied (2-4 μm fraction). The fine particles, however, contained the metals of interest in the sulfate and nitrate forms.

  8. A new supramolecular based liquid solid microextraction method for preconcentration and determination of trace bismuth in human blood serum and hair samples by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Kahe, Hadi; Chamsaz, Mahmoud

    2016-11-01

    A simple and reliable supramolecule-aggregated liquid solid microextraction method is described for preconcentration and determination of trace amounts of bismuth in water as well as human blood serum and hair samples. Catanionic microstructures of cetyltrimethylammonium bromide (CTAB) and sodium dodecyl sulfate (SDS) surfactants, dissolved in deionized water/propanol, are used as a green solvent to extract bismuth (III)-diethyldithiocarbamate complexes by dispersive microextraction methodology. The extracted solid phase is easily removed and dissolved in 50 μL propanol for subsequent measurement by electrothermal atomic absorption spectrometry (ET-AAS). The procedure benefits the merits of supramolecule aggregates' properties and dispersive microextraction technique using water as the main component of disperser solvent, leading to direct interaction with analyte. Phase separation behavior of extraction solvent and different parameters influencing the extraction efficiency of bismuth ion such as salt concentration, pH, centrifugation time, amount of chelating agent, SDS:CTAB mole ratio, and solvent amounts were thoroughly optimized. Under the optimal experimental conditions, the calibration curve was linear in the range of 0.3-6 μg L -1 Bi (III) with a limit of detection (LOD) of 0.16 μg L -1 (S/N = 3). The relative standard deviations (RSD) of determination were obtained to be 5.1 and 6.2 % for 1 and 3 μg L -1 of Bi (III), respectively. The developed method was successfully applied as a sensitive and accurate technique for determination of bismuth ion in human blood serum, hair samples, and a certified reference material.

  9. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples.

    Science.gov (United States)

    Yang, Xiupei; Jia, Zhihui; Yang, Xiaocui; Li, Gu; Liao, Xiangjun

    2017-03-01

    A cloud point extraction (CPE) method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS) The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I)/diethyldithiocarbamate (DDTC) complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I)/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL -1 Ag + in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL -1 for both Zn 2+ and Cu 2+ , 80 μg·mL -1 for Pb 2+ , 1000 μg·mL -1 for Mn 2+ , and 100 μg·mL -1 for both Cd 2+ and Ni 2+ . The calibration curve was linear in the range of 1-500 ng·mL -1 with a limit of detection (LOD) at 0.3 ng·mL -1 . The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  10. Development of new portable miniaturize solid phase microextraction of silver-APDC complex using micropipette tip in-syringe system couple with electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Naeemullah; Kazi, Tasneem Gul; Afridi, Hassan Imran; Shah, Faheem; Arain, Sadaf Sadia; Arain, Salma Aslam; Panhwar, Abdul Haleem; Arain, Mariam Shahzadi; Samoon, Muhammad Kashif

    2016-02-05

    An innovative and simple miniaturized solid phase microextraction (M-SPME) method, was developed for preconcentration and determination of silver(I) in the fresh and waste water samples. For M-SPME, a micropipette tip packed with activated carbon cloth (ACC) as sorbent, in a syringe system. The size, morphology and elemental composition of ACC before and after adsorption of analyte have been characterized by scanning electron microscopy and energy dispersive spectroscopy. The sample solution treated with a complexing reagent, ammonium pyrrolidine dithiocarbamate (APDC), was drawn into the syringe filled with ACC and dispensed manually for 2 to 10 aspirating/dispensing cycle. Then the Ag- complex sorbed on the ACC in micropipette was quantitatively eluted by drawing and dispensing of different concentrations of acids for 2 to 5 aspirating/dispensing cycles. The extracted Ag ions with modifier were injected directly into the electrothermal atomic absorption spectrometry for analysis. The influence of different variables on the extraction efficiency, including the concentration of ligand, pH, sample volume, eluent type, concentration and volume was investigated. Validity and accuracy of the developed method was checked by the standard addition method. Reliability of the proposed methodology was checked by the relative standard deviation (%RSD), which was found to be <5%. Under the optimized experimental variables, the limits of detection (LOD) and enhancement factors (EF), were obtained to be 0.86 ng L(-1) and 120, respectively. The proposed method was successfully applied for the determination of trace levels of silver ions in fresh and waste water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Iron species determination by task-specific ionic liquid-based in situ solvent formation dispersive liquid-liquid microextraction combined with flame atomic absorption spectrometry.

