WorldWideScience

Sample records for absorption band compared

  1. Enhanced dual-band infrared absorption in a Fabry-Perot cavity with subwavelength metallic grating.

    Science.gov (United States)

    Kang, Guoguo; Vartiainen, Ismo; Bai, Benfeng; Turunen, Jari

    2011-01-17

    The performance of infrared (IR) dual-band detector can be substantially improved by simultaneously increasing IR absorptions for both sensor bands. Currently available methods only provide absorption enhancement for single spectral band, but not for the dual-band. The Fabry-Perot (FP) cavity generates a series of resonances in multispectral bands. With this flexibility, we introduced a novel type of dual-band detector structure containing a multilayer FP cavity with two absorbing layers and a subwavelength-period grating mirror, which is capable of simultaneously enhancing the middle wave infrared (MWIR) and the long wave infrared (LWIR) detection. Compared with the bare-absorption-layer detector (common dual-band detector), the optimized FP cavity can provide about 13 times and 17 times absorption enhancement in LWIR and MWIR bands respectively.

  2. Glucose Absorption by the Bacillary Band of Trichuris muris

    DEFF Research Database (Denmark)

    Hansen, Tina Vicky Alstrup; Hansen, Michael; Nejsum, Peter

    2016-01-01

    of the bacillary band in living worms was explored using a fluorescent glucose analogue (6-NBDG) and confocal microscopy. To study the absorptive function of the bacillary band in relation to 6-NBDG, the oral uptake was minimised or excluded by sealing the oral cavity with glue and agarose. Principal Findings....... Conclusions/Significance Trichuris muris is dependent on glucose for viability in vitro, and the bacillary band has an absorptive function in relation to 6-NBDG, which accumulates within the stichocytes. The absorptive function of the bacillary band calls for an exploration of its possible role in the uptake...

  3. Infrared Absorption Band Assignment in Benzanilide and Some of its p

    African Journals Online (AJOL)

    MBI

    2014-07-10

    nitrobenzanilide only. However, no absorption band(s) that can be readily attributed to Amide VI mode was observed for all the benzanilides. Keywords: Benzanilide, IR Absorption Band. INTRODUCTION. The infrared absorption spectra ...

  4. Interpretation of Absorption Bands in Airborne Hyperspectral Radiance Data

    Directory of Open Access Journals (Sweden)

    W. David Miller

    2009-04-01

    Full Text Available It is demonstrated that hyperspectral imagery can be used, without atmospheric correction, to determine the presence of accessory phytoplankton pigments in coastal waters using derivative techniques. However, care must be taken not to confuse other absorptions for those caused by the presence of pigments. Atmospheric correction, usually the first step to making products from hyperspectral data, may not completely remove Fraunhofer lines and atmospheric absorption bands and these absorptions may interfere with identification of phytoplankton accessory pigments. Furthermore, the ability to resolve absorption bands depends on the spectral resolution of the spectrometer, which for a fixed spectral range also determines the number of observed bands. Based on this information, a study was undertaken to determine under what circumstances a hyperspectral sensor may determine the presence of pigments. As part of the study a hyperspectral imager was used to take high spectral resolution data over two different water masses. In order to avoid the problems associated with atmospheric correction this data was analyzed as radiance data without atmospheric correction. Here, the purpose was to identify spectral regions that might be diagnostic for photosynthetic pigments. Two well proven techniques were used to aid in absorption band recognition, the continuum removal of the spectra and the fourth derivative. The findings in this study suggest that interpretation of absorption bands in remote sensing data, whether atmospherically corrected or not, have to be carefully reviewed when they are interpreted in terms of photosynthetic pigments.

  5. Theory of two-photon absorption by exciton states in cubic semiconductors with degenerate valence bands

    International Nuclear Information System (INIS)

    Nguyen Ai Viet; Nguyen Toan Thang.

    1987-06-01

    The coefficient of the absorption of two polarized photons is calculated for direct band gap semiconductors with degenerate valence bands. Wannier-Mott exciton states are included in both the intermediate and final states. Numerical calculations are performed for ZnSe and are compared with Sondergeld's experimental and theoretical results. (author). 11 refs, 2 tabs

  6. Uncertainty analysis for the coefficient of band-to-band absorption of crystalline silicon

    Directory of Open Access Journals (Sweden)

    Carsten Schinke

    2015-06-01

    Full Text Available We analyze the uncertainty of the coefficient of band-to-band absorption of crystalline silicon. For this purpose, we determine the absorption coefficient at room temperature (295 K in the wavelength range from 250 to 1450 nm using four different measurement methods. The data presented in this work derive from spectroscopic ellipsometry, measurements of reflectance and transmittance, spectrally resolved luminescence measurements and spectral responsivity measurements. A systematic measurement uncertainty analysis based on the Guide to the expression of uncertainty in measurement (GUM as well as an extensive characterization of the measurement setups are carried out for all methods. We determine relative uncertainties of the absorption coefficient of 0.4% at 250 nm, 11% at 600 nm, 1.4% at 1000 nm, 12% at 1200 nm and 180% at 1450 nm. The data are consolidated by intercomparison of results obtained at different institutions and using different measurement approaches.

  7. Laboratory Measurements of the 940, 1130, and 1370 nm Water Vapor Absorption Band Profiles

    Science.gov (United States)

    Giver, Lawrence P.; Gore, Warren J.; Pilewskie, P.; Freedman, R. S.; Chackerian, C., Jr.; Varanasi, P.

    2001-01-01

    We have used the solar spectral flux radiometer (SSFR) flight instrument with the Ames 25 meter base-path White cell to obtain about 20 moderate resolution (8 nm) pure water vapor spectra from 650 to 1650 nm, with absorbing paths from 806 to 1506 meters and pressures up to 14 torr. We also obtained a set at 806 meters with several different air-broadening pressures. Model simulations were made for the 940, 1130, and 1370 nm absorption bands for some of these laboratory conditions using the Rothman, et al HITRAN-2000 linelist. This new compilation of HITRAN includes new intensity measurements for the 940 nm region. We compared simulations for our spectra of this band using HITRAN-2000 with simulations using the prior HITRAN-1996. The simulations of the 1130 nm band show about 10% less absorption than we measured. There is some evidence that the total intensity of this band is about 38% stronger than the sum of the HITRAN line intensities in this region. In our laboratory conditions the absorption depends approximately on the square root of the intensity. Thus, our measurements agree that the band is stronger than tabulated in HITRAN, but by about 20%, substantially less than the published value. Significant differences have been shown between Doppler-limited resolution spectra of the 1370 nm band obtained at the Pacific Northwest National Laboratory and HITRAN simulations. Additional new intensity measurements in this region are continuing to be made. We expect the simulations of our SSFR lab data of this band will show the relative importance of improving the HITRAN line intensities of this band for atmospheric measurements.

  8. Comparative study of five varieties of spodumene through optical absorption

    International Nuclear Information System (INIS)

    Fujii, A.T.; Isotani, S.

    1983-11-01

    A comparative study of five varieties of spodumene crystals from Brazil through optical absorption spectroscopy, classified according to the colours lylac, colourless I, colourless II, yellow and green is reported. This series shows a consistent increase of the [Fe]/[Mn] ratio. The principal bands in the yellow sample are at 7,000 and 9,000 cm -1 , and in the green sample besides these bands a band at 16,000 cm -1 is observed. In lylac, colourless I and colourless II samples, the principal bands are at 18,000 cm -1 and when irradiated two new bands appears at 15,700 cm -1 (E perpendicular to c) and 11,000 cm -1 (K perpendicular to c). It is suggested that in green and yellow samples the bands are due to Fe 2+ (at 7,000 cm -1 and 9,000 cm -1 ) and due to Fe 2+ - Fe 3+ charge transfer (at 16,000 cm -1 ). In lylac and colourless I samples the model for Mn 3+ at two different sites is applied. The colourless II corresponds to the case in which Mn 3+ is at one site alone, being prohibited from occupying the second site due to higher Fe concentration. (Author) [pt

  9. Studies on the red absorption band of chlorophyll a in vivo

    NARCIS (Netherlands)

    Thomas, J.B.; Kleinen Hammans, J.W.; Arnolds, W.J.

    1965-01-01

    It was studied whether certain earlier observed weak shoulders on the red absorption band of chlorophyll a in vivo might represent anomalies due to overlap of absorption bands. The results are suggested of the fact that no such anomalies occur. It is therefore concluded that the present study

  10. Experimental study of absorption band controllable planar metamaterial absorber using asymmetrical snowflake-shaped configuration

    Science.gov (United States)

    Huang, Yongjun; Tian, Yiran; Wen, Guangjun; Zhu, Weiren

    2013-05-01

    In this paper, we systematically discuss a novel planar metamaterial absorber (PMA) based on asymmetrical snowflake-shaped resonators, which can exhibit two distinctly different absorption states, single- and dual-band absorptions, by controlling the branch lengths of the proposed resonators. Numerical simulations and experimental measurements are employed to investigate these two kinds of absorption characteristic in an X-band rectangular waveguide. Both results indicate that such a PMA exhibits a wide range of controllable operating frequencies for the single- and dual-band conditions. The proposed PMA is simple and easy to make, and it has wide applications in the fields of stealth technologies, thermal detectors, and imaging.

  11. Optical Salisbury screen with design-tunable resonant absorption bands

    Science.gov (United States)

    Nath, Janardan; Smith, Evan; Maukonen, Douglas; Peale, Robert E.

    2014-05-01

    A thin-film selective absorber at visible and near infra-red wavelengths is demonstrated. The structure consists of an optically thick layer of gold, a SiO2 dielectric spacer and a partially transparent gold film on top. The optical cavity so formed traps and absorbs light at a resonance wavelength determined by the film thicknesses. Observed fundamental-resonance absorption strengths are in the range 93%-97%. The absorption red-shifts and broadens as the thickness of the top gold layer is decreased with little change in absorption strength. Thus, strong absorption with design-tunable wavelength and width is achieved easily by unstructured blanket depositions. Observed angle-dependent spectra agree well with the recent three-layer analytical model of Shu et al. [Opt. Express 21, 25307 (2013)], if effective medium approximation is used to calculate the permittivity of the top gold film when it becomes discontinuous at the lowest thicknesses.

  12. Molecular design for improved photovoltaic efficiency: band gap and absorption coefficient engineering

    KAUST Repository

    Mondal, Rajib

    2009-01-01

    Removing the adjacent thiophene groups around the acceptor core in low band gap polymers significantly enhances solar cell efficiency through increasing the optical absorption and raising the ionization potential of the polymer. © 2009 The Royal Society of Chemistry.

  13. Enhancement of broadband optical absorption in photovoltaic devices by band-edge effect of photonic crystals.

    Science.gov (United States)

    Tanaka, Yoshinori; Kawamoto, Yosuke; Fujita, Masayuki; Noda, Susumu

    2013-08-26

    We numerically investigate broadband optical absorption enhancement in thin, 400-nm thick microcrystalline silicon (µc-Si) photovoltaic devices by photonic crystals (PCs). We realize absorption enhancement by coupling the light from the free space to the large area resonant modes at the photonic band-edge induced by the photonic crystals. We show that multiple photonic band-edge modes can be produced by higher order modes in the vertical direction of the Si photovoltaic layer, which can enhance the absorption on multiple wavelengths. Moreover, we reveal that the photonic superlattice structure can produce more photonic band-edge modes that lead to further optical absorption. The absorption average in wavelengths of 500-1000 nm weighted to the solar spectrum (AM 1.5) increases almost twice: from 33% without photonic crystal to 58% with a 4 × 4 period superlattice photonic crystal; our result outperforms the Lambertian textured structure.

  14. High resolution absorption cross-sections and band oscillator strengths of the Schumann-Runge absorption bands of isotopic oxygen, (O-18)2, at 79 K

    Science.gov (United States)

    Yoshino, K.; Freeman, D. E.; Esmond, J. R.; Friedman, R. S.; Parkinson, W. H.

    1988-01-01

    Cross-sections of (O-18)2 at 79 K have been obtained from photoabsorption measurements at various pressures throughout the wavelength region 177.8-197.8 nm with a 6.65 m photoelectric scanning spectrometer equipped with a 2400 lines/mm grating and having an instrumental width (FWHM) of 0.0013 nm. The measured absorption cross-sections of the Schumann-Runge bands (14,0) through (2,0) are, with the exception of the (12,0) band, independent of the instrumental width. The measured cross-sections are presented graphically here and are available at wavenumber intervals of about 0.1/cm as numerical compilations stored on magnetic tape. Band oscillator strengths of those bands have been determined by direct numerical integration of the measured absolute cross-sections and are in excellent agreement with these theoretically calculated values.

  15. C3H2 : A wide-band-gap semiconductor with strong optical absorption

    Science.gov (United States)

    Lu, Hong-Yan; Cuamba, Armindo S.; Geng, Lei; Hao, Lei; Qi, Yu-Min; Ting, C. S.

    2017-10-01

    Using first-principles calculations, we predict a new type of partially hydrogenated graphene system, C3H2 , which turns out to be a semiconductor with a band gap of 3.56 eV. The bands are rather flat at the band edges and thus lead to a large density of states, which further results in strong optical absorption between the valence band and the conduction band. Particularly, it shows strong optical absorption at about 4.5 eV for the light polarized along the lines connecting the nearest unhydrogenated carbon atoms. Thus, the predicted C3H2 system may have potential applications for a polarizer as well as other high-efficiency optical devices in the near ultraviolet region.

  16. Robust indirect band gap and anisotropy of optical absorption in B-doped phosphorene.

    Science.gov (United States)

    Wu, Zhi-Feng; Gao, Peng-Fei; Guo, Lei; Kang, Jun; Fang, Dang-Qi; Zhang, Yang; Xia, Ming-Gang; Zhang, Sheng-Li; Wen, Yu-Hua

    2017-12-06

    A traditional doping technique plays an important role in the band structure engineering of two-dimensional nanostructures. Since electron interaction is changed by doping, the optical and electrochemical properties could also be significantly tuned. In this study, density functional theory calculations have been employed to explore the structural stability, and electronic and optical properties of B-doped phosphorene. The results show that all B-doped phosphorenes are stable with a relatively low binding energy. Of particular interest is that these B-doped systems exhibit an indirect band gap, which is distinct from the direct one of pure phosphorene. Despite the different concentrations and configurations of B dopants, such indirect band gaps are robust. The screened hybrid density functional HSE06 predicts that the band gap of B-doped phosphorene is slightly smaller than that of pure phosphorene. Spatial charge distributions at the valence band maximum (VBM) and the conduction band minimum (CBM) are analyzed to understand the features of an indirect band gap. By comparison with pure phosphorene, B-doped phosphorenes exhibit strong anisotropy and intensity of optical absorption. Moreover, B dopants could enhance the stability of Li adsorption on phosphorene with less sacrifice of the Li diffusion rate. Our results suggest that B-doping is an effective way of tuning the band gap, enhancing the intensity of optical absorption and improving the performances of Li adsorption, which could promote potential applications in novel optical devices and lithium-ion batteries.

  17. Diversity in the Visible-NIR Absorption Band Characteristics of Lunar and Asteroidal Plagioclase

    Science.gov (United States)

    Hiroi, T.; Kaiden, H.; Misawa, K.; Kojima, H.; Uemoto, K.; Ohtake, M.; Arai, T.; Sasaki, S.; Takeda, H.; Nyquist, L. E.; hide

    2012-01-01

    Studying the visible and near-infrared (VNIR) spectral properties of plagioclase has been challenging because of the difficulty in obtaining good plagioclase separates from pristine planetary materials such as meteorites and returned lunar samples. After an early study indicated that the 1.25 m band position of plagioclase spectrum might be correlated with the molar percentage of anorthite (An#) [1], there have been few studies which dealt with the band center behavior. In this study, the VNIR absorption band parameters of plagioclase samples have been derived using the modified Gaussian model (MGM) [2] following a pioneering study by [3].

  18. Set of X-Band distributed absorptive limiter GaAs MMICs

    NARCIS (Netherlands)

    Maas, A.P.M.; Janssen, J.P.B.; Vliet, F.E. van

    2007-01-01

    A set of X-band absorptive limiter GaAs MMICs has been designed and realised using both the PPH25x foundry process from UMS and the PP50-10 process from WIN semiconductors. The innovative limiter concepts have been extensively characterised by both pulsed and CW measurements. Both passive and active

  19. Effect of Atmospheric Absorption Bands on the Optimal Design of Multijunction Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, William E.; Friedman, Daniel J.; Geisz, John F.

    2017-06-26

    Designing terrestrial multijunction (MJ) cells with 5+ junctions is challenging, in part because the presence of atmospheric absorption bands creates a design space with numerous local maxima. Here we introduce a new taxonomical structure which facilitates both numerical convergence and the visualization of the resulting designs.

  20. Wide-band underwater acoustic absorption based on locally resonant unit and interpenetrating network structure

    International Nuclear Information System (INIS)

    Heng, Jiang; Mi-Lin, Zhang; Yu-Ren, Wang; Yan-Ping, Hu; Ding, Lan; Qun-Li, Wu; Huan-Tong, Lu

    2010-01-01

    The interpenetrating network structure provides an interesting avenue to novel materials. Locally resonant phononic crystal (LRPC) exhibits excellent sound attenuation performance based on the periodical arrangement of sound wave scatters. Combining the LRPC concept and interpenetrating network glassy structure, this paper has developed a new material which can achieve a wide band underwater strong acoustic absorption. Underwater absorption coefficients of different samples were measured by the pulse tube. Measurement results show that the new material possesses excellent underwater acoustic effects in a wide frequency range. Moreover, in order to investigate impacts of locally resonant units, some defects are introduced into the sample. The experimental result and the theoretical calculation both show that locally resonant units being connected to a network structure play an important role in achieving a wide band strong acoustic absorption. (condensed matter: structure, thermal and mechanical properties)

  1. High resolution absorption cross-sections and band oscillator strengths of the Schumann-Runge absorption bands of isotopic oxygen, (0-16)(0-18), at 79 K

    Science.gov (United States)

    Yoshino, K.; Freeman, D. E.; Esmond, J. R.; Friedman, R. S.; Parkinson, W. H.

    1989-01-01

    Cross-sections of (0-16)(0-18) at 79 K have been obtained from photoabsorption measurements on mixtures of (0-16)2, (0-18)2, and (0-16)(0-18) at various pressures throughout the wavelength region 180.5-195.3 nm with a 6.65 m photoelectric scanning spectrometer equipped with a 2400 lines/mm grating and having an instrumental width (FWHM) of 0.0013 nm. The measured absorption cross-sections of the (0-16)(0-18) Schumann-Runge bands (11.0)-(3.0) are independent of the instrumental width. The measured cross-sections are presented graphically.

  2. Energy band offset extraction - a comparative study

    NARCIS (Netherlands)

    van der Steen, J.P.J.; Hueting, Raymond Josephus Engelbart; Schmitz, Jurriaan

    2008-01-01

    Structural quantum confinement in thin silicon double-gate MOSFETs has been quantified using the temperature dependence of the subthreshold current. The results were compared with the shifts in threshold voltage. Data was obtained from simulations after initial verification with experimental data.

  3. Controllable Absorption and Dispersion Properties of an RF-driven Five-Level Atom in a Double-Band Photonic-Band-Gap Material

    International Nuclear Information System (INIS)

    Ding Chunling; Li Jiahua; Yang Xiaoxue

    2011-01-01

    The probe absorption-dispersion spectra of a radio-frequency (RF)-driven five-level atom embedded in a photonic crystal are investigated by considering the isotropic double-band photonic-band-gap (PBG) reservoir. In the model used, the two transitions are, respectively, coupled by the upper and lower bands in such a PBG material, thus leading to some curious phenomena. Numerical simulations are performed for the optical spectra. It is found that when one transition frequency is inside the band gap and the other is outside the gap, there emerge three peaks in the absorption spectra. However, for the case that two transition frequencies lie inside or outside the band gap, the spectra display four absorption profiles. Especially, there appear two sharp peaks in the spectra when both transition frequencies exist inside the band gap. The influences of the intensity and frequency of the RF-driven field on the absorptive and dispersive response are analyzed under different band-edge positions. It is found that a transparency window appears in the absorption spectra and is accompanied by a very steep variation of the dispersion profile by adjusting system parameters. These results show that the absorption-dispersion properties of the system depend strongly on the RF-induced quantum interference and the density of states (DOS) of the PBG reservoir. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  4. Determination of the Rb atomic number density in dense rubidium vapors by absorption measurements of Rb2 triplet bands

    International Nuclear Information System (INIS)

    Horvatic, Vlasta; Veza, Damir; Niemax, Kay; Vadla, Cedomil

    2008-01-01

    A simple and accurate way of determining atom number densities in dense rubidium vapors is presented. The method relies on the experimental finding that the reduced absorption coefficients of the Rb triplet satellite bands between 740 nm and 750 nm and the triplet diffuse band between 600 nm and 610 nm are not temperature dependent in the range between 600 K and 800 K. Therefore, the absolute values of the reduced absorption coefficients of these molecular bands can provide accurate information about atomic number density of the vapor. The rubidium absorption spectrum was measured by spatially resolved white-light absorption in overheated rubidium vapor generated in a heat pipe oven. The absolute values for the reduced absorption coefficients of the triplet bands were determined at lower vapor densities, by using an accurate expression for the reduced absorption coefficient in the quasistatic wing of the Rb D1 line, and measured triplet satellite bands to the resonance wing optical depth ratio. These triplet satellite band data were used to calibrate in absolute scale the reduced absorption coefficients of the triplet diffuse band at higher temperatures. The obtained values for the reduced absorption coefficient of these Rb molecular features can be used for accurate determination of rubidium atomic number densities in the range from about 5 x 10 16 cm -3 to 1 x 10 18 cm -3

  5. PHASE ANGLE EFFECTS ON 3 μm ABSORPTION BAND ON CERES: IMPLICATIONS FOR DAWN MISSION

    International Nuclear Information System (INIS)

    Takir, D.; Reddy, V.; Sanchez, J. A.; Corre, L. Le; Hardersen, P. S.; Nathues, A.

    2015-01-01

    Phase angle-induced spectral effects are important to characterize since they affect spectral band parameters such as band depth and band center, and therefore skew mineralogical interpretations of planetary bodies via reflectance spectroscopy. Dwarf planet (1) Ceres is the next target of NASA’s Dawn mission, which is expected to arrive in 2015 March. The visible and near-infrared mapping spectrometer (VIR) on board Dawn has the spatial and spectral range to characterize the surface between 0.25–5.0 μm. Ceres has an absorption feature at 3.0 μm due to hydroxyl- and/or water-bearing minerals. We analyzed phase angle-induced spectral effects on the 3 μm absorption band on Ceres using spectra measured with the long-wavelength cross-dispersed (LXD: 1.9–4.2 μm) mode of the SpeX spectrograph/imager at the NASA Infrared Telescope Facility. Ceres LXD spectra were measured at different phase angles ranging from 0.°7 to 22°. We found that the band center slightly increases from 3.06 μm at lower phase angles (0.°7 and 6°) to 3.07 μm at higher phase angles (11° and 22°), the band depth decreases by ∼20% from lower phase angles to higher phase angles, and the band area decreases by ∼25% from lower phase angles to higher phase angles. Our results will have implications for constraining the abundance of OH on the surface of Ceres from VIR spectral data, which will be acquired by Dawn starting spring 2015

  6. Attempt at interpreting some optical absorption bands in X-ray irradiated fluorine

    International Nuclear Information System (INIS)

    Allain, Yves

    1959-01-01

    According to the results of one of our experiments, the 575 mμ absorption band of fluorine irradiated with X-Rays seams due to F - ion vacancies. Our goal has been to find a color centers model in fluorine colored in various conditions. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 248, p. 2318-2320, sitting of Aril 20, 1959 [fr

  7. Microwave absorption behaviour of MWCNT based nanocomposites in X-band region

    Directory of Open Access Journals (Sweden)

    C. K. Das

    2013-03-01

    Full Text Available Multiwall carbon nanotube (MWCNT based nanocomposites were prepared by a two-step process. Firstly, titanium dioxide (TiO2 coated MWCNT was prepared via sol-gel technique. In the second step, the acid modified MWCNTs were dispersed in the thermoplastic polyurethane matrix by solution blending process. Characterizations of the nanocomposites were done by X-ray diffraction analysis, X-ray photoelectron spectroscopy, Scanning Electron Microscopy, Transmission Electron Microscopy and Energy-dispersive X-ray spectroscopy. Microwave absorption studies of the nanocomposites were carried out in X-band region. The microwave absorption result was discussed with the help of complex permittivity and permeability of the prepared radar absorbing material (RAM. The result showed superior microwave absorption property of the composite containing both TiO2 coated MWCNT and magnetite (Fe3O4. This result is due to the effective absorption of both electrical and magnetic components of the microwave. RAM-MW, RAM-Ti, RAM-Ti@MW and RAMTi@ MW/Fe and showed the maximum reflection loss of –16.03 dB at 10.99 GHz, –8.4 dB at 12.4 GHz, –36.44 dB at 12.05 GHz and –42.53 dB at 10.98 GHz respectively. Incorporation of MWCNT enhanced the thermal stability of the composite which has been confirmed by thermogravimetric analysis.

  8. Study of sub band gap absorption of Sn doped CdSe thin films

    International Nuclear Information System (INIS)

    Kaur, Jagdish; Rani, Mamta; Tripathi, S. K.

    2014-01-01

    The nanocrystalline thin films of Sn doped CdSe at different dopants concentration are prepared by thermal evaporation technique on glass substrate at room temperature. The effect of Sn doping on the optical properties of CdSe has been studied. A decrease in band gap value is observed with increase in Sn concentration. Constant photocurrent method (CPM) is used to study the absorption coefficient in the sub band gap region. Urbach energy has been obtained from CPM spectra which are found to increase with amount of Sn dopants. The refractive index data calculated from transmittance is used for the identification of oscillator strength and oscillator energy using single oscillator model which is found to be 7.7 and 2.12 eV, 6.7 and 2.5 eV for CdSe:Sn 1% and CdSe:Sn 5% respectively

  9. Study of sub band gap absorption of Sn doped CdSe thin films

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Jagdish; Rani, Mamta [Department of Physics, Panjab University, Chandigarh- 160014 (India); Tripathi, S. K., E-mail: surya@pu.ac.in [Centre of Advanced Study in Physics, Panjab University, Chandigarh- 160014 (India)

    2014-04-24

    The nanocrystalline thin films of Sn doped CdSe at different dopants concentration are prepared by thermal evaporation technique on glass substrate at room temperature. The effect of Sn doping on the optical properties of CdSe has been studied. A decrease in band gap value is observed with increase in Sn concentration. Constant photocurrent method (CPM) is used to study the absorption coefficient in the sub band gap region. Urbach energy has been obtained from CPM spectra which are found to increase with amount of Sn dopants. The refractive index data calculated from transmittance is used for the identification of oscillator strength and oscillator energy using single oscillator model which is found to be 7.7 and 2.12 eV, 6.7 and 2.5 eV for CdSe:Sn 1% and CdSe:Sn 5% respectively.

  10. Electronic absorption bands of HoCl3 and SmCl3 complexes in alcohols

    International Nuclear Information System (INIS)

    Ramesh Babu, V.; Buddhudu, S.; Rangarajan, V.N.

    1987-01-01

    The normal absorption and second derivative spectra of ten alcoholic complexes of HoCl 3 and SmCl 3 were recorded. From the observed bands, energies and intensity values were measured. To fit in these measured values with the theoretical values, a set of spectroscopic parameters namely, Judd-Ofelt (T 2 , T 4 , T 6 ), intensity (Ω 2 , Ω 4 , Ω 6 ) had been computed. A good fit of intensities was obtained between the experimental and theoretical data. The environmental influences on the intensities of the hypersensitive transitions of Sm(III) and Ho(III) ions were found to be noteworthy. (author). 7 tables, 20 refs

  11. Water vapor measurements in the 0.94 micron absorption band - Calibration, measurements and data applications

    Science.gov (United States)

    Reagan, J. A.; Thome, K.; Herman, B.; Gall, R.

    1987-01-01

    This paper describes methods and presents results for sensing the columnar content of atmospheric water vapor via differential solar transmission measurements in and adjacent to the 0.94-micron water-vapor absorption band. Calibration and measurement techniques are presented for obtaining the water vapor transmission from the radiometer measurements. Models are also presented for retrieving the columnar water vapor amount from the estimated transmission. Example retrievals are presented for radiometer measurements made during the 1986 Arizona Monsoon Season to track temporal variations in columnar water vapor amount.

  12. Band gap opening and optical absorption enhancement in graphene using ZnO nanocluster

    Science.gov (United States)

    Monshi, M. M.; Aghaei, S. M.; Calizo, I.

    2018-05-01

    Electronic, optical and transport properties of the graphene/ZnO heterostructure have been explored using first-principles density functional theory. The results show that Zn12O12 can open a band gap of 14.5 meV in graphene, increase its optical absorption by 1.67 times covering the visible spectrum which extends to the infra-red (IR) range, and exhibits a slight non-linear I-V characteristic depending on the applied bias. These findings envisage that a graphene/Zn12O12 heterostructure can be appropriate for energy harvesting, photodetection, and photochemical devices.

  13. Comparative study of vapour compression, thermoelectric and absorption refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, P.K.; Martin, A. [Auckland Univ., Dept. of Mechanical Engineering, Auckland (New Zealand)

    2000-07-01

    This paper investigates the performance characteristics of the three domestic refrigerators, namely the vapour compression (VC), the thermoelectric (TE) and the absorption refrigeration (AR). AR and TE refrigerators are the result of research and development in refrigeration systems in the quest to find a cooling system which does not use any refrigerant that damages the ozone layer. Three refrigerators of similar capacity (about 50l) were compared for their usage in the hotel industry in view of their energy efficiency, noise produced and cost (owning as well as running). It was found that the VC refrigerator consumed the least energy, was least costly but was the noisiest. The absorption refrigerator was the quietest of the three but was the least energy efficient and most expensive. The thermoelectric refrigerator was the costliest, nearly as noisy as the VC but was a little less energy efficient than the absorption refrigerator. (Author)

  14. Constructing Repairable Meta-Structures of Ultra-Broad-Band Electromagnetic Absorption from Three-Dimensional Printed Patterned Shells.

    Science.gov (United States)

    Song, Wei-Li; Zhou, Zhili; Wang, Li-Chen; Cheng, Xiao-Dong; Chen, Mingji; He, Rujie; Chen, Haosen; Yang, Yazheng; Fang, Daining

    2017-12-13

    Ultra-broad-band electromagnetic absorption materials and structures are increasingly attractive for their critical role in competing with the advanced broad-band electromagnetic detection systems. Mechanically soft and weak wax-based materials composites are known to be insufficient to serve in practical electromagnetic absorption applications. To break through such barriers, here we developed an innovative strategy to enable the wax-based composites to be robust and repairable meta-structures by employing a three-dimensional (3D) printed polymeric patterned shell. Because of the integrated merits from both the dielectric loss wax-based composites and mechanically robust 3D printed shells, the as-fabricated meta-structures enable bear mechanical collision and compression, coupled with ultra-broad-band absorption (7-40 and 75-110 GHz, reflection loss  smaller than -10 dB) approaching state-of-the-art electromagnetic absorption materials. With the assistance of experiment and simulation methods, the design advantages and mechanism of employing such 3D printed shells for substantially promoting the electromagnetic absorption performance have been demonstrated. Therefore, such universal strategy that could be widely extended to other categories of wax-based composites highlights a smart stage on which high-performance practical multifunction meta-structures with ultra-broad-band electromagnetic absorption could be envisaged.

  15. Depolarisation of light scattered by disperse systems of low-dimensional potassium polytitanate nanoparticles in the fundamental absorption band

    Energy Technology Data Exchange (ETDEWEB)

    Zimnyakov, D A; Yuvchenko, S A [Yu A Gagarin Saratov State Technical University, Saratov (Russian Federation); Pravdin, A B; Kochubey, V I [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation); Gorokhovsky, A V; Tretyachenko, E V; Kunitsky, A I

    2014-07-31

    The results of experimental studies of depolarising properties of disperse systems on the basis of potassium polytitanate nanoplatelets and nanoribbons in the visible and near-UV spectral regions are presented. It is shown that in the fundamental absorption band of the nanoparticle material the increase in the depolarisation factor takes place for the radiation scattered perpendicularly to the direction of the probing beam. For nanoribbons a pronounced peak of depolarisation is observed, which is caused by the essential anisotropy of the particles shape and the peculiarities of the behaviour of the material dielectric function. The empirical data are compared with the theoretical results for 'nanodiscs' and 'nanoneedles' with the model dielectric function, corresponding to that obtained from optical constants of the titanium dioxide dielectric function. (laser biophotonics)

  16. Photodoping and enhanced visible light absorption in single-walled carbon nanotubes functionalized with a wide band gap oligomer.

    Science.gov (United States)

    Bunes, Benjamin R; Xu, Miao; Zhang, Yaqiong; Gross, Dustin E; Saha, Avishek; Jacobs, Daniel L; Yang, Xiaomei; Moore, Jeffrey S; Zang, Ling

    2015-01-07

    Carbon nanotubes feature excellent electronic properties but narrow absorption bands limit their utility in certain optoelectronic devices, including photovoltaic cells. Here, the addition of a wide-bandgap gap oligomer enhances light absorption in the visible spectrum. Furthermore, the oligomer interacts with the carbon nanotube through a peculiar charge transfer, which provides insight into Type II heterojunctions. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. The Role of the Absorption in the Stop Band Tuning of Opals and Inverse Opals Through Coating of Semiconductor Materials

    Science.gov (United States)

    Manzanares-Martinez, Jesus

    2005-03-01

    In this work we report on the modeling of the optical properties of semiconductor in-filled opals and inverse opals for the visible and near infrared spectral region. The crucial influence of the absorption is theoretically investigated by using the three dimensional Transfer Matrix Method (TMM). Fine-tuning of the stop band positioning is achieved with increasing semiconductor infiltration. The red shift of the stop band can be explained by Bragg's law. However, the optical properties depend strongly on the value of the absorption that is directly related to the imaginary part of the Dielectric Constant (DC). We use a realistic model of the DC for a specific semiconductor (InSb) that takes into account the phononic contributions, intrinsic electron and hole densities. By positioning the stop band in the region of the smaller value of the imaginary part of the DC we optimize the value of the lattice constant in order to optimize tuning of the stop band with fewer losses. We also study the influence of absorption in the Fabry-Perot oscillations and in the higher energy stop bands. This work is motivated by new experimental results that show that absorption in 3D structures can be the limiting factor to obtain a useful structure for tuning.

  18. Design of an ultra-thin absorption layer with magnetic materials based on genetic algorithm at the S band

    Science.gov (United States)

    Wang, Fang; Yang, Xiaoning; Liu, Xiaoning; Niu, Tiaoming; Wang, Jing; Mei, Zhonglei; Jian, Yabin

    2018-04-01

    In this work, we design an ultra-thin absorption coating at the S band, and the total thickness is less than 2 mm. For incident angle less than 30 degree and the whole S band, the reflection is less than -5 dB. The coating is constructed with 4/3 layers of magnetic material with different thicknesses, which are optimized by using genetic algorithm. Analytic and simulation results confirm the correctness of the design.

  19. Calcium absorption from fortified ice cream formulations compared with calcium absorption from milk.

    Science.gov (United States)

    van der Hee, Regine M; Miret, Silvia; Slettenaar, Marieke; Duchateau, Guus S M J E; Rietveld, Anton G; Wilkinson, Joy E; Quail, Patricia J; Berry, Mark J; Dainty, Jack R; Teucher, Birgit; Fairweather-Tait, Susan J

    2009-05-01

    Optimal bone mass in early adulthood is achieved through appropriate diet and lifestyle, thereby protecting against osteoporosis and risk of bone fracture in later life. Calcium and vitamin D are essential to build adequate bones, but calcium intakes of many population groups do not meet dietary reference values. In addition, changes in dietary patterns are exacerbating the problem, thereby emphasizing the important role of calcium-rich food products. We have designed a calcium-fortified ice cream formulation that is lower in fat than regular ice cream and could provide a useful source of additional dietary calcium. Calcium absorption from two different ice cream formulations was determined in young adults and compared with milk. Sixteen healthy volunteers (25 to 45 years of age), recruited from the general public of The Netherlands, participated in a randomized, reference-controlled, double-blind cross-over study in which two test products and milk were consumed with a light standard breakfast on three separate occasions: a standard portion of ice cream (60 g) fortified with milk minerals and containing a low level (3%) of butter fat, ice cream (60 g) fortified with milk minerals and containing a typical level (9%) of coconut oil, and reduced-fat milk (1.7% milk fat) (200 mL). Calcium absorption was measured by the dual-label stable isotope technique. Effects on calcium absorption were evaluated by analysis of variance. Fractional absorption of calcium from the 3% butterfat ice cream, 9% coconut oil ice cream, and milk was 26%+/-8%, 28%+/-5%, and 31%+/-9%, respectively, and did not differ significantly (P=0.159). Results indicate that calcium bioavailability in the two calcium-fortified ice cream formulations used in this study is as high as milk, indicating that ice cream may be a good vehicle for delivery of calcium.

  20. The impact of different multi-walled carbon nanotubes on the X-band microwave absorption of their epoxy nanocomposites.

    Science.gov (United States)

    Che, Bien Dong; Nguyen, Bao Quoc; Nguyen, Le-Thu T; Nguyen, Ha Tran; Nguyen, Viet Quoc; Van Le, Thang; Nguyen, Nieu Huu

    2015-01-01

    Carbon nanotube (CNT) characteristics, besides the processing conditions, can change significantly the microwave absorption behavior of CNT/polymer composites. In this study, we investigated the influence of three commercial multi-walled CNT materials with various diameters and length-to-diameter aspect ratios on the X-band microwave absorption of epoxy nanocomposites with CNT contents from 0.125 to 2 wt%, prepared by two dispersion methods, i.e. in solution with surfactant-aiding and via ball-milling. The laser diffraction particle size and TEM analysis showed that both methods produced good dispersions at the microscopic level of CNTs. Both a high aspect ratio resulting in nanotube alignment trend and good infiltration of the matrix in the individual nanotubes, which was indicated by high Brookfield viscosities at low CNT contents of CNT/epoxy dispersions, are important factors to achieve composites with high microwave absorption characteristics. The multi-walled carbon nanotube (MWCNT) with the largest aspect ratio resulted in composites with the best X-band microwave absorption performance, which is considerably better than that of reported pristine CNT/polymer composites with similar or lower thicknesses and CNT loadings below 4 wt%. A high aspect ratio of CNTs resulting in microscopic alignment trend of nanotubes as well as a good level of micro-scale CNT dispersion resulting from good CNT-matrix interactions are crucial to obtain effective microwave absorption performance. This study demonstrated that effective radar absorbing MWCNT/epoxy nanocomposites having small matching thicknesses of 2-3 mm and very low filler contents of 0.25-0.5 wt%, with microwave energy absorption in the X-band region above 90% and maximum absorption peak values above 97%, could be obtained via simple processing methods, which is promising for mass production in industrial applications. Graphical AbstractComparison of the X-band microwave reflection loss of epoxy composites of

  1. Extraordinary terahertz absorption bands observed in micro/nanostructured Au/polystyrene sphere arrays

    Science.gov (United States)

    2012-01-01

    Terahertz (THz) time-domain spectroscopy is carried out for micro/nanostructured periodic Au/dielectric sphere arrays on Si substrate. We find that the metal-insulator transition can be achieved in THz bandwidth via varying sample parameters such as the thickness of the Au shell and the diameter of the Au/dielectric sphere. The Au/polystyrene sphere arrays do not show metallic THz response when the Au shell thickness is larger than 10 nm and the sphere diameter is smaller than 500 nm. This effect is in sharp contrast to the observations in flat Au films on Si substrate. Interestingly, the Au/polystyrene sphere arrays with a 5-nm-thick Au shell show extraordinary THz absorption bands or metallic optical conductance when the diameter of the sphere is larger than 200 nm. This effect is related to the quantum confinement effect in which the electrons in the structure are trapped in the sphere potential well of the gold shell. PMID:23190688

  2. Multilayer Cloud Detection with the MODIS Near-Infrared Water Vapor Absorption Band

    Science.gov (United States)

    Wind, Galina; Platnick, Steven; King, Michael D.; Hubanks, Paul A,; Pavolonis, Michael J.; Heidinger, Andrew K.; Yang, Ping; Baum, Bryan A.

    2009-01-01

    Data Collection 5 processing for the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the NASA Earth Observing System EOS Terra and Aqua spacecraft includes an algorithm for detecting multilayered clouds in daytime. The main objective of this algorithm is to detect multilayered cloud scenes, specifically optically thin ice cloud overlying a lower-level water cloud, that presents difficulties for retrieving cloud effective radius using single layer plane-parallel cloud models. The algorithm uses the MODIS 0.94 micron water vapor band along with CO2 bands to obtain two above-cloud precipitable water retrievals, the difference of which, in conjunction with additional tests, provides a map of where multilayered clouds might potentially exist. The presence of a multilayered cloud results in a large difference in retrievals of above-cloud properties between the CO2 and the 0.94 micron methods. In this paper the MODIS multilayered cloud algorithm is described, results of using the algorithm over example scenes are shown, and global statistics for multilayered clouds as observed by MODIS are discussed. A theoretical study of the algorithm behavior for simulated multilayered clouds is also given. Results are compared to two other comparable passive imager methods. A set of standard cloudy atmospheric profiles developed during the course of this investigation is also presented. The results lead to the conclusion that the MODIS multilayer cloud detection algorithm has some skill in identifying multilayered clouds with different thermodynamic phases

  3. Estimating Snow Water Equivalent with Backscattering at X and Ku Band Based on Absorption Loss

    Directory of Open Access Journals (Sweden)

    Yurong Cui

    2016-06-01

    Full Text Available Snow water equivalent (SWE is a key parameter in the Earth’s energy budget and water cycle. It has been demonstrated that SWE can be retrieved using active microwave remote sensing from space. This necessitates the development of forward models that are capable of simulating the interactions of microwaves and the snow medium. Several proposed models have described snow as a collection of sphere- or ellipsoid-shaped ice particles embedded in air, while the microstructure of snow is, in reality, more complex. Natural snow usually forms a sintered structure following mechanical and thermal metamorphism processes. In this research, the bi-continuous vector radiative transfer (bi-continuous-VRT model, which firstly constructs snow microstructure more similar to real snow and then simulates the snow backscattering signal, is used as the forward model for SWE estimation. Based on this forward model, a parameterization scheme of snow volume backscattering is proposed. A relationship between snow optical thickness and single scattering albedo at X and Ku bands is established by analyzing the database generated from the bi-continuous-VRT model. A cost function with constraints is used to solve effective albedo and optical thickness, while the absorption part of optical thickness is obtained from these two parameters. SWE is estimated after a correction for physical temperature. The estimated SWE is correlated with the measured SWE with an acceptable accuracy. Validation against two-year measurements, using the SnowScat instrument from the Nordic Snow Radar Experiment (NoSREx, shows that the estimated SWE using the presented algorithm has a root mean square error (RMSE of 16.59 mm for the winter of 2009–2010 and 19.70 mm for the winter of 2010–2011.

  4. X-ray absorption and reflection as probes of the GaN conduction bands: Theory and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, W.R.L.; Rashkeev, S.N.; Segall, B. [Case Western Reserve Univ., Cleveland, OH (United States)] [and others

    1997-04-01

    X-ray absorption measurements are a well-known probe of the unoccupied states in a material. The same information can be obtained by using glancing angle X-ray reflectivity. In spite of several existing band structure calculations of the group III nitrides and previous optical studies in UV range, a direct probe of their conduction band densities of states is of interest. The authors performed a joint experimental and theoretical investigation using both of these experimental techniques for wurtzite GaN.

  5. a High Resolution Spectroscopic Study of Absorption Line Profiles in the A-Band of Molecular Oxygen

    Science.gov (United States)

    Ritter, Kenneth James

    A study has been made of absorption line profiles in the A-band of molecular oxygen at 13120 cm('-1). High resolution spectra were obtained using a narrow linewidth tunable dye laser in conjunction with a multi-pass optical absorption cell, a photo-acoustic cell, and a variable temperature photo-acoustic cell. Line parameters were determined using a least-squares fitting routine which numerically adjusted parameters of certain standard line profile functions to obtain the best fit with the observed profiles. The standard line profiles used were the Voigt function, two Dicke-narrowed profiles, and a speed dependent Voigt profile. Clear deviations are shown between the observed and simple Voigt profiles, while the other three profiles were found to fit the observed profiles well. Line strengths, pressure broadening coefficients, and pressure induced frequency shifts were also determined from the measured profiles. Line strengths obtained from the absorption measurements are compared with expressions given by Childs and Mecke (1931), Schlapp (1932;1937), Tilford et al. (1965) and Watson (1968). The expressions of Tilford et al. (1965) and Watson (1968) are shown to be in closest agreement with the measurements. Self-broadening coefficients are compared with previous measurements made by other investigators as well as with theoretical calculations made using the semi-classical method of Smith and Giraud (1979). Pressure induced frequency shifts were determined by taking simultaneous spectra of two cells at different pressures. The pressure induced frequency shifts and broadening coefficients were measured in pure oxygen as a function of temperature ( -20(DEGREES)C to 100(DEGREES)C), as well as in air and the broadeners He, Ne, Ar, Kr, and Xe at ambient temperature. The measured gas broadening coefficients are shown to be in close agreement with values calculated using the method of Smith and Giraud (1979). It is also shown that the general behavior observed for the

  6. [Comparative study of absorption kinetics in intestines of rats on Xianlinggubao capsule prepared by different technologies].

    Science.gov (United States)

    Wu, Huichao; Du, Shouying; Lu, Yang; Chen, Wen; Ma, Yong; Li, Pengyue

    2011-04-01

    To study the characteristics of intestinal absorption of psoralen and isopsoralen of Xianlinggubao capsule, and compare the absorption of Xianlinggubao capsule prepared by different technologies. Non everted gut sac method was applied to investigate the influence of absorption sites and drug concentration on psoralen and isopsoralen absorption, which were determined by HPLC. Although the absorption rate constants of psoralen and isopsoralen in duodenum were more than that in jejunum and ileum, there was no significance difference between them. The absorption rate constants of psoralen kept at the same level when the concentrations of drug solution were at middle and low level, while the absorption rate constant at high level was absolutely lower than them (P Intestinal absorption of psoralen and isopsoralen may be affected by the dissolution. The absorption rate constants of psoralen and isopsoralen in new Xianlinggubao capsules are higher. The absorptions of active components absorption has significant difference in different preparation processes of Xianlinggubao capsule.

  7. Detection of metal stress in boreal forest species using the 0.67-micron chlorophyll absorption band

    Science.gov (United States)

    Singhroy, Vernon H.; Kruse, Fred A.

    1991-01-01

    Several recent studies have shown that a shift of the red-edge inflection near 0.70 micron in vegetation reflectance spectra is an indicator of metal stress, partially attributable to changes in chlorophyll concentration. This 'red-edge shift', however, is difficult to detect and has been reported both toward longer (red) and shorter (blue) wavelengths. Our work demonstrates that direct measurement of the depth and width of the chlorophyll absorption band at 0.67 micron using digital feature extraction and absorption band characterization procedures developed for the analysis of mineral spectra is a more consistent indicator of metal stress. Additionally, the magnitude of these parameters is generally greater than that of the red edge shift and thus should be more amenable to detection and mapping using field and aircraft spectrometers.

  8. The determination of kinetic parameters of LiF : Mg,Ti from thermal decaying curves of optical absorption bands

    CERN Document Server

    Yazici, A N

    2003-01-01

    In this paper, the thermal bleaching curves (TBCs) of specific optical absorption bands of LiF : Mg,Ti were measured as a function of temperature. The TBCs obtained were analysed to extract the kinetic parameters (the thermal activation energy (E) and the frequency factor (s)) of some TL glow peaks of LiF : Mg,Ti on the basis of the developed first-order kinetic model over a specified temperature region.

  9. Easily Dispersible NiFe2O4/RGO Composite for Microwave Absorption Properties in the X-Band

    Science.gov (United States)

    Bateer, Buhe; Zhang, Jianjao; Zhang, Hongchen; Zhang, Xiaochen; Wang, Chunyan; Qi, Haiqun

    2018-01-01

    Composites with good dispersion and excellent microwave absorption properties have important applications. Therefore, an easily dispersible NiFe2O4/reduced graphene oxide (RGO) composite has been prepared conveniently through a simple hydrothermal method. Highly crystalline, small size (about 7 nm) monodispersed NiFe2O4 nanoparticles (NPs) are evenly distributed on the surface of RGO. The microwave absorbability revealed that the NiFe2O4/RGO composite exhibits excellent microwave absorption properties in the X-band (8-12 GHz), and the minimum reflection loss of the NiFe2O4/RGO composite is -27.7 dB at 9.2 GHz. The NiFe2O4/RGO composite has good dispersibility in nonpolar solvent, which facilitates the preparation of stable commercial microwave absorbing coatings. It can be a promising candidate for lightweight microwave absorption materials in many application fields.

  10. High-resolution spectroscopy and global analysis of CF4 rovibrational bands to model its atmospheric absorption

    Science.gov (United States)

    Carlos, M.; Gruson, O.; Richard, C.; Boudon, V.; Rotger, M.; Thomas, X.; Maul, C.; Sydow, C.; Domanskaya, A.; Georges, R.; Soulard, P.; Pirali, O.; Goubet, M.; Asselin, P.; Huet, T. R.

    2017-11-01

    CF4, or tetrafluoromethane, is a chemically inert and strongly absorbing greenhouse gas, mainly of anthropogenic origin. In order to monitor and reduce its atmospheric emissions and concentration, it is thus necessary to obtain an accurate model of its infrared absorption. Such models allow opacity calculations for radiative transfer atmospheric models. In the present work, we perform a global analysis (divided into two distinct fitting schemes) of 17 rovibrational bands of CF4. This gives a reliable model of many of its lower rovibrational levels and allows the calculation of the infrared absorption in the strongly absorbing ν3 region (1283 cm-1 / 7.8 μm), including the main hot band, namely ν3 +ν2 -ν2 as well as ν3 +ν1 -ν1 ; we could also extrapolate the ν3 +ν4 -ν4 absorption. This represents almost 92% of the absorption at room temperature in this spectral region. A new accurate value of the C-F bond length is evaluated to re = 1.314860(21) Å. The present results have been used to update the HITRAN, GEISA and TFMeCaSDa (VAMDC) databases.

  11. Thermoluminescence and optical absorption comparative studies with TLD-100 and pure LiF

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1988-07-01

    Optical absorption (OA) studies were carried out with LiF: Mg, Ti (TLD-100) and pure LiF exposed to X radiation, 77.4 C.kg -1 (3 x 10 5 R) with the aim of relating the thermoluminescent (TL) peaks presented by TLD-100 to its intrinsic and irradiation defects. After a 280 0 C thermal treatment for 15 minutes, an absorption band at 225 nm is observed in the TLD-100 OA spectrum. This band is not observed in the case of pure LiF. A correlation between TL peak 5 and the absorption band at 310 nm is established for TLD-100. These results agree with other publications and are explained. (author) [pt

  12. Semi-Empirical Validation of the Cross-Band Relative Absorption Technique for the Measurement of Molecular Mixing Ratios

    Science.gov (United States)

    Pliutau, Denis; Prasad, Narasimha S

    2013-01-01

    Studies were performed to carry out semi-empirical validation of a new measurement approach we propose for molecular mixing ratios determination. The approach is based on relative measurements in bands of O2 and other molecules and as such may be best described as cross band relative absorption (CoBRA). . The current validation studies rely upon well verified and established theoretical and experimental databases, satellite data assimilations and modeling codes such as HITRAN, line-by-line radiative transfer model (LBLRTM), and the modern-era retrospective analysis for research and applications (MERRA). The approach holds promise for atmospheric mixing ratio measurements of CO2 and a variety of other molecules currently under investigation for several future satellite lidar missions. One of the advantages of the method is a significant reduction of the temperature sensitivity uncertainties which is illustrated with application to the ASCENDS mission for the measurement of CO2 mixing ratios (XCO2). Additional advantages of the method include the possibility to closely match cross-band weighting function combinations which is harder to achieve using conventional differential absorption techniques and the potential for additional corrections for water vapor and other interferences without using the data from numerical weather prediction (NWP) models.

  13. Stellar Multi-Photon Absorption Materials: Beyond the Telecommunication Wavelength Band.

    Science.gov (United States)

    Schwich, Torsten; Barlow, Adam; Cifuentes, Marie P; Szeremeta, Janusz; Samoc, Marek; Humphrey, Mark G

    2017-06-22

    Very large molecular two- and three-photon absorption cross-sections are achieved by appending ligated bis(diphosphine)ruthenium units to oligo(p-phenyleneethynylene) (OPE)-based "stars" with arms up to 7 phenyleneethynylene (PE) units in length. Extremely large three- and four-photon absorption cross-sections, through the telecommunications wavelengths range and beyond, are obtained for these complexes upon optimizing OPE length and the ruthenium-coordinated peripheral ligand. Multi-photon absorption (MPA) cross-sections are optimized with stars possessing arms 2 PE units in length. Peripheral ligand variation modifies MPA merit and, in particular, 4-nitrophenylethynyl ligand incorporation enhances maximal MPA values and "switches on" four-photon absorption (4PA) in these low molecular-weight complexes. The 4-nitrophenylethynyl-ligated 2PE-armed star possesses a maximal four-photon absorption cross-section of 1.8×10 -108  cm 8  s 3 at 1750 nm, and significant MPA activity extending beyond 2000 nm. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Absorption and emission line shapes in the O(2) atmospheric bands: Theoretical model and limb viewing simulations.

    Science.gov (United States)

    Abreu, V J; Bucholtz, A; Hays, P B; Ortland, D; Skinner, W R; Yee, J H

    1989-06-01

    A multiple scattering radiative transfer model has been developed to carry out a line by line calculation of the absorption and emission limb measurements that will be made by the High Resolution Doppler Imager to be flown on the Upper Atmosphere Research Satellite. The multiple scattering model uses the doubling and adding methods to solve the radiative transfer equation, modified to take into account a spherical inhomogeneous atmosphere. Representative absorption and emission line shapes in the O(2)((1)Sigma(+)(g)-(3)Sigma(-)(g)) atmospheric bands (A, B, and gamma) and their variation with altitude are presented. The effects of solar zenith angle, aerosol loading, surface albedo, and cloud height on the line shapes are also discussed.

  15. Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Hao [Department of Engineering Physics, Tsinghua University, Beijing CN-100086 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); The European Organization for Nuclear Research, Geneva CH-1211 (Switzerland); Shi, Jiaru, E-mail: shij@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing CN-100086 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); The European Organization for Nuclear Research, Geneva CH-1211 (Switzerland); Wu, Xiaowei; Chen, Huaibi [Department of Engineering Physics, Tsinghua University, Beijing CN-100086 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2016-04-01

    An experiment is presented to study the higher-order mode (HOM) suppression of X-band choke-mode structures with a vector network analyzer (VNA). Specific radial line disks were built to test the reflection from the corresponding damping load and different choke geometries. The mismatch between the radial lines and the VNA was calibrated through a special multi-short-load calibration method. The measured reflections of different choke geometries showed good agreement with the theoretical calculations and verified the HOM absorption feature of each geometric design.

  16. Higher-order mode absorption measurement of X-band choke-mode cavities in a radial line structure

    Science.gov (United States)

    Zha, Hao; Shi, Jiaru; Wu, Xiaowei; Chen, Huaibi

    2016-04-01

    An experiment is presented to study the higher-order mode (HOM) suppression of X-band choke-mode structures with a vector network analyzer (VNA). Specific radial line disks were built to test the reflection from the corresponding damping load and different choke geometries. The mismatch between the radial lines and the VNA was calibrated through a special multi-short-load calibration method. The measured reflections of different choke geometries showed good agreement with the theoretical calculations and verified the HOM absorption feature of each geometric design.

  17. Optical absorption and refractive index near the band gap for InGaAsP

    International Nuclear Information System (INIS)

    Kowalsky, W.; Wehmann, H.H.; Fiedler, F.; Schlachetzki, A.

    1983-01-01

    The optical absorption coefficient α and the refractive index n were measured for a quaternary alloy with bandgap-equivalent wavelength of 1.17 μm and for the ternary alloy, both lattice-matched to InP. α in dependence on the wavelength is characteristic of a direct semiconductor, but with a relative maximum on the order of 50 meV away from the bandgap in the small-absorption range. This peak is tentatively assigned to an acceptor impurity

  18. Comparative analysis of the vibrational structure of the absorption spectra of acrolein in the excited ( S 1) electronic state

    Science.gov (United States)

    Koroleva, L. A.; Tyulin, V. I.; Matveev, V. K.; Pentin, Yu. A.

    2012-04-01

    The assignments of absorption bands of the vibrational structure of the UV spectrum are compared with the assignments of bands obtained by the CRDS method in a supersonic jet from the time of laser radiation damping for the trans isomer of acrolein in the excited ( S 1) electronic state. The ν00 trans = 25861 cm-1 values and fundamental frequencies, including torsional vibration frequency, obtained by the two methods were found to coincide in the excited electronic state ( S 1) for this isomer. The assignments of several absorption bands of the vibrational structure of the spectrum obtained by the CRDS method were changed. Changes in the assignment of (0-v') transition bands of the torsional vibration of the trans isomer in the Deslandres table from the ν00 trans trans origin allowed the table to be extended to high quantum numbers v'. The torsional vibration frequencies up to v' = 5 were found to be close to the frequencies found by analyzing the vibrational structure of the UV spectrum and calculated quantum-mechanically. The coincidence of the barrier to internal rotation (the cis-trans transition) in the one-dimensional model with that calculated quantum-mechanically using the two-dimensional model corresponds to a planar structure of the acrolein molecule in the excited ( S 1) electronic state.

  19. Strategies to tailor the UV absorption band of Eu3+:La2O3 downshifting nanocrystals

    Science.gov (United States)

    Méndez, M.; Cesteros, Y.; Marsal, L. F.; Salagre, P.; Formentín, P.; Pallarès, J.; Aguiló, M.; Díaz, F.; Carvajal, J. J.

    2012-06-01

    The charge transfer state (CTS) band of the Eu3+:La2O3 nanocrystals were studied in detail in order to understand the shift of the maximum of this band. Eu3+:La2O3 nanoparticles present a broad CTS band. However, the maximum is peaking below 300 nm, far below the limit of the solar spectrum arriving to the surface of the Earth and it makes difficult the application of this material as down-shifting in solar cells. In order to shift the CTS band towards blue wavelengths, different synthesis methods such as hydrothermal and sol-gel modified Pechini methods were used to prepare these nanoparticles, and adding additional CTS bands with co-doping ions such as Bi3+ was explored as well. The crystalline structure of Eu3+:La(OH)3, Eu3+:La2O3, Bi3+:Eu3+:La(OH)3 and Bi3+:Eu3+:La2O3 and the cell parameters of Eu3+:La2O3 and Bi3+:Eu3+:La2O3 were analyzed by X-ray powder diffraction technique and their morphology was observed by transmission electron microscopy. Once we obtained the cell parameters refining the XRD patterns by Full-prof software, we were able to calculate the Eu3+-O distance by ATOMS software through the structure previously represented following the Pauling model. The results found suggest that we need to take into account another parameter apart from the Eu3+-O distance to explain the CTS band small shift.

  20. Propagation losses in photonic crystal waveguides: Effects of band tail absorption and waveguide dispersion

    DEFF Research Database (Denmark)

    Rigal, F.; Joanesarson, Kristoffer Bitsch; Lyasota, A.

    2017-01-01

    Propagation losses in GaAs-based photonic crystal (PhC) waveguides are evaluated near the semiconductor band-edge by measuring the finesse of corresponding Ln cavities. This approach yields simultaneously the propagation losses and the mode reflectivity at the terminations of the cavities. We...... is important for the monolithic integration of light sources with such optical elements....

  1. Strongly correlated quasi-one-dimensional bands: Ground states, optical absorption, and phonons

    International Nuclear Information System (INIS)

    Campbell, D.K.; Gammel, J.T.; Loh, E.Y. Jr.

    1989-01-01

    Using the Lanczos method for exact diagonalization on systems up to 14 sites, combined with a novel ''phase randomization'' technique for extracting more information from these small systems, we investigate several aspects of the one-dimensional Peierls-Hubbard Hamiltonian, in the context of trans-polyacetylene: the dependence of the ground state dimerization on the strength of the electron-electron interactions, including the effects of ''off-diagonal'' Coulomb terms generally ignored in the Hubbard model; the phonon vibrational frequencies and dispersion relations, and the optical absorption properties, including the spectrum of absorptions as a function of photon energy. These three different observables provide considerable insight into the effects of electron-electron interactions on the properties of real materials and thus into the nature of strongly correlated electron systems. 29 refs., 11 figs

  2. Band-gap engineering and comparative investigation of Ti2Nb10O29 photocatalysts obtained by Various synthetic routes

    Science.gov (United States)

    Xie, Meiling; Zhu, Hekai; Fang, Minghao; Huang, Zhaohui; Liu, Yan'gai; Wu, Xiaowen

    2018-03-01

    Ti2Nb10O29 photocatalysts were successfully synthesized by three different methods. Ti2Nb10O29 fabricated by the solvothermal method (ST-TNO) exhibited unique microspheres compared to the larger irregular particles observed for the samples annealed in air (Air-TNO) and Ar (Ar-TNO). X-ray Photoelectron Spectroscopy (XPS) results revealed that a partial reduction process from Ti4+ into Ti3+ occurs in Ar-TNO, because of the introduction of oxygen defects. Ar-TNO exhibited visible-light absorption with a band gap of 2.85 eV, while the absorption edges of Air-TNO and ST-TNO were approximately 400 nm. Under UV light irradiation (λ < 420 nm), Ar-TNO exhibited a photocatalytic activity 2.1 times greater than that of Air-TNO, corresponding to the highest activity. The results indicated that the preparation method is crucial for determining the band gap and photocatalytic activity of semiconductors. Moreover, the novel semiconductor photocatalyst can be further applied for constructing the heterojunction and designing the band structure.

  3. Band alignment and optical absorption in Ga(Sb)N alloys.

    Science.gov (United States)

    Andriotis, Antonis N; Sheetz, R Michael; Richter, Ernst; Menon, Madhu

    2014-02-05

    We extend the theory of band alignment proposed by Harrison to ternary and quaternary heteropolar semiconductors. Combining this with first-principles density functional theory incorporating the LDA/GGA+U formalism (LDA: local density approximation; GGA: generalized gradient approximation) can result in useful electronic structure predictions for new alloys. The practicality of this is demonstrated by application to the Ga(Sbx)N1-x alloys, where the feasibility of water splitting reaction under visible light irradiation is discussed.

  4. Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

    Science.gov (United States)

    Chu, Zhiping; Wilkerson, Thomas D.; Singh, Upendra N.

    1993-01-01

    We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

  5. A Multi-Band Analytical Algorithm for Deriving Absorption and Backscattering Coefficients from Remote-Sensing Reflectance of Optically Deep Waters

    Science.gov (United States)

    Lee, Zhong-Ping; Carder, Kendall L.

    2001-01-01

    A multi-band analytical (MBA) algorithm is developed to retrieve absorption and backscattering coefficients for optically deep waters, which can be applied to data from past and current satellite sensors, as well as data from hyperspectral sensors. This MBA algorithm applies a remote-sensing reflectance model derived from the Radiative Transfer Equation, and values of absorption and backscattering coefficients are analytically calculated from values of remote-sensing reflectance. There are only limited empirical relationships involved in the algorithm, which implies that this MBA algorithm could be applied to a wide dynamic range of waters. Applying the algorithm to a simulated non-"Case 1" data set, which has no relation to the development of the algorithm, the percentage error for the total absorption coefficient at 440 nm a (sub 440) is approximately 12% for a range of 0.012 - 2.1 per meter (approximately 6% for a (sub 440) less than approximately 0.3 per meter), while a traditional band-ratio approach returns a percentage error of approximately 30%. Applying it to a field data set ranging from 0.025 to 2.0 per meter, the result for a (sub 440) is very close to that using a full spectrum optimization technique (9.6% difference). Compared to the optimization approach, the MBA algorithm cuts the computation time dramatically with only a small sacrifice in accuracy, making it suitable for processing large data sets such as satellite images. Significant improvements over empirical algorithms have also been achieved in retrieving the optical properties of optically deep waters.

  6. An Unusual Strong Visible-Light Absorption Band in Red Anatase TiO2 Photocatalyst Induced by Atomic Hydrogen-Occupied Oxygen Vacancies.

