WorldWideScience

Sample records for absorb 2-year outcomes

  1. Two years' outcome of thread lifting with absorbable barbed PDO threads: Innovative score for objective and subjective assessment.

    Science.gov (United States)

    Ali, Yasser Helmy

    2018-02-01

    Thread-lifting rejuvenation procedures have evolved again, with the development of absorbable threads. Although they have gained popularity among plastic surgeons and dermatologists, very few articles have been written in literature about absorbable threads. This study aims to evaluate two years' outcome of thread lifting using absorbable barbed threads for facial rejuvenation. Prospective comparative stud both objectively and subjectively and follow-up assessment for 24 months. Thread lifting for face rejuvenation has significant long-lasting effects that include skin lifting from 3-10 mm and high degree of patients' satisfaction with less incidence rate of complications, about 4.8%. Augmented results are obtained when thread lifting is combined with other lifting and rejuvenation modalities. Significant facial rejuvenation is achieved by thread lifting and highly augmented results are observed when they are combined with Botox, fillers, and/or platelet rich plasma (PRP) rejuvenations.

  2. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    Science.gov (United States)

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and

  3. 2-year patient-related versus stent-related outcomes

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Christiansen, Evald Høj

    2012-01-01

    years were further assessed with specific focus on patient-related composite (all death, all MI, or any revascularization) and stent-related composite outcomes (cardiac death, target vessel MI, or symptom-driven target lesion revascularization). A total of 1,390 patients were assigned to receive the EES......, and 1,384 patients were assigned to receive the SES. RESULTS: At 2 years, the composite primary endpoint occurred in 8.3% in the EES group and in 8.7% in the SES group (hazard ratio [HR]: 0.94, 95% confidence interval [CI]: 0.73 to 1.22). The patient-related outcome: 15.0% in the EES group versus 15.......80). CONCLUSIONS: At 2-year follow-up, the EES was found to be noninferior to the SES with regard to both patient-related and stent-related clinical outcomes. (Scandinavian Organization for Randomized Trials With Clinical Outcome IV [SORT OUT IV]; NCT00552877)....

  4. Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent: 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials.

    Science.gov (United States)

    Campos, Carlos M; Caixeta, Adriano; Franken, Marcelo; Bartorelli, Antonio L; Whitbourn, Robert J; Wu, Chiung-Jen; Li Paul Kao, Hsien; Rosli, Mohd Ali; Carrie, Didier; De Bruyne, Bernard; Stone, Gregg W; Serruys, Patrick W; Abizaid, Alexandre

    2018-02-15

    to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Clinical outcomes of patients with diabetes mellitus treated with Absorb bioresorbable vascular scaffolds: a subanalysis of the European Multicentre GHOST-EU Registry.

    Science.gov (United States)

    Capranzano, Piera; Capodanno, Davide; Brugaletta, Salvatore; Latib, Azeem; Mehilli, Julinda; Nef, Holger; Gori, Tommaso; Lesiak, Maciej; Geraci, Salvatore; Pyxaras, Stelios; Mattesini, Alessio; Münzel, Thomas; Araszkiewicz, Aleksander; Caramanno, Giuseppe; Naber, Christoph; Di Mario, Carlo; Sabatè, Manel; Colombo, Antonio; Wiebe, Jens; Tamburino, Corrado

    2018-02-15

    Data on the clinical performance of bioresorbable scaffolds in patients with diabetes mellitus (DM) are still limited. The present study reported 1-year clinical outcomes associated with the use of everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS; Abbott Vascular, Santa Clara, CA) in DM patients. This was a subanalysis from the GHOST-EU (Gauging coronary Healing with biOresorbable Scaffolding plaTforms in Europe) multicenter retrospective registry including patients treated with Absorb BVS between November 2011 and September 2014. In this study, a comparative analysis stratified according to DM was performed. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, target-vessel myocardial infarction (MI) and clinically-driven target-lesion revascularization (TLR). A total of 1,477 patients were treated with 2,224 Absorb BVS; 381 (25.8%) and 1,096 (74.2%) patients were with and without DM, respectively. The 1-year rate of TLF was higher among patients with DM (7.8%) than those without DM (4.3%); the increase in TLF was driven by TLR (6.5% vs. 3.3%, P = 0.009); no significant differences in cardiac death (1.1% vs. 0.9%, P = 0.68) and target-vessel MI (3.1% vs. 2.2%, P = 0.38) were observed, respectively. Definite/probable scaffold thrombosis rate tended to be higher among patients with DM than those without DM (3.0% vs. 1.7%, P = 0.14, respectively). Absorb BVS use in patients with DM was associated with increased 1-year TLF and scaffold thrombosis compared with non-diabetes patients. © 2017 Wiley Periodicals, Inc.

  6. Liquid absorber experiments in ZED-2

    International Nuclear Information System (INIS)

    McDonnell, F.N.

    1975-07-01

    A set of liquid absorber experiments was performed in ZED-2 to provide data with which to test the adequacy of calculational methods for zone controller and refuelling studies associated with advanced reactor concepts. The absorber consisted of a full length aluminum tube, containing either i)H 2 O, ii)H 2 O + boron (2.5 mg/ml) or iii)H 2 O + boron (8.0 mg/ml). The tube was suspended vertically at interstitial or in-channel locations. A U-tube absorber was also simulated using two absorber tubes with appropriate spacers. Experiments were carried out at two different square lattice pitches, 22.86 and 27.94 cm. Measurements were made of the reactivity effects of the absorbers and, in some cases, of the detailed flux distribution near the perturbation. The results from one calculational method, the source-sink approach, were compared with the data from selected experiments. (author)

  7. Crestal Sinus Augmentation with Recombinant Human Bone Morphogenetic Protein 2: Clinical and Radiographic Outcomes of 2-Year Pilot Trial.

    Science.gov (United States)

    Kuchler, Ulrike; Rudelstorfer, Claudia M; Barth, Barbara; Tepper, Gabor; Lidinsky, Dominika; Heimel, Patrick; Watzek, Georg; Gruber, Reinhard

    Recombinant human bone morphogenetic protein 2 (rhBMP-2) together with an absorbable collagen carrier (ACS) was approved for augmentation of the maxillary sinus prior to implant placement. The original registration trial was based on a lateral window approach. Clinical outcomes of crestal sinus augmentation with rhBMP-2 have not been reported so far. An uncontrolled pilot trial in which seven patients with a residual maxillary height below 5 mm were enrolled to receive crestal sinus augmentation with rhBMP-2/ACS was conducted. Elevation of the sinus mucosa was performed by gel pressure. Primary endpoints were the gain in augmentation height and volume measured by computed tomography after 6 months. Evaluation of bone quality at the time of implant placement was based on histology. Secondary endpoints were the clinical and radiologic evaluation of the implants and patient satisfaction by visual analog scale (VAS) at the 2-year follow-up. Median gain in augmentation height was 7.2 mm (range 0.0 to 17.5 mm). Five patients gained at least 5 mm of bone height. Two patients with a perforation of the sinus mucosa failed to respond to rhBMP-2/ACS and underwent lateral window augmentation. The median gain in augmentation volume of the five patients was 781.3 mm³ (range 426.9 to 1,242.8 mm³). Biopsy specimens showed a cancellous network consisting of primary plexiform bone with little secondary lamellar bone. After 2 years, implants were in function with no signs of inflammation or peri-implant bone loss. Patients were satisfied with the esthetic outcomes and chewing function. This pilot clinical trial supports the original concept that rhBMP-2/ACS supports bone formation, also in crestal sinus augmentation, and emphasizes the relevance of the integrity of the sinus mucosa to predict the bone gain.

  8. Mid-term outcomes of the Absorb BVS versus second-generation DES: A systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Cordula M Felix

    Full Text Available Bioresorbable Vascular Scaffolds (BVS were introduced to overcome some of the limitations of drug-eluting stent (DES for PCI. Data regarding the clinical outcomes of the BVS versus DES beyond 2 years are emerging.To study mid-term outcomes.We searched online databases (PubMed/Medline, Embase, CENTRAL, several websites, meeting presentations and scientific session abstracts until August 8th, 2017 for studies comparing Absorb BVS with second-generation DES. The primary outcome was target lesion failure (TLF. Secondary outcomes were all-cause mortality, myocardial infarction, target lesion revascularization (TLR and definite/probable device thrombosis. Odds ratios (ORs with 95% confidence intervals (CIs were derived using a random effects model.Ten studies, seven randomized controlled trials and three propensity-matched observational studies, with a total of 7320 patients (BVS n = 4007; DES n = 3313 and a median follow-up duration of 30.5 months, were included. Risk of TLF was increased for BVS-treated patients (OR 1.34 [95% CI: 1.12-1.60], p = 0.001, I2 = 0%. This was also the case for all myocardial infarction (1.58 [95% CI: 1.27-1.96], p1 year device thrombosis was 6.10 [95% CI: 1.40-26.65], p = 0.02.At mid-term follow-up, BVS was associated with an increased risk of TLF, MI, TLR and definite/probable device thrombosis, but this did not result in an increased risk of all-cause mortality.

  9. Relative size predicts competitive outcome through 2 million years.

    Science.gov (United States)

    Liow, Lee Hsiang; Di Martino, Emanuela; Krzeminska, Malgorzata; Ramsfjell, Mali; Rust, Seabourne; Taylor, Paul D; Voje, Kjetil L

    2017-08-01

    Competition is an important biotic interaction that influences survival and reproduction. While competition on ecological timescales has received great attention, little is known about competition on evolutionary timescales. Do competitive abilities change over hundreds of thousands to millions of years? Can we predict competitive outcomes using phenotypic traits? How much do traits that confer competitive advantage and competitive outcomes change? Here we show, using communities of encrusting marine bryozoans spanning more than 2 million years, that size is a significant determinant of overgrowth outcomes: colonies with larger zooids tend to overgrow colonies with smaller zooids. We also detected temporally coordinated changes in average zooid sizes, suggesting that different species responded to a common external driver. Although species-specific average zooid sizes change over evolutionary timescales, species-specific competitive abilities seem relatively stable, suggesting that traits other than zooid size also control overgrowth outcomes and/or that evolutionary constraints are involved. © 2017 John Wiley & Sons Ltd/CNRS.

  10. Clinical outcomes of pars plicata anterior vitrectomy: 2-year results

    Directory of Open Access Journals (Sweden)

    Priya Narang

    2015-01-01

    Full Text Available Purpose: To demonstrate the safety and outcome of a surgical approach that uses pars plicata site for anterior vitrectomy during phacoemulsification procedure complicated by posterior capsule rupture and residual cortical matter. Design: Single center, retrospective, interventional, noncomparative study. Materials and Methods: Medical records of a consecutive series of 35 eyes of 35 patients who underwent pars plicata anterior vitrectomy (PPAV were reviewed. The main outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA, early and late postoperative complications and intraocular pressure (IOP. Ultrasound biomicroscopic (UBM evaluation of sclerotomy site and spectral domain optical coherence tomography analysis for central macular thickness (CMT was performed. The final visual outcome at 2 years was evaluated. Results: At 2 years follow-up, the mean postoperative UDVA (logarithm of the minimum angle of resolution [logMAR] and CDVA (logMAR was 0.49 ± 0.26 and 0.19 ± 0.14, respectively. There was no significant change in the IOP (P = 0.061 and the mean CMT at 2 years was 192.5 ± 5.54 mm. The postoperative UBM image of the sclerotomy site at 8 weeks demonstrated a clear wound without any vitreous adhesion or incarceration. Intraoperative hyphema was seen in 1 (2.8% case and postoperative uveitis was seen in 2 (5.7% cases, which resolved with medications. No case of an iatrogenic retinal break or retinal detachment was reported. Conclusions: PPAV enables a closed chamber approach, allows thorough cleanup of vitreous in the pupillary plane and anterior chamber and affords better access to the subincisional and retropupillary cortical remnant with a significant visual outcome and an acceptable complication rate.

  11. Operation for recurrent cystocele with anterior colporrhaphy or non-absorbable mesh: patient reported outcomes

    DEFF Research Database (Denmark)

    Nüssler, Emil Karl; Greisen, Susanne; Kesmodel, Ulrik Schiøler

    2013-01-01

    Abstract INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare patient reported outcomes and complications after repair of recurrent anterior vaginal wall prolapse in routine health care settings using standard anterior colporrhaphy or non-absorbable mesh. METHODS: The study is based...... on prospective data from the Swedish National Register for Gynaecological Surgery. 286 women were operated on for recurrent anterior vaginal wall prolapse in 2008-2010; 157 women had an anterior colporrhaphy and 129 were operated on with a non-absorbable mesh. Pre-, and perioperative data were collected from...... (0.6 %) in the anterior colporrhaphy group (p = 0.58). The infection rate was higher after mesh (8.5 %) than after anterior colporrhaphy (2.5 %; OR 3.19 ; 1.07-14.25). CONCLUSION: Implantation of synthetic mesh during operation for recurrent cystocele more than doubled the cure rate, whereas...

  12. Efficacy and Safety of the Absorb Everolimus-Eluting Bioresorbable Scaffold for Treatment of Patients With Diabetes Mellitus: Results of the Absorb Diabetic Substudy.

    Science.gov (United States)

    Kereiakes, Dean J; Ellis, Stephen G; Kimura, Takeshi; Abizaid, Alexandre; Zhao, Weiying; Veldhof, Susan; Vu, Minh-Thien; Zhang, Zhen; Onuma, Yoshinobu; Chevalier, Bernard; Serruys, Patrick W; Stone, Gregg W

    2017-01-09

    The study sought to evaluate the efficacy and safety of the Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Abbott Park, Illinois) in patients with diabetes mellitus. Randomized, controlled trials have demonstrated comparable clinical outcomes following percutaneous coronary intervention with either Absorb BVS or metallic Xience everolimus-eluting stent. However, these trials lack power required to provide reliable treatment effect estimates in this high-risk population. In a pre-specified, powered analysis, patients with diabetes who received ≥1 Absorb were pooled from the ABSORB II, III, and JAPAN randomized trials and from the single arm ABSORB EXTEND registry. The study composite primary endpoint was target lesion failure (TLF) at 1 year following Absorb BVS compared with a performance goal of 12.7%. Among 754 diabetic patients included in analysis (27.3% insulin treated), the 1-year TLF rate was 8.3% (upper 1-sided 95% confidence limit: 10.1%; p = 0.0001 vs. performance goal). Scaffold thrombosis (definite or probable) was observed in 2.3% of patients. Multivariable regression identified older age, insulin treatment, and smaller pre-procedure reference vessel diameter as significant independent predictors of 1-year TLF. The Absorb diabetic substudy suggests efficacy and safety of the Absorb BVS for treatment of patients with diabetes mellitus. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Serendipitous discovery of warm absorbers in the Seyfert 2 galaxy IRAS 18325-5926

    International Nuclear Information System (INIS)

    Zhang Shuinai; Gu Qiusheng; Peng Zhixin; Ji Li

    2011-01-01

    Warm absorption is a common phenomenon in Seyfert 1s and quasars, but is rare in Seyfert 2s. We report the detection of warm absorbers with high energy resolution in the Seyfert 2 galaxy IRAS 18325-5926 for the first time with Chandra HETGS spectra. An intrinsic absorbing line system with an outflow velocity ∼ 400 km s -1 was found, which is contributed by two warm absorbers with FWHM of 570 km s -1 and 1360 km s -1 , respectively. The two absorbers were adjacent, and moving transversely across our line of sight. We constrained the distance between the center and the absorbers to be a small value, suggesting that the absorbers may originate from the highly ionized accretion disk wind ejected five years ago. The perspective of this type 2 Seyfert provides the best situation in which to investigate the vertical part of the funnel-like outflows. Another weak absorbing line system with zero redshift was also detected, which could be due to Galactic absorption with very high temperature or an intrinsic outflow with a very high velocity ∼ 6000 km s -1 . (research papers)

  14. Motor Testing at 1 Year Improves the Prediction of Motor and Mental Outcome at 2 Years after Perinatal Hypoxic-Ischaemic Encephalopathy

    Science.gov (United States)

    van Schie, Petra Em; Becher, Jules G.; Dallmeijer, Annet J.; Barkhof, Frederik; van Weissenbruch, Mirjam M.; Vermeulen, R. Jeroen

    2010-01-01

    Aim: To investigate the predictive value of motor testing at 1 year for motor and mental outcome at 2 years after perinatal hypoxic-ischaemic encephalopathy (HIE) in term neonates. Method: Motor and mental outcome at 2 years was assessed with the Bayley Scales of Infant Development, 2nd edition (BSID-II) in 32 surviving children (20 males, 12…

  15. Analysis of Urban Forest Needs as Anthropogenic (CO2) Gas Absorbent in Semarang City

    Science.gov (United States)

    Febriani, Anisa Putri; Retnaningsih Soeprobowati, Tri; Maryono

    2018-02-01

    Green open space in cities in significant needs to maintenance environment quality. On of the critical function is to absorb increasing number of gas CO2. Therefore, developing urban forest in cities is very importance. The objective of the study is to determine the area of urban forest as CO2 gas anthropogenic absorb which is formed from fuel, diesel fuel, liquid petroleum gas. The study consists of (1) Analyzing the number of CO2 gas emission by calculating the needs of petroleum and gas based on the number of population, (2) Analyzing the power of gas absorption, (3) Measuring the air concentration of CO2 gas ambient based on daily traffic activities. This study shown that from year 2013 to year 2017, the increasing of urban forest is not so significant. For year 2013 the green open space in Semarang City are 373.67 hectares (7.5 percent from Semarang City area), consists of 239 parks, 11 public cemeteries, production forests, community forests, and urban forests, however the area of urban forest is not increase. The study assess that Antidesmabunius is one of the green species which high absorb capacity planted for Semarang. This trees produce 31,31 ton annually. This study proposed to fostering Antidesmabunius as one principle threes in Semarang urban forest.

  16. Outcomes of Revision Hip Arthroscopy: 2-Year Clinical Follow-up.

    Science.gov (United States)

    Gupta, Asheesh; Redmond, John M; Stake, Christine E; Dunne, Kevin F; Hammarstedt, Jon E; Domb, Benjamin G

    2016-05-01

    To evaluate clinical outcomes, pain, and patient satisfaction following revision hip arthroscopy with a minimum 2-year follow-up. From April 2008 to October 2011, data were prospectively collected on all patients undergoing revision hip arthroscopy. All patients were assessed pre- and postoperatively with 4 patient-reported outcome (PRO) measures: the modified Harris hip score (mHHS), nonarthritic hip score (NAHS), hip outcome score-activities of daily living (HOS-ADL), and hip outcome score-sport-specific subscales (HOS-SSS). Pain was estimated on the visual analog scale (VAS). Patient satisfaction was measured on a scale from 0 to 10. The number of patients who underwent subsequent revision arthroscopy or total hip arthroplasty during the study period is also reported. Eighty-seven patients underwent revision hip arthroscopy during the study period. Seventy (80.5%) patients were included in our study. Average follow-up time was 28 months (range, 20 to 47.4 months). In terms of residual femoroacetabular impingement morphology, 45.7% of patients had preoperative alpha angles ≥ 55°, and 7.14% of patients had a lateral center-edge angle ≥ 40°. The score improvement from preoperative to 2-year follow-up was 57.84 to 73.65 for mHHS, 62.79 to 83.04 for HOS-ADL, 37.33 to 54.93 for HOS-SSS, and 55.65 to 70.79 for NAHS. VAS decreased from 6.72 to 4.08. All scores demonstrated statistically significant improvement (P arthroscopy during the study period. We found an overall minor complication rate of 10%. Revision hip arthroscopy for all procedures performed on aggregate has improved clinical outcomes for all PROs, high survivorship, and high patient satisfaction scores at short-term follow-up. Patients should be counseled regarding the potential progression of degenerative change leading to arthroplasty and the potential for revision surgery. Level IV retrospective case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc

  17. Neonatal Glycemia and Neurodevelopmental Outcomes at 2 Years.

    Science.gov (United States)

    McKinlay, Christopher J D; Alsweiler, Jane M; Ansell, Judith M; Anstice, Nicola S; Chase, J Geoffrey; Gamble, Gregory D; Harris, Deborah L; Jacobs, Robert J; Jiang, Yannan; Paudel, Nabin; Signal, Matthew; Thompson, Benjamin; Wouldes, Trecia A; Yu, Tzu-Ying; Harding, Jane E

    2015-10-15

    Neonatal hypoglycemia is common and can cause neurologic impairment, but evidence supporting thresholds for intervention is limited. We performed a prospective cohort study involving 528 neonates with a gestational age of at least 35 weeks who were considered to be at risk for hypoglycemia; all were treated to maintain a blood glucose concentration of at least 47 mg per deciliter (2.6 mmol per liter). We intermittently measured blood glucose for up to 7 days. We continuously monitored interstitial glucose concentrations, which were masked to clinical staff. Assessment at 2 years included Bayley Scales of Infant Development III and tests of executive and visual function. Of 614 children, 528 were eligible, and 404 (77% of eligible children) were assessed; 216 children (53%) had neonatal hypoglycemia (blood glucose concentration, Hypoglycemia, when treated to maintain a blood glucose concentration of at least 47 mg per deciliter, was not associated with an increased risk of the primary outcomes of neurosensory impairment (risk ratio, 0.95; 95% confidence interval [CI], 0.75 to 1.20; P=0.67) and processing difficulty, defined as an executive-function score or motion coherence threshold that was more than 1.5 SD from the mean (risk ratio, 0.92; 95% CI, 0.56 to 1.51; P=0.74). Risks were not increased among children with unrecognized hypoglycemia (a low interstitial glucose concentration only). The lowest blood glucose concentration, number of hypoglycemic episodes and events, and negative interstitial increment (area above the interstitial glucose concentration curve and below 47 mg per deciliter) also did not predict the outcome. In this cohort, neonatal hypoglycemia was not associated with an adverse neurologic outcome when treatment was provided to maintain a blood glucose concentration of at least 47 mg per deciliter. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others.).

  18. Absorber Model for CO2 Capture by Monoethanolamine

    DEFF Research Database (Denmark)

    Faramarzi, Leila; Kontogeorgis, Georgios; Michelsen, Michael Locht

    2010-01-01

    The rate-based steady-state model proposed by Gabrielsen et al. (Gabrielsen, J.; Michelsen, M. L.; Kontogeorgis, G. M.; Stenby, E. H. AIChE J. 2006, 52, 10, 3443-3451) for the design of the CO2-2-amino-2-methylpropanol absorbers is adopted and improved for the design of the CO2-monoethanolamine......, and their impact on the model's prediction is compared. The model has been successfully applied to CO2 absorber packed columns and validated against pilot plant data with good agreement....

  19. The MuCool/MICE LH2 Absorber Program

    International Nuclear Information System (INIS)

    Cummings, Mary Anne

    2004-01-01

    Hydrogen absorber R and D for the MuCool Collaboration is actively pushing ahead on two parallel and complementary fronts. The continuing LH2 engineering and technical developments by the MuCool group, conducted by ICAR institutions (NIU, IIT and UIUC), the University of Mississippi and Oxford University in cooperation with Fermilab, are summarized here, including plans for the first tests of an absorber prototype from Osaka University and KEK cooled by internal convection at the newly constructed FNAL MuCool Test Area (MTA). Designs for the high-power test of another absorber prototype (employing external heat exchange) are complete and the system will be installed by summer 2004. A convection-cooled absorber design is being developed for the approved MICE cooling demonstration at Rutherford Appleton Laboratory

  20. Convection-type LH2 absorber R and D for muon ionization cooling

    International Nuclear Information System (INIS)

    Ishimoto, S.; Bandura, L.; Black, E.L.; Boghosian, M.; Cassel, K.W.; Cummings, M.A.; Darve, C.; Dyshkant, A.; Errede, D.; Geer, S.; Haney, M.; Hedin, D.; Johnson, R.; Johnstone, C.J.; Kaplan, D.M.; Kubik, D.; Kuno, Y.; Majewski, S.; Popovic, M.; Reep, M.; Summers, D.; Suzuki, S.; Yoshimura, K.

    2003-01-01

    A feasibility study on liquid hydrogen (LH 2 ) absorbers for muon ionization cooling is reported. In muon ionization cooling, an LH 2 absorber is required to have a high cooling power greater than 100 W to cool heat deposited by muons passing through. That heat in LH 2 can be removed at either external or internal heat exchangers, which are cooled by cold helium gas. As one of the internal heat exchanger types, a convection-type absorber is proposed. In the convection-type absorber, heat is taken away by the convection of LH 2 in the absorber. The heat exchanger efficiency for the convection-type absorber is calculated. A possible design is presented

  1. [Fully absorbable drug eluting coronary stent: where do we stand in 2014?].

    Science.gov (United States)

    Kočka, Viktor; Toušek, Petr; Lisa, Libor; Buděšínský, Tomáš

    2014-04-01

    Coronary stent is routinely used in majority percutaneous coronary interventions for a long time. They have an important role, especially, in the first months after intervention. We can consider as a breakthrough point the development of stent which has ability to absorb in intervened artery after a few years. The review presents current techniques of fully absorbable coronary stents and also provides clinical trials and experiences available in 2014. The article continues with discussion between supporters and opponents of this new technique, but definitive conclusion can't be done yet. The authors conclude the review with their own opinion. There are many encouraging data in patients with good clinical outcome after implantation of absorbable stents in more than 10 years follow-up.

  2. Children who screen positive for autism at 2.5 years and receive early intervention: a prospective naturalistic 2-year outcome study

    Science.gov (United States)

    Spjut Jansson, Birgitta; Miniscalco, Carmela; Westerlund, Joakim; Kantzer, Anne-Katrin; Fernell, Elisabeth; Gillberg, Christopher

    2016-01-01

    Background Previous research has stressed the importance of early identification and intervention for children with autism spectrum disorders. Methods Children who had screened positive for autism at the age of 2.5 years in a general population screening and then received a diagnosis of autism spectrum disorder were enrolled in an intervention program provided by Swedish habilitation services. The following interventions were available: a comprehensive intervention based on Applied Behavior Analysis – Intensive Learning (IL) – in two settings, which included home- and preschool-based (IL Regular) and only home-based (IL Modified) and eclectic interventions. Results There was considerable variability in terms of outcome, but intervention group status was not associated with any of the chosen outcome variables. Conclusion The main finding was that the type of intervention was not critical for outcome of adaptive or global functioning. The variability in outcome demonstrates the need for continuous assessments and evaluation of the child’s function and behavior throughout the intervention period. PMID:27621636

  3. Convection-type LH{sub 2} absorber R and D for muon ionization cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ishimoto, S. E-mail: shigeru.ishimoto@kek.jp; Bandura, L.; Black, E.L.; Boghosian, M.; Cassel, K.W.; Cummings, M.A.; Darve, C.; Dyshkant, A.; Errede, D.; Geer, S.; Haney, M.; Hedin, D.; Johnson, R.; Johnstone, C.J.; Kaplan, D.M.; Kubik, D.; Kuno, Y.; Majewski, S.; Popovic, M.; Reep, M.; Summers, D.; Suzuki, S.; Yoshimura, K

    2003-05-01

    A feasibility study on liquid hydrogen (LH{sub 2}) absorbers for muon ionization cooling is reported. In muon ionization cooling, an LH{sub 2} absorber is required to have a high cooling power greater than 100 W to cool heat deposited by muons passing through. That heat in LH{sub 2} can be removed at either external or internal heat exchangers, which are cooled by cold helium gas. As one of the internal heat exchanger types, a convection-type absorber is proposed. In the convection-type absorber, heat is taken away by the convection of LH{sub 2} in the absorber. The heat exchanger efficiency for the convection-type absorber is calculated. A possible design is presented.

  4. Leg pain and psychological variables predict outcome 2-3 years after lumbar fusion surgery.

    Science.gov (United States)

    Abbott, Allan D; Tyni-Lenné, Raija; Hedlund, Rune

    2011-10-01

    Prediction studies testing a thorough range of psychological variables in addition to demographic, work-related and clinical variables are lacking in lumbar fusion surgery research. This prospective cohort study aimed at examining predictions of functional disability, back pain and health-related quality of life (HRQOL) 2-3 years after lumbar fusion by regressing nonlinear relations in a multivariate predictive model of pre-surgical variables. Before and 2-3 years after lumbar fusion surgery, patients completed measures investigating demographics, work-related variables, clinical variables, functional self-efficacy, outcome expectancy, fear of movement/(re)injury, mental health and pain coping. Categorical regression with optimal scaling transformation, elastic net regularization and bootstrapping were used to investigate predictor variables and address predictive model validity. The most parsimonious and stable subset of pre-surgical predictor variables explained 41.6, 36.0 and 25.6% of the variance in functional disability, back pain intensity and HRQOL 2-3 years after lumbar fusion. Pre-surgical control over pain significantly predicted functional disability and HRQOL. Pre-surgical catastrophizing and leg pain intensity significantly predicted functional disability and back pain while the pre-surgical straight leg raise significantly predicted back pain. Post-operative psychomotor therapy also significantly predicted functional disability while pre-surgical outcome expectations significantly predicted HRQOL. For the median dichotomised classification of functional disability, back pain intensity and HRQOL levels 2-3 years post-surgery, the discriminative ability of the prediction models was of good quality. The results demonstrate the importance of pre-surgical psychological factors, leg pain intensity, straight leg raise and post-operative psychomotor therapy in the predictions of functional disability, back pain and HRQOL-related outcomes.

  5. Physical Therapy Protocol After Hip Arthroscopy: Clinical Guidelines Supported by 2-Year Outcomes.

    Science.gov (United States)

    Domb, Benjamin G; Sgroi, Terrance A; VanDevender, Jeremy C

    2016-07-01

    Femoroacetabular impingement (FAI) was first described by Ganz in 2003 and is a significant cause of decreased function and mobility. Femoroacetabular impingement must be treated in an individualized, goal-oriented, stepwise fashion. This protocol was developed with biomechanical considerations of soft tissue and bony structures surrounding the hip joint. The PubMed database was searched for scientific and review articles from the years 2000 to 2015 utilizing the search terms: hip rehabilitation, femoroacetabular impingement, and arthroscopy. Clinical review. Level 5. Five hundred ninety-five of 738 patients were available for follow-up showing improvement from preoperative to 2-year follow-up of 61.29 to 82.02 for modified Harris Hip Score (mHHS), 62.79 to 83.04 for Hip Outcome Score-Activities of Daily Living (HOS-ADL), 40.96 to 70.07 for Hip Outcome Score-Sport-Specific Subscale (HOS-SSS), and 57.97 to 80.41 for Non-Arthritic Hip Score (NAHS); visual analog scale (VAS) scores decreased from 5.86 preoperatively to 2.94 postoperatively. Following a structured, criteria-based program, appropriate patients undergoing hip arthroscopy may achieve excellent outcomes and return to full independent activities of daily living as well as sport. © 2016 The Author(s).

  6. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, A Ram; Ahn, Sung Min [Dept. of Radiological Science, The Graduate School, Gachon University, Incheon (Korea, Republic of); Lee, In Ja [Dept. of Radiologic technology, Dongnam health University, Suwon (Korea, Republic of)

    2017-09-15

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

  7. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    International Nuclear Information System (INIS)

    Kang, A Ram; Ahn, Sung Min; Lee, In Ja

    2017-01-01

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied

  8. Absorbable Polydioxanone (PDS) suture provides fewer wound complications than polyester (ethibond) suture in acute Tendo-Achilles rupture repair

    LENUS (Irish Health Repository)

    Baig, M N

    2017-05-01

    We prospectively studied acute Achilles tendon rupture in patients over a two 2-year period and reviewed the causes, outcome and complications. There were 53 patients included with acute Achilles rupture with minimum follow up period of 6 months. We compared the outcomes including infection rate and Boyden score between the two groups repaired by Polydioxanone and Polyester respectively. All infected cases had a suture repair using the polyester suture. The difference in the infection rate was highly significant between the 2 groups (p=0.001). All 34 patients (100%) in the PDS group had good \\/ excellent results based on the Boyden clinical assessment. Conversely, only 16 patients 9(68.4%) had good or excellent results IN Polyester repair group. Patients treated with a non- absorbable suture (ethibond) material for repair had a higher incidence infection and worse Boyden scores than the absorbable PDS group.

  9. Twelve-year course and outcome predictors of anorexia nervosa.

    Science.gov (United States)

    Fichter, Manfred M; Quadflieg, Norbert; Hedlund, Susanne

    2006-03-01

    The current study presents the long-term course of anorexia nervosa (AN) over 12 years in a large sample of 103 patients diagnosed according to criteria in the 4th ed. of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV). Assessments were made at the beginning of therapy, at the end of therapy, at the 2-year follow-up, at the 6-year follow-up, and at the 12-year follow-up. Self-rating and an expert-rating interview data were obtained. The participation rate at the 12-year follow-up was 88% of those alive. There was substantial improvement during therapy, a moderate (in many instances nonsignificant) decline during the first 2 years posttreatment, and further improvement from 3 to 12 years posttreatment. Based on a global 12-year outcome score, 27.5% had a good outcome, 25.3% an intermediate outcome, 39.6% had a poor outcome, and 7 (7.7%) were deceased. At the 12-year follow-up 19.0% had AN, 9.5% had bulimia nervosa-purging type (BN-P), 19.0% were classified as eating disorder not otherwise specified (EDNOS). A total of 52.4% showed no major DSM-IV eating disorder and 0% had binge eating disorder (BED). Systematic-strictly empirically based-model building resulted in a parsimonious model including four predictors of unfavorable 12-year outcome explaining 45% of the variance, that is, sexual problems, impulsivity, long duration of inpatient treatment, and long duration of an eating disorder. Mortality was high and symptomatic recovery protracted. Impulsivity, symptom severity, and chronicity were the important factors for predicting the 12-year outcome.

  10. Esthetic outcome and alterations of soft tissue around single implant crowns: a 2-year prospective study.

    Science.gov (United States)

    Gu, Ying-Xin; Shi, Jun-Yu; Zhuang, Long-Fei; Qiao, Shi-Chong; Xu, You-You; Lai, Hong-Chang

    2015-08-01

    The aim of this prospective study was to assess the esthetic outcome and alterations of peri-implant soft tissue using tissue-level implants. Furthermore, the influencing factors, including grafting and gingival biotype, of esthetic outcome of peri-implant soft tissue were also evaluated. Of 38 patients with single missing anterior tooth in maxilla were treated with a Straumann (®) Standard Plus SLA implant. Bone augmentation was performed in 24 patients. Follow-up was conducted at 12 and 24 months after definitive crowns placement. Esthetic outcome using the pink esthetic score/white esthetic score (PES/WES) and clinical parameters were evaluated. The mean PES/WES value at baseline, 1-year, and 2-year examination was 13.79, 14.87, and 14.96. Significant improvement was found between baseline and 1-year examination (P esthetic area. Favorable short-term esthetic outcome and stability of soft tissue around single implant crowns can be expected in patients with or without graft. However, graft procedures might have an unfavorable effect on the esthetic outcome. Gingival biotype can be considered as prognostic factor for esthetic outcome. RCTs with long-term follow-up are needed to provide evidence for the long-term stability of peri-implant soft tissue using tissue-level implant systems. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The Anglo-Scandinavian Cardiac Outcomes Trial lipid lowering arm: extended observations 2 years after trial closure

    DEFF Research Database (Denmark)

    Sever, Peter S; Poulter, Neil R; Dahlof, Bjorn

    2008-01-01

    Aims To determine the cardiovascular benefits in those originally assigned atorvastatin in the Anglo-Scandinavian Cardiac Outcomes Trial-2.2 years after closure of the lipid-lowering arm of the trial (ASCOT-LLA). Methods and results The Blood Pressure Lowering Arm of the ASCOT trial (ASCOT......-BPLA) compared two different antihypertensive treatment strategies on cardiovascular outcomes. ASCOT-LLA was a double-blind placebo-controlled trial of atorvastatin in those enrolled into ASCOT-BPLA with total cholesterol concentrations at baseline of ... enrolled in ASCOT-BPLA and 10 305 were further assigned either atorvastatin, 10 mg, or placebo. ASCOT-LLA was stopped prematurely after a median 3.3 years follow-up because of substantial cardiovascular benefits in those assigned atorvastatin. Trial physicians were invited to offer atorvastatin to all...

  12. Method of absorbing UF6 from gaseous mixtures in alkamine absorbents

    International Nuclear Information System (INIS)

    Lafferty, R.H.; Smiley, S.H.; Radimer, K.J.

    1976-01-01

    A method is described for recovering UF 6 from gaseous mixtures by absorption in a liquid. The liquid absorbent must have a relatively low viscosity and at least one component of the absorbent is an alkamine having less than 3 carbon atoms bonded to the amino nitrogen, less than 2 of the carbon atoms other than those bonded to the amino nitrogen are free of the hydroxy radical and precipitate the absorbed uranium from the absorbent. At least one component of the absorbent is chosen from the group consisting of ethanolamine, diethanolamine, and 3-methyl-3-amino-propane-diol-1,2

  13. Children who screen positive for autism at 2.5 years and receive early intervention: a prospective naturalistic 2-year outcome study

    Directory of Open Access Journals (Sweden)

    Spjut Jansson B

    2016-09-01

    Full Text Available Birgitta Spjut Jansson,1–3 Carmela Miniscalco,1,4 Joakim Westerlund,1,5 Anne-Katrin Kantzer,1,6 Elisabeth Fernell,1 Christopher Gillberg1 1Gillberg Neuropsychiatry Centre, Sahlgrenska Academy, Institute of Neuroscience and Physiology, University of Gothenburg, 2Unit of Child and Adolescent Habilitation, 3Department of Psychology, University of Gothenburg, 4Division of Speech and Language Pathology, Institute of Neuroscience and Physiology, University of Gothenburg, Gothenburg, 5Department of Psychology, University of Stockholm, Stockholm, 6Department of Child and Adolescent Psychiatry, NU Hospital Organization, Trollhättan, Sweden Background: Previous research has stressed the importance of early identification and intervention for children with autism spectrum disorders. Methods: Children who had screened positive for autism at the age of 2.5 years in a general population screening and then received a diagnosis of autism spectrum disorder were enrolled in an intervention program provided by Swedish habilitation services. The following interventions were available: a comprehensive intervention based on Applied Behavior Analysis – Intensive Learning (IL – in two settings, which included home- and preschool-based (IL Regular and only home-based (IL Modified and eclectic interventions.Results: There was considerable variability in terms of outcome, but intervention group status was not associated with any of the chosen outcome variables. Conclusion: The main finding was that the type of intervention was not critical for outcome of adaptive or global functioning. The variability in outcome demonstrates the need for continuous assessments and evaluation of the child’s function and behavior throughout the intervention period. Keywords: autism spectrum disorder, preschool children, early intervention, ABA, cognitive function, follow-up

  14. Does Extended Preoperative Rehabilitation Influence Outcomes 2 Years After ACL Reconstruction? A Comparative Effectiveness Study Between the MOON and Delaware-Oslo ACL Cohorts.

    Science.gov (United States)

    Failla, Mathew J; Logerstedt, David S; Grindem, Hege; Axe, Michael J; Risberg, May Arna; Engebretsen, Lars; Huston, Laura J; Spindler, Kurt P; Snyder-Mackler, Lynn

    2016-10-01

    Rehabilitation before anterior cruciate ligament (ACL) reconstruction (ACLR) is effective at improving postoperative outcomes at least in the short term. Less is known about the effects of preoperative rehabilitation on functional outcomes and return-to-sport (RTS) rates 2 years after reconstruction. The purpose of this study was to compare functional outcomes 2 years after ACLR in a cohort that underwent additional preoperative rehabilitation, including progressive strengthening and neuromuscular training after impairments were resolved, compared with a nonexperimental cohort. We hypothesized that the cohort treated with extended preoperative rehabilitation would have superior functional outcomes 2 years after ACLR. Cohort study; Level of evidence, 3. This study compared outcomes after an ACL rupture in an international cohort (Delaware-Oslo ACL Cohort [DOC]) treated with extended preoperative rehabilitation, including neuromuscular training, to data from the Multicenter Orthopaedic Outcomes Network (MOON) cohort, which did not undergo extended preoperative rehabilitation. Inclusion and exclusion criteria from the DOC were applied to the MOON database to extract a homogeneous sample for comparison. Patients achieved knee impairment resolution before ACLR, and postoperative rehabilitation followed each cohort's respective criterion-based protocol. Patients completed the International Knee Documentation Committee (IKDC) subjective knee form and Knee injury and Osteoarthritis Outcome Score (KOOS) at enrollment and again 2 years after ACLR. RTS rates were calculated for each cohort at 2 years. After adjusting for baseline IKDC and KOOS scores, the DOC patients showed significant and clinically meaningful differences in IKDC and KOOS scores 2 years after ACLR. There was a significantly higher (P < .001) percentage of DOC patients returning to preinjury sports (72%) compared with those in the MOON cohort (63%). The cohort treated with additional preoperative

  15. Capability of Several Plant Species in Absorbing Gas Pollutant (NO2)

    International Nuclear Information System (INIS)

    Astra Dwi Patra; Nizar Nasrullah; EIsje L Sisworo

    2004-01-01

    Increasing pollutant from vehicles, especially NO 2 , could cause environmental quality degradation. NO 2 is disastrous for human health due to its capability to trigger long diseases. Due to this, it is important to reduce this pollutant, which could be done among others by plants. The objectives of this experiment was to find plants which have the highest capacity to absorb NO 2 and factors affecting this such as, stomata density, chlorophyll, leave thickness, leave specific density, light and dark condition. The plants exposure to NO 2 used 15 N - labelled NO 2 ( 15 NO 2 ). Twelve plant species were exposed to 15 NO 2 at a rate of 3 ppm in a gas chamber for 60 minutes. The environmental conditions in the chamber were controlled at 30 o C, 1000 lux light intensity, and 60% initial relative humidity. The total nitrogen of each plant part was analysed using the Kjeldahl method, while the 15 N content of these parts was done by emission spectrometer (YASCO - N 151). The results of this experiment showed that all the plants used in this experiment has the capacity in absorbing the pollutant gas at dark as well as light conditions. The evident showed that stomata density, leave thickness, and leave specific density affect the absorbing capacity of the pollutant gas. The higher the stomata density, the thinner the leaves, and the lower the leave specific density, the higher the capacity of plants to absorb NO 2 . It is recommended to use these 12 plants as an element of roadside green belt in towns. (author)

  16. Quality of Recovery, Postdischarge Hospital Utilization, and 2-Year Functional Outcomes After an Outpatient Total Knee Arthroplasty Program.

    Science.gov (United States)

    Gauthier-Kwan, Olivier Y; Dobransky, Johanna S; Dervin, Geoffrey F

    2018-02-05

    Outpatient total knee arthroplasty (TKA) has been made possible with advances in perioperative care and standardized clinical inpatient pathways. While many studies report on benefits of outpatient programs, none explore patient-reported outcome measures. As such, our goals were to compare the short-term quality of recovery; highlight postdischarge hospital resources utilization; and report on 2-year functional outcomes scores. This was a prospective comparative cohort study of 43 inpatients (43 TKAs) and 43 outpatients (43 TKAs) operated on by a single surgeon between September 28, 2010 and May 5, 2015. All patients were given a diary to complete at 1, 3, 7, 14, and 28 days postoperatively; we collected 90-day complications, readmissions, and emergency department visits; Knee Injury and Osteoarthritis Outcome Score and Western Ontario and McMaster Universities Osteoarthritis Index scores were completed preoperatively and 2 years postoperatively. SPSS (IBM, version 22.0) was used for all statistical analyses. Quality of recovery (QoR-9) was similar in the outpatient TKA group compared with the inpatient group. No statistically significant differences were observed for Knee Injury and Osteoarthritis Outcome Score and Western Ontario and McMaster Universities Osteoarthritis Index subscores (P > .05). There was 1 readmission in both outpatient and inpatient groups. Six inpatients and 8 outpatients returned to the emergency department for any reason within 90 days, with no statistical significance observed between the 2 groups (P = .771). Outpatient TKA in selected patients produced similar short-term and 2-year patient-reported outcome measures and a comparable 90-day postdischarge hospital resource utilization when compared to an inpatient cohort, supporting further investigation into outpatient TKA. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Arthroscopic Partial Repair of Irreparable Rotator Cuff Tears: Preoperative Factors Associated With Outcome Deterioration Over 2 Years.

    Science.gov (United States)

    Shon, Min Soo; Koh, Kyoung Hwan; Lim, Tae Kang; Kim, Won Ju; Kim, Kyung Cheon; Yoo, Jae Chul

    2015-08-01

    Arthroscopic partial repair is a treatment option in irreparable large-to-massive rotator cuff tears without arthritic changes. However, there are indications that arthroscopic partial repair does not yield satisfactory outcomes. To report the clinical and radiographic results of arthroscopic partial repairs in patients with irreparable large-to-massive cuff tears. In addition, an analysis was performed regarding preoperative factors that may influence patient outcomes and patient-rated satisfaction over time. Case series; Level of evidence, 4. From 2005 to 2011, a total of 31 patients who underwent arthroscopic partial repair for irreparable large-to-massive cuff tears were retrospectively evaluated. Partial repair was defined as posterior cuff tissue repair with or without subscapularis tendon repair to restore the transverse force couple of the cuff. Pain visual analog scale (PVAS), questionnaire results (American Shoulder and Elbow Surgeons [ASES] and Simple Shoulder Test [SST]), and radiographic changes (acromiohumeral distance and degenerative change) were assessed preoperatively, at first follow-up (roughly 1 year postoperatively), and at final follow-up (>2 years postoperatively). Patients rated their satisfaction level at each postoperative follow-up as well. Preoperative factors that might influence outcomes, such as patient demographics, tear size, and fatty infiltration, were investigated. The preoperative, first follow-up, and final follow-up results for mean PVAS (5.13, 2.13, and 3.16, respectively) and questionnaires (ASES: 41.97, 76.37, and 73.78; SST: 3.61, 6.33, and 6.07, respectively) improved significantly (all P .05) from the first to the final follow-up. Among preoperative factors, fatty infiltration of the teres minor was identified as the only statistically significant factor affecting patient-rated satisfaction (P = .007). This study showed that arthroscopic partial repair may produce initial improvement in selected outcomes at 2-year

  18. Cyclops lesions detected by MRI are frequent findings after ACL surgical reconstruction but do not impact clinical outcome over 2 years

    Energy Technology Data Exchange (ETDEWEB)

    Facchetti, Luca [University of California, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); University of Brescia, Department of Radiology, Brescia (Italy); Schwaiger, Benedikt J.; Gersing, Alexandra S.; Nardo, Lorenzo; Majumdar, Sharmila; Link, Thomas M.; Li, Xiaojuan [University of California, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Guimaraes, Julio Brandao [University of California, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Federal University of Sao Paulo (UNIFESP), Department of Radiology, Sao Paulo (Brazil); Ma, Benjamin C. [University of California, Department of Orthopedic Surgery, San Francisco, CA (United States); Collaboration: UCSF-P50-ACL Consortium; AF-ACL Consortium

    2017-08-15

    To assess the impact of cyclops lesions with MRI in patients treated for anterior cruciate ligament (ACL) tears on clinical outcome. In 113 patients (age 29.8 ± 10.5y; 55 females; BMI 24.8 ± 3.7 kg/m{sup 2}) with complete ACL tear, 3 T-MRI scans were obtained before, 6-months, 1-year (n = 75) and 2-years (n = 33) after ACL reconstruction. Presence and volume of cyclops lesions were assessed. Clinical outcomes were measured using the Knee injury and Osteoarthritis Outcome Score (KOOS) and differences between time points (∇KOOS) were calculated. Changes of KOOS subscales were compared between patients with and without cyclops lesion. KOOS was also correlated with lesion volume. Cyclops lesions were found in 25% (28/113), 27% (20/75) and 33% (11/33) of patients after 6-months, 1- and 2-years, respectively. The lesion volume did not change significantly (P > 0.05) between time points, measuring 0.65 ± 0.59, 0.81 ± 0.70 and 0.72.9 ± 0.96 cm{sup 3}, respectively. Clinical outcomes based on KOOS subscales were not significantly different in patients with cyclops lesions compared to those without cyclops lesions (each comparison P > 0.05), and no significant associations of clinical outcomes with lesion volume were found (P > 0.05). Neither presence nor size of cyclops lesions within the first 2-years after ACL surgery were associated with inferior clinical outcome. (orig.)

  19. Depressive symptoms, satisfaction with health care, and 2-year work outcomes in an employed population.

    Science.gov (United States)

    Druss, B G; Schlesinger, M; Allen, H M

    2001-05-01

    The relationship of depressive symptoms, satisfaction with health care, and 2-year work outcomes was examined in a national cohort of employees. A total of 6,239 employees of three corporations completed surveys on health and satisfaction with health care in 1993 and 1995. This study used bivariate and multivariate analyses to examine the relationships of depressive symptoms (a score below 43 on the Medical Outcomes Study Short-Form Health Survey mental component summary), satisfaction with a variety of dimensions of health care in 1993, and work outcomes (sick days and decreased effectiveness in the workplace) in 1995. The odds of missed work due to health problems in 1995 were twice as high for employees with depressive symptoms in both 1993 and 1995 as for those without depressive symptoms in either year. The odds of decreased effectiveness at work in 1995 was seven times as high. Among individuals with depressive symptoms in 1993, a report of one or more problems with clinical care in 1993 predicted a 34% increase in the odds of persistent depressive symptoms and a 66% increased odds of decreased effectiveness at work in 1995. There was a weaker association between problems with plan administration and outcomes. Depressive disorders in the workplace persist over time and have a major effect on work performance, most notably on "presenteeism," or reduced effectiveness in the workplace. The study's findings suggest a potentially important link between consumers' perceptions of clinical care and work outcomes in this population.

  20. Differential impact of five coronary devices on plaque size: insights from the ABSORB and SPIRIT trials.

    Science.gov (United States)

    García-García, Héctor M; Serruys, Patrick W; Campos, Carlos M; Onuma, Yoshinobu

    2014-08-20

    Coronary plaque size modification, by either local (device) or systemic treatments, has been the target for many years. From ABSORB Cohort A (Absorb BVS 1.0), ABSORB Cohort B (Absorb BVS 1.1), SPIRIT FIRST (Multi-Link Vision vs. Xience V) & SPIRIT II (Xience V vs. Taxus), we calculated the total plaque area (vessel minus lumen area - thus it comprises both compartments - the plaque behind struts and the neointima.) changes by IVUS. A total of 313 patients were included. Comparison-at-6-month follow-up: All devices induced an increase in the total plaque area. The largest increase occurred with Vision and Taxus stents as compared to other devices [Absorb BVS (1.0 and 1.1) and Xience V], (p=0.0002). Comparison-at-2-year follow-up: Absorb BVS 1.1 had a larger increase from post procedure in total plaque compared to Absorb BVS 1.0, Xience V and Taxus (p=0.0499). However, in Absorb BVS 1.1 total plaque showed a reduction of 2.2% from 1 to 3 years. Specifically, the total plaque in the sequential cohorts of Absorb BVS 1.1 increased 16.2% from baseline to 2 years (Cohort B1) while at 3 years this increase is only 5% compared to baseline (Cohort B2). Local devices affect coronary plaque size differently and it depends on the platform (metallic vs. polymeric) and on whether it is a bare - or drug eluting stent. Coronary scaffolds appear to be a promising alternative to metallic stents since they allow plaque regression at long-term follow-up. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. A prospective 2-year examination of cognitive and behavioral correlates of provoked vestibulodynia outcomes.

    Science.gov (United States)

    Davis, Seth N P; Bergeron, Sophie; Bois, Katy; Sadikaj, Gentiana; Binik, Yitzchak M; Steben, Marc

    2015-04-01

    Provoked vestibulodynia (PVD) is a common genital pain disorder in women that is associated with sexual dysfunction and lowered sexual satisfaction. A potentially applicable cognitive-behavioral model of chronic pain and disability is the fear-avoidance model (FAM) of pain. The FAM posits that cognitive variables, such as pain catastrophizing, fear, and anxiety lead to avoidance of pain-provoking behaviors (eg, intercourse), resulting in continued pain and disability. Although some of the FAM variables have been shown to be associated with PVD pain and sexuality outcomes, the model as a whole has never been tested in this population. An additional protective factor, pain self-efficacy (SE), is also associated with PVD, but has not been tested within the FAM model. Using a 2-year longitudinal design, we examine (1) whether initial levels (T1) of the independent FAM variables and pain SE were associated with changes in pain, sexual function, and sexual satisfaction over the 2-year time period; (2) the prospective contribution of changes in cognitive-affective (FAM) variables to changes in pain, and sexuality outcomes; and (3) whether these were mediated by behavioral change (avoidance of intercourse). A sample of 222 women with PVD completed self-report measures of FAM variables, SE, pain, sexual function, and sexual satisfaction at time 1 and at a 2-year follow-up. Structural equation modeling with Latent Difference Scores was used to examine changes and to examine mediation between variables. Questionnaires included the Pain Catastrophizing Scale, McGill Pain Questionnaire, Trait Anxiety Inventory, Pain Self-Efficacy Scale, and Global Measure of Sexual Satisfaction, Female Sexual Function Index. Participants who reported higher SE at T1 reported greater declines in pain, greater increases in sexual satisfaction, and greater declines in sexual function over the 2 time points. The overall change model did not support the FAM using negative cognitive

  2. Combinatorial development of Cu2SnS3 as an earth abundant photovoltaic absorber

    Science.gov (United States)

    Baranowski, Lauryn L.

    The development of high efficiency, earth abundant photovoltaic absorbers is critical if photovoltaics are to be implemented on the TW scale. Although traditional thin films absorbers such as Cu(In,Ga)Se2 and CdTe have achieved over 20% device efficiencies, the ultimately scalability of these devices may be limited by elemental scarcity and toxicity issues. To date, the most successful earth abundant thin film absorber is Cu2ZnSn(S,Se) 4, which has achieved 12.6% efficiency as of 2014. However, chemical complexity and disorder issues with this material have made the path to higher efficiency CZTSSe devices unclear. As a result, many researchers are now exploring alternative earth abundant absorber materials. In this thesis, we apply our "rapid development" methodology to the exploration of alternative photovoltaic absorbers. The rapid development (RD) methodology, consisting of exploration, research, and development stages, uses complementary theory and experiment to assess candidate materials and down-select in each stage. The overall result is that, in the time span of ~2-3 years, we are able to rapidly go from tens of possible absorber materials to 1-2 working PV device prototypes. Here, we demonstrate the RD approach as applied to the Cu-Sn-S system. We begin our investigation of the Cu-Sn-S system by evaluating the thermodynamic stability, electrical transport, electronic structure, and optical and defect properties of candidate materials using complementary theory and experiment. We find that Cu2SnS3 is the most promising absorber candidate because of its strong optical absorption, tunable doping, and wide stability range. Our other candidate compounds suffer from serious flaws that preclude them from being successful photovoltaic absorbers, including too high experimental conductivity (Cu4SnS4), or poor hole transport and low absorption coefficient (Cu4Sn7S16). Next, we investigate the doping and defect physics of Cu2SnS 3. We identify the origins of the

  3. A study on the nuclear characteristics of enriched gadolinia burnable absorber rods; the first year (2000) report

    International Nuclear Information System (INIS)

    Zee, Sung Quun; Lee, C.C.; Song, J. S.; Cho, B. O.; Joo, H. G.; Park, S. Y.; Kim, H. Y.; Cho, J. Y.; Kim, K. S.

    2001-04-01

    An analysis model using MICBURN-3/CASMO-3 is established for the enriched gadolinia burnable absorber rods. A homogenized cross section editing code, PROLOG, is modified so that it can handle such a fuel assembly that includes two different types of gadolinia rods. Study shows that Gd-155 and Gd-157 are almost same in suppressing the excess reactivity and it is recommended to enrich both odd number isotopes, Gd-155 and Gd-157. It is estimated that the cycle length increases by 2 days if enriched gadolinia rods are used in the commercial nuclear power plant such as YGN-3 of which the cycle length is assumed 2 years. For the advanced integral reactor SMART in which ultra long cycle length and soluble boron-free operation concept is applied, natural gadolinia burnable absorber rods fail to control the excess reactivity. On the other hand, enriched gadolinia rods are successful in controling the excess reactivity. To minimize power peakings, various placements of gadolinia rods are tested. Also initial reactivity holddown and gadolinia burnout time are parametrized with respect to the number of gadolinia rods and gadolinia weight fractions

  4. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J; Joe, Alexius Y; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger [Department of Nuclear Medicine, University Hospital of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Brink, Ingo [Department of Nuclear Medicine, University Hospital of Freiburg (Germany); Krause, Thomas M [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15{+-}9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256{+-}80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses. (orig.)

  5. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger; Brink, Ingo; Krause, Thomas M.

    2002-01-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15±9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256±80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses. (orig.)

  6. Absorbed Pb2+ and Cd2+ Ions in Water by Cross-Linked Starch Xanthate

    Directory of Open Access Journals (Sweden)

    Kai Feng

    2017-01-01

    Full Text Available A cross-linked starch xanthate was prepared by graft copolymerization of acrylamide and sodium acrylate onto starch xanthate using potassium persulfate and sodium hydrogen sulfite initiating system and N,N′-methylenebisacrylamide as a cross-linker. As this kind of cross-linked potato starch xanthate can effectively absorb heavy metal ions, it was dispersed in aqueous solutions of divalent heavy metal ions (Pb2+ and Cd2+ to investigate their absorbency by the polymer. Factors that can influence absorbency were investigated, such as the ratio of matrix to monomers, the amount of initiator and cross-linker, pH, and the concentration of metal ions. Results were reached and conclusion was drawn that the best synthetic conditions for the polymer adsorbing Pb2+ and Cd2+ were as follows: the quality ratio of matrix to monomers was 1 : 12 and 1 : 11, the amount of initiator was 2.4% and 3.2% of matrix, and the amount of cross-linker was 12 mg and 13 mg. When the initial concentration of ions was 10 mg/L, the highest quantities of adsorption of Pb2+ and Cd2+ were 47.11 mg/g and 36.55 mg/g. Adsorption mechanism was discussed by using Fourier transform infrared (FTIR spectroscopy, X-ray diffraction (XRD, scanning electron microscope (SEM, Energy Dispersive X-Ray Spectroscopy (EDS test, and adsorption kinetic simulation.

  7. Photovoltaic characterization of Copper-Indium-Gallium Sulfide (CIGS2) solar cells for lower absorber thicknesses

    Energy Technology Data Exchange (ETDEWEB)

    Vasekar, Parag S., E-mail: psvasekar@yahoo.co [Florida Solar Energy Center, 1679 Clearlake Rd., Cocoa FL, 32922 (United States); Jahagirdar, Anant H.; Dhere, Neelkanth G. [Florida Solar Energy Center, 1679 Clearlake Rd., Cocoa FL, 32922 (United States)

    2010-01-31

    Chalcopyrites are important contenders among thin-film solar cells due to their direct band gap and higher absorption coefficient. Copper-Indium-Gallium Sulfide (CIGS2) is a chalcopyrite material with a near-optimum band gap of {approx} 1.5 eV. Record efficiency of 11.99% has been achieved on a 2.7 {mu}m CIGS2 film prepared by sulfurization at the Florida Solar Energy Center (FSEC) PV Materials Lab. In this work, photovoltaic performance analysis has been carried out for a 1.5 {mu}m absorber prepared under similar conditions as that of a 2.7 {mu}m thick absorber sample. It was observed that there is an increase in diode factor and reverse saturation current density when the absorber thickness was decreased. The diode factor increased from 1.69 to 2.18 and reverse saturation current density increased from 1.04 x 10{sup -10} mA/cm{sup 2} to 1.78 x 10{sup -8} mA/cm{sup 2}. This can be attributed to a decrease in the grain size when the absorber thickness is decreased. It was also observed that there is an improvement in the shunt resistance. Improvement in shunt resistance can be attributed to optimized value of i:ZnO for lower absorber thickness and less shunting paths due to a smoother absorber.

  8. Photovoltaic characterization of Copper-Indium-Gallium Sulfide (CIGS2) solar cells for lower absorber thicknesses

    International Nuclear Information System (INIS)

    Vasekar, Parag S.; Jahagirdar, Anant H.; Dhere, Neelkanth G.

    2010-01-01

    Chalcopyrites are important contenders among thin-film solar cells due to their direct band gap and higher absorption coefficient. Copper-Indium-Gallium Sulfide (CIGS2) is a chalcopyrite material with a near-optimum band gap of ∼ 1.5 eV. Record efficiency of 11.99% has been achieved on a 2.7 μm CIGS2 film prepared by sulfurization at the Florida Solar Energy Center (FSEC) PV Materials Lab. In this work, photovoltaic performance analysis has been carried out for a 1.5 μm absorber prepared under similar conditions as that of a 2.7 μm thick absorber sample. It was observed that there is an increase in diode factor and reverse saturation current density when the absorber thickness was decreased. The diode factor increased from 1.69 to 2.18 and reverse saturation current density increased from 1.04 x 10 -10 mA/cm 2 to 1.78 x 10 -8 mA/cm 2 . This can be attributed to a decrease in the grain size when the absorber thickness is decreased. It was also observed that there is an improvement in the shunt resistance. Improvement in shunt resistance can be attributed to optimized value of i:ZnO for lower absorber thickness and less shunting paths due to a smoother absorber.

  9. [The LORAS project and quality assurance. In four years from input- to outcome-oriented financing in public health. 2: LORAS project outcome parts 1 & 98].

    Science.gov (United States)

    Lenz, M J; Hochreutener, M A

    2001-04-01

    This series of three articles is a summary of the operations, findings and results of the hospital reform projects in the Canton of Zurich, termed LORAS. With the aid of the LORAS project within four years Zurich hospitals have been transformed. Whereas they used to adhere to input-oriented covering of deficits they now operate with outcome-oriented prospective financing of output. Part 1 describes the whole project. Part 2 focuses on the development of outcome-measurement. Part 3 finally describes the implementation of the outcome-measurement in the canton of Zurich.

  10. Year-round performance of a modified single-basin solar still with mica plate as a suspended absorber

    Energy Technology Data Exchange (ETDEWEB)

    El-Sebaii, A.A.; Aboul-Enein, S.; Ramadan, M.R.I.; El-Bialy, E. [Tanta University (Egypt). Faculty of Science

    2000-01-01

    In a previous study, a single-basin solar still with suspended absorber (SBSSBA) made from aluminium was constructed and investigated experimentally and theoretically. It was found that the daily productivity of the still was about 20% higher than that of the conventional single-basin solar still (SBSS). In this paper, the effect of thermal conductivity of the suspended absorber on the daily productivity of the still is investigated experimentally using aluminium, copper, stainless steel and mica plates as suspended absorbers. The results obtained are compared with those obtained for the SBSS tested under the same climatic conditions of Tanta (lat. 30{sup o} 47' N). The results indicate that it is advisable to use suspended plates made from insulating materials, such as mica, plastic, glass, etc. The daily productivity of the modified still with mica is found to be 42% higher than that of SBSS. Further, the effect of thickness of the suspended absorber on the productivity as well as the year-round performances of both SBSSBA and SBSS for the year 1996 are studied by computer simulation. There is good evidence that the productivity of SBSSBA is less dependent on the thickness of the suspended plate. The annual average productivities of the modified still with mica are found to be 23 and 15.8% higher than those of the conventional still when the basin water masses are 80 and 40 kg, respectively. This indicates that the suspended plate becomes more effective at higher masses of basin water. (author)

  11. Preparation of Ag/SiO{sub 2} near-infrared absorbers using the combination of sputtering and spin-coating depositions

    Energy Technology Data Exchange (ETDEWEB)

    Liau, Leo Chau-Kuang, E-mail: lckliau@saturn.yzu.edu.tw [Department of Chemical Engineering and Materials Science, Yuan Ze University, Chung-Li 320, Taiwan (China); Lai, Guo-Bin [Department of Chemical Engineering and Materials Science, Yuan Ze University, Chung-Li 320, Taiwan (China); Juang, Rei-Cheng; Chang, Bing-Hung [Green Energy and Environmental Laboratories, Industrial Technology Research Institute, Hsinchu 300, Taiwan (China); Yang, Thomas Chun-Kuang [Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan (China)

    2015-03-02

    This study presents the design and fabrication of near-infrared (NIR) absorbers constructed in multilayer structures using Ag and SiO{sub 2} materials. The absorbers, consisting of Ag and SiO{sub 2} films, were fabricated using sputtering and spin-coating approaches, respectively. The fabricated absorbing devices were evaluated using ultraviolet–visible-NIR spectra. Results revealed that the structure of the Ag/SiO{sub 2}/Ag films exhibited an NIR absorbing effect. The absorbing properties were substantially influenced by the fabrication parameters and the thickness of the multilayer films. Furthermore, the NIR absorbing performance improved significantly when the SiO{sub 2} layer was annealed at 300 °C before the deposition of the top Ag film. Additionally, the absorptance of the absorbers was affected by the thickness of the top Ag layer. The long-term stability of the multilayer absorber was tested and verified based on absorptance data analysis. The NIR absorbing performance can be further improved using the optimal device design of the film thickness and by fabricating additional Ag/SiO{sub 2} layers. - Highlights: • Ag/SiO{sub 2} near-infrared absorbers were designed and fabricated. • The absorbing performance was greatly influenced by the fabrication schemes. • The optimal fabrication process of the absorber was obtained. • The long-term stability of the absorber was verified.

  12. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial.

    Science.gov (United States)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif; Webster, Mark; Nieman, Koen; Garcia-Garcia, Hector M; Ormiston, John A; Serruys, Patrick W

    2013-10-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California). Multimodality imaging of the first-in-humans trial using a ABSORB BVS scaffold demonstrated at 2 years the bioresorption of the device while preventing restenosis. However, the long-term safety and efficacy of this therapy remain to be documented. In the ABSORB cohort A trial (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation), 30 patients with a single de novo coronary artery lesion were treated with the fully resorbable everolimus-eluting Absorb scaffold at 4 centers. As an optional investigation in 3 of the 4 centers, the patients underwent multislice computed tomography (MSCT) angiography at 18 months and 5 years. Acquired MSCT data were analyzed at an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) for quantitative analysis of lumen dimensions and was further processed for calculation of fractional flow reserve (FFR) at another independent core laboratory (Heart Flow, Redwood City, California). Five-year clinical follow-up is available for 29 patients. One patient withdrew consent after 6 months, but the vital status of this patient remains available. At 46 days, 1 patient experienced a single episode of chest pain and underwent a target lesion revascularization with a slight troponin increase after the procedure. At 5 years, the ischemia-driven major adverse cardiac event rate of 3.4% remained unchanged. Clopidogrel was discontinued in all but 1 patient. Scaffold thrombosis was not observed in any patient. Two noncardiac deaths were reported, 1 caused by duodenal perforation and the other from Hodgkin's disease. At 5 years, 18 patients underwent MSCT angiography. All scaffolds were patent, with a median minimal lumen area of 3

  13. The Bangladesh clubfoot project: audit of 2-year outcomes of Ponseti treatment in 400 children.

    Science.gov (United States)

    Perveen, Roksana; Evans, Angela M; Ford-Powell, Vikki; Dietz, Frederick R; Barker, Simon; Wade, Paul W; Khan, Shariful I

    2014-01-01

    Congenital clubfoot deformity can cause significant disability, and if left untreated, may further impoverish those in developing countries, like Bangladesh. The Ponseti method has been strategically introduced in Bangladesh by a nongovernment organization, Walk For Life (WFL). WFL has provided free treatment for over 8000 Bangladeshi children with clubfeet, sustained by local ownership, and international support. This audit assesses the 2-year results in children for whom treatment began before the age of 3 years. The 10 largest WFL clinics, of the 24 across Bangladesh, were pragmatically accessed in this audit availing 1442 subjects meeting the study criteria, from which 400 children were randomly selected and examined. A specific assessment tool was developed and validated. Results for 400 cases were returned: 269 males, 131 females. Typical clubfeet comprised 79% of cases, and 55% were bilateral. A tenotomy rate of 79%, and brace use after 2 years of 85%, were notable findings. Functionally, most children could walk independently (99.0%), run (95.5%), squat (93.3%), and manage steps unassisted (93.0%). The ability to squat was the most indicative outcome measure, correlating with: less corrective casts, good and continued brace use, nonvarus heel position, good ankle range of motion, good Bangla clubfoot scores, and the ability to walk. Relapsing deformity was suspected with heel varus (18.0% left; 21.5% right). Parental satisfaction was very high, but cost of 3000 Taka ($US 38.48) was deemed unaffordable by 59%. The outcomes in young children after 2 years of Ponseti treatment for clubfoot deformity showed that 99% were able to walk independently. The assessment tool developed for this study avails ongoing monitoring. Without the patronage of WFL, most of these children would not have had access to treatment, and be unable to walk. Level II-lesser-quality prospective study.

  14. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger [Department of Nuclear Medicine, University Hospital of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Brink, Ingo [Department of Nuclear Medicine, University Hospital of Freiburg (Germany); Krause, Thomas M. [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15{+-}9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256{+-}80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses

  15. Two-year outcomes of transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Poh, Seng Yew; Yue, Wai Mun; Chen, Li-Tat John; Guo, Chang-Ming; Yeo, William; Tan, Seang-Beng

    2011-08-01

    To evaluate the outcomes, fusion rates, complications, and adjacent segment degeneration associated with transforaminal lumbar interbody fusion (TLIF). 32 men and 80 women aged 15 to 85 (mean, 57) years underwent 141 fusions (84 one-level, 27 2-level, and one 3-level) and were followed up for 24 to 76 (mean, 33) months. 92% of the patients had degenerative lumbar disease, 15 of whom had had previous lumbar surgery. Radiographic and clinical outcomes were assessed at 2 years. The short-form 36 (SF-36) health survey, visual analogue scale (VAS) for pain, and the modified North American Spine Society (NASS) Low Back Pain Outcome Instrument were used. Of the 141 levels fused, 110 (78%) were fused with remodelling and trabeculae (grade I), and 31 (22%) had intact grafts but were not fully incorporated (grade II). No patient had pseudoarthroses (grade III or IV). For one-level fusions, poorer radiological fusion grades correlated with higher VAS scores for pain (p<0.01). All components of the SF-36, the VAS scores for pain, and the NASS scores improved significantly after TLIF (p<0.01), except for general health in the SF-36 (p=0.59). Improvement from postoperative 6 months to 2 years was not significant, except for physical function (p<0.01) and role function (physical) [p=0.01] in the SF-36. Two years after TLIF, 50% of the patients reported returning to full function, whereas 72% were satisfied. 26 (23%) of the patients had adjacent segment degeneration, but only 4 of them were symptomatic. TLIF is a safe and effective treatment for degenerative lumbar diseases.

  16. The COMMENCE trial: 2-year outcomes with an aortic bioprosthesis with RESILIA tissue.

    Science.gov (United States)

    Puskas, John D; Bavaria, Joseph E; Svensson, Lars G; Blackstone, Eugene H; Griffith, Bartley; Gammie, James S; Heimansohn, David A; Sadowski, Jerzy; Bartus, Krzysztof; Johnston, Douglas R; Rozanski, Jacek; Rosengart, Todd; Girardi, Leonard N; Klodell, Charles T; Mumtaz, Mubashir A; Takayama, Hiroo; Halkos, Michael; Starnes, Vaughn; Boateng, Percy; Timek, Tomasz A; Ryan, William; Omer, Shuab; Smith, Craig R

    2017-09-01

    The COMMENCE trial was conducted to evaluate the safety and effectiveness of a novel bioprosthetic tissue for surgical aortic valve replacement (AVR). Patients underwent clinically indicated surgical AVR with the Carpentier-Edwards PERIMOUNT™ Magna Ease™ aortic valve with RESILIA™ tissue (Model 11000A) in a prospective, multinational, multicentre (n = 27), single-arm, FDA Investigational Device Exemption trial. Events were adjudicated by an independent Clinical Events Committee; echocardiograms were analysed by an independent Core Laboratory. Between January 2013 and February 2016, 689 patients received the study valve. Mean age was 67.0 ± 11.6 years; 71.8% were male; 26.3% were New York Heart Association Class III/IV. Mean STS PROM was 2.0 ± 1.8 (0.3-17.5). Isolated AVR was performed in 59.1% of patients; others had additional concomitant procedures, usually CABG. Thirty-day outcomes for all patients included all-cause mortality 1.2%, thromboembolism 2.2%, bleeding 0.9%, major paravalvular leak 0.1% and permanent pacemaker implantation 4.7%. Median intensive care unit and hospital length of stay were 2 (range: 0.2-66) and 7 days (3.0-121.0), respectively. At 2years, New York Heart Association class improved in 65.7%, effective orifice area was 1.6 ± 0.5 cm2; mean gradient was 10.1 ± 4.3 mmHg; and paravalvular leak was none/trivial in 94.5%, mild in 4.9%, moderate in 0.5% and severe in 0.0%. One-year actuarial freedom from all-cause mortality for isolated AVR and for all patients was 98.2% and 97.6%, respectively. Two-year actuarial freedom from mortality in these groups was 95.3% and 94.3%, respectively. These data demonstrate excellent early safety and effectiveness of aortic valve replacement with a novel bioprosthetic tissue (RESILIA™). clinicaltrials.gov: NCT01757665. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Gaseous saturable absorbers for the Helios CO2 laser system

    International Nuclear Information System (INIS)

    Haglund, R.F. Jr.; Nowak, A.V.; Czuchlewski, S.J.

    1981-01-01

    Saturable absorbers are widely used to suppress parasitic oscillations in large-aperture, high-power CO 2 fusion-laser systems. We report experimental results on SF 6 -based gaseous saturable absorbers used for parasitic suppression in the eight-beam, 10 kJ Helios fusion-laser system. The gas mix effectively quenches self-lasing in the 9 and 10 μm branches of the CO 2 laser spectrum while simultaneously allowing high transmission of subnanosecond multiwavelength pulses for target-irradiation experiments. The gas isolator now in use consists of SF 6 and the additional fluorocarbons: 1, 1-difluoroethane (FC-152a); dichlorodifluoromethane (FC-12); chloropentafluoroethane (FC-115); 1,1-dichloro 2,2-difluoroethylene (FC-1112a); chlorotrifluoroethylene (FC-1113); and perfluorocyclobutane (FC-C318). The saturation of the mix was studied as a function of incident fluence, pressure, cell length, and incident wavelength. Experimental results are presented on the saturation properties of pure SF 6 and FC-152a and compared with the saturation behavior of CO 2 at 400 0 C

  18. The Properties of Quasar 2175 Å Dust Absorbers at z = 1.0-2.5

    Science.gov (United States)

    Ma, Jingzhe; Ge, Jian; Prochaska, Jason; Zhao, Yinan; Zhang, Shaohua; Ji, Tuo; Lundgren, Britt; Zhou, Hongyan; Lu, Honglin; Schneider, Donald

    2018-01-01

    Quasar 2175 Å dust absorbers (2DAs) are a population of quasar absorption line systems identified by the broad absorption feature centered around rest-frame 2175 Å, which is ubiquitously seen in the Milky Way extinction curves. These absorbers are excellent tracers of gas and dust properties, metal abundances, chemical evolution, physical conditions, as well as kinematics in the absorbing galaxies. We present the metallicity, depletion pattern, kinematics, and the cold neutral content (HI and CI gas) of a sample of 2DAs at z = 1.0-2.5 that were initially selected from the Sloan Digital Sky Survey and followed up with Keck and MMT spectrographs. We perform a correlation analysis between metallicity, redshift, depletion level, velocity width, and explore relationships between 2DAs and other absorption line systems. The 2DAs on average have higher metallicity, higher depletion levels, and larger velocity widths than Damped Lyman-α absorbers (DLAs) or subDLAs. The correlation between [Zn/H] and [Fe/Zn] or [Zn/H] and logΔV90 can be used as alternative stellar mass estimators based on the well-established mass-metallicity relation. The relationship with other quasar absorption line systems can be described as (1) 2DAs are a subset of Mg II and Fe II absorbers, (2) 2DAs are preferentially metal-strong DLAs/subDLAs, (3) More importantly, all of the 2DAs show CI detections with N(CI) > 14.0 cm-2, (4) 2DAs can be used as molecular gas tracers. Their host galaxies are likely to be chemically enriched, evolved, and massive galaxies (more massive than typical DLA/subDLA galaxies). In addition, we have, for the first time, identified the host galaxy of a 2DA beyond the local Universe using HST IR direct imaging and grism spectroscopy.

  19. Air-Leak Effects on Ear-Canal Acoustic Absorbance

    Science.gov (United States)

    Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.

    2015-01-01

    Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables

  20. Measurements and analyses on reactivity effects of absorber rods in a light-water moderated UO2 lattices

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Miyoshi, Yoshinori; Hirose, Hideyuki; Suzaki, Takenori

    1985-03-01

    Reactivity effects and reactivity-interference effects of absorber rods were measured with a cylindrical core aiming to obtain bench-marks for verification of the calculational methods. The core consisted of 2.6 w/o enriched UO 2 fuel rods lattice of which water-to-fuel volume ratio was 1.83. In the experiment, the critical water levels were measured changing neutron absorber content of absorber rods and the distance between two absorber rods in the core center. Monte Calro codes KENO-IV and MULTI-KENO were used to calculate reactivity worthes of absorber rods. The calculational results of effective multiplication factors ranged from 0.978 to 0.999 for the 60 cases of critical cores with inserted absorber rods. The calculational results of absorber worthes agreed to the experimental results within twice of the standerd deviation accompanied with the Monte Calro calculation. (author)

  1. Development of CIGS2 solar cells with lower absorber thickness

    Energy Technology Data Exchange (ETDEWEB)

    Vasekar, Parag S.; Dhere, Neelkanth G. [Florida Solar Energy Center, University of Central Florida, 1679 Clearlake Rd., Cocoa, FL 32922 (United States); Moutinho, Helio [National Renewable Energy Laboratory, 1617 Cole Blvd. Golden, CO 80401 (United States)

    2009-09-15

    The availability and cost of materials, especially of indium can be a limiting factor as chalcopyrite based thin-film solar cells advance in their commercialization. The required amounts of metals can be lowered by using thinner films. When the thickness of the film decreases, there is possibility of remaining only in the small grain region because the coalescence of grains does not have an opportunity to enhance the grain size to the maximum. Solar cell performance in smaller grain chalcopyrite absorber deteriorates due to larger fraction of grain boundaries. Efforts are being made to reduce the thickness while maintaining the comparable performance. This work presents a study of preparation, morphology and other material properties of CIGS2 absorber layers with decreasing thicknesses up to 1.2 {mu}m and its correlation with the device performance. Encouraging results were obtained demonstrating that reasonable solar cell efficiencies (>10%) can be achieved even for thinner CIGS2 thin-film solar cells. (author)

  2. Evaluation of 2-year outcomes following intravitreal bevacizumab (IVB for aggressive posterior retinopathy of prematurity

    Directory of Open Access Journals (Sweden)

    Murat Gunay

    2015-10-01

    Full Text Available ABSTRACTPurpose:To evaluate 2-year outcomes following intravitreal bevacizumab (IVB as monotherapy for aggressive posterior retinopathy of prematurity (APROP.Methods:Medical records of 40 infants were retrospectively reviewed. Group I included infants who had received IVB injections for APROP. Group II included infants who underwent laser treatment for APROP. Anatomic and refractive outcomes and the presence of anisometropia and strabismus were assessed at follow-up examinations.Results:Group I included 48 eyes of 25 infants (11 males with a mean gestational age (GA of 26.40 ± 1.82 weeks and a mean birth weight (BW of 901.40 ± 304.60 g. Group II included 30 eyes of 15 infants (6 males with a mean GA of 27.30 ± 1.82 weeks and a mean BW of 941.00 ± 282.48 g. GA, BW, and gender distributions were similar between groups (P=0.187, P=0.685, and P=1.000, respectively. Refractive errors were significantly less myopic in group I (0.42 ± 3.42 D than in group II (-6.66 ± 4.96 D at 2 years (P=0.001. Significantly higher rates of anisometropia and strabismus were observed in group II than in group I (P=0.009 and P=0.036, respectively.Conclusions:The study demonstrated that IVB monotherapy can be useful in the treatment of APROP. The decreased incidence of early unfavorable refractive and functional outcomes in the IVB group compared with the laser group showed a potential benefit for patients treated with IVB, and this needs to be better evaluated in future prospective studies.

  3. Academic Outcomes 2 Years After Working Memory Training for Children With Low Working Memory: A Randomized Clinical Trial.

