WorldWideScience

Sample records for absorption liquid temperature

  1. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes

    2010-01-01

    Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...... processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures...

  2. Absorption and oxidation of no in ionic liquids

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns the absorption and in situ oxidation of nitric oxide (NO) in the presence of water and oxygen in ionic liquid compositions at ambient temperature.......The present invention concerns the absorption and in situ oxidation of nitric oxide (NO) in the presence of water and oxygen in ionic liquid compositions at ambient temperature....

  3. Reactor for tracking catalyst nanoparticles in liquid at high temperature under a high-pressure gas phase with X-ray absorption spectroscopy.

    Science.gov (United States)

    Nguyen, Luan; Tao, Franklin Feng

    2018-02-01

    Structure of catalyst nanoparticles dispersed in liquid phase at high temperature under gas phase of reactant(s) at higher pressure (≥5 bars) is important for fundamental understanding of catalytic reactions performed on these catalyst nanoparticles. Most structural characterizations of a catalyst performing catalysis in liquid at high temperature under gas phase at high pressure were performed in an ex situ condition in terms of characterizations before or after catalysis since, from technical point of view, access to the catalyst nanoparticles during catalysis in liquid phase at high temperature under high pressure reactant gas is challenging. Here we designed a reactor which allows us to perform structural characterization using X-ray absorption spectroscopy including X-ray absorption near edge structure spectroscopy and extended X-ray absorption fine structure spectroscopy to study catalyst nanoparticles under harsh catalysis conditions in terms of liquid up to 350 °C under gas phase with a pressure up to 50 bars. This reactor remains nanoparticles of a catalyst homogeneously dispersed in liquid during catalysis and X-ray absorption spectroscopy characterization.

  4. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues

    International Nuclear Information System (INIS)

    Groessle, Robin

    2015-01-01

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  5. Combined physical and chemical absorption of carbon dioxide in a mixture of ionic liquids

    International Nuclear Information System (INIS)

    Pinto, Alicia M.; Rodríguez, Héctor; Arce, Alberto; Soto, Ana

    2014-01-01

    Highlights: • Carbon dioxide can be absorbed in mixtures of two ionic liquids: [C 2 mim][EtSO 4 ] and [C 2 mim][OAc]. • A combination of physical and chemical absorption mechanisms is observed. • The CO 2 absorption capacity of the mixture of ionic liquids decreases with increasing temperature. • [C 2 mim][EtSO 4 ] in the mixture prevents solidification of the product resulting from reaction of [C 2 mim][OAc] and CO 2 . • Density and viscosity studies of the mixture of ionic liquids also lead to synergies, in particular at low temperatures. - Abstract: Ionic liquids have attracted great interest recently as the basis of a potential alternative technology for the capture of carbon dioxide. Beyond the inherent tunability of properties of individual ionic liquids, a further strategy in optimising the ionic liquid sorbent for this application is the use of mixtures of ‘pure’ ionic liquids. Some ionic liquids absorb CO 2 physically, whereas others do so chemically. Both mechanisms of absorption present advantages and disadvantages for a CO 2 capture process operating in a continuous regime. In this work, a mixture of 1-ethyl-3-methylimidazolium acetate (an ionic liquid that reacts chemically with CO 2 ) and 1-ethyl-3-methylimidazolium ethylsulfate (an ionic liquid that absorbs CO 2 only through a physical mechanism) was investigated for the absorption of CO 2 as a function of temperature and at pressures up to 17 bar. The absorption/desorption studies were complemented by the characterisation of thermal and physical properties of the mixture of ionic liquids, which provide extra information on the interactions at a molecular level, and are also critical for the assessment of its suitability for a proposed process and for the subsequent process design

  6. Development of an Ionic-Liquid Absorption Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, Don

    2011-03-29

    Solar Fueled Products (SFP) is developing an innovative ionic-liquid absorption heat pump (ILAHP). The development of an ILAHP is extremely significant, as it could result in annual savings of more than 190 billion kW h of electrical energy and $19 billion. This absorption cooler uses about 75 percent less electricity than conventional cooling and heating units. The ILAHP also has significant environmental sustainability benefits, due to reduced CO2 emissions. Phase I established the feasibility and showed the economic viability of an ILAHP with these key accomplishments: • Used the breakthrough capabilities provided by ionic liquids which overcome the key difficulties of the common absorption coolers. • Showed that the theoretical thermodynamic performance of an ILAHP is similar to existing absorption-cooling systems. • Established that the half-effect absorption cycle reduces the peak generator temperature, improving collector efficiency and reducing collector area. • Component testing demonstrated that the most critical components, absorber and generator, operate well with conventional heat exchangers. • Showed the economic viability of an ILAHP. The significant energy savings, sustainability benefits, and economic viability are compelling reasons to continue the ILAHP development.

  7. Spectroscopic study of low-temperature hydrogen absorption in palladium

    Energy Technology Data Exchange (ETDEWEB)

    Ienaga, K., E-mail: ienaga@issp.u-tokyo.ac.jp; Takata, H.; Onishi, Y.; Inagaki, Y.; Kawae, T. [Department of Applied Quantum Physics, Faculty of Engineering, Kyushu University, Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan); Tsujii, H. [Department of Physics, Faculty of Education, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Kimura, T. [Department of Physics, Kyushu University, Hakozaki, Higashi-Ku, Fukuoka 812-8581 (Japan)

    2015-01-12

    We report real-time detection of hydrogen (H) absorption in metallic palladium (Pd) nano-contacts immersed in liquid H{sub 2} using inelastic electron spectroscopy (IES). After introduction of liquid H{sub 2}, the spectra exhibit the time evolution from the pure Pd to the Pd hydride, indicating that H atoms are absorbed in Pd nano-contacts even at the temperature where the thermal process is not expected. The IES time and bias voltage dependences show that H absorption develops by applying bias voltage 30 ∼ 50 mV, which can be explained by quantum tunneling. The results represent that IES is a powerful method to study the kinetics of high density H on solid surface.

  8. Ionic liquid ultrasound assisted dispersive liquid-liquid microextraction method for preconcentration of trace amounts of rhodium prior to flame atomic absorption spectrometry determination

    Energy Technology Data Exchange (ETDEWEB)

    Molaakbari, Elaheh [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Young Research Society, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Mostafavi, Ali, E-mail: mostafavi.ali@gmail.com [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Afzali, Daryoush [Environment and Nanochemistry Department, Research Institute of Environmental Science, International Center for Science, High Technology and Environmental Science, Kerman (Iran, Islamic Republic of); Mineral Industries Research Center, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2011-01-30

    In this article, we consider ionic liquid based ultrasound-assisted dispersive liquid-liquid microextraction of trace amounts of rhodium from aqueous samples and show that this is a fast and reliable sample pre-treatment for the determination of rhodium ions by flame atomic absorption spectrometry. The Rh(III) was transferred into its complex with 2-(5-bromo-2-pyridylazo)-5-diethylamino phenol as a chelating agent, and an ultrasonic bath with the ionic liquid, 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide at room temperature was used to extract the analyte. The centrifuged rhodium complex was then enriched in the form of ionic liquid droplets and prior to its analysis by flame atomic absorption spectrometry, 300 {mu}L ethanol was added to the ionic liquid-rich phase. Finally, the influence of various parameters on the recovery of Rh(III) was optimized. Under optimum conditions, the calibration graph was linear in the range of 4.0-500.0 ng mL{sup -1}, the detection limit was 0.37 ng mL{sup -1} (3S{sub b}/m, n = 7) and the relative standard deviation was {+-}1.63% (n = 7, C = 200 ng mL{sup -1}). The results show that ionic liquid based ultrasound assisted dispersive liquid-liquid microextraction, combined with flame atomic absorption spectrometry, is a rapid, simple, sensitive and efficient analytical method for the separation and determination of trace amounts of Rh(III) ions with minimum organic solvent consumption.

  9. Passive Temperature Stabilization of Silicon Photonic Devices Using Liquid Crystals

    Directory of Open Access Journals (Sweden)

    Joanna Ptasinski

    2014-03-01

    Full Text Available In this work we explore the negative thermo-optic properties of liquid crystal claddings for passive temperature stabilization of silicon photonic integrated circuits. Photonic circuits are playing an increasing role in communications and computing, but they suffer from temperature dependent performance variation. Most existing techniques aimed at compensation of thermal effects rely on power hungry Joule heating. We show that integrating a liquid crystal cladding helps to minimize the effects of a temperature dependent drift. The advantage of liquid crystals lies in their high negative thermo-optic coefficients in addition to low absorption at the infrared wavelengths.

  10. A three-color absorption/scattering imaging technique for simultaneous measurements on distributions of temperature and fuel concentration in a spray

    Science.gov (United States)

    Qi, Wenyuan; Zhang, Yuyin

    2018-04-01

    A three-color imaging technique was proposed for simultaneous measurements on distributions of fuel/air mixture temperature and fuel vapor/liquid concentrations in evaporating sprays. The idea is based on that the vapor concentration is proportional to the absorption of vapor to UV light, the liquid-phase concentration is related to the light extinction due to scattering of droplet to visible light, and the mixture temperature can be correlated to the absorbance ratio at two absorbing wavelengths or narrow bands. For verifying the imaging system, the molar absorption coefficients of p-xylene at the three narrow bands, which were centered respectively at 265, 289, and 532 nm with FWHM of 10 nm, were measured in a specially designed calibration chamber at different temperatures (423-606 K) and pressure of 3.6 bar. It was found that the ratio of the molar absorption coefficients of p-xylene at the two narrow bands centered at the two UV wavelengths is sensitive to the mixture temperature. On the other hand, the distributions of fuel vapor/liquid concentrations can be obtained by use of absorbance due to ultraviolet absorption of vapor and visible light scattering of droplets. Combining these two methods, a simultaneous measurement on distributions of mixture temperature and fuel vapor/liquid concentrations can be realized. In addition, the temperature field obtained from the ratio of the two absorbing narrow bands can be further used to improve the measurement accuracy of vapor/liquid concentrations, because the absorption coefficients depend on temperature. This diagnostic was applied to an evaporating spray inside a high-temperature and high-pressure constant volume chamber.

  11. Kinetics of iron redox reactions in silicate liquids: A high-temperature X-ray absorption and Raman spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Magnien, V. [Physique des Mineraux et Magmas, CNRS-IPGP, 4 place Jussieu, 75252 Paris cedex 05 (France); CEA VALRHO Marcoule, SCDV, LEBV, BP 17171, 30207 Bagnols/Ceze (France); Neuville, D.R. [Physique des Mineraux et Magmas, CNRS-IPGP, 4 place Jussieu, 75252 Paris cedex 05 (France)]. E-mail: neuville@ipgp.jussieu.fr; Cormier, L. [IMPMC, CNRS UMR 7590, Universites Paris 6 and 7 and IPGP, 4 place Jussieu, 75252 Paris cedex 05 (France); Roux, J. [Physique des Mineraux et Magmas, CNRS-IPGP, 4 place Jussieu, 75252 Paris cedex 05 (France); Hazemann, J.-L. [Laboratoire de cristallographie, UPR 5031, CNRS, 38043 Grenoble (France); Pinet, O. [CEA VALRHO Marcoule, SCDV, LEBV, BP 17171, 30207 Bagnols/Ceze (France); Richet, P. [Physique des Mineraux et Magmas, CNRS-IPGP, 4 place Jussieu, 75252 Paris cedex 05 (France)

    2006-06-30

    The oxidation kinetics of a Fe-bearing supercooled liquid of the system SiO{sub 2}-CaO-MgO-Na{sub 2}O-FeO has been determined near the glass transition range by X-ray absorption near edge structure (XANES) and Raman spectroscopies. Both techniques yield room-temperature iron redox ratios in accord with wet chemical, Moessbauer and electron microprobe analyses. Similar oxidation kinetics have also been observed with both methods. At constant temperature, the kinetics obey an exponential law with a characteristic time that follows an Arrhenian temperature dependence. As redox changes are too fast to be accounted for in terms of diffusion of either ionic or molecular oxygen, these results lend further support to the idea that the rate-limiting factor for oxidation near the glass transition is diffusion of network-modifying cations along with a flux of electron holes.

  12. Room temperature ionic liquids enhanced the speciation of Cr(VI) and Cr(III) by hollow fiber liquid phase microextraction combined with flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Chujie, E-mail: cjzeng@126.com [Department of Chemistry and Material, Yulin Normal College, Yulin, Guangxi 537000 (China); Lin, Yao; Zhou, Neng; Zheng, Jiaoting; Zhang, Wei [Department of Chemistry and Material, Yulin Normal College, Yulin, Guangxi 537000 (China)

    2012-10-30

    Highlights: Black-Right-Pointing-Pointer First reported enhancement effect of RTILs in HF-LPME for the speciation of chromium. Black-Right-Pointing-Pointer The addition of RTILs led to 3.5 times improvement of the sensitivity of Cr(VI). Black-Right-Pointing-Pointer The proposed method is a simplicity, sensitivity, low cost, green method. - Abstract: A new method for the speciation of Cr(VI) and Cr(III) based on enhancement effect of room temperature ionic liquids (RTILs) for hollow fiber liquid phase microextraction (HF-LPME) combined with flame atomic absorption spectrometry (FAAS) was developed. Room temperature ionic liquids (RTILs) and diethyldithiocarbamate (DDTC) were used enhancement reagents and chelating reagent, respectively. The addition of room temperature ionic liquids led to 3.5 times improvement in the determination of Cr(VI). In this method, Cr(VI) reacts with DDTC yielding a hydrophobic complex, which is subsequently extracted into the lumen of hollow fiber, whereas Cr(III) is remained in aqueous solutions. The extraction organic phase was injected into FAAS for the determination of Cr(VI). Total Cr concentration was determined after oxidizing Cr(III) to Cr(VI) in the presence of KMnO{sub 4} and using the extraction procedure mentioned above. Cr(III) was calculated by subtracting of Cr(VI) from the total Cr. Under optimized conditions, a detection limit of 0.7 ng mL{sup -1} and an enrichment factor of 175 were achieved. The relative standard deviation (RSD) was 4.9% for Cr(VI) (40 ng mL{sup -1}, n = 5). The proposed method was successfully applied to the speciation of chromium in natural water samples with satisfactory results.

  13. Room temperature ionic liquids enhanced the speciation of Cr(VI) and Cr(III) by hollow fiber liquid phase microextraction combined with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Zeng, Chujie; Lin, Yao; Zhou, Neng; Zheng, Jiaoting; Zhang, Wei

    2012-01-01

    Highlights: ► First reported enhancement effect of RTILs in HF-LPME for the speciation of chromium. ► The addition of RTILs led to 3.5 times improvement of the sensitivity of Cr(VI). ► The proposed method is a simplicity, sensitivity, low cost, green method. - Abstract: A new method for the speciation of Cr(VI) and Cr(III) based on enhancement effect of room temperature ionic liquids (RTILs) for hollow fiber liquid phase microextraction (HF-LPME) combined with flame atomic absorption spectrometry (FAAS) was developed. Room temperature ionic liquids (RTILs) and diethyldithiocarbamate (DDTC) were used enhancement reagents and chelating reagent, respectively. The addition of room temperature ionic liquids led to 3.5 times improvement in the determination of Cr(VI). In this method, Cr(VI) reacts with DDTC yielding a hydrophobic complex, which is subsequently extracted into the lumen of hollow fiber, whereas Cr(III) is remained in aqueous solutions. The extraction organic phase was injected into FAAS for the determination of Cr(VI). Total Cr concentration was determined after oxidizing Cr(III) to Cr(VI) in the presence of KMnO 4 and using the extraction procedure mentioned above. Cr(III) was calculated by subtracting of Cr(VI) from the total Cr. Under optimized conditions, a detection limit of 0.7 ng mL −1 and an enrichment factor of 175 were achieved. The relative standard deviation (RSD) was 4.9% for Cr(VI) (40 ng mL −1 , n = 5). The proposed method was successfully applied to the speciation of chromium in natural water samples with satisfactory results.

  14. The Relationship Between Dynamics and Structure in the Far Infrared Absorption Spectrum of Liquid Water

    Energy Technology Data Exchange (ETDEWEB)

    Woods, K.

    2005-01-14

    Using an intense source of far-infrared radiation, the absorption spectrum of liquid water is measured at a temperature ranging from 269 to 323 K. In the infrared spectrum we observe modes that are related to the local structure of liquid water. Here we present a FIR measured spectrum that is sensitive to the low frequency (< 100cm{sup -1}) microscopic details that exist in liquid water.

  15. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues; Das TApIR Experiment IR-Absorptionsspektren fluessiger Wasserstoffisotopologe

    Energy Technology Data Exchange (ETDEWEB)

    Groessle, Robin

    2015-11-27

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  16. Energy absorption behaviors of nanoporous materials functionalized (NMF) liquids

    OpenAIRE

    Kim, Tae Wan

    2011-01-01

    For many decades, people have been actively investigating high-performance energy absorption materials, so as to develop lightweight and small-sized protective and damping devices, such as blast mitigation helmets, vehicle armors, etc. Recently, the high energy absorption efficiency of nanoporous materials functionalized (NMF) liquids has drawn considerable attention. A NMF liquid is usually a liquid suspension of nanoporous particles with large nanopore surface areas (100 - 2,000 m²/g). The ...

  17. Effect of nanoclay on thermal, mechanical and liquid absorption properties of epoxy-clay nanocomposite

    International Nuclear Information System (INIS)

    Nguyen Cong Quyen; Nguyen Pham Duy Linh; Bui Chuong; Doan Thi Yen Oanh

    2015-01-01

    Composite materials based on epoxy DER 331 hot cured by MHHPA with several contents of nanoclay I28E were prepared and characterized by TEM and SEM. Results showed that the nanostructures were created in two levels: intercalated structure and nanoparticles (cluster). The interaction between nanoclay and epoxy matrix was evaluated by properties such as: liquid absorption, TGA and DMA. It was shown that nanostructures of cluster, as well as the hydrophobic behavior of material with the presence of nanoclay have dominant effect to liquid absorption. Otherwise, the thermal stability was affected mainly by intercalation structure. Results of DMA showed that the interaction of epoxy-clay was strongly destroyed at the temperature higher than material Tg. (author)

  18. Effect of temperature on the valency bands of HDO in water in the liquid and solid states. Effects on the analysis of heavy water using infra-red absorption; Effet de temperature sur les bandes de valence de HDO dans l'eau a l'etat liquide et a l'etat solide - consequences pour l'analyse de l'eau lourde par absorption infra-rouge

    Energy Technology Data Exchange (ETDEWEB)

    Ceccaldi, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    After, a description of the technique used, a qualitative examination is made of the influence of the temperature on the {nu}{sub OH}(3,400 cm{sup -1}) and {nu}{sub OD} (2,500 cm{sup -1}) valence bands of HDO in the liquid state and then during the passage to the solid state. Quantitative examination with two cells of different thickness makes it possible to define the influence of temperature on the residual absorption of the pure liquid (D{sub 2}O or H{sub 2}O and on the valency bands ({nu}{sub OH} and {nu}{sub OD} respectively). It is found that a similar change occurs in the two bands but that the changes in the background are very different. During the passage from the liquid to the solid state the shape of the bands varies considerably but little change occurs in the total intensity. It has been possible to express these results in a simple form which is directly applicable to analytical problems. (authors) [French] Apres un rappel de la technique utilisee, on examine qualitativement l'influence de la temperature sur les bandes de valence {nu}{sub OH} (3400 cm{sup -1}) et {nu}{sub OD} (2500 cm{sup -1}) de HDO a l'etat liquide puis le passage a l'etat solide. L'examen quantitatif, avec deux cuves d'epaisseurs differentes, permet de preciser l'influence de la temperature sur l'absorption residuelle du liquide pur (D{sub 2}O ou H{sub 2}O) et sur les bandes de valence ( {nu}{sub OH} et {nu}{sub OD} respectivement). On constate une evolution parallele de ces bandes mais un comportement tres different du fond continu. Lors du passage de l'etat liquide a l'etat solide, la forme des bandes varie considerablement mais non l'intensite totale. On a pu formuler ces resultats sous une forme simple applicable directement aux problemes analytiques. (auteurs)

  19. Theoretical and experimental investigation of the thermodynamic and kinetic nitrogen absorption by liquid alloys

    Energy Technology Data Exchange (ETDEWEB)

    Grigorenko, G.M.; Pomarin, Yu.M.; Orlovsky, V.Yu. [Natsional' na Akademyiya Nauk Ukrayini, Kiev (Ukraine). E.O. Paton Inst. of Electrical Welding

    1999-07-01

    The work was performed within the framework of the Ukrainian-French program of cooperation in the field of metal of high inclusion and was dedicated to joint fundamental investigation of thermodynamics and kinetics of nitrogen absorption by the Ni-20%Cr liquid alloy. The comparative investigations of kinetic absorption of nitrogen from the gas phase were performed by the method of levitation melting within the temperature range of 1600-1800 C in the atmosphere of pure nitrogen. Using the method of mathematical statistics and experimental Cp values at the different temperatures, the temperature dependence of the equilibrium constant of nitrogen solution reaction in the Ni-20%Cr alloy was obtained (lgK{sub N}=1284/T-1.94). Theoretical and graphical analysis of the experimental data allowed to make the conclusion that the absorption nitrogen process is controlled by the general kinetic equation of the first degree. Using of the aforementioned results the mass transfer factors were calculated with the different temperature and were obtained their mathematical description ({beta}{sub N}{sup Ni-Cr}=-454/T+0.285). (orig.)

  20. Soft X-ray Absorption Spectroscopy of Liquids and Solutions.

    Science.gov (United States)

    Smith, Jacob W; Saykally, Richard J

    2017-12-13

    X-ray absorption spectroscopy (XAS) is an electronic absorption technique for which the initial state is a deeply buried core level. The photon energies corresponding to such transitions are governed primarily by the binding energies of the initial state. Because the binding energies of core electrons vary significantly among atomic species, this makes XAS an element-selective spectroscopy. Proper interpretation of XA spectra can provide detailed information on the local chemical and geometric environment of the target atom. The introduction of liquid microjet and flow cell technologies into XAS experiments has enabled the general study of liquid samples. Liquids studied to date include water, alcohols, and solutions with relevance to biology and energy technology. This Review summarizes the experimental techniques employed in XAS studies of liquid samples and computational methods used for interpretation of the resulting spectra and summarizes salient experiments and results obtained in the XAS investigations of liquids.

  1. Ab initio calculation of the electronic absorption spectrum of liquid water

    International Nuclear Information System (INIS)

    Martiniano, Hugo F. M. C.; Galamba, Nuno; Cabral, Benedito J. Costa

    2014-01-01

    The electronic absorption spectrum of liquid water was investigated by coupling a one-body energy decomposition scheme to configurations generated by classical and Born-Oppenheimer Molecular Dynamics (BOMD). A Frenkel exciton Hamiltonian formalism was adopted and the excitation energies in the liquid phase were calculated with the equation of motion coupled cluster with single and double excitations method. Molecular dynamics configurations were generated by different approaches. Classical MD were carried out with the TIP4P-Ew and AMOEBA force fields. The BLYP and BLYP-D3 exchange-correlation functionals were used in BOMD. Theoretical and experimental results for the electronic absorption spectrum of liquid water are in good agreement. Emphasis is placed on the relationship between the structure of liquid water predicted by the different models and the electronic absorption spectrum. The theoretical gas to liquid phase blue-shift of the peak positions of the electronic absorption spectrum is in good agreement with experiment. The overall shift is determined by a competition between the O–H stretching of the water monomer in liquid water that leads to a red-shift and polarization effects that induce a blue-shift. The results illustrate the importance of coupling many-body energy decomposition schemes to molecular dynamics configurations to carry out ab initio calculations of the electronic properties in liquid phase

  2. Study of absorption and re-emission processes in a ternary liquid scintillation system

    International Nuclear Information System (INIS)

    Xiao Hualin; Wang Naiyan; Li Xiaobo; Cao Jun; Wen Liangjian; Zheng Dong

    2010-01-01

    Liquid scintillators are widely used as the neutrino target in neutrino experiments. The absorption and emission of different components of a ternary liquid scintillator (Linear Alkyl Benzene (LAB) as the solvent, 2, 5-diphenyloxazole (PPO) as the fluor and p-bis-(o-methylstyryl)-benzene (bis-MSB) as wavelength shifter) are studied. It is shown that the absorption of this liquid scintillator is dominant by LAB and PPO at wavelengths less than 349 nm, and the absorption by bis-MSB becomes prevalent at the wavelength larger than 349 nm. The fluorescence quantum yields, which are the key parameters to model the absorption and re-emission processes in large liquid scintillation detectors, are measured. (authors)

  3. Transdermal nicotine absorption handling e-cigarette refill liquids.

    Science.gov (United States)

    Maina, Giovanni; Castagnoli, Carlotta; Passini, Valter; Crosera, Matteo; Adami, Gianpiero; Mauro, Marcella; Filon, Francesca Larese

    2016-02-01

    The concentrated nicotine in e-cigarette refill liquids can be toxic if inadvertently ingested or absorbed through the skin. Reports of poisonings due to accidental ingestion of nicotine on refill liquids are rapidly increasing, while the evaluation of nicotine dermally absorbed still lacks. For that reason we studied transdermal nicotine absorption after the skin contamination with e-liquid. Donor chambers of eight Franz diffusion cells were filled with 1 mL of 0.8 mg/mL nicotine e-liquid for 24 h. The concentration of nicotine in the receiving phase was determined by high-performance liquid chromatography (LOD:0.1 μg/mL). Nicotine was detectable in receiving solution 2 h after the start of exposure and increased progressively. The medium flux calculated was 4.82 ± 1.05 μg/cm(2)/h with a lag time of 3.9 ± 0.1 h. After 24 h, the nicotine concentration in the receiving compartment was 101.02 ± 22.35 μg/cm(2) corresponding to 3.04 mg of absorbed nicotine after contamination of a skin surface of 100 cm(2). Skin contamination with e-liquid can cause nicotine skin absorption: caution must be paid when handling refill e-liquids. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Young; Park, Seong Ryong; Baik, Young Jin; Chang, Ki Chang; Ra, Ho Sang; Kim, Min Sung [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Kim, Yong Chan [Korea University, Seoul (Korea, Republic of)

    2011-12-15

    This research concerns the development of a compression/absorption high-temperature hybrid heat pump that uses a natural refrigerant mixture. Heat pumps based on the compression/absorption cycle offer various advantages over conventional heat pumps based on the vapor compression cycle, such as large temperature glide, temperature lift, flexible operating range, and capacity control. In this study, a lab-scale prototype hybrid heat pump was constructed with a two-stage compressor, absorber, desorber, desuperheater, solution heat exchanger, solution pump, liquid/vapor separator, and rectifier as the main components. The hybrid heat pump system operated at 10-kW-class heating capacity producing hot water whose temperature was more than 90 .deg. C when the heat source and sink temperatures were 50 .deg. C. Experiments with various NH{sub 3}/H{sub 2}O mass fractions and compressor/pump circulation ratios were performed on the system. From the study, the system performance was optimized at a specific NH{sub 3} concentration.

  5. A new cell for temperature-dependent X-ray absorption spectroscopy of liquid solutions: application to PbBr2 solutions in diethylene glycol.

    Science.gov (United States)

    Lützenkirchen-Hecht, D; Oldag, T; Keil, P; Keller, H L; Frahm, R

    2005-03-01

    An in situ cell has been constructed for temperature-dependent X-ray absorption experiments (EXAFS and XANES) of lead bromine (PbBr2) solutions in diethylene glycol in the temperature range from room temperature up to about 433 K. The solution is kept in a thermostated container made of carbon-reinforced teflon between two thin chemically inert quartz glass windows with a high transmission for hard X-rays. The construction of the cell ensures that these X-ray windows are thermalized so that any possible precipitation of solid products from the solution is inhibited. The cell consists mainly of two hermetically sealed teflon containers for the thermostating fluid (silicon oil) that were fitted together in such a way that a small and variable volume (approximately 2-4 cm3) for the liquid under investigation was achieved. A small thermocouple in a glass enclosure was placed in the solution to maintain temperature control and feedback to the thermostat. The cell design and its performance for temperature-dependent in situ investigations with X-rays are reported. Some preliminary results obtained for PbBr2 solutions in diethylene glycol are given.

  6. High temperature measurement of water vapor absorption

    Science.gov (United States)

    Keefer, Dennis; Lewis, J. W. L.; Eskridge, Richard

    1985-01-01

    An investigation was undertaken to measure the absorption coefficient, at a wavelength of 10.6 microns, for mixtures of water vapor and a diluent gas at high temperature and pressure. The experimental concept was to create the desired conditions of temperature and pressure in a laser absorption wave, similar to that which would be created in a laser propulsion system. A simplified numerical model was developed to predict the characteristics of the absorption wave and to estimate the laser intensity threshold for initiation. A non-intrusive method for temperature measurement utilizing optical laser-beam deflection (OLD) and optical spark breakdown produced by an excimer laser, was thoroughly investigated and found suitable for the non-equilibrium conditions expected in the wave. Experiments were performed to verify the temperature measurement technique, to screen possible materials for surface initiation of the laser absorption wave and to attempt to initiate an absorption wave using the 1.5 kW carbon dioxide laser. The OLD technique was proven for air and for argon, but spark breakdown could not be produced in helium. It was not possible to initiate a laser absorption wave in mixtures of water and helium or water and argon using the 1.5 kW laser, a result which was consistent with the model prediction.

  7. A liquid-He cryostat for structural and thermal disorder studies by X-ray absorption.

    Science.gov (United States)

    Bouamrane, F; Ribbens, M; Fonda, E; Adjouri, C; Traverse, A

    2003-07-01

    A new device operating from 4.2 to 300 K is now installed on the hard X-ray station of the DCI ring in LURE in order to measure absorption coefficients. This liquid-He bath device has three optical windows. One allows the incident beam to impinge on the sample, one located at 180 degrees with respect to the sample allows transmitted beams to be detected, and another located at 90 degrees is used to detect emitted photons. Total electron yield detection mode is also possible thanks to a specific sample holder equipped with an electrode that collects the charges created by the emitted electrons in the He gas brought from the He bath around the sample. The performance of the cryostat is described by measurements of the absorption coefficients versus the temperature for Cu and Co foils. For comparison, the absorption coefficient is also measured for Cu clusters. As expected from dimension effects, the Debye temperature obtained for the clusters is lower than that of bulk Cu.

  8. Tunable UV-visible absorption of SnS2 layered quantum dots produced by liquid phase exfoliation.

    Science.gov (United States)

    Fu, Xiao; Ilanchezhiyan, P; Mohan Kumar, G; Cho, Hak Dong; Zhang, Lei; Chan, A Sattar; Lee, Dong J; Panin, Gennady N; Kang, Tae Won

    2017-02-02

    4H-SnS 2 layered crystals synthesized by a hydrothermal method were used to obtain via liquid phase exfoliation quantum dots (QDs), consisting of a single layer (SLQDs) or multiple layers (MLQDs). Systematic downshift of the peaks in the Raman spectra of crystals with a decrease in size was observed. The bandgap of layered QDs, estimated by UV-visible absorption spectroscopy and the tunneling current measurements using graphene probes, increases from 2.25 eV to 3.50 eV with decreasing size. 2-4 nm SLQDs, which are transparent in the visible region, show selective absorption and photosensitivity at wavelengths in the ultraviolet region of the spectrum while larger MLQDs (5-90 nm) exhibit a broad band absorption in the visible spectral region and the photoresponse under white light. The results show that the layered quantum dots obtained by liquid phase exfoliation exhibit well-controlled and regulated bandgap absorption in a wide tunable wavelength range. These novel layered quantum dots prepared using an inexpensive method of exfoliation and deposition from solution onto various substrates at room temperature can be used to create highly efficient visible-blind ultraviolet photodetectors and multiple bandgap solar cells.

  9. Tunable integration of absorption-membrane-adsorption for efficiently separating low boiling gas mixtures near normal temperature

    Science.gov (United States)

    Liu, Huang; Pan, Yong; Liu, Bei; Sun, Changyu; Guo, Ping; Gao, Xueteng; Yang, Lanying; Ma, Qinglan; Chen, Guangjin

    2016-01-01

    Separation of low boiling gas mixtures is widely concerned in process industries. Now their separations heavily rely upon energy-intensive cryogenic processes. Here, we report a pseudo-absorption process for separating low boiling gas mixtures near normal temperature. In this process, absorption-membrane-adsorption is integrated by suspending suitable porous ZIF material in suitable solvent and forming selectively permeable liquid membrane around ZIF particles. Green solvents like water and glycol were used to form ZIF-8 slurry and tune the permeability of liquid membrane surrounding ZIF-8 particles. We found glycol molecules form tighter membrane while water molecules form looser membrane because of the hydrophobicity of ZIF-8. When using mixing solvents composed of glycol and water, the permeability of liquid membrane becomes tunable. It is shown that ZIF-8/water slurry always manifests remarkable higher separation selectivity than solid ZIF-8 and it could be tuned to further enhance the capture of light hydrocarbons by adding suitable quantity of glycol to water. Because of its lower viscosity and higher sorption/desorption rate, tunable ZIF-8/water-glycol slurry could be readily used as liquid absorbent to separate different kinds of low boiling gas mixtures by applying a multistage separation process in one traditional absorption tower, especially for the capture of light hydrocarbons. PMID:26892255

  10. Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometry.

    Science.gov (United States)

    Martinis, Estefanía M; Bertón, Paula; Olsina, Roberto A; Altamirano, Jorgelina C; Wuilloud, Rodolfo G

    2009-08-15

    A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)mim][PF(6)]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 microl of 9.0 mol L(-1) hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3ngL(-1) and the relative standard deviation (RSD) for 10 replicates at 1 microg L(-1) Hg(2+) was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).

  11. Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Martinis, Estefania M.; Berton, Paula; Olsina, Roberto A.; Altamirano, Jorgelina C.; Wuilloud, Rodolfo G.

    2009-01-01

    A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C 4 mim][PF 6 ]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 μl of 9.0 mol L -1 hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3 ng L -1 and the relative standard deviation (RSD) for 10 replicates at 1 μg L -1 Hg 2+ was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).

  12. CL 14: Solvation structure and dynamics of room temperature ionic liquids

    International Nuclear Information System (INIS)

    Musat, Raluca M.; Polyansky, Dmitriy; Crowell, Robert A.; Thomas, Marie; Wishart, James F.; Takahashi, Kenji; Katsumura, Yosuke

    2010-01-01

    Room temperature ionic liquids (RTILs) have emerged as a new class of solvents that, due to their unique properties (e.g., low volatility, large electrochemical window, high conductivity, etc.), have several potential applications. Among these are their possible use in nuclear fuel reprocessing, dye sensitized solar cells, and CO 2 sequestration. The properties of a given class of RTILs depend strongly on the choice of the counter anion. In this contribution we present new results using both static and time-resolved EXAFS (ca. 1 ns resolution) and time resolved optical absorption spectroscopy on a series of bromide containing imidazolium salts. The static results provide detailed information of the solvation shell of the bromide ion while the time-resolved data shed light on the nature and chemical behavior of the lowest lying charge transfer band, the physical motion of the bromine atom and its conversion to di-bromide. The photochemistry of the charge transfer (CT) band of the room temperature ionic liquid 1-hexyl-3-methylimidazolium bromide is investigated using ultrafast transient absorption spectroscopy (TA) in the near-IR and steady state UV absorption. Irradiation of the CT band at 266 nm results in the steady state production of di-bromide which absorbs strongly at 266 nm. It is shown that this photoproduct, which is apparently very stable, adversely affects ultrafast transient absorption measurements. Flowing and simultaneously translating the sample mitigates this effect and reveals new transient species and dynamics within the detection window of 850 nm to 1250 nm. (authors)

  13. Ab initio molecular dynamics study of temperature and pressure-dependent infrared dielectric functions of liquid methanol

    Directory of Open Access Journals (Sweden)

    C. C. Wang

    2017-03-01

    Full Text Available The temperature and pressure-dependent dielectric functions of liquids are of great importance to the thermal radiation transfer and the diagnosis and control of fuel combustion. In this work, we apply the state-of-the-art ab initio molecular dynamics (AIMD method to calculate the infrared dielectric functions of liquid methanol at 183–573 K and 0.1–160 MPa in the spectral range 10−4000 cm−1, and study the temperature and pressure effects on the dielectric functions. The AIMD approach is validated by the Infrared Variable Angle Spectroscopic Ellipsometry (IR-VASE experimental measurements at 298 K and 0.1 MPa, and the proposed IR-VASE method is verified by comparison with paper data of distilled water. The results of the AIMD approach agrees well with the experimental values of IR-VASE. The experimental and theoretical analyses indicate that the temperature and pressure exert a noticeable influence on the infrared dielectric functions of liquid methanol. As temperature increases, the average molecular dipole moment decreases. The amplitudes of dominant absorption peaks reduce to almost one half as temperature increases from 183 to 333 K at 0.1 MPa and from 273 to 573 K at 160 MPa. The absorption peaks below 1500 cm–1 show a redshift, while those centered around 3200 cm–1 show a blueshift. Moreover, larger average dipole moments are observed as pressure increases. The amplitudes of dominant absorption peaks increase to almost two times as pressure increases from 1 to 160 MPa at 373 K.

  14. Porosity and liquid absorption of cement paste

    DEFF Research Database (Denmark)

    Krus, M.; Hansen, Kurt Kielsgaard; Kunzel, H. M.

    1997-01-01

    be a slowing-down effect which is related to water because the absorption of organic liquids, such as hexane, is quite normal. Measurements of the porosity of hardened cement paste determined by helium pycnometry and water saturation show that water molecules can enter spaces in the microstructure which...... are not accessible to the smaller helium atoms. Considering the results of dilatation tests both before and after water and hexane saturation, it seems possible that a contraction of capillary pores due to moisture-related swelling of the cement gel leads to the non-linear water absorption over the square root...

  15. Density, ultrasound velocity, acoustic impedance, reflection and absorption coefficient determination of liquids via multiple reflection method.

    Science.gov (United States)

    Hoche, S; Hussein, M A; Becker, T

    2015-03-01

    The accuracy of density, reflection coefficient, and acoustic impedance determination via multiple reflection method was validated experimentally. The ternary system water-maltose-ethanol was used to execute a systematic, temperature dependent study over a wide range of densities and viscosities aiming an application as inline sensor in beverage industries. The validation results of the presented method and setup show root mean square errors of: 1.201E-3 g cm(-3) (±0.12%) density, 0.515E-3 (0.15%) reflection coefficient and 1.851E+3 kg s(-1) m(-2) (0.12%) specific acoustic impedance. The results of the diffraction corrected absorption showed an average standard deviation of only 0.12%. It was found that the absorption change shows a good correlation to concentration variations and may be useful for laboratory analysis of sufficiently pure liquids. The main part of the observed errors can be explained by the observed noise, temperature variation and the low signal resolution of 50 MHz. In particular, the poor signal-to-noise ratio of the second reflector echo was found to be a main accuracy limitation. Concerning the investigation of liquids the unstable properties of the reference material PMMA, due to hygroscopicity, were identified to be an additional, unpredictable source of uncertainty. While dimensional changes can be considered by adequate methodology, the impact of the time and temperature dependent water absorption on relevant reference properties like the buffer's sound velocity and density could not be considered and may explain part of the observed deviations. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Thermodynamic properties of CO2 absorption in hydroxyl ammonium ionic liquids at pressures of (100-1600) kPa

    International Nuclear Information System (INIS)

    Kurnia, K.A.; Harris, F.; Wilfred, C.D.; Abdul Mutalib, M.I.; Murugesan, T.

    2009-01-01

    Solubility of CO 2 in six hydroxyl ammonium ionic liquids 2-hydroxyethanaminium acetate [hea], bis(2-hydroxyethyl)ammonium acetate [bheaa], 2-hydroxy-N-(2-hydroxyethyl)-N-methylethanaminium acetate [hhemea], 2-hydroxyethanaminium lactate [hel], bis(2-hydroxyethyl)ammonium lactate [bheal], 2-hydroxy-N-(2-hydroxyethyl)-N-methylethanaminium lactate [hhemel] at temperatures (298.15, 313.15, and 328.16) K and pressures ranging from (100 to 1600) kPa was determined. From the experimental solubility data, the Henry's constant of CO 2 for each hydroxyl ammonium ionic liquids was estimated and reported as a function of temperature. Furthermore, enthalpy and entropy of absorption were obtained from estimated Henry's constant. The results showed that the solubility increase with increasing pressure and decrease with increasing temperature and the solubility of CO 2 in these six hydroxyl ammonium ionic liquids was in sequence: [hea] > [bheaa] > [hel] > [bheal] > [hhemel] > [hhemea].

  17. Temperature-dependent optical absorption of SrTiO3

    International Nuclear Information System (INIS)

    Kok, Dirk J.; Irmscher, Klaus; Naumann, Martin; Guguschev, Christo; Galazka, Zbigniew; Uecker, Reinhard

    2015-01-01

    The optical absorption edge and near infrared absorption of SrTiO 3 were measured at temperatures from 4 to 1703 K. The absorption edge decreases from 3.25 eV at 4 K to 1.8 eV at 1703 K and is extrapolated to approximately 1.2 eV at the melting point (2350 K). The transmission in the near IR decreases rapidly above 1400 K because of free carrier absorption and is about 50% of the room temperature value at 1673 K. The free carriers are generated by thermal excitation of electrons over the band gap and the formation of charged vacancies. The observed temperature-dependent infrared absorption can be well reproduced by a calculation based on simple models for the intrinsic free carrier concentration and the free carrier absorption coefficient. The measured red shift of the optical absorption edge and the rising free carrier absorption strongly narrow the spectral range of transmission and impede radiative heat transport through the crystal. These effects have to be considered in high temperature applications of SrTiO 3 -based devices, as the number of free carriers rises considerably, and in bulk crystal growth to avoid growth instabilities. Temperature dependent optical absorption edge of SrTiO 3 , measured, fitted, and extrapolated to the melting point. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Hydrogen Sulfide and Ionic Liquids: Absorption, Separation, and Oxidation.

    Science.gov (United States)

    Chiappe, Cinzia; Pomelli, Christian Silvio

    2017-06-01

    Economical and environmental concerns are the main motivations for development of energy-efficient processes and new eco-friendly materials for the capture of greenhouse gases. Currently, H 2 S capture is dominated by physical and/or chemical absorption technologies, which are, however, energy intensive and often problematic from an environmental point of view due to emission of volatile solvent components. Ionic liquids have been proposed as a promising alternative to conventional solvents because of their low volatility and other interesting properties. The aim of the present review paper is to provide a detailed overview of the achievements and difficulties that have been encountered in finding suitable ionic liquids for H 2 S capture. The effect of ionic liquid anions, cations, and functional groups on the H 2 S absorption, separation, and oxidation are highlighted. Recent developments on yet scarcely available molecular simulations and on the development of robust predictive methods are also discussed.

  19. Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Berton, Paula; Martinis, Estefanía M.; Martinez, Luis D.; Wuilloud, Rodolfo G.

    2012-01-01

    Highlights: ► Synergy of ultrasound energy and TILDLME technique for improved metal extraction. ► Highly selective determination of inorganic Co species at trace levels. ► Speciation analysis of Co in several nutritional supplements with highly complex matrices. ► Development of an environmentally friendly microextraction technique with minimal waste production and sample consumption. - Abstract: In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C 6 mim][PF 6 ] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4 ng L −1 , while the relative standard deviation (RSD) was 4.7% (at 0.5 μg L −1 Co level and n = 10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.

  20. Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Berton, Paula; Martinis, Estefania M. [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN-CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Martinez, Luis D. [INQUISAL-CONICET, Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, San Luis (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@mendoza-conicet.gob.ar [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN-CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2012-02-03

    Highlights: Black-Right-Pointing-Pointer Synergy of ultrasound energy and TILDLME technique for improved metal extraction. Black-Right-Pointing-Pointer Highly selective determination of inorganic Co species at trace levels. Black-Right-Pointing-Pointer Speciation analysis of Co in several nutritional supplements with highly complex matrices. Black-Right-Pointing-Pointer Development of an environmentally friendly microextraction technique with minimal waste production and sample consumption. - Abstract: In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C{sub 6}mim][PF{sub 6}] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4 ng L{sup -1}, while the relative standard deviation (RSD) was 4.7% (at 0.5 {mu}g L{sup -1} Co level and n = 10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.

  1. Selective Reversible Absorption of the Industrial Off-Gas Components CO2 and NOx by Ionic Liquids

    DEFF Research Database (Denmark)

    Kaas-Larsen, Peter Kjartan; Thomassen, P.; Schill, Leonhard

    2016-01-01

    Ionic liquids are promising new materials for climate and pollution control by selective absorption of CO2 and NOx in industrial off-gases. In addition practical cleaning of industrial off gases seems to be attractive by use of ionic liquids distributed on the surface of porous, high surface area...... carriers in the form of so-called Supported Ionic Liquid Phase (SILP) materials. The potential of selected ionic liquids for absorption of CO2 and NOx are demonstrated and the possible interference of other gases influencing the stability and absorption capacity of the ionic liquids are investigated...

  2. The use of infrared absorption to determine density of liquid hydrogen.

    Science.gov (United States)

    Unland, H. D.; Timmerhaus, K. D.; Kropschot, R. H.

    1972-01-01

    Experimental evaluation of the use of infrared absorption for determining the density of liquid hydrogen, and discussion of the feasibility of an airborne densitometer based on this concept. The results indicate that infrared absorption of liquid hydrogen is highly sensitive to the density of hydrogen, and, under the operating limitations of the equipment and experimental techniques used, the determined values proved to be repeatable to an accuracy of 2.7%. The desiderata and limitations of an in-flight density-determining device are outlined, and some of the feasibility problems are defined.

  3. Thermodynamic analysis of an absorption refrigeration system with ionic-liquid/refrigerant mixture as a working fluid

    International Nuclear Information System (INIS)

    Kim, Yoon Jo; Kim, Sarah; Joshi, Yogendra K.; Fedorov, Andrei G.; Kohl, Paul A.

    2012-01-01

    Thermodynamics of an ionic-liquid (IL) based absorption refrigeration system has been numerically analyzed. It provides an alternative to the normally toxic working fluids, such as the ammonia in conventional absorption systems. The use of ILs also eliminates crystallization and metal-compatibility problems of the water/LiBr system. Mixtures of refrigerants and imidazolium-based ILs are theoretically explored as the working fluid pairs in a miniature absorption refrigeration system, so as to utilize waste-heat to power a refrigeration/heat pump system for electronics cooling. A non-random two-liquid (NRTL) model was built and used to predict the solubility of the mixtures. Saturation temperatures at the evaporator and condenser were set at 25 °C and 50 °C, respectively, with the power dissipation of 100 W. Water in combination with [emim][BF 4 ] (1-ethyl-3-methylimidazolium tetrafluoroborate) gave the highest coefficient of performance (COP) around 0.9. The refrigerant/IL compatibility indicated by the circulation ratio, alkyl chain length of the IL, and thermodynamic properties of the refrigerants, such as latent heat of evaporation were proven to be important factors in determining the performance of the absorption system. The negative effect of high viscosity was mitigated by dilution of the IL with the refrigerant and the use of slightly larger microfluidic channel heat exchangers. -- Highlights: ► Mixtures of refrigerant/ionic-liquid are studied for absorption system. ► We carry out comprehensive theoretical thermodynamic analysis. ► The essential factors of refrigerant/IL affecting the performance are identified. ► Water/[emim][BF 4 ] showed the best performance of COP. ► The effects of high viscosity ILs on the system performance are not significant.

  4. Absorption and oxidation of nitrogen oxide in ionic liquids

    DEFF Research Database (Denmark)

    Kunov-Kruse, Andreas Jonas; Thomassen, Peter Langelund; Riisager, Anders

    2016-01-01

    A new strategy for capturing nitrogen oxide, NO, from the gas phase is presented. Dilute NO gas is removed from the gas phase by ionic liquids under ambient conditions. The nitrate anion of the ionic liquid catalyzes the oxidation of NO to nitric acid by atmospheric oxygen in the presence of water....... The nitric acid is absorbed in the ionic liquid up to approximately one mole HNO3 per mole of the ionic liquid due to the formation of hydrogen bonds. The nitric acid can be desorbed by heating, thereby regenerating the ionic liquid with excellent reproducibility. Here, time-resolved in-situ spectroscopic...... investigations of the reaction and products are presented. The procedure reveals a new vision for removing the pollutant NO by absorption into a non-volatile liquid and converting it into a useful bulk chemical, that is, HNO3....

  5. On the development of high temperature ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    Ammonia-water hybrid absorption-compression heat pumps (HACHP) are a promising technology for development of ecient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure...... limits may be possible to exceed if needed for actual applications. Feasible heat supply temperatures using these component limits are investigated. A feasible solution is defined as one that satisfies constraints on the COP, low and high pressure, compressor discharge temperature, vapour water content...... and volumetric heat capacity. The ammonia mass fraction and the liquid circulation ratio both influence these constraining parameters. The paper investigates feasible combinations of these parameters through the use of a numerical model. 28 bar components allow temperatures up to 111 °C, 50 bar up to 129°C...

  6. Absorption Refrigeration Cycles with Ammonia-Ionic Liquid Working Pairs Studied by Molecular Simulation.

    Science.gov (United States)

    Becker, Tim M; Wang, Meng; Kabra, Abhishek; Jamali, Seyed Hossein; Ramdin, Mahinder; Dubbeldam, David; Infante Ferreira, Carlos A; Vlugt, Thijs J H

    2018-04-18

    For absorption refrigeration, it has been shown that ionic liquids have the potential to replace conventional working pairs. Due to the huge number of possibilities, conducting lab experiments to find the optimal ionic liquid is infeasible. Here, we provide a proof-of-principle study of an alternative computational approach. The required thermodynamic properties, i.e., solubility, heat capacity, and heat of absorption, are determined via molecular simulations. These properties are used in a model of the absorption refrigeration cycle to estimate the circulation ratio and the coefficient of performance. We selected two ionic liquids as absorbents: [emim][Tf 2 N], and [emim][SCN]. As refrigerant NH 3 was chosen due to its favorable operating range. The results are compared to the traditional approach in which parameters of a thermodynamic model are fitted to reproduce experimental data. The work shows that simulations can be used to predict the required thermodynamic properties to estimate the performance of absorption refrigeration cycles. However, high-quality force fields are required to accurately predict the cycle performance.

  7. Absorption Refrigeration Cycles with Ammonia–Ionic Liquid Working Pairs Studied by Molecular Simulation

    Science.gov (United States)

    2018-01-01

    For absorption refrigeration, it has been shown that ionic liquids have the potential to replace conventional working pairs. Due to the huge number of possibilities, conducting lab experiments to find the optimal ionic liquid is infeasible. Here, we provide a proof-of-principle study of an alternative computational approach. The required thermodynamic properties, i.e., solubility, heat capacity, and heat of absorption, are determined via molecular simulations. These properties are used in a model of the absorption refrigeration cycle to estimate the circulation ratio and the coefficient of performance. We selected two ionic liquids as absorbents: [emim][Tf2N], and [emim][SCN]. As refrigerant NH3 was chosen due to its favorable operating range. The results are compared to the traditional approach in which parameters of a thermodynamic model are fitted to reproduce experimental data. The work shows that simulations can be used to predict the required thermodynamic properties to estimate the performance of absorption refrigeration cycles. However, high-quality force fields are required to accurately predict the cycle performance. PMID:29749996

  8. Temperature-insensitive laser frequency locking near absorption lines

    International Nuclear Information System (INIS)

    Kostinski, Natalie; Olsen, Ben A.; Marsland, Robert III; McGuyer, Bart H.; Happer, William

    2011-01-01

    Combined magnetically induced circular dichroism and Faraday rotation of an atomic vapor are used to develop a variant of the dichroic atomic vapor laser lock that eliminates lock sensitivity to temperature fluctuations of the cell. Operating conditions that eliminate first-order sensitivity to temperature fluctuations can be determined by low-frequency temperature modulation. This temperature-insensitive gyrotropic laser lock can be accurately understood with a simple model, that is in excellent agreement with observations in potassium vapor at laser frequencies in a 2 GHz range about the 770.1 nm absorption line. The methods can be readily adapted for other absorption lines.

  9. Structure and dynamics in liquid water from x-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Wernet, Philippe

    2009-01-01

    Oxygen K-edge x-ray absorption spectra of water are discussed. The spectra of gas-phase water, liquid water and ice illustrate the sensitivity of oxygen K-edge x-ray absorption spectroscopy to hydrogen bonding in water. Transmission mode spectra of amorphous and crystalline ice are compared to x-ray Raman spectra of ice. The good agreement consolidates the experimental spectrum of crystalline ice and represents an incentive for theoretical calculations of the oxygen K-edge absorption spectrum of crystalline ice. Time-resolved infrared-pump and x-ray absorption probe results are finally discussed in the light of this structural interpretation.

  10. Evaluation of ionic liquids as absorbents for ammonia absorption refrigeration cycles using COSMO-based process simulations

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, E.; Ferro, V.R., E-mail: victor.ferro@uam.es; Riva, J. de; Moreno, D.; Palomar, J.

    2014-06-01

    Highlights: • NH{sub 3}–IL absorption cycles are modeled by COSMO-based Aspen simulations. • Proposed a priori computational approach is validated using experimental data. • Cycle performance was analyzed for conventional and task-specific ILs. • IL solvents with high NH{sub 3} absorption capacity improve the cycle performance. • Using IL mixtures is revealed as promising alternative in NH{sub 3} absorption applications. - Abstract: COSMO-based process simulations with Aspen Plus/Aspen HYSYS are used, for the first time, to a priori estimate the thermodynamic performance of ammonia absorption refrigeration cycles using ionic liquids as absorbents. This allows not only broadening the criteria set used to select/design ionic liquids with optimized properties to be used in that role, but also evaluating innovative strategies to improve the cycle’s performances. COSMO-RS method provides the information required for both creating the ionic liquid non-database components and specifying the COSMOSAC property model to perform Aspen Plus calculations. The computational procedure used here gives at the same time reasonable good property predictions of the vapor (refrigerant) and the condensed (ammonia + ionic liquid) phases as well as physically consistent estimations of the cycle’s performance under different conditions. Current results agree with those previously reported in the literature for several ionic liquid-based systems taken for comparison. In addition, task-specific ionic liquids, with improved properties for ammonia absorption, and also binary ionic liquid mixtures are considered in the analysis. It is obtained that ionic liquids showing higher ammonia absorption capacity among the considered absorbents simultaneously provide the best cycle’s performances. The cycle performances vary in relatively wide intervals depending on the ammonia concentration in the (refrigerant + absorbent) solutions. This behavior is strongly modulated by the ammonia

  11. Evaluation of ionic liquids as absorbents for ammonia absorption refrigeration cycles using COSMO-based process simulations

    International Nuclear Information System (INIS)

    Ruiz, E.; Ferro, V.R.; Riva, J. de; Moreno, D.; Palomar, J.

    2014-01-01

    Highlights: • NH 3 –IL absorption cycles are modeled by COSMO-based Aspen simulations. • Proposed a priori computational approach is validated using experimental data. • Cycle performance was analyzed for conventional and task-specific ILs. • IL solvents with high NH 3 absorption capacity improve the cycle performance. • Using IL mixtures is revealed as promising alternative in NH 3 absorption applications. - Abstract: COSMO-based process simulations with Aspen Plus/Aspen HYSYS are used, for the first time, to a priori estimate the thermodynamic performance of ammonia absorption refrigeration cycles using ionic liquids as absorbents. This allows not only broadening the criteria set used to select/design ionic liquids with optimized properties to be used in that role, but also evaluating innovative strategies to improve the cycle’s performances. COSMO-RS method provides the information required for both creating the ionic liquid non-database components and specifying the COSMOSAC property model to perform Aspen Plus calculations. The computational procedure used here gives at the same time reasonable good property predictions of the vapor (refrigerant) and the condensed (ammonia + ionic liquid) phases as well as physically consistent estimations of the cycle’s performance under different conditions. Current results agree with those previously reported in the literature for several ionic liquid-based systems taken for comparison. In addition, task-specific ionic liquids, with improved properties for ammonia absorption, and also binary ionic liquid mixtures are considered in the analysis. It is obtained that ionic liquids showing higher ammonia absorption capacity among the considered absorbents simultaneously provide the best cycle’s performances. The cycle performances vary in relatively wide intervals depending on the ammonia concentration in the (refrigerant + absorbent) solutions. This behavior is strongly modulated by the ammonia absorption

  12. Magnetomotive room temperature dicationic ionic liquid: a new concept toward centrifuge-less dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Beiraghi, Asadollah; Shokri, Masood; Seidi, Shahram; Godajdar, Bijan Mombani

    2015-01-09

    A new centrifuge-less dispersive liquid-liquid microextraction technique based on application of magnetomotive room temperature dicationic ionic liquid followed by electrothermal atomic absorption spectrometry (ETAAS) was developed for preconcentration and determination of trace amount of gold and silver in water and ore samples, for the first time. Magnetic ionic liquids not only have the excellent properties of ionic liquids but also exhibit strong response to an external magnetic field. These properties provide more advantages and potential application prospects for magnetic ionic liquids than conventional ones in the fields of extraction processes. In this work, thio-Michler's ketone (TMK) was used as chelating agent to form Ag/Au-TMK complexes. Several important factors affecting extraction efficiency including extraction time, rate of vortex agitator, pH of sample solution, concentration of the chelating agent, volume of ionic liquid as well as effects of interfering species were investigated and optimized. Under the optimal conditions, the limits of detection (LOD) were 3.2 and 7.3ngL(-1) with the preconcentration factors of 245 and 240 for Au and Ag, respectively. The precision values (RSD%, n=7) were 5.3% and 5.8% at the concentration level of 0.05μgL(-1) for Au and Ag, respectively. The relative recoveries for the spiked samples were in the acceptable range of 96-104.5%. The results demonstrated that except Hg(2+), no remarkable interferences are created by other various ions in the determination of Au and Ag, so that the tolerance limits (WIon/WAu or Ag) of major cations and anions were in the range of 250-1000. The validated method was successfully applied for the analysis of Au and Ag in some water and ore samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Calculation of near-edge x-ray-absorption fine structure at finite temperatures: Spectral signatures of hydrogen bond breaking in liquid water

    International Nuclear Information System (INIS)

    Hetenyi, Balazs; De Angelis, Filippo; Giannozzi, Paolo; Car, Roberto

    2004-01-01

    We calculate the near-edge x-ray-absorption fine structure of H 2 O in the gas, hexagonal ice, and liquid phases using heuristic density-functional based methods. We present a detailed comparison of our results with experiment. The differences between the ice and water spectra can be rationalized in terms of the breaking of hydrogen bonds around the absorbing molecule. In particular the increase in the pre-edge absorption feature from ice to water is shown to be due to the breaking of a donor hydrogen bond. We also find that in water approximately 19% of hydrogen bonds are broken

  14. Electromagnetic-radiation absorption by water.

    Science.gov (United States)

    Lunkenheimer, P; Emmert, S; Gulich, R; Köhler, M; Wolf, M; Schwab, M; Loidl, A

    2017-12-01

    Why does a microwave oven work? How does biological tissue absorb electromagnetic radiation? Astonishingly, we do not have a definite answer to these simple questions because the microscopic processes governing the absorption of electromagnetic waves by water are largely unclarified. This absorption can be quantified by dielectric loss spectra, which reveal a huge peak at a frequency of the exciting electric field of about 20 GHz and a gradual tailing off toward higher frequencies. The microscopic interpretation of such spectra is highly controversial and various superpositions of relaxation and resonance processes ascribed to single-molecule or molecule-cluster motions have been proposed for their analysis. By combining dielectric, microwave, THz, and far-infrared spectroscopy, here we provide nearly continuous temperature-dependent broadband spectra of water. Moreover, we find that corresponding spectra for aqueous solutions reveal the same features as pure water. However, in contrast to the latter, crystallization in these solutions can be avoided by supercooling. As different spectral contributions tend to disentangle at low temperatures, this enables us to deconvolute them when approaching the glass transition under cooling. We find that the overall spectral development, including the 20 GHz feature (employed for microwave heating), closely resembles the behavior known for common supercooled liquids. Thus water's absorption of electromagnetic waves at room temperature is not unusual but very similar to that of glass-forming liquids at elevated temperatures, deep in the low-viscosity liquid regime, and should be interpreted along similar lines.

  15. Electromagnetic-radiation absorption by water

    Science.gov (United States)

    Lunkenheimer, P.; Emmert, S.; Gulich, R.; Köhler, M.; Wolf, M.; Schwab, M.; Loidl, A.

    2017-12-01

    Why does a microwave oven work? How does biological tissue absorb electromagnetic radiation? Astonishingly, we do not have a definite answer to these simple questions because the microscopic processes governing the absorption of electromagnetic waves by water are largely unclarified. This absorption can be quantified by dielectric loss spectra, which reveal a huge peak at a frequency of the exciting electric field of about 20 GHz and a gradual tailing off toward higher frequencies. The microscopic interpretation of such spectra is highly controversial and various superpositions of relaxation and resonance processes ascribed to single-molecule or molecule-cluster motions have been proposed for their analysis. By combining dielectric, microwave, THz, and far-infrared spectroscopy, here we provide nearly continuous temperature-dependent broadband spectra of water. Moreover, we find that corresponding spectra for aqueous solutions reveal the same features as pure water. However, in contrast to the latter, crystallization in these solutions can be avoided by supercooling. As different spectral contributions tend to disentangle at low temperatures, this enables us to deconvolute them when approaching the glass transition under cooling. We find that the overall spectral development, including the 20 GHz feature (employed for microwave heating), closely resembles the behavior known for common supercooled liquids. Thus water's absorption of electromagnetic waves at room temperature is not unusual but very similar to that of glass-forming liquids at elevated temperatures, deep in the low-viscosity liquid regime, and should be interpreted along similar lines.

  16. Temperature-dependent mid-IR absorption spectra of gaseous hydrocarbons

    International Nuclear Information System (INIS)

    Klingbeil, Adam E.; Jeffries, Jay B.; Hanson, Ronald K.

    2007-01-01

    Quantitative mid-IR absorption spectra (2500-3400 cm -1 ) for 12 pure hydrocarbon compounds are measured at temperatures ranging from 25 to 500 deg. C using an FTIR spectrometer. The hydrocarbons studied are n-pentane, n-heptane, n-dodecane, 2,2,4-trimethyl-pentane (iso-octane), 2-methyl-butane, 2-methyl-pentane, 2,4,4-trimethyl-1-pentene, 2-methyl-2-butene, propene, toluene, m-xylene, and ethylbenzene. Room-temperature measurements of neat hydrocarbon vapor were made with an instrument resolution of both 0.1 and 1 cm -1 (FWHM) to confirm that the high-resolution setting was required only to resolve the propene absorption spectrum while the spectra of the other hydrocarbons could be resolved with 1 cm -1 resolution. High-resolution (0.1 cm -1 ), room-temperature measurements of neat hydrocarbons were made at low pressure (∼1 Torr, 133 Pa) and compared to measurements of hydrocarbon/N 2 mixtures at atmospheric pressure to verify that no pressure broadening could be observed over this pressure range. The temperature was varied between 25 and 500 o C for atmospheric-pressure measurements of hydrocarbon/N 2 mixtures (X hydrocarbon ∼0.06-1.5%) and it was found that the absorption cross section shows simple temperature-dependent behavior for a fixed wavelength over this temperature range. Comparisons with previous FTIR data over a limited temperature range and with high-resolution laser absorption data over a wide temperature range show good agreement

  17. In situ gas temperature measurements by UV-absorption spectroscopy

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    2009-01-01

    The absorption spectrum of the NO A(2)Sigma(+) uniform and stable gas temperatures over a 0.533 m path....... The accuracy of both methods is discussed. Validation of the classical Lambert-Beer law has been demonstrated at NO concentrations up to 500 ppm and gas temperatures up to 1,500 degrees C over an optical absorption path length of 0.533 m....

  18. Nonlinear absorption of fullerene- and nanotubes-doped liquid crystal systems

    Czech Academy of Sciences Publication Activity Database

    Kamanina, N.; Reshak, Ali H; Vasiliev, P.Y.; Vangonen, A. I.; Studeonov, V. I.; Usanov, Y. E.; Ebothe, J.; Gondek, E.; Wojcik, W.; Danel, A.

    2009-01-01

    Roč. 41, č. 3 (2009), s. 391-394 ISSN 1386-9477 Institutional research plan: CEZ:AV0Z60870520 Keywords : nonlinear absorption properties * organic electrooptical systems * liquid crystal * fullerene s * nanotubes * PVK-derivatives Subject RIV: BO - Biophysics Impact factor: 1.177, year: 2009

  19. Dynamic Leidenfrost temperature on micro-textured surfaces: Acoustic wave absorption into thin vapor layer

    Science.gov (United States)

    Jerng, Dong Wook; Kim, Dong Eok

    2018-01-01

    The dynamic Leidenfrost phenomenon is governed by three types of pressure potentials induced via vapor hydrodynamics, liquid dynamic pressure, and the water hammer effect resulting from the generation of acoustic waves at the liquid-vapor interface. The prediction of the Leidenfrost temperature for a dynamic droplet needs quantitative evaluation and definition for each of the pressure fields. In particular, the textures on a heated surface can significantly affect the vapor hydrodynamics and the water hammer pressure. We present a quantitative model for evaluating the water hammer pressure on micro-textured surfaces taking into account the absorption of acoustic waves into the thin vapor layer. The model demonstrates that the strength of the acoustic flow into the liquid droplet, which directly contributes to the water hammer pressure, depends on the magnitude of the acoustic resistance (impedance) in the droplet and the vapor region. In consequence, the micro-textures of the surface and the increased spacing between them reduce the water hammer coefficient ( kh ) defined as the ratio of the acoustic flow into the droplet to total generated flow. Aided by numerical calculations that solve the laminar Navier-Stokes equation for the vapor flow, we also predict the dynamic Leidenfrost temperature on a micro-textured surface with reliable accuracy consistent with the experimental data.