    Science.gov (United States)

    Yang, Yongqiang; Yin, Li-Chang; Gong, Yue; Niu, Ping; Wang, Jian-Qiang; Gu, Lin; Chen, Xingqiu; Liu, Gang; Wang, Lianzhou; Cheng, Hui-Ming

    2018-02-01

    Increasing visible light absorption of classic wide-bandgap photocatalysts like TiO 2 has long been pursued in order to promote solar energy conversion. Modulating the composition and/or stoichiometry of these photocatalysts is essential to narrow their bandgap for a strong visible-light absorption band. However, the bands obtained so far normally suffer from a low absorbance and/or narrow range. Herein, in contrast to the common tail-like absorption band in hydrogen-free oxygen-deficient TiO 2 , an unusual strong absorption band spanning the full spectrum of visible light is achieved in anatase TiO 2 by intentionally introducing atomic hydrogen-mediated oxygen vacancies. Combining experimental characterizations with theoretical calculations reveals the excitation of a new subvalence band associated with atomic hydrogen filled oxygen vacancies as the origin of such band, which subsequently leads to active photo-electrochemical water oxidation under visible light. These findings could provide a powerful way of tailoring wide-bandgap semiconductors to fully capture solar light. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Controlling multi-wave mixing signals via photonic band gap of electromagnetically induced absorption grating in atomic media.

    Science.gov (United States)

    Zhang, Yiqi; Wu, Zhenkun; Yao, Xin; Zhang, Zhaoyang; Chen, Haixia; Zhang, Huaibin; Zhang, Yanpeng

    2013-12-02

    We experimentally demonstrate dressed multi-wave mixing (MWM) and the reflection of the probe beam due to electromagnetically induced absorption (EIA) grating can coexist in a five-level atomic ensemble. The reflection is derived from the photonic band gap (PBG) of EIA grating, which is much broader than the PBG of EIT grating. Therefore, EIA-type PBG can reflect more energy from probe than EIT-type PBG does, which can effectively affect the MWM signal. The EIA-type as well as EIT-type PBG can be controlled by multiple parameters including the frequency detunings, propagation angles and powers of the involved light fields. Also, the EIA-type PBG by considering both the linear and third-order nonlinear refractive indices is also investigated. The theoretical analysis agrees well with the experimental results. This investigation has potential applications in all-optical communication and information processing.

  8. Performance of ultrathin silicon solar microcells with nanostructures of relief formed by soft imprint lithography for broad band absorption enhancement.

    Science.gov (United States)

    Shir, Dan; Yoon, Jongseung; Chanda, Debashis; Ryu, Jae-Ha; Rogers, John A

    2010-08-11

    Recently developed classes of monocrystalline silicon solar microcells can be assembled into modules with characteristics (i.e., mechanically flexible forms, compact concentrator designs, and high-voltage outputs) that would be impossible to achieve using conventional, wafer-based approaches. This paper presents experimental and computational studies of the optics of light absorption in ultrathin microcells that include nanoscale features of relief on their surfaces, formed by soft imprint lithography. Measurements on working devices with designs optimized for broad band trapping of incident light indicate good efficiencies in energy production even at thicknesses of just a few micrometers. These outcomes are relevant not only to the microcell technology described here but also to other photovoltaic systems that benefit from thin construction and efficient materials utilization.

  9. Electromagnetic and Microwave Absorption Properties of the Flake-Shaped Pr-Ho-Fe Alloys in the C-Band

    Science.gov (United States)

    Luo, Jialiang; Pan, Shunkang; Qiao, Ziqiang; Cheng, Lichun; Wang, Zhenzhong; Lin, Peihao; Chang, Junqing

    2018-01-01

    The polycrystalline samples Pr x Ho2- x Fe17 ( x = 0.0, 0.1, 0.2, 0.3, 0.4) were prepared by arc melting and high-energy ball milling method. The influences of Pr substitution on phase structure, morphology, saturation magnetization and electromagnetic parameters were investigated by x-ray diffraction, scanning electron microscopy, vibrating-sample magnetometry and vector network analyzer, respectively. The results show that the particle size increased and the saturation magnetization decreased with increasing Pr content. The minimum absorption peak frequency shifted towards a lower-frequency region with increasing Pr concentration. The minimum RL of Pr0.3Ho1.7Fe17 powder was -41.03 dB at 6.88 GHz with a coating thickness of 2.0 mm. With different thickness of 1.8-2.8 mm, the minimum reflection loss (RL) of Pr0.3Ho1.7Fe17 powder was less than -20 dB in the whole C-band (4-8 GHz). The microwave-absorbing properties of the composite with different weight ratios of Pr0.3Ho1.7Fe17/Co were researched. The microwave-absorbing peaks of the composites shifted to a lower frequency with increasing Co content. The minimum RL of Pr0.3Ho1.7Fe17/Co(10%) was -42.51 dB at 4.72 GHz with a coating thickness of 2.6 mm. This suggests that the Pr-Ho-Fe will be a promising microwave absorption material in higher-gigahertz frequency, especially in the C-band.

  10. Incoherent broad-band cavity-enhanced absorption spectroscopy of the marine boundary layer species I2, IO and OIO.

    Science.gov (United States)

    Vaughan, Stewart; Gherman, Titus; Ruth, Albert A; Orphal, Johannes

    2008-08-14

    The novel combination of incoherent broad-band cavity-enhanced absorption spectroscopy (IBBCEAS) and a discharge-flow tube for the study of three key atmospheric trace species, I(2), IO and OIO, is reported. Absorption measurements of I(2) and OIO at lambda=525-555 nm and IO at lambda=420-460 nm were made using a compact cavity-enhanced spectrometer employing a 150 W short-arc Xenon lamp. The use of a flow system allowed the monitoring of the chemically short-lived radical species IO and OIO to be conducted over timescales of several seconds. We report detection limits of approximately 26 pmol mol(-1) for I(2) (L=81 cm, acquisition time 60 s), approximately 45 pmol mol(-1) for OIO (L=42.5 cm, acquisition time 5 s) and approximately 210 pmol mol(-1) for IO (L=70 cm, acquisition time 60 s), demonstrating the usefulness of this approach for monitoring these important species in both laboratory studies and field campaigns.

  11. Visible-band (390-940nm) monitoring of the Pluto absorption spectrum during the New Horizons encounter

    Science.gov (United States)

    Smith, Robert J.; Marchant, Jonathan M.

    2015-11-01

    Whilst Earth-based observations obviously cannot compete with New Horizons’ on-board instrumentation in most regards, the New Horizons data set is essentially a snapshot of Pluto in July 2015. The New Horizons project team therefore coordinated a broad international observing campaign to provide temporal context and to take advantage of the once-in-a-lifetime opportunity to directly link our Earth-based view of Pluto with “ground truth” provided by in situ measurements. This both adds value to existing archival data sets and forms the basis of long term, monitoring as we watch Pluto recede from the Sun over the coming years. We present visible-band (390-940nm) monitoring of the Pluto absorption spectrum over the period July - October 2015 from the Liverpool Telescope (LT). In particular we wished to understand the well-known 6-day fluctuation in the methane ice absorption spectrum which is observable from Earth in relation to the never-before-available high resolution maps of the Pluto surface. The LT is a fully robotic 2.0m optical telescope that automatically and dynamically schedules observations across 30+ observing programmes with a broad instrument suite. It is ideal for both reactive response to dynamic events (such as the fly-by) and long term, stable monitoring with timing constraints individually optimised to the science requirements of each programme. For example past studies of the observed CH4 absorption variability have yielded ambiguity of whether they were caused by real physical changes or geometric observation constraints, in large part because of the uneven time sampling imposed by traditional telescope scheduling.

  12. Ultrafast Time-Resolved Emission and Absorption Spectra of meso-Pyridyl Porphyrins upon Soret Band Excitation Studied by Fluorescence Up-Conversion and Transient Absorption Spectroscopy.

    Science.gov (United States)

    Venkatesh, Yeduru; Venkatesan, M; Ramakrishna, B; Bangal, Prakriti Ranjan

    2016-09-08

    A comprehensive study of ultrafast molecular relaxation processes of isomeric meso-(pyridyl) porphyrins (TpyPs) has been carried out by using femtosecond time-resolved emission and absorption spectroscopic techniques upon pumping at 400 nm, Soret band (B band or S2), in 4:1 dichloromethane (DCM) and tetrahydrofuran (THF) solvent mixture. By combined studies of fluorescence up-conversion, time-correlated single photon counting, and transient absorption spectroscopic techniques, a complete model with different microscopic rate constants associated with elementary processes involved in electronic manifolds has been reported. Besides, a distinct coherent nuclear wave packet motion in Qy state is observed at low-frequency mode, ca. 26 cm(-1) region. Fluorescence up-conversion studies constitute ultrafast time-resolved emission spectra (TRES) over the whole emission range (430-710 nm) starting from S2 state to Qx state via Qy state. Careful analysis of time profiles of up-converted signals at different emission wavelengths helps to reveal detail molecular dynamics. The observed lifetimes are as indicated: A very fast decay component with 80 ± 20 fs observed at ∼435 nm is assigned to the lifetime of S2 (B) state, whereas being a rise component in the region of between 550 and 710 nm emission wavelength pertaining to Qy and Qx states, it is attributed to very fast internal conversion (IC) occurring from B → Qy and B → Qx as well. Two distinct components of Qy emission decay with ∼200-300 fs and ∼1-1.5 ps time constants are due to intramolecular vibrational redistribution (IVR) induced by solute-solvent inelastic collisions and vibrational redistribution induced by solute-solvent elastic collision, respectively. The weighted average of these two decay components is assigned as the characteristic lifetime of Qy, and it ranges between 0.3 and 0.5 ps. An additional ∼20 ± 2 ps rise component is observed in Qx emission, and it is assigned to the formation time of

  13. Evidence for the presence of the 802.7/cm band Q branch of HO2NO2 in high resolution solar absorption spectra of the stratosphere

    Science.gov (United States)

    Rinsland, C. P.; Zander, R.; Farmer, C. B.; Norton, R. H.; Brown, L. R.; Russell, J. M., III; Park, J. H.

    1986-08-01

    Stratospheric solar absorption spectra recorded at ≡0.01 cm-1 resolution by the ATMOS (Atmospheric Trace Molecule Spectroscopy) Fourier transform spectrometer during the Spacelab 3 Shuttle mission show a weak absorption feature covering ≡802.5 - 803.3 cm-1. The authors identify this feature as the unresolved Q branch of the 802.7 cm-1 band of HO2NO2 and report profiles for 31°N and 47°S.

  14. Comparative study of sound absorption coefficient determination using FEM method and experimental tests on Kundt's tube

    Science.gov (United States)

    Deaconu, Marius; Toma, Adina Cristina; Dragasanu, Luminita Ioana; Mihai, Dragos

    2017-06-01

    Sound absorption coefficient is a commonly used parameter to characterize the acoustic properties of sound absorbing materials that plays an important role in noise attenuation. For this study a specific material has been chosen in order to be evaluated experimentally and compared with the simulated results. Both simulation and experimental assessments used to estimate the sound absorption coefficient are based on transfer function method in accordance with standard SR EN JSO 10354-2. Results are obtained for 15, 30, 45 mm material sample thickness in order to assess the relationship between absorption coefficient, thickness and frequency response. Comparative analysis is performed to determine differences given by the two approaches.

  15. Effect of thickness on microwave absorptive behavior of La-Na doped Co-Zr barium hexaferrites in 18.0–26.5 GHz band

    Energy Technology Data Exchange (ETDEWEB)

    Arora, Amit [D.A.V. Institute of Engineering and Technology, Jalandhar (India); Narang, Sukhleen Bindra, E-mail: sukhleen2@yahoo.com [Department of Electronics Technology, Guru Nanak Dev University, Amritsar (India); Pubby, Kunal [Department of Electronics Technology, Guru Nanak Dev University, Amritsar (India)

    2017-02-01

    In this research, the microwave properties of Lanthanum-Sodium doped Cobalt-Zirconium barium hexaferrites, intended as microwave absorbers, are analyzed on Vector Network Analyzer in K-band. The results indicate that the doping has resulted in lowering of real permittivity and enhancement of dielectric losses. Real permeability has shown increase while magnetic losses have shown decrease in value with doping. All these four properties have shown very small variation with frequency in the scanned frequency range which indicates the relaxation type of behavior. Microwave absorption characteristics of these compositions are analyzed with change in sample thickness. The results demonstrate that the matching frequency of the microwave absorber shifts towards lower side of frequency band with increase in thickness. The complete analysis of the prepared microwave absorbers shows a striking achievement with very low reflection loss and wide absorption bandwidth for all the six compositions in 18–26.5 GHz frequency band. - Highlights: • Electromagnetic Characterization of M-hexaferrites in K-band (18–26.5 GHz) • Variation of absorption properties with thickness of sample. • Satisfaction of quarter-wavelength condition for absorption properties • Results of double-layer absorbers (not reports till day by anyone).

  16. Infrared absorption spectra of gaseous HD. II. Collision-induced fundamental band of HD in HD--Ne and HD--Ar mixtures at room temperature

    International Nuclear Information System (INIS)

    Prasad, R.D.G.; Reddy, S.P.

    1976-01-01

    The collision-induced infrared absorption spectra of the fundamental band of HD in binary mixtures of HD with Ne and Ar at room temperature have been studied with an absorption path length of 105.2 cm for different base densities of HD in the range 8--20 amagat and a number of total gas densities up to 175 amagat. The observed features of the profiles of the enhancement of absorption in these mixtures resemble closely those of the corresponding profiles of the fundamental band of H 2 in binary mixtures with Ne and Ar. The binary absorption coefficients of the band obtained from the measured integrated intensities are (1.84 +- 0.06) x 10 -35 and (4.41 +- 0.06) x 10 -35 cm 6 s -1 for HD--Ne and HD--Ar, respectively. The characteristic half-width parameters, delta/subd/ and delta/subc/ of the overlap transitions and delta/subq/ (and delta/subq//sub prime/) of the quadrupolar transitions, are obtained from an analysis of the profiles of the enhancement of absorption in both these mixtures. The quantity delta/subc/ which is the half-width of the intercollisional interference dip of the Q branch increases with the density of the perturbing gas Ne or Ar, and for HD--Ne it varies in a manner similar to that for HD--He as described in Paper I of this series

  17. Comparative Investigation of the Efficiency of Absorption of Solar Energy by Carbon Composite Materials

    Science.gov (United States)

    Prikhod‧ko, N. G.; Smagulova, G. T.; Rakhymzhan, N. B.; Kim, S.; Lesbaev, B. T.; Nazhipkyzy, M.; Mansurov, Z. A.

    2017-01-01

    This paper presents the results of research on the efficiency of absorption of solar energy by various carbon materials (soot, carbonized apricot pits and rice husks, and carbon nanotubes in the form of a ″forest″), as well as by composites based on them with inclusions of metal oxide nanoparticles. An analysis of the efficiency of absorption of solar energy by various carbon materials has demonstrated the advantage of the carbon material from carbonized apricot pits. The results of the comparative investigation of the absorptivity of apricot pits with that of the coating of a production prototype of solar collector are presented.

  18. Oral iron therapy in human subjects, comparative absorption between ferrous salts and iron polymaltose

    International Nuclear Information System (INIS)

    Jacobs, P.; Johnson, G.; Wood, L.

    1984-01-01

    Iron absorption was directly compared between equivalent doses of ferrous salts and a polymaltose complex using a twin-isotope technique in which each individual acts as his own control. In the first study, bioavailability of iron from ferrous sulfate and the complex was defined at physiologic doses of 5 mg (Group 1: n = 14) and therapeutic doses of 50 mg (Group 2: n = 13). In Group 1, mean absorption from salt was 47.77% (SD 14.58%) and from polymaltose, 46.56% SD 17.07%). In Group 2, mean absorption from salt was 32.92% (SD 13.42%) and from polymaltose, 27.07% (SD 6.50%). In a second study, 100 mg of iron in a chewable formulation was used to compare absorption between equal doses of ferrous fumarate and the polymaltose complex. Mean absorption from salt was 10.25% (SD 6.89%) and from polymaltose 10.68% (SD 4.68%). At all three dosage levels, iron is equally available from salt or polymaltose for hemoglobin synthesis (p greater than 0.20), and absorption negatively correlated with plasma ferritin (p less than 0.01). These two materials may be used interchangeably in the treatment of patients with absolute iron deficiency

  19. Modeled and Empirical Approaches for Retrieving Columnar Water Vapor from Solar Transmittance Measurements in the 0.72, 0.82, and 0.94 Micrometer Absorption Bands

    Science.gov (United States)

    Ingold, T.; Schmid, B.; Maetzler, C.; Demoulin, P.; Kaempfer, N.

    2000-01-01

    A Sun photometer (18 channels between 300 and 1024 nm) has been used for measuring the columnar content of atmospheric water vapor (CWV) by solar transmittance measurements in absorption bands with channels centered at 719, 817, and 946 nm. The observable is the band-weighted transmittance function defined by the spectral absorption of water vapor and the spectral features of solar irradiance and system response. The transmittance function is approximated by a three-parameter model. Its parameters are determined from MODTRAN and LBLRTM simulations or empirical approaches using CWV data of a dual-channel microwave radiometer (MWR) or a Fourier transform spectrometer (FTS). Data acquired over a 2-year period during 1996-1998 at two different sites in Switzerland, Bern (560 m above sea level (asl)) and Jungfraujoch (3580 m asl) were compared to MWR, radiosonde (RS), and FTS retrievals. At the low-altitude station with an average CWV amount of 15 mm the LBLRTM approach (based on recently corrected line intensities) leads to negligible biases at 719 and 946 nm if compared to an average of MWR, RS, and GPS retrievals. However, at 817 nm an overestimate of 2.7 to 4.3 mm (18-29%) remains. At the high-altitude station with an average CWV amount of 1.4 mm the LBLRTM approaches overestimate the CWV by 1.0, 1.4. and 0.1 mm (58, 76, and 3%) at 719, 817, and 946 nm, compared to the ITS instrument. At the low-altitude station, CWV estimates, based on empirical approaches, agree with the MWR within 0.4 mm (2.5% of the mean); at the high-altitude site with a factor of 10 less water vapor the agreement of the sun photometers (SPM) with the ITS is 0.0 to 0.2 mm (1 to 9% of the mean CWV there). Sensitivity analyses show that for the conditions met at the two stations with CWV ranging from 0.2 to 30 mm, the retrieval errors are smallest if the 946 nm channel is used.

  20. A comparative in vivo and in vitro L-band EPR study of irradiated rat incisors

    International Nuclear Information System (INIS)

    Zdravkova, M.; Gallez, B.; Debuyst, R.

    2005-01-01

    L-band (∼1GHz) EPR has the potential to measure the absorbed radiation dose in human teeth inside the mouth (in vivo analyses). One crucial point in the development of the method is to know if dosimetry evaluation carried out in vivo after accidental exposures can be reliably based on calibration curves built in vitro. The aim of the present work is to specifically address this point. First, we compared L-band in vitro and in vivo analyses in irradiated rat teeth and estimated the possible loss in in vivo experiments due to rat movements and mouth proximity. Second, the lower pair of rat incisors were analysed by L-band EPR before and after irradiation (50Gy), first on the living rat, then on the same dead rat, finally after extraction of the teeth. X-band powder spectra were also taken after crushing of the two teeth. Irradiations of dead rats and extracted teeth were also carried out. Comparing L-band spectra obtained with living rats and removed heads does not show any significant difference due to possible small rat movements or breathing. Relative standard deviations of the amplitudes of the dosimetric signal are quite high (27-54%). Nevertheless, it seems to be a tendency to have higher signals in irradiated extracted teeth than in irradiated animals

  1. Analysis of the intermediate-band absorption properties of type-II GaSb/GaAs quantum-dot photovoltaics

    Science.gov (United States)

    Ramiro, I.; Villa, J.; Tablero, C.; Antolín, E.; Luque, A.; Martí, A.; Hwang, J.; Phillips, J.; Martin, A. J.; Millunchick, J.

    2017-09-01

    Quantum-dot (QD) intermediate-band (IB) materials are regarded as promising candidates for high-efficiency photovoltaics. The sequential two-step two-photon absorption processes that take place in these materials have been proposed to develop high-efficiency solar cells and infrared (IR) photodetectors. In this work, we experimentally and theoretically study the interrelation of the absorptivity with transitions of carriers to and from the IB in type-II GaSb/GaAs QD devices. Our devices exhibit three optical band gaps with: EL=0.49 eV ,EH=1.02 eV , and EG=1.52 eV , with the IB located 0.49 eV above the valence band. These values are well supported by semiempirical calculations of the QDs electronic structure. Through intensity-dependent two-photon photocurrent experiments, we are able to vary the filling state of the IB, thus modifying the absorptivity of the transitions to and from this band. By filling the IB with holes via E =1.32 eV or E =1.93 eV monochromatic illumination, we demonstrate an increase in the EL-related absorptivity of more than two orders of magnitude and a decrease in the EH-related absorptivity of one order of magnitude. The antisymmetrical evolution of those absorptivities is quantitatively explained by a photoinduced shift of the quasi-Fermi level of the IB. Furthermore, we report the observation of a two-photon photovoltage, i.e., the contribution of subband gap two-photon absorption to increase the open-circuit voltage of solar cells. We find that the generation of the two-photon photovoltage is related, in general, to the production of a two-photon photocurrent. However, while photons with energy close to EL participate in the production of the two-photon photocurrent, they are not effective in the production of a two-photon photovoltage. We also report the responsivity of GaSb/GaAs QD devices performing as optically triggered photodetectors. These devices exhibit an amplification factor of almost 400 in the IR spectral region. This high

  2. Model parameterization to simulate and compare the PAR absorption potential of two competing plant species.

    Science.gov (United States)

    Bendix, Jörg; Silva, Brenner; Roos, Kristin; Göttlicher, Dietrich Otto; Rollenbeck, Rütger; Nauss, Thomas; Beck, Erwin

    2010-05-01

    Mountain pastures dominated by the pasture grass Setaria sphacelata in the Andes of southern Ecuador are heavily infested by southern bracken (Pteridium arachnoideum), a major problem for pasture management. Field observations suggest that bracken might outcompete the grass due to its competitive strength with regard to the absorption of photosynthetically active radiation (PAR). To understand the PAR absorption potential of both species, the aims of the current paper are to (1) parameterize a radiation scheme of a two-big-leaf model by deriving structural (LAI, leaf angle parameter) and optical (leaf albedo, transmittance) plant traits for average individuals from field surveys, (2) to initialize the properly parameterized radiation scheme with realistic global irradiation conditions of the Rio San Francisco Valley in the Andes of southern Ecuador, and (3) to compare the PAR absorption capabilities of both species under typical local weather conditions. Field data show that bracken reveals a slightly higher average leaf area index (LAI) and more horizontally oriented leaves in comparison to Setaria. Spectrometer measurements reveal that bracken and Setaria are characterized by a similar average leaf absorptance. Simulations with the average diurnal course of incoming solar radiation (1998-2005) and the mean leaf-sun geometry reveal that PAR absorption is fairly equal for both species. However, the comparison of typical clear and overcast days show that two parameters, (1) the relation of incoming diffuse and direct irradiance, and (2) the leaf-sun geometry play a major role for PAR absorption in the two-big-leaf approach: Under cloudy sky conditions (mainly diffuse irradiance), PAR absorption is slightly higher for Setaria while under clear sky conditions (mainly direct irradiance), the average bracken individual is characterized by a higher PAR absorption potential. (approximately 74 MJ m(-2) year(-1)). The latter situation which occurs if the maximum daily

  3. Laparoscopic adjustable gastric banding. A prospective randomized study comparing the Swedish Adjustable Gastric Band and the MiniMizer Extra: one-year results

    Directory of Open Access Journals (Sweden)

    Tomas Abalikšta

    2011-12-01

    Full Text Available Introduction: A number of different adjustable gastric bands are available for laparoscopic adjustable gastric banding(LAGB. Few attempts have been made to compare the influence of band design differences for efficiency and complicationrate and conflicting results have emerged from comparative studies. Aim: To compare SAGB (Swedish Adjustable Gastric Band and MiniMizer Extra adjustable gastric bands. Material and methods: One hundred and three patients were included in the prospective randomized study. Allpatients underwent LAGB. The SAGB was used in 49 and MiniMizer Extra in 54 patients. The primary endpoint wasweight loss, and secondary endpoints were complication rate, correction of co-morbidities and improvement of qualityof life. Results: There were no early complications. A significant difference in the proportion of patients who have reachedgood or excellent weight loss results (≥ 50% of initial excess body mass index loss was found in favour of the Mini-Mizer Extra group (29.6% vs. 8.2%, p = 0.006. No difference was found in other weight loss parameters, resolution ofco-morbidities and improvement of quality of life. One oesophageal dilatation and one leakage were diagnosed in theMiniMizer Extra group. Five band penetrations (9.3% were diagnosed in the MiniMizer Extra group and no penetrationsin the SAGB group (p = 0.069. Conclusions: No major significant differences were found between the compared bands. Further results need to beconfirmed by longer follow-up.

  4. High-performance ternary blend all-polymer solar cells with complementary absorption bands from visible to near-infrared wavelengths

    OpenAIRE

    Benten, Hiroaki; Nishida, Takaya; Mori, Daisuke; Xu, Huajun; Ohkita, Hideo; Ito, Shinzaburo

    2016-01-01

    We developed high-performance ternary blend all-polymer solar cells with complementary absorption bands from visible to near-infrared wavelengths. A power conversion efficiency of 6.7% was obtained with an external quantum efficiency over 60% both in the visible and near-infrared regions. Our results demonstrate that the ternary blend all-polymer systems open a new avenue for accelerating improvement in the efficiency of non-fullerene thin-film polymer solar cells.

  5. A study of the structure of the ν1(HF) absorption band of the СH3СN…HF complex

    Science.gov (United States)

    Gromova, E. I.; Glazachev, E. V.; Bulychev, V. P.; Koshevarnikov, A. M.; Tokhadze, K. G.

    2015-09-01

    The ν1(HF) absorption band shape of the CH3CN…HF complex is studied in the gas phase at a temperature of 293 K. The spectra of gas mixtures CH3CN/HF are recorded in the region of 4000-3400 cm-1 at a resolution from 0.1 to 0.005 cm-1 with a Bruker IFS-120 HR vacuum Fourier spectrometer in a cell 10 cm in length with wedge-shaped sapphire windows. The procedure used to separate the residual water absorption allows more than ten fine-structure bands to be recorded on the low-frequency wing of the ν1(HF) band. It is shown that the fine structure of the band is formed primarily due to hot transitions from excited states of the low-frequency ν7 librational vibration. Geometrical parameters of the equilibrium nuclear configuration, the binding energy, and the dipole moment of the complex are determined from a sufficiently accurate quantum-chemical calculation. The frequencies and intensities for a number of spectral transitions of this complex are obtained in the harmonic approximation and from variational solutions of anharmonic vibrational problems.

  6. Compression of Multispectral Images with Comparatively Few Bands Using Posttransform Tucker Decomposition

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Up to now, data compression for the multispectral charge-coupled device (CCD images with comparatively few bands (MSCFBs is done independently on each multispectral channel. This compression codec is called a “monospectral compressor.” The monospectral compressor does not have a removing spectral redundancy stage. To fill this gap, we propose an efficient compression approach for MSCFBs. In our approach, the one dimensional discrete cosine transform (1D-DCT is performed on spectral dimension to exploit the spectral information, and the posttransform (PT in 2D-DWT domain is performed on each spectral band to exploit the spatial information. A deep coupling approach between the PT and Tucker decomposition (TD is proposed to remove residual spectral redundancy between bands and residual spatial redundancy of each band. Experimental results on multispectral CCD camera data set show that the proposed compression algorithm can obtain a better compression performance and significantly outperforms the traditional compression algorithm-based TD in 2D-DWT and 3D-DCT domain.

  7. Comparative investigation on designs of light absorption enhancement of ultrathin crystalline silicon for photovoltaic applications

    Science.gov (United States)

    Huang, Yi; Wang, Wei; Pan, Wu; Chen, Weizhong; Wang, Zhen; Tan, Xinyu; Yan, Wensheng

    2016-10-01

    Ultrathin crystalline silicon wafers for photovoltaic applications have attracted intensive attention because of potential benefits in cost-effectiveness. Structural design with high light absorption is important for photovoltaics because planar ultrathin silicon is poor in absorption. We conduct a comparative investigation on designs of light absorption enhancement for 2-μm-thick ultrathin crystalline silicon, where the front texture is a nanopyramidal structure and the rear adopts several designs. Our calculation results show that both of the ultrathin silicon with front nanopyramids and rear silver nanoarrays and the ultrathin silicon with two-sided nanopyramids are promising for photovoltaic applications. For the latter design, the calculated photocurrent achieves the highest value of 35.1 mA/cm2 when a perfect electric conductor layer is applied at the bottom. In contrast, the former design has a lower photocurrent value of 31.2 mA/cm2. But, this design is of practical significance because the majority of experimental reports on ultrathin crystalline silicon solar cells are single-sided front-textured at present and the fabrication techniques of plasmonic Ag nanoarrays are matured. Compared with previous reports, the present work offers a multiple option of structural designs for ultrathin crystalline silicon to enhance the light absorption for photovoltaic applications.

  8. Exergy-analysis based comparative study of absorption refrigeration and electric compression refrigeration in CCHP systems

    International Nuclear Information System (INIS)

    Li, Yajun; Hu, Rentian

    2016-01-01

    Highlights: • Performs a comparative study between two different refrigeration systems in CCHP. • Focuses on the impact of steam transport distance on energy and exergy efficiency. • The choice of refrigeration system in CCHP under given conditions is presented. - Abstract: Fueling with natural gas, combined cooling, heating and power (CCHP) system is expected to be widely applied in China, for its potential on energy efficiency and CO 2 emissions reduction. In the design of CCHP, the choice of refrigeration system is now a hot topic because it greatly influences the performance. This paper has made a comparative study between the absorption refrigeration system and electric compression refrigeration system, in terms of exergy efficiency of refrigeration system in CCHP and energy efficiency of CCHP. A GE 9171E gas–steam combined cycle based CCHP system is chosen and analyzed as an example. The comparative study shows that the distance between power station and refrigeration station, namely the steam transport distance, has an effect on the performances of absorption refrigeration system in CCHP and CCHP based on it. As a result, under the conditions studied, absorption refrigeration is more effective when the distance is shorter than 5 km, and if longer than 9.3 km, electric compression refrigeration is a better choice. With distance between 5 and 9.3 km, the kind of refrigeration should depend on specific conditions. This paper does make important guiding significance for the choice of refrigeration system in the design of CCHP.

  9. Intestinal absorption of aloin, aloe-emodin, and aloesin; A comparative study using two in vitro absorption models.

    Science.gov (United States)

    Park, Mi-Young; Kwon, Hoon-Jeong; Sung, Mi-Kyung

    2009-01-01

    Aloe products are one of the top selling health-functional foods in Korea, however the adequate level of intake to achieve desirable effects are not well understood. The objective of this study was to determine the intestinal uptake and metabolism of physiologically active aloe components using in vitro intestinal absorption model. The Caco-2 cell monolayer and the everted gut sac were incubated with 5-50 microM of aloin, aloe-emodin, and aloesin. The basolateral appearance of test compounds and their glucuronosyl or sulfated forms were quantified using HPLC. The % absorption of aloin, aloe-emodin, and aloesin was ranged from 5.51% to 6.60%, 6.60% to 11.32%, and 7.61% to 13.64%, respectively. Up to 18.15%, 18.18%, and 38.86% of aloin, aloe-emodin, and aloesin, respectively, was absorbed as glucuronidated or sulfated form. These results suggest that a significant amount is transformed during absorption. The absorption rate of test compounds except aloesin was similar in two models; more aloesin was absorbed in the everted gut sac than in the Caco-2 monolayer. These results provide information to establish adequate intake level of aloe supplements to maintain effective plasma level.

  10. Ultraviolet and infrared absorption spectra of Cr2O3 doped-sodium metaphosphate, lead metaphosphate and zinc metaphosphate glasses and effects of gamma irradiation: a comparative study.

    Science.gov (United States)

    Marzouk, M A; ElBatal, F H; Abdelghany, A M

    2013-10-01

    The effects of gamma irradiation on spectral properties of Cr2O3-doped phosphate glasses of three varieties, namely sodium metaphosphate, lead metaphosphate and zinc metaphosphate have been investigated. Optical spectra of the undoped samples reveal strong UV absorption bands which are attributed to the presence of trace iron impurities in both the sodium and zinc phosphate glasses while the lead phosphate glass exhibits broad UV near visible bands due to combined absorption of both trace iron impurities and divalent lead ions. The effect of chromium oxide content has been investigated. The three different Cr2O3-doped phosphate glasses reveal spectral visible bands varying in their position and intensity and splitting due to the different field strengths of the Na(+), Pb(2+), Zn(2+) cations, together with the way they are housed in the network and their effects on the polarisability of neighboring oxygens ligands. The effects of gamma irradiation on the optical spectral properties of the various glasses have been compared. The different effects for lead and zinc phosphate are related to the ability of Pb(2+), and Zn(2+) to form additional structural units causing stability of the network towards gamma irradiation. Also, the introduction of the transition metal chromium ions reveals some shielding behavior towards irradiation. Infrared absorption spectra of the three different base phosphate glasses show characteristic vibrations due to various phosphate groups depending on the type of glass and Cr2O3 is observed to slightly affect the IR spectra. Gamma irradiation causes minor variations in some of the intensities of the IR spectra but the main characteristic bands due to phosphate groups remain in their number and position. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Comparative QSAR studies on PAMPA/modified PAMPA for high throughput profiling of drug absorption potential with respect to Caco-2 cells and human intestinal absorption

    Science.gov (United States)

    Verma, Rajeshwar P.; Hansch, Corwin; Selassie, Cynthia D.

    2007-01-01

    Despite the dramatic increase in speed of synthesis and biological evaluation of new chemical entities, the number of compounds that survive the rigorous processes associated with drug development is low. Thus, an increased emphasis on thorough ADMET (absorption, distribution, metabolism, excretion and toxicity) studies based on in vitro and in silico approaches allows for early evaluation of new drugs in the development phase. Artificial membrane permeability measurements afford a high throughput, relatively low cost but labor intensive alternative for in vitro determination of drug absorption potential; parallel artificial membrane permeability assays have been extensively utilized to determine drug absorption potentials. The present study provides comparative QSAR analysis on PAMPA/modified PAMPA for high throughput profiling of drugs with respect to Caco-2 cells and human intestinal absorption.

  12. Intestinal absorption of calcium from foodstuffs as compared to a pharmaceutical preparation.

    Science.gov (United States)

    Werner, E; Hansen, Ch; Roth, P; Kaltwasser, J P

    1999-01-01

    Only few data are available on intestinal calcium absorption from foodstuffs and composite meals in humans. The aim of the study was to compare intraindividually the calcium absorption from milk and from a breakfast with that from a pharmaceutical calcium preparation of equal calcium content. In 8 healthy volunteers between 44 and 58 years of age, the intestinal calcium absorption was measured in randomized order applying the double isotope technique from: (1) 500ml of fresh milk (equivalent to 620mg Ca), (2) a test meal composed of 250 g curd, 150g yoghurt, 3 slices pineapple, 2 breakfast rolls, 2 cups of coffee, 10g of coffee cream, 20g butter, 50g jam and 20g honey (equivalent to 580mg Ca), and (3) a lactogluconate effervescent tablet (equivalent to 500mgCa). All test doses were given on an empty stomach and labelled with 20mg 44Ca. Simultaneously, 5mg 42Ca in a sterile isotonic solution were injected intravenously. The mean values of the absorbed fractions are 24.0% +/- 5.4% (mean +/-SD), 17.9% +/- 7.1%, and 28.7% +/- 9.1% for the milk, for the meal and for the tablet respectively. The data show that less calcium is absorbed from foodstuffs as compared to a preparation of optimal bioavailability. But in this study only the difference between absorption from the milk and from the meal was statistically significant. Therefore, it is possible to obtain a sufficient calcium supply of the human body also by properly selected foodstuffs.

  13. Effect of Co substitution on absorption properties of SrCoxFe12-xO19 hexagonal ferrites based nanocomposites in X-band

    Science.gov (United States)

    Chakraborty, Soma; Bhattacharyya, Nidhi Saxena; Bhattacharyya, Satyajib

    2017-12-01

    Cobalt doped M-type strontium hexaferrite nanoparticles (SrCoxFe12-xO19, x = 0.2-1.2) is synthesized and used as inclusions in Linear Low Density Polyethylene (LLDPE) matrix for developing nano-composites with 60 wt% of these nanoparticles. Absorption performance of the developed nano-composites is evaluated in the X-band. The thickness optimization is carried out for obtaining maximum reflection loss by using the transmission line model (TLM), with measured values of permittivity and permeability of the composite. The best reflection loss is observed experimentally for x = 0.8 with an absorber thickness of 3 mm for which a wide -10 dB bandwidth covering almost the entire X-band is obtained. The composites are light weight and not affected by exposure to water.

  14. Comparative Absorption and Emission Abundance Analyses of Nebulae: Ion Emission Densities for IC 418

    Science.gov (United States)

    Williams, Robert; Jenkins, Edward B.; Baldwin, Jack A.; Sharpee, Brian

    2003-02-01

    Recent analyses of nebular spectra have resulted in discrepant abundances from CNO forbidden and recombination lines. We consider independent methods of determining ion abundances for emission nebulae, comparing ion emission measures with column densities derived from resonance absorption lines viewed against the central star continuum. Separate analyses of the nebular emission lines and the stellar UV absorption lines yield independent abundances for ions, and their ratio can be expressed in terms of a parameter em, the ``emission density'' for each ion. Adequate data for this technique are still scarce, but separate analyses of spectra of the planetary nebula and central star of IC 418 do show discrepant abundances for several ions, especially Fe II. The discrepancies are probably due to the presence of absorbing gas that does not emit and/or to uncertain atomic data and excitation processes, and they demonstrate the importance of applying the technique of combining emission- and absorption-line data in deriving abundances for nebulae. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained from the STScI, which is operated by AURA, Inc., under NASA contract NAS 5-26555, and on observations made at CTIO/NOAO, which is operated by AURA, Inc., under cooperative agreement with the NSF.

  15. Previously unreported intense absorption band and the pK/sub A/ of protonated triplet methylene blue

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, T.; Osif, T.L.; Lichtin, N.N.

    1979-01-01

    Excitation by a Q-switched giant ruby laser (1.2 joule output at 694 nm, approx. 50 nsec flash) of 2-10 ..mu..M solutions of methylene blue in water, 30% ethanol in water or 50 v/v% water - CH/sub 3/CN at pH values in the range 2.0 - 9.3 converted the dye essentially completely to its T/sub 1/ state. The absorption spectrum of T/sub 1/ dye was measured in different media at pH 2.0 and 8.2 by kinetic spectrophotometry. Previously reported T-T absorption in the violet in acidic and alkaline solutions and in the near infrared in alkaline solution was confirmed. Values found for these absorptions in the present work with 30% ethanol in water as solvent are lambda/sub max/ approx. 370 nm, epsilon/sub max/ approx. 13,200 M/sup -1/ cm/sup -1/ at pH 2 and lambda/sub max/ approx. 420 nm, epsilon/sub max/ approx. 9,000 M/sup -1/ cm/sup -1/, lambda/sub max/ approx. 840 nm, epsilon/sub max/ approx. 20,000 M/sup -1/ cm/sup -1/ at pH 8.2. Long-wavelength T-T absorption in acidic solution is reported here for the first time: lambda/sub max/ approx. 680 nm, epsilon/sub max/ approx. 19,000 M/sup -1/ cm/sup -1/ in 30% ethanol in water at pH 2. Observation of a pH-independent isobestic point approx. 720 nm confirms that the long-wavelength absorptions are due to different protonated states of the same species, MB/sup +/(T/sub 1/) and MBH/sup 2 +/(T/sub 1/). The pK/sub A/ of MBH/sup 2 +/(T/sub 1/) in water was determined from the dependence on pH of absorption at 700 and 825 nm to be 7.1/sub 4/ +- .1 and from the kinetics of decay of triplet absorption to be 7.2. The specific rate of protonation of MB/sup +/(T/sub 1/) by H/sub 2/PO/sub 4//sup -/ in water at pH 4.4 was found to be 4.5 +- .4 x 10/sup 8/ M/sup -1/ sec/sup -1/.

  16. Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study

    Directory of Open Access Journals (Sweden)

    Michael W. Downey

    2016-01-01

    Full Text Available The traditional stainless steel wire tension band (WTB has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing. The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

  17. Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study.

    Science.gov (United States)

    Downey, Michael W; Duncan, Kyle; Kosmopoulos, Victor; Motley, Travis A; Carpenter, Brian B; Ogunyankin, Fadeke; Garrett, Alan

    2016-01-01

    The traditional stainless steel wire tension band (WTB) has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB) technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing). The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

  18. Attribution of the absorption bands of ruthenium-doped yttrium gallium garnet crystals to Ru 3+, Ru 4+, and Ru 5+ 4d-ions by MCD

    Science.gov (United States)

    Briat, B.; Ramaz, F.; Rjeily, H. Bou; Hodges, J. A.

    2005-01-01

    Ruthenium-doped yttrium gallium garnet single crystals were grown from a PbO/PbF 2/B 2O 3 flux. Most samples are blue, occasionally green, orange or lemon yellow, depending upon the growth temperature and the amount of a divalent or tetravalent counterion. A spectroscopic study was carried out using several complementary techniques (optical absorption, MCD, and EPR). Low temperature MCD enabled discrimination among those absorption bands correlated to paramagnetic ions (Ru 3+ or Ru 5+) or diamagnetic Ru 4+ at the octahedral site. Ru 3+ dominates in the lemon yellow sample with a nominal Ge/Ru ratio of ≈7, whereas Ru 5+ is responsible for the orange colour in a crystal with Ca/Ru ≈7. The strongest MCD features above 2.2 eV could be rationalised in terms of oxygen-to-Ru n+ ( n = 3-5) charge transfer transitions in octahedral complexes, whereas the 2 eV band of blue crystals is tentatively assigned to an intervalence transition implying Ru 4+. It is suggested that YIG films co-doped with ruthenium and a large amount of calcium or germanium might present interesting Faraday effect properties.

  19. Development of non-metallic and conformal dual band meta-skin and its absorption study for microwave applications

    Science.gov (United States)

    Borah, Dipangkar; Bhattacharyya, Nidhi S.

    2017-08-01

    An efficient approach for achieving a dual, conformal and non-metallic metamaterial absorber for microwave applications is proposed in this paper. The unit cell structures are simple circular ring resonators, made up of non-metallic and conducting expanded graphite, fabricated on a linear low density polyethylene substrate. The expanded graphite is synthesized, characterized and processed to be used as a conducting layer. The materials properties of linear low density polyethylene is investigated and found to be a promising candidate for flexible microwave applications. The developed absorber showed more than 90% absorption at 7.72 GHz and 9.92 GHz. Electric and magnetic fields are also simulated at the resonating frequency to understand the absorption mechanism. The proposed expanded graphite based metamaterial absorber possesses the advantages of being ultra-thin, flexible and non-corrosive.

  20. Endoscopic Sleeve Gastroplasty, Laparoscopic Sleeve Gastrectomy, and Laparoscopic Band for Weight Loss: How Do They Compare?

    Science.gov (United States)

    Novikov, Aleksey A; Afaneh, Cheguevara; Saumoy, Monica; Parra, Viviana; Shukla, Alpana; Dakin, Gregory F; Pomp, Alfons; Dawod, Enad; Shah, Shawn; Aronne, Louis J; Sharaiha, Reem Z

    2018-02-01

    Endoscopic sleeve gastroplasty (ESG) is a novel endobariatric procedure. Initial studies demonstrated an association of ESG with weight loss and improvement of obesity-related comorbidities. Our aim was to compare ESG to laparoscopic sleeve gastrectomy (LSG) and laparoscopic adjustable gastric banding (LAGB). We included 278 obese (BMI > 30) patients who underwent ESG (n = 91), LSG (n = 120), or LAGB (n = 67) at our tertiary care academic center. Primary outcome was percent total body weight loss (%TBWL) at 3, 6, 9, and 12 months. Secondary outcome measures included adverse events (AE), length of stay (LOS), and readmission rate. At 12-month follow-up, LSG achieved the greatest %TBWL compared to LAGB and ESG (29.28 vs 13.30 vs 17.57%, respectively; p ESG had a significantly lower rate of morbidity when compared to LSG or LAGB (p = 0.01). The LOS was significantly less for ESG compared to LSG or LAGB (0.34 ± 0.73 vs 3.09 ± 1.47 vs 1.66 ± 3.07 days, respectively; p ESG is a safe and feasible endobariatric option associated with low morbidity and short LOS in select patients.

  1. Variation of Routine Soil Analysis When Compared with Hyperspectral Narrow Band Sensing Method

    Directory of Open Access Journals (Sweden)

    José A. M. Demattê

    2010-08-01

    Full Text Available The objectives of this research were to: (i develop hyperspectral narrow-band models to determine soil variables such as organic matter content (OM, sum of cations (SC = Ca + Mg + K, aluminum saturation (m%, cations saturation (V%, cations exchangeable capacity (CEC, silt, sand and clay content using visible-near infrared (Vis-NIR diffuse reflectance spectra; (ii compare the variations of the chemical and the spectroradiometric soil analysis (Vis-NIR. The study area is located in São Paulo State, Brazil. The soils were sampled over an area of 473 ha divided into grids (100 × 100 m with a total of 948 soil samples georeferenced. The laboratory RS data were obtained using an IRIS (Infrared Intelligent Spectroradiometer sensor (400–2,500 nm with a 2-nm spectral resolution between 450 and 1,000 nm and 4-nm between 1,000 and 2,500 nm. Satellite reflectance values were sampled from corrected Landsat Thematic Mapper (TM images. Each pixel in the image was evaluated as its vegetation index, color compositions and soil line concepts regarding certain locations of the field in the image. Chemical and physical analysis (organic matter content, sand, silt, clay, sum of cations, cations saturation, aluminum saturation and cations exchange capacity were performed in the laboratory. Statistical analysis and multiple regression equations for soil attribute predictions using radiometric data were developed. Laboratory data used 22 bands and 13 “Reflectance Inflexion Differences, RID” from different wavelength intervals of the optical spectrum. However, for TM-Landsat six bands were used in analysis (1, 2, 3, 4, 5, and 7.Estimations of some tropical soil attributes were possible using laboratory spectral analysis. Laboratory spectral reflectance (SR presented high correlations with traditional laboratory analyses for the soil attributes such as clay (R2 = 0.84, RMSE = 3.75 and sand (R2 = 0.85, RMSE = 3.74. The most sensitive narrow-bands in modeling

  2. Cirrus Cloud Optical and Microphysical Property Retrievals from eMAS During SEAC4RS Using Bi-Spectral Reflectance Measurements Within the 1.88 micron Water Vapor Absorption Band

    Science.gov (United States)

    Meyer, K.; Platnick, S.; Arnold, G. T.; Holz, R. E.; Veglio, P.; Yorks, J.; Wang, C.

    2016-01-01

    Previous bi-spectral imager retrievals of cloud optical thickness (COT) and effective particle radius (CER) based on the Nakajima and King (1990) approach, such as those of the operational MODIS cloud optical property retrieval product (MOD06), have typically paired a non-absorbing visible or near-infrared wavelength, sensitive to COT, with an absorbing shortwave or midwave infrared wavelength sensitive to CER. However, in practice it is only necessary to select two spectral channels that exhibit a strong contrast in cloud particle absorption. Here it is shown, using eMAS observations obtained during NASAs SEAC4RS field campaign, that selecting two absorbing wavelength channels within the broader 1.88 micron water vapor absorption band, namely the 1.83 and 1.93 micron channels that have sufficient differences in ice crystal single scattering albedo, can yield COT and CER retrievals for thin to moderately thick single-layer cirrus that are reasonably consistent with other solar and IR imager-based and lidar-based retrievals. A distinct advantage of this channel selection for cirrus cloud retrievals is that the below cloud water vapor absorption minimizes the surface contribution to measured cloudy TOA reflectance, in particular compared to the solar window channels used in heritage retrievals such as MOD06. This reduces retrieval uncertainty resulting from errors in the surface reflectance assumption, as well as reduces the frequency of retrieval failures for thin cirrus clouds.

  3. Aerosolized liposomes with dipalmitoyl phosphatidylcholine enhance pulmonary absorption of encapsulated insulin compared with co-administered insulin.

    Science.gov (United States)

    Chono, Sumio; Togami, Kohei; Itagaki, Shirou

    2017-11-01

    We have previously shown that aerosolized liposomes with dipalmitoyl phosphatidylcholine (DPPC) enhance the pulmonary absorption of encapsulated insulin. In this study, we aimed to compare insulin encapsulated into the liposomes versus co-administration of empty liposomes and unencapsulated free insulin, where the DPCC liposomes would serve as absorption enhancer. The present study provides the useful information for development of noninvasive treatment of diabetes. Co-administration of empty DPPC liposomes and unencapsulated free insulin was investigated in vivo to assess the potential enhancement in protein pulmonary absorption. Co-administration was compared to DPPC liposomes encapsulating insulin, and free insulin. DPPC liposomes enhanced the pulmonary absorption of unencapsulated free insulin; however, the enhancing effect was lower than that of the DPPC liposomes encapsulating insulin. The mechanism of the pulmonary absorption of unencapsulated free insulin by DPPC liposomes involved the opening of epithelial cell space in alveolar mucosa, and not mucosal cell damage, similar to that of the DPPC liposomes encapsulating insulin. In an in vitro stability test, insulin in the alveolar mucus layer that covers epithelial cells was stable. These findings suggest that, although unencapsulated free insulin spreads throughout the alveolar mucus layer, the concentration of insulin released near the absorption surface is increased by the encapsulation of insulin into DPPC liposomes and the absorption efficiency is also increased. We revealed that the encapsulation of insulin into DPPC liposomes is more effective for pulmonary insulin absorption than co-administration of DPPC liposomes and unencapsulated free insulin.

  4. Comparative study of absorption in tilted silicon nanowire arrays for photovoltaics.

    Science.gov (United States)

    Kayes, Md Imrul; Leu, Paul W

    2014-01-01

    Silicon nanowire arrays have been shown to demonstrate light trapping properties and promising potential for next-generation photovoltaics. In this paper, we show that the absorption enhancement in vertical nanowire arrays on a perfectly electric conductor can be further improved through tilting. Vertical nanowire arrays have a 66.2% improvement in ultimate efficiency over an ideal double-pass thin film of the equivalent amount of material. Tilted nanowire arrays, with the same amount of material, exhibit improved performance over vertical nanowire arrays across a broad range of tilt angles (from 38° to 72°). The optimum tilt of 53° has an improvement of 8.6% over that of vertical nanowire arrays and 80.4% over that of the ideal double-pass thin film. Tilted nanowire arrays exhibit improved absorption over the solar spectrum compared with vertical nanowires since the tilt allows for the excitation of additional modes besides the HE 1m modes that are excited at normal incidence. We also observed that tilted nanowire arrays have improved performance over vertical nanowire arrays for a large range of incidence angles (under about 60°).

  5. Microwave processed bulk and nano NiMg ferrites: A comparative study on X-band electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Chandra Babu Naidu, K., E-mail: chandrababu954@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); Madhuri, W., E-mail: madhuriw12@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); IFW, Leibniz Institute for Solid State and Materials Research, Technische Universität Dresden, 01069 Dresden (Germany)

    2017-02-01

    Bulk and nano Ni{sub 1-x}Mg{sub x}Fe{sub 2}O{sub 4} (x = 0–1) samples were synthesized via microwave double sintering and microwave assisted hydrothermal techniques respectively. The diffraction pattern confirmed the formation of cubic spinel phases in case of both the ferrites. The larger bulk densities were achieved to the bulk than that of nano. In addition, a comparative study on X-band (8.4–12 GHz) electromagnetic interference shielding properties of current bulk and nanomaterials was elucidated. The results showed that the bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} composition revealed the highest total shielding efficiency (SE{sub T}) of ∼17 dB. In comparison, the shielding efficiency values of all bulk contents were higher than that of nano because of larger bulk densities. Moreover, the ac-electromagnetic parameters such as electrical conductivity (σ{sub ac}), the respective real (ε′ & μ′) and imaginary parts (ε″ & μ″) of complex permittivity and permeability were investigated as a function of gigahertz frequency. The bulk ferrites of x = 0.4 & 0.6 showed the high ε″ of 10.26 & 6.71 and μ″ of 3.65 & 3.09 respectively at 12 GHz which can work as promising microwave absorber materials. Interestingly, nanoferrites exhibited negative μ″ values at few frequencies due to geometrical effects which improves the microwave absorption. - Highlights: • Bulk and nano NiMg ferrites are prepared by microwave and hydrothermal method. • X-band EMI shielding properties are studied for both bulk and nano ferrites. • Bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} revealed the highest SE{sub T} of ∼17 dB at 8.4 GHz. • Bulk x = 0.4 & 0.6 showed the high ε″ and μ″ at 12 GHz for absorber applications.

  6. Effective dielectric function of TiO2 nanoparticles under laser pumping in the fundamental absorption band

    Science.gov (United States)

    Zimnyakov, D. A.; Yuvchenko, S. A.

    2017-06-01

    A nonlinear optical response of TiO2 nanoparticles under pumping by 355-nm laser radiation is experimentally investigated. Using the data obtained by z-scanning with simultaneous measurement of the scattering intensity, the effective permittivity of particles is reconstructed as a function of the pump intensity. It is found that graphical mapping of the relationship between the real and imaginary parts of the permittivity can be obtained using an affine transformation of a similar map of the frequency-dependent dielectric function for the Lorentz model. It is shown that an increase in the pump intensity should lead to a red shift of the absorption maximum of nanoparticles and a rise in the plasma frequency, which is estimated (using a single-oscillator Lorenz model) from the obtained values of the real and imaginary parts of the effective permittivity for the probe radiation wavelength in use.

  7. [Comparative study on absorption kinetics in intestines of rats of epimedii foliunm of Xianlinggubao capsules prepared by different processes].

    Science.gov (United States)

    Wu, Huichao; Lu, Yang; Du, Shouying; Chen, Wen; Wang, Yue

    2011-10-01

    To study the characteristics of intestinal absorption of icariin and epimedin C of Xianlinggubao capsules, and compare the absorption of Xianlinggubao capsules prepared by different processes. Non everted gut sac method was applied to investigate the influence of absorption sites and concentration on icariin and epimedin C, which were determined by HPLC. The absorption rate constants of epimedin C in duodenum were absolutely more than that in jejunum and ileum (P absorption rate constants of icariin in jejunum were absolutely less than that in duodenum and ileum (P absorption rate constants of epimedin C and icariin kept at the same level when the concentrations of drug solution were at high, middle and low level. The Ka of epimedin C at three levels were 0.040, 0.058, 0.061 h(-1) , respectively, and the Ka of icariin at three levels were 0.002, 0.007, 0.003 h(-1), respectively. Intestinal absorption of icariin and epimedin C is not effected by concentrations. The absorption rate constants of icariin and epimedin C in new Xianlinggubao capsules are higher.

  8. Microwave absorption in X and Ku band frequency of cotton fabric coated with Ni-Zn ferrite and carbon formulation in polyurethane matrix

    Science.gov (United States)

    Gupta, K. K.; Abbas, S. M.; Goswami, T. H.; Abhyankar, A. C.

    2014-08-01

    The present study highlights various microwave properties, i.e. reflection, transmission, absorption and reflection loss, of the coated cotton fabric [formulation: Ni-Zn ferrite (Ni 0.5Zn0.5Fe2O4) and carbon black (acetylene black) at concentrations of 30, 40, 50, 60 and70 g of ferrite and 5 g carbon in each 100 ml polyurethane] evaluated at 8-18 GHz frequency. The uniform density of filling materials in coated fabrics (dotted marks in SEM micrograph) indicates homogeneous dispersion of conducting fillers in polyurethane and the density of filling material cluster increases with increase in ferrite concentration. SEM images also show uniform coating of conducting fillers/resin system over individual fibers and interweave spaces. The important parameters governing the microwave properties of coated fabrics i.e. permittivity and permeability, S-parameters, reflection loss, etc. were studied in a HVS free space microwave measurement system. The lossy character of coated fabric is found to increase with increase of ferrite content; the ferrite content decreases the impedance and increases the permittivity and permeability values. The 1.6-1.8 mm thick coated fabric sample (40 wt% ferrite, 3 wt% carbon and 57 wt% PU) has shown about 40% absorption, 20% transmission and 40% reflectance in X (8.2-12.4 GHz) and Ku (12-18 GHz) frequency bands. The reflection loss at 13.5 GHz has shown the highest peak value (22.5 dB) due to coated sample optical thickness equal to λ/4 and more than 7.5 dB in entire Ku band. Owing to its thin and flexible nature, the coated fabric can be used as apparel in protecting human being from hazardous microwaves and also as radar camouflage covering screen in defense.

  9. Highly ordered monolayer/bilayer TiO2 hollow sphere films with widely tunable visible-light reflection and absorption bands.

    Science.gov (United States)

    Li, Jie; Qin, Yao; Jin, Chao; Li, Ying; Shi, Donglu; Schmidt-Mende, Lukas; Gan, Lihua; Yang, Jinhu

    2013-06-07

    Monolayer and bilayer TiO2 hollow hemisphere/sphere (THH/THS) films consisting of highly ordered hexagonal-patterned THHs/THSs with thin shells of ~10 nm and different diameters of ~170 and ~470 nm have been prepared by templating of two-dimensional polystyrene sphere (PS) assembly films coupled with TiO2 sputtering/wet coating approaches. Owing to their precisely adjustable structural parameters, such as THH/THS shape and diameter as well as film layer thickness, the prepared THH/THS films exhibit widely tunable visible-light reflection and absorption bands, i.e. from 380 to 850 nm for reflection and 390 to 520 nm for absorption, respectively. The mechanism of the novel optical behaviors of the THH/THS films has been discussed in depth, combined with some calculations according to Bragg's law. In addition, photocatalytic experiments of RhB degradation employing the THH/THS films as recyclable catalysts have been conducted. The THH/THS films with controlled structures and precisely tunable optical properties are attractive for a wide range of applications, such as recyclable catalysts for photocatalysis, efficient oxide electrodes or scattering layers for solar cells, gas-permeable electrode materials for high-performance sensors and so on.

  10. The human iliotibial band is specialized for elastic energy storage compared with the chimp fascia lata.

    Science.gov (United States)

    Eng, Carolyn M; Arnold, Allison S; Biewener, Andrew A; Lieberman, Daniel E

    2015-08-01

    This study examines whether the human iliotibial band (ITB) is specialized for elastic energy storage relative to the chimpanzee fascia lata (FL). To quantify the energy storage potential of these structures, we created computer models of human and chimpanzee lower limbs based on detailed anatomical dissections. We characterized the geometry and force-length properties of the FL, tensor fascia lata (TFL) and gluteus maximus (GMax) in four chimpanzee cadavers based on measurements of muscle architecture and moment arms about the hip and knee. We used the chimp model to estimate the forces and corresponding strains in the chimp FL during bipedal walking, and compared these data with analogous estimates from a model of the human ITB, accounting for differences in body mass and lower extremity posture. We estimate that the human ITB stores 15- to 20-times more elastic energy per unit body mass and stride than the chimp FL during bipedal walking. Because chimps walk with persistent hip flexion, the TFL and portions of GMax that insert on the FL undergo smaller excursions (origin to insertion) than muscles that insert on the human ITB. Also, because a smaller fraction of GMax inserts on the chimp FL than on the human ITB, and thus its mass-normalized physiological cross-sectional area is about three times less in chimps, the chimp FL probably transmits smaller muscle forces. These data provide new evidence that the human ITB is anatomically derived compared with the chimp FL and potentially contributes to locomotor economy during bipedal locomotion. © 2015. Published by The Company of Biologists Ltd.

  11. A Comparative Study of the Effects of Substrate Composite Materials on External and Internal Handset Antenna EM Absorption

    Directory of Open Access Journals (Sweden)

    Md Ikbal HOSSAIN

    2016-09-01

    Full Text Available Cellular phones are used in the vicinity of a human head, which absorbs power from antenna radiation. This investigation analyzes the effects of antenna substrate materials on electromagnetic (EM absorption in a human head. Antennas are used in analysis with four different dielectric substrate materials, which are Bakelite, FR4 glass epoxy, Rogers R04003, and Taconic TLC. Moreover, two different thicknesses of each substrate are considered in the experimental setup. The EM absorption associated with two types of cell phone antennas is evaluated in the closed vicinity of the human head model. One of them is planar inverted-F antenna (PIFA, which is used as the internal handset antenna and another one is helical antenna, which is used as external handset antenna. This investigation consists of two different operating frequency bands, GSM 900 MHz and DCS 1800 MHz. The EM absorption in the human head is presented using the peak specific absorption rate (SAR and total absorbed power (TAP by the user. The finite-difference time-domain (FDTD method based on Computer Simulation Technology (CST Microwave studio is utilized in this investigation. The obtained results show that the substrate materials do not effect SAR and TAP values considerably for both antennas, but substrate thickness affects the SAR and TAP values significantly. In addition, the substrate thickness affects the SAR and TAP values significantly in most of the cases Moreover, PIFA produces lower SAR than that of a helical antenna significantly for both GSM and DCS frequency band.DOI: http://dx.doi.org/10.5755/j01.ms.22.3.8889

  12. A comparative study of absorption in vertically and laterally oriented InP core-shell nanowire photovoltaic devices.

    Science.gov (United States)

    Nowzari, Ali; Heurlin, Magnus; Jain, Vishal; Storm, Kristian; Hosseinnia, Ali; Anttu, Nicklas; Borgström, Magnus T; Pettersson, Håkan; Samuelson, Lars

    2015-03-11

    We have compared the absorption in InP core-shell nanowire p-i-n junctions in lateral and vertical orientation. Arrays of vertical core-shell nanowires with 400 nm pitch and 280 nm diameter, as well as corresponding lateral single core-shell nanowires, were configured as photovoltaic devices. The photovoltaic characteristics of the samples, measured under 1 sun illumination, showed a higher absorption in lateral single nanowires compared to that in individual vertical nanowires, arranged in arrays with 400 nm pitch. Electromagnetic modeling of the structures confirmed the experimental observations and showed that the absorption in a vertical nanowire in an array depends strongly on the array pitch. The modeling demonstrated that, depending on the array pitch, absorption in a vertical nanowire can be lower or higher than that in a lateral nanowire with equal absorption predicted at a pitch of 510 nm for our nanowire geometry. The technology described in this Letter facilitates quantitative comparison of absorption in laterally and vertically oriented core-shell nanowire p-i-n junctions and can aid in the design, optimization, and performance evaluation of nanowire-based core-shell photovoltaic devices.

  13. Comparable reduction in cholesterol absorption after two different ways of phytosterol administration in humans.

    Science.gov (United States)

    Amiot, Marie Josèphe; Knol, Diny; Cardinault, Nicolas; Nowicki, Marion; Bott, Romain; Antona, Claudine; Borel, Patrick; Bernard, Jean-Paul; Duchateau, Guus; Lairon, Denis

    2013-04-01

    Consumption of phytosterols is a nutritional strategy to reduce cholesterol absorption, but the efficacy of various phytosterol intake modalities remains uncertain. The main objective was to investigate the effects of phytosterol esters (PE) provided either as a spread (dispersed in fat) during a mixed meal or as a minidrink (micro-dispersed in liquid form) after a meal. In a randomized, single-blinded crossover design, 12 healthy intubated volunteers tested three different liquid meal sequences with and without PE. The liquid meal (500 mL, Fortisip) contained an oral dose (80 mg) of deuterium-enriched cholesterol (D7C). The intubation was stopped at 240 min, and the fate of sterols was determined in the different phases of duodenal content samples as function of time. A second solid fat-containing meal without sterols was consumed at 270 min. D7C was quantified in chylomicrons and plasma for 8 h. The conditions tested were as follows: (1) no PE added (control), (2) PE in a spread added into a liquid meal (PE-spread meal) and (3) PE given 30 min after a liquid meal as 100-g yoghurt drink (PE-minidrink meal). Addition of PE decreased the incorporation of cholesterol into the duodenum aqueous phase including micelles. PE added as a spread or as a minidrink significantly and comparably lowered meal cholesterol occurrence in chylomicrons (-40 % for PE-spread and -54 % for PE-minidrink, p < 0.0001) compared with the control meal. PE either dispersed in fat during a meal or micro-dispersed in a liquid form after a meal resulted in a markedly reduced occurrence of meal-derived cholesterol in the circulation at a comparable extent.

  14. THE COST OF PRODUCTION UNDER DIRECT COSTING AND ABSORPTION COSTING – A COMPARATIVE APPROACH

    Directory of Open Access Journals (Sweden)

    Bunea-Bontaş Cristina Aurora

    2013-04-01

    Full Text Available Managerial accounting has an important role in strategic management of a company, being designed especially for managers, in order to optimise their decision regarding operating activities. One of the objectives of managerial accounting is the cost calculation, for measuring inventory costs, and the costs and profitability of products and services. Cost calculation systems can vary in terms of which costs are assigned to cost objects, two significant calculation systems being adopted by the costing theory: full cost accounting, which includes all costs of production as product costs, and partial cost accounting, which includes only those costs that vary with output. This article provides a comparative approach regarding the differences between the calculation of the cost of production under direct costing and absorption costing. It also examines the implication of using each of these calculation systems on the financial position and financial performance of the companies reported on the statement of financial position and the income statement. Finally, the advantages of using direct costing for internal reporting are discussed, considering that this method is not acceptable for external reporting to stockholders and other external users.

