WorldWideScience

Sample records for absolute threshold technique

  1. Near threshold absolute TDCS: First results

    International Nuclear Information System (INIS)

    Roesel, T.; Schlemmer, P.; Roeder, J.; Frost, L.; Jung, K.; Ehrhardt, H.

    1992-01-01

    A new method, and first results for an impact energy 2 eV above the threshold of ionisation of helium, are presented for the measurement of absolute triple differential cross sections (TDCS) in a crossed beam experiment. The method is based upon measurement of beam/target overlap densities using known absolute total ionisation cross sections and of detection efficiencies using known absolute double differential cross sections (DDCS). For the present work the necessary absolute DDCS for 1 eV electrons had also to be measured. Results are presented for several different coplanar kinematics and are compared with recent DWBA calculations. (orig.)

  2. Assessment of infarct size by positron emission tomography and [18F]2-fluoro-2-deoxy-D-glucose: a new absolute threshold technique

    International Nuclear Information System (INIS)

    Chareonthaitawee, P.; Iozzo, Patricia; Schaefers, K.; Stegger, L.; Baker, C.S.R.; Camici, Paolo G.; Rimoldi, Ornella; Turkheimer, F.; Banner, N.R.; Yacoub, Magdi; Bonser, Robert S.

    2002-01-01

    Along with hibernating myocardium, infarct size is a critical term in the progression of left ventricular remodelling and congestive heart failure. Both infarcted and hibernating myocardium determine changes in remote non-ischaemic tissue. This study was designed to test the accuracy of a new technique to quantify infarct size using positron emission tomography (PET) with [ 18 F]2-fluoro-2-deoxy-D-glucose (FDG). Studies were carried out in (a) nine pigs with acute myocardial infarction (two sham-operated), produced by a 90-min occlusion of the circumflex coronary artery followed by a 4-h reperfusion, and (b) humans (six patients with ischaemic cardiomyopathy awaiting cardiac transplantation and five normal volunteers). In both animals and patients, myocardial FDG uptake was measured by PET during hyperinsulinaemic-euglycaemic clamp. Infarct size was quantified by an absolute threshold of tracer uptake obtained from the parametric (voxel-by-voxel) image of the metabolic rate of FDG. PET infarct size estimates were compared with independent ex vivo planimetric measurements of the explanted swine and patient hearts (at transplantation) after staining with triphenyltetrazolium chloride. There was good agreement between the planimetric and PET infarct size estimates both in pigs (n=9; r=0.96, y=0.94x +0.64, SEE=0.10, P<0.0001) and in humans (n=11; r=0.94, y=0.72x +2.93, SEE=0.09, P<0.0001). This study demonstrates the feasibility and accuracy of this PET method in estimating infarct size both in a model of reperfused acute myocardial infarction and in chronic ischaemic cardiomyopathy, although larger studies are needed to confirm these findings. (orig.)

  3. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    Science.gov (United States)

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises,…

  4. Absolute calibration technique for spontaneous fission sources

    International Nuclear Information System (INIS)

    Zucker, M.S.; Karpf, E.

    1984-01-01

    An absolute calibration technique for a spontaneously fissioning nuclide (which involves no arbitrary parameters) allows unique determination of the detector efficiency for that nuclide, hence of the fission source strength

  5. MEAN OF MEDIAN ABSOLUTE DERIVATION TECHNIQUE MEAN ...

    African Journals Online (AJOL)

    eobe

    development of mean of median absolute derivation technique based on the based on the based on .... of noise mean to estimate the speckle noise variance. Noise mean property ..... Foraging Optimization,” International Journal of. Advanced ...

  6. The absolute threshold of colour vision in the horse.

    Directory of Open Access Journals (Sweden)

    Lina S V Roth

    Full Text Available Arrhythmic mammals are active both during day and night if they are allowed. The arrhythmic horses are in possession of one of the largest terrestrial animal eyes and the purpose of this study is to reveal whether their eye is sensitive enough to see colours at night. During the day horses are known to have dichromatic colour vision. To disclose whether they can discriminate colours in dim light a behavioural dual choice experiment was performed. We started the training and testing at daylight intensities and the horses continued to choose correctly at a high frequency down to light intensities corresponding to moonlight. One Shetland pony mare, was able to discriminate colours at 0.08 cd/m(2, while a half blood gelding, still discriminated colours at 0.02 cd/m(2. For comparison, the colour vision limit for several human subjects tested in the very same experiment was also 0.02 cd/m(2. Hence, the threshold of colour vision for the horse that performed best was similar to that of the humans. The behavioural results are in line with calculations of the sensitivity of cone vision where the horse eye and human eye again are similar. The advantage of the large eye of the horse lies not in colour vision at night, but probably instead in achromatic tasks where presumably signal summation enhances sensitivity.

  7. Absolute 3PO triple differential cross sections for electron-helium Wannier threshold ionisation

    International Nuclear Information System (INIS)

    Carruthers, D.R.J.; Crothers, D.S.F.

    1992-01-01

    The uniform semiclassical approximation of Crothers is employed to find a final-state 3 P O wave function for threshold electron impact ionisation of helium. The Kohn variational principle is applied perturbatively to evaluate the scattering amplitude and hence the absolute 3 P O contribution to the triple differential cross sections. These plus the previous absolute singlet results of Crothers are compared favourably with the relative experimental results of Selles et al. (orig.)