  20. Low-Absorption Liquid Crystals for Infrared Beam Steering

    Science.gov (United States)

    2015-09-30

    controlled the curing temperature at 0oC to obtain small domain size and fast response time is expected. Here, a UV light-emitting diode ( LED ) lamp ...absorption; def.=deformation; w =weak absorption; v.=variable intensity) [B. D. Mistry, A Handbook of Spectroscopic Data: Chemistry- UV , IR, PMR, CNMR and...contributed by the core structure and terminal groups. Due to UV instability of double bonds and carbon-carbon triple bonds, conjugated phenyl rings have

  1. Performance analysis of absorption heat transformer cycles using ionic liquids based on imidazolium cation as absorbents with 2,2,2-trifluoroethanol as refrigerant

    International Nuclear Information System (INIS)

    Ayou, Dereje S.; Currás, Moisés R.; Salavera, Daniel; García, Josefa; Bruno, Joan C.; Coronas, Alberto

    2014-01-01

    Highlights: • TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) absorption heat transformer cycles are studied. • Influence of various operating conditions on cycle’s performance is investigated. • Performance comparisons with H 2 O + LiBr and TFE + TEGDME cycles are done. • Enthalpy data for TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) liquid mixtures are calculated. • TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) cycles have higher gross temperature lift (GTL). - Abstract: A detailed thermodynamic performance analysis of a single-stage absorption heat transformer and double absorption heat transformer cycles using new working pairs composed of ionic liquids (1-ethyl-3-methylimidazolium tetrafluoroborate ([emim][BF 4 ]) and 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF 4 ])) as absorbent and 2,2,2-trifluoroethanol (TFE) as refrigerant has been studied. Several performance indicators were used to evaluate and compare the performance of the cycles using the TFE + [emim][BF 4 ] and TFE + [bmim][BF 4 ] working pairs with the conventional H 2 O + LiBr and organic TFE + TEGDME working pairs. The obtained results show that the ionic liquid based working pairs are suitable candidates to replace the conventional H 2 O + LiBr working pairs in order to avoid the disadvantages associated with it mainly crystallization and corrosion and also they perform better (higher gross temperature lift) than TFE + TEGDME working pair at several operating conditions considered in this work

  2. Ultrasonic absorption and velocity dispersion of binary mixture liquid crystal MBBA/EBBA

    International Nuclear Information System (INIS)

    Choi, K.

    1979-01-01

    The effect of phase transitions and the partial magnetic alignment for liquid crystal molecules on the ultrasonic absorption and velocity dispersion has been investigated. The binary mixture of Shiff base liquid crystals MBBA/EBBA (55:45 mole %) showed anomalous ultrasonic absorption and velocity dispersion at eutectic (Tsub(m) = -20 0 C) and clearing point (Tsub(c) = 50 0 C) at the frequency range of 5 MHz, 10MHz, 15MHz and 30 MHz. The experimental data were analyzed in terms of relaxation time and Fixman theory. The anisotropy of the propagation velocity due to the magnetic alignment was about 0.9% (the deviation between velocities propagating parallel and perpendicular to the applied field). (author)

  3. Absorption Refrigeration Cycles with Ammonia-Ionic Liquid Working Pairs Studied by Molecular Simulation

    NARCIS (Netherlands)

    Becker, T.M.; Wang, M.; Kabra, Abhishek; Jamali, S.H.; Ramdin, M.; Dubbeldam, D.; Infante Ferreira, C.A.; Vlugt, T.J.H.

    2018-01-01

    For absorption refrigeration, it has been shown that ionic liquids have the potential to replace conventional working pairs. Due to the huge number of possibilities, conducting lab experiments to find the optimal ionic liquid is infeasible. Here, we provide a proof-of-principle study of an

  4. Effect of bile diversion on satiety and fat absorption from liquid and solid dietary sources

    International Nuclear Information System (INIS)

    Doty, J.E.; Gu, Y.G.; Meyer, J.H.

    1988-01-01

    In previous studies, liquid fat has been used to determine the effect of bile diversion on fat absorption. Since protein digests, in addition to bile salts, are capable of solubilizing lipids, we hypothesized that fat incorporated in the protein-rich matrix of solid food would be less sensitive to bile diversion than fat ingested as an oil or liquid. Using [3H]glycerol triether as a nonabsorbable fat recovery marker, we determined how much [14C]triolein was absorbed from solid (chicken liver) and liquid (margarine) dietary sources. After a standard liquid/solid meal with either the chicken liver or margarine labeled, midintestinal chyme was collected for 6 hr, extracted, and counted for 14C and 3H activity. Zero, eighty, or one hundred percent of endogenous bile was diverted. Fat absorption from both chicken liver and margarine was nearly complete by midintestine with 0% diversion and was little affected by diversion of 80% of bile. Complete biliary diversion significantly decreased fat absorption from margarine (87.9 +/- 4.4 to 37.2 +/- 9.2%, P less than 0.05) but reduced [14C]triolein absorption from chicken liver less consistently and insignificantly (78.8 +/- 6.9 to 43.9 +/- 10.6%). These data indicate that fat absorption is not solely dependent on bile and support the hypothesis that fat ingested in a cellular matrix is less dependent on bile than liquid fat. Using these same animals but with the midintestinal cannulas plugged to expose the distal intestine to unabsorbed luminal nutrients, we also demonstrated that bile diversion of an initial meal reduced food consumption at a meal offered 3 hr later

  5. Absorption solar cooling systems using optimal driving temperatures

    International Nuclear Information System (INIS)

    Lecuona, Antonio; Ventas, Rubén; Vereda, Ciro; López, Ricardo

    2015-01-01

    The optimum instantaneous driving temperature of a solar cooling facility is determined along a day. The chillers compared use single effect cycles working with NH 3 /LiNO 3 , either conventional or hybridised by incorporating a low pressure booster compressor. Their performances are compared with a H 2 O/LiBr single effect absorption chiller as part of the same solar system. The results of a detailed thermodynamic cycle for the absorption chillers allow synthesizing them in a modified characteristic temperature difference model. The day accumulated solar cold production is determined using this optimum temperature during two sunny days in mid-July and mid-September, located in Madrid, Spain. The work shows the influences of operational variables and a striking result: selection of a time-constant temperature during all the day does not necessarily imply a substantial loss, being the temperature chosen a key parameter. The results indicate that the NH 3 /LiNO 3 option with no boosting offers a smaller production above-zero Celsius degrees temperatures, but does not require higher hot water driving temperatures than H 2 O/LiBr. The boosted cycle offers superior performance. Some operational details are discussed. - Highlights: • Instantaneous optimum driving temperature t g,op for solar cooling in Madrid. • 3 absorption cycles tested: H 2 O/LiBr and NH 3 /LiNO 3 single effect and hybrid. • The t g,op of the hybrid cycle is 16 °C lower than both single effect cycles. • The best fixed driving temperature can reach almost the same behaviour than t g,op

  6. Distributed temperature sensor testing in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig, E-mail: cgerardi@anl.gov; Bremer, Nathan; Lisowski, Darius; Lomperski, Stephen

    2017-02-15

    Highlights: • Distributed temperature sensors measured high-resolution liquid-sodium temperatures. • DTSs worked well up to 400 °C. • A single DTS simultaneously detected sodium level and temperature. - Abstract: Rayleigh-backscatter-based distributed fiber optic sensors were immersed in sodium to obtain high-resolution liquid-sodium temperature measurements. Distributed temperature sensors (DTSs) functioned well up to 400 °C in a liquid sodium environment. The DTSs measured sodium column temperature and the temperature of a complex geometrical pattern that leveraged the flexibility of fiber optics. A single Ø 360 μm OD sensor registered dozens of temperatures along a length of over one meter at 100 Hz. We also demonstrated the capability to use a single DTS to simultaneously detect thermal interfaces (e.g. sodium level) and measure temperature.

  7. Temperature-dependent structure evolution in liquid gallium

    International Nuclear Information System (INIS)

    Xiong, L.H.; Wang, X.D.; Yu, Q.; Zhang, H.; Zhang, F.; Sun, Y.; Cao, Q.P.; Xie, H.L.; Xiao, T.Q.; Zhang, D.X.; Wang, C.Z.; Ho, K.M.

    2017-01-01

    Temperature-dependent atomistic structure evolution of liquid gallium (Ga) has been investigated by using in situ high energy X-ray diffraction experiment and ab initio molecular dynamics simulation. Both experimental and theoretical results reveal the existence of a liquid structural change around 1000 K in liquid Ga. Below and above this temperature the liquid exhibits differences in activation energy for self-diffusion, temperature-dependent heat capacity, coordination numbers, density, viscosity, electric resistivity and thermoelectric power, which are reflected from structural changes of the bond-orientational order parameter Q_6, fraction of covalent dimers, averaged string length and local atomic packing. This finding will trigger more studies on the liquid-to-liquid crossover in metallic melts. - Graphical abstract: Atomistic structure evolution of liquid gallium has been investigated by using in situ high energy X-ray diffraction and ab initio molecular dynamics simulations, which both demonstrate the existence of a liquid structural change together with reported density, viscosity, electric resistivity and absolute thermoelectric power data.

  8. Interferometer for Measuring Fast Changes of Refractive Index and Temperature in Transparent Liquids

    DEFF Research Database (Denmark)

    Miller, Arne; Hussmann, E. K.; McLaughlin, W. L.

    1975-01-01

    A double‐beam interferometer has been designed for detecting changes of refractive index in transparent liquids associated with the absorption of ionizing radiation energy, due to short electron beam pulses from an accelerator. The response time of the interferometer is less than 0.2 μsec......, and refractive index changes of the order of 10−7 can be measured, corresponding to a temperature change of ∼10−3  °C and an absorbed dose in water of ∼350 rad. The interferometer can be used as either a real‐time or integrating radiation dosimeter, if the temperature coefficient of the refractive index (dn...

  9. Prediction of refrigerant absorption and onset of natural convection in lubricant oil

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Jader R.; Marcelino Neto, Moises A. [Department of Mechanical Engineering, Federal University of Santa Catarina, Florianopolis, SC 88040900 (Brazil); Thoma, Stefan M. [Department of Mechanical and Process Engineering, Swiss Federal Institute of Technology, Sonneggstrasse 3, 8092 Zurich (Switzerland)

    2008-11-15

    Refrigerant absorption and mixing in lubricant oil are important in the design of refrigeration compressors and refrigeration systems. Experimental work is reported on absorption of R-134a vapour through the top interface of an initially stagnant layer of pure lubricant oil. Since the liquid refrigerant is heavier than the oil, mixing is enhanced due to natural mass convection. In the present paper, the behaviour of the liquid temperature during absorption is described based on measurements carried out in a test rig consisting of a transparent 70 mm ID, 150 mm long, vertical glass tube through which absorption can be directly observed. Transient liquid temperatures were measured at three different heights in the test section (two in the vapour, one in the liquid). The experimental work is complemented by a theoretical analysis of the critical time for the onset of mass transfer induced Rayleigh instability. The model is based on a critical mass transfer Rayleigh number criterion widely reported in the literature and takes into account the variation of physical properties in the liquid layer. The critical time for the onset of natural mass convection increases with decreasing system pressure as a result of a lower equilibrium concentration at the vapour-liquid interface. (author)

  10. Temperature-dependent absorption cross sections for hydrogen peroxide vapor

    Science.gov (United States)

    Nicovich, J. M.; Wine, P. H.

    1988-01-01

    Relative absorption cross sections for hydrogen peroxide vapor were measured over the temperature ranges 285-381 K for lambda = 230 nm-295 nm and 300-381 K for lambda = 193 nm-350 nm. The well established 298 K cross sections at 202.6 and 228.8 nm were used as an absolute calibration. A significant temperature dependence was observed at the important tropospheric photolysis wavelengths lambda over 300 nm. Measured cross sections were extrapolated to lower temperatures, using a simple model which attributes the observed temperature dependence to enhanced absorption by molecules possessing one quantum of O-O stretch vibrational excitation. Upper tropospheric photodissociation rates calculated using the extrapolated cross sections are about 25 percent lower than those calculated using currently recommended 298 K cross sections.

  11. Low Temperature Reduction of Alumina Using Fluorine Containing Ionic Liquids

    Energy Technology Data Exchange (ETDEWEB)

    Dr. R. G. Reddy

    2007-09-01

    phenomena involved in aluminum deposition on copper in AlCl3-BMIMCl electrolyte was found to be instantaneous followed by diffusion controlled three-dimensional growth of nuclei. Diffusion coefficient (Do) of the electroactive species Al2Cl7¯ ion was in the range from 6.5 to 3.9×10–7 cm2∙s–1 at a temperature of 30°C. Relatively little research efforts have been made toward the fundamental understanding and modeling of the species transport and transformation information involved in ionic liquid mixtures, which eventually could lead to quantification of electrochemical properties. Except that experimental work in this aspect usually is time consuming and expensive, certain characteristics of ionic liquids also made barriers for such analyses. Low vapor pressure and high viscosity make them not suitable for atomic absorption spectroscopic measurement. In addition, aluminum electrodeposition in ionic liquid electrolytes are considered to be governed by multi-component mass, heat and charge transport in laminar and turbulent flows that are often multi-phase due to the gas evolution at the electrodes. The kinetics of the electrochemical reactions is in general complex. Furthermore, the mass transfer boundary layer is about one order of magnitude smaller than the thermal and hydrodynamic boundary layer (Re=10,000). Other phenomena that frequently occur are side reactions and temperature or concentration driven natural convection. As a result of this complexity, quantitative knowledge of the local parameters (current densities, ion concentrations, electrical potential, temperature, etc.) is very difficult to obtain. This situation is a serious obstacle for improving the quality of products, efficiency of manufacturing and energy consumption. The gap between laboratory/batch scale processing with global process control and nanoscale deposit surface and materials specifications needs to be bridged. A breakthrough can only be realized if on each scale the occurring phenomena

  12. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  13. Indirect ultraviolet detection of alkaline earth metal ions using an imidazolium ionic liquid as an ultraviolet absorption reagent in ion chromatography.

    Science.gov (United States)

    Liu, Yong-Qiang; Yu, Hong

    2017-04-01

    A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Sound absorption of low-temperature reusable surface insulation candidate materials

    Science.gov (United States)

    Johnston, J. D.

    1974-01-01

    Sound absorption data from tests of four candidate low-temperature reusable surface insulation materials are presented. Limitations on the use of the data are discussed, conclusions concerning the effective absorption of the materials are drawn, and the relative significance to Vibration and Acoustic Test Facility test planning of the absorption of each material is assessed.

  15. Localized modes in optics of photonic liquid crystals with local anisotropy of absorption

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, V. A., E-mail: bel1937@mail.ru, E-mail: bel@landau.ac.ru [Russian Academy of Science, Landau Institute for Theoretical Physics (Russian Federation); Semenov, S. V. [National Research Center “Kurchatov Institute,” (Russian Federation)

    2016-05-15

    The localized optical modes in spiral photonic liquid crystals are theoretically studied for the certainty at the example of chiral liquid crystals (CLCs) for the case of CLC with an anisotropic local absorption. The model adopted here (absence of dielectric interfaces in the structures under investigation) makes it possible to get rid of mixing of polarizations on the surfaces of the CLC layer and of the defect structure and to reduce the corresponding equations to only the equations for light with polarization diffracting in the CLC. The dispersion equations determining connection of the edge mode (EM) and defect mode (DM) frequencies with the CLC layer parameters (anisotropy of local absorption, CLC order parameter) and other parameters of the DMS are obtained. Analytic expressions for the transmission and reflection coefficients of CLC layer and DMS for the case of CLC with an anisotropic local absorption are presented and analyzed. It is shown that the CLC layers with locally anisotropic absorption reduce the EM and DM lifetimes (and increase the lasing threshold) in the way different from the case of CLC with an isotropic local absorption. Due to the Borrmann effect revealing of which is different at the opposite stop-band edges in the case of CLC layers with an anisotropic local absorption the EM life-times for the EM frequencies at the opposite stop-bands edges may be significantly different. The options of experimental observations of the theoretically revealed phenomena are briefly discussed.

  16. Atmospheric pressure and temperature profiling using near IR differential absorption lidar

    Science.gov (United States)

    Korb, C. L.; Schwemmer, G. K.; Dombrowski, M.; Weng, C. Y.

    1983-01-01

    The present investigation is concerned with differential absorption lidar techniques for remotely measuring the atmospheric temperature and pressure profile, surface pressure, and cloud top pressure-height. The procedure used in determining the pressure is based on the conduction of high-resolution measurements of absorption in the wings of lines in the oxygen A band. Absorption with respect to these areas is highly pressure sensitive in connection with the mechanism of collisional line broadening. The method of temperature measurement utilizes a determination of the absorption at the center of a selected line in the oxygen A band which originates from a quantum state with high ground state energy.

  17. A universal reduced glass transition temperature for liquids

    Science.gov (United States)

    Fedors, R. F.

    1979-01-01

    Data on the dependence of the glass transition temperature on the molecular structure for low-molecular-weight liquids are analyzed in order to determine whether Boyer's reduced glass transition temperature (1952) is a universal constant as proposed. It is shown that the Boyer ratio varies widely depending on the chemical nature of the molecule. It is pointed out that a characteristic temperature ratio, defined by the ratio of the sum of the melting temperature and the boiling temperature to the sum of the glass transition temperature and the boiling temperature, is a universal constant independent of the molecular structure of the liquid. The average value of the ratio obtained from data for 65 liquids is 1.15.

  18. Distributed temperature sensor testing in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig; Bremer, Nathan; Lisowski, Darius; Lomperski, Stephen

    2017-02-01

    Rayleigh-backscatter-based distributed fiber optic sensors were immersed in sodium to obtain high-resolution liquid-sodium temperature measurements. Distributed temperature sensors (DTSs) functioned well up to 400°C in a liquid sodium environment. The DTSs measured sodium column temperature and the temperature of a complex geometrical pattern that leveraged the flexibility of fiber optics. A single Ø 360 lm OD sensor registered dozens of temperatures along a length of over one meter at 100 Hz. We also demonstrated the capability to use a single DTS to simultaneously detect thermal interfaces (e.g. sodium level) and measure temperature.

  19. Temperature-dependent liquid metal flowrate control device

    International Nuclear Information System (INIS)

    Carlson, R.D.

    1978-01-01

    A temperature-dependent liquid metal flowrate control device includes a magnet and a ferromagnetic member defining therebetween a flow path for liquid metal, the ferromagnetic member being formed of a material having a curie temperature at which a change in the flow rate of the liquid metal is desired. According to the preferred embodiment the magnet is a cylindrical rod magnet axially disposed within a cylindrical member formed of a curie material and having iron pole pieces at the ends. A cylindrical iron shunt and a thin wall stainless steel barrier are disposed in the annulus between magnet and curie material. Below the curie temperature flow between steel barrier and curie material is impeded and above the curie temperature flow impedance is reduced

  20. Universality of the high-temperature viscosity limit of silicate liquids

    DEFF Research Database (Denmark)

    Zheng, Qiuju; Mauro, John C.; Ellison, Adam J.

    2011-01-01

    We investigate the high-temperature limit of liquid viscosity by analyzing measured viscosity curves for 946 silicate liquids and 31 other liquids including metallic, molecular, and ionic systems. Our results show no systematic dependence of the high-temperature viscosity limit on chemical...... composition for the studied liquids. Based on theMauro-Yue-Ellison-Gupta-Allan (MYEGA) model of liquid viscosity, the high-temperature viscosity limit of silicate liquids is 10−2.93 Pa·s. Having established this value, there are only two independent parameters governing the viscosity-temperature relation...

  1. Solvated electron: criticism of a suggested correlation of chemical potential with optical absorption energy

    International Nuclear Information System (INIS)

    Farhataziz, M.

    1984-01-01

    A recent theoretical treatment of the absorption spectrum of the solvated electron, e - sub(s), maintains that rigorously μ 0 >= -0.75 Esub(av), which gives empirical relationship, μ 0 >= -(0.93 +- 0.02)Esub(max). For e - sub(s) in a particular solvent at a temperature and pressure, μ 0 , Esub(av) and Esub(max) are standard chemical potential, average energy of the absorption spectrum and the energy at the absorption maximum respectively. The temperature and pressure effects on the absorption spectrum of e - sub(s) in water and liquid ammonia do not support the equality sign in the above cited relationships. The implications of inequality expressed above are discussed for e - sub(s) in water and liquid ammonia. (author)

  2. Measurement of the Spectral Absorption of Liquid Water in Melting Snow With an Imaging Spectrometer

    Science.gov (United States)

    Green, Robert O.; Dozier, Jeff

    1995-01-01

    Melting of the snowpack is a critical parameter that drives aspects of the hydrology in regions of the Earth where snow accumulates seasonally. New techniques for measurement of snow melt over regional scales offer the potential to improve monitoring and modeling of snow-driven hydrological processes. In this paper we present the results of measuring the spectral absorption of liquid water in a melting snowpack with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS data were acquired over Mammoth Mountain, in east central California on 21 May 1994 at 18:35 UTC. The air temperature at 2926 m on Mammoth Mountain at site A was measured at 15-minute intervals during the day preceding the AVIRIS data acquisition. At this elevation. the air temperature did not drop below freezing the night of the May 20 and had risen to 6 degrees Celsius by the time of the overflight on May 21. These temperature conditions support the presence of melting snow at the surface as the AVIRIS data were acquired.

  3. Effect of adrenaline and alpha-agonists on net rate of liquid absorption from the pleural space of rabbits.

    Science.gov (United States)

    Zocchi, L; Raffaini, A; Agostoni, E

    1997-05-01

    Indirect evidence supporting a solute-coupled liquid absorption from the pleural space of rabbits has recently been provided; moreover, the beta 2-adrenoceptor agonist terbutaline has been found to increase this absorption. In this study the effect of adrenaline and alpha-adrenoceptor agonists on net rate of liquid absorption (Jnet) from albumin Ringer hydrothoraces of various sizes has been determined in anaesthetized rabbits. In hydrothoraces with adrenaline (5 x 10(-6) M) the relationship between Jnet and volume of liquid injected was displaced upwards by 0.09 ml h-1 relative to that in control hydrothoraces (P liquid absorption, since beta-agonists inhibit lymphatic activity while, at relatively high concentrations, they may increase active transport. Conversely, the strong stimulation of lymphatic alpha-receptors that should occur with adrenaline after beta-blockade may fail to increase lymphatic drainage, because it has been shown that the increase in contraction frequency of lymphatics may be balanced by the decrease in their stroke volume. Arterial blood pressure during the hydrothoraces with adrenaline was unchanged. In hydrothoraces with the alpha 2-agonist clonidine (5 x 10(-6) M; a less potent agent than adrenaline) the slope of the relationship between Jnet and volume injected increased by 26% (P liquid load. In hydrothoraces with the alpha 1-agonist phenylephrine (5 x 10(-6) or 10(-7) M) Jnet was simlar to control values.

  4. (Alpha-) quenching temperature dependence in liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Arnd; Lozza, Valentina; Krosigk, Belina von; Zuber, Kai [Institut fuer Kern- und Teilchenphysik, TU Dresden (Germany)

    2015-07-01

    Liquid scintillator (LS) is an effective and promising detector material, which is and will be used by many small and large scale experiments. In order to perform correct signal identification and background suppression, a very good knowledge of LS properties is crucial. One of those is the light yield from alpha particles in liquid scintillator. This light output strongly quenched, approx. 10 times compared to that of electrons, and has been precisely studied at room temperature for various LS. Big scintillator experiments, such as SNO+ and maybe future large scale detectors, will operate at different temperatures. While a strong temperature dependence is well known for solid state scintillators, due to the different scintillation process, a quenching temperature dependence in LS is usually assumed negligible. On the other hand, inconsistencies in between measurements are often explained by potential temperature effects. This study investigates LAB based liquid scintillator with an intrinsic, dissolved alpha emitter and its behaviour with temperature change. In a small, cooled and heated setup, a stabilized read-out with two PMTs is realised. First results are presented.

  5. Liquid-liquid structure transition and nucleation in undercooled Co-B eutectic alloys

    Energy Technology Data Exchange (ETDEWEB)

    He, Yixuan [Northwestern Polytechnical University, State Key Laboratory of Solidification Processing, Xi' an, Shanxi (China); Universite Grenoble Alpes, LNCMI, Grenoble (France); CNRS, LNCMI, Grenoble (France); Li, Jinshan; Wang, Jun; Kou, Hongchao [Northwestern Polytechnical University, State Key Laboratory of Solidification Processing, Xi' an, Shanxi (China); Beagunon, Eric [Universite Grenoble Alpes, LNCMI, Grenoble (France); CNRS, LNCMI, Grenoble (France)

    2017-06-15

    Cyclic superheating and cooling were carried out for the undercooled hypereutectic Co{sub 80}B{sub 20}, eutectic Co{sub 81.5}B{sub 18.5,} and hypoeutectic Co{sub 83}B{sub 17} alloys. For each alloy, there is a critical overheating temperature T{sub c}° at which there is a sharp increase of the mean undercooling, i.e., below (above) T{sub c}°, and the mean undercooling is about 80 °C (200 °C). DSC measurements show that there is a thermal absorption peak in the heating process, the peak temperature of which is nearly equal to the critical overheating temperature, indicating that the temperature-induced liquid-liquid structure transition does occur and should relate highly to nucleation in the undercooled Co-B eutectic melts. The effect of the liquid-liquid structure transition on nucleation was interpreted by the recent nucleation theory that considers the structures of overheated melts, and the composition-dependent overheating temperature was ascribed to the change of local favored structures. The present work provides further evidences for the liquid-liquid structure transition and is helpful for understanding solidification in undercooled melts. (orig.)

  6. Electronic absorption spectrum of copper-doped magnesium potassium phosphate hexahydrate

    Science.gov (United States)

    Rao, S. N.; Sivaprasad, P.; Reddy, Y. P.; Rao, P. S.

    1992-04-01

    The optical absorption and EPR spectra of magnesium potassium phosphate hexahydrate (MPPH) doped with copper ions are recorded both at room and liquid nitrogen temperatures. The spectrum is characteristic of Cu2+ in tetragonal symmetry. The spin-Hamiltonian parameters and molecular orbital coefficients are evaluated. A correlation between EPR and optical absorption studies is drawn.

  7. Effect on phloridzin on net rate of liquid absorption from the pleural space of rabbits.

    Science.gov (United States)

    Zocchi, L; Agostoni, E; Raffaini, A

    1996-11-01

    Previous indirect findings have suggested the occurrence of solute-coupled liquid absorption from the pleural space, consistent with Na(+)-K(+)-ATPase on the interstitial side plus a Na(+)-H+ and CI(-)-HCO3- double exchange on the luminal side of the pleural mesothelium. To assess whether Na(+)-glucose cotransport also operates on the luminal side, the relationship between net rate of liquid absorption from the right pleural space (Jnet) and volume of liquid injected into this space (0.5, 1 or 2 ml) was determined in anaesthetized rabbits during hydrothoraces with phloridzin (10(-3)M) or with phloridzin plus 4-acetamido-4'-isothiocyanatostilbene-2, 2'-disulphonic acid (SITS; 1.5 x 10(-4)M). The relationship obtained during hydrothoraces with phloridzin was displaced downwards by 0.09 ml h-1 relative to that in control hydrothoraces (P pleural mesothelium, operating simultaneously with the double exchange also under physiological conditions.

  8. Frequency up-shift in the stimulated thermal scattering under two-photon absorption in liquids and colloids of metal nanoparticles

    Science.gov (United States)

    Smetanin, I. V.; Erokhin, A. I.; Baranov, A. N.

    2018-07-01

    We report the results of the experimental and theoretical study of stimulated temperature scattering in toluene and hexane solutions of Ag-nanoparticles, as well as in pure toluene in the two-photon absorption regime. A four-wave mixing scheme with two counter-propagating pump waves of the same frequency is utilised to demonstrate the lasing effect and the amplification of the backscattered anti-Stokes signal. For the first time, we have measured anti-Stokes spectral shifts which turn out to appreciably exceed the Rayleigh line widths in those liquids. It is shown that the amplification effect is provided predominantly by thermally induced coherent polarisation oscillations, while the dynamic interference temperature grating causes the formation of a self-induced optical cavity inside the interaction region.

  9. Temperature quenching in LAB based liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, A.; Zuber, K. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); Hans, S.; Yeh, M. [Brookhaven National Laboratory, Chemistry Devision, Upton, NY (United States); Junghans, A.R.; Koegler, T.; Wagner, A. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Krosigk, B. v. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); University of British Columbia, Department of Physics and Astronomy, Vancouver, BC (Canada); Lozza, V. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); Laboratorio de Instrumentacao e Fisica Experimental de Particulas, Lisboa (Portugal)

    2018-01-15

    The effect of temperature changes on the light output of LAB based liquid scintillator is investigated in a range from -5 to 30 C with α-particles and electrons in a small scale setup. Two PMTs observe the scintillator liquid inside a cylindrically shaped aluminum cuvette that is heated or cooled and the temperature dependent PMT sensitivity is monitored and corrected. The α-emitting isotopes in dissolved radon gas and in natural Samarium (bound to a LAB solution) excite the liquid scintillator mixtures and changes in light output with temperature variation are observed by fitting light output spectra. Furthermore, also changes in light output by compton electrons, which are generated from external calibration γ-ray sources, is analysed with varying temperature. Assuming a linear behaviour, a combined negative temperature coefficient of (-0.29 ± 0.01)%/ C is found. Considering hints for a particle type dependency, electrons show (-0.17 ± 0.02)%/ C, whereas the temperature dependency seems stronger for α-particles, with (-0.35 ± 0.03)%/ C. Due to a high sampling rate, a pulse shape analysis can be performed and shows an enhanced slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations. (orig.)

  10. (Liquid + liquid) equilibria for (water + 1-propanol or acetone + β-citronellol) at different temperatures

    International Nuclear Information System (INIS)

    Li, Hengde; Han, Yongtao; Huang, Cheng; Yang, Chufen

    2015-01-01

    Graphical abstract: (Liquid + liquid) equilibrium data for systems composed of β-citronellol and aqueous 1-propanol or acetone are presented. Distribution ratios of 1-propanol and acetone in the mixtures are examined. The effect of the temperature on the ternary (liquid + liquid) equilibria is evaluated and discussed. - Highlights: • Ternary (liquid + liquid) equilibria containing β-citronellol are presented. • Distribution ratios of 1-propanol and acetone in the mixtures are examined. • The effect on the temperature of the systems is evaluated and discussed. - Abstract: On this paper, experimental (liquid + liquid) equilibrium (LLE) results are presented for systems composed of β-citronellol and aqueous 1-propanol or acetone. To evaluate the phase separation properties of β-citronellol in aqueous mixtures, LLE values for the ternary systems (water + 1-propanol + β-citronellol) and (water + acetone + β-citronellol) were determined with a tie-line method at T = (283.15, 298.15, and 313.15 ± 0.02) K and atmospheric pressure. The reliability of the experimental tie-lines was verified by the Hand and Bachman equations. Ternary phase diagrams, distribution ratios of 1-propanol and acetone in the mixtures are shown. The effect of the temperature on the ternary (liquid + liquid) equilibria was examined and discussed. The experimental LLE values were satisfactorily correlated by extended UNIQUAC and modified UNIQUAC models

  11. Selective Reversible Absorption of the Industrial Off-Gas Components CO2 and NOx by Ionic Liquids

    DEFF Research Database (Denmark)

    Kaas-Larsen, Peter Kjartan; Thomassen, Peter; Schill, Leonard

    2016-01-01

    Ionic liquids are promising new materials for climate and pollution control by selective absorption of CO2 and NOx in industrial off-gases. In addition pratical cleaning of industrial off gases seems to be attractive by use of ionic liquids distributed on the surface of porous, high surface area...

  12. VOC and HAP recovery using ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Michael R. Milota : Kaichang Li

    2007-05-29

    During the manufacture of wood composites, paper, and to a lesser extent, lumber, large amounts of volatile organic compounds (VOCs) such as terpenes, formaldehyde, and methanol are emitted to air. Some of these compounds are hazardous air pollutants (HAPs). The air pollutants produced in the forest products industry are difficult to manage because the concentrations are very low. Presently, regenerative thermal oxidizers (RTOs and RCOs) are commonly used for the destruction of VOCs and HAPs. RTOs consume large amounts of natural gas to heat air and moisture. The combustion of natural gas generates increased CO2 and NOx, which have negative implications for global warming and air quality. The aforementioned problems are addressed by an absorption system containing a room-temperature ionic liquid (RTIL) as an absorbent. RTILs are salts, but are in liquid states at room temperature. RTILs, an emerging technology, are receiving much attention as replacements for organic solvents in industrial processes with significant cost and environmental benefits. Some of these processes include organic synthesis, extraction, and metal deposition. RTILs would be excellent absorbents for exhausts from wood products facilities because of their unique properties: no measurable vapor pressure, high solubility of wide range of organic compounds, thermal stability to 200°C (almost 400°F), and immisciblity with water. Room temperature ionic liquids were tested as possible absorbents. Four were imidizolium-based and were eight phosphonium-based. The imidizolium-based ionic liquids proved to be unstable at the conditions tested and in the presence of water. The phosphonium-based ionic liquids were stable. Most were good absorbents; however, cleaning the contaminates from the ionic liquids was problematic. This was overcome with a higher temperature (120°C) than originally proposed and a very low pressure (1 kPa. Absorption trials were conducted with tetradecy

  13. Temperature dependence of the absorption coefficient of water for midinfrared laser radiation

    NARCIS (Netherlands)

    Jansen, E. D.; van Leeuwen, T. G.; Motamedi, M.; Borst, C.; Welch, A. J.

    1994-01-01

    The dynamics of the water absorption peak around 1.94 microns was examined. This peak is important for the absorption of holmium and thulium laser radiation. To examine the effect of temperature on the absorption coefficient, the transmission of pulsed Ho:YAG, Ho:YAG, Ho:YSGG, and Tm:YAG laser

  14. Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Zeini Jahromi, Elham; Bidari, Araz; Assadi, Yaghoub; Milani Hosseini, Mohammad Reza; Jamali, Mohammad Reza

    2007-01-01

    Dispersive liquid-liquid microextraction (DLLME) technique was successfully used as a sample preparation method for graphite furnace atomic absorption spectrometry (GF AAS). In this extraction method, 500 μL methanol (disperser solvent) containing 34 μL carbon tetrachloride (extraction solvent) and 0.00010 g ammonium pyrrolidine dithiocarbamate (chelating agent) was rapidly injected by syringe into the water sample containing cadmium ions (interest analyte). Thereby, a cloudy solution formed. The cloudy state resulted from the formation of fine droplets of carbon tetrachloride, which have been dispersed, in bulk aqueous sample. At this stage, cadmium reacts with ammonium pyrrolidine dithiocarbamate, and therefore, hydrophobic complex forms which is extracted into the fine droplets of carbon tetrachloride. After centrifugation (2 min at 5000 rpm), these droplets were sedimented at the bottom of the conical test tube (25 ± 1 μL). Then a 20 μL of sedimented phase containing enriched analyte was determined by GF AAS. Some effective parameters on extraction and complex formation, such as extraction and disperser solvent type and their volume, extraction time, salt effect, pH and concentration of the chelating agent have been optimized. Under the optimum conditions, the enrichment factor 125 was obtained from only 5.00 mL of water sample. The calibration graph was linear in the rage of 2-20 ng L -1 with detection limit of 0.6 ng L -1 . The relative standard deviation (R.S.D.s) for ten replicate measurements of 20 ng L -1 of cadmium was 3.5%. The relative recoveries of cadmium in tap, sea and rivers water samples at spiking level of 5 and 10 ng L -1 are 108, 95, 87 and 98%, respectively. The characteristics of the proposed method have been compared with cloud point extraction (CPE), on-line liquid-liquid extraction, single drop microextraction (SDME), on-line solid phase extraction (SPE) and co-precipitation based on bibliographic data. Therefore, DLLME combined with

  15. Temperature dependence of absorption spectra of P-type GaP

    International Nuclear Information System (INIS)

    Mounir, M.; Balloomal, L.S.

    1985-10-01

    The theoretical analysis of the optical absorption due to band-impurity (impurity-band) electron transitions involving deep impurity levels in semi-conductors is considered. Also the data of the experimental absorption spectra of GaP were performed at room temperature and the results were found to be in agreement with the theoretical results if the electron-phonon interaction is taken into consideration. (author)

  16. Absorption cross-section measurements of methane, ethane, ethylene and methanol at high temperatures

    KAUST Repository

    Alrefae, Majed

    2014-09-01

    Mid-IR absorption cross-sections are measured for methane, ethane, ethylene and methanol over 2800-3400 cm-1 (2.9-3.6 μm) spectral region. Measurements are carried out using a Fourier-Transform-Infrared (FTIR) spectrometer with temperatures ranging 296-1100 K and pressures near atmospheric. As temperature increases, the peak cross-sections decrease but the wings of the bands increase as higher rotational lines appear. Integrated band intensity is also calculated over the measured spectral region and is found to be a very weak function of temperature. The absorption cross-sections of the relatively small fuels studied here show dependence on the bath gas. This effect is investigated by studying the variation of absorption cross-sections at 3.392 μm using a HeNe laser in mixtures of fuel and nitrogen, argon, or helium. Mixtures of fuel with He have the highest value of absorption cross-sections followed by Ar and N2. Molecules with narrow absorption lines, such as methane and methanol, show strong dependence on bath gas than molecules with relatively broader absorption features i.e. ethane and ethylene. © 2014 Elsevier Inc. All rights reserved.

  17. Structural studies on volatile, air and moisture sensitive liquids at ambient and elevated temperatures using liquid X-ray scattering. The structure of liquid gallium (III) chloride systems

    Science.gov (United States)

    Ulvenlund, Stefan; Bengtsson, Lars A.

    1994-09-01

    An X-ray scattering method is presented which provides accurate structural information on air and moisture sensitive liquids at ambient and elevated temperatures using a standard θ-θ X-ray diffractometer. The method utilizes capillary glass tubes as sample containers and requires no corrections for sample container absorption or scattering, as shown by structural studies of well-known systems such as benzene, carbon tetrachloride and antimony trichloride. Artefacts produced by the sample holder are insignificant and very easy to correct for. The major drawback of the method is the long time of experiment, due to the small (compared with the standard set-up) area/volume ratio of the liquid which contributes to the intensity of the scattered radiation. However, the time required is not unduly long except for liquids containing light elements only (very low scattering power) or very heavy ones (high liner absorptivity). Liquid GaCl 3 is shown to have a dimeric structure consisting of edge-sharing GaCl 4 tetrahedra. This structure is analogous to that previously found for GaCl 3 in the gaseous and solid state and for AlCl 3 in the gaseous and liquid state. Concentrated solutions of GaCl 3 in benzene have been shown to comprise monomeric GaCl 3 units with C3v symmetry. However, it is suggested that such units form as a result of a radiolytically induced cleavage of the Ga 2Cl 6 moieties. No GaC correlation is resolved, which is explained by assuming a σ-type complex GaCl 3 and benzene and/or an ill-defined interaction between the GaCl 3 unit and benzene. The former sitution would most probably produce too few GaC correlation to be observable by the present method, whereas the latter situation would produce a very broad GaC correlation difficult to separate from the background. However, the deviation from the D3h symmetry adopted by GaCl 3 in the gas phase indicates a specific interation between GaCl 3 and benzene.

  18. The approximate determination of the critical temperature of a liquid by measuring surface tension versus the temperature

    International Nuclear Information System (INIS)

    Maroto, J A; Nieves, F J de las; Quesada-Perez, M

    2004-01-01

    A classical experience in a physics student laboratory is to determine the surface tension of a liquid versus the temperature and to check the linear appearance of the obtained graph. In this work we show a simple method to estimate the critical temperature of three liquids by using experimental data of surface tension at different temperatures. By a logarithm fitting between surface tension and temperature, the critical temperature can be determined and compared with data from the literature. For two liquids (butanol and nitrobenzene) the comparison is acceptable but the differences are too high for the third liquid (water). By discussing the results it seems to be clear that the difference between the critical temperature of the liquid and the maximum temperature of the surface tension measurements is the determining factor in obtaining acceptable results. From this study it is possible to obtain more information on the liquid characteristics from surface tension measurements that are currently carried out in a student laboratory. Besides, in this paper it is shown how to select the most suitable liquids which provide both acceptable values for the critical temperature and measurements of the surface tension at moderate temperatures. The complementary use of numerical methods permits us to offer a complete experience for the students with a simple laboratory experiment which we recommend for physics students in advanced university courses

  19. Laboratory studies of H retention and LiH formation in liquid lithium

    Energy Technology Data Exchange (ETDEWEB)

    Martín-Rojo, A.B. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); UC3M Madrid, 126, 28903 Getafe (Spain); Oyarzabal, E. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); U.N.E.D. Ciudad Universitaria, S/N, 28040, Madrid Spain (Spain); Tabarés, F.L., E-mail: tabares@ciemat.es [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain)

    2014-12-15

    Highlights: • Absorption and thermal desorption experiments of hydrogen isotopes in liquid lithium have been performed at exposure temperatures up to 400 °C. • The kinetics of the involved processes indicate a two-stage mechanism for hydride production. • TDS peaks at temperatures well below the expected one for thermal decomposition of the hydride were systematically recorded, although only a small fraction of the absorbed gas was released during the TDS cycle. • The absorption of H{sub 2} in a D{sub 2}-loaded sample was investigated at two temperatures, and no obvious influence of the preexisting species in the rate of absorption of H{sub 2} was seen. • Deuterium absorption takes place at a higher rate than that of hydrogen. - Abstract: Laboratory experiments on H/D retention on liquid lithium followed by thermal desorption spectrometry (TDS) have been performed at Ciemat. Two different experimental set ups were used in order to expose liquid Li to hydrogen gas or to hydrogen glow discharge plasmas at temperatures up to 673 K. In the present work the results concerning the gas phase absorption are addressed. Two different kinetics of absorption were identified from the time evolution of the uptake. Alternate exposures to H{sub 2} and D{sub 2} were carried out in order to study the isotope exchange and its possible use for tritium retention control in Fusion Reactor. Although important differences were found in the absorption kinetics of both species, the total retention seems to be governed by the total sum of hydrogenic isotopes, and only small differences were found in the corresponding TDS spectra, on which evidence of some isotope exchange is observed. The results are discussed in relation to the potential use of liquid lithium walls in a Fusion Reactor.

  20. Laboratory studies of H retention and LiH formation in liquid lithium

    International Nuclear Information System (INIS)

    Martín-Rojo, A.B.; Oyarzabal, E.; Tabarés, F.L.

    2014-01-01

    Highlights: • Absorption and thermal desorption experiments of hydrogen isotopes in liquid lithium have been performed at exposure temperatures up to 400 °C. • The kinetics of the involved processes indicate a two-stage mechanism for hydride production. • TDS peaks at temperatures well below the expected one for thermal decomposition of the hydride were systematically recorded, although only a small fraction of the absorbed gas was released during the TDS cycle. • The absorption of H 2 in a D 2 -loaded sample was investigated at two temperatures, and no obvious influence of the preexisting species in the rate of absorption of H 2 was seen. • Deuterium absorption takes place at a higher rate than that of hydrogen. - Abstract: Laboratory experiments on H/D retention on liquid lithium followed by thermal desorption spectrometry (TDS) have been performed at Ciemat. Two different experimental set ups were used in order to expose liquid Li to hydrogen gas or to hydrogen glow discharge plasmas at temperatures up to 673 K. In the present work the results concerning the gas phase absorption are addressed. Two different kinetics of absorption were identified from the time evolution of the uptake. Alternate exposures to H 2 and D 2 were carried out in order to study the isotope exchange and its possible use for tritium retention control in Fusion Reactor. Although important differences were found in the absorption kinetics of both species, the total retention seems to be governed by the total sum of hydrogenic isotopes, and only small differences were found in the corresponding TDS spectra, on which evidence of some isotope exchange is observed. The results are discussed in relation to the potential use of liquid lithium walls in a Fusion Reactor

  1. Determination of Scattering and Absorption Coefficients for Plasma-Sprayed Yttria-Stabilized Zirconia Thermal Barrier Coatings at Elevated Temperatures

    Science.gov (United States)

    Eldridge, Jeffrey I.; Spuckler, Charles M.; Markham, James R.

    2009-01-01

    The temperature dependence of the scattering and absorption coefficients for a set of freestanding plasma-sprayed 8 wt% yttria-stabilized zirconia (8YSZ) thermal barrier coatings (TBCs) was determined at temperatures up to 1360 C in a wavelength range from 1.2 micrometers up to the 8YSZ absorption edge. The scattering and absorption coefficients were determined by fitting the directional-hemispherical reflectance and transmittance values calculated by a four-flux Kubelka Munk method to the experimentally measured hemispherical-directional reflectance and transmittance values obtained for five 8YSZ thicknesses. The scattering coefficient exhibited a continuous decrease with increasing wavelength and showed no significant temperature dependence. The scattering is primarily attributed to the relatively temperature-insensitive refractive index mismatch between the 8YSZ and its internal voids. The absorption coefficient was very low (less than 1 per centimeter) at wavelengths between 2 micrometers and the absorption edge and showed a definite temperature dependence that consisted of a shift of the absorption edge to shorter wavelengths and an increase in the weak absorption below the absorption edge with increasing temperature. The shift in the absorption edge with temperature is attributed to strongly temperature-dependent multiphonon absorption. While TBC hemispherical transmittance beyond the absorption edge can be predicted by a simple exponential decrease with thickness, below the absorption edge, typical TBC thicknesses are well below the thickness range where a simple exponential decrease in hemispherical transmittance with TBC thickness is expected. [Correction added after online publication August 11, 2009: "edge to a shorter wavelengths" has been updated as edge to shorter wavelengths."

  2. Ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometric for selenium speciation in foods and beverages.

    Science.gov (United States)

    Tuzen, Mustafa; Pekiner, Ozlem Zeynep

    2015-12-01

    A rapid and environmentally friendly ultrasound assisted ionic liquid dispersive liquid liquid microextraction (USA-IL-DLLME) was developed for the speciation of inorganic selenium in beverages and total selenium in food samples by using graphite furnace atomic absorption spectrometry. Some analytical parameters including pH, amount of complexing agent, extraction time, volume of ionic liquid, sample volume, etc. were optimized. Matrix effects were also investigated. Enhancement factor (EF) and limit of detection (LOD) for Se(IV) were found to be 150 and 12 ng L(-1), respectively. The relative standard deviation (RSD) was found 4.2%. The accuracy of the method was confirmed with analysis of LGC 6010 Hard drinking water and NIST SRM 1573a Tomato leaves standard reference materials. Optimized method was applied to ice tea, soda and mineral water for the speciation of Se(IV) and Se(VI) and some food samples including beer, cow's milk, red wine, mixed fruit juice, date, apple, orange, grapefruit, egg and honey for the determination of total selenium. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Optimum hot water temperature for absorption solar cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lecuona, A.; Ventas, R.; Venegas, M.; Salgado, R. [Dpto. Ingenieria Termica y de Fluidos, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganes, Madrid (Spain); Zacarias, A. [ESIME UPA, IPN, Av. de las Granjas 682, Col. Santa Catarina, 02550, D.F. Mexico (Mexico)

    2009-10-15

    The hot water temperature that maximizes the overall instantaneous efficiency of a solar cooling facility is determined. A modified characteristic equation model is used and applied to single-effect lithium bromide-water absorption chillers. This model is based on the characteristic temperature difference and serves to empirically calculate the performance of real chillers. This paper provides an explicit equation for the optimum temperature of vapor generation, in terms of only the external temperatures of the chiller. The additional data required are the four performance parameters of the chiller and essentially a modified stagnation temperature from the detailed model of the thermal collector operation. This paper presents and discusses the results for small capacity machines for air conditioning of homes and small buildings. The discussion highlights the influence of the relevant parameters. (author)

  4. Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption

    Science.gov (United States)

    Ma, Qiancheng

    2014-01-01

    The water-vapor continuum absorption plays an important role in the radiative balance in the Earth's atmosphere. It has been experimentally shown that for ambient atmospheric conditions, the continuum absorption scales quadratically with the H2O number density and has a strong, negative temperature dependence (T dependence). Over the years, there have been three different theoretical mechanisms postulated: far-wings of allowed transition lines, water dimers, and collision-induced absorption. The first mechanism proposed was the accumulation of absorptions from the far-wings of the strong allowed transition lines. Later, absorption by water dimers was proposed, and this mechanism provides a qualitative explanation for the continuum characters mentioned above. Despite the improvements in experimental data, at present there is no consensus on which mechanism is primarily responsible for the continuum absorption.

  5. Glass Transitions and Low-Frequency Dynamics of Room-Temperature Ionic Liquids

    International Nuclear Information System (INIS)

    Yamamuro, O.; Inamura, Y.; Hayashi, S.; Hamaguchi, H.

    2006-01-01

    We have measured the heat capacity and neutrion quasi- and inelastic scattering spectra of some salts of 1-butyl-3-methylimidazolium ion bmim+, which is a typical cation of room-temperature ionic liquids, and its derivatives. The heat capacity measurements revealed that the room-temperature ionic liquids have glass transitions as molecular liquids. The temperature dependence of configurational entropy demonstrated that the room-temperature ionic liquids are 'fragile liquids'. Both heat capacity and inelastic neutron scattering data revealed that the glassy phases exhibit large low-energy excitations usually called 'boson peak'. The quasielastic neutron scattering data showed that so-called 'fast process' appears around Tg as in molecular and polymer glasses. The temperature dependence of the self-diffusion coefficient derived from the neutron scattering data indicated that the orientation of bmim+ ions and/or butyl-groups of bmim+ ions is highly disordered and very flexible in an ionic liquid phase

  6. The effect of self-absorption in hollow cathode lamp on its temperature

    International Nuclear Information System (INIS)

    Sobhanian, S.; Naghshara, H.

    2014-01-01

    It has been shown experimentally that even a small error in the calculation of the temperature inside the hollow-cathode lamp (HCL) and the current applied to the lamp, may cause a tremendous error in determination of the absorption ratio in optical resonance absorption (ORA) method. This effect is intensified nonlinearity for large absorption ratios. If a higher current is applied to a copper hollow cathode lamp, the copper density inside the lamp is increasing rapidly. Due to the cylindrical (axisymmetric) form of the lamp, the density of atoms around the main axis of the lamp becomes greater than that near the internal wall. In this case the auto-absorption (or self-absorption) is occurred and as its result, the emission spectrum produced by copper atoms is locally absorbed before going out from the lamp. This absorption is stronger near the main axis compared with the areas near the wall because of the Gaussian profile of the spectral line. Two different Cu atoms ground state lines with the similar lower state (327.4 nm and 324.7 nm) are used in this work as optical resonance absorption and the absorption coefficient is obtained for three different pressures (0.6, 4.5 and 14 µbar). The best values for copper HCL temperature and for maximum HCL current were found respectively 450 K, and 5mA. (author)

  7. Revisiting the total ion yield x-ray absorption spectra of liquid water microjets

    International Nuclear Information System (INIS)

    Saykally, Richard J; Cappa, Chris D.; Smith, Jared D.; Wilson, Kevin R.; Saykally, Richard J.

    2008-01-01

    Measurements of the total ion yield (TIY) x-ray absorption spectrum (XAS) of liquid water by Wilson et al. (2002 J. Phys.: Condens. Matter 14 L221 and 2001 J. Phys. Chem. B 105 3346) have been revisited in light of new experimental and theoretical efforts by our group. Previously, the TIY spectrum was interpreted as a distinct measure of the electronic structure of the liquid water surface. However, our new results indicate that the previously obtained spectrum may have suffered from as yet unidentified experimental artifacts. Although computational results indicate that the liquid water surface should exhibit a TIY-XAS that is fundamentally distinguishable from the bulk liquid XAS, the new experimental results suggest that the observable TIY-XAS is actually nearly identical in appearance to the total electron yield (TEY-)XAS, which is a bulk probe. This surprising similarity between the observed TIY-XAS and TEY-XAS likely results from large contributions from x-ray induced electron stimulated desorption of ions, and does not necessarily indicate that the electronic structure of the bulk liquid and liquid surface are identical

  8. Liquid oxygen liquid acquisition device bubble point tests with high pressure lox at elevated temperatures

    Science.gov (United States)

    Jurns, J. M.; Hartwig, J. W.

    2012-04-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth's gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMDs) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122 K) as part of NASA's continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

  9. Determination of Zinc Ions in Environmental Samples by Dispersive Liquid- Liquid Micro Extraction and Atomic Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Arabi

    2012-11-01

    Full Text Available In this work preconcentration of the Zn ions was investigated in water sample by Dispersive liquid- liquid micro extraction (DLLME using chloroform as an extraction solvent, methanol as a disperser solvent and 8-Hydroxyquinoline as a chelating agent. The determination of extracted ions was done by graphite furnace atomic absorption spectrometry. The influence of various analytical parameters including pH, extraction and disperser solvent type and volume and concentration of the chelating agent on the extraction efficiency of analyses was investigated. After extraction, the enrichment factor was 26 and the detection limit of the method was 0.0033 µg l-1 and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Zn were 7.41%. 

  10. Electrochemical applications of room temperature ionic liquids in nuclear fuel cycle

    International Nuclear Information System (INIS)

    Venkatesan, K.A.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2008-01-01

    Applications of room temperature ionic liquids (RTILs) have invaded all branches of science. They are also receiving an upsurge, in recent years, for possible applications in various stages of nuclear fuel cycle. Ionic liquids are compounds composed entirely of ions existing in liquid state and RTILs are ionic liquids molten at temperatures lower than 373 K. RTILs are generally made up of an organic cation and an inorganic or an organic anion. Room temperature ionic liquids have several fascinating properties, which are unique to a particular combination of cation and anion. The properties such as insignificant vapor pressure, amazing ability to dissolve organic and inorganic compounds, wide electrochemical window are the specific advantages when dealing with application of RTILs for reprocessing of spent nuclear fuel. The ionic liquids are regarded as designer or tailor-made solvents as their properties can be tuned for desired application by appropriate cation-anion combinations. An excellent review by Wilkes describes about the historical perspectives of room temperature ionic liquids, pioneers in that area, events and the products delivered till 2001. Furthermore, several comprehensive reviews have been made on room temperature ionic liquids by various authors

  11. Studies of Water Absorption Behavior of Plant Fibers at Different Temperatures

    Science.gov (United States)

    Saikia, Dip

    2010-05-01

    Moisture absorption of natural fiber plastic composites is one major concern in their outdoor applications. The absorbed moisture has many detrimental effects on the mechanical performance of these composites. A knowledge of the moisture diffusivity, permeability, and solubility is very much essential for the application of natural fibers as an excellent reinforcement in polymers. An effort has been made to study the water absorption behavior of some natural fibers such as bowstring hemp, okra, and betel nut at different temperatures to improve the long-term performance of composites reinforced with these fibers. The gain in moisture content in the fibers due to water absorption was measured as a function of exposure time at temperatures ranging from 300 K to 340 K. The thermodynamic parameters of the sorption process, such as diffusion coefficients and corresponding activation energies, were estimated.

  12. Uncertainty budgets for liquid waveguide CDOM absorption measurements.

    Science.gov (United States)

    Lefering, Ina; Röttgers, Rüdiger; Utschig, Christian; McKee, David

    2017-08-01

    Long path length liquid waveguide capillary cell (LWCC) systems using simple spectrometers to determine the spectral absorption by colored dissolved organic matter (CDOM) have previously been shown to have better measurement sensitivity compared to high-end spectrophotometers using 10 cm cuvettes. Information on the magnitude of measurement uncertainties for LWCC systems, however, has remained scarce. Cross-comparison of three different LWCC systems with three different path lengths (50, 100, and 250 cm) and two different cladding materials enabled quantification of measurement precision and accuracy, revealing strong wavelength dependency in both parameters. Stable pumping of the sample through the capillary cell was found to improve measurement precision over measurements made with the sample kept stationary. Results from the 50 and 100 cm LWCC systems, with higher refractive index cladding, showed systematic artifacts including small but unphysical negative offsets and high-frequency spectral perturbations due to limited performance of the salinity correction. In comparison, the newer 250 cm LWCC with lower refractive index cladding returned small positive offsets that may be physically correct. After null correction of measurements at 700 nm, overall agreement of CDOM absorption data at 440 nm was found to be within 5% root mean square percentage error.

  13. A measurement of the absorption of liquid argon scintillation light by dissolved nitrogen at the part-per-million level

    International Nuclear Information System (INIS)

    Jones, B J P; Chiu, C S; Conrad, J M; Ignarra, C M; Katori, T; Toups, M

    2013-01-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10 −4 cm −1 ppm −1 , corresponding to an absorption cross section of (4.99±0.51) × 10 −21 cm 2 molecule −1 . We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±3 meters

  14. Heat Capacity of Room-Temperature Ionic Liquids: A Critical Review

    Science.gov (United States)

    Paulechka, Yauheni U.

    2010-09-01

    Experimental data on heat capacity of room-temperature ionic liquids in the liquid state were compiled and critically evaluated. The compilation contains data for 102 aprotic ionic liquids from 63 literature references and covers the period of time from 1998 through the end of February 2010. Parameters of correlating equations for temperature dependence of the heat capacities were developed.

  15. Highly Sensitive Liquid Core Temperature Sensor Based on Multimode Interference Effects

    Directory of Open Access Journals (Sweden)

    Miguel A. Fuentes-Fuentes

    2015-10-01

    Full Text Available A novel fiber optic temperature sensor based on a liquid-core multimode interference device is demonstrated. The advantage of such structure is that the thermo-optic coefficient (TOC of the liquid is at least one order of magnitude larger than that of silica and this, combined with the fact that the TOC of silica and the liquid have opposite signs, provides a liquid-core multimode fiber (MMF highly sensitive to temperature. Since the refractive index of the liquid can be easily modified, this allows us to control the modal properties of the liquid-core MMF at will and the sensor sensitivity can be easily tuned by selecting the refractive index of the liquid in the core of the device. The maximum sensitivity measured in our experiments is 20 nm/°C in the low-temperature regime up to 60 °C. To the best of our knowledge, to date, this is the largest sensitivity reported for fiber-based MMI temperature sensors.

  16. Specific features of the temperature dependence of the exciton absorption integral in CdS crystals

    International Nuclear Information System (INIS)

    Novikov, A.B.; Solov'ev, L.E.; Talalaev, V.G.

    1986-01-01

    Cadmium sulfide crystals 0.4-2 μm thick in the 4.2-120 K temperature range are investigated experimentally. The shape of the first exciton absorption line in CdS and dependence of integral exciton absorption factor (IEAF) on the quenching constant j are calculated. Rapid growth of the absorption factor in the maximum of the absorption line and decrease of halfwidth of the factor are shown to take place with j increase. The calculation has disclosed that the Bouguer law is observed excluding negligible IEAF oscillations at variation of crystal thickness. Non-monotonous temperature dependence of IEAF is disclosed in some investigated samples; it, obviously, testifies to non-monotonous temperature dependence of j. Depolarization of the absorption line of high-energy exciton states with n=2 and n=3 is discovered in some samples for the first time

  17. Liquid-Liquid Extraction and Determination of Trace Elements in Iron Minerals by Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Taseska, Milena; Stafilov, Trajche; Makreski, Petre; Jacimovic, Radojko; Jovanovski, Gligor

    2006-01-01

    Various trace elements (cadmium, chromium, cobalt, nickel, manganese) in some iron minerals were determined by flame (FAAS) and electrothermal atomic absorption spectrometry (ETAAS). The studied minerals were chalcopyrite (CuFeS 2 ), hematite (Fe 2 O 3 ) and pyrite (FeS 2 ). To avoid the interference of iron, a method for liquid-liquid extraction of iron and determination of investigated elements in the inorganic phase was proposed. Iron was extracted by diisopropyl ether in hydrochloride acid solution and the extraction method was optimized. Some parameters were obtained to be significantly important: Fe mass in the sample should not exceed 0.3 g, the optimal concentration of HCI should be 7.8 mol 1 -1 and ratio of the inorganic and organic phase should be 1: 1. The procedure was verified by the method of standard additions and by its applications to reference standard samples. The investigated minerals originate from various mines in the Republic of Macedonia. (Author)

  18. Analysis of gas absorption to a thin liquid film in the presence of a zero-order chemical reaction

    Science.gov (United States)

    Rajagopalan, S.; Rahman, M. M.

    1995-01-01

    The paper presents a detailed theoretical analysis of the process of gas absorption to a thin liquid film adjacent to a horizontal rotating disk. The film is formed by the impingement of a controlled liquid jet at the center of the disk and subsequent radial spreading of liquid along the disk. The chemical reaction between the gas and the liquid film can be expressed as a zero-order homogeneous reaction. The process was modeled by establishing equations for the conservation of mass, momentum, and species concentration and solving them analytically. A scaling analysis was used to determine dominant transport processes. Appropriate boundary conditions were used to solve these equations to develop expressions for the local concentration of gas across the thickness of the film and distributions of film height, bulk concentration, and Sherwood number along the radius of the disk. The partial differential equation for species concentration was solved using the separation of variables technique along with the Duhamel's theorem and the final analytical solution was expressed using confluent hypergeometric functions. Tables for eigenvalues and eigenfunctions are presented for a number of reaction rate constants. A parametric study was performed using Reynolds number, Ekman number, and dimensionless reaction rate as parameters. At all radial locations, Sherwood number increased with Reynolds number (flow rate) as well as Ekman number (rate of rotation). The enhancement of mass transfer due to chemical reaction was found to be small when compared to the case of no reaction (pure absorption), but the enhancement factor was very significant when compared to pure absorption in a stagnant liquid film. The zero-order reaction processes considered in the present investigation included the absorption of oxygen in aqueous alkaline solutions of sodiumdithionite and rhodium complex catalyzed carbonylation of methanol. Present analytical results were compared to previous theoretical

  19. High-throughput liquid-absorption air-sampling apparatus and methods

    Science.gov (United States)

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is 20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  20. High-throughput liquid-absorption air-sampling apparatus and methods

    International Nuclear Information System (INIS)

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives

  1. Pressure sensor for high-temperature liquids

    International Nuclear Information System (INIS)

    Forster, G.A.

    1978-01-01

    A pressure sensor for use in measuring pressures in liquid at high temperatures, especially such as liquid sodium or liquid potassium, comprises a soft diaphragm in contact with the liquid. The soft diaphragm is coupled mechanically to a stiff diaphragm. Pressure is measured by measuring the displacement of both diaphragms, typically by measuring the capacitance between the stiff diaphragm and a fixed plate when the stiff diaphragm is deflected in response to the measured pressure through mechanical coupling from the soft diaphragm. Absolute calibration is achieved by admitting gas under pressure to the region between diaphragms and to the region between the stiff diaphragm and the fixed plate, breaking the coupling between the soft and stiff diaphragms. The apparatus can be calibrated rapidly and absolutely

  2. Temperature and emissivity determination of liquid steel S235

    Science.gov (United States)

    Schöpp, H.; Sperl, A.; Kozakov, R.; Gött, G.; Uhrlandt, D.; Wilhelm, G.

    2012-06-01

    Temperature determination of liquid metals is difficult but a necessary tool for improving materials and processes such as arc welding in the metal-working industry. A method to determine the surface temperature of the weld pool is described. A TIG welding process and absolute calibrated optical emission spectroscopy are used. This method is combined with high-speed photography. 2D temperature profiles are obtained. The emissivity of the radiating surface has an important influence on the temperature determination. A temperature dependent emissivity for liquid steel is given for the spectral region between 650 and 850 nm.

  3. Temperature and emissivity determination of liquid steel S235

    International Nuclear Information System (INIS)

    Schöpp, H; Kozakov, R; Gött, G; Uhrlandt, D; Sperl, A; Wilhelm, G

    2012-01-01

    Temperature determination of liquid metals is difficult but a necessary tool for improving materials and processes such as arc welding in the metal-working industry. A method to determine the surface temperature of the weld pool is described. A TIG welding process and absolute calibrated optical emission spectroscopy are used. This method is combined with high-speed photography. 2D temperature profiles are obtained. The emissivity of the radiating surface has an important influence on the temperature determination. A temperature dependent emissivity for liquid steel is given for the spectral region between 650 and 850 nm. (paper)

  4. Efficient removal of H2S at high temperature using the ionic liquid solutions of [C4mim]3PMo12O40-An organic polyoxometalate.

    Science.gov (United States)

    Ma, Yunqian; Liu, Xinpeng; Wang, Rui

    2017-06-05

    An innovative approach to H 2 S capture and sulfur recovery via liquid redox at high temperature has been developed using [C 4 mim] 3 PMo 12 O 40 at temperatures ranging from 80 to 180°C, which is superior to the conventional water-based system with an upper limit of working temperature normally below 60°C. The ionic liquids used as solvents include [C 4 mim]Cl, [C 4 mim]BF 4 , [C 4 mim]PF 6 and [C 4 mim]NTf 2 . Microscopic observation and turbidity measurement were used to investigate the dissolution of [C 4 mim] 3 PMo 12 O 40 in the ionic liquids. Stabilization energy between H 2 S and the anion of ionic liquid as well as H 2 O was calculated to illustrate the interaction between H 2 S and the solvents. The cavity theory can be adopted to illustrate the mechanism for H 2 S absorption: the Cl - ion with small radius can be incorporated into the cavities of [C 4 mim] 3 PMo 12 O 40 , and interact with H 2 S strongly. The underlying mechanism for sulfur formation is the redox reaction between H 2 S and PMo 12 O 40 3- . H 2 S can be oxidized to elemental sulfur and Mo 6+ is partly reduced during absorption, according to UV-vis and FTIR spectra. The [C 4 mim] 3 PMo 12 O 40 -[C 4 mim]Cl after reaction can be readily regenerated by air and thus enabling its efficient and repeatitive use. The absorbent of [C 4 mim] 3 PMo 12 O 40 -ionic liquid system provides a new approach for wet oxidation desulfurization at high temperature. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Performance of a LiBr water absorption chiller operating with plate heat exchangers

    OpenAIRE

    Vega Blázquez, Mercedes de; Almendros Ibáñez, José Antonio; Ruiz, G.