  15. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners

    International Nuclear Information System (INIS)

    Riffat, S.B.; Qiu Guoquan

    2004-01-01

    This paper compares the performance of three types of domestic air-conditioners, namely the vapour compression air-conditioner (VCAC), the absorption air-conditioner (AAC) and the thermoelectric air-conditioner (TEAC). The basic cycles of the three types of air-conditioning systems are described and methods to calculate their coefficients of performance are presented. General specification data for each type of air-conditioner are given, and performance characteristics are presented. The comparison shows that although VCACs have the advantages of high COP and low purchase price, use of these systems will be phased out due to their contribution to the greenhouse effect and depletion of the ozone layer. AACs are generally bulky, complex and expensive but operate on thermal energy, so their operational consumption is low. TEACs are environmental friendly, simple and reliable but still very expensive at present. Their low COP is an additional factor limiting their application for domestic cooling. TEACs however, have a large potential market as air-conditioners for small enclosures, such as cars and submarine cabins, where the power consumption would be low, or safety and reliability would be important

  16. Comparative Study of Heavy Metals in Dried and Fluid Milk in Peshawar by Atomic Absorption Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Ghosia Lutfullah

    2014-01-01

    Full Text Available Various essential and toxic heavy metals (Ca, Mg, Cu, Zn, Fe, Mn, Pb, Cd, Cr, and Ni contents in various types of dried (infant formula and powdered and fluid (fresh and processed cow milk were assessed by atomic absorption spectrophotometry. The milk samples were collected from local markets of different parts of Peshawar city, Pakistan. Heavy metal concentrations varied significantly depending upon the type of milk. The heavy metal concentrations in most of the samples were within normal and permissible ranges. It was observed that the samples contained considerable amounts of calcium, while magnesium levels were well above the required levels. The results also revealed that copper levels were slightly lower than the permissible limits. The concentration of zinc in dried milk samples was greater than the values for the liquid milk types. Infant milk formulae had higher iron levels as compared to other milk samples because of the added constituents. Significant differences were observed in the mean values of manganese and cadmium in different types of milk. The toxic metals were within the acceptable limits and did not show significant levels leading to toxicity.

  17. Comparing auditory brainstem responses (ABRs) to toneburst and narrow band CE-chirp in young infants.

    Science.gov (United States)

    Rodrigues, Gabriela Ribeiro Ivo; Ramos, Natália; Lewis, Doris Ruthi

    2013-09-01

    The difference of characteristics (latency and amplitude) between toneburst and narrow CE-chirp stimuli on ABR recording was analyzed in normal hearing infants. 500, 1000, 2000 and 4000 Hz toneburst and narrow band CE-chirp auditory brainstem responses (ABRs) were recorded in 40 normal-hearing infants. The amplitude and latency parameters of the ABR were collected for each of the four stimulus levels: 80, 60, 40, and 20 dB nHL. Both stimuli started from 80 dB nHL using alternating polarity and the rates were both 27.1/s. The toneburst latencies are greater than narrow band CE-chirp latencies for all intensities at 500, 1000 and 2000 Hz (p Hz this difference was not significant. At 500 Hz, wave V amplitude is larger for toneburst than narrow CE-chirp (p Hz there is no difference between the wave V toneburst and narrow band CE-chirp amplitudes at 80 dB nHL (p = 0.940; p = 0.776 and p = 0.217 respectively). On the other hand, in the levels to 60, 40 and 20 dB nHL, narrow band CE-chirp amplitudes are larger than toneburst amplitude (p < 0.001). Narrow band CE-chirp ABRs generates shorter latencies than the toneburst ABRs, especially to low frequencies. Higher amplitudes were found with narrow band CE-chirp stimuli for all frequencies tested, except to high levels. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Endoscopic band ligation could decrease recurrent bleeding in Mallory-Weiss syndrome as compared to haemostasis by hemoclips plus epinephrine.

    Science.gov (United States)

    Lecleire, S; Antonietti, M; Iwanicki-Caron, I; Duclos, A; Ramirez, S; Ben-Soussan, E; Hervé, S; Ducrotté, P

    2009-08-15

    Mallory-Weiss syndrome (MWS) with active bleeding at endoscopy may require endoscopic haemostasis the modalities of which are not well-defined. To compare the efficacy of endoscopic band ligation vs. hemoclip plus epinephrine (adrenaline) in bleeding MWS. From 2001 to 2008, 218 consecutive patients with a MWS at endoscopy were hospitalized in our Gastrointestinal Bleeding Unit. In 56 patients (26%), an endoscopic haemostasis was required because of active bleeding. Band ligation was performed in 29 patients (Banding group), while hemoclip application plus epinephrine injection was performed in 27 patients (H&E group). Treatment efficacy and early recurrent bleeding were retrospectively compared between the two groups. Primary endoscopic haemostasis was achieved in all patients. Recurrent bleeding occurred in 0% in Banding group vs. 18% in H&E group (P = 0.02). The use of hemoclips plus epinephrine (OR = 3; 95% CI = 1.15-15.8) and active bleeding at endoscopy (OR = 1.9; 95% CI = 1.04-5.2) were independent predictive factors of early recurrent bleeding. Haemostasis by hemoclips plus epinephrine was an independent predictive factor of rebleeding. This result suggests that band ligation could be the first choice endoscopic treatment for bleeding MWS, but requires further prospective assessment.

  19. Highly ordered monolayer/bilayer TiO2 hollow sphere films with widely tunable visible-light reflection and absorption bands

    Science.gov (United States)

    Li, Jie; Qin, Yao; Jin, Chao; Li, Ying; Shi, Donglu; Schmidt-Mende, Lukas; Gan, Lihua; Yang, Jinhu

    2013-05-01

    Monolayer and bilayer TiO2 hollow hemisphere/sphere (THH/THS) films consisting of highly ordered hexagonal-patterned THHs/THSs with thin shells of ~10 nm and different diameters of ~170 and ~470 nm have been prepared by templating of two-dimensional polystyrene sphere (PS) assembly films coupled with TiO2 sputtering/wet coating approaches. Owing to their precisely adjustable structural parameters, such as THH/THS shape and diameter as well as film layer thickness, the prepared THH/THS films exhibit widely tunable visible-light reflection and absorption bands, i.e. from 380 to 850 nm for reflection and 390 to 520 nm for absorption, respectively. The mechanism of the novel optical behaviors of the THH/THS films has been discussed in depth, combined with some calculations according to Bragg's law. In addition, photocatalytic experiments of RhB degradation employing the THH/THS films as recyclable catalysts have been conducted. The THH/THS films with controlled structures and precisely tunable optical properties are attractive for a wide range of applications, such as recyclable catalysts for photocatalysis, efficient oxide electrodes or scattering layers for solar cells, gas-permeable electrode materials for high-performance sensors and so on.Monolayer and bilayer TiO2 hollow hemisphere/sphere (THH/THS) films consisting of highly ordered hexagonal-patterned THHs/THSs with thin shells of ~10 nm and different diameters of ~170 and ~470 nm have been prepared by templating of two-dimensional polystyrene sphere (PS) assembly films coupled with TiO2 sputtering/wet coating approaches. Owing to their precisely adjustable structural parameters, such as THH/THS shape and diameter as well as film layer thickness, the prepared THH/THS films exhibit widely tunable visible-light reflection and absorption bands, i.e. from 380 to 850 nm for reflection and 390 to 520 nm for absorption, respectively. The mechanism of the novel optical behaviors of the THH/THS films has been discussed

  20. Karyotypic evolution in family Hipposideridae (Chiroptera, Mammalia) revealed by comparative chromosome painting, G- and C-banding.

    Science.gov (United States)

    Mao, Xiu-Guang; Wang, Jin-Huan; Su, Wei-Ting; Wang, Ying-Xiang; Yang, Feng-Tang; Nie, Wen-Hui

    2010-10-01

    Comparing to its sister-family (Rhinolophidae), Hipposideridae was less studied by cytogenetic approaches. Only a few high-resolution G-banded karyotypes have been reported so far, and most of the conclusions on the karyotypic evolution in Hipposideridae were based on conventional Giemsa-staining. In this study, we applied comparative chromosome painting, a method of choice for genome-wide comparison at the molecular level, and G- and C-banding to establish comparative map between five hipposiderid species from China, using a whole set of chromosome-specific painting probes from one of them (Aselliscus stoliczkanus). G-band and C-band comparisons between homologous segments defined by chromosome painting revealed that Robertsonian translocations, paracentric inversions and heterochromatin addition could be the main mechanism of chromosome evolution in Hipposideridae. Comparative analysis of the conserved chromosomal segments among five hipposiderid species and outgroup species suggests that bi-armed chromosomes should be included into the ancestral karyotype of Hipposideridae, which was previously believed to be exclusively composed of acrocentric chromosomes.

  1. Cardiovascular safety of the oral controlled absorption system (OCAS) formulation of tamsulosin compared to the modified release (MR) formulation

    NARCIS (Netherlands)

    Michel, M. C.; Korstanje, C.; Klauwinkel, W.; Shear, M.; Davies, J.; Quartel, A.

    2005-01-01

    Objective: The potential to interfere with efferent adrenergic drive in the cardiovascular system was tested in elderly healthy subjects for the new oral controlled absorption system (OCAS) 0.4 mg tablet formulation of tamsulosin compared to the modified release (MR) 0.4 mg capsule formulation of

  2. In vivo percutaneous absorption of boric acid, borax, and disodium octaborate tetrahydrate in humans compared to in vitro absorption in human skin from infinite and finite doses.

    Science.gov (United States)

    Wester, R C; Hui, X; Hartway, T; Maibach, H I; Bell, K; Schell, M J; Northington, D J; Strong, P; Culver, B D

    1998-09-01

    Literature from the first half of this century report concern for toxicity from topical use of boric acid, but assessment of percutaneous absorption has been impaired by lack of analytical sensitivity. Analytical methods in this study included inductively coupled plasma-mass spectrometry which now allows quantitation of percutaneous absorption of 10B in 10B-enriched boric acid, borax, and disodium octaborate tetrahydrate (DOT) in biological matrices. This made it possible, in the presence of comparatively large natural dietary boron intakes for the in vivo segment of this study, to quantify the boron passing through skin. Human volunteers were dosed with 10B-enriched boric acid, 5.0%, borax, 5.0%, or disodium octaborate tetrahydrate, 10%, in aqueous solutions. Urinalysis, for boron and changes in boron isotope ratios, was used to measure absorption. Boric acid in vivo percutaneous absorption was 0.226 (SD = 0.125) mean percentage dose, with flux and permeability constant (Kp) calculated at 0.009 microgram/cm2/h and 1.9 x 10(-7) cm/h, respectively. Borax absorption was 0.210 (SD = 0.194) mean percentage of dose, with flux and Kp calculated at 0.009 microgram/cm2/h and 1.8 x 10(-7) cm/h, respectively. DOT absorption was 0.122 (SD = 0.108) mean percentage, with flux and Kp calculated at 0.01 microgram/cm2/h and 1.0 x 10(-7) cm/h, respectively. Pretreatment with the potential skin irritant 2% sodium lauryl sulfate had no effect on boron skin absorption. In vitro human skin percentage of doses of boric acid absorbed were 1.2 for a 0.05% solution, 0.28 for a 0.5% solution, and 0.70 for a 5.0% solution. These absorption amounts translated into flux values of, respectively, 0.25, 0.58, and 14.58 micrograms/cm2/h and permeability constants (Kp) of 5.0 x 10(-4), 1.2 x 10(-4), and 2.9 x 10(-4) cm/h for the 0.05, 0.5, and 5.0% solutions. The above in vitro doses were at infinite, 1000 microliters/cm2 volume. At 2 microliters/cm2 (the in vivo dosing volume), flux decreased some

  3. A comparative study in fixation methods of medial malleolus fractures between tension bands wiring and screw fixation.

    Science.gov (United States)

    Mohammed, Ayyoub A; Abbas, Khalid Ahmed; Mawlood, Ammar Salah

    2016-01-01

    The aim of this study is to compare two methods of internal fixations of fractured medial malleolus which are simple screw fixation and tension band wiring. Over 5 years we grouped 20 patients with fractured medial malleolus into two groups of operative treatments, group1 treated by malleolar screw fixation and group2 by tension band wiring. The patients were with same age group, gender, fracture type, and etiology. We use statistical analysis for make a comparative study between the two ways of surgical treatment. The mean time for radiologic bone union was 11.8 weeks in group1 patients and 9.4 weeks in group2 patients (P = 0.03). No patients had any sign of fixation failure or Kirschner wires migration. According to the modified ankle scoring system of Olerud and Molander, excellent and good results were achieved in 80 % in group1 patients and 90 % in group2 patients (P = 0.049). Tension-band wiring may be better treatment option for internal fixation of medial malleolar fractures than screw fixation. From these findings we recommend a further randomized clinical trial of larger number of cases and longer follow-up duration in order to regard tension-band wiring a better operative option for fixation of medial malleolar fractures.

  4. Follow-up of treated coeliac patients: Sugar absorption test and intestinal biopsies compared

    NARCIS (Netherlands)

    Uil, J. J.; van Elburg, R. M.; van Overbeek, F. M.; Meyer, J. W.; Mulder, C. J.; Heymans, H. S.

    1996-01-01

    Objective: To determine whether the sugar absorption test (SAT) during follow-up of patients with coeliac disease on a gluten-free diet (GFD) correlates with improvement of the villous architecture of the small intestine. Methods: The SAT was performed in coeliacs at diagnosis and during follow-up

  5. The comparative absorption of silicon from different foods and food supplements

    Science.gov (United States)

    Sripanyakorn, Supannee; Jugdaohsingh, Ravin; Dissayabutr, Wacharee; Anderson, Simon H. C.; Thompson, Richard P. H.; Powell, Jonathan J.

    2009-01-01

    Dietary Si (orthosilicic acid; OSA) appears important in connective tissue health, and although the sources and intakes of Si are well established, its absorption is not. Si absorption was measured from eight high-Si-containing sources: alcohol-free beer; OSA solution (positive control); bananas; green beans; supplemental choline-stabilised OSA (ChOSA); supplemental monomethyl silanetriol (MMST); supplemental colloidal silica (CS); magnesium trisilicate British Pharmacopoeia antacid (MTBP). Two of the supplements and the antacid were pre-selected following an in vitro dissolution assay. Fasting, healthy subjects (CS, n 3; others, n ≥ 5) each ingested two of the sources separated by a 1-week wash-out period. Blood and urine were collected and measured for total Si concentrations by inductively coupled plasma optical emission spectrometry. Absorption, based on urinary Si excretion, was highest for MMST and alcohol-free beer (64 % of dose), followed by green beans (44 %), OSA (43 %), ChOSA (17 %), bananas and MTBP (4 %) and CS (1 %). Peak serum concentrations occurred by 0.5 h for MMST and green beans, 1.5 h for OSA and alcohol-free beer, 2 h for ChOSA and CS, and 4 h for MTBP. Area under the serum curves correlated positively with urinary Si output (r 0·82; P<0·0001). Absorption of Si from supplements and antacids was consistent with their known chemical speciation and kinetics of dissolution under simulated gastrointestinal conditions. Monomeric silicates were readily absorbed, while particulate silicates were decreasingly well absorbed with increasing polymerisation. The present results highlight the need to allow for relative absorption of Si from different foods or supplements in subsequent epidemiological and intervention studies. PMID:19356271

  6. Photodissociation dynamics in the first absorption band of pyrrole. I. Molecular Hamiltonian and the Herzberg-Teller absorption spectrum for the A12(π σ* ) ←X˜ 1 A1(π π ) transition

    Science.gov (United States)

    Picconi, David; Grebenshchikov, Sergy Yu.

    2018-03-01

    This paper opens a series in which the photochemistry of the two lowest πσ* states of pyrrole and their interaction with each other and with the ground electronic state X ˜ are studied using ab initio quantum mechanics. New 24-dimensional potential energy surfaces for the photodissociation of the N-H bond and the formation of the pyrrolyl radical are calculated using the multiconfigurational perturbation theory (CASPT2) for the electronic states X ˜ (π π ) , 11A2(πσ*), and 11B1(πσ*) and locally diabatized. In this paper, the ab initio calculations are described and the photodissociation in the state 11A2(πσ*) is analyzed. The excitation 11 A2←X ˜ is mediated by the coordinate dependent transition dipole moment functions constructed using the Herzberg-Teller expansion. Nuclear dynamics, including 6, 11, and 15 active degrees of freedom, are studied using the multi-configurational time-dependent Hartree method. The focus is on the frequency resolved absorption spectrum as well as on the dissociation time scales and the resonance lifetimes. Calculations are compared with available experimental data. An approximate convolution method is developed and validated, with which absorption spectra can be calculated and assigned in terms of vibrational quantum numbers. The method represents the total absorption spectrum as a convolution of the diffuse spectrum of the detaching H-atom and the Franck-Condon spectrum of the heteroaromatic ring. Convolution calculation requires a minimal quantum chemical input and is a promising tool for studying the πσ* photodissociation in model biochromophores.

  7. Can optical diagnosis of small colon polyps be accurate? Comparing standard scope without narrow banding to high definition scope with narrow banding.

    Science.gov (United States)

    Ashktorab, Hassan; Etaati, Firoozeh; Rezaeean, Farahnaz; Nouraie, Mehdi; Paydar, Mansour; Namin, Hassan Hassanzadeh; Sanderson, Andrew; Begum, Rehana; Alkhalloufi, Kawtar; Brim, Hassan; Laiyemo, Adeyinka O

    2016-07-28

    To study the accuracy of using high definition (HD) scope with narrow band imaging (NBI) vs standard white light colonoscope without NBI (ST), to predict the histology of the colon polyps, particularly those high definition colonoscopes with NBI. The histopathologic diagnosis was reported by pathologists as part of routine care. Of participants in the study, 55 (37%) were male and median (interquartile range) of age was 56 (19-80). Demographic, clinical characteristics, past medical history of patients, and the data obtained by two instruments were not significantly different and two methods detected similar number of polyps. In ST scope 89% of polyps were scope (P = 0.7). The ST scope had a positive predictive value (PPV) and positive likelihood ratio (PLR) of 86% and 4.0 for adenoma compared to 74% and 2.6 for HD scope. There was a trend of higher sensitivity for HD scope (68%) compare to ST scope (53%) with almost the same specificity. The ST scope had a PPV and PLR of 38% and 1.8 for hyperplastic polyp (HPP) compared to 42% and 2.2 for HD scope. The sensitivity and specificity of two instruments for HPP diagnosis were similar. Our results indicated that HD scope was more sensitive in diagnosis of adenoma than ST scope. Clinical diagnosis of HPP with either scope is less accurate compared to adenoma. Colonoscopy diagnosis is not yet fully matched with pathologic diagnosis of colon polyp. However with the advancement of both imaging and training, it may be possible to increase the sensitivity and specificity of the scopes and hence save money for eliminating time and the cost of Immunohistochemistry/pathology.

  8. Characterisation of human skin models - stability, metabolic capacity and comparative investigations in percutaneous absorption

    OpenAIRE

    Schreiber, Sylvia

    2010-01-01

    In recent years, the demand for alternative test methods in safety assessment of cosmetics, risk assessment of chemicals, and testing of pharmaceuticals was increasingly included in the EU directives. Thereby, alternative test methods for the determination of percutaneous absorption should achieve a more reliable in vivo prediction of the response of human skin than animal skin. Even though freshly excised human skin is considered as a preferred test matrix its routine use is often difficult ...

  9. Screened coulomb hybrid DFT investigation of band gap and optical absorption predictions of CuVO3, CuNbO3 and Cu 5Ta11O30 materials

    KAUST Repository

    Harb, Moussab

    2014-01-01

    We present a joint theoretical and experimental investigation of the optoelectronic properties of CuVO3, CuNbO3 and Cu 5Ta11O30 materials for potential photocatalytic and solar cell applications. In addition to the experimental results obtained by powder X-ray diffraction and UV-Vis spectroscopy of the materials synthesized under flowing N2 gas at atmospheric pressure via solid-state reactions, the electronic structure and the UV-Vis optical absorption coefficient of these compounds are predicted with high accuracy using advanced first-principles quantum methods based on DFT (including the perturbation theory approach DFPT) within the screened coulomb hybrid HSE06 exchange-correlation formalism. The calculated density of states are found to be in agreement with the UV-Vis diffuse reflectance spectra, predicting a small indirect band gap of 1.4 eV for CuVO3, a direct band gap of 2.6 eV for CuNbO3, and an indirect (direct) band gap of 2.1 (2.6) eV for Cu5Ta 11O30. It is confirmed that the Cu(i)-based multi-metal oxides possess a strong contribution of filled Cu(i) states in the valence band and of empty d0 metal states in the conduction band. Interestingly, CuVO3 with its predicted small indirect band gap of 1.4 eV shows the highest absorption coefficient in the visible range with a broad absorption edge extending to 886 nm. This novel result offers a great opportunity for this material to be an excellent candidate for solar cell applications. © the Partner Organisations 2014.

  10. Comparative Evaluation of Sealing Ability, Water Absorption, and Solubility of Three Temporary Restorative Materials: Anin vitroStudy.

    Science.gov (United States)

    Prabhakar, A R; Shantha Rani, N; V Naik, Saraswathi

    2017-01-01

    The quality of the coronal seal of root canal filling material is important for periapical health. Absorption of water or saliva by the temporary restorative materials leads to dimensional changes, loss of retention, staining and breaking in margin contours. Hence this study was carried out to evaluate and compare the sealing properties, water absorption and solubility of IRM (intermediate restorative material), Cavit G and GC Caviton. Experimental, in vitro intergroup randomized control trial. 36 non carious premolars were randomly selected assigned to three groups, 12 teeth in each. Standard endodontic access cavities of approximately 4x4mm wide were prepared followed by the root canal obturation with Gutta-percha and restoration with experimental materials. For microleakage testing dye penetration method was used with 2% methylene blue dye. Followed by evaluation and scoring under stereomicroscope at 40x magnification. Disc shaped 12 specimens for each group were prepared for each material, stored in desiccator at 37° C, weighed daily to verify mass stabilization (dry mass,m1). Thereafter, the specimens were stored in distilled water at 37°C for 7days to obtain the mass after saturation with water (m2). The specimens were placed in the desiccators again, at 37° C, and reweighed until a constant dry mass is obtained (m3). Water absorption (WS) and solubility (SL) was determined by using the formulas, WS = m3 - m2/V and SL= ml - m3/ V. GC Caviton showed least microleakage and least water absorption followed by IRM and Cavit G, the differences were statistically highly significant ( p Cavit G. Prabhakar AR, Rani NS, Naik SV. Comparative Evaluation of Sealing Ability, Water Absorption, and Solubility of Three Temporary Restorative Materials: An in vitro Study. Int J Clin Pediatr Dent 2017;10(2):136-141.

  11. Comparative studies of method for determining total mercury in fish. Dithizone and flameless atomic absorption spectrophotometry techniques

    International Nuclear Information System (INIS)

    Protasowicki, M.; Ociepa, A.; Chodyniecki, A.

    1977-01-01

    Two methods for determining total mercury in fish were compared: the dithizone and flameless atomic absorption spectrophotometry techniques. The studies involved determination of recovery when 1μg of mercury as solutions of HgCl 2 or CH 3 HgC were added to each sample of herring flesh. Mean recoveries in the dithizone method were found to be 91.4+-7.47% and 90.25+-4.73% for the two solutions respectively, while the recoveries obtained with the flameless atomic absorption spectrophotometry were 95.00+-9.13% and 98.70+-7.14%, respectively. Both techniques were used to determine the mercury content in the same herring flesh sample. The first technique showed the content of 0.050+-0.018μg Hg g -1 while the result obtained with the other one was 0.062+-0.013μg Hg g -1 . The statistical treatment of the results obtained showed no difference between the two techniques, the significance level being α=0.05. Therefore, the results obtained with the dithizone method are comparable with those obtained with the flameless atomic absorption spectrophotometry for mercury contents of the magnitude order of 0.050 ug.g -1 . (author)

  12. A parameterization for the absorption of solar radiation by water vapor in the earth's atmosphere

    Science.gov (United States)

    Wang, W.-C.

    1976-01-01

    A parameterization for the absorption of solar radiation as a function of the amount of water vapor in the earth's atmosphere is obtained. Absorption computations are based on the Goody band model and the near-infrared absorption band data of Ludwig et al. A two-parameter Curtis-Godson approximation is used to treat the inhomogeneous atmosphere. Heating rates based on a frequently used one-parameter pressure-scaling approximation are also discussed and compared with the present parameterization.

  13. Comparative full-band Monte Carlo study of Si and Ge with screened pseudopotential-based phonon scattering rates

    Science.gov (United States)

    Nguyen, Phuong Hoa; Hofmann, Karl R.; Paasch, Gernot

    2003-07-01

    In a previous article [J. Appl. Phys. 92, 5359 (2002)], we presented a combination of a full-band Monte Carlo method using an advanced band structure and a variable Brillouin zone discretization, with phonon scattering rates based on the screened pseudopotential considering the positions of the atoms in the elementary cell. To make the method suitable for sufficiently fast applications, such as device simulations, the simplest wave number dependent approximation was introduced. It contains an average of the cell structure factor, and only two fit parameters: The acoustic and the optical deformation potentials. As the pseudopotential, the Ashcroft model potential is chosen, and screening is taken into account using the Lindhard dielectric function. In the present article, based on the study of the influence of the two deformation potentials on the electron and hole drift velocities in Si and Ge, we show how to select the deformation potentials. Depending on the targeted agreement with experimental results, the pairs of deformation potentials for electrons and holes can be used uniformly for a wide temperature range or separately for different temperatures. For Ge, we achieve remarkable quantitative agreement with the temperature, field, and orientation dependencies of experimental electron and hole drift velocities in the wide temperature range from 77 to 300 K with a single set of the two deformations potentials for each carrier type. A detailed comparative simulation of the transport properties in Ge and Si at different temperatures is presented which is comprised of the steady-state dependence of the drift velocity on the electric field, the low-field mobility, and transient transport. Peculiarities of the drift velocity-field dependencies, such as the anisotropy, and a negative differential mobility are discussed in terms of the different band structures in connection with the field dependence of the simulated distribution functions. For doped materials, ionized

  14. Near-infrared diode laser based spectroscopic detection of ammonia: a comparative study of photoacoustic and direct optical absorption methods

    Science.gov (United States)

    Bozoki, Zoltan; Mohacsi, Arpad; Szabo, Gabor; Bor, Zsolt; Erdelyi, Miklos; Chen, Weidong; Tittel, Frank K.

    2002-01-01

    A photoacoustic spectroscopic (PAS) and a direct optical absorption spectroscopic (OAS) gas sensor, both using continuous-wave room-temperature diode lasers operating at 1531.8 nm, were compared on the basis of ammonia detection. Excellent linear correlation between the detector signals of the two systems was found. Although the physical properties and the mode of operation of both sensors were significantly different, their performances were found to be remarkably similar, with a sub-ppm level minimum detectable concentration of ammonia and a fast response time in the range of a few minutes.

  15. Absorption spectrum and absorption cross sections of the 2ν1 band of HO2 between 20 and 760 Torr air in the range 6636 and 6639 cm-1

    Science.gov (United States)

    Assaf, Emmanuel; Liu, Lu; Schoemaecker, Coralie; Fittschen, Christa

    2018-05-01

    The absorption spectrum of HO2 radicals has been measured in the range 6636-6639 cm-1 at several pressures between 20 and 760 Torr of air. Absolute absorption cross sections of the strongest line at around 6638.2 cm-1 have been determined from kinetic measurements, taking advantage of the well known rate constant of the self-reaction. Peak absorption cross sections of 22.6, 19.5, 14.4, 7.88, 5.12 and 3.23 × 10-20 cm2 were obtained at 20, 50, 100, 200, 400 and 760 Torr, respectively. By fitting these data, an empirical expression has been obtained for the absorption cross section of HO2 in the range 20-760 Torr air: σ6638.2cm-1 = 1.18 × 10-20 + (2.64 × 10-19 × (1-exp (-63.1/p (Torr))) cm2.

  16. A retrospective comparative study of histoacryl injection and banding ligation in the treatment of acute type 1 gastric variceal hemorrhage.

    Science.gov (United States)

    Lo, Gin-Ho; Lin, Chih-Wen; Perng, Daw-Shyong; Chang, Chi-Yang; Lee, Ching-Tai; Hsu, Chuan-Yuan; Wang, Huay-Min; Lin, Hui-Chen

    2013-10-01

    BACKGROUND. Esophageal varices extending along lesser curvature side of stomach is classified as GOV1. The optimal therapy for GOV1 bleeding is still undetermined. METHODS. One hundred and sixty-two patients diagnosed as acute hemorrhage from GOV1 were enrolled. At endoscopists' discretion, 118 patients received glue injection (Glue group) and 44 patients received ligation to arrest bleeding [endoscopic variceal ligation (EVL) group]. This study aimed to compare hemostasis, rebleeding, complications and mortality within 42 days. RESULTS. Both groups were comparable in baseline data. In 109 patients (92%) in the Glue group and 36 patients (82%) in the EVL group (p = 0.07) 48-h hemostasis was achieved . Hemostasis of active bleeding was achieved in 49 of 55 patients (89%) in the Glue group and 24 of 28 patients (85%) in the EVL group (p = 0.70). Treatment failure was noted in 14% of the Glue group and 23% in the EVL group (p = 0.22). Eight patients in the Glue group and four patients in the EVL group rebled between 5 and 42 days (p = 0.73). A total of 48 and 19 adverse events occurred in the Glue and EVL groups, respectively (p = 0.85). Six patients in the Glue group and seven patients in the EVL group encountered posttreatment gastric ulcer bleeding (p = 0.04). Seventeen patients (14%) in the Glue group and 10 (23%) patients in the EVL group died within 42 days (p < 0.001). CONCLUSIONS. Banding ligation was similar to glue injection in achieving successful hemostasis of acute bleeding from GOV1. However, a higher incidence of posttreatment ulcer bleeding and mortality may be associated with banding ligation.

  17. Development and Ecological-Energy Comparative Analysis оf Vapor Compression and Solar Absorption Schemes of Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2017-12-01

    Full Text Available The mission of the research included the following objectives: the development of new circuit decisions for the alternate refrigerating systems based on the use of an open absorptive circuit and on the use of solar energy for absorbent solution regeneration; an assessment of the energy and envi-ronmental characteristics of the developed systems; obtaining of the experimental data for an assess-ment of the principal capabilities of the proposed new solar air-conditioning systems. New principles for design of heat and mass transfer equipment in the version with a movable packing of heat exchange elements (fluidized bed packing "gas - liquid - solid body" placed in the packed bed were developed, which allows self-cleaning of the working surfaces and walls of the heat and mass transfer equipment HMT. This new solution, when working with outdoor air and solutions of absorbents, seems to be a fundamentally important condition for maintaining the working capacity of solar absorption systems. The new schemes of absorber with internal steam cooling allowing the improve-ment of the new scheme of the alternate refrigerating system were developed. Comparative analysis based on the methodology of the "Life Cycle Assessment" (LCA showed that new, developed solar systems provide the considerable decrease in energy consumption, their use leads to the decrease of exhaustion of natural resources, influences less global climate change.

  18. ISO-SWS observations of infrared absorption bands of the diffuse interstellar medium : The 6.2 mu m feature of aromatic compounds

    NARCIS (Netherlands)

    Schutte, WA; van der Hucht, KA; Whittet, DCB; Boogert, ACA; Tielens, AGGM; Morris, PW; Greenberg, JM; Williams, PM; van Dishoeck, EF; Chiar, JE; de Graauw, T

    We present ISO-SWS spectroscopy of eight strong infrared sources with large extinction through the diffuse interstellar medium. These are five late-type Wolf-Rayet stars, the blue hypergiant Cyg OB2 #12 and the Galactic Center Sources 3 and 4. The spectra show a number of absorption features that

  19. Below band-gap optical absorption and photoluminescence excitation spectroscopy at room temperature in low-defect-density bulk GaN:Fe

    Czech Academy of Sciences Publication Activity Database

    Gladkov, Petar; Hulicius, Eduard; Paskova, T.; Preble, E.; Evans, K.R.

    2012-01-01

    Roč. 100, č. 3 (2012), "031908-1"-"031908-3" ISSN 0003-6951 Grant - others:US Missile Defense Agency(US) HQ 0147-09-C-0005 Institutional support: RVO:68378271 ; RVO:67985882 Keywords : GaN * spectroscopy * optical absorption Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.794, year: 2012

  20. Effects of Nordic Walking Compared to Conventional Walking and Band-Based Resistance Exercise on Fitness in Older Adults

    Science.gov (United States)

    Takeshima, Nobuo; Islam, Mohammod M.; Rogers, Michael E.; Rogers, Nicole L.; Sengoku, Naoko; Koizumi, Daisuke; Kitabayashi, Yukiko; Imai, Aiko; Naruse, Aiko

    2013-01-01

    The purpose of this study was to compare the effects of Nordic walking with conventional walking and band-based resistance exercise on functional fitness, static balance and dynamic balance in older adults. Volunteers (n = 65) were divided into four groups: Nordic walking (NW), conventional walking (CW), resistance (RES), and control. Each group performed activity 50-70 min·day−1 (warm-up 10-15 min, main exercise 30-40, and cool down 10-15 min), 3 days·week−1 (NW and CW) or 2 day·week−1 (RES) for 12 wks. Upper-body strength improved (p Cardio- respiratory fitness improved more in the NW (10.9%) and CW (10.6%) groups compared to the RES and control groups. Upper- and lower-body flexibility also improved in all exercise groups compared to the control group. There were no improvements in balance measures in any group. While all modes of exercise improved various components of fitness, Nordic walking provided the best well-rounded benefits by improving upper-body strength, cardiovascular endurance, and flexibility. Therefore, Nordic walking is recommended as an effective and efficient mode of concurrent exercise to improve overall functional fitness in older adults. Key Points Nordic walking, conventional walking, and resistance training are beneficial for older adults. Nordic walking and conventional walking both improve cardio-respiratory fitness while resistance training does not. Nordic walking provides additional benefits in upper-body muscular strength compared to conventional walking. Nordic walking is an effective and efficient mode of exercise to improve overall fitness in older adults. PMID:24149147

  1. Comparative effectiveness of 3 bariatric surgery procedures: Roux-en-Y gastric bypass, laparoscopic adjustable gastric band, and sleeve gastrectomy.

    Science.gov (United States)

    Lee, Jenny H; Nguyen, Quynh-Nhu; Le, Quang A

    2016-06-01

    Bariatric surgery is associated with improved co-morbidities, quality of life, and survival in severely obese patients. Common bariatric surgery procedures include Roux-en-Y gastric bypass (RYGB), laparoscopic adjustable gastric band (LAGB), and sleeve gastrectomy (SG). Currently, literature studying comparative effectiveness on different bariatric surgery procedures in veterans is limited. To compare effectiveness of 3 bariatric surgery procedures performed in veterans. Veterans Affairs Loma Linda Healthcare Systems (VALLHS), Loma Linda, California, United States. This study was a single-institution, retrospective cohort study. Primary outcome was weight reduction, expressed as kilograms lost, body mass index (BMI) reduction, percentage weight loss (%WL), and percentage excess weight loss (%EWL) after 12 months of bariatric surgery. Secondary outcomes were reduction in number of medications and laboratory markers for obesity-related chronic conditions. Inverse-probability weighting propensity score method was used to balance baseline characteristics among the procedures. A total of 162 patients were included in the study. At 12 months, the kilograms lost, BMI reduction, %WL, and %EWL were 40.7±14.5 kg, 13.4±4.1 kg/m(2), 31.5±8.5%, and 41.4±11.6% for RYGB; 24.4±22.1 kg, 7.9±7.3 kg/m(2), 20.2±21.5%, and 26.7±27.6% for SG; and 15.3±15.7 kg, 5.0±5.0 kg/m(2), 12.0±11.7%, and 16.1±15.9% for LAGB, respectively (RYGB versus SG, RYGB versus LAGB, and SG versus LAGB, all Psurgery procedure in patients who are not candidates for RYGB. Copyright © 2016 American Society for Bariatric Surgery. All rights reserved.

  2. Absorption kinetics of two highly concentrated preparations of growth hormone: 12 IU/ml compared to 56 IU/ml

    DEFF Research Database (Denmark)

    Laursen, Torben; Susgaard, Søren; Jensen, Flemming Steen

    1994-01-01

    AbstractSend to: Pharmacol Toxicol. 1994 Jan;74(1):54-7. Absorption kinetics of two highly concentrated preparations of growth hormone: 12 IU/ml compared to 56 IU/ml. Laursen T1, Susgaard S, Jensen FS, Jørgensen JO, Christiansen JS. Author information Abstract The purpose of this study...... was to compare the relative bioavailability of two highly concentrated (12 IU/ml versus 56 IU/ml) formulations of biosynthetic human growth hormone administered subcutaneously. After pretreatment with growth hormone for at least four weeks, nine growth hormone deficient patients with a mean age of 26.2 years...... (range 17-43) were studied two times in a randomized design, the two studies being separated by at least one week. At the start of each study period (7 p.m.), growth hormone was injected subcutaneously in a dosage of 3 IU/m2. The 12 IU/ml preparation of growth hormone was administered on one occasion...

  3. Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation.

    Science.gov (United States)

    Assad, M; Lemieux, N; Rivard, C H; Yahia, L H

    1999-01-01

    The genotoxicity level of nickel-titanium (NiTi) was compared to that of its pure constituents, pure nickel (Ni) and pure titanium (Ti) powders, and also to 316L stainless steel (316L SS) as clinical reference material. In order to do so, a dynamic in vitro semiphysiological extraction was performed with all metals using agitation and ISO requirements. Peripheral blood lymphocytes were then cultured in the presence of all material extracts, and their comparative genotoxicity levels were assessed using electron microscopy-in situ end-labeling (EM-ISEL) coupled to immunogold staining. Cellular chromatin exposition to pure Ni and 316L SS demonstrated a significantly stronger gold binding than exposition to NiTi, pure Ti, or the untreated control. In parallel, graphite furnace atomic absorption spectrophotometry (AAS) was also performed on all extraction media. The release of Ni atoms took the following decreasing distribution for the different resulting semiphysiological solutions: pure Ni, 316L SS, NiTi, Ti, and controls. Ti elements were detected after elution of pure titanium only. Both pure titanium and nickel-titanium specimens obtained a relative in vitro biocompatibility. Therefore, this quantitative in vitro study provides optimistic results for the eventual use of nickel-titanium alloys as surgical implant materials.

  4. A comparative cepstral based analysis of simulated and measured S-band and X-band radar Doppler spectra of human motion

    CSIR Research Space (South Africa)

    Van Eeden, WD

    2015-10-01

    Full Text Available A simulation for human Doppler response is developed based on the Carnegie Mellon University motion capture database. This data is used to simulate human Doppler response as it would be seen by a radar system and this data is compared to measured...

  5. Comparative Analysis Electroencephalographic of Alpha, Beta and Gamma Bands of a Healthy Individual and One with Hemiparesis

    Science.gov (United States)

    Machado, Dionis de Castro Dutra; Lima, Glenda Crispim; Souza dos Santos, Rodrigo; Ramos, Amanda Júlia Bezerra; Menezes de Sousa, Cáio César; Moreira dos Santos, Rayele Pricila; Coelho, Karyna Kelly Oliveira; Cagy, Mauricio; Orsini, Marco; Bastos, Victor Hugo

    2014-01-01

    [Purpose] The study analyzed the electroencephalographic (EEG) data of the central cortical areas, during execution of the motor gestures of feeding, activation of the system of mirror neurons, and imagery between a right hemiparetic volunteer (RHV) and a healthy volunteer (HV). [Subjects and Methods] The volunteers’ EEG data were recorded with their eyes open for 4 minutes while they performed five experimental tasks. [Results] The alpha band, absolute power value of HV was lower than that of RHV. In the beta band, during the practice condition, there was an increase in the magnitude of the absolute power value of HV at T3, possibly because T3 is representative of secondary motor areas that work with cortical neurons related to planning and organizing sequence of movements performed by the hands. The gamma band is related to the state of preparation for movement and memory. The results of this study indicate that there was increased activation of the gamma frequency band of HV. [Conclusion] The findings of this study have revealed the changes in pattern characteristics of each band which may be associated with the brain injury of the hemiparetic patient. PMID:25013270

  6. Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: Comparative study of different chemical modifiers

    Energy Technology Data Exchange (ETDEWEB)

    Vilar Farinas, M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Barciela Garcia, J. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Garcia Martin, S. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena Crecente, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Herrero Latorre, C. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)]. E-mail: cherrero@lugo.usc.es

    2007-05-22

    In this work, several analytical methods are proposed for cadmium determination in Orujo spirit samples using electrothermal atomic absorption spectrometry (ETAAS). Permanent chemical modifiers thermally coated on the platforms inserted in pyrolytic graphite tubes (such as W, Ir, Ru, W-Ir and W-Ru) were comparatively studied in relation to common chemical modifier mixtures [Pd-Mg(NO{sub 3}){sub 2} and (NH{sub 4})H{sub 2}PO{sub 4}-Mg(NO{sub 3}){sub 2}] for cadmium stabilization. Different ETAAS Cd determination methods based on the indicated modifiers have been developed. In each case, pyrolysis and atomization temperatures, atomization shapes, characteristic masses and detection limits as well as other analytical characteristics have been determined. All the assayed modifiers (permanent and conventional) were capable of achieving the appropriate stabilization of the analyte, with the exception of Ru and W-Ru. Moreover, for all developed methods, recoveries (99-102%) and precision (R.S.D. lower than 10%) were acceptable. Taking into account the analytical performance (best detection limit LOD = 0.01 {mu}g L{sup -1}), the ETAAS method based on the use of W as a permanent modifier was selected for further direct Cd determinations in Orujo samples from Galicia (NW Spain). The chosen method was applied in the determination of the Cd content in 38 representative Galician samples. The cadmium concentrations ranged

  7. Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: Comparative study of different chemical modifiers

    International Nuclear Information System (INIS)

    Vilar Farinas, M.; Barciela Garcia, J.; Garcia Martin, S.; Pena Crecente, R.; Herrero Latorre, C.

    2007-01-01

    In this work, several analytical methods are proposed for cadmium determination in Orujo spirit samples using electrothermal atomic absorption spectrometry (ETAAS). Permanent chemical modifiers thermally coated on the platforms inserted in pyrolytic graphite tubes (such as W, Ir, Ru, W-Ir and W-Ru) were comparatively studied in relation to common chemical modifier mixtures [Pd-Mg(NO 3 ) 2 and (NH 4 )H 2 PO 4 -Mg(NO 3 ) 2 ] for cadmium stabilization. Different ETAAS Cd determination methods based on the indicated modifiers have been developed. In each case, pyrolysis and atomization temperatures, atomization shapes, characteristic masses and detection limits as well as other analytical characteristics have been determined. All the assayed modifiers (permanent and conventional) were capable of achieving the appropriate stabilization of the analyte, with the exception of Ru and W-Ru. Moreover, for all developed methods, recoveries (99-102%) and precision (R.S.D. lower than 10%) were acceptable. Taking into account the analytical performance (best detection limit LOD = 0.01 μg L -1 ), the ETAAS method based on the use of W as a permanent modifier was selected for further direct Cd determinations in Orujo samples from Galicia (NW Spain). The chosen method was applied in the determination of the Cd content in 38 representative Galician samples. The cadmium concentrations ranged -1

  8. COMPARATIVE STUDY BETWEEN TENSION BAND WIRING OF PATELLAR FRACTURES WITH KIRSCHNER WIRES AND CANNULATED SCREWS IN TERMS OF FUNCTIONAL OUTCOME AND COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Kumaran Chettiar

    2016-11-01

    Full Text Available BACKGROUND Various treatment modalities are described for the treatment of displaced transverse fractures of patella. As patella is very important biomechanically, open reduction and internal fixation with maximal preservation of patella is the standard treatment. Most commonly used method is modified tension band wiring with Kirschner wires. In a modification, cannulated screws are used instead of K wires and wire is passed through the cannulation of the screw and anterior surface of the patella. The aim of our study was to compare the complications and functional outcomes after surgical treatment of patellar fractures using modified tension band wiring with Kirschner wires and with cannulated screws. MATERIALS AND METHODS This study was conducted in Department of Orthopaedics, Government Medical College, Kozhikode, during the period 2014- 2015. Total sample size was 36. They were randomised into two groups. Among them, 17 had undergone tension band wiring with cannulated screws and 19 with Kirschner wires. They were evaluated in postoperative period at 1 month, 3 months and 6 months by looking for complications like postoperative infection, postoperative loss of reduction, skin irritation by prominent hardware. Functional outcome was assessed by knee pain score and Good Fellows grading of range of motion. RESULTS According to this study while comparing these two surgical techniques, there are no statistically significant differences in terms of complications and functional outcome. We observed that cannulated screw with tension band wiring has better patient tolerance, less complications like skin irritation by prominent hardware, loss of fixation and knee pain. We found that tension band wiring through cannulated screws is technically more difficult than using Kirschner wires. CONCLUSION Although, the statistical analysis showed no significant differences regarding the union and final outcome, cannulated screw with tension band wiring has

  9. Excitons and trions in monolayer transition metal dichalcogenides: A comparative study between the multiband model and the quadratic single-band model

    Science.gov (United States)

    Van der Donck, M.; Zarenia, M.; Peeters, F. M.

    2017-07-01

    The electronic and structural properties of excitons and trions in monolayer transition metal dichalcogenides are investigated using both a multiband and a single-band model. In the multiband model we construct the excitonic Hamiltonian in the product base of the single-particle states at the conduction and valence band edges. We decouple the corresponding energy eigenvalue equation and solve the resulting differential equation self-consistently, using the finite element method (FEM), to determine the energy eigenvalues and the wave functions. As a comparison, we also consider the simple single-band model which is often used in numerical studies. We solve the energy eigenvalue equation using the FEM as well as with the stochastic variational method (SVM) in which a variational wave function is expanded in a basis of a large number of correlated Gaussians. We find good agreement between the results of both methods, as well as with other theoretical works for excitons, and we also compare with available experimental data. For trions the agreement between both methods is not as good due to our neglect of angular correlations when using the FEM. Finally, when comparing the two models, we see that the presence of the valence bands in the mutiband model leads to differences with the single-band model when (interband) interactions are strong.

  10. A comparative study of EL2 and other deep centers in undoped SI GaAs using optical absorption spectra and photoconductivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kozlova, J.P. E-mail: jpkozlova@rbcmail.ru; Bowles, T.J.; Eremin, V.K.; Gavrin, V.N.; Koshelev, O.G.; Markov, A.V.; Morozova, V.A.; Polyakov, A.J.; Verbitskaya, E.M.; Veretenkin, E.P

    2003-10-11

    The performance of radiation detectors fabricated from semi-insulating (SI) GaAs is highly sensitive to EL2{sup +}-concentration in the material. Near-infrared optical absorption measurements are commonly used to determine the EL2-concentration and to roughly estimate the EL2{sup +}-concentration under the assumption that the optical absorption is mainly determined by the photoionization and the photoneutralization of EL2{sup 0} and EL2{sup +}, respectively. However, the presence of different native defects can contribute to optical absorption and reduce the precision of determination of EL2-concentration. In this work, we evaluate the contributions into optical absorption from EL2 and other deep center namely EL3 defect (0.55 eV) using near-infrared optical absorption and photoconductivity (PC) measurements in the photon energy interval 0.5-1.4 eV for SI GaAs crystals grown by the liquid encapsulated Czochralski method from melts with As content changing from 50% to about 46%. The photoelectrical spectra were measured on p-i-n structure detectors with heavily doped p{sup +} and n{sup +} layers grown by Liquid Phase Epitaxy and on Schottky diodes. The short circuit photocurrent spectra were registered for all detectors in the energy interval 0.65-1.4 eV. Unexpectedly, the current sensitivities in the regions of the extrinsic and intrinsic absorption were comparable. A comparative study of optical absorption, PC and short circuit photocurrent spectra resulted in determination of EL2{sup +}-concentration. It was concluded that contribution of additional deep centers, particularly the ionized EL3{sup +} defect could be comparable to the EL2-contribution. The EL3 centers were attributed to oxygen-related defects based on published results and on some indirect evidence in our experimental data.

  11. The spectral-line moment-based (SLMB) modeling of the wide band and global blackbody-weighted transmission function and cumulative distribution function of the absorption coefficient in uniform gaseous media

    Energy Technology Data Exchange (ETDEWEB)

    Andre, Frederic [Centre de Thermique de Lyon (CETHIL, CNRS-INSA Lyon-UCBL), Bat. Sadi Carnot, INSA-Lyon, Lyon F-69621 (France)], E-mail: frederic.andre@insa-lyon.fr; Vaillon, Rodolphe [Centre de Thermique de Lyon (CETHIL, CNRS-INSA Lyon-UCBL), Bat. Sadi Carnot, INSA-Lyon, Lyon F-69621 (France)

    2008-09-15

    The spectral-line moment-based (SLMB) modeling is proposed for the calculation of radiative properties of gases on any spectral width. The associated mathematical formulation is obtained by applying several concepts of the k-distribution methods such as the reordering of the wavenumber scale by monotonic variations of the absorption coefficient, together with the application of the k-moment method's principles. This approach gives both a general formula for the BTF and a simple and readily applicable approximation for the blackbody-weighted cumulated k-distribution function of the absorption coefficient. The model is applied for the computation of wide band BTFs and cumulative k-distributions for uniform columns of CO{sub 2} and H{sub 2}O in the temperature range (300-2400 K) at atmospheric pressure. Model parameters are deduced from line-by-line (LBL) spectra calculated using the HITEMP database. Comparisons with LBL reference data as well as with contemporary modeling approaches (SLW, FSK, SNB) are performed and discussed.

  12. Protonation effects on the UV/Vis absorption spectra of imatinib: A theoretical and experimental study

    Science.gov (United States)

    Grante, Ilze; Actins, Andris; Orola, Liana

    2014-08-01

    An experimental and theoretical investigation of protonation effects on the UV/Vis absorption spectra of imatinib showed systematic changes of absorption depending on the pH, and a new absorption band appeared below pH 2. These changes in the UV/Vis absorption spectra were interpreted using quantum chemical calculations. The geometry of various imatinib cations in the gas phase and in ethanol solution was optimized with the DFT/B3LYP method. The resultant geometries were compared to the experimentally determined crystal structures of imatinib salts. The semi-empirical ZINDO-CI method was employed to calculate the absorption lines and electronic transitions. Our study suggests that the formation of the extra near-UV absorption band resulted from an increase of imatinib trication concentration in the solution, while the rapid increase of the first absorption maximum could be attributed to both the formation of imatinib trication and tetracation.

  13. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.

    Science.gov (United States)

    De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P

    2015-06-30

    Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10μL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Inhibition of starch absorption by dietary fibre. A comparative study of wheat bran, sugar-beet fibre, and pea fibre

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    The effect of dietary fibre on starch absorption was investigated in 8 healthy subjects. Amounts of starch escaping small-bowel absorption was assessed by comparison of breath H2 excretion after test meals and after lactulose (10g). After ingestion of bread made from 100g of wheat flour increases...... that the dietary fibres used in this impaired the absorption of wheat starch and thereby increased the amount of starch-derived carbohydrate available for colonic fermentation....... in H2 excretion occurred in all subjects; the calculated fractions of unabsorbed starch ranged from 4% to 17% (median, 8%). Concurrent ingestion of this bread with either wheat bran, sugar-beet fibre, or pea fibre increased the fraction of unabsorbed starch to 12.5% (5-22%) (p less than 0.05), 12.5% (5...

  15. Bioavailable iron in typical Thai meals: Comparative studies between radioactive in vitro and in vivo food iron absorption measurements

    International Nuclear Information System (INIS)

    Sritongkul, N.

    1989-03-01

    Presently available in vivo methods for assessing iron absorption in human subjects, although physiologically acceptable and accurate, are not practical for screening large numbers of food and diet samples. A simple in vitro method for determining the amount of iron available for absorption was therefore investigated. It is based on the common pool concept of food iron absorption using radioactive Fe-59 as a marker of the iron present in the bioavailable iron pool. The ionizable iron was measured after an initial peptic digestion by using pepsin/HCl at pH 1.35 followed by an increase of the pH to 6.0 to simulate duodenal alkalinity. The method was proved to be simple, reproducible and applicable either to single food items or whole meals of varying composition. It is able to detect known enhancers or inhibitors of food iron absorption. The percent ionizable iron among 5 different meals with the inclusion of inhibitor or enhancer was shown to correlate closely with the percentage of iron absorbed in human subjects (r=0.9197, p<0.001). A high correlation between the in vivo and in vitro methods was also observed when the results were expressed as absorption ratios and ionizable ratios (r=0.9192, p<0.001). The method is expected to be useful for improving diet composition to increase the iron availability of some typical meals in developing countries, including those which are known to contain considerable amounts of inhibitors of iron absorption. 39 refs, 1 fig., 13 tabs

  16. Detection of trans-isomers of hydrocarbon residues of lipid molecules by IR absorption

    Science.gov (United States)

    Mikhalovsky, I. S.; Samoylov, M. V.; Wileishikova, N. P.

    2009-01-01

    IR spectroscopy is used for a comparative analysis of the trans-isomerization of double bonds in hydrocarbon residuals of lactic and hydrogenated lipids. The maximum of the absorption band of the trans-isomers for all the lipid samples is found to lie at 965 cm-1. An absorption band at 970 cm-1 is discovered in the spectra of the lactic lipids near the analytic band of the trans-isomers at 965 cm-1. Based on a gaussian approximation for their absorption spectral bands, the trans-isomer content in the lactic lipid samples is 10-11%. The absorption by lipid molecules at 970 cm-1 has to be taken into account when determining the trans-isomer content of fat and oil products.

  17. Pseudopotential calculations and photothermal lensing measurements of two-photon absorption in solids

    International Nuclear Information System (INIS)

    White, W.T. III.

    1985-01-01

    We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in order to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs

  18. Pseudopotential calculations and photothermal lensing measurements of two-photon absorption in solids

    Energy Technology Data Exchange (ETDEWEB)

    White, W.T. III

    1985-11-04

    We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in order to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs.

  19. A comparative study of solution-processed low- and high-band-gap chalcopyrite thin-film solar cells

    International Nuclear Information System (INIS)

    Park, Se Jin; Moon, Sung Hwan; Min, Byoung Koun; Cho, Yunae; Kim, Ji Eun; Kim, Dong-Wook; Lee, Doh-Kwon; Gwak, Jihye; Kim, Jihyun

    2014-01-01

    Low-cost and printable chalcopyrite thin-film solar cells were fabricated by a precursor solution-based coating method with a multi-step heat-treatment process (oxidation, sulfurization, and selenization). The high-band-gap (1.57 eV) Cu(In x Ga 1−x )S 2 (CIGS) solar cell showed a high open-circuit voltage of 787 mV, whereas the low-band-gap (1.12 eV) Cu(In x Ga 1−x )(S 1−y Se y ) 2 (CIGSSe) cell exhibited a high short-circuit current density of 32.6 mA cm −2 . The energy conversion efficiencies were 8.28% for CIGS and 8.81% for CIGSSe under standard irradiation conditions. Despite similar efficiencies, the two samples showed notable differences in grain size, surface morphology, and interfacial properties. Low-temperature transport and admittance characteristics of the samples clearly revealed how their structural differences influenced their photovoltaic and electrical properties. Such analyses provide insight into the enhanced solar cell performance of the solution-processed chalcopyrite thin films. (paper)

  20. Flow Cytometric DNA index, G-band Karyotyping, and Comparative Genomic Hybridization in Detection of High Hyperdiploidy in Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Larsen, Jacob; Kristensen, Tim D

    2006-01-01

    High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic hybridiza......High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic...... hybridization (HR-CGH) in detecting high hyperdiploid leukemic clones. Twenty-six girls and 34 boys with acute lymphoblastic leukemia diagnosed in 1998 to 1999 were analyzed by FCM, GBK, and HR-CGH. The correlations between DNA indices obtained by FCM, GBK, and HR-CGH were significant (rs=0.61 to 0.77; P

  1. Multiplex ligation-dependent probe amplification assay identifies additional copy number changes compared with R-band karyotype and provide more accuracy prognostic information in myelodysplastic syndromes.

    Science.gov (United States)

    Wang, Jingya; Ai, Xiaofei; Qin, Tiejun; Xu, Zefeng; Zhang, Yue; Liu, Jinqin; Li, Bing; Fang, Liwei; Zhang, Hongli; Pan, Lijuan; Hu, Naibo; Qu, Shiqiang; Cai, Wenyu; Ru, Kun; Jia, Yujiao; Huang, Gang; Xiao, Zhijian

    2017-01-03

    Cytogenetic analysis provides important diagnostic and prognostic information for patients with Myelodysplastic syndromes (MDS) and plays an essential role in the International Prognostic Scoring System (IPSS) and the revised International Prognostic Scoring System (IPSS-R). Multiplex ligation-dependent probe amplification (MLPA) assay is a recently developed technique to identify targeted cytogenetic aberrations in MDS patients. In the present study, we evaluated the results obtained using an MLPA assay in 437 patients with MDS to determine the efficacy of MLPA analysis. Using R-banding karyotyping, 45% (197/437) of MDS patients had chromosomal abnormalities, whereas MLPA analysis detected that 35% (153/437) of MDS cases contained at least one copy-number variations (CNVs) .2/5 individuals (40%) with R-band karyotype failures had trisomy 8 detected using only MLPA. Clonal cytogenetic abnormalities were detected in 20/235 (8.5%) MDS patients with a normal R-band karyotype, and 12/20 (60%) of those patients were reclassified into a higher-risk IPSS-R prognostic category. When sequencing and cytogenetics were combined, the fraction of patients with MDS-related oncogenic lesions increased to 87.3% (233/267 cases). MLPA analysis determined that the median OS of patients with a normal karyotype (n=218) was 65 months compared with 27 months in cases with an aberrant karyotype (P=0.002) in 240 patients with normal or failed karyotypes by R-banding karyotyping. The high-resolution MPLA assay is an efficient and reliable method that can be used in conjunction with R-band karyotyping to detect chromosomal abnormalities in patients with suspected MDS. MLPA may also provide more accurate prognostic information.

  2. Threshold nonlinear absorption in Zeeman transitions

    International Nuclear Information System (INIS)

    Narayanan, Andal; Hazra, Abheera; Sandhya, S N

    2010-01-01

    We experimentally study the absorption spectroscopy from a collection of gaseous 87 Rb atoms at room temperature irradiated with three fields. Two of these fields are in a pump-probe saturation absorption configuration. The third field co-propagates with the pump field. The three fields address Zeeman degenerate transitions between hyperfine levels 5S 1/2 , F = 1 and 5P 3/2 , F = 0, F = 1 around the D2 line. We find a sub-natural absorption resonance in the counter-propagating probe field for equal detunings of all three fields. This absorption arises in conjunction with the appearance of increased transmission due to electro-magnetically induced transparency in the co-propagating fields. The novel feature of this absorption is its onset only for the blue of 5P 3/2 , F = 0, as the laser frequency is scanned through the excited states 5P 3/2 , F = 0, F = 1 and F = 2. The absorption rapidly rises to near maximum values within a narrow band of frequency near 5P 3/2 , F = 0. Our experimental results are compared with a dressed atom model. We find the threshold absorption to be a result of coherent interaction between the dressed states of our system.

  3. Grain size dependent optical band gap of CdI2 films

    Indian Academy of Sciences (India)

    Unknown

    direct band gap in conformity with band structure calcula- tions. However, a smaller indirect band gap can also be determined from part of absorption data near the band edge for the purpose of comparison with earlier analyses of absorption data as well as the band structure calcula- tions. The decreasing band gap with film ...

  4. A Comparative Study of Molecular Structure, pKa, Lipophilicity, Solubility, Absorption and Polar Surface Area of Some Antiplatelet Drugs

    Directory of Open Access Journals (Sweden)

    Milan Remko

    2016-03-01

    Full Text Available Theoretical chemistry methods have been used to study the molecular properties of antiplatelet agents (ticlopidine, clopidogrel, prasugrel, elinogrel, ticagrelor and cangrelor and several thiol-containing active metabolites. The geometries and energies of most stable conformers of these drugs have been computed at the Becke3LYP/6-311++G(d,p level of density functional theory. Computed dissociation constants show that the active metabolites of prodrugs (ticlopidine, clopidogrel and prasugrel and drugs elinogrel and cangrelor are completely ionized at pH 7.4. Both ticagrelor and its active metabolite are present at pH = 7.4 in neutral undissociated form. The thienopyridine prodrugs ticlopidine, clopidogrel and prasugrel are lipophilic and insoluble in water. Their lipophilicity is very high (about 2.5–3.5 logP values. The polar surface area, with regard to the structurally-heterogeneous character of these antiplatelet drugs, is from very large interval of values of 3–255 Å2. Thienopyridine prodrugs, like ticlopidine, clopidogrel and prasugrel, with the lowest polar surface area (PSA values, exhibit the largest absorption. A high value of polar surface area (PSA of cangrelor (255 Å2 results in substantial worsening of the absorption in comparison with thienopyridine drugs.

  5. Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: a comparative study.

    Science.gov (United States)

    Cabon, J Y; Giamarchi, P; Le Bihan, A

    2010-04-07

    Two methods available for direct determination of total Fe in seawater at low concentration level have been examined: electrothermal atomization atomic absorption spectrometry (ETAAS) and electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS). In a first part, we have optimized experimental conditions of ETAAS (electrothermal program, matrix chemical modification) for the determination of Fe in seawater by minimizing the chemical interference effects and the magnitude of the simultaneous background absorption signal. By using the best experimental conditions, a detection limit of 80 ng L(-1) (20 microL, 3sigma) for total Fe concentration was obtained by ETAAS. Using similar experimental conditions (electrothermal program, chemical modification), we have optimized experimental conditions for the determination of Fe by LEAFS. The selected experimental conditions for ETA-LEAFS: excitation wavelength (296.69 nm), noise attenuation and adequate background correction led to a detection limit (3sigma) of 3 ng L(-1) (i.e. 54 pM) for total Fe concentration with the use a 20 microL seawater sample. For the two methods, concentration values obtained for the analysis of Fe in a NASS-5 (0.2 microg L(-1)) seawater sample were in good agreement with the certified values. Copyright 2010 Elsevier B.V. All rights reserved.

  6. Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: A comparative study

    International Nuclear Information System (INIS)

    Cabon, J.Y.; Giamarchi, P.; Le Bihan, A.

    2010-01-01

    Two methods available for direct determination of total Fe in seawater at low concentration level have been examined: electrothermal atomization atomic absorption spectrometry (ETAAS) and electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS). In a first part, we have optimized experimental conditions of ETAAS (electrothermal program, matrix chemical modification) for the determination of Fe in seawater by minimizing the chemical interference effects and the magnitude of the simultaneous background absorption signal. By using the best experimental conditions, a detection limit of 80 ng L -1 (20 μL, 3σ) for total Fe concentration was obtained by ETAAS. Using similar experimental conditions (electrothermal program, chemical modification), we have optimized experimental conditions for the determination of Fe by LEAFS. The selected experimental conditions for ETA-LEAFS: excitation wavelength (296.69 nm), noise attenuation and adequate background correction led to a detection limit (3σ) of 3 ng L -1 (i.e. 54 pM) for total Fe concentration with the use a 20 μL seawater sample. For the two methods, concentration values obtained for the analysis of Fe in a NASS-5 (0.2 μg L -1 ) seawater sample were in good agreement with the certified values.

  7. McDonald Criteria 2010 and 2005 Compared: Persistence of High Oligoclonal Band Prevalence Despite Almost Doubled Diagnostic Sensitivity

    Directory of Open Access Journals (Sweden)

    Philipp Schwenkenbecher

    2016-09-01

    Full Text Available The 2010 McDonald criteria were developed to allow a more rapid diagnosis of relapsing-remitting multiple sclerosis (MS by only one MRI of the brain. Although cerebrospinal fluid (CSF is not a mandatory part of the latest criteria, the evidence of an intrathecal humoral immunoreaction in the form of oligoclonal bands (OCB is crucial in the diagnostic workup. To date, the impact of the 2010 McDonald criteria on the prevalence of OCB has not been investigated. We retrospectively evaluated data of 325 patients with a clinical relapse suggestive of demyelination that were treated in a German university hospital between 2010 and 2015. One hundred thirty-six patients (42% were diagnosed with MS and 189 patients with CIS when the criteria of 2010 were applied. The criteria of 2005 allowed only 70 patients (22% to be designated as MS. In contrast, the prevalence of OCB was marginal affected in MS patients with 96% for the criteria of 2010 and 98.5% for the criteria of 2005. In conclusion, OCB are prevalent in most MS patients and reflect the chronic inflammatory nature of the disease. We recommend CSF examination to exclude alternative diagnoses and reevaluation of the diagnosis MS in patients with negative OCB.