    Science.gov (United States)

    Sadeghi, Susan; Ashoori, Vahid

    2017-10-01

    The task-specific ionic liquid (TSIL) of 1-ethyl-3-methylimidazolium bromide functionalized with 8-hydroxyquinoline was used as a chelating agent and extracting solvent for dispersive liquid-liquid microextraction and subsequent determination of Fe(III) by flame atomic absorption spectrometry. The in situ solvent formation of TSIL using KPF 6 provided the desired water-immiscible ionic liquid. The total Fe concentration could be determined after pre-oxidation of Fe(II) to Fe(III). Various factors affecting the proposed extraction procedure were optimized. The proposed analytical conditions were: sample pH 5, TSIL amount 0.3% (w/v), KPF 6 amount 0.15% (w/v), anti-sticking 0.1% (w/v) and salt concentration 5% (w/v). Under optimal conditions, the linear dynamic ranges for Fe(III) and total Fe were 20-80 and 20-110 ng mL -1 , respectively, with a detection limit of 6.9 ng mL -1 for Fe(III) and relative standard deviation of 2.2%. The proposed method was successfully applied to the determination of trace Fe(III) in water (underground, tap, refined water and artificial sea water) and beverage (apple, tomato, and tea) samples. The developed method offers advantages such as simplicity, ease of operation, and extraction of Fe(III) from aqueous solutions without the use of organic solvent. It was successfully applied for iron speciation in different real samples. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  12. Preconcentration and determination of vanadium and molybdenum in milk, vegetables and foodstuffs by ultrasonic-thermostatic-assisted cloud point extraction coupled to flame atomic absorption spectrometry.

    Science.gov (United States)

    Gürkan, Ramazan; Korkmaz, Sema; Altunay, Nail

    2016-08-01

    A new ultrasonic-thermostatic-assisted cloud point extraction procedure (UTA-CPE) was developed for preconcentration at the trace levels of vanadium (V) and molybdenum (Mo) in milk, vegetables and foodstuffs prior to determination via flame atomic absorption spectrometry (FAAS). The method is based on the ion-association of stable anionic oxalate complexes of V(V) and Mo(VI) with [9-(diethylamino)benzo[a]phenoxazin-5-ylidene]azanium; sulfate (Nile blue A) at pH 4.5, and then extraction of the formed ion-association complexes into micellar phase of polyoxyethylene(7.5)nonylphenyl ether (PONPE 7.5). The UTA-CPE is greatly simplified and accelerated compared to traditional cloud point extraction (CPE). The analytical parameters optimized are solution pH, the concentrations of complexing reagents (oxalate and Nile blue A), the PONPE 7.5 concentration, electrolyte concentration, sample volume, temperature and ultrasonic power. Under the optimum conditions, the calibration curves for Mo(VI) and V(V) are obtained in the concentration range of 3-340µgL(-1) and 5-250µgL(-1) with high sensitivity enhancement factors (EFs) of 145 and 115, respectively. The limits of detection (LODs) for Mo(VI) and V(V) are 0.86 and 1.55µgL(-1), respectively. The proposed method demonstrated good performances such as relative standard deviations (as RSD %) (≤3.5%) and spiked recoveries (95.7-102.3%). The accuracy of the method was assessed by analysis of two standard reference materials (SRMs) and recoveries of spiked solutions. The method was successfully applied into the determination of trace amounts of Mo(VI) and V(V) in milk, vegetables and foodstuffs with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis.