    2006-01-01

    This paper studies the performance of a lithium bromide water absorption chiller operating with plate heat exchangers (PHE). The overall heat transfer coefficients in the desorber, the condenser and the solution heat recoverer are calculated using the correlations provided in the literature for evaporation, condensation and liquid to liquid heat transfer in PHEs. The variable parameters are the external driving temperatures. In the desorber, the inlet temperature of the hot fluid ranges from ...

  6. Pumping liquid metal at high temperatures up to 1,673 kelvin

    Science.gov (United States)

    Amy, C.; Budenstein, D.; Bagepalli, M.; England, D.; Deangelis, F.; Wilk, G.; Jarrett, C.; Kelsall, C.; Hirschey, J.; Wen, H.; Chavan, A.; Gilleland, B.; Yuan, C.; Chueh, W. C.; Sandhage, K. H.; Kawajiri, Y.; Henry, A.

    2017-10-01

    Heat is fundamental to power generation and many industrial processes, and is most useful at high temperatures because it can be converted more efficiently to other types of energy. However, efficient transportation, storage and conversion of heat at extreme temperatures (more than about 1,300 kelvin) is impractical for many applications. Liquid metals can be very effective media for transferring heat at high temperatures, but liquid-metal pumping has been limited by the corrosion of metal infrastructures. Here we demonstrate a ceramic, mechanical pump that can be used to continuously circulate liquid tin at temperatures of around 1,473-1,673 kelvin. Our approach to liquid-metal pumping is enabled by the use of ceramics for the mechanical and sealing components, but owing to the brittle nature of ceramics their use requires careful engineering. Our set-up enables effective heat transfer using a liquid at previously unattainable temperatures, and could be used for thermal storage and transport, electric power production, and chemical or materials processing.

  7. Effect of environmental temperature on shock absorption properties of running shoes.

    Science.gov (United States)

    Dib, Mansour Y; Smith, Jay; Bernhardt, Kathie A; Kaufman, Kenton R; Miles, Kevin A

    2005-05-01

    To determine the effect of temperature changes on the shock attenuation of 4 running shoe shock absorption systems. Prospective. Motion analysis laboratory. The shock attenuation of 4 different running shoes representing common shock absorption systems (Nike Air Triax, Asics Gel Nimbus IV, Adidas a3 cushioning, Adidas Supernova cushion) was measured at ambient temperatures of -20 degrees C, -10 degrees C, 0 degrees C, +10 degrees C, +20 degrees C, +30 degrees C, +40 degrees C, and +50 degrees C. Repeated-measures analysis of variance was used to determine differences between shoes. Shock attenuation as indicated by peak deceleration (g) measured by a mechanical impactor following ASTM Standard F1614-99. Shock attenuation decreased significantly with reduced temperature for each shoe tested. The Adidas a3 shoe exhibited significantly higher peak decelerations (lower shock attenuation) at cold temperatures compared with the other shoes. Cold ambient temperatures significantly reduce the shock attenuation of commonly used running shoes. These findings have important clinical implications for individuals training in extreme weather environments, particularly those with a history of lower limb overuse injuries.

  8. Absorption of high-frequency electromagnetic energy in a high-temperature plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sagdeyev, R S; Shafranov, V D

    1958-07-01

    In this paper an analysis of the cyclotron and Cherenkov mechanisms is given. These are two fundamental mechanisms for noncollisional absorption of electromagnetic radiation by plasma in a magnetic field. The expressions for the dielectric permeability tensor, for plasma with a nonisotropic temperature distribution in a magnetic field, are obtained by integrating the kinetic equation with Lagrangian particle co-ordinates in a form suitable to allow a comprehensive physical interpretation of the absorption mechanisms. The oscillations of a plasma column stabilized by a longitudinal field have been analyzed. For uniform plasma, the frequency spectrum has been obtained together with the direction of electromagnetic wave propagation when both the cyclotron and Cherenkov absorption mechanisms take place. The influence of nonlinear effects on the electromagnetic wave absorption and the part which cyclotron and Cherenkov absorption play in plasma heating have also been investigated.

  9. Absorption of carbon dioxide in aqueous solutions of imidazolium ionic liquids with carboxylate anions

    International Nuclear Information System (INIS)

    Baj, Stefan; Krawczyk, Tomasz; Dabrowska, Aleksandra; Siewniak, Agnieszka; Sobolewski, Aleksander

    2015-01-01

    The solubility of carbon dioxide at atmospheric pressure in aqueous mixtures of 1,3-alkyl substituted imidazolium ionic liquids (ILs) containing carboxylic anions was studied. The ILs showed increased solubility of CO 2 with decreasing water concentration. The relationship between the CO 2 concentration in solution and the mole fraction of water in the ILs describes a sigmoidal curve. The regression constants of a logistic function were used to quantitatively assess the absorbent capacity and the effect of water on CO 2 absorption. ILs containing the most basic anions, such as pivalate, propionate and acetate, had the best properties. It was observed that the impact of water on absorption primarily depended on the cation structure. The best absorption performance was observed for 1,3-dibutylimidazolium pivalate and 1-butyl-3-methyl imidazolium acetate.

  10. Absorption of scintillation light in a 100l liquid xenon γ-ray detector and expected detector performance

    International Nuclear Information System (INIS)

    Baldini, A.; Bemporad, C.; Cei, F.; Doke, T.; Grassi, M.; Grebenuk, A.A.; Grigoriev, D.N.; Haruyama, T.; Kasami, K.; Kikuchi, J.; Maki, A.; Mashimo, T.; Mihara, S.; Mitsuhashi, T.; Mori, T.; Nicolo, D.; Nishiguchi, H.; Ootani, W.; Ozone, K.; Papa, A.; Pazzi, R.; Ritt, S.; Sawada, R.; Sergiampietri, F.; Signorelli, G.; Suzuki, S.; Terasawa, K.; Yamashita, M.; Yamashita, S.; Yoshimura, T.; Yuri, Yu.

    2005-01-01

    An 800l liquid xenon scintillation γ-ray detector is being developed for the MEG experiment which will search for μ + ->e + γdecay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100l prototype with an active volume of 372x372x496mm 3 to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and α sources. By using a suitable purification technique, an absorption length longer than 100cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation

  11. Temperature dependence of microwave absorption phenomena in single and biphase soft magnetic microwires

    Energy Technology Data Exchange (ETDEWEB)

    El Kammouni, Rhimou, E-mail: elkammounirhimou@gmail.com [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Vázquez, Manuel [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Lezama, Luis [Depto. Química Inorgánica, Universidad País Vasco, UPV/EHU, Bilbao (Spain); Kurlyandskaya, Galina [Depto. Electricidad y Electrónica, Universidad País Vasco, UPV/EHU, Bilbao (Spain); Dept. Magnetism and Magnetic Nanomaterials, Ural Federal University, Ekaterinburg (Russian Federation); Kraus, Ludek [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic)

    2014-11-15

    The microwave absorption phenomena of single and biphase magnetic microwires with soft magnetic behavior have been investigated as a function of DC applied magnetic field using two alternative techniques: (i) absorption measurements in the temperature range of 4–300 K using a spectrometer operating at X-band frequency, at 9.5 GHz, and (ii) room-temperature, RT, ferromagnetic resonance measurements in a network analyzer in the frequency range up to 20 GHz. Complementary low-frequency magnetic characterization was performed in a Vibrating Sample Magnetometer. Studies have been performed for 8 μm diameter small-magnetostriction amorphous CoFeSiB single-phase microwire, coated by micrometric Pyrex layer, and after electroplating an external shell, 2 µm or 4 µm thick, of FeNi alloys. For single phase CoFeSiB microwire, a single absorption is observed, whose DC field dependence of resonance frequency at RT fits to a Kittel-law behavior for in-plane magnetized thin film. The temperature dependence behavior shows a monotonic increase in the resonance field, H{sub r}, with temperature. A parallel reduction of the circular anisotropy field, H{sub K}, is deduced from the temperature dependence of hysteresis loops. For biphase, CoFeSiB/FeNi, microwires, the absorption phenomena at RT also follow the Kittel condition. The observed opposite evolution with temperature of resonance field, H{sub r}, in 2 and 4 µm thick FeNi samples is interpreted considering the opposite sign of magnetostriction of the respective FeNi layers. The stress-induced magnetic anisotropy field, H{sub K}, in the FeNi shell is deduced to change sign at around 130 K. - Highlights: • A single absorption phenomenon is observed for single phase CoFeSiB. • The T dependence of the microwave behavior shows a monotonic increase of H{sub r} with T. • The absorption at RT follows the Kittel condition for biphase CoFe/FeNi microwires. • The T dependence of resonant field of CoFe/FeNi is interpreted to be

  12. Enabling liquid solvent structure analysis using hard x-ray absorption spectroscopy with a transferrable microfluidic reactor

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jian; Zhang, Wei; Wang, Feng; Yu, Xiao-Ying

    2018-04-11

    In this paper, a vacuum compatible microfluidic device, System for Analysis at the Liquid Vacuum Interface (SALVI), is integrated to hard x-ray absorption spectroscopy (XAS) to obtain the local structure of K3[Fe(CN)6] in aqueous solutions with three concentrations of 0.5 M, 0.05 M, and 0.005 M. The solutions were sealed in a microchannel of 500 μm wide and 300 µm deep in a portable microfluidic device. The Fe K-edge x-ray absorption spectra show that the complex in water is Fe(III). The complex is present with octahedral geometry coordinated with 6 C atoms in the first shell with a distance of ~1.92 Å and 6 N atoms in the second shell with a distance of ~3.10 Å. Varying the concentration has no observable influence on the structure of K3[Fe(CN)6]. Our results demonstrate the feasibility of using microfluidic based liquid cells in large synchrotron facilities and it is a viable approach to enable multifaceted measurements of liquids in the future.

  13. Enabling liquid solvent structure analysis using hard x-ray absorption spectroscopy with a transferrable microfluidic reactor

    Science.gov (United States)

    Zheng, Jian; Zhang, Wei; Wang, Feng; Yu, Xiao-Ying

    2018-05-01

    In this paper, a vacuum compatible microfluidic device, system for analysis at the liquid vacuum interface, is integrated to hard x-ray absorption spectroscopy to obtain the local structure of K3[Fe(CN)6] in aqueous solutions with three concentrations of 0.5 M, 0.05 M, and 0.005 M. The solutions were sealed in a microchannel 500 µm wide and 300 µm deep in a portable microfluidic device. The Fe K-edge x-ray absorption spectra indicate a presence of Fe(III) in the complex in water, with an octahedral geometry coordinated with 6 C atoms in the first shell with a distance of ~1.92 Å and 6 N atoms in the second shell with a distance of ~3.10 Å. Varying the concentration has no observable influence on the structure of K3[Fe(CN)6]. Our results demonstrate the feasibility of using microfluidic based liquid cells in large synchrotron facilities. Using portable microfludic reactors provides a viable approach to enable multifaceted measurements of liquids in the future.

  14. Influence of Gas-Liquid Interface on Temperature Wave of Pulsating Heat Pipe

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    2018-01-01

    Full Text Available The influence of the interface on the amplitude and phase of the temperature wave and the relationship between the attenuation of the temperature wave and the gas-liquid two-phase physical parameters are studied during the operation of the pulsating heat pipe. The numerical simulation shows that the existence of the phase interface changes the direction of the temperature gradient during the propagation of the temperature wave, which increases the additional “thermal resistance.” The relative size of the gas-liquid two-phase thermal conductivity affects the propagation direction of heat flow at phase interface directly. The blockage of the gas plug causes hysteresis in the phase of the temperature wave, the relative size of the gas-liquid two-phase temperature coefficient will gradually increase the phase of the temperature wave, and the time when the heat flow reaches the peak value is also advanced. The attenuation of the temperature wave is almost irrelevant to the absolute value of the density, heat capacity, and thermal conductivity of the gas-liquid two phases, and the ratio of the thermal conductivity of the gas-liquid two phases is related. When the temperature of the heat pipe was changed, the difference of heat storage ability between gas and liquid will lead to the phenomenon of heat reflux and becomes more pronounced with the increases of the temperature wave.

  15. Methylmercury determination using a hyphenated high performance liquid chromatography ultraviolet cold vapor multipath atomic absorption spectrometry system

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Reinaldo C. [Department of Chemistry, Pontifical Catholic University of Rio de Janeiro, Rua Marques de S Vicente 225, 22453-900 Rio de Janeiro (Brazil)], E-mail: rccampos@puc-rio.br; Goncalves, Rodrigo A.; Brandao, Geisamanda P.; Azevedo, Marlo S. [Department of Chemistry, Pontifical Catholic University of Rio de Janeiro, Rua Marques de S Vicente 225, 22453-900 Rio de Janeiro (Brazil); Oliveira, Fabiana; Wasserman, Julio [Institut of Geosciences, Fluminense Federal University, Av. Gal. Milton Tavares de Souza, s/n, 24.210-340, Niteroi, Rio de Janeiro (Brazil)

    2009-06-15

    The present work investigates the use of a multipath cell atomic absorption mercury detector for mercury speciation analysis in a hyphenated high performance liquid chromatography assembly. The multipath absorption cell multiplies the optical path while energy losses are compensated by a very intense primary source. Zeeman-effect background correction compensates for non-specific absorption. For the separation step, the mobile phase consisted in a 0.010% m/v mercaptoethanol solution in 5% methanol (pH = 5), a C{sub 18} column was used as stationary phase, and post column treatment was performed by UV irradiation (60 deg. C, 13 W). The eluate was then merged with 3 mol L{sup -1} HCl, reduction was performed by a NaBH{sub 4} solution, and the Hg vapor formed was separated at the gas-liquid separator and carried through a desiccant membrane to the detector. The detector was easily attached to the system, since an external gas flow to the gas-liquid separator was provided. A multivariate approach was used to optimize the procedure and peak area was used for measurement. Instrumental limits of detection of 0.05 {mu}g L{sup -1} were obtained for ionic (Hg{sup 2+}) and HgCH{sub 3}{sup +}, for an injection volume of 200 {mu}L. The multipath atomic absorption spectrometer proved to be a competitive mercury detector in hyphenated systems in relation to the most commonly used atomic fluorescence and inductively coupled plasma mass spectrometric detectors. Preliminary application studies were performed for the determination of methyl mercury in sedi0011men.

  16. Methylmercury determination using a hyphenated high performance liquid chromatography ultraviolet cold vapor multipath atomic absorption spectrometry system

    International Nuclear Information System (INIS)

    Campos, Reinaldo C.; Goncalves, Rodrigo A.; Brandao, Geisamanda P.; Azevedo, Marlo S.; Oliveira, Fabiana; Wasserman, Julio

    2009-01-01

    The present work investigates the use of a multipath cell atomic absorption mercury detector for mercury speciation analysis in a hyphenated high performance liquid chromatography assembly. The multipath absorption cell multiplies the optical path while energy losses are compensated by a very intense primary source. Zeeman-effect background correction compensates for non-specific absorption. For the separation step, the mobile phase consisted in a 0.010% m/v mercaptoethanol solution in 5% methanol (pH = 5), a C 18 column was used as stationary phase, and post column treatment was performed by UV irradiation (60 deg. C, 13 W). The eluate was then merged with 3 mol L -1 HCl, reduction was performed by a NaBH 4 solution, and the Hg vapor formed was separated at the gas-liquid separator and carried through a desiccant membrane to the detector. The detector was easily attached to the system, since an external gas flow to the gas-liquid separator was provided. A multivariate approach was used to optimize the procedure and peak area was used for measurement. Instrumental limits of detection of 0.05 μg L -1 were obtained for ionic (Hg 2+ ) and HgCH 3 + , for an injection volume of 200 μL. The multipath atomic absorption spectrometer proved to be a competitive mercury detector in hyphenated systems in relation to the most commonly used atomic fluorescence and inductively coupled plasma mass spectrometric detectors. Preliminary application studies were performed for the determination of methyl mercury in sediments.

  17. Time-dependent radiolytic yields at room temperature and temperature-dependent absorption spectra of the solvated electrons in polyols

    International Nuclear Information System (INIS)

    Lin Mingzhang; Mostafavi, M.; Lampre, I.; Muroya, Y.; Katsumura, Y.

    2007-01-01

    The molar extinction coefficients at the absorption maximum of the solvated electron spectrum have been evaluated to be 900, 970, and 1000 mol -1 ·m 2 for 1,2-ethanediol (12ED), 1,2-propanediol (12PD), and 1,3-propanediol (13PD), respectively. These values are two-third or three-fourth of the value usually reported in the published report. Picosecond pulse radiolysis studies have aided in depicting the radiolytic yield of the solvated electron in these solvents as a function of time from picosecond to microsecond. The radiolytic yield in these viscous solvents is found to be strongly different from that of the water solution. The temperature dependent absorption spectra of the solvated electron in 12ED, 12PD, and 13PD have been also investigated. In all the three solvents, the optical spectra shift to the red with increasing temperature. While the shape of the spectra does not change in 13PD, a widening on the blue side of the absorption band is observed in 12ED and 12PD at elevated temperatures. (authors)

  18. Solution processing of polymer semiconductor: Insulator blends-Tailored optical properties through liquid-liquid phase separation control

    KAUST Repository

    Hellmann, Christoph; Treat, Neil D.; Scaccabarozzi, Alberto D.; Razzell Hollis, Joseph; Fleischli, Franziska D.; Bannock, James H.; de Mello, John; Michels, Jasper J.; Kim, Ji-Seon; Stingelin, Natalie

    2014-01-01

    © 2014 Wiley Periodicals, Inc. It has been demonstrated that the 0-0 absorption transition of poly(3-hexylthiophene) (P3HT) in blends with poly(ethylene oxide) (PEO) could be rationally tuned through the control of the liquid-liquid phase separation process during solution deposition. Pronounced J-like aggregation behavior, characteristic for systems of a low exciton band width, was found for blends where the most pronounced liquid-liquid phase separation occurred in solution, leading to domains of P3HT and PEO of high phase purity. Since liquid-liquid phase separation could be readily manipulated either by the solution temperature, solute concentration, or deposition temperature, to name a few parameters, our findings promise the design from the out-set of semiconductor:insulator architectures of pre-defined properties by manipulation of the interaction parameter between the solutes as well as the respective solute:solvent system using classical polymer science principles.

  19. Solution processing of polymer semiconductor: Insulator blends-Tailored optical properties through liquid-liquid phase separation control

    KAUST Repository

    Hellmann, Christoph

    2014-12-17

    © 2014 Wiley Periodicals, Inc. It has been demonstrated that the 0-0 absorption transition of poly(3-hexylthiophene) (P3HT) in blends with poly(ethylene oxide) (PEO) could be rationally tuned through the control of the liquid-liquid phase separation process during solution deposition. Pronounced J-like aggregation behavior, characteristic for systems of a low exciton band width, was found for blends where the most pronounced liquid-liquid phase separation occurred in solution, leading to domains of P3HT and PEO of high phase purity. Since liquid-liquid phase separation could be readily manipulated either by the solution temperature, solute concentration, or deposition temperature, to name a few parameters, our findings promise the design from the out-set of semiconductor:insulator architectures of pre-defined properties by manipulation of the interaction parameter between the solutes as well as the respective solute:solvent system using classical polymer science principles.

  20. Chromatographic determination of the rate and extent of absorption of air pollutants by sea water

    International Nuclear Information System (INIS)

    Nikolakaki, S.; Vassilakos, C.; Katsanos, N.A.

    1994-01-01

    A simple chromatographic method is developed to determine the rate constant for expulsion of an air pollutant from water or its diffusion parameter in the liquid, the rate constant for chemical reaction of the pollutant with water, its mass transfer coefficient in the liquid, and the partition coefficient between liquid water and air. From these physicochemical parameters, the absorption rate by sea water and, therefore, the depletion rate of a polluting substance from the air can be calculated, together with the equilibrium state of this absorption. The method has been applied to nitrogen dioxide being absorbed by triple-distilled water and by sea water, at various temperatures. From the temperature variation of the reaction rate constant and of the partition coefficient, the activation energy for the reaction and the differential heat of solution were determined. (orig.)

  1. High-throughput liquid-absorption air-sampling apparatus and methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-11

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is < 10 cm of water, usually < 5 cm of water. The sampler's collection efficiency is usually > 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  2. Novel separation process of gaseous mixture of SO2 and O2 with ionic liquid for hydrogen production in thermochemical sulfur-iodine water splitting cycle

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Gong, Gyeong Taek; Yoo, Kye Sang; Kim, Honggon; Lee, Byoung Gwon; Ahn, Byoung Sung; Jung, Kwang Deog; Lee, Ki Yong; Song, Kwang Ho

    2007-01-01

    Sulfur-Iodine cycle is the most promising thermochemical cycle for water splitting to produce hydrogen which can replace the fossil fuels in the future. As a sub-cycle in the thermochemical Sulfur-Iodine water splitting cycle, sulfuric acid (H 2 SO 4 ) decomposes into oxygen (O 2 ) and sulfur dioxide (SO 2 ) which should be separated for the recycle of SO 2 into the sulfuric acid generation reaction (Bunsen Reaction). In this study, absorption and desorption process of SO 2 by ionic liquid which is useful for the recycle of SO 2 into sulfuric acid generation reaction after sulfuric acid decomposition in the thermochemical Sulfur-Iodine cycle is investigated. At first, the operability as an absorbent for the SO 2 absorption and desorption at high temperature without the volatilization of absorbents which is not suitable for the recycle of absorbent-free SO 2 after the absorption process. The temperature range of operability is determined by TGA and DTA analysis. Most of ionic liquids investigated are applicable at high temperature desorption without volatility around 300 deg. C except [BMIm] Cl, and [BMIm] OAc which show the decomposition of ionic liquids. To evaluate the capability of SO 2 absorption, each ionic liquid is located in the absorption tube and gaseous SO 2 is bubbled into the ionic liquid. During the bubbling, the weight of the system is measured and converted into the absorbed SO 2 amount at each temperature controlled by the heater. Saturated amounts of absorbed SO 2 by ionic liquids at 50 deg. C are presented. The effect of anions for the SO 2 absorption capability is shown in the order of Cl, OAc, MeSO 3 , BF 4 , MeSO 4 , PF 6 , and HSO 4 when they are combined with [BMIm] cation. [BMIm]Cl has the largest amount of SO 2 absorbed which can be the most promising absorbent; however, from the point of operability at high temperature which includes desorption process, [BMIm]Cl is vulnerable to high temperature around 250 deg. C based on the TGA

  3. Absorption of carbon dioxide in aqueous solutions of imidazolium ionic liquids with carboxylate anions

    Energy Technology Data Exchange (ETDEWEB)

    Baj, Stefan; Krawczyk, Tomasz; Dabrowska, Aleksandra; Siewniak, Agnieszka [Silesian University of Technology, Gliwice (Poland); Sobolewski, Aleksander [Institute for Chemical Processing of Coal, Zabrze (Poland)

    2015-11-15

    The solubility of carbon dioxide at atmospheric pressure in aqueous mixtures of 1,3-alkyl substituted imidazolium ionic liquids (ILs) containing carboxylic anions was studied. The ILs showed increased solubility of CO{sub 2} with decreasing water concentration. The relationship between the CO{sub 2} concentration in solution and the mole fraction of water in the ILs describes a sigmoidal curve. The regression constants of a logistic function were used to quantitatively assess the absorbent capacity and the effect of water on CO{sub 2} absorption. ILs containing the most basic anions, such as pivalate, propionate and acetate, had the best properties. It was observed that the impact of water on absorption primarily depended on the cation structure. The best absorption performance was observed for 1,3-dibutylimidazolium pivalate and 1-butyl-3-methyl imidazolium acetate.

  4. Molecular Dynamics Simulations of Liquid Phosphorus at High Temperature and Pressure

    International Nuclear Information System (INIS)

    Wu Yanning; Zhao Gang; Liu Changsong; Zhu Zhengang

    2008-01-01

    By performing ab initio molecular dynamics simulations, we have investigated the microstructure, dynamical and electronic properties of liquid phosphorus (P) under high temperature and pressure. In our simulations, the calculated coordination number (CN) changes discontinuously with density, and seems to increase rapidly after liquid P is compressed to 2.5 g/cm 3 . Under compression, liquid P shows the first-order liquid-liquid phase transition from the molecular liquid composed of the tetrahedral P 4 molecules to complex polymeric form with three-dimensional network structure, accompanied by the nonmetal to metal transition of the electronic structure. The order parameters Q 6 and Q 4 are sensitive to the microstructural change of liquid P. By calculating diffusion coefficients, we show the dynamical anomaly of liquid P by compression. At lower temperatures, a maximum exists at the diffusion coefficients as a function of density; at higher temperatures, the anomalous behavior is weakened. The excess entropy shows the same phenomena as the diffusion coefficients. By analysis of the angle distribution functions and angular limited triplet correlation functions, we can clearly find that the Peierls distortion in polymeric form of liquid P is reduced by further compression

  5. (Liquid + liquid) equilibrium of (dibutyl ether + methanol + water) at different temperatures

    International Nuclear Information System (INIS)

    Arce, Alberto; Rodriguez, Hector; Rodriguez, Oscar; Soto, Ana

    2005-01-01

    (Liquid + liquid) equilibrium data for the ternary system (dibutyl ether + methanol + water) were experimentally determined at T = (298.15, 308.15, and 318.15) K. The experimental results were correlated by means of the NRTL and UNIQUAC equations, the best results being achieved with the UNIQUAC equation, both for the individual correlations at each temperature and for the overall correlation considering all the three experimental data sets. The experimental tie-lines were also compared to the values predicted by the UNIFAC method

  6. Volatility of coal liquids at high temperatures and pressures

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, G M; Johnston, R H; Hwang, S C; Tsonopoulos, C

    1981-01-01

    The volatility of coal liquids has been experimentally determined at 700-880 F and about 2000 psia. These measurements were made in a flow apparatus to minimize thermal decomposition effects at high temperatures. Three coal liquids in mixture with Hat2, methane, and Hat2S were investigated. Measurements were also made up to 900 F on the vapor pressure of pure compounds found in coal liquids and on the equilibrium pressure of narrow coal liquid cuts. These data were used to develop a new method for the prediction of the critical point and the superatmospheric vapour pressures of aromatic fractions that is superior to the Maxwell-Bonnell correlation. The VLE data on coal liquids and some recent high-temperature VLE data on binaries of aromatics with Hat2 or methane were analyzed with a modified Chao-Seader correlation and a modified Redlich-Kwong equation of state. Both VLE correlations are shown to be equivalent in the prediction of the volatility of coal liquids, when the new vapour pressure procedure is used.

  7. Time-temperature superposition in viscous liquids

    DEFF Research Database (Denmark)

    Olsen, Niels Boye; Dyre, Jeppe; Christensen, Tage Emil

    2001-01-01

    with a reduced time definition based on a recently proposed expression for the relaxation time, where G [infinity] reflects the fictive temperature. All parameters entering the reduced time were determined from independent measurements of the frequency-dependent shear modulus of the equilibrium liquid....

  8. Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

    Science.gov (United States)

    Browell, Edward V.; Ismail, Syed; Grossmann, Benoist E.

    1991-01-01

    Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

  9. Liquid structure and temperature invariance of sound velocity in supercooled Bi melt

    International Nuclear Information System (INIS)

    Emuna, M.; Mayo, M.; Makov, G.; Greenberg, Y.; Caspi, E. N.; Yahel, E.; Beuneu, B.

    2014-01-01

    Structural rearrangement of liquid Bi in the vicinity of the melting point has been proposed due to the unique temperature invariant sound velocity observed above the melting temperature, the low symmetry of Bi in the solid phase and the necessity of overheating to achieve supercooling. The existence of this structural rearrangement is examined by measurements on supercooled Bi. The sound velocity of liquid Bi was measured into the supercooled region to high accuracy and it was found to be invariant over a temperature range of ∼60°, from 35° above the melting point to ∼25° into the supercooled region. The structural origin of this phenomenon was explored by neutron diffraction structural measurements in the supercooled temperature range. These measurements indicate a continuous modification of the short range order in the melt. The structure of the liquid is analyzed within a quasi-crystalline model and is found to evolve continuously, similar to other known liquid pnictide systems. The results are discussed in the context of two competing hypotheses proposed to explain properties of liquid Bi near the melting: (i) liquid bismuth undergoes a structural rearrangement slightly above melting and (ii) liquid Bi exhibits a broad maximum in the sound velocity located incidentally at the melting temperature

  10. Temperature dependence on mutual solubility of binary (methanol + limonene) mixture and (liquid + liquid) equilibria of ternary (methanol + ethanol + limonene) mixture

    International Nuclear Information System (INIS)

    Tamura, Kazuhiro; Li Xiaoli; Li Hengde

    2009-01-01

    Mutual solubility data of the binary (methanol + limonene) mixture at the temperatures ranging from 288.15 K close to upper critical solution temperature, and ternary (liquid + liquid) equilibrium (tie-lines) of the (methanol + ethanol + limonene) mixture at the temperatures (288.15, 298.15, and 308.15) K have been obtained. The experimental results have been represented accurately in terms of the extended and modified UNIQUAC models with binary parameters, compared with the UNIQUAC model. The temperature dependence of binary and ternary (liquid + liquid) equilibrium for the binary (methanol + limonene) and ternary (methanol + ethanol + limonene) mixtures could be calculated successfully using the extended and modified UNIQUAC model

  11. Structure and morphologies of ZnO nanoparticles synthesized by pulsed laser ablation in liquid: Effects of temperature and energy fluence

    Energy Technology Data Exchange (ETDEWEB)

    Guillén, G. García; Palma, M.I. Mendivil [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455 (Mexico); Krishnan, B. [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455 (Mexico); Universidad Autónoma de Nuevo León – Centro de Innovación, Investigación y Desarrollo de Ingeniería y Tecnología, Apodaca, Nuevo León 66600 (Mexico); Avellaneda, D.; Castillo, G.A.; Roy, T.K. Das [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455 (Mexico); and others

    2015-07-15

    Zinc oxide nanoparticles were prepared by pulsed laser ablation of a zinc metal target at different water temperatures (room temperature, 50, 70 and 90 °C). Ablation was carried out using 532 nm output from a pulsed (10 ns, 10 Hz) Nd:YAG laser at three different laser fluence. Analysis of the morphology, crystalline phase, elemental composition, optical and luminescent properties were done using Transmission Electron Microscopy (TEM), X-Ray Photoelectron Spectroscopy (XPS), UV–visible absorption spectroscopy and photoluminescence spectroscopy. TEM analysis showed that a change in temperature resulted in ZnO and Zn(OH){sub 2} nanoparticles with different sizes and morphologies. XPS results confirmed the compositions and chemical states of these nanoparticles. These zinc nanomaterials showed emission in the ultraviolet (UV) and blue regions. The results of this work demonstrated that by varying the liquid medium temperature, the structure, composition, morphology and optical properties of the nanomaterials could be modified during pulsed laser ablation in liquid. - Graphical abstract: Display Omitted - Highlights: • Zinc nanomaterial colloids were synthesized by PLAL. • Effects of laser fluence and the distilled water temperature were analyzed. • The final structure varied with the distilled water temperature and laser fluence. • The morphology was dependent on the distilled water temperature and laser fluence. • Zinc nanocolloids showed emission in the UV and blue region.

  12. Structure and morphologies of ZnO nanoparticles synthesized by pulsed laser ablation in liquid: Effects of temperature and energy fluence

    International Nuclear Information System (INIS)

    Guillén, G. García; Palma, M.I. Mendivil; Krishnan, B.; Avellaneda, D.; Castillo, G.A.; Roy, T.K. Das

    2015-01-01

    Zinc oxide nanoparticles were prepared by pulsed laser ablation of a zinc metal target at different water temperatures (room temperature, 50, 70 and 90 °C). Ablation was carried out using 532 nm output from a pulsed (10 ns, 10 Hz) Nd:YAG laser at three different laser fluence. Analysis of the morphology, crystalline phase, elemental composition, optical and luminescent properties were done using Transmission Electron Microscopy (TEM), X-Ray Photoelectron Spectroscopy (XPS), UV–visible absorption spectroscopy and photoluminescence spectroscopy. TEM analysis showed that a change in temperature resulted in ZnO and Zn(OH) 2 nanoparticles with different sizes and morphologies. XPS results confirmed the compositions and chemical states of these nanoparticles. These zinc nanomaterials showed emission in the ultraviolet (UV) and blue regions. The results of this work demonstrated that by varying the liquid medium temperature, the structure, composition, morphology and optical properties of the nanomaterials could be modified during pulsed laser ablation in liquid. - Graphical abstract: Display Omitted - Highlights: • Zinc nanomaterial colloids were synthesized by PLAL. • Effects of laser fluence and the distilled water temperature were analyzed. • The final structure varied with the distilled water temperature and laser fluence. • The morphology was dependent on the distilled water temperature and laser fluence. • Zinc nanocolloids showed emission in the UV and blue region

  13. Microwave heating behavior and microwave absorption properties of barium titanate at high temperatures

    Directory of Open Access Journals (Sweden)

    K. Kashimura

    2016-06-01

    Full Text Available The temperature dependence of the microwave absorption behavior of BaTiO3 particles was investigated over various frequencies and temperatures of 25-1000 ∘C. First, using both the coaxial transmission line method and the cavity perturbation method by a network analyzer, the real and imaginary parts of the relative permittivity of BaTiO3 ( ε r ′ and ε r ″ , respectively were measured, in order to improve the reliability of the data obtained at 2.45 GHz. The imaginary parts of the relative permittivity as measured by the two methods were explored by their heating behaviors. Furthermore, the temperature dependence of the microwave absorption behavior of BaTiO3 particles was investigated for frequencies of 2.0-13.5 GHz and temperatures of 25-1000 ∘C using the coaxial transmission line method.

  14. Temperature effect on water absorption in an improved periwinkle ...

    African Journals Online (AJOL)

    Studies have been carried out on the water absorption of the improved periwinkle reinforced cement stabilized lateritic bricks. These bricks were produced at different cement to laterite to periwinkle ratio of 1:3:1, 2:3:1, 3:3:1, 3:2:1, 3:1:1, and fired at an elevated temperature of 10000C and 11500C, respectively. From the ...

  15. Pilot absorption experiments with carbonic anhydrase enhanced MDEA

    DEFF Research Database (Denmark)

    Gladis, Arne; F. Lomholdt, Niels; Fosbøl, Philip Loldrup

    2017-01-01

    was determined by both a density method and the BaCl2 method. After the solvent was loaded to equilibrium it was heated up and reintroduced into the column, where CO2 was stripped off using air as stripping gas. The addition of CA increased the mass transfer significantly in all experiments. Lower absorption......Mass transfer experiments were carried out on DTU’s pilot absorber unit, a 10 m high column packed with 250 Y Mellapak structured packing. The influence of temperature, solvent loading, column height and liquid flow rates on absorption performance were determined for a 30 wt% N-methyl...

  16. A new endstation at the Swiss Light Source for ultraviolet photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy measurements of liquid solutions

    International Nuclear Information System (INIS)

    Brown, Matthew A.; Redondo, Amaia Beloqui; Duyckaerts, Nicolas; Mächler, Jean-Pierre; Jordan, Inga; Wörner, Hans Jakob; Lee, Ming-Tao; Ammann, Markus; Nolting, Frithjof; Kleibert, Armin; Huthwelker, Thomas; Birrer, Mario; Honegger, Juri; Wetter, Reto; Bokhoven, Jeroen A. van

    2013-01-01

    A new liquid microjet endstation designed for ultraviolet (UPS) and X-ray (XPS) photoelectron, and partial electron yield X-ray absorption (XAS) spectroscopies at the Swiss Light Source is presented. The new endstation, which is based on a Scienta HiPP-2 R4000 electron spectrometer, is the first liquid microjet endstation capable of operating in vacuum and in ambient pressures up to the equilibrium vapor pressure of liquid water at room temperature. In addition, the Scienta HiPP-2 R4000 energy analyzer of this new endstation allows for XPS measurements up to 7000 eV electron kinetic energy that will enable electronic structure measurements of bulk solutions and buried interfaces from liquid microjet samples. The endstation is designed to operate at the soft X-ray SIM beamline and at the tender X-ray Phoenix beamline. The endstation can also be operated using a Scienta 5 K ultraviolet helium lamp for dedicated UPS measurements at the vapor-liquid interface using either He I or He II α lines. The design concept, first results from UPS, soft X-ray XPS, and partial electron yield XAS measurements, and an outlook to the potential of this endstation are presented

  17. A new endstation at the Swiss Light Source for ultraviolet photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy measurements of liquid solutions.

    Science.gov (United States)

    Brown, Matthew A; Redondo, Amaia Beloqui; Jordan, Inga; Duyckaerts, Nicolas; Lee, Ming-Tao; Ammann, Markus; Nolting, Frithjof; Kleibert, Armin; Huthwelker, Thomas; Müächler, Jean-Pierre; Birrer, Mario; Honegger, Juri; Wetter, Reto; Wörner, Hans Jakob; van Bokhoven, Jeroen A

    2013-07-01

    A new liquid microjet endstation designed for ultraviolet (UPS) and X-ray (XPS) photoelectron, and partial electron yield X-ray absorption (XAS) spectroscopies at the Swiss Light Source is presented. The new endstation, which is based on a Scienta HiPP-2 R4000 electron spectrometer, is the first liquid microjet endstation capable of operating in vacuum and in ambient pressures up to the equilibrium vapor pressure of liquid water at room temperature. In addition, the Scienta HiPP-2 R4000 energy analyzer of this new endstation allows for XPS measurements up to 7000 eV electron kinetic energy that will enable electronic structure measurements of bulk solutions and buried interfaces from liquid microjet samples. The endstation is designed to operate at the soft X-ray SIM beamline and at the tender X-ray Phoenix beamline. The endstation can also be operated using a Scienta 5 K ultraviolet helium lamp for dedicated UPS measurements at the vapor-liquid interface using either He I or He II α lines. The design concept, first results from UPS, soft X-ray XPS, and partial electron yield XAS measurements, and an outlook to the potential of this endstation are presented.

  18. A new endstation at the Swiss Light Source for ultraviolet photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy measurements of liquid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew A.; Redondo, Amaia Beloqui; Duyckaerts, Nicolas; Mächler, Jean-Pierre [Institute for Chemical and Bioengineering, ETH Zürich, CH-8093 Zürich (Switzerland); Jordan, Inga; Wörner, Hans Jakob [Laboratory of Physical Chemistry, ETH Zürich, CH-8093 Zürich (Switzerland); Lee, Ming-Tao; Ammann, Markus; Nolting, Frithjof; Kleibert, Armin; Huthwelker, Thomas; Birrer, Mario; Honegger, Juri; Wetter, Reto [Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland); Bokhoven, Jeroen A. van [Institute for Chemical and Bioengineering, ETH Zürich, CH-8093 Zürich (Switzerland); Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland)

    2013-07-15

    A new liquid microjet endstation designed for ultraviolet (UPS) and X-ray (XPS) photoelectron, and partial electron yield X-ray absorption (XAS) spectroscopies at the Swiss Light Source is presented. The new endstation, which is based on a Scienta HiPP-2 R4000 electron spectrometer, is the first liquid microjet endstation capable of operating in vacuum and in ambient pressures up to the equilibrium vapor pressure of liquid water at room temperature. In addition, the Scienta HiPP-2 R4000 energy analyzer of this new endstation allows for XPS measurements up to 7000 eV electron kinetic energy that will enable electronic structure measurements of bulk solutions and buried interfaces from liquid microjet samples. The endstation is designed to operate at the soft X-ray SIM beamline and at the tender X-ray Phoenix beamline. The endstation can also be operated using a Scienta 5 K ultraviolet helium lamp for dedicated UPS measurements at the vapor-liquid interface using either He I or He II α lines. The design concept, first results from UPS, soft X-ray XPS, and partial electron yield XAS measurements, and an outlook to the potential of this endstation are presented.

  19. VUV-absorption cross section of CO2 at high temperatures and impact on exoplanet atmospheres

    Directory of Open Access Journals (Sweden)

    Venot Olivia

    2014-02-01

    Full Text Available Ultraviolet (UV absorption cross sections are an essential ingredient of photochemical atmosphere models. Exoplanet searches have unveiled a large population of short-period objects with hot atmospheres, very different from what we find in our solar system. Transiting exoplanets whose atmospheres can now be studied by transit spectroscopy receive extremely strong UV fluxes and have typical temperatures ranging from 400 to 2500 K. At these temperatures, UV photolysis cross section data are severely lacking. Our goal is to provide high-temperature absorption cross sections and their temperature dependency for important atmospheric compounds. This study is dedicated to CO2, which is observed and photodissociated in exoplanet atmospheres. We performed these measurements for the 115 - 200 nm range at 300, 410, 480, and 550 K. In the 195 - 230 nm range, we worked at seven temperatures between 465 and 800 K. We found that the absorption cross section of CO2 is very sensitive to temperature, especially above 160 nm. Within the studied range of temperature, the CO2 cross section can vary by more than two orders of magnitude. This, in particular, makes the absorption of CO2 significant up to wavelengths as high as 230 nm, while it is negligible above 200 nm at 300 K. To investigate the influence of these new data on the photochemistry of exoplanets, we implemented the measured cross section into a 1D photochemical model. The model predicts that accounting for this temperature dependency of CO2 cross section can affect the computed abundances of NH3, CO2, and CO by one order of magnitude in the atmospheres of hot Jupiter and hot Neptune.

  20. Performance of iodide vapour absorption in the venturi scrubber working in self-priming mode

    International Nuclear Information System (INIS)

    Zhou, Yanmin; Sun, Zhongning; Gu, Haifeng; Miao, Zhuang

    2016-01-01

    Highlights: • The absorption performance for iodide vapour was studied under different conditions. • A mathematical model was developed to describe the iodide absorption process. • The venturi scrubber can ensure absorption efficiiency and reduce pressure loss. - Abstract: The self-priming venturi scrubber is the key component of filtered containment venting systems for the removal of radioactive products during severe accidents in nuclear power plants. This paper is focused on the absorption performance of iodide vapour in the venturi scrubber, based on experiment and mathematical calculation. The results indicate that the absorption efficiency is closely related to solution flow rate, gas flow rate and temperature, but is not sensitive to iodide inlet concentration. When solution flow rate is low, the absorption efficiency increases rapidly with increasing the solution flow rate, and when the solution is excessive, the absorption efficiency remains around 99% stably; the influence of gas flow rate on absorption efficiency is mainly reflected in the variation of gas and liquid contacting time; when the solution flow rate is low, the increase of gas flow rate will led to an obvious decrease in absorption efficiency; temperature is not important when gas flow rate in constant but becomes effective for improving the absorption efficiency when gas velocity is constant. The proposed mathematical model can predict the iodide absorption process well in the range of experimental conditions. Especially, in the condition of lower gas flow rate and higher solution flow rate, the prediction accuracy is more satisfactory; however the accuracy of prediction will decrease at higher gas flow rates and lower solution flow rates because of neglecting the transverse exchange between gas and liquid phase.

  1. Performance analysis of the single-stage absorption heat transformer using a new working pair composed of ionic liquid and water

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Hu Dapeng

    2012-01-01

    The performance simulation of a single-stage absorption heat transformer using a new working pair composed of ionic liquids, 1-ethyl-3-methylimidazolium dimethylphosphate, and water (H 2 O + [EMIM][DMP]), was performed based on the thermodynamic properties of the new working pair and on the mass and energy balance for each component of the system. In order to evaluate the new working pair, the simulation results were compared with those of aqueous solution of lithium bromide (H 2 O + LiBr), Trifluoroethanol (TFE) + tetraethylenglycol dimethylether (E181). The results indicate that when generation, evaporation, condensing and absorption temperatures are 90 °C, 90 °C, 35 °C and 130 °C, the coefficients of performance of the single-stage absorption heat transformer using H 2 O + LiBr, H 2 O + [EMIM][DMP] and TFE + E181 as working pairs will reach 0.494, 0.481 and 0.458 respectively. And the corresponding exergy efficiency will reach 0.64, 0.62 and 0.59, respectively. Meanwhile the available heat outputs for per unit mass of refrigerant are 2466 kJ/kg, 2344 kJ/kg and 311 kJ/kg, respectively. The above excellent cycle performance together with the advantages of negligible vapor pressure, no crystallization and more weak corrosion tendency to iron-steel materials may make the new working pair better suited for the industrial absorption heat transformer. - Highlights: ► The cycle performance of the single-stage absorption heat transformer was simulated. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate was used as new working pair. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate are entirely miscible. ► The COP and exergy efficiency for this new working pairs were 0.481 and 0.62. ► The new working pairs has potential application to absorption heat transformer.

  2. Modified ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction followed by atomic absorption spectrometry for trace determination of zinc in water and food samples

    International Nuclear Information System (INIS)

    Zeeb, M.; Sadeghi, M.

    2011-01-01

    We report on a new method for the microextraction and determination of zinc (II). The ion is accumulated via ionic-liquid cold-induced aggregation dispersive liquid-liquid microextraction (IL-CIA-DLLME) followed by flame atomic absorption spectrometry (FAAS). The ionic liquid (IL) 1-hexyl-3-methylimidazolium hexafluorophosphate is dispersed into a heated sample solution containing sodium hexafluorophosphate as a common ion source. The solution is then placed in an ice-water bath upon which a cloudy solution forms due to the decrease of the solubility of the IL. Zinc is complexed with 8-hydroxyquinoline and extracted into the IL. The enriched phase is dissolved in a diluting agent and introduced to the FAAS. The method is not influenced by variations in the ionic strength of the sample solution. Factors affecting the performance were evaluated and optimized. At optimum conditions, the limit of detection is 0.18 μg L -1 , and the relative standard deviation is 3.0% (at n=5). The method was validated by recovery experiments and by analyzing a certified reference material and successfully applied to the determination of Zn (II) in water and food samples. (author)

  3. A novel absorption refrigeration cycle for heat sources with large temperature change

    International Nuclear Information System (INIS)

    Yan, Xiaona; Chen, Guangming; Hong, Daliang; Lin, Shunrong; Tang, Liming

    2013-01-01

    To increase the use efficiency of available thermal energy in the waste gas/water, a novel high-efficient absorption refrigeration cycle regarded as an improved single-effect/double-lift configuration is proposed. The improved cycle using an evaporator/absorber (E/A) promotes the coefficient of performance and reduces the irreversible loss. Water–lithium bromide is used as the working pair and a simulation study under the steady working conditions is conducted. The results show that the temperature of waste gas discharged is about 20 °C lower than that of the conventional single-effect cycle and the novel cycle we proposed can achieve more cooling capacity per unit mass of waste gas/water at the simulated working conditions. -- Graphical abstract: Pressure – temperature diagram for water – lithium bromide. Highlights: ► A novel waste heat-driven absorption refrigeration cycle is presented. ► The novel cycle can reject heat at much lower temperature. ► The available temperature range of heat source of the proposed cycle is wider. ► Multiple heat sources with different temperatures can be used in the novel cycle

  4. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Absorption Spectra Of Rbcl:Yb Rbbr:Yb And Rbi:Yb Crystals ...

    African Journals Online (AJOL)

    Single crystals of rubidium chloride, bromide and iodide were doped with substitutional divalent ytterbium, Yb ions, by heating them in ytterbium atmosphere. The absorption spectra of the Yb doped crystals were measured at room and liquid nitrogen temperatures. The spectra were found to consist of intense broad ...

  6. UV absorption cross-sections of selected sulfur-containing compounds at temperatures up to 500°C

    DEFF Research Database (Denmark)

    Grosch, Helge; Fateev, Alexander; Clausen, Sønnik

    2015-01-01

    The temperature dependence of the ultraviolet absorption cross-sections of three different sulfur containing compounds, hydrogen sulfide (H2S), carbon disulfide (CS2) and carbonyl sulfide (OCS), are presented between 200nm and 360nm at a resolution of 0.018nm. The absorption cross-sections for each...... compound are initially compared with those available in the literature, followed by the discussion of the measurements and their spectral features at three temperatures up to 500°C/773K. Uncertainties in the measured absorption cross-sections are also addressed....

  7. The absorption of thermal radiation by water films

    International Nuclear Information System (INIS)

    Pearson, K.G.; Elliott, D.

    1977-04-01

    Except at the shortest wavelengths (i.e. <2μm) liquid water is relatively opaque to thermal radiation. It is also a poor reflector, reflecting back only about 2% of normal incident radiation. It is shown that when radiation falls on a plane water surface from a parallel heated surface about 93.5% of the incident radiation enters the surface, the remaining 6.5% being reflected back to the source. It is also shown that, for source temperatures up to the maximum of interest in reactor safety studies, a large fraction of the thermal radiation which enters the water is absorbed on passing through a distance approaching 0.5 mm. Since liquid water films of such thickness can be expected to exist on the pressure tubes of an SGHWR following a loss of coolant accident it follows that, irrespective of the condition of the pressure tube wall, the absorptivity of the pressure tubes will in effect be about 0.9. Data are presented for experiments performed to determine the absorptivity of water films on a polished surface whose dry absorptivity was measured to be 0.18. The presence of the water film, of estimated thickness 0.3 mm, increased the absorptivity of the surface to a value close to unity. (author)

  8. IMPROVED SYNTHESIS OF ROOM TEMPERATURE IONIC LIQUIDS

    Science.gov (United States)

    Room temperature ionic liquids (RTILs), molten salts comprised of N-alkylimidazolium cations and various anions, have received significant attention due to their commercial potential in a variety of chemical applications especially as substitutes for conventional volatile organic...

  9. A furnace and temperature controller for optical absorption studies with a spectrophotometer

    International Nuclear Information System (INIS)

    Mariani Rogat, F.

    1975-01-01

    The design and main features of a furnace with a temperature controller and programmer are shown. This system allows to measure the optical absorption spectrum of a sample from room temperature to 400 deg C, in a double beam spectrophotometer Perkin Elmer 350. The sample temperature can be linearly increased at different heating rates between 4 and 38 deg C/min. The temperature ramp can be stopped at any desired point and the sample temperature shall be stabilized in less than one minute. This temperature shall be kept constant within 0.5 deg C for hours. The sample is heated in vacuum. (author)

  10. Temperature-Frequency Converter Using a Liquid Crystal Cell as a Sensing Element

    Directory of Open Access Journals (Sweden)

    José Isidro Santos

    2012-03-01

    Full Text Available A new temperature-frequency converter based on the variation of the dielectric permittivity of the Liquid Crystal (LC material with temperature has been demonstrated. Unlike other temperature sensors based on liquid crystal processing optical signals for determining the temperature, this work presents a system that is able to sense temperature by using only electrical signals. The variation of the dielectric permittivity with temperature is used to modify the capacitance of a plain capacitor using a LC material as non-ideal dielectric. An electric oscillator with an output frequency depending on variable capacitance made of a twisted-nematic (TN liquid crystal (LC cell has been built. The output frequency is related to the temperature of LC cell through the equations associated to the oscillator circuit. The experimental results show excellent temperature sensitivity, with a variation of 0.40% of the initial frequency per degree Celsius in the temperature range from −6 °C to 110 °C.

  11. Coolant and ambient temperature control for chillerless liquid cooled data centers

    Science.gov (United States)

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Simons, Robert E.

    2016-02-02

    Cooling control methods include measuring a temperature of air provided to a plurality of nodes by an air-to-liquid heat exchanger, measuring a temperature of at least one component of the plurality of nodes and finding a maximum component temperature across all such nodes, comparing the maximum component temperature to a first and second component threshold and comparing the air temperature to a first and second air threshold, and controlling a proportion of coolant flow and a coolant flow rate to the air-to-liquid heat exchanger and the plurality of nodes based on the comparisons.

  12. Confinement effect of laser ablation plume in liquids probed by self-absorption of C2 Swan band emission

    International Nuclear Information System (INIS)

    Sakka, Tetsuo; Saito, Kotaro; Ogata, Yukio H.

    2005-01-01

    The (0,0) Swan band of the C 2 molecules in a laser ablation plume produced on the surface of graphite target submerged in water was used as a probe to estimate the density of C 2 molecules in the plume. Observed emission spectra were reproduced excellently by introducing a self-absorption parameter to the theoretical spectral profile expected by a rotational population distribution at a certain temperature. The optical density of the ablation plume as a function of time was determined as a best-fit parameter by the quantitative fitting of the whole spectral profile. The results show high optical densities for the laser ablation plume in water compared with that in air. It is related to the plume confinement or the expansion, which are the important phenomena influencing the characteristics of laser ablation plumes in liquids

  13. Ionic liquids and ionic liquid acids with high temperature stability for fuel cell and other high temperature applications, method of making and cell employing same

    Science.gov (United States)

    Angell, C Austen [Mesa, AZ; Xu, Wu [Broadview Heights, OH; Belieres, Jean-Philippe [Chandler, AZ; Yoshizawa, Masahiro [Tokyo, JP

    2011-01-11

    Disclosed are developments in high temperature fuel cells including ionic liquids with high temperature stability and the storage of inorganic acids as di-anion salts of low volatility. The formation of ionically conducting liquids of this type having conductivities of unprecedented magnitude for non-aqueous systems is described. The stability of the di-anion configuration is shown to play a role in the high performance of the non-corrosive proton-transfer ionic liquids as high temperature fuel cell electrolytes. Performance of simple H.sub.2(g) electrolyte/O.sub.2(g) fuel cells with the new electrolytes is described. Superior performance both at ambient temperature and temperatures up to and above 200.degree. C. are achieved. Both neutral proton transfer salts and the acid salts with HSO.sup.-.sub.4 anions, give good results, the bisulphate case being particularly good at low temperatures and very high temperatures. The performance of all electrolytes is improved by the addition of a small amount of involatile base of pK.sub.a value intermediate between those of the acid and base that make the bulk electrolyte. The preferred case is the imidazole-doped ethylammonium hydrogensulfate which yields behavior superior in all respects to that of the industry standard phosphoric acid electrolyte.

  14. Mathematical Model-Based Temperature Preparation of Liquid-Propellant Components Cooled by Liquid Nitrogen in the Heat Exchanger with a Coolant

    Directory of Open Access Journals (Sweden)

    S. K. Pavlov

    2014-01-01

    Full Text Available Before fuelling the tanks of missiles, boosters, and spacecraft with liquid-propellant components (LPC their temperature preparation is needed. The missile-system ground equipment performs this operation during prelaunch processing of space-purpose missiles (SPM. Usually, the fuel cooling is necessary to increase its density and provide heat compensation during prelaunch operation of SPM. The fuel temperature control systems (FTCS using different principles of operation and types of coolants are applied for fuel cooling.To determine parameters of LPC cooling process through the fuel heat exchange in the heat exchanger with coolant, which is cooled by liquid nitrogen upon contact heat exchange in the coolant reservoir, a mathematical model of this process and a design technique are necessary. Both allow us to determine design parameters of the cooling system and the required liquid nitrogen reserve to cool LPC to the appropriate temperature.The article presents an overview of foreign and domestic publications on cooling processes research and implementation using cryogenic products such as liquid nitrogen. The article draws a conclusion that it is necessary to determine the parameters of LPC cooling process through the fuel heat exchange in the heat exchanger with coolant, which is liquid nitrogen-cooled upon contact heat exchange in the coolant reservoir allowing to define rational propellant cooling conditions to the specified temperature.The mathematical model describes the set task on the assumption that a heat exchange between the LPC and the coolant in the heat exchanger and with the environment through the walls of tanks and pipelines of circulation loops is quasi-stationary.The obtained curves allow us to calculate temperature changes of LPC and coolant, cooling time and liquid nitrogen consumption, depending on the process parameters such as a flow rate of liquid nitrogen, initial coolant temperature, pump characteristics, thermal

  15. Temperature dependent absorption spectra of Br(-), Br2(•-), and Br3(-) in aqueous solutions.

    Science.gov (United States)

    Lin, Mingzhang; Archirel, Pierre; Van-Oanh, Nguyen Thi; Muroya, Yusa; Fu, Haiying; Yan, Yu; Nagaishi, Ryuji; Kumagai, Yuta; Katsumura, Yosuke; Mostafavi, Mehran

    2011-05-05

    The absorption spectra of Br(2)(•-) and Br(3)(-) in aqueous solutions are investigated by pulse radiolysis techniques from room temperature to 380 and 350 °C, respectively. Br(2)(•-) can be observed even in supercritical conditions, showing that this species could be used as a probe in pulse radiolysis at high temperature and even under supercritical conditions. The weak temperature effect on the absorption spectra of Br(2)(•-) and Br(3)(-) is because, in these two systems, the transition occurs between two valence states; for example, for Br(2)(-) we have (2)Σ(u) → (2)Σ(g) transition. These valence transitions involve no diffuse final state. However, the absorption band of Br(-) undergoes an important red shift to longer wavelengths. We performed classical dynamics of hydrated Br(-) system at 20 and 300 °C under pressure of 25 MPa. The radial distribution functions (rdf's) show that the strong temperature increase (from 20 to 300 °C) does not change the radius of the solvent first shell. On the other hand, it shifts dramatically (by 1 Å) the second maximum of the Br-O rdf and introduces much disorder. This shows that the first water shell is strongly bound to the anion whatever the temperature. The first two water shells form a cavity of a roughly spherical shape around the anion. By TDDFT method, we calculated the absorption spectra of hydrated Br(-) at two temperatures and we compared the results with the experimental data.

  16. Multiwalled carbon nanotubes sensor for organic liquid detection at room temperature

    Science.gov (United States)

    Chaudhary, Deepti; Khare, Neeraj; Vankar, V. D.

    2016-04-01

    We have explored the possibility of using multiwalled carbon nanotubes (MWCNTs) as room temperature chemical sensor for the detection of organic liquids such as ethanol, propanol, methanol and toluene. MWCNTs were synthesized by thermal chemical vapor deposition (TCVD) technique. The interdigitated electrodes were fabricated by conventional photolithography technique. The sensor was fabricated by drop depositing MWCNT suspension onto the interdigitated electrodes. The sensing properties of MWCNTs sensor was studied for organic liquids detection. The resistance of sensor was found to increase upon exposure to these liquids. Sensor shows good reversibility and fast response at room temperature. Charge transfer between the organic liquid and sensing element is the dominant sensing mechanism.

  17. Development of the krypton absorption in liquid carbon dioxide (KALC) process for HTGR off-gas reprocessing

    International Nuclear Information System (INIS)

    Glass, R.W.; Beaujean, H.W.R.; Cochran, H.D. Jr.; Haas, P.A.; Levins, D.M.; Woods, W.M.

    1975-01-01

    Reprocessing of High-Temperature Gas-Cooled Reactor (HTGR) fuel involves burning of the graphite-matrix elements to release the fuel for recovery purposes. The resulting off-gas is primarily CO 2 with residual amounts of N 2 , O 2 , and CO, together with fission products. Trace quantities of krypton-85 must be recovered in a concentrated form from the gas stream, but processes commonly employed for rare gas removal and concentration are not suitable for use with off-gas from graphite burning. The KALC (Krypton Absorption in Liquid CO 2 ) process employs liquid CO 2 as a volatile solvent for the krypton and is, therefore, uniquely suited to the task. Engineering development of the KALC process is currently under way at the Oak Ridge National Laboratory (ORNL) and the Oak Ridge Gaseous Diffusion Plant (ORGDP). The ORNL system is designed for close study of the individual separation operations involved in the KALC process, while the ORGDP system provides a complete pilot facility for demonstrating combined operations on a somewhat larger scale. Packed column performance and process control procedures have been of prime importance in the initial studies. Computer programs have been prepared to analyze and model operational performance of the KALC studies, and special sampling and in-line monitoring systems have been developed for use in the experimental facilities. (U.S.)

  18. Stability analysis of high temperature superconducting coil in liquid hydrogen

    International Nuclear Information System (INIS)

    Nakayama, T.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2007-01-01

    Recently, it is expected that hydrogen plays an important role in energy source including electric power in near future. Liquid hydrogen has high potential for cooling down superconducting coil wound with high temperature superconductors (HTS), such as BSCCO, YBCO. In this paper, we study stabilities of the coils wound with BSCCO tapes, which are immersed in the liquid hydrogen, and compare stability results with those cooled by liquid helium. We treat a minimum propagation zone (MPZ) theory to evaluate the coil stability considering boiling heat flux of the liquid hydrogen, and specific heat, heat conduction and resistivity of HTS materials as a function of temperature. It is found that the coil cooled by the liquid hydrogen has higher stability margin than that cooled by the liquid helium. We compare the stability margins of both coils wound with Bi-2223/Ag tape and Bi-2212/Ag tape in liquid hydrogen. As a result, it is found that the stability of Bi-2212 coil is equivalent to that of Bi-2223 coil in low and high magnetic field, while the maximum current of Bi-2212 coil exceeds a little bit that of Bi-2223 coil in both magnetic fields

  19. [Detecting Thallium in Water Samples using Dispersive Liquid Phase Microextraction-Graphite Furnace Atomic Absorption Spectroscopy].

    Science.gov (United States)

    Zhu, Jing; Li, Yan; Zheng, Bo; Tang, Wei; Chen, Xiao; Zou, Xiao-li

    2015-11-01

    To develope a method of solvent demulsification dispersive liquid phase microextraction (SD-DLPME) based on ion association reaction coupled with graphite furnace atomic absorption spectroscopy (GFAAS) for detecting thallium in water samples. Methods Thallium ion in water samples was oxidized to Tl(III) with bromine water, which reacted with Cl- to form TlCl4-. The ionic associated compound with trioctylamine was obtained and extracted. DLPME was completed with ethanol as dispersive solvent. The separation of aqueous and organic phase was achieved by injecting into demulsification solvent without centrifugation. The extractant was collected and injected into GFAAS for analysis. With palladium colloid as matrix modifier, a two step drying and ashing temperature programming process was applied for high precision and sensitivity. The linear range was 0.05-2.0 microg/L, with a detection limit of 0.011 microg/L. The relative standard derivation (RSD) for detecting Tl in spiked water sample was 9.9%. The spiked recoveries of water samples ranged from 94.0% to 103.0%. The method is simple, sensitive and suitable for batch analysis of Tl in water samples.

  20. Notre Dame Geothermal Ionic Liquids Research: Ionic Liquids for Utilization of Geothermal Energy

    Energy Technology Data Exchange (ETDEWEB)

    Brennecke, Joan F. [Univ. of Notre Dame, IN (United States)

    2017-03-07

    The goal of this project was to develop ionic liquids for two geothermal energy related applications. The first goal was to design ionic liquids as high temperature heat transfer fluids. We identified appropriate compounds based on both experiments and molecular simulations. We synthesized the new ILs, and measured their thermal stability, measured storage density, viscosity, and thermal conductivity. We found that the most promising compounds for this application are aminopyridinium bis(trifluoromethylsulfonyl)imide based ILs. We also performed some measurements of thermal stability of IL mixtures and used molecular simulations to better understand the thermal conductivity of nanofluids (i.e., mixtures of ILs and nanoparticles). We found that the mixtures do not follow ideal mixture theories and that the addition of nanoparticles to ILs may well have a beneficial influence on the thermal and transport properties of IL-based heat transfer fluids. The second goal was to use ionic liquids in geothermally driven absorption refrigeration systems. We performed copious thermodynamic measurements and modeling of ionic liquid/water systems, including modeling of the absorption refrigeration systems and the resulting coefficients of performance. We explored some IL/organic solvent mixtures as candidates for this application, both with experimentation and molecular simulations. We found that the COPs of all of the IL/water systems were higher than the conventional system – LiBr/H2O. Thus, IL/water systems appear very attractive for absorption refrigeration applications.

  1. Temperature dependence of the two photon absorption in indium arsenide

    International Nuclear Information System (INIS)

    Berryman, K.W.; Rella, C.W.

    1995-01-01

    Nonlinear optical processes in semiconductors have long been a source of interesting physics. Two photon absorption (TPA) is one such process, in which two photons provide the energy for the creation of an electron-hole pair. Researchers at other FEL centers have studied room temperature TPA in InSb, InAs, and HgCdTe. Working at the Stanford Picosecond FEL Center, we have extended and refined this work by measuring the temperature dependence of the TPA coefficient in InAs over the range from 80 to 350 K at four wavelengths: 4.5, 5.06, 6.01, and 6.3 microns. The measurements validate the functional dependence of recent band structure calculations with enough precision to discriminate parabolic from non-parabolic models, and to begin to observe smaller effects, such as contributions due to the split-off band. These experiments therefore serve as a strong independent test of the Kane band theory, as well as providing a starting point for detailed observations of other nonlinear absorption mechanisms

  2. Temperature and isotope effects on the shape of the optical absorption spectrum of solvated electrons in water

    International Nuclear Information System (INIS)

    Jou, F.Y.; Freeman, G.R.

    1979-01-01

    The optical absorption spectra of solvated electrons in H 2 O and D 2 O have been measured at 274, 298, 340, and 380 K. All the spectra were fitted very well with the Gaussian and Lorentzian shape functions at the low- and high-energy sides of the absorption maximum, respectively, excluding the high-energy tail. The spectrum does not shift uniformly with temperature. The temperature coefficient of absorption decreases rapidly with increasing energy on the low-energy side of the absorption maximum, while it changes only slightly on the high-energy side. When the temperature increases the Lorentzian width remains constant, the Gaussian width varies proportionally to T/sup 1/2/, and the spectrum becomes more symmetrical. On going from H 2 O to D 2 O we found that the spectrum at a given A/A/sub max/ shows a shift of +0.05 eV in the low-energy wing. The shift decreases with increasing energy, reaching 0.03 eV at the absorption maximum. On the high-energy side of the band the shift becomes negative at hν > 2.2 eV. The shift on the low-energy side seems to be related to the difference of the zero-point energies of the inter- and intramolecular vibrations. The wavelength dependence of the temperature and isotope effects is consistent with the model that different types of excitation occur on the low- and high-energy sides of the absorption band. The temperature and isotopic dependence of the low-energy side are consistent with its width being due to phonon interactions

  3. Temperature and pressure dependent osmotic pressure in liquid sodium-cesium alloys

    International Nuclear Information System (INIS)

    Rashid, R.I.M.A.