  8. Sensitivity and specificity of narrow-band imaging nasoendoscopy compared to histopathology results in patients with suspected nasopharyngeal carcinoma

    Science.gov (United States)

    Adham, M.; Musa, Z.; Lisnawati; Suryati, I.

    2017-08-01

    Nasopharyngeal carcinoma (NPC) is a disease which is prevalent in developing countries like Indonesia. There were 164 new cases of nasopharyngeal carcinoma in the ear, nose, and throat (ENT) oncology outpatient clinic of the Cipto Mangunkusumo hospital in 2014, and 142 cases in 2015. Unfortunately, almost all of these cases presented at an advanced stage. The success of nasopharyngeal carcinoma treatment is largely determined by the stage when patients are diagnosed; it is critical to diagnose NPC as early as possible. Narrow-band imaging (NBI) is an endoscopic instrument with a light system that can improve the visualization of blood vessels of mucosal epithelial malignant tumors. NBI is expected to help clinicians to assess whether a lesion is malignant or not; to do so, it is important to know the value of sensitivity and specificity. This study is a cross-sectional form of a diagnostic test which was performed in the outpatient clinic of the ENT Head and Neck Surgery Department for the Cipto Mangunkusumo Hospital, from January to June 2016, and involved 56 subjects. Patients with a nasopharyngeal mass discovered by physical examination or imaging, and a suspected nasopharyngeal carcinoma were included as a subject. An NBI examination and biopsy was performed locally. Based on this research, NBI could be used as a screening tool for nasopharyngeal carcinoma with high sensitivity (100%), but with a low specificity result (6.7%).

  9. The effects of low-intensity narrow-band blue-light treatment compared to bright white-light treatment in seasonal affective disorder.

    Science.gov (United States)

    Meesters, Ybe; Duijzer, Wianne B; Hommes, Vanja

    2018-05-01

    Ever since a new photoreceptor was discovered with a highest sensitivity to 470-490 nm blue light, it has been speculated that blue light has some advantages in the treatment of Seasonal Affective Disorder (SAD) over more traditional treatments. In this study we compared the effects of exposure to narrow-band blue light (BLUE) to those of broad-wavelength white light (BLT) in the treatment of SAD. In a 15-day design, 45 patients suffering from SAD completed 30-min sessions of light treatment on 5 consecutive days. 21 subjects received white-light treatment (BLT, broad-wavelength without UV, 10 000 lx, irradiance 31.7 W/m 2 ), 24 subjects received narrow-band blue light (BLUE, 100 lx, irradiance 1.0 W/m 2 ). All participants completed weekly questionnaires concerning mood and energy levels, and were also assessed by means of the SIGH-SAD, which is the primary outcome measure. On day 15, SIGH-SAD ratings were significantly lower than on day 1 (BLT 73.2%, effect size 3.37; BLUE 67%, effect size 2.63), which outcomes were not statistically significant different between both conditions. Small sample size. Light treatment is an effective treatment for SAD. The use of narrow-band blue light is equally effective as a treatment using bright white-light. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Optical absorption of irradiated carbohydrates

    International Nuclear Information System (INIS)

    Supe, A.A.; Tiliks, Yu.E.

    1994-01-01

    The optical absorption spectra of γ-irradiated carbohydrates (glucose, lactose, sucrose, maltose, and starch) and their aqueous solutions were studied. The comparison of the data obtained with the determination of the concentrations of molecular and radical products of radiolysis allows the absorption bands with maxima at 250 and 310 nm to be assigned to the radicals trapped in the irradiated carbohydrates

  11. A pilot comparative study of topical latanoprost and tacrolimus in combination with narrow-band ultraviolet B phototherapy and microneedling for the treatment of nonsegmental vitiligo.

    Science.gov (United States)

    Korobko, Igor V; Lomonosov, Konstantin M

    2016-11-01

    Prostaglandins and their analogues are beneficial as topical agents in vitiligo treatment, yet neither of the previous study addressed their comparative efficiency with conventional topical agents used in vitiligo treatment. In this pilot (24 patients) left-right comparative study we addressed efficiency of prostaglandin F2α analogue latanoprost versus tacrolimus when combined with narrow-band ultraviolet B and microneedling in repigmentation of nonsegmental vitiligo lesions. Our results confirm potency of prostaglandins, in particular, that of latanoprost, in inducing repigmentation, with the efficiency being at least comparable to that of tacrolimus, while contribution of microneedling remains unclear. In summary, results of our study provide further evidences for justified use of prostaglandins, in particular, latanoprost, in vitiligo treatment. In turn, this warrants future studies on the topic aiming to conclusively introduce prostaglandin-based formulations as conventional agents for vitiligo management. © 2016 Wiley Periodicals, Inc.

  12. Passive ranging using a filter-based non-imaging method based on oxygen absorption.

    Science.gov (United States)

    Yu, Hao; Liu, Bingqi; Yan, Zongqun; Zhang, Yu

    2017-10-01

    To solve the problem of poor real-time measurement caused by a hyperspectral imaging system and to simplify the design in passive ranging technology based on oxygen absorption spectrum, a filter-based non-imaging ranging method is proposed. In this method, three bandpass filters are used to obtain the source radiation intensities that are located in the oxygen absorption band near 762 nm and the band's left and right non-absorption shoulders, and a photomultiplier tube is used as the non-imaging sensor of the passive ranging system. Range is estimated by comparing the calculated values of band-average transmission due to oxygen absorption, τ O 2 , against the predicted curve of τ O 2 versus range. The method is tested under short-range conditions. Accuracy of 6.5% is achieved with the designed experimental ranging system at the range of 400 m.

  13. Comparative studies of H absorption/desorption kinetics and evaporation of liquid lithium in different porous systems and free surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Oyarzabal, E., E-mail: eider.oyarzabal@externos.ciemat.es [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); Calle de Guzmán el Bueno, 133, 28003 Madrid (Spain); Martín-Rojo, A.B. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain); Calle de Guzmán el Bueno, 133, 28003 Madrid (Spain); Tabarés, F.L. [Ass. Euratom-Ciemat, Av. Complutense 22, 28040 Madrid (Spain)

    2017-04-15

    In the present work, a study of the two most relevant properties of liquid lithium with respect to its suitability as a Plasma Facing Component (PFC) element in a Reactor, namely, its evaporation rate and the uptake/release of hydrogen, eventually leading to the formation of a stable hydride was carried out for Li in different porous systems and Li as a free surface. These properties were characterized in a temperature range of 200–500 °C. The H{sub 2} absorption kinetics at low pressure (<1torr) were measured for the different studied porous systems and then outgassed. Particle balance and chemical analysis were used to assess the retention properties of lithium for each case. Thermal Desorption Spectroscopy (TDS) analysis was used for the assessment of possible hydride formation. Evaporation rates were determined by using a Quartz Microbalance (QMB). A significant reduction of the evaporation rate was observed when Li was trapped in a microstructure of sintered stainless steel with a characteristic porous size of 5–10 μm. On the other hand, a negligible rate of H{sub 2} uptake was found at temperatures above 500 °C in all cases.

  14. Flow Cytometric DNA index, G-band Karyotyping, and Comparative Genomic Hybridization in Detection of High Hyperdiploidy in Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Larsen, Jacob; Kristensen, Tim D

    2006-01-01

    High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic hybridiza......High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic.......001 for all comparisons). However, in 4 of 18 patients, high hyperdiploidy was overlooked by GBK or HR-CGH, and even when FCM was applied, 2 of 18 patients with high hyperdiploidy by GBK and/or HR-CGH were classified as nonhigh hyperdiploid. If high hyperdiploid subclones were included, FCM could detect all...... high hyperdiploid patients found by either GBK or HR-CGH, but would then in addition classify 15% to 20% of the remaining patients as high hyperdiploid. Thus, both GBK and HR-CGH overlook patients with high hyperdiploidy, and FCM only detects all high hyperdiploid patients if small high hyperdiploid...

  15. A review of studies comparing three laparoscopic procedures in bariatric surgery: sleeve gastrectomy, Roux-en-Y gastric bypass and adjustable gastric banding.

    Science.gov (United States)

    Franco, Juan Victor A; Ruiz, Pablo Adrian; Palermo, Mariano; Gagner, Michel

    2011-09-01

    Obesity is a major worldwide problem in public health, reaching epidemic proportions in many countries, especially in urbanized regions. Bariatric procedures have been shown to be more effective in the management of morbid obesity, compared to medical treatments in terms of weight loss and its sustainability. The two most commonly performed procedures are laparoscopic Roux-en-Y gastric bypass (LRYGB), laparoscopic adjustable gastric banding (LAGB), and the novel laparoscopic sleeve gastrectomy (LSG). The MEDLINE database (cutoff date September 2010), LILACS, and the Cochrane Library were searched using the key words "gastric bypass," "sleeve gastrectomy," and "gastric banding." Only studies that compared at least two of the laparoscopic procedures were included. Reviews and meta-analysis, editorial letters or comments, case reports, animal or in vitro studies, comparisons with medical treatment, comparisons with open (non-laparoscopic) procedures were excluded. Most studies indicated that LRYGB and LSG could be more effective achieving weight loss than LAGB. However, LAGB seems to be a safer procedure with frequent, but less severe, long-term complications. Although not uniformly reported, a resolution of obesity-related comorbidities was achieved with most bariatric procedures. The three procedures have acceptable efficacy and safety. We believe that patients should be informed in detail on the advantages and disadvantages of each available procedure, possibly in several interviews and always accompanied by a specialized interdisciplinary team, warranting long-term follow-up.

  16. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material--an in vitro study.

    Science.gov (United States)

    Dua, R; Nandlal, B

    2004-03-01

    The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.

  17. The effects of low-intensity narrow-band blue-light treatment compared to bright white-light treatment in sub-syndromal seasonal affective disorder.

    Science.gov (United States)

    Meesters, Ybe; Winthorst, Wim H; Duijzer, Wianne B; Hommes, Vanja

    2016-02-18

    The discovery of a novel photoreceptor in the retinal ganglion cells with a highest sensitivity of 470-490 nm blue light has led to research on the effects of short-wavelength light in humans. Several studies have explored the efficacy of monochromatic blue or blue-enriched light in the treatment of SAD. In this study, a comparison has been made between the effects of broad-wavelength light without ultraviolet (UV) wavelengths compared to narrow-band blue light in the treatment of sub-syndromal seasonal affective disorder (Sub-SAD). In a 15-day design, 48 participants suffering from Sub-SAD completed 20-minute sessions of light treatment on five consecutive days. 22 participants were given bright white-light treatment (BLT, broad-wavelength light without UV 10 000 lux, irradiance 31.7 Watt/m(2)) and 26 participants received narrow-band blue light (BLUE, 100 lux, irradiance 1.0 Watt/m(2)). All participants completed daily and weekly questionnaires concerning mood, activation, sleep quality, sleepiness and energy. Also, mood and energy levels were assessed by means of the SIGH-SAD, the primary outcome measure. On day 15, SIGH-SAD ratings were significantly lower than on day 1 (BLT 54.8 %, effect size 1.7 and BLUE 50.7 %, effect size 1.9). No statistically significant differences were found on the main outcome measures. Light treatment is an effective treatment for Sub-SAD. The use of narrow-band blue-light treatment is equally effective as bright white-light treatment. This study was registered in the Dutch Trial Register (Nederlands Trial Register TC =  4342 ) (20-12-2013).

  18. Calcium absorption and achlorhydria

    International Nuclear Information System (INIS)

    Recker, R.R.

    1985-01-01

    Defective absorption of calcium has been thought to exist in patients with achlorhydria. The author compared absorption of calcium in its carbonate form with that in a pH-adjusted citrate form in a group of 11 fasting patients with achlorhydria and in 9 fasting normal subjects. Fractional calcium absorption was measured by a modified double-isotope procedure with 0.25 g of calcium used as the carrier. Mean calcium absorption (+/- S.D.) in the patients with achlorhydria was 0.452 +/- 0.125 for citrate and 0.042 +/- 0.021 for carbonate (P less than 0.0001). Fractional calcium absorption in the normal subjects was 0.243 +/- 0.049 for citrate and 0.225 +/- 0.108 for carbonate (not significant). Absorption of calcium from carbonate in patients with achlorhydria was significantly lower than in the normal subjects and was lower than absorption from citrate in either group; absorption from citrate in those with achlorhydria was significantly higher than in the normal subjects, as well as higher than absorption from carbonate in either group. Administration of calcium carbonate as part of a normal breakfast resulted in completely normal absorption in the achlorhydric subjects. These results indicate that calcium absorption from carbonate is impaired in achlorhydria under fasting conditions. Since achlorhydria is common in older persons, calcium carbonate may not be the ideal dietary supplement

  19. Ultrasonic absorption

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews studies of ultrasonic absorption in liquid alkali metals. The experimental methods to measure the absorption coefficients are briefly described. Experimental results reported for the liquid metals: sodium, potassium, rubidium and caesium, at medium temperatures, are presented, as well as data for liquid alloys. Absorption losses due to the presence of an external magnetic field, and the effects of viscosity on the absorption in metals, are both discussed. (U.K.)

  20. Elastic Properties and the Band Gap of AlNxP1-x Semiconductor Alloy: A Comparative Study of Various Ab Initio Approaches

    Directory of Open Access Journals (Sweden)

    M. P. Polak

    2016-01-01

    Full Text Available Structural and elastic properties of AlNxP1-x, a novel semiconductor alloy, are studied from the first principles in both zinc-blende and wurtzite structures. Performances of the finite difference (FD method and the density functional perturbation theory (DFPT are tested and compared. Both of these methods are applied to two different approaches of alloy simulation, a supercell of 16 and 32 atoms (for zinc-blende and wurtzite structures, resp. and the alchemical mixing (AM method, where the pseudopotentials are mixed in an appropriate way to form an alloy. All elastic properties, including the elastic tensors, elastic moduli, Poisson’s ratio, B/G, and relaxation coefficient, as well as lattice parameters are calculated using all said methods. Conclusions about the use of the approaches investigated in this paper and about their performance are drawn. In addition, in both crystal structures, the band gap is studied in the whole composition range using the MBJLDA functional. The band gap bowings are unusually high, which confirms earlier reports.

  1. Electronic absorption spectra of antiviral aminophenol derivatives

    Science.gov (United States)

    Belkov, M. V.; Ksendzova, G. A.; Raichyonok, T. F.; Skornyakov, I. V.; Sorokin, V. L.; Tolstorozhev, G. B.; Shadyro, O. I.

    2011-03-01

    Electronic absorption spectra of aminophenol derivatives in solutions have been studied. A general property of the absorption spectra of these compounds, the dependence of the maximum of a long-wavelength absorption band on the solvent polarity, is revealed. As a rule, the absorption band maximum of compounds possessing pharmacological properties shows a greater shift to short wavelength with an increase in the medium polarity than that of inactive compounds. Absorption measurements of solutions of aminophenol derivatives can be used for a tentative estimation of their antiviral activity.

  2. Determinação de diagramas de bandas de energia e da borda de absorção em SnO2, depositado via sol-gel, sobre quartzo Determination of the band energy diagram and absorption fundamental edge in SnO2, deposited via sol-gel, on quartz

    Directory of Open Access Journals (Sweden)

    E. A. Floriano

    2009-03-01

    Full Text Available Propriedades ópticas e estruturais de filmes finos de SnO2, depositados sobre substratos de quartzo, são apresentadas. Os filmes são preparados pela técnica de molhamento via sol-gel. Uma avaliação das propriedades eletrônicas do cristal (bulk e das superfícies (110 e (101 do material é também efetuada, através de cálculos baseados em um método mecânico-quântico que utiliza a Teoria do Funcional da Densidade (DFT em conjunto com o funcional hibrido B3LYP. A borda fundamental de absorção, obtida experimentalmente, é então comparada com os diagramas de bandas de energia do bulk e superfícies (110 e (101, calculadas.Optical and structural properties of SnO2 thin films, deposited on quartz substrates, are presented. Films are prepared by the sol-gel-dip-coating technique. An evaluation of the electronic properties of bulk and surfaces (110 and (101 of the material is also carried out, through calculation based on a quantum-mechanical method using the Density Functional Theory (DFT in conjunction with the hybrid functional B3LYP. The absorption fundamental edge, experimentally obtained, is compared to the calculated band energy diagram of bulk and surfaces (110 and (101.

  3. Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study

    Science.gov (United States)

    Chandu, G S; Asnani, Pooja; Gupta, Siddarth; Faisal Khan, Mohd.

    2015-01-01

    Background: Use of alkaline peroxide denture cleanser with different temperature of water could cause a change in surface hardness of the acrylic denture and also has a bleaching effect. The purpose of the study was to determine the effect of increased water content during thermal cycling of hot water-treated acrylic on the surface hardness of acrylic denture base when compared to warm water treated acrylic. And to compare the bleaching effect of alkaline peroxide solution on the acrylic denture base on hot water and warm water treated acrylic. Materials and Methods: Forty samples (10 mm × 10 mm × 2.5 mm) were prepared. After the calculation of the initial hardness 40 samples, each was randomly assigned to two groups. Group A: 20 samples were immersed in 250 ml of warm distilled water at 40°C with alkaline peroxide tablet. Group B: 20 samples were immersed in 250 ml of hot distilled water at 100°C with alkaline peroxide tablet. The surface hardness of each test sample was obtained using the digital hardness testing machine recording the Rockwell hardness number before the beginning of the soaking cycles and after completion of 30 soak cycles and compared. Values were analyzed using paired t-test. Five samples from the Group A and five samples from Group B were put side by side and photographed using a Nikon D 40 digital SLR Camera and the photographs were examined visually to assess the change in color. Results: Acrylic samples immersed in hot water showed a statistically significant decrease of 5.8% in surface hardness. And those immersed in warm water showed a statistically insignificant increase of 0.67% in surface hardness. Samples from the two groups showed clinically insignificant difference in color when compared to each other on examination of the photographs. Conclusion: Thermocycling of the acrylic resin at different water bath temperature at 40°C and 100°C showed significant changes in the surface hardness. PMID:25954074

  4. Comparing Various Type of Natural Fibers as Filler in TPU: Mechanical Properties, Morphological and Oil Absorption Behavior

    Directory of Open Access Journals (Sweden)

    Ahad Nor Azwin

    2017-01-01

    Full Text Available The idea of using natural fibers as filler in various polymers has been extensively studied. Various types of natural fibers and polymers have been identified and it can be varied according to the particular application and the two main composite materials will have advantages and disadvantages of each. However, natural fibers are usually selected as filler because it is readily available and environmentally friendly, inexpensive, non-toxic, biodegradable and still have good characteristics for a variety of uses. In this study, four types of natural fiber have been used which; coconut shell, coconut fiber, corn cob, and pineapple skin, as fillers in thermoplastic polyurethane (TPU. The mixing process conducted through melt mixing techniques. The percentage of TPU and natural fibers are 100/0, 95/5, 90/10 and 85/15. Different type of fiber will affect the mechanical properties of the composites and have been studied through tensile testing. It showed that the result for pineapple fiber at 5% was the highest and can also be related to the characterizations of this composite that have been studied via the SEM morphology. Swelling testing is also having been done to prove the absorbency ability by natural fiber composites in cooking oil and engine oil. Then it concluded that the pineapple fiber absorbed large amount of both oil compared to others.

  5. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due

  6. Absorption studies

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  7. Effect of Al doping on microstructure and optical band gap of ZnO ...

    Indian Academy of Sciences (India)

    % AZO indicating a blue-shift for 1% AZO film. However, for 2% AZO film, a decrease in band gap compared to pure ZnO is observed indicating a red-shift of fundamental absorption edge. Electrical resistance shows an initial decrease with.

  8. Increased postprandial energy expenditure may explain superior long term weight loss after Roux-en-Y gastric bypass compared to vertical banded gastroplasty.

    Directory of Open Access Journals (Sweden)

    Malin Werling

    Full Text Available BACKGROUND AND AIMS: Gastric bypass results in greater weight loss than Vertical banded gastroplasty (VBG, but the underlying mechanisms remain unclear. In addition to effects on energy intake the two bariatric techniques may differentially influence energy expenditure (EE. Gastric bypass in rats increases postprandial EE enough to result in elevated EE over 24 hours. This study aimed to investigate alterations in postprandial EE after gastric bypass and VBG in humans. METHODS: Fourteen women from a randomized clinical trial between gastric bypass (n = 7 and VBG (n = 7 were included. Nine years postoperatively and at weight stability patients were assessed for body composition and calorie intake. EE was measured using indirect calorimetry in a respiratory chamber over 24 hours and focused on the periods surrounding meals and sleep. Blood samples were analysed for postprandial gut hormone responses. RESULTS: Groups did not differ regarding body composition or food intake either preoperatively or at study visit. Gastric bypass patients had higher EE postprandially (p = 0.018 and over 24 hours (p = 0.048 compared to VBG patients. Postprandial peptide YY (PYY and glucagon like peptide 1 (GLP-1 levels were higher after gastric bypass (both p<0.001. CONCLUSIONS: Gastric bypass patients have greater meal induced EE and total 24 hours EE compared to VBG patients when assessed 9 years postoperatively. Postprandial satiety gut hormone responses were exaggerated after gastric bypass compared to VBG. Long-term weight loss maintenance may require significant changes in several physiological mechanisms which will be important to understand if non-surgical approaches are to mimic the effects of bariatric surgery.

  9. Terahertz Absorption Spectroscopy of Benzamide, Acrylamide, Caprolactam, Salicylamide, and Sulfanilamide in the Solid State

    Directory of Open Access Journals (Sweden)

    Ye Jiang

    2014-01-01

    Full Text Available Terahertz (THz absorption spectra of the similarly structured molecules with amide groups including benzamide, acrylamide, caprolactam, salicylamide, and sulfanilamide in the solid phase at room temperature and 7.8 K for salicylamide are reported and compared to infrared vibrational spectral calculations using density functional theory. The results of THz absorption spectra show that the molecules have characteristic bands in the region of 0.2–2.6 THz (~7–87 cm−1. THz technique can be used to distinguish different molecules with amide groups. In the THz region benzamide has three bands at 0.83, 1.63, and 1.73 THz; the bands are located at 1.44 and 2.00 THz for acrylamide; the bands at 1.24, 1.66 and 2.12 THz are observed for caprolactam. The absorption bands are located at 1.44, 1.63, and 2.39 THz at room temperature, and at 1.22, 1.46, 1.66, and 2.41 THz at low temperature for salicylamide. The bands at 1.63, 1.78, 2.00, and 2.20 THz appear for sulfanilamide. These bands in the THz region may be related to torsion, rocking, wagging, and other modes of different groups in the molecules.

  10. Photoionization bands of rubidium molecule

    Science.gov (United States)

    Rakić, M.; Pichler, G.

    2018-03-01

    We studied the absorption spectrum of dense rubidium vapor generated in a T-type sapphire cell with a special emphasis on the structured photoionization continuum observed in the 200-300 nm spectral region. The photoionization spectrum has a continuous atomic contribution with a pronounced Seaton-Cooper minimum at about 250 nm and a molecular photoionization contribution with many broad bands. We discuss the possible origin of the photoionization bands as stemming from the absorption from the ground state of the Rb2 molecule to excited states of Rb2+* and to doubly excited autoionizing states of Rb2** molecule. All these photoionization bands are located above the Rb+ and Rb2+ ionization limits.

  11. Folate absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  12. Narrative absorption

    DEFF Research Database (Denmark)

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. Nor...... do we fully realize how we might have changed as we return for the fictional worlds we have visited. The feeling of being absorbed is one of the most illusive and transient feelings, but also one that motivates audiences to spend considerable amounts of time in narrative worlds, and one...... that is central to our understanding of the effects of narratives on beliefs and behavior. Key specialists inform the reader of this book about the nature of the peculiar state of consciousness during episodes of absorption, the perception of absorption in history, the role of absorption in meaningful experiences...

  13. Absorption by DNA single strands of adenine isolated in vacuo: The role of multiple chromophores

    DEFF Research Database (Denmark)

    Nielsen, L.M.; Pedersen, S.O.; Kirketerp, M.-B.S.

    2012-01-01

    to that for the adenine molecule and the dAMP mononucleotide. Desolvation has little effect on the bandwidth, which implies that inhomogenous broadening of the absorption bands in aqueous solution is of minor importance compared to, e.g., conformational disorder. Finally, at high photon energies, internal conversion...

  14. Uranium absorption study pile

    International Nuclear Information System (INIS)

    Raievski, V.; Sautiez, B.

    1959-01-01

    The report describes a pile designed to measure the absorption of fuel slugs. The pile is of graphite and comprises a central section composed of uranium rods in a regular lattice. RaBe sources and BF 3 counters are situated on either side of the center. A given uranium charge is compared with a specimen charge of about 560 kg, and the difference in absorption between the two noted. The sensitivity of the equipment will detect absorption variations of about a few ppm boron (10 -6 boron per gr. of uranium) or better. (author) [fr

  15. Spectral absorption shifts in CuCl vs pressure to 147 kbar

    International Nuclear Information System (INIS)

    Liebenberg, D.H.; Hudson, J.

    1981-02-01

    Measurements of the absorption of CuCl in the spectral region 200 to 800 nm are reported as a function of pressure to 147 kbar. In this region, phase transitions are identified with the abrupt changes of the absorption cutoff, the pressure dependence of the cutoff is determined, and a log-linear response is found for the absorption with photon energy. The measurements are compared with recent published data and indicate a new anomaly for the band gap in our sample at high pressures

  16. Observing broad-absorption line quasars with Spectrum-Rontgen-Gamma

    DEFF Research Database (Denmark)

    Singh, K.P.; Schnopper, H.W.; Westergaard, Niels Jørgen Stenfeldt

    1998-01-01

    Broad-absorption line quasars are found to have extremely weak soft X-ray emission when compared with other optically selected quasars. In the only example of PHL 5200 for which a detailed X-ray spectrum has been obtained with ASCA, strong absorption in the source appears to be responsible...... for the lack of soft Xray emission. Broad-band X-ray observations of a sample of BAL QSOs are proposed with a high throughput mission SPECTRUM-RONTGEN-GAMMA (SRG), to find out whether these sources are intrinsically weak over the entire bandwidth of X-rays or only in the soft X-rays due to absorption resulting...

  17. Ultraviolet absorption detection of DNA in gels

    International Nuclear Information System (INIS)

    Mahon, A.R.

    1998-01-01

    A method and apparatus for the detection and quantification of large fragments of unlabelled deoxyribonucleic acid (DNA) in agarose gels is presented. The technique is based on ultra-violet (UV) absorption by nucleotides. A deuterium lamp was used to illuminate regions of an electrophoresis gel. As DNA bands passed through the illuminated region of the gel the amount of UV light transmitted was reduced due to DNA absorption. Two detection systems were investigated. In the first system, synthetic chemical vapour deposition (CVD) diamond strip detectors were used to locate regions of DNA in the gels by detecting the transmitted light. CVD diamond has a high indirect band gap of 5.45 eV and is therefore sensitive to UV photons of wavelengths < 224 nm. A number of CVD diamond samples were characterised to investigate their suitability as detectors for this application. The detectors' quantum efficiency, UV response and time response were measured. DNA bands containing as little as 20 ng were detected by the diamond. In a second system, a deuterium lamp was used to illuminate individual sample lanes of an electrophoresis gel via an array of optical fibres. During electrophoresis the regions of DNA were detected with illumination at 260 nm, using a UV-sensitive charge coupled device (CCD). As the absorption coefficient of a DNA sample is approximately proportional to its mass, the technique is inherently quantitative. This system had a detection limit of 0.25 ng compared with 2-10 ng for the most popular conventional technique, ethidium bromide (EtBr) staining. Using this detection technique, the DNA sample remains in its native state. The removal of carcinogenic dyes from the detection procedure greatly reduces associated biological hazards. (author)

  18. Serum lipidomics reveals early differential effects of gastric bypass compared with banding on phospholipids and sphingolipids independent of differences in weight loss.

    Science.gov (United States)

    Kayser, B D; Lhomme, M; Dao, M C; Ichou, F; Bouillot, J-L; Prifti, E; Kontush, A; Chevallier, J-M; Aron-Wisnewsky, J; Dugail, I; Clément, K

    2017-06-01

    Circulating phospholipids and sphingolipids are implicated in obesity-related comorbidities such as insulin resistance and cardiovascular disease. How bariatric surgery affects these important lipid markers is poorly understood. We sought to determine whether Roux-en-Y gastric bypass (RYGB), which is associated with greater metabolic improvement, differentially affects the phosphosphingolipidome compared with adjustable gastric banding (AGB). Fasting sera were available from 59 obese women (body mass index range 37-51 kg m -2 ; n=37 RYGB and 22 AGB) before surgery, then at 1 (21 RYGB, 12 AGB) and 3 months follow-up (19 RYGB, 12 AGB). HPLC-MS/MS was used to quantify 131 lipids from nine structural classes. DXA measurements and laboratory parameters were also obtained. The associations between lipids and clinical measurements were studied with P-values adjusted for the false discovery rate (FDR). Both surgical procedures rapidly induced weight loss and improved clinical profiles, with RYGB producing better improvements in fat mass, and serum total cholesterol, low-density lipoprotein-cholesterol (LDL-C) and orosomucoid (FDR RYGB during the study period. The differential effect of the surgeries remained statistically significant for 20 of these lipids after adjusting for differences in weight loss between surgery types. The RYGB signature consisted of phosphatidylcholine species not exceeding 36 carbons, and ceramides and sphingomyelins containing C22 to C25 fatty acids. RYGB also led to a sustained increase in unsaturated ceramide and sphingomyelin species. The RYGB-specific lipid changes were associated with decreases in body weight, total and LDL-C, orosomucoid and increased HOMA-S (FDR RYGB induced early and sustained changes in phosphatidylcholines, sphingomyelins and ceramides that were independent of greater weight loss. These data suggest that RYGB may specifically alter sphingolipid metabolism, which, in part, could explain the better metabolic

  19. UV Absorption Measurements of Nitric Oxide Compared to Probe Sampling Data for Measurements in a Turbine Engine Exhaust at Simulated Altitude Conditions

    National Research Council Canada - National Science Library

    Howard, R

    1997-01-01

    .... NO-UV absorption measurements, using both resonance and continuum lamps, were made through several chords of the exhaust flow near the nozzle exit plane as a part of a larger effort to characterize...

  20. Regularity of the interband light absorption coefficient

    Indian Academy of Sciences (India)

    In experimental studies the absorption coefficient is a means to study the band gaps at ... to l2( ), where. ⊂ Zd is a finite set. (usually taken to be a lattice cube centred at the origin) and λ±,uλ± are eigenvalues and eigenfunctions of H. ±. ,ω . Then the interband light absorption coefficient A for such finite volume models can.

  1. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho

    2009-01-01

    Background Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. Objective The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. Methods A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm2. We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. Results For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm2 range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. Conclusion A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross

  2. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB.

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho; Kim, Young-Hun

    2009-05-01

    Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm(2). We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm(2) range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is

  3. A comparative study of calcium absorption following a single serving administration of calcium carbonate powder versus calcium citrate tablets in healthy premenopausal women

    Directory of Open Access Journals (Sweden)

    Haiyuan Wang

    2014-04-01

    Full Text Available Background: Calcium is an essential mineral often taken as a daily, long-term nutritional supplement. Data suggests that once-daily dosing is important with regard to long-term compliance of both drugs and nutritional supplements. Objective: This study was undertaken to compare the bioavailability of a single serving of two calcium supplements in healthy, premenopausal women. Design: A two-period, crossover bioavailability study of a single serving of calcium citrate tablets (two tablets=500 mg calcium versus a single serving of calcium carbonate powder (one packet of powder=1,000 mg calcium was performed in healthy women aged between 25 and 45. All subjects were on a calcium-restricted diet 7 days prior to testing and fasted for 12 h before being evaluated at 0, 1, 2, and 4 h after oral administration of the test agents. Blood measurements for total and ionized calcium and parathyroid hormone were performed and adverse events were monitored. Results: Twenty-three women were evaluable with a mean age of 33.2±8.71. Results showed that administration of a single serving of a calcium carbonate powder resulted in greater absorption in total and ionized calcium versus a single serving of calcium citrate tablets at 4 h (4.25±0.21 vs. 4.16±0.16, p=0.001. There were minimal side effects and no reported serious adverse events. Conclusions: This study shows that a single serving of a calcium carbonate powder is more bioavailable than a single serving of calcium citrate tablets. This may be beneficial for long-term compliance.

  4. Optical absorption in irradiated natural beryl

    International Nuclear Information System (INIS)

    Isotani, S.; Dias, O.L.; Albuquerque, A.R.P.L.

    1983-10-01

    Three species of beryl irradiated with γ-rays of 60 Co were studied by optical absorption. One became yellow and the other two Maxixe's blue. The effects of heat treatments were determined by the thermal isochronal decays of the optical absorption bands. Activation energies and frequency factor were obtained through the first order process kinetic model. Discussions lend us to assign for the UV band-edge the model of absorption by a hole center stabilized by a Fe 2+ (substituting Al 3+ ) ion in a neighbour oxygen. (Author) [pt

  5. Safety Evaluation of Laparoscopic Sleeve Gastrectomy Compared with Two Procedures of Laparoscopic Roux-en-Y Gastric Bypass and Laparoscopic Adjustable Gastric Banding for Individuals with Morbid Obesity: A Systemic Review

    OpenAIRE

    F Arabi Basharic; A Olyaee Manesh; M Ranjbar Ezzatabadi; R Goudarzi; SM Shiryazdi; M Arab zozani; MR Mobini Zade

    2015-01-01

    Introduction: Laparoscopic Roux-en-Y gastric bypass and laparoscopic adjustable gastric banding are the most common bariatric surgery procedures. Therefore, this study aims to compare the safety of the newer procedure of Laparoscopic sleeve gastrectomy compared to Laparoscopic Roux-en-Y gastric bypass and Laparoscopic adjustable gastric bonding. Method: A systematic review was conducted on the most important and most relevant search data bases, including Cochrane library, Pubmed, Ovid Med...

  6. Microwave absorption properties of planar-anisotropy Ce{sub 2}Fe{sub 17}N{sub 3−δ} powders/Silicone composite in X-band

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Xisheng [Research Center of Magnetic and Electronic Materials, College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou 310000 (China); Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Tan, Guoguo; Chen, Shuwen [Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Man, Qikui, E-mail: Manqk@nimte.ac.cn [Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Chang, Chuntao; Wang, Xinmin; Li, Run-Wei [Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201 (China); Che, Shenglei, E-mail: Cheshenglei@zjut.edu.cn [Research Center of Magnetic and Electronic Materials, College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou 310000 (China); and others

    2017-02-15

    The soft-magnetic properties of planar-anisotropy Ce{sub 2}Fe{sub 17}N{sub 3-δ} powders were reported, and reflection loss (RL) of the powders/Silicone composites with various volume concentrations have been studied in 0.1–18 GHz frequency range. It was found that the optimal RL of this composite absorber with a thickness of 1.72 mm is −60.5 dB at 9.97 GHz and the RL is less than −10 dB in the whole X-band (8–12 GHz). The bandwidth with RL exceeding −10 dB and −20 dB are 5.24 GHz and 1.32 GHz, respectively. Furthermore, all the optimal RL value of the composite with the thickness less than 2.13 mm can reach −20 dB in the range of 8–17 GHz, which indicates that the Ce{sub 2}Fe{sub 17}N{sub 3-δ}/Silicone composite absorber will be a promising candidate in higher gigahertz frequency especially in X-band. - Highlights: • The high quality Ce{sub 2}Fe{sub 17}N{sub 3−δ} powders was prepared. • The microwave magnetic properties were reported for the soft Ce{sub 2}Fe{sub 17}N{sub 3−δ} powders. • Ce{sub 2}Fe{sub 17}N{sub 3−δ} composite exhibits relative high permeability over GHz frequency range. • Ce{sub 2}Fe{sub 17}N{sub 3−δ} composite can be an excellent candidate as the absorber in X-band.

  7. Absorption and Scattering by Molecules and Particles

    Science.gov (United States)

    Lenoble, Jacqueline; Mishchenko, Michael I.; Herman, Maurice

    2013-01-01

    The Earth's atmosphere absorbs, scatters, and emits electromagnetic radiation. Although air molecules are the primary actors in these processes, aerosol particles are also present ubiquitously and modify the radiation field. In fact, this modification constitutes the very physical basis of aerosol remote sensing. Whenever clouds are present, they have a much larger influence on radiation which largely overshadows the aerosol impact. Therefore, in aerosol remote sensing, one often has to limit observations to cloudless conditions and screen cloudy pixels. In the solar part of the spectrum, molecular absorption is mostly limited to ultraviolet (UV; ozone) and near-infrared (near-IR; carbon dioxide, water vapor) wavelengths and is characterized by strong and narrow oxygen bands. A brief description of atmospheric molecular absorption is presented in Section 2.2. Shortwave aerosol remote sensing is usually performed outside the absorption bands, but some instruments also have channels capturing absorption bands with the objective of quantifying gaseous components.

  8. On pair-absorption in intrinsic vapours

    International Nuclear Information System (INIS)

    Hotop, R.; Niemax, K.; Schlueter, D.

    1982-01-01

    The bound-state pair-absorption bands Cs(6 2 S 1 sub(/) 2 ) + Cs(6 2 S 1 sub(/) 2 ) + hν → Cs(5 2 D 5 sub(/) 2 sub(,) 3 sub(/) 2 ) + Cs(6 2 P 1 sub(/) 2 ) and the K-K continuum-state pair-absorptions in the wavelength region 2.350 <= lambda <= 2.850 Angstroem have been investigated experimentally. In the case of the bound-state pair-absorption bands a theoretical approach for the absorption cross section at the band centre is given which is in good agreement with the experimental observation. Differences between our and the theoretical formulas given by the Stanford group are discussed. (orig.)

  9. Donor impurity-related optical absorption spectra in GaAs-Ga{sub 1-x}Al{sub x}As quantum wells: hydrostatic pressure and {gamma}-X conduction band mixing effects

    Energy Technology Data Exchange (ETDEWEB)

    Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, C.P. 62209, Cuernavaca, MOR (Mexico); Inst. de Ciencia de Materiales de Madrid, CSIC, Sor Juana Ines de la Cruz 3, 28049 Madrid (Spain); Lopez, S.Y. [Fac. de Educacion, Universidad de Antioquia, AA 1226, Medellin (Colombia); Duque, C.A. [Inst. de Fisica, Universidad de Antioquia, AA 1226, Medellin (Colombia); Velasco, V.R. [Inst. de Ciencia de Materiales de Madrid, CSIC, Sor Juana Ines de la Cruz 3, 28049 Madrid (Spain)

    2007-07-01

    Using a variational procedure within the effective mass approximation, the mixing between the {gamma} and X conduction band valleys in GaAs-Ga{sub 1-x}Al{sub x}As quantum wells is investigated by taking into account the effect of applied hydrostatic pressure. Some optical properties such as donor and/or acceptor binding energy and impurity-related transition energies are calculated and comparisons with available experimental data are presented. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Absorption by water vapour in the 1 to 2 μm region

    International Nuclear Information System (INIS)

    Smith, K.M.; Ptashnik, I.; Newnham, D.A.; Shine, K.P.

    2004-01-01

    The near-IR (in the range 5000-10 000 cm -1 , 1-2 μm) bands of water vapour have been measured in absorption in the laboratory at sub-Doppler spectral resolution (up to 0.0054 cm -1 after numerical apodisation) by Fourier transform spectroscopy. Measurements have been made at 296 K on pure water vapour (at pressures between 2 and 20 hPa) and mixtures of water and air (at total pressures of 100 and 1000 hPa), at optical path lengths in the range 0.26-9.75 m. Measured absorption intensities have been compared with values calculated using the HITRAN 2000 molecular database. These comparisons indicate that the intensities of the 2ν(1.4 μm) and 2ν+δ(1.14 μm) bands are underestimated in HITRAN 2000 by approximately 15% and 20%, respectively, for pure water vapour measurements, and 12% for both bands in the case of water-air mixtures. The ν+δ (1.86 μm) band is in good agreement (0.4% for pure water vapour and less than 6% for mixtures with air) with HITRAN 2000. For typical atmospheric conditions, these absorption bands are sufficiently strong that radiation is fully absorbed at wavelengths in the region of the band centres. Hence the extra absorption that has been identified has only a modest impact (0.16 W m -2 or about 0.2%) on the global-mean clear-sky absorption of solar radiation. The impact in the upper troposphere is several times larger

  11. Quantitative mineral salt evaluation in the calcaneous bone using computed tomography, 125I-photon absorption and chemical analysis to compare the value of the individual methods

    International Nuclear Information System (INIS)

    Hitzler, H.J.

    1983-01-01

    It was the aim of the study described here to verify the accuracy of two different methods for the quantitative evaluation of mineral salts, which were the 125I-photon absorption technique on the one hand and wholebody CT on the other hand. For this purpose, post-mortem examinations of 31 calcaneous bones were carried out to evaluate their individual mineral salt contents in vitro using either of the above-mentioned methods. The results obtained were subsequently contrasted with calcium concentrations determined by chemical analysis. A comparison of the individual mineral salt evaluations with the results from calcium analyses pointed to a highly significant correlation (p=0.001) for both methods under investigation. The same held for the correlation of findings from CT and the 125I-hydroxylapatite technique, where the level of significance was also p=0.001. The above statements must, however, be modified in as much as the mineral salt values measured by CT were consistently lower than those obtained on the basis of 125I-photon absorption. These deviations are chiefly attributable to the fact that the values provided by CT are more susceptible to influences from the fat contained in the bones. In 125I-photon absorption a special formula may be derived to allow for the bias occurring here, provided that the composition of the bone is known. To summarise, the relative advantages and drawbacks of CT and 125I-photon absorption are carefully balanced. Mineral salt evaluations by CT permit incipient losses to be ascertained even in the trunk. The 125I-photon absorption technique would appear to be the obvious method for any kind of follow-up examination in the peripheral skeleton, as it is easily reproducible and radiation exposure can be kept to minimum. (TRV) [de

  12. An Accurate Method for Computing the Absorption of Solar Radiation by Water Vapor

    Science.gov (United States)

    Chou, M. D.

    1980-01-01

    The method is based upon molecular line parameters and makes use of a far wing scaling approximation and k distribution approach previously applied to the computation of the infrared cooling rate due to water vapor. Taking into account the wave number dependence of the incident solar flux, the solar heating rate is computed for the entire water vapor spectrum and for individual absorption bands. The accuracy of the method is tested against line by line calculations. The method introduces a maximum error of 0.06 C/day. The method has the additional advantage over previous methods in that it can be applied to any portion of the spectral region containing the water vapor bands. The integrated absorptances and line intensities computed from the molecular line parameters were compared with laboratory measurements. The comparison reveals that, among the three different sources, absorptance is the largest for the laboratory measurements.

  13. Demonstration That Calibration of the Instrument Response to Polarizations Parallel and Perpendicular to the Object Space Projected Slit of an Imaging Spectrometer Enable Measurement of the Atmospheric Absorption Spectrum in Region of the Weak CO2 Band for the Case of Arbitrary Polarization: Implication for the Geocarb Mission

    Science.gov (United States)

    Kumer, J. B.; Rairden, R. L.; Polonsky, I. N.; O'Brien, D. M.

    2014-12-01

    The Tropospheric Infrared Mapping Spectrometer (TIMS) unit rebuilt to operate in a narrow spectral region, approximately 1603 to 1615 nm, of the weak CO2 band as described by Kumer et al. (2013, Proc. SPIE 8867, doi:10.1117/12.2022668) was used to conduct the demonstration. An integrating sphere (IS), linear polarizers and quarter wave plate were used to confirm that the instrument's spectral response to unpolarized light, to 45° linearly polarized light and to circular polarized light are identical. In all these cases the intensity components Ip = Is where Ip is the component parallel to the object space projected slit and Is is perpendicular to the slit. In the circular polarized case Ip = Is in the time averaged sense. The polarizer and IS were used to characterize the ratio Rθ of the instrument response to linearly polarized light at the angle θ relative to parallel from the slit, for increments of θ from 0 to 90°, to that of the unpolarized case. Spectra of diffusely reflected sunlight passed through the polarizer in increments of θ, and divided by the respective Rθ showed identical results, within the noise limit, for solar spectrum multiplied by the atmospheric transmission and convolved by the Instrument Line Shape (ILS). These measurements demonstrate that unknown polarization in the diffusely reflected sunlight on this small spectral range affect only the slow change across the narrow band in spectral response relative to that of unpolarized light and NOT the finely structured / high contrast spectral structure of the CO2 atmospheric absorption that is used to retrieve the atmospheric content of CO2. The latter is one of the geoCARB mission objectives (Kumer et al, 2013). The situation is similar for the other three narrow geoCARB bands; O2 A band 757.9 to 768.6 nm; strong CO2 band 2045.0 to 2085.0 nm; CH4 and CO region 2300.6 to 2345.6 nm. Polonsky et al have repeated the mission simulation study doi:10.5194/amt-7-959-2014 assuming no use of a geo

  14. Absorption and emission spectroscopic characterisation of 8-amino-riboflavin

    International Nuclear Information System (INIS)

    Tyagi, A.; Zirak, P.; Penzkofer, A.; Mathes, T.; Hegemann, P.; Mack, M.; Ghisla, S.

    2009-01-01

    The flavin dye 8-amino-8-demethyl-D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.

  15. Absorption and emission spectroscopic characterisation of 8-amino-riboflavin

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, A.; Zirak, P. [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Penzkofer, A., E-mail: alfons.penzkofer@physik.uni-regensburg.de [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Mathes, T.; Hegemann, P. [Institut fuer Biologie/Experimentelle Biophysik, Humboldt Universitaet zu Berlin, Invalidenstrasse 42, D-10115 Berlin (Germany); Mack, M. [Institut fuer Technische Mikrobiologie, Hochschule Mannheim, Paul-Wittsack-Str. 10, D-68163 Mannheim (Germany); Ghisla, S. [Universitaet Konstanz, Fakultaet fuer Biologie, P.O. Box 5560-M644, D-78457 Konstanz (Germany)

    2009-10-16

    The flavin dye 8-amino-8-demethyl-D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.

  16. Magneto-absorption in Narrow Gap InSb/AlInSb Parabolic Quantum Wells

    Science.gov (United States)

    Saha, D.; Sanders, G. D.; Stanton, C. J.; Kasturiarachchi, T.; Gempel, W.; Edirisooriya, M.; Mishima, T. D.; Doezema, R. E.; Santos, M. B.

    2010-03-01

    Because of its narrow gap, InSb has considerable promise as a quantum well material because its small conduction-band mass gives it the highest room temperature electron mobility among the III-V materials. We present experiments and calculations for the magneto-absorption spectra in a strained, narrow gap InSb/AlInSb parabolic quantum well. Our calculations are based on the 8-band Pidgeon-Brown model generalized to include the effects of the parabolic confinement potential as well as pseudomorphic strain. Optical properties are calculated within the golden rule approximation and compared with experiments. The magneto-optical absorption spectrum is calculated for magnetic fields from 1 to 8 T for x-linear, e-active and h-active polarizations. Comparison to experiment allows one to accurately determine the quantum confined, spin-split conduction and valence band energies. Results show a sensitive dependence on the strain at the pseudomorphic interfaces.

  17. The effect of dimethylsulfoxide on absorption and fluorescence spectra of aqueous solutions of acridine orange base.

    Science.gov (United States)

    Markarian, Shiraz A; Shahinyan, Gohar A

    2015-12-05

    The photophysical properties of aqueous solutions of acridine orange base (AOB) in wide concentration range of dimethylsulfoxide (DMSO) were studied by using absorption and steady-state fluorescence spectroscopy techniques at room temperature. The absorption spectrum of acridine orange in water shows two bands at 468 and 490 nm which were attributed to the dimer ((AOBH)2(2+)) and monomer (AOBH(+)) species respectively. In DMSO solution for the same AOB concentration only the basic form was detected with the band at 428 nm. The addition of DMSO to AOB aqueous solution leads to the decrease of absorption band at 490 nm and the new absorption band increases at 428 nm due to deprotonated (basic) form of AO and the first isosbestic point occurs at 450 nm. The evolution of isosbestic point reveals that an other equilibrium, due to the self-association of DMSO molecules takes place. From the steady-state fluorescence spectra Stokes shifts were calculated for AOB in aqueous and DMSO solutions. The addition of DMSO into the aqueous solution induced the enhancement in the fluorescence intensity of the dye compared to those in water. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Comparative measurements of mineral salt concentrations in the calcaneus by 125I γ-absorption measurement in the course of fractures of the lower extremities

    International Nuclear Information System (INIS)

    Mehrlich, P.

    1979-01-01

    In a group of 52 patients aged between 16 and 78 years, all with fractures of the lower extremities, BMC concentrations were determined in a period from 10 weeks to 50 month after the accident in both calcaneal bones and the right ulna. The gamma absorption measurements were carried out in a single-isotope technique in a water bath, using a 125 I source as radionuclides. The results were evaluated by planimetrisation of the absorption curve. The patients were divided in groups according to clinically complicated, clinically uncomplicated, radiologically demineralized, and radiologically and clinically uncomplicated healing. In 11 patients, up to 4 measurements were also carried out as course control measures. The results differed in dependence of the patients' age. The localisation of the fracture had no effect on the degree of demineralisation. (orig./MG) [de

  19. Comparative measurements of mineral salt concentrations in the calcaneus by /sup 125/I. gamma. -absorption measurement in the course of fractures of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Mehrlich, P.

    1979-01-01

    In a group of 52 patients aged between 16 and 78 years, all with fractures of the lower extremities, BMC concentrations were determined in a period from 10 weeks to 50 month after the accident in both calcaneal bones and the right ulna. The gamma absorption measurements were carried out in a single-isotope technique in a water bath, using a /sup 125/I source as radionuclides. The results were evaluated by planimetrisation of the absorption curve. The patients were divided in groups according to clinically complicated, clinically uncomplicated, radiologically demineralized, and radiologically and clinically uncomplicated healing. In 11 patients, up to 4 measurements were also carried out as course control measures. The results differed in dependence of the patients' age. The localisation of the fracture had no effect on the degree of demineralisation.

  20. Children's phthalate intakes and resultant cumulative exposures estimated from urine compared with estimates from dust ingestion, inhalation and dermal absorption in their homes and daycare centers

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Weschler, Charles J.; Langer, Sarka

    2013-01-01

    (median: 4.42 µg/d/kg-bw) and BBzP the lowest (median: 0.49 µg/d/kg-bw). For DEP, DnBP and DiBP, exposures to air and dust in the indoor environment accounted for approximately 100%, 15% and 50% of the total intake, respectively, with dermal absorption from the gas-phase being the major exposure pathway...

  1. High-resolution continuum source graphite furnace molecular absorption spectrometry compared with ion chromatography for quantitative determination of dissolved fluoride in river water samples.

    Science.gov (United States)

    Ley, Philip; Sturm, Manfred; Ternes, Thomas A; Meermann, Björn

    2017-12-01

    In addition to beneficial health effects, fluoride can also have adverse effects on humans, animals, and plants if the daily intake is strongly elevated. One main source of fluoride uptake is water, and thus several ordinances exist in Germany that declare permissible concentrations of fluoride in, for example, drinking water, mineral water, and landfill seepage water. Controlling the fluoride concentrations in aqueous matrices necessitate valid and fast analytical methods. In this work an alternative method for the determination of fluoride in surface waters based on high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) was applied. Fluoride detection was made possible by the formation of a diatomic molecule, GaF, and detection of characteristic molecular absorption. On HR-CS-GFMAS parameter optimization, the method was adapted to surface water sample analysis. The influence of potential main matrix constituents such as Na + , Ca 2+ , Mg 2+ , and Cl - as well as surface water sampling/storage conditions on the molecular absorption signal of GaF was investigated. Method validation demonstrated a low limit of detection (8.1 μg L -1 ) and a low limit of quantification (26.9 μg L -1 ), both sufficient for direct river water sample analysis after 0.45-μm filtration. The optimized HR-CS-GFMAS method was applied for the analysis of real water samples from the rivers Rhine and Moselle. For method validation, samples were also analyzed by an ion chromatography (IC) method. IC and HR-CS-GFMAS results both agreed well. In comparison with IC, HR-CS-GFMAS has higher sample throughput, a lower limit of detection and a lower limit of quantification, and higher selectivity, and is a very suitable method for the analysis of dissolved fluoride in river water. Graphical abstract High-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) was applied for the quantitative analysis of dissolved

  2. Sensitization of Perovskite Strontium Stannate SrSnO3 towards Visible-Light Absorption by Doping

    Directory of Open Access Journals (Sweden)

    Hungru Chen

    2014-01-01

    Full Text Available Perovskite strontium stannate SrSnO3 is a promising photocatalyst. However, its band gap is too large for efficient solar energy conversion. In order to sensitize SrSnO3 toward visible-light activities, the effects of doping with various selected cations and anions are investigated by using hybrid density functional calculations. Results show that doping can result in dopant level to conduction band transitions which lie lower in energy compared to the original band gap transition. Therefore, it is expected that doping SrSnO3 can induce visible-light absorption.

  3. Effect of band gap engineering in anionic-doped TiO2 photocatalyst

    International Nuclear Information System (INIS)

    Samsudin, Emy Marlina; Abd Hamid, Sharifah Bee

    2017-01-01

    Highlights: • Band gap engineering using anion dopants. • Mid band energy level. • Ti 3+ and oxygen vacancies as impurities states. • Valence band tail extension due to doping. • Wider solar light absorption. - Abstract: A simple yet promising strategy to modify TiO 2 band gap was achieved via dopants incorporation which influences the photo-responsiveness of the photocatalyst. The mesoporous TiO 2 was successfully mono-doped and co-doped with nitrogen and fluorine dopants. The results indicate that band gap engineering does not necessarily requires oxygen substitution with nitrogen or/and fluorine, but from the formation of additional mid band and Ti 3+ impurities states. The formation of oxygen vacancies as a result of modified color centres and Ti 3+ ions facilitates solar light absorption and influences the transfer, migration and trapping of the photo-excited charge carriers. The synergy of dopants in co-doped TiO 2 shows better optical properties relative to single N and F doped TiO 2 with c.a 0.95 eV band gap reduction. Evidenced from XPS, the synergy between N and F in the co-doped TiO 2 uplifts the valence band towards the conduction band. However, the photoluminescence data reveals poorer electrons and holes separation as compared to F-doped TiO 2 . This observation suggests that efficient solar light harvesting was achievable via N and F co-doping, but excessive defects could act as charge carriers trapping sites.

  4. Effect of band gap engineering in anionic-doped TiO{sub 2} photocatalyst

    Energy Technology Data Exchange (ETDEWEB)

    Samsudin, Emy Marlina; Abd Hamid, Sharifah Bee, E-mail: sharifahbee@um.edu.my

    2017-01-01

    Highlights: • Band gap engineering using anion dopants. • Mid band energy level. • Ti{sup 3+} and oxygen vacancies as impurities states. • Valence band tail extension due to doping. • Wider solar light absorption. - Abstract: A simple yet promising strategy to modify TiO{sub 2} band gap was achieved via dopants incorporation which influences the photo-responsiveness of the photocatalyst. The mesoporous TiO{sub 2} was successfully mono-doped and co-doped with nitrogen and fluorine dopants. The results indicate that band gap engineering does not necessarily requires oxygen substitution with nitrogen or/and fluorine, but from the formation of additional mid band and Ti{sup 3+} impurities states. The formation of oxygen vacancies as a result of modified color centres and Ti{sup 3+} ions facilitates solar light absorption and influences the transfer, migration and trapping of the photo-excited charge carriers. The synergy of dopants in co-doped TiO{sub 2} shows better optical properties relative to single N and F doped TiO{sub 2} with c.a 0.95 eV band gap reduction. Evidenced from XPS, the synergy between N and F in the co-doped TiO{sub 2} uplifts the valence band towards the conduction band. However, the photoluminescence data reveals poorer electrons and holes separation as compared to F-doped TiO{sub 2}. This observation suggests that efficient solar light harvesting was achievable via N and F co-doping, but excessive defects could act as charge carriers trapping sites.

  5. [A comparative study on the absorption kinetics parameters of rhubarb free anthraquinones between normal dogs and dogs with severe acute pancreatitis].

    Science.gov (United States)

    Yang, Yong-Mao; Wang, Ping; Zhang, Yan

    2012-04-01

    To study the effects of severe acute pancreatitis (SAP) on absorption kinetic parameters of rhubarb free anthraquinones. Eleven healthy Beagle dogs were randomly divided into the normal group (n = 6) and the SAP group (n = 5). The SAP animal model was prepared by surgery through portal vein blood channel building to collect blood from normal dogs and dogs with SAP. The free anthraquinones (20 mg/kg) was given by gastrogavage. The concentrations of five anthraquinones (aloe emodin, rhein, emodin, chrysophanol, and physcion) in the blood plasma of the portal vein and the femoral artery were determined using high performance liquid chromatography (HPLC). The kinetic parameters were calculated using MATLAB2007B Software. The half life (t(1/2Ka)), the absorption peak time (Tmax), the peak concentration (Cmax), the area under the curve [AUC(0-infinity)], and the mean residence time (MRT) were calculated using the statistical moment method. The transport velocity of corresponding medicines from the gastrointestinal tract to the blood (ka) was calculated. There was no difference in the chemical composition absorption type of the portal vein and the femoral artery between the two groups. Aloe emodin could be detected in the portal vein of each animal at each time point, and they were in the quantitative range. Rhein could be detected in the portal vein of each animal at each time point, and they were lower than the quantitative limit at few time points. Emodin and chrysophanol could be detected in the portal vein of partial animals at each time point, and most of them were higher than the quantitative limit. Physcion could be detected only in the portal vein of less animals at few time points. Rhein could be detected in the femoral artery at most time points, but the rhein plasma concentration at most time points were lower than the quantitative limit. Lower concentration of aloe emodin, emodin, and chrysophanol could be detected in the femoral artery at only few time

  6. [Determination of sulfur in plant using a high-resolution continuum source atomic absorption spectrometer].

    Science.gov (United States)

    Wang, Yu; Li, Jia-xi

    2009-05-01

    A method for the analysis of sulfur (S) in plant by molecular absorption of carbon monosulfide (CS) using a high-resolution continuum source atomic absorption spectrometer (CS AAS) with a fuel-rich air/acetylene flame has been devised. The strong CS absorption band was found around 258 nm. The half-widths of some absorption bands were of the order of picometers, the same as the common atomic absorption lines. The experimental procedure in this study provided optimized instrumental conditions (the ratio of acetylene to air, the burner height) and parameters, and researched the spectral interferences and chemical interferences. The influence of the organic solvents on the CS absorption signals and the different digestion procedures for the determination of sulfur were also investigated. The limit of detection achieved for sulfur was 14 mg x L(-1), using the CS wavelength of 257. 961 nm and a measurement time of 3 s. The accuracy and precision were verified by analysis of two plant standard reference materials. The major applications of this method have been used for the determination of sulfur in plant materials, such as leaves. Compared to the others, this method for the analysis of sulfur is rapid, easy and simple for sulfur determination in plant.

  7. HYBASE : HYperspectral BAnd SElection

    NARCIS (Netherlands)

    Schwering, P.B.W.; Bekman, H.H.P.T.; Seijen, H.H. van

    2009-01-01

    Band selection is essential in the design of multispectral sensor systems. This paper describes the TNO hyperspectral band selection tool HYBASE. It calculates the optimum band positions given the number of bands and the width of the spectral bands. HYBASE is used to assess the minimum number of

  8. Comparative analysis based on replication banding reveals the mechanism responsible for the difference in the karyotype constitution of treefrogs Ololygon and Scinax (Arboranae, Hylidae, Scinaxinae

    Directory of Open Access Journals (Sweden)

    Simone Lilian Gruber

    2017-04-01

    Full Text Available According to the recent taxonomic and phylogenetic revision of the family Hylidae, species of the former Scinax catharinae (Boulenger, 1888 clade were included in the resurrected genus Ololygon Fitzinger, 1843, while species of the Scinax ruber (Laurenti, 1768 clade were mostly included in the genus Scinax Wagler, 1830, and two were allocated to the newly created genus Julianus Duellman et al., 2016. Although all the species of the former Scinax genus shared a diploid number of 2n = 24 and the same fundamental number of chromosome arms of FN = 48, two karyotypic constitutions were unequivocally recognized, related mainly to the distinct size and morphology of the first two chromosome pairs. Some possible mechanisms for these differences had been suggested, but without any experimental evidence. In this paper, a comparison was carried out based on replication chromosome banding, obtained after DNA incorporation of 5-bromodeoxiuridine in chromosomes of Ololygon and Scinax. The obtained results revealed that the loss of repetitive segments in chromosome pairs 1 and 2 was the mechanism responsible for karyotype difference. The distinct localization of the nucleolus organizer regions in the species of both genera also differentiates the two karyotypic constitutions.

  9. Amorphization-induced strong localization of electronic states in CsPbBr3 and CsPbCl3 studied by optical absorption measurements

    Science.gov (United States)

    Kondo, S.; Sakai, T.; Tanaka, H.; Saito, T.

    1998-11-01

    Optical absorption spectra of amorphous CsPbX3 films (X=Br,Cl) are characterized by two Gaussian bands near the fundamental edge, with the optical energy gap largely blueshifted and the absorption intensity strongly reduced as compared with the crystalline films. The peak energies of the bands are close to those of the A and C bands of Pb-doped alkali halides. The spectral features are discussed in terms of a molecular orbital theory based on a quasicomplex Pb2+(X-)6 model similar to the complex model for the doped alkali halides. It is shown that not only Pb2+ 6s and 6p extended states near the band edges but also X- p states contributing to upper valence bands are localized by amorphization. The transitions from the localized Pb2+ 6s to 6p states produce the spin-orbit allowed 3P1 and dipole allowed 1P1 states responsible for the two Gaussians. The localized X- p states lie deeper in energy than the localized Pb2+ 6s state and only contribute to higher-energy absorption above the Gaussian bands, giving the reason for the reduced absorption near the fundamental edge. The blueshift of the optical energy gap is attributed to the disappearance of k dispersions for these one-electron states.

  10. COMPAR

    International Nuclear Information System (INIS)

    Kuefner, K.

    1976-01-01

    COMPAR works on FORTRAN arrays with four indices: A = A(i,j,k,l) where, for each fixed k 0 ,l 0 , only the 'plane' [A(i,j,k 0 ,l 0 ), i = 1, isub(max), j = 1, jsub(max)] is held in fast memory. Given two arrays A, B of this type COMPAR has the capability to 1) re-norm A and B ind different ways; 2) calculate the deviations epsilon defined as epsilon(i,j,k,l): =[A(i,j,k,l) - B(i,j,k,l)] / GEW(i,j,k,l) where GEW (i,j,k,l) may be chosen in three different ways; 3) calculate mean, standard deviation and maximum in the array epsilon (by several intermediate stages); 4) determine traverses in the array epsilon; 5) plot these traverses by a printer; 6) simplify plots of these traverses by the PLOTEASY-system by creating input data blocks for this system. The main application of COMPAR is given (so far) by the comparison of two- and three-dimensional multigroup neutron flux-fields. (orig.) [de

  11. Investigation of microwave absorption property of the core–shell structured Li{sub 0.4}Mg{sub 0.6}Fe{sub 2}O{sub 4}/TiO{sub 2} nanocomposite in X-band region

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Pallab; Hatui, Goutam; Mandal, Avinandan [Materials Science Centre, Indian Institute of Technology, Kharagpur 721302, West Bengal (India); Das, Chapal Kumar, E-mail: chapal12@yahoo.co.in [Materials Science Centre, Indian Institute of Technology, Kharagpur 721302, West Bengal (India); Kumar, Rudresh; Shami, T.C. [Defence Materials and Stores Research and Development Establishment, Kanpur 208013, Uttar Pradesh (India)

    2014-03-25

    Highlights: • Li{sub 0.4}Mg{sub 0.6}Fe{sub 2}O{sub 4} is a new spinel ferrite. • The synthetic procedure is simple and cost effective. • The composite shows core–shell morphology. • The composite shows good magnetic, optical and microwave absorbing properties. • The material shows the maximum reflection loss of −41.6 dB. The thickness of the absorber is only 2.5 mm. -- Abstract: Initially, we have synthesized a magnetic spinel-type ferrite, Li{sub 0.4}Mg{sub 0.6}Fe{sub 2}O{sub 4} (LMF) by a simple chemical coprecipitation method. The LMF particles of different sizes were formed, and the most populated size range is 45–75 nm. Further, the LMF was coated by titanium di-oxide (TiO{sub 2}) via the sol–gel process, and examined the microwave absorption property of TiO{sub 2} coated LMF (Ti@LMF) in the X-band region. The formation of both LMF and Ti@LMF was supported by analysing the materials through different analytical techniques such as X-ray diffraction analysis (XRD), X-ray photoelectron spectroscopy (XPS), and fourier transform infrared (FTIR) spectroscopy. The core–shell morphology of Ti@LMF was confirmed by field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) analysis. The result indicates that the average shell thickness is around 40–50 nm. The optical and magnetic property was studied by UV–VIS spectroscopy and SQUID analysis. Ti@LMF showed excellent microwave absorption property under the thermoplastic polyurethane (TPU) matrix. The maximum reflection loss (−41.6 dB) was measured with the help of Vector Network Analyzer, and the mechanism of absorption was explained by considering the relative complex permittivity and permeability of the prepared materials. The matching of both the dielectric loss (initiated by TiO{sub 2}) and magnetic loss (initiated by LMF) is the main reason for remarkable microwave absorption property of Ti@LMF.