    Science.gov (United States)

    Silva, Arlene S; Brandao, Geovani C; Matos, Geraldo D; Ferreira, Sergio L C

    2015-11-01

    The present work proposed an analytical method for the direct determination of chromium in infant formulas employing the high-resolution continuum source electrothermal atomic absorption spectrometry combined with the solid sample analysis (SS-HR-CS ET AAS). Sample masses up to 2.0mg were directly weighted on a solid sampling platform and introduced into the graphite tube. In order to minimize the formation of carbonaceous residues and to improve the contact of the modifier solution with the solid sample, a volume of 10 µL of a solution containing 6% (v/v) H2O2, 20% (v/v) ethanol and 1% (v/v) HNO3 was added. The pyrolysis and atomization temperatures established were 1600 and 2400 °C, respectively, using magnesium as chemical modifier. The calibration technique was evaluated by comparing the slopes of calibration curves established using aqueous and solid standards. This test revealed that chromium can be determined employing the external calibration technique using aqueous standards. Under these conditions, the method developed allows the direct determination of chromium with limit of quantification of 11.5 ng g(-1), precision expressed as relative standard deviation (RSD) in the range of 4.0-17.9% (n=3) and a characteristic mass of 1.2 pg of chromium. The accuracy was confirmed by analysis of a certified reference material of tomato leaves furnished by National Institute of Standards and Technology. The method proposed was applied for the determination of chromium in five different infant formula samples. The chromium content found varied in the range of 33.9-58.1 ng g(-1) (n=3). These samples were also analyzed employing ICP-MS. A statistical test demonstrated that there is no significant difference between the results found by two methods. The chromium concentrations achieved are lower than the maximum limit permissible for chromium in foods by Brazilian Legislation. Copyright © 2015. Published by Elsevier B.V.

  14. Speciation of copper and zinc in size-fractionated atmospheric particulate matter using total reflection mode X-ray absorption near-edge structure spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Osan, Janos, E-mail: osan@aeki.kfki.hu [Hungarian Academy of Sciences KFKI Atomic Energy Research Institute, P.O. Box 49, H-1525 Budapest (Hungary); Meirer, Florian [Fondazione Bruno Kessler, Via Sommarive 18, I-38123 Povo (Italy); Atominstitut, TU Wien, Stadionallee 2, A-1020 Vienna (Austria); Groma, Veronika; Toeroek, Szabina [Hungarian Academy of Sciences KFKI Atomic Energy Research Institute, P.O. Box 49, H-1525 Budapest (Hungary); Ingerle, Dieter; Streli, Christina [Atominstitut, TU Wien, Stadionallee 2, A-1020 Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Via Sommarive 18, I-38123 Povo (Italy)

    2010-12-15

    The health effects of aerosol depend on the size distribution and the chemical composition of the particles. Heavy metals of anthropogenic origin are bound to the fine aerosol fraction (PM{sub 2.5}). The composition and speciation of aerosol particles can be variable in time, due to the time-dependence of anthropogenic sources as well as meteorological conditions. Synchrotron-radiation total reflection X-ray fluorescence (SR-TXRF) provides very high sensitivity for characterization of atmospheric particulate matter. X-ray absorption near-edge structure (XANES) spectrometry in conjunction with TXRF detection can deliver speciation information on heavy metals in aerosol particles collected directly on the reflector surface. The suitability of TXRF-XANES for copper and zinc speciation in size-fractionated atmospheric particulate matter from a short sampling period is presented. For high size resolution analysis, atmospheric aerosol particles were collected at different urban and rural locations using a 7-stage May cascade impactor having adapted for sampling on Si wafers. The thin stripe geometry formed by the particulate matter deposited on the May-impactor plates is ideally suited to SR-TXRF. Capabilities of the combination of the May-impactor sampling and TXRF-XANES measurements at HASYLAB Beamline L to Cu and Zn speciation in size-fractionated atmospheric particulate matter are demonstrated. Information on Cu and Zn speciation could be performed for elemental concentrations as low as 140 pg/m{sup 3}. The Cu and Zn speciation in the different size fraction was found to be very distinctive for samples of different origin. Zn and Cu chemical state typical for soils was detected only in the largest particles studied (2-4 {mu}m fraction). The fine particles, however, contained the metals of interest in the sulfate and nitrate forms.