    1987-01-01

    The evaluation of the osmotic pressure in terms of the concentration fluctuations of mixtures and the equations of state of the pure liquids is considered. The temperature and pressure dependent experimentally measured concentration-concentration correlations in the long wavelength limit of liquid sodium-cesium alloys are used to demonstrate the appreciable dependence of the temperature and pressure on the osmotic pressure as a function of concentration. Introducing interchange energies as functions of temperature and pressure, our analysis is consistent with the Flory model. Thus, a formalism for evaluating the state dependent osmotic pressure is developed and our numerical work is considered to be an extension of the calculations of Rashid and March in the sense that a temperature and pressure dependent interchange energy parameter that more closely parameterizes the state dependent concentration fluctuations in the liquid alloys, is used. (author)

  4. Edge-plasma analysis for liquid-wall MFE concepts

    International Nuclear Information System (INIS)

    Moir, R.W.; Rensink, M.E.; Rognlien, T.D.

    2001-01-01

    A thick flowing layer of liquid (e.g., flibe - a molten salt, or Sn 80 Li 20 - a liquid metal) protects the structural walls of the magnetic fusion configuration so that they can last the life of the plant even with intense 14 MeV neutron bombardment from the D-T fusion reaction. The surface temperature of the liquid rises as it passes from the inlet nozzles to the exit nozzles due to absorption of line and bremsstrahlung radiation, and neutrons. The surface temperature can be reduced by enhanced turbulent convection of hot surface liquid into the cooler interior. This surface temperature is affected by the temperature of liquid from a heat transport and energy recovery system. The evaporative flux from the wall driven by the surface temperature must also result in an acceptable impurity level in the core plasma. The shielding of the core by the edge plasma is modeled with a 2D-transport code for the DT and impurity ions; these impurity ions are either swept out to the divertor, or diffuse to the hot plasma core. An auxiliary plasma between the edge plasma and the liquid wall may further attenuate evaporating flux of atoms and molecules by ionization near the wall. (author)

  5. Influence of the laser-diode temperature on crystal absorption and ...

    Indian Academy of Sciences (India)

    Abstract. In this work, we studied the influence of heat loaded into the laser crystal in an end- pumped solid-state Nd:YVO4 high power laser. We have shown experimentally that the optimum value of the laser-diode temperature for the maximum pump power absorption by the Nd:YVO4 crystal and the maximum Nd:YVO4 ...

  6. Excitation of cavitation bubbles in low-temperature liquid nitrogen

    Science.gov (United States)

    Sasaki, Koichi; Harada, Shingo

    2017-06-01

    We excited a cavitation bubble by irradiating a Nd:YAG laser pulse onto a titanium target that was installed in liquid nitrogen at a temperature below the boiling point. To our knowledge, this is the first experiment in which a cavitation bubble has been successfully excited in liquid nitrogen. We compared the cavitation bubble in liquid nitrogen with that in water on the basis of an equation reported by Florschuetz and Chao [J. Heat Transfer 87, 209 (1965)].

  7. Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

    Science.gov (United States)

    Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick

    2000-01-01

    We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

  8. Influence of temperature on water and aqueous glucose absorption spectra in the near- and mid-infrared regions at physiologically relevant temperatures

    DEFF Research Database (Denmark)

    Jensen, P.S.; Bak, J.; Andersson-Engels, S.

    2003-01-01

    transmission cell controlled within 0.02 degreesC. Pathlengths of 50 mum and 0.4 mm were used in the mid- and near-infrared spectral region, respectively. Difference spectra were used to determine the effect of temperature on the water spectra quantitatively. These spectra were obtained by subtracting the 37...... degreesC water spectrum from the spectra measured at other temperatures. The difference spectra reveal that the effect of temperature is highest in the vicinity of the strong absorption bands, with a number of isosbestic points with no temperature dependence and relatively flat plateaus in between......Near- and mid-infrared absorption spectra of pure water and aqueous 1.0 g/dL glucose solutions in the wavenumber range 8000-950 cm(-1) were measured in the temperature range 30-42 C in steps of 2 degreesC. Measurements were carried out with an FT-IR spectrometer and a variable pathlength...

  9. Determination of cobalt in human biological liquids from electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dragan, Felicia [University of Oradea, Faculty of Medicine and Pharmacy, 29 N Jiga, 410028 Oradea (Romania); HIncu, Lucian [University of Medicine and Pharmacy ' Carol Davila' , Faculty of Pharmacy, 6 Traian Vuia, 020956 Bucuresti (Romania); Bratu, Ioan, E-mail: fdragan@uoradea.r [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania)

    2009-08-01

    Problems and possibilities of the determination of Co in serum and urine samples by electrothermal atomic absorption spectrometry (ETAAS) are described. Optimal instrumental parameters as well as a suitable atomizer, calibration procedure and hydrogen peroxide as modifier are proposed for direct ETAAS measurement of Co in serum and urine. The detection limit achieved was 0.1 {mu}g L{sup -1} for both matrices and relative standard deviations varied in the range 5-20% depending on the Co concentration in the sample. The validity of the method was verified by the analyses of standard reference materials. For serum samples with Co content lower than the detection limit, a separation and preconcentration procedure based on liquid/liquid extraction is suggested prior to determination of Co in the organic phase by ETAAS. This procedure permits determination of 0.02 {mu}g L{sup -1} Co in serum samples with a relative standard deviation of 10-18%.

  10. A High Temperature Liquid Plasma Model of the Sun

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2007-01-01

    Full Text Available In this work, a liquid model of the Sun is presented wherein the entire solar mass is viewed as a high density/high energy plasma. This model challenges our current understanding of the densities associated with the internal layers of the Sun, advocating a relatively constant density, almost independent of radial position. The incompressible nature of liquids is advanced to prevent solar collapse from gravitational forces. The liquid plasma model of the Sun is a non-equilibrium approach, where nuclear reactions occur throughout the solar mass. The primary means of addressing internal heat transfer are convection and conduction. As a result of the convective processes on the solar surface, the liquid model brings into question the established temperature of the solar photosphere by highlighting a violation of Kirchhoff’s law of thermal emission. Along these lines, the model also emphasizes that radiative emission is a surface phenomenon. Evidence that the Sun is a high density/high energy plasma is based on our knowledge of Planckian thermal emission and condensed matter, including the existence of pressure ionization and liquid metallic hydrogen at high temperatures and pressures. Prior to introducing the liquid plasma model, the historic and scientific justifications for the gaseous model of the Sun are reviewed and the gaseous equations of state are also discussed.

  11. Temperature dependent structural and vibrational properties of liquid indium

    Science.gov (United States)

    Patel, A. B.; Bhatt, N. K.

    2018-05-01

    The influence of the temperature effect on both the structure factor and the phonon dispersion relation of liquid indium have been investigated by means of pseudopotential theory. The Percus-Yevick Hard Sphere reference system is applied to describe the structural calculation. The effective electron-ion interaction is explained by using modified empty core potential due to Hasegawa et al. along with a local field correction function due to Ichimaru-Utsumi (IU). The temperature dependence of pair potential needed at higher temperatures was achieved by multiplying the damping factor exp(- π/kBT2k F r ) in the pair potential. Very close agreement of static structure factor, particularly, at elevated temperatures confirms the validity of the local potential. A positive dispersion is found in low-q region and the correct trend of phonon dispersion branches like the experimental; shows all broad features of collective excitations in liquid metals.

  12. High-temperature measurements of methane and acetylene using quantum cascade laser absorption near 8μm

    KAUST Repository

    Sajid, M.B.

    2015-04-01

    The mid-infrared wavelength region near 8 mu m contains absorption bands of several molecules such as water vapor, hydrogen peroxide, nitrous oxide, methane and acetylene. A new laser absorption sensor based on the v(4) band of methane and the v(4)+v(5) band of acetylene is reported for interference-free, time-resolved measurements under combustion-relevant conditions. A detailed line-selection procedure was used to identify optimum transitions. Methane and acetylene were measured at the line centers of Q12 (1303.5 cm(-1)) and P23 (1275.5 cm(-1)) transitions, respectively. High-temperature absorption cross sections of methane and acetylene were measured at peaks (on-line) and valleys (off-line) of the selected absorption transitions. The differential absorption strategy was employed to eliminate interference absorption from large hydrocarbons. Experiments were performed behind reflected shock waves over a temperature range of 1200-2200 K, between pressures of 1-4 atm. The diagnostics were then applied to measure the respective species time-history profiles during the shock-heated pyrolysis of n-pentane. (C) 2015 Elsevier Ltd. All rights reserved.

  13. Selection of the optimal combination of water vapor absorption lines for detection of temperature in combustion zones of mixing supersonic gas flows by diode laser absorption spectrometry

    International Nuclear Information System (INIS)

    Mironenko, V.R.; Kuritsyn, Yu.A.; Bolshov, M.A.; Liger, V.V.

    2017-01-01

    Determination of a gas medium temperature by diode laser absorption spectrometry (DLAS) is based on the measurement of integral intensities of the absorption lines of a test molecule (generally water vapor molecule). In case of local thermodynamic equilibrium temperature is inferred from the ratio of the integral intensities of two lines with different low energy levels. For the total gas pressure above 1 atm the absorption lines are broadened and one cannot find isolated well resolved water vapor absorption lines within relatively narrow spectral interval of fast diode laser (DL) tuning range (about 3 cm"−"1). For diagnostics of a gas object in the case of high temperature and pressure DLAS technique can be realized with two diode lasers working in different spectral regions with strong absorption lines. In such situation the criteria of the optimal line selection differs significantly from the case of narrow lines. These criteria are discussed in our work. The software for selection the optimal spectral regions using the HITRAN-2012 and HITEMP data bases is developed. The program selects spectral regions of DL tuning, minimizing the error of temperature determination δT/T, basing on the attainable experimental error of line intensity measurement δS. Two combinations of optimal spectral regions were selected – (1.392 & 1.343 μm) and (1.392 & 1.339 μm). Different algorithms of experimental data processing are discussed.

  14. Development and Validation of a Sensitive Method for Trace Nickel Determination by Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Dispersive Liquid-Liquid Microextraction.

    Science.gov (United States)

    Yolcu, Şükran Melda; Fırat, Merve; Chormey, Dotse Selali; Büyükpınar, Çağdaş; Turak, Fatma; Bakırdere, Sezgin

    2018-05-01

    In this study, dispersive liquid-liquid microextraction was systematically optimized for the preconcentration of nickel after forming a complex with diphenylcarbazone. The measurement output of the flame atomic absorption spectrometer was further enhanced by fitting a custom-cut slotted quartz tube to the flame burner head. The extraction method increased the amount of nickel reaching the flame and the slotted quartz tube increased the residence time of nickel atoms in the flame to record higher absorbance. Two methods combined to give about 90 fold enhancement in sensitivity over the conventional flame atomic absorption spectrometry. The optimized method was applicable over a wide linear concentration range, and it gave a detection limit of 2.1 µg L -1 . Low relative standard deviations at the lowest concentration in the linear calibration plot indicated high precision for both extraction process and instrumental measurements. A coal fly ash standard reference material (SRM 1633c) was used to determine the accuracy of the method, and experimented results were compatible with the certified value. Spiked recovery tests were also used to validate the applicability of the method.

  15. Recovery time of high temperature superconducting tapes exposed in liquid nitrogen

    International Nuclear Information System (INIS)

    Sheng, Jie; Zeng, Weina; Yao, Zhihao; Zhao, Anfeng; Hu, Daoyu; Hong, Zhiyong

    2016-01-01

    Highlights: • A novel method based on a sequence of AC pulses is presented. • Liquid nitrogen temperature is used as criterion to judge whether the sample has recovered. • Recovery time of some tape doesn't increase with the amplitude of fault current. • This phenomenon is caused by boiling heat transfer process of liquid nitrogen. • This phenomenon can be used in optimizing both the limiting rate and reclosing system. - Abstract: The recovery time is a crucial parameter to high temperature superconducting tapes, especially in power applications. The cooperation between the reclosing device and the superconducting facilities mostly relies on the recovery time of the superconducting tapes. In this paper, a novel method is presented to measure the recovery time of several different superconducting samples. In this method criterion used to judge whether the sample has recovered is the liquid nitrogen temperature, instead of the critical temperature. An interesting phenomenon is observed during the testing of superconducting samples exposed in the liquid nitrogen. Theoretical explanations of this phenomenon are presented from the aspect of heat transfer. Optimization strategy of recovery characteristics based on this phenomenon is also briefly discussed.

  16. Iron species determination by task-specific ionic liquid-based in situ solvent formation dispersive liquid-liquid microextraction combined with flame atomic absorption spectrometry.

    Science.gov (United States)

    Sadeghi, Susan; Ashoori, Vahid

    2017-10-01

    The task-specific ionic liquid (TSIL) of 1-ethyl-3-methylimidazolium bromide functionalized with 8-hydroxyquinoline was used as a chelating agent and extracting solvent for dispersive liquid-liquid microextraction and subsequent determination of Fe(III) by flame atomic absorption spectrometry. The in situ solvent formation of TSIL using KPF 6 provided the desired water-immiscible ionic liquid. The total Fe concentration could be determined after pre-oxidation of Fe(II) to Fe(III). Various factors affecting the proposed extraction procedure were optimized. The proposed analytical conditions were: sample pH 5, TSIL amount 0.3% (w/v), KPF 6 amount 0.15% (w/v), anti-sticking 0.1% (w/v) and salt concentration 5% (w/v). Under optimal conditions, the linear dynamic ranges for Fe(III) and total Fe were 20-80 and 20-110 ng mL -1 , respectively, with a detection limit of 6.9 ng mL -1 for Fe(III) and relative standard deviation of 2.2%. The proposed method was successfully applied to the determination of trace Fe(III) in water (underground, tap, refined water and artificial sea water) and beverage (apple, tomato, and tea) samples. The developed method offers advantages such as simplicity, ease of operation, and extraction of Fe(III) from aqueous solutions without the use of organic solvent. It was successfully applied for iron speciation in different real samples. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. Platform development of x-ray absorption-based temperature measurements above 100-eV on the OMEGA laser

    Science.gov (United States)

    Workman, Jonathan; Keiter, P.; Tierney, T.; Tierney, H.; Belle, K.; Magelssen, G.; Peterson, R.; Fryer, C.; Comley, A.; Taylor, M.

    2007-11-01

    Experiments were performed on the OMEGA laser system at the University of Rochester to measure radiation temperature in hohlraum-heated foams. Using x-ray absorption spectroscopy in the 3-6-keV x-ray range allows temperature determination in the range of 50-200-eV. Uranium, bismuth and gold M-shell x-ray emission were used as broadband backlighters. Backlighter absorption through heated chlorinated foam and scandium tracers were used to determine temperatures. The development of this technique in the temperature range of 100-200-eV will be used for platform development of future NIF experiments. We will present time-integrated and time-resolved measurements of x-ray emission from the backlighter materials as well as absorption measurements trough the heated tracer materials. We will also present future directions in the development of this platform.

  18. A simulation study on the abatement of CO2 emissions by de-absorption with monoethanolamine.

    Science.gov (United States)

    Greer, T; Bedelbayev, A; Igreja, J M; Gomes, J F; Lie, B

    2010-01-01

    Because of the adverse effect of CO2 from fossil fuel combustion on the earth's ecosystems, the most cost-effective method for CO2 capture is an important area of research. The predominant process for CO2 capture currently employed by industry is chemical absorption in amine solutions. A dynamic model for the de-absorption process was developed with monoethanolamine (MEA) solution. Henry's law was used for modelling the vapour phase equilibrium of the CO2, and fugacity ratios calculated by the Peng-Robinson equation of state (EOS) were used for H2O, MEA, N2 and O2. Chemical reactions between CO2 and MEA were included in the model along with the enhancement factor for chemical absorption. Liquid and vapour energy balances were developed to calculate the liquid and vapour temperature, respectively.

  19. Influence of the temperature on the (liquid + liquid) phase equilibria of (water + 1-propanl + linalool or geraniol)

    International Nuclear Information System (INIS)

    Wan, Li; Li, Hengde; Huang, Cheng; Feng, Yuqing; Chu, Guoqiang; Zheng, Yuying; Tan, Wei; Qin, Yanlin; Sun, Dalei; Fang, Yanxiong

    2017-01-01

    Highlights: • Ternary LLEs containing linalool and geraniol are presented. • Distribution ratios of 1-propanol in the mixtures are examined. • Influence of the temperature on the LLE is studied. • The LLE data were correlated using the NRTL and UNIQUAC models. - Abstract: Linalool and geraniol are the primary components of rose oil, palmarosa oil, and citronella oil and many other essential oils, and two important compounds used in the flavour and fragrance, cosmetic or pharmaceutical industries. Phase equilibria (LLE, VLE, solubility, etc.) and related thermodynamic properties of a mixture are essential in the processes design and control of mass transfer process. In this work, experimental (liquid + liquid) equilibria data of the systems (water + 1-propanl + linalool) and (water + 1-propanl + geraniol) are presented. The (liquid + liquid) equilibria of both systems were determined with a tie-line method at T = (283.15, 298.15 and 313.15) K under atmospheric pressure. The well-known Hand, Bachman and Othmer–Tobias equations were used to test the reliability of the experimental values. The influence of the temperature on the (liquid + liquid) phase equilibria of the mixtures, the binodal curves and distribution ratios of 1-propanl are shown and discussed. Moreover, the NRTL and UNIQUAC models were applied to fit the data for both ternary systems. The interaction parameters obtained from both models successfully correlated the equilibrium compositions. Furthermore, the ternary systems could be represented using the binary parameters of the thermodynamic model with a function of temperature.

  20. Domain-adaptive finite difference methods for collapsing annular liquid jets

    Science.gov (United States)

    Ramos, J. I.

    1993-01-01

    A domain-adaptive technique which maps a time-dependent, curvilinear geometry into a unit square is used to determine the steady state mass absorption rate and the collapse of annular liquid jets. A method of lines is used to solve the one-dimensional fluid dynamics equations written in weak conservation-law form, and upwind differences are employed to evaluate the axial convective fluxes. The unknown, time-dependent, axial location of the downstream boundary is determined from the solution of an ordinary differential equation which is nonlinearly coupled to the fluid dynamics and gas concentration equations. The equation for the gas concentration in the annular liquid jet is written in strong conservation-law form and solved by means of a method of lines at high Peclet numbers and a line Gauss-Seidel method at low Peclet numbers. The effects of the number of grid points along and across the annular jet, time step, and discretization of the radial convective fluxes on both the steady state mass absorption rate and the jet's collapse rate have been analyzed on staggered and non-staggered grids. The steady state mass absorption rate and the collapse of annular liquid jets are determined as a function of the Froude, Peclet and Weber numbers, annular jet's thickness-to-radius ratio at the nozzle exit, initial pressure difference across the annular jet, nozzle exit angle, temperature of the gas enclosed by the annular jet, pressure of the gas surrounding the jet, solubilities at the inner and outer interfaces of the annular jet, and gas concentration at the nozzle exit. It is shown that the steady state mass absorption rate is proportional to the inverse square root of the Peclet number except for low values of this parameter, and that the possible mathematical incompatibilities in the concentration field at the nozzle exit exert a great influence on the steady state mass absorption rate and on the jet collapse. It is also shown that the steady state mass absorption

  1. Single uniform FBG for simultaneous measurement of liquid level and temperature

    International Nuclear Information System (INIS)

    Shu, Xuewen; Sugden, Kate; Bennion, Ian

    2010-01-01

    In this paper, we propose and demonstrate a novel scheme for simultaneous measurement of liquid level and temperature based on a simple uniform fiber Bragg grating (FBG) by monitoring both the short-wavelength-loss peaks and its Bragg resonance. The liquid level can be measured from the amplitude changes of the short-wavelength-loss peaks, while temperature can be measured from the wavelength shift of the Bragg resonance. Both theoretical simulation results and experimental results are presented. Such a scheme has some advantages including robustness, simplicity, flexibility in choosing sensitivity and simultaneous temperature measurement capability

  2. Intestinal absorption of dietary fat from a liquid diet perfused in rats at a submaximum level

    International Nuclear Information System (INIS)

    Simko, V.; Kelley, R.E.

    1988-01-01

    The small intestine of rats was perfused in vivo for 2 h with a nutritionally complete liquid diet (68% calories from fat as corn oil). As the perfusion increased from 106 mg/2 h, the intestinal disappearance of the 14 C-triolein marker remained proportional to the load up to 2359 mg fat/2 h. Despite a decrease in absorption from 70 to 17%, this represents a very large fat intake. Fat absorption improved when medium-chain triglycerides or octanoic acid replaced corn oil (both p less than 0.01). Linoleic acid was absorbed from the diet less than corn oil (p less than 0.01). Dry ox bile reduced fat absorption (p less than 0.05); lipase and an antacid had no effect. Corn oil perfused alone was absorbed better than from the diet (p less than 0.01). Data with 14 C-triolein was confirmed by dry-weight disappearance of the diet and by net intestinal water balance. Usual feeding underutilizes a large reserve for fat absorption. This reserve should be considered in therapeutic nutrition

  3. Direct observation of effective temperature of Ta atom in layer compound TaS2 by neutron resonance absorption spectrometer

    International Nuclear Information System (INIS)

    Tokuda, Koji; Kamiyama, Takashi; Kiyanagi, Yoshiaki; Moreh, R.; Ikeda, Susumu

    2001-01-01

    A neutron resonance absorption spectrometer, DOG has been installed at KENS, High Energy Accelerator Research Organization Neutron Source, which enables us to investigate the motions of a particular element by analyzing the line width of resonance absorption spectrum. We measured the temperature dependence of the effective temperature of Ta motion in TaS 2 as well as in Ta metal using DOG. The effective temperatures extracted from the observed absorption spectrum agree well with the calculated values from the phonon density of states of Ta metal over a wide temperature range of 10 to 300 K. We also succeeded in measuring both the angular dependence and the temperature dependence of effective temperatures of Ta in a layer compound TaS 2 . Based on the temperature dependence of the effective temperature, the partial phonon density of states of Ta in TaS 2 was discussed. (author)

  4. Temperature-induced structural changes in fluorozirconate glasses and liquids

    International Nuclear Information System (INIS)

    Sen, S.; Youngman, R.E.

    2002-01-01

    The atomic structure and its temperature dependence in fluorozirconate glasses and supercooled liquids have been studied with high-resolution and high-temperature 19 F and 23 Na nuclear-magnetic-resonance (NMR) spectroscopy. The 19 F NMR spectra in these glasses show the presence of multiple F environments. Temperature dependence of the 19 F magic-angle-spinning NMR spectra indicates a progressive change in the average F coordination environment in the glass structure, besides motional narrowing due to substantial mobility of F - ions. The observed change in the average 19 F NMR chemical shift is consistent with progressive breaking of the Zr-F-Zr linkages in the glass structure with increasing temperature. The onset of such a change in F speciation is observed at temperatures well below T g . This result is evidence of changes in the average equilibrium structure in an inorganic glass-forming liquid at T g , albeit on a local scale. The 23 Na NMR spectra indicate that the cations in these glasses become significantly mobile only at temperatures T≥T g , which allows for the onset of global structural relaxation and viscous flow

  5. (Liquid + liquid) equilibria of {benzene + cyclohexane + two ionic liquids} at different temperature and atmospheric pressure

    International Nuclear Information System (INIS)

    Sakal, Salem A.; Shen, Chong; Li, Chun-xi

    2012-01-01

    Highlights: ► (Liquid + liquid) equilibrium for two quaternary and two ternary systems were measured. ► The components include cyclohexane, benzene, [MIM][BF4], [MIM][ClO4] and [MMIM][DMP]. ► The (liquid + liquid) equilibrium data can be well correlated by the NRTL model. ► Separation of benzene and cyclohexane by pure ILs and their mixtures were discussed. - Abstract: (Liquid + liquid) equilibrium data of the following ternary and quaternary systems at different temperatures and mass fractions of ionic liquids (ILs) were measured at atmospheric pressure, i.e., {cyclohexane + benzene + 1,3-dimethylimidazolium dimethylphosphate ([MMIM][DMP])} at 298.2 K, {cyclohexane + benzene + 1-methylimidazolium tetrafluoroborate ([MIM][BF 4 ])} at 338.2 K, {cyclohexane + benzene + [MIM][BF 4 ] + [MMIM][DMP]} at (298.2 and 313.2) K, and {cyclohexane + benzene + 1-methylimidazolium perchlorate [MIM][ClO 4 ] + [MMIM][DMP]} at 298.2 K. The results indicate that both selectivity and distribution factor of the IL mixture for benzene are lower than that of pure IL [MMIM][DMP] at a specified condition, and decrease with the increase of the mass fraction of [MIM][BF 4 ] or [MIM][ClO 4 ] in its mixture of [MMIM][DMP] and the mole fraction of benzene. The extremely high selectivity of [MIM][BF 4 ] and [MIM][ClO 4 ] for aromatic compounds as predicted by the COSMOS-RS model is not justified by the present experimental results, and on the contrary, they show a relatively lower selectivity and extraction capacity for benzene than [MMIM][DMP].

  6. The Effect of Temperature on Cr (VI) Removal by Using Guava Leaves as a Biosorbent

    OpenAIRE

    Mariana,; Mulana, Farid

    2013-01-01

    Preliminary research on Cr(IV) removal in a liquid waste using guava leaves (Psidium Guajava) as a bio-sorbent has been done. The experiments were conducted in a stirred batch reactor. The effect of temperature on efficiency and absorption capacity has been studied. Both the efficiency and absorptioncapacity are directly proportional to the temperature under the current experimental conditions. The results showed that optimum absorption capacity and absorption efficiency of Cr(VI) use of guav...

  7. Transport properties of glass-forming liquids suggest that dynamic crossover temperature is as important as the glass transition temperature.

    Science.gov (United States)

    Mallamace, Francesco; Branca, Caterina; Corsaro, Carmelo; Leone, Nancy; Spooren, Jeroen; Chen, Sow-Hsin; Stanley, H Eugene

    2010-12-28

    It is becoming common practice to partition glass-forming liquids into two classes based on the dependence of the shear viscosity η on temperature T. In an Arrhenius plot, ln η vs 1/T, a strong liquid shows linear behavior whereas a fragile liquid exhibits an upward curvature [super-Arrhenius (SA) behavior], a situation customarily described by using the Vogel-Fulcher-Tammann law. Here we analyze existing data of the transport coefficients of 84 glass-forming liquids. We show the data are consistent, on decreasing temperature, with the onset of a well-defined dynamical crossover η(×), where η(×) has the same value, η(×) ≈ 10(3) Poise, for all 84 liquids. The crossover temperature, T(×), located well above the calorimetric glass transition temperature T(g), marks significant variations in the system thermodynamics, evidenced by the change of the SA-like T dependence above T(×) to Arrhenius behavior below T(×). We also show that below T(×) the familiar Stokes-Einstein relation D/T ∼ η(-1) breaks down and is replaced by a fractional form D/T ∼ η(-ζ), with ζ ≈ 0.85.

  8. Temperature control system for liquid-fed ceramic melters

    International Nuclear Information System (INIS)

    Westsik, J.H. Jr.

    1986-10-01

    A temperature-feedback system has been developed for controlling electrical power to liquid-fed ceramic melters (LFCM). Software, written for a microcomputer-based data acquisition and process monitoring system, compares glass temperatures with a temperature setpoint and adjusts the electrical power accordingly. Included in the control algorithm are steps to reject failed thermocouples, spatially average the glass temperatures, smooth the averaged temperatures over time using a digital filter, and detect foaming in the glass. The temperature control system has proved effective during all phases of melter operation including startup, steady operation, loss of feed, and shutdown. This system replaces current, power, and resistance feedback control systems used previously in controlling the LFCM process

  9. Near-infrared diode laser absorption diagnostic for temperature and water vapor in a scramjet combustor

    International Nuclear Information System (INIS)

    Liu, Jonathan T.C.; Rieker, Gregory B.; Jeffries, Jay B.; Gruber, Mark R.; Carter, Campbell D.; Mathur, Tarun; Hanson, Ronald K.

    2005-01-01

    Tunable diode laser absorption measurements of gas temperature and water concentration were made at the exit of a model scramjet combustor fueled on JP-7. Multiplexed, fiber-coupled, near-infrared distributed feedback lasers were used to probe three water vapor absorption features in the 1.34-1.47 μm spectral region (2v1and v1+ v3overtone bands). Ratio thermometry was performed using direct-absorption wavelength scans of isolated features at a 4-kHz repetition rate, as well as 2f wavelength modulation scans at a 2-kHz scan rate. Large signal-to-noise ratios demonstrate the ability of the optimally engineered optical hardware to reject beam steering and vibration noise. Successful measurements were made at full combustion conditions for a variety of fuel/air equivalence ratios and at eight vertical positions in the duct to investigate spatial uniformity. The use of three water vapor absorption features allowed for preliminary estimates of temperature distributions along the line of sight. The improved signal quality afforded by 2f measurements, in the case of weak absorption, demonstrates the utility of a scanned wavelength modulation strategy in such situations

  10. Nonlinear intersubband absorption and refractive index changes in square and graded quantum well modulated by temperature and Hydrostatic pressure

    International Nuclear Information System (INIS)

    Ozturk, Emine; Sokmen, Ismail

    2013-01-01

    In this study, the effects of hydrostatic pressure and temperature on the linear and nonlinear intersubband transitions and the refractive index changes in the conduction band of square and graded quantum well (QW) are theoretically calculated within the framework of effective mass approximation. Results obtained show that the energy levels in different QWs and intersubband properties can be modified and controlled by the hydrostatic pressure and temperature. The modulation of the absorption coefficients and the refractive index changes which can be suitable for good performance optical modulators and various infrared optical device applications can be easily obtained by tuning the temperature and the hydrostatic pressure. - Highlights: ► Linear and nonlinear optical processes can be changed by pressure and temperature. ► Magnitude and energy of absorption peaks decrease as pressure increases. ► Refractive index changes in magnitude and energy decrease by increasing pressure. ► Energy differences are dependent on pressure, temperature and QW shapes. ► By increasing pressure we can obtain redshift in the optical transitions. ► For SQW, the absorption spectrum shows blueshift as the temperature increases. ► For GQW, the absorption spectrum shows redshift by temperature.

  11. Evidence for a temperature-driven structural transformation in liquid bismuth

    International Nuclear Information System (INIS)

    Greenberg, Y.; Dariel, M.P.; Greenberg, Y.; Yahel, E.; Caspi, E.N.; Makov, G.; Benmore, C.; Beuneu, B.

    2009-01-01

    The thermodynamic properties of liquid bismuth have been explored from the melting point to 1100 C degrees by high-resolution measurements of the density, the heat capacity and the static structure factor. These physical properties display a number of anomalies. In particular, we have observed evidence for the presence of a temperature-driven liquid-liquid structural transformation that takes place at ambient pressure. The latter is characterized by a density discontinuity that occurs at 740 C degrees. Differential thermal analysis measurements revealed the endo-thermal nature of this transformation. A rearrangement of liquid bismuth structure was found by neutron diffraction measurements, supporting the existence of a liquid-liquid transformation far above the liquidus. (authors)

  12. Direct high-temperature ohmic heating of metals as liquid pipes.

    Science.gov (United States)

    Grosse, A V; Cahill, J A; Liddell, W L; Murphy, W J; Stokes, C S

    1968-05-03

    When a sufficiently high electric current is passed through a liquid metal, the electromagnetic pressure pinches off the liquid metal and interrupts the flow of current. For the first time the pinch effect has been overcome by use of centrifugal acceleration. By rotation of a pipe of liquid metal, tin or bismuth or their alloys, at sufficiently high speed, it can be heated electrically without intermission of the electric current. One may now heat liquid metallic substances, by resistive (ohmic) heating, to 5000 degrees K and perhaps higher temperatures.

  13. Engineering: Liquid metal pumped at a record temperature

    Science.gov (United States)

    Lambrinou, Konstantina

    2017-10-01

    Although liquid metals are effective fluids for heat transfer, pumping them at high temperatures is limited by their corrosiveness to solid metals. A clever pump design addresses this challenge using only ceramics. See Article p.199

  14. Liquid-liquid miscibility and volumetric properties of aqueous solutions of ionic liquids as a function of temperature

    International Nuclear Information System (INIS)

    Wang Silu; Jacquemin, Johan; Husson, Pascale; Hardacre, Christopher; Costa Gomes, Margarida F.

    2009-01-01

    The volumetric properties of seven {water + ionic liquid} binary mixtures have been studied as a function of temperature from (293 to 343) K. The phase behaviour of the systems was first investigated using a nephelometric method and excess molar volumes were calculated from densities measured using an Anton Paar densimeter and fitted using a Redlich-Kister type equation. Two ionic liquids fully miscible with water (1-butyl-3-methylimidazolium tetrafluoroborate ([C 1 C 4 Im][BF 4 ]) and 1-ethyl-3-methylimidazolium ethylsulfate ([C 1 C 2 Im][EtSO 4 ])) and five ionic liquids only partially miscible with water (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C 1 C 2 Im][NTf 2 ]), 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C 1 C 4 Im][NTf 2 ]), 1-butyl-3-methylimidazolium hexafluorophosphate ([C 1 C 4 Im][PF 6 ]), 1-butyl-3-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ([C 1 C 4 Pyrro][NTf 2 ]), and butyltrimethylammonium bis(trifluoromethylsulfonyl)imide ([N 4111 ][NTf 2 ])) were chosen. Small excess volumes (less than 0.5 cm 3 . mol -1 at 298 K) are obtained compared with the molar volumes of the pure components (less than 0.3% of the molar volume of the pure ionic liquid). For all the considered systems, except for {[C 1 C 2 Im][EtSO 4 ] + water}, positive excess molar volumes were calculated. Finally, an increase of the non-ideality character is observed for all the systems as temperature increases.

  15. High temperature absorption compression heat pump for industrial waste heat

    DEFF Research Database (Denmark)

    Reinholdt, Lars; Horntvedt, B.; Nordtvedt, S. R.

    2016-01-01

    Heat pumps are currently receiving extensive interest because they may be able to support the integration of large shares of fluctuating electricity production based on renewable sources, and they have the potential for the utilization of low temperature waste heat from industry. In most industries......, the needed temperature levels often range from 100°C and up, but until now, it has been quite difficult to find heat pump technologies that reach this level, and thereby opening up the large-scale heat recovery in the industry. Absorption compression heat pumps can reach temperatures above 100°C......, and they have proved themselves a very efficient and reliable technology for applications that have large temperature changes on the heat sink and/or heat source. The concept of Carnot and Lorenz efficiency and its use in the analysis of system integration is shown. A 1.25 MW system having a Carnot efficiency...

  16. Wine absorption by cork stoppers research in foods

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Adrados, J. R.; Gonzalez-Hernandez, F.; Garcia de Ceca, J. L.; Caceres-Esteban, M. J.; Garcia-Vallejo, M. C.

    2008-07-01

    To evaluate the magnitude of wine absorption by cork under conditions as close to reality as possible and its evolution in time, ready-to-use natural cork stoppers and ''1+1'' cork stoppers were used to close bottles filled with red wine. Stoppers were removed after 3, 6, 12 and 24 months of contact to determine absorption of liquid and liquid progression along the lateral surface of the cork stopper.Variation of absorption with contact time was studied by adjusting the model Absorption = a {radical} t(R{sup 2}: 82.19 - 93.63%). A scheme of the evolution of wine absorption with time is proposed, differentiating liquid flow along cork-glass interface, diffusion in cell walls and liquid flow through the cell lumens. In conditions of use, a value of 4.48.10{sup 1}3 m{sup 2} s{sup -}1 was obtained for non-radial diffusion coefficient (D). (Author) 13 refs.

  17. The Advanced High-Temperature Reactor (AHTR) for Producing Hydrogen to Manufacture Liquid Fuels

    International Nuclear Information System (INIS)

    Forsberg, C.W.; Peterson, P.F.; Ott, L.

    2004-01-01

    Conventional world oil production is expected to peak within a decade. Shortfalls in production of liquid fuels (gasoline, diesel, and jet fuel) from conventional oil sources are expected to be offset by increased production of fuels from heavy oils and tar sands that are primarily located in the Western Hemisphere (Canada, Venezuela, the United States, and Mexico). Simultaneously, there is a renewed interest in liquid fuels from biomass, such as alcohol; but, biomass production requires fertilizer. Massive quantities of hydrogen (H2) are required (1) to convert heavy oils and tar sands to liquid fuels and (2) to produce fertilizer for production of biomass that can be converted to liquid fuels. If these liquid fuels are to be used while simultaneously minimizing greenhouse emissions, nonfossil methods for the production of H2 are required. Nuclear energy can be used to produce H2. The most efficient methods to produce H2 from nuclear energy involve thermochemical cycles in which high-temperature heat (700 to 850 C) and water are converted to H2 and oxygen. The peak nuclear reactor fuel and coolant temperatures must be significantly higher than the chemical process temperatures to transport heat from the reactor core to an intermediate heat transfer loop and from the intermediate heat transfer loop to the chemical plant. The reactor temperatures required for H2 production are at the limits of practical engineering materials. A new high-temperature reactor concept is being developed for H2 and electricity production: the Advanced High-Temperature Reactor (AHTR). The fuel is a graphite-matrix, coated-particle fuel, the same type that is used in modular high-temperature gas-cooled reactors (MHTGRs). The coolant is a clean molten fluoride salt with a boiling point near 1400 C. The use of a liquid coolant, rather than helium, reduces peak reactor fuel and coolant temperatures 100 to 200 C relative to those of a MHTGR. Liquids are better heat transfer fluids than gases

  18. Density of Liquid Steel over Temperature Range of 1 803-1 873 K

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang

    2004-01-01

    The density of three kinds of liquid steel was measured by a modified sessile drop method over the temperature range of 1 803-1 873 K. It is found that the density of liquid steels decreases with increasing temperature and carbon content in steel. Both of the density and its absolute temperature coefficient of studied steels are smaller than the literature values of pure iron. The molar volume of the steels increases with increasing temperature.

  19. Moisture Absorption of Epoxy Matrix Composites Immersed in Liquids and in Humid Air.

    Science.gov (United States)

    1979-10-01

    Eq. 4). -34- TEMPERATURE, T (K) 165 40 350 300 Neat ResinA / Fit to Data 0\\ 0 o Composite Calculated 0- Data Delasi and Whiteside (1977) 168 AS/3501...moisture ab - sorption characteristics of T300/1034, AS/3501-5 and T300/5208 graphite-epoxy composites. 1) Material immersed in liquid at temperatures 300 to

  20. Thermodynamic modelling and parametric study of a low temperature vapour compression-absorption system based on modified Gouy-Stodola equation

    International Nuclear Information System (INIS)

    Jain, Vaibhav; Sachdeva, Gulshan; Kachhwaha, S.S.

    2015-01-01

    Present paper thermodynamically analyses a VCAS (vapour compression-absorption system) with carbon dioxide (compression section) and ammonia-water (absorption section) as refrigerants and determines the optimal condensing temperature of cascade condenser using modified Gouy-Stodola equation. The optimum cascade condenser temperature is found to be −13 °C for 175 kW refrigeration capacity at an evaporator temperature of −45 °C and condenser temperature of 35 °C. The optimum cascade condenser temperature maximises the overall COP, rational efficiency and minimises the total irreversibility rate of the VCAS system. The value of optimum condensing temperature and its corresponding maximum COP, and minimum irreversibility rate are discussed for a wide range of operating conditions. Further, a comparative study of TSVCS (two stage vapour compression system) used for low temperature refrigeration applications with VCAS shows that at design point, primary energy consumption is reduced by 60.6% and electrical COP is improved by 153.6% in VCAS as compared to conventional TSVCS. But the total irreversibility rate of VCAS is 38.4% higher than the TSVCS due to the use of low grade energy in vapour absorption system and hence the rational efficiency of VCAS is 14% low. - Highlights: • Optimum cascade condenser temperature with modified Gouy-Stodola law is analysed. • It maximises COP, rational efficiency and minimises total irreversibility. • 60.6% of primary energy is saved by cascaded absorption system. • Electrical COP is improved by 153.6% with cascaded absorption system

  1. Liquid temperature measuring method and device therefor

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Fumi; Karasawa, Hirokazu

    1995-06-02

    In the present invention, temperature of liquid metal in coolants in an FBR type reactor can accurately be measured at rapid response time. Namely, ultrasonic waves are emitted from an ultrasonic wave sensor disposed in the air to a guide wave tube. Ultrasonic waves are reflected at reflection plates disposed at front and back or upper and lower portions of a small hole disposed to the wave guide tube. The reflected waves are received by the sensor described above. The difference of the reaching time of the reflected waves from the reflecting plates disposed at the front and the back or the upper and lower portions is measured. The speed of sounds in this case is determined based on the size of the small hole and the distance of the upper and the lower reflection plates. The speed of sounds is determined by the formula below: V(m/s) = 2500 - 0.52 T, where T: temperature. The temperature of the liquid can easily be calculated based on the formula. Accordingly, since the speed of the ultrasonic waves from their emission to the reception is msec order, and the processing of the signals are simple, the temperature can be measured at a response time of several msecs. In addition, since the ultrasonic wave sensor is disposed at the outside of the reactor, no special countermeasure for environmental circumstances is necessary, to improve maintenance ability. (I.S.).

  2. Temperature dependence of the optical absorption spectra of InP/ZnS quantum dots

    Science.gov (United States)

    Savchenko, S. S.; Vokhmintsev, A. S.; Weinstein, I. A.

    2017-03-01

    The optical-absorption spectra of InP/ZnS (core/shell) quantum dots have been studied in a broad temperature range of T = 6.5-296 K. Using the second-order derivative spectrophotometry technique, the energies of optical transitions at room temperature were found to be E 1 = 2.60 ± 0.02 eV (for the first peak of excitonic absorption in the InP core) and E 2 = 4.70 ± 0.02 eV (for processes in the ZnS shell). The experimental curve of E 1( T) has been approximated for the first time in the framework of a linear model and in terms of the Fan's formula. It is established that the temperature dependence of E 1 is determined by the interaction of excitons and longitudinal acoustic phonons with hω = 15 meV.

  3. Salt-assisted liquid-liquid microextraction of Cr(VI) ion using an ionic liquid for preconcentration prior to its determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Majidi, B.; Shemirani, F.

    2012-01-01

    We report on the salt-assisted liquid-liquid microextraction of cationic complexes of Cr(VI) ion using the hydrophilic ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoraborate and potassium hydrogen phosphate. This is a novel, simple, non-toxic and effective technique for sample pretreatment technique that displays large extraction efficiency and represents a new platform where Cr(VI) is complexed with 1,5-diphenylcarbazide (DPC) in sulfuric acid medium. It was applied to the extraction of Cr(VI) in the form of the Cr(VI)-DPC complex prior to its determination by flame atomic absorption spectrometry. Cr(III) ion also can be determined by this procedure after oxidation to Cr(VI). Extraction is mainly affected by the amount of water-soluble IL, the kind and quantity of inorganic salts, by pH and the concentration of DPC. Calibration plots are linear in the range from 3 to 150 μg L -1 of Cr(VI), and the limit of detection is 1. 25 μg L -1 . The method was successfully applied to the speciation and determination of trace levels of Cr(III) and Cr(VI) in environmental water samples containing high levels of dissolved salts or food grade salts. (author)

  4. Effect of water vapour absorption on hydroxyl temperatures measured from Svalbard

    Directory of Open Access Journals (Sweden)

    J. M. Chadney

    2017-03-01

    Full Text Available We model absorption by atmospheric water vapour of hydroxyl airglow emission using the HIgh-resolution TRANsmission molecular absorption database (HITRAN2012. Transmission coefficients are provided as a function of water vapour column density for the strongest OH Meinel emission lines in the (8–3, (5–1, (9–4, (8–4, and (6–2 vibrational bands. These coefficients are used to determine precise OH(8–3 rotational temperatures from spectra measured by the High Throughput Imaging Echelle Spectrograph (HiTIES, installed at the Kjell Henriksen Observatory (KHO, Svalbard. The method described in this paper also allows us to estimate atmospheric water vapour content using the HiTIES instrument.

  5. Thermoluminescent system for low temperatures

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.; Leite, N.G.

    1988-09-01

    A system for measurements of the thermoluminescent glow curve, the thermoluminescent emission spectrum and the optical absorption spectrum of solid samples, from liquid nitrogen temperature up to 473 K, is reported. A specially designed temperature programmer provides a linear heating of the sample at a wide range of selectable heating rates, as also long term steady-state temperatures for annealing and isothermal decay studies. The system operates at a pressure of 1.33 x 10 -3 Pa. Presently it is being used for lithium fluoride low temperature thermoluminescent studies. (author) [pt

  6. Above band gap absorption spectra of the arsenic antisite defect in low temperature grown GaAs and AlGaAs

    DEFF Research Database (Denmark)

    Dankowski, S. U.; Streb, D.; Ruff, M.

    1996-01-01

    coefficients at the band gap are twice as high as for high temperature grown materials. By annealing the samples, we obtained a drastic reduced absorption coefficient below as well as above the band gap. We observed absorption changes up to 17 000 cm(-1) for LT-GaAs and 9000 cm(-1) for LT-AlGaAs taking place......Room temperature absorption spectra of low temperature molecular beam epitaxy grown GaAs (LT-GaAs) and AlGaAs (LT-AlGaAs) are reported. We performed measurements in an extended spectral range from 0.8 eV to photon energies of 2.8 eV far above the band gap. For as-grown LT-materials, the absorption...

  7. A Novel High-Sensitivity, Low-Power, Liquid Crystal Temperature Sensor

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2014-04-01

    Full Text Available A novel temperature sensor based on nematic liquid crystal permittivity as a sensing magnitude, is presented. This sensor consists of a specific micrometric structure that gives considerable advantages from other previous related liquid crystal (LC sensors. The analytical study reveals that permittivity change with temperature is introduced in a hyperbolic cosine function, increasing the sensitivity term considerably. The experimental data has been obtained for ranges from −6 °C to 100 °C. Despite this, following the LC datasheet, theoretical ranges from −40 °C to 109 °C could be achieved. These results have revealed maximum sensitivities of 33 mVrms/°C for certain temperature ranges; three times more than of most silicon temperature sensors. As it was predicted by the analytical study, the micrometric size of the proposed structure produces a high output voltage. Moreover the voltage’s sensitivity to temperature response can be controlled by the applied voltage. This response allows temperature measurements to be carried out without any amplification or conditioning circuitry, with very low power consumption.

  8. Quantum chemical aided prediction of the thermal decomposition mechanisms and temperatures of ionic liquids

    International Nuclear Information System (INIS)

    Kroon, Maaike C.; Buijs, Wim; Peters, Cor J.; Witkamp, Geert-Jan

    2007-01-01

    The long-term thermal stability of ionic liquids is of utmost importance for their industrial application. Although the thermal decomposition temperatures of various ionic liquids have been measured previously, experimental data on the thermal decomposition mechanisms and kinetics are scarce. It is desirable to develop quantitative chemical tools that can predict thermal decomposition mechanisms and temperatures (kinetics) of ionic liquids. In this work ab initio quantum chemical calculations (DFT-B3LYP) have been used to predict thermal decomposition mechanisms, temperatures and the activation energies of the thermal breakdown reactions. These quantum chemical calculations proved to be an excellent method to predict the thermal stability of various ionic liquids

  9. High-temperature measurements of methane and acetylene using quantum cascade laser absorption near 8 μm

    International Nuclear Information System (INIS)

    Sajid, M.B.; Javed, T.; Farooq, A.

    2015-01-01

    The mid-infrared wavelength region near 8 μm contains absorption bands of several molecules such as water vapor, hydrogen peroxide, nitrous oxide, methane and acetylene. A new laser absorption sensor based on the ν 4 band of methane and the ν 4 +ν 5 band of acetylene is reported for interference-free, time-resolved measurements under combustion-relevant conditions. A detailed line-selection procedure was used to identify optimum transitions. Methane and acetylene were measured at the line centers of Q12 (1303.5 cm −1 ) and P23 (1275.5 cm −1 ) transitions, respectively. High-temperature absorption cross sections of methane and acetylene were measured at peaks (on-line) and valleys (off-line) of the selected absorption transitions. The differential absorption strategy was employed to eliminate interference absorption from large hydrocarbons. Experiments were performed behind reflected shock waves over a temperature range of 1200–2200 K, between pressures of 1–4 atm. The diagnostics were then applied to measure the respective species time-history profiles during the shock-heated pyrolysis of n-pentane. - Highlights: • Methane measured at the peak of Q(12) transition in the ν 4 band. • Acetylene measured at the peak of P(23) transition in the ν 4 +ν 5 band. • Differential absorption strategy employed to eliminate broadband interference absorption. • Absorption cross-sections measured over 1200–2200 K and 1–4 atm. • Methane and acetylene time-histories measured during the pyrolysis of n-pentane

  10. Transitions through critical temperatures in nematic liquid crystals

    KAUST Repository

    Majumdar, Apala; Ockendon, John; Howell, Peter; Surovyatkina, Elena

    2013-01-01

    We obtain estimates for critical nematic liquid crystal (LC) temperatures under the action of a slowly varying temperature-dependent control variable. We show that biaxiality has a negligible effect within our model and that these delay estimates are well described by a purely uniaxial model. The static theory predicts two critical temperatures: the supercooling temperature below which the isotropic phase loses stability and the superheating temperature above which the ordered nematic states do not exist. In contrast to the static problem, the isotropic phase exhibits a memory effect below the supercooling temperature in the dynamic framework. This delayed loss of stability is independent of the rate of change of temperature and depends purely on the initial value of the temperature. We also show how our results can be used to improve estimates for LC material constants. © 2013 American Physical Society.

  11. Transitions through critical temperatures in nematic liquid crystals

    KAUST Repository

    Majumdar, Apala

    2013-08-06

    We obtain estimates for critical nematic liquid crystal (LC) temperatures under the action of a slowly varying temperature-dependent control variable. We show that biaxiality has a negligible effect within our model and that these delay estimates are well described by a purely uniaxial model. The static theory predicts two critical temperatures: the supercooling temperature below which the isotropic phase loses stability and the superheating temperature above which the ordered nematic states do not exist. In contrast to the static problem, the isotropic phase exhibits a memory effect below the supercooling temperature in the dynamic framework. This delayed loss of stability is independent of the rate of change of temperature and depends purely on the initial value of the temperature. We also show how our results can be used to improve estimates for LC material constants. © 2013 American Physical Society.

  12. Investigating the solvent and temperature effects on the cyclohexadienyl radical in an ionic liquid

    International Nuclear Information System (INIS)

    Taylor, Becky; Cormier, P.J.; Lauzon, J.M.; Ghandi, Khashayar

    2009-01-01

    The cyclohexadienyl radical was studied in a novel green solvent; tetradecyl (trihexyl) phosphonium chloride ionic liquid (IL 101). Both the solvent effects and how the hyperfine coupling changes with respect to temperature have been examined and compared to literature. This was done through experimental muon techniques at the TRIUMF National Laboratory in Canada as well as through ab initio calculations. The ionic liquid solvent effects were found to be consistent with other solvents, when assuming ionic liquids to be a combination of ion pairs. In ionic liquid the hyperfine coupling constants of the proton and reduced muon decreased linearly with increasing temperature. The analysis showed that the majority of this relationship is due to a vibrational effect, although the solvent density plays a role too. The temperature effect on the entropy of the system was determined to be negligible. The temperature coefficient of the reduced muon hyperfine coupling was larger than that of the proton in IL 101 due to the effects of nearby ionic liquid molecules.

  13. Investigating the solvent and temperature effects on the cyclohexadienyl radical in an ionic liquid

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Becky; Cormier, P.J.; Lauzon, J.M. [Department of Chemistry, Mount Allison University, Sackville, New Brunswick, E4L 1G3 (Canada); Ghandi, Khashayar, E-mail: kghandi@mta.c [Department of Chemistry, Mount Allison University, Sackville, New Brunswick, E4L 1G3 (Canada)

    2009-04-15

    The cyclohexadienyl radical was studied in a novel green solvent; tetradecyl (trihexyl) phosphonium chloride ionic liquid (IL 101). Both the solvent effects and how the hyperfine coupling changes with respect to temperature have been examined and compared to literature. This was done through experimental muon techniques at the TRIUMF National Laboratory in Canada as well as through ab initio calculations. The ionic liquid solvent effects were found to be consistent with other solvents, when assuming ionic liquids to be a combination of ion pairs. In ionic liquid the hyperfine coupling constants of the proton and reduced muon decreased linearly with increasing temperature. The analysis showed that the majority of this relationship is due to a vibrational effect, although the solvent density plays a role too. The temperature effect on the entropy of the system was determined to be negligible. The temperature coefficient of the reduced muon hyperfine coupling was larger than that of the proton in IL 101 due to the effects of nearby ionic liquid molecules.

  14. Comparative studies of H absorption/desorption kinetics and evaporation of liquid lithium in different porous systems and free surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Oyarzabal, E., E-mail: eider.oyarzabal@externos.ciemat.es [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); Calle de Guzmán el Bueno, 133, 28003 Madrid (Spain); Martín-Rojo, A.B. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); Calle de Guzmán el Bueno, 133, 28003 Madrid (Spain); Tabarés, F.L. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain)

    2017-04-15

    In the present work, a study of the two most relevant properties of liquid lithium with respect to its suitability as a Plasma Facing Component (PFC) element in a Reactor, namely, its evaporation rate and the uptake/release of hydrogen, eventually leading to the formation of a stable hydride was carried out for Li in different porous systems and Li as a free surface. These properties were characterized in a temperature range of 200–500 °C. The H{sub 2} absorption kinetics at low pressure (<1torr) were measured for the different studied porous systems and then outgassed. Particle balance and chemical analysis were used to assess the retention properties of lithium for each case. Thermal Desorption Spectroscopy (TDS) analysis was used for the assessment of possible hydride formation. Evaporation rates were determined by using a Quartz Microbalance (QMB). A significant reduction of the evaporation rate was observed when Li was trapped in a microstructure of sintered stainless steel with a characteristic porous size of 5–10 μm. On the other hand, a negligible rate of H{sub 2} uptake was found at temperatures above 500 °C in all cases.

  15. Ion chromatography with the indirect ultraviolet detection of alkali metal ions and ammonium using imidazolium ionic liquid as ultraviolet absorption reagent and eluent.

    Science.gov (United States)

    Liu, Yong-Qiang; Yu, Hong

    2016-08-01

    Indirect ultraviolet detection was conducted in ultraviolet-absorption-agent-added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li(+) , Na(+) , K(+) , and NH4 (+) was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography-indirect ultraviolet detection. The successful separation and detection of Li(+) , Na(+) , K(+) , and NH4 (+) within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature

    CERN Document Server

    Baibussinov, B; Casagrande, F; Cennini, P; Centro, S; Curioni, A; Meng, G; Picchi, P; Pietropaolo, F; Rubbia, C; Sergiampietri, F; Ventura, S

    2011-01-01

    We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liquid Argon at a temperature of 87K.

  17. High-temperature vitrification of Hanford residual-liquid waste in a continuous melter

    International Nuclear Information System (INIS)

    Barnes, S.M.

    1980-04-01

    Over 270 kg of high-temperature borosilicate glass have been produced in a series of three short-term tests in the High-Temperature Ceramic Melter vitrification system at PNL. The glass produced was formulated to vitrify simulated Hanford residual-liquid waste. The tests were designed to (1) demonstrate the feasibility of utilizing high-temperature, continuous-vitrification technology for the immobilization of the residual-liquid waste, (2) test the airlift draining technique utilized by the high-temperature melter, (3) compare glass produced in this process to residual-liquid glass produced under laboratory conditions, (4) investigate cesium volatility from the melter during waste processing, and (5) determine the maximum residual-liquid glass production rate in the high-temperature melter. The three tests with the residual-liquid composition confirmed the viability of the continuous-melting vitrification technique for the immobilization of this waste. The airlift draining technique was demonstrated in these tests and the glass produced from the melter was shown to be less porous than the laboratory-produced glass. The final glass produced from the second test was compared to a glass of the same composition produced under laboratory conditions. The comparative tests found the glasses to be indistinguishable, as the small differences in the test results fell within the precision range of the characterization testing equipment. The cesium volatility was examined in the final test. This examination showed that 0.44 wt % of the cesium (assumed to be cesium oxide) was volatilized, which translates to a volatilization rate of 115 mg/cm 2 -h

  18. A mid-infrared laser absorption sensor for carbon monoxide and temperature measurements

    Science.gov (United States)

    Vanderover, Jeremy

    A mid-infrared (mid-IR) absorption sensor based on quantum cascade laser (QCL) technology has been developed and demonstrated for high-temperature thermometry and carbon monoxide (CO) measurements in combustion environments. The sensor probes the high-intensity fundamental CO ro-vibrational band at 4.6 mum enabling sensitive measurement of CO and temperature at kHz acquisition rates. Because the sensor operates in the mid-IR CO fundamental band it is several orders of magnitude more sensitive than most of the previously developed CO combustion sensors which utilized absorption in the near-IR overtone bands and mature traditional telecommunications-based diode lasers. The sensor has been demonstrated and validated under operation in both scanned-wavelength absorption and wavelength-modulation spectroscopy (WMS) modes in room-temperature gas cell and high-temperature shock tube experiments with known and specified gas conditions. The sensor has also been demonstrated for CO and temperature measurements in an atmospheric premixed ethylene/air McKenna burner flat flame for a range of equivalence ratios (phi = 0.7-1.4). Demonstration of the sensor under scanned-wavelength direct absorption operation was performed in a room-temperature gas cell (297 K and 0.001-1 atm) allowing validation of the line strengths and line shapes predicted by the HITRAN 2004 spectroscopic database. Application of the sensor in scanned-wavelength mode, at 1-2 kHz acquisition bandwidths, to specified high-temperature shock-heated gases (950-3400 K, 1 atm) provided validation of the sensor for measurements under the high-temperature conditions found in combustion devices. The scanned-wavelength shock tube measurements yielded temperature determinations that deviated by only +/-1.2% (1-sigma deviation) with the reflected shock temperatures and CO mole fraction determinations that deviated by that specified CO mole fraction by only +/-1.5% (1-sigma deviation). These deviations are in fact smaller

  19. Temperature effects on the structure of liquid D-methanol through ...

    Indian Academy of Sciences (India)

    Here, the liquid consists of deuterated methanol and neutron data was collected on the high- diffractometer at Dhruva, BARC. The corrected data at elevated temperatures (BP (boiling point) and double the BP) show that there is a large change in the H-bonded structure of this liquid. The pre-peak or hump, known to be ...

  20. Topics in low-temperature Fermi liquid theory

    International Nuclear Information System (INIS)

    Hess, D.W.

    1987-01-01

    Several topics in quantum liquids are discussed including the elementary excitation spectrum of 3 He under pressure, spin-polarized 3 He, and an early attempt to formulate a Fermi liquid theory to describe the low-temperature thermodynamic and transport properties of the heavy-electron systems UPt 3 . The elementary excitation spectrum of ordinary liquid 3 He is calculated at several pressures using the polarization potential theory of Aldrich and Pines together with a simple model to describe the effect of multipair excitation. The effective interactions between quasi particles in fully spin-polarized 3 He are obtained from physical arguments and sum rules. The interactions between two down-spin impurities and that between an up and down spin are also deduced. The regime of small polarization is considered next. Using the phenomenological model of Bedell and Sanchez-Castro together with an ansatz form for the spin-flip interaction, a large increase in the singlet scattering rate as a function of polarization is obtained

  1. Quantitative Analysis of Piroxicam Using Temperature-Controlled Ionic Liquid Dispersive Liquid Phase Microextraction Followed By Stopped-Flow Injection Spectrofluorimetry

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Ganjali

    2013-07-01

    Full Text Available Background:Piroxicam (PXM belongs to the wide class of non-steroidal anti-inflammatory drugs (NSAIDs. PXM has been widely applied in the treatment of rheumatoid arthritis, gonarthrosis, osteoarthritis, backaches, neuralgia, mialgia. In the presented work, a green and benign sample pretreatment method called temperature-controlled ionic liquid dispersive liquid phase microextraction (TCIL-DLPME was followed with stopped-flow injection spectrofluorimetry (SFIS for quantitation of PXM in pharmaceutical formulations and biological samples.Methods:Temperature-controlled ionic liquid dispersive liquid phase microextraction (TCIL-DLPME was applied as an environmentally friendly sample enrichment method to extract and isolate PXM prior to quantitation. Dispersion of 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF6] ionic liquid (IL through the sample aqueous solution was performed by applying a relatively high temperature. PXM was extracted into the extractor, and after phase separation, PXM in the final solution was determined by stopped-flow injection spectrofluorimetry (SFIS.Results and Major Conclusion:Different factors affecting the designed method such as IL amount, diluting agent, pH and temperature were investigated in details and optimized. The method provided a linear dynamic range of 0.2-150 μg l-1, a limit of detection (LOD of 0.046 μg l-1 and a relative standard deviation (RSD of 3.1%. Furthermore, in order to demonstrate the analytical applicability of the recommended method, it was applied for quantitation of PXM in real samples.

  2. Lithium bromide high-temperature absorption heat pump: coefficient of performance and exergetic efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo, M [Consejo Superior de Investigaciones Cientificas, Madrid (ES). Inst. de Optica; Aroca, S [Escuela Tecnica Superior de Ingenieros Industriales, Valladolid (ES). Catedratico de Ingenieria Termica

    1990-04-01

    A theoretical study of a lithium bromide absorption heat pump, used as a machine type I and aimed to produce heat at 120{sup 0}C via waste heat sources at 60{sup 0}C, is given. Real performance conditions are stated for each component of the machine. By means of thermodynamic diagrams (p, t, x) and (h, x), the required data are obtained for calculation of the heat recovered in the evaporator Q{sub e}, the heat delivered to the absorber Q{sub a} and to the condenser Q{sub c}, and the heat supplied to the generator Q{sub g}. The heat delivered by the hot solution to the cold solution in the heat recovered Q{sub r}, and the work W{sub p} done by the solution pump are calculated. The probable COP is calculated as close to 1.4 and the working temperature in the generator ranges from 178 to 200{sup 0}C. The heat produced by the heat pump is 22% cheaper than that obtained from a cogeneration system comprising a natural gas internal combustion engine and high temperature heat pump with mechanical compression. Compared with a high temperature heat pump with mechanical compression, the heat produced by the absorption heat pump is 31% cheaper. From (h, x) and (s, x) diagrams, exergy losses for each component can be determined leading to an exergetic efficiency of 75% which provides the quality index of the absorption cycle. (author).

  3. Electron mobility in nonpolar liquids: the effect of molecular structure, temperature and electric field

    International Nuclear Information System (INIS)

    Schmidt, W.F.

    1977-01-01

    A survey is given on the mobility of excess electrons in liquid hydrocarbons and related compounds. It was found that the mobility is strongly influenced by the molecular structure of the liquid, by the temperature, and by the electric field strength. The mobility in hydrocarbons increases as the shape of the molecule approaches a sphere. The temperature coefficient is positive in most liquids over a limited temperature although exceptions have been observed in liquid methane. The field dependence of the mobility in high mobility liquids (>10 cm 2 V -1 s -1 ) showed a decrease of the mobility at higher field strengths while in low mobility liquids ( 2 V -1 s -1 ) it showed an increase. These results are discussed on the basis of the extended and the localized electron models. The predictions of these theories are compared with the experimental results and conclusions on the validity of the underlying assumptions are drawn. (author)

  4. Theoretical analysis and experimental study on breakaway torque of large-diameter magnetic liquid seal at low temperature

    Science.gov (United States)

    Zhang, Haina; Li, Decai; Wang, Qinglei; Zhang, Zhili

    2013-07-01

    The existing researches of the magnetic liquid rotation seal have been mainly oriented to the seal at normal temperature and the seal with the smaller shaft diameter less than 100 mm. However, the large-diameter magnetic liquid rotation seal at low temperature has not been reported both in theory and in application up to now. A key factor restricting the application of the large-diameter magnetic liquid rotation seal at low temperature is the high breakaway torque. In this paper, the factors that influence the breakaway torque including the number of seal stages, the injected quantity of magnetic liquid and the standing time at normal temperature are studied. Two kinds of magnetic liquid with variable content of large particles are prepared first, and a seal feedthrough with 140 mm shaft diameter is used in the experiments. All experiments are carried out in a low temperature chamber with a temperature range from 200°C to -100°C. Different numbers of seal stages are tested under the same condition to study the relation between the breakaway torque and the number of seal stages. Variable quantity of magnetic liquid is injected in the seal gap to get the relation curve of the breakaway torque and the injecting quantity of magnetic liquid. In the experiment for studying the relation between the breakaway torque and the standing time at the normal temperature, the seal feedtrough is laid at normal temperature for different period of time before it is put in the low temperature chamber. The experimental results show that the breakaway torque is proportional to the number of seal stages, the injected quantity of magnetic liquid and the standing time at the normal temperature. Meanwhile, the experimental results are analyzed and the torque formula of magnetic liquid rotation seal at low temperature is deduced from the Navier-Stokes equation on the base of the model of magnetic liquid rotation seal. The presented research can make wider application of the magnetic liquid

  5. Molecular Dynamics Investigation of Efficient SO₂ Absorption by ...

    Indian Academy of Sciences (India)

    Ionic liquids are appropriate candidates for the absorption of acid gases such as SO₂. Six anion functionalized ionic liquids with different basicities have been studied for SO₂ absorption capacity by employing quantum chemical calculations and molecular dynamics (MD) simulations. Gas phase quantum calculations ...

  6. Phase separation temperatures of a liquid mixture: Dynamic light scattering technique

    International Nuclear Information System (INIS)

    Dangudom, K.; Wongtawatnugool, C.; Lacharojana, S.