  8. The dual rod system of amphibians supports colour discrimination at the absolute visual threshold.

    Science.gov (United States)

    Yovanovich, Carola A M; Koskela, Sanna M; Nevala, Noora; Kondrashev, Sergei L; Kelber, Almut; Donner, Kristian

    2017-04-05

    The presence of two spectrally different kinds of rod photoreceptors in amphibians has been hypothesized to enable purely rod-based colour vision at very low light levels. The hypothesis has never been properly tested, so we performed three behavioural experiments at different light intensities with toads ( Bufo ) and frogs ( Rana ) to determine the thresholds for colour discrimination. The thresholds of toads were different in mate choice and prey-catching tasks, suggesting that the differential sensitivities of different spectral cone types as well as task-specific factors set limits for the use of colour in these behavioural contexts. In neither task was there any indication of rod-based colour discrimination. By contrast, frogs performing phototactic jumping were able to distinguish blue from green light down to the absolute visual threshold, where vision relies only on rod signals. The remarkable sensitivity of this mechanism comparing signals from the two spectrally different rod types approaches theoretical limits set by photon fluctuations and intrinsic noise. Together, the results indicate that different pathways are involved in processing colour cues depending on the ecological relevance of this information for each task.This article is part of the themed issue 'Vision in dim light'. © 2017 The Authors.

  9. A probabilistic Poisson-based model accounts for an extensive set of absolute auditory threshold measurements.

    Science.gov (United States)

    Heil, Peter; Matysiak, Artur; Neubauer, Heinrich

    2017-09-01

    Thresholds for detecting sounds in quiet decrease with increasing sound duration in every species studied. The neural mechanisms underlying this trade-off, often referred to as temporal integration, are not fully understood. Here, we probe the human auditory system with a large set of tone stimuli differing in duration, shape of the temporal amplitude envelope, duration of silent gaps between bursts, and frequency. Duration was varied by varying the plateau duration of plateau-burst (PB) stimuli, the duration of the onsets and offsets of onset-offset (OO) stimuli, and the number of identical bursts of multiple-burst (MB) stimuli. Absolute thresholds for a large number of ears (>230) were measured using a 3-interval-3-alternative forced choice (3I-3AFC) procedure. Thresholds decreased with increasing sound duration in a manner that depended on the temporal envelope. Most commonly, thresholds for MB stimuli were highest followed by thresholds for OO and PB stimuli of corresponding durations. Differences in the thresholds for MB and OO stimuli and in the thresholds for MB and PB stimuli, however, varied widely across ears, were negative in some ears, and were tightly correlated. We show that the variation and correlation of MB-OO and MB-PB threshold differences are linked to threshold microstructure, which affects the relative detectability of the sidebands of the MB stimuli and affects estimates of the bandwidth of auditory filters. We also found that thresholds for MB stimuli increased with increasing duration of the silent gaps between bursts. We propose a new model and show that it accurately accounts for our results and does so considerably better than a leaky-integrator-of-intensity model and a probabilistic model proposed by others. Our model is based on the assumption that sensory events are generated by a Poisson point process with a low rate in the absence of stimulation and higher, time-varying rates in the presence of stimulation. A subject in a 3I-3AFC

  10. Relative and absolute test-retest reliabilities of pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars

    2018-04-25

    Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC

  11. Color image Segmentation using automatic thresholding techniques

    International Nuclear Information System (INIS)

    Harrabi, R.; Ben Braiek, E.

    2011-01-01

    In this paper, entropy and between-class variance based thresholding methods for color images segmentation are studied. The maximization of the between-class variance (MVI) and the entropy (ME) have been used as a criterion functions to determine an optimal threshold to segment images into nearly homogenous regions. Segmentation results from the two methods are validated and the segmentation sensitivity for the test data available is evaluated, and a comparative study between these methods in different color spaces is presented. The experimental results demonstrate the superiority of the MVI method for color image segmentation.

  12. Absolute Paleointensity Techniques: Developments in the Last 10 Years (Invited)

    Science.gov (United States)

    Bowles, J. A.; Brown, M. C.

    2009-12-01

    The ability to determine variations in absolute intensity of the Earth’s paleomagnetic field has greatly enhanced our understanding of geodynamo processes, including secular variation and field reversals. Igneous rocks and baked clay artifacts that carry a thermal remanence (TRM) have allowed us to study field variations over timescales ranging from decades to billions of years. All absolute paleointensity techniques are fundamentally based on repeating the natural process by which the sample acquired its magnetization, i.e. a laboratory TRM is acquired in a controlled field, and the ratio of the natural TRM to that acquired in the laboratory is directly proportional to the ancient field. Techniques for recovering paleointensity have evolved since the 1930s from relatively unsophisticated (but revolutionary for their time) single step remagnetizations to the various complicated, multi-step procedures in use today. These procedures can be broadly grouped into two categories: 1) “Thellier-type” experiments that step-wise heat samples at a series of temperatures up to the maximum unblocking temperature of the sample, progressively removing the natural remanence (NRM) and acquiring a laboratory-induced TRM; and 2) “Shaw-type” experiments that combine alternating field demagnetization of the NRM and laboratory TRM with a single heating to a temperature above the sample’s Curie temperature, acquiring a total TRM in one step. Many modifications to these techniques have been developed over the years with the goal of identifying and/or accommodating non-ideal behavior, such as alteration and multi-domain (MD) remanence, which may lead to inaccurate paleofield estimates. From a technological standpoint, perhaps the most significant development in the last decade is the use of microwave (de)magnetization in both Thellier-type and Shaw-type experiments. By using microwaves to directly generate spin waves within the magnetic grains (rather than using phonons