    Science.gov (United States)

    Roberts, Gehan; Quach, Jon; Spencer-Smith, Megan; Anderson, Peter J; Gathercole, Susan; Gold, Lisa; Sia, Kah-Ling; Mensah, Fiona; Rickards, Field; Ainley, John; Wake, Melissa

    2016-05-02

    Working memory training may help children with attention and learning difficulties, but robust evidence from population-level randomized controlled clinical trials is lacking. To test whether a computerized adaptive working memory intervention program improves long-term academic outcomes of children 6 to 7 years of age with low working memory compared with usual classroom teaching. Population-based randomized controlled clinical trial of first graders from 44 schools in Melbourne, Australia, who underwent a verbal and visuospatial working memory screening. Children were classified as having low working memory if their scores were below the 15th percentile on either the Backward Digit Recall or Mister X subtest from the Automated Working Memory Assessment, or if their scores were below the 25th percentile on both. These children were randomly assigned by an independent statistician to either an intervention or a control arm using a concealed computerized random number sequence. Researchers were blinded to group assignment at time of screening. We conducted our trial from March 1, 2012, to February 1, 2015; our final analysis was on October 30, 2015. We used intention-to-treat analyses. Cogmed working memory training, comprising 20 to 25 training sessions of 45 minutes' duration at school. Directly assessed (at 12 and 24 months) academic outcomes (reading, math, and spelling scores as primary outcomes) and working memory (also assessed at 6 months); parent-, teacher-, and child-reported behavioral and social-emotional functioning and quality of life; and intervention costs. Of 1723 children screened (mean [SD] age, 6.9 [0.4] years), 226 were randomized to each arm (452 total), with 90% retention at 1 year and 88% retention at 2 years; 90.3% of children in the intervention arm completed at least 20 sessions. Of the 4 short-term and working memory outcomes, 1 outcome (visuospatial short-term memory) benefited the children at 6 months (effect size, 0.43 [95% CI, 0

  4. Effect of the bio-absorbent on the microwave absorption property of the flaky CIPs/rubber absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yang; Xu, Yonggang, E-mail: xuyonggang221@163.com; Cai, Jun; Yuan, Liming; Zhang, Deyuan

    2015-09-01

    Microwave absorbing composites filled with flaky carbonyl iron particles (CIPs) and the bio-absorbent were prepared by using a two-roll mixer and a vulcanizing machine. The electromagnetic (EM) parameters were measured by a vector network analyzer and the reflection loss (RL) was measured by the arch method in the frequency range of 1–4 GHz. The uniform dispersion of the absorbents was verified by comparing the calculated RL with the measured one. The results confirm that as the bio-absorbent was added, the permittivity was increased due to the volume content of absorbents, and the permeability was enlarged owing to the volume content of CIPs and interactions between the two absorbents. The composite filled with bio-absorbents achieved an excellent absorption property at a thickness of 1 mm (minimum RL reaches −7.8 dB), and as the RL was less than −10 dB the absorption band was widest (2.1–3.8 GHz) at a thickness of 2 mm. Therefore, the bio-absorbent is a promising additive candidate on fabricating microwave absorbing composites with a thinner thickness and wider absorption band. - Graphical abstract: Morphology of composites filled with flaky CIPs and the bio-absorbent. The enhancement of bio-absorbent on the electromagnetic absorption property of composites filled with flaky carbonyl iron particles (CIPs) is attributed to the interaction of the two absorbents. The volume content of the FCMPs with the larger shape CIPs play an important role in this effects, the composites filled with irons and bio-absorbents can achieve wider-band and thinner-thickness absorbing materials. - Highlights: • Absorbers filled with bio-absorbents and CIPs was fabricated. • Bio-absorbents enhanced the permittivity and permeability of the composites. • The absorbent interactions play a key role in the enhancement mechanism. • Bio-absorbents enhanced the composite RL in 1–4 GHz.

  5. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    Science.gov (United States)

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017

  6. A randomised controlled trial of absorbable versus non-absorbable sutures for skin closure after open carpal tunnel release.

    LENUS (Irish Health Repository)

    Theopold, C

    2012-05-01

    We compared the aesthetic outcome of scars after closure of open carpal tunnel incisions with either absorbable 4-0 Vicryl Rapide or non-absorbable 4-0 Novafil. Patients were recruited in a randomized controlled trial and scars were scored at 6 weeks using a modified Patient and Observer Scar Assessment Scale. Scores demonstrated differences only for pain, vascularity and cross-hatching between both groups, though none of these were statistically significant. The dissolving and falling out of Vicryl Rapide was significantly more comfortable than removal of 4-0 Novafil sutures, assessed on a numerical analogue scale. There was no difference in infection rate between both study groups, supporting overall the use of Vicryl Rapide for the closure of palmar hand incisions, in light of the convenience and cost savings associated with absorbable sutures.

  7. How Satisfied Are Patients with Arthroscopic Bankart Repair? A 2-Year Follow-up on Quality-of-Life Outcome.

    Science.gov (United States)

    Saier, Tim; Plath, Johannes E; Waibel, Sabrina; Minzlaff, Philipp; Feucht, Matthias J; Herschbach, Peter; Imhoff, Andreas B; Braun, Sepp

    2017-10-01

    To report general life and health satisfaction after arthroscopic Bankart repair in patients with post-traumatic recurrent anterior glenohumeral instability and to investigate postoperative time lost to return to work at 2-year follow-up. Between 2011 and 2013 patients treated with arthroscopic Bankart repair in the beach chair position for acute shoulder instability were included in this study. Questions on Life Satisfaction Modules (FLZ M ) and the Short Form 12 (SF-12) were used as quality-of-life outcome scales. Oxford Instability Score (OIS), Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), and self-reported American Shoulder and Elbow Surgeons (ASES) shoulder index were used as functional outcome scales. Return to work (months) was monitored and analyzed depending on physical workload. Data were assessed the day before surgery and prospectively monitored until 24 months postoperatively. Quality-of-life outcome was correlated with functional shoulder outcome and compared with normative age-adjusted data. Paired t-test, Wilcoxon test, Mann-Whitney U-Test, and Spearman's correlation coefficient were used for statistical analysis. Fifty-three patients were prospectively included. The mean age at surgery was 29.4 years. Satisfaction with general life and satisfaction with health (FLZ M ) as well as physical component scale (SF-12) improved significantly to values above normative data within 6 to 12 months after surgery (each P quality of life and functional outcome scores (P work was 2 months (range, 0-10; standard deviation, 1.9), with significantly longer time intervals observed in patients with heavy physical workload (3.1 months; range, 0 to 10; standard deviation, 2.4; P = .002). Following arthroscopic Bankart repair, quality of life was impaired during early course after surgery and increased significantly above preoperative levels within 6 to 12 months after the procedure. A steady state of excellent quality-of-life and

  8. Stereotactic radiofrequency amygdalohippocampectomy: Two years of good neuropsychological outcomes

    Czech Academy of Sciences Publication Activity Database

    Malíková, H.; Krámská, L.; Vojtěch, Z.; Lukavský, Jiří; Liščák, R.

    2013-01-01

    Roč. 106, č. 3 (2013), s. 423-432 ISSN 0920-1211 Institutional support: RVO:68081740 Keywords : temporal lobe epilepsy * stereotactic surgery * neuropsychology outcome Subject RIV: AN - Psychology Impact factor: 2.190, year: 2013

  9. Meniscus suture repair: minimum 10-year outcomes in patients younger than 40 years compared with patients 40 and older.

    Science.gov (United States)

    Steadman, J Richard; Matheny, Lauren M; Singleton, Steven B; Johnson, Nicholas S; Rodkey, William G; Crespo, Bernardo; Briggs, Karen K

    2015-09-01

    Few studies have compared outcomes after meniscus suture repair in patients younger than 40 years versus patients 40 years and older. To document failure rates and long-term outcomes after meniscus suture repair by a single surgeon, using the inside-out technique, at a minimum 10-year follow-up in patients younger than 40 years versus those 40 years and older. Cohort study; Level of evidence, 3. This study included all patients 18 years or older who underwent meniscus suture repair with the inside-out technique by a single surgeon between January 1992 and December 2003. Patients were divided into 2 cohorts according to age: meniscus as repaired in the index surgery. Patients completed a subjective questionnaire at minimum of 10 years after arthroscopy. Outcomes measures included Lysholm, Tegner, and patient satisfaction with outcome. All data were collected prospectively. The surgeon performed 339 meniscus repairs between 1992 and 2003. The study included 181 knees in 178 patients, who had a mean age of 33 years (range, 18-70 years). Cohort 1 contained 136 knees; 16 patients (12%) were lost to follow-up and 47 (35%) underwent a subsequent knee arthroscopy. Cohort 2 contained 45 knees; 2 patients (4.4%) were lost to follow-up, 3 patients had a total knee arthroplasty, and 12 patients (28%) underwent a subsequent knee arthroscopy. In cohort 1, the meniscus repair failure rate was 5.5% (6/110), and in cohort 2 it was 5.3% (2/38) (P = .927). There was no significant difference in failure rate based on which meniscus was repaired (P = .257), concomitant anterior cruciate ligament (ACL) reconstruction (P = .092), or microfracture (P = .674). Average follow-up time for cohort 1 was 16.1 years (range, 10.0-21.9 years), with 82% follow-up (n = 73/89); average follow-up time for cohort 2 was 16.2 years (range, 10.1-21.0 years), with 93% follow-up (n = 28/30). There were no significant differences in outcomes scores after meniscus suture repair based on age cohort or meniscus

  10. Burnable neutron absorbers

    International Nuclear Information System (INIS)

    Radford, K.C.; Carlson, W.G.

    1983-01-01

    A neutron-absorber body for use in burnable poison rods in a nuclear reactor. The body is composed of a matrix of Al 2 O 3 containing B 4 C, the neutron absorber. Areas of high density polycrystalline Al 2 O 3 particles are predominantly encircled by pores in some of which there are B 4 C particles. This body is produced by initially spray drying a slurry of A1 2 O 3 powder to which a binder has been added. The powder of agglomerated spheres of the A1 2 O 3 with the binder are dry mixed with B 4 C powder. The mixed powder is formed into a green body by isostatic pressure and the green body is sintered. The sintered body is processed to form the neutron-absorber body. In this case the B 4 C particles are separate from the spheres resulting from the spray drying instead of being embedded in the sphere

  11. Impact of speciation on CO{sub 2} capture performance using blended absorbent containing ammonia, triethanolamine and 2-amino-2-methyl-1-propanol

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hao-Yang; Jeon, Soo-Bin; Jang, Se-Yong; Oh, Kwang-Joong [Pusan National University, Busan (Korea, Republic of); Lee, Sang-Sup [Chungbuk National University, Cheongju (Korea, Republic of); Kang, Seong-Kuy [BK Environmental Construction, Suwon (Korea, Republic of)

    2014-07-15

    In our previous study, a high CO{sub 2} absorption rate was achieved using a blended absorbent containing AMP, NH{sub 3}, and TEA. The species of the blended absorbent was determined in this study using {sup 13}C nuclear magnetic resonance (NMR) spectroscopy and a modified Kent-Eisenberg model. The carbamate formation constant was also regressed using the model. Bicarbonate and carbonate ions decrease the absorption efficiency and have a positive effect on CO{sub 2} stripping. Carbamate has a negative effect on regeneration; a regeneration temperature of 373 K minimized the energy needed. In conclusion, the prediction equation and NMR analysis provide an easy way of determining carbonate group species and carbamate species concentrations, and this method will be helpful in optimizing CO{sub 2} capture with blended absorbents.

  12. Mid-term study of transcatheter aortic valve implantation in an Asian population with severe aortic stenosis: two-year Valve Academic Research Consortium-2 outcomes.

    Science.gov (United States)

    Chew, Nicholas; Hon, Jimmy Kim Fatt; Yip, Wei Luen James; Chan, Siew Pang; Poh, Kian-Keong; Kong, William Kok-Fai; Teoh, Kristine Leok Kheng; Yeo, Tiong Cheng; Tan, Huay Cheem; Tay, Edgar Lik Wui

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) is an effective treatment for high-risk or inoperative patients with severe aortic stenosis. Given the unique characteristics of Asian populations, questions regarding mid-term outcomes in Asians undergoing TAVI have yet to be addressed. We evaluated the two-year clinical outcomes of TAVI in an Asian population using Valve Academic Research Consortium-2 definitions. This prospective study recruited 59 patients from a major academic medical centre in Singapore. The main outcomes were two-year survival rates, peri-procedural complications, symptom improvement, valvular function and assessment of learning curve. Mean age was 76.8 years (61.0% male), mean body surface area 1.6 m 2 and mean logistic EuroSCORE 18.7%. Survival was 93.2%, 86.0% and 79.1% at 30 days, one year and two years, respectively. At 30 days post TAVI, the rate of stroke was 1.7%, life-threatening bleeding 5.1%, acute kidney injury 25.0%, major vascular complication 5.1%, and new permanent pacemaker implantation 6.8%. 29.3% of TAVI patients were rehospitalised (47.1% cardiovascular-related) within one year. These composite outcomes were measured: device success (93.2%); early safety (79.7%); clinical efficacy (66.1%); and time-related valve safety (84.7%). Univariate analysis found these predictors of two-year all-cause mortality: logistic EuroSCORE (hazard ratio [HR] 1.07; p < 0.001); baseline estimated glomerular filtration rate (HR 0.97; p = 0.048); and acute kidney injury (HR 5.33; p = 0.022). Multivariate analysis identified non-transfemoral TAVI as a predictor of cardiovascular-related two-year mortality (HR 14.64; p = 0.008). Despite the unique clinical differences in Asian populations, this registry demonstrated favourable mid-term clinical and safety outcomes in Asians undergoing TAVI. Copyright: © Singapore Medical Association

  13. Patient-reported outcome 2 years after lung transplantation: does the underlying diagnosis matter?

    Directory of Open Access Journals (Sweden)

    Ghosh S

    2012-11-01

    Full Text Available Maria Jose Santana,1 David Feeny,2 Sunita Ghosh,3 Dale C Lien41Faculty of Medicine, University of Calgary, Calgary, Alberta, Canada; 2Kaiser Permanente Center for Health Research, Portland, OR, USA; 3Cross Cancer Center, University of Alberta, Edmonton, Alberta, Canada; 4University of Alberta Hospital, Edmonton, Alberta, CanadaPurpose: Transplantation has the potential to produce profound effects on survival and health-related quality of life (HRQL. The inclusion of the patient’s perspective may play an important role in the assessment of the effectiveness of lung transplantation. Patient perspectives are assessed by patient-reported outcome measures, including HRQL measures. We describe how patients’ HRQL among different diagnosis groups can be used by clinicians to monitor and evaluate the outcomes associated with transplantation.Methods: Consecutive lung transplant recipients attending the lung transplant outpatient clinic in a tertiary institution completed the 15-item Health Utilities Index (HUI questionnaire on a touchscreen computer. The results were available to clinicians at every patient visit. The HUI3 covers a range of severity and comorbidities in eight dimensions of health status. Overall HUI3 scores are on a scale in which dead = 0.00 and perfect health = 1.00; disability categories range from no disability = 1 to severe disability <0.70. Single-attribute and overall HUI3 scores were used to compare patients’ HRQL among different diagnosis groups. Random-effect models with time since transplant as a random variable and age, gender, underlying diagnoses, infections, and broncholitis obliterans syndrome as fixed variables were built to identify determinants of health status at 2-years posttransplantation.Results: Two hundred and fourteen lung transplant recipients of whom 61% were male with a mean age of 52 (19–75 years were included in the study. Chronic obstructive pulmonary disease and cystic fibrosis patients displayed

  14. A Ten-Year Global Record of Absorbing Aerosols Above Clouds from OMI's Near-UV Observations

    Science.gov (United States)

    Jethva, Hiren; Torres, Omar; Ahn, Changwoo

    2016-01-01

    Aerosol-cloud interaction continues to be one of the leading uncertain components of climate models, primarily due to the lack of an adequate knowledge of the complex microphysical and radiative processes associated with the aerosol-cloud system. The situations when aerosols and clouds are found in the same atmospheric column, for instance, when light-absorbing aerosols such as biomass burning generated carbonaceous particles or wind-blown dust overlay low-level cloud decks, are commonly found over several regional of the world. Contrary to the cloud-free scenario over dark surface, for which aerosols are known to produce a net cooling effect (negative radiative forcing) on climate, the overlapping situation of absorbing aerosols over cloud can potentially exert a significant level of atmospheric absorption and produces a positive radiative forcing at top-of-atmosphere. The magnitude of direct radiative effects of aerosols above cloud depends directly on the aerosol loading, microphysical-optical properties of the aerosol layer and the underlying cloud deck, and geometric cloud fraction. We help in addressing this problem by introducing a novel product of optical depth of absorbing aerosols above clouds retrieved from near-UV observations made by the Ozone Monitoring Instrument (OMI) on board NASA's Aura platform. The presence of absorbing aerosols above cloud reduces the upwelling radiation reflected by cloud and produces a strong 'color ratio' effect in the near-UV region, which can be unambiguously detected in the OMI measurements. Physically based on this effect, the OMACA algorithm retrieves the optical depths of aerosols and clouds simultaneously under a prescribed state of atmosphere. The algorithm architecture and results from a ten-year global record including global climatology of frequency of occurrence and above-cloud aerosol optical depth, and a discussion on related future field campaigns are presented.

  15. Black Cr/α-Cr2O3 nanoparticles based solar absorbers

    International Nuclear Information System (INIS)

    Khamlich, S.; Nemraoui, O.; Mongwaketsi, N.; McCrindle, R.; Cingo, N.; Maaza, M.

    2012-01-01

    Monodisperse spherical core–shell particles of Cr/α-Cr 2 O 3 with high adhesion were successfully coated on rough copper substrates by a simple self-assembly-like method for the use in solar thermal absorbers. The structure and morphology of the core-shell particles of Cr/α-Cr 2 O 3 were effectively controlled by deposition temperature and the pH of the initial precursor solution. Their characterizations were carried out with X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry and attenuated total reflection, as well as UV–vis diffuse reflectance spectroscopy. The samples aged for more than 40 h at 75 °C exhibit the targeted high absorbing optical characteristic “Black chrome” while those aged for ≤40 h show a significant high UV–vis diffuse reflectance “green color”.

  16. Design of broadband absorber using 2-D materials for thermo-photovoltaic cell application

    Science.gov (United States)

    Agarwal, Sajal; Prajapati, Y. K.

    2018-04-01

    Present study is done to analyze a nano absorber for thermo-photovoltaic cell application. Optical absorbance of two-dimensional materials is exploited to achieve high absorbance. It is found that few alternating layers of graphene/transition metal dichalcogenide provide high absorbance of electromagnetic wave in visible as well as near infrared region. Four transition metal dichalcogenides are considered and found that most of these provide perfect absorbance for almost full considered wavelength range i.e. 200-1000 nm. Demonstrated results confirm the extended operating region and improved absorbance of the proposed absorber in comparison to the existing absorbers made of different materials. Further, absorber performance is improved by using thin layers of gold and chromium. Simple geometry of the proposed absorber also ensures easy fabrication.

  17. Radiation sterilization of absorbent cotton and of absorbent gauze

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari; Oka, Mitsuru; Kaneko, Akira; Ishiwata, Hiroshi.

    1986-01-01

    The bioburden of absorbent cotton and of absorbent gauze and their physical and chemical characteristics after irradiation are investigated. The survey conducted on contaminants of 1890 cotton samples from 53 lots and 805 gauze samples from 56 lots showed maximum numbers of microbes per g of the cotton and gauze were 859 (an average of 21.4) and 777 (an average of 42.2), respectively. Isolation and microbiological and biochemical tests of representative microbes indicated that all of them, except one, were bacilli. The sterilization dose at 10 -6 of sterlity assurance level was found to be 2.0 Mrad when irradiated the spores loaded on paper strips and examined populations having graded D values from 0.10 to 0.28 Mrad. The sterilization dose would be about 1.5 Mrad if subjected the average numbers of contaminants observed in this study to irradiation. No significant differences were found between the irradiated samples and control up to 2 Mrad in tensile strength, change of color, absorbency, sedimentation rate, soluble substances, and pH of solutions used for immersion and other tests conventionally used. These results indicate that these products can be sterilized by irradiation. (author)

  18. Impact of burnable absorber Gd on nuclide composition for VVER-440 fuel (Gd-2)

    International Nuclear Information System (INIS)

    Zajac, R.; Chrapciak, V.

    2010-01-01

    The latest version of Russian fuel VVER-440 includes burnable absorber in 6 pins. In this article is impact of burnable absorber on nuclide composition and criticality analyzed. In part 1 was analyzed whole burnup interval 0-50 MWd/kgU. In present part 2 are detailed analysis only for first cycle (burnup 0-10 MWd/kgU). (Authors)

  19. Transition metal atoms absorbed on MoS2/h-BN heterostructure: stable geometries, band structures and magnetic properties.

    Science.gov (United States)

    Wu, Yanbing; Huang, Zongyu; Liu, Huating; He, Chaoyu; Xue, Lin; Qi, Xiang; Zhong, Jianxin

    2018-06-15

    We have studied the stable geometries, band structures and magnetic properties of transition-metal (V, Cr, Mn, Fe, Co and Ni) atoms absorbed on MoS2/h-BN heterostructure systems by first-principles calculations. By comparing the adsorption energies, we find that the adsorbed transition metal (TM) atoms prefer to stay on the top of Mo atoms. The results of the band structure without spin-orbit coupling (SOC) interaction indicate that the Cr-absorbed systems behave in a similar manner to metals, and the Co-absorbed system exhibits a half-metallic state. We also deduce that the V-, Mn-, Fe-absorbed systems are semiconductors with 100% spin polarization at the HOMO level. The Ni-absorbed system is a nonmagnetic semiconductor. In contrast, the Co-absorbed system exhibits metallic state, and the bandgap of V-absorbed system decreases slightly according to the SOC calculations. In addition, the magnetic moments of all the six TM atoms absorbed on the MoS2/h-BN heterostructure systems decrease when compared with those of their free-standing states.

  20. Outcomes of a New Residential Scheme for Adults with Intellectual Disabilities in Taiwan: A 2-Year Follow-Up

    Science.gov (United States)

    Chou, Y-C.; Pu, C.; Kroger, T.; Lee, W.; Chang, S.

    2011-01-01

    Background: The Taiwanese government launched a new programme in November 2004 to support adults with intellectual disabilities living in smaller facilities. This paper aims to evaluate the service outcomes of this new residential scheme over 2 years including those residents who moved from an institution and those who moved from their family.…

  1. Neutron absorbing article

    International Nuclear Information System (INIS)

    Naum, R.G.; Owens, D.P.; Dooker, G.I.

    1981-01-01

    A neutron-absorbing article suitable for use in spent fuel racks is described. It comprises boron carbide particles, diluent particles, and a phenolic polymer cured to a continuous matrix. The diluent may be silicon carbide, graphite, amorphous carbon, alumina, or silica. The combined boron carbide-diluent phase contains no more than 2 percent B 2 O 3 , and the neutron-absorbing article contains from 20 to 40 percent phenol resin. The ratio of boron carbide to diluent particles is in the range 1:9 to 9:1

  2. Designing a hand rest tremor dynamic vibration absorber using H2 optimization method

    International Nuclear Information System (INIS)

    Rahnavard, Mostafa; Dizaji, Ahmad F.; Hashemi, Mojtaba; Faramand, Farzam

    2014-01-01

    An optimal single DOF dynamic absorber is presented. A tremor has a random nature and then the system is subjected to a random excitation instead of a sinusoidal one; so the H 2 optimization criterion is probably more desirable than the popular H ∞ optimization method and was implemented in this research. The objective of H 2 optimization criterion is to reduce the total vibration energy of the system for overall frequencies. An objective function, considering the elbow joint angle, θ 2 , tremor suppression as the main goal, was selected. The optimization was done by minimization of this objective function. The optimal system, including the absorber, performance was analyzed in both time and frequency domains. Implementing the optimal absorber, the frequency response amplitude of θ 2 was reduced by more than 98% and 80% at the first and second natural frequencies of the primary system, respectively. A reduction of more than 94% and 78%, was observed for the shoulder joint angle, θ 1 . The objective function also decreased by more than 46%. Then, two types of random inputs were considered. For the first type, θ 1 and θ 2 revealed 60% and 39% reduction in their rms values, whereas for the second type, 33% and 50% decrease was observed.

  3. Reflection measurements of microwave absorbers

    Science.gov (United States)

    Baker, Dirk E.; van der Neut, Cornelis A.

    1988-12-01

    A swept-frequency interferometer is described for making rapid, real-time assessments of localized inhomogeneities in planar microwave absorber panels. An aperture-matched exponential horn is used to reduce residual reflections in the system to about -37 dB. This residual reflection is adequate for making comparative measurements on planar absorber panels whose reflectivities usually fall in the -15 to -25 dB range. Reflectivity measurements on a variety of planar absorber panels show that multilayer Jaumann absorbers have the greatest inhomogeneity, while honeycomb absorbers generally have excellent homogeneity within a sheet and from sheet to sheet. The test setup is also used to measure the center frequencies of resonant absorbers. With directional couplers and aperture-matched exponential horns, the technique can be easily applied in the standard 2 to 40 GHz waveguide bands.

  4. Outcome of children older than one year with neuroblastoma.

    Science.gov (United States)

    Fayea, Najwa Y; Atra, Ayad A; Khattab, Taha; Elimam, Najla A; Felimban, Sami; Yousef, Abdelmoutaleb; Basheer, Ahmed; Zayed, Abdullah; Baothman, Abdullah; Al-Sheikh, Nada; Hussen, Wafa

    2008-01-01

    To assess the outcome of children older than one year with neuroblastoma treated at King Abdul-Aziz Medical City, Jeddah, Kingdom of Saudi Arabia. We retrospectively reviewed the files of 52 children older than one year with neuroblastoma (NBL) treated at our center between September 1987 and May 2003. Treatment consisted of OPEC chemotherapy regimen (vincristine, cisplatin, etoposide, and cyclophosphamide) or alternating OPEC/OJEC (carboplatin in place of cisplatin), surgical resection +/- radiotherapy (RT). No patient received high dose therapy (HDT). Thirty-four patients (65%) were stage 4, 12 (23%) stage 3, and 6 (11%) stage 2. Three stage 2 patients were treated with surgery only, all are alive in complete remission (CR). All stage 3 and 4 patients were treated with chemotherapy and surgery +/- RT. After induction chemotherapy, CR was achieved in 17 patients (32%) and partial remission in 10 (19%). Complete surgical resection was possible in 11 patients (22%). Disease recurrence or progression occurred in 27 patients (51%). With a median follow-up of 24 months (range 4-120), the 2-year event free survival was 10%, 82%, and 87% and the overall survival was 12%, 83%, and 100% for stage 4, 3, and 2. Children older than one year with localized NBL have good prognosis compared to those with stage 4. The use of HDT may improve the outcome in the latter group. Toxicity was significant, and adoption of risk-stratified treatment may help to reduce treatment complications.

  5. Neutron Absorbing Ability Variation in Neutron Absorbing Material Caused by the Neutron Irradiation in Spent Fuel Storage Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hee Dong; Han, Seul Gi; Lee, Sang Dong; Kim, Ki Hong; Ryu, Eag Hyang; Park, Hwa Gyu [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of)

    2014-10-15

    In spent fuel storage facility like high density spent fuel storage racks and dry storage casks, spent fuels are stored with neutron absorbing materials installed as a part of those facilities, and they are used for absorbing neutrons emitted from spent fuels. Usually structural material with neutron absorbing material of racks and casks are located around spent fuels, so it is irradiated by neutrons for long time. Neutron absorbing ability could be changed by the variation of nuclide composition in neutron absorbing material caused by the irradiation of neutrons. So, neutron absorbing materials are continuously faced with spent fuels with boric acid solution or inert gas environment. Major nuclides in neutron absorbing material are Al{sup 27}, C{sup 12}, B{sup 11}, B{sup 10} and they are changed to numerous other ones as radioactive decay or neutron absorption reaction. The B{sup 10} content in neutron absorbing material dominates the neutron absorbing ability, so, the variation of nuclide composition including the decrease of B{sup 10} content is the critical factor on neutron absorbing ability. In this study, neutron flux in spent fuel, the activation of neutron absorbing material and the variation of nuclide composition are calculated. And, the minimum neutron flux causing the decrease of B{sup 10} content is calculated in spent fuel storage facility. Finally, the variation of neutron multiplication factor is identified according to the one of B{sup 10} content in neutron absorbing material. The minimum neutron flux to impact the neutron absorbing ability is 10{sup 10} order, however, usual neutron flux from spent fuel is 10{sup 8} order. Therefore, even though neutron absorbing material is irradiated for over 40 years, B{sup 10} content is little decreased, so, initial neutron absorbing ability could be kept continuously.

  6. Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Onuma, Yoshinobu; Brugaletta, Salvatore

    2015-01-01

    Aims: The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with d...

  7. The predictive value of 2-year posttreatment biopsy after prostate cancer radiotherapy for eventual biochemical outcome

    International Nuclear Information System (INIS)

    Vance, Waseet; Tucker, Susan L.; Crevoisier, Renaud de; Kuban, Deborah A.; Cheung, M. Rex

    2007-01-01

    Purpose: To determine the value of a 2-year post-radiotherapy (RT) prostate biopsy for predicting eventual biochemical failure in patients who were treated for localized prostate cancer. Methods and Materials: This study comprised 164 patients who underwent a planned 2-year post-RT prostate biopsy. The independent prognostic value of the biopsy results for forecasting eventual biochemical outcome and overall survival was tested with other factors (the Gleason score, 1992 American Joint Committee on Cancer tumor stage, pretreatment prostate-specific antigen level, risk group, and RT dose) in a multivariate analysis. The current nadir + 2 (CN + 2) definition of biochemical failure was used. Patients with rising prostate-specific antigen (PSA) or suspicious digital rectal examination before the biopsy were excluded. Results: The biopsy results were normal in 78 patients, scant atypical and malignant cells in 30, carcinoma with treatment effect in 43, and carcinoma without treatment effect in 13. Using the CN + 2 definition, we found a significant association between biopsy results and eventual biochemical failure. We also found that the biopsy status provides predictive information independent of the PSA status at the time of biopsy. Conclusion: A 2-year post-RT prostate biopsy may be useful for forecasting CN + 2 biochemical failure. Posttreatment prostate biopsy may be useful for identifying patients for aggressive salvage therapy

  8. Aspheric photorefractive keratectomy for myopia and myopic astigmatism with the SCHWIND AMARIS laser: 2 years postoperative outcomes

    Science.gov (United States)

    Aslanides, Ioannis M.; Padroni, Sara; Arba-Mosquera, Samuel

    2012-01-01

    Purpose To evaluate mid-term refractive outcomes and higher order aberrations of aspheric PRK for low, moderate and high myopia and myopic astigmatism with the AMARIS excimer laser system (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). Methods This prospective longitudinal study evaluated 80 eyes of 40 subjects who underwent aspheric PRK. Manifest refractive spherical equivalent (MRSE) of up to −10.00 diopters (D) at the spectacle plane with cylinder up to 3.25 was treated. Refractive outcomes and corneal wavefront data (6 mm pupil to the 7th Zernike order) were evaluated out to 2 years postoperatively. Statistical significance was indicated by P  0.05, both cases). There was a statistical increase in postoperative coma (+0.12 μm) and spherical aberration (+0.14 μm) compared to preoperatively (P < 0.001, both cases). Conclusion Aspheric PRK provides excellent visual and refractive outcomes with induction in individual corneal aberrations but not overall corneal aberrations.

  9. Arthroscopic Labral Base Repair in the Hip: 5-Year Minimum Clinical Outcomes.

    Science.gov (United States)

    Domb, Benjamin G; Yuen, Leslie C; Ortiz-Declet, Victor; Litrenta, Jody; Perets, Itay; Chen, Austin W

    2017-10-01

    Arthroscopic labral base repair (LBR) in the hip is a previously described technique designed to restore the native functional anatomy of the labrum by reproducing its seal against the femoral head. LBR has been shown to have good short-term outcomes. Hypothesis/Purpose: The purpose was to evaluate clinical outcomes of an LBR cohort with a minimum 5-year follow-up. It was hypothesized that patients who underwent LBR would continue to have significant improvement from their preoperative scores and maintain scores similar to their 2-year outcomes. Case series; Level of evidence, 4. Data for patients undergoing primary hip arthroscopic surgery with LBR from February 2008 to May 2011 with a minimum 5-year follow-up were prospectively collected and retrospectively reviewed. Patients with preoperative Tonnis osteoarthritis grade ≥2, previous hip conditions (slipped capital femoral epiphysis, avascular necrosis, Legg-Calv-Perthes disease), severe dysplasia (lateral center-edge angle hip surgery were excluded. Statistical equivalence tests evaluated patient-reported outcomes (PROs) including the modified Harris Hip Score (mHHS), Non-Arthritic Hip Score (NAHS), Hip Outcome Score-Sport-Specific Subscale (HOS-SSS), visual analog scale (VAS) for pain, and patient satisfaction (0-10 scale; 10 = very satisfied). Of the 70 patients (74 hips) who met inclusion and exclusion criteria, 60 (85.7%) patients (64 hips) were available at a minimum 5-year follow-up. All PRO scores significantly improved from preoperative values with a mean follow-up of 67.8 ± 7.4 months (range, 60.0-89.7 months). The mean mHHS increased from 64.4 ±13.8 to 85.3 ± 17.7 ( P hip arthroscopic surgery has yet to be determined; however, these midterm results demonstrate the rates of additional procedures (both secondary arthroscopic surgery and conversion to total hip arthroplasty), that may be necessary after 2 years.

  10. ZED-2 experiments on the effect of a Co absorber rod on an NRU loop

    International Nuclear Information System (INIS)

    Arbique, G.M.; French, P.M.

    1983-02-01

    A series of experiments has been performed in ZED-2 to measure the perturbing effects of an NRU cobalt absorber rod on a simulated NRU loop site containing graded enrichment U0 2 fuel. The objective of the measurements was to provide data useful in validating NRU reactor physics codes. Using a simulated NRU lattice containing a simulated NRU loop site and an asymmetrically placed Co absorber rod, measurements were made of: (a) reactivity effects, as measured by critical height changes, associated with voiding the loop and stepped insertion of the Co absorber rod, (b) flux perturbations at the simulated loop site and throughout the lattice induced by the Co rod, (c) Westcott r√T/Tsub(o) values throughout the lattice

  11. Spectrally and spatially resolved photoluminescence. Lateral fluctuations and depth profiles of Cu(In,Ga)Se2-absorbers

    International Nuclear Information System (INIS)

    Neumann, Oliver

    2013-01-01

    The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se 2 .

  12. The 2-Year Cosmetic Outcome of a Randomized Trial Comparing Prone and Supine Whole-Breast Irradiation in Large-Breasted Women

    Energy Technology Data Exchange (ETDEWEB)

    Veldeman, Liv, E-mail: liv.veldeman@uzgent.be [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiotherapy and Experimental Cancer Research, Ghent University, Ghent (Belgium); Schiettecatte, Kimberly; De Sutter, Charlotte; Monten, Christel; Greveling, Annick van [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Berkovic, Patrick [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiation Oncology, Centre Hospitalier Universitaire de Liège, Liège (Belgium); Mulliez, Thomas [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); De Neve, Wilfried [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiotherapy and Experimental Cancer Research, Ghent University, Ghent (Belgium)

    2016-07-15

    Purpose: To report the 2-year cosmetic outcome of a randomized trial comparing prone and supine whole-breast irradiation in large-breasted patients. Methods and Materials: One hundred patients with a (European) cup size ≥C were included. Before and 2 years after radiation therapy, clinical endpoints were scored and digital photographs were taken with the arms alongside the body and with the arms elevated 180°. Three observers rated the photographs using the 4-point Harvard cosmesis scale. Cosmesis was also evaluated with the commercially available Breast Cancer Conservation Treatment.cosmetic results (BCCT.core) software. Results: Two-year follow-up data and photographs were available for 94 patients (47 supine treated and 47 prone treated). Patient and treatment characteristics were not significantly different between the 2 cohorts. A worsening of color change occurred more frequently in the supine than in the prone cohort (19/46 vs 10/46 patients, respectively, P=.04). Five patients in the prone group (11%) and 12 patients in the supine group (26%) presented with a worse scoring of edema at 2-year follow-up (P=.06). For retraction and fibrosis, no significant differences were found between the 2 cohorts, although scores were generally worse in the supine cohort. The cosmetic scoring by 3 observers did not reveal differences between the prone and supine groups. On the photographs with the hands up, 7 patients in the supine group versus none in the prone group had a worsening of cosmesis of 2 categories using the (BCCT.org) software (P=.02). Conclusion: With a limited follow-up of 2 years, better cosmetic outcome was observed in prone-treated than in supine-treated patients.

  13. Panchromatic response composed of hybrid visible-light absorbing polymers and near-IR absorbing dyes for nanocrystalline TiO{sub 2}-based solid-state solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyo Joong; Graetzel, Michael; Nazeeruddin, Md. Khaja [Laboratory for Photonics and Interfaces, Institute of Chemical Sciences and Engineering, School of Basic Sciences, Swiss Federal Institute of Technology, CH-1015 Lausanne (Switzerland); Leventis, Henry C.; Haque, Saif A. [Department of Chemistry, Imperial College of Science Technology and Medicine, London SW72AZ (United Kingdom); Torres, Tomas [Departamento de Quimica Organica, Universidad Autonoma de Madrid (UAM), 28049 Madrid (Spain)

    2011-01-01

    In pursuit of panchromatic sensitizers for mesoporous TiO{sub 2}-based solid-state solar cells, a near-IR absorbing zinc phthalocyanine dye (coded TT1) was firstly adsorbed over relatively thin ({proportional_to}1 {mu}m) TiO{sub 2} mesoporous films and then a visible-light absorbing polymer [regioregular poly(3-hexylthiophene), P3HT] was incorporated into the mesopores as both a second sensitizer and a solid hole conductor. After optimizing some experimental parameters, these hybrid solid-state cells exhibited a clear panchromatic response, and an overall conversion efficiency of around 1% at full sun intensity. (author)

  14. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  15. Shock absorber in Ignalina NPP

    International Nuclear Information System (INIS)

    Bulavas, A.; Muralis, J.

    1996-09-01

    Theoretical calculation and experimental analysis of models of shock absorber in Ignalina NPP is presented. The results obtained from the investigation with model of shock absorber coincide with the theoretical calculation. (author). 2 figs., 3 refs

  16. The Ahmed Versus Baerveldt study: one-year treatment outcomes.

    Science.gov (United States)

    Christakis, Panos G; Kalenak, Jeffrey W; Zurakowski, David; Tsai, James C; Kammer, Jeffrey A; Harasymowycz, Paul J; Ahmed, Iqbal I K

    2011-11-01

    To report the 1-year treatment outcomes of the Ahmed Versus Baerveldt (AVB) Study. Multicenter randomized clinical trial. A total of 238 patients were enrolled in the study, including 124 in the Ahmed group and 114 in the Baerveldt group. Patients aged 18 years or older with uncontrolled glaucoma refractory to medicinal, laser, and surgical therapy were randomized to undergo implantation of an Ahmed-FP7 valve (New World Medical, Inc., Rancho Cucamonga, CA) or a Baerveldt-350 implant (Abbott Medical Optics, Inc., Santa Ana, CA), to be followed for 5 years. The primary outcome measure was failure, defined as intraocular pressure (IOP) out of target range (5-18 mmHg with ≥ 20% reduction from baseline) for 2 consecutive visits after 3 months, vision-threatening complications, additional glaucoma procedures, or loss of light perception. Secondary outcome measures included IOP, medication use, visual acuity, complications, and interventions. There were no significant differences in baseline ocular or demographic characteristics between the study groups with the exception of sex. Preoperatively, the study group had a mean IOP of 31.4 ± 10.8 mmHg on a mean of 3.1 ± 1.0 glaucoma medications with a median Snellen acuity of 20/100. The cumulative probability of failure a 1-year was 43% in the Ahmed group and 28% in the Baerveldt group (P = 0.02). The mean IOP at 1 year was 16.5 ± 5.3 mmHg in the Ahmed group and 13.6 ± 4.8 mmHg in the Baerveldt group (P glaucoma medications required was 1.6 ± 1.3 in the Ahmed group and 1.2 ± 1.3 in the Baerveldt group (P = 0.03). Visual acuity was similar in both groups at all visits in the first year (P = 0.66). In the first year after surgery, there were a similar number of patients who experienced postoperative complications in the 2 groups (45% Ahmed, 54% Baerveldt, P = 0.19), but a greater number of patients in the Baerveldt group required interventions (26% Ahmed vs. 42% Baerveldt, P = 0.009). The Baerveldt-350 group had a higher

  17. Preparation of Active Absorbent for Flue Gas Desulfurization From Coal Bottom Ash: Effect of Absorbent Preparation Variables

    Directory of Open Access Journals (Sweden)

    Chang Chin Li, Lee Keat Teong, Subhash Bhatia and Abdul Rahman Mohamed

    2012-08-01

    Full Text Available An active absorbent for flue gas desulfurization was prepared from coal bottom ash, calcium oxide (CaO and calcium sulfate by hydro-thermal process. The absorbent was examined for its micro-structural properties. The experiments conducted were based on Design Of Experiments (DOE according to 23 factorial design. The effect of various absorbent preparation variables such as ratio of CaO to bottom ash (A, hydration temperature (B and hydration period (C towards the BET (Brunauer-Emmett-Teller specific surface area of the absorbent were studied. At a CaO to bottom ash ratio = 2, hydration temperature = 200 ?C and hydration period = 10 hrs, absorbent with a surface area of 90.1 m2/g was obtained. Based on the analysis of the factorial design, it was concluded that factor A and C as well as the interaction of factors ABC and BC are the significant factors that effect the BET surface area of the absorbent. A linear mathematical model that describes the relation between the independent variables and interaction between variables towards the BET specific surface area of the absorbent was also developed. Analysis of variance (ANOVA showed that the model was significant at 1% level.Key Words: Absorbent, Bottom Ash, Design Of Experiments, Desulfurization, Surface Area.

  18. 360-degree suture trabeculotomy ab interno to treat open-angle glaucoma: 2-year outcomes

    Science.gov (United States)

    Sato, Tomoki; Kawaji, Takahiro; Hirata, Akira; Mizoguchi, Takanori

    2018-01-01

    Purpose The purpose of this study was to evaluate the efficacy of 360-degree suture trabeculotomy (360S-LOT) ab interno for treating open-angle glaucoma (OAG). Risk factors of surgical failure were examined. Patients and methods 360S-LOT ab interno alone was performed for patients with uncontrolled OAG, and combined 360S-LOT ab interno/phacoemulsification was performed for patients with controlled OAG with a visually significant cataract between March 2014 and September 2015 at a single center. The patients were prospectively followed for 2 years. The main outcome measures included 2-year intraocular pressure (IOP), number of anti-glaucoma medications used, postoperative complications, and predictive factors of surgical failure. Kaplan–Meier analysis was performed, with surgical success (with or without medication use) defined as postoperative IOP ≤15 mmHg and IOP reduction ≥20% (criterion A) or IOP ≤12 mmHg and IOP reduction ≥30% (criterion B). Predictive factors were evaluated using Cox proportional hazard ratios. Results A total of 64 eyes of 64 patients were included, and 50 (78%) eyes of 64 eyes underwent a phacoemulsification combination procedure. Surgery significantly reduced IOP from 18.4 ± 2.9 mmHg before surgery to 13.4 ± 3.0 mmHg after surgery (P interno procedure is a favorable option for treating eyes with mild or moderate OAG. PMID:29844656

  19. Do illness perceptions predict health outcomes in primary care patients? A 2-year follow-up study

    DEFF Research Database (Denmark)

    Frostholm, Lisbeth; Ørnbøl, Eva; Christensen, Kaj Aage Sparle

    2007-01-01

    OBJECTIVE: Little is known about whether illness perceptions affect health outcomes in primary care patients. The aim of this study was to examine if patients' illness perceptions were associated with their self-rated health in a 2-year follow-up period. METHODS: One thousand seven hundred eighty...... at follow-up for the whole group of patients. Patients presenting with MUS had more negative illness perceptions and lower mental and physical components subscale of the SF-36 scores at all time points. CONCLUSIONS: Patients' perception of a new or recurrent health problem predicts self-reported physical......-five primary care patients presenting a new or recurrent health problem completed an adapted version of the illness perception questionnaire and the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36) at baseline and 3, 12, and 24 months' follow-up. Linear regressions were performed for (1) all...

  20. Shock absorber

    International Nuclear Information System (INIS)

    Housman, J.J.

    1978-01-01

    A shock absorber is described for use in a hostile environment at the end of a blind passage for absorbing impact loads. The shock absorber includes at least one element which occupies the passage and which is comprised of a porous brittle material which is substantially non-degradable in the hostile environment. A void volume is provided in the element to enable the element to absorb a predetermined level of energy upon being crushed due to impact loading

  1. Actual behaviour of a ball vibration absorber

    Czech Academy of Sciences Publication Activity Database

    Pirner, Miroš

    2002-01-01

    Roč. 90, č. 8 (2002), s. 987-1005 ISSN 0167-6105 R&D Projects: GA ČR(CZ) GV103/96/K034 Institutional support: RVO:68378297 Keywords : TV towers * wind-excited vibrations * vibration absorbers * pendulum absorber Subject RIV: JM - Building Engineering Impact factor: 0.513, year: 2002 http://www.sciencedirect.com/science/article/pii/S0167610502002155#

  2. Neurodevelopmental outcome at 2 years in twin-twin transfusion syndrome survivors randomized for the Solomon trial.

    Science.gov (United States)

    van Klink, Jeanine M M; Slaghekke, Femke; Balestriero, Marina A; Scelsa, Barbara; Introvini, Paola; Rustico, Mariangela; Faiola, Stefano; Rijken, Monique; Koopman, Hendrik M; Middeldorp, Johanna M; Oepkes, Dick; Lopriore, Enrico

    2016-01-01

    The preferred treatment for twin-twin transfusion syndrome is fetoscopic laser coagulation of inter-twin vascular anastomoses on the monochorionic placenta. Severe postoperative complications can occur when inter-twin vascular anastomoses remain patent including twin-anemia polycythemia sequence or recurrent twin-twin transfusion syndrome. To minimize the occurrence of residual anastomoses, a modified laser surgery technique, the Solomon technique, was developed in which the entire vascular equator is coagulated. In the Solomon randomized controlled trial (NTR1245), the Solomon technique was associated with a significant reduction in twin-anemia polycythemia sequence and recurrence of twin-twin transfusion syndrome when compared with the standard laser surgery technique. Although a significant improvement in perinatal outcome was shown after the Solomon technique, the clinical importance should also be ascertained with long-term follow-up evaluation of the surviving children. The purpose of this study was to compare the long-term neurodevelopmental outcome in surviving children with twin-twin transfusion syndrome who were included in the Solomon randomized trial and treated with either the Solomon technique or standard laser surgery technique. Routine standardized follow-up evaluation in survivors, at least 2 years after the estimated date of delivery, was performed at 2 of the 5 centers that participated in the Solomon trial: Buzzi Hospital Milan (Italy) and Leiden University Medical Center (The Netherlands). The primary outcome of this follow-up study was survival without long-term neurodevelopmental impairment at age 2 years. Neurodevelopmental impairment was defined as cerebral palsy, cognitive and/or motor development score of neurodevelopmental impairment) was detected in 95 of 141 cases (67%) in the Solomon group and in 99 of 146 cases (68%) in the standard group (P = .92). Neurodevelopmental impairment in long-term survivors who were included for follow

  3. Nitrile-functionalized tertiary amines as highly efficient and reversible SO2 absorbents

    International Nuclear Information System (INIS)

    Hong, Sung Yun; Kim, Heehwan; Kim, Young Jin; Jeong, Junkyo; Cheong, Minserk; Lee, Hyunjoo; Kim, Hoon Sik; Lee, Je Seung

    2014-01-01

    Highlights: • Nitrile-functionalized tertiary amines physically and reversibly absorb SO 2 . • Tertiary alkanolamines chemically and irreversibly absorb SO 2 through OH group. • SO 2 absorption modes were studied by spectroscopy and computational calculations. -- Abstract: Three different types of nitrile-functionalized amines, including 3-(N,N-diethylamino)propionitrile (DEAPN), 3-(N,N-dibutylamino)propionitrile (DBAPN), and N-methyl-N,N-dipropionitrile amine (MADPN) were synthesized, and their SO 2 absorption performances were evaluated and compared with those of hydroxy-functionalized amines such as N,N-diethyl-N-ethanol amine (DEEA), N,N-dibutyl-N-ethanol amine (DBEA), and N-methyl-N,N-diethanol amine (MDEA). Absorption–desorption cycle experiments clearly demonstrate that the nitrile-functionalized amines are more efficient than the hydroxy-functionalized amines in terms of absorption rate and regenerability. Computational calculations with DBEA and DBAPN revealed that DBEA bearing a hydroxyethyl group chemically interacts with SO 2 through oxygen atom, forming an ionic compound with a covalently bound -OSO 2 − group. On the contrary, DBAPN bearing a nitrile group physically interacts with SO 2 through the nitrogen and the hydrogen atoms of the two methylene groups adjacent to the amino and nitrile functionalities

  4. Dialectical behavior therapy compared with general psychiatric management for borderline personality disorder: clinical outcomes and functioning over a 2-year follow-up.

    Science.gov (United States)

    McMain, Shelley F; Guimond, Tim; Streiner, David L; Cardish, Robert J; Links, Paul S

    2012-06-01

    The authors conducted a 2-year prospective naturalistic follow-up study to evaluate posttreatment clinical outcomes in outpatients who were randomly selected to receive 1 year of either dialectical behavior therapy or general psychiatric management for borderline personality disorder. Patients were assessed by blind raters 6, 12, 18, and 24 months after treatment. The clinical effectiveness of treatment was assessed on measures of suicidal and nonsuicidal self-injurious behaviors, health care utilization, general symptom distress, depression, anger, quality of life, social adjustment, borderline psychopathology, and diagnostic status. The authors conducted between-group comparisons using generalized estimating equation, mixed-effects models, or chi-square statistics, depending on the distribution and nature of the data. Both treatment groups showed similar and statistically significant improvements on the majority of outcomes 2 years after discharge. The original effects of treatment did not diminish for any outcome domain, including suicidal and nonsuicidal self-injurious behaviors. Further improvements were seen on measures of depression, interpersonal functioning, and anger. However, even though two-thirds of the participants achieved diagnostic remission and significant increases in quality of life, 53% were neither employed nor in school, and 39% were receiving psychiatric disability support after 36 months. One year of either dialectical behavior therapy or general psychiatric management was associated with long-lasting positive effects across a broad range of outcomes. Despite the benefits of these specific treatments, one important finding that replicates previous research is that participants continued to exhibit high levels of functional impairment. The effectiveness of adjunctive rehabilitation strategies to improve general functioning deserves additional study.

  5. The Test of Infant Motor Performance at 3 months predicts language, cognitive, and motor outcomes in infants born preterm at 2 years of age.

    Science.gov (United States)

    Peyton, Colleen; Schreiber, Michael D; Msall, Michael E

    2018-03-13

    To determine the relationship between the Test of Infant Motor Performance (TIMP) at 3 months and cognitive, language, and motor outcomes on the Bayley Scales of Infant and Toddler Development, Third Edition (Bayley-III) at 2 years of age in high-risk infants born preterm. One hundred and six infants (47 females, 59 males) born at earlier than 31 weeks gestational age were prospectively tested with the TIMP at 10 to 15 weeks after term age and were assessed again with the Bayley-III at 2 years corrected age. Sensitivity and specificity were calculated for various cut points of the TIMP z-score and Bayley-III composite scores of no more than 85. The TIMP z-scores at 10 to 15 weeks of age were significantly associated with all three subscales on the Bayley-III at 2 years of age (pcognitive (87%), language (88%), and motor (89%) outcomes, but sensitivity was low (cognitive 41%, language 49%, motor 57%). This study demonstrates that the TIMP is related to cognitive, language, and motor outcomes on the Bayley-III at 2 years of age in high-risk infants born preterm. The Test of Infant Motor Performance (TIMP) predicts Bayley Scales of Infant and Toddler Development, Third Edition outcomes at 2 years of age. The TIMP is relatively good at discriminating between children who will and will not have typical development. © 2018 Mac Keith Press.

  6. Shock absorbing structure

    International Nuclear Information System (INIS)

    Kojima, Naoki; Matsushita, Kazuo.

    1992-01-01

    Small pieces of shock absorbers are filled in a space of a shock absorbing vessel which is divided into a plurality of sections by partitioning members. These sections function to prevent excess deformation or replacement of the fillers upon occurrence of falling accident. Since the shock absorbing small pieces in the shock absorbing vessel are filled irregularly, shock absorbing characteristics such as compression strength is not varied depending on the direction, but they exhibit excellent shock absorbing performance. They surely absorb shocks exerted on a transportation vessel upon falling or the like. If existing artificial fillers such as pole rings made of metal or ceramic and cut pieces such as alumium extrusion molding products are used as the shock absorbing pieces, they have excellent fire-proofness and cold resistance since the small pieces are inflammable and do not contain water. (T.M.)

  7. COMPARISON OF ABSORBABLE EXTRA LONG TERM POLY HYDROXY BUTYRATE SUTURE VS NON ABSORBABLE (POLYPROPYLENE SUTURE FOR ABDOMINAL WALL CLOSURE

    Directory of Open Access Journals (Sweden)

    Mallikarjun

    2015-07-01

    Full Text Available PURPOSE: The aim of study is to compare Continuous technique with non - absorbable sutures, Interrupted technique with non - absorbable sutures and Continuous technique with slowly absorbable sutures Focusing mainly on incidence of incisional hernias, burst abdomen, wound infections, chronic wound pain, suture sinus, stitch granuloma, time for rectus closure. METHODOLOGY : Study was conducted for a period of one year on 271 randomized patients with primary elective midline laparotomy in our hospital . patients are divided into group I includes 102 patients with continuous technique using non absorbable polypropylene, group II includes 91 patients with interrupted technique using non absorbable polypropylene and group III includes 78 patients with continuous slowly absorbable polyhydroxybutyrate. RESULTS: No significant difference observed in incidence of wound infections and burst abdomen in all the 3 groups but relatively higher incidence of wound infections in noted our hospital. Incidence of stich granuloma suture sinus and chronic wound pain is more with interrupted technique than continuous technique and are more with non - absor bable suture material. CONCLUSION: Incidence of incisional hernias, suture complications like suture sinus, stitch granuloma can be more effectively reduced with slowly absorbable continuous sutures.

  8. Microcytosis is associated with low cognitive outcomes in healthy 2-year-olds in a high-resource setting.

    Science.gov (United States)

    McCarthy, Elaine K; Kiely, Mairead E; Hannon, Geraldine; Ahearne, Caroline; Kenny, Louise C; Hourihane, Jonathan O'B; Irvine, Alan D; Murray, Deirdre M

    2017-09-01

    Fe deficiency in early childhood is associated with long-term consequences for cognitive, motor and behavioural development; however explorations in healthy children from low risk, high-resource settings have been limited. We aimed to explore associations between Fe status and neurodevelopmental outcomes in low risk, healthy 2-year-olds. This study was a secondary analysis of a nested case-control subgroup from the prospective, maternal-infant Cork Babies after Screening for Pregnancy Endpoints: Evaluating the Longitudinal Impact using Neurological and Nutritional Endpoints (BASELINE) Birth Cohort Study. At 2 years, serum ferritin, Hb and mean corpuscular volume (MCV) were measured and neurodevelopment was assessed using the Bayley Scales of Infant and Toddler Development (n 87). Five children had Fe deficiency (ferritin cognitive composite scores (88·5 (sd 13·3) v. 97·0 (sd 7·8), P=0·04, Cohen's d effect size=0·8) than those without microcytosis. The ferritin concentration which best predicted microcytosis was calculated as 18·4 µg/l (AUC=0·87 (95% CI 0·75, 0·98), Pcognitive composite scores (92·3 (sd 10·5) v. 97·8 (sd 8·1), P=0·012, Cohen's d effect size=0·6) compared with those with ferritin ≥18·5 µg/l. All associations were robust after adjustment for potential confounding factors. Despite a low prevalence of Fe deficiency using current diagnostic criteria in this healthy cohort, microcytosis was associated with lower cognitive outcomes at 2 years. This exploratory study emphasises the need for re-evaluation of the diagnostic criteria for Fe deficiency in young children, with further research in adequately powered studies warranted.

  9. The role of youth mental health services in the treatment of young people with serious mental illness: 2-year outcomes and economic implications.

    Science.gov (United States)

    Brimblecombe, Nicola; Knapp, Martin; Murguia, Silvia; Mbeah-Bankas, Henrietta; Crane, Steve; Harris, Abi; Evans-Lacko, Sara; Ardino, Vittoria; Iemmi, Valentina; King, Derek

    2017-10-01

    This study aims to evaluate the outcomes and economic case for a UK innovative youth-specific mental health service for 16-25 year olds. A pre-, during- and post-treatment comparative design for 20 young people at high risk of developing psychosis who received 2 years' treatment with the service, using outcomes that concurred with the service aims: changes in mental health, employment rates and service use. Forty-five percent of those at risk and with symptoms of serious mental illness commencing treatment were not receiving mental health services at baseline. Compared with service use prior to treatment at the youth-specific service, hospital admissions, Accident and Emergency, and criminal justice system use appear to decrease over the 2 years of treatment and the year after treatment, with potential cost differences of £473 000. Mental health improved or stayed the same, compared with baseline. Employment rates improved, although the sample size for this is very small. Potential cost differences associated with service users moving into employment over the 2 years are £148 000. The estimated cost over 2 years of providing the youth-specific mental health service to these young people was £106 000. Given the extensive long-term negative consequences and high costs of untreated mental illness in the 16-25 age group and the documented problems young people have in receiving appropriate services, this youth-specific, age-appropriate service model appears to be successful, with improved outcomes and cost differences in the short-term, and with encouraging implications for the longer term. © 2015 Wiley Publishing Asia Pty Ltd.

  10. Social-ecological resources as mediators of two-year diet and physical activity outcomes in type 2 diabetes patients.

    Science.gov (United States)

    Barrera, Manuel; Strycker, Lisa A; Mackinnon, David P; Toobert, Deborah J

    2008-03-01

    In behavioral research directed at the treatment of type 2 diabetes, the challenge is to understand how interventions might facilitate long-term lifestyle changes. The Mediterranean Lifestyle Program (MLP) is an intervention for postmenopausal women diagnosed with type 2 diabetes that has shown promising effects on outcomes that include increased physical activity and reduced fat consumption. The present study extended previous findings by evaluating diet-specific and activity-specific social-ecological resources as possible mediators of intervention effects over a 2-year period. Percent calories from saturated fat and caloric expenditure per week in all physical activities were assessed with self-report questionnaires. The MLP was successful in increasing participants' use of diet-specific and activity-specific family/friend and neighborhood resources. There was some evidence that changes in those resources mediated intervention effects on saturated fat consumption and physical activity outcomes. The experimental manipulation of mediators and the demonstrated mediational effects provided some support for the conclusion that social-ecological resources can contribute to improvements in healthful lifestyles for women with type 2 diabetes. (c) 2008 APA, all rights reserved

  11. Association between breakfast consumption and educational outcomes in 9?11-year-old children

    OpenAIRE

    Littlecott, Hannah J; Moore, Graham F; Moore, Laurence; Lyons, Ronan A; Murphy, Simon

    2015-01-01

    Objective Breakfast consumption has been consistently associated with health outcomes and cognitive functioning in schoolchildren. Evidence of direct links with educational outcomes remains equivocal. We aimed to examine the link between breakfast consumption in 9–11-year-old children and educational outcomes obtained 6–18 months later.\\ud Design Data on individual-level free school meal entitlement and educational outcomes (Statutory Assessment Tests (SATs) at Key Stage 2) were obtained via ...

  12. Does Treatment of the Tibia Matter in Bipolar Chondral Defects of the Knee? Clinical Outcomes with Greater Than 2 Years Follow-up.

    Science.gov (United States)

    Hannon, Charles P; Weber, Alexander E; Gitelis, Matthew; Meyer, Maximillian A; Yanke, Adam B; Cole, Brian J

    2018-04-01

    To compare the osteochondral allograft (OCA) outcomes of bipolar defects with isolated femoral defects and to investigate the optimal treatment of bipolar defects by comparing femoral OCA with tibial debridement to femoral OCA and tibial microfracture. A series of patients with 2-year follow-up from March 2004 to September 2015 after femoral OCA for bipolar chondral defects was identified. Group 1 contained patients with tibial defects treated with debridement and group 2 contained patients with microfractured tibial defects. A third group (group 3) with isolated femoral defects treated with OCA was identified and matched by gender, body mass index (BMI), laterality, and OCA size to groups 1 and 2. Patient-specific, defect-specific, intraoperative, and postoperative data including patient-reported outcomes were collected on all patients. The study groups were compared using analyses of variance, paired sample t tests, and χ-square analyses. Thirty-six patients who had femoral OCA for bipolar lesions were identified with 20 patients in group 1 and 16 patients in group 2. Group 3 had 20 patients. There were no differences between the 3 groups in terms of gender (P = .616), BMI (P = .271), number of previous surgeries (P = .451), femoral or tibial defect size (P = .296), and OCA size (P = .981). Preoperative to postoperative patient-reported clinical outcomes (PROs) revealed statistical and clinically meaningful improvement in all 3 groups, but did not differ between groups. Patient-specific and defect-specific factors did not correlate with PROs. The graft survivorship for group 1 was 85% at 4.5 years, 100% for group 2 at 2.5 years, and 95% for group 3 at 3.8 years. Regardless of tibial treatment, patients with bipolar defects treated with femoral OCA have clinically meaningful improvements in PROs and excellent graft survivorship comparable to isolated femoral OCAs at more than 2 years. Level III, case-control study. Copyright © 2017 Arthroscopy

  13. Performance of a new carbon dioxide absorbent, Yabashi lime® as compared to conventional carbon dioxide absorbent during sevoflurane anesthesia in dogs.

    Science.gov (United States)

    Kondoh, Kei; Atiba, Ayman; Nagase, Kiyoshi; Ogawa, Shizuko; Miwa, Takashi; Katsumata, Teruya; Ueno, Hiroshi; Uzuka, Yuji

    2015-08-01

    In the present study, we compare a new carbon dioxide (CO2) absorbent, Yabashi lime(®) with a conventional CO2 absorbent, Sodasorb(®) as a control CO2 absorbent for Compound A (CA) and Carbon monoxide (CO) productions. Four dogs were anesthetized with sevoflurane. Each dog was anesthetized with four preparations, Yabashi lime(®) with high or low-flow rate of oxygen and control CO2 absorbent with high or low-flow rate. CA and CO concentrations in the anesthetic circuit, canister temperature and carbooxyhemoglobin (COHb) concentration in the blood were measured. Yabashi lime(®) did not produce CA. Control CO2 absorbent generated CA, and its concentration was significantly higher in low-flow rate than a high-flow rate. CO was generated only in low-flow rate groups, but there was no significance between Yabashi lime(®) groups and control CO2 absorbent groups. However, the CO concentration in the circuit could not be detected (≤5ppm), and no change was found in COHb level. Canister temperature was significantly higher in low-flow rate groups than high-flow rate groups. Furthermore, in low-flow rate groups, the lower layer of canister temperature in control CO2 absorbent group was significantly higher than Yabashi lime(®) group. CA and CO productions are thought to be related to the composition of CO2 absorbent, flow rate and canister temperature. Though CO concentration is equal, it might be safer to use Yabashi lime(®) with sevoflurane anesthesia in dogs than conventional CO2 absorbent at the point of CA production.

  14. Studies of calorimeter absorbers for CW and pulsed CO2 lasers

    International Nuclear Information System (INIS)

    Gunn, S.R.

    1975-01-01

    Solid and liquid absorbers, used in calorimeters to measure the power and energy of cw and pulsed CO 2 lasers, have been studied from 9.24 to 10.76 μm (cw) and near 10.588 μm (pulsed). The principal materials used were magnesium oxide, lithium fluoride, polystyrene, polytetrafluorethylene, carbon tetrachloride and kerosene. (U.S.)

  15. Bilateral Moyamoya Disease in a 2-Year-Old Pakistani Male Treated with Bilateral Encephaloduroarteriosynangiosis: A Positive Outcome

    Directory of Open Access Journals (Sweden)

    Shahvaiz Magsi

    2016-01-01

    Full Text Available Background. We present a rare case of bilateral moyamoya disease presenting as multiple strokes and neurological deficits, treated with the neurosurgical procedure, encephaloduroarteriosynangiosis (EDAS, in a 2-year-old male Pakistani minor. A positive outcome was achieved and the patient recovered fully. Case Summary. Our patient presented with a history of seizures and multiple episodes of hemiparesis (on and off weakness at the age of 2 years. He had a delayed speech development and could not speak more than a few words. He had a slight slurring of speech too. He was diagnosed with bilateral moyamoya disease on Computed Tomography Angiography (CTA. Bilateral EDAS was done in the same year, after which his symptoms improved and patient had moderate functional recovery. Conclusion. A rare disease, moyamoya has been left unexplored in Pakistan; physicians and surgeons when dealing with cases in the pediatric population presenting with symptoms of stroke, signs of generalized weakness, and seizures should consider moyamoya disease as a possibility. Furthermore, this case demonstrates the effectiveness of EDAS procedure for the treatment of moyamoya disease.

  16. Neutron physics calculation for WWER-1000 absorber element lifetime determination

    International Nuclear Information System (INIS)

    Kurakin, K.Yu.; Kushmanov, S.A.

    2009-01-01

    Absorber element with compound absorber has been operating in WWER-1000 power units since 1995. AE design meets operating organizations requirements for reliability, service life (to 10 years) and safety functions. Extension of AE service life up to 20 - 30 years by the complex of calculation and experimental work is an important problem of WWER new designs development. The paper deals with the issues related to calculation determination of main factors that influence AE service life limitation - neutron flux and fluence onto absorbing and structural materials during extended service life. (Authors)

  17. Designing a hand rest tremor dynamic vibration absorber using H{sub 2} optimization method

    Energy Technology Data Exchange (ETDEWEB)

    Rahnavard, Mostafa; Dizaji, Ahmad F. [Tehran University, Tehran (Iran, Islamic Republic of); Hashemi, Mojtaba [Amirkabir University, Tehran (Iran, Islamic Republic of); Faramand, Farzam [Sharif University, Tehran (Iran, Islamic Republic of)

    2014-05-15

    An optimal single DOF dynamic absorber is presented. A tremor has a random nature and then the system is subjected to a random excitation instead of a sinusoidal one; so the H{sub 2} optimization criterion is probably more desirable than the popular H{sub ∞} optimization method and was implemented in this research. The objective of H{sub 2} optimization criterion is to reduce the total vibration energy of the system for overall frequencies. An objective function, considering the elbow joint angle, θ {sub 2}, tremor suppression as the main goal, was selected. The optimization was done by minimization of this objective function. The optimal system, including the absorber, performance was analyzed in both time and frequency domains. Implementing the optimal absorber, the frequency response amplitude of θ{sub 2} was reduced by more than 98% and 80% at the first and second natural frequencies of the primary system, respectively. A reduction of more than 94% and 78%, was observed for the shoulder joint angle, θ{sub 1}. The objective function also decreased by more than 46%. Then, two types of random inputs were considered. For the first type, θ{sub 1} and θ {sub 2} revealed 60% and 39% reduction in their rms values, whereas for the second type, 33% and 50% decrease was observed.

  18. LBNF Hadron Absorber: Mechanical Design and Analysis for 2.4MW Operation

    Energy Technology Data Exchange (ETDEWEB)

    Hartsell, B. [Fermilab; Anderson, K. [Fermilab; Hylen, J. [Fermilab; Sidorov, V. [Fermilab; Tariq, S. [Fermilab

    2015-06-01

    Fermilab’s Long-Baseline Neutrino Facility (LBNF) requires an absorber, essentially a large beam dump consisting of actively cooled aluminum and steel blocks, at the end of the decay pipe to stop leftover beam particles and provide radiation protection to people and groundwater. At LBNF’s final beam power of 2.4 MW and assuming the worst case condition of a 204 m long helium filled decay pipe, the absorber is required to handle a heat load of about 750 kW. This results in significant thermal management challenges which have been mitigated by the addition of an aluminum ‘spoiler’ and ‘sculpting’ the central portion of the aluminum core blocks. These thermal effects induce structural stresses which can lead to fatigue and creep considerations. Various accident conditions are considered and safety systems are planned to monitor operation and any accident pulses. Results from these thermal and structural analyses will be presented as well as the mechanical design of the absorber. The design allows each of the core blocks to be remotely removed and replaced if necessary. A shielded remote handling structure is incorporated to hold the hadron monitor when it is removed from the beam.

  19. X-ray Luminosity and Absorption Column Fluctuations in the H2O Maser Galaxy NGC 4258 from Weeks to Years

    International Nuclear Information System (INIS)

    Argon, A.

    2004-01-01

    The authors report monitoring of the 0.3-10 keV spectrum of NGC 4258 with the XMM-Newton observatory at five epochs over 1.5 years. They also report reprocessing of an overlapping four epoch series of archival Chandra observations (0.5-10 keV). By including earlier ASCA and Beppo-SAX observations, they present a new, nine year time-series of models fit to the X-ray spectrum of NGC 4258. They model the Chandra and XMM-Newton data self-consistently with partially absorbed, hard power-law, soft thermal plasma, and soft power-law components. Over the nine years, the photo-electric absorbing column (∼ 10 23 cm -2 ) did not vary detectably, except for a ∼ 40% drop between two ASCA epochs separated by 3 years (in 1993 and 1996) and a ∼ 60% rise between two XMM-Newton epochs separated by just 5 months (in 2001 and 2002). In contrast, factor of 2-3 changes are seen in absorbed flux on the timescale of years. These are uncorrelated with changes in absorbing column and indicative of central engine variability. The most rapid change in luminosity (5-10 keV) that the authors detect (with XMM-Newton and Chandra) is on the order of 30% over 19 days. The warped disk that is a known source of H 2 O maser emission in NGC 4258 is believed to cross the line of sight to the central engine. They propose that the variations in absorbing column arise from inhomogeneities in the rotating disk, as they sweep across the line of sight. They estimate that the inhomogeneities are ∼ 10 15 cm in size

  20. Absorbing Property of Multi-layered Short Carbon Fiber Absorbing Coating

    OpenAIRE

    Liu, Zhaohui; Tao, Rui; Ban, Guodong; Luo, Ping

    2018-01-01

    The radar absorbing coating was prepared with short carbon fiber asabsorbent and waterborne polyurethane (WPU) as matrix resin. The coating’s absorbing property was tested with vectornetwork analyzer, using aramid honeycomb as air layer which was matched withcarbon fiber coating. The results demonstrate that the single-layered carbonfiber absorbing coating presented relatively poor absorbing property when thelayer was thin, and the performance was slightly improved after the matched airlayer ...

  1. Simulation of a silicon neutron detector coated with TiB2 absorber

    International Nuclear Information System (INIS)

    Krapohl, D; Nilsson, H-E; Petersson, S; Slavicek, T; Thungström, G; Pospisil, S

    2012-01-01

    Neutron radiation cannot be directly detected in semiconductor detectors and therefore needs converter layers. Planar clean-room processing can be used in the manufacturing process of semiconductor detectors with metal layers to produce a cost-effective device. We used the Geant4 Monte-Carlo toolkit to simulate the performance of a semiconductor neutron detector. A silicon photo-diode was coated with vapour deposited titanium, aluminium thin films and a titaniumdiboride (TiB 2 ) neutron absorber layer. The neutron capture reaction 10B(n, alpha)7Li is taken advantage of to create charged particles that can be counted. Boron-10 has a natural abundance of about SI 19.8%. The emitted alpha particles are absorbed in the underlying silicon detector. We varied the thickness of the converter layer and ran the simulation with a thermal neutron source in order to find the best efficiency of the TiB 2 converter layer and optimize the clean room process.

  2. 17-year outcome of preterm infants with diverse neonatal morbidities: part 2, impact on activities and participation.

    Science.gov (United States)

    Sullivan, Mary C; Miller, Robin J; Msall, Michael E

    2012-10-01

    To examine functioning and participation in a diverse U.S. sample of 180 infants at age 17 years. The World Health Organization International Classification of Functioning, Disability and Health model framed functioning and participation domains and contextual factors. Assessment included cognition, executive functioning, academic achievement, personal functioning, community participation, and social involvement. Socioeconomic status, not prematurity, impacted cognitive and academic outcomes. Across neonatal morbidities, male gender and social disadvantage are key determinants of cognitive, academic, and social functioning. Interventions addressing academic and social-behavioral competencies in early school years may potentially optimize long-term preterm outcomes. © 2012, Wiley Periodicals, Inc.

  3. Microwave absorbing property of a hybrid absorbent with carbonyl irons coating on the graphite

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yonggang, E-mail: xuyonggang221@163.com [Science and Technology on Electromagnetic Scattering Laboratory, Shanghai, 200438 (China); Yan, Zhenqiang; Zhang, Deyuan [Bionic and Micro/Nano/Bio Manufacturing Technology Research Center, School of Mechanical Engineering and Automation, Beihang University, Beijing 100191 (China)

    2015-11-30

    Graphical abstract: The absorbing property could be enhanced as the CIPs coated on the graphite. - Highlights: • Absorbers filled with CIPs coating on the graphite was fabricated. • The permittivity and permeability increased as CIPs coated. • The CIP materials enhanced the electromagnetic property. • The graphite coated CIPs were effective in 2–18 GHz. - Abstract: The hybrid absorbent filled with carbonyl iron particles (CIPs) coating on the graphite was prepared using a chemical vapor decomposition (CVD) process. X-ray diffraction (XRD) patterns were done to analyze the particle crystal grain structure. The complex permittivity and permeability were measured using a vector network analyzer in the frequency range of 2–18 GHz. The results showed that α-Fe appeared in the super-lattice diffraction peaks in XRD graph. The composites added CIPs coating on the graphite had a higher permittivity and imaginary permeability due to the superior microwave dielectric loss and magnetic loss of the CIPs. The reflection loss (RL) result showed that composites filled with 5 vol% Fe-graphite had an excellent absorbing property in the 2–18 GHz, the minimum RL was −25.14 dB at 6 mm and −26.52 dB at 8 mm, respectively.

  4. A new neutron absorber material for criticality control

    International Nuclear Information System (INIS)

    Wells, Alan H.

    2007-01-01

    A new neutron absorber material based on a nickel metal matrix composite has been developed for applications such as the Transport, Aging, and Disposal (TAD) canister for the Yucca Mountain Project. This new material offers superior corrosion resistance to withstand the more demanding geochemical environments found in a 300,000 year to a million year repository. The lifetime of the TAD canister is currently limited to 10,000 years, reflecting the focus of current regulations embodied in 10 CFR 63. The use of DOE-owned nickel stocks from decommissioned enrichment facilities could reduce the cost compared to stainless steel/boron alloy. The metal matrix composite allows the inclusion of more than one neutron absorber compound, so that the exact composition may be adjusted as needed. The new neutron absorber material may also be used for supplementary criticality control of stored or transported PWR spent fuel by forming it into cylindrical pellets that can be inserted into a surrogate control rod. (authors)

  5. Developmental Outcome of Preterm Infants with Intraventricular Hemorrhage at One and Two Years of Age.

    Science.gov (United States)

    Sostek, Anita Miller; And Others

    1987-01-01

    This study examined developmental outcome at 1 and 2 years in relation to the presence and severity of neonatal intraventricular hemorrhage. Intraventricular hemorrhage related to Bayley mental and motor scores and neurologic ratings at 1 year but not at 2 years. Significant associations were found between the 1- and 2-year measures but not…

  6. Outcomes of hip arthroscopy in patients aged 50 years or older compared with a matched-pair control of patients aged 30 years or younger.

    Science.gov (United States)

    Domb, Benjamin G; Linder, Dror; Finley, Zachary; Botser, Itamar B; Chen, Austin; Williamson, Joseph; Gupta, Asheesh

    2015-02-01

    Age has been suggested as a negative prognostic factor for hip arthroscopy. The purpose of this study was to compare patient characteristics and outcomes after hip arthroscopy in patients aged 50 years or older with a matched control group of patients aged 30 years or younger at a minimum postoperative follow-up of 2 years. Between September 2008 and March 2010, data were prospectively collected on all patients aged 50 years or older undergoing primary hip arthroscopy. Fifty-two patients met our inclusion and matching criteria, of whom all 52 (100%) were available for follow-up at a minimum of 2 years. This cohort was compared with a matched-pair control group of patients aged 30 years or younger who underwent similar procedures. The mean age of the study group was 54.8 years (range, 50 to 69 years), and that of the control group was 20.3 years (range, 13 to 30 years). The groups were matched at a 1:1 ratio, including 18 male patients (34.6%) and 34 female patients (65.4%) in each group, with a mean follow-up period of 32 months (range, 24 to 54 months). In the younger control group, the score improvement from preoperatively to 2 years' follow-up was 62.9 to 84.2 for the modified Harris Hip Score, 60.5 to 84.2 for the Non-Arthritic Hip Score, 63.1 to 86.5 for the Hip Outcome Score-Activities of Daily Living, and 42.2 to 72.7 for the Hip Outcome Score-Sport-Specific Subscale. In the older study group, the score improvement from preoperatively to 2 years' follow-up was 61.2 to 82.2 for the modified Harris Hip Score, 59.9 to 80.4 for the Non-Arthritic Hip Score, 63.9 to 83 for the Hip Outcome Score-Activities of Daily Living, and 41.2 to 64.6 for the Hip Outcome Score-Sport-Specific Subscale. All improvements in both groups were statistically significant at the 2-year postoperative follow-up (P arthroscopy should be considered a valid treatment option when treating hip pain in patients aged 50 years or older with a Tönnis arthritic grade of 0 or 1. Older patients

  7. Employment outcome and predictors of competitive employment at 2-year follow-up of a vocational rehabilitation programme for individuals with schizophrenia in a high-income welfare society.

    Science.gov (United States)

    Evensen, Stig; Ueland, Torill; Lystad, June Ullevoldsæter; Bull, Helen; Klungsøyr, Ole; Martinsen, Egil W; Falkum, Erik

    2017-04-01

    Employment is an important part of recovery for individuals with schizophrenia. The employment rate for this group is as low as 10% in Norway, and major system related barriers to employment are evident. This study reports the competitive employment outcome at 2-year follow-up of a vocational rehabilitation study augmented with cognitive remediation (CR) or elements from cognitive behaviour therapy (CBT) for individuals with schizophrenia spectrum disorders. It also investigates if global functioning, self-esteem, and depression at baseline predicts employment outcome, and if change in these variables during the intervention period is associated with employment outcome. One hundred and forty-eight participants with schizophrenia spectrum disorders in six Norwegian counties received 10 months vocational rehabilitation augmented with either CBT (n = 84) or CR (n = 64). Both competitive and sheltered workplaces were used. Participants were assessed at baseline, at the end of the intervention period, and at 2-year follow-up. At 2-year follow-up, 21.2% had obtained competitive employment. A further 25.3% had work placements in competitive workplaces. Significant improvements were found in global functioning, self-esteem, and depression during the intervention period, but no significant differences between the two intervention groups. High baseline global functioning and self-esteem, as well as positive change in these variables during the intervention period, were significantly associated with higher competitive employment outcome at 2-year follow-up. The results add to existing evidence that competitive employment is attainable for individuals with schizophrenia. High global functioning and self-esteem were strongly associated with competitive employment outcome.