    2010-01-01

    Light scattering intensity measurements and photon correlation spectroscopy (PCS) techniques were employed in an investigation of liquid-liquid phase separation behaviour of a mixture of cyclohexane and methanol at seven different compositions. It was found that, except for one composition (29% methanol), the temperature at which the scattering intensity was a maximum did not coincide with the one where the diffusion coefficient was a minimum, as would be for the case of a vapour-liquid system. The difference may be explained in terms of the local density fluctuation and the random walk problem responsible for the peak intensity and the minimum in the diffusion coefficient, respectively. The definition of phase separation temperature, as determined from diffusion process, was also proposed in this work.

  7. Thermal diffusivity measurements of liquid materials at high temperature with the ''laser flash'' method

    International Nuclear Information System (INIS)

    Otter, Claude; Vandevelde, Jean

    1982-01-01

    Two solutions, one analytical and the other numerical are proposed to solve the thermokinetic problem encountered when measuring the thermal diffusivity of liquid materials at very high temperature (T>3123K). The liquid material is contained in a parallel faced vessel. This liquid is traversed by a short thermal pulse from a relaxed laser. The temperature response of the back face of the measurement cell is analysed. The first model proposed which does not take thermal losses into consideration, is a mathematical model derived from the ''two layer model'' (Larson and Koyama, 1968) extended to ''three layers''. In order to take the possibility of thermal losses to the external environment at high temperature into consideration, a Crank-Nicolson (1947) type numerical model utilizing finite differences is employed. These thermokinetic studies were performed in order to interpret temperature response curves obtained from the back face of a tungsten-liquid UO 2 -tungsten thermal wall, the purpose of the measurements made being to determine the thermal properties of liquid uranium oxide [fr

  8. Analytical solution and numerical simulation of the liquid nitrogen freezing-temperature field of a single pipe

    Science.gov (United States)

    Cai, Haibing; Xu, Liuxun; Yang, Yugui; Li, Longqi

    2018-05-01

    Artificial liquid nitrogen freezing technology is widely used in urban underground engineering due to its technical advantages, such as simple freezing system, high freezing speed, low freezing temperature, high strength of frozen soil, and absence of pollution. However, technical difficulties such as undefined range of liquid nitrogen freezing and thickness of frozen wall gradually emerge during the application process. Thus, the analytical solution of the freezing-temperature field of a single pipe is established considering the freezing temperature of soil and the constant temperature of freezing pipe wall. This solution is then applied in a liquid nitrogen freezing project. Calculation results show that the radius of freezing front of liquid nitrogen is proportional to the square root of freezing time. The radius of the freezing front also decreases with decreased the freezing temperature, and the temperature gradient of soil decreases with increased distance from the freezing pipe. The radius of cooling zone in the unfrozen area is approximately four times the radius of the freezing front. Meanwhile, the numerical simulation of the liquid nitrogen freezing-temperature field of a single pipe is conducted using the Abaqus finite-element program. Results show that the numerical simulation of soil temperature distribution law well agrees with the analytical solution, further verifies the reliability of the established analytical solution of the liquid nitrogen freezing-temperature field of a single pipe.

  9. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  10. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    2001-01-01

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  11. Absorption cross-section measurements of methane, ethane, ethylene and methanol at high temperatures

    KAUST Repository

    Alrefae, Majed; Es-sebbar, Et-touhami; Farooq, Aamir

    2014-01-01

    Mid-IR absorption cross-sections are measured for methane, ethane, ethylene and methanol over 2800-3400 cm-1 (2.9-3.6 μm) spectral region. Measurements are carried out using a Fourier-Transform-Infrared (FTIR) spectrometer with temperatures ranging

  12. In-situ high-temperature Raman spectroscopic studies of aluminosilicate liquids

    Science.gov (United States)

    Daniel, Isabelle; Gillet, Philippe; Poe, Brent T.; McMillan, Paul F.

    1995-03-01

    We have measured in-situ Raman spectra of aluminosilicate glasses and liquids with albite (NaAlSi3 O8) and anorthite (CaAl2Si2O8) compositions at high temperatures, through their glass transition range up to 1700 and 2000 K, respectively. For these experiments, we have used a wire-loop heating device coupled with micro-Raman spectroscopy, in order to achieve effective spatial filtering of the extraneous thermal radiation. A major concern in this work is the development of methodology for reliably extracting the first and second order contributions to the Raman scattering spectra of aluminosilicate glasses and liquids from the high temperature experimental data, and analyzing these in terms of vibrational (anharmonic) and configurational changes. The changes in the first order Raman spectra with temperature are subtle. The principal low frequency band remains nearly constant with increasing temperature, indicating little change in the T-O-T angle, and that the angle bending vibration is quite harmonic. This is in contrast to vitreous SiO2, studied previously. Above Tg, intensity changes in the 560 590 cm-1 regions of both sets of spectra indicate configurational changes in the supercooled liquids, associated with formation of additional Al-O-Al linkages, or 3-membered (Al, Si)-containing rings. Additional intensity at 800 cm-1 reflects also some rearrangement of the Si-O-Al network.

  13. Microwave absorption properties of flake-shaped Co particles composites at elevated temperature (293-673 K) in X band

    Science.gov (United States)

    Wang, Guowu; Li, Xiling; Wang, Peng; Zhang, Junming; Wang, Dian; Qiao, Liang; Wang, Tao; Li, Fashen

    2018-06-01

    The complex permeability and permittivity of the easy-plane anisotropic Co/polyimide composite at high temperature (293-673 K) in X band were measured. The results show that both the complex permeability and permittivity increase with the increase of temperature in the measured temperature range. The calculated absorption properties display that the intensity of the reflection loss (RL) peak first increases and then decreases with the increase of temperature, and reaches the maximum (-52 dB) at 523 K. At each temperature, the composite can achieve the RL exceeding -10 dB in the whole X band. The composite can even work stably for more than 20 min with the excellent absorption performance under 673 K. In addition, the RL performance of the composite at high temperature is better than that at room temperature.

  14. Spatially resolved remote measurement of temperature by neutron resonance absorption

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [Space Sciences Laboratory, University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Kockelmann, W.; Pooley, D.E. [STFC, Rutherford Appleton Laboratory, ISIS Facility, Didcot OX11 0QX (United Kingdom); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Road, Sturbridge, MA 01566 (United States)

    2015-12-11

    Deep penetration of neutrons into most engineering materials enables non-destructive studies of their bulk properties. The existence of sharp resonances in neutron absorption spectra enables isotopically-resolved imaging of elements present in a sample, as demonstrated by previous studies. At the same time the Doppler broadening of resonance peaks provides a method of remote measurement of temperature distributions within the same sample. This technique can be implemented at a pulsed neutron source with a short initial pulse allowing for the measurement of the energy of each registered neutron by the time of flight technique. A neutron counting detector with relatively high timing and spatial resolution is used to demonstrate the possibility to obtain temperature distributions across a 100 µm Ta foil with ~millimeter spatial resolution. Moreover, a neutron transmission measurement over a wide energy range can provide spatially resolved sample information such as temperature, elemental composition and microstructure properties simultaneously.

  15. Temperature profiles in a steam-liquid sodium jet. Application to wastage

    International Nuclear Information System (INIS)

    Park, K.H.

    1983-12-01

    The first part of this work presents a certain number of recalls concerning wastage, jets, sonic jets, turbulent jets reactive or not. The aim of this thesis is to group the theoretical formulas concerning gaseous jets in liquids, to determine from experiments the temperature distributions inside the reactive jet, and to establish correlations between the theory and the experiments carried out to obtain a model representative of the temperature distribution in steam jets into liquid sodium. The theoretical development is presented (differential and integral approaches), as also the experiments (JONAS) developed to determine the temperature distribution. The field of validity of experiments and approximations is then defined in view of application to wastage [fr

  16. Heat of Absorption of CO2 in Aqueous Solutions of DEEA, MAPA and their Mixture

    DEFF Research Database (Denmark)

    Waseem Arshad, Muhammad; von Solms, Nicolas; Thomsen, Kaj

    2013-01-01

    A reaction calorimeter was used to measure the differential heat of absorption of CO2 in phase change solvents as a function of temperature, CO2 loading and solvent composition. The measurements were taken for aqueous solutions of 2-(diethylamino)ethanol (DEEA), 3-(methylamino)propylamine (MAPA......) and their mixture. The tested compositions were 5M DEEA, 2M MAPA and their mixture, 5M DEEA + 2M MAPA which gives two liquid phases on reacting with CO2. Experimental measurements were also carried out for 30% MEA used as a base case. The measurements were taken isothermally at three different temperatures 40, 80...... and 120°C at a CO2 feed pressure of 600kPa. In single aqueous amine solutions, heat of absorption increases with increase in temperature and depends on thetype of amine used. DEEA, a tertiary amine, has lower heat of absorption compared to MAPA being a diamine with primary and secondary amine functional...

  17. Temperature-Induced Large Broadening and Blue Shift in the Electronic Band Structure and Optical Absorption of Methylammonium Lead Iodide Perovskite.

    Science.gov (United States)

    Yang, Jia-Yue; Hu, Ming

    2017-08-17

    The power conversion efficiency of hybrid halide perovskite solar cells is profoundly influenced by the operating temperature. Here we investigate the temperature influence on the electronic band structure and optical absorption of cubic CH 3 NH 3 PbI 3 from first-principles by accounting for both the electron-phonon interaction and thermal expansion. Within the framework of density functional perturbation theory, the electron-phonon coupling induces slightly enlarged band gap and strongly broadened electronic relaxation time as temperature increases. The large broadening effect is mainly due to the presence of cation organic atoms. Consequently, the temperature-dependent absorption peak exhibits blue-shift position, decreased amplitude, and broadened width. This work uncovers the atomistic origin of temperature influence on the optical absorption of cubic CH 3 NH 3 PbI 3 and can provide guidance to design high-performance hybrid halide perovskite solar cells at different operating temperatures.

  18. Absolute and convective instability of a liquid sheet with transverse temperature gradient

    International Nuclear Information System (INIS)

    Fu, Qing-Fei; Yang, Li-Jun; Tong, Ming-Xi; Wang, Chen

    2013-01-01

    Highlights: • The spatial–temporal instability of a liquid sheet with thermal effects was studied. • The flow can transit to absolutely unstable with certain flow parameters. • The effects of non-dimensional parameters on the transition were studied. -- Abstract: The spatial–temporal instability behavior of a viscous liquid sheet with temperature difference between the two surfaces was investigated theoretically. The practical situation motivating this investigation is liquid sheet heated by ambient gas, usually encountered in industrial heat transfer and liquid propellant rocket engines. The existing dispersion relation was used, to explore the spatial–temporal instability of viscous liquid sheets with a nonuniform temperature profile, by setting both the wave number and frequency complex. A parametric study was performed in both sinuous and varicose modes to test the influence of dimensionless numbers on the transition between absolute and convective instability of the flow. For a small value of liquid Weber number, or a great value of gas-to-liquid density ratio, the flow was found to be absolutely unstable. The absolute instability was enhanced by increasing the liquid viscosity. It was found that variation of the Marangoni number hardly influenced the absolute instability of the sinuous mode of oscillations; however it slightly affected the absolute instability in the varicose mode

  19. Force-detected nanoscale absorption spectroscopy in water at room temperature using an optical trap

    Science.gov (United States)

    Parobek, Alexander; Black, Jacob W.; Kamenetska, Maria; Ganim, Ziad

    2018-04-01

    Measuring absorption spectra of single molecules presents a fundamental challenge for standard transmission-based instruments because of the inherently low signal relative to the large background of the excitation source. Here we demonstrate a new approach for performing absorption spectroscopy in solution using a force measurement to read out optical excitation at the nanoscale. The photoinduced force between model chromophores and an optically trapped gold nanoshell has been measured in water at room temperature. This photoinduced force is characterized as a function of wavelength to yield the force spectrum, which is shown to be correlated to the absorption spectrum for four model systems. The instrument constructed for these measurements combines an optical tweezer with frequency domain absorption spectroscopy over the 400-800 nm range. These measurements provide proof-of-principle experiments for force-detected nanoscale spectroscopies that operate under ambient chemical conditions.

  20. Desulfurization performance of azole-based ionic liquids

    Directory of Open Access Journals (Sweden)

    Liubei CHENG

    2017-10-01

    Full Text Available In order to study the addition of functional groups in ionic liquid anion and cation to achieve better absorbing of SO2, the 1,1,3,3-tetramethylguanidine triazole ( is synthesized using 1,1,3,3-tetramethylguanidine and triazole as raw materials. The desulfurization performance of the synthesized is systematically studied. The desulfurization performance and desulfurization mechanism of the are discussed. The results show that the has good performance of desulfurization and regeneration. At the atmospheric pressure, 1 mol of the absorbs 2.964 mol of SO2 at 20 ℃. With the increase of temperature, the desulfurization capacity of the decreases gradually. The molar absorption ratio increases with the increase of SO2 partial pressure, and under the conditions of 130 ℃, the desorption rate of the ionic liquid after saturated adsorption reaches over 95%. The mechanism investigation results show that the interaction of SO2 and is the combination of chemical absorption and physical absorption. The results have a certain reference value to improve the efficiency of flue gas treatment.

  1. Extraction and preconcentration of trace Al and Cr from vegetable samples by vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction prior to atomic absorption spectrometric determination.

    Science.gov (United States)

    Altunay, Nail; Yıldırım, Emre; Gürkan, Ramazan

    2018-04-15

    In the study, a simple, and efficient microextraction approach, which is termed as vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction (VA-IL-DLLME), was developed for flame atomic absorption spectrometric analysis of aluminum (Al) and chromium (Cr) in vegetables. The method is based on the formation of anionic chelate complexes of Al(III) and Cr(VI) with o-hydroxy azo dye, at pH 6.5, and then extraction of the hydrophobic ternary complexes formed in presence of cetyltrimethylammonium bromide (CTAB) into a 125 μL volume of 1-butyl-3-methylimidazolium bis(trifluorosulfonyl)imide [C 4 mim][Tf 2 N]) as extraction solvent. Under optimum conditions, the detection limits were 0.02 µg L -1 in linear working range of 0.07-100 µg L -1 for Al(III), and 0.05 µg L -1 in linear working range of 0.2-80 µg L -1 for Cr(VI). After the validation by analysis of a certified reference material (CRM), the method was successfully applied to the determination of Al and Cr in vegetables using standard addition method. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Gas Transport Properties of PEBAX®/Room Temperature Ionic Liquid Gel Membranes

    Czech Academy of Sciences Publication Activity Database

    Bernardo, P.; Jansen, J. C.; Bazzarelli, F.; Tasselli, F.; Fuoco, A.; Friess, K.; Izák, Pavel; Jarmarová, Veronika; Kačírková, Marie; Clarizia, G.

    2012-01-01

    Roč. 97, SI (2012), s. 73-82 ISSN 1383-5866. [Conference on Ionic Liquids in Separation and Purification Technology (ILSEPT) /1./. Sitges, 04.09.2011-07.09.2011] R&D Projects: GA ČR GAP106/10/1194 Grant - others:RFCS(XE) RFCR-CT-2010-00009 Institutional support: RVO:67985858 Keywords : room temperature ionic liquid * ionic liquid * polymer gel Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.894, year: 2012

  3. Liquid Photonic Crystals for Mesopore Detection.

    Science.gov (United States)

    Zhu, Biting; Fu, Qianqian; Chen, Ke; Ge, Jianping

    2018-01-02

    Nitrogen adsorption-desorption for mesopore characterization requires the using of expensive instrumentation, time-consuming processes, and the consumption of liquid nitrogen. Herein, a new method is developed to measure the pore parameters through mixing a mesoporous substance with a supersaturated SiO 2 colloidal solution at different temperatures, and subsequent rapid measurement of reflection changes of the precipitated liquid photonic crystals. The pore volumes and diameters of mesoporous silica were measured according to the positive correlation between unit mass reflection change (Δλ/m) and pore volume (V), and the negative correlation between average absorption temperature (T) and pore diameter (D). This new approach may provide an alternative method for fast, convenient and economical characterization of mesoporous materials. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Influence of temperature to quenching on liquid scintillation measurement

    CERN Document Server

    Kato, T

    2003-01-01

    The amount of quench is measured with liquid scintillation spectrometer changing the temperature of the sample. The range of the changed temperature is between 0 deg C and 35 deg C. The measurement is carried out for three kinds of unquenched standard, two quenched standards and fifteen kinds of scintillation cocktail and the mixed sample. It is confirmed that the amount of quench increases for all samples as the temperature rises. The influence of the changed amount of quench to the quench correction is examined. (author)

  5. Search for the first-order liquid-to-liquid phase transition in low-temperature confined water by neutron scattering

    Science.gov (United States)

    Chen, Sow-Hsin; Wang, Zhe; Kolesnikov, Alexander I.; Zhang, Yang; Liu, Kao-Hsiang

    2013-02-01

    It has been conjectured that a 1st order liquid-to-liquid (L-L) phase transition (LLPT) between high density liquid (HDL) and low density liquid (LDL) in supercooled water may exist, as a thermodynamic extension to the liquid phase of the 1st order transition established between the two bulk solid phases of amorphous ice, the high density amorphous ice (HDA) and the low density amorphous ice (LDA). In this paper, we first recall our previous attempts to establish the existence of the 1st order L-L phase transition through the use of two neutron scattering techniques: a constant Q elastic diffraction study of isobaric temperature scan of the D2O density, namely, the equation of state (EOS) measurements. A pronounced density hysteresis phenomenon in the temperature scan of the density above P = 1500 bar is observed which gives a plausible evidence of crossing the 1st order L-L phase transition line above this pressure; an incoherent quasi-elastic scattering measurements of temperature-dependence of the α-relaxation time of H2O at a series of pressures, namely, the study of the Fragile-to-Strong dynamic crossover (FSC) phenomenon as a function of pressure which we interpreted as the results of crossing the Widom line in the one-phase region. In this new experiment, we used incoherent inelastic neutron scattering (INS) to measure the density of states (DOS) of H atoms in H2O molecules in confined water as function of temperature and pressure, through which we may be able to follow the emergence of the LDL and HDL phases at supercooled temperature and high pressures. We here report for the first time the differences of librational and translational DOSs between the hypothetical HDL and LDL phases, which are similar to the corresponding differences between the well-established HDA and LDA ices. This is plausible evidence that the HDL and LDL phases are the thermodynamic extensions of the corresponding amorphous solid water HDA and LDA ices.

  6. The physics and chemistry of room-temperature liquid-filled ionization chambers

    International Nuclear Information System (INIS)

    Holroyd, R.A.

    1985-01-01

    The properties of excess electrons in non-polar liquids, such as tetramethylsilane and 2,2,4,4-tetramethylpentane, which are suitable for room-temperature liquid-filled ionization chambers are reviewed. Such properties as mobility, ionization yield, conduction band energy, trapping, and the influence of the electric field are considered. (orig.)

  7. Liquid level measurement on coolant pipeline using Raman distributed temperature sensor

    International Nuclear Information System (INIS)

    Kasinathan, M.; Sosamma, S.; Babu Rao, C.; Murali, N.; Jayakumar, T.

    2011-01-01

    Optical fibre based Raman Distributed Temperature Sensor (RDTS) has been widely used for temperature monitoring in oil pipe line, power cable and environmental monitoring. Recently it has gained importance in nuclear reactor owing to its advantages like continuous, distributed temperature monitoring and immunity from electromagnetic interference. It is important to monitor temperature based level measurement in sodium capacities and in coolant pipelines for Fast Breeder Reactor (FBR). This particular application is used for filling and draining sodium in storage tank of sodium circuits of Fast breeder reactor. There are different conventional methods to find out the sodium level in the storage tank of sodium cooled reactors. They are continuous level measurement and discontinuous level measurement. For continuous level measurement, mutual inductance type level probes are used. The disadvantage of using this method is it needs a temperature compensation circuit. For discontinuous level measurement, resistance type discontinuous level probe and mutual inductance type discontinuous level probe are used. In resistance type discontinuous level probe, each level needs a separate probe. To overcome these disadvantages, RDTS is used for level measurement based distributed temperature from optical fibre as sensor. The feasibility of using RDTS for measurement of temperature based level measurement sensor is studied using a specially designed test set-up and using hot water, instead of sodium. The test set-up consist of vertically erected Stainless Steel (SS) pipe of length 2m and diameter 10cm, with provision for filling and draining out the liquid. Bare graded index multimode fibre is laid straight along the length of the of the SS pipe. The SS pipe is filled with hot water at various levels. The hot water in the SS pipe is maintained at constant temperature by insulating the SS pipe. The temperature profile of the hot water at various levels is measured using RDTS. The

  8. Profile modification and hot electron temperature from resonant absorption at modest intensity

    International Nuclear Information System (INIS)

    Albritton, J.R.; Langdon, A.B.

    1980-01-01

    Resonant absorption is investigated in expanding plasmas. The momentum deposition associated with the ejection of hot electrons toward low density via wavebreaking readily exceeds that of the incident laser radiation and results in significant modification of the density profile at critical. New scaling of hot electron temperature with laser and plasma parameters is presented

  9. Electrokinetic detection for X-ray spectra of weakly interacting liquids: n-decane and n-nonane

    Science.gov (United States)

    Lam, Royce K.; Shih, Orion; Smith, Jacob W.; Sheardy, Alex T.; Rizzuto, Anthony M.; Prendergast, David; Saykally, Richard J.

    2014-06-01

    The introduction of liquid microjets into soft X-ray absorption spectroscopy enabled the windowless study of liquids by this powerful atom-selective high vacuum methodology. However, weakly interacting liquids produce large vapor backgrounds that strongly perturb the liquid signal. Consequently, solvents (e.g., hydrocarbons, ethers, ketones, etc.) and solutions of central importance in chemistry and biology have been inaccessible by this technology. Here we describe a new detection method, upstream detection, which greatly reduces the vapor phase contribution to the X-ray absorption signal while retaining important advantages of liquid microjet sample introduction (e.g., minimal radiation damage). The effectiveness of the upstream detection method is demonstrated in this first study of room temperature liquid hydrocarbons: n-nonane and n-decane. Good agreement with first principles' calculations indicates that the eXcited electron and Core Hole theory adequately describes the subtle interactions in these liquids that perturb the electronic structure of the unoccupied states probed in core-level experiments.

  10. Electrokinetic detection for X-ray spectra of weakly interacting liquids: n-decane and n-nonane

    International Nuclear Information System (INIS)

    Lam, Royce K.; Smith, Jacob W.; Sheardy, Alex T.; Rizzuto, Anthony M.; Saykally, Richard J.; Shih, Orion; Prendergast, David

    2014-01-01

    The introduction of liquid microjets into soft X-ray absorption spectroscopy enabled the windowless study of liquids by this powerful atom-selective high vacuum methodology. However, weakly interacting liquids produce large vapor backgrounds that strongly perturb the liquid signal. Consequently, solvents (e.g., hydrocarbons, ethers, ketones, etc.) and solutions of central importance in chemistry and biology have been inaccessible by this technology. Here we describe a new detection method, upstream detection, which greatly reduces the vapor phase contribution to the X-ray absorption signal while retaining important advantages of liquid microjet sample introduction (e.g., minimal radiation damage). The effectiveness of the upstream detection method is demonstrated in this first study of room temperature liquid hydrocarbons: n-nonane and n-decane. Good agreement with first principles’ calculations indicates that the eXcited electron and Core Hole theory adequately describes the subtle interactions in these liquids that perturb the electronic structure of the unoccupied states probed in core-level experiments

  11. Electrokinetic detection for X-ray spectra of weakly interacting liquids: n-decane and n-nonane

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Royce K.; Smith, Jacob W.; Sheardy, Alex T.; Rizzuto, Anthony M.; Saykally, Richard J., E-mail: saykally@berkeley.edu [Department of Chemistry, University of California, Berkeley, California 94720 (United States); Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Shih, Orion [Department of Chemistry, University of California, Berkeley, California 94720 (United States); Prendergast, David [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2014-06-21

    The introduction of liquid microjets into soft X-ray absorption spectroscopy enabled the windowless study of liquids by this powerful atom-selective high vacuum methodology. However, weakly interacting liquids produce large vapor backgrounds that strongly perturb the liquid signal. Consequently, solvents (e.g., hydrocarbons, ethers, ketones, etc.) and solutions of central importance in chemistry and biology have been inaccessible by this technology. Here we describe a new detection method, upstream detection, which greatly reduces the vapor phase contribution to the X-ray absorption signal while retaining important advantages of liquid microjet sample introduction (e.g., minimal radiation damage). The effectiveness of the upstream detection method is demonstrated in this first study of room temperature liquid hydrocarbons: n-nonane and n-decane. Good agreement with first principles’ calculations indicates that the eXcited electron and Core Hole theory adequately describes the subtle interactions in these liquids that perturb the electronic structure of the unoccupied states probed in core-level experiments.

  12. Effect of temperature on the (liquid + liquid) equilibrium for aqueous solution of nonionic surfactant and salt: Experimental and modeling

    Energy Technology Data Exchange (ETDEWEB)

    Foroutan, Masumeh [Physical Chemistry Department, School of Chemistry, College of Science, University of Tehran, 14155-6455 Enghelab Avenue, Tehran (Iran, Islamic Republic of)], E-mail: foroutan@khayam.ut.ac.ir; Heidari, Nosrat; Mohammadlou, Maryam [Chemistry Department, Faculty of Science, Uremia University, Uremia (Iran, Islamic Republic of); Sojahrood, Amin Jafari [Physics Department, Faculty of Science, Uremia University, Uremia (Iran, Islamic Republic of)

    2008-07-15

    The effect of temperature on the (liquid + liquid) equilibrium of the aqueous solution of surfactant polyoxyethylene cetylether (with abbreviation name Brij 58) and diammonium hydrogen phosphate has been investigated at T = (303.15, 313.15, 323.15, and 333.15) K. The Flory-Huggins equation with two electrostatic terms (Debye-Huckle and Pitzer-Debye-Huckle equations) was used to correlate the phase behavior of this system. Good agreement has been found between experimental and calculated data from both models. The results indicated that the enlargement of the two-phase region upon increasing the temperature. Additionally temperature dependency of the parameters of the Flory-Huggins model has been calculated.

  13. Tuning the shell thickness-dependent plasmonic absorption of Ag coated Au nanocubes: The effect of synthesis temperature

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jian, E-mail: jianzhusummer@163.com; Zhang, Fan; Chen, Bei-Bei; Li, Jian-Jun; Zhao, Jun-Wu, E-mail: nanoptzhao@163.com

    2015-09-15

    Graphical abstract: Ag coating leads to great enhancement of SPR absorbance of Au nanocubes, and the Ag coating-dependent non-monotonous SPR shift is greater at lower temperature. - Highlights: • Au nanocubes with more uniform shape can be obtained at lower growth temperature. • Ag coating leads to great enhancement of SPR absorption intensity. • The Ag coating dependent non-monotonous SPR shift is greater at lower temperature. - Abstract: The temperature dependent synthesis and plasmonic optical properties of Ag coated Au nanocubes have been investigated experimentally. It has been found that the Au nanocubes with more uniform morphology and higher yield could be obtained by decreasing the growth temperature. Because of the non-spherical symmetry of the particles shape and the plasmon coupling between Au–Ag interface and outer Ag surface, four absorption peaks at most have been observed. As the Ag coating thickness is increased, the absorbance intensity of these plasmon peaks gets intense greatly, and the absorption peak at longest wavelength blue shifts firstly and then red shifts. The non-monotonous plasmonic shift has been attributed to the competition between the increase of Ag composition and the enlargement of the particle size. What's more, the wavelength region of both blue shift and red shift could also be enhanced by decreasing the temperature.

  14. Tuning the shell thickness-dependent plasmonic absorption of Ag coated Au nanocubes: The effect of synthesis temperature

    International Nuclear Information System (INIS)

    Zhu, Jian; Zhang, Fan; Chen, Bei-Bei; Li, Jian-Jun; Zhao, Jun-Wu

    2015-01-01

    Graphical abstract: Ag coating leads to great enhancement of SPR absorbance of Au nanocubes, and the Ag coating-dependent non-monotonous SPR shift is greater at lower temperature. - Highlights: • Au nanocubes with more uniform shape can be obtained at lower growth temperature. • Ag coating leads to great enhancement of SPR absorption intensity. • The Ag coating dependent non-monotonous SPR shift is greater at lower temperature. - Abstract: The temperature dependent synthesis and plasmonic optical properties of Ag coated Au nanocubes have been investigated experimentally. It has been found that the Au nanocubes with more uniform morphology and higher yield could be obtained by decreasing the growth temperature. Because of the non-spherical symmetry of the particles shape and the plasmon coupling between Au–Ag interface and outer Ag surface, four absorption peaks at most have been observed. As the Ag coating thickness is increased, the absorbance intensity of these plasmon peaks gets intense greatly, and the absorption peak at longest wavelength blue shifts firstly and then red shifts. The non-monotonous plasmonic shift has been attributed to the competition between the increase of Ag composition and the enlargement of the particle size. What's more, the wavelength region of both blue shift and red shift could also be enhanced by decreasing the temperature

  15. Optimum filters with time width constraints for liquid argon total-absorption detectors

    International Nuclear Information System (INIS)

    Gatti, E.; Radeka, V.

    1977-10-01

    Optimum filter responses are found for triangular current input pulses occurring in liquid argon ionization chambers used as total absorption detectors. The filters considered are subject to the following constraints: finite width of the output pulse having a prescribed ratio to the width of the triangular input current pulse and zero area of a bipolar antisymmetrical pulse or of a three lobe pulse, as required for high event rates. The feasibility of pulse shaping giving an output equal to, or shorter than, the input one is demonstrated. It is shown that the signal-to-noise ratio remains constant for the chamber interelectrode gap which gives an input pulse width (i.e., electron drift time) greater than one third of the required output pulse width

  16. Acoustic levitator for containerless measurements on low temperature liquids

    Energy Technology Data Exchange (ETDEWEB)

    Benmore, Chris J [Argonne National Laboratory (ANL); Weber, Richard [Argonne National Laboratory (ANL); Neuefeind, Joerg C [ORNL; Rey, Charles A A [Charles Ray, Inc.

    2009-01-01

    A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops at temperatures from -40 to +40 C. The levitator consisted of: (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) a acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ~ 22 kHz and could produce sound pressure levels up to 160 dB. The force applied by the acoustic field could be modulated using a frequency generator to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

  17. High-temperature reactors for underground liquid-fuels production with direct carbon sequestration

    International Nuclear Information System (INIS)

    Forsberg, C. W.

    2008-01-01

    The world faces two major challenges: (1) reducing dependence on oil from unstable parts of the world and (2) minimizing greenhouse gas emissions. Oil provides 39% of the energy needs of the United States, and oil refineries consume over 7% of the total energy. The world is running out of light crude oil and is increasingly using heavier fossil feedstocks such as heavy oils, tar sands, oil shale, and coal for the production of liquid fuels (gasoline, diesel, and jet fuel). With heavier feedstocks, more energy is needed to convert the feedstocks into liquid fuels. In the extreme case of coal liquefaction, the energy consumed in the liquefaction process is almost twice the energy value of the liquid fuel. This trend implies large increases in carbon dioxide releases per liter of liquid transport fuel that is produced. It is proposed that high-temperature nuclear heat be used to refine hydrocarbon feedstocks (heavy oil, tar sands, oil shale, and coal) 'in situ ', i.e., underground. Using these resources for liquid fuel production would potentially enable the United States to become an exporter of oil while sequestering carbon from the refining process underground as carbon. This option has become potentially viable because of three technical developments: precision drilling, underground isolation of geological formations with freeze walls, and the understanding that the slow heating of heavy hydrocarbons (versus fast heating) increases the yield of light oils while producing a high-carbon solid residue. Required peak reactor temperatures are near 700 deg. C-temperatures within the current capabilities of high-temperature reactors. (authors)

  18. Temperature-triggered release of a liquid cross-linker micro-encapsulated in a glassy polymer for low temperature curing

    NARCIS (Netherlands)

    Senatore, D.; Cate, ten A.T.; Laven, J.; Benthem, van R.A.T.M.; With, de G.

    2013-01-01

    In order to prevent a liquid epoxy cross-linker from premature, Arrhenius-law predicted, reaction with an acid-functional polyester resin, the liquid cross-linker has been physically separated from the resin by encapsulation while release is only possible by a temperature-controlled trigger. The

  19. Nuclear quadrupole relaxation and viscosity in liquid metals

    International Nuclear Information System (INIS)

    Schirmacher, W.

    1976-01-01

    It is shown that the nuclear quadrupole relaxation rate due to the molecular motions in liquid metals is related to the shear and bulk viscosity and hence to the absorption coefficient of ultrasound. Application of the 'extended liquid phonon' model of Ortoleva and Nelkin - which is the third of a series of continued-fraction-approximations for the van Hove neutron scattering function - gives a relation to the self diffusion constant. The predictions of the theory concerning the temperature dependence are compared with quadrupole relaxation measurements of Riegel et al. and Kerlin et al. in liquid gallium. Agreement is found only with the data of Riegel et al. (orig.) [de

  20. Is the boundary layer of an ionic liquid equally lubricating at higher temperature?

    Science.gov (United States)

    Hjalmarsson, Nicklas; Atkin, Rob; Rutland, Mark W

    2016-04-07

    Atomic force microscopy has been used to study the effect of temperature on normal forces and friction for the room temperature ionic liquid (IL) ethylammonium nitrate (EAN), confined between mica and a silica colloid probe at 25 °C, 50 °C, and 80 °C. Force curves revealed a strong fluid dynamic influence at room temperature, which was greatly reduced at elevated temperatures due to the reduced liquid viscosity. A fluid dynamic analysis reveals that bulk viscosity is manifested at large separation but that EAN displays a nonzero slip, indicating a region of different viscosity near the surface. At high temperatures, the reduction in fluid dynamic force reveals step-like force curves, similar to those found at room temperature using much lower scan rates. The ionic liquid boundary layer remains adsorbed to the solid surface even at high temperature, which provides a mechanism for lubrication when fluid dynamic lubrication is strongly reduced. The friction data reveals a decrease in absolute friction force with increasing temperature, which is associated with increased thermal motion and reduced viscosity of the near surface layers but, consistent with the normal force data, boundary layer lubrication was unaffected. The implications for ILs as lubricants are discussed in terms of the behaviour of this well characterised system.

  1. Light absorption of organic aerosol from pyrolysis of corn stalk

    Science.gov (United States)

    Li, Xinghua; Chen, Yanju; Bond, Tami C.

    2016-11-01

    Organic aerosol (OA) can absorb solar radiation in the low-visible and ultra-violet wavelengths thereby modifying radiative forcing. Agricultural waste burning emits a large quantity of organic carbon in many developing countries. In this work, we improved the extraction and analysis method developed by Chen and Bond, and extended the spectral range of OC absorption. We examined light absorbing properties of primary OA from pyrolysis of corn stalk, which is a major type of agricultural wastes. Light absorption of bulk liquid extracts of OA was measured using a UV-vis recording spectrophotometer. OA can be extracted by methanol at 95%, close to full extent, and shows polar character. Light absorption of organic aerosol has strong spectral dependence (Absorption Ångström exponent = 7.7) and is not negligible at ultra-violet and low-visible regions. Higher pyrolysis temperature produced OA with higher absorption. Imaginary refractive index of organic aerosol (kOA) is 0.041 at 400 nm wavelength and 0.005 at 550 nm wavelength, respectively.

  2. One-step displacement dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of methylmercury in environmental samples.

    Science.gov (United States)

    Liang, Pei; Kang, Caiyan; Mo, Yajun

    2016-01-01

    A novel method for the selective determination of methylmercury (MeHg) was developed by one-step displacement dispersive liquid-liquid microextraction (D-DLLME) coupled with graphite furnace atomic absorption spectrometry. In the proposed method, Cu(II) reacted with diethyldithiocarbamate (DDTC) to form Cu-DDTC complex, which was used as the chelating agent instead of DDTC for the dispersive liquid-liquid microextraction (DLLME) of MeHg. Because the stability of MeHg-DDTC is higher than that of Cu-DDTC, MeHg can displace Cu from the Cu-DDTC complex and be preconcentrated in a single DLLME procedure. MeHg could be extracted into the extraction solvent phase at pH 6 while Hg(II) remained in the sample solution. Potential interference from co-existing metal ions with lower DDTC complex stability was largely eliminated without the need of any masking reagent. Under the optimal conditions, the limit of detection of this method was 13.6ngL(-1) (as Hg), and an enhancement factor of 81 was achieved with a sample volume of 5.0mL. The proposed method was successfully applied for the determination of trace MeHg in some environmental samples with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Correlation Between Superheated Liquid Fragility And Onset Temperature Of Crystallization For Al-Based Amorphous Alloys

    Directory of Open Access Journals (Sweden)

    Guo J.

    2015-06-01

    Full Text Available Amorphous alloys or metallic glasses have attracted significant interest in the materials science and engineering communities due to their unique physical, mechanical, and chemical properties. The viscous flow of amorphous alloys exhibiting high strain rate sensitivity and homogeneous deformation is considered to be an important characteristic in thermoplastic forming processes performed within the supercooled liquid region because it allows superplastic-like deformation behavior. Here, the correlation between the superheated liquid fragility, and the onset temperature of crystallization for Al-based alloys, is investigated. The activation energy for viscous flow of the liquid is also investigated. There is a negative correlation between the parameter of superheated liquid fragility and the onset temperature of crystallization in the same Al-based alloy system. The activation energy decreases as the onset temperature of crystallization increases. This indicates that the stability of a superheated liquid can affect the thermal stability of the amorphous alloy. It also means that a liquid with a large superheated liquid fragility, when rapidly solidified, forms an amorphous alloy with a low thermal stability.

  4. Method and apparatus for determination of temperature, neutron absorption cross section and neutron moderating power

    Science.gov (United States)

    Vagelatos, Nicholas; Steinman, Donald K.; John, Joseph; Young, Jack C.

    1981-01-01

    A nuclear method and apparatus determines the temperature of a medium by injecting fast neutrons into the medium and detecting returning slow neutrons in three first energy ranges by producing three respective detection signals. The detection signals are combined to produce three derived indicia each systematically related to the population of slow neutrons returning from the medium in a respective one of three second energy ranges, specifically exclusively epithermal neutrons, exclusively substantially all thermal neutrons and exclusively a portion of the thermal neutron spectrum. The derived indicia are compared with calibration indicia similarly systematically related to the population of slow neutrons in the same three second energy ranges returning from similarly irradiated calibration media for which the relationships temperature, neutron absorption cross section and neutron moderating power to such calibration indicia are known. The comparison indicates the temperature at which the calibration indicia correspond to the derived indicia and consequently the temperature of the medium. The neutron absorption cross section and moderating power of the medium can be identified at the same time.

  5. Dispersive liquid-liquid microextraction (DLLME combined with graphite furnace atomic absorption spectrometry (GFAAS for determination of trace Cu and Zn in water Samples

    Directory of Open Access Journals (Sweden)

    Ghorbani A.

    2014-07-01

    Full Text Available Dispersive liquid-liquid microextraction (DLLME combined with graphite furnace atomic absorption spectrometry (GFAAS was proposed for the determination of trace amounts of Copper and Zinc ions using 8-hydroxyquinoline (8-HQ as chelating agent. Several factors influencing the microextraction efficiency of Cu and Zn and their subsequent determinations, such as pH, extraction and disperser solvent type and their volume, concentration of the chelating agent and extraction time were studied, and the optimized experimental conditions were established. After extraction, the enrichment factors were 25 and 26 for Cu and Zn, respectively. The detection limits of the method were 0.025 and 0.0033 μg/L for Cu and Zn, and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Cu and Zn were 8.51% and 7.41%, respectively.

  6. Ionic Liquids: Breakthrough Absorption Technology for Post-Combustion CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Maginn, Edward

    2012-09-30

    This is the final report for DE-FC26-07NT43091 Ionic Liquids: Breakthrough Absorption Technology for Post-Combustion CO{sub 2} Capture. A detailed summary is provided of the ionic liquid (IL) discovery process, synthesis and testing results, process / systems modeling, lab-scale operational testing, corrosion testing and commercialization possibilities. The work resulted in the discovery of a new class of ionic liquids (ILs) that efficiently react with CO{sub 2} in a 1:1 stoichiometry with no water present and no increase in viscosity. The enthalpy of reaction was tuned to optimize process economics. The IL was found to have excellent corrosion behavior with and without CO{sub 2} present. In lab-scale tests, the IL was able to effectively remove CO{sub 2} from a simulated flue gas stream, although mass transfer was slower than with aqueous monoethanolamine (MEA) due to higher viscosities. The non-volatile nature of the solvent and its high thermal stability, however, make it an intriguing option. An independent systems analysis indicates that the economics of using the best IL discovered to date (NDIL0157), are at least comparable to and potentially slightly better than - the Fluor Econamine FG PlusTM process (DOE Case 12). Further work should be directed at improving mass transfer / lowering viscosity and developing commercial synthesis routes to make these ILs at scale in an inexpensive manner. Demonstration of the process at larger scales is also warranted, as is the exploration of other process configurations that leverage the anhydrous nature of the solvent and its extremely low volatility.

  7. Temperature dependence of transport coefficients of 'simple liquid ...

    African Journals Online (AJOL)

    ... has been investigated. The study carried out at two densities, r* = 0.60 and r* = 0.95. Result shows erratic variations of the shear viscosity in the two lattices structures. KeyWords: Temperature effect, face centred, simple cubic, transport properties, simple liquid. [Global Jnl Pure & Appl. Sci. Vol.9(3) 2003: 403-406] ...

  8. Density of Fe-3.5 wt% C liquid at high pressure and temperature and the effect of carbon on the density of the molten iron

    Science.gov (United States)

    Shimoyama, Yuta; Terasaki, Hidenori; Ohtani, Eiji; Urakawa, Satoru; Takubo, Yusaku; Nishida, Keisuke; Suzuki, Akio; Katayama, Yoshinori

    2013-11-01

    Carbon is a plausible light element candidate in the Earth’s outer core. We measured the density of liquid Fe-3.5 wt% C up to 6.8 GPa and 2200 K using an X-ray absorption method. The compression curve of liquid Fe-C was fitted using the third-order Birch-Murnaghan equation of state. The bulk modulus and its pressure derivative are K0,1500K = 55.3 ± 2.5 GPa and (dK0/dP)T = 5.2 ± 1.5, and the thermal expansion coefficient is α = 0.86 ± 0.04 × 10-4 K-1. The Fe-C density abruptly increases at pressures between 4.3 and 5.5 GPa in the range of present temperatures. Compared with the results of previous density measurements of liquid Fe-C, the effect of carbon on the density of liquid Fe shows a nonideal mixing behavior. The abrupt density increase and nonideal mixing behavior are important factors in determining the light element content in the Earth’s core.

  9. Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K

    International Nuclear Information System (INIS)

    Medvecz, P.J.; Nichols, K.M.

    1994-01-01

    Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO 2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm -1 ) while the CO 2 vibrational-rotational lines were from the far wing of the R branch of the ν 3 fundamental band (2395--2380 cm -1 ). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO 2 /N 2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak overlap. Line strength measurements were made from the corrected peaks by using the Bouguer-Lambert law and assuming a Lorentzian line profile. The experimentally obtained line strengths were evaluated by statistical calculations, by consideration of the validity of the Bouguer-Lambert assumption for these data, by comparison with existing room-temperature and high-temperature data, and by comparison with theoretical calculations. For CO, the statistical analysis suggests that the reported values have an uncertainty of ±10--12%, which is similar to the observed discrepancies with other reported values at room temperature. At high temperatures, the difference between these data and previously reported data and theoretical predictions is less than 10%. For CO 2 , the statistical uncertainty associated with the line strength calculations is less than 5%, which is also the approximate level of agreement with existing room-temperature data

  10. Temperature dependence of the bulk and surface properties of liquid Zn-Cd alloys

    Energy Technology Data Exchange (ETDEWEB)

    Awe, O.E. [University of Ibadan, Department of Physics, Ibadan (Nigeria); Azeez, A.A. [African University of Science and Technology, Abuja (Nigeria)

    2017-05-15

    The effects of temperature on the bulk and surface properties of liquid Zn-Cd alloys have been theoretically investigated, using a combination of self association model, Darken's thermodynamic equation for diffusion, empirical model for viscosity and a statistical mechanics model. The results from this study show that change in temperature resulted in cross-over effects in bulk and surface properties. We also found that with an increase in temperature, a pronounced asymmetry of viscosity isotherm is significantly reduced, and viscosity isotherm exhibited anomalous behaviour. Our results reveal that the homocoordination tendency in Zn-Cd liquid alloys is not strong and reduces with increasing temperature. The study further suggests a pronounced segregation of Cd-atoms at the surface of Zn-Cd liquid alloys and the extent of segregation reduces with temperature. We as well found that, in addition to the reported understanding that size-factor determines the compositional location of asymmetry of the viscosity isotherm, temperature is an operating parameter that has effect, not only on the composition of asymmetry, but also on the magnitude of asymmetry. In all the properties investigated, the most pronounced effect of temperature (52.9 %) is on the viscosity while the least effect (7.1 %) is on the surface tension. (orig.)

  11. Low-reflective wire-grid polarizers with absorptive interference overlayers

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motofumi [Department of Micro Engineering, Kyoto University, Kyoto 606-8501 (Japan); Takada, Akio; Yamada, Takatoshi; Hayasaka, Takashi; Sasaki, Kouji; Takahashi, Eiji; Kumagai, Seiji, E-mail: m-snki@me.kyoto-u.ac.jp [Devices Technology Department, Devices Division, Sony Chemical and Information Device Corporation, 3-4-1 Sakuragi, Tagajyo, Miyagi 985-0842 (Japan)

    2010-04-30

    Wire-grid (WG) polarizers with low reflectivity for visible light have been successfully developed. We theoretically consider the optical properties of simple sandwich structures of absorptive layer/transparent layer (gap layer)/high-reflective mirrors and found that it is possible to develop an antireflection (AR) coating owing to the interference along with the absorption in the absorptive layer. A wide variety of materials can be used for AR coatings by tuning the thicknesses of both the absorptive and the gap layers. This AR concept has been applied to reduce the reflectance of WG polarizers of Al. FeSi{sub 2} as an absorptive layer has been deposited by the glancing angle deposition technique immediately on the top of Al wires covered with a thin SiO{sub 2} layer as a gap layer. For the optimum combination of the thicknesses of FeSi{sub 2} and SiO{sub 2}, the reflectance becomes lower than a few per cent, independent of the polarization, whereas the transmission polarization properties remain good. Because low-reflective (LR) WG polarizers are completely composed of inorganic materials, they are useful for applications requiring high-temperature durability such as liquid crystal projection displays.

  12. Laser-induced separation of hydrogen isotopes in the liquid phase

    International Nuclear Information System (INIS)

    Beattie, W.; Freund, S.; Holland, R.; Maier, W.

    1980-01-01

    A process for separating hydrogen isotopes which comprises (A) forming a liquid phase of hydrogen-bearing feedstock compound at a temperature at which the spectral features of the feedstock compound are narrow enough or the absorption edges sharp enough to permit spectral features corresponding to the different hydrogen isotopes to be separated to be distinguished, (B) irradiating the liquid phase at said temperature with monochromatic radiation of a first wavelength which selectively or at least preferentially excites those molecules of said feedstock compound containing a first hydrogen isotope, and (C) subjecting the excited molecules to physical or chemical processes or a combination thereof whereby said first hydrogen isotope contained in said excited molecules is separated from other hydrogen isotopes contained in the unexcited molecules in said liquid phase

  13. Modeling of the fluid dynamics and SO{sub 2} absorption in a gas-liquid reactor

    Energy Technology Data Exchange (ETDEWEB)

    Marocco, L. [Alstom Power Italy, Milan (Italy)

    2010-08-01

    This paper illustrates a computational fluid dynamic (CFD) model of a counter-current Open Spray Tower desulphurisation reactor and its application in the simulation of a full-scale industrial equipment. The raw flue gas flows upward while a suspension of water and limestone is sprayed downward from different heights. Thereby sulfur dioxide is washed out of the gas. The two-phase gas-liquid flow inside the equipment has been simulated with an Euler-Lagrange approach using a commercial CFD code, while a model for the SO{sub 2} absorption has been developed and implemented in the software through dedicated modules. Physical absorption is modeled using dual-film theory and appropriate empirical and semi-empirical correlations. The aqueous phase chemistry accounts for the instantaneous equilibrium reactions of eight dissolved species into a slurry droplet. The model is used to simulate an industrial plant at different operating conditions. The numerical results are in good agreement with the measured values of pressure drop and sulphur removal efficiency.

  14. Absorption spectra between 0.8 {mu} and 30 {mu} of mixtures of H{sub 2}O - D{sub 2}O in the liquid state; Le spectre d'absorption des melanges H{sub 2}O-D{sub 2}O a l'etat liquide entre 0,8 et 30 {mu}

    Energy Technology Data Exchange (ETDEWEB)

    Ceccaldi, M; Goldman, M; Roth, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    There has been very little work carried out recently on the absorption bands of H{sub 2}O, HDO and D{sub 2}O in the liquid state. We have established the spectra of these molecules in between 0.8 and 30 p. The table of absorption bands of the molecules HDO and D{sub 2}O for which all the bands corresponding to those for H{sub 2}O had not been established has been completed. We have sought a convenient method of representing the variations in optical density of certain HDO bands as a function of the concentration of heavy water in the mixtures studied. (author) [French] Il y a peu de travaux recents sur les bandes d'absorption de H{sub 2}O, HDO et D{sub 2}O a l'etat liquide. Nous avons releve les spectres de ces molecules entre 0,8 et 30 p. Le tableau des bandes d'absorption des molecules HDO et D{sub 2}O, pour lesquelles le releve de toutes les bandes correspondantes a celles de H{sub 2}O n'etait pas encore effectue, a ete complete. Nous avons cherche des modes de representation commodes des variations de densite optique de certaines bandes de HDO en fonction de la teneur en eau lourde des melanges etudies. (auteur)

  15. Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples

    International Nuclear Information System (INIS)

    Li Shengqing; Cai Shun; Hu Wei; Chen Hao; Liu Hanlan

    2009-01-01

    A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF 6 ), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium-DDTC complex was formed and extracted into the fine droplets of HMIMPF 6 . After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 μL of HMIMPF 6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L - 1 , and the characteristic mass (m 0 , 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L - 1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2-106%.

  16. Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

    Science.gov (United States)

    Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick

    2001-01-01

    We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

  17. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review.

    Science.gov (United States)

    de la Calle, Inmaculada; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2016-09-14

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Ionic Liquids for Utilization of Waste Heat from Distributed Power Generation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Joan F. Brennecke; Mihir Sen; Edward J. Maginn; Samuel Paolucci; Mark A. Stadtherr; Peter T. Disser; Mike Zdyb

    2009-01-11

    The objective of this research project was the development of ionic liquids to capture and utilize waste heat from distributed power generation systems. Ionic Liquids (ILs) are organic salts that are liquid at room temperature and they have the potential to make fundamental and far-reaching changes in the way we use energy. In particular, the focus of this project was fundamental research on the potential use of IL/CO2 mixtures in absorption-refrigeration systems. Such systems can provide cooling by utilizing waste heat from various sources, including distributed power generation. The basic objectives of the research were to design and synthesize ILs appropriate for the task, to measure and model thermophysical properties and phase behavior of ILs and IL/CO2 mixtures, and to model the performance of IL/CO2 absorption-refrigeration systems.

  19. Liquid–liquid extraction of Pu(IV), U(VI) and Am(III) using malonamide in room temperature ionic liquid as diluent

    International Nuclear Information System (INIS)

    Rout, Alok; Venkatesan, K.A.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2012-01-01

    Highlights: ► Extraction of actinides using malonamide in room temperature ionic liquid. ► High distribution ratios of actinides in room temperature ionic liquid. ► Ion exchange mechanism. ► Stoichiometry of extraction. ► High separation factors of U(VI) and Pu(IV) over Am(III) and fission products. - Abstract: The extraction behavior of U(VI), Pu(IV) and Am(III) from nitric acid medium by a solution of N,N-dimethyl-N,N-dioctyl-2-(2-hexyloxyethyl)malonamide (DMDOHEMA) in the room temperature ionic liquid, 1–butyl–3–methylimidazolium bis(trifluoromethanesulfonyl)imide (C 4 mimNTf 2 ), was studied. The distribution ratio of these actinides in DMDOHEMA/C 4 mimNTf 2 was measured as a function of various parameters such as the concentration of nitric acid, DMDOHEMA, NTf 2 − , alkyl chain length of ionic liquid. The extraction of actinides in the absence of DMDOHEMA was insignificant and the distribution ratio achieved in conjunction with C 4 mimNTf 2 , was remarkable. The separation factor of U(VI) and Pu(IV) achieved with the use of DMDOHEMA, ionic liquid was compared with Am(III) and other fission products. The stoichiometry of the metal-solvate was determined to be 1:2 for U(VI) and Pu(IV) and 1:3 for Am(III).

  20. Effect of temperature on the morphology and electro-optical properties of liquid crystal physical gel

    International Nuclear Information System (INIS)

    Leaw, W.L.; Mamat, C.R.; Triwahyono, S.; Jalil, A.A.; Bidin, N.

    2016-01-01

    Liquid crystal physical gels were (thermally) prepared with cholesteryl stearate as a gelator in nematic liquid crystal, 4-cyano-4′-pentylbiphenyl. The electro-optical performance of liquid crystal physical gels is almost entirely dependent on the gels' inherent morphology. This study involved an empirical investigation of the relationships among all of the gelation temperature, morphology, and electro-optical properties. Besides continuous cooling at room temperature, isothermal cooling was also performed at both 18 and 0 °C, corresponding to near-solid and solid phases of 4-cyano-4′-pentylbiphenyl respectively. Nevertheless, the liquid crystal physical gel was also isothermally rapidly cooled using liquid nitrogen. Polarizing optical microscopy showed that the gel structure became thinner when isothermal cooling was carried out. These thinner gel aggregates then interconnected to form larger liquid crystal domains. Moreover, it was also revealed that the gel networks were randomized. Electron spin resonance results showed that the liquid crystal director orientation was severely randomized in the presence of gel networks. Conversely, isothermal cooling using liquid nitrogen generated a higher liquid crystal director orientation order. The 6.0 wt% cholesteryl stearate/4-cyano-4′-pentylbiphenyl physical gel that was isothermally cooled using liquid nitrogen showed the lowest response time in a twisted nematic mode optical cell. - Graphical abstract: Liquid crystal physical gel was prepared using nematic liquid crystal, 4-cyano-4′-pentylbiphenyl and cholesteryl stearate as gelator. Isothermal cooling at lower temperature produced thinner gel network and larger liquid crystal domain. - Highlights: • 5CB nematic liquid crystal was successfully gelled by cholesteryl stearate gelator. • The morphology of gel network was controlled by different cooling conditions. • Thinner gel network was formed by the rapid cooling using liquid nitrogen. • Enhanced

  1. Effect of temperature on the morphology and electro-optical properties of liquid crystal physical gel

    Energy Technology Data Exchange (ETDEWEB)

    Leaw, W.L. [Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia); Mamat, C.R., E-mail: che@kimia.fs.utm.my [Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia); Triwahyono, S. [Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia); Jalil, A.A. [Department of Chemical Engineering, Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia); Centre of Hydrogen Energy, Institute of Future Energy, Univerisiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia); Bidin, N. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310, UTM Johor Bahru, Johor (Malaysia)

    2016-12-01

    Liquid crystal physical gels were (thermally) prepared with cholesteryl stearate as a gelator in nematic liquid crystal, 4-cyano-4′-pentylbiphenyl. The electro-optical performance of liquid crystal physical gels is almost entirely dependent on the gels' inherent morphology. This study involved an empirical investigation of the relationships among all of the gelation temperature, morphology, and electro-optical properties. Besides continuous cooling at room temperature, isothermal cooling was also performed at both 18 and 0 °C, corresponding to near-solid and solid phases of 4-cyano-4′-pentylbiphenyl respectively. Nevertheless, the liquid crystal physical gel was also isothermally rapidly cooled using liquid nitrogen. Polarizing optical microscopy showed that the gel structure became thinner when isothermal cooling was carried out. These thinner gel aggregates then interconnected to form larger liquid crystal domains. Moreover, it was also revealed that the gel networks were randomized. Electron spin resonance results showed that the liquid crystal director orientation was severely randomized in the presence of gel networks. Conversely, isothermal cooling using liquid nitrogen generated a higher liquid crystal director orientation order. The 6.0 wt% cholesteryl stearate/4-cyano-4′-pentylbiphenyl physical gel that was isothermally cooled using liquid nitrogen showed the lowest response time in a twisted nematic mode optical cell. - Graphical abstract: Liquid crystal physical gel was prepared using nematic liquid crystal, 4-cyano-4′-pentylbiphenyl and cholesteryl stearate as gelator. Isothermal cooling at lower temperature produced thinner gel network and larger liquid crystal domain. - Highlights: • 5CB nematic liquid crystal was successfully gelled by cholesteryl stearate gelator. • The morphology of gel network was controlled by different cooling conditions. • Thinner gel network was formed by the rapid cooling using liquid nitrogen.

  2. Thermodynamic performance optimization of the absorption-generation process in an absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Chen, Yi; Han, Wei; Jin, Hongguang

    2016-01-01

    Highlights: • This paper proposes a new thermal compressor model with boost pressure ratio. • The proposed model is an effective way to optimize the absorption-generation process. • Boost pressure ratio is a key parameter in the proposed thermal compressor model. • The optimum boost pressure ratios for two typical refrigeration systems are obtained. - Abstract: The absorption refrigeration cycle is a basic cycle that establishes the systems for utilizing mid-low temperature heat sources. A new thermal compressor model with a key parameter of boost pressure ratio is proposed to optimize the absorption-generation process. The ultimate generation pressure and boost pressure ratio are used to represent the potential and operating conditions of the thermal compressor, respectively. Using the proposed thermal compressor model, the operation mechanism and requirements of the absorption refrigeration system and absorption-compression refrigeration system are elucidated. Furthermore, the two typical heat conversion systems are optimized based on the thermal compressor model. The optimum boost pressure ratios of the absorption refrigeration system and the absorption-compression refrigeration system are 0.5 and 0.75, respectively. For the absorption refrigeration system, the optimum generation temperature is 125.31 °C at the cooling water temperature of 30 °C, which is obtained by simple thermodynamic calculation. The optimized thermodynamic performance of the absorption-compression refrigeration system is 16.7% higher than that of the conventional absorption refrigeration system when the generation temperature is 100 °C. The thermal compressor model proposed in this paper is an effective method for simplifying the optimization of the thermodynamic systems involving an absorption-generation process.

  3. Ultrasound and orientational relaxation of nematic liquid crystals at high pressure

    International Nuclear Information System (INIS)

    Khabibullaev, P.K.; Oribjonov, Kh.J.; Lagunov, A.S.

    2004-01-01

    The acoustic properties of the nematic liquid crystal N-96 and its benzene solution in anisotropic phase are investigated in rotational magnetic field. The effects of concentration, temperature, pressure, and frequency of magnetic field rotation on ultrasonic absorption anisotropy are studied. Critical frequency values are experimentally determined. The relationship between the diamagnetic susceptibility anisotropy rotational viscosities was calculated, and its dependences on the pressure and temperature are also discussed. (author)

  4. Absorption of carbon dioxide and isotope exchange rate of carbon in a reaction system between carbon dioxide and carbamic acid

    International Nuclear Information System (INIS)

    Takeshita, Kenji; Kitamoto, Asashi

    1985-01-01

    The performance of isotope separation of carbon-13 by chemical exchange between carbon dioxide and carbamic acid was studied. The working fluid used in the study was a solution of DNBA, (C 4 H 9 ) 2 NH and n-octane mixture. Factors related to the isotope exchange rate were measured, such as the absorption rate of carbon dioxide into the solution of DNBA and n-octane, the isotope exchange rate and the separation factor in the reaction between CO 2 and carbamic acid. The absorption of CO 2 into the working fluid was the sum of chemical absorption by DNBA and physical absorption by n-octane. The absorption of carbon dioxide into the working fluid was negligible at temperatures over 90 0 C, but increased gradually at lower temperatures. Carbon dioxide was absorbed into DNBA by chemical absorption, and DNBA was converted to carbamic acid by the reaction. The reaction for synthesis and decomposition of carbamic acid was reversible. The separation factor in equilibrium reached a large value at lower temperatures. The isotope exchange rate between gas and liquid was proportional to the product of the concentration of carbamic acid and the concentration of CO 2 by physical absorption. The isotope separation of carbon by chemical exchange reaction is better operated under the conditions of lower temperature and higher pressure. (author)

  5. Room temperature ionic liquids: A simple model. Effect of chain length and size of intermolecular potential on critical temperature.

    Science.gov (United States)

    Chapela, Gustavo A; Guzmán, Orlando; Díaz-Herrera, Enrique; del Río, Fernando

    2015-04-21

    A model of a room temperature ionic liquid can be represented as an ion attached to an aliphatic chain mixed with a counter ion. The simple model used in this work is based on a short rigid tangent square well chain with an ion, represented by a hard sphere interacting with a Yukawa potential at the head of the chain, mixed with a counter ion represented as well by a hard sphere interacting with a Yukawa potential of the opposite sign. The length of the chain and the depth of the intermolecular forces are investigated in order to understand which of these factors are responsible for the lowering of the critical temperature. It is the large difference between the ionic and the dispersion potentials which explains this lowering of the critical temperature. Calculation of liquid-vapor equilibrium orthobaric curves is used to estimate the critical points of the model. Vapor pressures are used to obtain an estimate of the triple point of the different models in order to calculate the span of temperatures where they remain a liquid. Surface tensions and interfacial thicknesses are also reported.

  6. Graphical expression of thermodynamic characteristics of absorption process in ammonia-water system

    Directory of Open Access Journals (Sweden)

    Fortelný Zdeněk

    2012-04-01

    Full Text Available The adiabatic sorption is very interesting phenomenon that occurs when vapor of refrigerant is in contact with unsaturated liquid absorbent-refrigerant mixture and exchange of heat is forbid between the system and an environment. This contribution introduces new auxiliary lines that enable correct position determination of the adiabatic sorption process in the p-T-x diagram of ammoniawater system. The presented auxiliary lines were obtained from common functions for fast calculation of water-ammonia system properties. Absorption cycles designers often utilize p-t-x diagrams of working mixtures for first suggestion of new absorption cycles. The p-t-x diagrams enable fast correct determination of saturate states of liquid (and gaseous mixtures of refrigerants and absorbents. The working mixture isn’t only at saturated state during a real working cycle. If we know pressure and temperature of an unsaturated mixture, exact position determination is possible in the p-t-x diagrams too.

  7. Some new fatigue tests in high temperature water and liquid sodium environment

    International Nuclear Information System (INIS)

    Hattori, Takahiro; Yamauchi, Takayoshi; Kanasaki, Hiroshi; Kondo, Yoshiyuki; Endo, Tadayoshi.

    1987-01-01

    To evaluate the fatigue strength of structural materials for PWR or FBR plants, fatigue test data must be obtained in an environment of simulated primary and secondary water for PWR or of high temperature liquid sodium for FBR. Generally, such tests make it necessary to prepare expensive facilities, so when large amount of fatigue data are required, it is necessary to rationalize and simplify the fatigue tests while maintaining high accuracy. At the Takasago Research Development Center, efforts to rationalize facilities and maintain accuracy in fatigue tests have been made by developing new test methods and improving conventional techniques. This paper introduces a new method of low cycle fatigue test in high temperature water, techniques for automatic measurement of crack initiation and propagation in high temperature water environment and a multiple type fatigue testing machine for high temperature liquid sodium. (author)

  8. Temperature effects on the behavior of liquid hydrogen isotopes inside a spherical-shell directly driven inertial confinement fusion target

    International Nuclear Information System (INIS)

    Kim, K.; Mok, L.S.

    1984-05-01

    The present work studies the temperature effects on the formation of a uniform liquid hydrogen layer inside a spherical glass shell (SGS). The profile of the liquid layer is first investigated for an isothermal case. An equation suitable for describing the profile is derived by including the London-van der Waals attractive forces between the liquid and substrate molecules. Two theoretical models are then established to explain the changes in the liquid layer profile under the influence of a vertically applied temperature gradient. The characteristics of the fluid flows are obtained by solving the fluid equations under the low-Reynolds-number approximations. The effect of the component separation both in the liquid layer and the vapor region, which is induced by the temperature gradient, is studied when the enclosure inside the SGS is a mixture of hydrogen isotopes. A uniform layer can also be formed for the mixture liquid except that the required temperature gradient is now positive in direction, unlike the case of the single-component liquid. The heating effect due to the radioactive decay of tritium is also evaluated. An experimental apparatus capable of generating a desired temperature gradient across the SGS at liquid hydrogen temperatures is described. The profiles of the liquid layer are observed for different temperature gradients and the results are in qualitative agreement with the theoretical predictions

  9. Ultrasensitive Mach-Zehnder Interferometric Temperature Sensor Based on Liquid-Filled D-Shaped Fiber Cavity

    Directory of Open Access Journals (Sweden)

    Hui Zhang

    2018-04-01

    Full Text Available A liquid-filled D-shaped fiber (DF cavity serving as an in-fiber Mach–Zehnder interferometer (MZI has been proposed and experimentally demonstrated for temperature sensing with ultrahigh sensitivity. The miniature MZI is constructed by splicing a segment of DF between two single-mode fibers (SMFs to form a microcavity (MC for filling and replacement of various refractive index (RI liquids. By adjusting the effective RI difference between the DF and MC (the two interference arms, experimental and calculated results indicate that the interference spectra show different degrees of temperature dependence. As the effective RI of the liquid-filled MC approaches that of the DF, temperature sensitivity up to −84.72 nm/°C with a linear correlation coefficient of 0.9953 has been experimentally achieved for a device with the MC length of 456 μm, filled with liquid RI of 1.482. Apart from ultrahigh sensitivity, the proposed MCMZI device possesses additional advantages of its miniature size and simple configuration; these features make it promising and competitive in various temperature sensing applications, such as consumer electronics, biological treatments, and medical diagnosis.