  13. Absolute cross sections for photoionization of Xeq+ ions (1 ⩽ q ⩽ 5) at the 3d ionization threshold

    International Nuclear Information System (INIS)

    Schippers, S; Ricz, S; Buhr, T; Borovik, A Jr; Hellhund, J; Holste, K; Huber, K; Schäfer, H-J; Schury, D; Klumpp, S; Mertens, K; Martins, M; Flesch, R; Ulrich, G; Rühl, E; Jahnke, T; Lower, J; Metz, D; Schmidt, L P H; Schöffler, M

    2014-01-01

    The photon-ion merged-beams technique has been employed at the new Photon-Ion spectrometer at PETRA III for measuring multiple photoionization of Xe q+ (q = 1–5) ions. Total ionization cross sections have been obtained on an absolute scale for the dominant ionization reactions of the type hν + Xe q+ → Xe r+ + (q − r)e − with product charge states q + 2 ⩽ r ⩽ q + 5. Prominent ionization features are observed in the photon-energy range 650–750 eV, which are associated with excitation or ionization of an inner-shell 3d electron. Single-configuration Dirac–Fock calculations agree quantitatively with the experimental cross sections for non-resonant photoabsorption, but fail to reproduce all details of the measured ionization resonance structures. (paper)

  14. An Overview of the Use of Absolute Dating Techniques in Ancient Construction Materials

    Directory of Open Access Journals (Sweden)

    Jorge Sanjurjo-Sánchez

    2016-04-01

    Full Text Available The reconstruction of the chronology of historical buildings is a tricky issue, as usually there are not historical documents that allow the assessment of construction phases, and some materials are hardly reliable for the use of dating techniques (e.g., stone. However, in the last two decades, important advances on the use of absolute dating methods on building materials have increased the possibilities of reconstructing building chronologies, although some advances are still scarcely known among archaeologists and architects. Recent studies performed on several kinds of mortars, fired bricks, mud-bricks, and even stone surfaces have shown that it is possible to date them. Both radiocarbon and luminescence dating have been the most frequently used techniques but others such as archaeomagnetism can also be used in some cases. This paper intends to give an overview of the recent achievements on the use of absolute dating techniques for building materials.

  15. Ear surgery techniques results on hearing threshold improvement

    Directory of Open Access Journals (Sweden)

    Farhad Mokhtarinejad

    2013-01-01

    Full Text Available Background: Bone conduction (BC threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. Materials and Methods: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP and Total Ossicular Replacement Prosthesis (TORP. Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. Results: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05. Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. Conclusion: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced.

  16. A new iterative triclass thresholding technique in image segmentation.

    Science.gov (United States)

    Cai, Hongmin; Yang, Zhong; Cao, Xinhua; Xia, Weiming; Xu, Xiaoyin

    2014-03-01

    We present a new method in image segmentation that is based on Otsu's method but iteratively searches for subregions of the image for segmentation, instead of treating the full image as a whole region for processing. The iterative method starts with Otsu's threshold and computes the mean values of the two classes as separated by the threshold. Based on the Otsu's threshold and the two mean values, the method separates the image into three classes instead of two as the standard Otsu's method does. The first two classes are determined as the foreground and background and they will not be processed further. The third class is denoted as a to-be-determined (TBD) region that is processed at next iteration. At the succeeding iteration, Otsu's method is applied on the TBD region to calculate a new threshold and two class means and the TBD region is again separated into three classes, namely, foreground, background, and a new TBD region, which by definition is smaller than the previous TBD regions. Then, the new TBD region is processed in the similar manner. The process stops when the Otsu's thresholds calculated between two iterations is less than a preset threshold. Then, all the intermediate foreground and background regions are, respectively, combined to create the final segmentation result. Tests on synthetic and real images showed that the new iterative method can achieve better performance than the standard Otsu's method in many challenging cases, such as identifying weak objects and revealing fine structures of complex objects while the added computational cost is minimal.

  17. Absolute quantification of Bovine Viral Diarrhea Virus (BVDV) RNA by the digital PCR technique

    Science.gov (United States)

    Flatschart, R. B.; Almeida, D. O.; Heinemann, M. B.; Medeiros, M. N.; Granjeiro, J. M.; Folgueras-Flatschart, A. V.

    2015-01-01

    The quality control of cell lines used in research and industry is critical to ensure confidence in experimental results and to guarantee the safety of biopharmaceuticals to consumers. The BVDV is a common adventitious agent in many cell lines. We preliminarly evaluate the use of Digital Droplet PCR (ddPCR) for the detection and enumeration of genome copies of BVDV in cell culture and on FBS. The application of a commercial Real-Time PCR kit with the ddPCR technique was successful on different matrices. The technique allowed the absolute quantification of the genome without the use of calibration standards, suggesting its promising application on the development of reference materials for quantification of nucleic acids.