  8. Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-d- glucose using whole-body positron emission tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Deloar, H.M.; Fujiwara, Takehiko; Shidahara, Miho; Nakamura, Takashi; Watabe, Hiroshi; Narita, Yuichiro; Itoh, Masatoshi; Miyake, Masayasu; Watanuki, Shoichi

    1998-01-01

    The purpose of this study was to measure the cumulated activity and absorbed dose in organs after i.v. administration of 18 F-FDG using whole-body PET and MRI. Whole-body dynamic emission scans for 18 F-FDG were performed in six normal volunteers after transmission scans. The total activity of a source organ was obtained from the activity concentration of the organ measured by whole-body PET and the volume of that organ measured by whole-body T1-weighted MRI. The cumulated activity of each source organ was calculated from the time-activity curve. Absorbed doses to the individuals were estimated by the MIRD (medical internal radiation dosimetry) method. Another calculation of cumulated activities and absorbed doses was performed using the organ volumes from the MIRD phantom and the ''Japanese reference man'' to investigate the discrepancy of actual individual results against the phantom results. The cumulated activities of 18 source organs were calculated, and absorbed doses of 27 target organs estimated. Among the target organs, bladder wall, brain and kidney received the highest doses for the above three sets of organ volumes. Using measured individual organ volumes, the average absorbed doses for those organs were found to be 3.1 x 10 -1 , 3.7 x 10 -2 and 2.8 x 10 -2 mGy/MBq, respectively. The mean effective doses in this study for individuals of average body weight (64.5 kg) and the MIRD phantom of 70 kg were the same, i.e. 2.9 x 10 -2 mSv/MBq, while for the Japanese reference man of 60 kg the effective dose was 2.1 x 10 -2 mSv/MBq. The results for measured organ volumes derived from MRI were comparable to those obtained for organ volumes from the MIRD phantom. Although this study considered 18 F-FDG, combined use of whole-body PET and MRI might be quite effective for improving the accuracy of estimations of the cumulated activity and absorbed dose of positron-labelled radiopharmaceuticals.(orig./MG) (orig.)

  9. Investigation of reactivity change and neutron noise due to random absorber vibrations. 2

    International Nuclear Information System (INIS)

    Barthel, R.

    1984-01-01

    Perturbations of the neutron flux due to stochastically excited vibrations of absorbers have been investigated using a one-dimensional core model with N pointlike absorbers. Taking into account the flux depressions near the absorbers, pronounced peaks in the spectral power densities of the flux fluctuations have been found at multiples of the resonance frequencies in addition to the direct imaging of the resonances of absorber vibrations. Investigation of the space dependence of the corresponding transfer functions has shown that a localization is possible by means of the double frequency effect and that the dispersion of absorber vibrations can be determined by using the triple frequency effect. The conclusions of the paper are qualitatively compared with results of noise measurements at a pressurized water reactor. (author)

  10. Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with coronary artery stenosis: Rationale and design of the German–Austrian ABSORB RegIstRy (GABI-R)

    Energy Technology Data Exchange (ETDEWEB)

    Nef, Holger, E-mail: holger.nef@innere.med.uni-giessen.de [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Wiebe, Jens [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Achenbach, Stefan [University of Erlangen, Medizinische Klinik II, Department of Cardiology, Erlangen (Germany); Münzel, Thomas [Department of Medicine II, University Medical Center, Johannes Gutenberg University Mainz, Mainz (Germany); Naber, Christoph [Klinik für Kardiologie und Angiologie, Elisabeth-Krankenhaus, Essen (Germany); Richardt, Gert [Herzzentrum, Segeberger Kliniken GmbH, Bad Segeberg (Germany); Mehilli, Julinda [Department of Cardiology, Klinikum Großhadern, Ludwig- Maximilian Universität, Munich (Germany); Wöhrle, Jochen [Department of Internal Medicine II, University of Ulm, Ulm (Germany); Neumann, Till; Biermann, Janine [University of Essen, Department of Cardiology, Essen (Germany); Zahn, Ralf [Abteilung für Kardiologie, Herzzentrum Ludwigshafen, Ludwigshafen (Germany); Kastner, Johannes [Department of Cardiology, University of Vienna Medical School, Vienna (Austria); Schmermund, Axel [CCB, Cardioangiologisches Centrum Bethanien, Frankfurt (Germany); Pfannebecker, Thomas [Abbott Vascular Deutschland GmbH, Wetzlar (Germany); Schneider, Steffen; Limbourg, Tobias [Institut für Herzinfarktforschung, Ludwigshafen (Germany); Hamm, Christian W. [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany)

    2016-01-15

    Background: Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2–4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side effects. Methods/design: The short- and long-term outcome after implantation of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) in the world-wide greatest all-comers cohort will be evaluated in the prospective, non-interventional, multicenter German–Austrian ABSORB RegIstRy (GABI-R). GABI-R will include over 5000 patients from about 100 study sites in Austria and Germany. Safety endpoints such as cardiac death, myocardial infarction, and clinically driven percutaneous or surgical target lesion and vessel revascularization will be evaluated during hospitalization and in the follow-up period (minimum of 5 years). Conclusion: Although two randomized controlled trials and several registries have documented safety and efficacy as well as non-inferiority of this everolimus-eluting ABSORB device compared with drug-eluting metal stents, the current knowledge regarding clinical application, treatment success, and long-term safety of using this BRS in daily routine is limited. Thus, the goal of GABI-R is to address this lack of information. - Highlights: • The GABI-R addresses a lack of data about bioresorbable scaffolds in daily practice. • 5000 patients with minimal in- and exclusion criteria at 100 sites will

  11. Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with coronary artery stenosis: Rationale and design of the German–Austrian ABSORB RegIstRy (GABI-R)

    International Nuclear Information System (INIS)

    Nef, Holger; Wiebe, Jens; Achenbach, Stefan; Münzel, Thomas; Naber, Christoph; Richardt, Gert; Mehilli, Julinda; Wöhrle, Jochen; Neumann, Till; Biermann, Janine; Zahn, Ralf; Kastner, Johannes; Schmermund, Axel; Pfannebecker, Thomas; Schneider, Steffen; Limbourg, Tobias; Hamm, Christian W.

    2016-01-01

    Background: Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2–4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side effects. Methods/design: The short- and long-term outcome after implantation of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) in the world-wide greatest all-comers cohort will be evaluated in the prospective, non-interventional, multicenter German–Austrian ABSORB RegIstRy (GABI-R). GABI-R will include over 5000 patients from about 100 study sites in Austria and Germany. Safety endpoints such as cardiac death, myocardial infarction, and clinically driven percutaneous or surgical target lesion and vessel revascularization will be evaluated during hospitalization and in the follow-up period (minimum of 5 years). Conclusion: Although two randomized controlled trials and several registries have documented safety and efficacy as well as non-inferiority of this everolimus-eluting ABSORB device compared with drug-eluting metal stents, the current knowledge regarding clinical application, treatment success, and long-term safety of using this BRS in daily routine is limited. Thus, the goal of GABI-R is to address this lack of information. - Highlights: • The GABI-R addresses a lack of data about bioresorbable scaffolds in daily practice. • 5000 patients with minimal in- and exclusion criteria at 100 sites will

  12. Pregnancy Outcome of Multiparous Women Aged over 40 Years

    Science.gov (United States)

    Ates, Seda; Batmaz, Gonca; Sevket, Osman; Molla, Taner; Dane, Cem; Dane, Banu

    2013-01-01

    Objective. The aim of this study was to evaluate the effect of maternal age on prenatal and obstetric outcome in multiparaous women. Materials and Methods. A retrospective case control study was conducted, including women aged 40 years and over (study group, n = 97) who delivered at 20 week's gestation or beyond and women aged 20–29 years (control group, n = 97). Results. The mean age of women in the study group was 41.2 ± 1.7 years versus 25.4 ± 2.3 years in the control group. Advanced maternal age was associated with a significantly higher rate of hypertension, diabetes mellitus, fetal complication, and 5-minute Apgar scores <7 (P < 0.05). Caeserean section rate, incidence of placental abruption, preterm delivery, and neonatal intensive care unit admission were more common in the older group, but the differences were not statistically significant. Conclusions. Advanced maternal age is related to maternal and neonatal complications. PMID:25954770

  13. Fabrication of a saturable absorber WS2 and its mode locking in solid-state laser

    Science.gov (United States)

    Zhang, Chun-Yu; Zhang, Ling; Tang, Xiao-Ying; Yang, Ying-Ying

    2018-04-01

    We report on a passively mode-locked Nd : LuVO4 laser using a type saturable absorber of tungsten disulfide (WS2) fabricated by chemical vapor deposition method. At the pump power of 3.3 W, 1.18-W average output power of continuous-wave mode-locked laser with optical conversion efficiency of 36% was achieved. To the best of our knowledge, this is the highest output power of passively mode-locked solid-state laser based on WS2. The repetition rate of passively mode-locked pulse was 80 MHz with the pulse energy of 14.8 nJ. Our experimental results show that WS2 is an excellent type of saturable absorber.

  14. Long-term outcomes five years after selective dorsal rhizotomy

    Directory of Open Access Journals (Sweden)

    Lagergren Jan

    2008-12-01

    Full Text Available Abstract Background Selective dorsal rhizotomy (SDR is a well accepted neurosurgical procedure performed for the relief of spasticity interfering with motor function in children with spastic cerebral palsy (CP. The goal is to improve function, but long-term outcome studies are rare. The aims of this study were to evaluate long-term functional outcomes, safety and side effects during five postoperative years in all children with diplegia undergoing SDR combined with physiotherapy. Methods This study group consisted of 35 children, consecutively operated, with spastic diplegia, of which 26 were Gross Motor Function Classification System (GMFCS levels III–V. Mean age was 4.5 years (range 2.5–6.6. They were all assessed by the same multidisciplinary team at pre- and at 6, 12, 18 months, 3 and 5 years postoperatively. Clinical and demographic data, complications and number of rootlets cut were prospectively registered. Deep tendon reflexes and muscle tone were examined, the latter graded with the modified Ashworth scale. Passive range of motion (PROM was measured with a goniometer. Motor function was classified according to the GMFCS and measured with the Gross Motor Function Measure (GMFM-88 and derived into GMFM-66. Parent's opinions about the children's performance of skills and activities and the amount of caregiver assistance were measured with Pediatric Evaluation Disability Inventory (PEDI. Results The mean proportion of rootlets cut in S2-L2 was 40%. Muscle tone was immediately reduced in adductors, hamstrings and dorsiflexors (p Conclusion SDR is a safe and effective method for reducing spasticity permanently without major negative side effects. In combination with physiotherapy, in a group of carefully selected and systematically followed young children with spastic diplegia, it provides lasting functional benefits over a period of at least five years postoperatively.

  15. Current LH{sub 2}-absorber R and D in MuCool

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, M A C [Northern Illinois University, DeKalb, IL 60115 (United States); Allspach, D [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Bandura, L [Northern Illinois University, DeKalb, IL 60115 (United States); Black, E L [Illinois Institute of Technology, Chicago, IL 60616 (United States); Cassel, K W [Illinois Institute of Technology, Chicago, IL 60616 (United States); Dyshkant, A [Northern Illinois University, DeKalb, IL 60115 (United States); Errede, D [University of Illinois at Urbana-Champaign, Urbana, IL 61801 (United States); Geer, S [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Greenwood, J [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Haney, M [University of Illinois at Urbana-Champaign, Urbana, IL 61801 (United States); Hedin, D [Northern Illinois University, DeKalb, IL 60115 (United States); Ishimoto, S [KEK, Tsukuba 305 (Japan); Johnstone, C J [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Kaplan, D M [Illinois Institute of Technology, Chicago, IL 60616 (United States); Kubik, D [Northern Illinois University, DeKalb, IL 60115 (United States); Kuno, Y [Osaka University, Osaka 567 (Japan); Lau, W [University of Oxford, Oxford OX1 3NP (United Kingdom); Majewski, S [University of Illinois at Urbana-Champaign, Urbana, IL 61801 (United States); Norem, J [Argonne National Laboratory, Argonne, IL 60439 (United States); Norris, B [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Popovic, M [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Reep, M [University of Mississippi, University, MS 38677 (United States); Summers, D [KEK, Tsukuba 305 (Japan); Yoshimura, K [KEK, Tsukuba 305 (Japan)

    2003-08-01

    The MuCool hydrogen-absorber R and D program is summarized. Prototype absorbers featuring thin aluminum windows and 'flow-through' or 'convection' cooling are under development for eventual power-handling tests in a proton beam and a cooling demonstration in a muon beam. Testing these prototypes and their components involves application of novel techniques.

  16. Antenatal and postnatal growth and 5-year cognitive outcome in very preterm infants.

    Science.gov (United States)

    Leppänen, Marika; Lapinleimu, Helena; Lind, Annika; Matomäki, Jaakko; Lehtonen, Liisa; Haataja, Leena; Rautava, Päivi

    2014-01-01

    To study how antenatal growth affects cognitive outcome in very preterm infants and to determine whether there is an association between growth in any particular time period between birth and 5 years of age and cognitive outcome. Small for gestational age (SGA) and non-SGA infants were analyzed separately, because antenatal growth may affect postnatal growth. Very low birth weight (growth was determined as a z score change between measurement points. Cognitive development was assessed at 5 years of age with the Wechsler Preschool and Primary Scales of Intelligence-Revised. The association between growth and full-scale IQ (FSIQ) was studied. Growth in length and height was not associated with 5-year cognitive outcome. However, weight (r = 0.18, P = .04) and HC growth (r = 0.25, P = .01) between birth and 2 years of corrected age correlated to FSIQ in non-SGA children. In SGA children, HC growth (r = 0.33, P = .03) around term age correlated to FSIQ. Cognitive outcome was similar in SGA and non-SGA very preterm infants. Growth affected cognition positively in both subgroups, but the critical time period was different.

  17. Renal outcome of type 2 diabetes in South Africa - a 12-year follow ...

    African Journals Online (AJOL)

    Aims. Previous studies of type 2 diabetes mellitus have indicated a benign renal outcome after long-term follow-up. The aim of this study was to determine how often renal failure due to diabetic nephropathy was a cause of death in patients with type 2 diabetes. Methods. Prospective observational study of 59 South African ...

  18. Burnable absorber coated nuclear fuel

    International Nuclear Information System (INIS)

    Chubb, W.; Radford, K.C.; Parks, B.H.

    1984-01-01

    A nuclear fuel body which is at least partially covered by a burnable neutron absorber layer is provided with a hydrophobic overcoat generally covering the burnable absorber layer and bonded directly to it. In a method for providing a UO 2 fuel pellet with a zirconium diboride burnable poison layer, the fuel body is provided with an intermediate niobium layer. (author)

  19. Thermally tunable broadband omnidirectional and polarization-independent super absorber using phase change material VO2

    Directory of Open Access Journals (Sweden)

    Zhejun Liu

    Full Text Available In this letter, we numerically demonstrate a thermally tunable super absorber by using phase change material VO2 as absorbing layer in metal-insulator-metal structure. An omnidirectional super absorption at λ=2.56μm can be realized by heating the patterned grating VO2 film due to magnetic resonance mechanism. Furthermore, a broadband super absorption higher than 0.8 in the entire 1.6μm–4μm region is achieved when VO2 film is patterned chessboard structure and transformed to metal phase beyond transition temperature. This broadband super absorption can be fulfilled in a wide range of incident angle (0°–70° and under all polarization conditions. Keywords: Phase change material, Metal-insulator-metal, Super absorption, Magnetic resonance

  20. Clinical Outcomes after Conservative Management of Cervical Intraepithelial Neoplasia Grade 2 (CIN2) in Women Ages 21-39 Years.

    Science.gov (United States)

    Silver, Michelle I; Gage, Julia C; Schiffman, Mark; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas; Cheung, Li C; Katki, Hormuzd A; Locke, Alexander; Kinney, Walter K; Castle, Philip E

    2018-03-01

    Cervical intraepithelial neoplasia grade 2 (CIN2) frequently regresses, is typically slow-growing, and rarely progresses to cancer. Some women forgo immediate treatment, opting for conservative management (heightened surveillance with cytology and colposcopy), to minimize overtreatment and increased risk of obstetric complications; however, there are limited data examining clinical outcomes in these women. We performed a retrospective cohort analysis of younger women diagnosed with initially untreated CIN1/2, CIN2 and CIN2/3 lesions at Kaiser Permanente Northern California between 2003 and 2015. Clinical outcomes were categorized into five mutually exclusive hierarchical groups: cancer, treated, returned to routine screening, persistent high-grade lesion, or persistent low-grade lesion. Median follow-up for the 2,417 women was 48 months. Six women were diagnosed with cancer (0.2%), all with history of high-grade cytology, and none after a negative cotest. Thirty percent of women were treated, and only 20% returned to routine screening; 50% remained in continued intensive follow-up, of which 86% had either low-grade cytology/histology or high-risk human papillomavirus (HPV) positivity, but not necessarily persistence of a single HPV type. No cancers were detected after a single negative cotest in follow-up. Almost half of initially untreated women did not undergo treatment, but remained by protocol in colposcopy clinic for 2 or more years in the absence of persisting CIN2 + Their incomplete return to total negativity was possibly due to sequential new and unrelated low-grade abnormalities. The prolonged colposcopic surveillance currently required to return to routine screening in the absence of persisting CIN2 + might not be necessary after a negative cotest. Significance: Many younger women under conservative management following an initial CIN2 result remain in a clinical protocol of prolonged intensified surveillance without a subsequent diagnosis of CIN2 or more

  1. Thermal Shielding Effects of a Damaged Shock Absorber and an Intact Shock Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K. S.; Lee, J. C.; Kim, K. Y.; Seo, C. S.; Seo, K. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    In order to safely transport the radioactive waste arising from the hot test of an ACP(Advanced Spent Fuel Conditioning Process) a shipping package is required. Therefore, KAERI is developing a shipping package to transport the radioactive waste arising from the ACPF during a hot test. The regulatory requirements for a Type B package are specified in the Korea Most Act 2009-37, IAEA Safety Standard Series No. TS-R-1, and US 10 CFR Part. These regulatory guidelines classify the hot cell cask as a Type B package, and state that the Type B package for transporting radioactive materials should be able to withstand a test sequence consisting of a 9 m drop onto an unyielding surface, a 1 m drop onto a puncture bar, and a 30 minute fully engulfing fire. Greiner et al. investigated the thermal protection provided by shock absorbers by using the CAFE computer code. To evaluate the thermal shielding effect of the shock absorber, the thermal test was performed by using a 1/2 scale model with a shock absorber which was damaged by both a 9 m drop test and a 1 m puncture test. For the purpose of comparison, the thermal test was also carried out by using a 1/2 scale model with the intact shock absorber

  2. Removal of Cu2+ from Wastewater Using Synthesized Magnetite Bentonite Nano-absorbent

    Directory of Open Access Journals (Sweden)

    Gholamhossein Nourmohammadi

    2015-12-01

    Full Text Available The objective of the present study was to investigate absorption of copper from wastewater using the synthesized magnetite (Fe3O4 bentonite nanoadsorbent. Synthesized magnetite-bentonite nanoparticles (20‒40 nm were produced using the coprecipitation method and subsequently subjected to Scanning Electron Microscopy (SEM, X-Ray Diffraction (XRD, and Fourier Transform Infrared Spectroscopy (FT-IR for analysis and evaluation. The nanoparticles were finally used as an adsorbent in wastewater treatment. Experiments were also designed using the Design of Experiment (DOE software. Absorbent quantity, contact time, Cu+2 concentration , and pH were the most important factors selected for investigation. In a second step, the CCD design model was used to identify the optimum conditions for achieving the best metal ion absorption (removal efficiency. It was found that 89% of Copper metal ions were absorbed under optimum conditions. Finally, experiments were performed on the inorganic effluent (from the Sarcheshme Copper Mines under the optimum conditions. Results revealed a sorption content of 30% for Cu2+..

  3. Biofeedback therapy combined with diet to treating ODS (Anismus: 2 years outcome

    Directory of Open Access Journals (Sweden)

    Fakhryalsadat Anaraki

    2017-04-01

    Full Text Available Object: The advantages of biofeedback therapy along with diet in patients with constipation are among the issues discussed nowadays. The aim of this study was to evaluate 2 years outcome of biofeedback therapy along with diet in patients with obstructed defecation syndrome (ODS (Anismus. Methodology: The focus of this prospective study is a group of 129 patients with ODS constipation, who were referred to two tertiary-care referral academic centers from 2013 to 2016. Patients received biofeedback therapy combined with appropriate diet in cases group and received diet in controls group. Good response was defined as a subject with at least 50 percent improvement from before to after biofeedback therapy on a Cleveland Clinic Florida Constipation Scoring System (CCF. Factors associated with better outcome were analyzed using SPSS 20 software. Results: Out of the 129 patients, 112 patients (86.8% were female. The mean age of patients was 42.44 ± 15.05 years. The mean CCF score of the patients before and after biofeedback therapy was 12.41 ± 4.39 and 6.00 ± 3.28 respectively in case group (p-value < 0.001. In addition, the mean CCF score of the patients before and after diet therapy was 12.82 ± 4.85 and 9.43 ± 3.79 respectively in control group (p-value < 0.001. While CCF score in both case and control groups reduced significantly after therapy, the rate of this reduction was higher in case group (p < 0.001. Conclusion: Our findings suggest that biofeedback therapy combined with diet will improve patients outcome in ODS constipation. Prospective clinical trials with larger sample sizes are recommend allowing for causal correlations. Resumo: Objetivo: As vantagens da terapia por biofeedback, juntamente com a dieta, em pacientes com constipação se situam entre os tópicos atualmente em discussão. O objetvo desse estudo foi avaliar os resultados, após 2 anos, da terapia por biofeedback associada à dieta em pacientes com s

  4. Treatment outcomes of childhood tuberculosis in Addis Ababa: a five-year retrospective analysis

    Directory of Open Access Journals (Sweden)

    Genene Tilahun

    2016-07-01

    Full Text Available Abstract Background Tuberculosis (TB kills one child every 5 min. Childhood TB is given low priority in most national health programmes particularly in TB-endemic areas. TB among children is an indicator of a recent transmission of the disease in the community. Treatment outcome results serve as a proxy of the quality of treatment provided by a health care system. In Ethiopia, data on treatment outcomes of childhood TB are limited. The aim of the study was to determine the treatment outcomes of childhood TB in a hospital setting in Addis Ababa. Methods The study was conducted during June to August 2014. The data of 491 children treated for TB in Zewditu Memorial Hospital during a 5 year (2009–2013 was analysed. TB was diagnosed using standard methods. Demographic and clinical data including type of TB, TB-HIV co-infection and treatment outcomes were collected from registry of the TB clinic. Treatment outcome definitions are used according to the World Health Organization. Results Of the 491 children, 272(55.4 % were females, 107(21.8 % were under 5 year old, 454(92.5 % of them were new cases. The types of TB were extra-pulmonary tuberculosis (EPTB 243(49.5 % and 248(50.5 % pulmonary tuberculosis (PTB. Of the PTB cases, 42(16.9 % were sputum smear positive. Of the 291 children tested for HIV, 82(28.2 % were positive. The overall treatment success rate was 420(85.5 % and the poor treatment outcome was 71(14.5 %. Of the children with poor treatment outcome, 9(1.8 % died, 3(0.6 % defaulted from treatment, 2(0.4 % were treatment failure and 55(11.2 % were transferred out. Males and females had similar treatment success rates of 85.8 % and 85.3 %, respectively. Infants under one year had significantly lower treatment success rate of 72.7 % compared to those above 1 years of age of 86.5 % (P < 0.001. Treatment success rate ranged from 78.0 to 92.6 % during the study period. Associated factors for treatment outcome were age above

  5. Narrowing the Gap in Outcomes: Early Years (0-5 Years)

    Science.gov (United States)

    Springate, Ian; Atkinson, Mary; Straw, Suzanne; Lamont, Emily; Grayson, Hilary

    2008-01-01

    This report was commissioned by the Local Government Association (LGA) to inform the Department for Children, Schools and Families (DCSF) and LGA work on "Narrowing the Gap." It focuses on early years' provision and presents findings from a review of the best evidence on narrowing the gap in outcomes across the five Every Child Matters…

  6. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Adjunctive naturopathic care for type 2 diabetes: patient-reported and clinical outcomes after one year

    Directory of Open Access Journals (Sweden)

    Bradley Ryan

    2012-04-01

    Full Text Available Abstract Background Several small, uncontrolled studies have found improvements in self-care behaviors and reductions in clinical risk in persons with type 2 diabetes who received care from licensed naturopathic physicians. To extend these findings and determine the feasibility and promise of a randomized clinical trial, we conducted a prospective study to measure the effects of adjunctive naturopathic care (ANC in primary care patients with inadequately controlled type 2 diabetes. Methods Forty patients with type 2 diabetes were invited from a large integrated health care system to receive up to eight ANC visits for up to one year. Participants were required to have hemoglobin A1c (HbA1c values between 7.5-9.5 % and at least one additional cardiovascular risk factor (i.e., hypertension, hyperlipidemia or overweight. Standardized instruments were administered by telephone to collect outcome data on self-care, self-efficacy, diabetes problem areas, perceived stress, motivation, and mood. Changes from baseline scores were calculated at 6- and 12-months after entry into the study. Six and 12-month changes in clinical risk factors (i.e., HbA1c, lipid and blood pressure were calculated for the ANC cohort, and compared to changes in a cohort of 329 eligible, non-participating patients constructed using electronic medical records data. Between-cohort comparisons were adjusted for age, gender, baseline HbA1c, and diabetes medications. Six months was pre-specified as the primary endpoint for outcome assessment. Results Participants made 3.9 ANC visits on average during the year, 78 % of which occurred within six months of entry into the study. At 6-months, significant improvements were found in most patient-reported measures, including glucose testing (P = 0.001, diet (P = 0.001, physical activity (P = 0.02, mood (P = 0.001, self-efficacy (P = 0.0001 and motivation to change lifestyle (P = 0.003. Improvements in glucose testing, mood, self-efficacy and

  8. The CVD ZrB2 as a selective solar absorber

    Science.gov (United States)

    Randich, E.; Allred, D. D.

    Coatings of ZrB2 and TiB2 for photothermal solar absorber applications were prepared using chemical vapor deposition (CVD) techniques. Oxidation tests suggest a maximum temperature limit for air exposure of 600 K for TiB2 and 800 K for Z4B2. Both materials exhibit innate spectral selectivity with emittance at 375 K ranging from 0.06 to 0.09 and solar absorptance for ZrB2 ranging from 0.67 to 0.77 and solar absorptance for TiB2 ranging from 0.46 to 0.58. ZrB2 has better solar selectivity and more desirable oxidation behavior than TiB2. A 0.071 micrometer antireflection coating of Si3N4 deposited on the ZrB2 coating leads to an increase in absorptance from 0.77 to 0.93, while the emittance remains unchanged.

  9. Burnable neutron absorbers

    International Nuclear Information System (INIS)

    Radford, K.C.; Carlson, W.G.

    1985-01-01

    This patent deals with the fabrication of pellets for neutron absorber rods. Such a pellet includes a matrix of a refractory material which may be aluminum or zirconium oxide, and a burnable poison distributed throughout the matrix. The neutron absorber material may consist of one or more elements or compounds of the metals boron, gadolinium, samarium, cadmium, europium, hafnium, dysprosium and indium. The method of fabricating pellets of these materials outlined in this patent is designed to produce pores or voids in the pellets that can be used to take up the expansion of the burnable poison and to absorb the helium gas generated. In the practice of this invention a slurry of Al 2 O 3 is produced. A hard binder is added and the slurry and binder are spray dried. This powder is mixed with dry B 4 C powder, forming a homogeneous mixture. This mixture is pressed into green tubes which are then sintered. During sintering the binder volatilizes leaving a ceramic with nearly spherical high-density regions of

  10. Dynamic analytical and experimental research of shock absorber to safeguard the nuclear fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Dundulis, Gintautas, E-mail: gintas@mail.lei.lt [Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); Grybenas, Albertas [Laboratory of Materials Research and Testing, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); Karalevicius, Renatas [Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); Makarevicius, Vidas [Laboratory of Materials Research and Testing, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); Rimkevicius, Sigitas; Uspuras, Eugenijus [Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, Breslaujos str. 3, LT-44403 Kaunas (Lithuania)

    2013-07-15

    Highlights: • Plastical deformation of the shock absorber. • Dynamic testing of the scaled shock absorber. • Dynamic simulation of the shock absorber using finite element method. • Strain-rate evaluation in dynamic analysis. • Variation of displacement, acceleration and velocity during dynamic impact. -- Abstract: The Ignalina Nuclear Power Plant (NPP) has two RBMK-1500 graphite moderated boiling water multi-channel reactors. The Ignalina NPP Unit 1 was shut down at the end of 2004 while Unit 2 has been in operation for over 5 years. After shutdown at the Unit 1 remained spent fuel assemblies with low burn-up depth. In order to reuse these assemblies in the reactor of Unit 2 a special set of equipment was developed. One of the most important items of this set is a container, which is used for the transportation of spent fuel assemblies between the reactors of Unit 1 and Unit 2. A special shock absorber was designed to avoid failure of fuel assemblies in case of hypothetical spent fuel assemblies drop accident during uploading/unloading of spent fuel assemblies to/from container. This shock absorber was examined using scaled experiments and finite element analysis. Static and dynamic investigations of the shock absorber were performed for the estimation and optimization of its geometrical parameters. The objective of this work is the estimation whether the proposed design of shock absorber can fulfil the stopping function of the spent fuel assemblies and is capable to withstand the dynamics load. Experimental testing of scaled shock absorber models and dynamic analytical investigations using the finite element code ABAQUS/Explicit were performed. The simulation model was verified by comparing the experimental and simulation results and it was concluded that the shock absorber is capable to withstand the dynamic load, i.e. successful force suppression function in case of accident.

  11. Pool fire upon a balsa-filled shock absorber

    International Nuclear Information System (INIS)

    Fry, C.J.

    1990-07-01

    When performing a safety assessment of a transport flask with balsa-filled shock absorbers it is important to know how the shock absorbers, which may have the outer skin punctured by an impact, will perform in a fire. A 30 minute pool test, which satisfied all the requirements of a thermal test under the IAEA regulations, was carried out upon a small, balsa-filled shock absorber. The outer steel shell was partly cut away exposing the wood to the fire and the air. The balsa wood prevented 90% of the heat from the fire from being transferred through the shock absorber, even though the balsa was only 133 mm thick. The maximum heat flux through to the inside of the shock absorber due to the burning of the balsa wood was relatively low, 2.8 kW/m 2 , and occurred 2 to 3 hours after the end of the pool fire. (author)

  12. Nitrile-functionalized tertiary amines as highly efficient and reversible SO{sub 2} absorbents

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yun; Kim, Heehwan; Kim, Young Jin; Jeong, Junkyo; Cheong, Minserk [Department of Chemistry and Research Institute of Basic Sciences, Kyung Hee University, 1 Hoegi-dong, Dongdaemun-gu, Seoul 130-701 (Korea, Republic of); Lee, Hyunjoo [Clean Energy Center, Korea Institute of Science and Technology, Seoul 136-791 (Korea, Republic of); Kim, Hoon Sik, E-mail: khs2004@khu.ac.kr [Department of Chemistry and Research Institute of Basic Sciences, Kyung Hee University, 1 Hoegi-dong, Dongdaemun-gu, Seoul 130-701 (Korea, Republic of); Lee, Je Seung, E-mail: leejs70@khu.ac.kr [Department of Chemistry and Research Institute of Basic Sciences, Kyung Hee University, 1 Hoegi-dong, Dongdaemun-gu, Seoul 130-701 (Korea, Republic of)

    2014-01-15

    Highlights: • Nitrile-functionalized tertiary amines physically and reversibly absorb SO{sub 2}. • Tertiary alkanolamines chemically and irreversibly absorb SO{sub 2} through OH group. • SO{sub 2} absorption modes were studied by spectroscopy and computational calculations. -- Abstract: Three different types of nitrile-functionalized amines, including 3-(N,N-diethylamino)propionitrile (DEAPN), 3-(N,N-dibutylamino)propionitrile (DBAPN), and N-methyl-N,N-dipropionitrile amine (MADPN) were synthesized, and their SO{sub 2} absorption performances were evaluated and compared with those of hydroxy-functionalized amines such as N,N-diethyl-N-ethanol amine (DEEA), N,N-dibutyl-N-ethanol amine (DBEA), and N-methyl-N,N-diethanol amine (MDEA). Absorption–desorption cycle experiments clearly demonstrate that the nitrile-functionalized amines are more efficient than the hydroxy-functionalized amines in terms of absorption rate and regenerability. Computational calculations with DBEA and DBAPN revealed that DBEA bearing a hydroxyethyl group chemically interacts with SO{sub 2} through oxygen atom, forming an ionic compound with a covalently bound -OSO{sub 2}{sup −} group. On the contrary, DBAPN bearing a nitrile group physically interacts with SO{sub 2} through the nitrogen and the hydrogen atoms of the two methylene groups adjacent to the amino and nitrile functionalities.

  13. Report of the Clinical and Functional Primary Outcomes in Men of the ACL-SPORTS Trial: Similar Outcomes in Men Receiving Secondary Prevention With and Without Perturbation Training 1 and 2 Years After ACL Reconstruction.

    Science.gov (United States)

    Arundale, Amelia J H; Cummer, Kathleen; Capin, Jacob J; Zarzycki, Ryan; Snyder-Mackler, Lynn

    2017-10-01

    Athletes often are cleared to return to activities 6 months after anterior cruciate ligament (ACL) reconstruction; however, knee function measures continue to improve up to 2 years after surgery. Interventions beyond standard care may facilitate successful return to preinjury activities and improve functional outcomes. Perturbation training has been used in nonoperative ACL injury and preoperative ACL reconstruction rehabilitation, but has not been examined in postoperative ACL reconstruction rehabilitation, specifically return to sport rehabilitation. The purpose of this study was to determine whether there were differences at 1 and 2 years after ACL reconstruction between the male SAP (strengthening, agility, and secondary prevention) and SAP+PERT (SAP protocol with the addition of perturbation training) groups with respect to (1) quadriceps strength and single-legged hop limb symmetry; (2) patient-reported knee outcome scores; (3) the proportion who achieve self-reported normal knee function; and (4) the time from surgery to passing return to sport criteria. Forty men who had completed ACL reconstruction rehabilitation and met enrollment criteria (3-9 months after ACL reconstruction, > 80% quadriceps strength limb symmetry, no pain, full ROM, minimal effusion) were randomized into the SAP or SAP+PERT groups of the Anterior Cruciate Ligament-Specialised Post-Operative Return to Sports trial (ACL-SPORTS), a single-blind randomized clinical study of secondary prevention and return to sport. Quadriceps strength, single-legged hopping, the International Knee Documentation Committee (IKDC) 2000 subjective knee form, Knee Injury and Osteoarthritis Outcome Score (KOOS)-sports and recreation, and KOOS-quality-of-life subscales were collected 1 and 2 years after surgery by investigators blind to group. Athletes were categorized as having normal or abnormal knee function at each time point based on IKDC score, and the time until athletes passed strict return

  14. Design and development of radiation absorber for sighting beam line

    International Nuclear Information System (INIS)

    Sridhar, R.; Shukla, S.K.

    2005-01-01

    During the commissioning of Indus-2 , it is necessary to view the synchrotron radiation that will be emanating from the dipole exit ports. The 10 0 beam line from dipole 11 was earmarked for sighting beam line. The synchrotron radiation power density would be around 340 watts on the photon absorber inside the radiation absorber module, at the specified beam power of Indus-2. The beam striking on this photon absorber produces x-rays and Bremsstrahlung radiation. These are to be stopped and absorbed by radiation absorber. The photon absorber and the radiation absorber are integrated in a single vacuum chamber and actuated by a pneumatic cylinder connected using a bellow. Radiation absorber was needed to isolate the diagnostic components and to protect them from radiation a well as heat when they were not in use. The paper describes the design, calculation and development of the dynamic photon cum radiation absorber. The ultimate vacuum performance is also described. (author)

  15. Microstructured extremely thin absorber solar cells

    DEFF Research Database (Denmark)

    Biancardo, Matteo; Krebs, Frederik C

    2007-01-01

    In this paper we present the realization of extremely thin absorber (ETA) solar cells employing conductive glass substrates functionalized with TiO2 microstructures produced by embossing. Nanocrystalline or compact TiO2 films on Indium doped tin oxide (ITO) glass substrates were embossed by press......In this paper we present the realization of extremely thin absorber (ETA) solar cells employing conductive glass substrates functionalized with TiO2 microstructures produced by embossing. Nanocrystalline or compact TiO2 films on Indium doped tin oxide (ITO) glass substrates were embossed...

  16. Specific absorbed fractions of energy at various ages from internal photon sources: 3, Five-year-old

    International Nuclear Information System (INIS)

    Cristy, M.; Eckerman, K.F.

    1987-04-01

    Specific absorbed fractions (PHI's) in various organs of the body (target organs) from sources of monoenergetic photons in various other organs (source organs) are tabulated. In this volume PHI-values are tabulated for a five-year-old or 19-kg person. These PHI-values can be used in calculating the photon component of the dose-equivalent rate in a given target organ from a given radionuclide that is present in a given source organ. The International Commission on Radiological Protection recognizes that the endosteal, or bone surface, cells are the tissue at risk for bone cancer. We have applied the dosimetry methods developed for beta-emitting radionuclides deposited in bone to follow the transport of secondary electrons that were freed by photon interactions through the microscopic structure of the skeleton. With these methods we can estimate PHI in the endosteal cells and can better estimate PHI in the active marrow; the latter is overestimated with other methods at photon energies below 200 keV. 12 refs., 2 tabs

  17. Comparison of Immediate and 2-Year Outcomes between Excimer Laser-Assisted Angioplasty with Spot Stent and Primary Stenting in Intermediate to Long Femoropopliteal Disease

    Directory of Open Access Journals (Sweden)

    Tien-Yu Wu

    2013-01-01

    Full Text Available Background. To compare the clinical outcomes between excimer laser-assisted angioplasty (ELA with spot stent (group A and primary stenting (group B in intermediate to long femoropopliteal disease. Methods. Outcomes of 105 patients totaling 119 legs treated with two different strategies were analyzed retrospectively in a prospectively maintained database. Results. Baseline characteristics were similar in both groups. Better angiographic results and lesser increase of serum C-reactive protein levels (0.60 ± 0.72 versus 2.98 ± 0.97 mg/dL, P<0.001 after the intervention were obtained in Group B. Group A had inferior 1-year outcomes due to higher rate of binary restenosis (67% versus 32%, P=0.001 and lower rate of primary patency (40% versus 58%, P=0.039. Rates of amputation-free survival, target vessel revascularization, assisted primary patency, and stent fracture at 24 months were similar in both groups (80% versus 82%, P=0.979, 65% versus 45%, P=0.11, 78% versus 80%, P=0.75 and 6.3% versus 6.8%, P=0.71, resp.. Conclusion. Greater vascular inflammation after ELA with spot stent resulted in earlier restenosis and inferior 1-year clinical outcomes than primary stenting. This benefit was lost in the primary stenting group at 2 years due to late catch-up restenosis. Active surveillance with prompt intervention was required to maintain the vessel patency.

  18. Endoscopic Gluteus Medius Repair With Concomitant Arthroscopy for Labral Tears: A Case Series With Minimum 5-Year Outcomes.

    Science.gov (United States)

    Perets, Itay; Mansor, Yosif; Yuen, Leslie C; Chen, Austin W; Chaharbakhshi, Edwin O; Domb, Benjamin G

    2017-12-01

    To report the minimum 5-year outcomes of endoscopic gluteus medius repair for partial- and full-thickness tears with concomitant hip arthroscopy. Data for all patients who underwent hip arthroscopy between February 2009 and September 2011 were prospectively collected. We included patients who underwent endoscopic gluteus medius repair with concomitant arthroscopic labral treatment and for whom the following measures were obtained preoperatively and at a minimum of 5 years' follow-up: modified Harris Hip Score, Non-Arthritic Hip Score, Hip Outcome Score-Sports Specific Subscale, and visual analog scale score for pain. For included patients, the International Hip Outcome Tool-12 (iHOT-12) score and satisfaction rating were also available at latest follow-up. Patients with at least 1 of the following criteria were excluded: preoperative Tönnis osteoarthritis grade of 2 or greater, previous hip conditions, severe dysplasia, and Workers' Compensation claims. There were 16 patients eligible for inclusion, 14 (87.5%) of whom had minimum 5-year follow-up, with a mean of 68.8 months (range, 60.1-79.6 months). The study group consisted of 13 women (92.9%) and 1 man (7.1%) with a mean age at surgery of 57.4 years (range, 46.3-74.8 years). Outcome scores improved as follows: modified Harris Hip Score, from 52.4 to 81.2 (P = .004); Non-Arthritic Hip Score, from 48.0 to 82.5 (P = .002); Hip Outcome Score-Sports Specific Subscale, from 30.1 to 66.4 (P arthroscopy for labral tears is safe and shows favorable outcomes at minimum 5-year follow-up. Patient outcomes were as favorable at 5 years as they were at 2 years postoperatively. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Aperiodic-metamaterial-based absorber

    Directory of Open Access Journals (Sweden)

    Quanlong Yang

    2017-09-01

    Full Text Available The periodic-metamaterial-based perfect absorber has been studied broadly. Conversely, if the unit cell in the metamaterial-based absorber is arranged aperiodically (aperiodic-metamaterial-based absorber, how does it perform? Inspired by this, here we present a systematic study of the aperiodic-metamaterial-based absorber. By investigating the response of metamaterial absorbers based on periodic, Fibonacci, Thue-Morse, and quasicrystal lattices, we found that aperiodic-metamaterial-based absorbers could display similar absorption behaviors as the periodic one in one hand. However, their absorption behaviors show different tendency depending on the thicknesses of the spacer. Further studies on the angle and polarization dependence of the absorption behavior are also presented.

  20. Radioactive iodine absorbing properties of tetrathiafulvalene

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tomiyasu; Nakamura, Asao (Ajinomoto Co. Inc., Kawasaki, Kanagawa (Japan). Central Research Labs.); Nogawa, Norio; Oohashi, Kunio; Morikawa, Naotake

    1989-05-01

    For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the air at room temperature. (2) Absorbed amount of iodine on activated charcoal decreased with increasing gaseous iodine concentration, air flow rate, on humidity of flowing-air. On the other hand, those factors scarcely affected that on TTF. Under an air flow rate of 1m/s, activated charcoal absorbs only 80% of iodine, while TTF absorbs more than 99%. (3) In flowing-air saturated with water vapor, iodine absorbed on activated charcoal was gradually liberated although by small amount (0.08%/100h), while that on TTF was much more stable for a long period (0.004%/100h). As a conclusion, TTF is considered to be useful as a quite effective radioactive iodine absorbent, especially in the case where protection from radioactive iodine should be serious, though it is expensive now. (author).

  1. Radioactive iodine absorbing properties of tetrathiafulvalene

    International Nuclear Information System (INIS)

    Ito, Tomiyasu; Nakamura, Asao; Nogawa, Norio; Oohashi, Kunio; Morikawa, Naotake.

    1989-01-01

    For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and 125 I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the air at room temperature. (2) Absorbed amount of iodine on activated charcoal decreased with increasing gaseous iodine concentration, air flow rate, on humidity of flowing-air. On the other hand, those factors scarcely affected that on TTF. Under an air flow rate of 1m/s, activated charcoal absorbs only 80% of iodine, while TTF absorbs more than 99%. (3) In flowing-air saturated with water vapor, iodine absorbed on activated charcoal was gradually liberated although by small amount (0.08%/100h), while that on TTF was much more stable for a long period (0.004%/100h). As a conclusion, TTF is considered to be useful as a quite effective radioactive iodine absorbent, especially in the case where protection from radioactive iodine should be serious, though it is expensive now. (author)

  2. Association between breakfast consumption and educational outcomes in 9-11-year-old children.

    Science.gov (United States)

    Littlecott, Hannah J; Moore, Graham F; Moore, Laurence; Lyons, Ronan A; Murphy, Simon

    2016-06-01

    Breakfast consumption has been consistently associated with health outcomes and cognitive functioning in schoolchildren. Evidence of direct links with educational outcomes remains equivocal. We aimed to examine the link between breakfast consumption in 9-11-year-old children and educational outcomes obtained 6-18 months later. Data on individual-level free school meal entitlement and educational outcomes (Statutory Assessment Tests (SATs) at Key Stage 2) were obtained via the SAIL databank and linked to earlier data collected on breakfast consumption. Multilevel modelling assessed associations between breakfast consumption and SATs. Trial of the Primary School Free Breakfast Initiative in Wales. Year 5 and 6 students, n 3093 (baseline) and n 3055 (follow-up). Significant associations were found between all dietary behaviours and better performance in SATs, adjusted for gender and individual- and school-level free school meal entitlement (OR=1·95; CI 1·58, 2·40 for breakfast, OR=1·08; CI 1·04, 1·13 for healthy breakfast items). No association was observed between number of unhealthy breakfast items consumed and educational performance. Association of breakfast consumption with educational performance was stronger where the measure of breakfast consumption was more proximal to SATs tests (OR=2·02 measured 6 months prior to SATs, OR=1·61 measured 18 months prior). Significant positive associations between self-reported breakfast consumption and educational outcomes were observed. Future research should aim to explore the mechanisms by which breakfast consumption and educational outcomes are linked, and understand how to promote breakfast consumption among schoolchildren. Communicating findings of educational benefits to schools may help to enhance buy-in to efforts to improve health behaviours of pupils.

  3. Can items used in 4-year-old well-child visits predict children's health and school outcomes?

    Science.gov (United States)

    Smithers, Lisa G; Chittleborough, Catherine R; Stocks, Nigel; Sawyer, Michael G; Lynch, John W

    2014-08-01

    To examine whether items comprising a preschool well-child check for use by family doctors in Australia with 4-5-year old children predicts health and academic outcomes at 6-7 years. The well-child check includes mandatory (anthropometry, eye/vision, ear/hearing, dental, toileting, allergy problems) and non-mandatory (processed food consumption, low physical activity, motor, behaviour/mood problems) items. The predictive validity of mandatory and non-mandatory items measured at 4-5 years was examined using data from the Longitudinal Study of Australian Children. Outcomes at 6-7 years included overweight/obesity, asthma, health care/medication needs, general health, mental health problems, quality of life, teacher-reported mathematics and literacy ability (n = 2,280-2,787). Weight or height >90th centile at 4-5 years predicted overweight/obesity at 6-7 years with 60% sensitivity, 79% specificity and 40% positive predictive value (PPV). Mood/behaviour problems at 4-5 predicted mental health problems at 6-7 years with 86% sensitivity, 40% specificity and 8% PPV. Non-mandatory items improved the discrimination between children with and without mental health problems at 6-7 years (area under the receiver operating characteristic curve 0.75 compared with 0.69 for mandatory items only), but was weak for most outcomes. Items used in a well-child health check were moderate predictors of overweight/obesity and mental health problems at 6-7 years, but poor predictors of other health and academic outcomes.

  4. Absorbing rods for nuclear fast neutron reactor absorbing assembly

    International Nuclear Information System (INIS)

    Aji, M.; Ballagny, A.; Haze, R.

    1986-01-01

    The invention proposes a neutron absorber rod for neutron absorber assembly of a fast neutron reactor. The assembly comprises a bundle of vertical rods, each one comprising a stack of pellets made of a neutron absorber material contained in a long metallic casing with a certain radial play with regard to this casing; this casing includes traps for splinters from the pellets which may appear during reactor operation, at the level of contact between adjacent pellets. The present invention prevents the casing from rupture involved by the disintegration of the pellets producing pieces of boron carbide of high hardness [fr

  5. Treatment Outcome of Tuberculosis Patients under Directly Observed Treatment Short Course and Factors Affecting Outcome in Southern Ethiopia: A Five-Year Retrospective Study.

    Directory of Open Access Journals (Sweden)

    Gebremedhin Gebrezgabiher

    Full Text Available Tuberculosis (TB is one of the major public health and socio-economic issues in the 21st century globally. Assessment of TB treatment outcomes, and monitoring and evaluation of its risk factors in Directly Observed Treatment Short Course (DOTS are among the major indicators of the performance of a national TB control program. Hence, this institution-based retrospective study was conducted to determine the treatment outcome of TB patients and investigate factors associated with unsuccessful outcome at Dilla University Referral Hospital, southern Ethiopia. Five years (2008 to 2013 TB record of TB clinic of the hospital was reviewed. A total 1537 registered TB patients with complete information were included. Of these, 942 (61.3% were male, 1015 (66% were from rural areas, 544 (35.4% were smear positive pulmonary TB (PTB+, 816 (53.1% were smear negative pulmonary TB (PTB- and 177(11.5% were extra pulmonary TB (EPTB patients. Records of the 1537 TB patients showed that 181 (11.8% were cured, 1129(73.5% completed treatment, 171 (11.1% defaulted, 52 (3.4% died and 4 (0.3% had treatment failure. The overall mean treatment success rate of the TB patients was 85.2%. The treatment success rate of the TB patients increased from 80.5% in September 2008-August 2009 to 84.8% in September 2012-May 2013. Tuberculosis type, age, residence and year of treatment were significantly associated with unsuccessful treatment outcome. The risk of unsuccessful outcome was significantly higher among TB patients from rural areas (AOR = 1.63, 95% CI: 1.21-2.20 compared to their urban counterparts. Unsuccessful treatment outcome was also observed in PTB- patients (AOR = 1.77, 95% CI: 1.26-2.50 and EPTB (AOR = 2.07, 95% CI: 1.28-3.37 compared to the PTB+ patients. In conclusion, it appears that DOTS have improved treatment success in the hospital during five years. Regular follow-up of patients with poor treatment outcome and provision of health information on TB treatment to

  6. Methods for absorbing neutrons

    Science.gov (United States)

    Guillen, Donna P [Idaho Falls, ID; Longhurst, Glen R [Idaho Falls, ID; Porter, Douglas L [Idaho Falls, ID; Parry, James R [Idaho Falls, ID

    2012-07-24

    A conduction cooled neutron absorber may include a metal matrix composite that comprises a metal having a thermal neutron cross-section of at least about 50 barns and a metal having a thermal conductivity of at least about 1 W/cmK. Apparatus for providing a neutron flux having a high fast-to-thermal neutron ratio may include a source of neutrons that produces fast neutrons and thermal neutrons. A neutron absorber positioned adjacent the neutron source absorbs at least some of the thermal neutrons so that a region adjacent the neutron absorber has a fast-to-thermal neutron ratio of at least about 15. A coolant in thermal contact with the neutron absorber removes heat from the neutron absorber.

  7. Regeneration performance of CO2-rich solvents by using membrane vacuum regeneration technology: Relationships between absorbent structure and regeneration efficiency

    International Nuclear Information System (INIS)

    Yan, Shuiping; Fang, Mengxiang; Wang, Zhen; Luo, Zhongyang

    2012-01-01

    Highlights: ► MVR may be viable to successfully use less valuable heat to replace high grade steam. ► Increasing OH and amine groups will increase the regeneration efficiency. ► Absorbents with a four carbon chain length will be more attractive to MVR. ► Amino acid salts will be more appropriate for MVR. ► HRM conducted at ambient pressure and low temperature is inferior to MVR. -- Abstract: In order to give a better understanding for the selection of suitable absorbents for the novel membrane vacuum regeneration technology (MVR) which has the potential to reduce CO 2 energy requirement by utilizing the waste heat or low-grade energy, an experimental study to determine the relationships between chemical structure and vacuum regeneration behavior of CO 2 absorbents at 70 °C and 10 kPa was performed. Eleven typical absorbents with different functional groups in their chemical structures were investigated in terms of vacuum regeneration efficiencies. Results showed that the regeneration efficiency decreased with an increase of number of activated hydrogen atom in amine group and decreased with the number of hydroxyl group. Especially, more attention should be paid to these alkanolamines with one hydrogen atom in amine group and two or more hydroxyl groups in the structures due to their better comprehensive performance in regeneration, absorbent loss and CO 2 absorption aspects. Increasing the carbon chain length and amine groups in the absorbent structure contributed to the improvement of regeneration performance and reduction of absorbent volatile loss. These absorbents with a four carbon chain length bonded at amine group might be more attractive to MVR. Furthermore, polyamines were superior to monoamines in terms of higher regeneration efficiencies and lower absorbent losses. Additionally, the individual effects of the potassium carboxylate group and hydroxymethylene group were also compared in this study. Results showed that amino acid salts were more

  8. Kidney outcomes three years after bariatric surgery in severely obese adolescents.

    Science.gov (United States)

    Nehus, Edward J; Khoury, Jane C; Inge, Thomas H; Xiao, Nianzhou; Jenkins, Todd M; Moxey-Mims, Marva M; Mitsnefes, Mark M

    2017-02-01

    A significant number of severely obese adolescents undergoing bariatric surgery have evidence of early kidney damage. To determine if kidney injury is reversible following bariatric surgery, we investigated renal outcomes in the Teen-Longitudinal Assessment of Bariatric Surgery cohort, a prospective multicenter study of 242 severely obese adolescents undergoing bariatric surgery. Primary outcomes of urine albumin-to-creatinine ratio and cystatin C-based estimated glomerular filtration rate (eGFR) were evaluated preoperatively and up to 3 years following bariatric surgery. At surgery, mean age of participants was 17 years and median body mass index (BMI) was 51 kg/m 2 . In those with decreased kidney function at baseline (eGFR under 90 mL/min/1.73m 2 ), mean eGFR significantly improved from 76 to 102 mL/min/1.73m 2 at three-year follow-up. Similarly, participants with albuminuria (albumin-to-creatinine ratio of 30 mg/g and more) at baseline demonstrated significant improvement following surgery: geometric mean of ACR was 74 mg/g at baseline and decreased to 17 mg/g at three years. Those with normal renal function and no albuminuria at baseline remained stable throughout the study period. Among individuals with a BMI of 40 kg/m 2 and more at follow-up, increased BMI was associated with significantly lower eGFR, while no association was observed in those with a BMI under 40 kg/m 2 . In adjusted analysis, eGFR increased by 3.9 mL/min/1.73m 2 for each 10-unit loss of BMI. Early kidney abnormalities improved following bariatric surgery in adolescents with evidence of preoperative kidney disease. Thus, kidney disease should be considered as a selection criteria for bariatric surgery in severely obese adolescents who fail conventional weight management. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  9. Aetiological patterns and management outcome of paediatric head trauma: one-year prospective study.

    Science.gov (United States)

    Emejulu, J K C; Shokunbi, M T

    2010-09-01

    Trauma is the most common cause ofpaediatric deaths. In 75% ofpaediatric trauma deaths, head injury is responsible, and most are from falls. Recent reports from Nigeria, however, appear to indicate a predominance of road traffic accidents, instead of falls. To evaluate the aetiology of paediatric head trauma, management protocols and outcome from our Centre, in order to acquire a baseline data base and recommend measures to reduce childhood trauma. A prospective study of all paediatric head trauma cases presenting to Nnamdi Azikiwe University Teaching Hospital, Nnewi, for 12months from April 21, 2006 to April 20, 2007, was done and collated data subsequently analyzed. The paediatric age group was taken as = 15 years, and grading of head injury was with the Glasgow Coma Scale (3-15) and the modified scale for non-verbal children; while outcome was measured with the Glasgow Outcome Scale (1-5). Out of 334 patients treated within the period of study, 210 were head trauma cases. Of these, 52 were paediatric head trauma, representing 24.8% of all head trauma cases; and 19.2% (10 of 52) of them were aged 0-2 years. About 62% (32 of 52) were males. Falls and RTA were each responsible in 25 (48.1%) cases. Mild head injury occurred in 31 (59.6%), and 49 (94.2%) patients were evaluated by plain radiography. Treatment was conservative in 39 (75%) cases; with satisfactory outcome in 36 (69.2%), and a mortality rate of 15.4%. Road traffic injury, mostly from motorcycles, has become the major cause of morbidity and mortality amongst the paediatric age group, especially the male gender, and outcome from management is mostly satisfactory.

  10. UV-absorbing compounds in subarctic herbarium bryophytes

    Energy Technology Data Exchange (ETDEWEB)

    Huttunen, S. [Botany Division, Department of Biology, P.O. Box 3000, FIN-90 014 University of Oulu (Finland)]. E-mail: satu.huttunen@oulu.fi; Lappalainen, N.M. [Botany Division, Department of Biology, P.O. Box 3000, FIN-90 014 University of Oulu (Finland); Turunen, J. [Botany Division, Department of Biology, P.O. Box 3000, FIN-90 014 University of Oulu (Finland)

    2005-01-01

    The UV-B-absorbing compounds of herbarium specimens of 10 subarctic bryophyte species collected during the years 1926-1996 and available at the Botanical Museum, University of Oulu, were studied. We studied whether herbarium specimens reflect changes in the past radiation climate through their methanol-extractable compounds. The order of gametophytes based on the average amount of total compounds (sum of A{sub 280-320nm}) per mass from the lowest to the highest was Polytrichum commune, Pleurozium schreberi, Hylocomium splendens, Sphagnum angustifolium, Dicranum scoparium, Funaria hygrometrica, Sphagnum fuscum, Sphagnum warnstorfii, Sphagnum capillifolium and Polytrichastrum alpinum, and the amount of UV-B-absorbing compounds per specific surface area correlated with the summertime daily global radiation and latitude. P. alpinum, F. hygrometrica and three Sphagnum species seem to be good indicators for further studies. The amount of UV-B-absorbing compounds revealed no significant trends from the 1920s till the 1990s, with the exception of S. capillifolium, which showed a significant decreasing trend. - UV-B-absorbing compounds in subarctic herbarium bryophytes indicate the radiation climate of the collecting site and time.

  11. UV-absorbing compounds in subarctic herbarium bryophytes

    International Nuclear Information System (INIS)

    Huttunen, S.; Lappalainen, N.M.; Turunen, J.

    2005-01-01

    The UV-B-absorbing compounds of herbarium specimens of 10 subarctic bryophyte species collected during the years 1926-1996 and available at the Botanical Museum, University of Oulu, were studied. We studied whether herbarium specimens reflect changes in the past radiation climate through their methanol-extractable compounds. The order of gametophytes based on the average amount of total compounds (sum of A 280-320nm ) per mass from the lowest to the highest was Polytrichum commune, Pleurozium schreberi, Hylocomium splendens, Sphagnum angustifolium, Dicranum scoparium, Funaria hygrometrica, Sphagnum fuscum, Sphagnum warnstorfii, Sphagnum capillifolium and Polytrichastrum alpinum, and the amount of UV-B-absorbing compounds per specific surface area correlated with the summertime daily global radiation and latitude. P. alpinum, F. hygrometrica and three Sphagnum species seem to be good indicators for further studies. The amount of UV-B-absorbing compounds revealed no significant trends from the 1920s till the 1990s, with the exception of S. capillifolium, which showed a significant decreasing trend. - UV-B-absorbing compounds in subarctic herbarium bryophytes indicate the radiation climate of the collecting site and time

  12. Wideband aural acoustic absorbance predicts conductive hearing loss in children.

    Science.gov (United States)

    Keefe, Douglas H; Sanford, Chris A; Ellison, John C; Fitzpatrick, Denis F; Gorga, Michael P

    2012-12-01

    This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25, and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance, and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. Absorbance and conventional 0.226-kHz tympanograms were measured in children of age three to eight years with CHL and with normal hearing. Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 0.226-kHz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. Absorbance accurately predicted CHL in children and was more accurate than conventional 0.226-kHz tympanometry.

  13. Comparison of Five-Year Outcome of Percutaneous Coronary Intervention With Coronary Artery Bypass Grafting in Triple-Vessel Coronary Artery Disease (from the Coronary Revascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2).

    Science.gov (United States)

    Shiomi, Hiroki; Morimoto, Takeshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Tazaki, Junichi; Sakata, Ryuzo; Okabayashi, Hitoshi; Hanyu, Michiya; Shimamoto, Mitsuomi; Nishiwaki, Noboru; Komiya, Tatsuhiko; Kimura, Takeshi

    2015-07-01

    Studies evaluating long-term (≥5 years) outcomes of percutaneous coronary intervention (PCI) using drug-eluting stents compared with coronary artery bypass grafting (CABG) in patients with triple-vessel coronary artery disease (TVD) are still limited. We identified 2,978 patients with TVD (PCI: n = 1,824, CABG: n = 1,154) of 15,939 patients with first coronary revascularization enrolled in the Coronary Revascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2. The primary outcome measure in the present analysis was a composite of death, myocardial infarction (MI), and stroke. Median follow-up duration for the surviving patients was 1,973 days (interquartile range 1,700 to 2,244). The cumulative 5-year incidence of death/MI/stroke was significantly higher in the PCI group than in the CABG group (28.2% vs 24.0%, log-rank p = 0.006). After adjusting for confounders, the excess risk of PCI relative to CABG for death/MI/stroke remained significant (hazard ratio [HR] 1.38, 95% confidence interval [CI] 1.13 to 1.68, p = 0.002). The excess risks of PCI relative to CABG for all-cause death, MI, and any coronary revascularization were also significant (HR 1.38, 95% CI 1.10 to 1.74, p = 0.006; HR 2.81, 95% CI 1.69 to 4.66, p PCI and CABG groups (HR 0.88, 95% CI 0.61 to 1.26, p = 0.48). There were no interactions for the primary outcome measure between the mode of revascularization (PCI or CABG) and the subgroup factors such as age, diabetes, and Synergy Between PCI With Taxus and Cardiac Surgery score. In conclusion, CABG compared with PCI was associated with better long-term outcome in patients with TVD. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. The outcome of apical microsurgery using MTA as the root-end filling material: 2- to 6-year follow-up study.

    Science.gov (United States)

    Çalışkan, M K; Tekin, U; Kaval, M E; Solmaz, M C

    2016-03-01

    To evaluate the influence of various predictors on the healing outcome 2-6 years after apical microsurgery (AMS) using MTA as the root-end filling material. A total of 90 anterior teeth with asymptomatic persistent periradicular periodontitis of strictly endodontic origin that failed after either nonsurgical or surgical treatment were included. Surgery was completed under local anaesthesia using a standardized clinical protocol. Clinical and radiographic measures as well as the follow-up period were used to determine the healing outcome. For statistical analysis of the predictors, the outcome was dichotomized into healed cases and nonhealed cases. Odds ratios were calculated, and Pearson chi-square or Fisher's exact tests were used to analyse the data. Clinical and radiographic assessment of AMS revealed that 80% were healed, 14.4% were nonhealed, whilst 5.6% were judged to be uncertain. None of the various predictors investigated had a significant influence on the outcome of AMS. The results of this clinical study demonstrated that 80% of cases that received apical microsurgery healed when using MTA as the root-end filling material. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  15. Three-Year Outcomes of Bariatric Surgery vs Lifestyle Intervention for Type 2 Diabetes Mellitus Treatment: A Randomized Clinical Trial.

    Science.gov (United States)

    Courcoulas, Anita P; Belle, Steven H; Neiberg, Rebecca H; Pierson, Sheila K; Eagleton, Jessie K; Kalarchian, Melissa A; DeLany, James P; Lang, Wei; Jakicic, John M

    2015-10-01

    Questions remain about the role and durability of bariatric surgery for type 2 diabetes mellitus (T2DM). To compare the remission of T2DM following surgical and nonsurgical treatments. In this 3-arm randomized clinical trial conducted at the University of Pittsburgh Medical Center from October 1, 2009, to June 26, 2014, in Pittsburgh, Pennsylvania, outcomes were assessed 3 years after treating 61 obese participants aged 25 to 55 years with T2DM. Analysis was conducted with an intent-to-treat population. Participants were randomized to either an intensive lifestyle weight loss intervention for 1 year followed by a low-level lifestyle intervention for 2 years or surgical treatments (Roux-en-Y gastric bypass [RYGB] or laparoscopic adjustable gastric banding [LAGB]) followed by low-level lifestyle intervention in years 2 and 3. Primary end points were partial and complete T2DM remission and secondary end points included diabetes medications and weight change. Body mass index (calculated as weight in kilograms divided by height in meters squared) was less than 35 for 26 participants (43%), 50 (82%) were women, and 13 (21%) were African American. Mean (SD) values were 100.5 (13.7) kg for weight, 47.3 (6.6) years for age, 7.8% (1.9%) for hemoglobin A1c level, and 171.3 (72.5) mg/dL for fasting plasma glucose level. Partial or complete T2DM remission was achieved by 40% (n = 8) of RYGB, 29% (n = 6) of LAGB, and no intensive lifestyle weight loss intervention participants (P = .004). The use of diabetes medications was reduced more in the surgical groups than the lifestyle intervention-alone group, with 65% of RYGB, 33% of LAGB, and none of the intensive lifestyle weight loss intervention participants going from using insulin or oral medication at baseline to no medication at year 3 (P lifestyle treatment at 5.7% (2.4%) (P lifestyle intervention resulted in more disease remission than did lifestyle intervention alone. clinicaltrials.gov Identifier: NCT

  16. Q-switched Yb3+:YAG laser using plasmonic Cu2-xSe quantum dots as saturable absorbers

    Science.gov (United States)

    Wang, Yimeng; Zhan, Yi; Lee, Sooho; Wang, Li; Zhang, Xinping

    2018-04-01

    Cu2-xSe quantum dots (QDs) were synthesized by organometallic synthesis methods. Due to heavy self-doping, the Cu2-xSe QDs exhibit particle plasmon resonance in the near-infrared. Transient absorption spectroscopic investigation revealed strong nonlinear optical absorption and bleaching performance of the QDs under femtosecond pulse excitation, which enabled the Cu2-xSe QDs to be excellent saturable absorbers and applied in Q-switched or mode-locked lasers. A passively Q-switched Yb3+:YAG solid-state laser at 1.03 μm was achieved by coating Cu2-xSe QDs as saturable absorbers onto one of the output coupler of the V-shaped linear cavity.

  17. An ultra-broadband multilayered graphene absorber

    KAUST Repository

    Amin, Muhammad

    2013-01-01

    An ultra-broadband multilayered graphene absorber operating at terahertz (THz) frequencies is proposed. The absorber design makes use of three mechanisms: (i) The graphene layers are asymmetrically patterned to support higher order surface plasmon modes that destructively interfere with the dipolar mode and generate electromagnetically induced absorption. (ii) The patterned graphene layers biased at different gate voltages backedup with dielectric substrates are stacked on top of each other. The resulting absorber is polarization dependent but has an ultra-broadband of operation. (iii) Graphene\\'s damping factor is increased by lowering its electron mobility to 1000cm 2=Vs. Indeed, numerical experiments demonstrate that with only three layers, bandwidth of 90% absorption can be extended upto 7THz, which is drastically larger than only few THz of bandwidth that can be achieved with existing metallic/graphene absorbers. © 2013 Optical Society of America.

  18. The Discover artificial disc replacement versus fusion in cervical radiculopathy--a randomized controlled outcome trial with 2-year follow-up.

    Science.gov (United States)

    Skeppholm, Martin; Lindgren, Lars; Henriques, Thomas; Vavruch, Ludek; Löfgren, Håkan; Olerud, Claes

    2015-06-01

    Several previous studies comparing artificial disc replacement (ADR) and fusion have been conducted with cautiously positive results in favor of ADR. This study is not, in contrast to most previous studies, an investigational device exemption study required by the Food and Drug Administration for approval to market the product in the United States. This study was partially funded with unrestricted institutional research grants by the company marketing the artificial disc used in this study. To compare outcomes between the concepts of an artificial disc to treatment with anterior cervical decompression and fusion (ACDF) and to register complications associated to the two treatments during a follow-up time of 2 years. This is a randomized controlled multicenter trial, including three spine centers in Sweden. The study included patients seeking care for cervical radiculopathy who fulfilled inclusion criteria. In total, 153 patients were included. Self-assessment with Neck Disability Index (NDI) as a primary outcome variable and EQ-5D and visual analog scale as secondary outcome variables. Patients were randomly allocated to either treatment with the Depuy Discover artificial disc or fusion with iliac crest bone graft and plating. Randomization was blinded to both patient and caregivers until time for implantation. Adverse events, complications, and revision surgery were registered as well as loss of follow-up. Data were available in 137 (91%) of the included and initially treated patients. Both groups improved significantly after surgery. NDI changed from 63.1 to 39.8 in an intention-to-treat analysis. No statistically significant difference between the ADR and the ACDF groups could be demonstrated with NDI values of 39.1 and 40.1, respectively. Nor in secondary outcome measures (EQ-5D and visual analog scale) could any statistically significant differences be demonstrated between the groups. Nine patients in the ADR group and three in the fusion group underwent

  19. Early MRI in term infants with perinatal hypoxic–ischaemic brain injury: Interobserver agreement and MRI predictors of outcome at 2 years

    International Nuclear Information System (INIS)

    Goergen, S.K.; Ang, H.; Wong, F.; Carse, E.A.; Charlton, M.; Evans, R.; Whiteley, G.; Clark, J.; Shipp, D.; Jolley, D.; Paul, E.; Cheong, J.L.Y.

    2014-01-01

    Aim: To compare diffusion-weighted imaging (DWI) and non-DWI magnetic resonance imaging (MRI), proton MR spectroscopy (1H-MRS), and clinical biomarkers for prediction of 2 year developmental outcome in term infants with perinatal hypoxic–ischaemic encephalopathy (HIE). Materials and methods: Nineteen infants ≥36 weeks gestation with HIE were recruited and MRI performed day 3–7 (mean = 5). MRI was scored independently by three radiologists using a standardized scoring system. Lactate-to-N-acetylaspartate ratio (Lac:NAA) in the lentiform nucleus was calculated. Developmental assessment was performed at 2 years using the Bayley Scales of Infant and Toddler Development (BSID-III). Interobserver agreement about abnormality in 10 brain regions was measured. Univariate analysis was performed to determine variables associated with adverse outcome (i.e., death or Bayley score for any domain <70). Results: Good interobserver agreement (kappa = 0.61–0.69) on scores for DWI was obtained for the cortex, putamen, and brainstem, but not for any region on non-DWI. A significant association was found between outcome and Lac:NAA (p < 0.003) and DWI scores for lentiform nucleus, thalamus, cortex, posterior limb of the internal capsule (PLIC), and paracentral white matter (p = 0.001–0.013), but for non-DWI score only in the vermis or brainstem. A combination of Lac:NAA ≥0.25 or DWI/apparent diffusion coefficient (ADC) signal abnormality in the PLIC had 100% specificity and sensitivity for poor outcome. Conclusion: Interobserver agreement for non-DWI performed during the first week is poor. Agreement by three radiologists about the presence of abnormal signal within the PLIC on ADC/DWI images or elevation of Lac:NAA above 0.25 improved sensitivity without reducing the prognostic specificity of MRS in the 19 patients, but this requires validation in a larger group of infants with HIE who have been treated with hypothermia

  20. Plumbing system shock absorbers as a source of Legionella pneumophila.

    Science.gov (United States)

    Memish, Z A; Oxley, C; Contant, J; Garber, G E

    1992-12-01

    Water distribution systems have been demonstrated to be a major source of nosocomial legionellosis. We describe an outbreak in our institution in which a novel source of Legionella pneumophila was identified in the plumbing system. After an outbreak of 10 cases of legionellosis in our hospital, recommended measures including superheating of the hot water to 80 degrees C, hyperchlorination to 2 ppm, and flushing resulted in no new cases in the following 5 years. Recently, despite these control measures, three new cases occurred. Surveillance cultures of shower heads and water tanks were negative; cultures of tap water samples remained positive. This prompted a search for another reservoir. Shock absorbers installed within water pipes to decrease noise were suspected. One hundred twenty-five shock absorbers were removed and cultured. A total of 13 (10%) yielded heavy growth of L. pneumophila (serogroup 1). Since their removal, no new cases have been found and the percentage of positive results of random tap water culture has dropped from 20% to 5%. This is the first report that identifies shock absorbers as a possible reservoir for L. pneumophila. We recommend that institutions with endemic legionellosis assess the water system for possible removal of shock absorbers.

  1. Measurements of light-absorbing particles on the glaciers in the Cordillera Blanca, Peru

    Science.gov (United States)

    Schmitt, C. G.; All, J. D.; Schwarz, J. P.; Arnott, W. P.; Cole, R. J.; Lapham, E.; Celestian, A.

    2015-02-01

    Glaciers in the tropical Andes have been rapidly losing mass since the 1970s. In addition to the documented increase in temperature, increases in light-absorbing particles deposited on glaciers could be contributing to the observed glacier loss. Here we report on measurements of light-absorbing particles sampled from glaciers during three surveys in the Cordillera Blanca Mountains in Peru. During three research expeditions in the dry seasons (May-August) of 2011, 2012 and 2013, 240 snow samples were collected from 15 mountain peaks over altitudes ranging from 4800 to nearly 6800 m. Several mountains were sampled each of the 3 years and some mountains were sampled multiple times during the same year. Collected snow samples were melted and filtered in the field then later analyzed using the Light Absorption Heating Method (LAHM), a new technique that measures the ability of particles on filters to absorb visible light. LAHM results have been calibrated using filters with known amounts of fullerene soot, a common industrial surrogate for black carbon (BC). As sample filters often contain dust in addition to BC, results are presented in terms of effective black carbon (eBC). During the 2013 survey, snow samples were collected and kept frozen for analysis with a Single Particle Soot Photometer (SP2). Calculated eBC mass from the LAHM analysis and the SP2 refractory black carbon (rBC) results were well correlated (r2 = 0.92). These results indicate that a substantial portion of the light-absorbing particles in the more polluted regions were likely BC. The 3 years of data show that glaciers in the Cordillera Blanca Mountains close to human population centers have substantially higher levels of eBC (as high as 70 ng g-1) than remote glaciers (as low as 2.0 ng g-1 eBC), indicating that population centers can influence local glaciers by sourcing BC.

  2. GEANT 4.8.2, 9.2 and 9.4 simulations versus experimental proton energy loss in thick absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Evseev, Ivan; Schelin, Hugo R.; Ahmann, Francielle; Milhoretto, Edney; Paschuk, Sergei A., E-mail: evseev@utfpr.edu.b, E-mail: schelin@utfpr.edu.b, E-mail: sergei@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Yevseyeva, Olga; Assis, Joaquim T. de; Ievsieieva, Ievgeniia, E-mail: yevseveva@iprj.uerj.b, E-mail: joaquim@iprj.uerj.b [Instituto Politecnico do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil). Dept. de Modelagem Computacional; Hormaza, Joel M., E-mail: jmesa@ibb.unesp.b [Universidade Estadual Paulista (IBB/UNESP), Botucatu, SP (Brazil). Inst. de Biociencias; Diaz, Katherin S. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, Havana (Cuba); Lopes, Ricardo T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Monte Carlo simulations are a powerful tool to estimate the proton energy loss and straggling in medical applications. The physics of proton interaction with matter for thick absorbers (like a human body) has a well-established theory for the so-called Bethe-Bloch domain, and the basic principles of Monte Carlo simulation for such processes are well known since the middle of the past century. However, in spite of GEANT4 has been validated against proton stopping powers from the NIST PSTAR, the evolution of the code leads to some result instability within the various code releases. In this work, we present the recent results for the comparison of our GEANT4 simulations against experimental proton energy loss for some thick absorbers. All the simulations were performed using the GEANT4 Hadrontherapy Advanced Example. The GEANT4 versions 4.8.2, 4.9.2, and 4.9.4 were tested with different simulation parameters, such as varied cut values. In addition to the Standard model, some other models for the electromagnetic processes from the GEANT4 Low Energy Extension Pack were tested as well. Experimental data were taken from for polyethylene, and from for aluminum and gold absorbers. The theoretical predictions for the spectra were calculated using the self-consistent Gaussian solution of the Boltzmann kinetic equation in the Fokker-Plank form. In order to compare the GEANT4 simulations with other popular codes, the same spectra were simulated by TRIM/SRIM2011 and MCNPX2.4.0. The simultaneous comparison of the results obtained for different materials at various initial proton energies were done using the reduced calibration curve approach. (author)

  3. Roof Integrated Solar Absorbers: The Measured Performance of ''Invisible'' Solar Collectors: Preprint

    International Nuclear Information System (INIS)

    Colon, C. J.; Merrigan, T.

    2001-01-01

    The Florida Solar Energy Center (FSEC), with the support of the National Renewable Energy Laboratory, has investigated the thermal performance of solar absorbers that are an integral, yet indistinguishable, part of a building's roof. The first roof-integrated solar absorber (RISA) system was retrofitted into FSEC's Flexible Roof Facility in Cocoa, Florida, in September 1998. This ''proof-of-concept'' system uses the asphalt shingle roof surface and the plywood decking under the shingles as an unglazed solar absorber. Data was gathered for a one-year period on the system performance. In Phase 2, two more RISA prototypes were constructed and submitted for testing. The first used the asphalt shingles on the roof surface with the tubing mounted on the underside of the plywood decking. The second prototype used metal roofing panels over a plywood substrate and placed the polymer tubing between the plywood decking and the metal roofing. This paper takes a first look at the thermal performance results for the ''invisible'' solar absorbers that use the actual roof surface of a building for solar heat collection

  4. Progress on the MICE Liquid Absorber Cooling and Cryogenic Distribution System

    International Nuclear Information System (INIS)

    Green, M.A.; Baynham, E.; Bradshaw, T.; Drumm, P.; Ivanyushenkov, Y.; Ishimoto, S.; Cummings, M.A.C.; Lau, W.W.; Yang, S.Q.

    2005-01-01

    This report describes the progress made on the design of the cryogenic cooling system for the liquid absorber for the international Muon Ionization Cooling Experiment (MICE). The absorber consists of a 20.7-liter vessel that contains liquid hydrogen (1.48 kg at 20.3 K) or liquid helium (2.59 kg at 4.2 K). The liquid cryogen vessel is located within the warm bore of the focusing magnet for the MICE. The purpose of the magnet is to provide a low beam beta region within the absorber. For safety reasons, the vacuum vessel for the hydrogen absorber is separated from the vacuum vessel for the superconducting magnet and the vacuum that surrounds the RF cavities or the detector. The absorber thin windows separate the liquid in the absorber from the absorber vacuum. The absorber vacuum vessel also has thin windows that separate the absorber vacuum space from adjacent vacuum spaces. Because the muon beam in MICE is of low intensity, there is no beam heating in the absorber. The absorber can use a single 4 K cooler to cool either liquid helium or liquid hydrogen within the absorber

  5. Absorbed dose rate meter for β-ray

    International Nuclear Information System (INIS)

    Bingo, K.

    1977-01-01

    The absorbed dose of β-ray depends on the energy of β-rays and the epidermal thickness of tissue in interest. In order to measure the absorbed dose rate at the interested tissue directly, the ratio of counting rate to absorbed dose should be constant independent of β-ray energy. In this purpose, a thin plastic scintillator was used as a detector with a single channel analyzer. The pulse height distribution, obtained using the scintillator whose thickness is less than the range of β-rays, shows a peak at a particular pulse height depending on the thickness of scintillator used. This means an increase of the number of pulses at lower pulse height. The lower level of discrimination and window width of the single channel analyzer are chosen according to the epidermal thickness of the tissue. In the experiment, scintillators of 0.5, 1, 2, 3, 5 and 10 mm thick were tested. It was found that desirable pulse height distribution, to obtain a constant dose sensitivity, could be obtained using the 2 mm thick scintillator. The sensitivity of the absorbed dose rate meter is constant within +-15% for β-ray with maximum energy from 0.4 to 3.5 MeV, when the absorbed dose rate for skin (epidermal thickness 7mg/cm 2 ) is measured. In order to measure the dose rate for a hand (epithermal thickness 40mg/cm 2 ) the lower level of discrimination is changed to be higher and at the same time the window width is also changed. Combining these techniques, one can get an absorbed dose rate meter for the tissue dose of various thickness, which has the constant dose sensitivity within +-15% for β-rays with maximum energy from 0.4 to 3.5 MeV

  6. Limitations of Cs3Bi2I9 as lead-free photovoltaic absorber materials.

    Science.gov (United States)

    Ghosh, Biplab; Wu, Bo; Mulmudi, Hemant Kumar; Guet, Claude; Weber, Klaus; Sum, Tze Chien; Mhaisalkar, Subodh G; Mathews, Nripan

    2018-01-17

    Lead (Pb) halide perovskites have attracted tremendous attention in recent years due to their rich optoelectronic properties, which have resulted in more than 22% power conversion efficient photovoltaics. Nevertheless, Pb-metal toxicity remains a huge hurdle for extensive applications of these compounds. Thus, alternative compounds with similar optoelectronic properties need to be developed. Bismuth possesses similar electronic structure as that of lead with the presence of ns2 electrons that exhibit rich structural variety as well as interesting optical and electronic properties. Herein, we critically assess Cs3Bi2I9 as a candidate for thin-film solar cell absorber. Despite a reasonable optical bandgap (~2eV) and absorption coefficient, the power conversion efficiency of the Cs3Bi2I9 mesoscopic solar cells was found to be severely lacking, limited by poor photocurrent density. The efficiency of the Cs3Bi2I9 solar cell can be slightly improved by changing the stoichiometry of the precursor solutions. We have investigated the possible reasons behind the poor performance of Cs3Bi2I9 by transient absorption and luminescence spectroscopy. Comparison between thin-films and single crystals highlights the presence of intrinsic defects in thin-films which act as nonradiative recombination centers.