  10. Ultrasensitive Mach-Zehnder Interferometric Temperature Sensor Based on Liquid-Filled D-Shaped Fiber Cavity.

    Science.gov (United States)

    Zhang, Hui; Gao, Shecheng; Luo, Yunhan; Chen, Zhenshi; Xiong, Songsong; Wan, Lei; Huang, Xincheng; Huang, Bingsen; Feng, Yuanhua; He, Miao; Liu, Weiping; Chen, Zhe; Li, Zhaohui

    2018-04-17

    A liquid-filled D-shaped fiber (DF) cavity serving as an in-fiber Mach–Zehnder interferometer (MZI) has been proposed and experimentally demonstrated for temperature sensing with ultrahigh sensitivity. The miniature MZI is constructed by splicing a segment of DF between two single-mode fibers (SMFs) to form a microcavity (MC) for filling and replacement of various refractive index (RI) liquids. By adjusting the effective RI difference between the DF and MC (the two interference arms), experimental and calculated results indicate that the interference spectra show different degrees of temperature dependence. As the effective RI of the liquid-filled MC approaches that of the DF, temperature sensitivity up to −84.72 nm/°C with a linear correlation coefficient of 0.9953 has been experimentally achieved for a device with the MC length of 456 μm, filled with liquid RI of 1.482. Apart from ultrahigh sensitivity, the proposed MCMZI device possesses additional advantages of its miniature size and simple configuration; these features make it promising and competitive in various temperature sensing applications, such as consumer electronics, biological treatments, and medical diagnosis.

  11. Dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous separation/preconcentration of nickel, cobalt and copper prior to determination by electrothermal atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mooud Amirkavei

    2013-01-01

    Full Text Available A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.

  12. A novel oxidative method for the absorption of Hg0 from flue gas of coal fired power plants using task specific ionic liquid scrubber

    International Nuclear Information System (INIS)

    Barnea, Zach; Sachs, Tatyana; Chidambaram, Mandan; Sasson, Yoel

    2013-01-01

    Highlights: ► Ionic liquid used as absorption media due to negligible vapor pressure. ► Formation of a stable complex between the oxidation agent and the absorption liquid prevents its sublimation. ► Remarkable concentration factor of six orders of magnitude of mercury/IL unlike active carbon injection that absorb ppb of Hg from flue. ► Reduced metallic mercury swiftly precipitated from the solution and could be quantitatively separated and collected. -- Abstract: A simple continuous process is described for the removal of mercury from gas streams (such as flue gas of a coal fired power stations) using imidazolium based Task Specific Ionic Liquids [TSILs] with the general structure ([RMIM][XI 2 − ]) where X = Cl, Br or I. The latter are formed by blending dialkylimidazolium halide salts with iodine. When applied in a gas/liquid scrubber, these salts were shown to absorb >99% of elemental mercury originally present in a gas stream in concentration of 75–400 ppb. The mercury abatement is attained by oxidating the mercury to HgI 2 which is bound as a stable IL complex ([RMIM + ][XHgI 2 − ]. The novel absorption system exhibits a remarkable mercury concentration factor of seven orders of magnitude. The final solution obtained contains up to 50% (w/w) mercury in the IL. Upon exposure to sodium formate, directly added to the saturated IL at 45 °C, reduced metallic mercury swiftly precipitated from the solution and could be quantitatively separated and collected. The free IL could be fully recycled

  13. NF3: UV Absorption Spectrum Temperature Dependence and the Atmospheric and Climate Forcing Implications

    Science.gov (United States)

    Papadimitriou, Vassileios C.; McGillen, Max R.; Fleming, Eric L.; Jackman, Charles H.; Burkholder, James B.

    2013-01-01

    Nitrogen trifluoride (NF3) is an atmospherically persistent greenhouse gas that is primarily removed by UV photolysis and reaction with O((sup 1)D) atoms. In this work, the NF3 gas-phase UV absorption spectrum, sigma(delta,T), was measured at 16 wavelengths between 184.95 and 250 nm at temperatures between 212 and 296 K. A significant spectrum temperature dependence was observed in the wavelength region most relevant to atmospheric photolysis (200-220 nm) with a decrease in sigma(210 nm,T) of approximately 45 percent between 296 and 212 K. Atmospheric photolysis rates and global annually averaged lifetimes of NF3 were calculated using the Goddard Space Flight Center 2-D model and the sigma(delta,T) parameterization developed in this work. Including the UV absorption spectrum temperature dependence increased the stratospheric photolysis lifetime from 610 to 762 years and the total global lifetime from 484 to 585 years; the NF3 global warming potentials on the 20-, 100-, and 500-year time horizons increased less than 0.3, 1.1, and 6.5 percent to 13,300, 17,700, and 19,700, respectively.

  14. Temperature-Responsive Luminescent Solar Concentrators: Tuning Energy Transfer in a Liquid Crystalline Matrix.

    Science.gov (United States)

    Sol, Jeroen A H P; Dehm, Volker; Hecht, Reinhard; Würthner, Frank; Schenning, Albertus P H J; Debije, Michael G

    2018-01-22

    Temperature-responsive luminescent solar concentrators (LSCs) have been fabricated in which the Förster resonance energy transfer (FRET) between a donor-acceptor pair in a liquid crystalline solvent can be tuned. At room temperatures, the perylene bisimide (PBI) acceptor is aggregated and FRET is inactive; while after heating to a temperature above the isotropic phase of the liquid crystal solvent, the acceptor PBI completely dissolves and FRET is activated. This unusual temperature control over FRET was used to design a color-tunable LSC. The device has been shown to be highly stable towards consecutive heating and cooling cycles, making it an appealing device for harvesting otherwise unused solar energy. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  15. Communication: Anomalous temperature dependence of the intermediate range order in phosphonium ionic liquids

    International Nuclear Information System (INIS)

    Hettige, Jeevapani J.; Kashyap, Hemant K.; Margulis, Claudio J.

    2014-01-01

    In a recent article by the Castner and Margulis groups [Faraday Discuss. 154, 133 (2012)], we described in detail the structure of the tetradecyltrihexylphosphonium bis(trifluoromethylsulfonyl)-amide ionic liquid as a function of temperature using X-ray scattering, and theoretical partitions of the computationally derived structure function. Interestingly, and as opposed to the case in most other ionic-liquids, the first sharp diffraction peak or prepeak appears to increase in intensity as temperature is increased. This phenomenon is counter intuitive as one would expect that intermediate range order fades as temperature increases. This Communication shows that a loss of hydrophobic tail organization at higher temperatures is counterbalanced by better organization of polar components giving rise to the increase in intensity of the prepeak

  16. Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Man Su; Park, Hana; Yoo, Don Gyu; Jeong, Sang Kwon [Cryogenic Engineering Laboratory, Department of Mechanical Engineering, KAIST, Daejeon (Korea, Republic of); Jung, Young Suk [Launcher Systems Development Team, Korea Aerospace Research Institute, Daejeon (Korea, Republic of)

    2014-06-15

    Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid.

  17. Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

    International Nuclear Information System (INIS)

    Seo, Man Su; Park, Hana; Yoo, Don Gyu; Jeong, Sang Kwon; Jung, Young Suk

    2014-01-01

    Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid

  18. An ultrasound-based liquid pressure measurement method in small diameter pipelines considering the installation and temperature.

    Science.gov (United States)

    Li, Xue; Song, Zhengxiang

    2015-04-09

    Liquid pressure is a key parameter for detecting and judging faults in hydraulic mechanisms, but traditional measurement methods have many deficiencies. An effective non-intrusive method using an ultrasound-based technique to measure liquid pressure in small diameter (less than 15 mm) pipelines is presented in this paper. The proposed method is based on the principle that the transmission speed of an ultrasonic wave in a Kneser liquid correlates with liquid pressure. Liquid pressure was calculated using the variation of ultrasonic propagation time in a liquid under different pressures: 0 Pa and X Pa. In this research the time difference was obtained by an electrical processing approach and was accurately measured to the nanosecond level through a high-resolution time measurement module. Because installation differences and liquid temperatures could influence the measurement accuracy, a special type of circuit called automatic gain control (AGC) circuit and a new back propagation network (BPN) model accounting for liquid temperature were employed to improve the measurement results. The corresponding pressure values were finally obtained by utilizing the relationship between time difference, transient temperature and liquid pressure. An experimental pressure measurement platform was built and the experimental results confirm that the proposed method has good measurement accuracy.

  19. Resonance absorption measurements of atom concentrations in reacting gas mixtures. II. Calibration of microwave sources over a wide temperature range

    International Nuclear Information System (INIS)

    Chiang, C.; Lifshitz, A.; Skinner, G.B.; Wood, D.R.

    1979-01-01

    A series of experiments was carried out to calibrate three different microwave discharge lamps for analysis for D or H atoms, using Lyman-α absorption. Known concentrations of D atoms were produced in a shock tube by the reaction of 0.05--4 ppm D 2 with N 2 O in argon at 1800--3000 K. H atoms were produced by dissociation of 2,2,3,3-tetramethylbutane (10 ppm in argon) at 980--1140 K. These absorption data were compared with the absorption calculated from Lyman-α line shapes reported in an earlier paper, good agreement being found. These experiments provide a sound basis for obtaining the temperature and concentration dependence of the absorption coefficient over a wide temperature range, for H and D concentrations between 10 -12 and 10 -10 mole/cc

  20. Trivalent europium speciation in a room-temperature ionic liquid

    International Nuclear Information System (INIS)

    Mekki, S.

    2006-10-01

    Since the nuclear industry is playing an important role in the power production field, a relevant number of problems have been revealed. Indeed, high-level radioactive long-lived nuclear wastes present a real difficulty for nuclear wastes management. Minor actinides, which compose most of these wastes, will be radioactive for several thousands of years. For eventual disposal deep underground, their reprocessing needs to be optimized. The extraction processes used industrially to separate actinides and lanthanides from other metal species characterizing the spent nuclear fuel produce, nevertheless, enormous quantities of contaminated liquid wastes directly issued from the liquid/liquid extraction step. During the last decade, some room-temperature ionic liquid have been studied and integrated into industrial processes. The interest on this class of solvent came out from their 'green' properties (non volatile, non flammable, recyclable, etc...), but also from the variability of their physico-chemical properties (stability, hydrophobicity, viscosity) as a function of the RTIL chemical composition. Indeed, it has been shown that classical chemical industrial processes could be transferred into those media, even more improved, while a certain number of difficulties arising from using traditional solvent can be avoided. In this respect, it could be promising to investigate the ability to use room-temperature ionic liquid into the spent nuclear fuel reprocessing field. The aim of this thesis is to test the ability of the specific ionic liquid bumimTf 2 N to allow trivalent europium extraction. The choice of this metal is based on the chemical analogy with trivalent minor actinides Curium and Americium which are contributing the greatest part of the long-lived high-level radioactive wastes. Handling these elements needs to be very cautious for the safety and radioprotection aspect. Moreover, europium is a very sensitive luminescent probe to its environment even at the

  1. Polarization versus Temperature in Pyridinium Ionic Liquids

    DEFF Research Database (Denmark)

    Chaban, V. V.; Prezhdo, O. V.

    2014-01-01

    Electronic polarization and charge transfer effects play a crucial role in thermodynamic, structural, and transport properties of room-temperature ionic liquids (RTILs). These nonadditive interactions constitute a useful tool for tuning physical chemical behavior of RTILs. Polarization and charge...... interactions changes negligibly between 300 and 900 K, while the average dipole moment increases due to thermal fluctuations of geometries. Our results contribute to the fundamental understanding of electronic effects in the condensed phase of ionic systems and foster progress in physical chemistry...

  2. Small-amplitude vibrations at a finite temperature in the liquid drop model

    International Nuclear Information System (INIS)

    Providencia, J. da Jr.

    1991-01-01

    The ground state of a hot nucleus is studied in the classical limit. The equations of motion and boundary conditions of the liquid drop model are derived from the variational principle. The effect of the surface tension is taken into account. The temperature dependence of small-amplitude vibrations in the liquid drop model is investigated. It is shown that the breathing mode suffers a 6.3% decrease in energy when the temperature increases from 0 to 5 MeV. The present model allows for a description of surface modes with an A -1/2 dependence of the energy. It is also found that the surface modes will show an appreciable temperature dependence if a reasonable temperature dependence of the surface tension is postulated. It is shown that the model satisfies the energy-weighted sum rule and the inverse energy-weighted sum rule. (orig.)D

  3. Observation of soft x-ray radiation from Heliotron E plasmas by the absorption method for the measurement of electron temperatures

    International Nuclear Information System (INIS)

    Kaneko, H.; Tohda, T.; Iiyoshi, A.

    1989-01-01

    An absorption method of soft x ray is applied to Heliotron E plasmas for measurement of the electron temperature. Nitrogen gas is used as an absorber for convenience, owing to its accurate, uniform, and easily controllable density. The general feature of the absorption method for measurement of the electron temperature is discussed using a model with two parameters: the generalized thickness of the absorber and the electron temperature. The energy resolution of this method is not sufficient as a general method for spectral analysis. Hence, it is necessary to assume in advance such a model spectrum as consists of bremsstrahlung, recombination radiation, and impurity line radiation. Since the spectrum is always assumed before the analysis, we should try to find the origins of deformation of the energy spectrum and to correct the contribution. The effect of line emission from impurity ions to the estimated electron temperature is evaluated as a function of the electron temperature and the energy of the line relative to the generalized absorber thickness used in the measurement. An actual spectrum is measured by a pulse-height analysis (PHA) of the soft x ray. The one clear line, from chlorine, is not significant in the present determination of the electron temperature by the absorption method. Another possible line from iron at energy less than 1 keV is included in the analysis. Using a convenient method for determination of local emissivity from a chord-integrated emissivity, the electron temperature is determined from the local emissivity. The observed broad electron-temperature profile might be an artifact due to recombination radiation of the highly ionized ion diffused out of the hot core of the plasma. It is confirmed that the absorption method gives absolute measurement of the electron temperature at the plasma center, when additional information on impurity lines are given by PHA

  4. Temperature-dependent thermo-elastic properties of s-, p- and d-block liquid metals

    International Nuclear Information System (INIS)

    Singh, R.N.; Arafin, S.; George, A.K.

    2007-01-01

    Thermodynamic relations involving experimentally known physical quantities are used to determine the ratio of specific heats, γ, for s-block (Na, K, Rb, Cs, Mg), d-block (Fe, Co, Ni, Cu, Ag, Au, Zn, Cd, Hg,) and p-block (Al, Ga, In, Tl, Sn, Pb, Sb, Bi, Se, Te) liquid metals. γ is further utilized to determine reliable values for the isothermal compressibility (κ T ) and the specific heat at constant volume (C V ) for these liquid metals near and above the melting temperatures. These data are of considerable significance for various thermo-physical analysis of liquid metals. We have also evaluated the Grueneisen function and its temperature dependence to establish the correlation between the thermal expansion and the elastic response to thermally induced stress. The values of acoustic impedance for liquid metals are evaluated and its physical significance is discussed for the transmission of elastic waves across metallic interfaces

  5. Effect of ambient temperature and relative humidity on interfacial temperature during early stages of drop evaporation.

    Science.gov (United States)

    Fukatani, Yuki; Orejon, Daniel; Kita, Yutaku; Takata, Yasuyuki; Kim, Jungho; Sefiane, Khellil

    2016-04-01

    Understanding drop evaporation mechanisms is important for many industrial, biological, and other applications. Drops of organic solvents undergoing evaporation have been found to display distinct thermal patterns, which in turn depend on the physical properties of the liquid, the substrate, and ambient conditions. These patterns have been reported previously to be bulk patterns from the solid-liquid to the liquid-gas drop interface. In the present work the effect of ambient temperature and humidity during the first stage of evaporation, i.e., pinned contact line, is studied paying special attention to the thermal information retrieved at the liquid-gas interface through IR thermography. This is coupled with drop profile monitoring to experimentally investigate the effect of ambient temperature and relative humidity on the drop interfacial thermal patterns and the evaporation rate. Results indicate that self-generated thermal patterns are enhanced by an increase in ambient temperature and/or a decrease in humidity. The more active thermal patterns observed at high ambient temperatures are explained in light of a greater temperature difference generated between the apex and the edge of the drop due to greater evaporative cooling. On the other hand, the presence of water humidity in the atmosphere is found to decrease the temperature difference along the drop interface due to the heat of adsorption, absorption and/or that of condensation of water onto the ethanol drops. The control, i.e., enhancement or suppression, of these thermal patterns at the drop interface by means of ambient temperature and relative humidity is quantified and reported.

  6. Temperature field in concrete when in contact with hot liquids

    International Nuclear Information System (INIS)

    Andrade Lima, F.R. de.

    1981-09-01

    In an HCDA (Hypothetical Core Disruptive Accident) it is postulated that liquid metal coolants and core materials come in contact with the retaining concrete structure. A mathematical model and an associated computer program was previously developed to describle the transient heat and mass transfer in the concrete. Implementations on the original program-USINT- are included to consider the variations of the thermal conductivity as a function of the temperature. Also a subroutine - PLOTTI - is incorporated to the program for the plotting of the results. The new program - USINTG - is used to calculate the temperature and pressure fields and the water released from concrete structures during a sodium leak simulation and with the concrete structures in contact with liquid sodium. No consideration about chemical reactions involving the sodium when in contact with concrete is considered. (Author) [pt

  7. Separation and determination of copper in bottled water samples by combination of dispersive liquid--liquid microextraction and microsample introduction flame atomic absorption spectrometry.

    Science.gov (United States)

    Citak, Demirhan; Tuzen, Mustafa

    2013-01-01

    A new and simple method for the determination of trace amounts of Cu(II) was developed by combination of dispersive liquid-liquid microextraction (DLLME) preconcentration and microsample introduction flame atomic absorption spectrometry. In this method, ethanol and chloroform were chosen as disperser and extraction solvents, respectively, and 1-nitroso-2-naphthol was used as the complexing agent. The factors affecting the extraction efficiency and determination of Cu(II), including extraction and disperser solvent nature and volume, concentration of the complexing agent, pH of the solution, extraction time, and matrix ions, were investigated. Under optimal conditions, the LOD for Cu(II) was 0.95 microg/L with a preconcentration factor of 70. The RSD was 1.9%. The accuracy of the developed DLLME method was verified by determination of Cu(II) in a certified reference material (NRCC-SLRS-4 river water). The relative error was -3.31%. The developed preconcentration procedure was successfully applied to the analysis of bottled drinking water samples.

  8. Measurement of laser absorptivity for operating parameters characteristic of laser drilling regime

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, M; Berthe, L; Fabbro, R; Muller, M [Laboratoire pour l' Application des Lasers de Puissance, UPR CNRS no1578, 16 Bis, Avenue Prieur de la Cote D' Or, 94114 Arcueil Cedex (France)], E-mail: matthieu.schneider@gmail.com

    2008-08-07

    Laser drilling in the percussion regime is commonly used in the aircraft industry to drill sub-millimetre holes in metallic targets. Characteristic laser intensities in the range of 10 MW cm{sup -2} are typically employed for drilling metallic targets. With these intensities the temperature of the irradiated matter is above the vaporization temperature and the drilling process is led by hydrodynamic effects. Although the main physical processes involved are identified, this process is not correctly understood or completely controlled. A major characteristic coefficient of laser-matter interaction for this regime, which is the absorptivity of the laser on the irradiated surface, is still unknown, because of the perturbing effects due to laser beam geometrical trapping inside the drilled hole. So, by using time resolved experiments, this study deals with the direct measurement of the variation of the intrinsic absorption of aluminium, nickel and steel materials, as a function of the incident laser intensity up to 20 MW cm{sup -2}. We observe that for this incident intensity, the absorptivity can reach up to 80%. This very high and unexpected value is discussed by considering the microscopic behaviour of the heated matter near the vapour-liquid interface that undergoes possible Rayleigh-Taylor instability or volume absorption.

  9. Measurement of laser absorptivity for operating parameters characteristic of laser drilling regime

    Science.gov (United States)

    Schneider, M.; Berthe, L.; Fabbro, R.; Muller, M.

    2008-08-01

    Laser drilling in the percussion regime is commonly used in the aircraft industry to drill sub-millimetre holes in metallic targets. Characteristic laser intensities in the range of 10 MW cm-2 are typically employed for drilling metallic targets. With these intensities the temperature of the irradiated matter is above the vaporization temperature and the drilling process is led by hydrodynamic effects. Although the main physical processes involved are identified, this process is not correctly understood or completely controlled. A major characteristic coefficient of laser-matter interaction for this regime, which is the absorptivity of the laser on the irradiated surface, is still unknown, because of the perturbing effects due to laser beam geometrical trapping inside the drilled hole. So, by using time resolved experiments, this study deals with the direct measurement of the variation of the intrinsic absorption of aluminium, nickel and steel materials, as a function of the incident laser intensity up to 20 MW cm-2. We observe that for this incident intensity, the absorptivity can reach up to 80%. This very high and unexpected value is discussed by considering the microscopic behaviour of the heated matter near the vapour-liquid interface that undergoes possible Rayleigh-Taylor instability or volume absorption.

  10. Improved operation of graded-channel SOI nMOSFETs down to liquid helium temperature

    Science.gov (United States)

    Pavanello, Marcelo Antonio; de Souza, Michelly; Ribeiro, Thales Augusto; Martino, João Antonio; Flandre, Denis

    2016-11-01

    This paper presents the operation of Graded-Channel (GC) Silicon-On-Insulator (SOI) nMOSFETs at low temperatures down to liquid helium temperature in comparison to standard uniformly doped transistors. Devices from two different technologies have been measured and show that the mobility increase rate with temperature for GC SOI transistors is similar to uniformly doped devices for temperatures down to 90 K. However, at liquid helium temperature the rate of mobility increase is larger in GC SOI than in standard devices because of the different mobility scattering mechanisms. The analog properties of GC SOI devices have been investigated down to 4.16 K and show that because of its better transconductance and output conductance, an intrinsic voltage gain improvement with temperature is also obtained for devices in the whole studied temperature range. GC devices are also capable of reducing the impact ionization due to the high electric field in the drain region, increasing the drain breakdown voltage of fully-depleted SOI MOSFETs at any studied temperature and the kink voltage at 4.16 K.

  11. The investigation of rf-squids at liquid nitrogen temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Polushkin, V N; Vasiliev, B V [Joint Inst. for Nuclear Research, Dubna (USSR)

    1989-12-01

    One- and two-hole YBCO ceramic rf-squids operating at liquid nitrogen temperatures have been developed. The main squid parameters: self-inductance, white noise level and magnetic flux resolution were measured. The directly measured external field sensitivity for one-hole squid was at the level of 100 fT/{radical}Hz. (orig.).

  12. Electromagnetic-acoustic coupling in ferromagnetic metals at liquid-helium temperatures

    DEFF Research Database (Denmark)

    Gordon, R A

    1981-01-01

    Electromagnetic-acoustic coupling at the surface and in the bulk of ferromagnetic metals at liquid-helium temperatures has been studied using electromagnetically excited acoustic standing-wave resonances at MHz frequencies in a number of ferromagnetic metals and alloys of commercial interest...

  13. Optical absorption measurement system

    International Nuclear Information System (INIS)

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  14. Effect of room temperature ionic liquid structure on the enzymatic acylation of flavonoids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing

    2010-01-01

    Enzymatic acylation reactions of flavonoids (rutin, esculin) with long chain fatty acids (palmitic, oleic acids) were carried out in 14 different ionic liquid media containing a range of cation and anion structures. Classification of RTILs according to flavonoid solubility (using COSMO...... must be struck that maximized flavonoid solubility with minimum negative impact on lipase activity. The process also benefitted from an increased reaction temperature which may have helped to reduced mass transfer limitations. Keywords: Room temperature ionic liquids (RTILs); Biosynthesis; Acylation......; Flavonoids; Lipase; Long chain fatty acids...

  15. Non-haloaluminate room-temperature ionic liquids in electrochemistry--a review.

    Science.gov (United States)

    Buzzeo, Marisa C; Evans, Russell G; Compton, Richard G

    2004-08-20

    Some twenty-five years after they first came to prominence as alternative electrochemical solvents, room temperature ionic liquids (RTILs) are currently being employed across an increasingly wide range of chemical fields. This review examines the current state of ionic liquid-based electrochemistry, with particular focus on the work of the last decade. Being composed entirely of ions and possesing wide electrochemical windows (often in excess of 5 volts), it is not difficult to see why these compounds are seen by electrochemists as attractive potential solvents. Accordingly, an examination of the pertinent properties of ionic liquids is presented, followed by an assessment of their application to date across the various electrochemical disciplines, concluding with an outlook viewing current problems and directions.

  16. Experimental evaluation of permanent magnet probe flowmeter measuring high temperature liquid sodium flow in the ITSL

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Uiju; Kim, Yun Ho [Nuclear engineering Department, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Kim, Jong-Man; Kim, Tae-Joon [Korea Atomic Energy Research Institute, 1045 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Sung Joong, E-mail: sungjkim@mit.edu [Nuclear engineering Department, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

    2013-12-15

    Highlights: • An Instrument Test Sodium Loop (ITSL) has been built and tested in various conditions at KAERI. • Free fall of liquid sodium was conducted experimentally and numerically. • A Permanent Magnet Probe Flowmeter (PMPF) was experimented in the ITSL. • Excellent linearity of the PMPF was achieved under high temperature condition. - Abstract: The Instrument Test Sodium Loop (ITSL) installed at Korea Atomic Energy Research Institute (KAERI) is a medium-size experimental facility dedicated to obtaining relevant experimental data of liquid sodium flow characteristics under various thermal hydraulic conditions and sodium purification. The ITSL has been utilized to perform thermal flow measurement of the liquid sodium and to calibrate a Permanent Magnet Probe Flowmeter (PMPF). The primary objective of this study is to obtain liquid sodium flow rate given a wide temperature range using the PMPF. Non-stationary method was adopted for the calibration of the probe given the liquid sodium temperature range of 150–415 °C. A relationship between the measured voltage signal and flow rate was obtained successfully. It is observed that the calibration experiments result in excellent linear relationships between measured voltage and volumetric flow rate at various temperature conditions. Also a computational analysis using FlowMaster, is employed to facilitate the calibration process by predicting the liquid sodium flow rate. Finally the effect of the fluid temperature on thermal flow measurements is discussed in light of the obtained experimental data.

  17. Cellulose gels produced in room temperature ionic liquids by ionizing radiation

    International Nuclear Information System (INIS)

    Kimura, Atsushi; Nagasawa, Naotsugu; Taguchi, Mitsumasa

    2014-01-01

    Cellulose-based gels were produced in room temperature ionic liquids (RTILs) by ionizing radiation. Cellulose was dissolved at the initial concentration of 20 wt% in 1-ethyl-3-methylimidazolium (EMI)-acetate or N,N-diethyl-N-methyl-N-(2-methoxyethyl)ammonium (DEMA)-formate with a water content of 18 wt%, and irradiated with γ-rays under aerated condition to produce new cellulose gels. The gel fractions of the cellulose gels obtained in EMI-acetate and DEMA-formate at a dose of 10 kGy were 13% and 19%, respectively. The formation of gel fractions was found to depend on the initial concentration of cellulose, water content, and irradiation temperature. The obtained gel readily absorbed water, methanol, ethanol, dichloromethane, N,N-dimethylacetamide, and RTILs. - Highlights: • Cellulose gels were produced in room temperature ionic liquids (RTILs). • Water plays a crucial role in the cross-linking reaction. • Cellulose gels swollen with RTILs show good electronic conductivity (3.0 mS cm −1 )

  18. Liquid Nitrogen Temperature Operation of a Switching Power Converter

    Science.gov (United States)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.

    1995-01-01

    The performance of a 42/28 V, 175 W, 50 kHz pulse-width modulated buck dc/dc switching power converter at liquid nitrogen temperature (LNT) is compared with room temperature operation. The power circuit as well as the control circuit of the converter, designed with commercially available components, were operated at LNT and resulted in a slight improvement in converter efficiency. The improvement in power MOSFET operation was offset by deteriorating performance of the output diode rectifier at LNT. Performance of the converter could be further improved at low temperatures by using only power MOSFET's as switches. The use of a resonant topology will further improve the circuit performance by reducing the switching noise and loss.

  19. Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

    Science.gov (United States)

    Martin, Marcel Nations; Chang, Leyen S.; Jeffries, Jay B.; Hanson, Ronald K.; Nawaz, Anuscheh; Taunk, Jaswinder S.; Driver, David M.; Raiche, George

    2013-01-01

    A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

  20. Experimental Determination of Temperatures in a Liquid GAP

    International Nuclear Information System (INIS)

    Masson, Viviana; Ojeda, Andres; Fabian, Bonetto

    2003-01-01

    An experimental study of heat transfer in a gap of water at atmospheric pressure is presented under natural convection conditions.The objective of the work was to experimentally determine the expected maximum temperatures in the gap for a given heater power.The experimental set-up was a plane surface heated by resistances and facing a 1mm-liquid gap.Visualisation of phenomena by video and still picture was performed

  1. Heat of Absorption of CO2 in Phase Change Solvents: 2-(Diethylamino)ethanol and 3-(Methylamino)propylamine

    DEFF Research Database (Denmark)

    Waseem Arshad, Muhammad; Fosbøl, Philip Loldrup; von Solms, Nicolas

    2013-01-01

    Heat of absorption of CO2 in phase change solvents containing 2-(diethylamino)ethanol (DEEA) and 3-(methylamino)propylamine (MAPA) were measured as a function of CO2 loading at different temperatures using a commercially available reaction calorimeter. The tested systems were aqueous single amines...... (5 M DEEA, 2 M MAPA, and 1 M MAPA) and aqueous amine mixtures (5 M DEEA + 2 M MAPA and 5 M DEEA + 1 M MAPA) which give two liquid phases on reacting with CO2. All parallel experiments have shown good repeatability. The measurements were taken isothermally at three different temperatures, (40, 80......, and 120) °C. The measured differential heat of absorption values were converted into integral values by integration. Heats of absorption of CO2 in aqueous single amines were affected by changing the solvent composition (large difference in concentrations) and CO2 feed pressure simultaneously. In addition...

  2. Time-resolved temperature measurements in a rapid compression machine using quantum cascade laser absorption in the intrapulse mode

    KAUST Repository

    Nasir, Ehson Fawad; Farooq, Aamir

    2016-01-01

    A temperature sensor based on the intrapulse absorption spectroscopy technique has been developed to measure in situ temperature time-histories in a rapid compression machine (RCM). Two quantum-cascade lasers (QCLs) emitting near 4.55μm and 4.89μm

  3. Levitation of Liquid Microdroplets Above A Solid Surface Subcooled to the Leidenfrost Temperature

    Directory of Open Access Journals (Sweden)

    Kirichenko D. P.

    2016-01-01

    Full Text Available Evaporation of liquid microdroplets that fall on a solid surface with the temperature of below the Leidenfrost temperature is studied. It has been found out that sufficiently small liquid droplets of about 10 microns can suspend at some distance from the surface (levitate and do not reach the surface; at that, the rate of droplet evaporation is reduced by an order as compared to microdroplets, which touch the surface. It is determined that in contrast to microdroplets, which touch the surface, the specific evaporation rate of levitating droplets is constant in time.

  4. Ionic Liquid (1-Butyl-3-Metylimidazolium Methane Sulphonate Corrosion and Energy Analysis for High Pressure CO2 Absorption Process

    Directory of Open Access Journals (Sweden)

    Aqeel Ahmad Taimoor

    2018-05-01

    Full Text Available This study explores the possible use of ionic liquids as a solvent in a commercial high-pressure CO2 removal process, to gain environmental and energy benefits. There are two main constraints in realizing this: ionic liquids can be corrosive, specifically when mixed with a water/amine solution with dissolved O2 & CO2; and CO2 absorption within this process is not very well understood. Therefore, scavenging CO2 to ppm levels from process gas comes with several risks. We used 1-butyl-3-methylimidazoium methane sulphonate [bmim][MS] as an ionic liquid because of its high corrosiveness (due to its acidic nature to estimate the ranges of expected corrosion in the process. TAFEL technique was used to determine these rates. Further, the process was simulated based on the conventional absorption–desorption process using ASPEN HYSYS v 8.6. After preliminary model validation with the amine solution, [bmim][MS] was modeled based on the properties found in the literature. The energy comparison was then provided and the optimum ratio of the ionic liquid/amine solution was calculated.

  5. The effect of cloud liquid water on tropospheric temperature retrievals from microwave measurements

    Directory of Open Access Journals (Sweden)

    L. Bernet

    2017-11-01

    Full Text Available Microwave radiometry is a suitable technique to measure atmospheric temperature profiles with high temporal resolution during clear sky and cloudy conditions. In this study, we included cloud models in the inversion algorithm of the microwave radiometer TEMPERA (TEMPErature RAdiometer to determine the effect of cloud liquid water on the temperature retrievals. The cloud models were built based on measurements of cloud base altitude and integrated liquid water (ILW, all performed at the aerological station (MeteoSwiss in Payerne (Switzerland. Cloud base altitudes were detected using ceilometer measurements while the ILW was measured by a HATPRO (Humidity And Temperature PROfiler radiometer. To assess the quality of the TEMPERA retrieval when clouds were considered, the resulting temperature profiles were compared to 2 years of radiosonde measurements. The TEMPERA instrument measures radiation at 12 channels in the frequency range from 51 to 57 GHz, corresponding to the left wing of the oxygen emission line complex. When the full spectral information with all the 12 frequency channels was used, we found a marked improvement in the temperature retrievals after including a cloud model. The chosen cloud model influenced the resulting temperature profile, especially for high clouds and clouds with a large amount of liquid water. Using all 12 channels, however, presented large deviations between different cases, suggesting that additional uncertainties exist in the lower, more transparent channels. Using less spectral information with the higher, more opaque channels only also improved the temperature profiles when clouds where included, but the influence of the chosen cloud model was less important. We conclude that tropospheric temperature profiles can be optimized by considering clouds in the microwave retrieval, and that the choice of the cloud model has a direct impact on the resulting temperature profile.

  6. Chemical Absorption Materials

    DEFF Research Database (Denmark)

    Thomsen, Kaj

    2011-01-01

    Chemical absorption materials that potentially can be used for post combustion carbon dioxide capture are discussed. They fall into five groups, alkanolamines, alkali carbonates, ammonia, amino acid salts, and ionic liquids. The chemistry of the materials is discussed and advantages and drawbacks...

  7. Hollow fiber based liquid-phase microextraction for the determination of mercury traces in water samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Garcia, Ignacio; Rivas, Ricardo E. [Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence ' Campus Mare Nostrum' , University of Murcia, E-30071 Murcia (Spain); Hernandez-Cordoba, Manuel, E-mail: hcordoba@um.es [Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence ' Campus Mare Nostrum' , University of Murcia, E-30071 Murcia (Spain)

    2012-09-19

    Highlight: Black-Right-Pointing-Pointer Hg (II) traces are preconcentrated by means of a three-phase liquid microextraction system. Black-Right-Pointing-Pointer PAN and ammonium iodide are used in the donor and acceptor phase, respectively. Black-Right-Pointing-Pointer Hollow-fiber pores are continuously fed with toluene placed in the lumen. Black-Right-Pointing-Pointer Mercuric ions can be measured in waters below the {mu}g L{sup -1} level. - Abstract: A three-phase liquid microextraction procedure for the determination of mercury at low concentrations is discussed. To the aqueous sample placed at pH 7 by means of a phosphate buffer, 0.002% (m/v) 1-(2-pyridylazo)-2-naphthol (PAN) is incorporated, and the mixture submitted to microextraction with a hollow-fiber impregnated with toluene and whose lumen contains a 0.05 mol L{sup -1} ammonium iodide solution. The final measurement of the extract is carried out by electrothermal atomic absorption spectrometry (300 Degree-Sign C and 1100 Degree-Sign C for the calcination and atomization temperatures, respectively). The pyrolytic graphite atomizer is coated electrolytically with palladium. An enrichment factor of 270, which results in a 0.06 {mu}g L{sup -1} mercury for the detection limit is obtained. The relative standard deviation at the 1 {mu}g L{sup -1} mercury level is 3.2% (n = 5). The reliability of the procedure is verified by analyzing waters as well as six certified reference materials.

  8. Ammonia-lithium nitrate absorption chiller with an integrated low-pressure compression booster cycle for low driving temperatures

    International Nuclear Information System (INIS)

    Ventas, R.; Lecuona, A.; Zacarias, A.; Venegas, M.

    2010-01-01

    Single-effect absorption refrigeration hybridized with mechanical vapor compression in a vapor circuit is known as the absorption cycle with an integrated booster compressor. In this study, the compressor is located between the evaporator and the absorber. This paper presents a numerical model of this cycle with ammonia-lithium nitrate solution as the working pair. It is based on UA-ΔT lm models for separate regions of plate-type heat exchangers. The results are offered as a function of external circuit flow parameters. Different pressure ratios of the compressor were tested for a wide range of hot water driving temperatures (55-95 deg. C), showing that low values are more beneficial. This cycle allows for working at lower driving temperatures than the single-effect cycle, with low electricity consumption. At the same driving temperature, the capacity is augmented with an increased compressor pressure ratio, thus allowing for demand matching of the cooling. This cycle, operating with hot water at 67 deg. C with a pressure ratio of 2.0, has the capacity of a single-effect absorption cycle at 94 deg. C. The electrical COP was found to be higher than that in an ammonia vapor compression cycle for comprehensive working conditions.

  9. A room-temperature liquid calorimeter prototype for the SSC

    International Nuclear Information System (INIS)

    Brandenburg, G.W.; Geer, S.H.; Oliver, J.; Sadowski, E.; Theriot, D.

    1990-01-01

    Calorimeters will be an extremely important part of SSC detectors as they have been in existing collider detectors. The main issues that need to be addressed are: (1) energy resolution of jets and electrons, (2) segmentation, (3) hermiticity, (4) response time, and (5) radiation resistance. An attractive possibility on all these counts is the use of room-temperature liquids together with uranium, as pioneered by UA1. The authors are planning a prototype calorimeter which consists of a sealed vessel containing both the radiator plates and the readout pads. This geometry has been appropriately named the swimming pool design. The general mechanical starting point is similar to the SLD liquid argon calorimeters. The points they wish to address are the following: (1) Simple and reliable modular construction techniques, (2) Satisfactory electrical connections with minimal geometric impact, (3) The necessity of isolating radiator plates and liquid to maintain purity, (4) What materials can be immersed without compromising the liquid purity. The design and construction of the swimming pool electromagnetic calorimeter prototype is being carried out at the Harvard High Energy Physics Laboratory. This is one of the first attempts to build a full-scale prototype of such a design

  10. Towards spontaneous parametric down-conversion at low temperatures

    Directory of Open Access Journals (Sweden)

    Akatiev Dmitrii

    2017-01-01

    Full Text Available The possibility of observing spontaneous parametric down-conversion in doped nonlinear crystals at low temperatures, which would be useful for combining heralded single-photon sources and quantum memories, is studied theoretically. The ordinary refractive index of a lithium niobate crystal doped with magnesium oxide LiNbO3:MgO is measured at liquid nitrogen and helium temperatures. On the basis of the experimental data, the coefficients of the Sellmeier equation are determined for the temperatures from 5 to 300 K. In addition, a poling period of the nonlinear crystal has been calculated for observing type-0 spontaneous parametric down-conversion (ooo-synchronism at the liquid helium temperature under pumping at the wavelength of λp = 532 nm and emission of the signal field at the wavelength of λs = 794 nm, which corresponds to the resonant absorption line of Tm3+ doped ions.

  11. High-throughput liquid-absorption preconcentrator sampling methods

    Science.gov (United States)

    Zaromb, Solomon

    1994-01-01

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.

  12. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples.

    Science.gov (United States)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-03-03

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 microL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 microgL(-1) with a detection limit of 0.5 microgL(-1). The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 microgL(-1) of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 microgL(-1) ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.

  13. Identifying Liquid-Gas System Misconceptions and Addressing Them Using a Laboratory Exercise on Pressure-Temperature Diagrams of a Mixed Gas Involving Liquid-Vapor Equilibrium

    Science.gov (United States)

    Yoshikawa, Masahiro; Koga, Nobuyoshi

    2016-01-01

    This study focuses on students' understandings of a liquid-gas system with liquid-vapor equilibrium in a closed system using a pressure-temperature ("P-T") diagram. By administrating three assessment questions concerning the "P-T" diagrams of liquid-gas systems to students at the beginning of undergraduate general chemistry…

  14. Intermetallic and electrical insulator coatings on high-temperature alloys in liquid-lithium environments

    International Nuclear Information System (INIS)

    Park, J.H.

    1994-06-01

    In the design of liquid-metal cooling systems for fusion-reactor blanket, applications, the corrosion resistance of structural materials and the magnetohydrodynamic (MHD) force and its subsequent influence on thermal hydraulics and corrosion are major concerns. When the system is cooled by liquid metals, insulator coatings are required on piping surfaces in contact with the coolant. The objective of this study is to develop stable corrosion-resistant electrical insulator coatings at the liquid-metal/structural-material interface, with emphasis on electrically insulating coatings that prevent adverse MHD-generated currents from passing through the structural wall, and Be-V intermetallic coatings for first-wall components that face the plasma. Vanadium and V-base alloys are leading candidate materials for structural applications in a fusion reactor. Various intermetallic films were produced on V-alloys and on Types 304 and 316 stainless steel. The intermetallic layers were developed by exposure of the materials to liquid Li containing 2 at temperatures of 500--1030 degree C. CaO electrical insulator coatings were produced by reaction of the oxygen-rich layer with <5 at. % Ca dissolved in liquid Li at 400--700 degree C. The reaction converted the oxygen-rich layer to an electrically insulating film. This coating method is applicable to reactor components because the liquid metal can be used over and over; only the solute within the liquid metal is consumed. This paper will discuss initial results on the nature of the coatings and their in-situ electrical resistivity characteristics in liquid Li at high temperatures

  15. Microprocessor Based Temperature Control of Liquid Delivery with Flow Disturbances.

    Science.gov (United States)

    Kaya, Azmi

    1982-01-01

    Discusses analytical design and experimental verification of a PID control value for a temperature controlled liquid delivery system, demonstrating that the analytical design techniques can be experimentally verified by using digital controls as a tool. Digital control instrumentation and implementation are also demonstrated and documented for…

  16. Active terahertz metamaterials based on liquid-crystal induced transparency and absorption

    Science.gov (United States)

    Yang, Lei; Fan, Fei; Chen, Meng; Zhang, Xuanzhou; Chang, Sheng-Jiang

    2017-01-01

    An active terahertz (THz) liquid crystal (LC) metamaterial has been experimentally investigated for THz wave modulation. Some interesting phenomena of resonance shifting, tunable electromagnetically induced transparency (EIT) and electromagnetically induced absorption (EIA) have been observed in the same device structure under different DC bias directions and different incident wave polarization directions by the THz time domain spectroscopy. Further theoretical studies indicate that these effects originate from interference and coupling between bright and dark mode components of elliptically polarized modes in the LC metamaterial, which are induced by the optical activity of LC alignment controllable by the electric field as well as the changes of LC refractive index. The LC layer is indeed a phase retarder and polarization converter that is controlled by the DC bias. The THz modulation depth of the analogs of EIT and EIA effects are 18.3 dB and 10.5 dB in their frequency band, respectively. Electrical control, large modulation depth and feasible integration of this LC device make it an ideal candidate for THz tunable filter, intensity modulator and spatial light modulator.

  17. CO concentration and temperature sensor for combustion gases using quantum-cascade laser absorption near 4.7 μm

    KAUST Repository

    Ren, Wei; Farooq, Aamir; Davidson, David Frank; Hanson, Ronald Kenneth

    2012-01-01

    A sensor for sensitive in situ measurements of carbon monoxide and temperature in combustion gases has been developed using absorption transitions in the (v′ = 1 ← v″ = 0) and (v′ = 2 ← v″ = 1) fundamental bands of CO. Recent availability of mid-infrared quantum-cascade (QC) lasers provides convenient access to the CO fundamental band near 4.7 μm, having approximately 104 and 102 times stronger absorption line-strengths compared to the overtone bands near 1.55 μm and 2.3 μm used previously to sense CO in combustion gases. Spectroscopic parameters of the selected transitions were determined via laboratory measurements in a shock tube over the 1100-2000 K range and also at room temperature. A single-laser absorption sensor was developed for accurate CO measurements in shock-heated gases by scanning the line pair v″ = 0, R(12) and v″ = 1, R(21) at 2.5 kHz. To capture the rapidly varying CO time-histories in chemical reactions, two different QC lasers were then used to probe the line-center absorbance of transitions v″ = 0, P(20) and v″ = 1, R(21) with a bandwidth of 1 MHz using fixed-wavelength direct absorption. The sensor was applied in successful shock tube measurements of temperature and CO time-histories during the pyrolysis and oxidation of methyl formate, illustrating the capability of this sensor for chemical kinetic studies. © 2012 Springer-Verlag.

  18. CO concentration and temperature sensor for combustion gases using quantum-cascade laser absorption near 4.7 μm

    KAUST Repository

    Ren, Wei

    2012-05-25

    A sensor for sensitive in situ measurements of carbon monoxide and temperature in combustion gases has been developed using absorption transitions in the (v′ = 1 ← v″ = 0) and (v′ = 2 ← v″ = 1) fundamental bands of CO. Recent availability of mid-infrared quantum-cascade (QC) lasers provides convenient access to the CO fundamental band near 4.7 μm, having approximately 104 and 102 times stronger absorption line-strengths compared to the overtone bands near 1.55 μm and 2.3 μm used previously to sense CO in combustion gases. Spectroscopic parameters of the selected transitions were determined via laboratory measurements in a shock tube over the 1100-2000 K range and also at room temperature. A single-laser absorption sensor was developed for accurate CO measurements in shock-heated gases by scanning the line pair v″ = 0, R(12) and v″ = 1, R(21) at 2.5 kHz. To capture the rapidly varying CO time-histories in chemical reactions, two different QC lasers were then used to probe the line-center absorbance of transitions v″ = 0, P(20) and v″ = 1, R(21) with a bandwidth of 1 MHz using fixed-wavelength direct absorption. The sensor was applied in successful shock tube measurements of temperature and CO time-histories during the pyrolysis and oxidation of methyl formate, illustrating the capability of this sensor for chemical kinetic studies. © 2012 Springer-Verlag.

  19. What happens to liquid helium 3 at very low temperatures

    International Nuclear Information System (INIS)

    Dobbs, E.R.; Bedford Coll., London

    1976-01-01

    Liquid helium 3 forms a highly compressible, quantum fluid of fermions at its boiling point of 3.2 K. As it is cooled this fluid condenses into a viscous Fermi liquid until at temperatures of a few millikelvin it is transformed into one of two superfluids, A or B. The A phase is an anisotoropic superfluid of the Anderson-Brinkman-Morel type, while the B phase is an isotropic superfluid of the Balian-Werthamer type. The properties of these superfluids will be discussed and contrasted with those of superfluid helium 4 and metallic superconductors. (orig.) [de

  20. Method and apparatus for continuous monitoring and control of neutron absorption properties of chemical shim with temperature compensation

    International Nuclear Information System (INIS)

    Schukei, G.E.; Kowles, J.E.

    1975-01-01

    An apparatus is described to continuously monitor and control the neutron absorption properties of chemical shim used in regulating reactivity of a pressurized water nuclear reactor. Coolant-moderator fluid, containing soluble chemical shim with a neutron absorption property is continuously passed through a chamber having at least one neutron detector spaced from a neutron source of known strength. Utilizing the neutron absorptiometery principle, a signal relating to the concentration of the chemical shim in the coolant-moderator is derived. In addition, the temperature of the sample of coolant is obtained and a temperature compensation signal is generated. The signal related to chemical shim concentration is modified by the temperature compensation signal to correct for temperature related effects. The corrected signal is then applied to a readout and alarm device so that constant monitoring of the shim concentration may be accomplished; additionally, the signal may be applied to maintain the concentration of the chemical shim in the coolant-moderator at a desired level. (U.S.)

  1. A New Experimental Design to Study the Kinetics of Solid Dissolution into Liquids at Elevated Temperature

    Science.gov (United States)

    Wang, Huijun; White, Jesse F.; Sichen, Du

    2018-04-01

    A new method was developed to study the dissolution of a solid cylinder in a liquid under forced convection at elevated temperature. In the new design, a rotating cylinder was placed concentrically in a crucible fabricated by boring four holes into a blank material for creating an internal volume with a quatrefoil profile. A strong flow in the radial direction in the liquid was created, which was evidently shown by computational fluid dynamic (CFD) calculations and experiments at both room temperature and elevated temperature. The new setup was able to freeze the sample as it was at experimental temperature, particularly the interface between the solid and the liquid. This freezing was necessary to obtain reliable information for understanding the reaction mechanism. This was exemplified by the study of dissolution of a refractory in liquid slag. The absence of flow in the radial direction in the traditional setup using a symmetrical cylinder was also discussed. The differences in the findings by past investigators using the symmetrical cylinder are most likely due to the extent of misalignment of the cylinder in the containment vessel.

  2. Quantitative liquid and vapor distribution measurements in evaporating fuel sprays using laser-induced exciplex fluorescence

    International Nuclear Information System (INIS)

    Fansler, Todd D; Drake, Michael C; Gajdeczko, Boguslaw; Düwel, Isabell; Koban, Wieland; Zimmermann, Frank P; Schulz, Christof

    2009-01-01

    Fully quantitative two-dimensional measurements of liquid- and vapor-phase fuel distributions (mass per unit volume) from high-pressure direct-injection gasoline injectors are reported for conditions of both slow and rapid vaporization in a heated, high-pressure spray chamber. The measurements employ the coevaporative gasoline-like fluorobenzene (FB)/diethylmethylamine (DEMA)/hexane exciplex tracer/fuel system. In contrast to most previous laser-induced exciplex-fluorescence (LIEF) experiments, the quantitative results here include regions in which liquid and vapor fuel coexist (e.g. near the injector exit). A unique aspect is evaluation of both vapor- and liquid-phase distributions at varying temperature and pressure using only in situ vapor-phase fluorescence calibration measurements at room temperature and atmospheric pressure. This approach draws on recent extensive measurements of the temperature-dependent spectroscopic properties of the FB–DEMA exciplex system, in particular on knowledge of the quantum efficiencies of the vapor-phase and liquid-phase (exciplex) fluorescence. In addition to procedures necessary for quantitative measurements, we discuss corrections for liquid–vapor crosstalk (liquid fluorescence that overlaps the vapor-fluorescence bandpass), the unknown local temperature due to vaporization-induced cooling, and laser-sheet attenuation by scattering and absorption

  3. Measurement of the parameters of non-stationary gas flows by diode laser absorption spectroscopy in case of high temperature and high pressure

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Liger, V.V.; Kuritsyn, Yu.A.; Mironenko, V.R.; Ponurovskii, Ya.Ya.; Kolesnikov, O.M.

    2017-01-01

    Experimental version of diode laser absorption spectrometer (DLAS) for contactless measurements of temperature and water vapor concentration in supersonic gas flows is developed. The spectrometer can be used for the measurements of temperature up to 2500 K and total pressure up to 3 atm. The technique is based on the registration of the transient absorption spectra of a target molecules and fitting of the experimental spectra by the simulated ones constructed using the spectroscopic databases. The temperature is inferred from the ratio of the intensities of the absorption lines with different low energy levels. In gas media with the above parameters the absorption lines are broadened which demands the use of two diode lasers (DL) working in different spectral ranges. The software for selection of the optimal line combinations was developed. The combination of two strong lines in the spectral ranges 1.39 μ and 1.34 μ was selected as the optimal one. The efficiency of the developed technique was exemplified in the first set of the experiments in conditions of real propulsion in Zhukovsky Central Aerohydrodynamic Institute (TsAGI) for the temperatures within 500-2200 K range and total pressure up to 3 atm.

  4. Wave processes in a superfluid liquid

    International Nuclear Information System (INIS)

    Sanikidze, D.G.

    1981-01-01

    The monograph is devoted to theory of sound wave propagation in superfluid He 4 and He 3 -He 4 solutions. Hydrodynamic theory of sound oscillation propagation in superfluid liquid under conditions of confined geometry is given. In particular considered are problems of propagation of the first, second and fourth sounds, dispersion, attenuation and absorption, sound propagation in films, channels and waveguides. The monograph summarizes a certain stage of studying different sound oscillations in superfluid liquid and along with original results contains also results obtained by other investigators. The theory and experimental investigations carried on both in the Soviet Union and abroad are compared. The monograph is intended for specialists working in the area of low temperature physics and for students of the given speciality [ru

  5. Hg⁰ removal from flue gas by ionic liquid/H₂O₂.

    Science.gov (United States)

    Cheng, Guangwen; Bai, Bofeng; Zhang, Qiang; Cai, Ming

    2014-09-15

    1-Alkyl-3-methylimidazolium chloride ionic liquids ([Cnmim] Cl, n=4, 6, 8) were prepared. The ionic liquid was then mixed with hydrogen peroxide (H2O2) to form an absorbent. The Hg(0) removal performance of the absorbent was investigated in a gas/liquid scrubber using simulated flue gas. It was found that the ionic liquid/H2O2 mixture was an excellent absorbent and could be used to remove Hg(0) from flue gas. When the mass ratio of H2O2 to ionic liquid was 0.5, the absorbent showed high Hg(0) removal efficiency (up to 98%). The Hg(0) removal efficiency usually increased with the absorption temperature, while decreased with the increase of alkyl chain length in ionic liquid molecule. The Hg(0) removal mechanism involved with Hg(0) oxidation by H2O2 and Hg(2+) transfer from aqueous phase to ionic liquid phase. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Base profile design for high-performance operation of bipolar transistors at liquid-nitrogen temperature

    International Nuclear Information System (INIS)

    Stork, J.M.C.; Harame, D.L.; Meyerson, B.S.; Nguyen, T.N.

    1989-01-01

    The base profile requirements of Si bipolar junction transistors (BJT's) high-performance operation at liquid-nitrogen temperature are examined. Measurements of thin epitaxial-base polysilicon-emitter n-p-n transistors with increasing base doping show the effects of bandgap narrowing, mobility changes, and carrier freezeout. At room temperature the collector current at low injection is proportional to the integrated base charge, independent of the impurity distribution. At temperatures below 150 Κ, however, minority injection is dominated by the peak base doping because of the greater effectiveness of bandgap narrowing. When the peak doping in the base approaches 10 19 cm -3 , the bandgap difference between emitter and base is sufficiently small that the current gain no longer monotonically decreases with lower temperature but instead shows a maximum as low as 180 Κ. The device design window appears limited at the low-current end by increased base-emitter leakage due to tunneling and by resistance control at the high-current end. Using the measured dc characteristics, circuit delay calculations are made to estimate the performance of an ECL ring oscillator at room and liquid-nitrogen temperatures. It is shown that if the base doping can be raised to 10 19 cm -3 while keeping the base thickness constant, the minimum delay at liquid nitrogen can approach the delay of optimized devices at room temperature

  7. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  8. Room-temperature ionic liquids and composite materials: platform technologies for CO(2) capture.

    Science.gov (United States)

    Bara, Jason E; Camper, Dean E; Gin, Douglas L; Noble, Richard D

    2010-01-19

    Clean energy production has become one of the most prominent global issues of the early 21st century, prompting social, economic, and scientific debates regarding energy usage, energy sources, and sustainable energy strategies. The reduction of greenhouse gas emissions, specifically carbon dioxide (CO(2)), figures prominently in the discussions on the future of global energy policy. Billions of tons of annual CO(2) emissions are the direct result of fossil fuel combustion to generate electricity. Producing clean energy from abundant sources such as coal will require a massive infrastructure and highly efficient capture technologies to curb CO(2) emissions. Current technologies for CO(2) removal from other gases, such as those used in natural gas sweetening, are also capable of capturing CO(2) from power plant emissions. Aqueous amine processes are found in the vast majority of natural gas sweetening operations in the United States. However, conventional aqueous amine processes are highly energy intensive; their implementation for postcombustion CO(2) capture from power plant emissions would drastically cut plant output and efficiency. Membranes, another technology used in natural gas sweetening, have been proposed as an alternative mechanism for CO(2) capture from flue gas. Although membranes offer a potentially less energy-intensive approach, their development and industrial implementation lags far behind that of amine processes. Thus, to minimize the impact of postcombustion CO(2) capture on the economics of energy production, advances are needed in both of these areas. In this Account, we review our recent research devoted to absorptive processes and membranes. Specifically, we have explored the use of room-temperature ionic liquids (RTILs) in absorptive and membrane technologies for CO(2) capture. RTILs present a highly versatile and tunable platform for the development of new processes and materials aimed at the capture of CO(2) from power plant flue gas and

  9. Tanker for the transport of very low temperature liquids at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Messer, E S

    1968-02-08

    This tanker for the transport of very low temperature liquids, especially liquefied methane or natural gas, has a large capacity reservoir insulated on the outside. A second reservoir in the bottom of the hull, below the main reservoir, collects liquid leaking out from the main reservoir and is equipped with a drain pipe. The pipe serving to fill and to empty the main reservoir passes through this second reservoir. (4 claims)

  10. Motions in a viscous inorganic liquid: ferrous ion in cold phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Flinn, P A [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA); Zabransky, B J; Ruby, S L [Argonne National Lab., Ill. (USA)

    1976-01-01

    The two main purposes of this work were to decide if there are rotational relaxation effects when diffusion becomes important above the glass transition temperature T/sub g/; and if the intensity of the Moessbauer absorption can be understood in terms of glass and liquid dynamics. Rotational relaxation was not seen, and there is a rapid increase in soft modes with temperature beginning at T/sub g/ seen both by Moessbauer technique and by Raman scattering.

  11. (Liquid + liquid) equilibrium of (NaNO{sub 3} + PEG 4000 + H{sub 2}O) ternary system at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, Yecid P. [Departamento de Ingenieria Quimica, Universidad de Antofagasta, CICITEM (Chile); Galleguillos, Hector R., E-mail: hgalleguillos@uantof.cl [Departamento de Ingenieria Quimica, Universidad de Antofagasta, CICITEM (Chile)

    2011-11-15

    Highlights: > LLE data for the ATPS NaNO{sub 3} + PEG 4000 were determined at T = (288.15 and 308.15) K. > The experimental data shown that the temperature increases as STL and biphasic area increase. > The Chen-NRTL, modified Wilson and UNIQUAC models were used to correlate the experimental tie-line data. > The results show that the quality of fitting is better with the UNIQUAC model. - Abstract: Phase diagram and (liquid + liquid) equilibrium (LLE) data for the (NaNO{sub 3} + polyethylene glycol 4000 (PEG 4000) + H{sub 2}O) system have been determined experimentally at T = (288.15 and 308.15) K. The effects of temperature on the binodal curves and tie-lines have been studied and it was found that an increasing in temperature caused the expansion of two-phase region. The Chen-NRTL, modified Wilson and UNIQUAC models were used to correlate the experimental tie-line data. The results show that the quality of fitting is better with the UNIQUAC model.

  12. The accommodation coefficient of the liquid at temperatures below the boiling

    Directory of Open Access Journals (Sweden)

    Bulba Elena E.

    2015-01-01

    Full Text Available Are carried out experimental investigation of the laws of vaporization at temperatures below the boiling point. Is determined the mass rate of evaporation of distilled water in large intervals of time at different temperatures in order to sound conclusions about the stationarity of the process of evaporation of the liquid in the conditions of the experiments performed, and also studied the effect of temperature on the rate of evaporation. Accommodation coefficient is defined in the mathematical expression of the law of Hertz-Knudsen for standart substance used in the experiments.

  13. Transport and spectroscopic studies of liquid and polymer electrolytes

    Science.gov (United States)

    Bopege, Dharshani Nimali

    Liquid and polymer electrolytes are interesting and important materials to study as they are used in Li rechargeable batteries and other electrochemical devices. It is essential to investigate the fundamental properties of electrolytes such as ionic conductivity, diffusion, and ionic association to enhance battery performance in different battery markets. This dissertation mainly focuses on the temperature-dependent charge and mass transport processes and ionic association of different electrolyte systems. Impedance spectroscopy and pulsed field gradient nuclear magnetic resonance spectroscopy were used to measure the ionic conductivity and diffusion coefficients of ketone and acetate based liquid electrolytes. In this study, charge and mass transport in non-aqueous liquid electrolytes have been viewed from an entirely different perspective by introducing the compensated Arrhenius formalism. Here, the conductivity and diffusion coefficient are written as an Arrhenius-like expression with a temperature-dependent static dielectric constant dependence in the exponential prefactor. The compensated Arrhenius formalism reported in this dissertation very accurately describes temperature-dependent conductivity data for acetate and ketone-based electrolytes as well as temperature-dependent diffusion data of pure solvents. We found that calculated average activation energies of ketone-based electrolytes are close to each other for both conductivity and diffusion data (in the range 24-26 kJ/mol). Also, this study shows that average activation energies of acetate-based electrolytes are higher than those for the ketone systems (in the range 33-37 kJ/mol). Further, we observed higher dielectric constants and ionic conductivities for both dilute and concentrated ketone solutions with temperature. Vibrational spectroscopy (Infrared and Raman) was used to probe intermolecular interactions in both polymer and liquid electrolytes, particularly those which contain lithium

  14. On the critical temperature, normal boiling point, and vapor pressure of ionic liquids.

    Science.gov (United States)

    Rebelo, Luis P N; Canongia Lopes, José N; Esperança, José M S S; Filipe, Eduardo

    2005-04-07

    One-stage, reduced-pressure distillations at moderate temperature of 1-decyl- and 1-dodecyl-3-methylimidazolium bistriflilamide ([Ntf(2)](-)) ionic liquids (ILs) have been performed. These liquid-vapor equilibria can be understood in light of predictions for normal boiling points of ILs. The predictions are based on experimental surface tension and density data, which are used to estimate the critical points of several ILs and their corresponding normal boiling temperatures. In contrast to the situation found for relatively unstable ILs at high-temperature such as those containing [BF(4)](-) or [PF(6)](-) anions, [Ntf(2)](-)-based ILs constitute a promising class in which reliable, accurate vapor pressure measurements can in principle be performed. This property is paramount for assisting in the development and testing of accurate molecular models.

  15. Pulse radiolysis study on solvated electrons in ionic liquid with controlling water content

    International Nuclear Information System (INIS)

    Yang Jinfeng; Kondoh, T.; Yoshida, Y.; Nagaishi, R.

    2006-01-01

    Room-temperature ionic liquids, which are nonvolatile and nonflammable, have been proposed as 'green solvents' for new applications in chemical synthesis, separation chemistry, electrochemistry and other areas. In the separation chemistry, the hydrophobic ionic liquids have been practically expected to be alternative to traditional organic solvents for solvent extraction of 4f and 5f elements from the viewpoints of the immiscibility in water, especially in the spent nuclear fuel reprocessing. However, the chemical reaction or kinetics studies are important to apply the ionic liquids for various processes. To understand the effects of ionic liquids on chemical reactions, pulse radiolysis studies of ionic liquid have been carried out on nanosecond scale by using a 27 MeV electron beam and an analyzing light source of xenon lamp. In the experiment, a hydrophobic ionic liquid of diethylmethyl(2-methoxy)ammonium-bis(trifluoromethanesulfonyl)imide (DEMMA-TFSI) salt was used. The ionic liquid of DEMMA-TFSI was prepared by reacting equimolar amounts of diethylmethyl(2-methoxy)ammonium chloride (C 10 H 20 F 6 N 2 O 5 S 2 Cl, >98%, Nisshinbo) with lithium bis(trifluoromethanesulfonyl)imide (LiN(SO 2 CF 3 ) 2 , SynQuest Labs., Inc.) in aqueous solutions at room temperature. The ionic liquid was separated from the aqueous phase, purified by repeated extractions with water to LiCl and excess reagent, and finally dried at 110 degree C under vacuum. The transient absorptions of the ionic liquid were measured at wavelengths from 350 to 1400 nm, in which two photodiodes of silicon ( 1000 nm) were used. The spectrum of solvated electrons in the ionic liquid of DEMMA-TFSI was obtained with an absorption peak of 1060 nm and a wide bandwidth of about 600 nm (FWHM). The decay constant of the solvated electrons in the ionic liquid was 1.54 x 10 7 s -1 , which is independent on the wavelength. The absorption peak of the spectrum was blue-shifted from 1060 to 780 nm with increasing water

  16. A reactor/receiver-concept for liquid-phase high-temperature processes

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt-Traub, H.; Hahm, T. [Dortmund Univ. (Germany). Dept. of Chemical Engineering

    1997-12-31

    Besides the conversion of solar light to electricity solar energy can be used directly in photo- and thermochemistry. In the temperature range from 1000 to 2000 K there is a high demand for industrial process heat offering a variety of possibilities for solar thermal applications. Especially in the field of liquid-phase high-temperature processes there are hardly no solar thermal applications which exceed the stage of laboratory experiments. It was therefore the aim of two projects financed by the AG Solar of North Rhine-Westphalia, Germany, to develop concepts for commercial scale solar thermal plants and to judge them economically and ecologically. Some general problems have to be overcome to realize a commercial scale solar thermal plant for liquid-phase processes. The concept developed consists of a heliostat field, a tower reflector and an open receiver with a closed reaction chamber. The feasibility of a solar thermal plant for high-temperature liquid-phase processes has been shown in principle. The projected plant consists of a 4400 m{sup 2} heliostat field, a tower plus reflecting mirrors with a total area of 220 m{sup 2} and an open receiver with a closed annular reaction zone. For temperatures below 1700 K the overall efficiency is high enough to yield energetic amortization times of less than 1 year. For a further improvement and a verification of the calculation a closer look at the reactor/receiver and its heat transfer processes is necessary. This is done by using a mixed strategy of experiments and simulation. First experiments were carried out with a semitransparent salt and an opaque metal. The first stage of the experiments will end during the next weeks and their results have to be compared with the simulation. The simulation will then be extended to transparent melts. The second stage of the experiments which include the reaction chamber will start in 1997. An improvement of the reactor might be achieved using nonimaging concentrators to further

  17. Fructose decomposition kinetics in organic acids-enriched high temperature liquid water

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yinghua; Lu, Xiuyang; Yuan, Lei; Liu, Xin [Department of Chemical and Biochemical Engineering, Zhejiang University, Zheda Road 38, Hangzhou 310027, Zhejiang (China)

    2009-09-15

    Biomass continues to be an important candidate as a renewable resource for energy, chemicals, and feedstock. Decomposition of biomass in high temperature liquid water is a promising technique for producing industrially important chemicals such as 5-hydroxymethylfurfural (5-HMF), furfural, levulinic acid with high efficiency. Hexose, which is the hydrolysis product of cellulose, will be one of the most important starting chemicals in the coming society that is highly dependent on biomass. Taking fructose as a model compound, its decomposition kinetics in organic acids-enriched high temperature liquid water was studied in the temperature range from 180 C to 220 C under the pressure of 10 MPa to further improve reaction rate and selectivity of the decomposition reactions. The results showed that the reaction rate is greatly enhanced with the addition of organic acids, especially formic acid. The effects of temperature, residence time, organic acids and their concentrations on the conversion of fructose and yield of 5-HMF were investigated. The evaluated apparent activation energies of fructose decomposition are 126.8 {+-} 3.3 kJ mol{sup -1} without any catalyst, 112.0 {+-} 13.7 kJ mol{sup -1} catalyzed with formic acid, and 125.6 {+-} 3.8 kJ mol{sup -1} catalyzed with acetic acid, respectively, which shows no significant difference. (author)

  18. A dispersive liquid--liquid microextraction methodology for copper (II) in environmental samples prior to determination using microsample injection flame atomic absorption spectrometry.