  15. Method validation for control determination of mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry.

    Science.gov (United States)

    Torres, Daiane Placido; Martins-Teixeira, Maristela Braga; Cadore, Solange; Queiroz, Helena Müller

    2015-01-01

    A method for the determination of total mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry (TDA AAS) has been validated following international foodstuff protocols in order to fulfill the Brazilian National Residue Control Plan. The experimental parameters have been previously studied and optimized according to specific legislation on validation and inorganic contaminants in foodstuff. Linearity, sensitivity, specificity, detection and quantification limits, precision (repeatability and within-laboratory reproducibility), robustness as well as accuracy of the method have been evaluated. Linearity of response was satisfactory for the two range concentrations available on the TDA AAS equipment, between approximately 25.0 and 200.0 μg kg(-1) (square regression) and 250.0 and 2000.0 μg kg(-1) (linear regression) of mercury. The residues for both ranges were homoscedastic and independent, with normal distribution. Correlation coefficients obtained for these ranges were higher than 0.995. Limits of quantification (LOQ) and of detection of the method (LDM), based on signal standard deviation (SD) for a low-in-mercury sample, were 3.0 and 1.0 μg kg(-1), respectively. Repeatability of the method was better than 4%. Within-laboratory reproducibility achieved a relative SD better than 6%. Robustness of the current method was evaluated and pointed sample mass as a significant factor. Accuracy (assessed as the analyte recovery) was calculated on basis of the repeatability, and ranged from 89% to 99%. The obtained results showed the suitability of the present method for direct mercury measurement in fresh fish and shrimp samples and the importance of monitoring the analysis conditions for food control purposes. Additionally, the competence of this method was recognized by accreditation under the standard ISO/IEC 17025.

  16. Improved microwave-assisted wet digestion procedures for accurate Se determination in fish and shellfish by flow injection-hydride generation-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lavilla, I.; Gonzalez-Costas, J.M.; Bendicho, C.

    2007-01-01

    Accurate determination of Se in biological samples, especially fish and shellfish, by hydride generation techniques has generally proven troublesome owing to the presence of organoselenium that cannot readily converted into inorganic selenium under usual oxidising conditions. Further improvements in the oxidation procedures are needed so as to obtain accurate concentration values when this type of samples is analyzed. Microwave-assisted wet digestion (MAWD) procedures of seafood based on HNO 3 or the mixture HNO 3 /H 2 O 2 and further thermal reduction of the Se(VI) formed to Se(IV) were evaluated. These procedures were as follows: (I) without H 2 O 2 and without heating to dryness; (II) without H 2 O 2 and with heating to dryness; (III) with H 2 O 2 and without heating to dryness; (IV) with H 2 O 2 and with heating to dryness. In general, low recoveries of selenium are obtained for several marine species (e.g., crustaceans and cephalopods), which may be ascribed to the presence of Se forms mainly associated with nonpolar proteins and lipids. Post-digestion UV irradiation proved very efficient since not only complete organoselenium decomposition was achieved but also the final step required for prereduction of Se(VI) into Se(IV) (i.e. heating at 90 deg. C for 30 min in 6 M HCl) could be avoided. With the MAWD/UV procedure, the use of strong oxidising agents (persuphate, etc.) or acids (e.g. perchloric acid) which are typically applied prior to Se determination by hydride generation techniques is overcome, and as a result, sample pre-treatment is significantly simplified. The method was successfully validated against CRM DOLT-2 (dogfish liver), CRM DORM-2 (dogfish muscle) and CRM TORT-2 (lobster hepatopancreas). Automated ultrasonic slurry sampling with electrothermal atomic absorption spectrometry was also applied for comparison. Total Se contents in ten seafood samples were established. Se levels ranged from 0.7 to 2.9 μg g -1

  17. Metal interferences and their removal prior to the determination of As(T) and As(III) in acid mine waters by hydride generation atomic absorption spectrometry

    Science.gov (United States)

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Ball, James W.