  7. One-year outcomes of AquaLase cataract surgery.

    Science.gov (United States)

    Yoo, Sonia H; Bhatt, Anand B

    2007-01-01

    The authors report surgical experience and clinical outcomes up to 1 year postoperatively in patients who underwent cataract surgery with the AquaLase liquefaction device (Alcon Laboratories, Fort Worth, TX). The device is a handpiece option for use with Alcon's Infiniti Vision System that uses heated balanced saline solution micropulses to liquefy lenticular material. Twenty-seven eyes of 23 patients underwent cataract extraction with the use of the AquaLase liquefaction device. The average age of participants was 68 years, and the average nuclear sclerotic grade was 1.96 on a 4-point scale. Outcomes were judged by metrics such as visual acuity, inflammation, endothelial cell count, and postoperative posterior capsule opacification. At 30 days postoperatively, 78% of eyes had a best-corrected visual acuity of 20/20. Visual acuity was 20/25 or better 1 year postoperatively in 88% of patients without complications except conversion to ultrasound phacoemulsification for two dense cataracts.

  8. Variability in the Initial Costs of Care and One-Year Outcomes of Observation Services

    Directory of Open Access Journals (Sweden)

    Abbass, Ibrahim

    2015-05-01

    Full Text Available Introduction: The use of observation units (OUs following emergency departments (ED visits as a model of care has increased exponentially in the last decade. About one-third of U.S. hospitals now have OUs within their facilities. While their use is associated with lower costs and comparable level of care compared to inpatient units, there is a wide variation in OUs characteristics and operational procedures. The objective of this research was to explore the variability in the initial costs of care of placing patients with non-specific chest pain in observation units (OUs and the one-year outcomes. Methods: The author retrospectively investigated medical insurance claims of 22,962 privately insured patients (2009-2011 admitted to 41 OUs. Outcomes included the one-year chest pain/cardiovascular related costs and primary and secondary outcomes. Primary outcomes included myocardial infarction, congestive heart failure, stroke or cardiac arrest, while secondary outcomes included revascularization procedures, ED revisits for angina pectoris or chest pain and hospitalization due to cardiovascular diseases. The author aggregated the adjusted costs and prevalence rates of outcomes for patients over OUs, and computed the weighted coefficients of variation (WCV to compare variations across OUs. Results: There was minimal variability in the initial costs of care (WCV=2.2%, while the author noticed greater variability in the outcomes. Greater variability were associated with the adjusted cardiovascular-related costs of medical services (WCV=17.6% followed by the adjusted prevalence odds ratio of patients experiencing primary outcomes (WCV=16.3% and secondary outcomes (WCV=10%. Conclusion: Higher variability in the outcomes suggests the need for more standardization of the observation services for chest pain patients. [West J Emerg Med. 2015;16(3:395–400.

  9. Outcomes of childhood asthma to the age of 50 years.

    Science.gov (United States)

    Tai, Andrew; Tran, Haily; Roberts, Mary; Clarke, Nadeene; Gibson, Anne-Marie; Vidmar, Suzanna; Wilson, John; Robertson, Colin F

    2014-06-01

    In 1964, The Melbourne Asthma Study was established to describe the spectrum and natural history of childhood asthma. To describe the clinical and lung function outcome of childhood asthma to the age of 50 years. Subjects were invited to complete an interviewer-administered questionnaire, skin prick testing, and measurement of lung function from the age of 7 years to the age of 50 years at 7-year intervals. Of 458 survivors (from the original 484 subjects at recruitment), 346 subjects (76%) participated, of whom, 197 completed lung function measurement. Asthma remission at the age of 50 years was 64% in those with wheezy bronchitis, 47% for those with persistent asthma, and 15% for those with severe asthma in childhood. Multivariable analysis identified severe asthma in childhood (odds ratio [OR] 11.9 [95% CI, 3.4-41.8]), female sex (OR 2.0 [95% CI, 1.1-3.6]), and childhood hay fever (OR 2.0 [95% CI, 1.0-4.0]) as risk factors for "current asthma" at age 50 years. There was no evidence of a difference in the rate of decline in FEV1 (mL/y, 95% CI) between the severe asthma group (15 mL/y [95% CI, 9-22 mL/y]) and all the other recruitment groups: control (16 mL/y [95% CI, 12-20 mL/y]), mild wheezy bronchitis (14 mL/y [95% CI, 8-19 mL/y]), wheezy bronchitis (16 mL/y [95% CI, 11-20 mL/y]), and persistent asthma (19 mL/y [95% CI, 13-24 mL/y]). The clinical and lung function outcome in adult life is strongly determined by asthma severity in childhood. The reduced lung function seen in adults is established in childhood and does not appear to decline more rapidly in adult years despite continuing symptoms. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  10. Outcome and Structural Integrity of Rotator Cuff after Arthroscopic Treatment of Large and Massive Tears with Double Row Technique: A 2-Year Followup

    Directory of Open Access Journals (Sweden)

    Ignacio Carbonel

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to evaluate the functional outcome and the tendon healing after arthroscopic double row rotator cuff repair of large and massive rotator cuff tears. Methods. 82 patients with a full-thickness large and massive rotator cuff tear underwent arthroscopic repair with double row technique. Results were evaluated by use of the UCLA, ASES, and Constant questionnaires, the Shoulder Strength Index (SSI, and range of motion. Follow-up time was 2 years. Magnetic resonance imaging (MRI studies were performed on each shoulder preoperatively and 2 years after repair. Results. 100% of the patients were followed up. UCLA, ASES, and Constant questionnaires showed significant improvement compared with preoperatively (P<0.001. Range of motion and SSI in flexion, abduction, and internal and external rotation also showed significant improvement (P<0.001. MRI studies showed 24 cases of tear after repair (29%. Only 8 cases were a full-thickness tear. Conclusions. At two years of followup, in large and massive rotator cuff tears, an arthroscopic double row rotator cuff repair technique produces an excellent functional outcome and structural integrity.

  11. An overview of the development, testing, and application of composite absorbers

    International Nuclear Information System (INIS)

    Sebesta, F.; John, J.

    1995-02-01

    Although inorganic exchangers offer many advantages for removing selected elements from radioactive waste streams, few of these materials are suitable for use in packed-bed columns. We review various adaptations of inorganic exchangers for use in columns, which include granular forms of the intrinsic absorbers, absorber compounds supported on other materials, and composite absorbers that use organic or inorganic binders. An organic binding polymer of polyacrylonitrile (PAN), developed at the Czech Technical University, has been demonstrated to offer advantages. We describe general methods for preparing inorganic exchange materials, which then are incorporated into PAN-based composites. Such PAN composites have been used to remove selected radionuclides from a variety of liquid waste streams. Sixteen different PAN composites were prepared for testing at Los Alamos National Laboratory (LANL) as part of an evaluation of potential partitioning agents for remediating the liquid waste in underground storage tanks at the Hanford site near Richland, Washington. Our collaboration with LANL is expected to continue for another 2 years

  12. An overview of the development, testing, and application of composite absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Sebesta, F. [Czech Technical Univ., Brehova (Czech Republic); John, J. [Los Alamos National Lab., NM (United States)

    1995-02-01

    Although inorganic exchangers offer many advantages for removing selected elements from radioactive waste streams, few of these materials are suitable for use in packed-bed columns. We review various adaptations of inorganic exchangers for use in columns, which include granular forms of the intrinsic absorbers, absorber compounds supported on other materials, and composite absorbers that use organic or inorganic binders. An organic binding polymer of polyacrylonitrile (PAN), developed at the Czech Technical University, has been demonstrated to offer advantages. We describe general methods for preparing inorganic exchange materials, which then are incorporated into PAN-based composites. Such PAN composites have been used to remove selected radionuclides from a variety of liquid waste streams. Sixteen different PAN composites were prepared for testing at Los Alamos National Laboratory (LANL) as part of an evaluation of potential partitioning agents for remediating the liquid waste in underground storage tanks at the Hanford site near Richland, Washington. Our collaboration with LANL is expected to continue for another 2 years.

  13. Absorbant materials

    International Nuclear Information System (INIS)

    Quetier, Monique.

    1978-11-01

    Absorbants play a very important part in the nuclear industry. They serve for the control, shut-down and neutron shielding of reactors and increase the capacity of spent fuel storage pools and of special transport containers. This paper surveys the usual absorbant materials, means of obtainment, their essential characteristics relating to their use and their behaviour under neutron irradiation [fr

  14. Improving Phytoremediation of Oil Spills through Organic Absorbents

    Science.gov (United States)

    Xie, W.

    2017-12-01

    Every year, oil spills around the world contaminate the environment and cost billions of dollars to clean up. Phytoremediation is a current technology for recovering environments contaminated by harmful substances, such as oil, that utilizes plants' capabilities to concentrate and metabolize the contaminants. Ranunculus, or the buttercup, has raised interest in the field of phytoremediation, being reported to grow in waste environments including municipal waste disposals. My project confirmed Ranunculus to be a suitable plant for phytoremediation. However, the Ranunculus plants throughout experiments showed a limited tolerance for oil concentration, causing the plant to wilt, thus ending the phytoremediation process. To overcome this problem, my project explored the combination of organic oil absorbents and phytoremediation. Oil absorbents can quickly fix the spilled oil in place and prevent it from further migration. In addition, and most importantly, the initial free oil concentration in contact with the roots is thus effectively decreased, which is essential for the plants to survive. Typha(cattail) inflorescence, saw dust, cotton and a commercial polymer were tested for oil absorption and Typha was deemed superior, being highly oil absorbent, inexpensive, organic and hydrophobic. Further experiments were undertaken in a small outdoor space and in the UBC Horticulture greenhouse during the winter season over the course of one year. The experiments were set up to both determine the most suitable plant for phytoremediation and test the impact of using Typha inflorescence as an absorbent. For each plant, there were three pots with Typha inflorescence and oil, with oil but no Typha inflorescence and without either. In order to measure the benefit quantitatively, naturally occurring electrical currents of the metabolic process common in phytoremediation was used as an indicator for phytoremediative activity. The main findings of the experiments were: 1. Adding Typha

  15. Three-year Treatment Outcomes in the Ahmed Baerveldt Comparison Study

    Science.gov (United States)

    Barton, Keith; Feuer, William J; Budenz, Donald L; Schiffman, Joyce; Costa, Vital P.; Godfrey, David G.; Buys, Yvonne M.

    2014-01-01

    Purpose To compare three year outcomes and complications of the Ahmed FP7 Glaucoma Valve (AGV) and Baerveldt 101–350 Glaucoma Implant (BGI) for the treatment of refractory glaucoma. Design Multicenter randomized controlled clinical trial. Participants 276 patients; 143 in the AGV group and 133 in the BGI group. Methods Patients aged 18–85 years with refractory glaucoma and intraocular pressures (IOPs) ≥18 mmHg in whom an aqueous shunt was planned were randomized to either an AGV or a BGI. Main Outcome Measures IOP, visual acuity, supplemental medical therapy, complications, and failure (IOP > 21 mmHg or not reduced by 20% from baseline, IOP ≤ 5 mmHg, reoperation for glaucoma or removal of implant, or loss of light perception vision). Results At 3 years, IOP (mean ± standard deviation) (SD) was 14.3 ± 4.7 mmHg (AGV group) and 13.1 ± 4.5 mmHg (BGI group) (p = 0.086) on 2.0 ± 1.4 and 1.5 ± 1.4 glaucoma medications respectively (p = 0.020). The cumulative probabilities of failure were 31.3% (standard error = 4.0%) (SE) (AGV) and 32.3% (4.2%) (BGI) (p = 0.99). Postoperative complications associated with reoperation or vision loss of ≥ 2 Snellen lines occurred in 24 patients (22%) (AGV) and 38 patients (36%) (BGI) (p = 0.035). The mean change in the Logarithm of the Minimum Angle of Resolution visual acuity (logMAR VA) at 3 years was similar (AGV: 0.21 ± 0.88, BGI: 0.26 ± 0.74) in the two treatment groups at 3 years (p=0.66). The cumulative proportion of patients (SE) undergoing reoperation for glaucoma prior to the three year postoperative time point was 14.5% (3.0%) in the AGV group compared to 7.6% (2.4%) in the BGI group (p=0.053, log-rank). The relative risk of reoperation for glaucoma in the AGV group was 2.1 times that of the BGI group (95% Confidence Interval:1.0–4.8, p=0.045; Cox proportional hazards regression). Conclusions AGV implantation was associated with the need for significantly greater adjunctive medication to achieve equal success

  16. The Cooling of a Liquid Absorber using a Small Cooler

    International Nuclear Information System (INIS)

    Baynham, D.E.; Bradshaw, T.W.; Green, M.A.; Ishimoto, S.; Liggins, N.

    2005-01-01

    This report discusses the use of small cryogenic coolers for cooling the Muon Ionization Cooling Experiment (MICE) liquid cryogen absorbers. Since the absorber must be able contain liquid helium as well liquid hydrogen, the characteristics of the available 4.2 K coolers are used here. The issues associated with connecting two-stage coolers to liquid absorbers are discussed. The projected heat flows into an absorber and the cool-down of the absorbers using the cooler are presented. The warm-up of the absorber is discussed. Special hydrogen safety issues that may result from the use of a cooler on the absorbers are also discussed

  17. Chemically vapor-deposited ZrB2 as a selective solar absorber

    International Nuclear Information System (INIS)

    Randich, E.; Allred, D.D.

    1981-01-01

    Coatings of ZrB 2 and TiB 2 for photothermal solar absorber applications were prepared using chemical vapor deposition (CVD) techniques. Oxidation tests suggest a maximum temperature limit for air exposure of 600 K for TiB 2 and 800 K for ZrB 2 . Both materials exhibit innate spectral selectivity with an emittance at 375 K ranging from 0.06 to 0.09, a solar absorptance for ZrB 2 ranging from 0.67 to 0.77 and a solar absorptance for TiB 2 ranging from 0.46 to 0.59. ZrB 2 has better solar selectivity and more desirable oxidation behavior than TiB 2 . A 0.071 μm antireflection coating of Si 3 N 4 deposited onto the ZrB 2 coating leads to an increase in absorptance from 0.77 to 0.93, while the emittance remains unchanged. (Auth.)

  18. Outcomes of basilar artery occlusion in patients aged 75 years or older in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Vergouwen, Mervyn D I; Compter, Annette; Tanne, David; Engelter, Stefan T; Audebert, Heinrich; Thijs, Vincent; de Freitas, Gabriel; Algra, Ale; Jaap Kappelle, L; Schonewille, Wouter J

    2012-11-01

    Patients with an acute basilar artery occlusion (BAO) have a high risk of long-lasting disability and death. Only limited data are available on functional outcome in elderly patients with BAO. Using data from the Basilar Artery International Cooperation Study, we aimed to determine outcomes in patients ≥75 years. Primary outcome measure was poor functional outcome (modified Rankin scale score 4-6). Secondary outcomes were death, insufficient vessel recanalization (defined as thrombolysis in myocardial infarction score 0-1) and symptomatic intracranial hemorrhage (SICH). Patients were divided into four age-groups, based on quartiles: 18-54, 55-64, 65-74, and ≥75 years. Outcomes were compared between patients ≥75 years and patients aged 18-54 years. Risk ratios with corresponding 95 % confidence intervals (CI) were calculated and Poisson regression analyses were performed to calculate adjusted risk ratios (aRR). We included 619 patients [18-54 years n = 153 (25 %), 55-64 years n = 133 (21 %), 65-74 years n = 171 (28 %), and ≥75 years n = 162 (26 %)]. Compared with patients aged 18-54 years, patients ≥75 years were at increased risk of poor functional outcome [aRR 1.33 (1.14-1.55)] and death [aRR 2.47 (1.75-3.51)]. Nevertheless, 35/162 (22 %, 95 % CI 15-28 %) of patients ≥75 years had good functional outcome. No significant differences between age groups were observed for recanalization rate and incidence of SICH. Although patients ≥75 years with BAO have an increased risk of poor outcome compared with younger patients, a substantial group of patients ≥75 years survives with a good functional outcome.

  19. Design of a nonlinear torsional vibration absorber

    Science.gov (United States)

    Tahir, Ammaar Bin

    Tuned mass dampers (TMD) utilizing linear spring mechanisms to mitigate destructive vibrations are commonly used in practice. A TMD is usually tuned for a specific resonant frequency or an operating frequency of a system. Recently, nonlinear vibration absorbers attracted attention of researchers due to some potential advantages they possess over the TMDs. The nonlinear vibration absorber, or the nonlinear energy sink (NES), has an advantage of being effective over a broad range of excitation frequencies, which makes it more suitable for systems with several resonant frequencies, or for a system with varying excitation frequency. Vibration dissipation mechanism in an NES is passive and ensures that there is no energy backflow to the primary system. In this study, an experimental setup of a rotational system has been designed for validation of the concept of nonlinear torsional vibration absorber with geometrically induced cubic stiffness nonlinearity. Dimensions of the primary system have been optimized so as to get the first natural frequency of the system to be fairly low. This was done in order to excite the dynamic system for torsional vibration response by the available motor. Experiments have been performed to obtain the modal parameters of the system. Based on the obtained modal parameters, the design optimization of the nonlinear torsional vibration absorber was carried out using an equivalent 2-DOF modal model. The optimality criterion was chosen to be maximization of energy dissipation in the nonlinear absorber attached to the equivalent 2-DOF system. The optimized design parameters of the nonlinear absorber were tested on the original 5-DOF system numerically. A comparison was made between the performance of linear and nonlinear absorbers using the numerical models. The comparison showed the superiority of the nonlinear absorber over its linear counterpart for the given set of primary system parameters as the vibration energy dissipation in the former is

  20. Absorber for terahertz radiation management

    Science.gov (United States)

    Biallas, George Herman; Apeldoorn, Cornelis; Williams, Gwyn P.; Benson, Stephen V.; Shinn, Michelle D.; Heckman, John D.

    2015-12-08

    A method and apparatus for minimizing the degradation of power in a free electron laser (FEL) generating terahertz (THz) radiation. The method includes inserting an absorber ring in the FEL beam path for absorbing any irregular THz radiation and thus minimizes the degradation of downstream optics and the resulting degradation of the FEL output power. The absorber ring includes an upstream side, a downstream side, and a plurality of wedges spaced radially around the absorber ring. The wedges form a scallop-like feature on the innermost edges of the absorber ring that acts as an apodizer, stopping diffractive focusing of the THz radiation that is not intercepted by the absorber. Spacing between the scallop-like features and the shape of the features approximates the Bartlett apodization function. The absorber ring provides a smooth intensity distribution, rather than one that is peaked on-center, thereby eliminating minor distortion downstream of the absorber.

  1. Cu(InGa)Se{sub 2} absorber formation by in-situ, low-temperature annealing of co-evaporated bilayer (InGa){sub 2}Se{sub 3}/CuSe precursors

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Kyeongchan; Kim, Woo Kyoung, E-mail: wkim@ynu.ac.kr

    2015-12-01

    Chalcopyrite Cu(InGa)Se{sub 2} (CIGS) absorbers were fabricated by the formation of bilayer stacked glass/Mo/(InGa){sub 2}Se{sub 3}/CuSe precursors followed by in-situ thermal annealing at 450 °C for approximately 10 min in a vacuum evaporator. The material properties (e.g., crystal orientation, compositional depth profile, and overall composition) and device performance of the resulting CIGS absorbers were compared with those of the CIGS absorbers formed by conventional 1-stage and 3-stage CIGS formation processes at a similar temperature. X-ray diffraction confirmed that the 1-stage co-evaporation and in-situ annealing of the bilayer precursor produced a polycrystalline CIGS absorber without a specific texture, whereas the CIGS absorber formed by the 3-stage process showed a highly (220) preferred orientation. Secondary ion mass spectrometry revealed Ga accumulation at the bottom of CIGS formed by in-situ annealing of the bilayer precursors. The cell efficiency of the device with the CIGS absorber formed by the in-situ, low-temperature (450 °C) annealing of bilayer stacked glass/Mo/(InGa){sub 2}Se{sub 3}/CuSe precursors was comparable to that produced by the conventional 3-stage process at a similar temperature. - Highlights: • Annealing of (InGa){sub 2}Se{sub 3}/CuSe precursors was compared with coevaporation process. • In-situ annealing of (InGa){sub 2}Se{sub 3}/CuSe precursors at 450 °C produced about 9% solar cell. • Ga profile within Cu(InGa)Se{sub 2} depended on process profile during co-evaporation.

  2. Should Women Younger Than 40 Years of Age With Invasive Breast Cancer Have a Mastectomy?: 15-Year Outcomes in a Population-Based Cohort

    International Nuclear Information System (INIS)

    Cao, Jeffrey Q.; Truong, Pauline T.; Olivotto, Ivo A.; Olson, Robert; Coulombe, Genevieve; Keyes, Mira; Weir, Lorna; Gelmon, Karen; Bernstein, Vanessa; Woods, Ryan; Speers, Caroline; Tyldesley, Scott

    2014-01-01

    Purpose: Optimal local management for young women with early-stage breast cancer remains controversial. This study examined 15-year outcomes among women younger than 40 years treated with breast-conserving surgery plus whole-breast radiation therapy (BCT) compared with those treated with modified radical mastectomy (MRM). Methods and Materials: Women aged 20 to 39 years with early-stage breast cancer diagnosed between 1989 and 2003 were identified in a population-based database. Primary outcomes of breast cancer–specific survival (BCSS), overall survival (OS) and secondary outcomes of local relapse–free survival (LRFS), locoregional relapse–free survival (LRRFS), and distant relapse–free survival (DRFS) were calculated using Kaplan-Meier methods and compared between BCT and MRM cohorts using log-rank tests. A planned subgroup analysis was performed on patients considered “ideal” for BCT (ie, T1N0, negative margins and no extensive ductal carcinoma in situ) and in whom local therapy may have the largest impact on survival because of low systemic risk. Results: 965 patients were identified; 616 had BCT and 349 had MRM. The median follow-up time was 14.4 years (range, 8.4-23.3 years). Overall, 15-year rates of BCSS (76.0% vs 74.1%, P=.62), OS (74.2% vs 73.0%, P=.75), LRFS (85.4% vs 86.5%, P=.95), LRRFS (82.2% vs 81.6%, P=.61), and DRFS (74.4% vs 71.6%, P=.40) were similar between the BCT and MRM cohorts. In the “ideal” for BCT subgroup, there were 219 BCT and 67 MRM patients with a median follow-up time of 15.5 years. The 15-year BCSS (86.1% vs 82.9%, P=.57), OS (82.6% vs 82.9%, P=.89), LRFS (86.2% vs 84.2%, P=.50), LRRFS (83.1% vs 78.3%, P=.24), and DRFS (84.8% vs 79.1%, P=.17) were similar in the BCT and MRM cohorts. Conclusions: This population-based analysis with long-term follow-up confirmed that women younger than 40 years treated with BCT had similar 15-year outcomes compared with MRM. Young age alone is not a contraindication to BCT

  3. Absorber Materials for Transition-Edge Sensor X-ray Microcalorimeters

    Science.gov (United States)

    Brown, Ari-David; Bandler, Simon; Brekosky, Regis; Chervenak, James; Figueroa-Feliciano, Enectali; Finkbeiner, Fred; Sadleir, Jack; Iyomoto, Naoko; Kelley, Richard; Kilbourne, Caroline; hide

    2007-01-01

    Arrays of superconducting transition-edge sensors (TES) can provide high spatial and energy resolution necessary for x-ray astronomy. High quantum efficiency and uniformity of response can be achieved with a suitable absorber material, in which absorber x-ray stopping power, heat capacity, and thermal conductivity are relevant parameters. Here we compare these parameters for bismuth and gold. We have fabricated electroplated gold, electroplated gold/electroplated bismuth, and evaporated gold/evaporated bismuth 8x8 absorber arrays and find that a correlation exists between the residual resistance ratio (RRR) and thin film microstructure. This finding indicates that we can tailor absorber material conductivity via microstructure alteration, so as to permit absorber thermalization on timescales suitable for high energy resolution x-ray microcalorimetry. We show that by incorporating absorbers possessing large grain size, including electroplated gold and electroplated gold/electroplated bismuth, into our current Mo/Au TES, devices with tunable heat capacity and energy resolution of 2.3 eV (gold) and 2.1 eV (gold/bismuth) FWHM at 6 keV have been fabricated.

  4. A numerical evaluation of prediction accuracy of CO2 absorber model for various reaction rate coefficients

    Directory of Open Access Journals (Sweden)

    Shim S.M.

    2012-01-01

    Full Text Available The performance of the CO2 absorber column using mono-ethanolamine (MEA solution as chemical solvent are predicted by a One-Dimensional (1-D rate based model in the present study. 1-D Mass and heat balance equations of vapor and liquid phase are coupled with interfacial mass transfer model and vapor-liquid equilibrium model. The two-film theory is used to estimate the mass transfer between the vapor and liquid film. Chemical reactions in MEA-CO2-H2O system are considered to predict the equilibrium pressure of CO2 in the MEA solution. The mathematical and reaction kinetics models used in this work are calculated by using in-house code. The numerical results are validated in the comparison of simulation results with experimental and simulation data given in the literature. The performance of CO2 absorber column is evaluated by the 1-D rate based model using various reaction rate coefficients suggested by various researchers. When the rate of liquid to gas mass flow rate is about 8.3, 6.6, 4.5 and 3.1, the error of CO2 loading and the CO2 removal efficiency using the reaction rate coefficients of Aboudheir et al. is within about 4.9 % and 5.2 %, respectively. Therefore, the reaction rate coefficient suggested by Aboudheir et al. among the various reaction rate coefficients used in this study is appropriate to predict the performance of CO2 absorber column using MEA solution. [Acknowledgement. This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF, funded by the Ministry of Education, Science and Technology (2011-0017220].

  5. Evaluation of Cu2ZnSnS4 Absorber Films Sputtered from a Single, Quaternary Target

    OpenAIRE

    Carlhamn Rasmussen, Liv

    2013-01-01

    Cu2ZnSnS4 (CZTS) is a promising absorber material for thin-film solar cells since it contains no rare or toxic elements, has a high absorption coefficient and a near ideal bandgap energy. It does, however, present some challenges due to the limited single-phase region of the desired kesterite phase and its instability towards decomposition. Sputtering of CZTS from quaternary, compound targets using RF magnetron sputtering is known. In this thesis work CZTS absorbers were made using pulsed DC ...

  6. Radiation absorbed dose estimate for rubidium-82 determined from in vivo measurements in human subjects

    International Nuclear Information System (INIS)

    Ryan, J. W.; Harper, P.V.; Stark, V.S.; Peterson, E.L.; Lathrop, K.A.

    1986-01-01

    Radiation absorbed doses from rubidium-82 injected intravenously were determined in two young men, aged 23 and 27, using a dynamic conjugate counting technique to provide data for the net organ integrated time-activity curves in five organs: kidneys, lungs, liver, heart, and testes. This technique utilized a tungsten collimated Anger camera and the accuracy was validated in a prestwood phantom. The data for each organ were compared with conjugate count rates of a reference Ge-68/Ga-68 standard which had been calibrated against the Rb-82 injected. The effects of attenuation in the body were eliminated. The MIRD method was used to calculate the organ self absorbed doses and the total organ absorbed doses. The mean total absorbed doses were as follows (mrads/mCi injected): kidneys 30.9, heart walls 7.5, lungs 6.0, liver 3.0, testes 2.0 (one subject only), red marrow 1.3, remainder of body 1.3 and, extrapolating to women, ovaries 1.2. This absorbed dose to the kidney is significantly less than the pessimistic estimate of 59.4 mrads/mCi, made assuming instantaneous uptake and complete extraction of activity with no excretion by the kidneys, which receive 20% of the cardiac output. Further, in a 68 year old man the renal self absorbed dose was approximately 40% less than the mean renal self absorbed dose of the younger men. This decrease is probably related to the decline in renal blood flow which occurs with advancing age but other factors may also contribute to the observed difference. 14 references, 4 figures, 2 tables

  7. Efficient ASE management in disk laser amplifiers with variable absorbing clads

    Czech Academy of Sciences Publication Activity Database

    Slezák, Ondřej; Lucianetti, Antonio; Mocek, Tomáš

    2014-01-01

    Roč. 50, č. 12 (2014), s. 1052-1060 ISSN 0018-9197 R&D Projects: GA MŠk ED2.1.00/01.0027; GA MŠk EE2.3.20.0143 Grant - others:HILASE(XE) CZ.1.05/2.1.00/01.0027; OP VK 6(XE) CZ.1.07/2.3.00/20.0143 Institutional support: RVO:68378271 Keywords : amplifiers * laser * absorbing * Yb:YAG * multi slab Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.887, year: 2014

  8. Outcome of childhood anorexia nervosa-The results of a five- to ten-year follow-up study.

    Science.gov (United States)

    Herpertz-Dahlmann, Beate; Dempfle, Astrid; Egberts, Karin Maria; Kappel, Viola; Konrad, Kerstin; Vloet, Jennifer Anne; Bühren, Katharina

    2018-04-01

    Although admissions of children with anorexia nervosa (AN) are increasing, there remains a dearth of up-to-date knowledge of the course and outcome of early-onset AN. The aim of the present study was to investigate the outcomes of patients with AN onset before the age of 14. Sixty-eight consecutive former patients who met the DSM-IV criteria for AN and who had been treated at one of three German university hospitals were asked to participate in a follow-up study. Body mass index, body height, outcome of the eating disorder (ED), psychiatric morbidity, and health related quality of life (HRQoL) were assessed through a personal examination after an average time span of 7.5 years (range: 4.5-11.5 years) after admission. One patient had died. Fifty-two subjects with a mean age of 12.5 (SD 1.0) years at admission and of 20.2 (SD 2.0) years at follow-up agreed to participate in the follow-up assessment, aggregating to 77.9% of the original sample. Approximately 41% of the participants had a good outcome, while 35% and 24% had intermediate and poor outcomes, respectively. Twenty-eight percent of the sample met the DSM-IV criteria for a current non-ED psychiatric disorder, and 64% met the criteria for a past non-ED psychiatric disorder. Mental HRQoL and ED-specific psychopathology was strongly associated with the outcome of AN. Average body height was below the normal range. A higher weight at admission was the only significant positive indicator of outcome. Childhood AN is a serious disorder with an unfavorable course in many patients and high rates of chronicity and psychiatric comorbidity in young adulthood. Early detection and intervention are urgently needed. © 2018 Wiley Periodicals, Inc.

  9. Amine-Functionalized Amino Acid-based Ionic Liquids as Efficient and High-Capacity Absorbents for CO2

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kunov-Kruse, Andreas Jonas; Fehrmann, Rasmus

    2014-01-01

    Ionic liquids (ILs) comprised of ammonium cations and anions of naturally occurring amino acids containing an additional amine group (e.g., lysine, histidine, asparagine, and glutamine) were examined as high-capacity absorbents for CO2. An absorption capacity of 2.1 mol CO2 per mol of IL (3.5 mol...

  10. Outcome of Treatment of Uveitic Macular Edema: The Multicenter Uveitis Steroid Treatment Trial 2-Year Results.

    Science.gov (United States)

    Tomkins-Netzer, Oren; Lightman, Susan; Drye, Lea; Kempen, John; Holland, Gary N; Rao, Narsing A; Stawell, Richard J; Vitale, Albert; Jabs, Douglas A

    2015-11-01

    To evaluate the 2-year outcomes of uveitic macular edema. Longitudinal follow-up of a randomized cohort. At baseline, 148 eyes of 117 patients enrolled in the Multicenter Uveitis Steroid Treatment (MUST) Trial had macular edema, and 134 eyes of 108 patients completed 2-year follow-up. Patients enrolled in the study were randomized to either systemic immunosuppression or intravitreal fluocinolone acetonide implant therapy. Macular edema was defined as thickening of the retina (center point thickness≥240 μm) on time-domain optical coherence tomography (OCT) of macula. Improvement in macular edema (≥20% reduction in central point thickness on OCT), resolution of macular edema (normalization of thickness on OCT), and best-corrected visual acuity (BCVA). Between randomization and 2-years' follow-up, 62% and 25% of eyes in the systemic and implant groups, respectively, received at least 1 supplemental regional corticosteroid injection. By 2-years' follow-up, macular edema improved in 71% of eyes and resolved in 60%. There were no differences between treatment groups in the proportion of eyes with macular edema improving (systemic therapy vs. implant, 65% vs. 77%; P=0.20) and resolving (52% vs. 68%; P=0.28), but eyes randomized to implant had more improvement in macular thickness (median decrease of 180 vs. 109 μm in the systemic therapy group; P=0.04). Eyes with baseline fluorescein angiographic leakage were more likely to improve than those without (76% vs. 58%; P=0.03). Overall, there was a mean 5-letter (1 line) improvement in BCVA at 2 years. Mean changes in BCVA from baseline at 2 years by macular edema response status were: resolution, +10 letters; improvement without resolution, +10 letters (P=0.92); little to no change, 6 letters (P=0.19); and worsening, -16 letters (worsening acuity; P=0.0003). About two thirds of eyes with uveitic macular edema were observed to experience improvement in the edema and visual acuity with implant or systemic treatment

  11. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography: Insights From the ABSORB Cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions)

    NARCIS (Netherlands)

    Onuma, Y.; Grundeken, M.J.; Nakatani, S.; Asano, T.; Sotomi, Y.; Foin, N.; Ng, J.; Okamura, T.; Wykrzykowska, J.J.; Winter, R.J. de; Geuns, R.J.M. van; Koolen, J.; Christiansen, E.; Whitbourn, R.; McClean, D.; Smits, P; Windecker, S.; Ormiston, J.A.; Serruys, P.W.

    2017-01-01

    BACKGROUND: The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb

  12. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography Insights From the ABSORB Cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions)

    NARCIS (Netherlands)

    Onuma, Yoshinobu; Grundeken, Maik J.; Nakatani, Shimpei; Asano, Taku; Sotomi, Yohei; Foin, Nicolas; Ng, Jaryl; Okamura, Takayuki; Wykrzykowska, Joanna J.; de Winter, Robbert J.; van Geuns, Robert-Jan; Koolen, Jacques; Christiansen, Evald; Whitbourn, Robert; McClean, Dougal; Smits, Pieter; Windecker, Stephan; Ormiston, John A.; Serruys, Patrick W.

    2017-01-01

    Background-The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb

  13. Electromagnetic and microwave absorbing properties of hollow ...

    Indian Academy of Sciences (India)

    bandwidth below −10 dB and minimum RL decrease with increasing thickness of HCNSs/paraffin composites. Keywords. Nanomaterials; nanospheres; CVD; electric; magnetic; microwave absorption properties. 1. Introduction. In recent years, microwave absorbing materials have attracted considerable attention because it ...

  14. Two-Year Outcomes of a Population-Based Intervention for Preschool Language Delay: An RCT.

    Science.gov (United States)

    Wake, Melissa; Levickis, Penny; Tobin, Sherryn; Gold, Lisa; Ukoumunne, Obioha C; Goldfeld, Sharon; Zens, Naomi; Le, Ha N D; Law, James; Reilly, Sheena

    2015-10-01

    We have previously shown short-term benefits to phonology, letter knowledge, and possibly expressive language from systematically ascertaining language delay at age 4 years followed by the Language for Learning intervention. Here, we report the trial's definitive 6-year outcomes. Randomized trial nested in a population-based ascertainment. Children with language scores >1.25 SD below the mean at age 4 were randomized, with intervention children receiving 18 1-hour home-based therapy sessions. Primary outcome was receptive/expressive language. Secondary outcomes were phonological, receptive vocabulary, literacy, and narrative skills; parent-reported pragmatic language, behavior, and health-related quality of life; costs of intervention; and health service use. For intention-to-treat analyses, trial arms were compared using linear regression models. Of 1464 children assessed at age 4, 266 were eligible and 200 randomized; 90% and 82% of intervention and control children were retained respectively. By age 6, mean language scores had normalized, but there was little evidence of a treatment effect for receptive (adjusted mean difference 2.3; 95% confidence interval [CI] -1.2 to 5.7; P = .20) or expressive (0.8; 95% CI -1.6 to 3.2; P = .49) language. Of the secondary outcomes, only phonological awareness skills (effect size 0.36; 95% CI 0.08-0.65; P = .01) showed benefit. Costs were higher for intervention families (mean difference AU$4276; 95% CI: $3424 to $5128). Population-based intervention targeting 4-year-old language delay was feasible but did not have lasting impacts on language, possibly reflecting resolution in both groups. Long-term literacy benefits remain possible but must be weighed against its cost. Copyright © 2015 by the American Academy of Pediatrics.

  15. Black phosphorus saturable absorber for a diode-pumped passively Q-switched Er:CaF2 mid-infrared laser

    Science.gov (United States)

    Li, Chun; Liu, Jie; Guo, Zhinan; Zhang, Han; Ma, Weiwei; Wang, Jingya; Xu, Xiaodong; Su, Liangbi

    2018-01-01

    A multilayer black phosphorus, as a novel two dimensional saturable absorber, has superb saturable absorption properties for a Er:CaF2 solid-state pulse laser. The pulse laser is realized at mid-infrared region with the passively Q-switched technology by a diode-pumping. The high-quality black phosphorus saturable absorber is fabricated by liquid phase exfoliation method. The pulse laser generates the pulses operation with the pulse duration of 954.8 ns, the repetition rate of 41.93 kHz, the pulse energy of 4.25 μJ and the peak power of 4.45 W. Our work demonstrates that black phosphorus could be used as a kind of efficient mid-infrared region optical absorber for ultrafast photonics.

  16. Assessment of Absorbed Dose in Persons close to the Patients during 192Ir brachytherapy for Cervical Cancer

    International Nuclear Information System (INIS)

    Jung, Joo Young; Kang, Se Sik

    2010-01-01

    According to the 2007 Annual Report of the National Cancer Registry, cervical cancer showed an occurring frequency of 7th in female cancers and 4rd in females with an age of 35-64 years. Both radiotherapy and chemotherapy are mainly used for the treatment of cervical cancer. In case of radiotherapy, brachytherapy using radioisotopes in conjunction with external-beam radiation therapy (EBRT) using a linear accelerator is used in most cases to improve the outcome of cancer treatment. Brachytherapy, one of the cervical cancer radiotherapies, is a method that can minimize the damage of normal tissues restricting absorbed dose to uterus. It is, however, necessary to conduct a quantitative assessment on brachytherapy because it may cause radiation exposure to medical care providers during the radiotherapy. Therefore, the study provides the basic research data regarding brachytherapy for cervical cancer, estimating the absorbed dose in persons close to the patients using a mathematical phantom during 192Ir brachytherapy for cervical cancer

  17. The effect of Arctic sea-ice extent on the absorbed (net solar flux at the surface, based on ISCCP-D2 cloud data for 1983–2007

    Directory of Open Access Journals (Sweden)

    C. Matsoukas

    2010-01-01

    Full Text Available We estimate the effect of the Arctic sea ice on the absorbed (net solar flux using a radiative transfer model. Ice and cloud input data to the model come from satellite observations, processed by the International Satellite Cloud Climatology Project (ISCCP and span the period July 1983–June 2007. The sea-ice effect on the solar radiation fluctuates seasonally with the solar flux and decreases interannually in synchronisation with the decreasing sea-ice extent. A disappearance of the Arctic ice cap during the sunlit period of the year would radically reduce the local albedo and cause an annually averaged 19.7 W m2 increase in absorbed solar flux at the Arctic Ocean surface, or equivalently an annually averaged 0.55 W m2 increase on the planetary scale. In the clear-sky scenario these numbers increase to 34.9 and 0.97 W m2, respectively. A meltdown only in September, with all other months unaffected, increases the Arctic annually averaged solar absorption by 0.32 W m2. We examined the net solar flux trends for the Arctic Ocean and found that the areas absorbing the solar flux more rapidly are the North Chukchi and Kara Seas, Baffin and Hudson Bays, and Davis Strait. The sensitivity of the Arctic absorbed solar flux on sea-ice extent and cloud amount was assessed. Although sea ice and cloud affect jointly the solar flux, we found little evidence of strong non-linearities.

  18. Preoperative MRI findings predict two-year postoperative clinical outcome in lumbar spinal stenosis.

    Directory of Open Access Journals (Sweden)

    Pekka Kuittinen

    Full Text Available To study the predictive value of preoperative magnetic resonance imaging (MRI findings for the two-year postoperative clinical outcome in lumbar spinal stenosis (LSS.84 patients (mean age 63±11 years, male 43% with symptoms severe enough to indicate LSS surgery were included in this prospective observational single-center study. Preoperative MRI of the lumbar spine was performed with a 1.5-T unit. The imaging protocol conformed to the requirements of the American College of Radiology for the performance of MRI of the adult spine. Visual and quantitative assessment of MRI was performed by one experienced neuroradiologist. At the two-year postoperative follow-up, functional ability was assessed with the Oswestry Disability Index (ODI 0-100% and treadmill test (0-1000 m, pain symptoms with the overall Visual Analogue Scale (VAS 0-100 mm, and specific low back pain (LBP and specific leg pain (LP separately with a numeric rating scale from 0-10 (NRS-11. Satisfaction with the surgical outcome was also assessed.Preoperative severe central stenosis predicted postoperatively lower LP, LBP, and VAS when compared in patients with moderate central stenosis (p<0.05. Moreover, severe stenosis predicted higher postoperative satisfaction (p = 0.029. Preoperative scoliosis predicted an impaired outcome in the ODI (p = 0.031 and lowered the walking distance in the treadmill test (p = 0.001. The preoperative finding of only one stenotic level in visual assessment predicted less postoperative LBP when compared with patients having 2 or more stenotic levels (p = 0.026. No significant differences were detected between quantitative measurements and the patient outcome.Routine preoperative lumbar spine MRI can predict the patient outcome in a two-year follow up in patients with LSS surgery. Severe central stenosis and one-level central stenosis are predictors of good outcome. Preoperative finding of scoliosis may indicate worse functional ability.

  19. ABSORBENCY CHARACTERISTICS OF PESHTAMALS: TRADITIONAL TURKISH WOVEN CLOTHES

    Directory of Open Access Journals (Sweden)

    KESKIN Reyhan

    2014-05-01

    Full Text Available Absorbency of textiles is defined as the ability of taking in a fluid in the manner of a sponge. Absorbency is required for comfort properties in so me clothes such as sportswear and underwear clothing, for drying properties in napkins, towels and bathrobes, for health concerns in some medical textiles such as bandages, gauze and absorbent cotton, and for cleaning properties in washclothes and mops. In this study five different fabric samples (three woven 100% cotton fabrics A, B and P respectively at plain, twill, and peshtamal weaving patterns and two 100% cotton terry towels T1 and T2 were tested. The absorbency properties of the samples were evaluated according to the droplet test, sinking time test and wicking height tests (pottasium chromate test. Peshtamal samples showed better absorbency results than plain and twill weaves and lower but close results to towel samples according to the droplet test, sinking time test and wicking height tests. The absorbency properties of peshtamals showed results close to towel samples. The void content of peshtamals is higher than plain and twill samples but closer and lower than towel samples. The good absorbency results of peshtamals might be due to the void content of peshtamals which is higher than plain and twill samples but closer and lower than towel samples. Peshtamals which are good in absorbency and light in weight might be used widespreadly in daily life for their high absorbency, and on travel for weight saving purposes.

  20. Two-year survival and neurodevelopmental outcomes after cardiopulmonary resuscitation in neonatal patients after complex cardiac surgery.

    Science.gov (United States)

    Hansen, Gregory; Joffe, Ari R; Nettel-Aguirre, Alberto; Robertson, Charlene M T; Biggs, Wayne S G; Ross, David B; Rebeyka, Ivan M

    2011-03-01

    To examine survival and neurodevelopmental outcomes in neonates having post-operative cardiopulmonary resuscitation (CPR). This inception cohort study included all neonates (6 weeks old or less) who received postoperative CPR (Group 1) after cardiac surgery from 1996 to 2005, matched for heart defect, year of surgery, chromosomal abnormality, and socioeconomic status to two neonates who did not receive postoperative CPR (Group 2). Two-year neurodevelopment was prospectively assessed with Bayley Scales of Infant Development II and Adaptive Behavior Assessment System II. Pre-, intra-, and post-operative variables were collected prospectively. Cardiac arrest variables were collected retrospectively. Predictors of mortality were analyzed by univariate analysis and conditional multiple logistic regression. There were 29 patients in Group 1, and 58 patients in Group 2. In survivors, there were no significant differences between Groups 1 and 2 in outcomes [mean (SD)] of mental developmental index [84.5 (12.2) vs. 81.0 (18.9)], psychomotor developmental index [82.8 (13.8) vs. 80.1 (21.9)], General Adaptive Composite [84.6 (15.3) vs. 84.3 (19.2)], Motor scale [8.4 (3.2) vs. 8.0 (3.8)], or delay on any of these scales. Two-year mortality [58.6% Group 1; 8.6% Group 2], was associated on conditional multiple logistic regression with CPR (OR 26.6; 95% CI, 5.4, 129.5). In Group 1, on multiple logistic regression, 2-year mortality was associated with minutes of chest compressions (OR 1.04, 95% CI, 1.01, 1.08). Among neonates having cardiac surgery, CPR is associated with greater mortality. There is no evidence that CPR survivors have different 2-year neurodevelopmental outcomes than those neonates not having CPR. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Opto-electronic characterization of polycrystalline CuInS2 and Cu(In,Ga)S2 absorber layers by photoluminescence

    International Nuclear Information System (INIS)

    Heidemann, Florian

    2011-01-01

    Photoluminescence (PL) is an established method to characterize the optoelectronic properties of solar cell absorber layers. With the help of Planck's generalized law it is in principle possible to determine the quasi-Fermi level splitting - which is the upper limit of the open circuit voltage V oc - and the absorption coefficient of a solar cell before its actual completion. For large-scale measurements (mm/cm regime) this is valid for absorber layers with lateral homogeneous properties, however it is not directly transferable to polycrystalline semiconductors due to laterally fluctuating opto-electronic and structural parameters. The lateral fluctuations in opto-electronic properties of polycrystalline Cu(In 1-ξ Ga ξ )S 2 have been analyzed (e.g. with respect to fluctuations in quasi-Fermi level splitting, optical band-gap and sub band-gap absorbance) by measuring laterally and spectrally resolved PL on the μm-scale and providing the transition towards macroscopic PL measurements on the mm-scale. To give a comprehensive characterization, surface roughness and optical properties have been studied and methods for feature extraction have been applied. On the microscopic scale variations in the quasi-Fermi level splitting Δ x,y E Fnp of about 38 meV (CuInS 2 ) and 53 meV (Cu(In,Ga)S 2 ) have been found. From local absorbance spectra extracted from PL measurements on Cu(In,Ga)S 2 fluctuations in the optical band-gap E opt with a full width at half maximum of FWHM E opt ∼80 meV could be extracted, whereas band-gap fluctuations in CuInS 2 are found to be negligible. Thus band-gap fluctuations seem to be mainly caused by a varying gallium (Ga) content. Furthermore, regions with higher E opt and with it a potential higher Ga content, show a higher quasi-Fermi level splitting. As a major limiting factor for the local quasi-Fermi level splitting E Fnp the local density of deep defects could be identified. Due to low luminescence yields of Cu(In 1-ξ Ga ξ )S 2 under

  2. Inferring absorbing organic carbon content from AERONET data

    Science.gov (United States)

    Arola, A.; Schuster, G.; Myhre, G.; Kazadzis, S.; Dey, S.; Tripathi, S. N.

    2011-01-01

    Black carbon, light-absorbing organic carbon (often called "brown carbon") and mineral dust are the major light-absorbing aerosols. Currently the sources and formation of brown carbon aerosol in particular are not well understood. In this study we estimated the amount of light-absorbing organic carbon and black carbon from AERONET measurements. We find that the columnar absorbing organic carbon (brown carbon) levels in biomass burning regions of South America and Africa are relatively high (about 15-20 mg m-2 during biomass burning season), while the concentrations are significantly lower in urban areas in US and Europe. However, we estimated significant absorbing organic carbon amounts from the data of megacities of newly industrialized countries, particularly in India and China, showing also clear seasonality with peak values up to 30-35 mg m-2 during the coldest season, likely caused by the coal and biofuel burning used for heating. We also compared our retrievals with the modeled organic carbon by the global Oslo CTM for several sites. Model values are higher in biomass burning regions than AERONET-based retrievals, while the opposite is true in urban areas in India and China.

  3. Tuberculosis treatment outcome and predictors in northern Ethiopian prisons: a five-year retrospective analysis.

    Science.gov (United States)

    Adane, Kelemework; Spigt, Mark; Dinant, Geert-Jan

    2018-02-20

    The prison situations are notorious for causing interruptions of tuberculosis (TB) treatment and occurrence of unfavorable outcomes. In Ethiopian prisons, though TB treatment programs exist, treatment outcome results and factors contributing to unsuccessful outcome are not well documented. In this study, we assessed the treatment outcome of TB cases and identified risk factors for unsuccessful outcome in northern Ethiopian prisons. A retrospective record review was conducted for all prisoners diagnosed with TB between September 2011 and August 2015. Outcome variables were defined following WHO guidelines. Out of the 496 patients, 11.5% were cured, 68% completed treatment, 2.5% were lost to follow-up, 1.6% were with a treatment failure, 1.4% died, and 15% were transferred out. All transferred out or released prisoners were not appropriately linked to health facilities and might be lost to treatment follow-up. The overall treatment success rate (TSR) of the 5 years was 94% among the patients who were not transferred out. The odds of unsuccessful outcome were 4.68 times greater among re-treatment cases compared to the newly treated cases. The year of treatment was also associated with variations in TSR; those treated during the earlier year were more likely to have unsuccessful outcome. Sputum non-conversion at the second-month check-up was strongly associated with unsuccessful outcome among the smear-positive cases. The mean TSR of the prisoners in the study prisons was quite satisfactory when gauged against the target level set by the End TB Strategy. However, the lack of appropriate linkage and tracking systems for those prisoners transferred or released before their treatment completion would have a negative implication for the national TB control program as such patients might interrupt their treatment and develop drug-resistant TB. Being in a re-treatment regimen and sputum non-conversion at the second-month check-up were significantly associated with

  4. Neurobehavioral Outcomes 11 Years After Neonatal Caffeine Therapy for Apnea of Prematurity.

    Science.gov (United States)

    Mürner-Lavanchy, Ines M; Doyle, Lex W; Schmidt, Barbara; Roberts, Robin S; Asztalos, Elizabeth V; Costantini, Lorrie; Davis, Peter G; Dewey, Deborah; D'Ilario, Judy; Grunau, Ruth E; Moddemann, Diane; Nelson, Harvey; Ohlsson, Arne; Solimano, Alfonso; Tin, Win; Anderson, Peter J

    2018-05-01

    Caffeine is effective in the treatment of apnea of prematurity. Although caffeine therapy has a benefit on gross motor skills in school-aged children, effects on neurobehavioral outcomes are not fully understood. We aimed to investigate effects of neonatal caffeine therapy in very low birth weight (500-1250 g) infants on neurobehavioral outcomes in 11-year-old participants of the Caffeine for Apnea of Prematurity trial. Thirteen academic hospitals in Canada, Australia, Great Britain, and Sweden participated in this part of the 11-year follow-up of the double-blind, randomized, placebo-controlled trial. Measures of general intelligence, attention, executive function, visuomotor integration and perception, and behavior were obtained in up to 870 children. The effects of caffeine therapy were assessed by using regression models. Neurobehavioral outcomes were generally similar for both the caffeine and placebo group. The caffeine group performed better than the placebo group in fine motor coordination (mean difference [MD] = 2.9; 95% confidence interval [CI]: 0.7 to 5.1; P = .01), visuomotor integration (MD = 1.8; 95% CI: 0.0 to 3.7; P prematurity improved visuomotor, visuoperceptual, and visuospatial abilities at age 11 years. General intelligence, attention, and behavior were not adversely affected by caffeine, which highlights the long-term safety of caffeine therapy for apnea of prematurity in very low birth weight neonates. Copyright © 2018 by the American Academy of Pediatrics.

  5. Ten year experience with antiretroviral treatment in Cambodia: Trends in patient characteristics and treatment outcomes.

    Directory of Open Access Journals (Sweden)

    Phirum Lay

    Full Text Available Although HIV disease stage at ART initiation critically determines ART outcomes, few reports have longitudinally monitored this within Asia. Using prospectively collected data from a large ART program at Sihanouk Hospital Center of Hope in Cambodia, we report on the change in patient characteristics and outcomes over a ten-year period.We conducted a retrospective analysis including all adults (≥ 18 years old starting ART from March 2003-March 2013 in a non-governmental hospital in Phnom Penh, Cambodia. The cumulative incidence of death, lost to follow-up (LTFU, attrition (death or LTFU and first line treatment failure were calculated using Kaplan-Meier methods. Independent risk factors for these outcomes were determined using Cox regression modeling.Over the ten-year period, 3581 patients initiated ART with a median follow-up time of 4.8 years (IQR 2.8-7.2. The median age was 35 years (IQR 30-41, 54% were female. The median CD4 count at ART initiation increased from 22 cells/μL (IQR 4-129 in 2003 to 218 (IQR 57-302 in 2013. Over the 10 year period, a total of 282 (7.9% individuals died and 433 (12.1% were defined LTFU. Program attrition (died or LTFU was 11.1% (95% CI: 10.1%- 12.4% at one year, 16.3% (95% CI: 15.1%-17.6% at three years, 19.8% (95% CI: 18.5%-21.2% at five years and 23.3% (95% CI: 21.6-25.1 at ten years. Male sex and low baseline body mass index (BMI were associated with increased attrition. Factors independently associated with mortality included a low baseline CD4 count, older age, male sex, low baseline BMI and hepatitis B co-infection. Individuals aged above 40 years old had an increased risk of mortality but were less likely to LTFU. There were a total of 137 individuals with first line ART failure starting second line treatment. The probability of first line failure was estimated at 2.8% (95% CI: 2.3%-3.4% at 3 years, 4.6% (95% CI: 3.9%-5.5% at 5 years and 7.8% (95% CI 4.8%-12.5% at ten years of ART. The probability was

  6. One-year postpartum outcomes following a weight management intervention in pregnant women with obesity

    Science.gov (United States)

    Vesco, Kimberly K.; Leo, Michael C.; Karanja, Njeri; Gillman, Matthew W.; McEvoy, Cindy T.; King, Janet C.; Eckhardt, Cara L.; Smith, K. Sabina; Perrin, Nancy; Stevens, Victor J.

    2016-01-01

    Objective This analysis focuses on 1-year maternal and infant follow-up of a randomized trial that tested a weight management intervention conducted during pregnancy. Methods We randomly assigned 114 women with obesity (mean BMI 36.7 kg/m2) at a mean of 15 weeks’ gestation to a weight management intervention or usual care control condition. The intervention ended at delivery and resulted in less gestational weight gain and a lower proportion of large-for-gestational age newborns among intervention compared to control participants. The primary outcome at 12 months postpartum was maternal weight. Secondary outcomes included infant weight-for-age and weight-for-length z-scores. Results At 1 year, mothers in the intervention group weighed 96.3±18.6 kg, and in the control group, 99.7±19.2 kg. There was no significant difference between groups in change in weight from randomization to 1-year postpartum (b=-0.47, 95% CI [-4.03, 3.08]. There was a significant main effect of group for infant weight-for-age z-score (b=-0.40, 95% CI [-0.75,-0.05]) but not infant weight-for-length z-scores (b=-0.20, 95% CI [-0.59,0.20]. Conclusions A gestational weight management intervention did not influence maternal weight or infant weight-for-length at 1-year postpartum. Future studies may be warranted to determine if extending prenatal interventions into the postpartum period would be beneficial for maternal and infant outcomes. PMID:27670399

  7. Fabrication of selective solar absorbers using pulsed laser deposition

    CSIR Research Space (South Africa)

    Yalisi, B

    2009-06-01

    Full Text Available Selective solar absorbers are devices that have been designed to absorb as much as possible of the solar radiation which is in the wavelength range of 0.3 to 2.5 µm and to minimise thermal emittance in the wavelength range from 2.5µm to the far...

  8. Hydraulic shock absorbers

    International Nuclear Information System (INIS)

    Thatcher, G.; Davidson, D. F.

    1984-01-01

    A hydraulic shock absorber of the dash pot kind for use with electrically conducting liquid such as sodium, has magnet means for electro magnetically braking a stream of liquid discharged from the cylinder. The shock absorber finds use in a liquid metal cooled nuclear reactor for arresting control rods

  9. Double-bundle PCL reconstruction using autologous hamstring tendons: outcome with a minimum 2-year follow-up

    Directory of Open Access Journals (Sweden)

    Ricardo de Paula Leite Cury

    Full Text Available ABSTRACT OBJECTIVE: To present the outcomes of posterior cruciate ligament (PCL double-bundle reconstruction using autologous hamstring tendons, with a minimum follow-up of two years. METHODS: Evaluation of 16 cases of PCL injury that underwent double-bundle reconstruction with autogenous hamstring tendons, between 2011 and 2013. The final sample consisted of 16 patients, 15 men and one woman, with a mean age of 31 years (21-49. The predominant mechanism was motorcycle accident in half of the cases. There was a mean interval of 15 months between the time of lesion and the surgery (three to 52 months. Five lesions were isolated and 11, associated. Clinical evaluation, application of validated scores, and measurements with use of the KT-1000 were performed. RESULTS: The analysis showed a mean preoperative Lysholm score of 50 points (28-87, progressing to 94 points (85-100 postoperatively. The IKDC score also demonstrated improvement. In the preoperative evaluation, four and 12 patients were respectively classified as C (abnormal and D (very unusual, and in the postoperative evaluation six as A (normal and ten as B (close to normal. In the post-operative evaluation by KT1000 arthrometer, 13 patients showed difference between 0-2 mm and 3 between 3 and 5 mm, when compared with the contralateral side. CONCLUSION: Autologous hamstring tendons are a viable option in double-bundle reconstruction of the PCL, with good clinical results in a minimum follow-up of two years.

  10. Phase 2 report on the evaluation of polyacrylonitrile (PAN) as a binding polymer for absorbers used to treat liquid radioactive wastes

    International Nuclear Information System (INIS)

    Sebesta, F.; John, J.; Motl, A.

    1996-05-01

    The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO 3 + 1 M NaNO 3 + 2 x 10 -5 M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO 3 + x x 10 -4 M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10 3 could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN absorber, the decontamination factor of about 10 3 could be maintained for a feed volume as great as 1,800 BV. In alkaline simulant solutions, significant decomposition of the active components was observed, and the best performance was exhibited by the KCoFC-PAN absorber. Introductory experiments confirmed that Cs may be washed out of the composite absorbers. Regeneration of both absorbers for repetitive use was also found to be possible. The main result of the study is that PAN was proven to be a versatile polymer capable of forming porous composite absorbers with a large number of primary absorbers. The composite absorbers proved to be capable of withstanding the harsh acidic and alkaline conditions and significant radiation doses that may be expected in the treatment of US DOE wastes. A field demonstration is proposed as a follow-on activity

  11. Corrosion resistant neutron absorbing coatings

    Science.gov (United States)

    Choi, Jor-Shan [El Cerrito, CA; Farmer, Joseph C [Tracy, CA; Lee, Chuck K [Hayward, CA; Walker, Jeffrey [Gaithersburg, MD; Russell, Paige [Las Vegas, NV; Kirkwood, Jon [Saint Leonard, MD; Yang, Nancy [Lafayette, CA; Champagne, Victor [Oxford, PA

    2012-05-29

    A method of forming a corrosion resistant neutron absorbing coating comprising the steps of spray or deposition or sputtering or welding processing to form a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material. Also a corrosion resistant neutron absorbing coating comprising a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material.

  12. Vapor diffusion synthesis of rugby-shaped CoFe2O4/graphene composites as absorbing materials

    International Nuclear Information System (INIS)

    Zhang, Shenli; Jiao, Qingze; Hu, Ju; Li, Jingjing; Zhao, Yun; Li, Hansheng; Wu, Qin

    2015-01-01

    Graphical abstract: CoFe 2 O 4 rugbies/graphene composites were prepared using a vapor diffusion method followed by calcination. As-synthesized rugby-like CoFe 2 O 4 particles were distributed on the graphene sheet. PVP played a key role for the formation of rugby-shaped morphology of CoFe 2 O 4 particles. A minimum reflection loss of −39.0 dB was observed at 10.9 GHz for the CoFe 2 O 4 rugbies/graphene composites with a thickness of 2 mm, and the effective absorption bandwidth was 4.7 GHz. The CoFe 2 O 4 rugbies/graphene composites exhibited better microwave absorbing performance than that of the CoFe 2 O 4 nanoparticles/graphene composites prepared without PVP. - Highlights: • CoFe 2 O 4 rugbies/graphene hybrids were synthesized using a vapor diffusion method. • PVP played a key role for the formation of CoFe 2 O 4 rugbies. • CoFe 2 O 4 rugbies/graphene composites showed excellent microwave absorbing property. - Abstract: Rugby-shaped CoFe 2 O 4 /graphene composites were synthesized using a vapor diffusion method in combination with calcination. The morphologies and structures of the products were characterized by field emission scanning electron microscopy, X-ray diffractometer, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. The magnetic and electromagnetic parameters were measured using a vibrating sample magnetometer and a vector network analyzer, respectively. Results show that rugby-shaped CoFe 2 O 4 particles are distributed on graphene sheets. A minimum reflection loss (RL) of −39.0 dB is observed at 10.9 GHz for the sample with a thickness of 2.0 mm, and the effective absorption frequency (RL < −10 dB) ranges from 9.6 to 14.3 GHz, indicating the excellent microwave absorption performance of the products. The absorbing performance of the CoFe 2 O 4 rugbies/graphene composites is better than that of the CoFe 2 O 4 nanoparticles/graphene composites

  13. PWR burnable absorber evaluation

    International Nuclear Information System (INIS)

    Cacciapouti, R.J.; Weader, R.J.; Malone, J.P.

    1995-01-01

    The purpose of the study was to evaluate the relative neurotic efficiency and fuel cycle cost benefits of PWR burnable absorbers. Establishment of reference low-leakage equilibrium in-core fuel management plans for 12-, 18- and 24-month cycles. Review of the fuel management impact of the integral fuel burnable absorber (IFBA), erbium and gadolinium. Calculation of the U 3 O 8 , UF 6 , SWU, fuel fabrication, and burnable absorber requirements for the defined fuel management plans. Estimation of fuel cycle costs of each fuel management plan at spot market and long-term market fuel prices. Estimation of the comparative savings of the different burnable absorbers in dollar equivalent per kgU of fabricated fuel. (author)

  14. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  15. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping; Wu, Ying; Lai, Yun

    2016-01-01

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  16. Antisocial Behavioral Syndromes and Three-Year Quality of Life Outcomes in United States Adults

    Science.gov (United States)

    Goldstein, Risë B.; Dawson, Deborah A.; Smith, Sharon M.; Grant, Bridget F.

    2013-01-01

    Objective To examine 3-year quality-of-life (QOL) outcomes among United States adults with Diagnostic and Statistical Manual of Mental Disorders – Fourth Edition (DSM-IV) antisocial personality disorder (ASPD), syndromal adult antisocial behavior without conduct disorder (CD) before age 15 (AABS, not a DSM-IV diagnosis), or no antisocial behavioral syndrome at baseline. Method Face-to-face interviews (n= 34,653). Psychiatric disorders were assessed using the Alcohol Use Disorder and Associated Disabilities Interview Schedule – DSM-IV Version. Health-related QOL was assessed using the Short-Form 12-Item Health Survey, version 2 (SF-12v2). Other outcomes included past-year Perceived Stress Scale-4 (PSS-4) scores, employment, receipt of Supplemental Security Income (SSI), welfare, and food stamps, and participation in social relationships. Results ASPD and AABS predicted poorer employment, financial dependency, social relationship, and physical health outcomes. Relationships of antisociality to SSI and food stamp receipt and physical health scales were modified by baseline age. Both antisocial syndromes predicted higher PSS-4, AABS predicted lower SF-12v2 Vitality, and ASPD predicted lower SF-12v2 Social Functioning scores in women. Conclusion Similar prediction of QOL by ASPD and AABS suggests limited utility of requiring CD before age 15 to diagnose ASPD. Findings underscore the need to improve prevention and treatment of antisocial syndromes. PMID:22375904

  17. Feynman Integrals with Absorbing Boundaries

    OpenAIRE

    Marchewka, A.; Schuss, Z.

    1997-01-01

    We propose a formulation of an absorbing boundary for a quantum particle. The formulation is based on a Feynman-type integral over trajectories that are confined to the non-absorbing region. Trajectories that reach the absorbing wall are discounted from the population of the surviving trajectories with a certain weighting factor. Under the assumption that absorbed trajectories do not interfere with the surviving trajectories, we obtain a time dependent absorption law. Two examples are worked ...

  18. Functional and motor outcome 5 years after stroke is equivalent to outcome at 2 months: follow-up of the collaborative evaluation of rehabilitation in stroke across Europe.

    Science.gov (United States)

    Meyer, Sarah; Verheyden, Geert; Brinkmann, Nadine; Dejaeger, Eddy; De Weerdt, Willy; Feys, Hilde; Gantenbein, Andreas R; Jenni, Walter; Laenen, Annouschka; Lincoln, Nadina; Putman, Koen; Schuback, Birgit; Schupp, Wilfried; Thijs, Vincent; De Wit, Liesbet

    2015-06-01

    Recovery of patients within the first 6 months after stroke is well documented, but there has been little research on long-term recovery. The aim of this study was to analyze functional and motor recovery between admission to rehabilitation centres and 5 years after stroke. This follow-up of the Collaborative Evaluation of Rehabilitation in Stroke Across Europe study, included patients from 4 European rehabilitation centres. Patients were assessed on admission, at 2 and 6 months, and 5 years after stroke, using the Barthel Index, Rivermead Motor Assessment Gross Function, Leg and Trunk function, and Arm function. Linear mixed models were used, corrected for baseline characteristics. To account for the drop-out during follow-up, the analysis is likelihood-based (assumption of missingness at random). A total of 532 patients were included in this study, of which 238 were followed up at 5 years post stroke. Mean age at stroke onset was 69 (±10 SD) years, 53% were men, 84% had ischemic strokes, and 53% had left-sided motor impairment. Linear mixed model analysis revealed a significant deterioration for all 4 outcomes between 6 months and 5 years (Pstroke. Higher age (Pstroke severity on admission (Pstroke severity negatively affected recovery up to 5 years after stroke. © 2015 American Heart Association, Inc.

  19. Outcomes at 7 years for babies who developed neonatal necrotising enterocolitis: the ORACLE Children Study.

    Science.gov (United States)

    Pike, Katie; Brocklehurst, Peter; Jones, David; Kenyon, Sarah; Salt, Alison; Taylor, David; Marlow, Neil

    2012-09-01

    Within the ORACLE Children Study Cohort, the authors have evaluated long-term consequences of the diagnosis of confirmed or suspected neonatal necrotising enterocolitis (NEC) at age of 7 years. Outcomes were assessed using a parental questionnaire, including the Health Utilities Index (HUI-3) to assess functional impairment, and specific medical and behavioural outcomes. Educational outcomes for children in England were explored using national standardised tests. Multiple logistic regression was used to explore independent associates of NEC within the cohort. The authors obtained data for 119 (77%) of 157 children following proven or suspected NEC and compared their outcomes with those of the remaining 6496 children. NEC was associated with an increase in risk of neonatal death (OR 14.6 (95% CI 10.4 to 20.6)). At 7 years, NEC conferred an increased risk of all grades of impairment. Adjusting for confounders, risks persisted for any HUI-3 defined functional impairment (adjusted OR 1.55 (1.05, 2.29)), particularly mild impairment (adjusted OR 1.61 (1.03, 2.53)) both in all NEC children and in those with proven NEC, which appeared to be independent. No behavioural or educational associations were confirmed. Following NEC, children were more likely to suffer bowel problems than non-NEC children (adjusted OR 3.96 (2.06, 7.61)). The ORACLE Children Study provided opportunity for the largest evaluation of school age outcome following neonatal NEC and demonstrates significant long-term consequences of both gut function (presence of stoma, admission for bowel problems and continuing medical care for gut-related problems) and motor, sensory and cognitive outcomes as measured using HUI-3.

  20. Outcome from 5-year live surgical demonstrations in urinary stone treatment: are outcomes compromised?

    NARCIS (Netherlands)

    Legemate, Jaap D.; Zanetti, Stefano P.; Baard, Joyce; Kamphuis, Guido M.; Montanari, Emanuele; Traxer, Olivier; de la Rosette, Jean Jmch

    2017-01-01

    To compare intra- and post-operative outcomes of endourological live surgical demonstrations (LSDs) and routine surgical practice (RSP) for urinary stones. Consecutive ureterorenoscopic (URS) and percutaneous (PNL) urinary stone procedures over a 5-year period were reviewed. Procedures were divided

  1. Predictive modelling of 2-year potency outcomes using a novel 90-day erection fullness scale after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Huynh, Linda M; Osann, Kathryn; Skarecky, Douglas; Ahlering, Thomas E

    2018-03-09

    To introduce a patient-reported erection fullness scale (%fullness) after robot-assisted radical prostatectomy (RARP) as a qualitative adjunct to the five-item version of the International Index of Erectile Function (IIEF-5) and as a 90-day predictor of 2-year potency outcomes. Prospective data were collected from 540 men with preoperative IIEF-5 scores of 22-25 who underwent RARP by a single surgeon, and of whom 299 had complete data at all time points up to 2 years. In addition to standard assessment tools (IIEF-5 and erections sufficient for intercourse [ESI]), the men were asked to 'indicate the fullness you are able to achieve in erections compared to before surgery?' (range: 0-100%). The primary outcome was prediction of potency (defined as ESI) at 24 months, based on 90-day %fullness tertile (0-24%, 25-74% and 75-100%). A total of 299 men with complete follow-up were included in the study. Significant predictors of 24-month potency included age, body mass index, pathological stage, nerve-sparing status and %fullness tertiles. When the men (preoperative IIEF-5 score 22-25) were assessed at 90 days after RARP, 181/299 (61%) had erections inadequate for intercourse. If IIEF-5 scores of 1-6 were used, 142/181 men (78%) would be targeted for early intervention. By contrast, if 0-24% fullness was used, 88/181 men (49%) would be targeted. If both the IIEF-5 score and %fullness were used, this would be reduced to 77/181 men (43%). We introduce %fullness as a qualitative adjunct to the IIEF-5 score, and separately as a 90-day predictor of 2-year potency recovery. This initial report is hypothesis-generating, such that the use of %fullness enables the identification of men who are most likely to benefit from early, secondary intervention. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  2. ABSORBABLE IRON IN BREAD: PROCEDURES OF ITS AUGMENTATION

    Directory of Open Access Journals (Sweden)

    M SABZEVARY

    2001-12-01

    Full Text Available Introduction: As many as 35 percent of the world population suffer from some degree of iron deficiency anemia. According to recent reports published by WHO and ICN (International Congress of Nutrition 20-40 percent of women are suffering from iron deficiency. Iron deficiency anemia is caused by lack of intake of the necessary doses of Fe+2 called Heme. The recommended intake dose is 10-17 mg Fe + 2/day. In Iran, bread is the main source of daily iron intake. However, the iron content of bread is Fe+3 which is not absorbable. The objectives of this study is to determine the levels of absorbable iron (Fe + 2 in two common types of Iranian bread and identify the means of raising these to an adequate levels.
    Methods: Random sampling method together with the normal distribution curve was employed in testing 120 samples of flour and bread. Quantification was carried out on each sample in duplicate using spectrophotometer at 510 mu, micrometer wave length. The effect of three organic acids (lactic ascorbic and acetic acid converting of Fe+3 to Fe + 2 was investigated. Two groups of bread was tested. One group was baked in tratitional oven (Noon-e-Tanoori and the second group through the common Iranian hot rotating iron plate baking machine (Noon-e-Machini.
    Results: Our results showed that the amount of absorbable Fe+2 in breads baked in rotatory oven (Noon-e-Tanoori is 0.8 ± 0.32 mg and the amount of unabsorbable Fe+3 in dried bread is 2.34 ± 0.25 mg/100 gm while the amount of absorbable Fe + 2 baked in traditional ovens is only 0.3±0.11 mg versus of unabsorbable Fe  + 3 1.9±0.13 mg/100 gm of dried bread. Meanwhile it was found that lactic and ascorbic acids can convert Fe+3 to Fe+2. Therefore, addition of one of these two acids to bread can catalyze conversion of unabsorbable Fe+3 to absorbable Fe + 2.
    Discussion: On the average an Iranian consumes 370 gm of

  3. Use of a novel fractional CO2 laser for the treatment of genitourinary syndrome of menopause: 1-year outcomes.

    Science.gov (United States)

    Sokol, Eric R; Karram, Mickey M

    2017-07-01

    To assess safety and efficacy of a fractional CO2 laser therapy for the treatment of genitourinary syndrome of menopause (GSM) with follow-up to 1 year posttreatment. Women presenting with GSM and meeting inclusion criterion were enrolled. Visual Analog Scales were used to grade vaginal pain, burning, itching, dryness, dyspareunia, and dysuria. Dilators were used to rate vaginal elasticity at baseline and at each follow-up visit. Before each treatment and at follow-up, Vaginal Health Index scoring and Female Sexual Function Index questionnaires were completed. Women received three vaginal laser treatments spaced 6 weeks apart. Participant satisfaction was measured on 5-point Likert scales (1 = very dissatisfied, 5 = very satisfied). Of 30 women (mean age 58.6 ± 8.8 years), three were lost to follow-up at 3 months and six at 1 year. None were discontinued or withdrew due to an adverse event. Average improvement in Visual Analog Scale scores for all symptom categories was statistically significant at 3 months and remained so through 1 year, except dysuria. Differences between data at 3 months and 1 year were not statistically significant, indicating persistence of positive outcomes. Average overall improvement in pain was 1.9 (±3.4), burning 1.9 (±3.1), itching 1.4 (±1.9), dryness 5.9 (±2.8), dyspareunia 4.9 (±3.3), and dysuria 0.9 (±3.1). Improvement in average Vaginal Health Index and Female Sexual Function Index scores was also statistically significant (P < 0.0001). Of 19 women undergoing dilator examination at 1 year, 18 (94.8%) were comfortable with the same or larger dilator size. Twenty-two of 24 women (92%) were satisfied or extremely satisfied with the treatment at 1 year. Based on study data up to 1 year, the fractional CO2 laser may be an effective and safe treatment for women suffering from symptoms of GSM, although additional studies with larger populations and placebo control is needed to confirm these results.

  4. Inferring absorbing organic carbon content from AERONET data

    Directory of Open Access Journals (Sweden)

    A. Arola

    2011-01-01

    Full Text Available Black carbon, light-absorbing organic carbon (often called "brown carbon" and mineral dust are the major light-absorbing aerosols. Currently the sources and formation of brown carbon aerosol in particular are not well understood. In this study we estimated the amount of light–absorbing organic carbon and black carbon from AERONET measurements. We find that the columnar absorbing organic carbon (brown carbon levels in biomass burning regions of South America and Africa are relatively high (about 15–20 mg m2 during biomass burning season, while the concentrations are significantly lower in urban areas in US and Europe. However, we estimated significant absorbing organic carbon amounts from the data of megacities of newly industrialized countries, particularly in India and China, showing also clear seasonality with peak values up to 30–35 mg m2 during the coldest season, likely caused by the coal and biofuel burning used for heating. We also compared our retrievals with the modeled organic carbon by the global Oslo CTM for several sites. Model values are higher in biomass burning regions than AERONET-based retrievals, while the opposite is true in urban areas in India and China.

  5. Reporting outcome measures of functional constipation in children from 0 to 4 years of age.

    Science.gov (United States)

    Kuizenga-Wessel, Sophie; Benninga, Marc A; Tabbers, Merit M

    2015-04-01

    Functional constipation (FC) often begins in the first year of life. Although standard definitions and criteria have been formulated to describe FC, these are rarely used in research and clinical practice. The aim of the study is to systematically assess how definitions and outcome measures are defined in therapeutic randomized controlled trials (RCTs) of infants with FC. PubMed, EMBASE, and Cochrane databases were searched. Studies were included if it was a (systematic review of) therapeutic RCT, children ≤4 years old, they had FC, a clear definition of constipation was provided, and were written in English. Quality was assessed using the Delphi list. A total of 1115 articles were found; only 5 studies fulfilled the inclusion criteria. Four different definitions were used, of which only 2 used the internationally accepted Rome III criteria. Defecation frequency was used as primary outcome in all included trials and stool consistency in 3 trials. Two trials involving infants investigated new infant formulas, whereas the third RCT evaluated the efficacy of a probiotic strain. The 2 trials including infants up to 4 years of age compared polyethylene glycol without electrolytes (PEG4000) with lactulose and milk of magnesia. All of the trials used nonvalidated parental diaries. Different definitions and outcome measures for FC in infants are used in RCTs. Disappointingly, there is a lack of well-designed therapeutic trials in infants with constipation. To make comparison between future trials possible, standard definitions, core outcomes, and validated instruments are needed.

  6. Visible light broadband perfect absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Jia, X. L.; Meng, Q. X.; Yuan, C. X.; Zhou, Z. X.; Wang, X. O., E-mail: wxo@hit.edu.cn [School of Science, Harbin Institute of Technology, Harbin 150001 (China)

    2016-03-15

    The visible light broadband perfect absorbers based on the silver (Ag) nano elliptical disks and holes array are studied using finite difference time domain simulations. The semiconducting indium silicon dioxide thin film is introduced as the space layer in this sandwiched structure. Utilizing the asymmetrical geometry of the structures, polarization sensitivity for transverse electric wave (TE)/transverse magnetic wave (TM) and left circular polarization wave (LCP)/right circular polarization wave (RCP) of the broadband absorption are gained. The absorbers with Ag nano disks and holes array show several peaks absorbance of 100% by numerical simulation. These simple and flexible perfect absorbers are particularly desirable for various potential applications including the solar energy absorber.

  7. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  8. Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Tabei, F.; Neshandar Asli, I.; Aghamiri, S.M.; Arbabi, K.

    2004-01-01

    Background: annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a physical parameter for quantification of ALARA law in nuclear medicine department. Materials and methods: as a part of nationwide study, this paper reports the staff and patient absorbed dose equivalents from diagnostic nuclear medicine examinations performed in four nuclear medicine department during 1999-2002. The type and frequency of examinations in each department were determined directly from hospital medical reports. Staff absorbed doses equivalents were calculated from regular personal dosimeter reports. Results: the total number of examinations increased by 16.7 % during these years. Annual patient collective dose equivalent increased about 13.0 % and the mean effective dose equivalent per exam was 3.61 ± 0.07 mSv. Annual total staff absorbed dose equivalent (total of 24 radiation workers) in four departments increased from 40.45 mSv to 47.81 mSv during four years that indicates an increase of about 20.6 %. The average of annual ratios of staff to patient effective dose equivalents in four departments were 1.83 x 10 -3 , 1.04 x 10 -3 , 3.28 x 10 -3 and 3.24 x 10 -3 , respectively, within a range of 0.9 x 10 -3 - 4.17 x 10 -3 . The mean value of ratios in four years was about 2.24 x 10 -3 ± 1.09 x 10 -3 that indicates the staff dose of about two 1000 th of patient dose. Conclusion: The mean value of ratios in four years was about 1.89 x 10 -3 ± 0.95 x 10 -3 indicating the staff dose of about one 1000 th of the patient dose. The staff to patient absorbed dose equivalent ratio could be used as a quantitative parameter for describing ALARA law in radiation protection and

  9. The association of maternal vitamin D status with infant birth outcomes, postnatal growth and adiposity in the first 2 years of life in a multi-ethnic Asian population: the Growing Up in Singapore Towards healthy Outcomes (GUSTO) cohort study.