    Science.gov (United States)

    Alothman, Zeid A; Habila, Mohamed; Yilmaz, Erkan; Soylak, Mustafa

    2013-01-01

    A simple, environmentally friendly, and efficient dispersive liquid-liquid microextraction method combined with microsample injection flame atomic absorption spectrometry was developed for the separation and preconcentration of Cu(II). 2-(5-Bromo-2-pyridylazo)-5-(diethylamino)phenol (5-Br-PADAP) was used to form a hydrophobic complex of Cu(II) ions in the aqueous phase before extraction. To extract the Cu(II)-5-Br-PADAP complex from the aqueous phase to the organic phase, 2.0 mL of acetone as a disperser solvent and 200 microL of chloroform as an extraction solvent were used. The influences of important analytical parameters, such as the pH, types and volumes of the extraction and disperser solvents, amount of chelating agent, sample volume, and matrix effects, on the microextraction procedure were evaluated and optimized. Using the optimal conditions, the LOD, LOQ, preconcentration factor, and RSD were determined to be 1.4 microg/L, 4.7 microg/L, 120, and 6.5%, respectively. The accuracy of the proposed method was investigated using standard addition/recovery tests. The analysis of certified reference materials produced satisfactory analytical results. The developed method was applied for the determination of Cu in real samples.

  19. Absorbent material for type a radioactive materials packaging containing liquids

    International Nuclear Information System (INIS)

    Saunders, G.A.

    1989-11-01

    The application of absorbent materials to the packaging and transport of liquid radioactive materials in Type A packages has not been reported in the literature. However, a significant body of research exists on absorbent materials for personal hygiene products such as diapers. Absorption capacity is dependent on both the absorbent material and the liquid being absorbed. Theoretical principles for capillary absorption in both the horizontal and the vertical plane indicate that small contact angle between the absorbent fibre and the liquid, and a small inter-fibre pore size are important. Some fluid parameters such as viscosity affect the rate of absorption but not the final absorption capacity. There appears to be little comparability between results obtained for the same absorbent and fluid using different test procedures. Test samples of materials from several classes of potential absorbents have been evaluated in this study, and shown to have a wide range of absorbent capacities. Foams, natural fibres, artificial fibres and granular materials are all potentially useful absorbents, with capacities ranging from as little as 0.86 to as much as 40.6 grams of distilled water per gram of absorbent. Two experimental procedures for evaluating the absorbent capacity of these materials have been detailed in this report, and found suitable for evaluating granular, fibrous or foam materials. Compression of the absorbent material reduces its capacity, but parameters such as relative humidity, pH, temperature, and viscosity appear to have little significant influence on capacity. When the materials were loaded to 50% of their one-minute absorbency, subsequent loss of the absorbed liquid was generally minimal. All of the absorbent materials rapidly lost their absorbed water through evaporation within twenty-four hours in still air at 21 degrees C and 50% relative humidity

  20. Test of Topmetal-II{sup −} in liquid nitrogen for cryogenic temperature TPCs

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Shuguang; Fan, Yan; An, Mangmang; Chen, Chufeng; Huang, Guangming; Liu, Jun; Pei, Hua; Sun, Xiangming, E-mail: xmsun@phy.ccnu.edu.cn; Yang, Ping; Wang, Dong; Xiao, Le; Wang, Zhen; Wang, Kai; Zhou, Wei

    2016-09-11

    Topmetal-II{sup −} is a highly pixelated direct charge sensor that contains a 72×72 pixel array of 83 μm pitch size. The key feature of Topmetal-II{sup −} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. Topmetal-II{sup −} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a Topmetal-II{sup −} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that Topmetal-II{sup −} can also operate well at this low temperature with a noise (ENC) of 12 e{sup −} lower than that at room temperature (13 e{sup −}). From the noise perspective, Topmetal-II{sup −} is a promising candidate for the next generation readout of liquid argon and xenon time projection chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.

  1. Anomalous temperature dependence of layer spacing of de Vries liquid crystals: Compensation model

    Energy Technology Data Exchange (ETDEWEB)

    Merkel, K. [Central Mining Institute, Katowice 40-166 (Poland); Kocot, A. [Institute of Physics, Silesian University, Katowice 40-007 (Poland); Vij, J. K., E-mail: jvij@tcd.ie [Department of Electronic and Electrical Engineering, Trinity College, The University of Dublin, Dublin 2 (Ireland); Stevenson, P. J.; Panov, A.; Rodriguez, D. [School of Chemistry and Chemical Engineering, Queens University Belfast, Belfast BT7 1NN, Northern Ireland (United Kingdom)

    2016-06-13

    Smectic liquid crystals that exhibit temperature independent layer thickness offer technological advantages for their use in displays and photonic devices. The dependence of the layer spacing in SmA and SmC phases of de Vries liquid crystals is found to exhibit distinct features. On entering the SmC phase, the layer thickness initially decreases below SmA to SmC (T{sub A–C}) transition temperature but increases anomalously with reducing temperature despite the molecular tilt increasing. This anomalous observation is being explained quantitatively. Results of IR spectroscopy show that layer shrinkage is caused by tilt of the mesogen's rigid core, whereas the expansion is caused by the chains getting more ordered with reducing temperature. This mutual compensation arising from molecular fragments contributing to the layer thickness differs from the previous models. The orientational order parameter of the rigid core of the mesogen provides direct evidence for de Vries cone model in the SmA phase for the two compounds investigated.

  2. Effect of oils on drug absorption

    OpenAIRE

    Palin, K.J.

    1981-01-01

    Oil and emulsion vehicles have been shown to alter the oral absorption of many drugs. This may be due to enhanced lymph flow and/or altered gastro-intestinal motility in the presence of the oils. The oral absorption of a model compound (DOT) in the presence of three chemically different oils, arachis oil, Miglyol 812 and liquid paraffin was investigated in rats, the influence of lymphatic absorption and gastro-intestinal motility being determined. The findings were applied to the for.mulation...

  3. Forced convection of ammonia. Liquid ammonia. Case of large wall to fluid temperature differences; Convection forcee de l'ammoniac. Premiere partie. Ammoniac liquide. Cas de grands ecarts de temperatures entre fluide et paroi

    Energy Technology Data Exchange (ETDEWEB)

    Perroud, P; Rebiere, J; Rowe, A [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1967-07-01

    Two test tubes were used: Inconel (ID 3 mm, OD 3.5 mn length 300 mm) and tantalum (ID 3 mm, OD 4 mm; length 450 mm). Measurements were performed in the following conditions inlet temperature of subcooled liquid from +4 deg C to + 54 deg C; inlet pressure from 10 to 42, bars; mass velocity from 33 to 243 g/cm{sup 2}.s; maximum heat flux 583 W/cm{sup 2}; maximum wall temperature 1523 deg C; steam quality reaching 1. When the flow is liquid, a film of vapor is formed on the heated wall. Using the Martinelli-Nelson parameter X{sub tt} a correlation of the heat transfer coefficients is presented in the two-phase region. This correlation is analogous to the one developed for liquid hydrogen. In the gaseous phase region the correlation established is: N{sub u} 0.0046 R{sub e}{sup 0.95} P{sub r}{sup 0.4} with a film temperature of t{sub 0.5}. The Martinelli-Nelson method gives fairly good results for pressure drop evaluation. Gross experimental results are published separately. (authors) [French] Deux tubes d'essais ont ete utilises: inconel (diametre 3 x 3,5 mm; longueur 300 mm) et tantale (diametre 3 x 4 mm; longueur 450 mm). Les mesures ont ete effectuees dans les conditions suivantes: temperature d'entree du liquide sous-refroidi, + 4 deg C a + 54 deg C; pression d'entree, 10 a 42 bars; vitesse massique, 33 a 243 g/cm{sup 2}.s; densite de flux de chaleur maximum 583 W/cm{sup 2}; temperature maximale de la paroi: 1523 deg C; titre de vapeur atteignant 1. Quand l'ecoulement est liquide, il se forme un film de vapeur sur la paroi. En double-phase on a etabli une correlation des coefficients d'echanges, utilisant le parametre de Martinelli et Nelson X{sub tt}, analogue a celle obtenue pour l'hydrogene liquide. En phase gazeuse la correlation presentee est: N{sub u} = 0,0046 R{sub e}{sup 0,95} P{sub r}{sup 0,4} avec une temperature de film de t{sub 0,5}. La methode de Martinelli et Nelson donne d'assez bons resultats pour le calcul des pertes de charge. Les resultats

  4. Gallium-Based Room-Temperature Liquid Metals: Actuation and Manipulation of Droplets and Flows

    Directory of Open Access Journals (Sweden)

    Leily Majidi

    2017-08-01

    Full Text Available Gallium-based room-temperature liquid metals possess extremely valuable properties, such as low toxicity, low vapor pressure, and high thermal and electrical conductivity enabling them to become suitable substitutes for mercury and beyond in wide range of applications. When exposed to air, a native oxide layer forms on the surface of gallium-based liquid metals which mechanically stabilizes the liquid. By removing or reconstructing the oxide skin, shape and state of liquid metal droplets and flows can be manipulated/actuated desirably. This can occur manually or in the presence/absence of a magnetic/electric field. These methods lead to numerous useful applications such as soft electronics, reconfigurable devices, and soft robots. In this mini-review, we summarize the most recent progresses achieved on liquid metal droplet generation and actuation of gallium-based liquid metals with/without an external force.

  5. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. RAPID AND SENSITIVE DETERMINATION OF PALLADIUM USING HOMOGENEOUS LIQUID-LIQUID MICROEXTRACTION VIA FLOTATION ASSISTANCE FOLLOWED BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Mohammad Rezaee

    2015-05-01

    Full Text Available A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA followed by graphite furnace atomic absorption spectrometry (GFAAS. Ammonium pyrrolidine dithiocarbamate (APDC was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.

  7. Levitation apparatus for neutron diffraction investigations on high temperature liquids

    International Nuclear Information System (INIS)

    Hennet, Louis; Pozdnyakova, Irina; Bytchkov, Aleksei; Cristiglio, Viviana; Palleau, Pierre; Fischer, Henry E.; Cuello, Gabriel J.; Johnson, Mark; Melin, Philippe; Zanghi, Didier; Brassamin, Severine; Brun, Jean-Francois; Price, David L.; Saboungi, Marie-Louise

    2006-01-01

    We describe a new high temperature environment based on aerodynamic levitation and laser heating designed for neutron scattering experiments up to 3000 deg. C. The sample is heated to the desired temperature with three CO 2 lasers from different directions in order to obtain a homogeneous temperature distribution. The apparent temperature of the sample is measured with an optical pyrometer, and two video cameras are employed to monitor the sample behavior during heating. The levitation setup is enclosed in a vacuum-tight chamber, enabling a high degree of gas purity and a reproducible sample environment for structural investigations on both oxide and metallic melts. High-quality neutron diffraction data have been obtained on liquid Y 3 Al 5 O 12 and ZrNi alloy for relatively short counting times (1.5 h)

  8. Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH{sub 3}/H{sub 2}O Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Young; Kim, Min Sung; Baik, Young Jin; Park, Seong Ryong; Chang, Ki Chang; Ra, Ho Sang [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Kim, Yong Chan [Korea University, Seoul (Korea, Republic of)

    2011-03-15

    This research aims to develop a compression/absorption hybrid heat pump system using an NH{sub 3}/H{sub 2}O as working fluid. The heat pump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a de superheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above 90 .deg. C using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangement of the plate heat exchangers with regard to the concentration and distribution at the inlet of the absorber.

  9. A Novel Temperature Measurement Approach for a High Pressure Dielectric Barrier Discharge Using Diode Laser Absorption Spectroscopy (Preprint)

    National Research Council Canada - National Science Library

    Leiweke, R. J; Ganguly, B. N

    2006-01-01

    A tunable diode laser absorption spectroscopic technique is used to measure both electronically excited state production efficiency and gas temperature rise in a dielectric barrier discharge in argon...

  10. Evaluation and Modeling of Vapor-Liquid Equilibrium and CO2 Absorption Enthalpies of Aqueous Designer Diamines for Post Combustion Capture Processes.

    Science.gov (United States)

    Luo, Weiliang; Yang, Qi; Conway, William; Puxty, Graeme; Feron, Paul; Chen, Jian

    2017-06-20

    Novel absorbents with improved characteristics are required to reduce the existing cost and environmental barriers to deployment of large scale CO 2 capture. Recently, bespoke absorbent molecules have been specifically designed for CO 2 capture applications, and their fundamental properties and suitability for CO 2 capture processes evaluated. From the study, two unique diamine molecules, 4-(2-hydroxyethylamino)piperidine (A4) and 1-(2-hydroxyethyl)-4-aminopiperidine (C4), were selected for further evaluation including thermodynamic characterization. The solubilities of CO 2 in two diamine solutions with a mass fraction of 15% and 30% were measured at different temperatures (313.15-393.15 K) and CO 2 partial pressures (up to 400 kPa) by thermostatic vapor-liquid equilibrium (VLE) stirred cell. The absorption enthalpies of reactions between diamines and CO 2 were evaluated at different temperatures (313.15 and 333.15 K) using a CPA201 reaction calorimeter. The amine protonation constants and associated protonation enthalpies were determined by potentiometric titration. The interaction of CO 2 with the diamine solutions was summarized and a simple mathematical model established that could make a preliminary but good prediction of the VLE and thermodynamic properties. Based on the analyses in this work, the two designer diamines A4 and C4 showed superior performance compared to amines typically used for CO 2 capture and further research will be completed at larger scale.

  11. Actinide, lanthanide and fission product speciation and electrochemistry in high and low temperature ionic melts

    Energy Technology Data Exchange (ETDEWEB)

    Bhatt, Anand I.; Kinoshita, Hajime; Koster, Anne L.; May, Iain; Sharrad, Clint A.; Volkovich, Vladimir A.; Fox, O. Danny; Jones, Chris J.; Lewin, Bob G.; Charnock, John M.; Hennig, Christoph

    2004-07-01

    There is currently a great deal of research interest in the development of molten salt technology, both classical high temperature melts and low temperature ionic liquids, for the electrochemical separation of the actinides from spent nuclear fuel. We are interested in gaining a better understanding of actinide and key fission product speciation and electrochemical properties in a range of melts. Our studies in high temperature alkali metal melts (including LiCl and LiCl-KCl and CsCl-NaCl eutectics) have focussed on in-situ species of U, Th, Tc and Ru using X-ray absorption spectroscopy (XAS, both EXAFS and XANES) and electronic absorption spectroscopy (EAS). We report unusual actinide speciation in high temperature melts and an evaluation of the likelihood of Ru or Tc volatilization during plant operation. Our studies in lower temperature melts (ionic liquids) have focussed on salts containing tertiary alkyl group 15 cations and the bis(tri-fluor-methyl)sulfonyl)imide anion, melts which we have shown to have exceptionally wide electrochemical windows. We report Ln, Th, U and Np speciation (XAS, EAS and vibrational spectroscopy) and electrochemistry in these melts and relate the solution studies to crystallographic characterised benchmark species. (authors)

  12. Actinide, lanthanide and fission product speciation and electrochemistry in high and low temperature ionic melts

    International Nuclear Information System (INIS)

    Bhatt, Anand I.; Kinoshita, Hajime; Koster, Anne L.; May, Iain; Sharrad, Clint A.; Volkovich, Vladimir A.; Fox, O. Danny; Jones, Chris J.; Lewin, Bob G.; Charnock, John M.; Hennig, Christoph

    2004-01-01

    There is currently a great deal of research interest in the development of molten salt technology, both classical high temperature melts and low temperature ionic liquids, for the electrochemical separation of the actinides from spent nuclear fuel. We are interested in gaining a better understanding of actinide and key fission product speciation and electrochemical properties in a range of melts. Our studies in high temperature alkali metal melts (including LiCl and LiCl-KCl and CsCl-NaCl eutectics) have focussed on in-situ species of U, Th, Tc and Ru using X-ray absorption spectroscopy (XAS, both EXAFS and XANES) and electronic absorption spectroscopy (EAS). We report unusual actinide speciation in high temperature melts and an evaluation of the likelihood of Ru or Tc volatilization during plant operation. Our studies in lower temperature melts (ionic liquids) have focussed on salts containing tertiary alkyl group 15 cations and the bis(tri-fluor-methyl)sulfonyl)imide anion, melts which we have shown to have exceptionally wide electrochemical windows. We report Ln, Th, U and Np speciation (XAS, EAS and vibrational spectroscopy) and electrochemistry in these melts and relate the solution studies to crystallographic characterised benchmark species. (authors)

  13. Transition Temperatures of Thermotropic Liquid Crystals from the Local Binary Gray Level Cooccurrence Matrix

    Directory of Open Access Journals (Sweden)

    S. Sreehari Sastry

    2012-01-01

    Full Text Available This paper presents a method which combines the statistical analysis with texture structural analysis called Local Binary Gray Level Cooccurrence Matrix (LBGLCM to investigate the phase transition temperatures of thermotropic p,n-alkyloxy benzoic acid (nOBA, n=4,6,8,10 and 12 liquid crystals. Textures of the homeotropically aligned liquid crystal compounds are recorded as a function of temperature using polarizing optical microscope attached to the hot stage and high resolution camera. In this method, second-order statistical parameters (contrast, energy, homogeneity, and correlation are extracted from the LBGLCM of the textures. The changes associatedwiththe values of extracted parameters as a function of temperature are a helpful process to identify the phases and phase transition temperatures of the samples. Results obtained from this method have validity and are in good agreement with the literature.

  14. Temperature-dependent absorption cross-section measurements of 1-butene (1-C4H8) in VUV and IR

    KAUST Repository

    Es-sebbar, Et-touhami

    2013-01-01

    Vacuum ultraviolet (VUV) and infrared (IR) absorption cross-section measurements of 1-butene (1-C4H8; CH2=CHCH2CH3; Butylene) are reported over the temperature range of 296-529K. The VUV measurements are performed between 115 and 205nm using synchrotron radiation as a tunable VUV light source. Fourier Transform Infrared (FTIR) spectroscopy is employed to measure absorption cross-section and band strengths in the IR region between 1.54 and 25μm (~6500-400cm-1). The measured room-temperature VUV and IR absorption cross-sections are compared with available literature data and are found to be in good agreement. The oscillator strength for the electronic transition (A1A\\'→X1A\\') around 150-205nm is determined to be 0.32±0.01.The gas temperature has a strong effect on both VUV and IR spectra. Measurements made in the VUV region show that the peak value of the band cross-section decreases and the background continuum increases with increasing gas temperature. This behavior is due to a change in the rotational and vibrational population distribution of 1-butene molecule. Similar changes in rotational population are observed in the IR spectra. Moreover, variation of the IR spectra with temperature is used to measure the enthalpy difference between syn and skew conformations of 1-butene and is found to be 0.24±0.03. kcal/mol, which is in excellent agreement with values reported in the literature. The measurements reported in this work will provide the much-needed spectroscopic information for the development of high-temperature quantitative diagnostics in combustion applications and validation of atmospheric chemistry models of extra-solar planets. © 2012 Elsevier Ltd.

  15. A temperature-controlled cell for X-ray study of liquid systems using a commercial DRON-UM1 diffractometer

    International Nuclear Information System (INIS)

    Petrun'kin, S.P.; Garavina, E.V.; Trostin, V.N.

    1995-01-01

    A container (cell) and a temperature-control system have been designed enabling one to carry out x-ray diffraction study of liquid samples both at a fixed temperature and within a certain temperature range using a commercial DRON-UMl x-ray diffractometer. Special features of the cell and the materials used for it allow one to study both chemically inert and corrosive liquids

  16. Absorption of Flue-Gas Components by Ionic Liquids

    DEFF Research Database (Denmark)

    Kolding, Helene; Thomassen, Peter Langelund; Mossin, Susanne

    2014-01-01

    Gas separation by ionic liquids (ILs) is a promising new research field with several potential applications of industrial interest. Thus cleaning of industrial off gases seems to be attractive by use of ILs and Supported Ionic Liquid Phase (SILP) materials. The potential of selected ILs...

  17. A system for traceable measurement of the microwave complex permittivity of liquids at high pressures and temperatures

    International Nuclear Information System (INIS)

    Dimitrakis, G A; Robinson, J; Kingman, S; Lester, E; George, M; Poliakoff, M; Harrison, I; Gregory, A P; Lees, K

    2009-01-01

    A system has been developed for direct traceable dielectric measurements on liquids at high pressures and temperatures. The system consists of a coaxial reflectometric sensor terminated by a metallic cylindrical cell to contain the liquid. It has been designed for measurements on supercritical liquids, but as a first step measurements on dielectric reference liquids were performed. This paper reports on a full evaluation of the system up to 2.5 GHz using methanol, ethanol and n-propanol at pressures up to 9 MPa and temperatures up to 273 °C. A comprehensive approach to the evaluation of uncertainties using Monte Carlo modelling is used

  18. Reaction of hydroxyl radicals with ammonia in liquid water at elevated temperatures

    DEFF Research Database (Denmark)

    Hickel, B.; Sehested, K.

    1992-01-01

    The reaction of hydroxyl radical with ammonia in aqueous solutions has been studied by pulse radiolysis in the temperature range 20-200-degrees-C. The rate constant of the reaction was determined by monitoring the decay of the OH radical absorption at 260 nm for different concentrations of ammonia....... At room temperature the rate constant is (9.7 +/- 1) x 10(7) dm3 mol-1 s-1. In the whole range of temperatures the Tate constant follows Arrhenius law with an activation energy of (5.7 +/- 1) kJ mol-1. The protective effect of dissolved hydrogen on the radiolytic decomposition of ammon a is discussed....

  19. Facile synthesis of iron oxides/reduced graphene oxide composites: application for electromagnetic wave absorption at high temperature.

    Science.gov (United States)

    Zhang, Lili; Yu, Xinxin; Hu, Hongrui; Li, Yang; Wu, Mingzai; Wang, Zhongzhu; Li, Guang; Sun, Zhaoqi; Chen, Changle

    2015-03-19

    Iron oxides/reduced graphene oxide composites were synthesized by facile thermochemical reactions of graphite oxide and FeSO4 · 7H2O. By adjusting reaction temperature, α-Fe2O3/reduced graphene oxide and Fe3O4/reduced graphene oxide composites can be obtained conveniently. Graphene oxide and reduced graphene oxide sheets were demonstrated to regulate the phase transition from α-Fe2O3 to Fe3O4 via γ-Fe2O3, which was reported for the first time. The hydroxyl groups attached on the graphene oxide sheets and H2 gas generated during the annealing of graphene oxide are believed to play an important role during these phase transformations. These samples showed good electromagnetic wave absorption performance due to their electromagnetic complementary effect. These samples possess much better electromagnetic wave absorption properties than the mixture of separately prepared Fe3O4 with rGO, suggesting the crucial role of synthetic method in determining the product properties. Also, these samples perform much better than commercial absorbers. Most importantly, the great stability of these composites is highly advantageous for applications as electromagnetic wave absorption materials at high temperatures.

  20. Heat transfer characteristics of liquid-gas Taylor flows incorporating microencapsulated phase change materials

    International Nuclear Information System (INIS)

    Howard, J A; Walsh, P A

    2014-01-01

    This paper presents an investigation on the heat transfer characteristics associated with liquid-gas Taylor flows in mini channels incorporating microencapsulated phase change materials (MPCM). Taylor flows have been shown to result in heat transfer enhancements due to the fluid recirculation experienced within liquid slugs which is attributable to the alternating liquid slug and gas bubble flow structure. Microencapsulated phase change materials (MPCM) also offer significant potential with increased thermal capacity due to the latent heat required to cause phase change. The primary aim of this work was to examine the overall heat transfer potential associated with combining these two novel liquid cooling technologies. By investigating the local heat transfer characteristics, the augmentation/degradation over single phase liquid cooling was quantified while examining the effects of dimensionless variables, including Reynolds number, liquid slug length and gas void fraction. An experimental test facility was developed which had a heated test section and allowed MPCM-air Taylor flows to be subjected to a constant heat flux boundary condition. Infrared thermography was used to record high resolution experimental wall temperature measurements and determine local heat transfer coefficients from the thermal entrance point. 30.2% mass particle concentration of the MPCM suspension fluid was examined as it provided the maximum latent heat for absorption. Results demonstrate a significant reduction in experimental wall temperatures associated with MPCM-air Taylor flows when compared with the Graetz solution for conventional single phase coolants. Total enhancement in the thermally developed region is observed to be a combination of the individual contributions due to recirculation within the liquid slugs and also absorption of latent heat. Overall, the study highlights the potential heat transfer enhancements that are attainable within heat exchange devices employing MPCM

  1. The accuracy of liquid-liquid phase transition temperatures determined from semiautomated light scattering measurements

    Science.gov (United States)

    Dean, Kevin M.; Babayco, Christopher B.; Sluss, Daniel R. B.; Williamson, J. Charles

    2010-08-01

    The synthetic-method determination of liquid-liquid coexistence curves using semiautomated light scattering instrumentation and stirred samples is based on identifying the coexistence curve transition temperatures (Tcx) from sudden changes in turbidity associated with droplet formation. Here we use a thorough set of such measurements to evaluate the accuracy of several different analysis methods reported in the literature for assigning Tcx. More than 20 samples each of weakly opalescent isobutyric acid+water and strongly opalescent aniline+hexane were tested with our instrumentation. Transmitted light and scattering intensities at 2°, 24°, and 90° were collected simultaneously as a function of temperature for each stirred sample, and the data were compared with visual observations and light scattering theory. We find that assigning Tcx to the onset of decreased transmitted light or increased 2° scattering has a potential accuracy of 0.01 K or better for many samples. However, the turbidity due to critical opalescence obscures the identification of Tcx from the light scattering data of near-critical stirred samples, and no simple rule of interpretation can be applied regardless of collection geometry. At best, when 90° scattering is collected along with transmitted or 2° data, the accuracy of Tcx is limited to 0.05 K for near-critical samples. Visual determination of Tcx remains the more accurate approach in this case.

  2. Infrared nanoscopy down to liquid helium temperatures

    Science.gov (United States)

    Lang, Denny; Döring, Jonathan; Nörenberg, Tobias; Butykai, Ádám; Kézsmárki, István; Schneider, Harald; Winnerl, Stephan; Helm, Manfred; Kehr, Susanne C.; Eng, Lukas M.

    2018-03-01

    We introduce a scattering-type scanning near-field infrared microscope (s-SNIM) for the local scale near-field sample analysis and spectroscopy from room temperature down to liquid helium (LHe) temperature. The extension of s-SNIM down to T = 5 K is in particular crucial for low-temperature phase transitions, e.g., for the examination of superconductors, as well as low energy excitations. The low temperature (LT) s-SNIM performance is tested with CO2-IR excitation at T = 7 K using a bare Au reference and a structured Si/SiO2-sample. Furthermore, we quantify the impact of local laser heating under the s-SNIM tip apex by monitoring the light-induced ferroelectric-to-paraelectric phase transition of the skyrmion-hosting multiferroic material GaV4S8 at Tc = 42 K. We apply LT s-SNIM to study the spectral response of GaV4S8 and its lateral domain structure in the ferroelectric phase by the mid-IR to THz free-electron laser-light source FELBE at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. Notably, our s-SNIM is based on a non-contact atomic force microscope (AFM) and thus can be complemented in situ by various other AFM techniques, such as topography profiling, piezo-response force microscopy (PFM), and/or Kelvin-probe force microscopy (KPFM). The combination of these methods supports the comprehensive study of the mutual interplay in the topographic, electronic, and optical properties of surfaces from room temperature down to 5 K.

  3. Does Parmelina tiliacea lichen photosystem II survive at liquid nitrogen temperatures?

    Science.gov (United States)

    Oukarroum, Abdallah; El Gharous, Mohamed; Strasser, Reto J

    2017-02-01

    Parmelina tiliacea lichens kept in the wet and dry state were stored in liquid nitrogen for 1 week and the subsequent recovery of their photosynthetic apparatus was followed. The chlorophyll a fluorescence rise and the maximum quantum yield of primary photochemistry φ Po (F V /F M ) were analysed for this purpose. Storage of wet thalli for 1 week in liquid nitrogen led to an impairment of photosystem II and probably the photosynthetic apparatus as a whole, from which the thalli did not recover over time. Thalli exposed in the dry state thalli were far less affected by the treatment and recovered well. These results indicate that the thalli are extremely tolerant to liquid nitrogen temperatures only in the dry state. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Formula for radial profiles of temperature in steam-liquid sodium reactive jets

    International Nuclear Information System (INIS)

    Hobbes, P.; Mora-Perez, J.L.; Carreau, J.L.; Gbahoue, L.; Roger, F.

    1987-01-01

    One of the important problems of the study of distribution of temperatures in the reactive steam-liquid sodium jet rests in the mathematical formulation of their radial effects. During the experiment, two forms have been brought to light: from a certain distance of the injector, the radial distribution of temperature can be represented, in a classical way, by an error function curve; close to the injector, the radial profile allows for a minimum located on the axis of the jet. An energy balance permits, by dividing the jet in three parts: a central nucleus composed of practically pure gas, a gas ring plus drops and a liquid peripheral area plus bubbles, to obtain a mathematical formulation of the profiles, close to the injection which accounts quite well for the experimental points and their form

  5. Study on Relative COP Changes with Increasing Heat Input Temperatures of Double Effect Steam Absorption Chillers

    Directory of Open Access Journals (Sweden)

    Abd Majid Mohd Amin

    2016-01-01

    Full Text Available Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers are mainly of double effect type. The COP of double effect varies from 0.7 to 1.2 depending on operation and maintenance practices of the chillers. Heat input to the chillers during operations could have impact on the COP of the chillers. This study is on relative COP changes with increasing the heat input temperatures for a steam absorption chiller at a gas fueled cogeneration plant. Reversible COP analysis and zero order model were used for evaluating COP of the chiller for 118 days operation period. Results indicate increasing COP trends for both the reversible COP and zero model COP. Although the zero model COP are within the range of double effect absorption chiller, it is not so for the actual COP. The actual COP is below the range of normal double effect COP. It is recommended that economic replacement analysis to be undertaken to assess the feasibility either to repair or replace the existing absorption chiller.

  6. Fission-Product Separation Based on Room-Temperature Ionic-Liquids

    International Nuclear Information System (INIS)

    Hussey, Charles L.

    2005-01-01

    During the previous funding cycle for this project, we investigated the electrochemistry of Cs(I) in air and moisture-stable ionic liquids both with and without the addition of BOBCalixC6. These investigations revealed that the electrochemical windows of the dialkylimidazolium bis[(trifluoromethyl)sulfonyl]imide ionic liquids do not permit the direct electrochemical reduction of Cs(I), even when Hg electrodes are employed, because these organic cations are reduced at less negative potentials than Cs(I). However, Cs(I) coordinated by BOBCalixC6 can be electrolytically reduced to Cs(Hg) in tetraalkylammonium-based room-temperature ionic liquids such as tri-1-butylmethylammonium bis[(trifluoromethyl)sulfonyl]imide (Bu3MeN+Tf2N-) at Hg electrodes. Because this reduction process does not harm either the ionic liquid or the macrocycle, it is a promising method for recycling the cesium extraction system. The previous studies mentioned above were carried out under an inert atmosphere, i.e., in the absence of H2O and O2. However, it may not be economically feasible or even possible to carry out the recycling process in the absence of these contaminants during large-scale processing of aqueous tank waste. Thus, as described in our proposal, we have begun an investigation of the electrochemical recovery of Cs from the Bu3MeN+Tf2N- + BOBCalixC6 extraction system in an air atmosphere containing various amounts of water and oxygen. Our recent preliminary results were very surprising because they indicated that the electrochemical extraction process is relatively insensitive to the presence of small amounts of moisture even when the moisture content of the ionic liquid approaches 1000 ppm. Furthermore, we have found that the ''wet'' ionic liquid can be easily dehydrated under reduced pressure or by sparging with dry nitrogen gas without the need for heat or any other specialized treatment

  7. Methanol absorption characteristics for the removal of H2S (hydrogen sulfide), COS (carbonyl sulfide) and CO2 (carbon dioxide) in a pilot-scale biomass-to-liquid process

    International Nuclear Information System (INIS)

    Seo, Myung Won; Yun, Young Min; Cho, Won Chul; Ra, Ho Won; Yoon, Sang Jun; Lee, Jae Goo; Kim, Yong Ku; Kim, Jae Ho; Lee, See Hoon; Eom, Won Hyun; Lee, Uen Do; Lee, Sang Bong

    2014-01-01

    The BTL (biomass-to-liquid) process is an attractive process that produces liquid biofuels from biomass. The FT (Fisher–Tropsch) process is used to produce synfuels such as diesel and gasoline from gasified biomass. However, the H 2 S (hydrogen sulfide), COS (carbonyl sulfide) and CO 2 (carbon dioxide) in the syngas that are produced from the biomass gasifiers cause a decrease of the conversion efficiency and deactivates the catalyst that is used in the FT process. To remove the acid gases, a pilot-scale methanol absorption tower producing diesel at a rate of 1 BPD (barrel per day) was developed, and the removal characteristics of the acid gases were determined. A total operation time of 500 h was achieved after several campaigns. The average syngas flow rate at the inlet of methanol absorption tower ranged from 300 to 800 L/min. The methanol absorption tower efficiently removed H 2 S from 30 ppmV to less than 1 ppmV and COS from 2 ppmV to less than 1 ppmV with a removal of CO 2 from 20% to 5%. The outlet gas composition adhered to the guidelines for FT reactors. No remaining sulfurous components were found, and the tar component was analyzed in the spent methanol after long-term operations. - Highlights: • The gas cleaning system in a pilot-scale BTL (biomass-to-liquid) process is reported. • Although methanol absorption tower is conventional process, its application to BTL process is attempted. • The methanol absorption tower efficiently removed H 2 S, COS and CO 2 in the syngas. • The sulfurous and tar components in the methanol are analyzed

  8. Combination of flame atomic absorption spectrometry with ligandless-dispersive liquid- liquid microextraction for preconcentration and determination of trace amount of lead in water samples

    Directory of Open Access Journals (Sweden)

    Y.M. Baghelani

    2013-05-01

    Full Text Available A new ligandless-dispersive liquid–liquid microextraction method has been developed for the separation and flame atomic absorption spectrometry determination of trace amount of lead(II ion. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents. Factors influencing the extraction efficiency of lead, including the extraction and dispersive solvent type and volume, pH of sample solution, concentration of chloride and extraction time were studied. Under the optimal conditions, the calibration curve was linear in the range of 7.0–6000 ng mL−1 of lead with R2 = 0.9992 (n = 10 and detection limit based on three times the standard deviation of the blank (3Sb was 0.5 ng mL−1 in original solution. The relative standard deviation for eight replicate determinations of 1.0 mg mL-1 lead was ±1.6%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of trace amounts of lead in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in water samples and satisfactory results were obtained. The accuracy was checked by analyzing a certified reference material from the National Institute of Standard and Technology, Trace elements in water (NIST CRM 1643e.

  9. Liquid-solid contact measurements using a surface thermocouple temperature probe in atmospheric pool boiling water

    International Nuclear Information System (INIS)

    Lee, L.Y.W.; Chen, J.C.; Nelson, R.A.

    1984-01-01

    Objective was to apply the technique of using a microthermocouple flush-mounted at the boiling surface for the measurement of the local-surface-temperature history in film and transition boiling on high temperature surfaces. From this measurement direct liquid-solid contact in film and transition boiling regimes was observed. In pool boiling of saturated, distilled, deionized water on an aluminum-coated copper surface, the time-averaged, local-liquid-contact fraction increased with decreasing surface superheat. Average contact duration increased monotonically with decreasing surface superheat, while frequency of liquid contact reached a maximum of approx. 50 contacts/s at a surface superheat of approx. 100 K and decreased gradually to 30 contacts/s near the critical heat flux. The liquid-solid contact duration distribution was dominated by short contacts 4 ms at low surface superheats, passing through a relatively flat contact duration distribution at about 80 0 K. Results of this paper indicate that liquid-solid contacts may be the dominant mechanism for energy transfer in the transition boiling process

  10. CFCI3 (CFC-11): UV Absorption Spectrum Temperature Dependence Measurements and the Impact on Atmospheric Lifetime and Uncertainty

    Science.gov (United States)

    Mcgillen, Max R.; Fleming, Eric L.; Jackman, Charles H.; Burkholder, James B.

    2014-01-01

    CFCl3 (CFC-11) is both an atmospheric ozone-depleting and potent greenhouse gas that is removed primarily via stratospheric UV photolysis. Uncertainty in the temperature dependence of its UV absorption spectrum is a significant contributing factor to the overall uncertainty in its global lifetime and, thus, model calculations of stratospheric ozone recovery and climate change. In this work, the CFC-11 UV absorption spectrum was measured over a range of wavelength (184.95 - 230 nm) and temperature (216 - 296 K). We report a spectrum temperature dependence that is less than currently recommended for use in atmospheric models. The impact on its atmospheric lifetime was quantified using a 2-D model and the spectrum parameterization developed in this work. The obtained global annually averaged lifetime was 58.1 +- 0.7 years (2 sigma uncertainty due solely to the spectrum uncertainty). The lifetime is slightly reduced and the uncertainty significantly reduced from that obtained using current spectrum recommendations

  11. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples

    International Nuclear Information System (INIS)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-01-01

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L -1 with a detection limit of 0.5 μg L -1 . The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L -1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L -1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method

  12. Double-layered liquid crystal light shutter for control of absorption and scattering of the light incident to a transparent display device

    Science.gov (United States)

    Huh, Jae-Won; Yu, Byeong-Hun; Shin, Dong-Myung; Yoon, Tae-Hoon

    2015-03-01

    Recently, a transparent display has got much attention as one of the next generation display devices. Especially, active studies on a transparent display using organic light-emitting diodes (OLEDs) are in progress. However, since it is not possible to obtain black color using a transparent OLED, it suffers from poor visibility. This inevitable problem can be solved by using a light shutter. Light shutter technology can be divided into two types; light absorption and scattering. However, a light shutter based on light absorption cannot block the background image perfectly and a light shutter based on light scattering cannot provide black color. In this work we demonstrate a light shutter using two liquid crystal (LC) layers, a light absorption layer and a light scattering layer. To realize a light absorption layer and a light scattering layer, we use the planar state of a dye-doped chiral nematic LC (CNLC) cell and the focal-conic state of a long-pitch CNLC cell, respectively. The proposed light shutter device can block the background image perfectly and show black color. We expect that the proposed light shutter can increase the visibility of a transparent display.

  13. Influence of the gas-liquid flow configuration in the absorption column on photosynthetic biogas upgrading in algal-bacterial photobioreactors.

    Science.gov (United States)

    Toledo-Cervantes, Alma; Madrid-Chirinos, Cindy; Cantera, Sara; Lebrero, Raquel; Muñoz, Raúl

    2017-02-01

    The potential of an algal-bacterial system consisting of a high rate algal pond (HRAP) interconnected to an absorption column (AC) via recirculation of the cultivation broth for the upgrading of biogas and digestate was investigated. The influence of the gas-liquid flow configuration in the AC on the photosynthetic biogas upgrading process was assessed. AC operation in a co-current configuration enabled to maintain a biomass productivity of 15gm -2 d -1 , while during counter-current operation biomass productivity decreased to 8.7±0.5gm -2 d -1 as a result of trace metal limitation. A bio-methane composition complying with most international regulatory limits for injection into natural gas grids was obtained regardless of the gas-liquid flow configuration. Furthermore, the influence of the recycling liquid to biogas flowrate (L/G) ratio on bio-methane quality was assessed under both operational configurations obtaining the best composition at an L/G ratio of 0.5 and co-current flow operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. UV absorption cross-sections of phenol and naphthalene at temperatures up to 500 degrees C

    DEFF Research Database (Denmark)

    Grosch, Helge; Sárossy, Zsuzsa; Egsgaard, Helge

    2015-01-01

    resolution than before (0.019 nm) in a hot gas flow cell at temperatures of up to 500 degrees C/773 K. A Petersen column is used to sample the organic compounds in the gas mixture to determine their concentration by GC-MS. The absorption cross-sections are calculated with the use of the Lambert-Beer law...

  15. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Directory of Open Access Journals (Sweden)

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  16. Analysis of ammonia/water and ammonia/salt mixture absorption cycles for refrigeration purposes in fishing ships

    International Nuclear Information System (INIS)

    Táboas, Francisco; Bourouis, Mahmoud; Vallès, Manel

    2014-01-01

    In this work, the use of waste heat energy of jacket water in diesel engines of fishing ships was analysed for use as a heat source for absorption refrigeration systems. The thermodynamic simulation of an absorption refrigeration cycle with three different working fluid mixtures that use ammonia as a refrigerant was carried out. This analysis was assessed in terms of the cooling demand and cycle performance as a function of the evaporator, condenser and generator temperatures. Moreover, the need for rectifying the vapour stream leaving the generator was analysed together with the drag of the fraction of non-evaporated liquid to the absorber. The results show that the NH 3 /(LiNO 3  + H 2 O) and NH 3 /LiNO 3 fluid mixtures have higher values of COP as compared to NH 3 /H 2 O fluid mixture, the differences being more pronounced at low generation temperatures. If the activation temperature is set to 85 °C, the minimum evaporation temperatures that can be achieved are −18.8 °C for the cycle with NH 3 /LiNO 3 , −17.5 °C for the cycle with NH 3 /(LiNO 3  + H 2 O) cycle and −13.7 °C for the NH 3 /H 2 O cycle at a condensing temperature of 25 °C. Also, for the NH 3 /(LiNO 3  + H 2 O) fluid mixture, it has been demonstrated that the absorption refrigeration cycle can be operated without a distillation column and in this case the water content in the refrigerant stream entering the evaporator is less than 1.5% in weight at the operating conditions selected. - Highlights: •Ammonia absorption systems can provide refrigeration necessities for fishing ships. •Absorption refrigeration systems reduce the energy consumption of fishing ships. •The NH 3 /(LiNO 3  + H 2 O) mixture is recommended for absorption refrigeration cycles

  17. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Calle, Inmaculada de la; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2016-09-14

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included. - Highlights: • We review the LPME-GFAAS combination in a comprehensive way. • A brief description of main LPME modes is included. • Effect of experimental parameters in the performance of LPME-GFAAS is discussed. • Main applications for trace element analysis and speciation are reviewed.

  18. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review

    International Nuclear Information System (INIS)

    Calle, Inmaculada de la; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2016-01-01

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included. - Highlights: • We review the LPME-GFAAS combination in a comprehensive way. • A brief description of main LPME modes is included. • Effect of experimental parameters in the performance of LPME-GFAAS is discussed. • Main applications for trace element analysis and speciation are reviewed.

  19. Soft X-ray and cathodoluminescence measurement, optimisation and analysis at liquid nitrogen temperatures

    Science.gov (United States)

    MacRae, C. M.; Wilson, N. C.; Torpy, A.; Delle Piane, C.

    2018-01-01

    Advances in field emission gun electron microprobes have led to significant gains in the beam power density and when analysis at high resolution is required then low voltages are often selected. The resulting beam power can lead to damage and this can be minimised by cooling the sample down to cryogenic temperatures allowing sub-micrometre imaging using a variety of spectrometers. Recent advances in soft X-ray emission spectrometers (SXES) offer a spectral tool to measure both chemistry and bonding and when combined with spectral cathodoluminescence the complementary techniques enable new knowledge to be gained from both mineral and materials. Magnesium and aluminium metals have been examined at both room and liquid nitrogen temperatures by SXES and the L-emission Fermi-edge has been observed to sharpen at the lower temperatures directly confirming thermal broadening of the X-ray spectra. Gains in emission intensity and resolution have been observed in cathodoluminescence for liquid nitrogen cooled quartz grains compared to ambient temperature quartz. This has enabled subtle growth features at quartz to quartz-cement boundaries to be imaged for the first time.

  20. H2O temperature sensor for low-pressure flames using tunable diode laser absorption near 2.9 νm

    KAUST Repository

    Li, Sijie

    2011-10-19

    Making use of a newly available rapid-tuning diode laser operating at wavelengths up to 2.9 νm, an absorption-based temperature sensor was developed for in situ measurements in low-pressure flames. Based on the systematic analysis of H2O vapor transitions in the fundamental vibrational bands (ν1 and ν3) of H2O in the range of 2.5-3.0 νm, an optimal closely-spaced spectral line pair near 2.9 νm was selected for its temperature sensitivity in the range of 1000-2500 K. The narrow-linewidth room-temperature laser was scanned repetitively across these spectral features at 5 kHz, enabling fast, accurate temperature sensing. Use of the temperature sensor was investigated in low-pressure flames supported on a McKenna burner at 15, 25 and 60 Torr. To avoid absorption by the cold gases in the flame edges and the recirculation region between the burner and the vacuum chamber wall, a variable-path in situ probe was designed and an optimal path length was determined to accurately measure the flame centerline temperature. Different flame conditions were investigated to illustrate the potential of this sensor system for sensitive measurements of combustion temperature in low-pressure flames. © 2011 IOP Publishing Ltd.

  1. Modeling of radionuclide migration and a temperature dynamics in underground disposal of liquid radioactive waste

    International Nuclear Information System (INIS)

    Larin, V.K.; Zubkov, A.A.; Balakhonov, V.G.; Sukhorukov, V.A.; Zhiganov, A.N.; Noskov, M.D.; Istomin, A.D.; Kesler, A.G.

    2002-01-01

    Mathematical model of radionuclide migration and temperature field dynamics during underground disposal of liquid radioactive wastes is presented. The model involves the description of filtration, convective-dispersion mass transfer, sorption and desorption of radionuclides, radioactive decay, convective heat transport and hear transfer. Software making possible to conduct prognosis calculations of changing state of stratum-collector of radioactive wastes was made. Results of the simulation of temperature field dynamics and behaviour of radionuclides on underground disposal of liquid radioactive wastes of the Siberian chemical plant are performed [ru

  2. Room-Temperature Synthesis of Transition Metal Clusters and Main Group Polycations from Ionic Liquids

    OpenAIRE

    Ahmed, Ejaz

    2011-01-01

    Main group polycations and transition metal clusters had traditionally been synthesized via high-temperature routes by performing reactions in melts or by CTR, at room-temperature or lower temperature by using so-called superacid solvents, and at room-temperature in benzene–GaX3 media. Considering the major problems associated with higher temperature routes (e.g. long annealing time, risk of product decomposition, and low yield) and taking into account the toxicity of benzene and liquid SO2 i...

  3. Ultrasonic Relaxation Study of 1-Alkyl-3-methylimidazolium-Based Room-Temperature Ionic Liquids: Probing the Role of Alkyl Chain Length in the Cation.

    Science.gov (United States)

    Zorębski, Michał; Zorębski, Edward; Dzida, Marzena; Skowronek, Justyna; Jężak, Sylwia; Goodrich, Peter; Jacquemin, Johan

    2016-04-14

    Ultrasound absorption spectra of four 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imides were determined as a function of the alkyl chain length on the cation from 1-propyl to 1-hexyl from 293.15 to 323.15 K at ambient pressure. Herein, the ultrasound absorption measurements were carried out using a standard pulse technique within a frequency range from 10 to 300 MHz. Additionally, the speed of sound, density, and viscosity have been measured. The presence of strong dissipative processes during the ultrasound wave propagation was found experimentally, i.e., relaxation processes in the megahertz range were observed for all compounds over the whole temperature range. The relaxation spectra (both relaxation amplitude and relaxation frequency) were shown to be dependent on the alkyl side chain length of the 1-alkyl-3-methylimidazolium ring. In most cases, a single-Debye model described the absorption spectra very well. However, a comparison of the determined spectra with the spectra of a few other imidazolium-based ionic liquids reported in the literature (in part recalculated in this work) shows that the complexity of the spectra increases rapidly with the elongation of the alkyl chain length on the cation. This complexity indicates that both the volume viscosity and the shear viscosity are involved in relaxation processes even in relatively low frequency ranges. As a consequence, the sound velocity dispersion is present at relatively low megahertz frequencies.

  4. Quantitative structure—property relationship for thermal decomposition temperature of ionic liquids

    DEFF Research Database (Denmark)

    Gharagheizi, Farhad; Sattari, Mehdi; Ilani-Kashkouli, Poorandokht

    2012-01-01

    In this study, a wide literature survey has been conducted to gather an extensive set of thermal decomposition temperature (Td) data for ionic liquids (ILs). A data set consisting of Td data for 586 ILs was collated from 71 different literature sources. Using this data set, a reliable quantitativ...

  5. Towards Molecular Dynamics Simulations of Chiral Room-Temperature Ionic Liquids

    Czech Academy of Sciences Publication Activity Database

    Lísal, Martin; Chval, Z.; Storch, Jan; Izák, Pavel

    2014-01-01

    Roč. 189, SI (2014), s. 85-94 ISSN 0167-7322 R&D Projects: GA ČR(CZ) GAP106/12/0569; GA MŠk LH12020 Institutional support: RVO:67985858 Keywords : chiral room-temperature ionic liquid * molecular dynamics simulation * non-polarizable fully flexible all-atom force field Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.515, year: 2014

  6. A novel separation/preconcentration technique based on ultrasonic dispersion liquid-liquid microextraction for determination of trace cobalt by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Jingci Li

    2012-12-01

    Full Text Available An improved method for the determination of trace cobalt in water samples has been developed using ultrasonic dispersion liquid-liquid microextraction (US-DLLME prior to flame atomic absorption spectrometry (FAAS analysis. In this method, cobalt was extracted into the fine droplets of carbon tetrachloride after chelate formation with the water soluble ligand, ammonium pyrrolidine dithiocarbamate (APDC. The fine droplets of carbon tetrachloride were formed and dispersed in the aqueous sample with the help of ultrasonic waves which accelerated the formation of the fine cloudy solution without using disperser solvents. Under optimum conditions, the calibration curve was linear in the range of 2.5-500 μg L-1, with a detection limit of 0.8 μg L-1. The relative standard deviation (RSD for ten replicate measurements of 20 and 500 μg L-1 of cobalt were 3.3 and 2.2%. This proposed method was successfully applied to tap water, river water, and sea water, and accuracy was assessed through the analysis of certified reference water or recovery experiments. Operation simplicity, low cost, high enrichment factor, and low consumption of the extraction solvent are the main advantages of the proposed method.DOI: http://dx.doi.org/10.4314/bcse.v26i1.2

  7. High Resolution Temperature Measurement of Liquid Stainless Steel Using Hyperspectral Imaging

    Directory of Open Access Journals (Sweden)

    Wim Devesse

    2017-01-01

    Full Text Available A contactless temperature measurement system is presented based on a hyperspectral line camera that captures the spectra in the visible and near infrared (VNIR region of a large set of closely spaced points. The measured spectra are used in a nonlinear least squares optimization routine to calculate a one-dimensional temperature profile with high spatial resolution. Measurements of a liquid melt pool of AISI 316L stainless steel show that the system is able to determine the absolute temperatures with an accuracy of 10%. The measurements are made with a spatial resolution of 12 µm/pixel, justifying its use in applications where high temperature measurements with high spatial detail are desired, such as in the laser material processing and additive manufacturing fields.

  8. Kinetics and mechanisms of interactions of nitrogen and carbon monoxide with liquid niobium

    International Nuclear Information System (INIS)

    Park, H.G.

    1990-01-01

    The kinetics and mechanisms of interactions of N 2 and CO with liquid niobium were investigated in the temperature range of 2,700 to 3,000 K in samples levitated in N 2 /Ar and CO/Ar streams. The nitrogen absorption and desorption processes were found to be second-order with respect to nitrogen concentration, indicating that the rate controlling step is either the adsorption of nitrogen molecules on the liquid surface or dissociation of absorbed nitrogen molecules into adsorbed atoms. The carbon and oxygen dissolution in liquid niobium from CO gas is an exothermic process and the solubilities of carbon and oxygen (C Ce , C Oe in at%) are related to the temperature and the partial pressure of CO. The reaction CO → [C] + [O] along with the evaporation of niobium oxide takes place during C and O dissolution, whereas C and O desorption occurs via CO evolution only

  9. Electrochemical characterization of Uranyl-TODGA complex in a room temperature ionic liquid

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Murali, M.S.; Mohapatra, P.K.

    2014-01-01

    Room temperature ionic liquids are new materials finding extensive use in many applications such as syntheses, catalysis, electrochemistry etc. including separation science. Some of them are known as green solvents set to be environment-friendly. With a view to apply the favourable properties of these neoteric solvents to separation science in nuclear related fields such as reprocessing and waste remediation, electrochemical characterization of the metal ions encountered in above fields e.g. U(VI), Pu(IV), Np(IV), Am(III) etc. their complexes with the ligands often becomes necessary and useful. In the present piece of work, electrochemical characterization has been carried out by cyclic voltammetry of uranyl complex with one of the most promising trivalent actinide extractants, namely, tetraoctyldiglycolamide (TODGA) dissolved/extracted into a room temperature ionic liquid, 1-methyl-3-octyl imidazolium bis(trifluoro methylsulphonyl) imide (C 8 mimNTf 2 )

  10. (Liquid + liquid) equilibria of perfluorocarbons with fluorinated ionic liquids

    International Nuclear Information System (INIS)

    Martinho, S.; Araújo, J.M.M.; Rebelo, L.P.N.; Pereiro, A.B.; Marrucho, I.M.

    2013-01-01

    Highlights: • (Liquid + liquid) equilibria perfluorocarbons and fluorinated ionic liquids. • Non-Random Two Liquid model was successfully applied. • Thermodynamic functions that describe the solvation process were calculated. -- Abstract: In order to evaluate the feasibility of partially replace perfluorocarbons (PFCs) with fluorinated ionic liquids (FILs) in PFCs-in-water emulsions, usually used for biomedical purposes, herein the (liquid + liquid) phase equilibria of FILs containing fluorinated chains longer than four carbons with PFCs were carried out in a wide range of temperatures. With this goal in mind, two PFCs (perfluorooctane and perfluorodecalin) were selected and the (liquid + liquid) equilibria of the binary mixtures of these PFCs and FILs were studied at atmospheric pressure in a temperature range from T (293.15 to 343.15) K. For these studies, FILs containing ammonium, pyridinium and imidazolium cations and different anions with fluorocarbon alkyl chains between 4 and 8 were included. Additionally, Non-Random Two Liquid (NRTL) thermodynamic model was successfully applied to correlate the behaviour of the PFCs + FILs binary mixtures. Moreover, thermodynamic functions that describe the solvation process were calculated from the experimental data

  11. Separation/preconcentration and determination of vanadium with dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) and electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Asadollahi, Tahereh; Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji

    2010-06-30

    A novel dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for separation/preconcentration of ultra trace amount of vanadium and its determination with the electrothermal atomic absorption spectrometry (ETAAS) was developed. The DLLME-SFO behavior of vanadium (V) using N-benzoyl-N-phenylhydroxylamine (BPHA) as complexing agent was systematically investigated. The factors influencing the complex formation and extraction by DLLME-SFO method were optimized. Under the optimized conditions: 100 microL, 200 microL and 25 mL of extraction solvent (1-undecanol), disperser solvent (acetone) and sample volume, respectively, an enrichment factor of 184, a detection limit (based on 3S(b)/m) of 7 ng L(-1) and a relative standard deviation of 4.6% (at 500 ng L(-1)) were obtained. The calibration graph using the preconcentration system for vanadium was linear from 20 to 1000 ng L(-1) with a correlation coefficient of 0.9996. The method was successfully applied for the determination of vanadium in water and parsley. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Thermodynamic analysis into a heat exchanger for absorption at high temperatures

    International Nuclear Information System (INIS)

    Márquez-Nolasco, A.; Huicochea, A.; Torres-Merino, J.; Siqueiros, J.; Hernández, J.A.

    2016-01-01

    Highlights: • Energy and exergy analyses for split absorber inside an AHT were developed. • The coefficient of operation for energy and exergy were improved above 30%. • A split absorber can reduce the irreversibility up to 28%. - Abstract: The residual heat or renewable energy can be used to activate a thermodynamic cycle inside a heat transformer by absorption (AHT), in order to obtain heat with a higher temperature in whole equipment. The performance of the AHT is mainly influenced by the absorber, since the useful heat is obtained here at different operating conditions. According to this study, a split absorber can improve the performance of the AHT because of the existing absorption processes in accordance with the first and second law of thermodynamics. The proposal is to divide the heat transfer area in equal sections, where the steam supplied is equal and the strong working solution is increased for all sections, in order to diminish the irreversibility in the absorber. With respect to the basic absorber, the best results are found when the absorber has two sections, because COP can be improved from 0.307 to 0.415, while the ECOP from 0.118 to 0.160, besides the irreversibility can reduce up to almost 28%.

  13. Breaking through the glass ceiling: The correlation between the self-diffusivity in and krypton permeation through deeply supercooled liquid nanoscale methanol films

    Science.gov (United States)

    Smith, R. Scott; Matthiesen, Jesper; Kay, Bruce D.

    2010-03-01

    Molecular beam techniques, temperature-programmed desorption (TPD), and reflection absorption infrared spectroscopy (RAIRS) are used to explore the relationship between krypton permeation through and the self-diffusivity of supercooled liquid methanol at temperatures (100-115 K) near the glass transition temperature, Tg (103 K). Layered films, consisting of CH3OH and CD3OH, are deposited on top of a monolayer of Kr on a graphene covered Pt(111) substrate at 25 K. Concurrent Kr TPD and RAIRS spectra are acquired during the heating of the composite film to temperatures above Tg. The CO vibrational stretch is sensitive to the local molecular environment and is used to determine the supercooled liquid diffusivity from the intermixing of the isotopic layers. We find that the Kr permeation and the diffusivity of the supercooled liquid are directly and quantitatively correlated. These results validate the rare-gas permeation technique as a tool for probing the diffusivity of supercooled liquids.

  14. Low Energy Spectrum of Proximate Kitaev Spin Liquid α -RuCl3 by Terahertz Spectroscopy

    Science.gov (United States)

    Little, Arielle; Wu, Liang; Kelley, Paige; Banerjee, Arnab; Bridges, Craig; Yan, Jiaqiang; Nagler, Stephen; Mandrus, David; Orenstein, Joseph

    A Quantum Spin Liquid (QSL) is an ultra-quantum state of matter with no ordered ground state. Recently, a route to a QSL identified by Kitaev has received a great deal of attention. The compound α -RuCl3, in which Ru atoms form a honeycomb lattice, has been shown to possess Kitaev exchange interactions, although a smaller Heisenberg interaction exists and leads to a zig-zag antiferromagnetic state below 7 K. Because of proximity to the exactly-solvable Kitaev spin-liquid model, this material is considered a potential host for Majorana-like modes. In this work, we use time-domain terahertz (THz) Spectroscopy to probe the low-energy excitations of α -RuCl3. We observe the emergence of a sharp magnetic spin-wave absorption peak below the AFM ordering temperature at 7 K on top of a broad continuum that persists up to room temperature. Additionally we report the polarization dependence of the THz absorption, which reveals optical birefringence, indicating the presence of large monoclinic domains.

  15. Model of a liquid droplet impinging on a high-temperature solid surface

    International Nuclear Information System (INIS)

    Gulikov, A.V.; Berlin, I.I.; Karpyshev, A.V.

    2004-01-01

    The model of the collision of the liquid droplet, vertically falling on the heated solid surface, is presented. The wall temperature is predeterminated so that the droplet interaction with the wall proceeds through the gas interlayer (T≥400 Deg C). The droplet liquid is incompressible, nonviscous. The droplet surface is assigned as free one. The pressure is composed of two components. The first component is the surface tension. The record component is the steam pressure between the droplet and the wall. The liquid motion inside the droplet is assumed to be potential, axisymmetric. The calculation of the droplet collision are carried out with application of the above model. The obtained results are compared with the data of other authors [ru

  16. A review of the toxicity of biomass pyrolysis liquids formed at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Diebold, J P [Thermalchemie, Inc., Lakewood, CO (United States)

    1997-04-01

    The scaleup of biomass fast pyrolysis systems to large pilot and commercial scales will expose an increasingly large number of personnel to potential health hazards, especially during the evaluation of the commercial use of the pyrolysis condensates. Although the concept of fast pyrolysis to optimize liquid products is relatively new, low-temperature pyrolysis processes have been used over the aeons to produce charcoal and liquid by-products, e.g., smoky food flavors, food preservatives, and aerosols containing narcotics, e.g., nicotine. There are a number of studies in the historical literature that concern the hazards of acute and long-term exposure to smoke and to the historical pyrolysis liquids formed at low temperatures. The reported toxicity of smoke, smoke food flavors, and fast pyrolysis oils is reviewed. The data found for these complex mixtures suggest that the toxicity may be less than that of the individual components. It is speculated that there may be chemical reactions that take place that serve to reduce the toxicity during aging. 81 refs.

  17. Application of room temperature ionic liquids in advanced fuel cycles RIAR research concept program users

    International Nuclear Information System (INIS)

    Bychkov, Alexander V.; Kormilitsyn, Michael V.; Savochkin, Yuri P.; Osipenko, Alexander G.; Smolensky, Valeri V.; Shadrin, Alexander Yu.; Babain, Vladimir A.

    2005-01-01

    The paper reviews briefly the research program on application of Room Temperature Ionic Liquids (RTILs) in some processes of the nuclear fuel reprocessing, particularly in the uranium-aluminum fuel reprocessing and separation of TPEs and REEs from the PUREX process liquid waste, and approaches to implementation of this program. (author)

  18. Photoluminescence at room temperature of liquid-phase crystallized silicon on glass

    Directory of Open Access Journals (Sweden)

    Michael Vetter

    2016-12-01

    Full Text Available The room temperature photoluminescence (PL spectrum due band-to-band recombination in an only 8 μm thick liquid-phase crystallized silicon on glass solar cell absorber is measured over 3 orders of magnitude with a thin 400 μm thick optical fiber directly coupled to the spectrometer. High PL signal is achieved by the possibility to capture the PL spectrum very near to the silicon surface. The spectra measured within microcrystals of the absorber present the same features as spectra of crystalline silicon wafers without showing defect luminescence indicating the high electronic material quality of the liquid-phase multi-crystalline layer after hydrogen plasma treatment.

  19. Probing Ionic Liquid Aqueous Solutions Using Temperature of Maximum Density Isotope Effects

    Directory of Open Access Journals (Sweden)

    Mohammad Tariq

    2013-03-01

    Full Text Available This work is a new development of an extensive research program that is investigating for the first time shifts in the temperature of maximum density (TMD of aqueous solutions caused by ionic liquid solutes. In the present case we have compared the shifts caused by three ionic liquid solutes with a common cation—1-ethyl-3-methylimidazolium coupled with acetate, ethylsulfate and tetracyanoborate anions—in normal and deuterated water solutions. The observed differences are discussed in terms of the nature of the corresponding anion-water interactions.

  20. Study of dielectric liquids at room temperature for high energy x ray Tomography

    International Nuclear Information System (INIS)

    Lepert, S.

    1989-09-01

    The detection of X rays by means of a dielectric liquid detector system, at room temperature, is discussed. The physico-chemical properties of a dielectric liquid, the construction of a cleaning device and of two electrode configurations, and the utilization of different amplifier models are studied. The results allowed the analysis and characterization of the behavior of the dielectric liquid under X ray irradiation. Data obtained is confirmed by computerized simulation. The choice of Tetramethyl-germanium for the X ray tomography, applied in nondestructive analysis, is explained. The investigation of the system parameters allowed the setting of the basis of a prototype project for a multi-detector [fr

  1. Room temperature ferromagnetism and absorption red-shift in nitrogen-doped TiO2 nanoparticles

    International Nuclear Information System (INIS)

    Gómez-Polo, C.; Larumbe, S.; Monge, M.