  12. Spectral interferences in atomic absorption spectrometry, (5)

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1979-01-01

    Spectral interferences were observed in trace element analysis of concentrated solutions by atomic absorption spectrometry. Molecular absorption and emission spectra for strontium chloride and nitrate, barium chloride and nitrate containing 12 mg/ml of metal ion in airacetylene flame were measured in the wavelength range from 200 to 700 nm. The absorption and emission spectra of SrO were centered near 364.6 nm. The absorption spectra of SrOH around 606.0, 671.0 and 682.0 nm were very strong. And, emission spectrum of BaOH in the wavelength range from 480 to 550 nm was stronger. But, the absorption of this band spectrum was very weak. In the wavelength range from 200 to 400 nm, some unknown bands of absorption were observed for strontium and barium. Absorption spectra of SrCl and BaCl were observed in the argon-hydrogen flame. Also, in the carbon tube atomizer, the absorption spectra of SrCl and BaCl were detected clearly in the wavelength range from 185 to 400 nm. (author)

  13. On the formation of new reverse micelles: a comparative study of benzene/surfactants/ionic liquids systems using UV-visible absorption spectroscopy and dynamic light scattering.

    Science.gov (United States)

    Falcone, R Darío; Correa, N Mariano; Silber, Juana J

    2009-09-15

    The microenvironment of the polar core generated in different ionic liquid reverse micelle (IL RM) systems were investigated using the solvatochromic behavior of 1-methyl-8-oxyquinolinium betaine (QB) as an absorption probe and dynamic light scattering (DLS) technique. The novel RM systems consist of two different ILs--1-butyl-3-methylimidazolium tetrafluoroborate (bmimBF4) and 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (bmimTf2N)--sequestrated by two different surfactants--Triton X-100 (TX-100) and benzyl-n-hexadecyldimethylammonium chloride (BHDC)--in order to make IL/surfactant/benzene RMs. The effect of the variation of Ws (Ws=[IL]/[surfactant]) on the QB spectroscopy was used to characterize these nonaqueous RMs. DLS results confirm the formation of these IL RM systems because increasing Ws increases the droplet sizes. Moreover it is demonstrated that the structure of the sequestrated ILs depends strongly on the type of surfactant use to create the RMs.

  14. A survey of TiOλ567 nm absorption in solar-type stars

    Science.gov (United States)

    Azizi, Fatemeh; Mirtorabi, Mohammad Taghi

    2018-04-01

    Molecular absorption bands are estimators of stellar activity and spot cycles on magnetically active stars. We have previously introduced a new colour index that compares absorption strength of the titanium oxide (TiO) at 567 nm with nearby continuum. In this paper, we implement this index to measure long-term activity variations and the statistical properties of the index in a sample of 302 solar-type stars from the High Accuracy Radial Velocity Planet search Spectrograph planet search programme. The results indicate a pattern of change in star's activity, covers a range of periods from 2 yr up to 17 yr.

  15. Two-Photon Absorption in Organometallic Bromide Perovskites

    KAUST Repository

    Walters, Grant

    2015-07-21

    Organometallic trihalide perovskites are solution processed semiconductors that have made great strides in third generation thin film light harvesting and light emitting optoelectronic devices. Recently it has been demonstrated that large, high purity single crystals of these perovskites can be synthesized from the solution phase. These crystals’ large dimensions, clean bandgap, and solid-state order, have provided us with a suitable medium to observe and quantify two-photon absorption in perovskites. When CH3NH3PbBr3 single crystals are pumped with intense 800 nm light, we observe band-to-band photoluminescence at 572 nm, indicative of two-photon absorption. We report the nonlinear absorption coefficient of CH3NH3PbBr3 perovskites to be 8.6 cm GW-1 at 800 nm, comparable to epitaxial single crystal semiconductors of similar bandgap. We have leveraged this nonlinear process to electrically autocorrelate a 100 fs pulsed laser using a two-photon perovskite photodetector. This work demonstrates the viability of organometallic trihalide perovskites as a convenient and low-cost nonlinear absorber for applications in ultrafast photonics.

  16. Partial deconvolution of the absorption spectrum of trapped electrons in 15M LiCl aqueous glasses at 77 K

    International Nuclear Information System (INIS)

    Nguyen, T.Q.

    1979-01-01

    Evidence is presented for the composite nature of the solvated (or trapped) electron absorption band in LiCl aqueous glass at 77 K. It is shown that the overall visible absorption spectrum can be deconvoluted into a homogeneously-bleachable 'green' band and a heterogeneously-bleachable 'red' band, whose relative magnitude and absorption band maxima change with the concentration of electrolyte. From the combined results of time resolved and steady state photobleaching experiments, it is concluded that at least two unstable bands are formed during photobleaching (with smaller lifetimes for the band lying further towards the infrared) which then reconverted into the 'green' band with over 40 percent efficiency. (author)

  17. Safety Evaluation of Laparoscopic Sleeve Gastrectomy Compared with Two Procedures of Laparoscopic Roux-en-Y Gastric Bypass and Laparoscopic Adjustable Gastric Banding for Individuals with Morbid Obesity: A Systemic Review

    Directory of Open Access Journals (Sweden)

    F Arabi Basharic

    2015-10-01

    Full Text Available Introduction: Laparoscopic Roux-en-Y gastric bypass and laparoscopic adjustable gastric banding are the most common bariatric surgery procedures. Therefore, this study aims to compare the safety of the newer procedure of Laparoscopic sleeve gastrectomy compared to Laparoscopic Roux-en-Y gastric bypass and Laparoscopic adjustable gastric bonding. Method: A systematic review was conducted on the most important and most relevant search data bases, including Cochrane library, Pubmed, Ovid Medline as well as Iranian sites of Magiran , Iranmedex , SID, not taking the time limit into consideration. The results found in the literature were classified and were then analyzed. Results: Out of 384 articles obtained in the search, 4 randomized clinical trials (RCT were included in this study. There were no reports of death comparing surgical procedures of Roux-en-Y gastric bypass and sleeve gastrectomy. Moreover, in adjustable gastric banding and Roux-en-Y gastric bypass comparison, one death was observed in each group. Regarding the side effects of Roux-en-Y gastric bypass and sleeve gastrectomy, 10% early complications were reported in the Roux-en-Y gastric  bypass group , and 13% were observed in the sleeve gastrectomy group between which no statistically significant difference was revealed. The comparison between adjustable gastric banding and Roux-en-Y gastric bypass demonstrated that the occurrence of early and late complications was reported to be higher in the gastric bypass group, though no statistically significant difference was observed. Conclusion: The present study findings demonstrated no statistically significant difference between these methods in regard with the safety aspect. As a result, selection as well as success of the bariatric surgery procedures depend on the patient's and surgeon's preferences.

  18. Children's phthalate intakes and resultant cumulative exposures estimated from urine compared with estimates from dust ingestion, inhalation and dermal absorption in their homes and daycare centers.

    Directory of Open Access Journals (Sweden)

    Gabriel Bekö

    Full Text Available Total daily intakes of diethyl phthalate (DEP, di(n-butyl phthalate (DnBP, di(isobutyl phthalate (DiBP, butyl benzyl phthalate (BBzP and di(2-ethylhexyl phthalate (DEHP were calculated from phthalate metabolite levels measured in the urine of 431 Danish children between 3 and 6 years of age. For each child the intake attributable to exposures in the indoor environment via dust ingestion, inhalation and dermal absorption were estimated from the phthalate levels in the dust collected from the child's home and daycare center. Based on the urine samples, DEHP had the highest total daily intake (median: 4.42 µg/d/kg-bw and BBzP the lowest (median: 0.49 µg/d/kg-bw. For DEP, DnBP and DiBP, exposures to air and dust in the indoor environment accounted for approximately 100%, 15% and 50% of the total intake, respectively, with dermal absorption from the gas-phase being the major exposure pathway. More than 90% of the total intake of BBzP and DEHP came from sources other than indoor air and dust. Daily intake of DnBP and DiBP from all exposure pathways, based on levels of metabolites in urine samples, exceeded the Tolerable Daily Intake (TDI for 22 and 23 children, respectively. Indoor exposures resulted in an average daily DiBP intake that exceeded the TDI for 14 children. Using the concept of relative cumulative Tolerable Daily Intake (TDI(cum, which is applicable for phthalates that have established TDIs based on the same health endpoint, we examined the cumulative total exposure to DnBP, DiBP and DEHP from all pathways; it exceeded the tolerable levels for 30% of the children. From the three indoor pathways alone, several children had a cumulative intake that exceeded TDI(cum. Exposures to phthalates present in the air and dust indoors meaningfully contribute to a child's total intake of certain phthalates. Such exposures, by themselves, may lead to intakes exceeding current limit values.

  19. Microwave non-resonant absorption in fine cobalt ferrite particles

    International Nuclear Information System (INIS)

    Mata-Zamora, M.E.; Montiel, H.; Alvarez, G.; Saniger, J.M.; Zamorano, R.; Valenzuela, R.

    2007-01-01

    Cobalt ferrite particles of average crystallite size of 11 nm were obtained by a sol-gel process at 400 deg. C . The powders were annealed at temperatures of 500, 600, 700 and 800 deg. C in air. Derivative microwave power absorption (dP/dH) measurements were carried out as a function of magnetic field (H DC ) at X band (9.4 GHz), in the field range -80-796 kA/m for all annealed temperatures. In order to compare the response of saturation magnetization measurements with high frequency measurements, we calculated the areas inside both the magnetization (A M ) and the absorption hysteresis loops (A LFS ). The dependence of these areas as a function of crystallite size is remarkably similar in both experiments

  20. Medieval glass from the Cathedral in Paderborn: a comparative study using X-ray absorption spectroscopy, X-ray fluorescence, and inductively coupled laser ablation mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hormes, J. [University of Saskatchewan, Canadian Light Source Inc., Saskatoon, SK (Canada); Louisiana State University, CAMD, Baton Rouge, LA (United States); Roy, A.; Bovenkamp, G.L. [Louisiana State University, CAMD, Baton Rouge, LA (United States); Simon, K. [University of Goettingen, Geochemistry, Centre for Geosciences, Goettingen (Germany); Kim, C.Y. [University of Saskatchewan, Canadian Light Source Inc., Saskatoon, SK (Canada); Boerste, N. [Faculty for Theology Paderborn, Paderborn (Germany); Gai, S. [LWL - Archaeologie fuer Westfalen, Muenster (Germany)

    2013-04-15

    We have investigated four stained glass samples recovered from an archaeological excavation at the Cathedral in Paderborn (Germany) between 1978 and 1980. On two of the samples there are parts of paintings. Concentrations of major elements were determined using two independent techniques: LA-ICP-MS (a UV laser ablation microsampler combined with an inductively coupled plasma mass spectrometer) and synchrotron radiation X-ray excited X-ray fluorescence (SR-XRF). The SR-XRF data were quantified by using the program package PyMCA developed by the software group of the ESRF in Grenoble. Significant differences were found between the concentrations determined by the two techniques that can be explained by concentration gradients near the surface of the glasses caused, for example, by corrosion/leaching processes and the different surface sensitivities of the applied techniques. For several of the elements that were detected in the glass and in the colour pigments used for the paintings X-ray absorption near edge structure (XANES) spectra were recorded in order to determine the chemical speciation of the elements of interest. As was expected, most elements in the glass were found as oxides in their most stable form. Two notable exceptions were observed: titanium was not found as rutile - the most stable form of TiO{sub 2} - but in the form of anatase, and lead was not found in one defined chemical state but as a complex mixture of oxide, sulphate, and other compounds. (orig.)

  1. Children's Phthalate Intakes and Resultant Cumulative Exposures Estimated from Urine Compared with Estimates from Dust Ingestion, Inhalation and Dermal Absorption in Their Homes and Daycare Centers

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Weschler, Charles J; Langer, Sarka

    2013-01-01

    Total daily intakes of diethyl phthalate (DEP), di(n-butyl) phthalate (DnBP), di(isobutyl) phthalate (DiBP), butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) were calculated from phthalate metabolite levels measured in the urine of 431 Danish children between 3 and 6 years of a...... of certain phthalates. Such exposures, by themselves, may lead to intakes exceeding current limit values.......Total daily intakes of diethyl phthalate (DEP), di(n-butyl) phthalate (DnBP), di(isobutyl) phthalate (DiBP), butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) were calculated from phthalate metabolite levels measured in the urine of 431 Danish children between 3 and 6 years of age....... For each child the intake attributable to exposures in the indoor environment via dust ingestion, inhalation and dermal absorption were estimated from the phthalate levels in the dust collected from the child's home and daycare center. Based on the urine samples, DEHP had the highest total daily intake...

  2. Intensity formulas for triplet bands

    Science.gov (United States)

    Budo, A.

    1982-01-01

    Previous work in this area is surveyed and the mathematics involved in determining the quantitative intensity measurements in triplet bands is presented. Explicit expressions for the intensity distribution in the branches of the 3 Sigma-3 Pi and 1 Sigma-3Pi bands valid for all values of the coupling constant Y of the 3 Pi terms are given. The intensity distribution calculated according to the formulas given is compared with measurements of PH, 3 Pi-3 Sigma. Good quantitative agreement is obtained.

  3. Observation of enhanced infrared absorption in silicon supersaturated with gold by pulsed laser melting of nanometer-thick gold films

    Science.gov (United States)

    Chow, Philippe K.; Yang, Wenjie; Hudspeth, Quentin; Lim, Shao Qi; Williams, Jim S.; Warrender, Jeffrey M.

    2018-04-01

    We demonstrate that pulsed laser melting (PLM) of thin 1, 5, and 10 nm-thick vapor-deposited gold layers on silicon enhances its room-temperature sub-band gap infrared absorption, as in the case of ion-implanted and PLM-treated silicon. The former approach offers reduced fabrication complexity and avoids implantation-induced lattice damage compared to ion implantation and pulsed laser melting, while exhibiting comparable optical absorptance. We additionally observed strong broadband absorptance enhancement in PLM samples made using 5- and 10-nm-thick gold layers. Raman spectroscopy and Rutherford backscattering analysis indicate that such an enhancement could be explained by absorption by a metastable, disordered and gold-rich surface layer. The sheet resistance and the diode electrical characteristics further elucidate the role of gold-supersaturation in silicon, revealing the promise for future silicon-based infrared device applications.

  4. Strain-induced optical absorption properties of semiconductor nanocrystals.

    Science.gov (United States)

    Zhang, Ai; Luo, Sheng; Ouyang, Gang; Yang, Guowei

    2013-06-28

    As comparable to the spherical nanocrystals, the nanocrystals with non-spherical shape have fascinating properties induced by a large fraction of under-coordinated atoms located at end parts, including edges, vertexes, and side facets. Herein, taking into account the shell-core configuration of semiconductor nanospheres, nanocubes, and nanorods, we investigate the self-equilibrium strain on optical absorption properties from the perspective of atomistic origin. It has been found that the band gap of nanocrystals exhibits a pronounced blueshift compared with that of the bulk counterpart, and further shown that the band gap of nanospheres is different from that of naoncubes and nanorods. Moreover, we demonstrate that the shape effects have weak influences on the absorption coefficient when the crystal size approaches to a threshold value that is much smaller than the exciton Bohr radius at short wavelengths. Remarkably, the nanocubes have the largest deformation potential compared to the nanorods and nanospheres at fixed strain. The physical origin can be ascribed to the self-equilibrium strain induced by end effects that changes the bonding identifies, which leads to the variations of cohesive energy and entire Hamiltonian of nanocrystals. Our theoretical predictions not only are consistent with the experimental measurements and simulations, but also indicate the possible method on tunable optical properties of semiconductor nanocrystals.

  5. Cu K-edge X-ray Absorption Spectroscopy Reveals Differential Copper Coordimation Within Amyloid-beta Oligomers Compared to Amyloid-beta Monomers

    Energy Technology Data Exchange (ETDEWEB)

    J Shearer; P Callan; T Tran; V Szalai

    2011-12-31

    The fatal neurodegenerative disorder Alzheimer's disease (AD) has been linked to the formation of soluble neurotoxic oligomers of amyloid-{beta} (A{beta}) peptides. These peptides have high affinities for copper cations. Despite their potential importance in AD neurodegeneration few studies have focused on probing the Cu{sup 2+/1+} coordination environment within A{beta} oligomers. Herein we present a Cu K-edge X-ray absorption spectroscopic study probing the copper-coordination environment within oligomers of A{beta}(42) (sequence: DAEFRHDSGYEVHHQKLVFFAEDVGSNKGAIIGLMVGGVVIA). We find that the Cu{sup 2+} cation is contained within a square planar mixed N/O ligand environment within A{beta}(42) oligomers, which is similar to the copper coordination environment of the monomeric forms of {l_brace}Cu{sup II}A{beta}(40){r_brace} and {l_brace}Cu{sup II}A{beta}(16){r_brace}. Reduction of the Cu{sup 2+} cation within the A{beta}(42) oligomers to Cu{sup 1+} yields a highly dioxygen sensitive copper-species that contains Cu{sup 1+} in a tetrahedral coordination geometry. This can be contrasted with monomers of {l_brace}Cu{sup I}A{beta}(40){r_brace} and {l_brace}Cu{sup I}A{beta}(16){r_brace}, which contain copper in a dioxygen inert linear bis-histidine ligand environment [Shearer and Szalai, J. Am. Chem. Soc., 2008, 130, 17826]. The biological implications of these findings are discussed.

  6. Quantitative comparisons of absorption cross-section spectra and integrated intensities of HFC-143a

    International Nuclear Information System (INIS)

    Le Bris, Karine; Graham, Laura

    2015-01-01

    The integrated absorption cross-sections of HFC-143a (CH 3 CF 3 ) differ substantially in the literature. This leads to an important uncertainty on the value of the radiative efficiency of this molecule. The ambiguity on the absorption cross-sections of HFC-143a is highlighted by the existence of two significantly different datasets in the HITRAN database. To solve the issue, we performed high-resolution Fourier transform infrared laboratory measurements of HFC-13a and compared the spectra with the two HITRAN datasets and with the data from the Pacific Northwest National Laboratory (PNNL). The experimental methods and data analysis techniques are examined and typical sources of errors are discussed. The integrated intensities of the main bands are compared to other literature values. It was found that the integrated absorption cross-section values in the highest range – around 13.8×10 −17 cm.molecule −1 in the 570–1500 cm −1 spectral band – show the most consistency between authors. - Highlights: • Large discrepancies exist between authors on the absorption spectra of HFC-143a. • We present new cross-section spectra of a pure vapour at 263, 273 and 283 K. • The data were compared to literature values. • Total integrated intensities in the highest range are the most consistent. • The radiative efficiency of HFC-143a should be revised upward

  7. A cylindrical furnace for absorption spectral studies

    Indian Academy of Sciences (India)

    Unknown

    our laboratory. The components and accessories required for operating this furnace are described here. The salient feature of this furnace is that it contains three separate heating zones. The heating zone at .... spectrograph, the electronic absorption spectrum of C1Π ← X1Σ system of InBr at. ~ 2800 Å. The bands of C ← X ...

  8. An open labeled, comparative clinical study on efficacy and tolerability of oral minipulse of steroid (OMP alone, OMP with PUVA and broad / narrow band UVB phototherapy in progressive vitiligo

    Directory of Open Access Journals (Sweden)

    Rath Namita

    2008-01-01

    Full Text Available Background: Several modalities of treatment have been tried in vitiligo with varied results; however, Indian data on comparative studies of two or more therapies are limited. Aims: We compared different phototherapy methods with an oral steroid as an adjunct to determine the method with the best tolerability and efficacy. Methods: Eighty-six patients with progressive vitiligo were randomly assigned to different study groups according to a continuous selection method over a period of one year. Group 1 was given OMP + PUVA, group 2 OMP + UVB (NB, group 3 OMP + UVB (BB and group 4 was given OMP alone. Each patient was followed up for six months and then released from treatment. Clinical evaluation was made at the end of three and six months. Results: In group 1 (OMP + PUVA, marked improvement was seen in 18.51% while moderate improvement was seen in 66.66% of the patients. Marked improvement was seen in 37.03% in group 2 (OMP + NB-UVB while 44.44% had moderate improvement. In group 3 (OMP + BB UVB, 8.33% showed marked improvement while moderate improvement was seen in 25% of the patients. Marked and moderate improvement was seen in 5 and 10% of group 4 (OMP patients, respectively. Conclusions: Our study compared four treatment modalities in vitiligo patients, out of which oral minipulse of steroids (OMP only had an adjunct value and was not very effective by itself. Narrow band UVB has a definite edge over broad band UVB and should be preferred when both options are available. NB-UVB and PUVA showed comparable efficacy.

  9. Optical absorption of tetraphenylporphyrin thin films in UV-vis-NIR region.

    Science.gov (United States)

    El-Nahass, M M; Zeyada, H M; Aziz, M S; Makhlouf, M M

    2005-11-01

    The optical absorption of thermally evaporated tetraphenylporphyrin (TPP) in the UV-vis-NIR region have been studied. The absorption spectra recorded in the UV-vis region for the as deposited and annealed films showed different absorption bands, namely the Soret(B) at region 360-490nm, Q-band region consist of four bands in the region 500-720nm and two other bands labeled N and M in UV region. The Soret band always shows its characteristic effect splitting in all the TPP thin films and the effect of annealing on the intensities of these components have been observed. The spectra of the infrared absorption allow characterization of vibrational modes for the powder, as deposited and annealed thin films. Some of the optical absorption parameters, namely molar extinction coefficient, epsilon, half band width, Deltalambda, electronic dipole strength, q(2) and oscillator strength, f, of the principle optical transitions have also been evaluated.

  10. ABSORPTIONS IN THE VISIBLE OF PROTONATED PYRENE COLLISIONALLY COOLED TO 15 K

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, F.-X.; Gause, O.; Rice, C. A.; Maier, J. P., E-mail: j.p.maier@unibas.ch [Department of Chemistry, University of Basel, Klingelbergstr. 80, 4056-CH Basel (Switzerland)

    2013-12-01

    Protonated polycyclic hydrocarbons have been added to the list of suggested carriers of diffuse interstellar absorptions. To test this proposition requires laboratory spectra measured under interstellar conditions, in particular with the rotational and vibrational degrees of freedom equilibrated to low temperatures. This has been achieved for protonated pyrene with absorption bands in the visible, using an ion trap and collisional cooling to ≈15 K. A two-photon excitation-dissociation scheme was employed to record the (1) {sup 1} A' ← X {sup 1} A' electronic spectrum on around 10{sup 5} ions per duty cycle. The origin band of the absorption spectrum of this relatively large polycyclic aromatic species with 27 atoms is located at 4858.86 Å. Two further comparably intense spectral features are present at 4834.48 and 4809.32 Å. This is one of the largest protonated aromatics studied in the gas phase and compared to astronomical observations; however, it is not a carrier of known diffuse interstellar bands.

  11. Band structure of semiconductors

    CERN Document Server

    Tsidilkovski, I M

    2013-01-01

    Band Structure of Semiconductors provides a review of the theoretical and experimental methods of investigating band structure and an analysis of the results of the developments in this field. The book presents the problems, methods, and applications in the study of band structure. Topics on the computational methods of band structure; band structures of important semiconducting materials; behavior of an electron in a perturbed periodic field; effective masses and g-factors for the most commonly encountered band structures; and the treatment of cyclotron resonance, Shubnikov-de Haas oscillatio

  12. Dual band metamaterial perfect absorber based on Mie resonances

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaoming; Lan, Chuwen; Li, Bo; Zhou, Ji, E-mail: zhouji@tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Bi, Ke [School of Science, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Zhao, Qian [State Key Lab of Tribology, Department of Precision Instruments and Mechanology, Tsinghua University, Beijing 100084 (China)

    2016-08-08

    We numerically and experimentally demonstrated a polarization insensitive dual-band metamaterial perfect absorber working in wide incident angles based on the two magnetic Mie resonances of a single dielectric “atom” with simple structure. Two absorption bands with simulated absorptivity of 99% and 96%, experimental absorptivity of 97% and 94% at 8.45 and 11.97 GHz were achieved due to the simultaneous magnetic and electric resonances in dielectric “atom” and copper plate. Mie resonances of dielectric “atom” provide a simple way to design metamaterial perfect absorbers with high symmetry.

  13. A comparative chromosome analysis of Thai wild boar (Sus scrofa jubatus and relationship to domestic pig (S. s. domestica by conventional staining, G-banding and high-resolution technique

    Directory of Open Access Journals (Sweden)

    Pornnarong Siripiyasing

    2007-01-01

    Full Text Available This research is the first comparative chromosome analysis report of Thai wild boar (Sus scrofa jubatus and its relationship to domestic pig (S. s. domestica by conventional staining, G-banding and high-resolution technique. Blood samples of the Thai wild boar were taken from two males and two females kept in Nakhon Ratchasima Zoo. After standard whole blood lymphocyte culture at 37 oC for 72 hr. in the presence of colchicine, the metaphase spreads were performed on microscopic slides and airdried. Conventional staining, G-banding and high-resolution technique were applied to stain the chromosomes. The results showed that the number of diploid chromosomes of Thai wild boar was 2n (diploid = 38, and the fundamental numbers (NF were 62 in the male and female. The type of autosomes were 12 metacentric, 14 submetacentric, 4 acrocentric and 6 telocentric chromosomes, with X and Y chromosomes being metacentric chromosomes. We found that chromosomes 1, 5, 7, 8, 10, 11, 12, 13, 14, 16, 17, 18, X and Y had the same Gbanding and high-resolution technique patterns as those of domestic pig chromosomes. Chromosomes 2, 3, 4, 6, 9 and 15 are similar to those of domestic pig chromosomes. These results show the evolutionary relationship between the Thai wild boar and the domestic pig.

  14. Iron absorption studies

    International Nuclear Information System (INIS)

    Ekenved, G.

    1976-01-01

    The main objective of the present work was to study iron absorption from different iron preparations in different types of subjects and under varying therapeutic conditions. The studies were performed with different radioiron isotope techniques and with a serum iron technique. The preparations used were solutions of ferrous sulphate and rapidly-disintegrating tablets containing ferrous sulphate, ferrous fumarate and ferrous carbonate and a slow-release ferrous sulphate tablet of an insoluble matrix type (Duroferon Durules). The serum iron method was evaluated and good correlation was found between the serum iron response and the total amount of iron absorbed after an oral dose of iron given in solution or in tablet form. New technique for studying the in-vivo release properties of tablets was presented. Iron tablets labelled with a radio-isotope were given to healthy subjects. The decline of the radioactivity in the tablets was followed by a profile scanning technique applied to different types of iron tablets. The release of iron from the two types of tablets was shown to be slower in vivo than in vitro. It was found that co-administration of antacids and iron tablets led to a marked reduction in the iron absorption and that these drugs should not be administered sumultaneously. A standardized meal markedly decreased the absorbability of iron from iron tablets. The influence of the meal was more marked with rapidly-disintegrating than with slow-release ferrous sulphate tablets. The absorption from rapidly-disintegrating and slow-release ferrous sulphate tablets was compared under practical clinical conditions during an extended treatment period. The studies were performed in healthy subjects, blood donors and patients with iron deficiency anaemia and it was found that the absorption of iron from the slow-release tablets was significantly better than from the rapidly-disintegrating tablets in all three groups of subjects. (author)

  15. Microwave absorption studies of MgB 2 superconductor

    Indian Academy of Sciences (India)

    Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. The modulated low-field microwave absorption signals recorded for polycrystalline (grain size ∼ 10m) samples suggested the absence of weak-link character. The field dependent direct microwave ...

  16. UV- Radiation Absorption by Ozone in a Model Atmosphere using ...

    African Journals Online (AJOL)

    UV- radiation absorption is studied through variation of ozone transmittance with altitude in the atmosphere for radiation in the 9.6μm absorption band using Goody's model atmosphere with cubic spline interpolation technique to improve the quality of the curve. The data comprising of pressure and temperature at different ...

  17. Infrared absorption spectroscopic study of Nd substituted Zn–Mg ...

    Indian Academy of Sciences (India)

    Unknown

    results from IR absorption study can be used to interpret the electrical and magnetic properties of the ferrites. (Braber 1969). The absorption bands, from which the details regarding functional groups and their linkages can be explored, are found to be dependent on atomic mass, cationic radius, cation–anion bond distances, ...

  18. Propionaldehyde infrared cross-sections and band strengths

    International Nuclear Information System (INIS)

    Köroğlu, Batikan; Loparo, Zachary; Nath, Janardan; Peale, Robert E.; Vasu, Subith S.

    2015-01-01

    The use of oxygenated biofuels reduces the greenhouse gas emissions; however, they also result in increased toxic aldehyde by-products, mainly formaldehyde, acetaldehyde, acrolein, and propionaldehyde. These aldehydes are carcinogenic and/or toxic and therefore it is important to understand their formation and destruction pathways in combustion and atmospheric systems. Accurate information about their infrared cross-sections and integrated strengths are crucially needed for development of quantitative detection schemes and modeling tools. Critical to the development of such diagnostics are accurate characterization of the absorption features of these species. In this study, the gas phase infrared spectra of propionaldehyde (also called propanal, CH 3 –CH 2 –CHO), a saturated three carbon aldehyde found in the exhaust emissions of biodiesel or diesel fuels, was studied using high resolution Fourier Transform Infrared (FTIR) spectroscopy over the wavenumber range of 750−3300 cm −1 and at room temperature 295 K. The absorption cross sections of propionaldehyde were recorded at resolutions of 0.08 and 0.096 cm −1 and at seven different pressures (4−33 Torr). The calculated band-strengths were reported and the integrated band intensity results were compared with values taken from the Pacific Northwest National Laboratory (PNNL) database (showing less than 2% discrepancy). The peak positions of the 19 different vibrational bands of propionaldehyde were also compared with previous studies taken at a lower resolution of 1 cm −1 . To the best of our knowledge, the current FTIR measurements provide the first highest resolution infrared cross section data for propionaldehyde. - Highlights: • High resolution IR spectra of propionaldehyde were measured by FTIR spectrometer. • The discrepancy between the present study and PNNL database was less than 2%. • The fundamental vibrational frequencies were reported at high resolution. • The rovibrational Q

  19. Propionaldehyde infrared cross-sections and band strengths

    Science.gov (United States)

    Köroğlu, Batikan; Loparo, Zachary; Nath, Janardan; Peale, Robert E.; Vasu, Subith S.

    2015-02-01

    The use of oxygenated biofuels reduces the greenhouse gas emissions; however, they also result in increased toxic aldehyde by-products, mainly formaldehyde, acetaldehyde, acrolein, and propionaldehyde. These aldehydes are carcinogenic and/or toxic and therefore it is important to understand their formation and destruction pathways in combustion and atmospheric systems. Accurate information about their infrared cross-sections and integrated strengths are crucially needed for development of quantitative detection schemes and modeling tools. Critical to the development of such diagnostics are accurate characterization of the absorption features of these species. In this study, the gas phase infrared spectra of propionaldehyde (also called propanal, CH3-CH2-CHO), a saturated three carbon aldehyde found in the exhaust emissions of biodiesel or diesel fuels, was studied using high resolution Fourier Transform Infrared (FTIR) spectroscopy over the wavenumber range of 750-3300 cm-1 and at room temperature 295 K. The absorption cross sections of propionaldehyde were recorded at resolutions of 0.08 and 0.096 cm-1 and at seven different pressures (4-33 Torr). The calculated band-strengths were reported and the integrated band intensity results were compared with values taken from the Pacific Northwest National Laboratory (PNNL) database (showing less than 2% discrepancy). The peak positions of the 19 different vibrational bands of propionaldehyde were also compared with previous studies taken at a lower resolution of 1 cm-1. To the best of our knowledge, the current FTIR measurements provide the first highest resolution infrared cross section data for propionaldehyde.

  20. Optical absorption and fluorescence properties of Er in sodium ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Spectroscopic properties of Er3+ ions in sodium borate glass have been studied. The indirect and direct optical band gaps (Eopt) and energy level parameters (Racah (E1, E2 and E3), spin-orbit (ξ4f) and con- figurational interaction (α)) are evaluated. Spectral intensities for various absorption bands of Er3+ doped.

  1. Evaluation of bulk and surfaces absorption edge energy of sol-gel-dip-coating SnO2 thin films

    Directory of Open Access Journals (Sweden)

    Emerson Aparecido Floriano

    2010-12-01

    Full Text Available The absorption edge and the bandgap transition of sol-gel-dip-coating SnO2 thin films, deposited on quartz substrates, are evaluated from optical absorption data and temperature dependent photoconductivity spectra. Structural properties of these films help the interpretation of bandgap transition nature, since the obtained nanosized dimensions of crystallites are determinant on dominant growth direction and, thus, absorption energy. Electronic properties of the bulk and (110 and (101 surfaces are also presented, calculated by means of density functional theory applied to periodic calculations at B3LYP hybrid functional level. Experimentally obtained absorption edge is compared to the calculated energy band diagrams of bulk and (110 and (101 surfaces. The overall calculated electronic properties in conjunction with structural and electro-optical experimental data suggest that the nature of the bandgap transition is related to a combined effect of bulk and (101 surface, which presents direct bandgap transition.

  2. Effect of band gap engineering in anionic-doped TiO2 photocatalyst

    Science.gov (United States)

    Samsudin, Emy Marlina; Abd Hamid, Sharifah Bee

    2017-01-01

    A simple yet promising strategy to modify TiO2 band gap was achieved via dopants incorporation which influences the photo-responsiveness of the photocatalyst. The mesoporous TiO2 was successfully mono-doped and co-doped with nitrogen and fluorine dopants. The results indicate that band gap engineering does not necessarily requires oxygen substitution with nitrogen or/and fluorine, but from the formation of additional mid band and Ti3+ impurities states. The formation of oxygen vacancies as a result of modified color centres and Ti3+ ions facilitates solar light absorption and influences the transfer, migration and trapping of the photo-excited charge carriers. The synergy of dopants in co-doped TiO2 shows better optical properties relative to single N and F doped TiO2 with c.a 0.95 eV band gap reduction. Evidenced from XPS, the synergy between N and F in the co-doped TiO2 uplifts the valence band towards the conduction band. However, the photoluminescence data reveals poorer electrons and holes separation as compared to F-doped TiO2. This observation suggests that efficient solar light harvesting was achievable via N and F co-doping, but excessive defects could act as charge carriers trapping sites.

  3. Iron absorption in relation to iron status

    International Nuclear Information System (INIS)

    Magnusson, B.; Bjoern-Rasmussen, E.; Hallberg, L.; Rossander, L.

    1981-01-01

    The absorption from a 3 mg dose of ferrous iron was measured in 250 male subjects. The absorption was related to the log concentration of serum ferritin in 186 subjects of whom 99 were regular blood donors (r= -0.76), and to bone marrow haemosiderin grading in 52 subjects with varying iron status. The purpose was to try and establish a percentage absorption from such a dose that is representative of subjects who are borderline iron deficient. This information is necessary for food iron absorption studies in order (1) to calculate the absorption of iron from the diet at a given iron status and (2) compare the absorption of iron from different meals studied in different groups of subjects by different investigarors. The results suggest that an absorption of about 40% of a 3 mg reference dose of ferrous iron is given in a fasting state, roughly corresponds to the absorption in borderline-iron-deficient subjects. The results indicate that this 40% absorption value corresponds to a serum ferritin level of 30 μg/l and that food iron absorption in a group of subjects should be expressed preferably as the absorption corresponding to a reference-dose absorption of 45%, or possibly a serum ferritin level of 30 μg/l. (author)

  4. Cermet based metamaterials for multi band absorbers over NIR to LWIR frequencies

    International Nuclear Information System (INIS)

    Pradhan, Jitendra K; Behera, Gangadhar; Anantha Ramakrishna, S; Agarwal, Amit K; Ghosh, Amitava

    2017-01-01

    Cermets or ceramic-metals are known for their use in solar thermal technologies for their absorption across the solar band. Use of cermet layers in a metamaterial perfect absorber allows for flexible control of infra-red absorption over the short wave infra-red, to long wave infra-red bands, while keeping the visible/near infra-red absorption properties constant. We design multilayered metamaterials consisting of a conducting ground plane, a low metal volume fraction cermet/ZnS as dielectric spacer layers, and a top structured layer of an array of circular discs of metal/high volume metal fraction cermet that give rise to specified absorption bands in the near-infra-red (NIR) frequencies, as well as any specified band at SWIR–LWIR frequencies. Thus, a complete decoupling of the absorption at optical/NIR frequencies and the infra-red absorption behaviour of a structured metamaterial is demonstrated. (paper)

  5. Electromagnetic absorption behaviour of ferrite loaded three phase carbon fabric composites

    Science.gov (United States)

    Jagatheesan, Krishnasamy; Ramasamy, Alagirusamy; Das, Apurba; Basu, Ananjan

    2018-02-01

    This article investigates the electromagnetic absorption behaviours of carbon helical yarn fabric reinforced composites and manganese-zinc (Mn-Zn) ferrite particles loaded 3 phase fabric composites. A carbon helical yarn having stainless steel core was prepared and made into single jersey knitted fabric. The composite was prepared by sandwiching a fabric with polypropylene films and thermal pressed. The absorption values of helical yarn fabric composite was observed to be less in the C band region (4-8 GHz). For improving the absorption coefficients of composite, Mn-Zn ferrite particles were dispersed in the polypropylene (PP) composite. The ferrite loaded PP composites exhibited better permittivity and permeability values, hence the absorption loss of the composite was improved. The helical yarn fabric reinforced with Mn-Zn ferrite/PP composite showed larger absorption coefficients than virgin PP/fabric composite. The change in thermal stability and particle size distribution in the Mn-Zn ferrite/PP composite was also analyzed. At higher ferrite concentration, bimodal particle distribution was observed which increased the conductivity and shielding effectiveness (SE) of the composite. In addition, complex permittivity value was also increased for higher incident frequency (4-8 GHz). As the ferrite content increases, the dielectric loss and magnetic permeability of PP/ferrite increases due to increased magnetic loss. Hence, ferrite loaded PP composite showed the total SE of -14.2 dB with the absorption coefficients of 0.717. The S1C7 fabric composite having ferrite dispersion showed the better absorption loss and lower reflection coefficient of 14.2 dB and 0.345 respectively compared to virgin PP/helical yarn fabric composite. The increasing ferrite content (45 wt%) improved the absorption loss and total SE. Though, ferrite based fabric composite exhibits moderate absorptive shielding, it can be used as shielding panels in the electronic industries.

  6. First determination of the valence band dispersion of CH3NH3PbI3 hybrid organic-inorganic perovskite

    Science.gov (United States)

    Lee, Min-I.; Barragán, Ana; Nair, Maya N.; Jacques, Vincent L. R.; Le Bolloc'h, David; Fertey, Pierre; Jemli, Khaoula; Lédée, Ferdinand; Trippé-Allard, Gaëlle; Deleporte, Emmanuelle; Taleb-Ibrahimi, Amina; Tejeda, Antonio

    2017-07-01

    The family of hybrid organic-inorganic halide perovskites is in the limelight because of their recently discovered high photovoltaic efficiency. These materials combine photovoltaic energy conversion efficiencies exceeding 22% and low-temperature and low-cost processing in solution; a breakthrough in the panorama of renewable energy. Solar cell operation relies on the excitation of the valence band electrons to the conduction band by solar photons. One factor strongly impacting the absorption efficiency is the band dispersion. The band dispersion has been extensively studied theoretically, but no experimental information was available. Herein, we present the first experimental determination of the valence band dispersion of methylammonium lead halide in the tetragonal phase. Our results pave the way for contrasting the electronic hopping or the electron effective masses in different theories by comparing to our experimental bands. We also show a significant broadening of the electronic states, promoting relaxed conditions for photon absorption, and demonstrate that the tetragonal structure associated to the octahedra network distortion below 50 °C induces only a minor modification of the electronic bands, with respect to the cubic phase at high temperature, thus minimizing the impact of the cubic-tetragonal transition on solar cell efficiencies.

  7. An infrared metamaterial selective absorber with emitter considering atmospheric absorption for low observability (Conference Presentation)

    Science.gov (United States)

    Kim, Jagyeong; Han, Kiwook; Hahn, Jae W.

    2016-09-01

    Advancement in stealth technology is very crucial for the protection from enemy. Detection of IR electromagnetic wave is performed by detecting the IR radiation from aircraft fuselage or reflected laser by using laser guided missile. In this research, we designed the metamaterial selective absorber with emitter considering atmospheric absorption to minimize observability from these detecting system. The model is designed as T-asymmetric structure for dual-band absorption or emission, and these two parts can be independently tuned. One part is designed as emitter which emit the radiation in the wavelength region where atmospheric absorption is strong. In order to select the target wavelength region, we used the MODTRAN database to calculate the molecular absorption in the atmosphere and strong absorptions occurs at 2μm, 4μm and 5-8μm wavelength regions. The other part is designed as an absorber which absorbs the IR signal from laser guided missile at 1.064μm. Selective emission or absorption at these wavelength region can be achieved by tuning the geometry of the structure. These mechanisms suppose the thermal equilibrium state so that the Kirchhoff law is satisfied. FDTD simulations of the designed structure was conducted to confirm the electromagnetic resonance. Also, we calculated the detected energy from the designed structure and compared with that from conventional aircraft surface. According to the calculation results, the measured signal from the suggested structure decreases to 1/10 of the signal from conventional surface.

  8. In Rwandese Women with Low Iron Status, Iron Absorption from Low-Phytic Acid Beans and Biofortified Beans Is Comparable, but Low-Phytic Acid Beans Cause Adverse Gastrointestinal Symptoms.

    Science.gov (United States)

    Petry, Nicolai; Rohner, Fabian; Gahutu, Jean Bosco; Campion, Bruno; Boy, Erick; Tugirimana, Pierrot L; Zimmerman, Michael Bruce; Zwahlen, Christian; Wirth, James P; Moretti, Diego

    2016-05-01

    Phytic acid (PA) is a major inhibitor of iron bioavailability from beans, and high PA concentrations might limit the positive effect of biofortified beans (BBs) on iron status. Low-phytic acid (lpa) bean varieties could increase iron bioavailability. We set out to test whether lpa beans provide more bioavailable iron than a BB variety when served as part of a composite meal in a bean-consuming population with low iron status. Dietary iron absorption from lpa, iron-biofortified, and control beans (CBs) (regular iron and PA concentrations) was compared in 25 nonpregnant young women with low iron status with the use of a multiple-meal crossover design. Iron absorption was measured with stable iron isotopes. PA concentration in lpa beans was ∼10% of BBs and CBs, and iron concentration in BBs was ∼2- and 1.5-fold compared with CBs and lpa beans, respectively. Fractional iron absorption from lpa beans [8.6% (95% CI: 4.8%, 15.5%)], BBs [7.3% (95% CI: 4.0%, 13.4%)], and CBs [8.0% (95% CI: 4.4%, 14.6%)] did not significantly differ. The total amount of iron absorbed from lpa beans and BBs was 421 μg (95% CI: 234, 756 μg) and 431 μg (95% CI: 237, 786 μg), respectively, and did not significantly differ, but was >50% higher (P beans were hard to cook, and their consumption caused transient adverse digestive side effects in ∼95% of participants. Gel electrophoresis analysis showed phytohemagglutinin L (PHA-L) residues in cooked lpa beans. BBs and lpa beans provided more bioavailable iron than control beans and could reduce dietary iron deficiency. Digestive side effects of lpa beans were likely caused by PHA-L, but it is unclear to what extent the associated digestive problems reduced iron bioavailability. This trial was registered at clinicaltrials.gov as NCT02215278. © 2016 American Society for Nutrition.

  9. Spectral characteristics of banded iron formations in Singhbhum craton, eastern India: Implications for hematite deposits on Mars

    Directory of Open Access Journals (Sweden)

    Mahima Singh

    2016-11-01

    Full Text Available Banded iron formations (BIFs are major rock units having hematite layers intermittent with silica rich layers and formed by sedimentary processes during late Archean to mid Proterozoic time. In terrestrial environment, hematite deposits are mainly found associated with banded iron formations. The BIFs in Lake Superior (Canada and Carajas (Brazil have been studied by planetary scientists to trace the evolution of hematite deposits on Mars. Hematite deposits are extensively identified in Meridiani region on Mars. Many hypotheses have been proposed to decipher the mechanism for the formation of these deposits. On the basis of geomorphological and mineralogical studies, aqueous environment of deposition is found to be the most supportive mechanism for its secondary iron rich deposits. In the present study, we examined the spectral characteristics of banded iron formations of Joda and Daitari located in Singhbhum craton in eastern India to check its potentiality as an analog to the aqueous/marine environment on Mars. The prominent banding feature of banded iron formations is in the range of few millimeters to few centimeters in thickness. Fe rich bands are darker (gray in color compared to the light reddish jaspilitic chert bands. Thin quartz veins (<4 mm are occasionally observed in the hand-specimens of banded iron formations. Spectral investigations have been conducted in VIS/NIR region of electromagnetic spectrum in the laboratory conditions. Optimum absorption bands identified include 0.65, 0.86, 1.4 and 1.9 μm, in which 0.56 and 0.86 μm absorption bands are due to ferric iron and 1.4 and 1.9 μm bands are due to OH/H2O. To validate the mineralogical results obtained from VIS/NIR spectral radiometry, laser Raman and Fourier transform infrared spectroscopic techniques were utilized and the results were found to be similar. Goethite-hematite association in banded iron formation in Singhbhum craton suggests dehydration activity, which has

  10. Band-gap measurements of bulk and nanoscale hematite by soft x-ray spectroscopy

    DEFF Research Database (Denmark)

    Gilbert, B.; Frandsen, Cathrine; Maxey, E.R.

    2009-01-01

    Chemical and photochemical processes at semiconductor surfaces are highly influenced by the size of the band gap, and ability to control the band gap by particle size in nanomaterials is part of their promise. The combination of soft x-ray absorption and emission spectroscopies provides band......-edge to reveal band-edge electronic structure of bulk and nanoscale hematite. Good agreement is found between the hematite band gap derived from optical spectroscopy and the energy separation of the first inflection points in the x-ray absorption and emission onset regions. By applying this method to two sizes...

  11. Effect of doping on the intersubband absorption in Si- and Ge-doped GaN/AlN heterostructures

    Science.gov (United States)

    Ajay, A.; Lim, C. B.; Browne, D. A.; Polaczyński, J.; Bellet-Amalric, E.; Bleuse, J.; den Hertog, M. I.; Monroy, E.

    2017-10-01

    In this paper, we study band-to-band and intersubband (ISB) characteristics of Si- and Ge-doped GaN/AlN heterostructures (planar and nanowires) structurally designed to absorb in the short-wavelength infrared region, particularly at 1.55 μm. Regarding the band-to-band properties, we discuss the variation of the screening of the internal electric field by free carriers, as a function of the doping density and well/nanodisk size. We observe that nanowire heterostructures consistently present longer photoluminescence decay times than their planar counterparts, which supports the existence of an in-plane piezoelectric field associated to the shear component of the strain tensor in the nanowire geometry. Regarding the ISB characteristics, we report absorption covering 1.45-1.75 μm using Ge-doped quantum wells, with comparable performance to Si-doped planar heterostructures. We also report similar ISB absorption in Si- and Ge-doped nanowire heterostructures indicating that the choice of dopant is not an intrinsic barrier for observing ISB phenomena. The spectral shift of the ISB absorption as a function of the doping concentration due to many body effects confirms that Si and Ge efficiently dope GaN/AlN nanowire heterostructures.

  12. High-Resolution IR Absorption Spectroscopy of Polycyclic Aromatic Hydrocarbons in the 3-micrometers Region: Role of Periphery

    Science.gov (United States)

    Maltseva, Elena; Petrignani, Annemieke; Candian, Alessandra; Mackie, Cameron J.; Huang, Xinchuan; Lee, Timothy J.; Tielens, Alexander G. G. M.; Oomens, Jos; Buma, Wybren Jan

    2017-01-01

    In this work we report on high-resolution IR absorption studies that provide a detailed view on how the peripheral structure of irregular polycyclic aromatic hydrocarbons (PAHs) affects the shape and position of their 3-micrometers absorption band. To this purpose we present mass-selected, high-resolution absorption spectra of cold and isolated phenanthrene, pyrene, benz[a]antracene, chrysene, triphenylene, and perylene molecules in the 2950-3150 per cm range. The experimental spectra are compared with standard harmonic calculations, and anharmonic calculations using a modified version of the SPECTRO program that incorporates a Fermi resonance treatment utilizing intensity redistribution. We show that the 3-micrometers region is dominated by the effects of anharmonicity, resulting in many more bands than would have been expected in a purely harmonic approximation. Importantly, we find that anharmonic spectra as calculated by SPECTRO are in good agreement with the experimental spectra. Together with previously reported high-resolution spectra of linear acenes, the present spectra provide us with an extensive dataset of spectra of PAHs with a varying number of aromatic rings, with geometries that range from open to highly-condensed structures, and featuring CH groups in all possible edge configurations. We discuss the astrophysical implications of the comparison of these spectra on the interpretation of the appearance of the aromatic infrared 3-micrometers band, and on features such as the two-component emission character of this band and the 3-micrometers emission plateau.

  13. Nutrition and magnesium absorption

    OpenAIRE

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true magnesium absorption was neither affected by soybean protein in the diet nor by supplemental phytate. The inhibitory influence of soybean protein and phytate on apparent magnesium absorption was found ...

  14. Absorption and excretion tests

    International Nuclear Information System (INIS)

    Berberich, R.

    1988-01-01

    The absorption and excretion of radiopharmaceuticals is still of interest in diagnostic investigations of nuclear medicine. In this paper the most common methods of measuring absorption and excretion are described. The performance of the different tests and their standard values are discussed. More over the basic possibilities of measuring absorption and excretion including the needed measurement equipments are presented. (orig.) [de

  15. Facile preparation and enhanced microwave absorption properties of flake carbonyl iron/Fe{sub 3}O{sub 4} composite

    Energy Technology Data Exchange (ETDEWEB)

    Min, Dandan, E-mail: mdd4776@126.com; Zhou, Wancheng; Luo, Fa; Zhu, Dongmei

    2017-08-01

    Highlights: • Flake carbonyl iron/Fe{sub 3}O{sub 4} composites were prepared by surface oxidation technique. • Lower permittivity and modest permeability was obtained by the FCI/Fe{sub 3}O{sub 4} composites. • Enhanced absorption efficiency and broader absorption band were obtained. - Abstract: Flake carbonyl iron/Fe{sub 3}O{sub 4} (FCI/Fe{sub 3}O{sub 4}) composites with enhanced microwave absorption properties were prepared by a direct and flexible surface oxidation technique. The phase structures, morphology, magnetic properties, frequency-dependent electromagnetic and microwave absorption properties of the composites were investigated. The measurement results showed that lower permittivity as well as modest permeability was obtained by the FCI/Fe{sub 3}O{sub 4} composites. The calculated microwave absorption properties indicated that enhanced absorption efficiency and broader absorption band were obtained by the FCI/Fe{sub 3}O{sub 4} composite comparing with the FCI composite. The absorption frequency range with reflection loss (RL) below −5 dB of FCI/Fe{sub 3}O{sub 4} composites at reaction time of 90 min at thickness of 1.5 mm is 13.3 GHz from 4.7 to 18 GHz, while the bandwidth of the FCI composite is only 5.9 GHz from 2.6 to 8.5 GHz at the same thickness. Thus, such absorbers could act as effective and wide broadband microwave absorbers in the GHz range.

  16. Unidentified atmospheric absorption structure observed by DOAS near Hamburg harbour, Germany

    Science.gov (United States)

    Schmitt, Stefan; Weigelt, Andreas; Mathieu-Üffing, Barbara; Seyler, André; Wittrock, Folkard; Lampel, Johannes; Pöhler, Denis; Platt, Ulrich

    2017-04-01

    Within a six week campaign in July and August 2016, Long Path (LP)-DOAS measurements were performed near the harbour of Hamburg to monitor ship emissions of NO2 and SO2. LP-DOAS instruments retrieve information about the composition of ambient air using active spectroscopy. Therefore, an absorption light path was set up between the northern and the southern riverside of the river Elbe with a total length of ca. 5.7 km. The light of a laser driven Xenon arc lamp was sent to a retro reflector mounted on a light house on the opposite riverside. By comparing the spectrum of the Xenon lamp before and after being sent through the atmosphere, spectral absorption structures of several molecules can be identified and their mixing ratios can be quantified. Besides the well-known trace gas species such as NO2, SO2, O3 and HCHO, a so far unidentified, strong absorption structure could be observed regularly throughout the measurement period. The structure is similar to other known absorption structures in the UV-vis range and can be most likely associated with a molecular absorption cross section. The absorber features a progression of absorption bands in the range of 280 nm to 330 nm with an average band distance of 3 nm to 4 nm. These bands were observed with optical densities of up to 2 per cent along the absorption path. The absorber predominantly occurs during daylight indicating that photolytic processes are most likely to play an important role. Further, direct emission from ships could be excluded by the comparison with NO2 peaks, which serve as a proxy for ship plumes. The respective LP-DOAS instrument was deployed at multiple other measurement sites at the past including rural, urban and remote areas. However, the discussed absorption structure has never been detected before and instrumental errors can be excluded. Currently, MAX-DOAS measurements performed at the same site are evaluated. We will present the spectral features of the putative absorber as well as an

  17. Absorption spectra of trapped holes in anatase TiO2

    DEFF Research Database (Denmark)

    Zawadzki, Pawel

    2013-01-01

    absorption spectroscopy (TAS), but the understanding of the optical absorption due to trapped carriers in TiO2 is incomplete. On the basis of the generalized Δ self-consistent field density functional theory (Δ-SCF DFT) calculations, we attribute the experimentally observed absorption band at 430-550 nm...

  18. Vitamin B12 absorption from eggs.

    Science.gov (United States)

    Doscherholmen, A; McMahon, J; Ripley, D

    1975-09-01

    The assimilation of 57Co B12 from in vivo labeled eggs was much inferior to that of a comparable amount of crystalline 57Co B12. Furthermore, the absorption varied with the form in which the eggs were served. Judged by the urinary excretion test and the plasma absorption of radioactivity the average absorption from boiled and fried eggs was more than twice that from scrambled whole eggs, but less than half that absorbed from crystalline 57Co B12.

  19. Wide Band to ''Double Band'' upgrade

    International Nuclear Information System (INIS)

    Kasper, P.; Currier, R.; Garbincius, P.; Butler, J.

    1988-06-01

    The Wide Band beam currently uses electrons obtained from secondary photon conversions to produce the photon beam incident on the experimental targets. By transporting the positrons produced in these conversions as well as the electrons it is possible to almost double the number of photons delivered to the experiments per primary beam proton. 11 figs

  20. Optical-absorption spectra associated with shallow donor impurities in GaAs-(Ga,Al)As quantum-dots

    International Nuclear Information System (INIS)

    Silva Valencia, J.

    1995-08-01

    The binding energy of a hydrogenic donor impurity and the optical-absorption spectra associated with transitions between the n=1 valence level and the donor-impurity band were calculated for infinite barrier-well spherical GaAs-(Ga,Al)As quantum-dots of different radii, using the effective mass approximation within a variational scheme. An absorption peak associated with transitions involving impurities at the center of the well and a peak related with impurities at the edge of the dot were the main features observed for the different radii of the dots considered in the calculations. Also as a result of the higher electronic confinement in a quantum- dot, we found a much wider energy range of the absorption spectra when compared to infinite GaAs-(Ga,Al)As quantum-wells and quantum-well wires of width and diameter comparable to the diameter of the quantum dot. (author). 13 refs, 3 figs

  1. Study of noise absorption characteristics for current building materials applied in industrial and office rooms

    Directory of Open Access Journals (Sweden)

    Mohsen Aliabadi

    2016-12-01

    Full Text Available Introduction: In Iran country, there is a lack of reliable data on acoustic characteristics of building materials applied in the offices and industrial rooms. This study aimed to investigate noise absorption characteristics for current building and acoustics materials and provided the acoustic database. Method:  In this cross sectional study, the minimum of 60 building and acoustic materials were tested in the acoustics laboratory located in the school of health. Measuring the absorption coefficient was performed using the Impedance Tube (SW60, BSWA along with 1/4’’ Microphone (MPA416 and power amplifier (PA50 in frequency range from 125 to 6300 Hz according to ISO10534-2. The data was analyzed using Excel 2013 software. Results: The results of the sound absorption coefficients for different types of materials were presented based on octave band. The results showed that the increase of sound absorptions by rising the thickness of the chemical foams. The highest absorptions were observed in the medium and high frequencies. However, the impact of materials density on the increase of sound absorption is inconsiderable compared with materials thickness. In view point of sound absorption, the polyurethane foams have better performance than the polyethylene foams. Conclusion: Based on the obtained acoustics database, acoustics professionals can conducted more reliable evaluation about acoustic condition of residential, industrial and office rooms in the design and operation phases. The results confirmed that, material thickness is one of the main features affecting sound absorption especially for high efficiency absorbents like chemical foam. 

  2. Band - Weg interactie

    NARCIS (Netherlands)

    de Boer, Andries; ter Huerne, Henderikus L.; Noordermeer, Jacobus W.M.; Schipper, Dirk J.; prof.dr.ir. Molenaar, A.A.A.

    2008-01-01

    De huidige infrastructuur van wegen waarover men zich snel en comfortabel kan verplaatsen is niet meer weg te denken uit onze maatschappij. Twee “componenten” die hierbij een belangrijke rol spelen zijn het wegdek en de band. Het contact tussen band en wegdek is mede bepalend voor de veiligheid. De

  3. Photonic band structure computations.

    Science.gov (United States)

    Hermann, D; Frank, M; Busch, K; Wolfle, P

    2001-01-29

    We introduce a novel algorithm for band structure computations based on multigrid methods. In addition, we demonstrate how the results of these band structure calculations may be used to compute group velocities and effective photon masses. The results are of direct relevance to studies of pulse propagation in such materials.

  4. ZEBRAFISH CHROMOSOME-BANDING

    NARCIS (Netherlands)

    PIJNACKER, LP; FERWERDA, MA

    1995-01-01

    Banding techniques were carried out on metaphase chromosomes of zebrafish (Danio rerio) embryos. The karyotypes with the longest chromosomes consist of 12 metacentrics, 26 submetacentrics, and 12 subtelocentrics (2n = 50). All centromeres are C-band positive. Eight chromosomes have a pericentric

  5. Investigation of Spectral Band Requirements for Improving Retrievals of Phytoplankton Functional Types

    Directory of Open Access Journals (Sweden)

    Aleksandra Wolanin

    2016-10-01

    Full Text Available Studying phytoplankton functional types (PFTs from space is possible due to recent advances in remote sensing. Though a variety of products are available, the limited number of wavelengths available compared to the number of model parameters needed to be retrieved is still a major problem in using ocean-color data for PFT retrievals. Here, we investigated which band placement could improve retrievals of three particular PFTs (diatoms, coccolithophores and cyanobacteria. In addition to analyzing dominant spectral features in the absorption spectra of the target PFTs, two previously-developed methods using measured spectra were applied to simulated data. Such a synthetic dataset allowed for significantly increasing the number of scenarios and enabled a full control over parameters causing spectral changes. We evaluated the chosen band placement by applying an adapted ocean reflectance inversion, as utilized in the generalized inherent optical properties (GIOP retrieval. Results show that the optimal band settings depend on the method applied to determine the bands placement, as well as on the internal variability of the dataset investigated. Therefore, continuous hyperspectral instruments would be most beneficial for discriminating multiple PFTs, though a small improvement in spectral sampling and resolution does not significantly modify the results. Bands, which could be added to future instruments (e.g., Ocean and Land Colour Instrument (OLCI instrument on the upcoming Sentinel-3B,-3C,-3D, etc., and further satellites in order to enhance PFT retrieval capabilities, were also determined.

  6. Comparison of x-ray absorption spectra between water and ice: New ice data with low pre-edge absorption cross-section

    Energy Technology Data Exchange (ETDEWEB)

    Sellberg, Jonas A.; Nilsson, Anders [Department of Physics, AlbaNova University Center, Stockholm University, S-106 91 Stockholm (Sweden); SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Kaya, Sarp [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Segtnan, Vegard H. [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Nofima AS, N-1430 Ås (Norway); Chen, Chen [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Chemistry, Stanford University, Stanford, California 94305 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Ogasawara, Hirohito; Nordlund, Dennis [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, P.O. Box 20450, Stanford, California 94309 (United States); Pettersson, Lars G. M. [Department of Physics, AlbaNova University Center, Stockholm University, S-106 91 Stockholm (Sweden)

    2014-07-21

    The effect of crystal growth conditions on the O K-edge x-ray absorption spectra of ice is investigated through detailed analysis of the spectral features. The amount of ice defects is found to be minimized on hydrophobic surfaces, such as BaF{sub 2}(111), with low concentration of nucleation centers. This is manifested through a reduction of the absorption cross-section at 535 eV, which is associated with distorted hydrogen bonds. Furthermore, a connection is made between the observed increase in spectral intensity between 544 and 548 eV and high-symmetry points in the electronic band structure, suggesting a more extended hydrogen-bond network as compared to ices prepared differently. The spectral differences for various ice preparations are compared to the temperature dependence of spectra of liquid water upon supercooling. A double-peak feature in the absorption cross-section between 540 and 543 eV is identified as a characteristic of the crystalline phase. The connection to the interpretation of the liquid phase O K-edge x-ray absorption spectrum is extensively discussed.

  7. X-ray absorption in atomic potassium

    International Nuclear Information System (INIS)

    Gomilsek, Jana Padeznik; Kodre, Alojz; Arcon, Iztok; Nemanic, Vincenc

    2008-01-01

    A new high-temperature absorption cell for potassium vapor is described. X-ray absorption coefficient of atomic potassium is determined in the energy interval of 600 eV above the K edge where thresholds for simultaneous excitations of 1s and outer electrons, down to [1s2p] excitation, appear. The result represents also the atomic absorption background for XAFS (X-ray absorption fine structure) structure analysis. The K ionization energy in the potassium vapor is determined and compared with theoretical data and with the value for the metal

  8. [Study on lead absorption in pumpkin by atomic absorption spectrophotometry].

    Science.gov (United States)

    Li, Zhen-Xia; Sun, Yong-Dong; Chen, Bi-Hua; Li, Xin-Zheng

    2008-07-01

    A study was carried out on the characteristic of lead absorption in pumpkin via atomic absorption spectrophotometer. The results showed that lead absorption amount in pumpkin increased with time, but the absorption rate decreased with time; And the lead absorption amount reached the peak in pH 7. Lead and cadmium have similar characteristic of absorption in pumpkin.

  9. Design of a dual band metamaterial absorber for Wi-Fi bands

    Science.gov (United States)

    Alkurt, Fatih Özkan; Baǧmancı, Mehmet; Karaaslan, Muharrem; Bakır, Mehmet; Altıntaş, Olcay; Karadaǧ, Faruk; Akgöl, Oǧuzhan; Ünal, Emin

    2018-02-01

    The goal of this work is to design and fabrication of a dual band metamaterial based absorber for Wireless Fidelity (Wi-Fi) bands. Wi-Fi has two different operating frequencies such as 2.45 GHz and 5 GHz. A dual band absorber is proposed and the proposed structure consists of two layered unit cells, and different sized square split ring (SSR) resonators located on each layers. Copper is used for metal layer and resonator structure, FR-4 is used as substrate layer in the proposed structure. This designed dual band metamaterial absorber is used in the wireless frequency bands which has two center frequencies such as 2.45 GHz and 5 GHz. Finite Integration Technique (FIT) based simulation software used and according to FIT based simulation results, the absorption peak in the 2.45 GHz is about 90% and the another frequency 5 GHz has absorption peak near 99%. In addition, this proposed structure has a potential for energy harvesting applications in future works.

  10. Impact of transporters in oral absorption

    DEFF Research Database (Denmark)

    Gram, Luise Kvisgaard; Rist, Gerda Marie; Steffansen, Bente

    2009-01-01

    was to investigate whether transporters were involved in the intestinal absorption of an organic anion A275 and to compare the impact of interactions related to transporters in the Caco-2 cell model versus the in vivo rat model of intestinal absorption. In both models, it was investigated whether intestinal...... permeation of A275 was concentration dependent and affected by inhibitors or competitive organic anions. Interactions related to transporters in intestinal permeation was clearly demonstrated in the Caco-2 cell model but was not directly evident for in vivo rat absorption. However, an observed biphasic...... in vivo absorption and a large intervariability between rats might mask a dose-dependent absorption of A275. To avoid these suggested interactions, a dose of at least 10 mg/kg, which saturates the intestinal transporters involved in A275 absorption, should be administered, but at doses below that the risk...