    2003-01-01

    Hydride generation atomic absorption spectrometry (HGAAS) is a sensitive and selective method for the determination of total arsenic (arsenic(III) plus arsenic(V)) and arsenic(III); however, it is subject to metal interferences for acid mine waters. Sodium borohydride is used to produce arsine gas, but high metal concentrations can suppress arsine production. This report investigates interferences of sixteen metal species including aluminum, antimony(III), antimony(V), cadmium, chromium(III), chromium(IV), cobalt, copper(II), iron(III), iron(II), lead, manganese, nickel, selenium(IV), selenium(VI), and zinc ranging in concentration from 0 to 1,000 milligrams per liter and offers a method for removing interfering metal cations with cation exchange resin. The degree of interference for each metal without cation-exchange on the determination of total arsenic and arsenic(III) was evaluated by spiking synthetic samples containing arsenic(III) and arsenic(V) with the potential interfering metal. Total arsenic recoveries ranged from 92 to 102 percent for all metals tested except antimony(III) and antimony(V) which suppressed arsine formation when the antimony(III)/total arsenic molar ratio exceeded 4 or the antimony(V)/total arsenic molar ratio exceeded 2. Arsenic(III) recoveries for samples spiked with aluminum, chromium(III), cobalt, iron(II), lead, manganese, nickel, selenium(VI), and zinc ranged from 84 to 107 percent over the entire concentration range tested. Low arsenic(III) recoveries occurred when the molar ratios of metals to arsenic(III) were copper greater than 120, iron(III) greater than 70, chromium(VI) greater than 2, cadmium greater than 800, antimony(III) greater than 3, antimony(V) greater than 12, or selenium(IV) greater than 1. Low recoveries result when interfering metals compete for available sodium borohydride, causing incomplete arsine production, or when the interfering metal oxidizes arsenic(III). Separation of interfering metal cations using

  18. Lead determination at ng/mL level by flame atomic absorption spectrometry using a tantalum coated slotted quartz tube atom trap.

    Science.gov (United States)

    Demirtaş, İlknur; Bakırdere, Sezgin; Ataman, O Yavuz

    2015-06-01

    Flame atomic absorption spectrometry (FAAS) still keeps its importance despite the relatively low sensitivity; because it is a simple and economical technique for determination of metals. In recent years, atom traps have been developed to increase the sensitivity of FAAS. Although the detection limit of FAAS is only at the level of µg/mL, with the use of atom traps it can reach to ng/mL. Slotted quartz tube (SQT) is one of the atom traps used to improve sensitivity. In atom trapping mode of SQT, analyte is trapped on-line in SQT for few minutes using ordinary sample aspiration, followed by the introduction of a small volume of organic solvent to effect the revolatilization and atomization of analyte species resulting in a transient signal. This system is economical, commercially available and easy to use. In this study, a sensitive analytical method was developed for the determination of lead with the help of SQT atom trapping flame atomization (SQT-AT-FAAS). 574 Fold sensitivity enhancement was obtained at a sample suction rate of 3.9 mL/min for 5.0 min trapping period with respect to FAAS. Organic solvent was selected as 40 µL of methyl isobutyl ketone (MIBK). To obtain a further sensitivity enhancement inner surface of SQT was coated with several transition metals. The best sensitivity enhancement, 1650 fold enhancement, was obtained by the Ta-coated SQT-AT-FAAS. In addition, chemical nature of Pb species trapped on quartz and Ta surface, and the chemical nature of Ta on quartz surface were investigated by X-ray photoelectron spectroscopy (XPS) and Raman Spectroscopy. Raman spectrometric results indicate that tantalum is coated on SQT surface in the form of Ta2O5. XPS studies revealed that the oxidation state of Pb in species trapped on both bare and Ta coated SQT surfaces is +2. For the accuracy check, the analyses of standard reference material were performed by use of SCP SCIENCE EnviroMAT Low (EU-L-2) and results for Pb were to be in good agreement with

  19. Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry.