    Science.gov (United States)

    Ong, Yi Lin; Quah, Phaik Ling; Tint, Mya Thway; Aris, Izzuddin M; Chen, Ling Wei; van Dam, Rob M; Heppe, Denise; Saw, Seang-Mei; Godfrey, Keith M; Gluckman, Peter D; Chong, Yap Seng; Yap, Fabian; Lee, Yung Seng; Foong-Fong Chong, Mary

    2016-08-01

    Maternal vitamin D status during pregnancy has been associated with infant birth and postnatal growth outcomes, but reported findings have been inconsistent, especially in relation to postnatal growth and adiposity outcomes. In a mother-offspring cohort in Singapore, maternal plasma vitamin D was measured between 26 and 28 weeks of gestation, and anthropometric measurements were obtained from singleton offspring during the first 2 years of life with 3-month follow-up intervals to examine birth, growth and adiposity outcomes. Associations were analysed using multivariable linear regression. Of a total of 910 mothers, 13·2 % were vitamin D deficient (growth outcomes - weight-for-age z-scores, length-for-age z-scores, circumferences of the head, abdomen and mid-arm at birth or postnatally - and adiposity outcomes - BMI, and skinfold thickness (triceps, biceps and subscapular) at birth or postnatally. Maternal vitamin D status in pregnancy did not influence infant birth outcomes, postnatal growth and adiposity outcomes in this cohort, perhaps due to the low prevalence (1·6 % of the cohort) of severe maternal vitamin D deficiency (defined as of population.

  10. Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mendenhall, Nancy P., E-mail: menden@shands.ufl.edu [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Hoppe, Bradford S.; Nichols, Romaine C.; Mendenhall, William M.; Morris, Christopher G.; Li, Zuofeng; Su, Zhong [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Williams, Christopher R.; Costa, Joseph [Division of Urology, College of Medicine, University of Florida, Jacksonville, Florida (United States); Henderson, Randal H. [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States)

    2014-03-01

    Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes.

  11. Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Mendenhall, Nancy P.; Hoppe, Bradford S.; Nichols, Romaine C.; Mendenhall, William M.; Morris, Christopher G.; Li, Zuofeng; Su, Zhong; Williams, Christopher R.; Costa, Joseph; Henderson, Randal H.

    2014-01-01

    Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes

  12. Effects of Burnable Absorbers on PWR Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    O'Leary, P.M.; Pitts, M.L.

    2000-01-01

    Burnup credit is an ongoing issue in designing and licensing transportation and storage casks for spent nuclear fuel (SNF). To address this issue, in July 1999, the U.S. Nuclear Regulatory Commission (NRC), Spent Fuel Project Office, issued Interim Staff Guidance-8 (ISG-8), Revision 1 allowing limited burnup credit for pressurized water reactor (PWR) spent nuclear fuel (SNF) to be used in transport and storage casks. However, one of the key limitations for a licensing basis analysis as stipulated in ISG-8, Revision 1 is that ''burnup credit is restricted to intact fuel assemblies that have not used burnable absorbers''. Because many PWR fuel designs have incorporated burnable-absorber rods for more than twenty years, this restriction places an unnecessary burden on the commercial nuclear power industry. This paper summarizes the effects of in-reactor irradiation on the isotopic inventory of PWR fuels containing different types of integral burnable absorbers (BAs). The work presented is illustrative and intended to represent typical magnitudes of the reactivity effects from depleting PWR fuel with different types of burnable absorbers

  13. Arctic climate response to forcing from light-absorbing particles in snow and sea ice in CESM

    Directory of Open Access Journals (Sweden)

    N. Goldenson

    2012-09-01

    Full Text Available The presence of light-absorbing aerosol particles deposited on arctic snow and sea ice influences the surface albedo, causing greater shortwave absorption, warming, and loss of snow and sea ice, lowering the albedo further. The Community Earth System Model version 1 (CESM1 now includes the radiative effects of light-absorbing particles in snow on land and sea ice and in sea ice itself. We investigate the model response to the deposition of black carbon and dust to both snow and sea ice. For these purposes we employ a slab ocean version of CESM1, using the Community Atmosphere Model version 4 (CAM4, run to equilibrium for year 2000 levels of CO2 and fixed aerosol deposition. We construct experiments with and without aerosol deposition, with dust or black carbon deposition alone, and with varying quantities of black carbon and dust to approximate year 1850 and 2000 deposition fluxes. The year 2000 deposition fluxes of both dust and black carbon cause 1–2 °C of surface warming over large areas of the Arctic Ocean and sub-Arctic seas in autumn and winter and in patches of Northern land in every season. Atmospheric circulation changes are a key component of the surface-warming pattern. Arctic sea ice thins by on average about 30 cm. Simulations with year 1850 aerosol deposition are not substantially different from those with year 2000 deposition, given constant levels of CO2. The climatic impact of particulate impurities deposited over land exceeds that of particles deposited over sea ice. Even the surface warming over the sea ice and sea ice thinning depends more upon light-absorbing particles deposited over land. For CO2 doubled relative to year 2000 levels, the climate impact of particulate impurities in snow and sea ice is substantially lower than for the year 2000 equilibrium simulation.

  14. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2015-01-01

    Purpose: To evaluate and compare long-term outcomes ofafter photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. Methods: Retrospective single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK...... or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Results: Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.......69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (P=0.31) before surgery. Average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (PPRK eyes and 1 LASEK eye (P=0.46) had lost 2 lines of corrected distance visual acuity...

  15. Clinical spectrum and outcome of pulmonary nocardiosis: 5-year experience

    Directory of Open Access Journals (Sweden)

    Akashdeep Singh

    2016-01-01

    Full Text Available Background: Pulmonary nocardiosis is a rare but a life-threatening infection caused by Nocardia spp. The diagnosis is often missed and delayed resulting in delay in appropriate treatment and thus higher mortality. Aim: In this study, we aim to evaluate the clinical spectrum and outcome of patients with pulmonary nocardiosis. Methods: A retrospective, 5-year (2009-2014 review of demographic profile, risk factors, clinical manifestations, imaging findings, treatment, and outcome of patients with pulmonary nocardiosis admitted to a tertiary care hospital. Results: The median age of the study subjects was 54 years (range, 16-76 and majority of them (75% were males. The risk factors for pulmonary nocardiosis identified in our study were long-term steroid use (55.6%, chronic lung disease (52.8%, diabetes (27.8%, and solid-organ transplantation (22.2%. All the patients were symptomatic, and the most common symptoms were cough (91.7%, fever (78%, and expectoration (72%. Almost two-third of the patients were initially misdiagnosed and the alternative diagnosis included pulmonary tuberculosis (n = 7, community-acquired pneumonia (n = 5, lung abscess (n = 4, invasive fungal infection (n = 3, lung cancer (n = 2, and Wegener′s granulomatosis (n = 2. The most common radiographic features were consolidation (77.8% and nodules (56%. The mortality rate for indoor patients was 33% despite treatment. Higher mortality rate was observed among those who had brain abscess (100.0%, HIV positivity (100%, need for mechanical ventilation (87.5%, solid-organ transplantation (50%, and elderly (age > 60 years patients (43%. Conclusion: The diagnosis of pulmonary nocardiosis is often missed and delayed resulting in delay in appropriate treatment and thus high mortality. A lower threshold for diagnosing pulmonary nocardiosis needs to be exercised, in chest symptomatic patients with underlying chronic lung diseases or systemic immunosuppression, for the early diagnosis, and

  16. Cytokines as a predictor of clinical response following hip arthroscopy: minimum 2-year follow-up.

    Science.gov (United States)

    Shapiro, Lauren M; Safran, Marc R; Maloney, William J; Goodman, Stuart B; Huddleston, James I; Bellino, Michael J; Scuderi, Gaetano J; Abrams, Geoffrey D

    2016-08-01

    Hip arthroscopy in patients with osteoarthritis has been shown to have suboptimal outcomes. Elevated cytokine concentrations in hip synovial fluid have previously been shown to be associated with cartilage pathology. The purpose of this study was to determine whether a relationship exists between hip synovial fluid cytokine concentration and clinical outcomes at a minimum of 2 years following hip arthroscopy. Seventeen patients without radiographic evidence of osteoarthritis had synovial fluid aspirated at time of portal establishment during hip arthroscopy. Analytes included fibronectin-aggrecan complex as well as a multiplex cytokine array. Patients completed the modified Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index and the International Hip Outcomes Tool pre-operatively and at a minimum of 2 years following surgery. Pre and post-operative scores were compared with a paired t-test, and the association between cytokine values and clinical outcome scores was performed with Pearson's correlation coefficient with an alpha value of 0.05 set as significant. Sixteen of seventeen patients completed 2-year follow-up questionnaires (94%). There was a significant increase in pre-operative to post-operative score for each clinical outcome measure. No statistically significant correlation was seen between any of the intra-operative cytokine values and either the 2-year follow-up scores or the change from pre-operative to final follow-up outcome values. No statistically significant associations were seen between hip synovial fluid cytokine concentrations and 2-year follow-up clinical outcome assessment scores for those undergoing hip arthroscopy.

  17. Two-Year Healthy Eating Outcomes: An RCT in Afterschool Programs.

    Science.gov (United States)

    Beets, Michael W; Weaver, R Glenn; Turner-McGrievy, Gabrielle; Huberty, Jennifer; Moore, Justin B; Ward, Dianne S; Freedman, Darcy A; Beighle, Aaron

    2017-09-01

    Across the U.S., afterschool programs (ASPs, 3:00pm-6:00pm) are trying to achieve nationally endorsed nutrition standards (Healthy Eating Standards) calling for fruits/vegetables and water to be served every day, while eliminating sugar-sweetened beverages and foods. The purpose of this study was to evaluate the 2-year changes in the types of foods and beverages served during a community-based intervention designed to achieve the Healthy Eating Standards. Randomized delayed treatment trial with an immediate (1-year baseline and 2-year intervention) or delayed (2-year baseline and 1-year intervention) group. Twenty ASPs serving 1,700 children (aged 5-12 years) were recruited, with baseline occurring spring 2013, and outcome assessment occurring spring 2014 and 2015. The multistep intervention, Strategies To Enhance Practice for Healthy Eating, assisted ASP leaders/staff to serve foods/beverages that meet the nutrition standards. The foods and beverages served for snack were observed directly. Compared with non-intervention years, both the immediate and delayed groups increased the number of days/week that fruits/vegetables (0.6 vs 1.7 days/week and 0.6 vs 4.4 days/week, OR=3.80, 95% CI=1.45, 9.95) and water (2.3 vs 3.7 days/week and 2.7 vs 4.8 days/week, OR=4.65, 95% CI=1.69, 12.79) were served. Sugar-sweetened beverages were almost eliminated by post-assessment (1.2 vs 0.2 days/week and 3.2 vs 0.0 days/week, OR=0.05, 95% CI=0.02, 0.13). Only the immediate group decreased the number of days/week desserts were served (2.9 vs 0.6 days/week, OR=0.10, 95% CI=0.03, 0.33). Implementation barriers for the delayed group included once/month delivery schedules for fruits/vegetables and limited storage space for foods meeting the Healthy Eating Standards. Improvements in the foods/beverages served in ASPs can be made, yet were hindered by structural barriers related to procurement and storage of perishable foods. Additional efforts are needed to support ASPs as they work

  18. Chemically vapor-deposited ZrB/sub 2/ as a selective solar absorber

    Energy Technology Data Exchange (ETDEWEB)

    Randich, E.; Allred, D.D.

    1981-09-25

    Coatings of ZrB/sub 2/ and TiB/sub 2/ for photothermal solar absorber applications were prepared using chemical vapor deposition (CVD) techniques. Oxidation tests suggest a maximum temperature limit for air exposure of 600 K for TiB/sub 2/ and 800 K for ZrB/sub 2/. Both materials exhibit innate spectral selectivity with an emittance at 375 K ranging from 0.06 to 0.09, a solar absorptance for ZrB/sub 2/ ranging from 0.67 to 0.77 and a solar absorptance for TiB/sub 2/ ranging from 0.46 to 0.59. ZrB/sub 2/ has better solar selectivity and more desirable oxidation behavior than TiB/sub 2/. A 0.071 ..mu..m antireflection coating of Si/sub 3/N/sub 4/ deposited onto the ZrB/sub 2/ coating leads to an increase in absorptance from 0.77 to 0.93, while the emittance remains unchanged.

  19. Optimization of sound absorbing performance for gradient multi-layer-assembled sintered fibrous absorbers

    Science.gov (United States)

    Zhang, Bo; Zhang, Weiyong; Zhu, Jian

    2012-04-01

    The transfer matrix method, based on plane wave theory, of multi-layer equivalent fluid is employed to evaluate the sound absorbing properties of two-layer-assembled and three-layer-assembled sintered fibrous sheets (generally regarded as a kind of compound absorber or structures). Two objective functions which are more suitable for the optimization of sound absorption properties of multi-layer absorbers within the wider frequency ranges are developed and the optimized results of using two objective functions are also compared with each other. It is found that using the two objective functions, especially the second one, may be more helpful to exert the sound absorbing properties of absorbers at lower frequencies to the best of their abilities. Then the calculation and optimization of sound absorption properties of multi-layer-assembled structures are performed by developing a simulated annealing genetic arithmetic program and using above-mentioned objective functions. Finally, based on the optimization in this work the thoughts of the gradient design over the acoustic parameters- the porosity, the tortuosity, the viscous and thermal characteristic lengths and the thickness of each samples- of porous metals are put forth and thereby some useful design criteria upon the acoustic parameters of each layer of porous fibrous metals are given while applying the multi-layer-assembled compound absorbers in noise control engineering.

  20. MODERATE C IV ABSORBER SYSTEMS REQUIRE 1012 M☉ DARK MATTER HALOS AT z ∼ 2.3: A CROSS-CORRELATION STUDY OF C IV ABSORBER SYSTEMS AND QUASARS IN SDSS-III BOSS DR9

    International Nuclear Information System (INIS)

    Vikas, Shailendra; Wood-Vasey, W. Michael; Lundgren, Britt; Ross, Nicholas P.; Myers, Adam D.; AlSayyad, Yusra; York, Donald G.; Schneider, Donald P.; Brinkmann, J.; Bizyaev, Dmitry; Brewington, Howard; Malanushenko, Elena; Malanushenko, Viktor; Oravetz, Daniel; Pan, Kaike; Snedden, Stephanie; Ge, Jian; Muna, Demitri; Pâris, Isabelle; Petitjean, Patrick

    2013-01-01

    We measure the two-point cross-correlation function of C IV absorber systems and quasars, using spectroscopic data from the Sloan Digital Sky Survey III Baryon Oscillation Spectroscopic Survey (BOSS; Data Release 9). The 19,701 quasars and 6149 C IV ''moderate'' absorbers, 0.28 Å 2 and represent a factor of two increase in sample size over previous investigations. We find a correlation scale length and slope of the redshift-space cross-correlation function of s 0 = 8.46 ± 1.24 Mpc, γ = 1.68 ± 0.19, in the redshift-space range 10 0 = 7.76 ± 2.80 Mpc, γ = 1.74 ± 0.21. We measure the combined quasar and C IV bias to be b QSO b C I V = 8.81 ± 2.28. Using an estimate of b QSO from the quasar auto-correlation function we find b CIV = 2.38 ± 0.62. This b CIV implies that EW > 0.28 Å C IV absorbers at z ∼ 2.3 are typically found in dark matter halos that have masses ≥10 11.3 -10 13.4 M ☉ at that redshift. The complete BOSS sample will triple the number of both quasars and absorption systems and increase the power of this cross-correlation measurement by a factor of two.

  1. Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

    Energy Technology Data Exchange (ETDEWEB)

    Dufreneix, S.; Ostrowsky, A.; Rapp, B.; Daures, J.; Bordy, J. M., E-mail: jean-marc.bordy@cea.fr [CEA, LIST, Laboratoire National Henri Becquerel (LNE-LNHB), Gif-sur-Yvette F-91191 (France)

    2016-07-15

    Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAP measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.

  2. Evaluation of the distribution of absorbed dose in child phantoms exposed to diagnostic medical x rays

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W. L.; Poston, J. W.; Warner, G. G.

    1978-04-01

    The purpose of this study was to determine, by theoretical calculation and experimental measurement, the absorbed dose distributions in two heterogeneous phantoms representing one-year- and five-year-old children from typical radiographic examinations for those ages. Theoretical work included the modification of an existing internal dose code which uses Monte Carlo methods to determine doses within the Snyder-Fisher mathematical phantom. A Ge(Li) detector and a pinhole collimator were used to measure x-ray spectra which served as input to the modified Monte Carlo codes which were used to calculate organ doses in children. The calculated and measured tissue-air values were compared for a number of organs. For most organs, the results of the calculated absorbed doses agreed with the measured absorbed doses within twice the coefficient of variation of the calculated value. The absorbed dose to specific organs for several selected radiological examinations are given for one-year-old, five-year-old, and adult phantoms.

  3. Evaluation of the distribution of absorbed dose in child phantoms exposed to diagnostic medical x rays

    International Nuclear Information System (INIS)

    Chen, W.L.; Poston, J.W.; Warner, G.G.

    1978-04-01

    The purpose of this study was to determine, by theoretical calculation and experimental measurement, the absorbed dose distributions in two heterogeneous phantoms representing one-year- and five-year-old children from typical radiographic examinations for those ages. Theoretical work included the modification of an existing internal dose code which uses Monte Carlo methods to determine doses within the Snyder-Fisher mathematical phantom. A Ge(Li) detector and a pinhole collimator were used to measure x-ray spectra which served as input to the modified Monte Carlo codes which were used to calculate organ doses in children. The calculated and measured tissue-air values were compared for a number of organs. For most organs, the results of the calculated absorbed doses agreed with the measured absorbed doses within twice the coefficient of variation of the calculated value. The absorbed dose to specific organs for several selected radiological examinations are given for one-year-old, five-year-old, and adult phantoms

  4. Cognitive functioning over 2 years after intracerebral hemorrhage in school-aged children.

    Science.gov (United States)

    Murphy, Lexa K; Compas, Bruce E; Gindville, Melissa C; Reeslund, Kristen L; Jordan, Lori C

    2017-11-01

    Previous research investigating outcomes after pediatric intracerebral hemorrhage (ICH) has generally been limited to global and sensorimotor outcomes. This study examined cognitive outcomes after spontaneous ICH in school-aged children with serial assessments over 2 years after stroke. Seven children (age range 6-16y, median 13; six males, one female; 57% white, 43% black) presenting with spontaneous ICH (six arteriovenous malformations) were assessed at 3 months, 12 months, and 24 months after stroke. The Pediatric Stroke Outcome Measure (PSOM) quantified neurological outcome and Wechsler Intelligence Scales measured cognitive outcomes: verbal comprehension, perceptual reasoning, working memory, and processing speed. PSOM scales showed improved neurological function over the first 12 months, with mild to no sensorimotor deficits and moderate overall deficits at 1- and 2-year follow-ups (median 2-year sensorimotor PSOM=0.5, total PSOM=1.5). Changes in cognitive function indicated a different trajectory; verbal comprehension and perceptual reasoning improved over 24 months; low performance was sustained in processing speed and working memory. Age-normed centile scores decreased between 1- and 2-year follow-ups for working memory, suggesting emerging deficits compared with peers. Early and serial cognitive testing in children with ICH is needed to assess cognitive functioning and support children in school as they age and cognitive deficits become more apparent and important for function. In children with intracerebral hemorrhage (ICH), motor function improved between 3 months and 24 months. Improvements in cognitive function were variable between 3 months and 24 months. Working memory centiles declined, suggesting emerging deficits compared with peers. Processing speed improved but remained significantly below the 50th centile. Cognitive impact of ICH may increase with age in children. © 2017 Mac Keith Press.

  5. Cumulative risk, cumulative outcome: a 20-year longitudinal study.

    Directory of Open Access Journals (Sweden)

    Leslie Atkinson

    Full Text Available Cumulative risk (CR models provide some of the most robust findings in the developmental literature, predicting numerous and varied outcomes. Typically, however, these outcomes are predicted one at a time, across different samples, using concurrent designs, longitudinal designs of short duration, or retrospective designs. We predicted that a single CR index, applied within a single sample, would prospectively predict diverse outcomes, i.e., depression, intelligence, school dropout, arrest, smoking, and physical disease from childhood to adulthood. Further, we predicted that number of risk factors would predict number of adverse outcomes (cumulative outcome; CO. We also predicted that early CR (assessed at age 5/6 explains variance in CO above and beyond that explained by subsequent risk (assessed at ages 12/13 and 19/20. The sample consisted of 284 individuals, 48% of whom were diagnosed with a speech/language disorder. Cumulative risk, assessed at 5/6-, 12/13-, and 19/20-years-old, predicted aforementioned outcomes at age 25/26 in every instance. Furthermore, number of risk factors was positively associated with number of negative outcomes. Finally, early risk accounted for variance beyond that explained by later risk in the prediction of CO. We discuss these findings in terms of five criteria posed by these data, positing a "mediated net of adversity" model, suggesting that CR may increase some central integrative factor, simultaneously augmenting risk across cognitive, quality of life, psychiatric and physical health outcomes.

  6. [Occupational outcome of patients with schizophrenia after first request for disability status: a 2-year follow-up study].

    Science.gov (United States)

    Verdoux, H; Goumilloux, R; Monello, F; Cougnard, A

    2010-12-01

    To assess occupational outcome of persons with schizophrenia over the 2 years following the first request of disability status. This study was carried out in collaboration with the Commission Technique d'Orientation et de Reclassement Professionnel (COTOREP) (technical commission for occupational guidance and rehabilitation of the disabled) de la Gironde (Bordeaux region, South Western France). Persons with schizophrenia or schizoaffective disorder requesting for the first time in 2006 a disability allowance or the status of disabled worker were assessed using a standardized questionnaire collecting data on clinical, occupational and income history. Information on occupational outcome over the 2 years after the first request was collected at the end of the follow-up using multiple sources of information. We used a broad definition of work, including moonlighting and episodic activities (baby-sitting or grape-harvesting), as well as study periods. Of the 121 patients included at baseline, direct or indirect information was available for 108 (90%) at the 24-month assessment. Persons lost to follow-up were less likely to have worked before first request of disability status compared to persons with information available at the end of the follow-up, but did not differ regarding the other characteristics. Nearly half of the persons (41.7%) had worked over the follow-up, irrespective of the type and duration of the occupation. The working periods were of short duration (median duration 14.5 days, interquartile range 6.5-47.5) and most (98%) were done in low-qualified jobs. Nearly half of the persons reported that they had benefitted from support for starting or returning to work, mainly from recruitment agencies specialized in supporting disabled workers. Persons with the status of disabled worker (Reconnaissance de la qualité de travailleur handicapé) (RTH) were more likely to have worked over the follow-up period (66.7% vs 33.3%; OR=3.9; 95%IC 1.3-11.3; pself

  7. DOC-2/DAB2 Interacting Protein Status in High-Risk Prostate Cancer Correlates With Outcome for Patients Treated With Radiation Therapy

    International Nuclear Information System (INIS)

    Jacobs, Corbin; Tumati, Vasu; Kapur, Payal; Yan, Jingsheng; Hong, David; Bhuiyan, Manzerul; Xie, Xian-Jin; Pistenmaa, David; Yu, Lan; Hsieh, Jer-Tsong; Saha, Debabrata; Kim, D. W. Nathan

    2014-01-01

    Purpose: This pilot study investigates the role of DOC-2/DAB2 Interacting Protein (DAB2IP) and enhancer of zeste homolog 2 (EZH2) as prognostic biomarkers in high-risk prostate cancer patients receiving definitive radiation therapy. Methods and Materials: Immunohistochemistry was performed and scored by an expert genitourinary pathologist. Clinical endpoints evaluated were freedom from biochemical failure (FFBF), castration resistance–free survival (CRFS), and distant metastasis–free survival (DMFS). Log-rank test and Cox regression were used to determine significance of biomarker levels with clinical outcome. Results: Fifty-four patients with high-risk prostate cancer (stage ≥T3a, or Gleason score ≥8, or prostate-specific antigen level ≥20 ng/mL) treated with radiation therapy from 2005 to 2012 at our institution were evaluated. Nearly all patients expressed EZH2 (98%), whereas 28% of patients revealed DAB2IP reduction and 72% retained DAB2IP. Median follow-up was 34.0 months for DAB2IP-reduced patients, 29.9 months for DAB2IP-retained patients, and 32.6 months in the EZH2 study. Reduction in DAB2IP portended worse outcome compared with DAB2IP-retained patients, including FFBF (4-year: 37% vs 89%, P=.04), CRFS (4-year: 50% vs 90%, P=.02), and DMFS (4-year: 36% vs 97%, P=.05). Stratified EZH2 expression trended toward significance for worse FFBF and CRFS (P=.07). Patients with reduced DAB2IP or highest-intensity EZH2 expression exhibited worse FFBF (4-year: 32% vs 95%, P=.02), CRFS (4-year: 28% vs 100%, P<.01), and DMFS (4-year: 39% vs 100%, P=.04) compared with the control group. Conclusion: Loss of DAB2IP is a potent biomarker that portends worse outcome despite definitive radiation therapy for patients with high-risk prostate cancer. Enhancer of zeste homolog 2 is expressed in most high-risk tumors and is a less potent discriminator of outcome in this study. The DAB2IP status in combination with degree of EZH2 expression may be useful for

  8. DOC-2/DAB2 Interacting Protein Status in High-Risk Prostate Cancer Correlates With Outcome for Patients Treated With Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Corbin; Tumati, Vasu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Kapur, Payal [Department of Pathology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Yan, Jingsheng [Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Hong, David; Bhuiyan, Manzerul [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Xie, Xian-Jin [Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Pistenmaa, David [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Simmons Cancer Center, Dallas, Texas (United States); Yu, Lan [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Hsieh, Jer-Tsong [Simmons Cancer Center, Dallas, Texas (United States); Department of Urology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Saha, Debabrata [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Simmons Cancer Center, Dallas, Texas (United States); Kim, D. W. Nathan, E-mail: Nathan.Kim@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Simmons Cancer Center, Dallas, Texas (United States)

    2014-07-15

    Purpose: This pilot study investigates the role of DOC-2/DAB2 Interacting Protein (DAB2IP) and enhancer of zeste homolog 2 (EZH2) as prognostic biomarkers in high-risk prostate cancer patients receiving definitive radiation therapy. Methods and Materials: Immunohistochemistry was performed and scored by an expert genitourinary pathologist. Clinical endpoints evaluated were freedom from biochemical failure (FFBF), castration resistance–free survival (CRFS), and distant metastasis–free survival (DMFS). Log-rank test and Cox regression were used to determine significance of biomarker levels with clinical outcome. Results: Fifty-four patients with high-risk prostate cancer (stage ≥T3a, or Gleason score ≥8, or prostate-specific antigen level ≥20 ng/mL) treated with radiation therapy from 2005 to 2012 at our institution were evaluated. Nearly all patients expressed EZH2 (98%), whereas 28% of patients revealed DAB2IP reduction and 72% retained DAB2IP. Median follow-up was 34.0 months for DAB2IP-reduced patients, 29.9 months for DAB2IP-retained patients, and 32.6 months in the EZH2 study. Reduction in DAB2IP portended worse outcome compared with DAB2IP-retained patients, including FFBF (4-year: 37% vs 89%, P=.04), CRFS (4-year: 50% vs 90%, P=.02), and DMFS (4-year: 36% vs 97%, P=.05). Stratified EZH2 expression trended toward significance for worse FFBF and CRFS (P=.07). Patients with reduced DAB2IP or highest-intensity EZH2 expression exhibited worse FFBF (4-year: 32% vs 95%, P=.02), CRFS (4-year: 28% vs 100%, P<.01), and DMFS (4-year: 39% vs 100%, P=.04) compared with the control group. Conclusion: Loss of DAB2IP is a potent biomarker that portends worse outcome despite definitive radiation therapy for patients with high-risk prostate cancer. Enhancer of zeste homolog 2 is expressed in most high-risk tumors and is a less potent discriminator of outcome in this study. The DAB2IP status in combination with degree of EZH2 expression may be useful for

  9. Sound Absorbers

    Science.gov (United States)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  10. Structural investigation and microwave characteristics of (Ba{sub 0.2}La{sub 0.8})Fe{sub 0.2}Mn{sub 0.4}Ti{sub 0.4}O{sub 3} absorbing materials

    Energy Technology Data Exchange (ETDEWEB)

    Manaf, Azwar [Dept. of Physics, Faculty of Mathematics and Natural Sciences, Indonesia of University (Indonesia); Adi, Wisnu Ari, E-mail: dwisnuaa@batan.go.id [Center for Technology of Nuclear Industry Material, National Nuclear Energy Agency (Indonesia)

    2014-03-24

    Synthesis and characterization of (Ba{sub 0.2}La{sub 0.8})Fe{sub 0.2}Mn{sub 0.4}Ti{sub 0.4}O{sub 3} absorbing material by mechanical alloying process has been performed. The absorbing material was prepared by oxide materials, namely BaCO{sub 3}, La{sub 2}O{sub 3}, TiO{sub 2}, Fe{sub 2}O{sub 3}, and MnCO{sub 3}. The mixture was milled for 10 h and then sintered at a temperature of 1000 ° C for 10 h. The refinement results of x-ray diffraction pattern of lanthanum manganite substituted with barium showed that the sample consisted of two phases, namely, La{sub 0.9125}MnO{sub 3} phase which has a structure monoclinic (I12/a1) with lattice parameters a = 5.527(1) Å, b = 5.572(1) Å and c = 7.810(1) Å, α = γ = 90° and β = 89.88(5)°, the unit cell volume of V = 240.57(8) Å{sup 3}, and the atomic density of ρ = 6.238 gr.cm{sup −3}. The microstructure analyses showed that the particle shapes was polygonal with the varied particle sizes of 1 ∼ 3 μm distributed homogeneously on the surface of the samples. The results of the electromagnetic wave absorption curve analysis by using a vector network analyzer (VNA) showed that the sample can absorb microwaves in the frequency range of 8-15 GHz with a very wide absorption bandwidth. It indicates that the as prepared absorber presents potential absorbing property in X and Ku-band. We concluded that the (Ba{sub 0.2}La{sub 0.8})Fe{sub 0.2}Mn{sub 0.4}Ti{sub 0.4}O{sub 3} material can be applied as a candidate absorber material of microwaves or electromagnetic wave.

  11. Group cognitive behavioral therapy for patients with generalized social anxiety disorder in Japan: outcomes at 1-year follow up and outcome predictors

    Directory of Open Access Journals (Sweden)

    Kawaguchi A

    2013-02-01

    Full Text Available Akiko Kawaguchi,1 Norio Watanabe,1 Yumi Nakano,2 Sei Ogawa,1 Masako Suzuki,1 Masaki Kondo,1 Toshi A Furukawa,3 Tatsuo Akechi11Department of Psychiatry and Cognitive-Behavioral Medicine, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan; 2Sugiyama Jogakuen University School of Human Sciences, Nisshin, Japan; 3Department of Health Promotion and Human Behavior, Kyoto University Graduate School of Medicine/School of Public Health, Kyoto, JapanBackground: Social anxiety disorder (SAD is one of the most common psychiatric disorders worldwide. Cognitive behavioral therapy (CBT is an effective treatment option for patients with SAD. In the present study, we examined the efficacy of group CBT for patients with generalized SAD in Japan at 1-year follow-up and investigated predictors with regard to outcomes.Methods: This study was conducted as a single-arm, naturalistic, follow-up study in a routine Japanese clinical setting. A total of 113 outpatients with generalized SAD participated in group CBT from July 2003 to August 2010 and were assessed at follow-ups for up to 1 year. Primary outcome was the total score on the Social Phobia Scale/Social Interaction Anxiety Scale (SPS/SIAS at 1 year. Possible baseline predictors were investigated using mixed-model analyses.Results: Among the 113 patients, 70 completed the assessment at the 1-year follow-up. The SPS/SIAS scores showed significant improvement throughout the follow-ups for up to 1 year. The effect sizes of SPS/SIAS at the 1-year follow-up were 0.68 (95% confidence interval 0.41–0.95/0.76 (0.49–1.03 in the intention-to-treat group and 0.77 (0.42–1.10/0.84 (0.49–1.18 in completers. Older age at baseline, late onset, and lower severity of SAD were significantly associated with good outcomes as a result of mixed-model analyses.Conclusions: CBT for patients with generalized SAD in Japan is effective for up to 1 year after treatment. The effect sizes were as large as those in

  12. Neutron absorbing article

    International Nuclear Information System (INIS)

    Naum, R.G.; Owens, D.P.; Dooher, G.I.

    1979-01-01

    A neutron absorbing article, in flat plate form and suitable for use in a storage rack for spent fuel, includes boron carbide particles, diluent particles and a solid, irreversibly cured phenolic polymer cured to a continuous matrix binding the boron carbide and diluent particles. The total conent of boron carbide and diluent particles is a major proportion of the article and the content of cured phenolic polymer present is a minor proportion. By regulation of the ratio of boron carbide particles to diluent particles, normally within the range of 1:9 and 9:1 and preferably within the range of 1:5 to 5:1, the neutron absorbing activity of the product may be controlled, which facilitates the manufacture of articles of particular absorbing activities best suitable for specific applications

  13. Effect of thermal annealing in vacuum on the photovoltaic properties of electrodeposited Cu2O-absorber solar cell

    Directory of Open Access Journals (Sweden)

    Dimopoulos T.

    2014-07-01

    Full Text Available Heterojunction solar cells were fabricated by electrochemical deposition of p-type, cuprous oxide (Cu2O absorber on sputtered, n-type ZnO layer. X-ray diffraction measurements revealed that the as-deposited absorber consists mainly of Cu2O, but appreciable amounts of metallic Cu and cupric oxide (CuO are also present. These undesired oxidation states are incorporated during the deposition process and have a detrimental effect on the photovoltaic properties of the cells. The open circuit voltage (VOC, short circuit current density (jSC, fill factor (FF and power conversion efficiency (η of the as-deposited cells are 0.37 V, 3.71 mA/cm2, 35.7% and 0.49%, respectively, under AM1.5G illumination. We show that by thermal annealing in vacuum, at temperatures up to 300 °C, compositional purity of the Cu2O absorber could be obtained. A general improvement of the heterojunction and bulk materials quality is observed, reflected upon the smallest influence of the shunt and series resistance on the transport properties of the cells in dark and under illumination. Independent of the annealing temperature, transport is dominated by the space-charge layer generation-recombination current. After annealing at 300 °C the solar cell parameters could be significantly improved to the values of: VOC = 0.505 V, jSC = 4.67 mA/cm2, FF = 47.1% and η = 1.12%.

  14. Degradation and mineralization of organic UV absorber compound 2-phenylbenzimidazole-5-sulfonic acid (PBSA) using UV-254 nm/H{sub 2}O{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Abdelraheem, Wael H.M. [Chemistry Department, Faculty of Science, Sohag University, Sohag 82524 (Egypt); Environmental Engineering and Science Program, University of Cincinnati, Cincinnati, OH 45221-0012 (United States); He, Xuexiang; Duan, Xiaodi [Environmental Engineering and Science Program, University of Cincinnati, Cincinnati, OH 45221-0012 (United States); NIREAS-International Water Research Center, University of Cyprus, Nicosia 1678 (Cyprus); Dionysiou, Dionysios D., E-mail: dionysios.d.dionysiou@uc.edu [Environmental Engineering and Science Program, University of Cincinnati, Cincinnati, OH 45221-0012 (United States); NIREAS-International Water Research Center, University of Cyprus, Nicosia 1678 (Cyprus)

    2015-01-23

    Graphical abstract: - Highlights: • UV-254 nm/H{sub 2}O{sub 2} AOP was utilized for the degradation and mineralization of PBSA and BSA. • Promotion of k{sub obs} with [H{sub 2}O{sub 2}]{sub 0} ≤ 4 mM and inhibition at higher [H{sub 2}O{sub 2}]{sub 0} were observed. • The S and N were released and monitored as SO{sub 4}{sup 2−} and NH{sub 4}{sup +}, respectively. • Br{sup −} inhibited both the degradation and mineralization much more significantly than Cl{sup −}. • There was an increase in [NH{sub 4}{sup +}] at higher [H{sub 2}O{sub 2}]{sub 0} and its further destruction at higher UV fluence. - Abstract: Various studies have revealed the non-biodegradable and endocrine disrupting properties of sulfonated organic UV absorbers, directing people's attention toward their risks on ecological and human health and hence their removal from water. In this study, UV-254 nm/H{sub 2}O{sub 2} advanced oxidation process (AOP) was investigated for degrading a model UV absorber compound 2-phenylbenzimidazole-5-sulfonic acid (PBSA) and a structurally similar compound 1H-benzimidazole-2-sulfonic acid (BSA), with a specific focus on their mineralization. At 4.0 mM [H{sub 2}O{sub 2}]{sub 0}, a complete removal of 40.0 μM parent PBSA and 25% decrease in TOC were achieved with 190 min of UV irradiation; SO{sub 4}{sup 2−} was formed and reached its maximum level while the release of nitrogen as NH{sub 4}{sup +} was much lower (around 50%) at 190 min. Sulfate removal was strongly enhanced by increasing [H{sub 2}O{sub 2}]{sub 0} in the range of 0–4.0 mM, with slight inhibition in 4.0–12.0 mM. Faster and earlier ammonia formation was observed at higher [H{sub 2}O{sub 2}]{sub 0}. The presence of Br{sup −} slowed down the degradation and mineralization of both compounds while a negligible effect on the degradation was observed in the presence of Cl{sup −}. Our study provides important technical and fundamental results on the HO{sup ·} based degradation and

  15. Large flux change due to the intervening cold absorbers in NGC 3516

    International Nuclear Information System (INIS)

    Nogami, K.; Negoro, H.; Hong, S.; Mihara, T.

    2004-01-01

    NGC3516 in the low flux state shows a flat energy spectrum (photon index ∼1) and an intense narrow iron line. Such spectra are also observed in other Seyfert galaxies, and a broad bump structure around 6 keV above the 'flat' power-law spectrum has been interpreted as the gravitationally red-shifted iron line, disk reflection, or cold and/or warm absorbers. However, six years if BeppoSAX observations, including our latest three ones in 2001, clearly demonstrate that energy spectra above 20 keV always exhibit steep power-laws with photon indices ∼2, and the flux changes only by a factor of 2, while the soft X-ray flux by a factor of ∼10. From this fact, using BeppoSAX and ASCA data, we have concluded that the flat spectrum results from reprocessed, and partially covered power-laws with Γ∼1.8 by warm matter nearby the central source and a cold absorber moved in the line of sight, respectively, and that the broad iron line and disk reflection components are less significant than one ever thought. Thus, the long-term spectral variations can be considered by intervening absorbers rather than changes in the accretion rate

  16. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  17. Ni-Al Alloys as Alternative EUV Mask Absorber

    Directory of Open Access Journals (Sweden)

    Vu Luong

    2018-03-01

    Full Text Available Extreme ultraviolet (EUV lithography is being industrialized as the next candidate printing technique for high-volume manufacturing of scaled down integrated circuits. At mask level, the combination of EUV light at oblique incidence, absorber thickness, and non-uniform mirror reflectance through incidence angle, creates photomask-induced imaging aberrations, known as mask 3D (M3D effects. A possible mitigation for the M3D effects in the EUV binary intensity mask (BIM, is to use mask absorber materials with high extinction coefficient κ and refractive coefficient n close to unity. We propose nickel aluminide alloys as a candidate BIM absorber material, and characterize them versus a set of specifications that a novel EUV mask absorber must meet. The nickel aluminide samples have reduced crystallinity as compared to metallic nickel, and form a passivating surface oxide layer in neutral solutions. Composition and density profile are investigated to estimate the optical constants, which are then validated with EUV reflectometry. An oxidation-induced Al L2 absorption edge shift is observed, which significantly impacts the value of n at 13.5 nm wavelength and moves it closer to unity. The measured optical constants are incorporated in an accurate mask model for rigorous simulations. The M3D imaging impact of the nickel aluminide alloy mask absorbers, which predict significant M3D reduction in comparison to reference absorber materials. In this paper, we present an extensive experimental methodology flow to evaluate candidate mask absorber materials.

  18. A multicenter randomized controlled trial comparing absorbable barbed sutures versus conventional absorbable sutures for dermal closure in open surgical procedures.

    Science.gov (United States)

    Rubin, J Peter; Hunstad, Joseph P; Polynice, Alain; Gusenoff, Jeffrey A; Schoeller, Thomas; Dunn, Raymond; Walgenbach, Klaus J; Hansen, Juliana E

    2014-02-01

    Barbed sutures were developed to reduce operative time and improve security of wound closure. The authors compare absorbable barbed sutures (V-Loc, Covidien, Mansfield, Massachusetts) with conventional (smooth) absorbable sutures for soft tissue approximation. A prospective multicenter randomized study comparing barbed sutures with smooth sutures was undertaken between August 13, 2009, and January 31, 2010, in 241 patients undergoing abdominoplasty, mastopexy, and reduction mammaplasty. Each patient received barbed sutures on 1 side of the body, with deep dermal sutures eliminated or reduced. Smooth sutures with deep dermal and subcuticular closure were used on the other side as a control. The primary endpoint was dermal closure time. Safety was assessed through adverse event reporting through a 12-week follow-up. A total of 229 patients were ultimately treated (115 with slow-absorbing polymer and 114 with rapid-absorbing polymer). Mean dermal closure time was significantly quicker with the barbed suture compared with the smooth suture (12.0 vs 19.2 minutes; P<.001), primarily due to the need for fewer deep dermal sutures. The rapid-absorbing barbed suture showed a complication profile equivalent to the smooth suture, while the slow-absorbing barbed suture had a higher incidence of minor suture extrusion. Barbed sutures enabled faster dermal closure quicker than smooth sutures, with a comparable complication profile. 1.

  19. Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH{sub 3}/H{sub 2}O Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Young; Kim, Min Sung; Baik, Young Jin; Park, Seong Ryong; Chang, Ki Chang; Ra, Ho Sang [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Kim, Yong Chan [Korea University, Seoul (Korea, Republic of)

    2011-03-15

    This research aims to develop a compression/absorption hybrid heat pump system using an NH{sub 3}/H{sub 2}O as working fluid. The heat pump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a de superheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above 90 .deg. C using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangement of the plate heat exchangers with regard to the concentration and distribution at the inlet of the absorber.

  20. Mortality and One-Year Functional Outcome in Elderly and Very Old Patients with Severe Traumatic Brain Injuries: Observed and Predicted

    Directory of Open Access Journals (Sweden)

    Cecilie Røe

    2015-01-01

    Full Text Available The aim of the present study was to evaluate mortality and functional outcome in old and very old patients with severe traumatic brain injury (TBI and compare to the predicted outcome according to the internet based CRASH (Corticosteroid Randomization After Significant Head injury model based prediction, from the Medical Research Council (MRC. Methods. Prospective, national multicenter study including patients with severe TBI ≥65 years. Predicted mortality and outcome were calculated based on clinical information (CRASH basic (age, GCS score, and pupil reactivity to light, as well as with additional CT findings (CRASH CT. Observed 14-day mortality and favorable/unfavorable outcome according to the Glasgow Outcome Scale at one year was compared to the predicted outcome according to the CRASH models. Results. 97 patients, mean age 75 (SD 7 years, 64% men, were included. Two patients were lost to follow-up; 48 died within 14 days. The predicted versus the observed odds ratio (OR for mortality was 2.65. Unfavorable outcome (GOSE < 5 was observed at one year follow-up in 72% of patients. The CRASH models predicted unfavorable outcome in all patients. Conclusion. The CRASH model overestimated mortality and unfavorable outcome in old and very old Norwegian patients with severe TBI.

  1. Mortality and One-Year Functional Outcome in Elderly and Very Old Patients with Severe Traumatic Brain Injuries: Observed and Predicted

    Science.gov (United States)

    Røe, Cecilie; Skandsen, Toril; Manskow, Unn; Ader, Tiina; Anke, Audny

    2015-01-01

    The aim of the present study was to evaluate mortality and functional outcome in old and very old patients with severe traumatic brain injury (TBI) and compare to the predicted outcome according to the internet based CRASH (Corticosteroid Randomization After Significant Head injury) model based prediction, from the Medical Research Council (MRC). Methods. Prospective, national multicenter study including patients with severe TBI ≥65 years. Predicted mortality and outcome were calculated based on clinical information (CRASH basic) (age, GCS score, and pupil reactivity to light), as well as with additional CT findings (CRASH CT). Observed 14-day mortality and favorable/unfavorable outcome according to the Glasgow Outcome Scale at one year was compared to the predicted outcome according to the CRASH models. Results. 97 patients, mean age 75 (SD 7) years, 64% men, were included. Two patients were lost to follow-up; 48 died within 14 days. The predicted versus the observed odds ratio (OR) for mortality was 2.65. Unfavorable outcome (GOSE < 5) was observed at one year follow-up in 72% of patients. The CRASH models predicted unfavorable outcome in all patients. Conclusion. The CRASH model overestimated mortality and unfavorable outcome in old and very old Norwegian patients with severe TBI. PMID:26688614

  2. Absorber Model: the Halo-like model for the Lyman-α forest

    Science.gov (United States)

    Iršič, Vid; McQuinn, Matthew

    2018-04-01

    We present a semi-analytic model for the Lyman-α forest that is inspired by the Halo Model. This model is built on the absorption line decomposition of the forest. Flux correlations are decomposed into those within each absorption line (the 1-absorber term) and those between separate lines (the 2-absorber term), treating the lines as biased tracers of the underlying matter fluctuations. While the nonlinear exponential mapping between optical depth and flux requires an infinite series of moments to calculate any statistic, we show that this series can be re-summed (truncating at the desired order in the linear matter overdensity). We focus on the z=2–3 line-of-sight power spectrum. Our model finds that 1-absorber term dominates the power on all scales, with most of its contribution coming from H I columns of 1014–1015 cm‑2, while the smaller 2-absorber contribution comes from lower columns that trace overdensities of a few. The prominence of the 1-absorber correlations indicates that the line-of-sight power spectrum is shaped principally by the lines' number densities and their absorption profiles, with correlations between lines contributing to a lesser extent. We present intuitive formulae for the effective optical depth as well as the large-scale limits of 1-absorber and 2-absorber terms, which simplify to integrals over the H I column density distribution with different equivalent-width weightings. With minimalist models for the bias of absorption systems and their peculiar velocity broadening, our model predicts values for the density bias and velocity gradient bias that are consistent with those found in simulations.

  3. PATIENT - 2 year report (2013 - 2014) public version

    NARCIS (Netherlands)

    Drachsler, Hendrik; Henn, Patrick; Hynes, Helen; Stieger, Lina; Schroeder, Hanna; Sopka, Sasa; Hartkopf, Kathleen; Orrego, Carola

    2014-01-01

    This report extends the first project report with a summary of the latest activities of the second year of the PATIENT project. The first report provided an overview about empirical studies of the stakeholder needs, as conducted in WP2, and the target learning outcomes of the handover study

  4. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  5. Integration of regenerative shock absorber into vehicle electric system

    Science.gov (United States)

    Zhang, Chongxiao; Li, Peng; Xing, Shaoxu; Kim, Junyoung; Yu, Liangyao; Zuo, Lei

    2014-03-01

    Regenerative/Energy harvesting shock absorbers have a great potential to increase fuel efficiency and provide suspension damping simultaneously. In recent years there's intensive work on this topic, but most researches focus on electricity extraction from vibration and harvesting efficiency improvement. The integration of electricity generated from regenerative shock absorbers into vehicle electric system, which is very important to realize the fuel efficiency benefit, has not been investigated. This paper is to study and demonstrate the integration of regenerative shock absorber with vehicle alternator, battery and in-vehicle electrical load together. In the presented system, the shock absorber is excited by a shaker and it converts kinetic energy into electricity. The harvested electricity flows into a DC/DC converter which realizes two functions: controlling the shock absorber's damping and regulating the output voltage. The damping is tuned by controlling shock absorber's output current, which is also the input current of DC/DC converter. By adjusting the duty cycles of switches in the converter, its input impedance together with input current can be adjusted according to dynamic damping requirements. An automotive lead-acid battery is charged by the DC/DC converter's output. To simulate the working condition of combustion engine, an AC motor is used to drive a truck alternator, which also charges the battery. Power resistors are used as battery's electrical load to simulate in-vehicle electrical devices. Experimental results show that the proposed integration strategy can effectively utilize the harvested electricity and power consumption of the AC motor is decreased accordingly. This proves the combustion engine's load reduction and fuel efficiency improvement.

  6. FIVE-YEAR OUTCOMES OF INTRAVITREAL RANIBIZUMAB FOR CHOROIDAL NEOVASCULARIZATION IN PATIENTS WITH PATHOLOGIC MYOPIA.

    Science.gov (United States)

    Onishi, Yuka; Yokoi, Tae; Kasahara, Kaori; Yoshida, Takeshi; Nagaoka, Natsuko; Shinohara, Kosei; Kaneko, Yuichiro; Suga, Mitsuki; Uramoto, Kengo; Ohno-Tanaka, Akiko; Ohno-Matsui, Kyoko

    2018-05-03

    To determine the 5-year outcome of intravitreal ranibizumab (IVR) for myopic choroidal neovascularization (CNV). We retrospectively analyzed the medical records of 51 eyes of 51 consecutive patients with myopic CNV who had been treated with IVR with a minimum follow-up period of 5 years after the initial IVR injection. The factors that predicted the best-corrected visual acuity (BCVA) at 5 years after IVR were determined by multiple regression analysis. The mean age of the subjects was 63.6 years, and the mean axial length was 29.4 mm. The mean number of IVR was 1.6, and 34 eyes (66.7%) had only a single IVR. At the baseline and at the 1-year, 2-year, 4-year, and 5-year period, the mean BCVAs were 20/49, 20/37, 20/41, 20/45, and 20/42, respectively. Stepwise multiple regression analysis showed that the BCVA at 5-year period was significantly correlated with the baseline BCVA, the number of IVR injections, and the size of the CNV-related macular atrophy. Intravitreal ranibizumab provide a 5-year visual benefit in eyes with myopic CNV compared with the natural course. A lack of enlargement of the CNV-related macular atrophy, a better baseline BCVA, and a minimum number of IVR injections were associated with better visual outcomes.

  7. Childhood Rabies: A 10 Year Review of Management and Outcome ...

    African Journals Online (AJOL)

    Background: Rabies is still a cause of death among children in our environment. We undertook a 10-year retrospective review to evaluate the aetiology and outcome of management of childhood rabies in our setting. Methodology: This was a 10-year retrospective study of rabies cases managed in the Paediatrics Unit of the ...

  8. Five-year Treatment Outcomes in the Ahmed Baerveldt Comparison Study

    Science.gov (United States)

    Budenz, Donald L.; Barton, Keith; Gedde, Steven J.; Feuer, William J.; Schiffman, Joyce; Costa, Vital P.; Godfrey, David G.; Buys, Yvonne M.

    2014-01-01

    Purpose To compare the five year outcomes of the Ahmed FP7 Glaucoma Valve (AGV) and the Baerveldt 101-350 Glaucoma Implant (BGI) for the treatment of refractory glaucoma. Design Multicenter randomized controlled clinical trial. Participants 276 patients, including 143 in the AGV group and 133 in the BGI group. Methods Patients 18 to 85 years of age with previous intraocular surgery or refractory glaucoma and intraocular pressure (IOP) of ≥ 18 mmHg in whom glaucoma drainage implant surgery was planned were randomized to implantation of either an AGV or BGI. Main Outcome Measures IOP, visual acuity, use of glaucoma medications, complications, and failure (IOP > 21 mmHg or not reduced by 20% from baseline, IOP ≤ 5 mmHg, reoperation for glaucoma, removal of implant, or loss of light perception). Results At 5 years, IOP (mean ± SD) was 14.7 ± 4.4 mmHg in the AGV group and 12.7 ± 4.5 mmHg in the BGI group (p = 0.012). The number of glaucoma medications in use at 5 years (mean ± SD) was 2.2 ± 1.4 in the AGV group and 1.8 ± 1.5 in the BGI group (p = 0.28). The cumulative probability of failure during 5 years of follow-up was 44.7% in the AGV group and 39.4% in the BGI group (p = 0.65). The number of subjects failing due to inadequately controlled IOP or reoperation for glaucoma was 46 in the AGV group (80% of AGV failures) and 25 in the BGI group (53% of BGI failures, p=0.003). Eleven AGV eyes (20% of AGV failures) experienced persistent hypotony, explantation of implant, or loss of light perception compared to 22 (47% of failures) in the BGI group. The 5-year cumulative reoperation rate for glaucoma was 20.8% in the AGV group compared to 8.6% in the BGI group (p=0.010). Change in logMAR Snellen visual acuity (mean ± SD) at 5 years was 0.42 ± 0.99 in the AGV group and 0.43 ± 0.84 in the BGI group (p=0.97). Conclusions Similar rates of surgical success were observed with both implants at 5 years. BGI implantation produced greater IOP reduction and a lower rate

  9. Outcome quality and long-term (≥15 years) stability after Class II:2 Herbst-multibracket appliance treatment in comparison to untreated Class I controls.

    Science.gov (United States)

    Bock, Niko C; Saffar, Mitra; Hudel, Helge; Evälahti, Marjut; Heikinheimo, Kaisa; Rice, David P; Ruf, Sabine

    2017-12-09

    To investigate the outcome quality and the long-term (≥15 years) post-treatment (Tx) changes after Class II:2 Herbst-multibracket appliance (MBA) Tx. In this longitudinal observational study, a recall of Class II:2 patients who had been treated by a Herbst-MBA during adolescence was conducted. Study models from before and after active Tx, after retention and after recall were assessed using standard occlusal variables and the peer assessment rating index (PAR). These data were compared to historical untreated Class I controls. Twenty out of 33 patients (61%) could be located and participated at age 33.9 ± 2.7 years. When comparing their data to the 13 patients who did not participate, the pre- and post-Tx occlusal findings did not differ systematically; however, the PAR scores of the non-participants were by 3.3-8.2 points higher at all times and the non-participants were 2.1-2.5 years older. Pre-Tx at age 14.4 ± 2.7 years, the participants showed the following mean values: PAR = 15.0 ± 7.0, Class II molar relationship (MR) = 0.8 ± 0.3 cusp widths (cw), overbite = 5.3 ± 1.3 mm. After Tx, a PAR score of 2.9 ± 1.3 and a super Class I MR (-0.1 ± 0.1 cw) with normal overbite (1.2 ± 0.8 mm) existed. At recall, a PAR score increase to 5.9 ± 3.6 points had occurred, mainly caused by an increase of overbite to 2.5 ± 1.5 mm. The average MR remained Class I (0.0 ± 0.2 cw). For all variables, the untreated controls exhibited similar findings. The occlusal outcome of Class II:2 Herbst-MBA Tx exhibited very good long-term stability. While mild post-Tx changes occurred, the long-term findings are similar to untreated Class I controls. © The Author(s) 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  10. The temporal outcomes of open versus arthroscopic knotted and knotless rotator cuff repair over 5 years

    Science.gov (United States)

    Lucena, Thomas R; Lam, Patrick H; Millar, Neal L

    2015-01-01

    Background The present study aimed to determine how repair technique influenced structural and clinical outcomes at 5 years post-surgery. Methods Three cohorts of patients had repair of a symptomatic rotator cuff tear using (i) an open double-row mattress repair technique (n = 25); (ii) arthroscopic single-row simple suture knotted technique (n = 25); or (iii) arthroscopic single-row inverted mattress knotless technique (n = 36) by one surgeon. Standardized patient- and examiner-determined outcomes were obtained pre-operatively and postoperatively with a validated protocol, ultrasound were also performed at the same time. Results Retear occurred more often after open repair (48%) at 5 years than after arthroscopic knotted (33%) and arthroscopic knotless (26%) repair. Retear was associated with increasing age, pre-operative tear size and weaker pre-operative and 5 years postoperative cuff strength. Between 2 years and 5 years, the open repair group experienced an increase in the frequency of pain during activity, as well as in the difficulty experienced and the severity of pain during overhead activities (p repair group. Conclusions At 5-year follow-up, arthroscopic rotator cuff repair techniques resulted in fewer retears and better outcomes compared to an open double-row technique. PMID:27582985

  11. Bleb needling outcomes for failed trabeculectomy blebs in Asian eyes: a 2-year follow up.

    Science.gov (United States)

    Tsai, Andrew S H; Boey, Pui Yi; Htoon, Hla M; Wong, Tina T

    2015-01-01

    To describe the outcomes of bleb needling in primary glaucoma in an Asian tertiary eye centre over a 2y period. To compare the success rates between primary angle-closure glaucoma (PACG) and primary open angle glaucoma (POAG). Lastly, to identify factors associated with success of bleb needling. This was a retrospective review of 227 patients who underwent bleb needling between June 2009 and June 2011 in Singapore National Eye Centre. The 5-fluorouracil (5-FU) augmented bleb needling was performed either at the slit lamp or in the operating theatre. Repeat bleb needlings were performed as necessary. Complete success was defined as maintenance of intraocular pressure (IOP) ≥6 mm Hg and ≤21 mm Hg, in the absence of further surgery or use of antiglaucoma medication. Qualified success met the above criteria with or without use of antiglaucoma medications. One hundred and seventy-five eyes completed the two-year follow up. Sixty-nine percent of participants had POAG and 31% had PACG. The mean interval between filtering surgery and bleb needling was 299.9±616.4d for POAG and 167.1±272.2d for PACG. Mean needling attempts were 1.9±1.4 and 2±1.6 for POAG and PACG respectively. In general, there was a statistically significant reduction of IOP ranging from 21.9% to 26.8% from month 1 through to month 24. The complete success rates at month 6 were 70.0% for POAG and 65.7% for PACG. At month 12, this decreased to 62.2% for POAG and PACG and at month 24, 57.9% for POAG and 63.0% for PACG respectively. The qualified success rates at month 6 for POAG and PACG were 23.8% and 29.9% respectively, 32.2% and 29.2% at month 12, and 34.7% and 29.6% at month 24. The success rates between POAG and PACG were not significantly different (P>0.05 for complete and qualified success at months 6, 12 and 24). An increased number of needlings and higher pre-needling IOP were associated with failure. The 5-FU augmented bleb needling within one year of trabeculectomy in Asian eyes can

  12. Bleb needling outcomes for failed trabeculectomy blebs in Asian eyes:a 2-year follow up

    Directory of Open Access Journals (Sweden)

    Andrew S. H. Tsai

    2015-08-01

    Full Text Available AIM:To describe the outcomes of bleb needling in primary glaucoma in an Asian tertiary eye centre over a 2y period. To compare the success rates between primary angle-closure glaucoma (PACG and primary open angle glaucoma (POAG. Lastly, to identify factors associated with success of bleb needling.METHODS:This was a retrospective review of 227 patients who underwent bleb needling between June 2009 and June 2011 in Singapore National Eye Centre. The 5-fluorouracil (5-FU augmented bleb needling was performed either at the slit lamp or in the operating theatre. Repeat bleb needlings were performed as necessary. Complete success was defined as maintenance of intraocular pressure (IOP ≥6 mm Hg and ≤21 mm Hg, in the absence of further surgery or use of antiglaucoma medication. Qualified success met the above criteria with or without use of antiglaucoma medications.RESULTS:One hundred and seventy-five eyes completed the two-year follow up. Sixty-nine percent of participants had POAG and 31% had PACG. The mean interval between filtering surgery and bleb needling was 299.9±616.4d for POAG and 167.1±272.2d for PACG. Mean needling attempts were 1.9±1.4 and 2±1.6 for POAG and PACG respectively. In general, there was a statistically significant reduction of IOP ranging from 21.9% to 26.8% from month 1 through to month 24. The complete success rates at month 6 were 70.0% for POAG and 65.7% for PACG. At month 12, this decreased to 62.2% for POAG and PACG and at month 24, 57.9% for POAG and 63.0% for PACG respectively. The qualified success rates at month 6 for POAG and PACG were 23.8% and 29.9% respectively, 32.2% and 29.2% at month 12, and 34.7% and 29.6% at month 24. The success rates between POAG and PACG were not significantly different (P>0.05 for complete and qualified success at months 6, 12 and 24. An increased number of needlings and higher pre-needling IOP were associated with failure.CONCLUSION:The5-FU augmented bleb needling within one year

  13. Performance Evaluation of the New Fork-Absorbers of RSG-GAS Control Rod

    International Nuclear Information System (INIS)

    Slamet Wiranto; Purwadi; Arif Hidayat; Agus Sanjaya

    2012-01-01

    During the operation of RSG-GAS reactor, it has been replaced 8 fork-absorber by the new absorber from PT. Batan Teknologi. After almost 5 years under utilization it is important to be evaluated to determine the physical condition and its performance, which is still in good condition and functioning according to the requirements of its operations. The evaluation has been carried out by studying and analyzing the data of the fork-absorber utilization in the the reactor core. The fork absorber data consist of visual inspection, control rod drop time measurement and control rod reactivity and safety margin measurement for each operation cycle. Through the observation up to date with the operating cycle of 79, could be concluded that the fork-absorber condition is still good, and has ability, to support the operation until ± 660 MWD/cycle, which is characterized by obtaining the value of ρ-excess is sufficient for operation, with a large safety margin. (author)

  14. A 5 year prospective study of patient-relevant outcomes after total knee replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A-K; Toksvig-Larsen, S; Roos, E M

    2008-01-01

    men, mean age 71 (51-86) assigned for TKR at the Department of Orthopaedics at Lund University Hospital were included in the study. The self-administered questionnaires Knee injury and Osteoarthritis Outcome Score (KOOS) and SF-36 were mailed preoperatively and 6 months, 12 months and at 5 years......OBJECTIVE: To prospectively describe self-reported outcomes up to 5 years after total knee replacement (TKR) in Osteoarthritis (OA) and to study which patient-relevant factors may predict outcomes for pain and physical function (PF). METHODS: 102 consecutive patients with knee OA, 63 women and 39...... postoperatively. RESULTS: Response rate at 5 years was 86%. At 6 months significant improvement was seen in all KOOS and SF-36 scores (P

  15. Broadband near-infrared metamaterial absorbers utilizing highly lossy metals

    DEFF Research Database (Denmark)

    Ding, Fei; Dai, Jin; Chen, Yiting

    2016-01-01

    Radiation absorbers have increasingly been attracting attention as crucial components for controllable thermal emission, energy harvesting, modulators, etc. However, it is still challenging to realize thin absorbers which can operate over a wide spectrum range. Here, we propose and experimentally...... demonstrate thin, broadband, polarization-insensitive and omnidirectional absorbers working in the near-infrared range. We choose titanium (Ti) instead of the commonly used gold (Au) to construct nano-disk arrays on the top of a silicon dioxide (SiO2) coated Au substrate, with the quality (Q) factor...

  16. Cerebral oxygenation is associated with neurodevelopmental outcome of preterm children at age 2 to 3 years

    NARCIS (Netherlands)

    Verhagen, Elise A.; Van Braeckel, Koenraad N. J. A.; van der Veere, Christa N.; Groen, Henk; Dijk, Peter H.; Hulzebos, Christian V.; Bos, Arend F.

    AIM: The aim of the study was to determine whether regional cerebral tissue oxygen saturation (rc SO2 ) and fractional tissue oxygen extraction (FTOE), using near-infrared spectroscopy, are associated with neurodevelopmental outcome of preterm infants. METHOD: We measured rc SO2 on days 1, 2, 3, 4,

  17. New Technology in Hydrogen Absorbers for Muon Cooling Channels

    CERN Document Server

    Cummings, M A C

    2005-01-01

    Ionization cooling is the only technique fast enough to cool and focus muons for neutrino factories and muon colliders, and hydrogen is the optimal material for maximum cooling and minimal multiple scattering. Liquid hydrogen absorber R&D for the Muon Collaboration has proceeded on parallel and complementary fronts. The continuing LH2 absorber engineering and technical developments by the MuCool group conducted by ICAR* institutions (NIU, IIT and UIUC), the University of Mississippi and Oxford University, in cooperation with Fermilab, will be summarized, including results from the first hydrogen absorber tests at the newly constructed FNAL Mucool Test Area (MTA). The program includes designs for the high-powered test of an absorber prototype (external heat exchange) at the MTA which are nearing completion to be installed by summer 2005, an alternative absorber design (internal heat exchange) being finalized for the approved cooling experiment (MICE) at Rutherford-Appleton Laboratory, and a novel idea for ...

  18. The Development of Two Composite Energy Absorbers for Use in a Transport Rotorcraft Airframe Crash Testbed (TRACT 2) Full-Scale Crash Test

    Science.gov (United States)

    Littell, Justin D.; Jackson, Karen E.; Annett, Martin S.; Seal, Michael D.; Fasanella, Edwin L.

    2015-01-01

    Two composite energy absorbers were developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program. A conical-shaped energy absorber, designated the conusoid, was evaluated that consisted of four layers of hybrid carbon-Kevlar plain weave fabric oriented at [+45deg/-45deg/-45deg/+45deg] with respect to the vertical direction. A sinusoidal-shaped energy absorber, designated the sinusoid, was developed that consisted of hybrid carbon-Kevlar plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical direction, and a closed-cell ELFOAM P200 polyisocyanurate (2.0-lb/cu ft) foam core. The design goal for the energy absorbers was to achieve average floor-level accelerations of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in both designs were assessed through dynamic crush testing of component specimens. Once the designs were finalized, subfloor beams of each configuration were fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorbers prior to retrofit into TRACT 2. The retrofitted airframe was crash tested under combined forward and vertical velocity conditions onto soft soil. Finite element models were developed of all test articles and simulations were performed using LS-DYNA, a commercial nonlinear explicit transient dynamic finite element code. Test-analysis results are presented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading for each evaluation level.

  19. Investigations into alterntive substrate, absorber, and buffer layer processing for Cu(In,Ga)Se{sub 2}-based solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Tuttle, J.R.; Berens, T.A.; Keane, J. [National Renewable Energy Lab., Golden, CO (United States)] [and others

    1996-05-01

    High-performance Cu(In,Ga)Se{sub 2}(CIGS)-based solar cells are presently fabricated within a narrow range of processing options. In this contribution, alternative substrate, absorber, and buffer layer processing is considered. Cell performance varies considerably when alternative substrates are employed. These variations are narrowed with the addition of Na via a Na{sub 2}S compound. Sputtered and electrodeposited CIGS precursors and completed absorbers show promise as alternatives to evaporation. A recrystallization process is required to improve their quality. (In,Ga){sub y}Se buffer layers contribute to cell performance above 10. Further improvements in these alternatives will lead to combined cell performance greater than 10% in the near term.

  20. Triplet-triplet energy transfer from a UV-A absorber butylmethoxydibenzoylmethane to UV-B absorbers.

    Science.gov (United States)

    Kikuchi, Azusa; Oguchi-Fujiyama, Nozomi; Miyazawa, Kazuyuki; Yagi, Mikio

    2014-01-01

    The phosphorescence decay of a UV-A absorber, 4-tert-butyl-4'-methoxydibenzolymethane (BMDBM) has been observed following a 355 nm laser excitation in the absence and presence of UV-B absorbers, 2-ethylhexyl 4-methoxycinnamate (octyl methoxycinnamate, OMC) and octocrylene (OCR) in ethanol at 77 K. The lifetime of the lowest excited triplet (T1) state of BMDBM is significantly reduced in the presence of OMC and OCR. The observed quenching of BMDBM triplet by OMC and OCR suggests that the intermolecular triplet-triplet energy transfer occurs from BMDBM to OMC and OCR. The T1 state of OCR is nonphosphorescent or very weakly phosphorescent. However, we have shown that the energy level of the T1 state of OCR is lower than that of the enol form of BMDBM. Our methodology of energy-donor phosphorescence decay measurements can be applied to the study of the triplet-triplet energy transfer between UV absorbers even if the energy acceptor is nonphosphorescent. In addition, the delayed fluorescence of BMDBM due to triplet-triplet annihilation was observed in the BMDBM-OMC and BMDBM-OCR mixtures in ethanol at 77 K. Delayed fluorescence is one of the deactivation processes of the excited states of BMDBM under our experimental conditions. © 2013 The American Society of Photobiology.

  1. Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic

    Directory of Open Access Journals (Sweden)

    Ehsan Hekmatian

    2016-07-01

    Full Text Available Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side. Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18. The overall results of this study were similar to other studies.

  2. Heat resistance and local structure of FeCl2-absorbed crosslinked poly(γ-glutamic acid)

    International Nuclear Information System (INIS)

    Nishida, T.; Kamezawa, H.; Hara, T.; Matsumoto, Y.

    2001-01-01

    Fiber of Japanese food natto (Bacillus subtilis) is known to be superabsorbent poly(γ-glutamic acid) (PGA). NaCl particles precipitate in FeCl 2 -absorbed crosslinked PGA when heated at crystallization temperature of 320 deg C for 10 to 60 min. After heat treatment the Moessbauer spectrum of FeCl 2 -crosslinked PGA consists of a quadrupole doublet due to FeCl 2 x 2H 2 O. The Moessbauer spectrum of anhydrous FeCl 2 reagent heated under the same condition shows an intense sextet due to α-Fe 2 O 3 . These results prove that the superabsorbent polymer, crosslinked PGA, has higher heat resistance. (author)

  3. The absorbed dose in air of photons generated from secondary cosmic rays at sea level at Nagoya, Japan

    International Nuclear Information System (INIS)

    Akhmad, Y.R.

    1995-01-01

    Investigations have been carried out to determine the absorbed dose in air of photons generated from secondary cosmic radiation at sea level at Nagoya, Japan. To isolate the contribution from cosmic photons, the pulse-height distributions due to μ particles and electrons were eliminated from the observed pulse-height distribution of a measurement with a 3'' diam. spherical NaI(Tl) detector. The pulse height due to μ particles and electrons was inferred from the coincidence technique using two types of scintillation detectors with different sensitivities to photons. To obtain the photon fluence rate for further dose calculation, the pulse-height distribution of cosmic photons was unfolded by the iterative method. The mean and its standard deviation of the absorbed dose in air and fluence rate due to cosmic photons calculated from a one year observation are 2.86±0.05 nGy.h -1 and 0.1342±0.0015 photons.cm -2 .s -1 , respectively. The absorbed dose in air from cosmic photons was 0.5% lower during autumn to winter and 0.6% higher during spring to summer than the mean taken over the year. (author)

  4. Parenting behavior at 2 years predicts school-age performance at 7 years in very preterm children.

    Science.gov (United States)

    Treyvaud, Karli; Doyle, Lex W; Lee, Katherine J; Ure, Alexandra; Inder, Terrie E; Hunt, Rod W; Anderson, Peter J

    2016-07-01

    Parenting influences child development, but it is unclear whether early parenting behavior can influence school-age outcomes in very preterm (VPT) children, and/or if certain groups of VPT children may be more affected by early parenting behavior. These research questions were examined. Participants were 147 children born parent-child interaction was assessed, and at 7 years CA, general intelligence (IQ), language, executive function, academic skills, and social-emotional functioning were assessed. Higher levels of parent-child synchrony, and parent facilitation, sensitivity and positive affect at 2 years were associated with better child outcomes at 7 years, while higher levels of intrusiveness and negative affect were associated with poorer outcomes. Many of these relationships remained after controlling for early child cognitive development. Interactions between child medical risk (higher/lower) and parenting were limited to child reading, math, and executive functioning outcomes, with stronger relationships for lower medical risk children. The contribution of early parenting to VPT children's school-age performance is significant, with stronger effects for lower medical risk children in some outcomes. These findings support the premise that parenting strategies should be included in the NICU and early interventions programs for VPT infants. © 2015 Association for Child and Adolescent Mental Health.

  5. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 2: Data from seat testing

    Science.gov (United States)

    Shane, S. J.

    1985-01-01

    The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.

  6. Solar radiation absorbing material

    Science.gov (United States)

    Googin, John M.; Schmitt, Charles R.; Schreyer, James M.; Whitehead, Harlan D.

    1977-01-01

    Solar energy absorbing means in solar collectors are provided by a solar selective carbon surface. A solar selective carbon surface is a microporous carbon surface having pores within the range of 0.2 to 2 micrometers. Such a surface is provided in a microporous carbon article by controlling the pore size. A thermally conductive substrate is provided with a solar selective surface by adhering an array of carbon particles in a suitable binder to the substrate, a majority of said particles having diameters within the range of about 0.2-10 microns.

  7. Calirimeter/absorber optimization for a RHIC dimuon experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aronson, S.H.; Murtagh, M.J.; Starks, M. [Brookhaven National Lab., Upton, NY (United States); Liu, X.T.; Petitt, G.A.; Zhang, Z. [Georgia State Univ., Atlanta (United States); Ewell, L.A.; Hill, J.C.; Wohn, F.K. [Iowa State Univ., Ames (United States); Costales, J.B.; Namboodiri, M.N., Sangster, T.C.; Thomas, J.H. [Lawrence Livermore National Lab., CA (United States); Gavron, A.; Waters, L. [Los Alamos National Lab., NM (United States); Kehoe, W.L.; Steadman, S.G. [Massachusetts Institute of Technology, Cambridge (United States); Awes, T.C.; Obenshain, F.E.; Saini, S.; Young, G.R. [Oak Ridge National Lab., TN (United States); Chang, J.; Fung, S.Y.; Kang, J.H. [Univ. of California, Riverside, CA (United States); Kreke, J.; He, Xiaochun, Sorensen, S.P. [Univ. of Tennessee, Knoxville (United States); Cornell, E.C.; Maguire, C.F. [Vanderbilt Univ., Nashville, TN (United States)

    1991-12-31

    The RD-10 R&D effort on calorimeter/absorber optimization for a RHIC experiment had an extended run in 1991 using the A2 test beam at the AGS. Measurements were made of the leakage of particles behind various model hadron calorimeters. Behavior of the calorimeter/absorber as a muon-identifier was studied. First comparisons of results from test measurements to calculated results using the GHEISHA code were made

  8. Long-term outcome of patients with dysthymia and panic disorder: a naturalistic 9-year follow-up study.

    Science.gov (United States)

    Svanborg, Cecilia; Wistedt, Anna Aberg; Svanborg, Pär

    2008-01-01

    The highly prevalent psychiatric disorders dysthymia and panic disorder have often a chronic or recurrent course with superimposed major depression. The prominent comorbidity between these diagnoses constitutes a confounding factor in the study of long-term outcome. We performed a 9-year follow-up of 38 patients with "pure" diagnoses, i.e. without comorbid dysthymia and panic disorder, selected from two 2-year naturalistic treatment studies with psychotherapy and antidepressant medication. The aims of the present study were to investigate 1) the stability of change, and 2) the impact of comorbid personality disorders (PDs) on long-term outcome. Patients were reassessed with SCID-I and SCID-II interviews, SCL-90/BSI and a detailed, modified life-charting interview, investigating course and treatment over time. About 50% of patients showed substantial improvement, of whom about half were in remission. Comorbid PD was a negative prognostic factor independently of Axis I diagnosis. Although patients with panic disorder had a lower frequency of comorbid PD, later onset, shorter duration of illness and better outcome after the original studies, there was no difference in the long-term outcome. The less stable outcome among panic patients suggests that standard treatments are not resulting in enduring remission. In order to achieve remission, it is necessary to 1) address comorbid PDs, 2) perform careful assessments of all comorbid diagnoses, and 3) build routines for the follow-up and augmentation of treatments.

  9. Multicenter Analysis of Midterm Clinical Outcomes of Arthroscopic Labral Repair in the Hip: Minimum 5-Year Follow-up.

    Science.gov (United States)

    Hevesi, Mario; Krych, Aaron J; Johnson, Nick R; Redmond, John M; Hartigan, David E; Levy, Bruce A; Domb, Benjamin G

    2018-02-01

    The technique of hip arthroscopic surgery is advancing and becoming more commonly performed. However, most current reported results are limited to short-term follow-up, and therefore, the durability of the procedure is largely unknown. To perform a multicenter analysis of mid-term clinical outcomes of arthroscopic hip labral repair and determine the risk factors for patient outcomes. Cohort study; Level of evidence, 3. Prospectively collected data of primary hip arthroscopic labral repair performed at 4 high-volume centers between 2008 and 2011 were reviewed retrospectively. Patients were assessed preoperatively and postoperatively with the visual analog scale (VAS), modified Harris Hip Score (mHHS), and Hip Outcome Score-Sports-Specific Subscale (HOS-SSS) at a minimum of 5 years' follow-up. Factors including age, body mass index (BMI), Tönnis grade, and cartilage grade were analyzed in relation to outcome scores, and revision rates were determined. Failure was defined as subsequent ipsilateral hip surgery, including revision arthroscopic surgery and open hip surgery. A total of 303 patients (101 male, 202 female) with a mean age of 32.0 years (range, 10.7-58.9 years) were followed for a mean of 5.7 years (range, 5.0-7.9 years). Patients achieved mean improvements in VAS of 3.5 points, mHHS of 20.1 points, and HOS-SSS of 29.3 points. Thirty-seven patients (12.2%) underwent revision arthroscopic surgery, and 12 (4.0%) underwent periacetabular osteotomy, resurfacing, or total hip arthroplasty during the study period. Patients with a BMI >30 kg/m 2 had a mean mHHS score 9.5 points lower and a mean HOS-SSS score 15.9 points lower than those with a BMI ≤30 kg/m 2 ( P 35 years at surgery had a mean mHHS score 4.5 points lower and a HOS-SSS score 6.7 points lower than those aged ≤35 years ( P = .03). Patients with Tönnis grade 2 radiographs demonstrated a 12.5-point worse mHHS score ( P = .02) and a 23.0-point worse HOS-SSS score ( P SSS scores after arthroscopic

  10. Superlattice photonic crystal as broadband solar absorber for high temperature operation.

    Science.gov (United States)

    Rinnerbauer, Veronika; Shen, Yichen; Joannopoulos, John D; Soljačić, Marin; Schäffler, Friedrich; Celanovic, Ivan

    2014-12-15

    A high performance solar absorber using a 2D tantalum superlattice photonic crystal (PhC) is proposed and its design is optimized for high-temperature energy conversion. In contrast to the simple lattice PhC, which is limited by diffraction in the short wavelength range, the superlattice PhC achieves solar absorption over broadband spectral range due to the contribution from two superposed lattices with different cavity radii. The superlattice PhC geometry is tailored to achieve maximum thermal transfer efficiency for a low concentration system of 250 suns at 1500 K reaching 85.0% solar absorptivity. In the high concentration case of 1000 suns, the superlattice PhC absorber achieves a solar absorptivity of 96.2% and a thermal transfer efficiency of 82.9% at 1500 K, amounting to an improvement of 10% and 5%, respectively, versus the simple square lattice PhC absorber. In addition, the performance of the superlattice PhC absorber is studied in a solar thermophotovoltaic system which is optimized to minimize absorber re-emission by reducing the absorber-to-emitter area ratio and using a highly reflective silver aperture.

  11. Long term (7 or more years) outcomes of the sleeve gastrectomy: a meta-analysis.

    Science.gov (United States)

    Clapp, Benjamin; Wynn, Matthew; Martyn, Colin; Foster, Chase; O'Dell, Montana; Tyroch, Alan

    2018-03-06

    The laparoscopic sleeve gastrectomy is now the most common bariatric operation in the United States and has become an established procedure in the armamentarium of the bariatric surgeon. However, this has happened without the strong support of long-term outcomes data, namely the rate of revision and durability of the weight loss. Newly published data from around the world are starting to show alarming trends in these 2 areas. This paper will examine the published and presented data with at least a 7-year follow-up. This is a meta-analysis on published data with at least 7 years of follow-up from the laparoscopic sleeve gastrectomy. Online published articles. We performed a meta-analysis of publications with at least 7 years of follow-up with the keywords "laparoscopic, bariatric, sleeve gastrectomy, sleeve, long-term, long, term, results, follow-up, follow up, conversion, 7 years, 8 years, 9 years, 10 years, 11 years." We queried the PubMed, MEDLINE, and ClinicalKey search engines, which included abstracts as well. The I 2 statistic was used to determine the heterogeneity across the studies. In presence of heterogeneity, a random effect model using the Dersimonian and Laird method was used to estimate the pooled estimates. The results were summarized using effect size along with a 95% confidence interval (CI). Meta-regression was also used to assess the effect of body mass index and follow-up years on the incidence of recidivism at ≥7 years. Nine cohort studies met the inclusion criteria, with a total of 2280 patients included initially. Only 652 patients had completed ≥7 years of follow-up. At ≥7 years, the long-term weight recidivism rate was estimated to be 27.8% (I 2 = .60%; 95% CI: 22.8%-32.7%) with a range of 14% to 37%. The overall revision rate was estimated to be 19.9% (I 2 = 93.8%; 95% CI: 11.3%-28.5%). This was broken down into 13.1% (I 2 = 93.8%; 95% CI: 5.6%-20.6%) due to weight regain (5 studies) and 2.9% (I 2 = 60.8%; 95% CI: 1%-4.9%) due to

  12. Intermediate Term (3-6 Years Post Surgery) Outcome of ...

    African Journals Online (AJOL)

    Post-operatively, the 5 eyes had VA ranging from 6/60 to NLP, after a variable follow-up period of 3-6 years. Complications included development of tough vascularized retroprosthetic membrane (4 eyes) and infective endophthalmitis in one eye. Conclusion: The intermediate-term outcome of keratoprosthesis surgery in ...