  11. A randomized clinical trial in vitamin D-deficient adults comparing replenishment with oral vitamin D3 with narrow-band UV type B light: effects on cholesterol and the transcriptional profiles of skin and blood.

    Science.gov (United States)

    Ponda, Manish P; Liang, Yupu; Kim, Jaehwan; Hutt, Richard; Dowd, Kathleen; Gilleaudeau, Patricia; Sullivan-Whalen, Mary M; Rodrick, Tori; Kim, Dong Joo; Barash, Irina; Lowes, Michelle A; Breslow, Jan L

    2017-05-01

    Background: Vitamin D deficiency, defined as a serum 25-hydroxyvitamin D [25(OH)D] concentration vitamin D supplementation does not lower LDL-cholesterol concentrations or raise HDL-cholesterol concentrations. This uncoupling between association and causation may result from a failure of oral vitamin D to mimic the effect of dermally synthesized vitamin D in response to ultraviolet type B (UVB) light. Objective: We tested the hypothesis that, in vitamin D-deficient adults, the replenishment of vitamin D with UVB exposure would lower LDL-cholesterol concentrations compared with the effect of oral vitamin D 3 supplementation. Design: We performed a randomized clinical trial in vitamin D-deficient adults and compared vitamin D replenishment between subjects who received oral vitamin D 3 ( n = 60) and those who received narrow-band UVB exposure ( n = 58) ≤6 mo. Results: There was no difference in the change from baseline LDL-cholesterol concentrations between oral vitamin D 3 and UVB groups (difference in median of oral vitamin D 3 minus that of UVB: 1.5 mg/dL; 95% CI: -5.0, 7.0 mg/dL). There were also no differences within groups or between groups for changes in total or HDL cholesterol or triglycerides. Transcriptional profiling of skin and blood, however, revealed significant upregulation of immune pathway signaling with oral vitamin D 3 but significant downregulation with UVB. Conclusions: Correcting vitamin D deficiency with either oral vitamin D 3 or UVB does not improve the lipid profile. Beyond cholesterol, these 2 modalities of raising 25(OH)D have disparate effects on gene transcription. This trial was registered at clinicaltrials.gov as NCT01688102. © 2017 American Society for Nutrition.

  12. Absorption Spectra of Gold Nanoparticle Suspensions

    Science.gov (United States)

    Anan'eva, M. V.; Nurmukhametov, D. R.; Zverev, A. S.; Nelyubina, N. V.; Zvekov, A. A.; Russakov, D. M.; Kalenskii, A. V.; Eremenko, A. N.

    2018-02-01

    Three gold nanoparticle suspensions are obtained, and mean radii in distributions - (6.1 ± 0.2), (11.9 ± 0.3), and (17.3 ± 0.7) nm - are determined by the transmission electron microscopy method. The optical absorption spectra of suspensions are obtained and studied. Calculation of spectral dependences of the absorption index of suspensions at values of the gold complex refractive index taken from the literature showed a significant deviation of experimental and calculated data in the region of 450-800 nm. Spectral dependences of the absorption of suspensions are simulated within the framework of the Mie-Drude theory taking into account the interband absorption in the form of an additional term in the imaginary part of the dielectric permittivity of the Gaussian type. It is shown that to quantify the spectral dependences in the region of the plasmon absorption band of nanoparticles, correction of the parameters of the interband absorption is necessary in addition to the increase of the relaxation parameter of the Drude theory. Spectral dependences of the dielectric permittivity of gold in nanodimensional state are refined from the solution of the inverse problem. The results of the present work are important for predicting the special features of operation of photonic devices and optical detonators based on gold nanoparticles.

  13. An ultrathin wide-band planar metamaterial absorber based on a fractal frequency selective surface and resistive film

    International Nuclear Information System (INIS)

    Fan Yue-Nong; Cheng Yong-Zhi; Nie Yan; Wang Xian; Gong Rong-Zhou

    2013-01-01

    We propose an ultrathin wide-band metamaterial absorber (MA) based on a Minkowski (MIK) fractal frequency selective surface and resistive film. This absorber consists of a periodic arrangement of dielectric substrates sandwiched with an MIK fractal loop structure electric resonator and a resistive film. The finite element method is used to simulate and analyze the absorption of the MA. Compared with the MA-backed copper film, the designed MA-backed resistive film exhibits an absorption of 90% at a frequency region of 2 GHz–20 GHz. The power loss density distribution of the MA is further illustrated to explain the mechanism of the proposed MA. Simulated absorptions at different incidence cases indicate that this absorber is polarization-insensitive and wide-angled. Finally, further simulated results indicate that the surface resistance of the resistive film and the dielectric constant of the substrate can affect the absorbing property of the MA. This absorber may be used in many military fields

  14. Design of triple-band polarization controlled terahertz metamaterial absorber

    Science.gov (United States)

    Wang, Ben-Xin; Xie, Qin; Dong, Guangxi; Huang, Wei-Qing

    2018-02-01

    A kind of triple-band polarization tunable terahertz absorber based on a metallic mirror and a metallic patch structure with two indentations spaced by an insulating medium layer is presented. Results prove that three near-perfect absorption peaks with average absorption coefficients of 98.25% are achieved when the polarization angle is equal to zero, and their absorptivities gradually decrease (and even disappear) by increasing the angle of polarization. When the polarization angle is increased to 90°, three new resonance modes with average absorption rates of 96.59% can be obtained. The field distributions are given to reveal the mechanisms of the triple-band absorption and the polarization tunable characteristics. Moreover, by introducing photosensitive silicon materials (its conductivity can be changed by the pump beam) in the indentations of the patch structure, the number of resonance peaks of the device can be actively tuned from triple-band to dual-band. The presented absorbers have potential applications, such as controlling thermal emissivity, and detection of polarization direction of the incident waves.

  15. Modeling of Photonic Band Gap Crystals and Applications

    Energy Technology Data Exchange (ETDEWEB)

    El-Kady, Ihab Fathy [Iowa State Univ., Ames, IA (United States)

    2002-01-01

    In this work, the authors have undertaken a theoretical approach to the complex problem of modeling the flow of electromagnetic waves in photonic crystals. The focus is to address the feasibility of using the exciting phenomena of photonic gaps (PBG) in actual applications. The authors start by providing analytical derivations of the computational electromagnetic methods used in their work. They also present a detailed explanation of the physics underlying each approach, as well as a comparative study of the strengths and weaknesses of each method. The Plane Wave expansion, Transfer Matrix, and Finite Difference time Domain Methods are addressed. They also introduce a new theoretical approach, the Modal Expansion Method. They then shift the attention to actual applications. They begin with a discussion of 2D photonic crystal wave guides. The structure addressed consists of a 2D hexagonal structure of air cylinders in a layered dielectric background. Comparison with the performance of a conventional guide is made, as well as suggestions for enhancing it. The studies provide an upper theoretical limit on the performance of such guides, as they assumed no crystal imperfections and non-absorbing media. Next, they study 3D metallic PBG materials at near infrared and optical wavelengths. The main objective is to study the importance of absorption in the metal and the suitability of observing photonic band gaps in such structures. They study simple cubic structures where the metallic scatters are either cubes or interconnected metallic rods. Several metals are studied (aluminum, gold, copper, and silver). The effect of topology is addressed and isolated metallic cubes are found to be less lossy than the connected rod structures. The results reveal that the best performance is obtained by choosing metals with a large negative real part of the dielectric function, together with a relatively small imaginary part. Finally, they point out a new direction in photonic crystal

  16. Low level optical absorption measurements on organic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Stella, M.; Rojas, F.; Escarre, J.; Asensi, J.M.; Bertomeu, J.; Andreu, J. [Dept. de Fisica Aplicada i Optica, Universitat de Barcelona. Av. Diagonal 647, 08028 Barcelona (Spain); Voz, C.; Puigdollers, J.; Fonrodona, M. [Micro and Nano Technology Group (MNT), Dept. d' Enginyeria Electronica, Universitat Politecnica de Catalunya, C/Jordi Girona 1-3, Campus Nord - Modul C4, 08034 Barcelona (Spain)

    2006-06-15

    The optical absorption of n-type (C{sub 60} and PTCDA) and p-type (CuPc and pentacene) organic semiconductors is investigated by optical transmission and photothermal deflection spectroscopy. The usual absorption bands related to HOMO-LUMO transitions are observed in the high absorption region of transmission spectra. Photothermal deflection spectroscopy also evidences exponential absorption shoulders with characteristic energies 47meV for CuPc, 38meV for pentacene, 50 meV for PTCDA and 87meV for C{sub 60}. In addition, broad bands in the low absorption level are observed for C{sub 60} and PTCDA. These bands have been attributed to contamination due to air exposure. On the other hand, in CuPc a clear absorption peak at 1.12eV is observed with smaller features at 1.04eV, 1.20eV and 1.33eV. These peaks are attributed to transitions between the Pc levels of CuPc ions. Finally, the optical absorption expected in blends of organic semiconductors is estimated by an effective media approximation. (author)

  17. Newer views of the Moon: Comparing spectra from Clementineand the Moon Mineralogy Mapper

    Science.gov (United States)

    Georgiana Y. Kramer,; Sebastian Besse,; Nettles, Jeff; Jean-Philippe Combe,; Clark, Roger N.; Pieters, Carle M.; Matthew Staid,; Joseph Boardman,; Robert Green,; McCord, Thomas B.; Malaret, Erik; Head, James W.

    2011-01-01

    The Moon Mineralogy Mapper (M3) provided the first global hyperspectral data of the lunar surface in 85 bands from 460 to 2980 nm. The Clementine mission provided the first global multispectral maps the lunar surface in 11 spectral bands across the ultraviolet-visible (UV-VIS) and near-infrared (NIR). In an effort to understand how M3 improves our ability to analyze and interpret lunar data, we compare M3 spectra with those from Clementine's UV-VIS and NIR cameras. The Clementine mission provided the first global multispectral maps the lunar surface in 11 spectral bands across the UV-VIS and NIR. We have found that M3 reflectance values are lower across all wavelengths compared with albedos from both of Clementine's UV-VIS and NIR cameras. M3 spectra show the Moon to be redder, that is, have a steeper continuum slope, than indicated by Clementine. The 1 μm absorption band depths may be comparable between the instruments, but Clementine data consistently exhibit shallower 2 μm band depths than M3. Absorption band minimums are difficult to compare due to the significantly different spectral resolutions.

  18. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  19. Tunable electromagnetically induced absorption based on graphene

    Science.gov (United States)

    Cao, Maoyong; Wang, Tongling; Zhang, Huiyun; Zhang, Yuping

    2018-04-01

    In this paper, an electronically induced absorption (EIA) structure based on graphene at the infrared frequency is proposed. A pair of nanorods is coupled to a ring resonator, resulting in electronically induced transparency (EIT), and then, Babinet's principle is applied to transform the EIT structure into an EIA structure. Based on the bright and dark modes of the coupling schemes, the adjustment of the coupling strength between the dark and bright modes can be achieved by changing the asymmetry degree. In addition, the transparency window and the absorption peak can be tuned by changing the Fermi energy of graphene. This graphene-based EIA structure can develop the path in narrow-band filtering and, absorptive switching in the future.

  20. Absorption spectra of AA-stacked graphite

    International Nuclear Information System (INIS)

    Chiu, C W; Lee, S H; Chen, S C; Lin, M F; Shyu, F L

    2010-01-01

    AA-stacked graphite shows strong anisotropy in geometric structures and velocity matrix elements. However, the absorption spectra are isotropic for the polarization vector on the graphene plane. The spectra exhibit one prominent plateau at middle energy and one shoulder structure at lower energy. These structures directly reflect the unique geometric and band structures and provide sufficient information for experimental fitting of the intralayer and interlayer atomic interactions. On the other hand, monolayer graphene shows a sharp absorption peak but no shoulder structure; AA-stacked bilayer graphene has two absorption peaks at middle energy and abruptly vanishes at lower energy. Furthermore, the isotropic features are expected to exist in other graphene-related systems. The calculated results and the predicted atomic interactions could be verified by optical measurements.

  1. Band parameters of phosphorene

    DEFF Research Database (Denmark)

    Lew Yan Voon, L. C.; Wang, J.; Zhang, Y.

    2015-01-01

    Phosphorene is a two-dimensional nanomaterial with a direct band-gap at the Brillouin zone center. In this paper, we present a recently derived effective-mass theory of the band structure in the presence of strain and electric field, based upon group theory. Band parameters for this theory...... are computed using a first-principles theory based upon the generalized-gradient approximation to the density-functional theory. These parameters and Hamiltonian will be useful for modeling physical properties of phosphorene....

  2. Comparative study on intestinal metabolism and absorption in vivo of ginsenosides in sulphur-fumigated and non-fumigated ginseng by ultra performance liquid chromatography quadruple time-of-flight mass spectrometry based chemical profiling approach.

    Science.gov (United States)

    Zhu, He; Shen, Hong; Xu, Jun; Xu, Jin-Di; Zhu, Ling-Ying; Wu, Jie; Chen, Hu-Biao; Li, Song-Lin

    2015-04-01

    Our previous study indicated that sulphur-fumigation of ginseng in post-harvest handling processes could induce chemical transformation of ginsenosides to generate multiple ginsenoside sulphur derivatives. In this study, the influence of sulphur-fumigation on intestinal metabolism and absorption in vivo of ginsenosides in ginseng was sequentially studied. The intestinal metabolic and absorbed profiles of ginsenosides in rats after intra-gastric (i.g.) administration of sulphur-fumigated ginseng (SFG) and non-fumigated ginseng (NFG) were comparatively characterized by a newly established ultra performance liquid chromatography quadruple time-of-flight mass spectrometry (UPLC-QTOF-MS/MS) with electrospray ionization negative (ESI-) mode. A novel strategy based on the characteristic product ions and fragmentation pathways of different types of aglycones (saponin skeletons) and glycosyl moieties was proposed and successfully applied to rapid structural identification of ginsenoside sulphur derivatives and relevant metabolites. In total, 18 ginsenoside sulphur derivatives and 26 ginsenoside sulphur derivative metabolites in the faeces together with six ginsenoside sulphur derivatives in the plasma were identified in the SFG-administrated group but not in the NFG-administrated group. The results clearly demonstrated that the intestinal metabolic and absorbed profiles of ginsenosides in sulphur-fumigated and non-fumigated ginseng were quite different, which inspired that sulphur-fumigation of ginseng should not be recommended before the bioactivity and toxicity of the ginsenoside sulphur derivatives were systematically evaluated. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Laparoscopic gastric banding

    Science.gov (United States)

    ... eat by making you feel full after eating small amounts of food. After surgery, your doctor can adjust the band ... You will feel full after eating just a small amount of food. The food in the small upper pouch will ...

  4. Decay of superdeformed bands

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Khoo, T.L.; Lauritsen, T.

    1995-01-01

    One of the major challenges in the study of superdeformation is to directly connect the large number of superdeformed bands now known to the yrast states. In this way, excitation energies, spins and parities can be assigned to the levels in the second well which is essential to establish the collective and single-particle components of these bands. This paper will review some of the progress which has been made to understand the decay of superdeformed bands using the new arrays including the measurement of the total decay spectrum and the establishment of direct one-step decays from the superdeformed band to the yrast line in 194 Hg. 42 refs., 5 figs

  5. HYBASE - HYperspectral BAnd SElection tool

    NARCIS (Netherlands)

    Schwering, P.B.W.; Bekman, H.H.P.T.; Seijen, H.H. van

    2008-01-01

    Band selection is essential in the design of multispectral sensor systems. This paper describes the TNO hyperspectral band selection tool HYBASE. It calculates the optimum band positions given the number of bands and the width of the spectral bands. HYBASE is used to calculate the minimum number of

  6. Near-infrared diffuse interstellar bands in APOGEE telluric standard star spectra . Weak bands and comparisons with optical counterparts

    Science.gov (United States)

    Elyajouri, M.; Lallement, R.; Monreal-Ibero, A.; Capitanio, L.; Cox, N. L. J.

    2017-04-01

    Aims: Information on the existence and properties of diffuse interstellar bands (DIBs) outside the optical domain is still limited. Additional infra-red (IR) measurements and IR-optical correlative studies are needed to constrain DIB carriers and locate various absorbers in 3D maps of the interstellar matter. Methods: We extended our study of H-band DIBs in Apache Point Observatory Galactic Evolution Experiment (APOGEE) Telluric Standard Star (TSS) spectra. We used the strong λ15273 band to select the most and least absorbed targets. We used individual spectra of the former subsample to extract weaker DIBs, and we searched the two stacked series for differences that could indicate additional bands. High-resolution NARVAL and SOPHIE optical spectra for a subsample of 55 TSS targets were additionally recorded for NIR/optical correlative studies. Results: From the TSS spectra we extract a catalog of measurements of the poorly studied λλ15617, 15653, and 15673 DIBs in ≃300 sightlines, we obtain a first accurate determination of their rest wavelength and constrained their intrinsic width and shape. In addition, we studied the relationship between these weak bands and the strong λ15273 DIB. We provide a first or second confirmation of several other weak DIBs that have been proposed based on different instruments, and we add new constraints on their widths and locations. We finally propose two new DIB candidates. Conclusions: We compared the strength of the λ15273 absorptions with their optical counterparts λλ5780, 5797, 6196, 6283, and 6614. Using the 5797-5780 ratio as a tracer of shielding against the radiation field, we showed that the λ15273 DIB carrier is significantly more abundant in unshielded (σ-type) clouds, and it responds even more strongly than the λ5780 band carrier to the local ionizing field. Full Table 5 is available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc

  7. Hurricane Spiral Bands.

    Science.gov (United States)

    Guinn, Thomas A.; Schubert, Wayne H.

    1993-10-01

    The spiral bands that occur in tropical cyclones can be conveniently divided into two classes-outer bands and inner bands. Evidence is presented here that the outer bands form as the result of nonlinear effects during the breakdown of the intertropical convergence zone (ITCZ) through barotropic instability. In this process a zonal strip of high potential vorticity (the ITCZ shear zone or monsoon trough) begins to distort in a varicose fashion, with the potential vorticity (PV) becoming pooled in local regions that are connected by filaments of high PV. As the pooled regions become more axisymmetric, the filaments become thinner and begin to wrap around the PV centers.It is argued that inner bands form in a different manner. As a tropical cyclone intensifies due to latent heat release, the PV field becomes nearly circular with the highest values of PV in the cyclone center. The radial gradient of PV provides a state on which PV waves (the generalization of Rossby waves) can propagate. The nonlinear breaking of PV waves then leads to an irreversible distortion of the PV contours and a downgradient flux of PV. The continuation of this proem tends to erode the high PV core of the tropical cyclone, to produce a surrounding surf zone, and hence to spread the PV horizontally. In a similar fashion, inner bands can also form by the merger of a vortex with a patch of relatively high PV air. As the merger proem occurs the patch of PV is quickly elongated and wrapped around the vortex. The resulting vortex is generally larger in horizontal extent and exhibits a spiral band of PV.When the formation of outer and inner bands is interpreted in the context of a normal-mode spectral model, they emerge as slow manifold phenomena; that is, they have both rotational and (balanced or slaved) gravitational mode aspects. In this sense, regarding them as simply gravity waves leads to an incomplete dynamical picture.

  8. Optimization of effective absorption enhancement of paired-strips gold nanoantennas arrays in organic thin-films

    Science.gov (United States)

    Yang, Zih-Ying; Su, Chen-Wei; Chen, Kuo-Ping

    2018-01-01

    This study sought to optimize the dimensional characteristics of paired-strips gold nanoantennas embedded in a P3HT: PCBM thin-film by taking into account the tradeoff between the size of the nanostructures and absorber layer as well as the gaps between nanoparticles, to maximize the effective absorption enhancement. The average enhancement behavior within the working region was discussed using integral analysis, which is important for overall enhancement. The discussion would focus on comparing the bands' features of paired-strips nanoantennas embedded in a dielectric thin-film, and in air. By the average absorption 3D slices plots, in which the dimension width, height, and gap are changed with a fixed wavelength; the optimized dimension of paired-strips nanoantennas could be realized. Fixing the period (400 nm) of paired-strips nanoantennas embedded in P3HT:PCBM thin-films (120 nm in thickness) enhanced absorption by 9.8 times.

  9. Soft x-ray-excited luminescence and optical x-ray absorption fine structures of tris (8-hydroxyquinoline) aluminum

    Science.gov (United States)

    Naftel, S. J.; Zhang, P.; Kim, P.-S.; Sham, T. K.; Coulthard, I.; Antel, W. J.; Freeland, J. W.; Frigo, S. P.; Fung, M.-K.; Lee, S. T.; Hu, Y. F.; Yates, B. W.

    2001-03-01

    Photoluminescence from tris (8-hydroxyquinoline) aluminum (Alq3) films has been observed using tunable soft x rays as an excitation source. The photons were tuned to energies above and below the K absorption edges of C, N, O, and Al. The luminescence was in turn used to monitor the absorption. It was found that the luminescence induced by soft x ray exhibits additional emission bands at shorter wavelengths compared to ultraviolet excitation. While all K edges exhibit optical x-ray absorption fine structures (XAFS) similar to those of total electron and fluorescence yield, the optical XAFS at the C K-edge resonance are enhanced for the C1s to π* transitions, indicating site specificity. These observations are attributed to the energetics of the process and the local electronic structure.

  10. Urbach's rule derived from thermal fluctuations in the band-gap energy

    DEFF Research Database (Denmark)

    Skettrup, Torben

    1978-01-01

    The exponential absorption edge (known as Urbach's rule) observed in most materials is interpreted in terms of thermal fluctuations in the band-gap energy. The main contribution to the temperature shift of the band-gap energy is due to the temperature-dependent self-energies of the electrons...... and holes interacting with the phonons. Since the phonon number is fluctuating in thermal equilibrium, the band-gap energy is also fluctuating resulting in an exponential absorption tail below the average band-gap energy. These simple considerations are applied to derive Urbach's rule at high temperatures...

  11. Comparative study on CO{sub 2} absorption speed in aqueous amines solutions; Estudo comparativo da velocidade de absorcao de CO{sub 2} em solucoes aquosas de aminas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Thiago Vinicius [The Dow Chemical Company, Midland, MI (United States); Mello, Lilian; Tavares, Denise; Rodriguez, Henry; Paiva, Jose Luis de [Universidade de Sao Paulo (USP), SP (Brazil)

    2012-07-01

    This study evaluated experimentally the absorption capacity of CO{sub 2} from a mixture CO{sub 2} - ar (10 %mol/mol) into different aqueous solutions of amines, such as MEA, DEA, MDEA and AMP. The absorption tests were carried out in a wetted wall column with promoter film, in laboratory scale. The gas concentration was measured at the inlet and outlet of the absorption column and simultaneously the concentrations at the inlet and oulet of the liquid phase. The analyses of gas and liquid phases were realized by infrared equipment ReactIR 45m. The results were expressed in terms of absorption rate and the relationship between the amount of CO{sub 2} absorbed and the amount of amine fed, to the different solvents. (author)

  12. X-ray absorption near edge spectroscopy at the Mn K-edge in highly homogeneous GaMnN diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Sancho-Juan, O.; Cantarero, A.; Garro, N.; Cros, A. [Materials Science Institute, University of Valencia, PO Box 22085, 46071 Valencia (Spain); Martinez-Criado, G.; Salome, M.; Susini, J. [ESRF, Polygone Scientifique Louis Neel, 6 rue Jules Horowitz, 38000 Grenoble (France); Olguin, D. [Dept. de Fisica, CINVESTAV-IPN, 07300 Mexico D.F. (Mexico); Dhar, S.; Ploog, K. [Paul Drude Institute, Hausvogteiplatz 5-7, 10117 Berlin (Germany)

    2006-06-15

    We have studied by X-ray absorption spectroscopy the local environment of Mn in highly homogeneous Ga{sub 1-x}Mn{sub x}N (0.06absorption near edge spectroscopy (XANES) results. The comparison of the XANES spectra corresponding to the Ga and Mn edges indicates that Mn is substitutional to Ga in all samples studied. The XANES spectra measured at the Mn absorption edge shows in the near-edge region a double peak and a shoulder below the absorption edge and the main absorption peak after the edge, separated around 15 eV above the pre-edge structure. We have compared the position of the edge with that of MnO (Mn{sup 2+}) and Mn{sub 2}O{sub 3} (Mn{sup 3+}). All samples studied present the same Mn oxidation state, 2{sup +}. In order to interprete the near-edge structure, we have performed ab initio calculations with a 2 x 2 x 1supercell ({proportional_to}6% Mn) using the full potential linear augmented plane wave method as implemented in the Wien2k code. The calculations show the appearance of Mn anti-bonding t{sub 2g} bands, which are responsible for the pre-edge absorption. The shoulder and main absorption peaks are due to transitions from the valence band 1s-states of Mn to the p-contributions of the conduction bands. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Solar absorption surface panel

    Science.gov (United States)

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  14. Nutrition and magnesium absorption

    NARCIS (Netherlands)

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true

  15. Zeeman atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Loos-Vollebregt, M.T.C. de.

    1980-01-01

    A new method of background correction in atomic absorption spectroscopy has recently been introduced, based on the Zeeman splitting of spectral lines in a magnetic field. A theoretical analysis of the background correction capability observed in such instruments is presented. A Zeeman atomic absorption spectrometer utilizing a 50 Hz sine wave modulated magnetic field is described. (Auth.)

  16. Transient absorption and luminescence spectra of K9 glass at sub-damage site by ultraviolet laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z., E-mail: namezhangzhen@126.com [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Huang, J.; Geng, F.; Zhou, X.Y. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Feng, S.Q. [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Cheng, X.L., E-mail: chengxl@scu.edu.cn [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Jiang, X.D. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Wu, W.D. [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Zheng, W.G.; Tang, Y.J. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China)

    2014-01-01

    Highlights: • Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. • As the energy density increases to 2.54 J/cm{sup 2}, the absorption intensity reaches to about 0.2. • The mechanism of two-photon ionization mainly plays a critical role at sub-damage site. • Intensity of Raman spectra is very high at low energy density and decreased with respect to high energy density. -- Abstract: Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. The dependence of transient absorption on laser energy and number of pulses was investigated. As the energy density increases to 2.54 and 3.18 J/cm{sup 2}, the transient absorption intensity reaches to about 0.20 range from 400 to 480 nm. With the increase of number of pulses the process of residual absorption appears, which can be used to explain the fatigue effect of K9 glass. The defects in K9 glass were investigated by fluorescence and Raman spectra. The fluorescence band centered at about 410 nm is attributed to oxygen deficiency centers. The mechanism of two-photon ionization plays a critical role at sub-damage site. Compared to the Raman spectra of pristine site, intensity of Raman spectra is very high at a lower energy density, while it decreased at a higher energy density.

  17. Infrared cross-sections and integrated band intensities of propylene: Temperature-dependent studies

    KAUST Repository

    Es-sebbar, Et-touhami

    2014-01-01

    Propylene, a by-product of biomass burning, thermal cracking of hydrocarbons and incomplete combustion of fossil fuels, is a ubiquitous molecule found in the environment and atmosphere. Accurate infrared (IR) cross-sections and integrated band intensities of propylene are essential for quantitative measurements and atmospheric modeling. We measured absolute IR cross-sections of propylene using Fourier Transform Infrared (FTIR) Spectroscopy over the wavenumber range of 400-6500cm-1 and at gas temperatures between 296 and 460K. We recorded these spectra at spectral resolutions ranging from 0.08 to 0.5cm-1 and measured the integrated band intensities for a number of vibrational bands in certain spectral regions. We then compared the integrated band intensities measured at room temperature with values derived from the National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) databases. Our results agreed well with the results reported in the two databases with a maximum deviation of about 4%. The peak cross-sections for the primary bands decreased by about 20-54% when the temperature increased from 296 to 460K. Moreover, we determined the integrated band intensities as a function of temperature for certain features in various spectral regions; we found no significant temperature dependence over the range of temperatures considered here. We also studied the effect of temperature on absorption cross-section using a Difference Frequency Generation (DFG) laser system. We compared the DFG results with those obtained from the FTIR study at certain wavenumbers over the 2850-2975cm-1 range and found a reasonable agreement with less than 10% discrepancy. © 2013 Elsevier Ltd.

  18. Spectral band selection for classification of soil organic matter content

    Science.gov (United States)

    Henderson, Tracey L.; Szilagyi, Andrea; Baumgardner, Marion F.; Chen, Chih-Chien Thomas; Landgrebe, David A.

    1989-01-01

    This paper describes the spectral-band-selection (SBS) algorithm of Chen and Landgrebe (1987, 1988, and 1989) and uses the algorithm to classify the organic matter content in the earth's surface soil. The effectiveness of the algorithm was evaluated comparing the results of classification of the soil organic matter using SBS bands with those obtained using Landsat MSS bands and TM bands, showing that the algorithm was successful in finding important spectral bands for classification of organic matter content. Using the calculated bands, the probabilities of correct classification for climate-stratified data were found to range from 0.910 to 0.980.

  19. Atmospheric pressure and temperature profiling using near IR differential absorption lidar

    Science.gov (United States)

    Korb, C. L.; Schwemmer, G. K.; Dombrowski, M.; Weng, C. Y.

    1983-01-01

    The present investigation is concerned with differential absorption lidar techniques for remotely measuring the atmospheric temperature and pressure profile, surface pressure, and cloud top pressure-height. The procedure used in determining the pressure is based on the conduction of high-resolution measurements of absorption in the wings of lines in the oxygen A band. Absorption with respect to these areas is highly pressure sensitive in connection with the mechanism of collisional line broadening. The method of temperature measurement utilizes a determination of the absorption at the center of a selected line in the oxygen A band which originates from a quantum state with high ground state energy.

  20. Photonic band gap materials

    Science.gov (United States)

    Cassagne, D.

    Photonic band gap materials Photonic band gap materials are periodic dielectric structures that control the propagation of electromagnetic waves. We describe the plane wave method, which allows to calculate the band structures of photonic crystals. By symmetry analysis and a perturbative approach, we predict the appearance of the low energy photonic band gaps of hexagonal structures. We propose new two-dimensional structures called graphite and boron nitride. Using a transfer matrix method, we calculate the transmission of the graphite structure and we show the crucial role of the coupling with external modes. We study the appearance of allowed modes in the photonic band gap by the introduction of localized defects in the periodicity. Finally, we discuss the properties of opals formed by self-organized silica microspheres, which are very promising for the fabrication of three-dimensional photonic crystals. Les matériaux à bandes interdites photoniques sont des structures diélectriques périodiques qui contrôlent la propagation des ondes électromagnétiques. Nous décrivons la méthode des ondes planes qui permet de calculer les structures de bandes des cristaux photoniques. Par une analyse de la symétrie et une approche perturbative, nous précisons les conditions d'existence des bandes interdites de basse énergie. Nous proposons de nouvelles structures bidimensionnelles appelées graphite et nitrure de bore. Grâce à une méthode de matrices de transfert, nous calculons la transmission de la structure graphite et nous mettons en évidence le rôle fondamental du couplage avec les modes extérieurs. Nous étudions l'apparition de modes permis dans la bande interdite grâce à l'introduction de défauts dans la périodicité. Enfin, nous discutons les propriétés des opales constituées de micro-billes de silice auto-organisées, qui sont très prometteuses pour la fabrication de cristaux photoniques tridimensionnels.

  1. Photodetector with enhanced light absorption

    Science.gov (United States)

    Kane, James

    1985-01-01

    A photodetector including a light transmissive electrically conducting layer having a textured surface with a semiconductor body thereon. This layer traps incident light thereby enhancing the absorption of light by the semiconductor body. A photodetector comprising a textured light transmissive electrically conducting layer of SnO.sub.2 and a body of hydrogenated amorphous silicon has a conversion efficiency about fifty percent greater than that of comparative cells. The invention also includes a method of fabricating the photodetector of the invention.

  2. Dual-band absorber for multispectral plasmon-enhanced infrared photodetection

    International Nuclear Information System (INIS)

    Yu, Peng; Ashalley, Eric; Wang, Zhiming; Wu, Jiang; Govorov, Alexander

    2016-01-01

    For most of the reported metamaterial absorbers, the peak absorption only occurs at one single wavelength. Here, we investigated a dual-band absorber which is based on simple gold nano-rings. Two absorption peaks can be readily achieved in 3–5 µ m and 8–14 µ m via tuning the width and radius of gold nano-rings and dielectric constant. The average maximum absorption of two bands can be as high as 95.1% (−0.22 dB). Based on the simulation results, the perfect absorber with nano-rings demonstrates great flexibility to create dual-band or triple-band absorption, and thus holds potential for further applications in thermophotovoltaics, multicolor infrared focal plane arrays, optical filters, and biological sensing applications. (paper)

  3. Restrictive techniques: gastric banding

    Directory of Open Access Journals (Sweden)

    Katia Cristina da Cunha

    2006-03-01

    Full Text Available Surgery for the treatment of severe obesity has a definite role onthe therapeutic armamentarium all over the world. Initiated 40years ago, bariatric surgery has already a long way thanks tohundred of surgeons, who had constantly searched for the besttechnique for the adequate control of severe obesity. Among theimportant breakthroughs in obesity surgery there is theadjustable gastric band. It is a sylastic band, inflatable andadjustable, which is placed on the top of the stomach in order tocreate a 15-20 cc pouch, with an outlet of 1.3cm. The adjustablegastric band has also a subcutaneous reservoir through whichadjustments can be made, according to the patient evolution.The main feature of the adjustable gastric band is the fact thatis minimal invasive, reversible, adjustable and placedlaparoscopically. Then greatly diminishing the surgical traumato the severe obese patient. Belachew and Favretti’s techniqueof laparoscopic application of the adjustable gastric band isdescribed and the evolution of the technique during this years,as we has been practiced since 1998. The perioperative care ofthe patient is also described, as well as the follow-up and shortand long term controls.

  4. Radio Band Observations of Blazar Variability Margo F. Aller , Hugh ...

    Indian Academy of Sciences (India)

    In this review we discuss the properties of centimeter-to-millimeter band variability in Stokes I (total flux density), and compare the derived values to those deter- mined in the Fermi γ-ray band. We summarize evidence for the shock-in-jet model invoked for explaining the optical-to-radio-band variations, and present new mod ...

  5. CO concentration and temperature sensor for combustion gases using quantum-cascade laser absorption near 4.7 μm

    KAUST Repository

    Ren, Wei

    2012-05-25

    A sensor for sensitive in situ measurements of carbon monoxide and temperature in combustion gases has been developed using absorption transitions in the (v′ = 1 ← v″ = 0) and (v′ = 2 ← v″ = 1) fundamental bands of CO. Recent availability of mid-infrared quantum-cascade (QC) lasers provides convenient access to the CO fundamental band near 4.7 μm, having approximately 104 and 102 times stronger absorption line-strengths compared to the overtone bands near 1.55 μm and 2.3 μm used previously to sense CO in combustion gases. Spectroscopic parameters of the selected transitions were determined via laboratory measurements in a shock tube over the 1100-2000 K range and also at room temperature. A single-laser absorption sensor was developed for accurate CO measurements in shock-heated gases by scanning the line pair v″ = 0, R(12) and v″ = 1, R(21) at 2.5 kHz. To capture the rapidly varying CO time-histories in chemical reactions, two different QC lasers were then used to probe the line-center absorbance of transitions v″ = 0, P(20) and v″ = 1, R(21) with a bandwidth of 1 MHz using fixed-wavelength direct absorption. The sensor was applied in successful shock tube measurements of temperature and CO time-histories during the pyrolysis and oxidation of methyl formate, illustrating the capability of this sensor for chemical kinetic studies. © 2012 Springer-Verlag.

  6. Assignment of FUT8 to chicken chromosome band 5q1.4 and to human chromosome 14q23.2-->q24.1 by in situ hybridization. Conserved and compared synteny between human and chicken

    NARCIS (Netherlands)

    Coullin, Ph.; Crooijmans, R.P.M.A.; Groenen, M.A.M.; Heilig, R.; Mollicone, R.; Oriol, R.; Candelier, J.J.

    2002-01-01

    The human FUT8 gene is implicated in crucial developmental stages and is overexpressed in some tumors and other malignant diseases. Based on three different experiments we have assigned the FUT8 gene to chromosome bands 14q23.2 --> q24.1 and not 14q24.3 as previously shown (Yamaguchi et al.,

  7. UV-Vis absorption spectra and electronic structure of merocyanines in the gas phase

    Science.gov (United States)

    Ishchenko, Alexander A.; Kulinich, Andrii V.; Bondarev, Stanislav L.; Raichenok, Tamara F.

    2018-02-01

    Gas-phase absorption spectra of a merocyanine vinylogous series have been studied for the first time. In vapour, their long-wavelength absorption bands were found to be considerably shifted hypsochromically, broader, more symmetrical, less intense, and their vinylene shift much smaller than even in low-polarity n-hexane. This indicates that in the gas phase their electronic structure closely approaches the nonpolar polyene limiting structure. The TDDFT calculations of the long-wavelength electronic transitions in the studied merocyanines in vacuo demonstrated good-to-excellent correlation - depending on the functional used - with the obtained experimental data. For comparison, the solvent effects was accounted for using the polarizable continuum model (PCM) with n-hexane and ethanol as low-polarity and high-polarity media, and compared with the UV-Vis spectral data in these solvents. In this case, the discrepancy between theory and experiment was much greater, increasing at that with the polymethine chain length.

  8. Short optical pulse generation at 40 GHz with a bulk electro-absorption modulator packaged device

    Science.gov (United States)

    Langlois, Patrick; Moore, Ronald; Prosyk, Kelvin; O'Keefe, Sean; Oosterom, Jill A.; Betty, Ian; Foster, Robert; Greenspan, Jonathan; Singh, Priti

    2003-12-01

    Short optical pulse generation at 40GHz and 1540nm wavelength is achieved using fully packaged bulk quaternary electro-absorption modulator modules. Experimental results obtained with broadband and narrowband optimized packaged modules are presented and compared against empirical model predictions. Pulse duty cycle, extinction ratio and chirp are studied as a function of sinusoidal drive voltage and detuning between operating wavelength and modulator absorption band edge. Design rules and performance trade-offs are discussed. Low-chirp pulses with a FWHM of ~12ps and sub-4ps at a rate of 40GHz are demonstrated. Optical time-domain demultiplexing of a 40GHz to a 10GHz pulse train is also demonstrated with better than 20dB extinction ratio.

  9. Surface-enhanced infrared absorption studies towards a new optical biosensor

    Directory of Open Access Journals (Sweden)

    Lothar Leidner

    2016-11-01

    Full Text Available Reflectometric interference spectroscopy (RIfS, which is well-established in the visual regime, measures the optical thickness change of a sensitive layer caused, e.g., by binding an analyte. When operated in the mid-infrared range the sensor provides additional information via weak absorption spectra (fingerprints. The originally poor spectra are magnified by surface-enhanced infrared absorption (SEIRA. This is demonstrated using the broad complex fluid water band at 3300 cm−1, which is caused by superposition of symmetric, antisymmetric stretching vibration, and the first overtone of the bending vibration under the influence of H-bonds and Fermi resonance effect. The results are compared with a similar experiment performed with an ATR (attenuated total reflectance set-up.

  10. Experimental determination of the absolute infrared absorption intensities of formyl radical HCO.

    Science.gov (United States)

    Ryazantsev, Sergey V; Tyurin, Daniil A; Feldman, Vladimir I

    2017-12-05

    Formyl radical HCO is an important reactive intermediate in combustion, atmospheric and extraterrestrial chemistry. Like in the case of other transients, the lack of knowledge of the absolute IR intensities limits the quantitative spectroscopic studies on this species. We report the first experimental determination of the absorption intensities for the fundamental vibrational bands of HCO. The measurements have been performed using matrix-isolation FTIR spectroscopy. Determination of the values was based on the repeated photodissociation and thermal recovery of the HCO radical using the known value of the absorption coefficient of CO. The experimentally determined values (93.2±6.0, 67.2±4.5, and 109.2±6.6kmmol -1 for the ν 1 , ν 2 , and ν 3 modes, respectively) have been compared to the calculated IR intensities obtained by DFT and UCCSD(T) computations. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Band gap tuning of amorphous Al oxides by Zr alloying

    DEFF Research Database (Denmark)

    Canulescu, Stela; Jones, N. C.; Borca, C. N.

    2016-01-01

    The optical band gap and electronic structure of amorphous Al-Zr mixed oxides, with Zr content ranging from4.8 to 21.9% were determined using vacuum ultraviolet (VUV) and X-ray absorption spectroscopy (XAS). Thelight scattering by the nano-porous structure of alumina at low wavelengths was estima...

  12. Effect of conduction band nonparabolicity on the optical properties in ...

    Indian Academy of Sciences (India)

    The effect of conduction band nonparabolicity on the linear and nonlinear optical properties such as absorption coefficients, and changes in the refractive index are calculated in the Al0.3Ga0.7As/GaAs heterostructure-based symmetric rectangular quantum well under applied hydrostatic pressure and electric field.

  13. Effect of conduction band nonparabolicity on the optical properties in ...

    Indian Academy of Sciences (India)

    Abstract. The effect of conduction band nonparabolicity on the linear and nonlinear optical properties such as absorption coefficients, and changes in the refractive index are calculated in the Al0.3Ga0.7As/GaAs heterostructure-based symmetric rectangular quantum well under applied hydrostatic pressure and electric field.

  14. Non-equilibrium and band tailing in organic conductors

    Indian Academy of Sciences (India)

    The concept of band tailing with focal point and width of the tail from IR absorption spectra of different organic conductors is found valid even for thermal and elastic changes. The experimental situations like change of solvents, method of preparation, applied pressure and pressure cycle apart from compositions is analyzed ...

  15. Absorption of controlled-release iron

    International Nuclear Information System (INIS)

    Cook, J.D.; Lipschitz, D.A.; Skikne, B.S.

    1982-01-01

    A multiple-dose double radioiron technic was used to compare absorption of iron administered as a controlled release (CR) capsule and as an elixir; both formulations contained 50 mg elemental iron as ferrous sulfate. When taken by normal subjects in the fasting state, mean absorption from the elixir and CR capsule averaged 4.92% and 4.38%, which gave a CR capsule:elixir ratio of 0.89. This difference was not significant, but when taken with meals that inhibit absorption of dietary iron by different degrees, absorption of the CR formulation was superior. CR capsule:elixir absorption ratios averaged 1.70 from a meal that is mildly inhibitory and 3.13 from a meal that causes more marked inhibition. It is concluded that CR iron formulations may offer a therapeutic advantage to patients who take oral iron with meals to avoid gastrointestinal side effects

  16. Absolute linestrengths in the H2O2 nu6 band

    Science.gov (United States)

    May, Randy D.

    1991-01-01

    Absolute linestrengths at 295 K have been measured for selected lines in the nu6 band of H2O2 using a tunable diode-laser spectrometer. H2O2 concentrations in a flowing gas mixture were determined by ultraviolet (uv) absorption at 254 nm using a collinear infrared (ir) and uv optical arrangement. The measured linestrengths are approx. 60 percent larger than previously reported values when absorption by hot bands in H2O2 is taken into account.

  17. Atmospheric Airborne Pressure Measurements Using the Oxygen A Band for the ASCENDS Mission

    Science.gov (United States)

    Riris, Haris; Rodriguez, Mike; Stephen, Mark; Hasselbrack, William; Allan, Graham; Mao, Jiamping,; Kawa, Stephan R.; Weaver, Clark J.

    2011-01-01

    We report on airborne atmospheric pressure measurements using new fiber-based laser technology and the oxygen A-band at 765 nm. Remote measurements of atmospheric temperature and pressure are required for a number of NASA Earth science missions and specifically for the Active Sensing of CO2 Emissions Over Nights, Days, and Seasons (ASCENDS) mission. Accurate measurements of tropospheric CO2 on a global scale are very important in order to better understand its sources and sinks and to improve predictions on any future climate change. The ultimate goal of a CO2 remote sensing mission, such as ASCENDS, is to derive the CO2 concentration in the atmosphere in terms of mole fraction in unit of parts-per-million (ppmv) with regard to dry air. Therefore, both CO2 and the dry air number of molecules in the atmosphere are needed in deriving this quantity. O2 is a stable molecule and uniformly mixed in the atmosphere. Measuring the O2 absorption in the atmosphere can thus be used to infer the dry air number of molecules and then used to calculate CO2 concentration. With the knowledge of atmospheric water vapor, we can then estimate the total surface pressure needed for CO2 retrievals. Our work, funded by the ESTO IIP program, uses fiber optic technology and non-linear optics to generate 765 nm laser radiation coincident with the Oxygen A-band. Our pulsed, time gated technique uses several on- and off-line wavelengths tuned to the O2 absorption line. The choice of wavelengths allows us to measure the pressure by using two adjacent O2 absorptions in the Oxygen A-band. Our retrieval algorithm fits the O2 lineshapes and derives the pressure. Our measurements compare favorably with a local weather monitor mounted outside our laboratory and a local weather station.

  18. Impact of line parameter database and continuum absorption on GOSAT TIR methane retrieval

    Science.gov (United States)

    Yamada, A.; Saitoh, N.; Nonogaki, R.; Imasu, R.; Shiomi, K.; Kuze, A.

    2017-12-01

    The current methane retrieval algorithm (V1) at wavenumber range from 1210 cm-1 to 1360 cm-1 including CH4 ν 4 band from the thermal infrared (TIR) band of Thermal and Near-infrared Sensor for Carbon Observation Fourier Transform Spectrometer (TANSO-FTS) onboard Greenhouse Gases Observing Satellite (GOSAT) uses LBLRTM V12.1 with AER V3.1 line database and MT CKD 2.5.2 continuum absorption model to calculate optical depth. Since line parameter databases have been updated and the continuum absorption may have large uncertainty, the purpose of this study is to assess the impact on {CH}4 retrieval from the choice of line parameter databases and the uncertainty of continuum absorption. We retrieved {CH}4 profiles with replacement of line parameter database from AER V3.1 to AER v1.0, HITRAN 2004, HITRAN 2008, AER V3.2, or HITRAN 2012 (Rothman et al. 2005, 2009, and 2013. Clough et al., 2005), we assumed 10% larger continuum absorption coefficients and 50% larger temperature dependent coefficient of continuum absorption based on the report by Paynter and Ramaswamy (2014). We compared the retrieved CH4 with the HIPPO CH4 observation (Wofsy et al., 2012). The difference from HIPPO observation of AER V3.2 was the smallest and 24.1 ± 45.9 ppbv. The differences of AER V1.0, HITRAN 2004, HITRAN 2008, and HITRAN 2012 were 35.6 ± 46.5 ppbv, 37.6 ± 46.3 ppbv, 32.1 ± 46.1 ppbv, and 35.2 ± 46.0 ppbv, respectively. Maximum {CH}4 retrieval differences were -0.4 ppbv at the layer of 314 hPa when we used 10% larger absorption coefficients of {H}2O foreign continuum. Comparing AER V3.2 case to HITRAN 2008 case, the line coupling effect reduced difference by 8.0 ppbv. Line coupling effects were important for GOSAT TIR {CH}4 retrieval. Effects from the uncertainty of continuum absorption were negligible small for GOSAT TIR CH4 retrieval.

  19. Ultra wide band antennas

    CERN Document Server

    Begaud, Xavier

    2013-01-01

    Ultra Wide Band Technology (UWB) has reached a level of maturity that allows us to offer wireless links with either high or low data rates. These wireless links are frequently associated with a location capability for which ultimate accuracy varies with the inverse of the frequency bandwidth. Using time or frequency domain waveforms, they are currently the subject of international standards facilitating their commercial implementation. Drawing up a complete state of the art, Ultra Wide Band Antennas is aimed at students, engineers and researchers and presents a summary of internationally recog

  20. Absorptive capacity and smart companies

    Directory of Open Access Journals (Sweden)

    Patricia Moro González

    2014-12-01

    Full Text Available Purpose: The current competitive environment is substantially modifying the organizations’ learning processes due to a global increase of available information allowing this to be transformed into knowledge. This opportunity has been exploited since the nineties by the tools of “Business Analytics” and “Business Intelligence” but, nevertheless, being integrated in the study of new organizational capacities engaged in the process of creating intelligence inside organizations is still an outstanding task. The review of the concept of absorptive capacity and a detailed study from the perspective of this new reality will be the main objective of study of this paper.Design/methodology/approach: By comparing classical absorptive capacity and absorptive capacity from the point of view of information management tools in each one of the three stages of the organizational learning cycle, some gaps of the former are overcome/fulfilled. The academic/bibliographical references provided in this paper have been obtained from ISI web of knowledge, Scopus and Dialnet data bases, supporting the state of affairs on absorptive capacity and thereafter filtering by "Business Intelligence" and "Business Analytics". Specialized websites and Business Schools` Publications there have also been included, crowning the content on information management tools used that are currently used in the strategic consulting.Findings: Our contribution to the literature is the development of "smart absorptive capacity". This is a new capacity emerging from the reformulation of the classical concept of absorptive capacity wherein some aspects of its definition that might have been omitted are emphasized. The result of this new approach is the creation of a new Theoretical Model of Organizational Intelligence, which aims to explain, within the framework of the Resources and Capabilities Theory, the competitive advantage achieved by the so-called smart companies

  1. Band-type microelectrodes for amperometric immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ga-Yeon; Chang, Young Wook; Ko, Hyuk [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of); Kang, Min-Jung [Korea Institute of Science and Technology (KIST), Seoul (Korea, Republic of); Pyun, Jae-Chul, E-mail: jcpyun@yonsei.ac.kr [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of)

    2016-07-20

    A band-type microelectrode was made using a parylene-N film as a passivation layer. A circular-type, mm-scale electrode with the same diameter as the band-type microelectrode was also made with an electrode area that was 5000 times larger than the band-type microelectrode. By comparing the amperometric signals of 3,5,3′,5′-tetramethylbenzidine (TMB) samples at different optical density (OD) values, the band-type microelectrode was determined to be 9 times more sensitive than the circular-type electrode. The properties of the circular-type and the band-type electrodes (e.g., the shape of their cyclic voltammograms, the type of diffusion layer used, and the diffusion layer thickness per unit electrode area) were characterized according to their electrode area using the COMSOL Multiphysics software. From these simulations, the band-type electrode was estimated to have the conventional microelectrode properties, even when the electrode area was 100 times larger than a conventional circular-type electrode. These results show that both the geometry and the area of an electrode can influence the properties of the electrode. Finally, amperometric analysis based on a band-type electrode was applied to commercial ELISA kits to analyze human hepatitis B surface antigen (hHBsAg) and human immunodeficiency virus (HIV) antibodies. - Highlights: • A band-type microelectrode was made using a parylene-N film as a passivation layer. • The band-type microelectrode was 14-times more sensitive than circular-type electrode. • The influence of geometry on microelectrode properties was simulated using COMSOL. • The band-type electrode was applied to ELISA kits for hHBsAg and hHIV-antibodies.

  2. S-Band Doppler Wave Radar System

    Directory of Open Access Journals (Sweden)

    Zezong Chen

    2017-12-01

    Full Text Available In this paper, a novel shore-based S-band microwave Doppler coherent wave radar (Microwave Ocean Remote SEnsor (MORSE is designed to improve wave measurements. Marine radars, which operate in the X band, have been widely used for ocean monitoring because of their low cost, small size and flexibility. However, because of the non-coherent measurements and strong absorption of X-band radio waves by rain, these radar systems suffer considerable performance loss in moist weather. Furthermore, frequent calibrations to modify the modulation transfer function are required. To overcome these shortcomings, MORSE, which operates in the S band, was developed by Wuhan University. Because of the coherent measurements of this sensor, it is able to measure the radial velocity of water particles via the Doppler effect. Then the relation between the velocity spectrum and wave height spectrum can be used to obtain the wave height spectra. Finally, wave parameters are estimated from the wave height spectra by the spectrum moment method. Comparisons between MORSE and Waverider MKIII are conducted in this study, and the results, including the non-directional wave height spectra, significant wave height and average wave period, are calculated and displayed. The correlation coefficient of the significant wave height is larger than 0.9, whereas that of the average wave period is approximately 0.4, demonstrating the effectiveness of MORSE for the continuous monitoring of ocean areas with high accuracy.

  3. A microscopic description of sound absorption in the atmosphere

    Science.gov (United States)

    Bass, H. E.

    1976-01-01

    The various mechanisms which contribute to sound absorption in the atmosphere are identified and a technique for computing the contribution from each is presented. The similarities between sound absorption, laser fluorescence measurements, and the opto-acoustic effect are discussed. Finally, experimental sound absorption results are compared to predictions to test the microscopic energy transfer approach.

  4. Lossless compression of hyperspectral images using C-DPCM-APL with reference bands selection

    Science.gov (United States)

    Wang, Keyan; Liao, Huilin; Li, Yunsong; Zhang, Shanshan; Wu, Xianyun

    2014-05-01

    The availability of hyperspectral images has increased in recent years, which is used in military and civilian applications, such as target recognition, surveillance, geological mapping and environmental monitoring. Because of its abundant data quantity and special importance, now it exists lossless compression methods of hyperspectral images mainly exploiting the strong spatial or spectral correlation. C-DPCM-APL is a method that achieves highest lossless compression ratio on the CCSDS hyperspectral images acquired in 2006 but consuming longest processing time among existing lossless compression methods to determine the optimal prediction length for each band. C-DPCM-APL gets best compression performance mainly via using optimal prediction length but ignoring the correlationship between reference bands and the current band which is a crucial factor that influences the precision of prediction. Considering this, we propose a method that selects reference bands according to the atmospheric absorption characteristic of hyperspectral images. Experiments on CCSDS 2006 images data set show that the proposed reduces the computation complexity heavily without decaying its lossless compression performance when compared to C-DPCM-APL.

  5. Graded band-gap engineering for increased efficiency in CZTS solar cells

    Science.gov (United States)

    Ferhati, H.; Djeffal, F.

    2018-02-01

    In this paper, we propose a potential high efficiency Cu2ZnSn(S,Se)4/CdS (CZTS) solar cell design based on graded band-gap engineering that can offer the benefits of improved absorption behavior and reduced recombination effects. Moreover, a new hybrid approach based on analytical modeling and Particle Swarm Optimization (PSO) is proposed to determinate the optimal band-gap profile of the amended CZTS absorber layer to achieve further efficiency enhancement. It is found that the proposed design exhibits superior performance, where a high efficiency of 16.9% is recorded for the optimized solar cell with a relative improvement of 92%, compared with the reference cell efficiency of 8.8%. Likewise, the optimized CZTS solar cell with a graded band-gap enables achieving a higher open circuit voltage of 889 mV, a short-circuit current of 28.5 mA and a fill factor of 66%. Therefore, the optimized CZTS-based solar cell with graded-band gap paradigm pinpoints a new path toward recording high-efficiency thin-film solar cells through enhancing carrier collection and reducing the recombination rate.

  6. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning......Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...

  7. Absorption fluids data survey

    Science.gov (United States)

    Macriss, R. A.; Zawacki, T. S.

    Development of improved data for the thermodynamic, transport and physical properties of absorption fluids were studied. A specific objective of this phase of the study is to compile, catalog and coarse screen the available US data of known absorption fluid systems and publish it as a first edition document to be distributed to manufacturers, researchers and others active in absorption heat pump activities. The methodology and findings of the compilation, cataloguing and coarse screening of the available US data on absorption fluid properties and presents current status and future work on this project are summarized. Both in house file and literature searches were undertaken to obtain available US publications with pertinent physical, thermodynamic and transport properties data for absorption fluids. Cross checks of literature searches were also made, using available published bibliographies and literature review articles, to eliminate secondary sources for the data and include only original sources and manuscripts. The properties of these fluids relate to the liquid and/or vapor state, as encountered in normal operation of absorption equipment employing such fluids, and to the crystallization boundary of the liquid phase, where applicable. The actual data were systematically classified according to the type of fluid and property, as well as temperature, pressure and concentration ranges over which data were available. Data were sought for 14 different properties: Vapor-Liquid Equilibria, Crystallization Temperature, Corrosion Characteristics, Heat of Mixing, Liquid-Phase-Densities, Vapor-Liquid-Phase Enthalpies, Specific Heat, Stability, Viscosity, Mass Transfer Rate, Heat Transfer Rate, Thermal Conductivity, Flammability, and Toxicity.

  8. Measurement of atmospheric precipitable water using a solar radiometer. [water vapor absorption effects

    Science.gov (United States)

    Pitts, D. E.; Dillinger, A. E.; Mcallum, W. E.

    1974-01-01

    A technique is described and tested that allows the determination of atmospheric precipitable water from two measurements of solar intensity: one in a water-vapor absorption band and another in a nearby spectral region unaffected by water vapor.

  9. A Polarization-Dependent Frequency-Selective Metamaterial Absorber with Multiple Absorption Peaks

    Directory of Open Access Journals (Sweden)

    Guangsheng Deng

    2017-06-01

    Full Text Available A polarization-dependent, frequency-selective metamaterial (MM absorber based on a single-layer patterned resonant structure intended for F frequency band is proposed. The design, fabrication, and measurement for the proposed absorber are presented. The absorber’s absorption properties at resonant frequencies have unique characteristics of a single-band, dual-band, or triple-band absorption for different polarization of the incident wave. The calculated surface current distributions and power loss distribution provide further understanding of physical mechanism of resonance absorption. Moreover, a high absorption for a wide range of TE-polarized oblique incidence was achieved. Hence, the MM structure realized on a highly flexible polyimide film, makingthe absorber suitable for conformal geometry applications. The proposed absorber has great potential in the development of polarization detectors and polarizers.

  10. Absorption cooling device. Absorptions-Kuehlvorrichtung

    Energy Technology Data Exchange (ETDEWEB)

    Bourne, J.; Vardi, I.; Kimchi, Y.; Ben-Dror, J.

    1980-03-25

    The invention concerns improvements of absorption refrigerators, where a lithium chloride or lithium bromide/water cycle is used. According to the invention an inner separating or dividing structure between different functional parts of a machine of this type is provided. The structure contains two sections of wall, which are separated from one another by a suitable space, in order to achieve thermal insulation. This air space is provided with an opening in the direction towards the inside of the container and the opening is shielded to prevent the entry of liquids (in liquid or spray form).

  11. Band-notched spiral antenna

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jae; Chang, John

    2018-03-13

    A band-notched spiral antenna having one or more spiral arms extending from a radially inner end to a radially outer end for transmitting or receiving electromagnetic radiation over a frequency range, and one or more resonance structures positioned adjacent one or more segments of the spiral arm associated with a notch frequency band or bands of the frequency range so as to resonate and suppress the transmission or reception of electromagnetic radiation over said notch frequency band or bands.

  12. Temperature dependent absorption spectra of Br(-), Br2(•-), and Br3(-) in aqueous solutions.

    Science.gov (United States)

    Lin, Mingzhang; Archirel, Pierre; Van-Oanh, Nguyen Thi; Muroya, Yusa; Fu, Haiying; Yan, Yu; Nagaishi, Ryuji; Kumagai, Yuta; Katsumura, Yosuke; Mostafavi, Mehran

    2011-05-05

    The absorption spectra of Br(2)(•-) and Br(3)(-) in aqueous solutions are investigated by pulse radiolysis techniques from room temperature to 380 and 350 °C, respectively. Br(2)(•-) can be observed even in supercritical conditions, showing that this species could be used as a probe in pulse radiolysis at high temperature and even under supercritical conditions. The weak temperature effect on the absorption spectra of Br(2)(•-) and Br(3)(-) is because, in these two systems, the transition occurs between two valence states; for example, for Br(2)(-) we have (2)Σ(u) → (2)Σ(g) transition. These valence transitions involve no diffuse final state. However, the absorption band of Br(-) undergoes an important red shift to longer wavelengths. We performed classical dynamics of hydrated Br(-) system at 20 and 300 °C under pressure of 25 MPa. The radial distribution functions (rdf's) show that the strong temperature increase (from 20 to 300 °C) does not change the radius of the solvent first shell. On the other hand, it shifts dramatically (by 1 Å) the second maximum of the Br-O rdf and introduces much disorder. This shows that the first water shell is strongly bound to the anion whatever the temperature. The first two water shells form a cavity of a roughly spherical shape around the anion. By TDDFT method, we calculated the absorption spectra of hydrated Br(-) at two temperatures and we compared the results with the experimental data.

  13. Optical absorption of carbon-gold core-shell nanoparticles

    Science.gov (United States)

    Wang, Zhaolong; Quan, Xiaojun; Zhang, Zhuomin; Cheng, Ping

    2018-01-01

    In order to enhance the solar thermal energy conversion efficiency, we propose to use carbon-gold core-shell nanoparticles dispersed in liquid water. This work demonstrates theoretically that an absorbing carbon (C) core enclosed in a plasmonic gold (Au) nanoshell can enhance the absorption peak while broadening the absorption band; giving rise to a much higher solar absorption than most previously studied core-shell combinations. The exact Mie solution is used to evaluate the absorption efficiency factor of spherical nanoparticles in the wavelength region from 300 nm to 1100 nm as well as the electric field and power dissipation profiles inside the nanoparticles at specified wavelengths (mostly at the localized surface plasmon resonance wavelength). The field enhancement by the localized plasmons at the gold surfaces boosts the absorption of the carbon particle, resulting in a redshift of the absorption peak with increased peak height and bandwidth. In addition to spherical nanoparticles, we use the finite-difference time-domain method to calculate the absorption of cubic core-shell nanoparticles. Even stronger enhancement can be achieved with cubic C-Au core-shell structures due to the localized plasmonic resonances at the sharp edges of the Au shell. The solar absorption efficiency factor can exceed 1.5 in the spherical case and reach 2.3 in the cubic case with a shell thickness of 10 nm. Such broadband absorption enhancement is in great demand for solar thermal applications including steam generation.

  14. Saturable absorption in detonation nanodiamond dispersions

    Science.gov (United States)

    Vanyukov, Viatcheslav; Mikheev, Gennady; Mogileva, Tatyana; Puzyr, Alexey; Bondar, Vladimir; Lyashenko, Dmitry; Chuvilin, Andrey

    2017-07-01

    We report on a saturable absorption in aqueous dispersions of nanodiamonds with femtosecond laser pulse excitation at a wavelength of 795 nm. The open aperture Z-scan experiments reveal that in a wide range of nanodiamond particle sizes and concentrations, a light-induced increase of transmittance occurs. The transmittance increase originates from the saturation of light absorption and is associated with a light absorption at 1.5 eV by graphite and dimer chains (Pandey dimer chains). The obtained key nonlinear parameters of nanodiamond dispersions are compared with those of graphene and carbon nanotubes, which are widely used for the mode-locking.

  15. Grain size dependent optical band gap of CdI2 films

    Indian Academy of Sciences (India)

    The thermally evaporated stoichiometric CdI2 films show good -axis alignment normal to substrate plane for film thickness up to 200 nm. The optical absorption data indicate an allowed direct interband transition across a gap of 3.6 eV in confirmation with earlier band structure calculations. However, part of the absorption ...

  16. Intersubband light absorption by holes in InAsSb/AlSb quantum well heterostructures

    International Nuclear Information System (INIS)

    Pavlov, N V; Zegrya, G G

    2016-01-01

    The absorption coefficients of intersubband optical transitions in the valence band of the AlSb/InAs_0_._8_4Sb_0_._1_6/AlSb quantum wells in framework of the four-band Kane model. It is established that the light absorption by holes may lead to the laser generation breakdown. It is shown that we need to decrease the quantum well width to range a<6 nm to neutralize the negative influence of this effect. (paper)

  17. Temperature dependence of absorption spectra of P-type GaP

    International Nuclear Information System (INIS)

    Mounir, M.; Balloomal, L.S.

    1985-10-01

    The theoretical analysis of the optical absorption due to band-impurity (impurity-band) electron transitions involving deep impurity levels in semi-conductors is considered. Also the data of the experimental absorption spectra of GaP were performed at room temperature and the results were found to be in agreement with the theoretical results if the electron-phonon interaction is taken into consideration. (author)

  18. Microwave absorption studies of MgB2 superconductor

    Indian Academy of Sciences (India)

    band (9–. 10 GHz) spectrometer. Both polycrystalline pellet and single-grain MgB2, having nearly the same Tc (∼ 39 K) and same size (3×2×1 mm3), were used in the present investigations. Low field modulated microwave absorption signals ...

  19. EXACT DIAGONALIZATION RESULTS FOR MULTIMAGNON IR ABSORPTION IN THE CUPRATES

    NARCIS (Netherlands)

    Lorenzana, J.; Eder, R; Meinders, M.B J; Sawatzky, G.A

    1995-01-01

    Recent measured bands in the mid IR of parent insulating compounds of cuprate superconductors [Perkins et al. Phys. Rev. Lett. 71 1621 (1993)] are interpreted as multimagnon infrared (IR) absorption assisted by phonons. We present results for the coupling constant of light with this excitations and

  20. Optical absorption of copper met-myoglobin complexes

    International Nuclear Information System (INIS)

    Lamy, M.T.; Ribeiro, P.C.; Nascimento, O.R.; Bemski, G.