    Science.gov (United States)

    do Lago, Ayla Campos; Marchioni, Camila; Mendes, Tássia Venga; Wisniewski, Célio; Fadini, Pedro Sergio; Luccas, Pedro Orival

    2016-11-01

    This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L -1 and buffer concentration of 0.01 mol L -1 , were adopted. The proposed method showed a linear response in the range of 0.081-10.0 μg L -1 , limits detection and quantification of 0.024 and 0.081 μg L -1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min -1 , and frequency of readings equal to 26 readings h -1 The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg -1 ), black tea (1.09 ± 0.15 μg kg -1 ), green tea (3.85 ± 0.13 μg kg -1 ), cigarette tobacco (38.27 ± 0.22 μg kg -1 ), and hair (0.35 ± 0.02 μg kg -1 ). © The Author(s) 2016.

  20. A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry.

    Science.gov (United States)

    Daşbaşı, Teslima; Saçmacı, Şerife; Ülgen, Ahmet; Kartal, Şenol

    2015-05-01

    A relatively rapid, accurate and precise solid phase extraction method is presented for the determination of cadmium(II) and lead(II) in various food and water samples. Quantitation is carried out by flame atomic absorption spectrometry (FAAS). The method is based on the retention of the trace metal ions on Dowex Marathon C, a strong acid cation exchange resin. Some important parameters affecting the analytical performance of the method such as pH, flow rate and volume of the sample solution; type, concentration, volume, flow rate of the eluent; and matrix effects on the retention of the metal ions were investigated. Common coexisting ions did not interfere on the separation and determination of the analytes. The detection limits (3 σb) for Cd(II) and Pb(II) were found as 0.13 and 0.18 μg L(-1), respectively, while the limit of quantification values (10 σb) were computed as 0.43 and 0.60 μg L(-1) for the same sequence of the analytes. The precision (as relative standard deviation was lower than 4% at 5 μg L(-1) Cd(II) and 10 μg L(-1) Pb(II) levels, and the preconcentration factor was found to be 250. The accuracy of the proposed procedure was verified by analysing the certified reference materials, SPS-WW2 Batch 108 wastewater level 2 and INCT-TL-1 tea leaves, with the satisfactory results. In addition, for the accuracy of the method the recovery studies (⩾ 95%) were carried out. The method was applied to the determination of the analytes in the various natural waters (lake water, tap water, waste water with boric acid, waste water with H2SO4) and food samples (pomegranate flower, organic pear, radish leaf, lamb meat, etc.), and good results were obtained. While the food samples almost do not contain cadmium, they have included lead at low levels of 0.13-1.12 μg g(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Selenium speciation using capillary electrophoresis coupled with modified electrothermal atomic absorption spectrometry after selective extraction with 5-sulfosalicylic acid functionalized magnetic nanoparticles.

    Science.gov (United States)

    Yan, Lizhen; Deng, Biyang; Shen, Caiying; Long, Chanjuan; Deng, Qiufen; Tao, Chunyao

    2015-05-22

    A new method for selenium speciation in fermented bean curd wastewater and juice was described. This method involved sample extraction with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), capillary electrophoresis (CE) separation, and online detection with a modified electrothermal atomic absorption spectrometry (ETAAS) system. The modified interface for ETAAS allowed for the introduction of CE effluent directly through the end of the graphite tube. Elimination of the upper injection hole of the graphite tube reduced the loss of the anlayte and enhanced the detection sensitivity. The SSA-SMNPs were synthesized and used to extract trace amounts of selenite [Se(IV)], selenite [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from dilute samples. The concentration enrichment factors for Se(VI), Se(IV), SeMet, and SeCys2 were 21, 29, 18, and 12, respectively, using the SSA-SMNPs extraction. The limits of detection for Se(VI), Se(IV), SeMet, and SeCys2 were 0.18, 0.17, 0.54, 0.49ngmL(-1), respectively. The RSD values (n=6) of method for intraday were observed between 0.7% and 2.9%. The RSD values of method for interday were less than 3.5%. The linear range of Se(VI) and Se(IV) were in the range of 0.5-200ngmL(-1), and the linear ranges of SeMet and SeCys2 were 2-500 and 2-1000ngmL(-1), respectively. The detection limits of this method were improved by 10 times due to the enrichment by the SSA-SMNP extraction. The contents of Se(VI) and Se(IV) in fermented bean curd wastewater were measured as 3.83 and 2.62ngmL(-1), respectively. The contents of Se(VI), Se(IV), SeMet, and SeCys2 in fermented bean curd juice were determined as 6.39, 4.08, 2.77, and 4.00ngmL(-1), respectively. The recoveries were in the range of 99.14-104.5% and the RSDs (n=6) of recoveries between 0.82% and 3.5%. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Determination of sub-ng g-1 levels of total inorganic arsenic and selenium in foods by hydride-generation atomic absorption spectrometry after pre-concentration.