  18. Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow

    Science.gov (United States)

    Diop, Mamadou; Tichauer, Kenneth M.; Elliott, Jonathan T.; Migueis, Mark; Lee, Ting-Yim; St. Lawrence, Keith

    2010-02-01

    A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF). Since current non-invasive bedside methods can only indirectly assess blood flow, the goal of this research was to develop an optical technique for measuring absolute CBF. A time-resolved near-infrared (NIR) apparatus was built and its ability to accurately measure changes in optical properties was demonstrated in tissue-mimicking phantoms. The time-resolved system was combined with a bolus-tracking method for measuring CBF using the dye indocyanine green (ICG) as an intravascular flow tracer. Cerebral blood flow was measured in newborn piglets and for comparison, CBF was concurrently measured using a previously developed continuous-wave NIR method. Measurements were acquired with both techniques under three conditions: normocapnia, hypercapnia and following occlusion of the carotid arteries. Mean CBF values (N = 3) acquired with the TR-NIR system were 31.9 +/- 11.7 ml/100g/min during occlusion, 39.7 +/- 1.6 ml/100g/min at normocapnia, and 58.8 +/- 9.9 ml/100g/min at hypercapnia. Results demonstrate that the developed TR-NIR technique has the sensitivity to measure changes in CBF; however, the CBF measurements were approximately 25% lower than the values obtained with the CW-NIRS technique.

  19. Technique for long and absolute distance measurement based on laser pulse repetition frequency sweeping

    Science.gov (United States)

    Castro Alves, D.; Abreu, Manuel; Cabral, A.; Jost, Michael; Rebordão, J. M.

    2017-11-01

    In this work we present a technique to perform long and absolute distance measurements based on mode-locked diode lasers. Using a Michelson interferometer, it is possible to produce an optical cross-correlation between laser pulses of the reference arm with the pulses from the measurement arm, adjusting externally their degree of overlap either changing the pulse repetition frequency (PRF) or the position of the reference arm mirror for two (or more) fixed frequencies. The correlation of the travelling pulses for precision distance measurements relies on ultra-short pulse durations, as the uncertainty associated to the method is dependent on the laser pulse width as well as on a highly stable PRF. Mode-locked Diode lasers are a very appealing technology for its inherent characteristics, associated to compactness, size and efficiency, constituting a positive trade-off with regard to other mode-locked laser sources. Nevertheless, main current drawback is the non-availability of frequency-stable laser diodes. The laser used is a monolithic mode-locked semiconductor quantum-dot (QD) laser. The laser PRF is locked to an external stabilized RF reference. In this work we will present some of the preliminary results and discuss the importance of the requirements related to laser PRF stability in the final metrology system accuracy.

  20. Comparative Study of Retinal Vessel Segmentation Based on Global Thresholding Techniques

    Directory of Open Access Journals (Sweden)

    Temitope Mapayi

    2015-01-01

    Full Text Available Due to noise from uneven contrast and illumination during acquisition process of retinal fundus images, the use of efficient preprocessing techniques is highly desirable to produce good retinal vessel segmentation results. This paper develops and compares the performance of different vessel segmentation techniques based on global thresholding using phase congruency and contrast limited adaptive histogram equalization (CLAHE for the preprocessing of the retinal images. The results obtained show that the combination of preprocessing technique, global thresholding, and postprocessing techniques must be carefully chosen to achieve a good segmentation performance.

  1. Tsunakawa-Shaw method - an absolute paleointensity technique using alternating field demagnetization

    Science.gov (United States)

    Yamamoto, Y.; Mochizuki, N.; Shibuya, H.; Tsunakawa, H.

    2015-12-01

    Among geologic materials volcanic rocks have been typically used to deduce an absolute paleointensity. In the last decade, however, there seems a becoming consensus that volcanic rocks are not so ideal materials due to such as magnetic grains other than non-interacting single domain particles. One approach to obtain a good paleointensity estimate from the rocks is to reduce and correct the non-ideality, suppress alterations in laboratory and screen out suspicious results. We have been working on a development and an application of the Tsunakawa-Shaw method, which has been previously called the LTD-DHT Shaw method. This method is an AF(alternating field)-based technique and thus a paleointensity is estimated using coercivity spectra. To reduce the non-ideality, all remanences undergo low-temperature demagnetization (LTD) before any AF demagnetizations to remove multi-domain like component. To correct the non-ideality, anhysteretic remanent magnetizations (ARMs) are imparted with their directions parallel to natural remanent magnetizations and laboratory-imparted thermoremanent magnetizations (TRMs) and measured before and after laboratory heating. These ARMs are used to correct remanence anisotropies, possible interaction effects originated from the non-ideal grains and TRM changes caused by laboratory alterations. TRMs are imparted by heating specimens above their Curie temperatures and then cooling to room temperature at once to simulate nature conditions. These cycles are done in vacuum to suppress alterations in laboratory. Obtained results are judged by selection criteria, including a check for validity of the ARM corrections.It has been demonstrated that successful paleointensities are obtained from historical lavas in Japan and Hawaii, and from baked clay samples from a reconstructed ancient kiln, with the flow-mean precision of 5-10%. In case of old volcanic rocks, however, the method does not necessarily seem to be perfect. We will summarize these points in

  2. Current measurement system utilizing cryogenic techniques for the absolute measurement of the magnetic flux quantum

    International Nuclear Information System (INIS)

    Endo, T.; Murayama, Y.; Sakamoto, Y.; Sakuraba, T.; Shiota, F.