    1976-01-01

    It is reported on the use of a known denaturing agent, namely Cu 2+ ions, to induce a gradual change in the optical spectrum of Mb solutions, in order to identify the absorption bands that undergo similar changes which may be attributed to the transitions between correlated energy levels [pt

  1. Microwave absorption studies of MgB 2 superconductor

    Indian Academy of Sciences (India)

    Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. ... Radiochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India; Technical Physics and Prototype Engineering Division, Bhabha Atomic Research Centre, Mumbai 400 085, India ...

  2. Protonation Reaction of Benzonitrile Radical Anion and Absorption of Product

    DEFF Research Database (Denmark)

    Holcman, Jerzy; Sehested, Knud

    1975-01-01

    The rate constant for the protonation of benzonitrile radical anions formed in pulse radiolysis of aqueous benzonitrile solutions is (3.5 ± 0.5)× 1010 dm3 mol–1 s–1. A new 270 nm absorption band is attributed to the protonated benzonitrile anion. The pK of the protonation reaction is determined t...

  3. Theoretical Calculation and Validation of the Water Vapor Continuum Absorption

    Science.gov (United States)

    Ma, Qiancheng; Tipping, Richard H.

    1998-01-01

    The primary objective of this investigation is the development of an improved parameterization of the water vapor continuum absorption through the refinement and validation of our existing theoretical formalism. The chief advantage of our approach is the self-consistent, first principles, basis of the formalism which allows us to predict the frequency, temperature and pressure dependence of the continuum absorption as well as provide insights into the physical mechanisms responsible for the continuum absorption. Moreover, our approach is such that the calculated continuum absorption can be easily incorporated into satellite retrieval algorithms and climate models. Accurate determination of the water vapor continuum is essential for the next generation of retrieval algorithms which propose to use the combined constraints of multi-spectral measurements such as those under development for EOS data analysis (e.g., retrieval algorithms based on MODIS and AIRS measurements); current Pathfinder activities which seek to use the combined constraints of infrared and microwave (e.g., HIRS and MSU) measurements to improve temperature and water profile retrievals, and field campaigns which seek to reconcile spectrally-resolved and broad-band measurements such as those obtained as part of FIRE. Current widely used continuum treatments have been shown to produce spectrally dependent errors, with the magnitude of the error dependent on temperature and abundance which produces errors with a seasonal and latitude dependence. Translated into flux, current water vapor continuum parameterizations produce flux errors of order 10 W/ml, which compared to the 4 W/m' magnitude of the greenhouse gas forcing and the 1-2 W/m' estimated aerosol forcing is certainly climatologically significant and unacceptably large. While it is possible to tune the empirical formalisms, the paucity of laboratory measurements, especially at temperatures of interest for atmospheric applications, preclude tuning

  4. Adiabatic pressure dependence of the 2.7 and 1.9 micron water vapor bands

    Science.gov (United States)

    Mathai, C. V.; Walls, W. L.; Broersma, S.

    1977-01-01

    An acoustic excitation technique is used to determine the adiabatic pressure derivative of the spectral absorptance of the 2.7 and 1.9 micron water vapor bands, and the 3.5 micron HCl band. The dependence of this derivative on thermodynamic parameters such as temperature, concentration, and pressure is evaluated. A cross-flow water vapor system is used to measure spectral absorptance. Taking F as the ratio of nonrigid to rotor line strengths, it is found that an F factor correction is needed for the 2.7 micron band. The F factor for the 1.9 micron band is also determined. In the wings of each band a wavelength can be found where the concentration dependence is predominant. Farther out in the wings a local maximum occurs for the temperature derivative. It is suggested that the pressure derivative is significant in the core of the band.

  5. Band resolution of optical spectra of solvated electrons in water, alcohols, and tetrahydrofuran

    International Nuclear Information System (INIS)

    Jou, F.-Y.; Freeman, G.R.

    1979-01-01

    The optical absorption spectra of solvated electrons in water, alcohols, and tetrahydrofuran are empirically resolved into two Gaussian bands and a continuum tail. The first Gaussian band covers most of the low energy side of the spectrum. The second Gaussian band lies at an energy slightly above that of the absorption maximum of the total spectrum. With the exception of tert-butyl alcohol, in water and alcohols the following were observed: (a) the first Gaussian bands have the same half-width, but the oscillator strength in water is about double that in an alcohol; (b) the second Gaussian bands have similar half-widths and oscillator strengths; (c) the continuum tails have similar half-widths, yet that in water possesses only about one third as much oscillator strength as the one in alcohol. In tert-butyl alcohol and tetrahydrofuran the first Gaussian band and the continuum tail each carry nearly half of the total oscillator strength. (author)

  6. Intestinal Water Absorption Varies with Expected Dietary Water Load among Bats but Does Not Drive Paracellular Nutrient Absorption.

    Science.gov (United States)

    Price, Edwin R; Brun, Antonio; Gontero-Fourcade, Manuel; Fernández-Marinone, Guido; Cruz-Neto, Ariovaldo P; Karasov, William H; Caviedes-Vidal, Enrique

    2015-01-01

    Rapid absorption and elimination of dietary water should be particularly important to flying species and were predicted to vary with the water content of the natural diet. Additionally, high water absorption capacity was predicted to be associated with high paracellular nutrient absorption due to solvent drag. We compared the water absorption rates of sanguivorous, nectarivorous, frugivorous, and insectivorous bats in intestinal luminal perfusions. High water absorption rates were associated with high expected dietary water load but were not highly correlated with previously measured rates of (paracellular) arabinose clearance. In conjunction with these tests, we measured water absorption and the paracellular absorption of nutrients in the intestine and stomach of vampire bats using luminal perfusions to test the hypothesis that the unique elongated vampire stomach is a critical site of water absorption. Vampire bats' gastric water absorption was high compared to mice but not compared to their intestines. We therefore conclude that (1) dietary water content has influenced the evolution of intestinal water absorption capacity in bats, (2) solvent drag is not the only driver of paracellular nutrient absorption, and (3) the vampire stomach is a capable but not critical location for water absorption.

  7. Seasonal Solar Thermal Absorption Energy Storage Development.

    Science.gov (United States)

    Daguenet-Frick, Xavier; Gantenbein, Paul; Rommel, Mathias; Fumey, Benjamin; Weber, Robert; Gooneseker, Kanishka; Williamson, Tommy

    2015-01-01

    This article describes a thermochemical seasonal storage with emphasis on the development of a reaction zone for an absorption/desorption unit. The heat and mass exchanges are modelled and the design of a suitable reaction zone is explained. A tube bundle concept is retained for the heat and mass exchangers and the units are manufactured and commissioned. Furthermore, experimental results of both absorption and desorption processes are presented and the exchanged power is compared to the results of the simulations.

  8. Vitamin A absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Investigation of the absorption of vitamin A and related substances is complicated by the multiplicity of forms in which they occur in the diet and by the possibility that they may be subject to different mechanisms of absorption. Present knowledge of these mechanisms is inadequate, especially in the case of carotenoids. Numerous tests of absorption have been developed. The most common has been the biochemical measurement of the rise in plasma vitamin A after an oral dose of retinol or retinyl ester, but standardization is inadequate. Radioisotope tests based upon assay of serum or faecal activity following oral administration of tritiated vitamin A derivaties hold considerable promise, but again standardization is inadequate. From investigations hitherto performed it is known that absorption of vitamin A is influenced by several diseases, although as yet the consistency of results and the correlation with other tests of intestinal function have often been poor. However, the test of vitamin A absorption is nevertheless of clinical importance as a specialized measure of intestinal function. (author)

  9. Electronic band structure in porous silicon studied by photoluminescence and photoluminescence excitation spectroscopy

    International Nuclear Information System (INIS)

    Lee, Ki-Won; Kim, Young-You

    2004-01-01

    In this research, we used photoluminescence (PL) and photoluminescence excitation (PLE) to visualize the electronic band structure in porous silicon (PS). From the combined results of the PLE measurements at various PL emission energies and the PL measurements under excitation at various PLE absorption energies, we infer that three different electronic band structures, originating from different luminescent origins, give rise to the PL spectrum. Through either thermal activation or diffusive transfer, excited carriers are moved to each of the electronic band structures.

  10. Nonideal anion displacement, band gap variation, and valence band splitting in Cu-In-Se compounds

    International Nuclear Information System (INIS)

    Reena Philip, Rachel; Pradeep, B.

    2005-01-01

    Polycrystalline thin films of ternary chalcopyrite CuInSe 2 and defect compounds CuIn 3 Se 5 and CuIn 5 Se 8 are prepared in vacuum by three-source coevaporation method. Structural and optical characterizations of the films are done using X-ray diffraction (XRD), energy-dispersive X-ray analysis (EDAX), and optical absorbance spectra measurements. With variation in the composition of CuInSe 2 , a change over from p-type to n-type conductivity is observed (as noted by the hot probe method). The deformation parameters and the anion displacements are calculated from the X-ray diffraction data, and the cation-anion bond lengths are deduced. The dependence of band gap variation on nonideal anion displacement in the ternary compounds and the effect of Se-p-Cu-d repulsion on band gap are studied. The threefold optical structure observed in the fundamental absorption region of the absorption spectra is analysed to extract the valence band splitting parameters. Hopfields quasi-cubic model adapted for chalcopyrites with tetragonal deformation is used to determine the crystal field splittings and spin orbit splittings, and the linear hybridization model is used to calculate the percentage of d-orbital and p-orbital contribution to hybridization in the compounds under consideration

  11. Strongly correlated impurity band superconductivity in diamond: X-ray spectroscopic evidence

    Directory of Open Access Journals (Sweden)

    G. Baskaran

    2006-01-01

    Full Text Available In a recent X-ray absorption study in boron doped diamond, Nakamura et al. have seen a well isolated narrow boron impurity band in non-superconducting samples and an additional narrow band at the chemical potential in a superconducting sample. We interpret the beautiful spectra as evidence for upper Hubbard band of a Mott insulating impurity band and an additional metallic 'mid-gap band' of a conducting 'self-doped' Mott insulator. This supports the basic framework of a recent theory of the present author of strongly correlated impurity band superconductivity (impurity band resonating valence bond, IBRVB theory in a template of a wide-gap insulator, with no direct involvement of valence band states.

  12. A one-step conversion from gastric banding to laparoscopic Roux-en-Y gastric bypass is as safe as a two-step conversion: A comparative analysis of 885 patients.

    Science.gov (United States)

    Debergh, Isabelle; Defoort, Barbara; De Visschere, Marieke; Flahou, Silke; Van Cauwenberge, Sebastiaan; Mulier, Jan P; Dillemans, Bruno

    2016-10-01

    To achieve additional weight loss or to resolve band-related problems, a laparoscopic adjustable gastric banding (LAGB) can be converted to a laparoscopic Roux-en-Y gastric bypass (RYGB). There is limited data on the feasibility and safety of routinely performing a single-step conversion. We assessed the efficacy of this revisional approach in a large cohort of patients operated in a high-volume bariatric institution. Between October 2004 and December 2015, a total of 885 patients who underwent LAGB removal with RYGB were identified from a prospectively collected database. In all cases, a single-stage conversion procedure was planned. The feasibility of this approach and peri-operative outcomes of these patients were evaluated and analyzed. A single-step approach was successfully achieved in 738 (83.4%) of the 885 patients. During the study period, there was a significant increase in performing the conversion from LAGB to RYGB single-staged. No mortality or anastomotic leakage was observed in both groups. Only 45 patients (5.1%) had a 30-d complication: most commonly hemorrhage (N = 20/45), with no significant difference between the groups. Converting a LAGB to RYGB can be performed with a very low morbidity and zero-mortality in a high-volume revisional bariatric center. With increasing experience and full standardization of the conversion, the vast majority of operations can be performed as a single-stage procedure. Only a migrated band remains a formal contraindication for a one-step approach.

  13. Theoretical band alignment in an intermediate band chalcopyrite based material

    Science.gov (United States)

    Castellanos Águila, J. E.; Palacios, P.; Conesa, J. C.; Arriaga, J.; Wahnón, P.

    2017-12-01

    Band alignment is key to enhance the performance of heterojunction for chalcopyrite thin film solar cells. In this paper we report ab initio calculations of the electronic structures of CuGaS2:Cr with various Cr compositions, CuAlSe2 and ZnSe and the band alignment between their interfaces. We use density functional theory and the more accurate self-consistent GW scheme to obtain improved bulk band-gaps and band offsets. Band alignments of the interfacial region for CuGaS2:Cr/CuAlSe2 and CuGaS2:Cr/ZnSe systems were aligned with respect of an average electrostatic potential. Our results are in good agreement with experimental values for the bulk band-gaps. These theoretical band alignments show a characteristic staggered band alignment for the design of heterojunction devices in photovoltaic applications.

  14. Band structures in fractal grading porous phononic crystals

    Science.gov (United States)

    Wang, Kai; Liu, Ying; Liang, Tianshu; Wang, Bin

    2018-05-01

    In this paper, a new grading porous structure is introduced based on a Sierpinski triangle routine, and wave propagation in this fractal grading porous phononic crystal is investigated. The influences of fractal hierarchy and porosity on the band structures in fractal graidng porous phononic crystals are clarified. Vibration modes of unit cell at absolute band gap edges are given to manifest formation mechanism of absolute band gaps. The results show that absolute band gaps are easy to form in fractal structures comparatively to the normal ones with the same porosity. Structures with higher fractal hierarchies benefit multiple wider absolute band gaps. This work provides useful guidance in design of fractal porous phononic crystals.

  15. Airborne Lidar Measurements of Atmospheric Pressure Made Using the Oxygen A-Band

    Science.gov (United States)

    Riris, Haris; Rodriquez, Michael; Allan, Graham R.; Hasselbrack, William E.; Stephen, Mark A.; Abshire, James B.

    2011-01-01

    We report on airborne measurements of atmospheric pressure using a fiber-laser based lidar operating in the oxygen A-band near 765 nm and the integrated path differential absorption measurement technique. Our lidar uses fiber optic technology and non-linear optics to generate tunable laser radiation at 765 nm, which overlaps an absorption line pair in the Oxygen A-band. We use a pulsed time resolved technique, which rapidly steps the laser wavelength across the absorption line pair, a 20 cm telescope and photon counting detector to measure Oxygen concentrations.

  16. Gastrointestinal absorption of plutonium

    International Nuclear Information System (INIS)

    Larsen, R.P.; Oldham, R.D.; Bhattacharyya, M.H.; Moretti, E.S.; Austin, D.J.

    1981-01-01

    An investigation has been made of the effect of the oxidation state of plutonium on its absorption from the gastrointestinal tract. For mice and rats that have been starved prior to gastrointestinal administration, there is no significant difference between the absorption factors for Pu(IV) and Pu(VI). The value obtained for Pu(VI) is an order of magnitude lower than that reported previously. The value obtained for Pu(IV) is two orders of magnitude higher than those reported previously for nitrate solutions and the same as those reported for citrate solutions

  17. Quantum Absorption Refrigerator

    Science.gov (United States)

    Levy, Amikam; Kosloff, Ronnie

    2012-02-01

    A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold, and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified; the cooling power Jc vanishes as Jc∝Tcα, when Tc→0, where α=d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

  18. Obituary: David L. Band (1957-2009)

    Science.gov (United States)

    Cominsky, Lynn

    2011-12-01

    David L. Band, of Potomac Maryland, died on March 16, 2009 succumbing to a long battle with spinal cord cancer. His death at the age of 52 came as a shock to his many friends and colleagues in the physics and astronomy community. Band showed an early interest and exceptional aptitude for physics, leading to his acceptance at the Massachusetts Institute of Technology as an undergraduate student in 1975. After graduating from MIT with an undergraduate degree in Physics, Band continued as a graduate student in Physics at Harvard University. His emerging interest in Astrophysics led him to the Astronomy Department at the Harvard Smithsonian Center for Astrophysics (CfA), where he did his dissertation work with Jonathan Grindlay. His dissertation (1985) entitled "Non-thermal Radiation Mechanisms and Processes in SS433 and Active Galactic Nuclei" was "pioneering work on the physics of jets arising from black holes and models for their emission, including self-absorption, which previewed much to come, and even David's own later work on Gamma-ray Bursts," according to Grindlay who remained a personal friend and colleague of Band's. Following graduate school, Band held postdoctoral positions at the Lawrence Livermore Laboratory, the University of California at Berkeley and the Center for Astronomy and Space Sciences at the University of California San Diego where he worked on the BATSE experiment that was part of the Compton Gamma Ray Observatory (CGRO), launched in 1991. BATSE had as its main objective the study of cosmic gamma-ray bursts (GRBs) and made significant advances in this area of research. Band became a world-renowned figure in the emerging field of GRB studies. He is best known for his widely-used analytic form of gamma-ray burst spectra known as the "Band Function." After the CGRO mission ended, Band moved to the Los Alamos National Laboratory where he worked mainly on classified research but continued to work on GRB energetics and spectra. When NASA planned

  19. Nonequilibrium absorption in semiconductors and the dynamical Franz-Keldysh effect

    DEFF Research Database (Denmark)

    Johnsen, Kristinn; Jauho, Antti-Pekka

    1997-01-01

    We theoretically study free electron light absorption for a sample which is placed in a strong, time-dependent uniform electric field. In the case of static fields one observes the Franz-Keldysh effect: finite absorption for photon energies below the band gap. We refer to this phenomenon as the F...

  20. X-ray absorption spectroscopy of PbMoO 4 single crystals

    Indian Academy of Sciences (India)

    X-ray absorption spectra of PbMoO4 (LMO) crystals have been investigated for the first time in literature. The measurements have been carried out at Mo absorption edge at the dispersive EXAFS beamline (BL-8) of INDUS-2 Synchrotron facility at Indore, India. The optics of the beamline was set to obtain a band of 2000 eV ...

  1. The 890 nm Band of Methane

    Science.gov (United States)

    Spickler, Philip T.; Benner, D.; O'Brien, J.; Devi, V.; Shaji, S.; Houck, C.; Coakley, J.

    2010-01-01

    The near infrared bands of methane were the first observed in the outer planets and Titan. With the very long paths of rays in this spectral region within the atmospheres of these objects, scattering and pressure and temperature inhomogeneities are important. Here the spectrum is very complex and long absorption paths in the laboratory are difficult to cool to outer solar system temperatures. Many significant spectral lines appear per Doppler width, so the absorption is usually modeled statistically. The problem with these statistical models is that violations of the modeling assumptions can cause the extrapolation of laboratory parameters to predict absorption that diverges from the actual. These models generally do not provide transmissions that are multiplicative, so scattering and inhomogeneous atmospheres cannot be properly modeled. The intracavity laser spectrometer of the University of Missouri-St. Louis was used to obtain low temperature (99-161K), low pressure (0.12-7.13 Torr), long path (3.14-5.65 km) and high resolution ( 0.01 cm-1 HWHM) spectra of methane covering the entire 890nm feature (10925-11500 cm-1), the deepest band in the CCD spectral region. At these temperatures the spectral lines originating from higher energy levels are not visible and the Doppler width is decreased substantially from room temperature. The result is a dense, but manageable spectrum from which line positions, intensities and lower state energies are derived on a line by line basis by the William and Mary multispectrum nonlinear least squares fitting program, allowing for the simulation of the spectrum at infinite resolution for any physical conditions with temperature less than 160K. A sample spectrum will be shown. Support for work at William and Mary provided by NASA through grant NNX08AF06G. Support for work at UM-St. Louis provided by NASA through grant NAG5-12013, from NSF through grant CHE-0213356 and by the University of Missouri Research Board.

  2. Band Edge Dynamics and Multiexciton Generation in Narrow Band Gap HgTe Nanocrystals.

    Science.gov (United States)

    Livache, Clément; Goubet, Nicolas; Martinez, Bertille; Jagtap, Amardeep; Qu, Junling; Ithurria, Sandrine; Silly, Mathieu G; Dubertret, Benoit; Lhuillier, Emmanuel

    2018-04-02

    Mercury chalcogenide nanocrystals and especially HgTe appear as an interesting platform for the design of low cost mid-infrared (mid-IR) detectors. Nevertheless, their electronic structure and transport properties remain poorly understood, and some critical aspects such as the carrier relaxation dynamics at the band edge have been pushed under the rug. Some of the previous reports on dynamics are setup-limited, and all of them have been obtained using photon energy far above the band edge. These observations raise two main questions: (i) what are the carrier dynamics at the band edge and (ii) should we expect some additional effect (multiexciton generation (MEG)) as such narrow band gap materials are excited far above the band edge? To answer these questions, we developed a high-bandwidth setup that allows us to understand and compare the carrier dynamics resonantly pumped at the band edge in the mid-IR and far above the band edge. We demonstrate that fast (>50 MHz) photoresponse can be obtained even in the mid-IR and that MEG is occurring in HgTe nanocrystal arrays with a threshold around 3 times the band edge energy. Furthermore, the photoresponse can be effectively tuned in magnitude and sign using a phototransistor configuration.

  3. Photovoltaic properties of low band gap ferroelectric perovskite oxides

    Science.gov (United States)

    Huang, Xin; Paudel, Tula; Dong, Shuai; Tsymbal, Evgeny

    2015-03-01

    Low band gap ferroelectric perovskite oxides are promising for photovoltaic applications due to their high absorption in the visible optical spectrum and a possibility of having large open circuit voltage. Additionally, an intrinsic electric field present in these materials provides a bias for electron-hole separation without requiring p-n junctions as in conventional solar cells. High quality thin films of these compounds can be grown with atomic layer precision allowing control over surface and defect properties. Initial screening based on the electronic band gap and the energy dependent absorption coefficient calculated within density functional theory shows that hexagonal rare-earth manganites and ferrites are promising as photovoltaic absorbers. As a model, we consider hexagonal TbMnO3. This compound has almost ideal band gap of about 1.4 eV, very high ferroelectric Curie temperature, and can be grown epitaxially. Additionally hexagonal TbMnO3 offers possibility of coherent structure with transparent conductor ZnO. We find that the absorption is sufficiently high and dominated by interband transitions between the Mn d-bands. We will present the theoretically calculated photovoltaic efficiency of hexagonal TbMnO3 and explore other ferroelectric perovskite oxides.

  4. Effect of the bio-absorbent on the microwave absorption property of the flaky CIPs/rubber absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yang; Xu, Yonggang, E-mail: xuyonggang221@163.com; Cai, Jun; Yuan, Liming; Zhang, Deyuan

    2015-09-01

    Microwave absorbing composites filled with flaky carbonyl iron particles (CIPs) and the bio-absorbent were prepared by using a two-roll mixer and a vulcanizing machine. The electromagnetic (EM) parameters were measured by a vector network analyzer and the reflection loss (RL) was measured by the arch method in the frequency range of 1–4 GHz. The uniform dispersion of the absorbents was verified by comparing the calculated RL with the measured one. The results confirm that as the bio-absorbent was added, the permittivity was increased due to the volume content of absorbents, and the permeability was enlarged owing to the volume content of CIPs and interactions between the two absorbents. The composite filled with bio-absorbents achieved an excellent absorption property at a thickness of 1 mm (minimum RL reaches −7.8 dB), and as the RL was less than −10 dB the absorption band was widest (2.1–3.8 GHz) at a thickness of 2 mm. Therefore, the bio-absorbent is a promising additive candidate on fabricating microwave absorbing composites with a thinner thickness and wider absorption band. - Graphical abstract: Morphology of composites filled with flaky CIPs and the bio-absorbent. The enhancement of bio-absorbent on the electromagnetic absorption property of composites filled with flaky carbonyl iron particles (CIPs) is attributed to the interaction of the two absorbents. The volume content of the FCMPs with the larger shape CIPs play an important role in this effects, the composites filled with irons and bio-absorbents can achieve wider-band and thinner-thickness absorbing materials. - Highlights: • Absorbers filled with bio-absorbents and CIPs was fabricated. • Bio-absorbents enhanced the permittivity and permeability of the composites. • The absorbent interactions play a key role in the enhancement mechanism. • Bio-absorbents enhanced the composite RL in 1–4 GHz.

  5. Measurements of linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene in the ν4+ν5 combination band using a cw quantum cascade laser

    KAUST Repository

    Sajid, Muhammad Bilal

    2014-11-01

    Linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene have been measured at 296K in the P branch of the ν4+ν5 combination band for 25 rotational transitions. The effect of gas temperature is studied over 296-683K for five transitions to allow the determination of the temperature dependent exponent n for N2- and Ar-broadening coefficients. These measurements were performed using a continuous-wave quantum cascade laser (cw-QCL) operating over 1253-1310cm-1. Spectroscopic parameters were obtained by fitting absorption spectra using Voigt, Galatry and Rautian profiles. Linestrength and broadening results are compared with previous studies available in literature for the ν4+ν5 combination band and other vibrational bands of acetylene. © 2014 Elsevier Ltd.

  6. Simplified procedure for computing the absorption of sound by the atmosphere

    Science.gov (United States)

    2007-10-31

    This paper describes a study that resulted in the development of a simplified : method for calculating attenuation by atmospheric-absorption for wide-band : sounds analyzed by one-third octave-band filters. The new method [referred to : herein as the...

  7. X-ray Emission and Absorption Studies of Silicides in Relation to their Electronic Structure

    NARCIS (Netherlands)

    Weijs, P.J.W.; Wiech, G.; Zahorowski, W.; Speier, W.; Goedkoop, J.B.; Czyzyk, Marek; Acker, J.F. van; Leuken, E. van; Groot, R.A. de; Laan, G. van der; Sarma, D.D.; Kumar, L.; Buschow, K.H.J.; Fuggle, J.C.

    1990-01-01

    The valence bands and conduction bands of about 30 transition metal silicides (of which we concentrate on 4 here) have been investigated by measurements of Si X-ray emission bandsspectra, X-ray absorption spectra near the Si K (1s) edge, photoemission spectra, and Bremsstrahlung Isochromat spectra.

  8. Effects of neck bands on survival of greater snow geese

    Science.gov (United States)

    Menu, S.; Hestbeck, J.B.; Gauthier, G.; Reed, A.

    2000-01-01

    Neck bands are a widely used marker in goose research. However, few studies have investigated a possible negative effect of this marker on survival. We tested the effect of neck bands on the survival of adult female greater snow geese (Chen caerulescens atlantica) by marking birds with either a neck band and a metal leg band or a leg band only on Bylot Island (Nunavut, formerly included in the Northwest Territories, Canada) from 1990 to 1996. Annual survival was estimated using leg-band recoveries in fall and winter and using neck-band sightings in spring and fall. Recapture rates were estimated using summer recaptures. Using recovery data, the selected model yielded a survival similar for the neck-banded and leg-banded only birds (S = 0.845 ?? 0.070 vs. S = 0.811 ?? 0.107). The hypothesis of equality of survival between the 2 groups was easily accepted under most constraints imposed on survival or recovery rates. However, failure to account for a different direct recovery rate for neck-banded birds would lead us to incorrectly conclude a possible negative effect of neck bands on survival. Using sighting data, mean annual survival of neck-banded birds was independently estimated at 0.833 ?? 0.057, a value very similar to that estimated with band-recovery analysis. Raw recapture rates during summer were significantly lower for neck-banded birds compared to those marked with leg bands only (4.6% vs. 12.1%), but in this analysis, survival, site fidelity, reproductive status, and recapture rates were confounded. We conclude that neck bands did not affect survival of greater snow geese, but could possibly affect other demographic traits such as breeding propensity and emigration.

  9. Thermionic detection of the ionic fragments of continiuum-state pair absorption systems

    International Nuclear Information System (INIS)

    Hotop, R.; Niemax, K.; Richter, J.; Weber, K.H.

    1981-01-01

    Using a thermionic diode we have detected the ionic fragments formed by associative ionization and dissociation after continuum-state pair absorption processes in Cs-Cs and Cs-K systems. Assuming an ionization probability of unity of the excited species and calibrating the pair absorption bands by taking into account the known photoionization cross section of the atoms we found excellent agreement with data from classical absorption measurements. (orig.)

  10. Phytases for Improved Iron Absorption

    DEFF Research Database (Denmark)

    Nielsen, Anne Veller Friis; Nyffenegger, Christian; Meyer, Anne S.

    2014-01-01

    Microbial phytases (EC 3.1.3.8) catalyse dephosphorylation of phytic acid, which is the primary storage compound for phosphorous in cereal kernels. The negatively charged phosphates in phytic acid chelate iron (Fe3+) and thus retards iron bioavailability in humans 1. Supplementation of microbial...... phytase can improve iron absorption from cereal-based diets 2. In order for phytase to catalyse iron release in vivo the phytase must be robust to low pH and proteolysis in the gastric ventricle. Our work has compared the robustness of five different microbial phytases, evaluating thermal stability...

  11. Electromagnetically induced absorption via incoherent collisions

    International Nuclear Information System (INIS)

    Yang Xihua; Sheng Jiteng; Xiao Min

    2011-01-01

    We conduct theoretical studies on electromagnetically induced absorption via incoherent collisions in an inhomogeneously broadened ladder-type three-level system with the density-matrix approach. The effects of the collision-induced coherence decay rates as well as the probe laser field intensity on the probe field absorption are examined. It is shown that with the increase of the collisional decay rates in a moderate range, a narrow dip due to electromagnetically induced transparency superimposed on the Doppler-broadened absorption background can be turned into a narrow peak under the conditions that the probe field intensity is not very weak as compared to the pump field, which results from the enhancement of constructive interference and suppression of destructive interference between one-photon and multiphoton transition pathways. The physical origin of the collision-assisted electromagnetically induced absorption is analyzed with a power-series solution of the density-matrix equations.

  12. Chemical Absorption Materials

    DEFF Research Database (Denmark)

    Thomsen, Kaj

    2011-01-01

    Chemical absorption materials that potentially can be used for post combustion carbon dioxide capture are discussed. They fall into five groups, alkanolamines, alkali carbonates, ammonia, amino acid salts, and ionic liquids. The chemistry of the materials is discussed and advantages and drawbacks...

  13. Neutron resonance absorption theory

    International Nuclear Information System (INIS)

    Reuss, P.

    1991-11-01

    After some recalls on the physics of neutron resonance absorption during their slowing down, this paper presents the main features of the theoretical developments performed by the french school of reactor physics: the effective reaction rate method so called Livolant-Jeanpierre theory, the generalizations carried out by the author, and the probability table method [fr

  14. Neutron irradiation effects in quartz: optical absorption and electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Guzzi, M.; Pio, F.; Spinolo, G.; Vedda, A.

    1992-01-01

    Optical absorption measurements in the 3-9 eV energy range and electron paramagnetic resonance (EPR) have been performed at 300 K and at 80 K on Sawyer PQ quartz. Both as-received and neutron-irradiated samples (neutron fluences up to 3 x 10 18 neutrons cm -2 ) have been studied. The absorption spectra have been analysed in terms of a sum of elementary Gaussian components. The effect of the neutron irradiation is to induce the presence of absorption bands at 7.6 eV (E band), at 7.1 eV (D band) and at 6 eV (E' region). The most intense peak of all the spectra is the E band (7.6 eV); its shape is complex and the existence of a double structure can be suggested. The D band is evidenced for the first time in neutron-irradiated synthetic quartz; our measurements show that this structure is correlated with the 6.0 eV band. The 'E'' region is complex; in fact, at the highest neutron fluence the optical absorption spectrum reveals the existence of four structures, at 4.7, 5.2, 5.6 and 6.0 eV, where the 4.7 eV band has the same characteristics as the D o band, which is present in amorphous silica. The comparison between the results of EPR measurements and the analysis of the complex structure of this absorption indicates that the correlation between optical absorption bands in this region and the EPR E' -centre signals suggested previously must be re-examined. (Author)

  15. Semiconductors bonds and bands

    CERN Document Server

    Ferry, David K

    2013-01-01

    As we settle into this second decade of the twenty-first century, it is evident that the advances in micro-electronics have truly revolutionized our day-to-day lifestyle. The technology is built upon semiconductors, materials in which the band gap has been engineered for special values suitable to the particular application. This book, written specifically for a one semester course for graduate students, provides a thorough understanding of the key solid state physics of semiconductors. It describes how quantum mechanics gives semiconductors unique properties that enabled the micro-electronics revolution, and sustain the ever-growing importance of this revolution.

  16. Temperature dependence of the HNO3 UV absorption cross sections

    Science.gov (United States)

    Burkholder, James B.; Talukdar, Ranajit K.; Ravishankara, A. R.; Solomon, Susan

    1993-01-01

    The temperature dependence of the HNO3 absorption cross sections between 240 and 360 K over the wavelength range 195 to 350 nm has been measured using a diode array spectrometer. Absorption cross sections were determined using both (1) absolute pressure measurements at 298 K and (2) a dual absorption cell arrangement in which the absorption spectrum at various temperatures is measured relative to the room temperature absorption spectrum. The HNO3 absorption spectrum showed a temperature dependence which is weak at short wavelengths but stronger at longer wavelengths which are important for photolysis in the lower stratosphere. The 298 K absorption cross sections were found to be larger than the values currently recommended for atmospheric modeling (DeMore et al., 1992). Our absorption cross section data are critically compared with the previous measurements of both room temperature and temperature-dependent absorption cross sections. Temperature-dependent absorption cross sections of HNO3 are recommended for use in atmospheric modeling. These temperature dependent HNO3 absorption cross sections were used in a two-dimensional dynamical-photochemical model to demonstrate the effects of the revised absorption cross sections on loss rate of HNO3 and the abundance of NO2 in the stratosphere.

  17. Microstrip microwave band gap structures

    Indian Academy of Sciences (India)

    Microwave band gap structures exhibit certain stop band characteristics based on the periodicity, impedance contrast and effective refractive index contrast. These structures though formed in one-, two- and three-dimensional periodicity, are huge in size. In this paper, microstrip-based microwave band gap structures are ...

  18. Particulate absorption properties in the Red Sea from hyperspectral particulate absorption spectra

    KAUST Repository

    Tiwari, Surya Prakash

    2018-03-16

    This paper aims to describe the variability of particulate absorption properties using a unique hyperspectral dataset collected in the Red Sea as part of the TARA Oceans expedition. The absorption contributions by phytoplankton (aph) and non-algal particles (aNAP) to the total particulate absorption coefficients are determined using a numerical decomposition method (NDM). The NDM is validated by comparing the NDM derived values of aph and aNAP with simulated values of aph and aNAP are found to be in excellent agreement for the selected wavelengths (i.e., 443, 490, 555, and 676nm) with high correlation coefficient (R2), low root mean square error (RMSE), mean relative error (MRE), and with a slope close to unity. Further analyses showed that the total particulate absorption coefficients (i.e., ap(443)average = 0.01995m−1) were dominated by phytoplankton absorption (i.e., aph(443)average = 0.01743m−1) with a smaller contribution by non-algal particles absorption (i.e., aNAP(443)average = 0.002524m−1). The chlorophyll a is computed using the absorption based Line Height Method (LHM). The derived chlorophyll-specific absorption ((a⁎ph = aph(λ)/ChlLH)) showed more variability in the blue part of spectrum as compared to the red part of spectrum representative of the package effect and changes in pigment composition. A new parametrization proposed also enabled the reconstruction of a⁎ph(λ) for the Red Sea. Comparison of derived spectral constants with the spectral constants of existing models showed that our study A(λ) values are consistent with the existing values, despite there is a divergence with the B(λ) values. This study provides valuable information derived from the particulate absorption properties and its spectral variability and this would help us to determine the relationship between the phytoplankton absorption coefficients and chlorophyll a and its host of variables for the Red Sea.

  19. Photochemistry and electron-transfer mechanism of transition metal oxalato complexes excited in the charge transfer band.

    Science.gov (United States)

    Chen, Jie; Zhang, Hua; Tomov, Ivan V; Ding, Xunliang; Rentzepis, Peter M

    2008-10-07

    The photoredox reaction of trisoxalato cobaltate (III) has been studied by means of ultrafast extended x-ray absorption fine structure and optical transient spectroscopy after excitation in the charge-transfer band with 267-nm femtosecond pulses. The Co-O transient bond length changes and the optical spectra and kinetics have been measured and compared with those of ferrioxalate. Data presented here strongly suggest that both of these metal oxalato complexes operate under similar photoredox reaction mechanisms where the primary reaction involves the dissociation of a metal-oxygen bond. These results also indicate that excitation in the charge-transfer band is not a sufficient condition for the intramolecular electron transfer to be the dominant photochemistry reaction mechanism.

  20. Nonlinear optical response of relativistic energy bands: Application to phosphorene

    Science.gov (United States)

    Pedersen, Thomas Garm

    2017-06-01

    The energy dispersion relation of massive relativistic particles is characterized by a gradual transition from parabolic to linear momentum dependence. A similar pseudorelativistic behavior is found in the energy bands of certain two-dimensional semiconductors. Focusing on phosphorene, we investigate the response of pseudorelativistic electrons to electromagnetic fields. It is demonstrated that a near-analytical expression for the induced current containing the field to all orders can be obtained. We analyze the harmonic content of the current and study the field-, frequency-, and band-gap dependence of the nonlinear response. A detailed analysis of third-harmonic generation and saturable absorption is made.

  1. Luminescence and optical absorption determination in porous silicon

    International Nuclear Information System (INIS)

    Nogal, U.; Calderon, A.; Marin, E.; Rojas T, J. B.; Juarez, A. G.

    2012-10-01

    We applied the photoacoustic spectroscopy technique in order to obtain the optical absorption spectrum in porous silicon samples prepared by electrochemical anodic etching on n-type, phosphorous doped, (100)-oriented crystal-line silicon wafer with thickness of 300 μm and 1-5 ωcm resistivity. The porous layers were prepared with etching times of 13, 20, 30, 40 and 60 minutes. Also, we realized a comparison among the optical absorption spectrum with the photoluminescence and photo reflectance ones, both obtained at room temperature. Our results show that the absorption spectrum of the samples of porous silicon depends notably of the etching time an it consist of two distinguishable absorption bands, one in the Vis region and the other one in the UV region. (Author)

  2. Comparison of near-infrared absorption and photoresponse of silicon doped with Se and Te via fs-laser irradiation

    Science.gov (United States)

    Du, Lingyan; Wu, Zhiming; Shi, Yuanlin; Li, Siyu; Jiang, Yadong

    2017-12-01

    We compare the surface morphology, optical properties and infrared photoresponse of Se- and Te-doped silicon prepared by femtosecond-laser irradiation of Si coated with dopant thin films. Both the two samples show similar column structures and strong sub-band gap light absorption. Annealing the doped silicon leads to attenuation of the sub-band gap absorption. However, the attenuation degree of the Se-doped silicon is greater in comparison with that of Te-doped silicon. To explain the cause of the difference in the attenuation, we fit the attenuation of experimental absorption coefficient using an equation. Thermal activation energy and pre-exponential factor in the equation are considered to be associated with metastability of chalcogen-Si bonds and dopant diffusivity, respectively. We extract the thermal activation energy and pre-exponential factor of Se- and Te-doped silicon from the fitted data, and the results suggest that it is different dopant diffusivity instead of different chalcogens-Si bond energy causes difference in the attenuation. Furthermore, Te-doped silicon photodiode exhibits higher photocurrent response, which makes it possible to be more valuable candidate for fabricating Si-based photoelectric detector.

  3. Absorption spectroscopy of heavy alkaline earth metals Ba and Sr in rare gas matrices--CCSD(T) calculations and atomic site occupancies.

    Science.gov (United States)

    Davis, Barry M; McCaffrey, John G

    2016-01-28

    Isolation of the heavier alkaline earth metals Ba and Sr in the solid rare gases (RGs) Ar, Kr, and Xe is analysed with absorption spectroscopy and interpreted partly with the assistance of ab initio calculations of the diatomic M ⋅ RG ground state interaction potentials. The y(1)P ← a(1)S resonance transitions in the visible spectral region are used to compare the isolation conditions of these two metal atom systems and calcium. Complex absorption bands were recorded in all three metal atom systems even after extensive sample annealing. Coupled cluster calculations conducted on the ground states of the nine M ⋅ RG diatomics (M = Ca, Sr, and Ba; RG = Ar, Kr, and Xe) at the coupled cluster single, double, and non-iterative triple level of theory revealed long bond lengths (>5 Å) and shallow bound regions (rare gas dimers, with the consequence that isolation of these metal atoms in a single substitutional site of the solid rare gas is unlikely, with the possible exception of Ca/Xe. The luminescence of metal dimer bands has been recorded for Ba and Sr revealing very different behaviours. Resonance fluorescence with a lifetime of 15 ns is observed for the lowest energy transition of Sr2 while this transition is quenched in Ba2. This behaviour is consistent with the absence of vibrational structure on the dimer absorption band in Ba2 indicating lifetime broadening arising from efficient relaxation to low-lying molecular states. More extensive 2D excitation-emission data recorded for the complex site structures present on the absorption bands of the atomic Ba and Sr systems will be presented in future publications.

  4. Morphologies of omega band auroras

    Science.gov (United States)

    Sato, Natsuo; Yukimatu, Akira Sessai; Tanaka, Yoshimasa; Hori, Tomoaki

    2017-08-01

    We examined the morphological signatures of 315 omega band aurora events observed using the Time History of Events and Macroscale Interactions during Substorm ground-based all-sky imager network over a period of 8 years. We find that omega bands can be classified into the following three subtypes: (1) classical (O-type) omega bands, (2) torch or tongue (T-type) omega bands, and (3) combinations of classical and torch or tongue (O/T-type) omega bands. The statistical results show that T-type bands occur the most frequently (45%), followed by O/T-type bands (35%) and O-type bands (18%). We also examined the morphologies of the omega bands during their formation, from the growth period to the declining period through the maximum period. Interestingly, the omega bands are not stable, but rather exhibit dynamic changes in shape, intensity, and motion. They grow from small-scale bumps (seeds) at the poleward boundary of preexisting east-west-aligned auroras, rather than via the rotation or shear motion of preexisting east-west-aligned auroras, and do not exhibit any shear motion during the periods of auroral activity growth. Furthermore, the auroral luminosity is observed to increase during the declining period, and the total time from the start of the growth period to the end of the declining period is found to be about 20 min. Such dynamical signatures may be important in determining the mechanism responsible for omega band formation.

  5. Absorptive Capacity and Diversity

    DEFF Research Database (Denmark)

    Kristinsson, Kári

    international business, organizational economics, strategic management, technology management and last but not least neo-Schumpeterian economics. The goal of this dissertation is to examine what many consider as neglected arguments from the work by Cohen and Levinthal and thereby illuminate an otherwise......One of the most influential contributions to neo-Schumpeterian economics is Cohen and Levinthal‘s papers on absorptive capacity. Since their publication in the late 1980s and early 1990s the concept absorptive capacity has had substantial impact on research in economics and management, including...... overlooked area of research. Although research based on Cohen and Levinthal‘s work has made considerable impact, there is scarcity of research on certain fundamental points argued by Cohen and Levinthal. Among these is the importance of employee diversity as well as the type and nature of interaction between...

  6. Size-tunable band alignment and optoelectronic properties of transition metal dichalcogenide van der Waals heterostructures

    Science.gov (United States)

    Zhao, Yipeng; Yu, Wangbing; Ouyang, Gang

    2018-01-01

    2D transition metal dichalcogenide (TMDC)-based heterostructures exhibit several fascinating properties that can address the emerging market of energy conversion and storage devices. Current achievements show that the vertical stacked TMDC heterostructures can form type II band alignment and possess significant optoelectronic properties. However, a detailed analytical understanding of how to quantify the band alignment and band offset as well as the optimized power conversion efficiency (PCE) is still lacking. Herein, we propose an analytical model to exhibit the PCEs of TMDC van der Waals (vdW) heterostructures and explore the intrinsic mechanism of photovoltaic conversion based on the detailed balance principle and atomic-bond-relaxation correlation mechanism. We find that the PCE of monolayer MoS2/WSe2 can be up to 1.70%, and that of the MoS2/WSe2 vdW heterostructures increases with thickness, owing to increasing optical absorption. Moreover, the results are validated by comparing them with the available evidence, providing realistic efficiency targets and design principles. Highlights • Both electronic and optoelectronic models are developed for vertical stacked MoS2/WSe2 heterostructures. • The underlying mechanism on size effect of electronic and optoelectronic properties for vertical stacked MoS2/WSe2 heterostructures is clarified. • The macroscopically measurable quantities and the microscopical bond identities are connected.

  7. Sound absorption of snow

    OpenAIRE

    Maysenhölder, W.; Schneebeli, M.; Zhou, X.; Zhang, T.; Heggli, M.

    2008-01-01

    Recently fallen snow possesses good sound-absorbing properties. This fact is well-known and confirmed by measurements. Is the filigree structure of snowflakes decisive? In principle we know that the sound-absorbing capacity of a porous material is dependent on its structure. But until now the question as to which structural characteristics are significant has been insufficiently answered. Detailed investigations of snow are to explain this fact by precise measurements of the sound absorption,...

  8. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  9. X-ray absorption near-edge structure of GaN with high Mn concentration grown on SiC

    International Nuclear Information System (INIS)

    Sancho-Juan, O; Cantarero, A; Garro, N; Cros, A; Martinez-Criado, G; Salome, M; Susini, J; Olguin, D; Dhar, S

    2009-01-01

    By means of x-ray absorption near-edge structure (XANES) several Ga 1-x Mn x N (0.03 2 ↑ band localized in the gap region, and the corresponding anti-bonding state t 2 ↓, which seem to be responsible for the double structure which appears at the pre-edge absorption region. The shoulders and main absorption peak of the XANES spectra are attributed to transitions from the Mn(1s) band to the conduction bands, which are partially dipole allowed because of the Mn(4p) contribution to these bands.

  10. Relic Neutrino Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Eberle, b

    2004-01-28

    Resonant annihilation of extremely high-energy cosmic neutrinos on big-bang relic anti-neutrinos (and vice versa) into Z-bosons leads to sizable absorption dips in the neutrino flux to be observed at Earth. The high-energy edges of these dips are fixed, via the resonance energies, by the neutrino masses alone. Their depths are determined by the cosmic neutrino background density, by the cosmological parameters determining the expansion rate of the universe, and by the large redshift history of the cosmic neutrino sources. We investigate the possibility of determining the existence of the cosmic neutrino background within the next decade from a measurement of these absorption dips in the neutrino flux. As a by-product, we study the prospects to infer the absolute neutrino mass scale. We find that, with the presently planned neutrino detectors (ANITA, Auger, EUSO, OWL, RICE, and SalSA) operating in the relevant energy regime above 10{sup 21} eV, relic neutrino absorption spectroscopy becomes a realistic possibility. It requires, however, the existence of extremely powerful neutrino sources, which should be opaque to nucleons and high-energy photons to evade present constraints. Furthermore, the neutrino mass spectrum must be quasi-degenerate to optimize the dip, which implies m{sub {nu}} 0.1 eV for the lightest neutrino. With a second generation of neutrino detectors, these demanding requirements can be relaxed considerably.

  11. Effects of band-tails on the subthreshold characteristics of nanowire band-to-band tunneling transistors

    Science.gov (United States)

    Khayer, M. Abul; Lake, Roger K.

    2011-10-01

    High source doping is required to support the high electric fields necessary to provide sufficient drive currents in interband tunnel field effect transistors (TFETs). High doping is associated with band-tails in the density of states that decay exponentially into the bandgap with decay constants that can be comparable to the room temperature thermal energy kBT. This compromises the core operational principal of a TFET of a hard energy cut-off to the injected channel carrier distribution provided by the source valence band edge. If the band-tails are limited to the source region, they have minimal effect for short channels ≤10 nm, since the leakage current is dominated by direct, coherent tunneling through the channel. For longer 20 nm channels, source band-tails can double the inverse subthreshold slope but still leave it below the ideal 60 mV/decade value with on-off current ratios greater than 106 using a supply voltage of 0.4 V. Band-tails both in the source and channel are more detrimental for both 10 and 20 nm channels. On-off current ratios are reduced to ≥103 and ≥104 for the 10 nm and 20 nm channel devices, respectively.

  12. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  13. Wide Band Artificial Pulsar

    Science.gov (United States)

    Parsons, Zackary

    2017-01-01

    The Wide Band Artificial Pulsar (WBAP) is an instrument verification device designed and built by the National Radio Astronomy Observatory (NRAO) in Green Bank, West Virgina. The site currently operates the Green Bank Ultimate Pulsar Processing Instrument (GUPPI) and the Versatile Green Bank Astronomical Spectrometer (VEGAS) digital backends for their radio telescopes. The commissioning and continued support for these sophisticated backends has demonstrated a need for a device capable of producing an accurate artificial pulsar signal. The WBAP is designed to provide a very close approximation to an actual pulsar signal. This presentation is intended to provide an overview of the current hardware and software implementations and to also share the current results from testing using the WBAP.

  14. Role of non-Condon vibronic coupling and conformation change on two-photon absorption spectra of green fluorescent protein

    Science.gov (United States)

    Ai, Yuejie; Tian, Guangjun; Luo, Yi

    2013-07-01

    Two-photon absorption spectra of green fluorescent proteins (GFPs) often show a blue-shift band compared to their conventional one-photon absorption spectra, which is an intriguing feature that has not been well understood. We present here a systematic study on one- and two-photon spectra of GFP chromophore by means of the density functional response theory and complete active space self-consistent field (CASSCF) methods. It shows that the popular density functional fails to provide correct vibrational progression for the spectra. The non-Condon vibronic coupling, through the localised intrinsic vibrational modes of the chromophore, is responsible for the blue-shift in the TPA spectra. The cis to trans isomerisation can be identified in high-resolution TPA spectra. Our calculations demonstrate that the high level ab initio multiconfigurational CASSCF method, rather than the conventional density functional theory is required for investigating the essential excited-state properties of the GFP chromophore.

  15. Influence of TiO2 Nanocrystals Fabricating Dye-Sensitized Solar Cell on the Absorption Spectra of N719 Sensitizer

    Directory of Open Access Journals (Sweden)

    Puhong Wen

    2012-01-01

    Full Text Available The absorption spectra of N719 sensitizer anchored on the films prepared by TiO2 nanocrystals with different morphology and size were investigated for improving the performance of dye-sensitized solar cell (DSC. We find that the morphology and size of TiO2 nanocrystals can affect the UV-vis and FT-IR spectra of the sensitizer anchored on their surfaces. In particular, the low-energy metal-to-ligand charge-transfer transitions (MLCT band in the visible absorption spectra of N719 is strongly affected, and locations of these MLCT bands revealed larger differences. The results indicate that there is a red shift of MLCT band in the spectra obtained by using TiO2 nanocrystals with long morphology and large size compared to that in solution. And it produced a larger red-shift on the MLCT band after TiO2 nanocrystals with small size mixed with some long nanocrystals. Accordingly, the utilization rate to visible light is increased. This is a reason why the DSC prepared by using such film as a photoelectrode has better performance than before mixing.

  16. Comparative ligational, optical band gap and biological studies on Cr(III) and Fe(III) complexes of hydrazones derived from 2-hydrazinyl-2-oxo-N-phenylacetamide with both vanillin and O-vanillin

    Science.gov (United States)

    Yousef, T. A.; Abu El-Reash, G. M.; Attia, M. I.; El-Tabai, M. N.

    2015-09-01

    The Cr(III) and Fe(III) complexes of hydrazones derived from the condensation of 2-hydrazinyl-2-oxo-N-phenylacetamide with both vanillin and o-vanillin synthesized and characterized by different conventional physicochemical techniques. The kinetic and thermodynamic parameters for the different decomposition steps were calculated using Coats-Redfern and Horowitz-Metzger equations. The bond lengths, bond angles, HOMO, LUMO, dipole moment and binding energy calculated by DFT calculations. The optical band gap (Eg) values equal 3.28, 3.03, 3.58 and 3.57 eV for [Cr(HL1)Cl2(H2O)2](0.75H2O), [Cr(HL2)Cl2(H2O)](H2O), [Fe(HL1)Cl2(H2O)2](0.5H2O) and [Fe(HL2)2Cl(H2O)](3H2O) complexes, respectively. The antibacterial activities tested against Bacillus subtilis and Escherichia coli bacteria.

  17. Engineering intermediate-band photovoltaic material by heavily co-doping selenium and nitrogen in silicon

    Science.gov (United States)

    Dong, Xiao; Wang, Yongyong; Song, Xiaohui

    2018-01-01

    Among the various dimer configurations, the substitutional dimer exhibits the lowest formation energy and can form an impurity band that overlaps with the conduction band. The impurity band turns into an isolated and partially filled intermediate-band in the bandgap when the two impurity atoms are separated from a dimer to the remotest distance. The configurations with different impurity atom distances are stable in the Si material owing to their constant formation energy and can lead to a significant enhancement of the optical absorption in the infrared wavelength range.

  18. Method and apparatus for aerosol particle absorption spectroscopy

    Science.gov (United States)

    Campillo, Anthony J.; Lin, Horn-Bond

    1983-11-15

    A method and apparatus for determining the absorption spectra, and other properties, of aerosol particles. A heating beam source provides a beam of electromagnetic energy which is scanned through the region of the spectrum which is of interest. Particles exposed to the heating beam which have absorption bands within the band width of the heating beam absorb energy from the beam. The particles are also illuminated by light of a wave length such that the light is scattered by the particles. The absorption spectra of the particles can thus be determined from an analysis of the scattered light since the absorption of energy by the particles will affect the way the light is scattered. Preferably the heating beam is modulated to simplify the analysis of the scattered light. In one embodiment the heating beam is intensity modulated so that the scattered light will also be intensity modulated when the particles absorb energy. In another embodiment the heating beam passes through an interferometer and the scattered light reflects the Fourier Transform of the absorption spectra.

  19. Extended band anti-crossing model for dilute bismides

    Science.gov (United States)

    Hader, J.; Badescu, S. C.; Bannow, L. C.; Moloney, J. V.; Johnson, S. R.; Koch, S. W.

    2018-02-01

    Bandstructure properties of dilute bismide bulk systems are calculated using density functional theory. An extended band anti-crossing model is introduced to fit the obtained results. Using these as inputs for a fully microscopic many-body theory, absorption and photoluminescence spectra are computed for bulk and quantum-well systems. Comparison to experimental results identifies the applicability range of the new anti-crossing model.

  20. [A comparative study of cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc in brown rice and fish by inductively coupled plasma-mass spectrometry (ICP-MS) and atomic absorption spectrometry].

    Science.gov (United States)

    Oshima, Harumi; Ueno, Eiji; Saito, Isao; Matsumoto, Hiroshi

    2004-10-01

    A study was conducted to evaluate the applicability of ICP-MS techniques for determination of metals in brown rice and fish. Cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc were determined by this method. An open digestion with nitric acid (Method A) and a rapid open digestion with nitric acid and hydrochloric acid (Method B) were used to solubilize analytes in samples, and these procedures were followed by ICP-MS analysis. Recovery of certified elements from standard reference materials by Method A and Method B ranged from 92 to 110% except for mercury (70 to 100%). Analytical results of brown rice and fish samples obtained by this ICP-MS agreed with those obtained by atomic absorption spectrometry (AAS). The results of this study demonstrate that quadrupole ICP-MS provides precise and accurate measurements of the elements tested in brown rice and fish samples.

  1. Excited negative parity bands in 160Yb

    Science.gov (United States)

    Saha, A.; Bhattacharjee, T.; Curien, D.; Dedes, I.; Mazurek, K.; Banerjee, S. R.; Rajbanshi, S.; Bisoi, A.; de Angelis, G.; Bhattacharya, Soumik; Bhattacharyya, S.; Biswas, S.; Chakraborty, A.; Das Gupta, S.; Dey, B.; Goswami, A.; Mondal, D.; Pandit, D.; Palit, R.; Roy, T.; Singh, R. P.; Saha Sarkar, M.; Saha, S.; Sethi, J.

    2018-03-01

    Negative parity rotational bands in {} 70160Yb{}90 nucleus have been studied. They were populated in the 148Sm(16O, 4n)160Yb reaction at 90 MeV. The gamma-coincidence data have been collected using Indian National Gamma Array composed of twenty Compton suppressed clover germanium (Ge) detectors. Double gating on triple gamma coincidence data were selectively used to develop the decay scheme for these negative parity bands by identifying and taking care of the multiplet transitions. The even- and odd-spin negative parity bands in 160Yb have been studied by comparing the reduced transition probability ratios with the similar bands in neighbouring even-even rare earth nuclei. It is concluded that the concerned odd-spin and even-spin bands are not signature partners and that their structures are compatible with those of the ‘pear-shape’ and ‘pyramid-shape’ oscillations, respectively, the octupole shapes superposed with the quadrupole shape of the ground-state.

  2. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  3. Optical absorption of sodium copper chlorophyllin thin films in UV-vis-NIR region.

    Science.gov (United States)

    Farag, A A M

    2006-11-01

    The optical absorption studies of sodium copper chlorophyllin thin films (SCC), prepared by spray pyrolysis, in the UV-vis-NIR region was reported for the first time. Several new discrete transitions are observed in the UV-vis region of the spectra in addition to a strong continuum component in the IR region. The spectra of the infrared absorption allow characterization of vibration modes for the powder and thin films of SCC. The absorption spectrum recorded in the UV-vis region showed different absorption bands, namely the Soret (B) in the region 340-450 nm and Q-band in the region 600-700 nm and other band labeled N in the 240-320 region. Some important spectral parameters namely optical absorption coefficient (alpha), molar extinction coefficient (epsilon(molar)), oscillator strength (f), electric dipole strength (q(2)) and absorption half bandwidth (Deltalambda) of the principle optical transitions were evaluated. The analysis of the absorption coefficient in the absorption region revealed direct transitions and the energy gap was estimated as 1.63 eV. Discussion of the obtained results and their comparison with the previous published data are also given.

  4. Emission and absorption cross section of thulium doped silica fibers

    DEFF Research Database (Denmark)

    Agger, Søren Dyøe; Povlsen, Jørn Hedegaard

    2006-01-01

    A thorough investigation of the emission and absorption spectra of the (F-3(4),H-3(6)) band in thulium doped silica fibers has been performed. All the basic parameters of thulium in silica have been extracted with the purpose of further analysis in laser and amplifier simulations. The experimental...... methods used to obtain the scaled cross sections have been carefully selected in order to avoid problems associated with calibrated measurements and knowledge of the radiative lifetime. The values of the absorption cross sections agree well with previously reported values, however the peak emission...

  5. Optical absorption spectroscopy of natural and irradiated pink tourmaline

    International Nuclear Information System (INIS)

    Camargo, M.B.; Isotani, S.

    1985-01-01

    The Brazilian natural pink tourmaline is studied through the polarized optical absorption measurements. The effect of increasing doses of γ-rays from 60 Co in the spectra were determined (maximum of 20MGy). The following optical absorption bands were observed: 8,500 and 14,800 cm -1 assigned to d-d transitions of Fe 2+ in b- and c-sites, respectively; 19,500 and 25,500 cm -1 assigned to 5 E → 5 A 1 and 5 B 2 → 5 A 1 d-d transitions of Mn 3+ , respectively. (Author) [pt

  6. Characterization of the Valence and Conduction Band Levels of n = 1 2D Perovskites: A Combined Experimental and Theoretical Investigation

    KAUST Repository

    Silver, Scott

    2018-02-13

    This study presents a combined experimental and theoretical study of the electronic structure of two 2D metal halide perovskite films. Ultraviolet and inverse photoemission spectroscopies are performed on solution-processed thin films of the n = 1 layered perovskite butylammonium lead iodide and bromide, BA2PbI4 and BA2PbBr4, characterized by optical absorption and X-ray diffraction, to determine their valence and conduction band densities of states, transport gaps, and exciton binding energies. The electron spectroscopy results are compared with the densities of states determined by density functional theory calculations. The remarkable agreement between experiment and calculation enables a detailed identification and analysis of the organic and inorganic contributions to the valence and conduction bands of these two hybrid perovskites. The electron affinity and ionization energies are found to be 3.1 and 5.8 eV for BA2PbI4, and 3.1 and 6.5 eV for BA2PbBr4. The exciton binding energies are estimated to be 260 and 300 meV for the two materials, respectively. The 2D lead iodide and bromide perovskites exhibit significantly less band dispersion and a larger density of states at the band edges than the 3D analogs. The effects of using various organic ligands are also discussed.

  7. Pixel-based absorption correction for dual-tracer fluorescence imaging of receptor binding potential.

    Science.gov (United States)

    Kanick, Stephen C; Tichauer, Kenneth M; Gunn, Jason; Samkoe, Kimberley S; Pogue, Brian W

    2014-10-01

    Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order to correct for these tissue optical differences in signal detection. Changes in blood volume [1-3%] and hemoglobin oxygen saturation [0-100%] were demonstrated to introduce substantial distortions to receptor binding estimates (error > 30%), whereas sampled depth was relatively insensitive to wavelength (error pixel-by-pixel normalization of tracer inputs immediately post-injection was found to account for spatial heterogeneities in local absorption properties. Application of the pixel-based normalization method to an in vivo imaging study demonstrated significant improvement, as compared with a reference tissue normalization approach.

  8. Pixel-based absorption correction for dual-tracer fluorescence imaging of receptor binding potential

    Science.gov (United States)

    Kanick, Stephen C.; Tichauer, Kenneth M.; Gunn, Jason; Samkoe, Kimberley S.; Pogue, Brian W.

    2014-01-01

    Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order to correct for these tissue optical differences in signal detection. Changes in blood volume [1-3%] and hemoglobin oxygen saturation [0-100%] were demonstrated to introduce substantial distortions to receptor binding estimates (error > 30%), whereas sampled depth was relatively insensitive to wavelength (error tracer inputs immediately post-injection was found to account for spatial heterogeneities in local absorption properties. Application of the pixel-based normalization method to an in vivo imaging study demonstrated significant improvement, as compared with a reference tissue normalization approach. PMID:25360349

  9. A CCD-based system for the detection of DNA in electrophoresis gels by UV absorption

    International Nuclear Information System (INIS)

    Mahon, A.R.; MacDonald, J.H.; Mainwood, A.; Ott, R.J.

    1999-01-01

    A method and apparatus for the detection and quantification of large fragments of unlabelled nucleic acids in agarose gels is presented. The technique is based on ultraviolet (UV) absorption by nucleotides. A deuterium source illuminates individual sample lanes of an electrophoresis gel via an array of optical fibres. As DNA bands pass through the illuminated region of the gel the amount of UV light transmitted is reduced because of absorption by the DNA. During electrophoresis the regions of DNA are detected on-line using a UV-sensitive charge coupled device (CCD). As the absorption coefficient is proportional to the mass of DNA the technique is inherently quantitative. The mass of DNA in a region of the gel is approximately proportional to the integrated signal in the corresponding section of the CCD image. This system currently has a detection limit of less than 1.25 ng compared with 2-10 ng for the most popular conventional technique, ethidium bromide (EtBr) staining. In addition the DNA sample remains in its native state. The removal of the carcinogenic dye from the detection procedure greatly reduces associated biological hazards. (author)

  10. Iodine Absorption Cells Purity Testing

    Directory of Open Access Journals (Sweden)

    Jan Hrabina

    2017-01-01

    Full Text Available This article deals with the evaluation of the chemical purity of iodine-filled absorption cells and the optical frequency references used for the frequency locking of laser standards. We summarize the recent trends and progress in absorption cell technology and we focus on methods for iodine cell purity testing. We compare two independent experimental systems based on the laser-induced fluorescence method, showing an improvement of measurement uncertainty by introducing a compensation system reducing unwanted influences. We show the advantages of this technique, which is relatively simple and does not require extensive hardware equipment. As an alternative to the traditionally used methods we propose an approach of hyperfine transitions’ spectral linewidth measurement. The key characteristic of this method is demonstrated on a set of testing iodine cells. The relationship between laser-induced fluorescence and transition linewidth methods will be presented as well as a summary of the advantages and disadvantages of the proposed technique (in comparison with traditional measurement approaches.

  11. Neutron irradiation effects in amorphous SiO2: optical absorption and electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Guzzi, M.; Martini, M.; Paleari, A.; Pio, F.; Vedda, A.; Azzoni, C.B.

    1993-01-01

    Optical absorption spectra of as-grown and neutron-irradiated amorphous SiO 2 , both fused natural quartz and synthetic silica, have been analysed in the ultraviolet region below the fundamental edge. The description of the optical spectrum has been further clarified by a detailed study of the spectral components as a function of the neutron irradiation in different types of silica; we have verified known correlations between optical bands and between bands and paramagnetic centres. In 'as-grown' fused quartz samples, a previously unreported band at 6.2 eV has been detected. 'As-grown' synthetic silicas do not show any band, up to the intrinsic absorption edge. In the irradiated samples, the experimental results suggest a correlation between two bands at 5.8 and 7.1 eV, while previous attribution of the bands at 5.0 eV (B 2 band) and 7.6 eV (E band) to the same defect is discussed. The role of impurities in the optical absorption and in the radiation hardness is also considered. (author)

  12. Absorption heat pumps

    Science.gov (United States)

    Huhtinen, M.; Heikkilae, M.; Andersson, R.