  13. A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

    Directory of Open Access Journals (Sweden)

    Kathy Willowson

    2018-06-01

    Full Text Available Objective(s: To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate for treatment of neuroendocrine tumours (NETs. Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after injection. Planar data were corrected for attenuation using transmission data, and were converted to units of absolute activity via two methods, using either a calibration standard in the field of view or relative to pre-voiding image total counts. Hand drawn regions of interest were used to generate time activity curves and kidney absorbed dose estimates in OLINDA-EXM. Fully quantitative SPECT data were generated using CT-derived corrections for both scatter and attenuation, before correction for dead time and application of a camera specific sensitivity factor to convert data to units of absolute activity. Volumes of interest were defined for kidney using the co-registered x-ray CT, before time activity curves and absorbed dose measures were generated in OLINDA-EXM, both with and without corrections made to the model for patient specific kidney volumes. Quantitative SPECT data were also used to derive dose maps through dose kernel convolution (DKC, which was treated as the gold standard. Results: A total of 50 studies were analysed, corresponding to various cycles of treatment from 21 patients. Planar absorbed dose estimates were consistently higher than SPECT derived estimates by, on average, a factor of 3. Conclusion: Quantitative SPECT is considered the gold standard approach for organ specific dosimetry however often relies on in house software. As such planar methods for estimating absorbed dose are much more widely available, and in particular, are often the only source of reference in previously published data. For the case of Lutate dosimetry, planar

  14. Comparative technical-economical analysis of solar systems with liquid absorbent

    International Nuclear Information System (INIS)

    Kaloyanov, N.; Popova, I.

    2005-01-01

    An analyses of solar water heating systems with two types liquid absorbent is presented. A system with classic collector design is used for comparison. The dependence between the value of the collectors active area and the absorbent type, collectors slope and design parameters is discussed. Two economic indexes (payback period and index of actual net value, based on the electricity price) are used for comparison of the different variants of the system. The presented results shown that: 1) the payback period can be reduced twice if the collectors with liquid absorbent are used; 2) the index of actual net value of the systems using the collectors with fluid absorbent is about four times higher than this one with classic collectors; 3) the systems using distilled water like a liquid absorbent can not fulfil the requirements for the positive economic indicators

  15. Clinical presentation and outcome of riboflavin transporter deficiency: mini review after five years of experience

    NARCIS (Netherlands)

    Jaeger, Bregje; Bosch, Annet M.

    2016-01-01

    Riboflavin (vitamin B2) is absorbed in the small intestine by the human riboflavin transporters RFVT1 and RFVT3. A third riboflavin transporter (RFVT2) is expressed in the brain. In 2010 it was demonstrated that mutations in the riboflavin transporter genes SLC52A2 (coding for RFVT2) and SLC52A3

  16. Outcome at 2 Years after Dextrose Gel Treatment for Neonatal Hypoglycemia: Follow-Up of a Randomized Trial.

    Science.gov (United States)

    Harris, Deborah L; Alsweiler, Jane M; Ansell, Judith M; Gamble, Gregory D; Thompson, Benjamin; Wouldes, Trecia A; Yu, Tzu-Ying; Harding, Jane E

    2016-03-01

    To determine neurodevelopmental outcome at 2 years' corrected age in children randomized to treatment with dextrose gel or placebo for hypoglycemia soon after birth (The Sugar Babies Study). This was a follow-up study of 184 children with hypoglycemia (dextrose (90/118, 76%) or placebo gel (94/119, 79%). Assessments were performed at Kahikatea House, Hamilton, New Zealand, and included neurologic function and general health (pediatrician assessed), cognitive, language, behavior, and motor skills (Bayley Scales of Infant and Toddler Development, Third Edition), executive function (clinical assessment and Behaviour Rating Inventory of Executive Function-Preschool Edition), and vision (clinical examination and global motion perception). Coprimary outcomes were neurosensory impairment (cognitive, language or motor score below -1 SD or cerebral palsy or blind or deaf) and processing difficulty (executive function or global motion perception worse than 1.5 SD from the mean). Statistical tests were two sided with 5% significance level. Mean (± SD) birth weight was 3093 ± 803 g and mean gestation was 37.7 ± 1.6 weeks. Sixty-six children (36%) had neurosensory impairment (1 severe, 6 moderate, 59 mild) with similar rates in both groups (dextrose 38% vs placebo 34%, relative risk 1.11, 95% CI 0.75-1.63). Processing difficulty also was similar between groups (dextrose 10% vs placebo 18%, relative risk 0.52, 95% CI 0.23-1.15). Dextrose gel is safe for the treatment of neonatal hypoglycemia, but neurosensory impairment is common among these children. Australian New Zealand Clinical Trials Registry: ACTRN 12608000623392. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Socioeconomic Status and Poor Health Outcome at 10 Years of Follow-Up in the Multi-Ethnic Study of Atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Steven Shea

    Full Text Available Predictors of healthy aging have not been well-studied using longitudinal data with demographic, clinical, subclinical, and genetic information. The objective was to identify predictors of poor health outcome at 10 years of follow-up in the Multi-Ethnic Study of Atherosclerosis (MESA.Prospective cohort study.Population-based sample from 6 U.S. communities.4,355 participants In the MESA Study.Poor health outcome at 10 years of follow-up was defined as having died or having clinical cardiovascular disease, depression, cognitive impairment, chronic obstructive pulmonary disease, or cancer other than non-melanoma skin cancer. Absolute risk regression was used to estimate risk differences in the outcome adjusting for demographic variables, clinical and behavioral risk factors, subclinical cardiovascular disease, and ApoE genotype. Models were weighted to account for selective attrition.Mean age at 10 years of follow-up was 69.5 years; 1,480 participants had a poor health outcome, 2,157 participants were in good health, and 718 were unknown. Older age, smoking, not taking a statin, hypertension, diabetes, and higher coronary calcium score were associated with higher probability of poor health outcome. After multivariable adjustment, participants in the lowest income and educational categories had 7 to 14% greater absolute risk of poor health outcome at 10 years of follow-up compared to those in the next highest categories of income or education (P = 0.002 for both. Those in the lowest categories of both income and education had 21% greater absolute risk of poor health outcome compared to those in the highest categories of both income and education.Low income and educational level predict poor health outcome at 10 years of follow-up in an aging cohort, independent of clinical and behavioral risk factors and subclinical cardiovascular disease.

  18. Foliage nitrogen turnover: differences among nitrogen absorbed at different times by Quercus serrata saplings

    Science.gov (United States)

    Ueda, Miki U.; Mizumachi, Eri; Tokuchi, Naoko

    2011-01-01

    Background and Aims Nitrogen turnover within plants has been intensively studied to better understand nitrogen use strategies. However, differences among the nitrogen absorbed at different times are not completely understood and the fate of nitrogen absorbed during winter is largely uncharacterized. In the present study, nitrogen absorbed at different times of the year (growing season, winter and previous growing season) was traced, and the within-leaf nitrogen turnover of a temperate deciduous oak Quercus serrata was investigated. Methods The contributions of nitrogen absorbed at the three different times to leaf construction, translocation during the growing season, and the leaf-level resorption efficiency during leaf senescence were compared using 15N. Key Results Winter- and previous growing season-absorbed nitrogen significantly contributed to leaf construction, although the contribution was smaller than that of growing season-absorbed nitrogen. On the other hand, the leaf-level resorption efficiency of winter- and previous growing season-absorbed nitrogen was higher than that of growing season-absorbed nitrogen, suggesting that older nitrogen is better retained in leaves than recently absorbed nitrogen. Conclusions The results demonstrate that nitrogen turnover in leaves varies with nitrogen absorption times. These findings are important for understanding plant nitrogen use strategies and nitrogen cycles in forest ecosystems. PMID:21515608

  19. Filtration: Novel Absorber Evaluation Club aims at standardized testing

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the past few years a number of novel absorber materials, both organic and inorganic, have appeared on the market - some claiming to achieve very large decontamination factors for metal ions, including those having radioactive isotopes. Several of these materials have been tested by individual companies in the nuclear industry and some have shown promise as decontaminants for radioactive waste streams. Unfortunately, the results obtained for the treatment of a particular waste stream cannot be applied directly to the many and diverse waste streams generated throughout the nuclear industry. A unified and standardized testing programme making use of available expertise is necessary to provide a fair and meaningful comparison. In November 1988, representatives of the United Kingdom nuclear industry agreed to form the Novel Absorber Evaluation Club to assess absorber materials and to undertake the necessary work to identify the extent and rate of adsorption of radionuclides by such materials from a set of typical reference waste streams. (author)

  20. Neutron absorbers and methods of forming at least a portion of a neutron absorber

    Energy Technology Data Exchange (ETDEWEB)

    Guillen, Donna P; Porter, Douglas L; Swank, W David; Erickson, Arnold W

    2014-12-02

    Methods of forming at least a portion of a neutron absorber include combining a first material and a second material to form a compound, reducing the compound into a plurality of particles, mixing the plurality of particles with a third material, and pressing the mixture of the plurality of particles and the third material. One or more components of neutron absorbers may be formed by such methods. Neutron absorbers may include a composite material including an intermetallic compound comprising hafnium aluminide and a matrix material comprising pure aluminum.

  1. Fabrication of Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe) absorber films based on solid-phase synthesis and blade coating processes

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ruixin, E-mail: mrx_601@126.com [School of Metallurgy and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Beijing Key Laboratory of Special Melting and Preparation of High-end Metal Materials, Beijing 100083 (China); Yang, Fan; Li, Shina; Zhang, Xiaoyong; Li, Xiang; Cheng, Shiyao; Liu, Zilin [School of Metallurgy and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2016-04-15

    Graphical abstract: - Highlights: • Pure CZTS nano-crystalline have been prepared based on solid-phase synthesis. • A simple and modified doctor blade process followed by a selenization technique was utilized to fabricate CZTSSe absorber films. • Comparative studies on the properties of CZTS and CZTSSe absorber films have been investigated. • The band gap of CZTSSe absorber films was determined to be 1.26 eV. - Abstract: CZTSSe is an important earth abundant collection of materials for the development of low cost and high efficiency thin film solar cells. This work developed a simple non-vacuum-based route to fabricate CZTSSe absorber films. This was demonstrated by first synthesizing Cu{sub 2}ZnSnS{sub 4} (CZTS) nano-crystalline based on solid-phase synthesis. Then a stable colloidal ink composed of CZTS nano-crystalline was blade coated on Mo-coated substrates followed by an annealing process under Ar atmosphere. After CZTS films formation, the films were sintered into CZTSSe absorber films by exposing them under Selenium vapor. The formation of a kesterite type CZTS was confirmed using X-ray diffraction and Raman scattering measurements. The band gap of CZTSSe absorber films was determined to be 1.26 eV, which was appropriate for use as an absorber layer in thin film solar cells. The CZTSSe absorber films showed a good photovoltatic performance, demonstrating this simple approach had great potential for CZTSSe solar cell production.

  2. Four years of North American registry home parenteral nutrition outcome data and their implications for patient management

    International Nuclear Information System (INIS)

    Howard, L.; Heaphey, L.; Fleming, C.R.; Lininger, L.; Steiger, E.

    1991-01-01

    The OASIS Registry started annual collection of longitudinal data on patients on home parenteral nutrition (HPN) in 1984. This report describes outcome profiles on 1594 HPN patients in seven disease categories. Analysis showed clinical outcome was principally a reflection of the underlying diagnosis. Patients with Crohn's disease, ischemic bowel disease, motility disorders, radiation enteritis, and congenital bowel dysfunction all had a fairly long-term clinical outcome, whereas those with active cancer and acquired immunodeficiency syndrome (AIDS) had a short-term outcome. The long-term group had a 3-year survival rate of 65 to 80%, they averaged 2.6 complications requiring hospitalization per year, and 49% experienced complete rehabilitation. The short-term group had a mean survival of 6 months; they averaged 4.6 complications per year and about 15% experienced complete rehabilitation. The registry data also indicated HPN was used for 19,700 patients in 1987 with therapy growth averaging about 8% per year. This growth was chiefly from new cancer patients. The number of new patients with long-term disorders in whom HPN was initiated appeared rather constant. The authors conclude that these clinical outcome assessments justify HPN for long-term patients, but the utility and appropriateness of HPN for the cancer and AIDS patients remains uncertain and requires further study. Medical, social, and fiscal aspects of HPN management in long-term and short-term patients appear to involve quite separate considerations

  3. Preoperative psychosocial risk factors for poor outcomes at 1 and 5 years after total knee replacement.

    Science.gov (United States)

    Wylde, Vikki; Trela-Larsen, Lea; Whitehouse, Michael R; Blom, Ashley W

    2017-10-01

    Background and purpose - Psychosocial factors are important risk factors for poor outcomes in the first year after total knee replacement (TKR), however their impact on long-term outcomes is unclear. We aimed to identify preoperative psychosocial risk factors for poor outcomes at 1 year and 5 years after TKR. Patients and methods - 266 patients were recruited prior to TKR surgery. Knee pain and function were assessed preoperatively and at 1 and 5 years postoperative using the WOMAC Pain score, WOMAC Function score and American Knee Society Score (AKSS) Knee score. Preoperative depression, anxiety, catastrophizing, pain self-efficacy and social support were assessed. Statistical analyses involved multiple linear regression and mixed effect linear regression. Results - Higher anxiety was a risk factor for worse pain at 1 year postoperative. No psychosocial factors were associated with any outcomes at 5 years postoperative. Analysis of change over time found that patients with higher pain self-efficacy had lower preoperative pain and experienced less improvement in pain up to 1 year postoperative. Higher pain self-efficacy was associated with less improvement in the AKSS up to 1 year postoperative but more improvement between 1 and 5 years postoperative. Interpretation - Preoperative anxiety was found to influence pain at 1 year after TKR. However, none of the psychosocial variables were risk factors for a poor outcome at 5 years post-operative, suggesting that the negative effects of anxiety on outcome do not persist in the longer-term.

  4. Bench Scale Process for Low Cost CO2 Capture Using a Phase-Changing Absorbent: Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Westendorf, Tiffany [GE Global Research, Niskayuna, New York (United States); Buddle, Stanlee [GE Global Research, Niskayuna, New York (United States); Caraher, Joel [GE Global Research, Niskayuna, New York (United States); Chen, Wei [GE Global Research, Niskayuna, New York (United States); Doherty, Mark [GE Global Research, Niskayuna, New York (United States); Farnum, Rachel [GE Global Research, Niskayuna, New York (United States); Giammattei, Mark [GE Global Research, Niskayuna, New York (United States); Hancu, Dan [GE Global Research, Niskayuna, New York (United States); Miebach, Barbara [GE Global Research, Niskayuna, New York (United States); Perry, Robert [GE Global Research, Niskayuna, New York (United States); Rubinsztajn, Gosia; Spiry, Irina; Wilson, Paul; Wood, Benjamin

    2017-05-31

    The objective of this project is to design and build a bench-scale process for a novel phase-changing aminosilicone-based CO2-capture solvent. The project will establish scalability and technical and economic feasibility of using a phase-changing CO2-capture absorbent for post-combustion capture of CO2 from coal-fired power plants. The U.S. Department of Energy’s goal for Transformational Carbon Capture Technologies is the development of technologies available for demonstration by 2025 that can capture 90% of emitted CO2 with at least 95% CO2 purity for less than $40/tonne of CO2 captured. In the first budget period of the project, the bench-scale phase-changing CO2 capture process was designed using data and operating experience generated under a previous project (ARPA-e project DE-AR0000084). Sizing and specification of all major unit operations was completed, including detailed process and instrumentation diagrams. The system was designed to operate over a wide range of operating conditions to allow for exploration of the effect of process variables on CO2 capture performance. In the second budget period of the project, individual bench-scale unit operations were tested to determine the performance of each of each unit. Solids production was demonstrated in dry simulated flue gas across a wide range of absorber operating conditions, with single stage CO2 conversion rates up to 75mol%. Desorber operation was demonstrated in batch mode, resulting in desorption performance consistent with the equilibrium isotherms for GAP-0/CO2 reaction. Important risks associated with gas humidity impact on solids consistency and desorber temperature impact on thermal degradation were explored, and adjustments to the bench-scale process were made to address those effects. Corrosion experiments were conducted to support selection of suitable materials of construction for the major

  5. Seeking new growth hotspots in absorbing foreign direct investment

    Institute of Scientific and Technical Information of China (English)

    裴长洪

    2009-01-01

    In recent years, China’s service industries have absorbed an increasing amount of foreign direct investment (FDI); foreign investors have taken wholly foreign-owned enterprise (WFOE) as the most preferred vehicle of making investment in China; free ports have become a major source of FDI inflows to China; China’s FDI inflows as a percentage of global FDI inflows have been in decline. In the export-oriented or import-substitution manufacturing industries, China still needs to vigorously absorb FDI in the future. In addition, China should continue opening its infrastructure and social service industries. It is therefore imperative to further improve the institutional and policy environment for foreign investment utilization.

  6. Mechanical shock absorber

    International Nuclear Information System (INIS)

    Vrillon, Bernard.

    1973-01-01

    The mechanical shock absorber described is made of a constant thickness plate pierced with circular holes regularly distributed in such a manner that for all the directions along which the strain is applied during the shock, the same section of the substance forming the plate is achieved. The shock absorber is made in a metal standing up to extensive deformation before breaking, selected from a group comprising mild steels and austenitic stainless steels. This apparatus is used for handling pots of fast neutron reactor fuel elements [fr

  7. Treatment Outcomes in the Ahmed Baerveldt Comparison Study after One Year of Follow-up

    Science.gov (United States)

    Budenz, Donald L; Barton, Keith; Feuer, William J; Schiffman, Joyce; Costa, Vital P.; Godfrey, David G.; Buys, Yvonne

    2010-01-01

    Purpose To determine the relative efficacy and complications of the Ahmed FP7 Glaucoma Valve (AGV) and the Baerveldt 101–350 Glaucoma Implant (BGI) in refractory glaucoma. Design Multicenter randomized controlled clinical trial. Participants 276 patients, including 143 in the AGV group and 133 in the BGI group. Methods Patients aged 18–85 years with refractory glaucoma with intraocular pressure (IOP) greater than or equal to 18 mm Hg in whom an aqueous shunt was planned were randomized to undergo implantation of either an AGV or a BGI. Main Outcome Measures Primary outcome was failure, defined as IOP > 21 mm Hg or not reduced by 20%, IOP ≤ 5 mm Hg, reoperation for glaucoma or removal of implant, or loss of light perception vision. Secondary outcomes included mean IOP, visual acuity, use of supplemental medical therapy, and complications. Results Preoperative IOP (mean ± standard deviation, SD) was 31.2 ± 11.2 in the AGV group and 31.8 ± 12.5 in the BGI group (p = 0.71). At 1 year, IOP was 15.4 ± 5.5 mm Hg in the AGV group and 13.2 ± 6.8 mm Hg in the BGI group (p = 0.007). The number of glaucoma medications (mean ± SD) was 1.8 ± 1.3 in the AGV group and 1.5 ± 1.4 in the BGI group (p = 0.071). The cumulative probability of failure was 16.4% (standard error, SE = 3.1%) in the AGV group and 14.0% (SE = 3.1%) in the BGI group at 1 year (p = 0.52). More patients experienced early postoperative complications in the BGI group (n = 77, 58%) compared to the AGV group (n = 61, 43%, p = 0.016). Serious postoperative complications associated with reoperation and/or vision loss of ≥ 2 Snellen lines occurred in 29 patients (20%) in the AGV group and 45 patients (34%) in the BGI group (p = 0.014). Conclusions Although the average IOP after one year was slightly higher in patients who received an AGV, there were fewer early and serious postoperative complications associated with the use of the AGV than the BGI. PMID:20932583

  8. Five-year outcomes of percutaneous versus surgical coronary revascularization in patients with diabetes mellitus (from the CREDO-Kyoto PCI/CABG Registry Cohort-2).

    Science.gov (United States)

    Marui, Akira; Kimura, Takeshi; Nishiwaki, Noboru; Mitsudo, Kazuaki; Komiya, Tatsuhiko; Hanyu, Michiya; Shiomi, Hiroki; Tanaka, Shiro; Sakata, Ryuzo

    2015-04-15

    We investigated the impact of diabetes mellitus on long-term outcomes of percutaneous coronary intervention (PCI) in the drug-eluting stent era versus coronary artery bypass grafting (CABG) in a real-world population with advanced coronary disease. We identified 3,982 patients with 3-vessel and/or left main disease of 15,939 patients with first coronary revascularization enrolled in the Coronary Revascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2 (patients without diabetes: n = 1,984 [PCI: n = 1,123 and CABG: n = 861], and patients with diabetes: n = 1,998 [PCI: n = 1,065 and CABG: n = 933]). Cumulative 5-year incidence of all-cause death after PCI was significantly higher than after CABG both in patients without and with diabetes (19.8% vs 16.2%, p = 0.01, and 22.9% vs 19.0%, p = 0.046, respectively). After adjusting confounders, the excess mortality risk of PCI relative to CABG was no longer significant (hazard ratio [HR] 1.16; 95% confidence interval [CI] 0.88 to 1.54; p = 0.29) in patients without diabetes, whereas it remained significant (HR 1.31; 95% CI 1.01 to 1.70; p = 0.04) in patients with diabetes. The excess adjusted risks of PCI relative to CABG for cardiac death, myocardial infarction (MI), and any coronary revascularization were significant in both patients without (HR 1.59, 95% CI 1.01 to 2.51, p = 0.047; HR 2.16, 95% CI 1.20 to 3.87, p = 0.01; and HR 3.30, 95% CI 2.55 to 4.25, p PCI relative to CABG for all-cause death, cardiac death, MI, and any revascularization. In conclusion, in both patients without and with diabetes with 3-vessel and/or left main disease, CABG compared with PCI was associated with better 5-year outcomes in terms of cardiac death, MI, and any coronary revascularization. There was no difference in the direction and magnitude of treatment effect of CABG relative to PCI regardless of diabetic status. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. (C6H13N)2BiI5: A One-Dimensional Lead-Free Perovskite-Derivative Photoconductive Light Absorber.

    Science.gov (United States)

    Zhang, Weichuan; Tao, Kewen; Ji, Chengmin; Sun, Zhihua; Han, Shiguo; Zhang, Jing; Wu, Zhenyue; Luo, Junhua

    2018-04-16

    Lead-free organic-inorganic hybrid perovskites have recently attracted intense interest as environmentally friendly, low-cost, chemically stable light absorbers. Here, we reported a new one-dimensional (1D) zigzag chainlike light-absorbing hybrid material of (C 6 H 13 N) 2 BiI 5 , in which the corner-sharing octahedral bismuth halide chains are surrounded by organic cations of tetramethylpiperidinium. This unique zigzag 1D hybrid perovskite-derivative material shows a narrow direct band gap of 2.02 eV and long-lived photoluminescence, which is encouraging for optoelectronic applications. Importantly, it behaves as a typical semiconducting material and displays obvious photoresponse in the visible-light range. This work opens a potential pathway for the further application of 1D lead-free hybrids.

  10. Schoolgirls' experience and appraisal of menstrual absorbents in rural Uganda: a cross-sectional evaluation of reusable sanitary pads.

    Science.gov (United States)

    Hennegan, Julie; Dolan, Catherine; Wu, Maryalice; Scott, Linda; Montgomery, Paul

    2016-12-07

    Governments, multinational organisations, and charities have commenced the distribution of sanitary products to address current deficits in girls' menstrual management. The few effectiveness studies conducted have focused on health and education outcomes but have failed to provide quantitative assessment of girls' preferences, experiences of absorbents, and comfort. Objectives of the study were, first, to quantitatively describe girls' experiences with, and ratings of reliability and acceptability of different menstrual absorbents. Second, to compare ratings of freely-provided reusable pads (AFRIpads) to other existing methods of menstrual management. Finally, to assess differences in self-reported freedom of activity during menses according to menstrual absorbent. Cross-sectional, secondary analysis of data from the final survey of a controlled trial of reusable sanitary padand puberty education provision was undertaken. Participants were 205 menstruating schoolgirls from eight schools in rural Uganda. 72 girls who reported using the intervention-provided reusable pads were compared to those using existing improvised methods (predominately new or old cloth). Schoolgirls using reusable pads provided significantly higher ratings of perceived absorbent reliability across activities, less difficulties changing absorbents, and less disgust with cleaning absorbents. There were no significant differences in reports of outside garment soiling (OR 1.00 95%CI 0.51-1.99), or odour (0.84 95%CI 0.40-1.74) during the last menstrual period. When girls were asked if menstruation caused them to miss daily activities there were no differences between those using reusable pads and those using other existing methods. However, when asked about activities avoided during menstruation, those using reusable pads participated less in physical sports, working in the field, fetching water, and cooking. Reusable pads were rated favourably. This translated into some benefits for self

  11. Intermixing at the heterointerface between ZnS /Zn(S,O) bilayer buffer and CuInS2 thin film solar cell absorber

    Science.gov (United States)

    Bär, M.; Ennaoui, A.; Klaer, J.; Kropp, T.; Sáez-Araoz, R.; Lehmann, S.; Grimm, A.; Lauermann, I.; Loreck, Ch.; Sokoll, St.; Schock, H.-W.; Fischer, Ch.-H.; Lux-Steiner, M. C.; Jung, Ch.

    2006-09-01

    The application of Zn compounds as buffer layers was recently extended to wide-gap CuInS2 (CIS) based thin-film solar cells. Using an alternative chemical deposition route for the buffer preparation aiming at the deposition of a single-layer, nominal ZnS buffer without the need for any toxic reactants such as hydrazine has helped us to achieve a similar efficiency as respective CdS-buffered reference devices. After identifying the deposited Zn compound, as ZnS /Zn(S,O) bilayer buffer in former investigations [M. Bär et al., J. Appl. Phys. 99, 123503 (2006)], this time the focus lies on potential diffusion/intermixing processes at the buffer/absorber interface possibly, clarifying the effect of the heat treatment, which drastically enhances the device performance of respective final solar cells. The interface formation was investigated by x-ray photoelectron and x-ray excited Auger electron spectroscopy. In addition, photoelectron spectroscopy (PES) measurements were also conducted using tunable monochromatized synchrotron radiation in order to gain depth-resolved information. The buffer side of the buffer/absorber heterointerface was investigated by means of the characterization of Zn(S ,O)/ZnS/CIS structures where the ZnS /Zn(S,O) bilayer buffer was deposited successively by different deposition times. In order to make the (in terms of PES information depth) deeply buried absorber side of the buffer/absorber heterointerface accessible for characterization, in these cases the buffer layer was etched away by dilute HClaq. We found indications that while (out-leached) Cu from the absorber layer forms together with the educts in the chemical bath a [Zn(1-Z ),Cu2Z]S-like interlayer between buffer and absorber, Zn is incorporated in the uppermost region of the absorber. Both effects are strongly enhanced by postannealing the Zn(S ,O)/ZnS/CIS samples. However, it was determined that the major fraction of the Cu and Zn can be found quite close to the heterointerface in

  12. [Neurodevelopmental outcome at 3 years of age of infants born at less than 26 weeks].

    Science.gov (United States)

    Delmas, O; Garcia, P; Bernard, V; Fabre, M; Vialet, R; Boubred, F; Fayol, L

    2016-09-01

    To describe the neurodevelopmental outcome and perinatal factors associated with favorable outcome among extremely preterm children at 3 years of age. All infants born before 26 weeks of gestation between 2007 and 2011, admitted to intensive care units participating in a French regional network (western PACA-southern Corsica) were included. Perinatal data were collected to assess the main neonatal morbidities. At 3 years of age, the children's neurodevelopment was assessed by trained physicians participating in the follow-up network. Children were classified according to their disability: none, moderate, or severe. Using logistic regression, we determined the perinatal factors associated with the absence of disability at 3 years of age. One hundred and sixty-two very preterm newborns were admitted to neonatal intensive care units. At discharge the survival rate was 62% (101). Rates of survival increased with gestational age (33% at 23 weeks, 57% at 24 weeks and 68% at 25 weeks). Among the 101 surviving extremely preterm children, 66 were evaluated at 3 years. The perinatal characteristics were not significantly different from those of the children lost to follow-up. Overall, 56% of extremely preterm children had no disability and 6% had severe disability. Cerebral palsy was diagnosed in 13% of children. At 3 years of age, the main perinatal factors associated with no disability were short duration of mechanical ventilation (OR=0.96 [0.93-0.99]; P=0.03) and complete course of prenatal corticosteroids (OR=4.7 [1.2-17.7]; P=0.02). As mortality rates continue to decrease for very preterm infants, concerns are rising about their long-term outcome. In this high-risk population, improving perinatal care remains a challenge to improve long-term outcome. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Absorbed dose optimization in the microplanar beam radiotherapy

    International Nuclear Information System (INIS)

    Company, F.Z.; Jaric, J.; Allen, B.J.

    1996-01-01

    Full text: Recent advances in synchrotron generated X-ray beams with high fluence rate, small divergence and sharply defined microbeam margins permit investigation of the application of an array of closely spaced, parallel or converging microbeams for radiotherapy. The proposed technique takes advantage of the repair mechanism hypothesis of capillary endothelial cells between alternate microbeam zones, which regenerates the lethally irradiated capillaries. Unlike a pencil beam, more accurate dose calculation, beam width and spacing are essential to minimise radiation damage to normal tissue cells outside the target. The absorbed dose between microbeam zones should be kept below the threshold for irreversible radiation damage. Thus the peak-to-valley ratio for the dose distribution should be optimized. The absorbed dose profile depends on the energy of the incident beam and the composition and density of the medium. Using Monte Carlo computations, the radial absorbed dose of single 24 x 24 μm 2 cross-section X-ray beams of different energies in a tissue/lung/tissue phantom was investigated. The results indicated that at 100 keV, closely spaced square cross-sectional microbeams can be applied to the lung. A bundle of parallel 24 μm-wide planar microbeams spaced at 200 μm intervals provides much more irradiation coverage of tissue than is provided by a bundle of parallel, square cross-sectional microbeam, although the former is associated with much smaller Peak (maximum absorbed dose on the beam axis) -to-Valley ( minimum interbeam absorbed dose ) ratios than the latter. In this study the lateral and depth dose of single and multiple microplanar beams with beam dimensions of width 24 μm and 48 μm and height 2-20 cm with energy of 100 keV in a tissue/lung/tissue phantom are investigated. The EGS4 Monte Carlo code is used to calculate dose profiles at different depths and bundles of beams (2 x 2 cm 2 to 20 x 20 cm 2 square cross section) with a 150 μm 200 μm and

  14. An efficient absorbing system for spectrophotometric determination of nitrogen dioxide

    Science.gov (United States)

    Kaveeshwar, Rachana; Amlathe, Sulbha; Gupta, V. K.

    A simple and sensitive spectrophotometric method for determination of atmospheric nitrogen dioxide using o-nitroaniline as an efficient absorbing, as well as diazotizing, reagent is described. o-Nitroaniline present in the absorbing medium is diazotized by the absorbed nitrite ion to form diazonium compound. This is later coupled with 1-amino-2-naphthalene sulphonic acid (ANSA) in acidic medium to give red-violet-coloured dye,having λmax = 545 nm. The isoamyl extract of the red azo dye has λmax = 530 nm. The proposed reagents has ≈ 100% collection efficiency and the stoichiometric ratio of NO 2:NO 2- is 0.74. The other important analytical parameters have been investigated. By employing solvent extraction the sensitivity of the reaction was increased and up to 0.03 mg m -3 nitrogen dioxide could be estimated.

  15. Effects Influencing Plutonium-Absorber Interactions and Distributions in Routine and Upset Waste Treatment Plant Operations

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    This report is the third in a series of analyses written in support of a plan to revise the Hanford Waste Treatment and Immobilization Plant (WTP) Preliminary Criticality Safety Evaluation Report (CSER) that is being implemented at the request of the U.S. Department of Energy (DOE) Criticality Safety Group. A report on the chemical disposition of plutonium in Hanford tank wastes was prepared as Phase 1 of this plan (Delegard and Jones 2015). Phase 2 is the provision of a chemistry report to describe the potential impacts on criticality safety of waste processing operations within the WTP (Freer 2014). In accordance with the request from the Environmental and Nuclear Safety Department of the WTP (Miles and Losey 2012), the Phase 2 report assessed the potential for WTP process conditions within and outside the range of normal control parameters to change the ratio of fissile material to neutron-absorbing material in the waste as it is processed with an eye towards potential implications for criticality safety. The Phase 2 study also considered the implications should WTP processes take place within the credible range of chemistry upset conditions. In the present Phase 3 report, the 28 phenomena described in the Phase 2 report were considered with respect to the disposition of plutonium and various absorber elements. The phenomena identified in the Phase 2 report are evaluated in light of the Phase 1 report and other resources to determine the impacts these phenomena might have to alter the plutonium/absorber dispositions and ratios. The outcomes of the Phase 3 evaluations then can be used to inform subsequent engineering decisions and provide reasonable paths forward to mitigate or overcome real or potential criticality concern in plant operations.

  16. Non-Toxic Buffer Layers in Flexible Cu(In,GaSe2 Photovoltaic Cell Applications with Optimized Absorber Thickness

    Directory of Open Access Journals (Sweden)

    Md. Asaduzzaman

    2017-01-01

    Full Text Available Absorber layer thickness gradient in Cu(In1−xGaxSe2 (CIGS based solar cells and several substitutes for typical cadmium sulfide (CdS buffer layers, such as ZnS, ZnO, ZnS(O,OH, Zn1−xSnxOy (ZTO, ZnSe, and In2S3, have been analyzed by a device emulation program and tool (ADEPT 2.1 to determine optimum efficiency. As a reference type, the CIGS cell with CdS buffer provides a theoretical efficiency of 23.23% when the optimum absorber layer thickness was determined as 1.6 μm. It is also observed that this highly efficient CIGS cell would have an absorber layer thickness between 1 μm and 2 μm whereas the optimum buffer layer thickness would be within the range of 0.04–0.06 μm. Among all the cells with various buffer layers, the best energy conversion efficiency of 24.62% has been achieved for the ZnO buffer layer based cell. The simulation results with ZnS and ZnO based buffer layer materials instead of using CdS indicate that the cell performance would be better than that of the CdS buffer layer based cell. Although the cells with ZnS(O,OH, ZTO, ZnSe, and In2S3 buffer layers provide slightly lower efficiencies than that of the CdS buffer based cell, the use of these materials would not be deleterious for the environment because of their non-carcinogenic and non-toxic nature.

  17. Opto-electronic characterization of polycrystalline CuInS{sub 2} and Cu(In,Ga)S{sub 2} absorber layers by photoluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Heidemann, Florian

    2011-09-29

    Photoluminescence (PL) is an established method to characterize the optoelectronic properties of solar cell absorber layers. With the help of Planck's generalized law it is in principle possible to determine the quasi-Fermi level splitting - which is the upper limit of the open circuit voltage V{sub oc} - and the absorption coefficient of a solar cell before its actual completion. For large-scale measurements (mm/cm regime) this is valid for absorber layers with lateral homogeneous properties, however it is not directly transferable to polycrystalline semiconductors due to laterally fluctuating opto-electronic and structural parameters. The lateral fluctuations in opto-electronic properties of polycrystalline Cu(In{sub 1-{xi}}Ga{sub {xi}})S{sub 2} have been analyzed (e.g. with respect to fluctuations in quasi-Fermi level splitting, optical band-gap and sub band-gap absorbance) by measuring laterally and spectrally resolved PL on the {mu}m-scale and providing the transition towards macroscopic PL measurements on the mm-scale. To give a comprehensive characterization, surface roughness and optical properties have been studied and methods for feature extraction have been applied. On the microscopic scale variations in the quasi-Fermi level splitting {delta}{sub x,y}E{sub Fnp} of about 38 meV (CuInS{sub 2}) and 53 meV (Cu(In,Ga)S{sub 2}) have been found. From local absorbance spectra extracted from PL measurements on Cu(In,Ga)S{sub 2} fluctuations in the optical band-gap E{sub opt} with a full width at half maximum of FWHM{sub E{sub opt}}{approx}80 meV could be extracted, whereas band-gap fluctuations in CuInS{sub 2} are found to be negligible. Thus band-gap fluctuations seem to be mainly caused by a varying gallium (Ga) content. Furthermore, regions with higher E{sub opt} and with it a potential higher Ga content, show a higher quasi-Fermi level splitting. As a major limiting factor for the local quasi-Fermi level splitting E{sub Fnp} the local density of deep

  18. Low Absorbance Measurements

    Science.gov (United States)

    Harris, T. D.; Williams, A. M.

    1983-10-01

    The application of low absorption measurements to dilute solute determination requires specific instrumental characteristics. The use of laser intracavity absorption and thermal lens calorimetry to measure concentration is shown. The specific operating parameters that determine sensitivity are delineated along with the limits different measurement strategies impose. Finally areas of improvement in components that would result in improve sensitivity, accuracy, and reliability are discussed. During the past decade, a large number of methods have been developed for measuring the light absorbed by transparent materials. These include measurements on gases, liquids, and solids. The activity has been prompted by a variety of applications and a similar variety of disciplines. In Table 1 some representative examples of these methods is shown along with their published detection limits.1 It is clear that extraordinarily small absorbances can be measured. Most of the methods can be conveniently divided into two groups. These groups are those that measure the transmission of the sample and those that measure the light absorbed by the sample. The light absorbed methods are calorimetric in character. The advantages and disadvantages of each method varies depending on the principal application for which they were developed. The most prevalent motivation has been to characterize the bulk optical properties of transparent materials. Two examples are the development of extremely transparent glasses for use as fiber optic materials and the development of substrates for high power laser operation.

  19. Black Cr/a-Cr2O3 nanoparticles based solar absorbers

    CSIR Research Space (South Africa)

    Khamlich, S

    2012-01-01

    Full Text Available and attenuated total reflection, as well as UV–vis diffuse reflectance spectroscopy. The samples aged for more than 40 h at 75 °C exhibit the targeted high absorbing optical characteristic “Black chrome” while those aged for =40 h show a significant high UV–vis...

  20. Reduction in 2-year recurrent risk score and improved behavioral outcomes after participation in the "Beating Heart Problems" self-management program: results of a randomized controlled trial.

    Science.gov (United States)

    Murphy, Barbara M; Worcester, Marian U C; Higgins, Rosemary O; Elliott, Peter C; Le Grande, Michael R; Mitchell, Fiona; Navaratnam, Hema; Turner, Alyna; Grigg, Leeanne; Tatoulis, James; Goble, Alan J

    2013-01-01

    While behavior change can improve risk factor profiles and prognosis after an acute cardiac event, patients need assistance to achieve sustained lifestyle changes. We developed the "Beating Heart Problems" cognitive-behavioral therapy and motivational interviewing program to support patients to develop behavioral and cognitive self-management skills. We report the results of a randomized controlled trial of the program. Patients (n = 275) consecutively admitted to 2 Melbourne hospitals after acute myocardial infarction (32%), coronary artery bypass graft surgery (40%), or percutaneous coronary intervention (28%) were randomized to treatment (T; n = 139) or control (C; n = 136). T group patients were invited to participate in the 8-week group-based program. Patients underwent risk factor screening 6 weeks after hospital discharge (before randomization) and again 4 and 12 months later. At both the followups, T and C groups were compared on 2-year risk of a recurrent cardiac event and key behavioral outcomes, using both intention-to-treat and "completers only" analyses. Patients ranged in age from 32 to 75 years (mean = 59.0 years; SD - 9.1 years). Most patients (86%) were men. Compared with the C group patients, T group patients tended toward greater reduction in 2-year risk, at both the 4- and 12-month followups. Significant benefits in dietary fat intake and functional capacity were also evident. The "Beating Heart Problems" program showed modest but important benefit over usual care at 4 and, to a lesser extent, 12 months. Modifications to the program such as the inclusion of booster sessions and translation to online delivery are likely to improve outcomes.

  1. Application of evolution strategy algorithm for optimization of a single-layer sound absorber

    Directory of Open Access Journals (Sweden)

    Morteza Gholamipoor

    2014-12-01

    Full Text Available Depending on different design parameters and limitations, optimization of sound absorbers has always been a challenge in the field of acoustic engineering. Various methods of optimization have evolved in the past decades with innovative method of evolution strategy gaining more attention in the recent years. Based on their simplicity and straightforward mathematical representations, single-layer absorbers have been widely used in both engineering and industrial applications and an optimized design for these absorbers has become vital. In the present study, the method of evolution strategy algorithm is used for optimization of a single-layer absorber at both a particular frequency and an arbitrary frequency band. Results of the optimization have been compared against different methods of genetic algorithm and penalty functions which are proved to be favorable in both effectiveness and accuracy. Finally, a single-layer absorber is optimized in a desired range of frequencies that is the main goal of an industrial and engineering optimization process.

  2. Process intensification characteristics of a microreactor absorber for enhanced CO_2 capture

    International Nuclear Information System (INIS)

    Ganapathy, Harish; Steinmayer, Sascha; Shooshtari, Amir; Dessiatoun, Serguei; Ohadi, Michael M.; Alshehhi, Mohamed

    2016-01-01

    Highlights: • Enhanced gas separation/CO_2 capture using aqueous DEA in micro-structured absorber. • 15 straight parallel channels with hydraulic diameter of 456 μm. • Achieved close to 100% absorption efficiency under certain operating conditions. • Mass transfer coefficients 1–3 orders of magnitude higher than conventional absorbers. • Substantial intensification of absorption process achievable using microreactors. - Abstract: Gas separation processes, including post-combustion carbon capture (PCCC) by chemical absorption using liquid solvents can be substantially enhanced using high performance micro-structured surfaces to enhance the surface area available for reaction. The present paper studies the hydrodynamics and mass transfer performance of gas–liquid absorption of CO_2 into aqueous diethanolamine in a micro-structured reactor. The system was designed to comprise 15 straight parallel channels in a cross flow inlet configuration. The hydraulic diameter of each channel was 456 μm. The performance of the reactor was studied with respect to the absorption efficiency, mass transfer coefficient, acid gas loading ratio, and pressure drop. A flow pattern map was developed using available regime transition criteria. Parametric studies varying the gas and liquid flow rates, as well as their respective concentrations at the reactor inlet, were conducted. The two-phase pressure drop was compared against the predictions of a piecewise model and a reasonably good agreement was obtained. Absorption efficiencies close to 100% were observed under certain operating conditions. The presently achieved values of liquid-side volumetric mass transfer coefficients were between 1–3 orders of magnitude higher than those reported for most conventional gas–liquid absorption systems, which can be attributed to the inherent high specific interfacial area provided through micro-structured surfaces. The results reported here indicate the substantial levels of process

  3. Liquid metal reactor absorber technology

    International Nuclear Information System (INIS)

    Pitner, A.L.

    1990-10-01

    The selection of boron carbide as the reference liquid metal reactor absorber material is supported by results presented for irradiation performance, reactivity worth compatibility, and benign failure consequences. Scram response requirements are met easily with current control rod configurations. The trend in absorber design development is toward larger sized pins with fewer pins per bundle, providing economic savings and improved hydraulic characteristics. Very long-life absorber designs appear to be attainable with the application of vented pin and sodium-bonded concepts. 3 refs., 3 figs

  4. On the definition of absorbed dose

    International Nuclear Information System (INIS)

    Grusell, Erik

    2015-01-01

    Purpose: The quantity absorbed dose is used extensively in all areas concerning the interaction of ionizing radiation with biological organisms, as well as with matter in general. The most recent and authoritative definition of absorbed dose is given by the International Commission on Radiation Units and Measurements (ICRU) in ICRU Report 85. However, that definition is incomplete. The purpose of the present work is to give a rigorous definition of absorbed dose. Methods: Absorbed dose is defined in terms of the random variable specific energy imparted. A random variable is a mathematical function, and it cannot be defined without specifying its domain of definition which is a probability space. This is not done in report 85 by the ICRU, mentioned above. Results: In the present work a definition of a suitable probability space is given, so that a rigorous definition of absorbed dose is possible. This necessarily includes the specification of the experiment which the probability space describes. In this case this is an irradiation, which is specified by the initial particles released and by the material objects which can interact with the radiation. Some consequences are discussed. Specific energy imparted is defined for a volume, and the definition of absorbed dose as a point function involves the specific energy imparted for a small mass contained in a volume surrounding the point. A possible more precise definition of this volume is suggested and discussed. Conclusions: The importance of absorbed dose motivates a proper definition, and one is given in the present work. No rigorous definition has been presented before. - Highlights: • A stringent definition of absorbed dose is given. • This requires the definition of an irradiation and a suitable probability space. • A stringent definition is important for an understanding of the concept absorbed dose

  5. WARM GAS IN THE VIRGO CLUSTER. I. DISTRIBUTION OF Lyα ABSORBERS

    International Nuclear Information System (INIS)

    Yoon, Joo Heon; Putman, Mary E.; Bryan, Greg L.; Thom, Christopher; Chen, Hsiao-Wen

    2012-01-01

    The first systematic study of the warm gas (T = 10 4–5 K) distribution across a galaxy cluster is presented using multiple background QSOs in and around the Virgo Cluster. We detect 25 Lyα absorbers (N HI = 10 13.1–15.4 cm –2 ) in the Virgo velocity range toward 9 of 12 QSO sightlines observed with the Cosmic Origin Spectrograph, with a cluster impact parameter range of 0.36-1.65 Mpc (0.23-1.05 R vir ). Including 18 Lyα absorbers previously detected by STIS or GHRS toward 7 of 11 background QSOs in and around the Virgo Cluster, we establish a sample of 43 absorbers toward a total of 23 background probes for studying the incidence of Lyα absorbers in and around the Virgo Cluster. With these absorbers, we find (1) warm gas is predominantly in the outskirts of the cluster and avoids the X-ray-detected hot intracluster medium (ICM). Also, Lyα absorption strength increases with cluster impact parameter. (2) Lyα-absorbing warm gas traces cold H I-emitting gas in the substructures of the Virgo Cluster. (3) Including the absorbers associated with the surrounding substructures, the warm gas covering fraction (100% for N HI > 10 13.1 cm –2 ) is in agreement with cosmological simulations. We speculate that the observed warm gas is part of large-scale gas flows feeding the cluster both in the ICM and galaxies.

  6. Vitreous loss-causes, associations, and outcomes: Eight-year analysis in Melaka Hospital

    Directory of Open Access Journals (Sweden)

    Thanigasalam Thevi

    2018-01-01

    CONCLUSION: Vitreous loss occurred in almost all types of cataract surgeries, especially by junior surgeons, among those aged <40 years and significantly caused poor visual outcome compared to other complications. Pseudoexfoliation had higher occurrence of vitreous loss. Vitreous loss patients had impaired/poor visual outcome due to preexisting comorbidity and astigmatism. Patients at risk and junior surgeons should be closely monitored to improve outcomes. Further studies need to be done to see why and when the vitreous loss occurred.

  7. Long-term intrathecal baclofen: outcomes after more than 10 years of treatment.

    Science.gov (United States)

    Mathur, Sunjay N; Chu, Samuel K; McCormick, Zack; Chang Chien, George C; Marciniak, Christina M

    2014-06-01

    To report outcomes of intrathecal baclofen (ITB) therapy for spasticity management in a cohort of patients who had received this treatment for at least 10 years. A cross-sectional survey and retrospective chart review. An academic rehabilitation outpatient clinic. Adult patients with spasticity treated with ITB for at least 10 years. Surveys included the Brief Pain Inventory, Penn Spasm Frequency Scale, Epworth Sleepiness Scale, Fatigue Severity Scale, Diener Satisfaction with Life, Life Satisfaction Questionnaire, and Intrathecal Baclofen Survey. Twenty-four subjects completed the surveys. The subjects had been treated with ITB from 10.0-28.4 years, with a mean (standard deviation) of 14.7 ± 4.2 years. The mean (standard deviation) dose of ITB was 627.9 ± 306.7 μg/d, with only 6 subjects averaging daily dose changes of more than 10% compared with 3 years earlier. The mean (standard deviation) scores on outcomes surveys were the following: 2.6 ± 2.3 for pain severity on the Brief Pain Inventory, 1.4 ± 0.7 for spasm severity on the Penn Spasm Frequency Scale, 7.9 ± 5.4 on the Epworth Sleepiness Scale, 4.1 ± 1.6 on the Fatigue Severity Scale, 19.4 ± 8.1 on the Diener Satisfaction with Life, 3.9 ± 0.9 on the Life Satisfaction Questionnaire, and 8.8 ± 1.9 for overall satisfaction with ITB on the Intrathecal Baclofen Survey. On the Brief Pain Inventory, the mean scores for pain severity and interference of pain with life showed moderate inverse correlations with ITB dose (r = -0.386, P = .115; and r = -0.447, P = .062, respectively). On the Life Satisfaction Questionnaire, the mean scores for life satisfaction showed statistically significant positive correlation with ITB dose (r = 0.549, P = .021). The subjects reported low levels of pain, moderate levels of life satisfaction, normal levels of sleepiness, low-to-moderate levels of fatigue, infrequent spasms at mild-to-moderate severity, and high levels of satisfaction. The efficacy and favorable adverse

  8. Satisfactory surgical outcome of T2 gastric cancer after modified D2 lymphadenectomy.

    Science.gov (United States)

    Zhang, Shupeng; Wu, Liangliang; Wang, Xiaona; Ding, Xuewei; Liang, Han

    2017-04-01

    Though D2 lymphadenectomy has been increasingly regarded as standard surgical procedure for advanced gastric cancer (GC), the modified D2 (D1 + 7, 8a and 9) lymphadenectomy may be more suitable than D2 dissection for T2 stage GC. The purpose of this study is to elucidate whether the surgical outcome of modified D2 lymphadenectomy was comparable to that of standard D2 dissection in T2 stage GC patients. A retrospective cohort study with 77 cases and 77 controls matched for baseline characteristics was conducted. Patients were categorized into two groups according to the extent of lymphadenectomy: the modified D2 group (mD2) and the standard D2 group (D2). Surgical outcome and recurrence date were compared between the two groups. The 5-year overall survival (OS) rate was 71.4% for patients accepted mD2 lymphadenectomy and 70.1% for those accepted standard D2, respectively, and the difference was not statistically significant. Multivariate survival analysis revealed that curability, tumor size, TNM stage and postoperative complications were independently prognostic factors for T2 stage GC patients. Patients in the mD2 group tended to have less intraoperative blood loss (P=0.001) and shorter operation time (P<0.001) than those in the D2 group. While there were no significant differences in recurrence rate and types, especially lymph node recurrence, between the two groups. The surgical outcome of mD2 lymphadenectomy was equal to that of standard D2, and the use of mD2 instead of standard D2 can be a better option for T2 stage GC.

  9. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography: Insights From the ABSORB Cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions).

    Science.gov (United States)

    Onuma, Yoshinobu; Grundeken, Maik J; Nakatani, Shimpei; Asano, Taku; Sotomi, Yohei; Foin, Nicolas; Ng, Jaryl; Okamura, Takayuki; Wykrzykowska, Joanna J; de Winter, Robbert J; van Geuns, Robert-Jan; Koolen, Jacques; Christiansen, Evald; Whitbourn, Robert; McClean, Dougal; Smits, Pieter; Windecker, Stephan; Ormiston, John A; Serruys, Patrick W

    2017-09-01

    The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb bioresorbable vascular scaffold struts. We performed 3-dimensional optical coherence tomographic analysis of the ABSORB Cohort B trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) up to 5 years using a novel, validated cut-plane analysis method. We included 29 patients with a total of 85 side branch ostia. From the 12 ostia which could be assessed in true serial fashion, 7 showed a pattern of initial decrease in the ostial area free from struts, followed by an increase in strut-free ostial area toward the end of the 5 years of follow-up. In a repeated-measures analysis with time as fixed variable and ostial area free from struts as dependent variable, we showed a numeric decrease in the estimated ostial area free from struts from 0.75 mm 2 (baseline) to 0.68 mm 2 (first follow-up visit at 6 months or 1 year) and 0.63 mm 2 (second follow-up visit at 2 or 3 years). However, from the second visit to the 5-year follow-up visit, there was a statistically significant increase from 0.63 to 0.89 mm 2 ( P =0.001). Struts overlying an ostium divided the ostium into compartments, and the number of these compartments decreased over time. This study showed that in most cases, the side branch ostial area free from struts initially decreased. However, with full scaffold bioresorption, the ostial area free from scaffold increased between 2 to 3 years and 5 years in the vast majority of patients. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00856856. © 2017 American Heart Association, Inc.

  10. Optical properties of selectively absorbing C/NiO nanocomposite coatings

    CSIR Research Space (South Africa)

    Roro, Kittessa T

    2010-12-01

    Full Text Available Nanocomposite thin films are widely used for solar thermal applications. Using carbon nanoparticle containing metal oxide as a spectrally selective solar absorber coating has grown significantly in recent years. Recently, Katumba et al. have...

  11. Preparation of CuGaSe2 absorber layers for thin film solar cells by annealing of efficiently electrodeposited Cu-Ga precursor layers from ionic liquids

    International Nuclear Information System (INIS)

    Steichen, M.; Larsen, J.; Guetay, L.; Siebentritt, S.; Dale, P.J.

    2011-01-01

    CuGaSe 2 absorber layers were prepared on molybdenum substrates by electrochemical codeposition of copper and gallium and subsequential annealing in selenium vapour. The electrodeposition was made from a deep eutectic based ionic liquid consisting of choline chloride/urea (Reline) with a plating efficiency of over 85%. The precursor film composition is controlled by the ratio of the copper to gallium fluxes under hydrodynamic conditions and by the applied deposition potential. X-ray diffraction reveals CuGa 2 alloying during the electrodeposition and CuGaSe 2 formation after annealing. Photoluminescence (PL) and photocurrent spectroscopy revealed the good opto-electronic properties of the CuGaSe 2 absorber films. The absorber layers have been converted to full devices with the best device achieving 4.0 % solar conversion efficiency.

  12. Development of the electrochemically regenerable carbon dioxide absorber for portable life support system application

    Science.gov (United States)

    Woods, R. R.; Heppner, D. B.; Marshall, R. D.; Quattrone, P. D.

    1979-01-01

    As the length of manned space missions increase, more ambitious extravehicular activities (EVAs) are required. For the projected longer mission the use of expendables in the portable life support system (PLSS) will become prohibited due to high launch weight and volume requirements. Therefore, the development of a regenerable CO2 absorber for the PLSS application is highly desirable. The paper discusses the concept, regeneration mechanism, performance, system design, and absorption/regeneration cycle testing of a most promising concept known as ERCA (Electrochemically Regenerable CO2 Absorber). This concept is based on absorbing CO2 into an alkaline absorbent similar to LiOH. The absorbent is an aqueous solution supported in a porous matrix which can be electrochemically regenerated on board the primary space vehicle. With the metabolic CO2 recovery the ERCA concept results in a totally regenerable CO2 scrubber. The ERCA test hardware has passed 200 absorption/regeneration cycles without performance degradation.

  13. Stretchable Metamaterial Absorber Using Liquid Metal-Filled Polydimethylsiloxane (PDMS

    Directory of Open Access Journals (Sweden)

    Kyeongseob Kim

    2016-04-01

    Full Text Available A stretchable metamaterial absorber is proposed in this study. The stretchability was achieved by liquid metal and polydimethylsiloxane (PDMS. To inject liquid metal, microfluidic channels were fabricated using PDMS powers and microfluidic-channel frames, which were built using a three-dimensional printer. A top conductive pattern and ground plane were designed after considering the easy injection of liquid metal. The proposed metamaterial absorber comprises three layers of PDMS substrate. The top layer is for the top conductive pattern, and the bottom layer is for the meandered ground plane. Flat PDMS layers were inserted between the top and bottom PDMS layers. The measured absorptivity of the fabricated absorber was 97.8% at 18.5 GHz, and the absorption frequency increased from 18.5 to 18.65 GHz as the absorber was stretched from its original length (5.2 cm to 6.4 cm.

  14. Desorption of absorbed iron in bean root and leaf tissues

    International Nuclear Information System (INIS)

    Jooste, J.H.; De Bruyn, J.A.

    1979-01-01

    The effect of different desorption media on the amount of absorbed Fe (from a solution of FeCl 3 in 0,5 mM CaCl 2 ) retained by leaf discs and excised root tips of bean plants was investigated. Attempts were also made to determine the effect of desorption on the intracellular distribution of Fe. Desorption in water or an FeCl 3 solution had no pronounced effect on the amount of absorbed Fe retained by either the leaf or root tissues. However, Na 2 -EDTA was able to desorb a considerable portion of the absorbed Fe, especially in root tissue. This applies to Fe absorbed from solutions of FeCl 3 and Fe-EDDHA. Desorption by the chelate removed Fe from practically all the different particulate fractions of both root and leaf tissues, but desorption following the longer absorption periods resulted in an increase in the Fe content of the 'soluble' fraction. The possibility that Na 2 -EDTA causes an increased permeability of cell membranes seems likely. The view that removal of Ca by the chelate causes this increase in permeability could not be confirmed [af

  15. Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

    Science.gov (United States)

    Smith, S. J.; Adams, J. S.; Bandler, S. R.; Busch, S. E.; Chervenak, J. A.; Eckart, M. E.; Ewin, A. J.; Finkbeiner, F. M.; Kelley, R. L.; Kelly, D. P.; hide

    2012-01-01

    We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

  16. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.; Buchpiguel, C. A. [Cancer Institute of São Paulo State (ICESP), Clinical Hospital, School of Medicine, University of São Paulo, São Paulo 01246-000 (Brazil); Nuclear Medicine Service, Department of Radiology, School of Medicine, University of São Paulo, Sao Paulo 01246-000 (Brazil); Watanabe, T. [Nuclear Medicine Service, Department of Radiology, School of Medicine, University of São Paulo, São Paulo 01246-000 (Brazil); Traino, A. C. [Unit of Medical Physics, Azienda Ospedaliero-Universitaria Pisana, Pisa 56126 (Italy)

    2014-01-15

    Purpose: The precise determination of organ mass (m{sub th}) and total number of disintegrations within the thyroid gland (A{sup ~}) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose–response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves’ disease (GD) treatment planning were calculated using different approaches to estimating the m{sub th} and the A{sup ~}. Methods: Fifty patients were included in the study. Thyroid{sup 131}I uptake measurements were performed at 2, 6, 24, 48, 96, and 220 h postadministration of a tracer activity in order to estimate the effective half-time (T{sub eff}) of {sup 131}I in the thyroid; the thyroid cumulated activity was then estimated using the T{sub eff} thus determined or, alternatively, calculated by numeric integration of the measured time-activity data. Thyroid mass was estimated by ultrasonography (USG) and scintigraphy (SCTG). Absorbed doses were calculated with the OLINDA/EXM software. The relationships between thyroid absorbed dose and therapy response were evaluated at 3 months and 1 year after therapy. Results: The average ratio (±1 standard deviation) betweenm{sub th} estimated by SCTG and USG was 1.74 (±0.64) and that between A{sup ~} obtained by T{sub eff} and the integration of measured activity in the gland was 1.71 (±0.14). These differences affect the calculated absorbed dose. Overall, therapeutic success, corresponding to induction of durable hypothyroidism or euthyroidism, was achieved in 72% of all patients at 3 months and in 90% at 1 year. A therapeutic success rate of at least 95% was found in the group of patients receiving doses of 200 Gy (p = 0.0483) and 330 Gy (p = 0.0131) when m{sub th} was measured by either USG or SCTG and A

  17. The psychopathological and psychosocial outcome of early-onset schizophrenia: Preliminary data of a 13-year follow-up

    Directory of Open Access Journals (Sweden)

    Mehler-Wex Claudia

    2008-02-01

    Full Text Available Abstract Background Relatively little is known about the long-term psychopathological and psychosocial outcome of early-onset schizophrenia. The existing literature describes more severe courses of illness in these patients compared with adult-onset schizophrenia. This article reports preliminary data of a study exploring the outcome of early-onset schizophrenia 13.4 years (mean after first admission. Predictors for interindividual outcomes were investigated. Methods We retrospectively assessed 27 former patients (mean age at first admission 15.5 years, SD = 2.0 that were consecutively admitted to the Department of Child and Adolescent Psychiatry at the University of Wuerzburg between 1990 and 2000. A multidimensional approach was chosen to assess the outcome consisting of a mail survey including different questions about psychopathological symptoms, psychosocial parameters, and standardized self-reports (ESI and ADS. Results Concerning the psychopathological outcome, 22.2% reported having acute schizophrenic symptoms. Almost one third (30.8% described symptoms of depression and 37.0% reported having tried to commit suicide or seriously thought about it. 77.8% of the former patients were still in outpatient treatment. Compared to the general population, the number of patients without a school graduation was relatively high (18.5%. Almost half of participants still live with their parents (48.1% or in assisted or semi-assisted living conditions (33.3%. Only 18.5% were working in the open market. Conclusion Schizophrenia with an early onset has an unfavourable prognosis. Our retrospective study of the psychopathological and psychosocial outcome concludes with a generally poor rating.

  18. Absorbed Doses to Patients in Nuclear Medicine; Doskatalogen foer nukleaermedicin

    Energy Technology Data Exchange (ETDEWEB)

    Leide-Svegborn, Sigrid; Mattsson, Soeren; Nosslin, Bertil [Universitetssjukhuset MAS, Malmoe (Sweden). Avd. foer radiofysik; Johansson, Lennart [Norrlands Universitetssjukhus, Umeaa (Sweden). Avd. foer radiofysik

    2004-09-01

    The work with a Swedish catalogue of radiation absorbed doses to patients undergoing nuclear medicine investigations has continued. After the previous report in 1999, biokinetic data and dose estimates (mean absorbed dose to various organs and tissues and effective dose) have been produced for a number of substances: {sup 11}C- acetate, {sup 11}C- methionine, {sup 18}F-DOPA, whole antibody labelled with either {sup 99m}Tc, {sup 111}In, {sup 123}I or {sup 131}I, fragment of antibody, F(ab'){sub 2} labelled with either {sup 99m}Tc, {sup 111}In, {sup 123}I or {sup 131}I and fragment of antibody, Fab' labelled with either {sup 99m}Tc, {sup 111}In, {sup 123}I or {sup 131}I. The absorbed dose estimates for these substances have been made from published biokinetic information. For other substances of interest, e.g. {sup 14}C-urea (children age 3-6 years), {sup 14}C-glycocholic acid, {sup 14}C-xylose and {sup 14}C-triolein, sufficient literature data have not been available. Therefore, a large number of measurements on patients and volunteers have been carried out, in order to determine the biokinetics and dosimetry for these substances. Samples of breast milk from 50 mothers, who had been subject to nuclear medicine investigations, have been collected at various times after administration of the radiopharmaceutical to the mother. The activity concentration in the breast milk samples has been measured. The absorbed dose to various organs and tissues and the effective dose to the child who ingests the milk have been determined for 17 different radiopharmaceuticals. Based on these results revised recommendations for interruption of breast-feeding after nuclear medicine investigations are suggested.

  19. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  20. Benchmark solution of contemporary PWR integral fuel burnable absorbers

    International Nuclear Information System (INIS)

    Stucker, D.L.; Hone, M.J.; Holland, R.A.

    1993-01-01

    This paper presents a closely controlled benchmark solution of the two major contemporary pressurized water reactor integral burnable absorber designs: zirconium diboride (ZrB 2 ) and gadolinia (Gd 2 O 3 ). The comparison is accomplished using self-generating equilibrium cycles with equal energy, equal discharge burnup, and equal safety constraints. The reference plant for this evaluation is a 3411-MW(thermal) Westinghouse four-loop nuclear steam supply system operating with an inlet temperature of 285.9 degrees C, a core coolant mass now rate of 16877.3 kg/s, and coolant pressure of 15.5 MPa. The reactor consists of 193 VANTAGE 5H fuel assemblies that are discharged at a region average burnup of 48.4 GWd/tonne U. Each fuel assembly contains a natural uranium axial blanket 15.24 cm long at the top and the bottom of the fuel rod. The burnable absorber rods are symmetrically radially dispersed within the fuel assembly such that intrabundle power peaking is minimized. The burnable absorber material for both ZrB 2 and Gd 2 O 3 is axially zoned to the central 304.8 cm of the absorber-bearing fuel rods. The fuel management was constrained such that the thermal and safety limitations of F δH q -5 /degrees C were simultaneously achieved. The maximum long-term operating soluble boron concentration was also limited to 446 effective full-power days (EFPDs) including 14 EFPDs of power coastdown were assumed

  1. Long-Term Outcomes of Homografts in the Aortic Valve and Root Position: A 20-Year Experience

    Directory of Open Access Journals (Sweden)

    Joo Yeon Kim

    2016-08-01

    Full Text Available Background: The advantages of using a homograft in valve replacement surgery are the excellent hemodynamic profile, low risk of thromboembolism, and low risk of prosthetic valve infection. The aim of this study was to evaluate the long-term outcomes of homograft implantation in the aortic valve position. Methods: This is a retrospective study of 33 patients (>20 years old who underwent aortic valve replacement or root replacement with homografts between April 1995 and May 2015. Valves were collected within 24 hours from explanted hearts of heart transplant recipients (<60 years and organ donors who were not suitable for heart transplantation. The median follow-up duration was 35.6 months (range, 0 to 168 months. Results: Aortic homografts were used in all patients. The 30-day mortality rate was 9.1%. The 1- and 5-year survival rates were 80.0%±7.3% and 60.8%±10.1%, respectively. The 1-, 5-, and 10-year freedom from reoperation rates were 92.3%±5.2%, 68.9%±10.2%, and 50.3%±13.6%, respectively. The 1-, 5-, and 10-year freedom from significant aortic dysfunction rates were 91.7%±8.0%, 41.7%±14.2%, and 25.0%±12.5%, respectively. Conclusion: Homografts had the advantages of a good hemodynamic profile and low risk of thromboembolic events, and with good outcomes in cases of aortitis.

  2. Aluminum alloy excellent in neutron absorbing performance

    International Nuclear Information System (INIS)

    Iida, Tetsuya; Tamamura, Tadao; Morimoto, Hiroyuki; Ouchi, Ken-ichiro.

    1987-01-01

    Purpose: To obtain structural materials made of aluminum alloys having favorable neutron absorbing performance and excellent in the performance as structural materials such as processability and strength. Constitution: Powder of Gd 2 O 3 as a gadolinium compound or metal gadolinium is uniformly mixed with the powder of aluminum or aluminum alloy. The amount of the gadolinium compound added is set to 0.1 - 30 % by weight. No sufficient neutron absorbing performance can be obtained if it is less than 0.1 % by weight, whereas the processability and mechanical property of the alloy are degraded if it exceeds 30 % by weight. Further, the grain size is set to less about 50 μm. Further, since the neutron absorbing performance varies greatly if the aluminum powder size exceeds 100 μm, the diameter is set to less than about 100 μm. These mixtures are molded in a hot press. This enables to obtain aimed structural materials. (Takahashi, M.)

  3. Surgical decompression for space-occupying cerebral infarction: outcomes at 3 years in the randomized HAMLET trial.

    Science.gov (United States)

    Geurts, Marjolein; van der Worp, H Bart; Kappelle, L Jaap; Amelink, G Johan; Algra, Ale; Hofmeijer, Jeannette

    2013-09-01

    We assessed whether the effects of surgical decompression for space-occupying hemispheric infarction, observed at 1 year, are sustained at 3 years. Patients with space-occupying hemispheric infarction, who were enrolled in the Hemicraniectomy After Middle cerebral artery infarction with Life-threatening Edema Trial within 4 days after stroke onset, were followed up at 3 years. Outcome measures included functional outcome (modified Rankin Scale), death, quality of life, and place of residence. Poor functional outcome was defined as modified Rankin Scale >3. Of 64 included patients, 32 were randomized to decompressive surgery and 32 to best medical treatment. Just as at 1 year, surgery had no effect on the risk of poor functional outcome at 3 years (absolute risk reduction, 1%; 95% confidence interval, -21 to 22), but it reduced case fatality (absolute risk reduction, 37%; 95% confidence interval, 14-60). Sixteen surgically treated patients and 8 controls lived at home (absolute risk reduction, 27%; 95% confidence interval, 4-50). Quality of life improved between 1 and 3 years in patients treated with surgery. In patients with space-occupying hemispheric infarction, the effects of decompressive surgery on case fatality and functional outcome observed at 1 year are sustained at 3 years. http://www.controlled-trials.com. Unique identifier: ISRCTN94237756.

  4. A Rights-Based Sexuality Education Curriculum for Adolescents: 1-Year Outcomes From a Cluster-Randomized Trial.

    Science.gov (United States)

    Rohrbach, Louise A; Berglas, Nancy F; Jerman, Petra; Angulo-Olaiz, Francisca; Chou, Chih-Ping; Constantine, Norman A

    2015-10-01

    The purpose of this study was to evaluate the impact of a rights-based sexuality education curriculum on adolescents' sexual health behaviors and psychosocial outcomesyear after participation. Within 10 urban high schools, ninth-grade classrooms were randomized to receive a rights-based curriculum or a basic sex education (control) curriculum. The intervention was delivered across two school years (2011-2012, 2012-2013). Surveys were completed by 1,447 students at pretest and 1-year follow-up. Multilevel analyses examined curriculum effects on behavioral and psychosocial outcomes, including four primary outcomes: pregnancy risk, sexually transmitted infection risk, multiple sexual partners, and use of sexual health services. Students receiving the rights-based curriculum had higher scores than control curriculum students on six of nine psychosocial outcomes, including sexual health knowledge, attitudes about relationship rights, partner communication, protection self-efficacy, access to health information, and awareness of sexual health services. These students also were more likely to report use of sexual health services (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) and more likely to be carrying a condom (odds ratio, 1.97; 95% confidence interval, 1.39-2.80) relative to those receiving the control curriculum. No effects were found for other sexual health behaviors, possibly because of low prevalence of sexual activity in the sample. The curriculum had significant, positive effects on psychosocial and some behavioral outcomesyear later, but it might not be sufficient to change future sexual behaviors among younger adolescents, most of whom are not yet sexually active. Booster education sessions might be required throughout adolescence as youth initiate sexual relationships. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  5. Comparison in outcomes at two-years of age of very preterm infants born in 2000, 2005 and 2010.

    Directory of Open Access Journals (Sweden)

    Lénaïg Abily-Donval

    Full Text Available To investigate alteration in 2-year neurological/behavioral outcomes of very preterm infants born in a French level three neonatal intensive care unit.We conducted a prospective, comparative study of very preterm infants born before 33 weeks' gestation at 5-year intervals in 2000, 2005 and 2010 at Rouen University Hospital. Neonatal mortality/morbidities, ante- and neonatal treatments, and at age 2 years motor, cognitive and behavioral data were collected by standardized questionnaires.We included 536 very preterm infants. Follow-up rates at two years old were 78% in 2000, 93% in 2005 and 92% in 2010 respectively. No difference in gestational age, birthweight, neonatal mortality/morbidities was observed except a decrease in low grade subependymal/intraventricular hemorrhages. Care modifications concerned use of antenatal magnesium sulfate, breast-feeding and post-natal corticosteroid therapy. Significant improvement in motor outcome and dramatic decrease in cerebral palsy rates (12% in 2000, 6% in 2005, 1% in 2010, p<0.001 were observed, as were improvements in feeding behavior. Although a non significant difference to better psychosocial behavior was reported, there was no difference in cognitive outcome.Improvement in neuromotor outcome and behavior was reported. This could be due to multiple modifications in care: including administration of magnesium sulfate to women at risk of preterm birth, increase in breast-feeding, decrease in low grade subependymal/intraventricular hemorrhages, and decrease in post-natal corticosteroid therapy, all of which require further investigation in other studies. Extended follow-up until school age is mandatory for better detection of cognitive, learning and behavioral disorders.

  6. Design and measuring of a tunable hybrid metamaterial absorber for terahertz frequencies

    Science.gov (United States)

    Zhong, Min; Liu, Shui Jie; Xu, Bang Li; Wang, Jie; Huang, Hua Qing

    2018-04-01

    A tunable hybrid metamaterial absorber is designed and experimentally produced in THz band. The hybrid metamaterial absorber contains two dielectric layers: SU-8 and VO2 layers. An absorption peak reaching to 83.5% is achieved at 1.04 THz. The hybrid metamaterial absorber exhibits high absorption when the incident angle reaches to 45°. Measured results indicate that the absorption amplitude and peak frequency of the hybrid metamaterial absorber is tunable in experiments. It is due to the insulator-to-metal phase transition is achieved when the measured temperature reaches to 68 °C. Moreover, the hybrid metamaterial absorber reveals high figure of merit (FOM) value when the measured temperature reaches to 68 °C.

  7. Dynamic testing of airplane shock-absorbing struts

    Science.gov (United States)

    Langer, P; Thome, W

    1932-01-01

    Measurement of perpendicular impacts of a landing gear with different shock-absorbing struts against the drum testing stand. Tests were made with pneumatic shock absorbers having various degrees of damping, liquid shock absorbers, steel-spring shock absorbers and rigid struts. Falling tests and rolling tests. Maximum impact and gradual reduction of the impacts in number and time in the falling tests. Maximum impact and number of weaker impacts in rolling tests.

  8. A chiral microwave absorbing absorbent of Fe–CoNiP coated on spirulina

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yonggang, E-mail: xuyonggang221@163.com [Science and Technology on Electromagnetic Scattering Laboratory, Shanghai, 200438 (China); Yuan, Liming [Science and Technology on Electromagnetic Scattering Laboratory, Shanghai, 200438 (China); Zhang, Deyuan [School of Mechanical Engineering and Automation, Beihang University, Beijing, 100191 (China)

    2015-11-15

    A chiral bio-absorbent of Fe–CoNiP coated on the spirulina was fabricated by the electroless and chemical vapor decomposition. The scanning electron microscopy (SEM) was used to evaluate the spirulina cells particle morphology. X-ray diffraction (XRD) patterns were done to analyze the particle crystal grain structure. The permittivity and permeability was measured by a vector network analyzer in frequency 8–18 GHz, and the reflection loss (RL) was calculated. The results showed the carbonyl iron particles (CIPs) and CoNiP were bonded to the spirulina surface, the permittivity and permeability could be enlarged as Fe films coated on the particles compared with the CoNiP spirulina, it was attributed to the excellent electromagnetic property of CIPs. The chiral Fe–CoNiP composites had a better absorbing property at 8–18 GHz than the CoNiP spirulina composite, the RL was −16.26 dB at 10.48 GHz, the absorbing band was 9.5–11.5 GHz of RL less than −10 dB, which indicated the Fe–CoNiP spirulina could be an effective absorbent used in 8–18 GHz. - Highlights: • Absorbers filled with Fe–CoNiP coating on the spirulina were fabricated. • The permittivity and permeability increased as CIPs coated. • The Fe material enhanced the electromagnetic property. • The spirulina coated Fe–CoNiP was effective in 8–18 GHz.

  9. Absorber rod drive for nuclear reactors

    International Nuclear Information System (INIS)

    Acher, H.

    1985-01-01

    The invention concerns a further addition to the invention of DE 33 42 830 A1. The free contact of the hollow piston with the nut due to hydraulic pressure is replaced by a hydraulic or spring attachment. The pressure system required to produce the hydraulic pressure is therefore omitted, and the electrical power required for driving the pump or the mass flow is also omitted. The absorber rod slotted along its longitudinal axis is replaced by an absorber rod, in the longitudinal axis of which a hollow piston is connected together with the absorber rod. This makes the absorber rod more stable, and assembly is simplified. (orig./HP) [de

  10. Are patient-reported outcomes predictive of patient satisfaction 5 years after anterior cervical spine surgery?

    Science.gov (United States)

    Schroeder, Gregory D; Coric, Dom; Kim, Han Jo; Albert, Todd J; Radcliff, Kris E

    2017-07-01

    Patient satisfaction is becoming an increasing common proxy for surgical quality; however, the correlation between patient satisfaction and surgical outcomes 2 and 5 years after anterior cervical surgery has not been evaluated. The study aimed to determine if patient satisfaction is predicted by improvement in patient-reported outcomes (PRO) 2 and 5 years after anterior cervical spine surgery. This is a retrospective analysis of prospectively collected data. The sample included patients enrolled in the Food and Drug Administration investigational device exemption clinical trial comparing total disc replacement with Mobi-C cervical artificial disc and anterior cervical discectomy and fusion. The outcome measures were visual analog scale (VAS) neck pain score, Neck Disability Index (NDI), and Short-Form 12-Item scores, as well as patient satisfaction. Receiver operating characteristic curves were used to determine if improvement in different PRO metrics can accurately identify patient satisfaction. Additionally, a logistic regression analysis was performed on the results at 24 months and 60 months to identify independent predictors of patient satisfaction. This research was supported by LDR (Zimmer Biomet) 13785 Research Boulevard - Suite 200 Austin, TX 78750. Data were available for 512 patients at 60 months. At 24 months postoperatively, NDI score improvement (area under the curve [AUC]=0.806), absolute NDI score (AUC=0.823), and absolute VAS neck pain score (AUC=0.808) were all excellent predictors of patient satisfaction. At 60 months postoperatively, NDI score improvement (AUC=0.815), absolute NDI score (AUC=0.839), VAS neck pain score improvement (AUC=0.803), and absolute VAS neck pain score (AUC=0.861) were all excellent predictors of patient satisfaction. In patients undergoing one- and two-level anterior cervical spine surgery, between 2 and 5 years postoperatively, patient satisfaction is significantly predicted by PROs, including the VAS neck score and the

  11. Hypofractionated intensity-modulated arc therapy for lymph node metastasized prostate cancer: Early late toxicity and 3-year clinical outcome

    International Nuclear Information System (INIS)

    Fonteyne, Valérie; Lumen, Nicolaas; Ost, Piet; Van Praet, Charles; Vandecasteele, Katrien; De Gersem Ir, Werner; Villeirs, Geert; De Neve, Wilfried; Decaestecker, Karel; De Meerleer, Gert

    2013-01-01

    Background and purpose: For patients with N1 prostate cancer (PCa) aggressive local therapies can be advocated. We evaluated clinical outcome, gastro-intestinal (GI) and genito-urinary (GU) toxicity after intensity modulated arc radiotherapy (IMAT) + androgen deprivation (AD) for N1 PCa. Material and methods: Eighty patients with T1-4N1M0 PCa were treated with IMAT and 2–3 years of AD. A median dose of 69.3 Gy (normalized isoeffective dose at 2 Gy per fraction: 80 Gy [α/β = 3]) was prescribed in 25 fractions to the prostate. The pelvic lymph nodes received a minimal dose of 45 Gy. A simultaneous integrated boost to 72 Gy and 65 Gy was delivered to the intraprostatic lesion and/or pathologically enlarged lymph nodes, respectively. GI and GU toxicity was scored using the RTOG/RILIT and RTOG-SOMA/LENT-CTC toxicity scoring system respectively. Three-year actuarial risk of grade 2 and 3/4 GI–GU toxicity and biochemical and clinical relapse free survival (bRFS and cRFS) were calculated with Kaplan–Meier statistics. Results: Median follow-up was 36 months. Three-year actuarial risk for late grade 3 and 2 GI toxicity is 8% and 20%, respectively. Three-year actuarial risk for late grade 3–4 and 2 GU toxicity was 6% and 34%, respectively. Actuarial 3-year bRFS and cRFS was 81% and 89%, respectively. Actuarial 3-year bRFS and cRFS was, respectively 26% and 32% lower for patients with cN1 disease when compared to patients with cN0 disease. Conclusion: IMAT for N1 PCa offers good clinical outcome with moderate toxicity. Patients with cN1 disease have poorer outcome

  12. Gender reassignment surgery - a 13 year review of surgical outcomes

    Directory of Open Access Journals (Sweden)

    R. Rossi Neto

    2012-02-01

    Full Text Available PURPOSE: The aim of this study is to thoroughly report on surgical outcomes from 332 patients who underwent male to female gender reassignment surgery (GRS. MATERIAL AND METHODS: Records from 332 patients who underwent GRS from 1995 to 2008 were reviewed. All patients were submitted to penile inversion vaginoplasty with glans-derived sensate clitoroplasty. Mean age was 36.7 years (range 19-68 years. Surgical complications were stratified in 6 main groups: genital region, urinary tract, gastrointestinal events, wound healing disorders and unspecific events. RESULTS: Progressive obstructive voiding disorder due to meatal stenosis was the main complication observed in 40% of the patients, feasibly corrected during the second setting. Stricture recurrence was found in 15%. Stricture of vaginal introitus was observed in 15% of the cases followed by 12% and 8% of vaginal stenosis and lost of vaginal depth, respectively. Rectal injury was seen in 3% and minor wound healing disorders in 33% of the subjects. CONCLUSION: Regarding male to female GRS, a review of the current literature demonstrated scarce description of complications and their treatment options. These findings motivated a review of our surgical outcomes. Results showed a great number of adverse events, although functionality preserved. Comparision of our outcomes with recent publications additionally showed that treatment options provide satisfying results. Moreover, outcomes reaffirm penile inversion vaginoplasty in combination with glans-derived sensate clitoroplasty as a safe technique. Nevertheless, discussing and improving surgical techniques in order to reduce complications and their influence on patient's quality of life is still strongly necessary and theme of our future reports.