    Science.gov (United States)

    Altunay, Nail; Gürkan, Ramazan

    2017-03-01

    A new and simple ultrasonic-assisted extraction (UAE) procedure was developed for the determination of inorganic arsenic and selenium in foods by hydride-generation atomic absorption spectrometry (HG-AAS). The various analytical variables affecting complex formation and extraction efficiency were investigated and optimised. The method is based on selective complex formation of As(III) and Se(IV) in the presence of excess As(V) and Se(VI) with toluidine red in the presence of tartaric acid at pH 4.5, and then extraction of the resulting condensation products into the micellar phase of non-ionic surfactant, polyethylene glycol dodecyl ether, Brij 35. Under optimised conditions, good linear relationships were obtained in the ranges of 4-225 and 12-400 ng l - 1 with limits of detection of 1.1 and 3.5 ng l - 1 for As(III) and Se(IV), respectively. The repeatability was better than 3.9% for both analytes (n = 10, 25 ng l - 1 ) while reproducibility ranged from 4.2% to 4.8%. The recoveries of As(III) and Se(IV) spiked at 25-100 ng l - 1 were in the range of 94.2-104.8%. After pre-concentration of a 5.0 ml sample, the sensitivity enhancement factors for As(III) and Se(IV) were 185 and 140, respectively. Accuracy was assessed by analysis of two standard reference materials (SRMs) and spiked recovery experiments. The method was successfully applied to the accurate and reliable determination of total As and total Se by HG-AAS after pre-reduction with a mixture of L-cysteine and tartaric acid. Finally, the method was shown to be rapid and sensitive, with good results for extraction, pre-concentration and determination of total As and Se contents (as As(III) and Se(IV)) from food samples.

  3. Development of mixed-waste analysis capability for graphite furnace atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Bass, D.A.; TenKate, L.B.; Wroblewski, A.

    1995-03-01

    Graphite furnace atomic absorption spectrophotometer (GFAAS) are typically configured with ventilation to capture potentially toxic and corrosive gases emitted from the vaporization of sample aliquots. When radioactive elements are present, additional concerns (such as meeting safety guidelines and ALARA principles) must be addressed. This report describes a modification to a GFAAS that provides additional containment of vaporized sample aliquots. The modification was found to increase containment by a factor of 80, given expected operating conditions. The use of the modification allows more mixed-waste samples to be analyzed, permits higher levels of radioactive samples to be analyzed, or exposes the analyst to less airborne radioactivity. The containment apparatus was attached to a Perkin-Elmer Zeeman 5000 spectrophotometer for analysis of mixed-waste samples; however, it could also be used on other systems and in other applications where greater containment of vaporized material is desired

  4. Determination of Ultra-Trace Amounts of Selenium(IV) by Flow Injection Hydride Generation Atomic Absorption Spectrometry with On-line Preconcentration by Co-precipitation with Lanthanium Hydroxide. Part II. On-line Addition of Coprecipating Agent

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Sloth, Jens Jørgen; Hansen, Elo Harald

    1996-01-01

    A flow injection procedure for the determination of ultra-trace amounts of selenium(IV) is described, which combines hydride generation atomic absorption spectrometry (HGAAS) with on-line preconcentration of the analyte by co-precipitation-dissolution in a filterless knotted Microline reactor...... with hydrochloric acid, allowing an ensuing determination via hydride generation. At different sample flow rates, i.e., 4.8, 6.4 and 8.8 ml/min, enrichment factors of 30, 40 and 46, respectively, were obtained at a sampling frequency of 33 samples/h. The detection limit (3s) was 0.005 µg/l at a sample flow rate...