    1987-03-01

    The aim of the study was to analyze the technical and economic feasibility of absorption heat pumps in Finland. The work was done as a case study: the technical and economic analyses have been carried out for six different cases, where in each the suitable size and type of the heat pump plant and the auxiliary components and connections were specified. The study also detailed the costs concerning the procurement, installation and test runs of the machinery, as well as the savings in energy costs incurred by the introduction of the plant. Conclusions were drawn of the economic viability of the applications studied. The following cases were analyzed: heat recovery from flue gases and productin of district heat in plants using peat, natural gas, and municipal wastes as a fuel. Heat recovery in the pulp and paper industry for the upgrading of pressure of secondary steam and for the heating of white liquor and combustion and drying the air. Heat recovery in a peat-fulled heat and power plant from flue gases that have been used for the drying of peat. According to the study, the absorption heat pump suits best to the production of district heat, when the heat source is the primary energy is steam produced by the boiler. Included in the flue as condensing is the purification of flue gases. Accordingly, benefit is gained on two levels in thick applications. In heat and power plants the use of absorption heat pumps is less economical, due to the fact that the steam used by the pump reduces the production of electricity, which is rated clearly higher than heat.

  13. Incorporating Methyl and Phenyl Substituted Stannylene Units into Oligosilanes. The Influence on Optical Absorption Properties.

    Science.gov (United States)

    Stella, Filippo; Marschner, Christoph; Baumgartner, Judith

    2017-12-12

    Molecules containing catenated heavy group 14 atoms are known to exhibit the interesting property of σ-bond electron delocalization. While this is well studied for oligo- and polysilanes the current paper addresses the UV-absorption properties of small tin containing oligosilanes in order to evaluate the effects of Sn-Si and Sn-Sn bonds as well as the results of substituent exchange from methyl to phenyl groups. The new stannasilanes were compared to previously investigated oligosilanes of equal chain lengths and substituent pattern. Replacing the central SiMe₂ group in a pentasilane by a SnMe₂ unit caused a bathochromic shift of the low-energy band (λ max = 260 nm) of 14 nm in the UV spectrum. If, instead of a SnMe 2, a SnPh₂ unit is incorporated, the bathochromic shift of 33 nm is substantially larger. Keeping the SnMe₂ unit and replacing the two central silicon with tin atoms causes shift of the respective band (λ = 286 nm) some 26 nm to the red. A similar approach for hexasilanes where the model oligosilane [(Me₃Si)₃Si]₂(SiMe₂)₂ (λ max = 253 nm) was modified in a way that the central tetramethyldisilanylene unit was exchanged for a tetraphenyldistannanylene caused a 50 nm bathochromic shift to a low-energy band with λ max = 303 nm.

  14. Rapidly variable relatvistic absorption

    Science.gov (United States)

    Parker, M.; Pinto, C.; Fabian, A.; Lohfink, A.; Buisson, D.; Alston, W.; Jiang, J.

    2017-10-01

    I will present results from the 1.5Ms XMM-Newton observing campaign on the most X-ray variable AGN, IRAS 13224-3809. We find a series of nine absorption lines with a velocity of 0.24c from an ultra-fast outflow. For the first time, we are able to see extremely rapid variability of the UFO features, and can link this to the X-ray variability from the inner accretion disk. We find a clear flux dependence of the outflow features, suggesting that the wind is ionized by increasing X-ray emission.

  15. Electronic absorption spectra of rare earth (III) species in NaCl-2CsCl eutectic based melts

    Science.gov (United States)

    Volkovich, V. A.; Ivanov, A. B.; Yakimov, S. M.; Tsarevskii, D. V.; Golovanova, O. A.; Sukhikh, V. V.; Griffiths, T. R.

    2016-09-01

    Electronic absorption spectra of ions of trivalent rare earth elements were measured in the melts based on NaCl-2CsCl eutectic in the wavelength ranges of 190-1350 and 1450-1700 nm. The measurements were performed at 550-850 °C. The EAS of Y, La, Ce and Lu containing melts have no absorption bands in the studied regions. For the remaining REEs (Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb) the absorption bands in the EAS were assigned to the corresponding f-f electron transitions. The Stark effect was observed for Yb(III) F5/2 excited state. Increasing temperature leads to decreasing intensity of the absorption bands, except for the bands resulting from hypersensitive transitions. Beer's law was confirmed up to 0.4 M solutions of REE.

  16. Band gap tuning of amorphous Al oxides by Zr alloying

    Energy Technology Data Exchange (ETDEWEB)

    Canulescu, S., E-mail: stec@fotonik.dtu.dk; Schou, J. [Department of Photonics Engineering, Technical University of Denmark, 4000 Roskilde (Denmark); Jones, N. C.; Hoffmann, S. V. [ISA, Department of Physics and Astronomy, Aarhus University, 8000 Aarhus (Denmark); Borca, C. N.; Piamonteze, C. [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Rechendorff, K.; Nielsen, L. P.; Almtoft, K. P. [Danish Technological Institute, Kongsvang Alle 29, 8000 Aarhus (Denmark); Gudla, V. C.; Bordo, K.; Ambat, R. [Department of Mechanical Engineering, Technical University of Denmark, 2800 Kgs-Lyngby (Denmark)

    2016-08-29

    The optical band gap and electronic structure of amorphous Al-Zr mixed oxides with Zr content ranging from 4.8 to 21.9% were determined using vacuum ultraviolet and X-ray absorption spectroscopy. The light scattering by the nano-porous structure of alumina at low wavelengths was estimated based on the Mie scattering theory. The dependence of the optical band gap of the Al-Zr mixed oxides on the Zr content deviates from linearity and decreases from 7.3 eV for pure anodized Al{sub 2}O{sub 3} to 6.45 eV for Al-Zr mixed oxides with a Zr content of 21.9%. With increasing Zr content, the conduction band minimum changes non-linearly as well. Fitting of the energy band gap values resulted in a bowing parameter of ∼2 eV. The band gap bowing of the mixed oxides is assigned to the presence of the Zr d-electron states localized below the conduction band minimum of anodized Al{sub 2}O{sub 3}.

  17. Geospatial Absorption and Regional Effects

    Directory of Open Access Journals (Sweden)

    IOAN MAC

    2009-01-01

    Full Text Available The geospatial absorptions are characterized by a specific complexity both in content and in their phenomenological and spatial manifestation fields. Such processes are differentiated according to their specificity to pre-absorption, absorption or post-absorption. The mechanisms that contribute to absorption are extremely numerous: aggregation, extension, diffusion, substitution, resistivity (resilience, stratification, borrowings, etc. Between these mechanisms frequent relations are established determining an amplification of the process and of its regional effects. The installation of the geographic osmosis phenomenon in a given territory (a place for example leads to a homogenization of the geospatial state and to the installation of the regional homogeneity.

  18. Wideband absorption in one dimensional photonic crystal with graphene-based hyperbolic metamaterials

    Science.gov (United States)

    Kang, Yongqiang; Liu, Hongmei

    2018-02-01

    A broadband absorber which was proposed by one dimensional photonic crystal (1DPC) containing graphene-based hyperbolic metamaterials (GHMM) is theoretically investigated. For TM mode, it was demonstrated to absorb roughly 90% of all available electromagnetic waves at a 14 THz absorption bandwidth at normal incidence. The absorption bandwidth was affected by Fermi energy and thickness of dielectric layer. When the incident angle was increased, the absorption value decreased, and the absorption band had a gradual blue shift. These findings have potential applications for designing broadband optoelectronic devices at mid-infrared and THz frequency range.

  19. The Zugspitze radiative closure experiment for quantifying water vapor absorption over the terrestrial and solar infrared – Part 3: Quantification of the mid- and near-infrared water vapor continuum in the 2500 to 7800 cm−1 spectral range under atmospheric conditions

    Directory of Open Access Journals (Sweden)

    A. Reichert

    2016-09-01

    Full Text Available We present a first quantification of the near-infrared (NIR water vapor continuum absorption from an atmospheric radiative closure experiment carried out at the Zugspitze (47.42° N, 10.98° E; 2964 m a.s.l.. Continuum quantification is achieved via radiative closure using radiometrically calibrated solar Fourier transform infrared (FTIR absorption spectra covering the 2500 to 7800 cm−1 spectral range. The dry atmospheric conditions at the Zugspitze site (IWV 1.4 to 3.3 mm enable continuum quantification even within water vapor absorption bands, while upper limits for continuum absorption can be provided in the centers of window regions. Throughout 75 % of the 2500 to 7800 cm−1 spectral range, the Zugspitze results agree within our estimated uncertainty with the widely used MT_CKD 2.5.2 model (Mlawer et al., 2012. In the wings of water vapor absorption bands, our measurements indicate about 2–5 times stronger continuum absorption than MT_CKD, namely in the 2800 to 3000 cm−1 and 4100 to 4200 cm−1 spectral ranges. The measurements are consistent with the laboratory measurements of Mondelain et al. (2015, which rely on cavity ring-down spectroscopy (CDRS, and the calorimetric–interferometric measurements of Bicknell et al. (2006. Compared to the recent FTIR laboratory studies of Ptashnik et al. (2012, 2013, our measurements are consistent within the estimated errors throughout most of the spectral range. However, in the wings of water vapor absorption bands our measurements indicate typically 2–3 times weaker continuum absorption under atmospheric conditions, namely in the 3200 to 3400, 4050 to 4200, and 6950 to 7050 cm−1 spectral regions.

  20. A cylindrical furnace for absorption spectral studies

    Indian Academy of Sciences (India)

    Unknown

    heating zones. The heating zone at either end provides a higher temperature compared to the one at the centre. As a result, it has the following advantage. Depositing of the material being heated on the window of the absorption cell can be avoided and thus the transmitted light from the continuum light source after passing ...

  1. Population of superdeformed bands, the competition with fission, and the barrier between normal and superdeformed states

    International Nuclear Information System (INIS)

    Khoo, T.L.; Janssens, R.V.F.; Moore, E.F.; Ahmad, I.; Carpenter, M.P.; Chasman, R.R.; Wolfs, F.L.H.; Beard, K.B.; Garg, U.; Ye, D.; Benet, P.; Daly, P.J.; Grabowski, Z.W.; Drigert, M.W.

    1990-01-01

    In this paper we report on the entry points leading to superdeformed (SD) as well as normal bands. We find that, compared to normal bands, the entry spins for the SD bands are about 9 ℎ higher, and the entry excitation energy 1--3 MeV colder. We also conclude that population of the SD bands represents successful competition against fission. SD bands in both the Dy and Hg regions are considered

  2. Transient absorption and luminescence spectra of K9 glass at sub-damage site by ultraviolet laser irradiation

    Science.gov (United States)

    Zhang, Z.; Huang, J.; Geng, F.; Zhou, X. Y.; Feng, S. Q.; Cheng, X. L.; Jiang, X. D.; Wu, W. D.; Zheng, W. G.; Tang, Y. J.

    2014-01-01

    Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. The dependence of transient absorption on laser energy and number of pulses was investigated. As the energy density increases to 2.54 and 3.18 J/cm2, the transient absorption intensity reaches to about 0.20 range from 400 to 480 nm. With the increase of number of pulses the process of residual absorption appears, which can be used to explain the fatigue effect of K9 glass. The defects in K9 glass were investigated by fluorescence and Raman spectra. The fluorescence band centered at about 410 nm is attributed to oxygen deficiency centers. The mechanism of two-photon ionization plays a critical role at sub-damage site. Compared to the Raman spectra of pristine site, intensity of Raman spectra is very high at a lower energy density, while it decreased at a higher energy density.

  3. Compression-absorption (resorption) refrigerating machinery. Modeling of reactors; Machine frigorifique a compression-absorption (resorption). Modelisation des reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O.; Feidt, M.; Benelmir, R. [LEMTA-UHP Nancy-1, 54 - Vandoeuvre-les-Nancy (France)

    1997-12-31

    This paper is a series of transparencies presenting a comparative study of the thermal performances of different types of refrigerating machineries: di-thermal with vapor compression, tri-thermal with moto-compressor, with ejector, with free piston, adsorption-type, resorption-type, absorption-type, compression-absorption-type. A prototype of ammonia-water compression-absorption heat pump is presented and modeled. (J.S.)

  4. Review of wide band-gap semiconductors technology

    Directory of Open Access Journals (Sweden)

    Jin Haiwei

    2016-01-01

    Full Text Available Silicon carbide (SiC and gallium nitride (GaN are typical representative of the wide band-gap semiconductor material, which is also known as third-generation semiconductor materials. Compared with the conventional semiconductor silicon (Si or gallium arsenide (GaAs, wide band-gap semiconductor has the wide band gap, high saturated drift velocity, high critical breakdown field and other advantages; it is a highly desirable semiconductor material applied under the case of high-power, high-temperature, high-frequency, anti-radiation environment. These advantages of wide band-gap devices make them a hot spot of semiconductor technology research in various countries. This article describes the research agenda of United States and European in this area, focusing on the recent developments of the wide band-gap technology in the US and Europe, summed up the facing challenge of the wide band-gap technology.

  5. Metallic photonic band-gap materials

    International Nuclear Information System (INIS)

    Sigalas, M.M.; Chan, C.T.; Ho, K.M.; Soukoulis, C.M.

    1995-01-01

    We calculate the transmission and absorption of electromagnetic waves propagating in two-dimensional (2D) and 3D periodic metallic photonic band-gap (PBG) structures. For 2D systems, there is substantial difference between the s- and p-polarized waves. The p-polarized waves exhibit behavior similar to the dielectric PBG's. But, the s-polarized waves have a cutoff frequency below which there are no propagating modes. For 3D systems, the results are qualitatively the same for both polarizations but there are important differences related to the topology of the structure. For 3D structures with isolated metallic scatterers (cermet topology), the behavior is similar to that of the dielectric PBG's, while for 3D structures with the metal forming a continuous network (network topology), there is a cutoff frequency below which there are no propagating modes. The systems with the network topology may have some interesting applications for frequencies less than about 1 THz where the absorption can be neglected. We also study the role of the defects in the metallic structures

  6. Diffuse Interstellar Bands: Successes and Challenges

    Science.gov (United States)

    Sonnentrucker, Paule G.; York, Donald G.; Welty, Daniel E.; Hobbs, Lew M.; Fan, Haoyu; DIB Collaboration

    2018-01-01

    To-date, the spectroscopic signatures of over 170 molecular species have been positively identified in interstellar clouds. However, the number of unidentified features observed either in emission (UIB, ERE, AME) or in absorption (Diffuse Interstellar Bands, DIBs) points to the existence of a substantial reservoir of species in interstellar space that are unaccounted for in theories of interstellar clouds and of star and planet formation. The DIBs are a set of about 600 weak absorption features detected mostly in the optical/NIR (4400 to 12000 Å) that appear to be ubiquitous in the diffuse interstellar medium (ISM). The carriers of the DIBs are potentially the champion contributors, by number, to this pool of unidentified species. While the nature of the DIB carriers remains elusive to this day, our understanding of the DIB behavior has matured to a point at which some DIBs can be used as ISM diagnostics regardless of their true nature. I will briefly review progress made in understanding the DIB dependence on the local ISM physical conditions. I will also present recent results - and the challenges that emerged- from an optical survey tailored to characterize a subset of the DIB spectrum: the broadest (FWHM >6 Å) DIB features.

  7. Changing optical band structure with single photons

    Science.gov (United States)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  8. Optical absorption of dilute nitride alloys using self-consistent Green’s function method

    OpenAIRE

    Seifikar, Masoud; O’Reilly, Eoin P; Fahy, Stephen

    2014-01-01

    We have calculated the optical absorption for InGaNAs and GaNSb using the band anticrossing (BAC) model and a self-consistent Green’s function (SCGF) method. In the BAC model, we include the interaction of isolated and pair N levels with the host matrix conduction and valence bands. In the SCGF approach, we include a full distribution of N states, with non-parabolic conduction and light-hole bands, and parabolic heavy-hole and spin-split-off bands. The comparison with experiments shows that t...

  9. Enhanced indirect optical absorption in AlAs and GaP.

    Science.gov (United States)

    Dumke, W. P.; Lorentz, M. R.; Pettit, G. D.

    1972-01-01

    Measurement and analysis of indirect interband optical absorption in GaP. Deviations from a simple indirect absorption law are shown to be consistent with those given by a model which takes into account both the variation of the energy denominators with photon energy and indirect absorption to higher-energy conduction-band valleys. The analysis of the GaP data indicates that such an analysis on data of limited absorption-constant range can provide reasonably accurate values of the direct band gap. The value of the direct band gap best fitting this model for AlAs at 6 K is 3.13 eV. In GaP and AlAs there is evidence of a higher set of extrema giving rise to an additional indirect absorption component 0.34 and 0.20 eV, respectively, above that due to the lowest-energy conduction-band minima. The strength of the absorption due to these higher-energy valleys indicates that they contain states of X sub 3 symmetry.

  10. Intestinal absorption of specific structured triacylglycerols

    DEFF Research Database (Denmark)

    Mu, Huiling; Høy, Carl-Erik

    2001-01-01

    -sn-glycerol (10:0/18:2/10:0), and 1,3-didodecanoyl-2-linoleoyl-sn-glycerol (12:0/18:2/12:0) in a rat model. Safflower oil was used in the absorption study in order to compare the absorption of medium- chain fatty acids and long-chain fatty acids, The triacylglycerol species of lymph Lipids were separated......-type triacylglycerols. From the present study we conclude that the medium-chain fatty acids from STAG, in addition to absorption into the portal blood as free fatty acids, are absorbed by the same pathway as the conventional long-chain triacylglycerols, that is, they are hydrolyzed into free fatty acids, absorbed...

  11. Determination of optical band gap of powder-form nanomaterials with improved accuracy

    Science.gov (United States)

    Ahsan, Ragib; Khan, Md. Ziaur Rahman; Basith, Mohammed Abdul

    2017-10-01

    Accurate determination of a material's optical band gap lies in the precise measurement of its absorption coefficients, either from its absorbance via the Beer-Lambert law or diffuse reflectance spectrum via the Kubelka-Munk function. Absorption coefficients of powder-form nanomaterials calculated from absorbance spectrum do not match those calculated from diffuse reflectance spectrum, implying the inaccuracy of the traditional optical band gap measurement method for such samples. We have modified the Beer-Lambert law and the Kubelka-Munk function with proper approximations for powder-form nanomaterials. Applying the modified method for powder-form nanomaterial samples, both absorbance and diffuse reflectance spectra yield exactly the same absorption coefficients and therefore accurately determine the optical band gap.

  12. Nature of the fundamental band gap in GaNxP1-x alloys

    International Nuclear Information System (INIS)

    Shan, W.; Walukiewicz, W.; Yu, K. M.; Wu, J.; Ager, J. W. III; Haller, E. E.; Xin, H. P.; Tu, C. W.

    2000-01-01

    The optical properties of GaN x P 1-x alloys (0.007≤x≤0.031) grown by gas-source molecular-beam epitaxy have been studied. An absorption edge appears in GaN x P 1-x at energy below the indirect Γ V -X C transition in GaP, and the absorption edge shifts to lower energy with increasing N concentration. Strong photomodulation signals associated with the absorption edges in GaN x P 1-x indicate that a direct fundamental optical transition is taking place, revealing that the fundamental band gap has changed from indirect to direct. This N-induced transformation from indirect to direct band gap is explained in terms of an interaction between the highly localized nitrogen states and the extended states at the Γ conduction-band minimum. (c) 2000 American Institute of Physics

  13. Photoluminescence and optical absorption in neutron-irradiated crystalline quartz

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, A.; Crivelli, B.; Martini, M.; Spinolo, G.; Vedda, A. [Istituto Nazionale Di Fisica Della Materia, Dipartimento di Fisica, Universita di Milano, Via Celoria 16, I-20133 Milano (Italy)

    1996-04-01

    Optical absorption measurements in the 3.5{endash}6.5 eV spectral range and photoluminescence spectra, excited in the 4{endash}8 eV range have been performed on neutron irradiated synthetic crystalline quartz as a function of temperature and of neutron fluence. The Gaussian deconvolution of the radiation-induced absorption spectrum in the 4.5{endash}6 eV region reveals a complex structure: five distinct components, peaking at 4.85, 5.06, 5.35, 5.62, and 5.96 eV are detected. The complexity of the absorption pattern finds a correspondence in photoluminescence spectra excited in the 5 eV region: a detailed analysis of the emission spectra as a function of excitation energy indicates the presence of three emission bands centered at 3.91, 4.23, and 4.46 eV, excited at 5.25, 4.83, and 5.03 eV respectively. Excitation in the 5.62 and 5.96 eV absorption peaks does not produce emission. The features of the 4.23 eV and of the 4.46 eV bands are very similar to those of the {alpha}{sub intrinsic} emission, already well studied in amorphous SiO{sub 2}: this suggests a possible correlation between these bands and the {alpha}{sub intrinsic} center. The 3.91 eV band does not find a correspondence in amorphous SiO{sub 2}, and so the responsible defect appears specifically related to the crystalline structure. The emission spectra excited in the E absorption band ({approx_equal}7.6 eV) present a weak band centered at 4.83 eV: its dependence on neutron irradiation dose suggests the attribution to an intrinsic center different from those responsible for the emission in the 3.8 {endash} 4.5 eV region. {copyright} {ital 1996 The American Physical Society.}

  14. Photoluminescence and optical absorption in neutron-irradiated crystalline quartz

    International Nuclear Information System (INIS)

    Corazza, A.; Crivelli, B.; Martini, M.; Spinolo, G.; Vedda, A.

    1996-01-01

    Optical absorption measurements in the 3.5 endash 6.5 eV spectral range and photoluminescence spectra, excited in the 4 endash 8 eV range have been performed on neutron irradiated synthetic crystalline quartz as a function of temperature and of neutron fluence. The Gaussian deconvolution of the radiation-induced absorption spectrum in the 4.5 endash 6 eV region reveals a complex structure: five distinct components, peaking at 4.85, 5.06, 5.35, 5.62, and 5.96 eV are detected. The complexity of the absorption pattern finds a correspondence in photoluminescence spectra excited in the 5 eV region: a detailed analysis of the emission spectra as a function of excitation energy indicates the presence of three emission bands centered at 3.91, 4.23, and 4.46 eV, excited at 5.25, 4.83, and 5.03 eV respectively. Excitation in the 5.62 and 5.96 eV absorption peaks does not produce emission. The features of the 4.23 eV and of the 4.46 eV bands are very similar to those of the α intrinsic emission, already well studied in amorphous SiO 2 : this suggests a possible correlation between these bands and the α intrinsic center. The 3.91 eV band does not find a correspondence in amorphous SiO 2 , and so the responsible defect appears specifically related to the crystalline structure. The emission spectra excited in the E absorption band (≅7.6 eV) present a weak band centered at 4.83 eV: its dependence on neutron irradiation dose suggests the attribution to an intrinsic center different from those responsible for the emission in the 3.8 endash 4.5 eV region. copyright 1996 The American Physical Society

  15. Phytosterol glycosides reduce cholesterol absorption in humans.

    Science.gov (United States)

    Lin, Xiaobo; Ma, Lina; Racette, Susan B; Anderson Spearie, Catherine L; Ostlund, Richard E

    2009-04-01

    Dietary phytosterols inhibit intestinal cholesterol absorption and regulate whole body cholesterol excretion and balance. However, they are biochemically heterogeneous and a portion is glycosylated in some foods with unknown effects on biological activity. We tested the hypothesis that phytosterol glycosides reduce cholesterol absorption in humans. Phytosterol glycosides were extracted and purified from soy lecithin in a novel two-step process. Cholesterol absorption was measured in a series of three single-meal tests given at intervals of 2 wk to each of 11 healthy subjects. In a randomized crossover design, participants received approximately 300 mg of added phytosterols in the form of phytosterol glycosides or phytosterol esters, or placebo in a test breakfast also containing 30 mg cholesterol-d7. Cholesterol absorption was estimated by mass spectrometry of plasma cholesterol-d7 enrichment 4-5 days after each test. Compared with the placebo test, phytosterol glycosides reduced cholesterol absorption by 37.6+/-4.8% (Pphytosterol esters 30.6+/-3.9% (P=0.0001). These results suggest that natural phytosterol glycosides purified from lecithin are bioactive in humans and should be included in methods of phytosterol analysis and tables of food phytosterol content.

  16. Zinc absorption in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Kertesz, A.; Bondy, D.C.

    1986-01-01

    Zinc absorption was measured in 29 patients with inflammatory bowel disease and a wide spectrum of disease activity to determine its relationship to disease activity, general nutritional state, and zinc status. Patients with severe disease requiring either supplementary oral or parenteral nutrition were excluded. The mean 65ZnCl2 absorption, in the patients, determined using a 65Zn and 51Cr stool-counting test, 45 +/- 17% (SD), was significantly lower than the values, 54 +/- 16%, in 30 healthy controls, P less than 0.05. Low 65ZnCl2 absorption was related to undernutrition, but not to disease activity in the absence of undernutrition or to zinc status estimated by leukocyte zinc measurements. Mean plasma zinc or leukocyte zinc concentrations in patients did not differ significantly from controls, and only two patients with moderate disease had leukocyte zinc values below the 5th percentile of normal. In another group of nine patients with inflammatory bowel disease of mild-to-moderate severity and minimal nutritional impairment, 65Zn absorption from an extrinsically labeled turkey test meal was 31 +/- 10% compared to 33 +/- 7% in 17 healthy controls, P greater than 0.1. Thus, impairment in 65ZnCl2 absorption in the patients selected for this study was only evident in undernourished persons with moderate or severe disease activity, but biochemical evidence of zinc deficiency was uncommon, and clinical features of zinc depletion were not encountered

  17. Theory of the Infrared Absorption in the Ordered Solid Hydrogen

    OpenAIRE

    Jun-ichi, IGARASHI; Department of Physics, Osaka University

    1982-01-01

    The infrared absorption coefficient in the ordered solid orthohydrogen is calculated by making use of our anharmonic theory for libron (J=1 excitation) and roton (J=3 excitation). The momentum dependence of the transition amplitudes has properly been taken into account in conformity with our formalism. The shape of vibrational bands including J=1,3 rotational excitations is figured out in good agreement with the experiment by Boggs, Clouter and Welsh. A similar study has also been done for th...

  18. Assessment of S-NPP VIIRS band-to-band registration using Earth-scene features

    Science.gov (United States)

    Link, Daniel; Wang, Zhipeng; Xiong, Xiaoxiong

    2017-09-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) is currently operating onboard the Suomi National Polarorbiting Partnership (S-NPP) spacecraft. VIIRS records Earth imagery with spectral bands ranging from 0.4 to 12.2 micrometers at a combination of resolutions. Five imaging bands (I1-5) have a 375 m spatial resolution at nadir, which is half of the 750 m resolution of the 16 moderate resolution bands (M1-16). These bands are mounted according to their wavelengths at three separate Focal Plane Assemblies (FPA). The proper spatial registration among imaging bands is required to create multi-spectral images and analyses. Measurement of the band-to-band registration (BBR) is a determination of how well these bands are coincident. Using an external target such as the moon has proven to be a valid method and has been thoroughly investigated using VIIRS raw data record (RDR). Calibrated VIIRS radiometric data has been investigated using normalized mutual information (NMI) for BBR and shown stable results, by focusing on high-contrast shoreline sites. However, these results focus on a relatively small number of observations. We have previously reported analyses using earth-scene targets to determine BBR for MODIS instruments. This approach focuses on an African Desert site with high contrast spots generated through agricultural pivot irrigation. Using the near-daily observations provided by the VIIRS instrument, we investigate a large data set and track the BBR stability over the VIIRS mission. We discuss our results and compare them with prelaunch measurements and design specifications.

  19. Head and hand detuning effect study of narrow-band against wide-band mobile phone antennas

    DEFF Research Database (Denmark)

    Bahramzy, Pevand; Pedersen, Gert Frølund

    2014-01-01

    Wide-band (WB) and narrow-band (NB) antennas in terms of performance are compared, when interacting with the user’s right head and hand (RHH). The investigations are done through experimental measurements, using standardised head phantom and hand. It is shown that WB antennas detune more than NB ...

  20. K-band spectroscopic metallicities and temperatures of M-dwarf stars

    Directory of Open Access Journals (Sweden)

    Rojas-Ayala Bárbara

    2013-04-01

    Full Text Available I present the metallicity and effective temperature techniques developed for M dwarf stars by Rojas-Ayala et al. (2010, 2012. These techniques are based on absorption features present in the modest resolution K-band spectra (R∼2700 of M dwarfs and have been calibrated using FGK+M dwarf pairs and synthetic atmosphere models. The H2O-K2 index seems to overestimate the effective temperatures of M dwarfs when compared to interferometric measurements. The metallicity distribution of the M dwarf host candidates by the Kepler Mission hints that jovian-size planets form preferentially around solar and super-solar metallicity environments, while small rocky planet host exhibit a wide range of metallicities, just like in their solar-type counterparts.

  1. The 890 nm Methane Band: Line by Line Parameters for the Outer Solar System

    Science.gov (United States)

    Benner, D. Chris; O'Brien, J. J.; Shaji, S.; Malathy Devi, V.; Spickler, P. T.; Houck, C. P.; Coakley, J. A.; Haga, K. J.; Dolph, J. D.

    2010-10-01

    The near infrared bands of methane were the first observed in the outer planets and Titan. With the very long paths of rays within the atmospheres of these objects, scattering, pressure and temperature inhomogeneities are important. The spectrum of methane is very complex and long laboratory gas cells are difficult to cool to outer solar system temperatures. The absorption is usually modeled statistically. Violations of the modeling assumptions cause poor extrapolations of simulations based upon laboratory parameters. These band models generally do not provide transmissions that are multiplicative, so proper modeling of scattering and inhomogeneous atmospheres is not possible. The Intra Cavity Laser Spectrometer of the University of Missouri, St. Louis obtained low temperature (99-161K), low pressure ( few Torr), long path (few km) and high resolution ( 0.01 cm-1 HWHM) spectra of methane covering the entire 890 nm feature (10925-11500 cm-1), the deepest band below 1.1 µm. At these temperatures fewer spectral lines are visible and the Doppler width is substantially smaller than at room temperature. The result is a dense, but manageable spectrum from which line positions, intensities and lower state energies are derived on a line by line basis by the William and Mary multispectrum nonlinear least squares fitting technique. For temperatures less than 160K, simulation of the spectrum at infinite resolution is possible. Simulations at various physical conditions will be shown and compared to band models and other laboratory spectra. Support at William and Mary was provided by NASA through grant NNX08AF06G. Support at UM, St. Louis provided by NASA through grant NAG5-12013, from NSF through grant CHE-0213356 and by the University of Missouri Research Board. Partial support at Bridgewater College was provided by its Martin Science Research Institute and from an AAS Small Research Grant.

  2. Dual-band infrared camera

    Science.gov (United States)

    Vogel, H.; Schlemmer, H.

    2005-10-01

    Every year, numerous accidents happen on European roads due to bad visibility (fog, night, heavy rain). Similarly, the dramatic aviation accidents of year 2001 in Milan and Zurich have reminded us that aviation safety is equally affected by reduced visibility. A dual-band thermal imager was developed in order to raise human situation awareness under conditions of reduced visibility especially in the automotive and aeronautical context but also for all transportation or surveillance tasks. The chosen wavelength bands are the Short Wave Infrared SWIR and the Long Wave Infrared LWIR band which are less obscured by reduced visibility conditions than the visible band. Furthermore, our field tests clearly show that the two different spectral bands very often contain complementary information. Pyramidal fusion is used to integrate complementary and redundant features of the multi-spectral images into a fused image which can be displayed on a monitor to provide more and better information for the driver or pilot.

  3. AVHRR Surface Temperature and Narrow-Band Albedo Comparison with Ground Measurements for the Greenland Ice Sheet

    Science.gov (United States)

    Haefliger, M.; Steffen, K.; Fowler, C.

    1993-01-01

    An ice-surface temperature retrieval algorithm for the Greenland ice sheet was developed using NOAA 11 thermal radiances from channels 4 and 5. Temperature, pressure and humidity profiles, cloud observations and skin temperatures from the Swiss Federal Institute of Technology (ETH) camp, located at the equilibrium line altitude at 49 deg17 min W, 69 deg 34 min N, were used in the LOWTRAN 7 model. Through a statistical analysis of daily clear sky profiles, the coefficients that correct for the atmospheric effects were determined for the ETH-Camp field season (May to August). Surface temperatures retrieved by this method were then compared against the in situ observations with a maximum difference of 0.6 K. The NOAA 11 narrow-band planetary albedo values for channels 1 and 2 were calculated using pre-launch calibration coefficients. Scattering and absorption by the atmosphere were modelled with LOWTRAN 7. Then, narrow-band albedo values for the AVHRR visible and near infrared channels were compared with in situ high resolution spectral reflectance measurements. In the visible band (580-680 nm), AVHRR-derived narrow-band albedo and the in situ measurements corrected with radiative transfer model LOWTRAN 7 showed a difference of less than 2%. For the near infrared channel (725-1100 nm) the difference between the measured and modelled narrow-band albedo was 14%. These discrepancies could be either the result of inaccurate aerosol scattering modelling (lack of the in situ observation), or the result of sensor drift due to degradation.

  4. MULTIMAGNON ABSORPTION IN MNF2-OPTICAL ABSORPTION SPECTRUM.

    Science.gov (United States)

    The absorption spectrum of MnF2 at 4.2K in the 3900A region was measured in zero external fields and in high fields. Exciton lines with magnon ...sidebands are observed, accompanied by a large number of weak satellite lines. Results on the exciton and magnon absorptions are similar to those of...McClure et al. The satellite lines are interpreted as being multi- magnon absorptions, and it is possible to fit the energy of all the absorptions with

  5. Some aspects of coupling-induced sound absorption in enclosures.

    Science.gov (United States)

    Sum, K S; Pan, J

    2003-08-01

    It is known that the coupling between a modally reactive boundary structure of an enclosure and the enclosed sound field induces absorption in the sound field. However, the effect of this absorption on the sound-field response can vary significantly, even when material properties of the structure and dimensions of the coupled system are not changed. Although there have been numerous investigations of coupling between a structure and an enclosed sound field, little work has been done in the area of sound absorption induced by the coupling. Therefore, characteristics of the absorption are not well understood and the extent of its influence on the behavior of the sound-field response is not clearly known. In this paper, the coupling of a boundary structure and an enclosed sound field in frequency bands above the low-frequency range is considered. Three aspects of the coupling-induced sound absorption are studied namely, the effects of exciting either the structure or the sound field directly, damping in the uncoupled sound field and damping in the uncoupled structure. The results provide an understanding of some features of the coupling-induced absorption and its significance to the sound-field response.

  6. Manipulation of enhanced absorption with tilted hexagonal boron nitride slabs

    Science.gov (United States)

    Wu, Xiaohu; Fu, Ceji

    2018-04-01

    The wavevector of electromagnetic wave propagation in a hexagonal boron nitride (hBN) slab can be controlled by tilting its optical axis. This property can be used to manipulate the absorption in a hBN slab. By carefully analyzing the dependence of the absorptivity of a thin hBN slab on the tilted angle of its optical axis, we propose a structure that can realize great absorptivity enhancement in a band by stacking hBN slabs of different tilted angles. Our numerical results show that the absorptivity of a structure made of 91 stacked hBN slabs can be achieved higher than 0.94 in the wavenumber range from 1367 to 1580 cm-1 when the tilted angles of the slabs are properly arranged. The strong absorption is attributed to the combination of impedance matching at the slab interfaces and enlarged wavevectors in the slabs. This work reveals a novel way to realize strong absorption with anisotropic materials for applications in areas such as thermal radiative energy harvesting and conversion.

  7. Microwave absorption behavior in Cr2O3 nanopowders

    International Nuclear Information System (INIS)

    Montiel, H.; Alvarez, G.; Conde-Gallardo, A.; Zamorano, R.

    2015-01-01

    Highlights: • We have investigated the microwave power absorption in Cr 2 O 3 nanopowders. • EMR spectra show the contributions of the core and the surface of the nanoparticles. • MAMMAS detected an antiferro-paramagnetic transition due to core of the nanoparticles. • LFMA signal is associated with the ferromagnetic order on the surface of the nanoparticles. - Abstract: We have investigated the microwave power absorption at X-band (8.8–9.8 GHz) in Cr 2 O 3 nanopowders, for the 294–400 K temperature range. For all temperatures, two different kinds of microwave absorptions are observed: the electron magnetic resonance (EMR) at high magnetic field and the low-field microwave absorption (LFMA) around zero field. EMR spectrum can be separated in two contributions associated with two different resonant absorption modes, where this result is interpreted as the combination of two different magnetic phases; corresponding to the core (mode A) and the surface (mode B) of the Cr 2 O 3 nanoparticles. Also, we have detected the onset of the antiferro-paramagnetic transition in resonant mode A, which is characteristic of Cr 2 O 3 samples; being confirmed the magnetic transition by means of the magnetically modulated microwave absorption spectroscopy (MAMMAS). Additionally, the temperature behaviors of the resonant mode B and the LFMA signal are associated with a ferromagnetic state on the surface of the Cr 2 O 3 nanoparticles

  8. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference ...

  9. Analyzing Water's Optical Absorption

    Science.gov (United States)

    2002-01-01

    A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.

  10. Atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Haswell, S.J.

    1991-01-01

    Atomic absorption spectroscopy is now well established and widely used technique for the determination of trace and major elements in a wide range analyte types. There have been many advances in the atomic spectroscopy over the last decade and for this reason and to meet the demand, it was felt that there was a need for an updated book. Whilst interest in instrumental design has tended to dominate the minds of the spectrocopist, the analyst concerned with obtaining reliable and representative data, in diverse areas of application, has been diligently modifying and developing sample treatment and instrumental introduction techniques. Such methodology is de fundamental part of analysis and form the basis of the fourteen application chapters of this book. The text focuses in the main on AAS; however, the sample handling techniques described are in many cases equally applicable to ICP-OES and ICP-MS analysis. (author). refs.; figs.; tabs

  11. Determination of the Boundary Transition Temperatures in Polypropylene on the Basis of Measurements in the Terahertz Band

    Science.gov (United States)

    Kitai, M. S.; Nazarov, M. M.; Nedorezova, P. M.; Shkurinov, A. P.

    2017-10-01

    We propose a method for determination of the boundary temperatures of transitions in the structure of polymers by means of analyzing the refractive index of these materials in the terahertz band. The temperatures of glass transition, crystallization, and melting are determined experimentally for isotactic and syndiotactic polypropylenes. Such polymers have low absorption coefficients in the terahertz band. The behavior of intermolecular oscillations of the macromolecules, which are active in polymer spectra in this frequency band, is analyzed.

  12. Local structures and electronic band states of α-Fe2O3 polycrystalline particles included in the red-color overglazes and the transparent glazes of the Kakiemon-style porcelains by means of X-ray absorption spectra (II)

    International Nuclear Information System (INIS)

    Hidaka, M.; Kumara, L.S.R.; Wijesundera, R.P.; Sung, Nark Eon

    2009-01-01

    Kakiemon-style porcelain is mainly characterized by the porcelain body of white color or milky-white color and the elegant and bright patterns of the colored overglazes on its white body. The porcelains were first developed and completed by Kakiemon-kiln family in 1650-80's. The red-color overglazes and the transparent glazes of the present porcelain pieces, which were produced in the early 17 th century to the middle 18 th century, have been investigated by means of X-ray absorption spectrum using synchrotron radiation. The structure of a lpha - Fe 2 O 3 as red-color emission element is slightly deformed in the red-color overglazes by the other surrounding oxides (SiO 2 , Al 2 O 3 , K 2 O, Na 2 O, Mg O, Pb O), and/or the new complexes of (SiO 2 -Al 2 O 3 ,) systems constructed by the raw materials. The Fe ions in the transparent glazes are in the glass-state with the other oxides. However, the electronic valence, Fe 3+ , of Fe ions is the same with that of the a lpha - Fe 2 O 3 in the red-color overglazes. The lead oxides (Pb O, Pb 3 O 4 ) used in the Edo period to increase the brightness in the fritted red-color overglazes were perfectly decomposed, and Pb ions were in the glass-state of the porcelains. (author)

  13. Spectroscopic study of small absorptions in optical coatings

    Science.gov (United States)

    Hansen, W. N.

    1982-07-01

    This report concerns research performed by the Utah University surface physics group for the Air Force Weapons Laboratory (AFWL), Kirtland Air Force Base, New Mexico. It is a supplement to AFWL-TR-79-197. It reports the continued study of thorium fluoride (ThF4) as an optical coating, showing that the moisture found in the ThF4 films probably originated from the preparation itself, and that ThF4 may not degrade by moisture absorption from the atmosphere as rapidly as previously thought. Further advances are reported in the characterization procedures themselves, including computer methods for data handling. New procedures were instituted for determining the optical constants of liquids. To test the procedures, the optical constants of liquid water were determined and compared with values found in literature. The procedures used are reported. A sample of Si3N4 film on germanium was analyzed spectroscopically. The dominant feature was a large infrared band revealing the presence of large amounts of silicon hydride. Finally, new procedures are reported for determining impurity concentrations in optical thin films which takes into account the local electromagnetic field strength seen by an impurity in a known optical material as matrix.

  14. Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    The design of a flow injection/sequential injection (FIA/SIA) on-line preconcentration system incorporating a renewable microcolumn with ion-exchange beads and interfaced with an electrothermal atomic absorption spectrometry (ETAAS) detector is described, and its practical applicability.......4% for the procedure in which the loaded beads are transported directly to the graphite furnace for pyrolysis and atomization, and even improved in comparison to the traditional unidirectional and bidirectional repetitive elution procedures which under comparable conditions yield R.S.D.-values of 5.8 and 4...

  15. Metamaterials for perfect absorption

    CERN Document Server

    Lee, Young Pak; Yoo, Young Joon; Kim, Ki Won

    2016-01-01

    This book provides a comprehensive overview of the theory and practical development of metamaterial-based perfect absorbers (MMPAs). It begins with a brief history of MMPAs which reviews the various theoretical and experimental milestones in their development. The theoretical background and fundamental working principles of MMPAs are then discussed, providing the necessary background on how MMPAs work and are constructed. There then follows a section describing how different MMPAs are designed and built according to the operating frequency of the electromagnetic wave, and how their behavior is changed. Methods of fabricating and characterizing MMPAs are then presented. The book elaborates on the performance and characteristics of MMPAs, including electromagnetically-induced transparency (EIT). It also covers recent advances in MMPAs and their applications, including multi-band, broadband, tunability, polarization independence and incidence independence. Suitable for graduate students in optical sciences and e...

  16. SINGLE-BAND, TRIPLE-BAND, OR MULTIPLE-BAND HUBBARD MODELS

    NARCIS (Netherlands)

    ESKES, H; SAWATZKY, GA

    1991-01-01

    The relevance of different models, such as the one-band t-J model and the three-band Emery model, as a realistic description of the electronic structure of high-T(c) materials is discussed. Starting from a multiband approach using cluster calculations and an impurity approach, the following

  17. Critical discussion on the UV absorption properties of Earth's atmosphere

    Science.gov (United States)

    Döhring, Thorsten

    2017-08-01

    Sun's ultraviolet radiation is classified into UV-A, UV-B, and UV-C bands. Thereby UV-A passes through Earth's atmosphere, while UV-B is partially absorbed by ozone. The limitations of the commonly accepted statement, that UV-C is always completely absorbed by Earth's atmosphere, are discussed critically. Below 200 nm the solar spectrum is strongly absorbed by molecular oxygen. The stratospheric ozone layer has strong absorption between 200 nm and 300 nm. However, the "ozone hole" increases UV-B radiation just below 300 nm and may also open a transmitting atmospheric window for harmful UV-C at the overlap region between oxygen absorption and ozone absorption.

  18. Enhancing THz Absorption using Thin-Film Multilayer Stacks

    Science.gov (United States)

    Grbovic, Dragoslav; Bolakis, Christos; Karunasiri, Gamani

    2010-03-01

    Terahertz imaging has seen significant proliferation in recent years. This band of electromagnetic spectrum has been underutilized for a long time due to the lack of sufficiently powerful sources and sensitive detectors. Because of virtually harmless effects on living tissue, terahertz (THz) radiation is attractive for various applications, ranging from non-invasive medical diagnostics to detection of concealed weapons. Our work focuses on identifying materials, or more specifically a stack of thin-films with increased absorption in the band of interest. In this work, we demonstrate a method that combines finite element modeling, thin-film deposition and experimental characterization to create highly-absorptive multi-layer stacks. Finite element modeling is used to simulate the absorption of a combination of thin dielectric and metallic films. Metals are deposited using e-beam evaporation and dielectric films using plasma enhanced chemical vapor deposition (PECVD). The simulated and measured THz absorption characteristics of the composite thin-film multilayer stacts will be presented.

  19. Broadening microwave absorption via a multi-domain structure

    Science.gov (United States)

    Liu, Zhengwang; Che, Renchao; Wei, Yong; Liu, Yupu; Elzatahry, Ahmed A.; Dahyan, Daifallah Al.; Zhao, Dongyuan

    2017-04-01

    Materials with a high saturation magnetization have gained increasing attention in the field of microwave absorption; therefore, the magnetization value depends on the magnetic configuration inside them. However, the broad-band absorption in the range of microwave frequency (2-18 GHz) is a great challenge. Herein, the three-dimensional (3D) Fe/C hollow microspheres are constructed by iron nanocrystals permeating inside carbon matrix with a saturation magnetization of 340 emu/g, which is 1.55 times as that of bulk Fe, unexpectedly. Electron tomography, electron holography, and Lorentz transmission electron microscopy imaging provide the powerful testimony about Fe/C interpenetration and multi-domain state constructed by vortex and stripe domains. Benefiting from the unique chemical and magnetic microstructures, the microwave minimum absorption is as strong as -55 dB and the bandwidth (spans 12.5 GHz ranging from 5.5 to 18 GHz. Morphology and distribution of magnetic nano-domains can be facilely regulated by a controllable reduction sintering under H2/Ar gas and an optimized temperature over 450-850 °C. The findings might shed new light on the synthesis strategies of the materials with the broad-band frequency and understanding the association between multi-domain coupling and microwave absorption performance.

  20. Broadening microwave absorption via a multi-domain structure

    Directory of Open Access Journals (Sweden)

    Zhengwang Liu

    2017-04-01

    Full Text Available Materials with a high saturation magnetization have gained increasing attention in the field of microwave absorption; therefore, the magnetization value depends on the magnetic configuration inside them. However, the broad-band absorption in the range of microwave frequency (2-18 GHz is a great challenge. Herein, the three-dimensional (3D Fe/C hollow microspheres are constructed by iron nanocrystals permeating inside carbon matrix with a saturation magnetization of 340 emu/g, which is 1.55 times as that of bulk Fe, unexpectedly. Electron tomography, electron holography, and Lorentz transmission electron microscopy imaging provide the powerful testimony about Fe/C interpenetration and multi-domain state constructed by vortex and stripe domains. Benefiting from the unique chemical and magnetic microstructures, the microwave minimum absorption is as strong as −55 dB and the bandwidth (<−10 dB spans 12.5 GHz ranging from 5.5 to 18 GHz. Morphology and distribution of magnetic nano-domains can be facilely regulated by a controllable reduction sintering under H2/Ar gas and an optimized temperature over 450–850 °C. The findings might shed new light on the synthesis strategies of the materials with the broad-band frequency and understanding the association between multi-domain coupling and microwave absorption performance.

  1. Nonlinear effects in collective absorption

    International Nuclear Information System (INIS)

    Uenoyama, Takeshi; Mima, Kunioki; Watanabe, Tsuguhiro.

    1981-01-01

    The collective absorption of high intensity laser radiation is analyzed numerically. Density profile modification due to the ponderomotive force associating laser radiation and the excited electron plasma waves is self-consistently taken into account, and the intensity dependences of the absorption efficiency are obtained. In the high intensity regime, the absorption efficiency is found to be strongly enhanced in the plasma without flow, but reduced with supersonic flow. (author)

  2. Atomic absorption spectrophotometry in perspective

    International Nuclear Information System (INIS)

    Soffiantini, V.

    1981-01-01

    Atomic absorption spectrophotometry is essentially an analytical technique used for quantitative trace metal analysis in a variety of materials. The speed and specificity of the technique is its greatest advantage over other analytical techniques. What atomic absorption spectrophotometry can and cannot do and its advantages and disadvantages are discussed, a summary of operating instructions are given, as well as a summary of analytical interferences. The applications of atomic absorption spectrophotometry are also shortly discussed

  3. The Effect of Sandblasting on the Retention of Orthodontic Bands: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Vishal A Nalawade

    2013-01-01

    Interpretation and conclusion: GIC requires the highest force to deband when compared with polycarboxylate and zinc phosphate cements when used on nonsandblasted bands. In-office sandblasting appears to be an efficient method to increase the retention of orthodontic bands.

  4. Optical band gap of Sn0⋅ 2Bi1⋅ 8Te3 thin films

    Indian Academy of Sciences (India)

    Sn0.2Bi1.8Te3 thin films were grown using the thermal evaporation technique on a (001) face of NaCl crystal as a substrate at room temperature. The optical absorption was measured in the wave number range 500–4000 cm-1. From the optical absorption data the band gap was evaluated and studied as a function of film ...

  5. Using Methane Absorption to Probe Jupiter's Atmosphere

    Science.gov (United States)

    1997-01-01

    Mosaics of a belt-zone boundary near Jupiter's equator in near-infrared light moderately absorbed by atmospheric methane (top panel), and strongly absorbed by atmospheric methane (bottom panel). The four images that make up each of these mosaics were taken within a few minutes of each other. Methane in Jupiter's atmosphere absorbs light at specific wavelengths called absorption bands. By detecting light close and far from these absorption bands, Galileo can probe to different depths in Jupiter's atmosphere. Sunlight near 732 nanometers (top panel) is moderately absorbed by methane. Some of the light reflected from clouds deep in Jupiter's troposphere is absorbed, enhancing the higher features. Sunlight at 886 nanometers (bottom panel) is strongly absorbed by methane. Most of the light reflected from the deeper clouds is absorbed, making these clouds invisible. Features in the diffuse cloud layer higher in Jupiter's atmosphere are greatly enhanced.North is at the top. The mosaic covers latitudes -13 to +3 degrees and is centered at longitude 282 degrees West. The smallest resolved features are tens of kilometers in size. These images were taken on November 5th, 1996, at a range of 1.2 million kilometers by the Solid State Imaging system aboard NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepo

  6. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  7. Band-notched ultrawide band antenna loaded with ferrite slab

    Science.gov (United States)

    Wang, Hao; Zong, Weihua; Sun, Nian X.; Lin, Hwaider; Li, Shandong

    2017-05-01

    In this paper, a novel technique to design a band-notched UWB antenna by using Yttrium Iron Garnet (YIG) ferrite is proposed. A printed slot UWB antenna with size of 21mm×26 mm×0.8 mm is adopted as a basic antenna. A piece of ferrite slab with size of 5 mm×10 mm×2 mm is attached on the feeding layer of the antenna to achieve band-notched characteristics. The measured -10 dB bandwidth of the antenna without ferrite slab is 2.91-10.98 GHz. With loading of ferrite slab, the bandwidth turns to 2.73-5.12 and 5.87-10.78 GHz. A band notch of 5.12- 5.87 GHz is achieved to filter WLAN 5 GHz (5.15-5.825 GHz) band. The proposed technique has virtue of easy fabrication and keeping antenna miniaturization.

  8. Local structures and electronic band states of {alpha}-Fe{sub 2}O{sub 3} polycrystalline particles in the glazes of the HIZEN celadons produced in the Edo period of Japan, by means of X-ray absorption spectra (II)

    Energy Technology Data Exchange (ETDEWEB)

    Hidaka, M.; Kumara, L.S.R. [Department of Physics, Graduate School of Science, Kyushu University, Fukuoka (Japan)], e-mail: hidaka@phys.kyushu-u.ac.jp; Ohashi, K. [The Kyushu Ceramic Museum, Arita, Saga (Japan); Wijesundera, R.P. [Department of Physics, University of Kelaniya, Kelaniya (Sri Lanka); Sugihara, S. [Radioisotope Center, Kyushu University, Fukuoka (Japan); Momoshima, N.; Kubuki, S. [Department of Chemical and Biological Engineering, Ube National College of Technology, Yamaguchi (Japan); Sung, N.E. [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang (Korea, Republic of)

    2011-04-15

    HIZEN celadon glazes produced in 1630's to 1790's (Edo period, Japan) have been investigated by means of X-ray absorption spectra (XAS) near a Fe-K edge by using synchrotron radiation and a Moessbauer spectrum. The XAS suggest that the local structure around Fe{sub 2}O{sub 3} fine powders is slightly different between the Izumiyama ceramics of mainly the Quartz-SiO{sub 2} and Ohkawachi ceramics of mainly the feldspar of (K,Na)Si{sub 3}O{sub 8} (Sanidine), and that the glazes of the HIZEN celadons include the Fe{sub 2}O{sub 3} fine powders in the glassy state, though the X-ray diffraction patterns of the glassy celadon glazes do not show any peaks of the Fe{sub 2}O{sub 3} structure. The Moessbauer spectrum suggests that the celadon glaze of Seiji (m) includes only Fe{sup 3+} ions, but not Fe{sup 2+} ions. This indicates the existence of Fe{sub 2}O{sub 3} in the celadon glaze. It is interpreted that the colored brightness of the HIZEN celadons is induced by the structural properties of the used raw celadon ceramics and the other transition-metal ions of Cr, Cu, Zn in the celadon glazes, but not by the chemical reaction from Fe{sub 2}O{sub 3} to Fe O under the deoxidising thermal treatment at higher temperature in a kiln. (author)

  9. Band-to-Band Tunneling Transistors: Scalability and Circuit Performance

    Science.gov (United States)

    2013-05-01

    55* MEDICI ...3.2.1 Tunneling Theory 3.3 Simulation Methods 3.3.1 MEDICI 3.3.2 Sentaurus Local Tunneling 3.3.3 Sentaurus Nonlocal Tunneling 3.4 Sentaurus...tunneling current. 3.3.1 MEDICI MEDICI is a one and two-dimensional simulator created by Synopsys, Inc. [18]. It contains a band-to-band

  10. Nonequilibrium absorption in semiconductors and the dynamical Franz-Keldysh effect

    DEFF Research Database (Denmark)

    Johnsen, Kristinn; Jauho, Antti-Pekka

    1997-01-01

    systems. Modulation above the band gap is weak in the 3D case but considerable fine structure is predicted for 1D and 2D systems. A characteristic feature of the dynamical Franz-Keldysh effect is that the absorption edge will be shifted up by an amount corresponding to the average kinetic energy......We theoretically study free electron light absorption for a sample which is placed in a strong, time-dependent uniform electric field. In the case of static fields one observes the Franz-Keldysh effect: finite absorption for photon energies below the band gap. We refer to this phenomenon...... as the Franz-Keldysh tail. Modulation of the spectra above the band gap is also found. These static effects are observed in both 3D, 2D and 1D systems. Our analysis, based on nonequilibrium Green function techniques, shows that an analogous effect takes place in time-dependent fields: the dynamical Franz...

  11. Polarized absorption spectra of aromatic radicals in stretched polymer film, 4. Radical ions of 9-substituted anthracenes. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Hiroshi; Nakamura, Hitoshi; Tanizaki, Yoshie; Nakajima, Keihachiro (Tokyo Inst. of Tech. (Japan). Faculty of Science)

    1982-11-01

    Radical ions of some 9-substituted anthracene derivatives have been prepared in polymer film by gamma -irradiation at 77 K. By use of the polarized absorption spectra of these radical ions, the absorption spectra have been resolved into two components (resolved spectra), the transition moments of which are polarized parallel to the molecular long and short axes, respectively. Correlation of the characteristic absorption bands is discussed briefly.

  12. The Red Edge Problem in asteroid band parameter analysis

    Science.gov (United States)

    Lindsay, Sean S.; Dunn, Tasha L.; Emery, Joshua P.; Bowles, Neil E.

    2016-04-01

    Near-infrared reflectance spectra of S-type asteroids contain two absorptions at 1 and 2 μm (band I and II) that are diagnostic of mineralogy. A parameterization of these two bands is frequently employed to determine the mineralogy of S(IV) asteroids through the use of ordinary chondrite calibration equations that link the mineralogy to band parameters. The most widely used calibration study uses a Band II terminal wavelength point (red edge) at 2.50 μm. However, due to the limitations of the NIR detectors on prominent telescopes used in asteroid research, spectral data for asteroids are typically only reliable out to 2.45 μm. We refer to this discrepancy as "The Red Edge Problem." In this report, we evaluate the associated errors for measured band area ratios (BAR = Area BII/BI) and calculated relative abundance measurements. We find that the Red Edge Problem is often not the dominant source of error for the observationally limited red edge set at 2.45 μm, but it frequently is for a red edge set at 2.40 μm. The error, however, is one sided and therefore systematic. As such, we provide equations to adjust measured BARs to values with a different red edge definition. We also provide new ol/(ol+px) calibration equations for red edges set at 2.40 and 2.45 μm.

  13. Laboratory confirmation of C60(+) as the carrier of two diffuse interstellar bands.

    Science.gov (United States)

    Campbell, E K; Holz, M; Gerlich, D; Maier, J P

    2015-07-16

    The diffuse interstellar bands are absorption lines seen towards reddened stars. None of the molecules responsible for these bands have been conclusively identified. Two bands at 9,632 ångströms and 9,577 ångströms were reported in 1994, and were suggested to arise from C60(+) molecules (ref. 3), on the basis of the proximity of these wavelengths to the absorption bands of C60(+) measured in a neon matrix. Confirmation of this assignment requires the gas-phase spectrum of C60(+). Here we report laboratory spectroscopy of C60(+) in the gas phase, cooled to 5.8 kelvin. The absorption spectrum has maxima at 9,632.7 ± 0.1 ångströms and 9,577.5 ± 0.1 ångströms, and the full widths at half-maximum of these bands are 2.2 ± 0.2 ångströms and 2.5 ± 0.2 ångströms, respectively. We conclude that we have positively identified the diffuse interstellar bands at 9,632 ångströms and 9,577 ångströms as arising from C60(+) in the interstellar medium.

  14. Thermodynamic performances of [mmim]DMP/Methanol absorption refrigeration

    Science.gov (United States)

    Chen, Wei; Liang, Shiqiang; Guo, Yongxian; Cheng, Keyong; Gui, Xiaohong; Tang, Dawei

    2012-12-01

    In order to study the theoretical cycle characteristic of [mmim]DMP (1-methyl-3-methylimidazolium dimethylphosphate) /methanol absorption refrigeration, the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T=280˜370 K and methanol mole fraction x= 0.529˜0.965. Thermodynamic performances of absorption refrigeration utilizing [mmim]DMP/methanol, LiBr/H2O and H2O/NH3 are investigated and compared with each other under the same operating conditions. From the results, some conclusions are obtained as follows: 1) the circulation ratio of the [mmim]DMP /methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration, but still can be acceptable and tolerable. 2) The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration, while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions. 3) The [mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.

  15. CO2 Capture from Flue Gas by Phase Transitional Absorption

    Energy Technology Data Exchange (ETDEWEB)

    Liang Hu

    2009-06-30

    A novel absorption process called Phase Transitional Absorption was invented. What is the Phase Transitional Absorption? Phase Transitional Absorption is a two or multi phase absorption system, CO{sub 2} rich phase and CO{sub 2} lean phase. During Absorption, CO{sub 2} is accumulated in CO{sub 2} rich phase. After separating the two phases, CO{sub 2} rich phase is forward to regeneration. After regeneration, the regenerated CO{sub 2} rich phase combines CO{sub 2} lean phase to form absorbent again to complete the cycle. The advantage for Phase Transitional Absorption is obvious, significantly saving on regeneration energy. Because CO{sub 2} lean phase was separated before regeneration, only CO{sub 2} rich phase was forward to regeneration. The absorption system we developed has the features of high absorption rate, high loading and working capacity, low corrosion, low regeneration heat, no toxic to environment, etc. The process evaluation shows that our process is able to save 80% energy cost by comparing with MEA process.

  16. Absorption from iron tablets given with different types of meals

    International Nuclear Information System (INIS)

    Hallberg, L.; Bjoern-Rasmussen, E.; Ekenved, G.; Garby, L.; Rossander, L.; Pleehachinda, R.; Suwanik, R.; Arvidsson, B.

    1978-01-01

    The absorption from iron tablets given with 5 types of meals was studied in 153 subjects. The meals were: a hamburger meal with beans and potatoes, a simple breakfast meal, a Latin American meal composed of black beans, rice and maize and two Southeast Asian meals composed of rice, vegetables, and spices served with and without fish. The groups were directly compared by relating the absorption from the iron tablets to the absorption from a standardized reference dose of iron given on an empty stomach. The composition of meals with respect to content of meat or fish or the presence of large amounts of phytates seemed to have no influence on the absorption of iron from tablets. The absorption from iron tablets was about 40% higher when they were given with rice meals than when they were given with the other meals studied. The average decrease in absorption by meals was about 50-60% based on a comparison when tablets were given on an empty stomach. When tablets from which the iron was released more slowly were used, the absorption increased by about 30% except when they were given with rice meals, where the absorption was unchanged. The differences among the meals in their effect on the absorption of iron from tablets thus disappeared when the slow-release tablets were given. (author)

  17. Gastric Band Port Site Fixation: Which Method Is Best?

    Directory of Open Access Journals (Sweden)

    Corinne E. Owers

    2015-01-01

    Full Text Available Laparoscopic adjustable gastric banding is a popular and successful bariatric surgical technique. Although short-term complications are few in number, long-term complications are more common. One such complication is flippage of the gastric band port. This study compares three popular methods of port fixation and demonstrates that fixation with nonabsorbable mesh helps to prevent port flippage when compared to other techniques, reducing the need for repositioning operations.

  18. Phytases for improved iron absorption

    DEFF Research Database (Denmark)

    Nielsen, Anne Veller Friis; Meyer, Anne S.

    2016-01-01

    Phytase enzymes present an alternative to iron supplements, because they have been shown to improve iron absorption by means of catalysing the degradation of a potent iron absorption inhibitor: phytic acid. Phytic acid is a hexaphosphate of inositol and is particularly prevalent in cereal grains...

  19. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  20. Multifunctional hybrids for electromagnetic absorption

    Energy Technology Data Exchange (ETDEWEB)

    Huynen, I. [Research Center in Micro and Nanoscopic Materials and Electronic Devices, CeRMiN, Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Information and Communications Technologies, Electronics and Applied Mathematics (ICTEAM), Microwave Laboratory, Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Quievy, N. [Institute of Condensed Matter and Nanosciences (IMCN), Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Bailly, C. [Research Center in Micro and Nanoscopic Materials and Electronic Devices, CeRMiN, Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Institute of Condensed Matter and Nanosciences (IMCN), Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Institute of Mechanics, Materials and Civil Engineering (iMMC), Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Bollen, P. [Information and Communications Technologies, Electronics and Applied Mathematics (ICTEAM), Microwave Laboratory, Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Institute of Condensed Matter and Nanosciences (IMCN), Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Institute of Mechanics, Materials and Civil Engineering (iMMC), Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Detrembleur, C. [Center for Education and Research on Macromolecules (CERM), University of Liege, Sart-Tilman B6a, 4000 Liege (Belgium); Eggermont, S.; Molenberg, I. [Information and Communications Technologies, Electronics and Applied Mathematics (ICTEAM), Microwave Laboratory, Universite catholique de Louvain, B-1348 Louvain-la-Neuve (Belgium); Thomassin, J.M.; Urbanczyk, L. [Center for Education and Research on Macromolecules (CERM), University of Liege, Sart-Tilman B6a, 4000 Liege (Belgium)

    2011-05-15

    Highlights: > EM absorption requires low dielectric constant and {approx}1 S/m electrical conductivity. > New hybrids were processed with CNT-filled polymer foam inserted in Al honeycomb. > The EM absorption in the GHz range is superior to any known material. > A closed form model is used to guide the design of the hybrid. > The architectured material is light with potential for thermal management. - Abstract: Electromagnetic (EM) interferences are ubiquitous in modern technologies and impact on the reliability of electronic devices and on living cells. Shielding by EM absorption, which is preferable over reflection in certain instances, requires combining a low dielectric constant with high electrical conductivity, which are antagonist properties in the world of materials. A novel class of hybrid materials for EM absorption in the gigahertz range has been developed based on a hierarchical architecture involving a metallic honeycomb filled with a carbon nanotube-reinforced polymer foam. The waveguide characteristics of the honeycomb combined with the performance of the foam lead to unexpectedly large EM power absorption over a wide frequency range, superior to any known material. The peak absorption frequency can be tuned by varying the shape of the honeycomb unit cell. A closed form model of the EM reflection and absorption provides a tool for the optimization of the hybrid. This designed material sets the stage for a new class of sandwich panels combining high EM absorption with mass efficiency, stiffness and thermal management.