  13. A comparison of adolescent- and adult-onset first-episode, non-affective psychosis: 2-year follow-up

    DEFF Research Database (Denmark)

    Simonsen, Erik; Langeveld, Johannes; Joa, Inge

    2012-01-01

    This study aimed to compare 2-year outcome among individuals with early-onset (EO; clinical and treatment characteristics of 43 EO and 189 AO patients 2 years after their inclusion in a clinical epidemiologic...... no longer significant at the 2-year follow-up. This study challenges the findings of a larger and older literature base consisting primarily of non-comparative studies concluding that teenage onset indicates a poor outcome. Our results indicate that adolescent-onset and adult-onset psychosis have similar...... prognostic trajectories, although both may predict a qualitatively different course from childhood-onset psychosis....

  14. Evaluation of the distribution of absorbed dose in child phantoms exposed to diagnostic medical x rays

    International Nuclear Information System (INIS)

    Chen, W.L.

    1977-01-01

    The purpose of the study was to determine, by theoretical calculation and experimental measurement, the absorbed dose distributions in two heterogeneous phantoms representing one-year- and five-year-old children from typical radiographic examinations for those ages. Theoretical work included the modification of an existing internal dose code which used Monte Carlo methods to determine doses within the Snyder-Fisher mathematical phantom. A Ge(Li) detector and a pinhole collimator were used to measure x-ray spectra which served as input (i.e., the source routine) to the modified Monte Carlo codes which were used to calculate organ doses in children. Experimental work included the fabrication of child phantoms to match the existing mathematical models. These phantoms were constructed of molded lucite shells filled with differing materials to simulate lung, skeletal, and soft-tissue regions. The skeleton regions of phantoms offered the opportunity to perform meaningful measurements of absorbed dose to bone marrow and bone. Thirteen to fourteen sites in various bones of the skeleton were chosen for placement of TLDs. These sites represented important regions in which active bone marrow is located. Sixteen typical radiographic examinations were performed representing common pediatric diagnostic procedures. The calculated and measured tissue-air values were compared for a number of organs. For most organs, the results of the calculated absorbed doses agreed with the measured absorbed doses within twice the coefficient of variation of the calculated value. The absorbed dose to specific organs for several selected radiological examinations are given for one-year-old, five-year-old, and adult phantoms. For selected radiological exposures, the risk factors of leukemia, thyroid cancer, and genetic death are estimated for one-year- and five-year-old children

  15. An Overview on Impact Behaviour and Energy Absorption of Collapsible Metallic and Non-Metallic Energy Absorbers used in Automotive Applications

    Science.gov (United States)

    Shinde, R. B.; Mali, K. D.

    2018-04-01

    Collapsible impact energy absorbers play an important role of protecting automotive components from damage during collision. Collision of the two objects results into the damage to one or both of them. Damage may be in the form of crack, fracture and scratch. Designers must know about how the material and object behave under impact event. Owing to above reasons different types of collapsible impact energy absorbers are developed. In the past different studies were undertaken to improve such collapsible impact energy absorbers. This article highlights such studies on common shapes of collapsible impact energy absorber and their impact behaviour under the axial compression. The literature based on studies and analyses of effects of different geometrical parameters on the crushing behaviour of impact energy absorbers is presented in detail. The energy absorber can be of different shape such as circular tube, square tube, and frustums of cone and pyramids. The crushing behaviour of energy absorbers includes studies on crushing mechanics, modes of deformation, energy absorbing capacity, effect on peak and mean crushing load. In this work efforts are made to cover major outcomes from past studies on such behavioural parameters. Even though the major literature reviewed is related to metallic energy absorbers, emphasis is also laid on covering literature on use of composite tube, fiber metal lamination (FML) member, honeycomb plate and functionally graded thickness (FGT) tube as a collapsible impact energy absorber.

  16. Ultraviolet absorbance as a proxy for total dissolved mercury in streams

    International Nuclear Information System (INIS)

    Dittman, Jason A.; Shanley, James B.; Driscoll, Charles T.; Aiken, George R.; Chalmers, Ann T.; Towse, Janet E.

    2009-01-01

    Stream water samples were collected over a range of hydrologic and seasonal conditions at three forested watersheds in the northeastern USA. Samples were analyzed for dissolved total mercury (THg d ), DOC concentration and DOC composition, and UV 254 absorbance across the three sites over different seasons and flow conditions. Pooling data from all sites, we found a strong positive correlation of THg d to DOC (r 2 = 0.87), but progressively stronger correlations of THg d with the hydrophobic acid fraction (HPOA) of DOC (r 2 = 0.91) and with UV 254 absorbance (r 2 = 0.92). The strength of the UV 254 absorbance-THg d relationship suggests that optical properties associated with dissolved organic matter may be excellent proxies for THg d concentration in these streams. Ease of sample collection and analysis, the potential application of in-situ optical sensors, and the possibility for intensive monitoring over the hydrograph make this an effective, inexpensive approach to estimate THg d flux in drainage waters. - Ultraviolet absorbance measurements are a cost-effective proxy to estimate dissolved mercury concentration in stream water.

  17. Relevance of positive cardiovascular outcome trial results in clinical practice: perspectives from the Academy for Cardiovascular Risk, Outcomes and Safety Studies in Type 2 Diabetes (ACROSS T2D

    Directory of Open Access Journals (Sweden)

    Schernthaner G

    2017-12-01

    Full Text Available Guntram Schernthaner,1 Kamlesh Khunti,2 Chaim Lotan,3 Michel Burnier,4 Heinz Drexel,5 Martin Prázný61Department of Medicine I, Rudolfstiftung Hospital, Vienna, Austria; 2Diabetes Research Centre, Leicester General Hospital, Leicester, UK; 3Cardiovascular Division, Hadassah Medical Centre, Jerusalem, Israel; 4Division of Nephrology and Hypertension Consultation, University Hospital of Lausanne, Lausanne, Switzerland; 5Vorarlberg Institute for Vascular Investigation and Treatment, Feldkirch, Austria; 6Charles University, Prague, Czech RepublicAbstract: Type 2 diabetes (T2D imposes a substantial disease burden, predominantly from cardiovascular disease (CVD, which accounts for >50% of deaths in this population and leads to a 12-year reduction in the life expectancy of a 60-year-old male patient with T2D and CVD compared with the general population. The results from mandatory cardiovascular outcome trials (CVOTs are therefore of great interest in the field. The Academy for Cardiovascular Risk, Outcomes and Safety Studies in Type 2 Diabetes meeting program aims to bring together experts from several associated disciplines to provide fair and balanced resources for those involved in the management of patients with T2D. This publication represents the opinions of the faculty on the key learnings from the meeting held in Vienna in the spring of 2017. In particular, we detail how data from the EMPA-REG OUTCOME® [cardiovascular outcomes trial of empagliflozin] and Liraglutide Effect and Action in Diabetes: Evaluation of Cardiovascular Outcome Results (LEADER® (liraglutide CVOTs can be practically interpreted across clinical specialities. It is hoped that this translation of CVOT data will achieve a dual treatment paradigm for the management of both raised glucose levels and CV risk in patients with T2D. Keywords: type 2 diabetes, cardiovascular disease, CVOT, SGLT2 inhibitors, GLP-1 agonists, DPP-4 inhibitors

  18. Carbon Nanomaterials for Optical Absorber Applications

    Directory of Open Access Journals (Sweden)

    Anupama KAUL

    2011-12-01

    Full Text Available Optical absorbers based on vertically aligned multi-walled carbon nanotubes (MWCNTs, synthesized using electric-field assisted growth, are described here that show an ultra-low reflectance, 100X lower compared to the benchmark, a diffuse metal black - Au-black - from wavelength l ~ 350 nm – 2500 nm. The reflectance of the MWCNT arrays was measured to be as low as 0.02 % at 2 mm in the infra-red (IR. Growth conditions were optimized for the realization of high-areal density arrays of MWCNTs using a plasma-based chemical vapor deposition (CVD process. Such high efficiency absorbers are particularly attractive for radiometry, as well as energy harnessing applications. Optical modeling calculations were conducted that enabled a determination of the extinction coefficient in the films.

  19. Vapor diffusion synthesis of rugby-shaped CoFe{sub 2}O{sub 4}/graphene composites as absorbing materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shenli [School of Chemical Engineering and the Environment, Beijing Institute of Technology, Beijing 100081 (China); Jiao, Qingze [School of Chemical Engineering and the Environment, Beijing Institute of Technology, Beijing 100081 (China); School of Chemical Engineering and Materials Science, Beijing Institute of Technology, Zhuhai, Zhuhai 519085 (China); Hu, Ju; Li, Jingjing [School of Chemical Engineering and the Environment, Beijing Institute of Technology, Beijing 100081 (China); Zhao, Yun, E-mail: zhaoyun@bit.edu.cn [School of Chemical Engineering and the Environment, Beijing Institute of Technology, Beijing 100081 (China); Li, Hansheng; Wu, Qin [School of Chemical Engineering and the Environment, Beijing Institute of Technology, Beijing 100081 (China)

    2015-05-05

    Graphical abstract: CoFe{sub 2}O{sub 4} rugbies/graphene composites were prepared using a vapor diffusion method followed by calcination. As-synthesized rugby-like CoFe{sub 2}O{sub 4} particles were distributed on the graphene sheet. PVP played a key role for the formation of rugby-shaped morphology of CoFe{sub 2}O{sub 4} particles. A minimum reflection loss of −39.0 dB was observed at 10.9 GHz for the CoFe{sub 2}O{sub 4} rugbies/graphene composites with a thickness of 2 mm, and the effective absorption bandwidth was 4.7 GHz. The CoFe{sub 2}O{sub 4} rugbies/graphene composites exhibited better microwave absorbing performance than that of the CoFe{sub 2}O{sub 4} nanoparticles/graphene composites prepared without PVP. - Highlights: • CoFe{sub 2}O{sub 4} rugbies/graphene hybrids were synthesized using a vapor diffusion method. • PVP played a key role for the formation of CoFe{sub 2}O{sub 4} rugbies. • CoFe{sub 2}O{sub 4} rugbies/graphene composites showed excellent microwave absorbing property. - Abstract: Rugby-shaped CoFe{sub 2}O{sub 4}/graphene composites were synthesized using a vapor diffusion method in combination with calcination. The morphologies and structures of the products were characterized by field emission scanning electron microscopy, X-ray diffractometer, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. The magnetic and electromagnetic parameters were measured using a vibrating sample magnetometer and a vector network analyzer, respectively. Results show that rugby-shaped CoFe{sub 2}O{sub 4} particles are distributed on graphene sheets. A minimum reflection loss (RL) of −39.0 dB is observed at 10.9 GHz for the sample with a thickness of 2.0 mm, and the effective absorption frequency (RL < −10 dB) ranges from 9.6 to 14.3 GHz, indicating the excellent microwave absorption performance of the products. The absorbing performance of the CoFe{sub 2}O{sub 4} rugbies/graphene composites is better than that of the Co

  20. Characterization of selective solar absorber under high vacuum.

    Science.gov (United States)

    Russo, Roberto; Monti, Matteo; di Giamberardino, Francesco; Palmieri, Vittorio G

    2018-05-14

    Total absorption and emission coefficients of selective solar absorbers are measured under high vacuum conditions from room temperature up to stagnation temperature. The sample under investigation is illuminated under vacuum @1000W/m 2 and the sample temperature is recorded during heat up, equilibrium and cool down. During stagnation, the absorber temperature exceeds 300°C without concentration. Data analysis allows evaluating the solar absorptance and thermal emittance at different temperatures. These in turn are useful to predict evacuated solar panel performances at operating conditions.

  1. Self-assembly of highly efficient, broadband plasmonic absorbers for solar steam generation.

    Science.gov (United States)

    Zhou, Lin; Tan, Yingling; Ji, Dengxin; Zhu, Bin; Zhang, Pei; Xu, Jun; Gan, Qiaoqiang; Yu, Zongfu; Zhu, Jia

    2016-04-01

    The study of ideal absorbers, which can efficiently absorb light over a broad range of wavelengths, is of fundamental importance, as well as critical for many applications from solar steam generation and thermophotovoltaics to light/thermal detectors. As a result of recent advances in plasmonics, plasmonic absorbers have attracted a lot of attention. However, the performance and scalability of these absorbers, predominantly fabricated by the top-down approach, need to be further improved to enable widespread applications. We report a plasmonic absorber which can enable an average measured absorbance of ~99% across the wavelengths from 400 nm to 10 μm, the most efficient and broadband plasmonic absorber reported to date. The absorber is fabricated through self-assembly of metallic nanoparticles onto a nanoporous template by a one-step deposition process. Because of its efficient light absorption, strong field enhancement, and porous structures, which together enable not only efficient solar absorption but also significant local heating and continuous stream flow, plasmonic absorber-based solar steam generation has over 90% efficiency under solar irradiation of only 4-sun intensity (4 kW m(-2)). The pronounced light absorption effect coupled with the high-throughput self-assembly process could lead toward large-scale manufacturing of other nanophotonic structures and devices.

  2. Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rehim, F; Said, F I.A.; Abdel-Fattah, A A [National Centre for Radiation Research and Technology, Atomic Energy Athority, P.O.Box 29 Nasr City, Cairo (Egypt)

    1996-03-01

    Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.

  3. Multiband Negative Permittivity Metamaterials and Absorbers

    Directory of Open Access Journals (Sweden)

    Yiran Tian

    2013-01-01

    Full Text Available Design and characteristics of multiband negative permittivity metamaterial and its absorber configuration are presented in this paper. The proposed multiband metamaterial is composed of a novel multibranch resonator which can possess four electric resonance frequencies. It is shown that, by controlling the length of the main branches of such resonator, the resonant frequencies and corresponding absorbing bands of metamaterial absorber can be shifted in a large frequency band.

  4. Structural and optical properties of Cu2ZnSnS4 thin film absorbers from ZnS and Cu3SnS4 nanoparticle precursors

    International Nuclear Information System (INIS)

    Lin, Xianzhong; Kavalakkatt, Jaison; Kornhuber, Kai; Levcenko, Sergiu; Lux-Steiner, Martha Ch.; Ennaoui, Ahmed

    2013-01-01

    Cu 2 ZnSnS 4 (CZTS) has been considered as an alternative absorber layer to Cu(In,Ga)Se 2 due to its earth abundant and environmentally friendly constituents, optimal direct band gap of 1.4–1.6 eV and high absorption coefficient in the visible range. In this work, we propose a solution-based chemical route for the preparation of CZTS thin film absorbers by spin coating of the precursor inks composed of Cu 3 SnS 4 and ZnS NPs and annealing in Ar/H 2 S atmosphere. X-ray diffraction and Raman spectroscopy were used to characterize the structural properties. The chemical composition was determined by energy dispersive X-ray spectroscopy. Optical properties of the CZTS thin film absorbers were studied by transmission, reflection and photoluminescence spectroscopy

  5. Study the Characterization of Spectral Absorbance on Irradiated Milk Protein

    Science.gov (United States)

    Fohely, F.; Suardi, N.

    2018-04-01

    The milk has been adopted as a structural nature food for a long era since it is containing most of the growth factors, protective agents, and enzymes needed for the body. a few attempts have been conducted to treat the dairy products especially raw milk by the means of ionizing radiation. as its production has been an expanding industry for many years due to the high demands from the consumers worldwide, there is still some doubt about preserving these products by irradiation. In this work, a preliminary effort to describe the influences of ionizing radiation on raw milk’s protein will be devoted to measuring the spectral absorbance of the total protein (after subjected to varied radiation doses) by UV-VIS-NIR spectroscopy analysis. The absorbance spectrum then analyzed based on absorbance spectra of organic compounds. A comparison is made between the effects of different radiation doses to estimate the influence in milk’s structure.

  6. Catastrophic Outcomes in Free Tissue Transfer: A Six-Year Review of the NSQIP Database

    Directory of Open Access Journals (Sweden)

    David W. Grant

    2014-01-01

    Full Text Available Background. No studies report robust data on the national incidence and risk factors associated with catastrophic medical outcomes following free tissue transfer. Methods. The American College of Surgeons (ACS multicenter, prospective National Surgical Quality Improvement Program (NSQIP database was used to identify patients who underwent free tissue transfer between 2006 and 2011. Multivariable logistic regression was used for statistical analysis. Results. Over the 6-year study period 2,349 patients in the NSQIP database underwent a free tissue transfer procedure. One hundred and twenty-two patients had at least one catastrophic medical outcome (5.2%. These 122 patients had 151 catastrophic medical outcomes, including 93 postoperative respiratory failure events (4.0%, 14 pulmonary emboli (0.6%, 13 septic shock events (0.5%, 12 myocardial infarctions (0.5%, 6 cardiac arrests (0.3%, 4 strokes (0.2%, 1 coma (0.0%, and 8 deaths (0.3%. Total length of hospital stay was on average 14.7 days longer for patients who suffered a catastrophic medical complication (P<0.001. Independent risk factors were identified. Conclusions. Free tissue transfer is a proven and safe technique. Catastrophic medical complications were infrequent but added significantly to length of hospital stay and patient morbidity.

  7. Socioeconomic position and ten-year survival and virologic outcomes in a Ugandan HIV cohort receiving antiretroviral therapy.

    Directory of Open Access Journals (Sweden)

    Andrew G Flynn

    Full Text Available Lifelong ART is essential to reducing HIV mortality and ending the epidemic, however the interplay between socioeconomic position and long-term outcomes of HIV-infected persons receiving antiretroviral therapy (ART in sub-Saharan Africa is unknown. Furthering the understanding of factors related to long-term ART outcomes in this important region will aid the successful scale-up of ART programs. We enrolled 559 HIV-infected Ugandan adults starting ART in 2004-2005 at the Infectious Diseases Institute in Kampala, Uganda and followed them for 10 years. We documented baseline employment status, regular household income, education level, housing description, physical ability, and CD4 count. Viral load was measured every six months. Proportional hazard regression tested for associations between baseline characteristics and 1 mortality, 2 virologic failure, and 3 mortality or virologic failure as a composite outcome. Over ten years 23% (n = 127 of participants died, 6% (n = 31 were lost-to-follow-up and 23% (107/472 experienced virologic treatment failure. In Kaplan-Meier analysis we observed an association between employment and mortality, with the highest cumulative probability of death occurring in unemployed individuals. In univariate analysis unemployment and disease severity were associated with mortality, but in multivariable analysis the only association with mortality was disease severity. We observed an association between higher household income and an increased incidence of both virologic failure and the combined outcome, and an association between self-employment and lower incidence of virologic failure and the combined outcome when compared to unemployment. Formal education level and housing status were unrelated to outcomes. It is feasible to achieve good ten-year survival, retention-in-care, and viral suppression in a socioeconomically diverse population in a resource-limited setting. Unemployment appears to be related to adverse 10

  8. Absorber materials in CANDU PHWR's

    International Nuclear Information System (INIS)

    Price, E.G.; Boss, C.R.; Novak, W.Z.; Fong, R.W.L.

    1995-03-01

    In a CANDU reactor the fuel channels are arranged on a square lattice in a calandria filled with heavy water moderator. This arrangement allows five types of tubular neutron absorber devices to be located in a relatively benign environment of low pressure, low temperature heavy water between neighbouring rows of columns of fuel channels. This paper will describe the roles of the devices and outline the design requirements of the absorber component from a reactor physics viewpoint. Nuclear heating and activation problems associated with the different absorbers will be briefly discussed. The design and manufacture of the devices will be also discussed. The control rod absorbers and shut off materials are cadmium and stainless steel. In the tubular arrangement, the cadmium is sandwiched between stainless steel tubes. This type of device has functioned well, but there is now concern over the availability and expense of cadmium which is used in two types of CANDU control devices. There are also concerns about the toxicity of cadmium during the fabrication of the absorbers. These concerns are prompting AECL to study alternatives. To minimize design changes, pure boron-10 alloyed in stainless steel is a favoured option. Work is underway to confirm the suitability of the boron-loaded steel and identify other encapsulated absorber materials for practical application. Because the reactivity devices or their guide tubes span the calandria vessel, the long slender components must be sufficiently rigid to resist operational vibration and also be seismically stable. Some of these components are made of Zircaloy to minimize neutron absorption. Slow irradiation growth and creep can reduce the spring tension, and periodic adjustments to the springs are required. Experience with the control absorber devices has generally been good. In one instance liquid zone controllers had a problem of vibration induced fretting but a designed back-fit resolved the problem. (author). 3 refs., 1

  9. Microwave Absorbent Packaging Material from Composites Chitosan-Polyvinyl Alcohol Polymer

    Directory of Open Access Journals (Sweden)

    Bambang - Riyanto

    2014-11-01

    Full Text Available Microwave absorbent packaging materials currently tend to biomaterial. Chitosan is a dielectric biomaterial with polycationic properties. The aim of this study was to analyze characteristics of microwave absorbing packaging material made from composite chitosan-polyvinyl alcohol (PVA polymer. The ability of the packaging material to absorb microwave was determined by reflection loss measurement. Formed packaging prototype resembles as a thin transparent yellowish plastic with thickness (0.11-0.22 mm and the tensile strength (106.33±2.82-143.00±2.59 kPa. SEM analysis showed homogenous structure characterized by interaction between chitosan and PVA. Optimum absorption value was obtained from chitosan concentration of 1%, with average value of reflection loss was (-31.9289±4.0094 dB.Keywords: chitosan, material packaging, microwave, reflection loss

  10. Microwave Absorbent Packaging Material from Composites Chitosan-Polyvinyl Alcohol Polymer

    Directory of Open Access Journals (Sweden)

    Bambang - Riyanto

    2015-07-01

    Full Text Available Microwave absorbent packaging materials currently tend to biomaterial. Chitosan is a dielectric biomaterial with polycationic properties. The aim of this study was to analyze characteristics of microwave absorbing packaging material made from composite chitosan-polyvinyl alcohol (PVA polymer. The ability of the packaging material to absorb microwave was determined by reflection loss measurement. Formed packaging prototype resembles as a thin transparent yellowish plastic with thickness (0.11-0.22 mm and the tensile strength (106.33±2.82-143.00±2.59 kPa. SEM analysis showed homogenous structure characterized by interaction between chitosan and PVA. Optimum absorption value was obtained from chitosan concentration of 1%, with average value of reflection loss was (-31.9289±4.0094 dB.Keywords: chitosan, material packaging, microwave, reflection loss

  11. Sustained favorable long-term outcome in the treatment of schizophrenia: a 3-year prospective observational study

    Directory of Open Access Journals (Sweden)

    Ascher-Svanum Haya

    2011-08-01

    Full Text Available Abstract Background This study of chronically ill patients with schizophrenia aimed to identify patients who achieve sustained favorable long-term outcome - when the outcome incorporates severity of symptoms, level of functioning, and use of acute care services - and to identify the best baseline predictors of achieving this sustained favorable long-term outcome. Methods Using data from the United States Schizophrenia Care and Assessment Program (US-SCAP (N = 2327, a large 3-year prospective, multisite, observational study of individuals treated for schizophrenia in the US, a hierarchical cluster analysis was performed to group patients based upon baseline symptom severity. Symptom severity was assessed using the Positive and Negative Syndrome Scale (PANSS scores, level of functioning, and use of acute care services. Level of functioning reflected patient-reported productivity and clinician-rated occupational role functioning. Use of acute care services reflected self-reported psychiatric hospitalization and emergency service use. Change of health state was determined over the 3-year period. A patient was classified as having a sustained favorable long-term outcome if their health state values had the closest distance to the defined "best baseline cluster" at each point over the length of the study. Stepwise logistic regression was used to determine baseline predictors of sustained favorable long-term outcome. Results At baseline, 5 distinct health state clusters were identified, ranging from "best" to "worst." Of 1635 patients with sufficient data, only 157 (10% experienced sustained favorable long-term outcome during the 2-years postbaseline. The baseline predictors associated with sustained favorable long-term outcome included better quality of life, more daily activities, patient-reported clearer thinking from medication, better global functioning, being employed, not being a victim of a crime, not having received individual therapy, and not

  12. TPX/TFTR Neutral Beam energy absorbers

    International Nuclear Information System (INIS)

    Dahlgren, F.; Wright, K.; Kamperschroer, J.; Grisham, L.; Lontai, L.; Peters, C.; VonHalle, A.

    1993-01-01

    The present beam energy absorbing surfaces on the TFTR Neutral Beams such as Ion Dumps, Calorimeters, beam defining apertures, and scrapers, are simple water cooled copper plates which wee designed to absorb (via their thermal inertia) the incident beam power for two seconds with a five minute coal down interval between pulses. These components are not capable of absorbing the anticipated beam power loading for 1000 second TPX pulses and will have to be replaced with an actively cooled design. While several actively cooled energy absorbing designs were considered,, the hypervapotron elements currently being used on the JET beamlines were chosen due to their lower cooling water demands and reliable performance on JET

  13. Two-dimensional QR-coded metamaterial absorber

    Science.gov (United States)

    Sui, Sai; Ma, Hua; Wang, Jiafu; Pang, Yongqiang; Zhang, Jieqiu; Qu, Shaobo

    2016-01-01

    In this paper, the design of metamaterial absorbers is proposed based on QR coding and topology optimization. Such absorbers look like QR codes and can be recognized by decoding softwares as well as mobile phones. To verify the design, two lightweight wideband absorbers are designed, which can achieve wideband absorption above 90 % in 6.68-19.30 and 7.00-19.70 GHz, respectively. More importantly, polarization-independent absorption over 90 % can be maintained under incident angle within 55°. The QR code absorber not only can achieve wideband absorption, but also can carry information such as texts and Web sites. They are of important values in applications such identification and electromagnetic protection.

  14. Outcome of bone mineral density in anorexia nervosa patients 11.7 years after first admission.

    Science.gov (United States)

    Herzog, W; Minne, H; Deter, C; Leidig, G; Schellberg, D; Wüster, C; Gronwald, R; Sarembe, E; Kröger, F; Bergmann, G

    1993-05-01

    Osteopenia is a typical finding in patients suffering from anorexia nervosa. Unfortunately, available longitudinal studies are limited by a relatively short follow-up period. Therefore cross-sectional long-term followup studies may help to determine both the outcome of this bone lesion and variables that influence its subsequent development. Of an initial 66 consecutive patients with anorexia nervosa, 51 (77.3%) could be further evaluated. After an average of 11.7 years following first admission, cross-sectional measurements of lumbar and proximal radial bone mineral density (BMD) were performed. The ability to predict BMD using variables obtained from anamnestic and clinical data was then determined by multiple-regression analysis. The BMD of both radial and lumbar bone in anorexic patients with poor disease outcome (as defined by the Morgan-Russell general outcome categories) deviated by -2.18 and -1.73 SD (Z score), respectively. In patients with a good disease outcome lumbar BMD was significantly less reduced compared with radial BMD (-0.26 versus -0.68 SD). Variables reflecting estrogen deficiency and nutritional status in the course of the disease, that is, relative estrogen exposure (for lumbar BMD) and years of anorexia nervosa (for radial BMD), allowed the best prediction of BMD. A marked reduction in cortical and trabecular BMD in anorexic patients with poor disease outcome suggests a higher risk of fractures in these patients. Furthermore, the finding of a persistently reduced cortical and a slightly reduced trabecular BMD, even in patients with good disease outcome, suggests that a recovery of trabecular BMD might be possible, at least in part. Recovery of cortical bone, if possible at all, seems to proceed more slowly.

  15. Origami-inspired metamaterial absorbers for improving the larger-incident angle absorption

    International Nuclear Information System (INIS)

    Shen, Yang; Pang, Yongqiang; Wang, Jiafu; Ma, Hua; Pei, Zhibin; Qu, Shaobo

    2015-01-01

    When a folded resistive patch array stands up on a metallic plane, it can exhibit more outstanding absorption performance. Our theoretical investigations and simulations demonstrated that the folded resistive patch arrays can enhance the absorption bandwidth progressively with the increase of the incident angle for the oblique transverse magnetic incidence, which is contrary to the conventional resistive frequency selective surface absorber. On illumination, we achieved a 3D structure metamaterial absorber with the folded resistive patches. The proposed absorber is obtained from the inspiration of the origami, and it has broadband and lager-incident angle absorption. Both the simulations and the measurements indicate that the proposed absorber achieves the larger-incident angle absorption until 75° in the frequency band of 3.6–11.4 GHz. In addition, the absorber is extremely lightweight. The areal density of the fabricated sample is about 0.023 g cm −2 . Due to the broadband and lager-incident angle absorption, it is expected that the absorbers may find potential applications such as stealth technologies and electromagnetic interference. (paper)

  16. EUV multilayer defect compensation (MDC) by absorber pattern modification: from theory to wafer validation

    Science.gov (United States)

    Pang, Linyong; Hu, Peter; Satake, Masaki; Tolani, Vikram; Peng, Danping; Li, Ying; Chen, Dongxue

    2011-11-01

    According to the ITRS roadmap, mask defects are among the top technical challenges to introduce extreme ultraviolet (EUV) lithography into production. Making a multilayer defect-free extreme ultraviolet (EUV) blank is not possible today, and is unlikely to happen in the next few years. This means that EUV must work with multilayer defects present on the mask. The method proposed by Luminescent is to compensate effects of multilayer defects on images by modifying the absorber patterns. The effect of a multilayer defect is to distort the images of adjacent absorber patterns. Although the defect cannot be repaired, the images may be restored to their desired targets by changing the absorber patterns. This method was first introduced in our paper at BACUS 2010, which described a simple pixel-based compensation algorithm using a fast multilayer model. The fast model made it possible to complete the compensation calculations in seconds, instead of days or weeks required for rigorous Finite Domain Time Difference (FDTD) simulations. Our SPIE 2011 paper introduced an advanced compensation algorithm using the Level Set Method for 2D absorber patterns. In this paper the method is extended to consider process window, and allow repair tool constraints, such as permitting etching but not deposition. The multilayer defect growth model is also enhanced so that the multilayer defect can be "inverted", or recovered from the top layer profile using a calibrated model.

  17. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  18. Potential of HfN, ZrN, and TiH as hot carrier absorber and Al2O3/Ge quantum well/Al2O3 and Al2O3/PbS quantum dots/Al2O3 as energy selective contacts

    Science.gov (United States)

    Shrestha, Santosh; Chung, Simon; Liao, Yuanxun; Wang, Pei; Cao, Wenkai; Wen, Xiaoming; Gupta, Neeti; Conibeer, Gavin

    2017-08-01

    The hot carrier (HC) solar cell is one of the most promising advanced photovoltaic concepts. It aims to minimise two major losses in single junction solar cells due to sub-band gap loss and thermalisation of above band gap photons by using a small bandgap absorber, and, importantly, collecting the photo-generated carriers before they thermalise. In this paper we will present recent development of the two critical components of the HC solar cell, i.e., the absorber and energy selective contacts (ESCs). For absorber, fabrication and carrier cooling rates in potential bulk materials — hafnium nitride, zirconium nitride, and titanium hydride are presented. Results of ESCs employing double barrier resonant tunneling structures Al2O3/Ge quantum well (QW)/Al2O3 and Al2O3/PbS quantum dots (QDs)/Al2O3 are also presented. These results are expected to guide further development of practical HC solar cell devices.

  19. The Ahmed Versus Baerveldt Study: Five-Year Treatment Outcomes.

    Science.gov (United States)

    Christakis, Panos G; Kalenak, Jeffrey W; Tsai, James C; Zurakowski, David; Kammer, Jeffrey A; Harasymowycz, Paul J; Mura, Juan J; Cantor, Louis B; Ahmed, Iqbal I K

    2016-10-01

    To compare 2 frequently used aqueous shunts for the treatment of glaucoma. International, multicenter, randomized trial. Patients aged 18 years or older with uncontrolled glaucoma despite maximum tolerated medical therapy, many of whom had failed or were at high risk of failing trabeculectomy. Eligible patients were randomized to receive an Ahmed-FP7 valve implant (New World Medical, Inc, Rancho Cucamonga, CA) or a Baerveldt-350 implant (Abbott Medical Optics, Inc, Santa Ana, CA) using a standardized surgical technique. The primary outcome was failure, defined as intraocular pressure (IOP) outside the target range (5-18 mmHg) or reduced glaucoma surgery. Secondary outcomes measures included IOP, medication use, visual acuity, complications, and interventions. A total of 238 patients were randomized; 124 received the Ahmed-FP7 implant, and 114 received the Baerveldt-350 implant. Baseline characteristics were similar between groups. Mean preoperative IOP was 31.4±10.8 mmHg on 3.1±1.0 glaucoma medications. At 5 years, the cumulative failure rate was 53% in the Ahmed group and 40% in the Baerveldt group (P = 0.04). The main reason for failure in both groups was high IOP, and the cumulative de novo glaucoma reoperation rate was 18% in the Ahmed group and 11% in the Baerveldt group (P = 0.22). Hypotony resulted in failure in 5 patients (4%) in the Baerveldt group compared with none in the Ahmed group (P = 0.02). Mean IOP was 16.6±5.9 mmHg in the Ahmed group (47% reduction) and 13.6±5.0 mmHg in the Baerveldt group (57% reduction, P = 0.001). Mean medication use was 1.8±1.5 mmHg in the Ahmed group (44% reduction) and 1.2±1.3 mmHg in the Baerveldt group (61% reduction, P = 0.03). The 2 groups had similar complication rates (Ahmed 63%, Baerveldt 69%) and intervention rates (Ahmed 41%, Baerveldt 41%). Most complications were transient, and most interventions were slit-lamp procedures. Both implants were effective in reducing IOP and the need for glaucoma

  20. Conceptual basis for calculations of absorbed-dose distributions

    International Nuclear Information System (INIS)

    Sinclair, W.K.; Rossi, H.H.; Alsmiller, R.G.; Berger, M.J.; Kellerer, A.M.; Roesch, W.C.; Spencer, L.V.; Zaider, M.A.

    1991-01-01

    The effects of radiation on matter are initiated by processes in which atoms and molecules of the medium are ionized or excited. Over a wide range of conditions, it is an excellent approximation to assume that the average number of ionizations and excitations is proportional to the amount of energy imparted to the medium by ionizing radiation in the volume of interest. The absorbed dose, that is, the average amount of energy imparted to the medium per unit mass, is therefore of central importance for the production of radiation effects, and the calculation of absorbed-dose distributions in irradiated media is the focus of interest of the present report. It should be pointed out, however, that even though absorbed dose is useful as an index relating absorbed energy to radiation effects, it is almost never sufficient; it may have to be supplemented by other information, such as the distributions of the amounts of energy imparted to small sites, the correlation of the amounts of energy imparted to adjacent sites, and so on. Such quantities are termed stochastic quantities. Unless otherwise stated, all quantities considered in this report are non-stochastic. 266 refs., 11 figs., 2 tabs

  1. Measurements of light absorbing particulates on the glaciers in the Cordillera Blanca, Peru

    Science.gov (United States)

    Schmitt, C. G.; All, J. D.; Schwarz, J. P.; Arnott, W. P.; Cole, R. J.; Lapham, E.; Celestian, A.

    2014-10-01

    Glaciers in the tropical Andes have been rapidly losing mass since the 1970s. In addition to the documented increase in air temperature, increases in light absorbing particulates deposited on glaciers could be contributing to the observed glacier loss. Here we report on measurements of light absorbing particulates sampled from glaciers during three surveys in the Cordillera Blanca in Peru. During three research expeditions in the dry seasons (May-August) of 2011, 2012 and 2013, two hundred and forty snow samples were collected from fifteen mountain peaks over altitudes ranging from 4800 to nearly 6800 m. Several mountains were sampled each of the three expeditions and some mountains were sampled multiple times during the same expedition. Collected snow samples were melted and filtered in the field then later analyzed using the Light Absorption Heating Method (LAHM), a new technique that measures the ability of particulates on filters to absorb visible light. LAHM results have been calibrated using filters with known amounts of fullerene soot, a common industrial surrogate for black carbon (BC). As sample filters often contain dust in addition to BC, results are presented in terms of effective Black Carbon (eBC). During the 2013 survey, snow samples were collected and kept frozen for analysis with a Single Particle Soot Photometer (SP2). Calculated eBC mass from the filter analysis and the SP2 refractory Black Carbon (rBC) results were well correlated (r2 = 0.92). These results indicate that a substantial portion of the light absorbing particulates in the more polluted areas were likely BC. The three years of data show that glaciers in the Cordillera Blanca Mountains close to human population centers have substantially higher levels of eBC (as high as 70 ng g-1) than remote glaciers (as low as 2.0 ng g-1 eBC), indicating that population centers can influence local glaciers by sourcing BC.

  2. Radiation Synthesis and Characterization of Natural and Natural-Synthetic Hybrid Super Absorbent Polymers for Agricultural Applications. Chapter 19

    Energy Technology Data Exchange (ETDEWEB)

    Şen, M.; Hayrabolulu, H.; Güven, O. [Hacettepe University Department of Chemistry, Beytepe, Ankara (Turkey)

    2014-07-15

    The experimental studies carried out in Hacettepe University, Laboratories of Radiation and Polymers Science (LRPS) in the past ten years, which focused mainly on the synthesis of synthetic and natural-synthetic super absorbent polymers in various irradiation conditions, are summarized in the first part of the presentation. Studies conducted on the following areas: (1) the controlled release of fertilizers and herbicides and the effect of the natural polymer type, (2) the neutralization degree of poly(acrylic acid), (3) the temperature and pressure on the swelling kinetics, and (4) the maximum water absorption capacity of the potential soil conditional hydrogels, were explained. The results were then compared with those obtained from commercial super absorbent polymers prepared through conventional techniques. In the third part of the presentation, basic and advanced techniques in the characterization of the network structure of super water absorbents were presented. (author)

  3. Investigation of a Shock Absorber for Safeguard of Fuel Assemblies Failure

    International Nuclear Information System (INIS)

    Karalevicius, Renatas; Dundulis, Gintautas; Rimkevicius, Sigitas; Uspuras, Eugenijus

    2006-01-01

    The Ignalina NPP has two reactors. The Unit 1 was shut down, therefore the special equipment was designed for transportation of the fuel from Unit 1 to Unit 2. The fuel-loaded basket can drop during transportation. The special shock absorber was designed in order to avoid failure of fuel assemblies during transportation. In case of drop of fuel loaded basket, the failure of fuel assemblies can occur. This shock absorber was studied by scaled experiments at Lithuanian Energy Institute. Static and dynamic investigations of shock absorber are presented in this paper, including dependency of axial force versus axial compression. The finite element codes BRIGADE/Plus and ABAQUS/Explicit were used for analysis. Static simulation was used to optimize the dimensions of shock absorber. Dynamic analysis shows that shock absorber is capable to withstand the dynamic load for successful force suppression function in case of an accident. (authors)

  4. Joint unloading implant modifies subchondral bone trabecular structure in medial knee osteoarthritis: 2-year outcomes of a pilot study using fractal signature analysis

    Directory of Open Access Journals (Sweden)

    Miller LE

    2015-01-01

    Full Text Available Larry E Miller,1,2 Miki Sode,3 Thomas Fuerst,3 Jon E Block2 1Miller Scientific Consulting, Inc., Asheville, NC, USA; 2The Jon Block Group, San Francisco, CA, USA; 3Bioclinica, Newark, CA, USA Background: Knee osteoarthritis (OA is largely attributable to chronic excessive and aberrant joint loading. The purpose of this pilot study was to quantify radiographic changes in subchondral bone after treatment with a minimally invasive joint unloading implant (KineSpring® Knee Implant System.Methods: Nine patients with unilateral medial knee OA resistant to nonsurgical therapy were treated with the KineSpring System and followed for 2 years. Main outcomes included Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC pain, function, and stiffness subscores and independent core laboratory determinations of joint space width and fractal signature of the tibial cortex.Results: WOMAC scores, on average, improved by 92% for pain, 91% for function, and 79% for stiffness over the 2-year follow-up period. Joint space width in the medial compartment of the treated knee significantly increased from 0.9 mm at baseline to 3.1 mm at 2 years; joint space width in the medial compartment of the untreated knee was unchanged. Fractal signatures of the vertically oriented trabeculae in the medial compartment decreased by 2.8% in the treated knee and increased by 2.1% in the untreated knee over 2 years. No statistically significant fractal signature changes were observed in the horizontally oriented trabeculae in the medial compartment or in the horizontal or vertical trabeculae of the lateral compartment in the treated knee.Conclusion: Preliminary evidence suggests that the KineSpring System may modify knee OA disease progression by increasing joint space width and improving subchondral bone trabecular integrity, thereby reducing pain and improving joint function. Keywords: disease modification, KineSpring, joint space, pain, trabecular

  5. Photoelectron antibunching and absorber theory

    International Nuclear Information System (INIS)

    Pegg, D.T.

    1980-01-01

    The recently detected photoelectron antibunching effect is considered to be evidence for the quantised electromagnetic field, i.e. for the existence of photons. Direct-action quantum absorber theory, on the other hand, has been developed on the basis that the quantised field is illusory, with quantisation being required only for atoms. In this paper it is shown that photoelectron antibunching is readily explicable in terms of absorber theory and in fact is directly attributable to the quantum nature of the emitting and detecting atoms alone. The physical nature of the reduction of the wavepacket associated with the detection process is briefly discussed in terms of absorber theory. (author)

  6. [Can epidemiological factors affect the 2-year outcomes after surgery for degenerative lumbar disease in terms of quality of life, disability and post-surgical pain?].

    Science.gov (United States)

    Lozano-Álvarez, C; Pérez-Prieto, D; Saló-Bru, G; Molina, A; Lladó, A; Cáceres, E; Ramírez, M

    2014-01-01

    To evaluate the influence of epidemiological factors on the outcomes of surgery for degenerative lumbar disease in terms of quality of life, disability and chronic pain. A total of 263 patients who received surgery for degenerative lumbar disease (2005-2008) were included in the study. The epidemiological data collected were age, gender, employment status, and co-morbidity. The SF-36, Oswestry Disability Index (ODI), Core Outcomes Measures Index (COMI), and VAS score for lumbar and sciatic pain were measure before and 2 years after surgery. The correlation between epidemiological data and questionnaire results, as well as any independent prognostic factors, were assessed in the data analysis. The mean age of the patients was 54.0 years (22-86), and 131 were female (49.8%). There were 42 (16%) lost to follow-up. Statistically significant correlations (P<.05) were observed between age, gender, co-morbidity, permanent sick leave, and pre-operative pain with changes in the ODI, COMI, physical and SF-36 mental scales, and lumbar and sciatic VAS. Linear regression analysis showed permanent sick leave and age as predictive factors of disability (β=14.146; 95% CI: 9.09 - 29.58; P<.01 and β=0.334; 95% CI: 0.40 - 0.98, P<.05, respectively), and change in quality of life (β=-8.568; 95% CI: -14.88 - -2.26; p<.01 and β=-0.228, IC 95% CI: -0.40 - -0.06, P<.05, respectively). Based on our findings, age and permanent sick leave have to be considered as negative epidemiologic predictive factors of the outcome of degenerative lumbar disease surgery. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  7. Optimized reflectors for non-tracking solar collectors with tubular absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Muschaweck, Julius [Optics and Energy Consulting, Munich (Germany); Spirkl, Wolfgang [Ludwig-Maximilians Univ., Sektion Physik, Munich (Germany); Timinger, Andreas [Optics and Energy Consulting, Munich (Germany); ZAE Bayern, Solar Thermal and Biomass Dept., Munich (Germany); Benz, Nikolaus; Doerfler, Michael; Gut, Martin [ZAE Bayern, Solar Thermal and Biomass Dept., Munich (Germany); Kose, Erwin [microtherm Energietecjnik GmbH, Lods, 25 (France)

    2000-07-01

    We present an approach to find optimal reflector shapes for non-tracking solar collectors under practical constraints. We focus on cylindrical absorbers and reflectors with translational symmetry. Under idealised circumstances, edge ray reflectors are well known to be optimal. However, it is not clear how optimal reflectors should be shaped in order to obtain maximum utilisable energy for given operating temperatures under practical constraints like reflectivity less than unity, real radiation data, size limits, and gaps between the reflector and the absorber. For a prototype collector with a symmetric edge ray reflector and a tubular absorber, we derive from calorimetric measurements under outdoor conditions the optical efficiency as a function of the incidence angle. Using numerical optimisation and raytracing, we compare truncated symmetric edge ray reflectors, truncated asymmetric edge ray reflectors and free forms parametrized by Bezier splines. We find that asymmetric edge ray reflectors are optimal. For reasonable operating conditions, truncated asymmetric edge ray reflectors allow much better land use and easily adapt to a large range of roof tilt angles with marginal changes in collector construction. Except near the equator, they should increase the yearly utilisable energy per absorber tube by several percent as compared to the prototype collector with symmetric reflectors. (Author)

  8. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].

    Science.gov (United States)

    Liu, Jinliang; Li, Keyao; He, Jianning

    2011-01-01

    To study the indications, methods, and therapeutic effect of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. Between March 2007 and September 2009, 40 patients with multiple rib fractures received internal fixation with absorbable rib-connecting-pins, including 8 one-side flail chest and 1 two-side flail chest. There were 32 males and 8 females with an average age of 39.8 years (range, 25-72 years). The injury was caused by traffic accident in 32 cases, falling from height in 6 cases, and blunt hitting in 2 cases. Preoperatively, imaging data of the chest X-ray or spiral CT three-dimensional (3D) examination showed that all patients had multiple ribs fractures and displacement. The number of fractured ribs was 4-10 (median, 6), and the fracture location ranged from the 2nd to the 10th ribs. Of them, 28 cases were accompanied by hemathorax, pneumothorax or hemopneumothorax; 5 cases by thoracic organ injury; and 10 cases by other part trauma. The time from injury to hospitalization was less than 1 day in 26 cases, 1-3 days in 12 cases, and 3-6 days in 2 cases, and the time from hospitalization to operation was 3 hours to 3 days (mean, 1.2 days). The median fixation rib number was 5 (range, 3-8). The mean operative time, the time in bed, and hospitalization days were 32 minutes (range, 15-50 minutes), 4.5 days (range, 2-7 days), and 11.2 days (range, 5-18 days), respectively. All incisions healed by first intention. No pulmonary infection, pulmonary atelectasis, intrathoracic infection or other complications occurred. All cases were followed up 6-12 months (mean, 8 months). PaO2 [(86.6 +/- 2.2) mmHg (1 mm Hg = 0.133 kPa)] and SpO2 (97.2% +/- 0.6%) at 2 hours after operation were obviously improved when compared with preoperative ones (PaO2 (53.6 + 4.7) mm Hg and SpO2 (86.2% + 1.8%)], showing significant differences (t = 2.971, P = 0.005; t = 2.426, P = 0.020). The chest X-ray films or spiral CT 3D indicated that fracture of rib

  9. An omnidirectional electromagnetic absorber made of metamaterials

    International Nuclear Information System (INIS)

    Cheng Qiang; Cui Tiejun; Jiang Weixiang; Cai Bengeng

    2010-01-01

    In a recent theoretical work by Narimanov and Kildishev (2009 Appl. Phys. Lett. 95 041106) an optical omnidirectional light absorber based on metamaterials was proposed, in which theoretical analysis and numerical simulations showed that all optical waves hitting the absorber are trapped and absorbed. Here we report the first experimental demonstration of an omnidirectional electromagnetic absorber in the microwave frequency. The proposed device is composed of non-resonant and resonant metamaterial structures, which can trap and absorb electromagnetic waves coming from all directions spirally inwards without any reflections due to the local control of electromagnetic fields. It is shown that the absorption rate can reach 99 per cent in the microwave frequency. The all-directional full absorption property makes the device behave like an 'electromagnetic black body', and the wave trapping and absorbing properties simulate, to some extent, an 'electromagnetic black hole.' We expect that such a device could be used as a thermal emitting source and to harvest electromagnetic waves.

  10. Additive manufacturing of RF absorbers

    Science.gov (United States)

    Mills, Matthew S.

    The ability of additive manufacturing techniques to fabricate integrated electromagnetic absorbers tuned for specific radio frequency bands within structural composites allows for unique combinations of mechanical and electromagnetic properties. These composites and films can be used for RF shielding of sensitive electromagnetic components through in-plane and out-of-plane RF absorption. Structural composites are a common building block of many commercial platforms. These platforms may be placed in situations in which there is a need for embedded RF absorbing properties along with structural properties. Instead of adding radar absorbing treatments to the external surface of existing structures, which adds increased size, weight and cost; it could prove to be advantageous to integrate the microwave absorbing properties directly into the composite during the fabrication process. In this thesis, a method based on additive manufacturing techniques of composites structures with prescribed electromagnetic loss, within the frequency range 1 to 26GHz, is presented. This method utilizes screen printing and nScrypt micro dispensing to pattern a carbon based ink onto low loss substrates. The materials chosen for this study will be presented, and the fabrication technique that these materials went through to create RF absorbing structures will be described. The calibration methods used, the modeling of the RF structures, and the applications in which this technology can be utilized will also be presented.

  11. Schizophrenia: a five-year follow-up of patient outcome following psycho-education for caregivers.

    LENUS (Irish Health Repository)

    McWilliams, S

    2012-01-01

    There is evidence that psycho-education courses for caregivers of individuals with schizophrenia improve the short-term outcome of the condition. However, most of the outcome studies are limited to two-year follow-up.

  12. Energy Analysis of Solar Collector With perforated Absorber Plate

    Directory of Open Access Journals (Sweden)

    Ammar A. Farhan

    2017-09-01

    Full Text Available The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decreasing the perforation numbers. Maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations are 17, 15, and 12 oC, respectively. Also, it can be concluded that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % more than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves are 0.67, 0.64, and 0.56 for the solar collector with 3, 6 mm, and without perforations, respectively.

  13. Warm Absorber Diagnostics of AGN Dynamics

    Science.gov (United States)

    Kallman, Timothy

    Warm absorbers and related phenomena are observable manifestations of outflows or winds from active galactic nuclei (AGN) that have great potential value. Understanding AGN outflows is important for explaining the mass budgets of the central accreting black hole, and also for understanding feedback and the apparent co-evolution of black holes and their host galaxies. In the X-ray band warm absorbers are observed as photoelectric absorption and resonance line scattering features in the 0.5-10 keV energy band; the UV band also shows resonance line absorption. Warm absorbers are common in low luminosity AGN and they have been extensively studied observationally. They may play an important role in AGN feedback, regulating the net accretion onto the black hole and providing mechanical energy to the surroundings. However, fundamental properties of the warm absorbers are not known: What is the mechanism which drives the outflow?; what is the gas density in the flow and the geometrical distribution of the outflow?; what is the explanation for the apparent relation between warm absorbers and the surprising quasi-relativistic 'ultrafast outflows' (UFOs)? We propose a focused set of model calculations that are aimed at synthesizing observable properties of warm absorber flows and associated quantities. These will be used to explore various scenarios for warm absorber dynamics in order to answer the questions in the previous paragraph. The guiding principle will be to examine as wide a range as possible of warm absorber driving mechanisms, geometry and other properties, but with as careful consideration as possible to physical consistency. We will build on our previous work, which was a systematic campaign for testing important class of scenarios for driving the outflows. We have developed a set of tools that are unique and well suited for dynamical calculations including radiation in this context. We also have state-of-the-art tools for generating synthetic spectra, which are

  14. Drug-eluting stents with biodegradable polymer for the treatment of patients with diabetes mellitus: clinical outcome at 2 years in a large population of patients

    Directory of Open Access Journals (Sweden)

    Wiemer M

    2015-02-01

    Full Text Available Marcus Wiemer,1 Gian Battista Danzi,2 Nick West,3 Vassilios Voudris,4 René Koning,5 Stefan Hoffmann,6 Mario Lombardi,7 Josepa Mauri,8 Rade Babic,9 Fraser Witherow10On behalf of the NOBORI 2 Investigators 1Department of Cardiology, Heart and Diabetes Center North Rhine–Westphalia, Ruhr University Bochum, Bad Oeynhausen, Germany; 2Ospedale Maggiore Policlinico, Milan, Italy; 3Papworth Hospital, Cambridge, UK; 4Onassis Cardiac Surgery Center, Athens, Greece; 5Clinique Saint Hilaire, Rouen, France; 6Vivantes Netzwerk für Gesundheit GmbH, Berlin, Germany; 7Azienda Ospedaliera Villa Sofia, Palermo, Italy; 8Hospital Universitari Germans Trias i Pujol, Badalona, Spain; 9Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia; 10Dorset County Hospital, Dorchester, UK Objective: This study investigates the safety and efficacy of a third-generation drug-eluting stent (DES with biodegradable polymer in the complex patient population of diabetes mellitus (DM. Clinical trial registration: ISRCTN81649913. Background: Percutaneous coronary interventions in patients with DM are associated with a higher incidence of death, restenosis, and stent thrombosis as compared to non-diabetic patients. The use of a DES has been shown to improve outcomes in diabetic patients. Methods: Out of 3,067 patients, enrolled in 126 centers worldwide in the NOBORI 2 registry, 888 patients suffered from DM, 213 of them (14% being insulin-dependent DM (IDDM. Two years’ follow-up has been completed in this study. Results: At 1- and 2-year follow-up, 97% and 95% of the patients, respectively, were available. The reported target lesion failure (TLF rates at 1- and 2-year follow-up were 6.0% and 7.2% in the DM group, respectively, and 3.0% and 4.2% in the non-DM group, respectively (P<0.001 for both years. Inside the DM group, the TLF rates of 9.9% and 11.7% at the 1- and 2-year follow-ups, respectively, in patients with IDDM were significantly higher than the TLF rates of 4

  15. UV-visible absorbance spectroscopy as a proxy for peatland dissolved organic carbon (DOC) quantity and quality: considerations on wavelength and absorbance degradation.

    Science.gov (United States)

    Peacock, Mike; Evans, Chris D; Fenner, Nathalie; Freeman, Chris; Gough, Rachel; Jones, Timothy G; Lebron, Inma

    2014-05-01

    Absorbance in the UV or visible spectrum (UV-vis) is commonly used as a proxy for DOC concentrations in waters draining upland catchments. To determine the appropriateness of different UV-vis measurements we used surface and pore water samples from two Welsh peatlands in four different experiments: (i) an assessment of single wavelength proxies (1 nm increments between 230-800 nm) for DOC concentration demonstrated that 254 nm was more accurate than 400 nm. The highest R(2) values between absorbance and DOC concentration were generated using 263 nm for one sample set (R(2) = 0.91), and 230 nm for the other three sample sets (respective R(2) values of 0.86, 0.81, and 0.93). (ii) A comparison of different DOC concentration proxies, including single wavelength proxies, a two wavelength model, a proxy using phenolic concentration, and a proxy using the area under a UV spectrum at 250-350 nm. It was found that both a single wavelength proxy (≤263 nm) and a two wavelength model performed well for both pore water and surface water. (iii) An evaluation of the E2 : E3, E2 : E4, E4 : E6 ratios, and SUVA (absorbance at 254 nm normalised to DOC concentration) as indicators of DOC quality showed that the E4 : E6 ratio was subject to extensive variation over time, and was highly correlated between surface water and pore water, suggesting that it is a useful metric to determine temporal changes in DOC quality. (iv) A repeated weekly analysis over twelve weeks showed no consistent change in UV-vis absorbance, and therefore an inferred lack of degradation of total DOC in samples that were filtered and stored in the dark at 4 °C.

  16. Pain and Mean Absorbed Dose to the Pubic Bone After Radiotherapy Among Gynecological Cancer Survivors

    International Nuclear Information System (INIS)

    Waldenstroem, Ann-Charlotte; Olsson, Caroline; Wilderaeng, Ulrica; Dunberger, Gail; Lind, Helena; Al-Abany, Massoud; Palm, Asa; Avall-Lundqvist, Elisabeth; Johansson, Karl-Axel; Steineck, Gunnar

    2011-01-01

    Purpose: To analyze the relationship between mean absorbed dose to the pubic bone after pelvic radiotherapy for gynecological cancer and occurrence of pubic bone pain among long-term survivors. Methods and Materials: In an unselected, population-based study, we identified 823 long-term gynecological cancer survivors treated with pelvic radiotherapy during 1991-2003. For comparison, we used a non-radiation-treated control population of 478 matched women from the Swedish Population Register. Pain, intensity of pain, and functional impairment due to pain in the pubic bone were assessed with a study-specific postal questionnaire. Results: We analyzed data from 650 survivors (participation rate 79%) with median follow-up of 6.3 years (range, 2.3-15.0 years) along with 344 control women (participation rate, 72 %). Ten percent of the survivors were treated with radiotherapy; ninety percent with surgery plus radiotherapy. Brachytherapy was added in 81%. Complete treatment records were recovered for 538/650 survivors, with dose distribution data including dose-volume histograms over the pubic bone. Pubic bone pain was reported by 73 survivors (11%); 59/517 (11%) had been exposed to mean absorbed external beam doses <52.5 Gy to the pubic bone and 5/12 (42%) to mean absorbed external beam doses ≥52.5 Gy. Thirty-three survivors reported pain affecting sleep, a 13-fold increased prevalence compared with control women. Forty-nine survivors reported functional impairment measured as pain walking indoors, a 10-fold increased prevalence. Conclusions: Mean absorbed external beam dose above 52.5 Gy to the pubic bone increases the occurrence of pain in the pubic bone and may affect daily life of long-term survivors treated with radiotherapy for gynecological cancer.

  17. Muon Intensity Increase by Wedge Absorbers for Low-E Muon Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. V. [Fermilab; Stratakis, D. [Fermilab; Bradley, J. [Fermilab

    2017-09-01

    Low energy muon experiments such as mu2e and g-2 have a limited energy spread acceptance. Following techniques developed in muon cooling studies and the MICE experiment, the number of muons within the desired energy spread can be increased by the matched use of wedge absorbers. More generally, the phase space of muon beams can be manipulated by absorbers in beam transport lines. Applications with simulation results are presented.

  18. Computational design for a wide-angle cermet-based solar selective absorber for high temperature applications

    International Nuclear Information System (INIS)

    Sakurai, Atsushi; Tanikawa, Hiroya; Yamada, Makoto

    2014-01-01

    The purpose of this study is to computationally design a wide-angle cermet-based solar selective absorber for high temperature applications by using a characteristic matrix method and a genetic algorithm. The present study investigates a solar selective absorber with tungsten–silica (W–SiO 2 ) cermet. Multilayer structures of 1, 2, 3, and 4 layers and a wide range of metal volume fractions are optimized. The predicted radiative properties show good solar performance, i.e., thermal emittances, especially beyond 2 μm, are quite low, in contrast, solar absorptance levels are successfully high with wide angular range, so that solar photons are effectively absorbed and infrared radiative heat loss can be decreased. -- Highlights: • Electromagnetic simulation of radiative properties by characteristic matrix method. • Optimization for multilayered W–SiO 2 cermet-based absorber by a Genetic Algorithm. • We propose a successfully high solar performance of solar selective absorber

  19. Preparation of super absorbent by irradiation polymerization

    International Nuclear Information System (INIS)

    Hua Fengjun; Tan Chunhong; Qian Mengping

    1995-01-01

    A kind of absorbent is prepared by gamma-rays irradiated by reversed-phase suspension polymerization. Drying particles have 1400 (g/g) absorbency in de-ionic water. Effects of reactive conditions, e.g.: dose-rate, dose, monomer concentration, degree of monomer neutralization and crosslinking agents on absorbency in de-ionic water are discussed. The cause of absorbing de-ionic water by polymer is related to its network structure and ionic equilibrium in particle. Accordingly, a suit reactive condition is chosen for preparation of hydro gel spheres

  20. Frequency Tuning of Vibration Absorber Using Topology Optimization

    Science.gov (United States)

    Harel, Swapnil Subhash

    A tuned mass absorber is a system for reducing the amplitude in one oscillator by coupling it to a second oscillator. If tuned correctly, the maximum amplitude of the first oscillator in response to a periodic driver will be lowered, and much of the vibration will be 'transferred' to the second oscillator. The tuned vibration absorber (TVA) has been utilized for vibration control purposes in many sectors of Civil/Automotive/Aerospace Engineering for many decades since its inception. Time and again we come across a situation in which a vibratory system is required to run near resonance. In the past, approaches have been made to design such auxiliary spring mass tuned absorbers for the safety of the structures. This research focuses on the development and optimization of continuously tuned mass absorbers as a substitute to the discretely tuned mass absorbers (spring- mass system). After conducting the study of structural behavior, the boundary condition and frequency to which the absorber is to be tuned are determined. The Modal analysis approach is used to determine mode shapes and frequencies. The absorber is designed and optimized using the topology optimization tool, which simultaneously designs, optimizes and tunes the absorber to the desired frequency. The tuned, optimized absorber, after post processing, is attached to the target structure. The number of the absorbers are increased to amplify bandwidth and thereby upgrade the safety of structure for a wide range of frequency. The frequency response analysis is carried out using various combinations of structure and number of absorber cell.

  1. Tuning Transpiration by Interfacial Solar Absorber-Leaf Engineering.

    Science.gov (United States)

    Zhuang, Shendong; Zhou, Lin; Xu, Weichao; Xu, Ning; Hu, Xiaozhen; Li, Xiuqiang; Lv, Guangxin; Zheng, Qinghui; Zhu, Shining; Wang, Zhenlin; Zhu, Jia

    2018-02-01

    Plant transpiration, a process of water movement through a plant and its evaporation from aerial parts especially leaves, consumes a large component of the total continental precipitation (≈48%) and significantly influences global water distribution and climate. To date, various chemical and/or biological explorations have been made to tune the transpiration but with uncertain environmental risks. In recent years, interfacial solar steam/vapor generation is attracting a lot of attention for achieving high energy transfer efficiency. Various optical and thermal designs at the solar absorber-water interface for potential applications in water purification, seawater desalination, and power generation appear. In this work, the concept of interfacial solar vapor generation is extended to tunable plant transpiration by showing for the first time that the transpiration efficiency can also be enhanced or suppressed through engineering the solar absorber-leaf interface. By tuning the solar absorption of membrane in direct touch with green leaf, surface temperature of green leaf will change accordingly because of photothermal effect, thus the transpiration efficiency as well as temperature and relative humidity in the surrounding environment will be tuned. This tunable transpiration by interfacial absorber-leaf engineering can open an alternative avenue to regulate local atmospheric temperature, humidity, and eventually hydrologic cycle.

  2. Subtotal parathyroidectomy for secondary renal hyperparathyroidism: a 20-year surgical outcome study.

    Science.gov (United States)

    Konturek, Aleksander; Barczyński, Marcin; Stopa, Małgorzata; Nowak, Wojciech

    2016-11-01

    The aim of this study was to evaluate the outcomes of surgery for patients with secondary renal hyperparathyroidism (rHPT). This is a retrospective cohort study. Our institutional database was searched for eligible patients treated in 1995-2014. The inclusion criterion was initial parathyroidectomy for rHPT. Clinical and follow-up data were analyzed to estimate the cure rate (primary outcome), and morbidity (secondary outcome). The study group comprised 297 patients (154 females, age 44.5 ± 13.7 years, follow-up 24.6 ± 10.5 months), including 268 (90.2 %) patients who had underwent subtotal parathyroidectomy, and 29 (9.8 %) who had had incomplete parathyroidectomy. Intraoperative iPTH assay was utilized in 207 (69.7 %) explorations. Persistent rHPT occurred in 12/268 (4.5 %) patients after subtotal parathyroidectomy and 5/29 (17.2 %) subjects after incomplete parathyroidectomy (p = 0.005). The patients operated on with intraoperative iPTH assay had a higher cure rate than non-monitored individuals, 201/207 (97.1 %) vs. 79/90 (87.8 %), respectively (p = 0.001). In-hospital mortality occurred in 1/297 (0.3 %) patient. The hungry bone syndrome occurred in 84/268 (31.3 %) patients after subtotal parathyroidectomy and 2/29 (6.9 %) subjects after incomplete parathyroidectomy (p = 0.006). Transient recurrent laryngeal nerve paresis occurred in 14/594 (2.4 %) and permanent in 5/594 (0.8 %) nerves at risk. Subtotal parathyroidectomy is a safe and efficacious treatment for patients with rHPT. Utilization of intraoperative iPTH assay can guide surgical exploration and improve the cure rate.

  3. Feasibility study of chabazite absorber tube utilization in online absorption of released gaseous fission products and substitution of burnable absorber rods with chabazite absorber tubes in VVER-1000 reactor series

    International Nuclear Information System (INIS)

    Rahmani, Yashar

    2017-01-01

    Highlights: • Chabazite tubes are used for online removal of the released gaseous fission products. • The feasibility of using chabazite tubes instead of burnable absorber rods was studied. • A computational cycle was designed using the WIMSD5-B, CITATION-LDI2 and WERL codes. • In modeling fission gas release, the Weisman, Booth, Mason and T.S. models were used. • By this method, it is possible to increase cycle length and enhance heat transfer. - Abstract: As gaseous fission products, e.g. xenon and krypton have adverse effects such as reducing the rate of heat transfer in fuel rods and adding negative reactivity to the reactor core, the present manuscript was dedicated to development of a novel method for improving these defects. In the proposed method, chabazite absorber tubes were used for online removal of the released gaseous fission products from gaseous gap spaces. Moreover, in this research, feasibility of using chabazite absorber tubes instead of burnable absorber rods was examined. To perform the required modeling and calculations to successfully meet the mentioned objectives, a thermo-neutronic computational cycle was designed using the coupling of WIMSD5-B and CITATION-LDI2 codes in the neutronic section and the WERL code in the thermo-hydraulic calculations. In addition, in modeling the release process of gaseous fission products, the Weisman, Booth, Mason, and T.S. models were examined. It is worth mentioning that in this research, calculations and modeling procedures were based on the first cycle of Bushehr’s VVER-1000 reactor to study the feasibility of the proposed solution. The obtained results revealed that with application of the proposed method in this research, it is possible to increase cycle length, improve safety thresholds, and enhance heat transfer in the core of nuclear reactors.

  4. SXPS investigation of the Cd partial electrolyte treatment of CuInSe2 absorbers

    International Nuclear Information System (INIS)

    Hunger, R.; Schulmeyer, T.; Klein, A.; Jaegermann, W.; Lebedev, M.V.; Sakurai, K.; Niki, S.

    2005-01-01

    The chemical modification of polycrystalline CuInSe 2 absorber surfaces by the so-called Cd partial electrolyte (PE) treatment was studied by synchrotron X-ray photoelectron spectroscopy (SXPS). The Cd PE treatment was found to remove surface indium oxides and hydroxides and segregated sodium compounds. A hydroxide-terminated CdSe surface layer of one monolayer thickness is formed by the partial electrolyte treatment. The reaction mechanism is discussed as substrate site-controlled exchange reaction, where surface indium is removed and replaced by cadmium. Electronically, the Cd PE treated surface is inverted and exhibits a surface barrier which is by 0.2 eV higher than a comparable structure that was prepared by the vacuum deposition of one monolayer of CdS onto clean CuInSe 2

  5. Optical fibre temperature sensor technology and potential application in absorbed dose calorimetry

    International Nuclear Information System (INIS)

    Allen, P.D.; Hargrave, N.J.

    1992-09-01

    Optical fibre based sensors are proposed as a potential alternative to the thermistors traditionally used as temperature sensors in absorbed dose calorimetry. The development of optical fibre temperature sensor technology over the last ten years is reviewed. The potential resolution of various optical techniques is assessed with particular reference to the requirements of absorbed dose calorimetry. Attention is drawn to other issues which would require investigation before the development of practical optical fibre sensors for this purpose could occur. 192 refs., 5 tabs., 4 figs

  6. Four-year treatment outcomes of adult patients enrolled in Mozambique's rapidly expanding antiretroviral therapy program.

    Directory of Open Access Journals (Sweden)

    Andrew F Auld

    Full Text Available BACKGROUND: In Mozambique during 2004-2007 numbers of adult patients (≥15 years old enrolled on antiretroviral therapy (ART increased about 16-fold, from 60 kg, WHO stage IV (AHR 1.7; 95% CI, 1.3-2.4, reference group WHO stage I/II, lack of co-trimoxazole prescription (AHR 1.4; 95% CI, 1.0-1.8, and later calendar year of ART initiation (AHR 1.5; 95% CI, 1.2-1.8. Rates of immunologic treatment failure and regimen-switch were 14.0 and 0.6 events per 100-patient years, respectively. CONCLUSIONS: ART initiation at earlier disease stages and scale-up of co-trimoxazole among ART patients could improve outcomes. Research to determine reasons for low regimen-switch rates and increasing rates of attrition during program expansion is needed.

  7. The Ahmed versus Baerveldt study: three-year treatment outcomes.

    Science.gov (United States)

    Christakis, Panos G; Tsai, James C; Kalenak, Jeffrey W; Zurakowski, David; Cantor, Louis B; Kammer, Jeffrey A; Ahmed, Iqbal I K

    2013-11-01

    To compare 2 commonly used aqueous drainage devices for the treatment of refractory glaucoma. International, multicenter, randomized trial. Patients aged 18 years or older with uncontrolled or high-risk glaucoma refractory to maximum medical therapy, many of whom had failed trabeculoplasty and trabeculectomy. Eligible patients were randomized to an Ahmed-FP7 valve implant (New World Medical, Inc., Rancho Cucamonga, CA) or a Baerveldt-350 implant (Abbott Medical Optics, Inc., Santa Ana, CA) using a standardized surgical technique. The primary outcome was failure, defined as intraocular pressure (IOP) outside of the target range (5-18 mmHg, with ≥20% reduction from baseline) for 2 consecutive visits after 3 months, vision-threatening complications, de novo glaucoma procedures, or loss of light perception. Secondary outcome measures include IOP, medication use, visual acuity, complications, and interventions. A total of 238 patients were enrolled and randomized; 124 received the Ahmed implant and 114 received the Baerveldt implant. Baseline characteristics were similar in both groups. Half the study group had secondary glaucoma, and 37% had previously failed trabeculectomy. The mean preoperative IOP was 31.4±10.8 mmHg on 3.1±1.0 glaucoma medications. Median baseline Snellen visual acuity was 20/100. At 3 years, the cumulative probability of failure was 51% in the Ahmed group and 34% in the Baerveldt group (P = 0.03). Mean IOP was 15.7±4.8 mmHg in the Ahmed group (49% reduction) and 14.4±5.1 mmHg in the Baerveldt group (55% reduction; P = 0.09). Mean number of glaucoma medications was 1.8±1.4 in the Ahmed group (42% reduction) and 1.1±1.3 in the Baerveldt group (65% reduction; P = 0.002). There was a moderate but similar decrease in visual acuity in both groups (PAhmed, 62% Baerveldt; P = 0.12); however, the Baerveldt group had a higher rate of hypotony-related vision-threatening complications (0% Ahmed, 6% Baerveldt; P = 0.005). More interventions were

  8. Shock absorber

    International Nuclear Information System (INIS)

    Nemeth, J.D.

    1981-01-01

    A shock absorber for the support of piping and components in a nuclear power plant is described. It combines a high degree of stiffness under sudden shocks, e.g. seismic disturbances, with the ability to allow for thermal expansion without resistance when so required. (JIW)

  9. A Study on the Design of Novel Neutron Absorber Using Artificial Rare Earth Compound

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Shin, Chang Ho; Lee, Seung Hyun; Park, Jeia; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of); Kim, Soon Young [RADCORE Co., Ltd., Daejeon (Korea, Republic of); Park, Hwan Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The artificial rare earth compounds (RE{sub 2}O{sub 3}) generated by the result of the pyro-processing are radioactive wastes which have many long-live radionuclides. Due to the high and long-lived radioactivity of the article RE{sub 2}O{sub 3}, specific radiation shielding and disposal techniques are required. In this study, a simultaneous disposal method of the RE{sub 2}O{sub 3} with the spent fuels is proposed by reusing them for the neutron absorber. In this study, the neutron absorber based on artificial RE{sub 2}O{sub 3} compound was designed for the use in the spent fuel storage. The design of the storage racks for the WH 17Χ17 and PLUS7 spent fuel assemblies were designed and the criticalities were evaluated with the various RE{sub 2}O{sub 3} compositions. Also, the radioactivity and irradiation calculations were performed for the applicability and stability analyses of the neutron absorber into the spent fuel storage. The results show that the neutron absorber can sufficiently reduce the criticality under the regulation guideline. It is expected that the neutron absorber can contribute minimizing the disposal area of the radioactive wastes as well as the reducing the costs and resources for the using the other types of the neutron absorbers.

  10. 21 CFR 880.5300 - Medical absorbent fiber.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical absorbent fiber. 880.5300 Section 880.5300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5300 Medical absorbent fiber. (a) Identification. A medical absorbent fiber is a device...

  11. Scanning electron microscopical examination of the impact of laser patterning on microscopic inhomogeneities of Cu(In,Ga)(Se,S)2 absorbers produced by rapid thermal processing

    International Nuclear Information System (INIS)

    Künecke, U.; Hölzing, A.; Jost, S.; Lechner, R.; Vogt, H.; Heiß, A.; Palm, J.; Hock, R.; Wellmann, P.

    2013-01-01

    Laser scribing of the Mo back electrode is commonly applied to define the cell structure of Cu(In,Ga)(Se,S) 2 (CIGSSe) thin film solar cells. The patterning process was performed on laboratory samples using ns and ps pulse length laser processes. After structuring, CIGSSe absorbers were processed by rapid thermal processing (RTP) of stacked elemental layer precursors. Microscopic inhomogeneities were investigated on different sample positions. For samples structured with ns pulse, the absorber morphology in the laser line vicinity is different as compared to the morphology in the unstructured cell area. Scanning electron microscopy and energy-dispersive X-ray spectroscopy show significant changes in the absorber grain size and chemical composition. Close to the laser line, the typically observed Ga accumulation on the back contact is less pronounced and more Ga is incorporated closer to the surface leading to a smaller grain size. The observed changes are attributed to partial damaging of a diffusion barrier between glass and Mo induced by the ns laser process, which allows diffusion of sodium from the glass substrate into the absorber during RTP. The enhanced Ga incorporation closer to the surface is an indication for the influence of sodium on the local phase development during RTP. The damages of the diffusion barrier can be effectively prevented by the application of a ps laser scribing process. CIGSSe absorbers processed on samples structured with ps pulse length do not show the described microscopic inhomogeneities around the laser line. - Highlights: ► Scanning electron microscopy on Cu(In,Ga)(Se,S) 2 solar cell absorbers ► Laser patterning with ns laser pulse damages the sodium diffusion barrier. ► Improved laser patterning with ps laser pulse leaves diffusion barrier intact. ► Additional sodium changes phase development during absorber formation. ► Gallium content is increased at surface and decreased at backside of absorber

  12. A checkerboard selective absorber with excellent spectral selectivity

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Liu, E-mail: optyang@zju.edu.cn [Centre for Optical and Electromagnetic Research, State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310058 (China); School of Electrical, Computer, and Engineering, Arizona State University, Tempe, Arizona 85287 (United States); Mo, Lei; Chen, Tuo [Centre for Optical and Electromagnetic Research, State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310058 (China); Department of Physics, Zhejiang University, Hangzhou 310027 (China); Forsberg, Erik [Centre for Optical and Electromagnetic Research, State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310058 (China); He, Sailing [Centre for Optical and Electromagnetic Research, State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310058 (China); Department of Electromagnetic Engineering, JORCEP, Roy Institute of Technology (KTH), S-100 44 Stockholm (Sweden)

    2015-11-14

    A selective absorber with excellent spectral selectivity is proposed and analyzed. The absorber is based on a germanium (Ge) checkerboard on top of a tantalum (Ta) substrate. At wavelengths shorter than the 1.2 μm cutoff, a very high absorption is achieved due to strong cavity resonances in the Ge nanosquares, and their interactions with adjacent nanocavities and the bottom Ta substrate. At longer wavelengths, absorption is greatly suppressed due to destructive interference between the transparent checkerboard layer and the highly reflective Ta substrate. To better describe the superior selectivity of our configuration, a new figure of merit (FOM) is introduced. We observe a FOM value of 0.88 compared to 0.69 for its planar counterpart. We also conduct a thermal analysis to verify the excellent selectivity of our absorber. A high temperature can be achieved and maintained, promising good potential for applications in solar thermophotovoltaic systems.

  13. De novo status epilepticus is associated with adverse outcome: An 11-year retrospective study in Hong Kong.

    Science.gov (United States)

    Lui, Hoi Ki Kate; Hui, Kwok Fai; Fong, Wing Chi; Ip, Chun Tak; Lui, Hiu Tung Colin

    2016-08-01

    To identify predictors of poor clinical outcome in patients presenting to the intensive care units with status epilepticus (SE), in particular for patients presenting with de novo status epileptics. A retrospective review was performed on patients admitted to the intensive care units with status epilepticus in two hospitals in Hong Kong over an 11-year period from 2003 to 2013. A total of 87 SE cases were analyzed. The mean age of patients was 49.3 years (SD 14.9 years). Eighteen subjects (20.7%) had breakthrough seizure, which was the most common etiology for the status epilepticus episodes. Seventy-eight subjects (89.7%) had convulsive status epilepticus (CSE) and 9 subjects (10.3%) had non-convulsive status epilepticus (NCSE) on presentation. The 30-day mortality rate of all subjects was 18.4%. Non-convulsive status epilepticus was more common in patients with de novo status epilepticus when compared to those with existing history of epilepsy (15.5% Vs. 0%, p=0.03). Patients with de novo status epilepticus were older (52 Vs 43, p=0.009). De novo status epilepticus was associated with longer status duration (median 2.5 days, IQR 5 days), longer ICU stay (median 7.5 days, IQR 9 days) and poorer outcome (OR 4.15, 95% CI 1.53-11.2). For patients presenting to intensive care units with status epilepticus, those with de novo status epileptics were older and were more likely to develop non-convulsive status epilepticus. De novo status epilepticus was associated with poorer outcome. Continuous EEG monitoring would help identifying NCSE and potentially help improving clinical outcomes. Copyright © 2016 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  14. Bystander Efforts and 1-Year Outcomes in Out-of-Hospital Cardiac Arrest.