    2014-01-01

    Highlights: • N-doped TiO 2 anatase nanoparticles were obtained by sol–gel. • The nanoparticle size, controlled by the N doping, determines lattice parameters. • Correlation between room temperature ferromagnetism and absorption red-shift. • Oxygen vacancies reinforce both phenomena. • Metal transition impurities contribute to the room temperature ferromagnetism. - Abstract: In this work, room-temperature ferromagnetism and the red-shift of the optical absorption is analyzed in nitrogen doped TiO 2 semiconductor nanoparticles. The nanoparticles were synthesized by the sol–gel method using urea as the nitrogen source. Titanium Tetraisopropoxide (TTIP) was employed as the alkoxyde precursor and dissolved in ethanol. The as prepared gels were dried and calcined in air at 300 °C. Additionally, post-annealing treatments under vacuum atmosphere were performed to modify the oxygen stoichiometry of the samples. The anatase lattice parameters, analyzed by means of powder X-ray diffractometry, depend on the nanometer grain size of the nanoparticles (increase and decrease, respectively, of the tetragonal a and c lattice parameters with respect to the bulk values). The diffuse reflectance ultraviolet–visible (UV–Vis) absorbance spectra show a clear red-shift as consequence of the nitrogen and the occurrence of intragap energy levels. The samples display ferromagnetic features at room temperature that are reinforced with the nitrogen content and after the post annealings in vacuum. The results indicate a clear correlation between the room temperature ferromagnetism and the shift of the absorbance spectrum. In both phenomena, oxygen vacancies (either induced by the nitrogen doping or by the post vacuum annealings) play a dominant role. However, we conclude the existence of very low concentration of diluted transition metal impurities that determine the room ferromagnetic response (bound magnetic polaron BMP model). The contraction of the c soft axis of the

  2. Increasing the cooking temperature of meat does not affect nonheme iron absorption from a phytate-rich meal in women

    DEFF Research Database (Denmark)

    Baech, S.B.; Hansen, M.; Bukhave, Klaus

    2003-01-01

    The effect of increasing cooking temperatures of meat on nonheme iron absorption from a composite meal was investigated. Cysteine-containing peptides may have a role in the iron absorption enhancing effect of muscle proteins. Heat treatment can change the content of sulfhydryl groups produced from...... cysteine and thereby affect iron absorption. Twenty-one women (25 +/- 3 y) were served a basic meal without meat and two other meals consisting of the basic meal plus 75 g of pork meat cooked at 70, 95 or 120degreesC. The meals were extrinsically labeled with Fe-55 or Fe-59. Iron absorption was determined...... from measurements of wholebody Fe-59 retention and the activity of Fe-55 and Fe-59 in blood samples. Nonheme iron absorptions were 0.9 (0.5-4.0)% (P = 0.06), 0.7 (0.4-3.9)% (P = 0.1) and 2.0 (1.3-3.1)% (P cooked at 70, 95 or 120degreesC, respectively, was added to the basic...

  3. Integrated two-cylinder liquid piston Stirling engine

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ning; Rickard, Robert; Pluckter, Kevin; Sulchek, Todd, E-mail: todd.sulchek@me.gatech.edu [George W. Woodruff School of Mechanical Engineering and Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States)

    2014-10-06

    Heat engines utilizing the Stirling cycle may run on low temperature differentials with the capacity to function at high efficiency due to their near-reversible operation. However, current approaches to building Stirling engines are laborious and costly. Typically the components are assembled by hand and additional components require a corresponding increase in manufacturing complexity, akin to electronics before the integrated circuit. We present a simple and integrated approach to fabricating Stirling engines with precisely designed cylinders. We utilize computer aided design and one-step, planar machining to form all components of the engine. The engine utilizes liquid pistons and displacers to harness useful work from heat absorption and rejection. As a proof of principle of the integrated design, a two-cylinder engine is produced and characterized and liquid pumping is demonstrated.

  4. Integrated two-cylinder liquid piston Stirling engine

    International Nuclear Information System (INIS)

    Yang, Ning; Rickard, Robert; Pluckter, Kevin; Sulchek, Todd

    2014-01-01

    Heat engines utilizing the Stirling cycle may run on low temperature differentials with the capacity to function at high efficiency due to their near-reversible operation. However, current approaches to building Stirling engines are laborious and costly. Typically the components are assembled by hand and additional components require a corresponding increase in manufacturing complexity, akin to electronics before the integrated circuit. We present a simple and integrated approach to fabricating Stirling engines with precisely designed cylinders. We utilize computer aided design and one-step, planar machining to form all components of the engine. The engine utilizes liquid pistons and displacers to harness useful work from heat absorption and rejection. As a proof of principle of the integrated design, a two-cylinder engine is produced and characterized and liquid pumping is demonstrated.

  5. Integrated two-cylinder liquid piston Stirling engine

    Science.gov (United States)

    Yang, Ning; Rickard, Robert; Pluckter, Kevin; Sulchek, Todd

    2014-10-01

    Heat engines utilizing the Stirling cycle may run on low temperature differentials with the capacity to function at high efficiency due to their near-reversible operation. However, current approaches to building Stirling engines are laborious and costly. Typically the components are assembled by hand and additional components require a corresponding increase in manufacturing complexity, akin to electronics before the integrated circuit. We present a simple and integrated approach to fabricating Stirling engines with precisely designed cylinders. We utilize computer aided design and one-step, planar machining to form all components of the engine. The engine utilizes liquid pistons and displacers to harness useful work from heat absorption and rejection. As a proof of principle of the integrated design, a two-cylinder engine is produced and characterized and liquid pumping is demonstrated.

  6. Transport critical current measurement apparatus using liquid nitrogen cooled high-T(c) superconducting magnet with variable temperature insert.

    Science.gov (United States)

    Nishijima, G; Kitaguchi, H; Tshuchiya, Y; Nishimura, T; Kato, T

    2013-01-01

    We have developed an apparatus to investigate transport critical current (I(c)) as a function of magnetic field and temperature using only liquid nitrogen. The apparatus consists of a (Bi,Pb)(2)Sr(2)Ca(2)Cu(3)O(10) (Bi-2223) superconducting magnet, an outer dewar, and a variable temperature insert (VTI). The magnet, which is operated in depressurized liquid nitrogen, generates magnetic field up to 1.26 T. The sample is also immersed in liquid nitrogen. The pressure in the VTI is controlled from 0.02 to 0.3 MPa, which corresponds to temperature ranging from 66 to 88 K. We have confirmed the long-term stable operation of the Bi-2223 magnet at 1 T. The temperature stability of the sample at high transport current was also demonstrated. The apparatus provides easy-operating I(c) measurement environment for a high-T(c) superconductor up to 500 A in magnetic fields up to 1 T and in temperatures ranging from 66 to 88 K.

  7. The coupled effect of fiber volume fraction and void fraction on hydraulic fluid absorption of quartz/BMI laminates

    Science.gov (United States)

    Hurdelbrink, Keith R.; Anderson, Jacob P.; Siddique, Zahed; Altan, M. Cengiz

    2016-03-01

    Bismaleimide (BMI) resin with quartz (AQ581) fiber reinforcement is a composite material frequently used in aerospace applications, such as engine cowlings and radomes. Various composite components used in aircrafts are exposed to different types of hydraulic fluids, which may lead to anomalous absorption behavior over the service life of the composite. Accurate predictive models for absorption of liquid penetrants are particularly important as the composite components are often exposed to long-term degradation due to absorbed moisture, hydraulic fluids, or similar liquid penetrants. Microstructural features such as fiber volume fraction and void fraction can have a significant effect on the absorption behavior of fiber-reinforced composites. In this paper, hydraulic fluid absorption characteristics of quartz/BMI laminates fabricated from prepregs preconditioned at different relative humidity and subsequently cured at different pressures are presented. The composite samples are immersed into hydraulic fluid at room temperature, and were not subjected to any prior degradation. To generate process-induced microvoids, prepregs were conditioned in an environmental chamber at 2% or 99% relative humidity at room temperature for a period of 24 hours prior to laminate fabrication. To alter the fiber volume fraction, the laminates were fabricated at cure pressures of 68.9 kPa (10 psi) or 482.6 kPa (70 psi) via a hot-press. The laminates are shown to have different levels of microvoids and fiber volume fractions, which were observed to affect the absorption dynamics considerably and exhibited clear non-Fickian behavior. A one-dimensional hindered diffusion model (HDM) was shown to be successful in predicting the hydraulic fluid absorption. Model prediction indicates that as the fabrication pressure increased from 68.9 kPa to 482.6 kPa, the maximum fluid content (M∞) decreased from 8.0% wt. to 1.0% wt. The degree of non-Fickian behavior, measured by hindrance coefficient (

  8. Experimental validation of the Maxwell-Stefan theory for the description of liquid-side mass transfer-absorption of NH3 in water using a stirred cell.

    NARCIS (Netherlands)

    Frank, M.J.W.; Frank, M.J.W.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1996-01-01

    The main goal of this paper is to demonstrate the validity of the Maxwell-Stefan theory for the description of liquid phase mass transport processes in a binary mixture. To critically test this theory absorption experiments of ammonia in water were conducted in a stirred cell. The flux model

  9. Selection of flowing liquid lead target structural materials for accelerator driven transmutation applications

    International Nuclear Information System (INIS)

    Park, J.J.; Buksa, J.J.

    1994-01-01

    The beam entry window and container for a liquid lead spallation target will be exposed to high fluxes of protons and neutrons that are both higher in magnitude and energy than have been experienced in proton accelerators and fission reactors, as well as in a corrosive environment. The structural material of the target should have a good compatibility with liquid lead, a sufficient mechanical strength at elevated temperatures, a good performance under an intense irradiation environment, and a low neutron absorption cross section; these factors have been used to rank the applicability of a wide range of materials for structural containment Nb-1Zr has been selected for use as the structural container for the LANL ABC/ATW molten lead target. Corrosion and mass transfer behavior for various candidate structural materials in liquid lead are reviewed, together with the beneficial effects of inhibitors and various coatings to protect substrate against liquid lead corrosion. Mechanical properties of some candidate materials at elevated temperatures and the property changes resulting from 800 MeV proton irradiation are also reviewed

  10. Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Mauro, N. A., E-mail: namauro@noctrl.edu [Department of Physics, North Central College, Naperville, Illinois 60540 (United States); Vogt, A. J. [Instrument and Source Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Derendorf, K. S. [Mechanical Engineering and Materials Science, Washington University, St. Louis, Missouri 63130 (United States); Johnson, M. L.; Kelton, K. F. [Department of Physics and Institute of Materials Science and Engineering, Washington University, 1 Brookings Drive, St. Louis, Missouri 63130 (United States); Rustan, G. E.; Quirinale, D. G.; Goldman, A. I. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Kreyssig, A. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Division of Materials Sciences and Engineering, Ames Laboratory, Ames, Iowa 50011 (United States); Lokshin, K. A. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States); Quantum Condensed Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Neuefeind, J. C.; An, Ke [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Wang, Xun-Li [Department of Physics and Materials Science, City University of Hong Kong, 83 Tat Chee Ave., Kowloon (Hong Kong); Egami, T. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States); Department of Physics and Astronomy, Joint Institute for Neutron Sciences, University of Tennessee, Knoxville, Tennessee 37996 (United States)

    2016-01-15

    Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

  11. Investigation of the thermophysical properties of oxide ceramic materials at liquid-helium temperatures

    International Nuclear Information System (INIS)

    Taranov, A. V.; Khazanov, E. N.

    2008-01-01

    The main regularities in the transport of thermal phonons in oxide ceramic materials are investigated at liquid-helium temperatures. The dependences of the thermophysical characteristics of ceramic materials on their structural parameters (such as the grain size R, the grain boundary thickness d, and the structure of grain boundaries) are analyzed. It is demonstrated that, in dense coarse-grained ceramic materials with qR>>1 (where q is the phonon wave vector), the grain boundaries and the grain size are the main factors responsible for the thermophysical characteristics of the material at liquid-helium temperatures. A comparative analysis of the thermophysical characteristics of optically transparent ceramic materials based on the Y 3 Al 5 O 12 (YAG) and Y 2 O 3 cubic oxides synthesized under different technological conditions is performed using the proposed criterion

  12. Speciation of arsenic in baby foods and the raw fish ingredients using liquid chromatography-hydride generation-atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vinas, P.; Lopez-Garcia, I.; Merino-Merono, B.; Campillo, N.; Hernandez-Cordoba, M. [Murcia Univ. (Spain). Dept. of Analytical Chemistry

    2003-07-01

    The speciation of arsenic in different baby foods and the raw fish ingredients using the direct hybridisation of liquid chromatography (LC) and hydride generation atomic absorption spectrometry (HGAAS) is described. Good resolution of the species, arsenic(III), dimethylarsinic acid (DMAA), monomethylarsenic acid (MMAA) and arsenic(V) is achieved using an anion-exchange column with potassium phosphate as the mobile phase and gradient elution. Arsenobetaine (AsB) is determined by on-line oxidation using peroxydisulphate and hydride generation. The arsenicals were extracted by an enzymatic digestion procedure based on the action of trypsin or pancreatin. Arsenobetaine was the only arsenic species detected. The reliability of the procedure was checked by analyzing the total arsenic content of the samples by electrothermal atomic absorption spectrometry with microwave-oven digestion and by analyzing a certified reference material. The arsenic content in the baby foods comes from the raw fish ingredients and is highest when plaice is used. (orig.)

  13. Study and selection of structured packing material: metallic, polymeric or ceramic to operate a column of absorption polluting gases coming from brick kilns efficiently

    International Nuclear Information System (INIS)

    Salazar P, A.

    2012-01-01

    In this research three structured packing materials were characterized: a metallic, polymeric and ceramic. The study of the physical properties of structured packing materials, and their behavior within the absorption column allowed to suggest a gas-liquid contactor material with higher mechanical and chemical resistance, which is more efficient for the treatment of sour gases from brick kilns. To study the mechanical properties (hardness, tension and elastic modulus) were used procedures of the American Society for Testing Materials, as well as resistance to corrosion. The geometric characteristics, the density, the melting temperature and the weight were tested with procedures of the measuring equipment. The structure was evaluated by X-ray diffraction, morphology was observed by scanning electron microscopy coupled to a sound of dispersive energy of X-ray, to quantify elemental chemical composition. The interaction of gas-liquid contactors materials in presence of CO 2 , was evaluated in three absorption columns built of Pyrex glass, with a diameter of 0.1016 m, of 1.5 m in height, 0.0081m 2 cross-sectional area, packed with every kind of material: metallic, polymeric and ceramic, processing a gas flow of 20m 3 / h at 9% CO 2 , in air and a liquid flow to 30% of Mea 5 L/min. The results of the properties studied were by the metallic material: more density, higher roughness, the greater tensile strength, greater resistance to corrosion in the presence of an aqueous solution of monoethanolamine (Mea) to 30% by weight, improvement more efficient absorption of CO 2 , and higher modulus of elasticity. The polymeric material was characterized to have lower hardness, lower roughness, lower density, lower melting temperature, greater resistance to corrosion in the presence of 1 N H 2 SO 4 aqueous solution, and allowed an absorption efficiency of CO 2 , 2% lower than that presented by the material metallic. The ceramic material found to be the hardest of the three

  14. Effect of meal composition on calcium absorption: enhancing effect of carbohydrate polymers

    International Nuclear Information System (INIS)

    Kelly, S.E.; Chawla-Singh, K.; Sellin, J.H.; Yasillo, N.J.; Rosenberg, I.H.

    1984-01-01

    Meal components including fat, fiber, and carbohydrates can influence the intestinal absorption of calcium; such interactions may be of even greater importance in the presence of intestinal disease. This study compares intestinal absorption of 47CaCl2 administered in four ways: in water, within a standard meal, with a liquid formula (Ensure, Ross Laboratories, Columbus, Ohio), or with a glucose polymer solution (Frodex-15, Ross). Studies were carried out in 9 patients with ileal resection, 3 patients with jejunoileal bypass, and 14 controls. Fractional calcium absorption from water was lower in patients than in controls. Absorption was enhanced 1.5- to 5-fold when 47CaCl2 was administered with a liquid formula diet containing a glucose polymer or with the glucose polymer alone. Patients with the lowest calcium absorption from breakfast showed the greatest effect of calcium ingestion with formula or glucose polymer. These findings further emphasize the importance of meal composition on calcium absorption and provide a possible mechanism for enhancing calcium absorption in some patients with chronically impaired absorption

  15. Thermocapillary migration of liquid droplets in a temperature gradient in a density matched system

    Science.gov (United States)

    Rashidnia, N.; Balasubramaniam, R.

    1991-01-01

    An experimental investigation of thermocapillary flow in droplets of a vegetable oil (partially hydrogenated soybean oil) immersed in silicone oil was conducted in a test cell with a heated top wall and a cooled bottom wall. The liquids are nearly immiscible and have equal densities at a temperature below the room temperature, thus providing a simulation of low-gravity conditions by reducing the buoyancy forces. The interfacial tension between the two oils was measured in the temperature range 20 to 50 C using a capillary tube and (d sigma)/(d T) was determined to be negative. Droplets ranging in sizes from 3 mm to 1 cm diameter were injected into the silicone oil. The vertical temperature profile in the bulk liquid (silicone oil) produces temperature variations along the interface which induce variations in the interfacial tension. The flow inside the droplet driven by the resulting interfacial shear stresses was observed using a laser light-sheet flow visualization technique. The flow direction is consistent with the sign of (d sigma)/(d T). The observed maximum surface velocities are compared to the theoretical predictions of Young et al. (1959).

  16. Simple method for highlighting the temperature distribution into a liquid sample heated by microwave power field

    International Nuclear Information System (INIS)

    Surducan, V.; Surducan, E.; Dadarlat, D.

    2013-01-01

    Microwave induced heating is widely used in medical treatments, scientific and industrial applications. The temperature field inside a microwave heated sample is often inhomogenous, therefore multiple temperature sensors are required for an accurate result. Nowadays, non-contact (Infra Red thermography or microwave radiometry) or direct contact temperature measurement methods (expensive and sophisticated fiber optic temperature sensors transparent to microwave radiation) are mainly used. IR thermography gives only the surface temperature and can not be used for measuring temperature distributions in cross sections of a sample. In this paper we present a very simple experimental method for temperature distribution highlighting inside a cross section of a liquid sample, heated by a microwave radiation through a coaxial applicator. The method proposed is able to offer qualitative information about the heating distribution, using a temperature sensitive liquid crystal sheet. Inhomogeneities as smaller as 1°-2°C produced by the symmetry irregularities of the microwave applicator can be easily detected by visual inspection or by computer assisted color to temperature conversion. Therefore, the microwave applicator is tuned and verified with described method until the temperature inhomogeneities are solved

  17. Solvent refining of low-temperature tar with liquid ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, K

    1953-01-01

    The middle fractions of low-temperature tar were treated with mixed solutions of H/sub 2/O and liquid NH/sub 3/ at 0/sup 0/ and 20/sup 0/, and with liquid NH/sub 3/ at -10, 0, + 10, and 20/sup 0/, and phase equilibrium between tar acids, neutral oil, and solvents were studied. The distribution ratio ranged from less than 1 to greater than 1 when the solvent contained about 20 percent (by weight) H/sub 2/O. When the solvent contained less than 85 percent (by weight) NH/sub 3/, the yield of extract was small but the purity of phenols in the extracted oil was above 90 percent. Solvent containing about 85 percent NH/sub 3/ (by weight) is considered optimum for separating tar acids from oils. A novel definition is proposed for solvent selectivity as the difference between the concentration of the solute in the extract layer, on a solvent-free basis, and the concentration in the raffinate layer.

  18. Application of SH surface acoustic waves for measuring the viscosity of liquids in function of pressure and temperature.

    Science.gov (United States)

    Kiełczyński, P; Szalewski, M; Balcerzak, A; Rostocki, A J; Tefelski, D B

    2011-12-01

    Viscosity measurements were carried out on triolein at pressures from atmospheric up to 650 MPa and in the temperature range from 10°C to 40°C using ultrasonic measuring setup. Bleustein-Gulyaev SH surface acoustic waves waveguides were used as viscosity sensors. Additionally, pressure changes occurring during phase transition have been measured over the same temperature range. Application of ultrasonic SH surface acoustic waves in the liquid viscosity measurements at high pressure has many advantages. It enables viscosity measurement during phase transitions and in the high-pressure range where the classical viscosity measurement methods cannot operate. Measurements of phase transition kinetics and viscosity of liquids at high pressures and various temperatures (isotherms) is a novelty. The knowledge of changes in viscosity in function of pressure and temperature can help to obtain a deeper insight into thermodynamic properties of liquids. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Turbulent temperature fluctuations in liquid metals

    International Nuclear Information System (INIS)

    Lawn, C.J.

    1977-01-01

    Examination of experimental data for the spectral distribution of velocity (u and v) and temperature (theta) fluctuations in the fully turbulent region of heated pipe-flow has suggested a schematic representation which incorporates the essential features. Evidence is cited to suggest that the -vtheta correlation coefficient maintains higher values that the uv coefficient at wave-numbers in the inertial subrange. The theory of Batchelor, Howells and Townsend, and limited evidence from experiments in mercury, then suggests the form of the theta 2 spectra and -vtheta cross-spectra in liquid metals. From this information, a limiting Peclet number is deduced, above which the correlation coefficient of v and theta should be a fairly weak function of Pe alone. An attempt to check this inference from published data for the RMS level of temperature fluctuations, and for the turbulent Prandtl number, proves inconclusive, because many of the correlation coefficients so estimated have values greater than unity. It is concluded that all these results for theta tilde must therefore be in error. However, since there is no evidence of very low correlation coefficients, they almost certainly lie in the range 0.5 multiply/divide 2 over a large proportion of the radius. Thus theta tilde can be estimated for any fluid in which the fluctuations are induced by uniform heating, at least to within a factor of 2, using the analysis presented. (author)

  20. Elementary reaction rate measurements at high temperatures by tunable-laser flash-absorption

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, J.P. [Argonne National Laboratory, IL (United States)

    1993-12-01

    The major objective of this program is to measure thermal rate coefficients and branching ratios of elementary reactions. To perform these measurements, the authors constructed an ultrahigh-purity shock tube to generate temperatures between 1000 and 5500 K. The tunable-laser flash-absorption technique is used to measure the rate of change of the concentration of species which absorb below 50,000 cm{sup {minus}1} e.g.: OH, CH, and CH{sub 3}. This technique is being extended into the vacuum-ultraviolet spectral region where one can measure atomic species e.g.: H, D, C, O, and N; and diatomic species e.g.: O{sub 2}, CO, and OH.

  1. Temperature dependence of three-point correlation functions of viscous liquids: the case of glycerol

    Energy Technology Data Exchange (ETDEWEB)

    Dalle-Ferrier, Cecile; Eibl, Stefan; Alba-Simionesco, Christiane [Laboratoire de Chimie Physique, UMR 8000, Batiment 349, Universite Paris-Sud, 91405 Orsay (France); Pappas, Catherine [BENSC, Hahn-Meitner-Institute, HMI Berlin, Glienicker Strasse 100, D-14109 Berlin (Germany)], E-mail: cecile.dalle-ferrier@lcp.u-psud.fr

    2008-12-10

    What causes the dramatic slowing down of flow and relaxation that leads to glass formation in liquids as temperature decreases is hardly understood so far and is the subject of intensive research work. It is tempting to ascribe the strong temperature dependence of the dynamics, irrespective of molecular details, to a collective or cooperative behavior characterized by a length scale that grows as one approaches the glass transition. To access this length experimentally, we use the recently introduced three-point dynamic susceptibility, from which the number of molecules dynamically correlated during the structural relaxation, N{sub corr}, can be extracted. The three-point functions are related to the sensitivity of the averaged two-time dynamics to external control parameters, such as temperature and density. We studied N{sub corr} values in an important temperature range for a large number of liquids, and found that it systematically grows when approaching the glass transition. Here we specially emphasize the case of glycerol for which we combined dielectric and neutron spin echo spectroscopy to cover more than 16 decades in relaxation time.

  2. Determination of lead at trace levels in mussel and sea water samples using vortex assisted dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry.

    Science.gov (United States)

    Erarpat, Sezin; Özzeybek, Gözde; Chormey, Dotse Selali; Bakırdere, Sezgin

    2017-12-01

    In this study, dispersive liquid-liquid microextraction (DLLME) and slotted quartz tube (SQT) were coupled to flame atomic absorption spectrometry (FAAS) to increase the sensitivity of lead. Conditions such as the formation of the lead-dithizone complex, efficiency of the DLLME method and the output of the SQT were systematically optimized to improve the detection limit for the analyte. The conventional FAAS system was improved upon by about 3.0 times with SQT-FAAS, 32 times with DLLME-FAAS and 142 times with DLLME-SQT-FAAS. The method was applicable over a wide linear range (10-500 μg L -1 ). The limit of detection (LOD) determined by DLLME-SQT-FAAS for seawater and mussel were 2.7 μg L -1 and 270 μg kg -1 , respectively. The percent recoveries obtained for mussel and seawater samples (spiked at 20 and 50 μg L -1 ) were 95-96% and 98-110%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Mass-controlled capillary viscometer for a Newtonian liquid: Viscosity of water at different temperatures

    Science.gov (United States)

    Digilov, Rafael M.; Reiner, M.

    2007-03-01

    The operation principle of the mass-controlled capillary viscometer is presented for a Newtonian liquid. The derived equation for the temporal changes of the mass in a liquid column draining under gravity through a discharge capillary tube accounts self-consistently for the inertial convective term associated with the acceleration effect. The viscosity of water measured at different temperatures using the new approach is in good agreement with literature data.

  4. Gas-liquid interface of room-temperature ionic liquids.

    Science.gov (United States)

    Santos, Cherry S; Baldelli, Steven

    2010-06-01

    The organization of ions at the interface of ionic liquids and the vacuum is an ideal system to test new ideas and concepts on the interfacial chemistry of electrolyte systems in the limit of no solvent medium. Whilst electrolyte systems have numerous theoretical and experimental methods used to investigate their properties, the ionic liquids are relatively new and our understanding of the interfacial properties is just beginning to be explored. In this critical review, the gas-liquid interface is reviewed, as this interface does not depend on the preparation of another medium and thus produces a natural interface. The interface has been investigated by sum frequency generation vibrational spectroscopy and ultra-high vacuum techniques. The results provide a detailed molecular-level view of the surface composition and structure. These have been complemented by theoretical studies. The combinations of treatments on this interface are starting to provide a somewhat convergent description of how the ions are organized at this neat interface (108 references).

  5. Temperature-dependent absorption cross-section measurements of 1-butene (1-C4H8) in VUV and IR

    KAUST Repository

    Es-sebbar, Et-touhami; Bé nilan, Yves; Farooq, Aamir

    2013-01-01

    synchrotron radiation as a tunable VUV light source. Fourier Transform Infrared (FTIR) spectroscopy is employed to measure absorption cross-section and band strengths in the IR region between 1.54 and 25μm (~6500-400cm-1). The measured room-temperature VUV

  6. Room-temperature solid phase ionic liquid (RTSPIL) coated Ω-transaminases: Development and application in organic solvents

    DEFF Research Database (Denmark)

    Grabner, B.; Nazario, M. A.; Gundersen, M. T.

    2018-01-01

    ω-Transaminases ATA-40, ATA-47 and ATA-82P were coated with room-temperature solid phase ionic liquids (RTSPILs) by means of three methods, melt coating, precipitation coating, and co‐lyophilization, and showed increased stability in all of the five tested organic solvents. Co‐lyophilization and ......ω-Transaminases ATA-40, ATA-47 and ATA-82P were coated with room-temperature solid phase ionic liquids (RTSPILs) by means of three methods, melt coating, precipitation coating, and co‐lyophilization, and showed increased stability in all of the five tested organic solvents. Co...

  7. Review on Carbon Dioxide Absorption by Choline Chloride/Urea Deep Eutectic Solvents

    Directory of Open Access Journals (Sweden)

    Rima J. Isaifan

    2018-01-01

    Full Text Available In the recent past few years, deep eutectic solvents (DESs were developed sharing similar characteristics to ionic liquids but with more advantageous features related to preparation cost, environmental impact, and efficiency for gas separation processes. Amongst many combinations of DES solvents that have been prepared, reline (choline chloride as the hydrogen bond acceptor mixed with urea as the hydrogen bond donor was the first DES synthesized and is still the one with the lowest melting point. Choline chloride/urea DES has proven to be a promising solvent as an efficient medium for carbon dioxide capture when compared with amine alone or ionic liquids under the same conditions. This review sheds light on the preparation method, physical and chemical characteristics, and the CO2 absorption capacity of choline chloride/urea DES under different temperatures and pressures reported up to date.

  8. Frequency and Temperature Dependence of Fabrication Parameters in Polymer Dispersed Liquid Crystal Devices

    Directory of Open Access Journals (Sweden)

    Juan C. Torres

    2014-05-01

    Full Text Available A series of polymer dispersed liquid crystal devices using glass substrates have been fabricated and investigated focusing on their electrical properties. The devices have been studied in terms of impedance as a function of frequency. An electric equivalent circuit has been proposed, including the influence of the temperature on the elements into it. In addition, a relevant effect of temperature on electrical measurements has been observed.

  9. Frequency and Temperature Dependence of Fabrication Parameters in Polymer Dispersed Liquid Crystal Devices

    Science.gov (United States)

    Torres, Juan C.; Vergaz, Ricardo; Barrios, David; Sánchez-Pena, José Manuel; Viñuales, Ana; Grande, Hans Jürgen; Cabañero, Germán

    2014-01-01

    A series of polymer dispersed liquid crystal devices using glass substrates have been fabricated and investigated focusing on their electrical properties. The devices have been studied in terms of impedance as a function of frequency. An electric equivalent circuit has been proposed, including the influence of the temperature on the elements into it. In addition, a relevant effect of temperature on electrical measurements has been observed. PMID:28788632

  10. Reversible physical absorption of SO2 by ionic liquids

    DEFF Research Database (Denmark)

    Huang, Jun; Riisager, Anders; Fehrmann, Rasmus

    2006-01-01

    Ionic liquids can reversibly absorb large amounts of molecular SO2 gas under ambient conditions with the gas captured in a restricted configuration, possibly allowing SO2 to probe the internal cavity structures in ionic liquids besides being useful for SO2 removal in pollution control....

  11. Contribution to the characterization of room temperature ionic liquids under ionizing irradiation

    International Nuclear Information System (INIS)

    Le Rouzo, G.; Lamouroux, Ch.; Moutiers, G.

    2010-01-01

    Room-Temperature Ionic Liquids are potentially interesting for nuclear fuel treatment. Within this framework, ionic liquids stability towards ionizing radiations (α, β or γ) is determining their potential application. The aim of this work is to assess a better understanding of ionic liquids behaviour under radiolysis. Ionic liquids chosen in these studies are constituted with BuMeIm + (or Bu 3 MeN + ) cation associated with various anions: Tf 2 N - , TfO - , PF 6 - and BF 4 - . Moreover, development of suitable chemical analysis tools crucial for characterization of these compounds has been realized. Ionic liquids stability has been mainly studied under γ irradiation, but also under electron beam or heavy particles irradiations. Ionic liquids degradation under radiolysis has been determined with two complementary approaches. The first one aims at understanding radio-induced degradation mechanisms with radical species analysis by Electron Paramagnetic Resonance spectroscopy (EPR). The second one aims at characterizing stable radiolysis products formed in liquid and gaseous phases. Studies were conducted with several analytical techniques: Electro Spray Ionisation Mass Spectrometry (ESI-MS), High Pressure Liquid Chromatography (HPLC, HPLC/UV-VIS, HPLC/ESI-MS), Gas Analysis Mass Spectrometry (Gas MS) and Gas Chromatography hyphenated with Mass Spectrometry (GC/MS). Firstly, the ionic liquid [Bu 3 MeIm][Tf 2 N] has been studied under γ irradiation. Radiolytic stability has been quantitatively assessed for high doses of radiations and a proposal of degradation scheme has been proposed on the basis of radio-induced radicals and radiolysis products analysis. Those data have been compared to those obtained for the γ radiolysis of the ionic liquid [Bu 3 MeN][Tf 2 N], enabling to assess cation influence on ionic liquids radiolysis. Secondly, degradation under γ irradiation of ionic liquids [BuMeIm][X] (X - Tf 2 N - , TfO - , PF 6 - , BF 4 - ) has been quantitatively

  12. Investigation of ammonia/water hybrid absorption/compression heat pumps for heat supply temperatures above 100 °C

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Reinholdt, Lars; Markussen, Wiebke Brix

    2014-01-01

    The hybrid absorption/compression heat pump (HACHP) using ammonia-water as working fluid is a promising technology for development of a high temperature industrial heat pump. This is due to two properties inherent to the use of zeotropic mixtures: non-isothermal phase change and reduced vapour...... using these components. A technically and economically feasible solution is defined as one that satisfies constraints on the coefficient of performance (COP), low and high pressure, compressor discharge temperature and volumetric heat capacity. The ammonia mass fraction of the rich solution...

  13. Pulse radiolysis studies on liquid alkanes and related polymers

    International Nuclear Information System (INIS)

    Tagawa, S.; Hayashi, N.; Yoshida, Y.; Washio, M.; Tabata, Y.

    1989-01-01

    Absorption spectra of alkane radical cations, alkane excited states, and alkyl radicals and electrons in irradiated neat liquid alkanes at room temperature were assigned on subnanosecond and nanosecond time scale after an electron pulse. Two broad visible and near-infrared absorption bands of alkane excited states and radical cations, and UV absorption band of alkyl radicals was observed in neat n-alkanes. In neat cyclohezane and trans-decalin, very broad visible absorption band mainly due to alkane excited states and UV absorption band of alkyl radicals were observed. In neat neopentane and isooctane, visible absorption bands were not observed, although UV absorption bands of alkyl radicals were observed. The wavelengths of absorptive peaks of alkane radical cations and excited states become longer with increasing the number of carbon atoms of n-alkanes. The lifetimes of alkane radical cations become shorter with decreasing the number of carbon atoms of n-alkanes and are shorter than those of electrons in neat alkanes. The main processes of the alkyl radical formation finish within the time resolution of our system (about 20 ps). The alkyl radicals are produced mainly from excited radicals cations and partly from higher excited states, the lowest excited states, radical cations, and thermal hydrogen atoms, In irradiated ethylene-propylene copolymers, broad absorption bands of excited states and tail parts of absorption bands of radical cations and electrons were observed in visible and near-infrared region, although UV absorption of alkyl radicals was not confirmed lack of transparency of polymer films. (author)

  14. Evaporation of a liquid drop on a hot liquid surface, (1)

    International Nuclear Information System (INIS)

    Iida, Yoshihiro; Takashima, Takeo

    1980-01-01

    As for the phenomena occurring when two kinds of liquid at different temperature come in contact, the clarification of the basic, general matters of the phenomena has not been made yet. Such situation has been caused by the facts that the detailed observation of the aspect in liquid-liquid contact becomes impossible as the disturbance on the interface becomes violent, and it is difficult to obtain the quantitative data and to change temperature difference largely in practice. In this study, liquid drops were dropped on the free surface of another liquid at the temperature higher than the saturation temperature of the dropping liquid, and it was attempted to obtain the basic knowledge concerning the general behavior at the time of liquid-liquid contact by determining the aspect of evaporation and its change and evaporation time. For this experiment, the silicone oil with four different kinematic viscosity was used as the high temperature liquid, and n-pentane and dichloromethane soluble in the mother liquid, and acetone and methyl alcohol insoluble in the mother liquid were used as the liquid drops. The experimental apparatuses and method and the results are reported. The evaporation time curves presented lying S-shape basically, similarly to the evaporation on solid surfaces. The point of maximum evaporation time and the point of maximum heat transfer rate existed. (J.P.N.)

  15. Novel room temperature ionic liquid for fluorescence enhancement of Eu3+ and Tb3+

    International Nuclear Information System (INIS)

    Shyamala Devi, V.; Maji, S.; Viswanathan, K.S.

    2011-01-01

    The newly prepared ionic liquid, 1-butyl-3-methylimidazolium benzoate, ([bmim][BA]), was found to enhance the fluorescence of Eu 3+ and Tb 3+ . The fluorescence enhancement resulted from a sensitization of the lanthanide fluorescence by the benzoate anion of the ionic liquid, [bmim][BA], and a reduction in the non-radiative channels in the non-aqueous environment provided by the ionic liquid. However, the fluorescence enhancement of the lanthanides in the ionic liquid was limited due to the operation of the inner filter effect, which resulted from the strong absorption of the benzoate. The inner filter effect was minimized by observing the Eu 3+ fluorescence using a front face geometry and also by diluting the lanthanide-[bmim][BA] system, using another ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([bmim][Tf 2 N]), as a solvent. In the case of Tb 3+ , the emission from the lanthanide was masked by the strong emission from the ionic liquid in the region 450-580 nm. The long lived Tb 3+ emission was therefore observed using delayed gated detection, where an appropriate delay was used to discriminate against the short lived emission from the ionic liquid. The large fluorescence enhancement due to ligand sensitized fluorescence observed with [bmim][BA] diluted in [bmim][Tf 2 N], leads to nanomolar detection of the lanthanides. This is, to the best of our knowledge, the first report of an ionic liquid being employed for ligand sensitized fluorescence enhancement of lanthanides. - Research highlights: →The use of an ionic liquid to enhance the fluorescence of lanthanides, Eu 3+ and Tb 3+ is discussed in this paper. → This study represents the first report of the use of a tailored ionic liquid for the purposes of fluorescence enhancement. → The fluorescence enhancement is achieved both a process of ligand sensitization, as well as reducing the non-radiative decay channels. → The first point is achieved by the use of an anion capable

  16. Viscosity of komatiite liquid at high pressure and temperature

    Science.gov (United States)

    O Dwyer, L.; Lesher, C. E.; Wang, Y.

    2006-12-01

    The viscosities of komatiite liquids at high pressures and temperatures are being investigated by the in-situ falling sphere technique, using the T-25 multianvil apparatus at the GSECARS 13 ID-D beamline at the Advanced Photon Source, ANL. The refractory and fluid nature of komatiite and other ultramafic liquids relevant to the Earth's deep interior, presents unique challenges for this approach. To reach superliquidus temperatures we use a double reservoir configuration, where marker spheres are placed at the top of both a main melt reservoir and an overlying reservoir containing a more refractory composition. Using this approach, we have successfully measured the viscosity of a komatiite from Gorgona Island (GOR-94-29; MgO - 17.8 wt.%; NBO/T = 1.6) up to 6 GPa and 1900 K. Under isothermal conditions, viscosity increases with pressure, consistent with the depolymerized nature of the komatiite. At 1900 K, viscosity increases from 1.5 (+- 0.3) Pa s at 3.5 GPa to 3.4 (+- 0.3) Pa s at 6 GPa, corresponding to an activation volume of 2.2 cm3/mol. At high pressures, the viscosities of Gorgona Island komatiite melt are an order of magnitude higher than those measured by Liebske et al. (2005, EPSL, v. 240) for peridotite melt (MgO 37.1 wt.%; NBO/T = 2.5), and similar in magnitude to molten diopside (NBO/T = 2) (Reid et al. 2003, PEPI, v. 139). The positive pressure dependence is consistent with the reduction in interatomic space diminishing the free volume of the liquid as it is compressed. Above 6 GPa the free volume reduction may become less important with the production of high-coordinated network formers, as attributed to the reversal of the pressure dependence of viscosity for peridotite melt at ~8.5 GPa and diopside melt at ~10 GPa. Experiments at higher pressures are underway to determine if a similar viscosity maximum occurs for komatiite melt and whether its pressure is greater than 10 GPa, as suggested by the data for peridotite and diopside melts.

  17. Design and Control of High Temperature PEM Fuel Cell Systems using Methanol Reformers with Air or Liquid Heat Integration

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Kær, Søren Knudsen; Sahlin, Simon Lennart

    2013-01-01

    The present work describes the ongoing development of high temperature PEM fuel cell systems fuelled by steam reformed methanol. Various fuel cell system solutions exist, they mainly differ depending on the desired fuel used. High temperature PEM (HTPEM) fuel cells offer the possibility of using...... methanol is converted to a hydrogen rich gas with CO2 trace amounts of CO, the increased operating temperatures allow the fuel cell to tolerate much higher CO concentrations than Nafion-based membranes. The increased tolerance to CO also enables the use of reformer systems with less hydrogen cleaning steps...... liquid fuels such as methanol, due to the increased robustness of operating at higher temperatures (160-180oC). Using liquid fuels such as methanol removes the high volume demands of compressed hydrogen storages, simplifies refueling, and enables the use of existing fuel distribution systems. The liquid...

  18. CO2 sorption by supported amino acid ionic liquids

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention concerns the absorption and desorption behaviour of carbon dioxide (CO2) using ionic liquids derived from amino acids adsorbed on porous carrier materials.......The present invention concerns the absorption and desorption behaviour of carbon dioxide (CO2) using ionic liquids derived from amino acids adsorbed on porous carrier materials....

  19. Absorption of hydrogen in vanadium, enhanced by ion bombardment; Ionenbeschussunterstuetzte Absorption des Wasserstoffs in Vanadium

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, H.; Lammers, M. [Inst. fuer Technologie- und Wissenstransfer, Soest (Germany); Mueller, K.H. [Inst. fuer Technologie- und Wissenstransfer, Soest (Germany)]|[Paderborn Univ. (Gesamthochschule), Soest (Germany). Fachbereich 16 - Elektrische Energietechnik; Kiss, G.; Kemeny, Z. [Technical Univ. Budapest (Hungary)

    1998-12-31

    Prior to hydrogen implantation into vanadium, the vanadium specimen usually is exposed to an activation process and is then heated at 1 atm hydrogen to temperatures between 500 and 600 C, subsequently cooled down in several steps. Within this temperature range, hydrogen solubility increases with declining temperature. A decisive factor determining hydrogen absorption is the fact that at temperatures above 250 C, oxygen desorbs from the material surface and thus no longer inhibits hydrogen absorption. Therefore a different approach was chosen for the experiments reported: Hydrogen absorption under UHV conditions at room temperature. After the usual activation process, the vanadium surface was cleaned by 5 keV Ar{sup +} ion bombardment. Thus oxygen absorption at the specimen surface (and new reactions with oxygen from the remaining gas) could be avoided, or removed. By means of thermal desorption mass spectrometry (TDMS), hydrogen absorption as a function of argon ion dose was analysed. TDMS measurements performed for specimens treated by ion bombardment prior to H{sup 2} exposure showed two H{sup 2} desorption peaks, in contrast to the profiles measured with specimens not exposed to ion bombardment. It is assumed that the ion bombardment disturbs the crystal structure so that further sites for hydrogen absorption are produced. (orig./CB) [Deutsch] Bei der Beladung von Vandium mit Wasserstoff wird ueblicherweise die Probe nach einer Aktivierungsprozedur bei 1 atm Wasserstoff auf Temperaturen im Bereich von 500 bis 600 C hochgeheizt und danach schrittweise abgekuehlt. In diesem Temperaturbereich nimmt die Wasserstoffloeslichkeit mit abnehmender Temperatur zu. Entscheidend fuer die Beladung ist aber auch die Tatsache, dass bei Temperaturen groesser 250 C Sauerstoff von der Oberflaeche desorbiert und dadurch die Absorption von Wasserstoff nicht mehr blockieren kann. Im Rahmen der hier beschriebenen Untersuchungen sollte die Wasserstoffbeladung unter UHV-Bedingungen bei

  20. The influence of temperature, viscosity and pH on the relaxation time T1 in flowing liquids

    International Nuclear Information System (INIS)

    Toczylowska, B.

    1995-01-01

    The designed and constructed at the Institute of Biocybernetics and Biomedical Engineering facility for the relaxation time (T 1 ) measurements of liquids flow has been presented. The influence of temperature, viscosity and pH has been determined for several liquids, especially physiological fluids

  1. Experimental studies on the krypton absorption in liquid CO2 (KALC) process

    International Nuclear Information System (INIS)

    Glass, R.W.; Beaujean, H.W.R.; Fowler, V.L.; Gilliam, T.M.; Inman, D.J.; Levins, D.M.

    1976-01-01

    Results are presented for a series of experiments to quantify krypton removal from simulated High-Temperature Gas-Cooled Reactor reprocessing off-gas by the KALC process. The Experimental Engineering Section Off-Gas Decontamination Facility used in the campaign provides engineering-scale experiments with nominal gas and liquid flows of 5 scfm and 0.5 gpm respectively. Equilibrium and nonequilibrium mass transfer experiments for the CO 2 --O 2 --Kr system are described. Data analysis indicates values of HTU for krypton on the order of 0.5 ft for decontamination factors from 100 to 10,000. Recent flooding information for the packed columns is combined with previous data and is shown to be well represented by an empirical flooding equation

  2. Observation of magnetostatic wave electron absorption in ferrite-high temperature superconductor structure. Nablyudenie ehlektronnogo pogloshcheniya magnitostaticheskikh voln v strukture ferrit-vysokotemperaturnyj sverkhprovodnik

    Energy Technology Data Exchange (ETDEWEB)

    Anfinogenov, V B; Gulyaev, Yu V; Zil' berman, P E; Kotelyanskij, I M; Polzikova, N I; Sukhanov, A A [AN SSSR, Moscow (USSR). Inst. Radiotekhniki i Ehlektroniki

    1989-07-26

    Conditions for magneto-static wave (MSW) propagation in laminar structures ferrite-high-temperature superconductor (YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}) and effect of transition into superconducting state under the temperature drop on these conditions are investigated. MSW electron absorption effrect in such structures (strongly dependent on the temperature) is detected and its interpretation is given.

  3. Temperature modulation of the visible and near infrared absorption and scattering coefficients of human skin.

    Science.gov (United States)

    Khalil, Omar S; Yeh, Shu-Jen; Lowery, Michael G; Wu, Xiaomao; Hanna, Charles F; Kantor, Stanislaw; Jeng, Tzyy-Wen; Kanger, Johannes S; Bolt, Rene A; de Mul, Frits F

    2003-04-01

    We determine temperature effect on the absorption and reduced scattering coefficients (mu(a) and mu(s)(')) of human forearm skin. Optical and thermal simulation data suggest that mu( a) and mu(s)(') are determined within a temperature-controlled depth of approximately 2 mm. Cutaneous mu(s)(') change linearly with temperature. Change in mu(a) was complex and irreversible above body normal temperatures. Light penetration depth (delta) in skin increased on cooling, with considerable person-to-person variations. We attribute the effect of temperature on mu(s)(') to change in refractive index mismatch, and its effect on mu(a) to perfusion changes. The reversible temperature effect on mu (s)(' ) was maintained during more than 90 min. contact between skin and the measuring probe, where temperature was modulated between 38 and 22 degrees C for multiple cycles While temperature modulated mu(s)(' ) instantaneously and reversibly, mu(a) exhibited slower response time and consistent drift. There was a statistically significant upward drift in mu(a) and a mostly downward drift in mu( s)(') over the contact period. The drift in temperature-induced fractional change in mu(s)(') was less statistically significant than the drift in mu(s)('). Deltamu( s)(') values determined under temperature modulation conditions may have less nonspecific drift than mu(s)(') which may have significance for noninvasive determination of analytes in human tissue.

  4. Pressure Swing Absorption Device and Process for Separating CO{sub 2} from Shifted Syngas and its Capture for Subsequent Storage

    Energy Technology Data Exchange (ETDEWEB)

    Sirkar, Kamalesh; Jie, Xingming; Chau, John; Obuskovic, Gordana

    2013-03-31

    Using the ionic liquid (IL) 1-butyl-3-methylimidazolium dicyanamide ([bmim][DCA]) as the absorbent on the shell side of a membrane module containing either a porous hydrophobized ceramic tubule or porous hydrophobized polyether ether ketone (PEEK) hollow fiber membranes, studies for CO{sub 2} removal from hot simulated pre-combustion shifted syngas were carried out by a novel pressure swing membrane absorption (PSMAB) process. Helium was used as a surrogate for H{sub 2} in a simulated shifted syngas with CO{sub 2} around 40% (dry gas basis). In this cyclic separation process, the membrane module was used to achieve non-dispersive gas absorption from a high-pressure feed gas (689-1724 kPag; 100-250 psig) at temperatures between 25-1000C into a stationary absorbent liquid on the module shell side during a certain part of the cycle followed by among other cycle steps controlled desorption of the absorbed gases from the liquid in the rest of the cycle. Two product streams were obtained, one He-rich and the other CO{sub 2}-rich. Addition of polyamidoamine (PAMAM) dendrimer of generation 0 to IL [bmim][DCA] improved the system performance at higher temperatures. The solubilities of CO{sub 2} and He were determined in the ionic liquid with or without the dendrimer in solution as well as in the presence or absence of moisture; polyethylene glycol (PEG) 400 was also studied as a replacement for the IL. The solubility selectivity of the ionic liquid containing the dendrimer for CO{sub 2} over helium was considerably larger than that for the pure ionic liquid. The solubility of CO{sub 2} and CO{sub 2}-He solubility selectivity of PEG 400 and a solution of the dendrimer in PEG 400 were higher than the corresponding ones in the IL, [bmim][DCA]. A mathematical model was developed to describe the PSMAB process; a numerical solution of the governing equations described successfully the observed performance of the PSMAB process for the pure ionic liquid-based system.

  5. In-situ Density and Thermal Expansion Measurements of Fe and Fe-S Alloying Liquids Under Planetary Core Conditions

    Science.gov (United States)

    Jing, Z.; Chantel, J.; Yu, T.; Sakamaki, T.; Wang, Y.

    2015-12-01

    Liquid iron is likely the dominant constituent in the cores of terrestrial planets and icy satellites such as Earth, Mars, Mercury, the Moon, Ganymede, and Io. Suggested by geophysical and geochemical observations, light elements such as S, C, Si, etc., are likely present in planetary cores. These light elements can significantly reduce the density and melting temperature of the Fe cores, and hence their abundances are crucial to our understanding of the structure and thermal history of planetary cores, as well as the generation of intrinsic magnetic fields. Knowledge on the density of Fe-light element alloying liquids at high pressures is critical to place constraints on the composition of planetary cores. However, density data on liquid Fe-light element alloys at core pressures are very limited in pressure and composition and are sometimes controversial. In this study, we extend the density dataset for Fe-rich liquids by measuring the density of Fe, Fe-10wt%S, Fe-20wt%S, Fe-27wt%S, and FeS liquids using the X-ray absorption technique in a DIA-type multianvil apparatus up to 7 GPa and 2173 K. An ion chamber (1D-detector) and a CCD camera (2D-detector) were used to measure intensities of transmitted monochromatic X-rays through molten samples, with the photon energy optimized at 40 keV. The densities were then determined from the Beer-Lambert law using the mass absorption coefficients, calibrated by solid standards using X-ray diffraction. At each pressure, density measurements were conducted at a range of temperatures above the liquidus of the samples, enabling the determination of thermal expansion. Combined with our previous results on the sound velocity of Fe and Fe-S liquids at high pressures (Jing et al., 2014, Earth Planet. Sci. Lett. 396, 78-87), these data provide tight constraints on the equation of state and thermodynamic properties such as the adiabatic temperature gradient for Fe-S liquids. We will discuss these results with implications to planetary

  6. Gamma absorption meter

    International Nuclear Information System (INIS)

    Dincklage, R.D. von.

    1984-01-01

    The absorption meter consists of a radiation source, a trough for the absorbing liquid and a detector. It is characterized by the fact that there is a foil between the detector and the trough, made of a material whose binding energy of the K electrons is a little greater than the energy of the photons emitted by the radiation source. The source of radiation and foil are replaceable. (orig./HP) [de

  7. Room temperature ferromagnetism and absorption red-shift in nitrogen-doped TiO{sub 2} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Gómez-Polo, C., E-mail: gpolo@unavarra.es [Departamento de Física, Universidad Pública de Navarra, Campus de Arrosadia, 31006 Pamplona (Spain); Larumbe, S. [Departamento de Física, Universidad Pública de Navarra, Campus de Arrosadia, 31006 Pamplona (Spain); Monge, M. [Departamento de Química, Universidad de la Rioja, Centro de Investigación en Síntesis Química (CISQ), Complejo Científico Tecnológico, 26006 Logroño (Spain)

    2014-11-05

    Highlights: • N-doped TiO{sub 2} anatase nanoparticles were obtained by sol–gel. • The nanoparticle size, controlled by the N doping, determines lattice parameters. • Correlation between room temperature ferromagnetism and absorption red-shift. • Oxygen vacancies reinforce both phenomena. • Metal transition impurities contribute to the room temperature ferromagnetism. - Abstract: In this work, room-temperature ferromagnetism and the red-shift of the optical absorption is analyzed in nitrogen doped TiO{sub 2} semiconductor nanoparticles. The nanoparticles were synthesized by the sol–gel method using urea as the nitrogen source. Titanium Tetraisopropoxide (TTIP) was employed as the alkoxyde precursor and dissolved in ethanol. The as prepared gels were dried and calcined in air at 300 °C. Additionally, post-annealing treatments under vacuum atmosphere were performed to modify the oxygen stoichiometry of the samples. The anatase lattice parameters, analyzed by means of powder X-ray diffractometry, depend on the nanometer grain size of the nanoparticles (increase and decrease, respectively, of the tetragonal a and c lattice parameters with respect to the bulk values). The diffuse reflectance ultraviolet–visible (UV–Vis) absorbance spectra show a clear red-shift as consequence of the nitrogen and the occurrence of intragap energy levels. The samples display ferromagnetic features at room temperature that are reinforced with the nitrogen content and after the post annealings in vacuum. The results indicate a clear correlation between the room temperature ferromagnetism and the shift of the absorbance spectrum. In both phenomena, oxygen vacancies (either induced by the nitrogen doping or by the post vacuum annealings) play a dominant role. However, we conclude the existence of very low concentration of diluted transition metal impurities that determine the room ferromagnetic response (bound magnetic polaron BMP model). The contraction of the c soft axis

  8. Accurate measurements and temperature dependence of the water vapor self-continuum absorption in the 2.1 μm atmospheric window

    International Nuclear Information System (INIS)

    Ventrillard, I.; Romanini, D.; Mondelain, D.; Campargue, A.

    2015-01-01

    In spite of its importance for the evaluation of the Earth radiative budget, thus for climate change, very few measurements of the water vapor continuum are available in the near infrared atmospheric windows especially at temperature conditions relevant for our atmosphere. In addition, as a result of the difficulty to measure weak broadband absorption signals, the few available measurements show large disagreements. We report here accurate measurements of the water vapor self-continuum absorption in the 2.1 μm window by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) for two spectral points located at the low energy edge and at the center of the 2.1 μm transparency window, at 4302 and 4723 cm −1 , respectively. Self-continuum cross sections, C S , were retrieved with a few % relative uncertainty, from the quadratic dependence of the spectrum base line level measured as a function of water vapor pressure, between 0 and 16 Torr. At 296 K, the C S value at 4302 cm −1 is found 40% higher than predicted by the MT-CKD V2.5 model, while at 4723 cm −1 , our value is 5 times larger than the MT-CKD value. On the other hand, these OF-CEAS C S values are significantly smaller than recent measurements by Fourier transform spectroscopy at room temperature. The temperature dependence of the self-continuum cross sections was also investigated for temperatures between 296 K and 323 K (23-50 °C). The derived temperature variation is found to be similar to that derived from previous Fourier transform spectrometer (FTS) measurements performed at higher temperatures, between 350 K and 472 K. The whole set of measurements spanning the 296-472 K temperature range follows a simple exponential law in 1/T with a slope close to the dissociation energy of the water dimer, D 0 ≈ 1100 cm −1

  9. Thermodynamic Analysis and Optimization of a High Temperature Triple Absorption Heat Transformer

    Science.gov (United States)

    Khamooshi, Mehrdad; Yari, Mortaza; Egelioglu, Fuat; Salati, Hana

    2014-01-01

    First law of thermodynamics has been used to analyze and optimize inclusively the performance of a triple absorption heat transformer operating with LiBr/H2O as the working pair. A thermodynamic model was developed in EES (engineering equation solver) to estimate the performance of the system in terms of the most essential parameters. The assumed parameters are the temperature of the main components, weak and strong solutions, economizers' efficiencies, and bypass ratios. The whole cycle is optimized by EES software from the viewpoint of maximizing the COP via applying the direct search method. The optimization results showed that the COP of 0.2491 is reachable by the proposed cycle. PMID:25136702

  10. Thermodynamic Analysis and Optimization of a High Temperature Triple Absorption Heat Transformer

    Directory of Open Access Journals (Sweden)

    Mehrdad Khamooshi

    2014-01-01

    Full Text Available First law of thermodynamics has been used to analyze and optimize inclusively the performance of a triple absorption heat transformer operating with LiBr/H2O as the working pair. A thermodynamic model was developed in EES (engineering equation solver to estimate the performance of the system in terms of the most essential parameters. The assumed parameters are the temperature of the main components, weak and strong solutions, economizers’ efficiencies, and bypass ratios. The whole cycle is optimized by EES software from the viewpoint of maximizing the COP via applying the direct search method. The optimization results showed that the COP of 0.2491 is reachable by the proposed cycle.

  11. Active chemisorption sites in functionalized ionic liquids for carbon capture.

    Science.gov (United States)

    Cui, Guokai; Wang, Jianji; Zhang, Suojiang

    2016-07-25

    Development of novel technologies for the efficient and reversible capture of CO2 is highly desired. In the last decade, CO2 capture using ionic liquids has attracted intensive attention from both academia and industry, and has been recognized as a very promising technology. Recently, a new approach has been developed for highly efficient capture of CO2 by site-containing ionic liquids through chemical interaction. This perspective review focuses on the recent advances in the chemical absorption of CO2 using site-containing ionic liquids, such as amino-based ionic liquids, azolate ionic liquids, phenolate ionic liquids, dual-functionalized ionic liquids, pyridine-containing ionic liquids and so on. Other site-containing liquid absorbents such as amine-based solutions, switchable solvents, and functionalized ionic liquid-amine blends are also investigated. Strategies have been discussed for how to activate the existent reactive sites and develop novel reactive sites by physical and chemical methods to enhance CO2 absorption capacity and reduce absorption enthalpy. The carbon capture mechanisms of these site-containing liquid absorbents are also presented. Particular attention has been paid to the latest progress in CO2 capture in multiple-site interactions by amino-free anion-functionalized ionic liquids. In the last section, future directions and prospects for carbon capture by site-containing ionic liquids are outlined.

  12. Structural crossover in a supercooled metallic liquid and the link to a liquid-to-liquid phase transition

    Energy Technology Data Exchange (ETDEWEB)

    Lan, S.; Ma, J. L.; Fan, J. [Department of Physics and Material Science, City University of Hong Kong 83 Tat Chee Ave., Kowloon (Hong Kong); Blodgett, M.; Kelton, K. F. [Department of Physics and Institute of Materials Science and Engineering, Washington University One Brookings Drive, St. Louis, Missouri 63130-4899 (United States); Wang, X.-L., E-mail: xlwang@cityu.edu.hk [Department of Physics and Material Science, City University of Hong Kong 83 Tat Chee Ave., Kowloon (Hong Kong); City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057 (China)

    2016-05-23

    Time-resolved synchrotron measurements were carried out to capture the structure evolution of an electrostatically levitated metallic-glass-forming liquid during free cooling. The experimental data shows a crossover in the liquid structure at ∼1000 K, about 115 K below the melting temperature and 150 K above the crystallization temperature. The structure change is characterized by a dramatic growth in the extended-range order below the crossover temperature. Molecular dynamics simulations have identified that the growth of the extended-range order was due to an increased correlation between solute atoms. These results provide structural evidence for a liquid-to-liquid-phase-transition in the supercooled metallic liquid.

  13. Consequences of metallic fuel-cladding liquid phase attack during over-temperature transient on fuel element lifetime

    International Nuclear Information System (INIS)

    Lahm, C.E.; Koenig, J.F.; Seidel, B.R.

    1990-01-01

    Metallic fuel elements irradiated in EBR-II at temperatures significantly higher than design, causing liquid phase attack of the cladding, were subsequently irradiated at normal operating temperatures to first breach. The fuel element lifetime was compared to that for elements not subjected to the over-temperature transient and found to be equivalent. 1 ref., 3 figs

  14. Ionic liquids as electrolytes

    International Nuclear Information System (INIS)

    Galinski, Maciej; Lewandowski, Andrzej; Stepniak, Izabela

    2006-01-01

    Salts having a low melting point are liquid at room temperature, or even below, and form a new class of liquids usually called room temperature ionic liquids (RTIL). Information about RTILs can be found in the literature with such key words as: room temperature molten salt, low-temperature molten salt, ambient-temperature molten salt, liquid organic salt or simply ionic liquid. Their physicochemical properties are the same as high temperature ionic liquids, but the practical aspects of their maintenance or handling are different enough to merit a distinction. The class of ionic liquids, based on tetraalkylammonium cation and chloroaluminate anion, has been extensively studied since late 1970s of the XX century, following the works of Osteryoung. Systematic research on the application of chloroaluminate ionic liquids as solvents was performed in 1980s. However, ionic liquids based on aluminium halides are moisture sensitive. During the last decade an increasing number of new ionic liquids have been prepared and used as solvents. The general aim of this paper was to review the physical and chemical properties of RTILs from the point of view of their possible application as electrolytes in electrochemical processes and devices. The following points are discussed: melting and freezing, conductivity, viscosity, temperature dependence of conductivity, transport and transference numbers, electrochemical stability, possible application in aluminium electroplating, lithium batteries and in electrochemical capacitors

  15. High temperature aqueous potassium and sodium phosphate solutions: two-liquid-phase boundaries and critical phenomena, 275-4000C; potential applications for steam generators

    International Nuclear Information System (INIS)

    Marshall, W.L.

    1981-12-01

    Two-liquid-phase boundaries at temperatures between 275 and 400 0 C were determined for potassium phosphate and sodium phosphate aqueous solutions for compositions from 0 to 60 wt % dissolved salt. The stoichiometric mole ratios, K/PO 4 or Na/PO 4 , were varied from 1.00 to 2.12 and from 1.00 to 2.16 for the potassium and sodium systems, respectively. Liquid-vapor critical temperatures were also determined for most of the dilute liquid phases that formed. The minimum temperatures (below which a single solution existed) of two-liquid-phase formation were 360 0 C for the potassium system and 279 0 C for the sodium system at mole ratios of 2.00 and 2.16, respectively. For the sodium system at mole ratios greater than 2.16, solids crystallized at lower temperatures as expected from earlier studies. In contrast, potassium solutions that were explored at mole ratios from 2.12 to 3.16 and at temperatures below 360 0 C did not produce solid phases nor liquid-liquid immiscibilities. Aside from the generally unusual observations of two immiscible liquids in an aqueous inorganic salt system, the results could possibly be applied to the use of phosphate additives in steam power generators. 16 refs

  16. Temperature effects of Mach-Zehnder interferometer using a liquid crystal-filled fiber

    DEFF Research Database (Denmark)

    Ho, Bo-Yan; Su, Hsien-Pin; Tseng, Yu-Pei

    2015-01-01

    We demonstrated a simple and cost-effective method to fabricate all fiber Mach-Zehnder interferometer (MZI) based on cascading a short section of liquid crystal (LC)-filled hollow-optic fiber (HOF) between two single mode fibers by using automatically splicing technique. The transmission spectra...... of the proposed MZI with different LC-infiltrated length were measured and the temperature-induced wavelength shifts of the interference fringes were recorded. Both blue shift and red shift were observed, depending the temperature range. Based on our experimental results, interference fringe was observed...

  17. 4He-impurity effects on normal liquid 3He at low temperatures I - preliminary ideas and calculations

    International Nuclear Information System (INIS)

    Ghassib, H.B.; Chatterjee, S.

    1982-02-01

    The effects of 4 He impurities on the low-temperature properties of normal liquid 3 He are explored. It is argued that these effects should manifest themselves in, among other properties, the liquid structure factor at very low temperatures and momentum transfers, the acoustic impedance near the transition region from the zero- to the first-sound regime, the propagation of sound, the phase diagram, and the magnetic properties - including the magnetokinetic coefficients of the spin-polarized system. Several experiments are suggested to detect these macroscopic manifestations. (author)

  18. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  19. Combined techniques for studying actinide complexes in room temperature ionic liquids

    International Nuclear Information System (INIS)

    Gaillard, C.; Billard, I.; Mekki, S.; Ouadi, A.; Hennig, Ch.; Denecke, M.A.

    2007-01-01

    Room temperature ionic liquids (RTILs) are a new class of solvents. Their main interest is related to their 'green' properties (non-volatile, non-flammable, etc.), but also from the variability of their physico-chemical properties (stability, hydrophobicity, viscosity) as a function of the RTIL cationic and anionic components. In the frame of the nuclear fuel reprocessing, RTILs are particularly attractive in order to improve existing processes or to develop new ones for actinide and lanthanide partitioning, in replacement of toxic solvents used nowadays, for metal electrodeposition or for liquid/liquid extraction by the use of task specific ionic liquids. However, despite the increasing number of publications devoted to ionic liquids, the solvation effects, the solute-solvent and solvent-solvent interactions are still hardly known. These fundamental aspects are of tremendous importance to the understanding of the solvating properties of these new solvents. In this frame, we have undertaken studies on the solvation and complexation of lanthanides (III) and actinides in RTILs, by the use of spectroscopic techniques. Experiments were led in various ionic liquids in order to highlight the role of the anionic part of the RTILs on the reactivity of the studied cations. Results have clearly shown that solvation phenomena in RTILs are not as 'simple' as in classical solvents. The dissolution of a Ln/An salt, even if complete, does not imply dissociation and solvation of the metal cation by the RTILs anions only. The nature of first co-ordination sphere of Ln/An depends on the competition between its counter-anions and the RTIL anions, which, in turn, influence the complexation reaction with other added anions such as chlorides. (authors)

  20. Device for the crystallographic study of substances maintained at liquid nitrogen temperature

    International Nuclear Information System (INIS)

    Pluchery, M.; Debrenne, P.

    1961-01-01

    When a substance to be studied has been submitted to a processing at low temperature, and that no heating can be tolerated between this processing and the X-ray investigation, conventional low temperature devices are difficult to use. Diffraction lines are recorded, as well as Bragg angles between 55 and 88 deg. The authors present a device that allows a sample permanently immersed in liquid nitrogen to be studied, either through its lower part, or as a whole. They describe the operation principle, how a sample is set into place, how measurements are performed. They comment technical characteristics and performance. This device has been used to measure parameters of graphite irradiated at high temperature [fr