  5. Simultaneous determination of Cd and Fe in beans and soil of different regions of Brazil using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling.

    Science.gov (United States)

    dos Santos, Lisia M G; Welz, Bernhard; Araujo, Rennan G O; Jacob, Silvana do C; Vale, Maria Goreti R; Martens, Andreas; Gonzaga Martens, Irland B; Becker-Ross, Helmut

    2009-11-11

    A fast routine screening method for the simultaneous determination of cadmium and iron in bean and soil samples is proposed, using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling. The primary absorption line at 228.802 nm has been used for the determination of cadmium, and an adjacent secondary line, at 228.726 nm, for iron. Fourteen bean samples and 10 soil samples from nine states all over Brazil have been analyzed. The limits of detection (3 sigma, n = 10) were 2.0 microg kg(-1) for Cd and 4.5 mg kg(-1) for Fe. The relative standard deviation ranged from 4 to 7% for Cd and from 5 to 28% for Fe, which is usually acceptable for a screening method. The accuracy of the method has been confirmed by the analysis of two certified reference materials; the results were in agreement with the certified values at a 95% confidence interval.

  6. Marine sediments monitoring studies for trace elements with the application of fast temperature programs and solid sampling high resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Orani, Anna Maria; Han, Eunmi; Mandjukov, Petko; Vassileva, Emilia

    2015-01-01

    Analytical procedure for the determination of As, Cd, Cu, Ni, Co and Cr in marine sediment samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS AAS) and direct solid sample analysis has been developed. The application of fast programs in combination with direct solid sampling allows to eliminate the drying and pretreatment steps, however makes impossible the use of liquid standards for calibration. Iridium treated platforms were applied throughout the present study. Calibration technique based on the use of solid certified reference materials (marine sediments) similar to the nature of the analyzed sample and statistics of regression analysis were applied to the real sediment samples. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signals. The ISO-17025 requirements and Eurachem guidelines were followed in the validation of the proposed analytical procedure. Accordingly, blanks, selectivity, calibration, linearity, working range, trueness, repeatability reproducibility, limits of detection and quantification and expanded uncertainty (k = 2) for all investigated elements were assessed. Two different approaches for the estimation of measurement uncertainty were applied and obtained results compared. The major contributors to the combined uncertainty of the analyte mass fraction were found to be the homogeneity of the samples and the microbalance precision. The influence of sample particle sizes on the total combined uncertainty was also evaluated. Traceability to SI system of units of the obtained by the proposed analytical procedure results was demonstrated. Additionally, validation of the methodology developed was effectuated by the comparison of the obtained results with independent method e.g. ICP-MS with external calibration. The use of solid sampling HR CS AAS for the determination of trace elements in marine sediment matrix gives significant advantages

  7. Sequential injection on-line matrix removal and trace metal preconcentration using a PTFE beads packed column as demonstrated for the determination of cadmium by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    A sequential injection (SI) on-line matrix removal and trace metal preconcentration procedure by using a novel microcolumn packed with PTFE beads is described, and demonstrated for trace cadmium analysis with detection by electrothermal atomic absorption spectrometry (ETAAS). The analyte is initi......A sequential injection (SI) on-line matrix removal and trace metal preconcentration procedure by using a novel microcolumn packed with PTFE beads is described, and demonstrated for trace cadmium analysis with detection by electrothermal atomic absorption spectrometry (ETAAS). The analyte...... is initially complexed with diethyldithiophosphate (DDPA) and adsorbed onto the column, which is afterwards eluted with 50 mul of ethanol and subsequently introduced via air segmentation into the graphite tube for quantification. The ETAAS determination is synchronized with sample pre-treatment in the SI....../h, quantitative adsorption of cadmium (99% retention efficiency) and an enrichment factor of 59.4 were obtained, as compared with only 46.7% and 28.0 by using a knotted reactor of similar internal surface area as the packed column. The detection limits and precision (RSD, 0.1 mug/l Cd) are at the same levels, i...

  8. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the Intern