    1989-01-01

    A series of systems composed of cryogenic devices such as a Josephson potentiometer and a cryogenic current comparator has been proposed and developed to precisely measure a current with any value up to 1 A. These systems will be used to measure the injected electrical energy with an uncertainty of the order of 0.01 ppm or less in the absolute measurement of the magnetic flux quantum by superconducting magnetic levitation. Some preliminary experiments are described

  3. Effects of pump recycling technique on stimulated Brillouin scattering threshold: a theoretical model.

    Science.gov (United States)

    Al-Asadi, H A; Al-Mansoori, M H; Ajiya, M; Hitam, S; Saripan, M I; Mahdi, M A

    2010-10-11

    We develop a theoretical model that can be used to predict stimulated Brillouin scattering (SBS) threshold in optical fibers that arises through the effect of Brillouin pump recycling technique. Obtained simulation results from our model are in close agreement with our experimental results. The developed model utilizes single mode optical fiber of different lengths as the Brillouin gain media. For 5-km long single mode fiber, the calculated threshold power for SBS is about 16 mW for conventional technique. This value is reduced to about 8 mW when the residual Brillouin pump is recycled at the end of the fiber. The decrement of SBS threshold is due to longer interaction lengths between Brillouin pump and Stokes wave.

  4. Digital evaluation of absolute marginal discrepancy: A comparison of ceramic crowns fabricated with conventional and digital techniques.

    Science.gov (United States)

    Liang, Shanshan; Yuan, Fusong; Luo, Xu; Yu, Zhuoren; Tang, Zhihui

    2018-04-05

    Marginal discrepancy is key to evaluating the accuracy of fixed dental prostheses. An improved method of evaluating marginal discrepancy is needed. The purpose of this in vitro study was to evaluate the absolute marginal discrepancy of ceramic crowns fabricated using conventional and digital methods with a digital method for the quantitative evaluation of absolute marginal discrepancy. The novel method was based on 3-dimensional scanning, iterative closest point registration techniques, and reverse engineering theory. Six standard tooth preparations for the right maxillary central incisor, right maxillary second premolar, right maxillary second molar, left mandibular lateral incisor, left mandibular first premolar, and left mandibular first molar were selected. Ten conventional ceramic crowns and 10 CEREC crowns were fabricated for each tooth preparation. A dental cast scanner was used to obtain 3-dimensional data of the preparations and ceramic crowns, and the data were compared with the "virtual seating" iterative closest point technique. Reverse engineering software used edge sharpening and other functional modules to extract the margins of the preparations and crowns. Finally, quantitative evaluation of the absolute marginal discrepancy of the ceramic crowns was obtained from the 2-dimensional cross-sectional straight-line distance between points on the margin of the ceramic crowns and the standard preparations based on the circumferential function module along the long axis. The absolute marginal discrepancy of the ceramic crowns fabricated using conventional methods was 115 ±15.2 μm, and 110 ±14.3 μm for those fabricated using the digital technique was. ANOVA showed no statistical difference between the 2 methods or among ceramic crowns for different teeth (P>.05). The digital quantitative evaluation method for the absolute marginal discrepancy of ceramic crowns was established. The evaluations determined that the absolute marginal discrepancies were

  5. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers

    Directory of Open Access Journals (Sweden)

    Francesco Dell’ Anna

    2018-04-01

    Full Text Available This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  6. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers.

    Science.gov (United States)

    Dell' Anna, Francesco; Dong, Tao; Li, Ping; Wen, Yumei; Azadmehr, Mehdi; Casu, Mario; Berg, Yngvar

    2018-04-17

    This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs) powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE) for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs) for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  7. Metal Artifacts Reduction of Pedicle Screws on Spine Computed Tomography Images Using Variable Thresholding Technique

    International Nuclear Information System (INIS)

    Kaewlek, T.; Koolpiruck, D.; Thongvigitmanee, S.; Mongkolsuk, M.; Chiewvit, P.; Thammakittiphan, S.

    2012-01-01

    Metal artifacts are one of significant problems in computed tomography (CT). The streak lines and air gaps arise from metal implants of orthopedic patients, such as prosthesis, dental bucket, and pedicle screws that cause incorrect diagnosis and local treatment planning. A common technique to suppressed artifacts is by adjusting windows, but those artifacts still remain on the images. To improve the detail of spine CT images, the variable thresholding technique is proposed in this paper. Three medical cases of spine CT images categorized by the severity of artifacts (screws head, one full screw, and two full screws) were investigated. Metal regions were segmented by k-mean clustering, then transformed into a sinogram domain. The metal sinogram was identified by the variable thresholding method, and then replaced the new estimated values by linear interpolation. The modified sinogram was reconstructed by the filtered back- projection algorithm, and added the metal region back to the modified reconstructed image in order to reproduce the final image. The image quality of the proposed technique, the automatic thresholding (Kalender) technique, and window adjustment technique was compared in term of noise and signal to noise ratio (SNR). The propose method can reduce metal artifacts between pedicle screws. After processing by our proposed technique, noise in the modified images is reduced (screws head 121.15 to73.83, one full screw 160.88 to 94.04, and two full screws 199.73 to 110.05 from the initial image) and SNR is increased (screws head 0.87 to 1.88, one full screw 1.54 to 2.82, and two full screws 0.32 to 0.41 from the initial image). The variable thresholding technique can identify the suitable boundary for restoring the missing data. The efficiency of the metal artifacts reduction is indicated on the case of partial and full pedicle screws. Our technique can improve the detail of spine CT images better than automatic thresholding (Kalender) technique, and

  8. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Empirical gradient threshold technique for automated segmentation across image modalities and cell lines.