    Science.gov (United States)

    Kragholm, Kristian; Wissenberg, Mads; Mortensen, Rikke N; Hansen, Steen M; Malta Hansen, Carolina; Thorsteinsson, Kristinn; Rajan, Shahzleen; Lippert, Freddy; Folke, Fredrik; Gislason, Gunnar; Køber, Lars; Fonager, Kirsten; Jensen, Svend E; Gerds, Thomas A; Torp-Pedersen, Christian; Rasmussen, Bodil S

    2017-05-04

    The effect of bystander interventions on long-term functional outcomes among survivors of out-of-hospital cardiac arrest has not been extensively studied. We linked nationwide data on out-of-hospital cardiac arrests in Denmark to functional outcome data and reported the 1-year risks of anoxic brain damage or nursing home admission and of death from any cause among patients who survived to day 30 after an out-of-hospital cardiac arrest. We analyzed risks according to whether bystander cardiopulmonary resuscitation (CPR) or defibrillation was performed and evaluated temporal changes in bystander interventions and outcomes. Among the 2855 patients who were 30-day survivors of an out-of-hospital cardiac arrest during the period from 2001 through 2012, a total of 10.5% had brain damage or were admitted to a nursing home and 9.7% died during the 1-year follow-up period. During the study period, among the 2084 patients who had cardiac arrests that were not witnessed by emergency medical services (EMS) personnel, the rate of bystander CPR increased from 66.7% to 80.6% (Pbystander defibrillation increased from 2.1% to 16.8% (Pbystander CPR was associated with a risk of brain damage or nursing home admission that was significantly lower than that associated with no bystander resuscitation (hazard ratio, 0.62; 95% confidence interval [CI], 0.47 to 0.82), as well as a lower risk of death from any cause (hazard ratio, 0.70; 95% CI, 0.50 to 0.99) and a lower risk of the composite end point of brain damage, nursing home admission, or death (hazard ratio, 0.67; 95% CI, 0.53 to 0.84). The risks of these outcomes were even lower among patients who received bystander defibrillation as compared with no bystander resuscitation. In our study, we found that bystander CPR and defibrillation were associated with risks of brain damage or nursing home admission and of death from any cause that were significantly lower than those associated with no bystander resuscitation. (Funded by Tryg

  15. Outcomes and Complications of the Midline Anterior Approach 3 Years after Lumbar Spine Surgery

    Directory of Open Access Journals (Sweden)

    Charla R. Fischer

    2014-01-01

    Full Text Available Objective. The purpose of this study was to evaluate a new questionnaire to assess outcomes related to the midline anterior lumbar approach and to identify risk factors for negative patient responses. Methods. A retrospective review of 58 patients who underwent anterior lumbar surgery at a single institution for either degenerative disc disease or spondylolisthesis in 2009 was performed. The outcome measures included our newly developed Anterior Lumbar Surgery Questionnaire (ALSQ, ODI, and EQ-5D. Results. There were 58 patients available for followup, 27 women and 31 men. The average age at surgery was 50.8 years, with an average followup of 2.92 years. The average change in ODI was 34.94 (22.7 and EQ-5D was 0.28 (0.29. The rate of complications with the anterior approach was 10.3% and there was one male patient (3.2% with retrograde ejaculation. Determination of the effectiveness of the new ALSQ revealed that it significantly correlated to the EQ-5D and ODI (P<0.05. Smoking was associated with a negative response on thirteen questions. BMP use was not associated with a negative response on any sexual function questions. Conclusions. Our new Anterior Lumbar Surgery Questionnaire determines patient perceived complications related to the midline anterior lumbar surgical approach.

  16. Patients ≥ 75 years with acute coronary syndrome but without critical epicardial coronary disease: prevalence, characteristics, and outcome

    Science.gov (United States)

    Wong, Vincent; Farah, Ahmed; von Korn, Hubertus; Memisevic, Nedim; Richter, Stefan; Tukhiashvili, Ketevan; Lauer, Bernward; Ohlow, Marc-Alexander

    2015-01-01

    Objective Absence of significant epicardial coronary artery disease (CAD) in patients with acute onset of chest pain and elevation of myocardial necrosis markers is occasionally observed. The aim of this study was to analyse the clinical characteristics and outcome of such patients with advanced age. Methods We retrospectively analysed 4,311 patients with acute onset of chest pain plus necrosis marker elevation. Two hundred and seventy two patients without CAD on angiogram (6.3%) were identified. Out of them, 50 (1.2%) patients ≥ 75 years (Group I) were compared with (1) 222 acute coronary syndrome (ACS) patients without CAD on angiogram < 75 years (Group II), and (2) 610 consecutive patients ≥ 75 years with Non-ST-elevation Myocardial Infarction (NSTEMI) undergoing percutaneous coronary intervention (Group III). Results Group I compared to Group III patients made up for more females (64.0% vs. 49.2%; P < 0.0001), and had more severe anginal symptoms on presentation [Canadian Cardiovascular Society (CCS) class I/II, 26.0% vs. 49.8%; P = 0.02]. Group I patients also had lower troponin levels (0.62 ± 0.8 ng/mL vs. 27 ± 74 ng/mL; P < 0.02), lower leukocyte count (9.4 ± 3.13 × 109 vs. 12 ± 5.1 × 109; P = 0.001) and better preserved left ventricular function (56.7% ± 14.3% vs. 45% ± 11%; P < 0.0001). Event-free survival (cardiac death, myocardial infarction, recurrent angina, and re-hospitalisation) was more frequent in Group I and II patients compared to Group III patients (64.9%, 66.7%, and 41.6%, respectively; P < 0.0001). Conclusions ACS in patients ≥ 75 years without CAD is very infrequent, associated with a (1) similar outcome compared to ACS patients < 75 years without CAD, and (2) significant better outcome compared to NSTEMI patients ≥ 75 years. PMID:25678899

  17. Skin Health Connected to the Use of Absorbent Hygiene Products: A Review.

    Science.gov (United States)

    Bender, Johanna Karlsson; Faergemann, Jan; Sköld, Maria

    2017-09-01

    Over the past 50 years, absorbent hygiene products such as baby diapers and incontinence products have become essential features of modern day life. Through innovation and enhanced technology, their design, composition and performance have been dramatically upgraded from their early forms, and they have transformed the lives of millions of people, improving their quality of life. Skin health related to the use of absorbent hygiene products has accordingly also greatly improved. Still, the wearing of absorbent hygiene products will affect the skin, and for some users the changes in microclimate, mechanical interactions and the exposure to urine and faeces may result in irritant contact dermatitis, i.e. diaper dermatitis (DD) or incontinence-associated dermatitis (IAD). Babies with developing skin and the elderly with deteriorating skin functions who are the most frequent users of absorbent hygiene products are more vulnerable to the causal factors. Although irritant reactions are the most common, allergic contact dermatitis should be considered if a DD/IAD fails to improve by recommended actions. There is also a connection between IAD and pressure ulcer development of which it is important to be aware. A holistic approach of using high-quality absorbent hygiene products in combination with appropriate skin care will help maintaining good skin health.

  18. Temporal shaping of nanosecond CO2 laser pulses in multiphoton saturable absorbers

    International Nuclear Information System (INIS)

    Haglund, R.F. Jr.

    1981-01-01

    It was shown that substantial temporal distortion of nanosecond 10.6 μm laser pulses occurs in traversing multiphoton saturable absorbers. The risetime and pulse delay effects appear to depend both on fluence and wavelength, and to be qualitatively consistent with predictions of a simple two-level absorption model

  19. Carbon dioxide capture from reforming gases using acetic acid-mixed chemical absorbents

    Energy Technology Data Exchange (ETDEWEB)

    Rahmanian, Amin; Zaini, Muhammad Abbas ahmad; Abdullah, Tuan Amran Tuan [Faculty of Chemical Engineering, Universiti Teknologi Malaysia, Johor Bahru (Malaysia)

    2015-07-15

    Carbon dioxide (CO{sub 2}) is a major problem in the production of natural gas as it may contribute to the operational problems such as foaming, corrosion, high solution viscosity, and fouling, thereby decreasing the plant life. The presence of acid gas in natural gas reforming may also result in the increase of transported gas volume and the decrease of heating value. Absorption using aqueous solutions of alkanolamines has been a preferred approach in current industry for CO{sub 2} removal. Concentration of ammonia and DEA affects the CO{sub 2} removal; increasing the absorbents concentration increases the CO{sub 2} removal. On molar basis, DEA shows a greater CO{sub 2} absorption than ammonia. Acetic acid-mixed absorbents display a lower CO{sub 2} removal than the nonmixed ones. Decrease in solubility due to the decrease in solution pH has resulted in a lower CO{sub 2} absorption by acetic acid-mixed absorbents. Liquid flow rate offers only small influence on the absorption of CO{sub 2}, while decreasing the gas flow rate increases the CO{sub 2} removal. On the operational point of view, blend of ammonia and DEA absorbent would be beneficial for CO{sub 2} removal from reforming gases as it could partly solve the problems associated with regeneration and corrosion.

  20. An ultra-broadband multilayered graphene absorber

    KAUST Repository

    Amin, Muhammad; Farhat, Mohamed; Bagci, Hakan

    2013-01-01

    An ultra-broadband multilayered graphene absorber operating at terahertz (THz) frequencies is proposed. The absorber design makes use of three mechanisms: (i) The graphene layers are asymmetrically patterned to support higher order surface plasmon

  1. Characteristics and outcomes of patients with multiple myeloma aged 21-40years versus 41-60years

    DEFF Research Database (Denmark)

    Jurczyszyn, Artur; Nahi, Hareth; Avivi, Irit

    2016-01-01

    We compared the outcomes of multiple myeloma (MM) patients aged 21-40 and 41-60years in the novel agent era. This case-control study included 1089 patients between 2000 and 2015. Cases and controls were matched for sex, International Staging System (ISS) stage and institution. There were 173 pati...

  2. High-efficiency ventilated metamaterial absorber at low frequency

    Science.gov (United States)

    Wu, Xiaoxiao; Au-Yeung, Ka Yan; Li, Xin; Roberts, Robert Christopher; Tian, Jingxuan; Hu, Chuandeng; Huang, Yingzhou; Wang, Shuxia; Yang, Zhiyu; Wen, Weijia

    2018-03-01

    We demonstrate a ventilated metamaterial absorber operating at low frequency (90%) has been achieved in both simulations and experiments. This high-efficiency absorption under the ventilation condition originates from the weak coupling of two identical split tube resonators constituting the absorber, which leads to the hybridization of the degenerate eigenmodes and breaks the absorption upper limit of 50% for conventional transmissive symmetric acoustic absorbers. The absorber can also be extended to an array and work in free space. The absorber should have potential applications in acoustic engineering where both noise reduction and ventilation are required.

  3. Factors affecting neurodevelopmental outcome at 2 years in very preterm infants below 1250 grams: a prospective study.

    Science.gov (United States)

    Agarwal, Pratibha Keshav; Shi, Luming; Rajadurai, Victor Samuel; Zheng, Qishi; Yang, Phey Hong; Khoo, Poh Choo; Quek, Bin Huey; Daniel, Lourdes Mary

    2018-06-01

    To evaluate the neurodevelopmental outcomes of preterm very-low birth weight (PT/VLBW) infants at 2 years and identify risk factors associated with significant developmental delay or neurodevelopmental impairment (NDI). We evaluated 165 PT/VLBW infants born between January 2010 and December 2011, using the Bayley Scales of Infant and Toddler Development 3rd Edition (Bayley-III). NDI was defined as the presence of neurosensory impairment or significant delay with Bayley-III score deaf and none were blind. Regression models identified significant positive associations of delayed cognitive skills with male gender (Odds ratio (OR) 22.4, 95% confidence interval (CI) 1.5-341.1; P = 0.025), lack of anntenatal steroids (ANS) (OR 41.5, 95% CI 3.5-485.7; P = 0.003), and hypotension needing inotropes (OR 36.0, 95% CI 2.6-506.0; P = 0.008); delayed language skills with lower maternal education (OR 3.8, 95% CI 1.4-10.3; P = 0.10), lack of ANS (OR 2.8, 95% CI 1.1-7.4; P = 0.04), and 5 minute Apgar Score ≤ 5 (OR 7.4, 95% CI 1.4-38.4; P = 0.017) and delayed motor skills with chronic lung disease at 36 weeks (OR 38.3, 95% CI 2.4-603.4; P = 0.010). NDI was associated with lack of ANS (OR 2.91, 95% CI 1.21-7.00; P = 0.02) and use of postnatal steroids (OR 3.36, 95% CI 1.07-10.54; P = 0.0374). Risk factors for both NDI and individual domain delay were identified and will be helpful in planning of specific and targeted early intervention services.

  4. MMPI-2 profiles 23 years after paediatric mild traumatic brain injury.

    Science.gov (United States)

    Hessen, Erik; Anderson, Vicki; Nestvold, Knut

    2008-01-01

    Research suggest that post-concussive syndrome after mild traumatic brain injury (mTBI) is more common than chronic cognitive impairment. The aim of this study was to investigate very long-term outcome of subjective complaints after paediatric mTBI. The study was a follow-up 23 years after a prospective head injury study at a general hospital in Norway. Forty-one patients were assessed with the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) 23 years after sustaining mTBI as children. A good overall outcome was found with scores close to the normative mean, average length of education and normal employment rate. However, the children that sustained complicated mTBI showed slightly more pathological scores, typical for mild post-concussive syndrome. The most important predictors of poor outcome were skull fracture and a combination of post-traumatic amnesia > 30 minutes and EEG pathology within 24 hours after TBI. No influence of pre- and post-injury risk factors on current MMPI-2 profiles was evident. The results give support for the notion of potentially differential impact of uncomplicated vs complicated mTBI. The findings suggest that children and adolescents sustaining complicated mTBI may be at risk of developing subtle chronic symptoms typical of post-concussive syndrome.

  5. On (m, n)-absorbing ideals of commutative rings

    Indian Academy of Sciences (India)

    with respect to various ring theoretic constructions and study (m, n)-absorbing ideals in several commutative rings. For example, in a Bézout ring or a Boolean ring, an ideal is an (m, n)-absorbing ideal if and only if it is an n-absorbing ideal, and in an almost. Dedekind domain every (m, n)-absorbing ideal is a product of at ...

  6. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    2000-01-01

    The International Atomic Energy Agency published in 1987 an International Code of Practice entitled 'Absorbed Dose Determination in Photon and Electron Beams' (IAEA Technical Reports Series No. 277 (TRS-277)), recommending procedures to obtain the absorbed dose in water from measurements made with an ionization chamber in external beam radiotherapy. A second edition of TRS-277 was published in 1997 updating the dosimetry of photon beams, mainly kilovoltage X rays. Another International Code of Practice for radiotherapy dosimetry entitled 'The Use of Plane-Parallel Ionization Chambers in High Energy Electron and Photon Beams' (IAEA Technical Reports Series No. 381 (TRS-381)) was published in 1997 to further update TRS-277 and complement it with respect to the area of parallel-plate ionization chambers. Both codes have proven extremely valuable for users involved in the dosimetry of the radiation beams used in radiotherapy. In TRS-277 the calibration of the ionization chambers was based on primary standards of air kerma; this procedure was also used in TRS-381, but the new trend of calibrating ionization chambers directly in a water phantom in terms of absorbed dose to water was introduced. The development of primary standards of absorbed dose to water for high energy photon and electron beams, and improvements in radiation dosimetry concepts, offer the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. The dosimetry of kilovoltage X rays, as well as that of proton and heavy ion beams, interest in which has grown considerably in recent years, can also be based on these standards. Thus a coherent dosimetry system based on standards of absorbed dose to water is possible for practically all radiotherapy beams. Many Primary Standard Dosimetry Laboratories (PSDLs) already provide calibrations in terms of absorbed dose to water at the radiation quality of 60 Co gamma rays. Some laboratories have extended calibrations to high energy photon and

  7. Community integration 2 years after moderate and severe traumatic brain injury.

    Science.gov (United States)

    Sandhaug, Maria; Andelic, Nada; Langhammer, Birgitta; Mygland, Aase

    2015-01-01

    The aim of this study was to examine community integration by the Community Integration Questionnaire (CIQ) 2 years after injury in a divided TBI sample of moderately and severely injured patients. The second aim was to identify social-demographic, injury-related and rehabilitation associated predictors of CIQ. A cohort study. Outpatient follow-up. Fifty-seven patients with moderate (n = 21) or severe (n = 36) TBI were examined with the Community Integration Questionnaire (CIQ) at 2 years after injury. Possible predictors were analysed in a regression model using CIQ total score at 2 years as the outcome measure. The Community Integration Questionnaire. At 2 years follow-up, there was significant difference between the moderately and severely injured patients in the productivity scores (p productivity level than the severely injured patients. Marital status, injury severity and rehabilitation after injury were associated with community integration 2 years after TBI.

  8. Towards corrosion testing of unglazed solar absorber surfaces in simulated acid rain

    International Nuclear Information System (INIS)

    Salo, T.; Pehkonen, A.; Konttinen, P.; Lund, P.

    2005-01-01

    Electrochemical impedance spectroscopy and potentiodynamic polarization tests were utilized for determining corrosion probabilities of unglazed C/Al 2 O 3 /Al solar absorber surfaces in simulated acid rain. Previously, the main degradation mechanism found was exponentially temperature-related hydration of aluminium oxide. In acid rain tests the main corrosion determinant was the pH value of the rain. Results indicate that these methods measure corrosion characteristics of Al substrate instead of the C/Al 2 O 3 /Al surface, probably mainly due to the rough and non-uniform microstructure of the latter. Further analyses of the test methods are required in order to estimate their applicability on Al-based uniform sputtered absorber surfaces. (author) (C/Al 2 O 3 /Al solar absorber; Acid rain; Corrosion; Electrochemical tests)

  9. Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring.

    Science.gov (United States)

    Zajonz, Dirk; Franke, Anne-Catherine; von der Höh, Nicolas; Voelker, Anna; Moche, Michael; Gulow, Jens; Heyde, Christoph-Eckhard

    2014-01-01

    The stand-alone treatment of degenerative cervical spine pathologies is a proven method in clinical practice. However, its impact on subsidence, the resulting changes to the profile of the cervical spine and the possible influence of clinical results compared to treatment with additive plate osteosynthesis remain under discussion until present. This study was designed as a retrospective observational cohort study to test the hypothesis that radiographic subsidence of cervical cages is not associated with adverse clinical outcomes. 33 cervical segments were treated surgically by ACDF with stand-alone cage in 17 patients (11 female, 6 male), mean age 56 years (33-82 years), and re-examined after eight and twenty-six months (mean) by means of radiology and score assessment (Medical Outcomes Study Short Form (MOS-SF 36), Oswestry Neck Disability Index (ONDI), painDETECT questionnaire and the visual analogue scale (VAS)). Subsidence was observed in 50.5% of segments (18/33) and 70.6% of patients (12/17). 36.3% of cases of subsidence (12/33) were observed after eight months during mean time of follow-up 1. After 26 months during mean time of follow-up 2, full radiographic fusion was seen in 100%. MOS-SF 36, ONDI and VAS did not show any significant difference between cases with and without subsidence in the two-sample t-test. Only in one type of scoring (painDETECT questionnaire) did a statistically significant difference in t-Test emerge between the two groups (p = 0.03; α = 0.05). However, preoperative painDETECT score differ significantly between patients with subsidence (13.3 falling to 12.6) and patients without subsidence (7.8 dropped to 6.3). The radiological findings indicated 100% healing after stand-alone treatment with ACDF. Subsidence occurred in 50% of the segments treated. No impact on the clinical results was detected in the medium-term study period.

  10. Low back pain: conservative treatment with artificial shock absorbers.

    Science.gov (United States)

    Wosk, J; Voloshin, A S

    1985-03-01

    A new method of conservative treatment for low back pain (LBP) was studied by follow-up investigation of 382 patients during the last five years. The attempt to reduce repetitive impulsive intervertebral impact in the troublesome S1-L5-4 area by significant improvement of the foot's attenuational capacity through artificial viscoelastic shock absorbing was prompted by the authors' work on decreased capability of LBP spines to attenuate axially propagated walking stresses. Viscoelastic shoe inserts were used in addition to light flexible shoes as artificial shock absorbing devices. Maximal amplitudes of bone oscillation during walking were reduced by about 40% by the viscoelastic inserts. Rapid and surprisingly significant improvement of pain syndrome and patient mobility occurred in about 80% of the patients. The accelerographic patterns recorded on a sacrum of patient with LBP were unusual for a healthy subject; they usually disappeared after treatment in LBP cases. Results suggested that poor walking impact attenuation was a true cause for prolonging intervertebral structures overstrain and consequent degeneration. It seemed logical that as spine damage could be explained primarily by prolonged impulsive overstrain, treatment must include viscoelastic inserts which increase foot shock absorbing capacity and help cushion the spine.

  11. Cognitive outcome and reliable change indices two years following bilateral subthalamic nucleus deep brain stimulation.

    Science.gov (United States)

    Williams, Amy E; Arzola, Gladys Marina; Strutt, Adriana M; Simpson, Richard; Jankovic, Joseph; York, Michele K

    2011-06-01

    Subthalamic nucleus deep brain stimulation (STN-DBS) is currently the treatment of choice for medication-resistant levodopa-related motor complications in patients with Parkinson's disease (PD). While STN-DBS often results in meaningful motor improvements, consensus regarding long-term neuropsychological outcome continues to be debated. We assessed the cognitive outcomes of 19 STN-DBS patients compared to a group of 18 medically-managed PD patients on a comprehensive neuropsychological battery at baseline and two years post-surgery. Patients did not demonstrate changes in global cognitive functioning on screening measures. However, neuropsychological results revealed impairments in nonverbal recall, oral information processing speed, and lexical and semantic fluency in STN-DBS patients compared to PD controls 2 years post-surgery in these preliminary analyses. Additionally, reliable change indices revealed that approximately 50% of STN-DBS patients demonstrated significant declines in nonverbal memory and oral information processing speed compared to 25-30% of PD controls, and 26% of STN-DBS patients declined on lexical fluency compared to 11% of PD patients. Approximately 30% of both groups declined on semantic fluency. The number of STN-DBS patients who converted to dementia 2 years following surgery was not significantly different from the PD participants (32% versus 16%, respectively). Our results suggest that neuropsychological evaluations may identify possible mild cognitive changes following surgery. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Isoeffective dose: a concept for biological weighting of absorbed dose in proton and heavier-ion therapies

    CERN Document Server

    Wambersie, A; Menzel, H G; Gahbauer, R; DeLuca, P M; Hendry, J H; Jones, D T L

    2011-01-01

    When reporting radiation therapy procedures, International Commission on Radiation Units and Measurements (ICRU) recommends specifying absorbed dose at/in all clinically relevant points and/or volumes. In addition, treatment conditions should be reported as completely as possible in order to allow full understanding and interpretation of the treatment prescription. However, the clinical outcome does not only depend on absorbed dose but also on a number of other factors such as dose per fraction, overall treatment time and radiation quality radiation biology effectiveness (RBE). Therefore, weighting factors have to be applied when different types of treatments are to be compared or to be combined. This had led to the concept of `isoeffective absorbed dose', introduced by ICRU and International Atomic Energy Agency (IAEA). The isoeffective dose D(IsoE) is the dose of a treatment carried out under reference conditions producing the same clinical effects on the target volume as those of the actual treatment. It i...

  13. Environmental Volunteering and Health Outcomes over a 20-Year Period

    Science.gov (United States)

    Pillemer, Karl; Fuller-Rowell, Thomas E.; Reid, M. C.; Wells, Nancy M.

    2010-01-01

    Purpose: This study tested the hypothesis that volunteering in environmental organizations in midlife is associated with greater physical activity and improved mental and physical health over a 20-year period.  Design and Methods: The study used data from two waves (1974 and 1994) of the Alameda County Study, a longitudinal study of health and mortality that has followed a cohort of 6,928 adults since 1965. Using logistic and multiple regression models, we examined the prospective association between environmental and other volunteerism and three outcomes (physical activity, self-reported health, and depression), with 1974 volunteerism predicting 1994 outcomes, controlling for a number of relevant covariates.  Results: Midlife environmental volunteering was significantly associated with physical activity, self-reported health, and depressive symptoms.  Implications: This population-based study offers the first epidemiological evidence for a significant positive relationship between environmental volunteering and health and well-being outcomes. Further research, including intervention studies, is needed to confirm and shed additional light on these initial findings. PMID:20172902

  14. Analisa Unjuk Kerja Motor Bakar Berbahan Bakar Biogas Termurnikan Berbasis Absorber Fe2o3

    OpenAIRE

    Sutanto, Rudy; Alit, Ida Bagus; Nurchayati, Nurchayati

    2014-01-01

    The long-term aim of this research is to obtain a biogas what the renewable natural gas quality and can be used to fuel an electric generator to support the availability of electricity in the region of small islands. Specific targets to be achieved is to determine whether the binding of H2S in biogas can raise engine performance of the machine, information technology, and the active materials so comprehensive to absorb hydrogen sulfide gas as materials of the textbook writing and articles for...

  15. Multi-Level Experimental and Analytical Evaluation of Two Composite Energy Absorbers

    Science.gov (United States)

    Jackson, Karen E.; Littell, Justin D.; Fasanella, Edwin L.; Annett, Martin S.; Seal, Michael D., II

    2015-01-01

    Two composite energy absorbers were developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program. A conical-shaped energy absorber, designated the conusoid, was evaluated that consisted of four layers of hybrid carbon-Kevlar plain weave fabric oriented at [+45 deg/-45 deg/-45 deg/+45 deg] with respect to the vertical, or crush, direction. A sinusoidal-shaped energy absorber, designated the sinusoid, was developed that consisted of hybrid carbon-Kevlar plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical direction and a closed-cell ELFOAM P200 polyisocyanurate (2.0-lb/cu ft) foam core. The design goal for the energy absorbers was to achieve average floor-level accelerations of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in both designs were assessed through dynamic crush testing of component specimens. Once the designs were finalized, subfloor beams of each configuration were fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorbers prior to retrofit into TRACT 2. The retrofitted airframe was crash tested under combined forward and vertical velocity conditions onto soil, which is characterized as a sand/clay mixture. Finite element models were developed of all test articles and simulations were performed using LS-DYNA, a commercial nonlinear explicit transient dynamic finite element code. Test-analysis results are presented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading for each evaluation level.

  16. I Wish I Had (Not) Taken a Gap-Year? The Psychological and Attainment Outcomes of Different Post-School Pathways

    Science.gov (United States)

    Parker, Philip D.; Thoemmes, Felix; Duineveld, Jasper J.; Salmela-Aro, Katariina

    2015-01-01

    Existing gap-year research indicates a number of benefits of a gap-year at the end of school and before university enrollment. Life span theory of control, however, suggests that direct goal investment, rather than delay, at developmental transitions is associated with more adaptive outcomes. Comparing these perspectives, the authors undertook 2

  17. Precious metals in SDSS quasar spectra. II. Tracking the evolution of strong, 0.4 < z < 2.3 Mg II absorbers with thousands of systems

    International Nuclear Information System (INIS)

    Seyffert, Eduardo N.; Simcoe, Robert A.; Cooksey, Kathy L.; O'Meara, John M.; Kao, Melodie M.; Prochaska, J. Xavier

    2013-01-01

    We have performed an analysis of over 34,000 Mg II doublets at 0.36 < z < 2.29 in Sloan Digital Sky Survey (SDSS) Data Release 7 quasar spectra; the catalog, advanced data products, and tools for analysis are publicly available. The catalog was divided into 14 small redshift bins with roughly 2500 doublets in each and from Monte Carlo simulations, we estimate 50% completeness at rest equivalent width W r ≈ 0.8 Å. The equivalent width frequency distribution is described well by an exponential model at all redshifts, and the distribution becomes flatter with increasing redshift, i.e., there are more strong systems relative to weak ones. Direct comparison with previous SDSS Mg II surveys reveals that we recover at least 70% of the doublets in these other catalogs, in addition to detecting thousands of new systems. We discuss how these surveys came by their different results, which qualitatively agree but because of the very small uncertainties, differ by a statistically significant amount. The estimated physical cross section of Mg II-absorbing galaxy halos increased approximately threefold from z = 0.4 to z = 2.3, while the W r ≥ 1 Å absorber line density, dN MgII /dX, grew by roughly 45%. Finally, we explore the different evolution of various absorber populations—damped Lyα absorbers, Lyman limit systems, strong C IV absorbers, and strong and weaker Mg II systems—across cosmic time (0 < z < 6).

  18. New burnable absorber for long-cycle low boron operation of PWRs

    International Nuclear Information System (INIS)

    Choe, Jiwon; Shin, Ho Cheol; Lee, Deokjung

    2016-01-01

    Highlights: • A burnable absorber design for advanced PWRs with a low soluble boron concentration. • The burnable absorber consists of a UO 2 – 157 Gd 2 O 3 rod with a thin layer of Zr 167 Er 2 . • Three verification cases: two kinds of fuel assemblies and an OPR-1000 core. - Abstract: This paper presents a new high performance burnable absorber (BA) design for advanced Pressurized Water Reactors (PWRs) aiming for a long-cycle operation with a low soluble boron concentration. The new BA consists of a UO 2 – 157 Gd 2 O 3 rod covered with a thin layer of Zr 167 Er 2 . A key feature of this new BA is that enriched isotopes, 157 Gd and 167 Er, are used as absorber materials. Since the high absorption cross section of 157 Gd can reduce the mass fraction of Gd 2 O 3 in UO 2 –Gd 2 O 3 , the thermal margin of fuel rods will increase with higher heat conductivity. Also, the 157 Gd transmutes into 158 Gd by neutron absorption and therefore the residual penalty at the end of cycle (EOC) will decrease. Since 167 Er has a resonance near the thermal neutron energy region, the moderator temperature coefficient (MTC) will become more negative and the control rod worth will increase. These advantages of the new BA are demonstrated with three verification cases: a 17 × 17 Westinghouse (WH) type fuel assembly, a 16 × 16 Combustion Engineering (CE) type fuel assembly, and an OPR-1000 equilibrium core.

  19. Influence of Striking Edge Radius (2 mm versus 8 mm) on Instrumented Charpy Data and Absorbed Energies

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-08-15

    The most commonly used test standards for performing Charpy impact tests (ISO 148 and ASTM E 23) envisage the use of strikers having different radii of the striking edge, i.e. 2 mm (ISO) and 8 mm (ASTM). The effect of striker geometry on Charpy results was extensively studied in the past in terms of absorbed energy measured by the machine encoder, but few investigations are available on the influence of striker configuration on the results of instrumented Charpy tests (characteristic forces, displacements and integrated energy). In this paper, these effects are investigated based on the analysis of published results from three interlaboratory studies and some unpublished Charpy data obtained at SCK-CEN. The instrumented variables which are the most sensitive to the radius of the striking edge are the maximum force and its corresponding displacement, with 8mm-strikers providing systematically higher values. Absorbed energies, obtained both from the instrumented trace and from the pendulum encoder, are almost insensitive to the type of striker up to 200 J. For higher energy levels, the values obtained from 8mm strikers become progressively larger. Data scatter is generally higher for 2mm-strikers.

  20. Performance evaluation of CFRP-rubber shock absorbers

    Science.gov (United States)

    Lamanna, Giuseppe; Sepe, Raffaele

    2014-05-01

    In the present work a numerical investigation on the energy absorbing capability of dedicated structural components made of a carbon fiber reinforced polymer and an emulsion polymerised styrene butadiene rubber is reported. The shock absorbers are devices designed to absorb large amounts of energy by sacrificing their own structural integrity. Their aim is to cushion the effects of an impact phenomenon with the intent to preserve other structures from global failure or local damaging. Another important role of shock absorbers is reducing the peak of the acceleration showed during an impact phenomenon. This effect is of considerable interest in the case of vehicles to preserve passengers' safety. Static and dynamic numerical results are compared with experimental ones in terms of mean crushing forces, energy and peak crushing. The global performance of the absorbers has been evaluated by referencing to a proposed quality index.

  1. Performance evaluation of CFRP-rubber shock absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Lamanna, Giuseppe, E-mail: giuseppe.lamanna@unina2.it; Sepe, Raffaele, E-mail: giuseppe.lamanna@unina2.it [Department of Industrial and Information Engineering, Second University of Naples, via Roma, 29 - 81031 Aversa (Italy)

    2014-05-15

    In the present work a numerical investigation on the energy absorbing capability of dedicated structural components made of a carbon fiber reinforced polymer and an emulsion polymerised styrene butadiene rubber is reported. The shock absorbers are devices designed to absorb large amounts of energy by sacrificing their own structural integrity. Their aim is to cushion the effects of an impact phenomenon with the intent to preserve other structures from global failure or local damaging. Another important role of shock absorbers is reducing the peak of the acceleration showed during an impact phenomenon. This effect is of considerable interest in the case of vehicles to preserve passengers’ safety. Static and dynamic numerical results are compared with experimental ones in terms of mean crushing forces, energy and peak crushing. The global performance of the absorbers has been evaluated by referencing to a proposed quality index.

  2. Effect of pyrophyllite filler treatment toward water absorbance rate of SAPC and its application test

    International Nuclear Information System (INIS)

    Jadigia Ginting

    2015-01-01

    An optimization treatment to pyrophyllite filler has been done to synthesis super absorbent polymers composite (SAPC) with copolymerization of acrylic. Pyrophyllite is one of a silicate mineral with chemical formula Al 2 Si 4 O 10 (OH) 2 having a reactive functional group -OH that easily making a bonding and therefore it is suitable for water absorbance materials. The pyrophyllite were studied as its weight composition and its powder-size in the SAPC preparation. To obtain the fine-size, the filler pyrophyllite were milled with high energy mechanical milling (HEMM) into divers hours of milling. The syntheses were carried out by using the settle method from Chemicals Engineering group of ITB Bandung. The samples of SAPC-prflt were then characterized with fourier-transform infra red spectroscopy (FTIR), Xray diffraction (XRD) and scanning electron microscopy(SEM). Effect of filler treatment toward water absorbance rate is the SAPC-prflt with 0.5 gr filler having the highest gradient absorbance 1,610; SAPC prflt which milled for 9 hours has gradient absorbance 1,526; SAPC-prflt after hot water test at 40°C has gradient absorbence 2,241 and SAPC-prflt as pampers test has the gradient absorbance 1,607. XRD data analysis showed a broad peak 2 θ at scale 5 w which correspond to the micrographs picture of the sample which has 0.5 gr filler pyrophyllite and sample after milled for 9 hours, that proposed increase the sample strength and stability which induce the increasing of its water absorbance.

  3. Overlapping bio-absorbable scaffolds: Aim for D2D technique?

    Science.gov (United States)

    Khan, Asaad A; Dangas, George D

    2018-06-01

    The results of overlapping metallic stents have been concerning but this practice is often unavoidable in the setting of long or tortuous lesions, diameter discrepancy of proximal and distal vessel, and for residual dissections. Theoretically, bio-absorbable scaffolds may carry an advantage over metallic stents due to the progressive resorption of the scaffold theoretically rendering the overlap a non-issue; this has not been clinically evident. Since stent/scaffold overlap cannot be entirely avoided, improved stent delivery/deployment and scaffold design modification may reduce complications in this complex patient subset. © 2018 Wiley Periodicals, Inc.

  4. Annealing effect on the structural and optical properties of Cr/α-Cr2O3 monodispersed particles based solar absorbers

    International Nuclear Information System (INIS)

    Khamlich, S.; McCrindle, R.; Nuru, Z.Y.; Cingo, N.; Maaza, M.

    2013-01-01

    Graphical abstract: A cost-effective and environmentally friendly green chemical method, the so-called aqueous chemical growth (ACG) method, was used to deposit chromium/alpha-chromium(III) oxide, Cr/α-Cr 2 O 3 , monodispersed particles, for solar absorbers applications. Highlights: ► Cr/α-Cr 2 O 3 have been deposited by the aqueous chemical growth (ACG) method. ► High temperature annealing affects the optical selectivity of the deposited particles. ► Oxygen diffusion to the interface at high temperature results in the oxidization of the substrate. - Abstract: A cost-effective and environmentally friendly green chemical method, the so-called aqueous chemical growth (ACG) method, was used to deposit chromium/alpha-chromium(III) oxide, Cr/α-Cr 2 O 3 , monodispersed particles, for solar absorbers applications. The deposited particles were annealed at various temperatures in a hydrogen atmosphere for 2 h to study the annealing temperature dependence of the structural, chemical and optical properties of the particles grown on tantalum substrates. The deposited Cr/α-Cr 2 O 3 was characterized by X-ray diffraction (XRD), attenuated total reflection (ATR), scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), and diffuse reflectance UV–vis–NIR spectroscopy. The XRD and ATR analysis indicated that by increasing annealing temperature, the particles crystallinity was improved and Ta 2 O 5 was formed around 600 °C, due to the fast oxygen diffusion from the deposited α-Cr 2 O 3 toward the tantalum substrate. The optical measurements show that samples annealed at 400 and 500 °C exhibit the targeted high absorbing optical characteristics of “Black chrome”, while those annealed below 400 °C and above 500 °C show a significant low absorptivity and high emissivity.

  5. Precision test method by x-ray absorbent clay

    International Nuclear Information System (INIS)

    Nakadai, Toru; Matsukawa, Hideyuki; Sekita, Jun-ichiro; Murakoshi, Atsushi.

    1982-01-01

    In X-ray penetration photography of such as welds with reinforcing metal and castings of complex shape, the X-ray absorbent clay developed to eliminate various disadvantages of the conventional absorbents was further studied for better application. The results of the usage are as follows. Because the X-ray absorbent is clay, it is flexible in form, and gives good adhesion to test objects. In the welds and castings mentioned, it is effective for reducing the scattered ray, accordingly, it results in superior images. The following matters are described: contrast in radiographs, the required conditions for X-ray absorbents in general, the properties of the absorbent (absorption coefficient, consistency, density), improvement in radiographs by means of the X-ray absorbent clay (wall thickness compensation, masking, the application together with narrow-field irradiation photography). (Mori, K.)

  6. Shared care or nursing consultations as an alternative to rheumatologist follow-up for rheumatoid arthritis outpatients with low disease activity--patient outcomes from a 2-year, randomised controlled trial

    DEFF Research Database (Denmark)

    Primdahl, Jette; Sørensen, Jan; Horn, Hans Christian

    2014-01-01

    were randomised to 2-year follow-up by either: (1) planned rheumatologist consultations, (2) shared care without planned consultations or (3) planned nursing consultations. The primary outcome was change in disease activity. DAS28-CRP, Health Assessment Questionnaire, visual analogue scale (VAS......)-pain, fatigue, global health, confidence and satisfaction, quality-of-life by the Short Form 12 and self-efficacy measured by the RA Self-Efficacy questionnaire and the Arthritis Self-Efficacy Scale, were recorded annually and safety measures were recorded. x-Rays of hands and feet were taken at baseline...... and at 2-year follow-up. Mixed effect models were used to explore differences between the three groups over time. RESULTS: At 2-year follow-up, the group allocated to nursing consultations had lower disease activity than the group that underwent rheumatologist consultations (DAS28-CRP -0.3, p=0...

  7. Group cognitive behavioral therapy for patients with generalized social anxiety disorder in Japan: outcomes at 1-year follow up and outcome predictors

    Science.gov (United States)

    Kawaguchi, Akiko; Watanabe, Norio; Nakano, Yumi; Ogawa, Sei; Suzuki, Masako; Kondo, Masaki; Furukawa, Toshi A; Akechi, Tatsuo

    2013-01-01

    Background Social anxiety disorder (SAD) is one of the most common psychiatric disorders worldwide. Cognitive behavioral therapy (CBT) is an effective treatment option for patients with SAD. In the present study, we examined the efficacy of group CBT for patients with generalized SAD in Japan at 1-year follow-up and investigated predictors with regard to outcomes. Methods This study was conducted as a single-arm, naturalistic, follow-up study in a routine Japanese clinical setting. A total of 113 outpatients with generalized SAD participated in group CBT from July 2003 to August 2010 and were assessed at follow-ups for up to 1 year. Primary outcome was the total score on the Social Phobia Scale/Social Interaction Anxiety Scale (SPS/SIAS) at 1 year. Possible baseline predictors were investigated using mixed-model analyses. Results Among the 113 patients, 70 completed the assessment at the 1-year follow-up. The SPS/SIAS scores showed significant improvement throughout the follow-ups for up to 1 year. The effect sizes of SPS/SIAS at the 1-year follow-up were 0.68 (95% confidence interval 0.41–0.95)/0.76 (0.49–1.03) in the intention-to-treat group and 0.77 (0.42–1.10)/0.84 (0.49–1.18) in completers. Older age at baseline, late onset, and lower severity of SAD were significantly associated with good outcomes as a result of mixed-model analyses. Conclusions CBT for patients with generalized SAD in Japan is effective for up to 1 year after treatment. The effect sizes were as large as those in previous studies conducted in Western countries. Older age at baseline, late onset, and lower severity of SAD were predictors for a good outcome from group CBT. PMID:23450841

  8. Energy Absorbing Effectiveness – Different Approaches

    Directory of Open Access Journals (Sweden)

    Kotełko Maria

    2018-03-01

    Full Text Available In the paper the study of different crashworthiness indicators used to evaluate energy absorbing effectiveness of thin-walled energy absorbers is presented. Several different indicators are used to assess an effectiveness of two types of absorbing structures, namely thin-walled prismatic column with flaws and thin-walled prismatic frustum (hollow or foam filled in both cases subjected to axial compressive impact load. The indicators are calculated for different materials and different geometrical parameters. The problem of selection of the most appropriate and general indicators is discussed.

  9. Development and qualification of reference calculation schemes for absorbers in pressured water reactor

    International Nuclear Information System (INIS)

    Blanc-Tranchant, P.

    2001-01-01

    The general field in which this work takes place is the field of the accuracy improvement of neutronic calculations, required to operate Pressurized Water Reactors (PWR) with a better precision and a lower cost. More specifically, this thesis deals with the calculation of the absorber clusters used to control these reactors. The first aim of that work was to define and validate a reference calculation route of such an absorber cluster, based on the deterministic code APOLLO2. This calculation scheme was then to be checked against experimental data. This study of the complex situation of absorber clusters required several intermediate studies, of simpler problems, such as the study of fuel rods lattices and the study of single absorber rods (B4C, AIC, Hafnium) isolated in such lattices. Each one of these different studies led to a particular reference calculation route. All these calculation routes were developed against reference continuous energy Monte-Carlo calculations, carried out with the stochastic code TRIPOLI4. They were then checked against experimental data measured during French experimental programs, undertaken within the EOLE experimental reactor, at the Nuclear Research Center of Cadarache: the MISTRAL experiments for the study of isolated absorber rods and the EPICURE experiments for the study of absorber clusters. This work led to important improvements in the calculation of isolated absorbers and absorber clusters. The reactivity worth of these clusters in particular, can now be obtained with a great accuracy: the discrepancy observed between the calculated and the experimental values is less than 2.5 %, and then slightly lower than the experimental uncertainty. (author)

  10. Adjustable Shock Absorbers

    OpenAIRE

    Adamiec, Radek

    2012-01-01

    Bakalářská práce obsahuje přehled používaných tlumičů osobních automobilů, závodních automobilů a motocyklů. Jsou zde popsány systémy t lumením, konstrukce tlumičů a vidlic používaných u motocyklů. Dále je zde přehled prvků používaných u podvozků automobilů. This bachelor´s thesis contains the survey of the shock absorbers of passenger cars, racing cars and motorcycles. Are described damping systems, the design used shock absorbers and forks for motorcycles. Then there is the list of the e...

  11. Slow and Fast Light in an Electro-Absorber

    DEFF Research Database (Denmark)

    Öhman, Filip; Bermejo Ramirez, Andres; Sales, Salvador

    2006-01-01

    We demonstrate controllable and large time delay in cascaded semiconductor saturable absorbers and amplifiers. The possibility of further increasing the tuneable phase shift by utilizing field screening effects in the quantum well absorber is demonstrated.......We demonstrate controllable and large time delay in cascaded semiconductor saturable absorbers and amplifiers. The possibility of further increasing the tuneable phase shift by utilizing field screening effects in the quantum well absorber is demonstrated....

  12. Absorbing Aerosols: Field and Laboratory Studies of Black Carbon and Dust

    Science.gov (United States)

    Aiken, A. C.; Flowers, B. A.; Dubey, M. K.

    2011-12-01

    Currently, absorbing aerosols are thought to be the most uncertain factor in atmospheric climate models (~0.4-1.2 W/m2), and the 2nd most important factor after CO2 in global warming (1.6 W/m2; Ramanathan and Carmichael, Nature Geoscience, 2008; Myhre, Science, 2009). While most well-recognized atmospheric aerosols, e.g., sulfate from power-plants, have a cooling effect on the atmosphere by scattering solar radiation, black carbon (BC or soot) absorbs sunlight strongly which results in a warming of the atmosphere. Dust particles are also present globally and can absorb radiation, contributing to a warmer and drier atmosphere. Direct on-line measurements of BC and hematite, an absorbing dust aerosol, can be made with the Single Particle Soot Photometer (SP2), which measures the mass of the particles by incandescence on an individual particle basis. Measurements from the SP2 are combined with absorption measurements from the three-wavelength photoacoustic soot spectrometer (PASS-3) at 405, 532, and 781 nm and the ultraviolet photoacoustic soot spectrometer (PASS-UV) at 375 nm to determine wavelength-dependent mass absorption coefficients (MACs). Laboratory aerosol samples include flame-generated soot, fullerene soot, Aquadag, hematite, and hematite-containing dusts. Measured BC MAC's compare well with published values, and hematite MAC's are an order of magnitude less than BC. Absorbing aerosols measured in the laboratory are compared with those from ambient aerosols measured during the Las Conchas fire and BEACHON-RoMBAS. The Las Conchas fire was a wildfire in the Jemez Mountains of New Mexico that burned over 100,000 acres during the Summer of 2011, and BEACHON-RoMBAS (Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics & Nitrogen - Rocky Mountain Biogenic Aerosol Study) is a field campaign focusing on biogenic aerosols at the Manitou Forest Observatory near Colorado Springs, CO in Summer 2011. Optical properties and size

  13. MODERATE C IV ABSORBER SYSTEMS REQUIRE 10{sup 12} M{sub Sun} DARK MATTER HALOS AT z {approx} 2.3: A CROSS-CORRELATION STUDY OF C IV ABSORBER SYSTEMS AND QUASARS IN SDSS-III BOSS DR9

    Energy Technology Data Exchange (ETDEWEB)

    Vikas, Shailendra; Wood-Vasey, W. Michael [Pittsburgh Particle Physics, Astrophysics, and Cosmology Center (PITT PACC), Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Lundgren, Britt [Department of Physics, Yale University, New Haven, CT 06511 (United States); Ross, Nicholas P. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 92420 (United States); Myers, Adam D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); AlSayyad, Yusra [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); York, Donald G. [Department of Astronomy, University of Chicago, 5640 S. Ellis Ave, Chicago, IL 60637 (United States); Schneider, Donald P. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Brinkmann, J.; Bizyaev, Dmitry; Brewington, Howard; Malanushenko, Elena; Malanushenko, Viktor; Oravetz, Daniel; Pan, Kaike; Snedden, Stephanie [Apache Point Observatory, P.O. Box 59, Sunspot, NM 88349-0059 (United States); Ge, Jian [Department of Astronomy, University of Florida, Gainesville, FL 32611 (United States); Muna, Demitri [Center for Cosmology and Particle Physics, New York University, New York, NY 10003 (United States); Paris, Isabelle; Petitjean, Patrick, E-mail: skv4@pitt.edu [UPMC-CNRS, UMR7095, Institut d' Astrophysique de Paris, F-75014 Paris (France); and others

    2013-05-01

    We measure the two-point cross-correlation function of C IV absorber systems and quasars, using spectroscopic data from the Sloan Digital Sky Survey III Baryon Oscillation Spectroscopic Survey (BOSS; Data Release 9). The 19,701 quasars and 6149 C IV ''moderate'' absorbers, 0.28 A < rest-frame equivalent width (EW) < 5 A, in our study cover a redshift range of 2.1 < z < 2.5 over 3300 deg{sup 2} and represent a factor of two increase in sample size over previous investigations. We find a correlation scale length and slope of the redshift-space cross-correlation function of s{sub 0} = 8.46 {+-} 1.24 Mpc, {gamma} = 1.68 {+-} 0.19, in the redshift-space range 10 < s < 100 Mpc. We find a projected cross-correlation function of C IV absorption systems and quasars of r{sub 0} = 7.76 {+-} 2.80 Mpc, {gamma} = 1.74 {+-} 0.21. We measure the combined quasar and C IV bias to be b{sub QSO} b{sub C{sub IV}} = 8.81 {+-} 2.28. Using an estimate of b{sub QSO} from the quasar auto-correlation function we find b{sub CIV} = 2.38 {+-} 0.62. This b{sub CIV} implies that EW > 0.28 A C IV absorbers at z {approx} 2.3 are typically found in dark matter halos that have masses {>=}10{sup 11.3}-10{sup 13.4} M{sub Sun} at that redshift. The complete BOSS sample will triple the number of both quasars and absorption systems and increase the power of this cross-correlation measurement by a factor of two.

  14. Employment Outcome Ten Years after Moderate to Severe Traumatic Brain Injury: A Prospective Cohort Study.

    Science.gov (United States)

    Grauwmeijer, Erik; Heijenbrok-Kal, Majanka H; Haitsma, Ian K; Ribbers, Gerard M

    2017-09-01

    The objective of this prospective cohort study was to evaluate the probability of employment and predictors of employment in patients with moderate- to- severe traumatic brain injury (TBI) over 10-year follow-up. One hundred nine patients (18-67 years) were included with follow-up measurements 3, 6, 12, 18, 24, and 36 months and 10 years post-TBI. Potential predictors of employment probability included patient characteristics, injury severity factors, functional outcome measured at discharge from the hospital with the Glasgow Outcome Scale (GOS), Barthel Index (BI), Functional Independence Measure (FIM), and the Functional Assessment Measure (FAM). Forty-eight patients (42%) completed the 10-year follow-up. Three months post-TBI, 12% were employed, which gradually, but significantly, increased to 57% after 2-years follow-up (p employed persons had less-severe TBI, shorter length of hospital stay (LOS), and higher scores on the GOS, BI, FIM, and FAM at hospital discharge than unemployed persons. No significant differences in age, sex, educational level, living with partner/family or not, pre-injury employment, professional category, psychiatric symptoms, or discharge destination were found. Longitudinal multivariable analysis showed that time, pre-injury employment, FAM, and LOS were independent predictors of employment probability. We concluded that employment probability 10 years after moderate or severe TBI is related to injury severity and pre-injury employment. Future studies on vocational rehabilitation should focus on modifiable factors and take into consideration the effects of national legislation and national labor market forces.

  15. Thermal properties of polyfurfuryl alcohol absorbed/adsorbed on arylated soy protein films

    CSIR Research Space (South Africa)

    Kumar, R

    2012-02-01

    Full Text Available In this study, polyfurfuryl alcohol was absorbed/adsorbed on soy protein isolate films by immersing the SPI films in acid-catalysed furfuryl alcohol solution for 60 h followed by complete curing at 145–150 -C for 2 h. PFA absorbed/adsorbed soy...

  16. Development and qualification of reference calculation schemes for absorbers in pressured water reactor; Elaboration et qualification de schemas de calcul de reference pour les absorbants dans les reacteurs a eau pressurisee

    Energy Technology Data Exchange (ETDEWEB)

    Blanc-Tranchant, P

    2001-07-01

    The general field in which this work takes place is the field of the accuracy improvement of neutronic calculations, required to operate Pressurized Water Reactors (PWR) with a better precision and a lower cost. More specifically, this thesis deals with the calculation of the absorber clusters used to control these reactors. The first aim of that work was to define and validate a reference calculation route of such an absorber cluster, based on the deterministic code APOLLO2. This calculation scheme was then to be checked against experimental data. This study of the complex situation of absorber clusters required several intermediate studies, of simpler problems, such as the study of fuel rods lattices and the study of single absorber rods (B4C, AIC, Hafnium) isolated in such lattices. Each one of these different studies led to a particular reference calculation route. All these calculation routes were developed against reference continuous energy Monte-Carlo calculations, carried out with the stochastic code TRIPOLI4. They were then checked against experimental data measured during French experimental programs, undertaken within the EOLE experimental reactor, at the Nuclear Research Center of Cadarache: the MISTRAL experiments for the study of isolated absorber rods and the EPICURE experiments for the study of absorber clusters. This work led to important improvements in the calculation of isolated absorbers and absorber clusters. The reactivity worth of these clusters in particular, can now be obtained with a great accuracy: the discrepancy observed between the calculated and the experimental values is less than 2.5 %, and then slightly lower than the experimental uncertainty. (author)

  17. Impact of Renal Replacement Therapy in Childhood on Long-Term Socioprofessional Outcomes: A 30-year Follow-Up Study

    NARCIS (Netherlands)

    Tjaden, Lidwien A.; Maurice-Stam, Heleen; Grootenhuis, Martha A.; Jager, Kitty J.; Groothoff, Jaap W.

    2016-01-01

    To evaluate socioprofessional outcomes after 30 years of renal replacement therapy (RRT) and explore predictors of these outcomes. The cohort comprised all Dutch patients, born before 1979, who started RRT at age <15 years in 1972-1992. Outcomes including family life, educational attainment, and

  18. Carbon dioxide absorber and regeneration assemblies useful for power plant flue gas

    Science.gov (United States)

    Vimalchand, Pannalal; Liu, Guohai; Peng, Wan Wang

    2012-11-06

    Disclosed are apparatus and method to treat large amounts of flue gas from a pulverized coal combustion power plant. The flue gas is contacted with solid sorbents to selectively absorb CO.sub.2, which is then released as a nearly pure CO.sub.2 gas stream upon regeneration at higher temperature. The method is capable of handling the necessary sorbent circulation rates of tens of millions of lbs/hr to separate CO.sub.2 from a power plant's flue gas stream. Because pressurizing large amounts of flue gas is cost prohibitive, the method of this invention minimizes the overall pressure drop in the absorption section to less than 25 inches of water column. The internal circulation of sorbent within the absorber assembly in the proposed method not only minimizes temperature increases in the absorber to less than 25.degree. F., but also increases the CO.sub.2 concentration in the sorbent to near saturation levels. Saturating the sorbent with CO.sub.2 in the absorber section minimizes the heat energy needed for sorbent regeneration. The commercial embodiments of the proposed method can be optimized for sorbents with slower or faster absorption kinetics, low or high heat release rates, low or high saturation capacities and slower or faster regeneration kinetics.

  19. Performance of an absorbing concentrating solar collectors

    International Nuclear Information System (INIS)

    Imadojemu, H.

    1990-01-01

    This paper reports on a comparison of the efficiency of an absorbing fluid parabolic trough concentrating solar collector and a traditional concentrating collector that was made. In the absorbing fluid collector, black liquid flows through a glass tube absorber while the same black liquid flows through a selective black coated copper tube absorber while the same black fluid flows through a selective black coated copper tube absorber in the traditional collector. After a careful study of the properties of available black liquids, a mixture of water and black ink was chosen as the black absorbing medium or transfer fluid. In the black liquid glass collector there is a slightly improved efficiency based on beam radiation as a result of the direct absorption process and an increase in the effective transmittance absorptance. At worst the efficiency of this collector equals that of the traditional concentrating collector when the efficiency is based on total radiation. The collector's reflecting surfaces were made of aluminum sheet, parabolic line focus and with cylindrical receivers. The ease of manufacture and reduced cost per unit energy collected, in addition to the clean and pollution free mode of energy conversion, makes it very attractive

  20. Preterm brain injury on term-equivalent age MRI in relation to perinatal factors and neurodevelopmental outcome at two years.

    Directory of Open Access Journals (Sweden)

    Margaretha J Brouwer

    Full Text Available First, to apply a recently extended scoring system for preterm brain injury at term-equivalent age (TEA-MRI in a regional extremely preterm cohort; second, to identify independent perinatal factors associated with this score; and third, to assess the prognostic value of this TEA-MRI score with respect to early neurodevelopmental outcome.239 extremely preterm infants (median gestational age [range] in weeks: 26.6 [24.3-27.9], admitted to the Wilhelmina Children's Hospital between 2006 and 2012 were included. Brain abnormalities in white matter, cortical and deep grey matter and cerebellum and brain growth were scored on T1- and T2-weighted TEA-MRI using the Kidokoro scoring system. Neurodevelopmental outcome was assessed at two years corrected age using the Bayley Scales of Infant and Toddler Development, third edition. The association between TEA-MRI and perinatal factors as well as neurodevelopmental outcome was evaluated using multivariable regression analysis.The distribution of brain abnormalities and brain metrics in the Utrecht cohort differed from the original St. Louis cohort (p 7 days (β [95% confidence interval, CI]: 1.3 [.5; 2.0] and parenteral nutrition >21 days (2.2 [1.2; 3.2] were independently associated with higher global brain abnormality scores (p < .001. Global brain abnormality scores were inversely associated with cognitive (β in composite scores [95% CI]: -.7 [-1.2; -.2], p = .004, fine motor (β in scaled scores [95% CI]: -.1 [-.3; -.0], p = .007 and gross motor outcome (β in scaled scores [95% CI]: -.2 [-.3; -.1], p < .001 at two years corrected age, although the explained variances were low (R2 ≤.219.Patterns of brain injury differed between cohorts. Prolonged mechanical ventilation and parenteral nutrition were identified as independent perinatal risk factors. The prognostic value of the TEA-MRI score was rather limited in this well-performing cohort.

  1. Hospital-acquired pneumonia is an independent predictor of poor global outcome in severe traumatic brain injury up to 5 years after discharge.

    Science.gov (United States)

    Kesinger, Matthew Ryan; Kumar, Raj G; Wagner, Amy K; Puyana, Juan Carlos; Peitzman, Andrew P; Billiar, Timothy R; Sperry, Jason L

    2015-02-01

    Long-term outcomes following traumatic brain injury (TBI) correlate with initial head injury severity and other acute factors. Hospital-acquired pneumonia (HAP) is a common complication in TBI. Limited information exists regarding the significance of infectious complications on long-term outcomes after TBI. We sought to characterize risks associated with HAP on outcomes 5 years after TBI. This study involved data from the merger of an institutional trauma registry and the Traumatic Brain Injury Model Systems outcome data. Individuals with severe head injuries (Abbreviated Injury Scale [AIS] score ≥ 4) who survived to rehabilitation were analyzed. Primary outcome was Glasgow Outcome Scale-Extended (GOSE) at 1, 2, and 5 years. GOSE was dichotomized into low (GOSE score GOSE score ≥ 6). Logistic regression was used to determine adjusted odds of low GOSE score associated with HAP after controlling for age, sex, head and overall injury severity, cranial surgery, Glasgow Coma Scale (GCS) score, ventilation days, and other important confounders. A general estimating equation model was used to analyze all outcome observations simultaneously while controlling for within-patient correlation. A total of 141 individuals met inclusion criteria, with a 30% incidence of HAP. Individuals with and without HAP had similar demographic profiles, presenting vitals, head injury severity, and prevalence of cranial surgery. Individuals with HAP had lower presenting GCS score. Logistic regression demonstrated that HAP was independently associated with low GOSE scores at follow-up (1 year: odds ratio [OR], 6.39; 95% confidence interval [CI], 1.76-23.14; p = 0.005) (2 years: OR, 7.30; 95% CI, 1.87-27.89; p = 0.004) (5-years: OR, 6.89; 95% CI, 1.42-33.39; p = 0.017). Stratifying by GCS score of 8 or lower and early intubation, HAP remained a significant independent predictor of low GOSE score in all strata. In the general estimating equation model, HAP continued to be an independent

  2. Hospital Acquired Pneumonia is an Independent Predictor of Poor Global Outcome in Severe Traumatic Brain Injury up to 5 Years after Discharge

    Science.gov (United States)

    Kesinger, Matthew R.; Kumar, Raj G.; Wagner, Amy K.; Puyana, Juan C.; Peitzman, Andrew P.; Billiar, Timothy R.; Sperry, Jason L.

    2016-01-01

    Objectives Long-term outcomes following traumatic brain injury (TBI) correlate with initial head injury severity and other acute factors. Hospital-acquired pneumonia (HAP) is a common complication in TBI. Little information exists regarding the significance of infectious complications on long-term outcomes post-TBI. We sought to characterize risks associated with HAP on outcomes 5 years post-TBI. Methods Ddata from the merger of an institutional trauma registry and the TBI Model Systems outcome data. Individuals with severe head injuries (Abbreviated Injury Scale≥4), who survived to rehabilitation were analyzed. Primary outcome was Glasgow Outcome Scaled-Extended (GOSE) at 1, 2, and 5 years. GOSE was dichotomized into LOW (GOSEGOSE≥6). Logistic regression was utilized to determine adjusted odds of LOW-GOSE associated with HAP after controlling for age, sex, head and overall injury severity, cranial surgery, Glasgow Coma Scale (GCS), ventilation days, and other important confounders. A general estimating equation (GEE) model was used to analyze all outcome observations simultaneously while controlling for within-patient correlation. Results A total of 141 individuals met inclusion criteria, with a 30% incidence of HAP. Individuals with and without HAP had similar demographic profiles, presenting vitals, head injury severity, and prevalence of cranial surgery. Individuals with HAP had lower presenting GCS. Logistic regression demonstrated that HAP was independently associated with LOW-GOSE scores at follow-up (1year: OR=6.39, 95%CI: 1.76-23.14, p=0.005; 2-years: OR=7.30, 95%CI 1.87-27.89, p=0.004; 5-years: OR=6.89, 95%CI: 1.42-33.39, p=0.017). Stratifying by GCS≤8 and early intubation, HAP remained a significant independent predictor of LOW-GOSE in all strata. In the GEE model, HAP continued to be an independent predictor of LOW-GOSE (OR: 4.59; 95%CI: 1.82-11.60′ p=0.001). Conclusion HAP is independently associated with poor outcomes in severe-TBI extending 5

  3. I wish I had (not) taken a gap-year? The psychological and attainment outcomes of different post-school pathways.

    Science.gov (United States)

    Parker, Philip D; Thoemmes, Felix; Duineveld, Jasper J; Salmela-Aro, Katariina

    2015-03-01

    Existing gap-year research indicates a number of benefits of a gap-year at the end of school and before university enrollment. Life span theory of control, however, suggests that direct goal investment, rather than delay, at developmental transitions is associated with more adaptive outcomes. Comparing these perspectives, the authors undertook 2 studies: 1 in Finland (N = 384, waves = 3) and 1 in Australia (N = 2,259, waves = 5) both with an initial time wave in the last year of high school. The authors explored the effects of a gap-year on both psychological and attainment outcomes using an extensive propensity score matching technique. The Finnish study found no difference in growth in goal commitment, effort, expectations of attainment and strain, or in actual university enrollment in those planning to enter university directly versus those who plan to take a gap-year. The Australian study found no difference in growth in outlooks for the future and career prospects, and life satisfaction between gap-year youth and direct university entrants. However, the study did find that gap-year students were more likely to drop out of a university degree. Implication for theory and practice are discussed. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  4. Merkel Cell Carcinoma Analysis of Outcomes: A 30-Year Experience.

    Directory of Open Access Journals (Sweden)

    Evan Liang

    Full Text Available Merkel cell carcinoma (MCC is an aggressive cutaneous malignancy with poor prognosis. Limited data exists to guide treatment decisions. Here we report on our institutional experience and outcomes treating patients with MCC.A database search (1984-2014 of patients treated at the University of Wisconsin Hospital and Clinics was used to identify patients with histologically confirmed MCC. Patient, tumor, and treatment characteristics were examined via review of medical records. Statistical analyses were performed to assess outcomes and associated prognostic factors.A total of 87 patients with MCC were identified with a median follow-up of 17 months (mean: 38, range: 0-210 months. Two and five-year overall survival rates were 53.9% and 32.8%, respectively. Recurrence was documented in 31.0% of patients (85.2% locoregional, 48.1% distant and 33.3% both. Patients with a history of immunosuppression exhibited significantly worse survival (hazard ratio, 2.01; 95% CI, 1.1-3.7 when compared to immune-competent individuals. The head and neck region was the most common location of primary lesion (N=49 followed by the extremities (N=31. Upper extremity primaries predicted significantly better overall survival (hazard ratio, 0.48; 95% CI, 0.23-0.99 while lower extremity primaries did not have significantly better results (hazard ratio, 0.5; 95% CI, 0.21-1.2 in comparison to head and neck site of primary. Nodal involvement (hazard ratio, 2.95; 95% CI, 1.5-5.79 was also a negative prognostic factor associated with poor overall survival when compared with clinically node negative patients. Primary tumor size > 2 cm (hazard ratio, 1.76; 95% CI, 0.91-3.4 was not associated with survival.This study highlights the role of various factors in determining prognosis of Merkel cell carcinoma; history of immunosuppression, nodal involvement, and head/neck primary predicted worse overall survival. These findings suggest that improvements in both distant and locoregionally

  5. Excellent Survival and Good Outcomes at 15 Years Using the Press-Fit Condylar Sigma Total Knee Arthroplasty.

    Science.gov (United States)

    Oliver, William M; Arthur, Calum H C; Wood, Alexander M; Clayton, Robert A E; Brenkel, Ivan J; Walmsley, Philip

    2018-03-27

    We report 15-year survival, clinical, and radiographic follow-up data for the Press-Fit Condylar Sigma total knee arthroplasty. Between October 1998 and October 1999, 235 consecutive TKAs were performed in 203 patients. Patients were reviewed at a specialist nurse-led clinic before surgery and at 5, 8-10, and 15 years postoperatively. Clinical outcomes, including Knee Society Score, were recorded prospectively at each clinic visit, and radiographs were obtained. Of our initial cohort, 99 patients (118 knees) were alive at 15 years, and 31 patients (34 knees) were lost to follow-up. Thirteen knees (5.5%) were revised; 5 (2.1%) for infection, 7 (3%) for instability, and 1 (0.4%) for aseptic loosening. Cumulative survival with the end point of revision for any reason was 92.3% at 15 years and with revision for aseptic failure as the end point was 94.4%. The mean Knee Society Score knee score was 77.4 (33-99) at 15 years, compared with 31.7 (2-62) preoperatively. Of 71 surviving knees for which X-rays were available, 12 (16.9%) had radiolucent lines and 1 (1.4%) demonstrated clear radiographic evidence of loosening. The Press-Fit Condylar Sigma total knee arthroplasty represents a durable, effective option for patients undergoing knee arthroplasty, with excellent survival and good clinical and radiographic outcomes at 15 years. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Prostate cancer outcomes in France: treatments, adverse effects and two-year mortality

    Science.gov (United States)

    2014-01-01

    Background This very large population-based study investigated outcomes after a diagnosis of prostate cancer (PCa) in terms of mortality rates, treatments and adverse effects. Methods Among the 11 million men aged 40 years and over covered by the general national health insurance scheme, those with newly managed PCa in 2009 were followed for two years based on data from the national health insurance information system (SNIIRAM). Patients were identified using hospitalisation diagnoses and specific refunds related to PCa and PCa treatments. Adverse effects of PCa treatments were identified by using hospital diagnoses, specific procedures and drug refunds. Results The age-standardised two-year all-cause mortality rate among the 43,460 men included in the study was 8.4%, twice that of all men aged 40 years and over. Among the 36,734 two-year survivors, 38% had undergone prostatectomy, 36% had been treated by hormone therapy, 29% by radiotherapy, 3% by brachytherapy and 20% were not treated. The frequency of treatment-related adverse effects varied according to age and type of treatment. Among men between 50 and 69 years of age treated by prostatectomy alone, 61% were treated for erectile dysfunction and 24% were treated for urinary disorders. The frequency of treatment for these disorders decreased during the second year compared to the first year (erectile dysfunction: 41% vs 53%, urinary disorders: 9% vs 20%). The frequencies of these treatments among men treated by external beam radiotherapy alone were 7% and 14%, respectively. Among men between 50 and 69 years with treated PCa, 46% received treatments for erectile dysfunction and 22% for urinary disorders. For controls without PCa but treated surgically for benign prostatic hyperplasia, these frequencies were 1.5% and 6.0%, respectively. Conclusions We report high survival rates two years after a diagnosis of PCa, but a high frequency of PCa treatment-related adverse effects. These frequencies remain

  7. Integration of a neutral absorber for the LHC point 8

    CERN Document Server

    Santamaria, A; Alemany, R; Burkhardt, H; Cerutti, F

    2014-01-01

    The LHCb detector will be upgraded during the second long shutdown (LS2) of the LHC machine, in order to increase its statistical precision significantly. The upgraded LHCb foresees a peak luminosity of LHL = 1-21033cm-2s-11, with a pileup of ~5. This represents ten times more luminosity and five times more pile up than in the present LHC. With these conditions, the pp-collisions and beam losses will produce a non-negligeable beam-induced energy deposition in the interaction region. More precisely, studies [1] have shown that the energy deposition will especially increase on the D2 recombination dipole, which could bring them close to their safety thresholds. To avoid this, the placement of a minimal neutral absorber has been proposed. This absorber will have the same role as the TAN in the high luminosity Interaction Regions (IR) 1 and 5. This study shows the possible dimensions and location of this absorber, and how it would reduce both the peak power density and total heat load.

  8. Distributions of 12 elements on 64 absorbers from simulated Hanford Neutralized Current Acid Waste (NCAW)

    International Nuclear Information System (INIS)

    Svitra, Z.V.; Bowen, S.M.; Marsh, S.F.

    1994-12-01

    As part of the Hanford Tank Waste Remediation System program at Los Alamos, we evaluated 64 commercially available or experimental absorber materials for their ability to remove hazardous components from high-level waste. These absorbers included cation and anion exchange resins, inorganic exchangers, composite absorbers, and a series of liquid extractants sorbed on porous support-beads. We tested these absorbers with a solution that simulates Hanford neutralized current acid waste (NCAW) (pH 14.2). To this simulant solution we added the appropriate radionuclides and used gamma spectrometry to measure fission products (Cs, Sr, Tc, and Y) and matrix elements (Cr, Co, Fe, Mn, Ni, V, Zn, and Zr). For each of 768 element/absorber combinations, we measured distribution coefficients for dynamic contact periods of 30 min, 2 h, and 6 h to obtain information about sorption kinetics. On the basis of these 2304 measured distribution coefficients, we determined that many of the tested absorbers may be suitable for processing NCAW solutions

  9. Comments on liquid hydrogen absorbers for MICE

    International Nuclear Information System (INIS)

    Green, Michael A.

    2003-01-01

    This report describes the heat transfer problems associated with a liquid hydrogen absorber for the MICE experiment. This report describes a technique for modeling heat transfer from the outside world, to the absorber case and in its vacuum vessel, to the hydrogen and then into helium gas at 14 K. Also presented are the equation for free convection cooling of the liquid hydrogen in the absorber

  10. Impact Testing and Simulation of a Sinusoid Foam Sandwich Energy Absorber

    Science.gov (United States)

    Jackson, Karen E.; Fasanella, Edwin L; Littell, Justin D.

    2015-01-01

    A sinusoidal-shaped foam sandwich energy absorber was developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research project. The energy absorber, designated the "sinusoid," consisted of hybrid carbon- Kevlar® plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical or crush direction, and a closed-cell ELFOAM(TradeMark) P200 polyisocyanurate (2.0-lb/ft3) foam core. The design goal for the energy absorber was to achieve an average floor-level acceleration of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in the design were assessed through quasi-static and dynamic crush testing of component specimens. Once the design was finalized, a 5-ft-long subfloor beam was fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorber prior to retrofit into TRACT 2. Finite element models were developed of all test articles and simulations were performed using LSDYNA ®, a commercial nonlinear explicit transient dynamic finite element code. Test analysis results are presented for the sinusoid foam sandwich energy absorber as comparisons of load-displacement and acceleration-time-history responses, as well as predicted and experimental structural deformations and progressive damage for each evaluation level (component testing through barrel section drop testing).

  11. ATLAS Barrel Hadron Calorimeter: general manufacturing concepts for 300000 absorber plates mass production

    International Nuclear Information System (INIS)

    Alikov, B.A.; Budagov, Yu.A.; Bylinkin, P.M

    1998-01-01

    We summarize a 4-year (1994-1997) experience of design and research efforts which led us to the solution of 2 important tasks of a principal significance for precision assembly of one of major elements of ATLAS, - its Hadron Barrel Tile Calorimeter. These tasks were: - to develop the high tolerances (50-100 microns) technology for about 300000 units of calorimeter nuclear absorber plates mass production, - to choose the best manufacturer(s) able to satisfy shop drawings demands in a reasonable balance with some other significant criteria: production period, price acceptable geography location (transport expenses), available storage area and access ways, reliable quality control etc. For the best absorbers producers our final choice was the TATRA PLANT (Czech Republic) for 1.6 m long plates stamping (40800 units) with Argonne punching die and the MINSK TRACTOR PLANT (Belarus Republic) for smaller size plates stamping (about 240000 units). We exclude noticeable (more than 1% of the day production) tolerances violations by the specially developed QUALITY CONTROL Program

  12. Experimental study on the ionizing radiation field in absorbers irradiated by the 0.8 GeV and 1.2 GeV electrons

    International Nuclear Information System (INIS)

    Ambrosimov, V.K.; Kalmykov, N.N.; Kovalenko, G.D.

    1987-01-01

    The measurement results of spatial distribution of aluminium detector energy release and radioactivity in absorbers irradiated by 0.8 and 1.2 GeV electrons are given. Absorbers are made of aluminium, iron and lead, 30x30 cm size across the thickness is about 18 radiation length units. Thermoluminescence dosimeters LiF and radiochromium film dosimeters have been used to measure energy release. Induced activity of 18 F and 24 Na nuclides is determined in aluminium detectors. The experimental data are compared with the results of calculation carried out by the Monte-Carlo method

  13. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  14. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  15. Laser Beam Melting of Alumina: Effect of Absorber Additions

    Science.gov (United States)

    Moniz, Liliana; Colin, Christophe; Bartout, Jean-Dominique; Terki, Karim; Berger, Marie-Hélène

    2018-03-01

    Ceramic laser beam melting offers new manufacturing possibilities for complex refractory structures. Poor absorptivity in near infra-red wavelengths of oxide ceramics is overcome with absorber addition to ceramic powders. Absorbers affect powder bed densities and geometrical stability of melted tracks. Optimum absorber content is defined for Al2O3 by minimizing powder bed porosity, maximizing melting pool geometrical stability and limiting shrinkage. Widest stability fields are obtained with addition of 0.1 wt.% C and 0.5 wt.% β-SiC. Absorption coefficient values of Beer-Lambert law follow stability trends: they increase with C additions, whereas with β-SiC, a maximum is reached for 0.5 wt.%. Powder particle ejections are also identified. Compared to metallic materials, this ejection phenomenon can no longer be neglected when establishing a three-dimensional manufacturing strategy.

  16. Beam test of ferrite absorber in TRISTAN MR

    International Nuclear Information System (INIS)

    Tajima, T.; Asano, K.; Furuya, T.; Ishi, Y.; Kijima, Y.; Mitsunobu, S.; Sennyu, K.; Takahashi, T.

    1996-06-01

    A study on the effect of beams on the ferrite absorber was performed using TRISTAN MR. The tested absorber consists of a 300 mm-diam. copper pipe with 4 mm-thick ferrite inner layer, which was fabricated with Hot Isostatic Press (HIP) technique. No spark, damage, or degradation were observed up to the highest available single bunch current of 4.4 mA, i.e. 2.8x10 11 electrons per bunch, which is 8.5 times higher than that of KEKB low energy ring. The loss factor showed significant increase with bunch shortening, e.g. 2.6 V/pC at 4 mm was about 40% higher than the value predicted by the calculation assuming Gaussian bunch and no incoming power from outside of the chamber. (author)

  17. Outcomes associated with early post-traumatic osteoarthritis and other negative health consequences 3-10 years following knee joint injury in youth sport.

    Science.gov (United States)

    Whittaker, J L; Woodhouse, L J; Nettel-Aguirre, A; Emery, C A

    2015-07-01

    Post-traumatic osteoarthritis (PTOA) commonly affects the knee joint. Although the risk of PTOA substantially increases post-joint injury, there is little research examining PTOA outcomes early in the period between joint injury and disease onset. Improved understanding of this interval would inform secondary prevention strategies aimed at preventing and/or delaying PTOA progression. This study examines the association between sport-related knee injury and outcomes related to development of PTOA, 3-10 years post-injury. This preliminary analysis of the first year of a historical cohort study includes 100 (15-26 years) individuals. Fifty with a sport-related intra-articular knee injury sustained 3-10 years previously and 50 uninjured age, sex and sport matched controls. The primary outcome was the 'Symptoms' sub-scale of the Knee Osteoarthritis and Injury Outcome Score (KOOS). Secondary outcomes included; the remaining KOOS subscales, body mass index (BMI), hip abductor/adductor and knee extensor/flexor strength, estimated aerobic capacity (VO2max) and performance scores on three dynamic balance tests. Descriptive statistics (mean within-pair difference; 95% Confidence interval (CI) and conditional odds ratio (OR, 95% CI; BMI) were used to compare study groups. Injured participants demonstrated poorer KOOS outcomes [symptoms -9.4 (-13.6, -5.2), pain -4.0 (-6.8, -1.2), quality-of-life -8.0 (-11.0, -5.1), daily living -3.0 (-5.0, -1.1) and sport/recreation -6.9 (-9.9, -3.8)], were 3.75 times (95% CI 1.24, 11.3) more likely to be overweight/obese and had lower triple single leg hop scores compared to controls. No significant group differences existed for remaining balance scores, estimated VO2max, hip or knee strength ratios or side-to-side difference in hip abductor/adductor or quadricep/hamstring strength. This study provides preliminary evidence that youth/young adults following sport-related knee injury report more symptoms and poorer function, and are at

  18. Outcome of lupus nephritis in childhood onset SLE in North and Central India: single-centre experience over 25 years.

    Science.gov (United States)

    Srivastava, P; Abujam, B; Misra, R; Lawrence, A; Agarwal, V; Aggarwal, A

    2016-04-01

    Childhood SLE (cSLE) has a higher prevalence of lupus nephritis (LN), and there are ethnic variations in response to treatment as well as outcome of LN. There are limited data on long-term outcome of LN in cSLE from the Indian subcontinent. Retrospective analysis of case records of patients with cSLE (satisfying revised American College of Rheumatology (ACR) 1997 criteria for diagnosis) and age of onset Collaborating Clinics (SLICC)/ACR damage score was 0.79 ± 1.13. Actuarial ESRD-free survival at five, 10 and 15 years was 91.1%, 79% and 76.2%, and five-, 10- and 15-year renal survival was 93.8%, 87.1% and 84%, respectively. Although multiple factors individually predicted poor outcome (death/ESRD), only raised serum creatinine at onset (R square = 0.65, p ≤ 0.0001) and damage accrual (R square = 0.62, p ≤ 0.0001) remained significant on multivariate analysis. Eleven (8.2%) children died during the follow-up period, and infections were the leading cause of mortality. Long-term outcome of LN in cSLE in our cohort was better than previous reports from India. However, a high rate of major infection still remains the leading cause of mortality. © The Author(s) 2015.

  19. Waters of Hydration of Cupric Hydrates: A Comparison between Heating and Absorbance Methods

    Science.gov (United States)

    Barlag, Rebecca; Nyasulu, Frazier

    2011-01-01

    The empirical formulas of four cupric hydrates are determined by measuring the absorbance in aqueous solution. The Beer-Lambert Law is verified by constructing a calibration curve of absorbance versus known Cu[superscript 2+](aq) concentration. A solution of the unknown hydrate is prepared by using 0.2-0.3 g of hydrate, and water is added such…

  20. Experiences of weight teasing in adolescence and weight-related outcomes in adulthood: A 15-year longitudinal study.

    Science.gov (United States)

    Puhl, Rebecca M; Wall, Melanie M; Chen, Chen; Bryn Austin, S; Eisenberg, Marla E; Neumark-Sztainer, Dianne

    2017-07-01

    Weight-based teasing is common among youth, but little is known about its long-term impact on health outcomes. We aimed to 1) identify whether weight-based teasing in adolescence predicts adverse eating and weight-related outcomes 15years later; and 2) determine whether teasing source (peers or family) affects these outcomes. Data were collected from Project EAT-IV (Eating and Activity in Teens and Young Adults) (N=1830), a longitudinal cohort study that followed a diverse sample of adolescents from 1999 (baseline) to 2015 (follow-up). Weight-based teasing at baseline was examined as a predictor of weight status, binge eating, dieting, eating as a coping strategy, unhealthy weight control, and body image at 15-year follow-up. After adjusting for demographic covariates and baseline body mass index (BMI), weight-based teasing in adolescence predicted higher BMI and obesity 15years later. For women, these longitudinal associations occurred across peer and family-based teasing sources, but for men, only peer-based teasing predicted higher BMI. The same pattern emerged for adverse eating outcomes; weight-based teasing from peers and family during adolescence predicted binge eating, unhealthy weight control, eating to cope, poor body image, and recent dieting in women 15years later. For men, teasing had fewer longitudinal associations. Taken together, this study shows that weight-based teasing in adolescence predicts obesity and adverse eating behaviors well into adulthood, with differences across gender and teasing source. Findings underscore the importance of addressing weight-based teasing in educational and health initiatives, and including the family environment as a target of anti-bullying intervention, especially for girls. Copyright © 2017 Elsevier Inc. All rights reserved.