    Science.gov (United States)

    Chalfoun, J; Majurski, M; Peskin, A; Breen, C; Bajcsy, P; Brady, M

    2015-10-01

    New microscopy technologies are enabling image acquisition of terabyte-sized data sets consisting of hundreds of thousands of images. In order to retrieve and analyze the biological information in these large data sets, segmentation is needed to detect the regions containing cells or cell colonies. Our work with hundreds of large images (each 21,000×21,000 pixels) requires a segmentation method that: (1) yields high segmentation accuracy, (2) is applicable to multiple cell lines with various densities of cells and cell colonies, and several imaging modalities, (3) can process large data sets in a timely manner, (4) has a low memory footprint and (5) has a small number of user-set parameters that do not require adjustment during the segmentation of large image sets. None of the currently available segmentation methods meet all these requirements. Segmentation based on image gradient thresholding is fast and has a low memory footprint. However, existing techniques that automate the selection of the gradient image threshold do not work across image modalities, multiple cell lines, and a wide range of foreground/background densities (requirement 2) and all failed the requirement for robust parameters that do not require re-adjustment with time (requirement 5). We present a novel and empirically derived image gradient threshold selection method for separating foreground and background pixels in an image that meets all the requirements listed above. We quantify the difference between our approach and existing ones in terms of accuracy, execution speed, memory usage and number of adjustable parameters on a reference data set. This reference data set consists of 501 validation images with manually determined segmentations and image sizes ranging from 0.36 Megapixels to 850 Megapixels. It includes four different cell lines and two image modalities: phase contrast and fluorescent. Our new technique, called Empirical Gradient Threshold (EGT), is derived from this reference

  10. Near threshold pulse shape discrimination techniques in scintillating CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Wu, S.C.; Yue, Q.; Lai, W.P.; Li, H.B.; Li, J.; Lin, S.T.; Liu, Y.; Singh, V.; Wang, M.Z.; Wong, H.T.; Xin, B.; Zhou, Z.Y.

    2004-01-01

    There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The key merit is the capability to differentiate nuclear recoil (nr) signatures from the background β/γ-events due to ambient radioactivity on the basis of their different pulse shapes. One of the major experimental challenges is to perform such pulse shape analysis in the statistics-limited domain where the light output is close to the detection threshold. Using data derived from measurements with low-energy γ's and nuclear recoils due to neutron elastic scatterings, it was verified that the pulse shapes between β/γ-events are different. Several methods of pulse shape discrimination (PSD) are studied, and their relative merits are compared. Full digitization of the pulse shapes is crucial to achieve good discrimination. Advanced software techniques with mean time, neural network and likelihood ratios give rise to satisfactory performance, and are superior to the conventional Double Charge method commonly applied at higher energies. PSD becomes effective starting at a light yield of about 20 photo-electrons. This corresponds to a detection threshold of about 5 keV electron-equivalence energy, or 40-50 keV recoil kinetic energy, in realistic experiments

  11. Image reconstruction with an adaptive threshold technique in electrical resistance tomography

    International Nuclear Information System (INIS)

    Kim, Bong Seok; Khambampati, Anil Kumar; Kim, Sin; Kim, Kyung Youn

    2011-01-01

    In electrical resistance tomography, electrical currents are injected through the electrodes placed on the surface of a domain and the corresponding voltages are measured. Based on these currents and voltage data, the cross-sectional resistivity distribution is reconstructed. Electrical resistance tomography shows high temporal resolution for monitoring fast transient processes, but it still remains a challenging problem to improve the spatial resolution of the reconstructed images. In this paper, a novel image reconstruction technique is proposed to improve the spatial resolution by employing an adaptive threshold method to the iterative Gauss–Newton method. Numerical simulations and phantom experiments have been performed to illustrate the superior performance of the proposed scheme in the sense of spatial resolution

  12. Development of CDMS-II Surface Event Rejection Techniques and Their Extensions to Lower Energy Thresholds

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, Thomas James [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-12-01

    The CDMS-II phase of the Cryogenic Dark Matter Search, a dark matter direct-detection experiment, was operated at the Soudan Underground Laboratory from 2003 to 2008. The full payload consisted of 30 ZIP detectors, totaling approximately 1.1 kg of Si and 4.8 kg of Ge, operated at temperatures of 50 mK. The ZIP detectors read out both ionization and phonon pulses from scatters within the crystals; channel segmentation and analysis of pulse timing parameters allowed e ective ducialization of the crystal volumes and background rejection su cient to set world-leading limits at the times of their publications. A full re-analysis of the CDMS-II data was motivated by an improvement in the event reconstruction algorithms which improved the resolution of ionization energy and timing information. The Ge data were re-analyzed using three distinct background-rejection techniques; the Si data from runs 125 - 128 were analyzed for the rst time using the most successful of the techniques from the Ge re-analysis. The results of these analyses prompted a novel \\mid-threshold" analysis, wherein energy thresholds were lowered but background rejection using phonon timing information was still maintained. This technique proved to have signi cant discrimination power, maintaining adequate signal acceptance and minimizing background leakage. The primary background for CDMS-II analyses comes from surface events, whose poor ionization collection make them di cult to distinguish from true nuclear recoil events. The novel detector technology of SuperCDMS, the successor to CDMS-II, uses interleaved electrodes to achieve full ionization collection for events occurring at the top and bottom detector surfaces. This, along with dual-sided ionization and phonon instrumentation, allows for excellent ducialization and relegates the surface-event rejection techniques of CDMS-II to a secondary level of background discrimination. Current and future SuperCDMS results hold great promise for mid- to low

  13. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    Science.gov (United States)

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  14. Mouse epileptic seizure detection with multiple EEG features and simple thresholding technique

    Science.gov (United States)

    Tieng, Quang M.; Anbazhagan, Ashwin; Chen, Min; Reutens, David C.

    2017-12-01

    Objective. Epilepsy is a common neurological disorder characterized by recurrent, unprovoked seizures. The search for new treatments for seizures and epilepsy relies upon studies in animal models of epilepsy. To capture data on seizures, many applications require prolonged electroencephalography (EEG) with recordings that generate voluminous data. The desire for efficient evaluation of these recordings motivates the development of automated seizure detection algorithms. Approach. A new seizure detection method is proposed, based on multiple features and a simple thresholding technique. The features are derived from chaos theory, information theory and the power spectrum of EEG recordings and optimally exploit both linear and nonlinear characteristics of EEG data. Main result. The proposed method was tested with real EEG data from an experimental mouse model of epilepsy and distinguished seizures from other patterns with high sensitivity and specificity. Significance. The proposed approach introduces two new features: negative logarithm of adaptive correlation integral and power spectral coherence ratio. The combination of these new features with two previously described features, entropy and phase coherence, improved seizure detection accuracy significantly. Negative logarithm of adaptive correlation integral can also be used to compute the duration of automatically detected seizures.

  15. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  16. Measurement of cross sections of threshold detectors with spectrum average technique

    International Nuclear Information System (INIS)

    Agus, Y.; Celenk, I.; Oezmen, A.

    2004-01-01

    Cross sections of the reactions 103 Rh(n, n') 103m Rh, 115 In(n, n') 115m In, 232 Th(n, f), 47 Ti(n, p) 47 Sc, 64 Zn(n, p) 64 Cu, 58 Ni(n, p) 58 Co, 54 Fe(n, p) 54 Mn, 46 Ti(n, p) 46 Sc, 27 Al(n, p) 27 Mg, 56 Fe(n, p) 56 Mn, 24 Mg(n, p) 24 Na, 59 Co(n, α) 56 Mn, 27 Al(n, α) 24 Na and 48 Ti(n, p) 48 Sc were measured with average neutron energies above effective threshold by using the activation method through usage of spectrum average technique in an irradiation system where there are three equivalent Am/Be sources, each of which has 592 GBq activity. The cross sections were determined with reference to the fast neutron fission cross section of 238 U. The measured values and published values are generally in agreement. (orig.)

  17. Absolute advantage

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2008-01-01

    textabstractA country is said to have an absolute advantage over another country in the production of a good or service if it can produce that good or service using fewer real resources. Equivalently, using the same inputs, the country can produce more output. The concept of absolute advantage can

  18. New multispectral MRI data fusion technique for white matter lesion segmentation: method and comparison with thresholding in FLAIR images

    International Nuclear Information System (INIS)

    Del C Valdes Hernandez, Maria; Ferguson, Karen J.; Chappell, Francesca M.; Wardlaw, Joanna M.

    2010-01-01

    Brain tissue segmentation by conventional threshold-based techniques may have limited accuracy and repeatability in older subjects. We present a new multispectral magnetic resonance (MR) image analysis approach for segmenting normal and abnormal brain tissue, including white matter lesions (WMLs). We modulated two 1.5T MR sequences in the red/green colour space and calculated the tissue volumes using minimum variance quantisation. We tested it on 14 subjects, mean age 73.3 ± 10 years, representing the full range of WMLs and atrophy. We compared the results of WML segmentation with those using FLAIR-derived thresholds, examined the effect of sampling location, WML amount and field inhomogeneities, and tested observer reliability and accuracy. FLAIR-derived thresholds were significantly affected by the location used to derive the threshold (P = 0.0004) and by WML volume (P = 0.0003), and had higher intra-rater variability than the multispectral technique (mean difference ± SD: 759 ± 733 versus 69 ± 326 voxels respectively). The multispectral technique misclassified 16 times fewer WMLs. Initial testing suggests that the multispectral technique is highly reproducible and accurate with the potential to be applied to routinely collected clinical MRI data. (orig.)

  19. Comparison of edge detection techniques for M7 subtype Leukemic cell in terms of noise filters and threshold value

    Directory of Open Access Journals (Sweden)

    Abdul Salam Afifah Salmi

    2017-01-01

    Full Text Available This paper will focus on the study and identifying various threshold values for two commonly used edge detection techniques, which are Sobel and Canny Edge detection. The idea is to determine which values are apt in giving accurate results in identifying a particular leukemic cell. In addition, evaluating suitability of edge detectors are also essential as feature extraction of the cell depends greatly on image segmentation (edge detection. Firstly, an image of M7 subtype of Acute Myelocytic Leukemia (AML is chosen due to its diagnosing which were found lacking. Next, for an enhancement in image quality, noise filters are applied. Hence, by comparing images with no filter, median and average filter, useful information can be acquired. Each threshold value is fixed with value 0, 0.25 and 0.5. From the investigation found, without any filter, Canny with a threshold value of 0.5 yields the best result.

  20. Multi-time-over-threshold technique for photomultiplier signal processing: Description and characterization of the SCOTT ASIC

    International Nuclear Information System (INIS)

    Ferry, S.; Guilloux, F.; Anvar, S.; Chateau, F.; Delagnes, E.; Gautard, V.; Louis, F.; Monmarthe, E.; Le Provost, H.; Russo, S.; Schuller, J.-P.; Stolarczyk, Th.; Vallage, B.; Zonca, E.

    2012-01-01

    KM3NeT aims to build a cubic-kilometer scale neutrino telescope in the Mediterranean Sea based on a 3D array of photomultiplier tubes. A dedicated ASIC, named SCOTT, has been developed for the readout electronics of the PMTs: it uses up to 16 adjustable thresholds to digitize the signals with the multi-time-over-threshold technique. Digital outputs of discriminators feed a circular sampling memory and a “first in first out” digital memory for derandomization. At the end of the data processing, the ASIC produces a digital waveform sampled at 800 MHz. A specific study was carried out to process PMT data and has showed that five specifically chosen thresholds are suited to reach the required timing precision. A dedicated method based on the duration of the signal over a given threshold allows an equivalent timing precision at any charge. A charge estimator using the information from the thresholds allows a charge determination within less than 20% up to 60 pe.

  1. Multi-time-over-threshold technique for photomultiplier signal processing: Description and characterization of the SCOTT ASIC

    Science.gov (United States)

    Ferry, S.; Guilloux, F.; Anvar, S.; Chateau, F.; Delagnes, E.; Gautard, V.; Louis, F.; Monmarthe, E.; Le Provost, H.; Russo, S.; Schuller, J.-P.; Stolarczyk, Th.; Vallage, B.; Zonca, E.; Representing the KM3NeT Consortium

    2012-12-01

    KM3NeT aims to build a cubic-kilometer scale neutrino telescope in the Mediterranean Sea based on a 3D array of photomultiplier tubes. A dedicated ASIC, named SCOTT, has been developed for the readout electronics of the PMTs: it uses up to 16 adjustable thresholds to digitize the signals with the multi-time-over-threshold technique. Digital outputs of discriminators feed a circular sampling memory and a “first in first out” digital memory for derandomization. At the end of the data processing, the ASIC produces a digital waveform sampled at 800 MHz. A specific study was carried out to process PMT data and has showed that five specifically chosen thresholds are suited to reach the required timing precision. A dedicated method based on the duration of the signal over a given threshold allows an equivalent timing precision at any charge. A charge estimator using the information from the thresholds allows a charge determination within less than 20% up to 60 pe.

  2. Thresholding: A Pixel-Level Image Processing Methodology Preprocessing Technique for an OCR System for the Brahmi Script

    Directory of Open Access Journals (Sweden)

    H. K. Anasuya Devi

    2006-12-01

    Full Text Available In this paper we study the methodology employed for preprocessing the archaeological images. We present the various algorithms used in the low-level processing stage of image analysis for Optical Character Recognition System for Brahmi Script. The image preprocessing technique covered in this paper is thresholding. We also try to analyze the results obtained by the pixel-level processing algorithms.

  3. Transformation from student to occupational therapist: Using the Delphi technique to identify the threshold concepts of occupational therapy.

    Science.gov (United States)

    Nicola-Richmond, Kelli M; Pépin, Geneviève; Larkin, Helen

    2016-04-01

    Understanding and facilitating the transformation from occupational therapy student to practitioner is central to the development of competent and work-ready graduates. However, the pivotal concepts and capabilities that need to be taught and learnt in occupational therapy are not necessarily explicit. The threshold concepts theory of teaching and learning proposes that every discipline has a set of transformational concepts that students must acquire in order to progress. As students acquire the threshold concepts, they develop a transformed way of understanding content related to their course of study which contributes to their developing expertise. The aim of this study was to identify the threshold concepts of occupational therapy. The Delphi technique, a data collection method that aims to demonstrate consensus in relation to important questions, was used with three groups comprising final year occupational therapy students (n = 11), occupational therapy clinicians (n = 21) and academics teaching occupational therapy (n = 10) in Victoria, Australia. Participants reached consensus regarding 10 threshold concepts for the occupational therapy discipline. These are: understanding and applying the models and theories of occupational therapy; occupation; evidence-based practice; clinical reasoning; discipline specific skills and knowledge; practising in context; a client-centred approach; the occupational therapist role; reflective practice and; a holistic approach. The threshold concepts identified provide valuable information for the discipline. They can potentially inform the development of competencies for occupational therapy and provide guidance for teaching and learning activities to facilitate the transformation to competent practitioner. © 2015 Occupational Therapy Australia.

  4. A study of time over threshold (TOT) technique for plastic scintillator counter

    International Nuclear Information System (INIS)

    Wu Jinjie; Chinese Academy of Sciences, Beijing; Heng Yuekun; Sun Zhijia; Wu Chong; Yang Guian; Jiang Chun Hua; Zhao Yuda

    2008-01-01

    A new charge measurement method, time over threshold (TOT), has been used in some gas detectors lately. Here TOT is studied for TOF system, made of plastic scintillator counter, which can simplify the electronics of the system. The signal characteristics are measured and analyzed with a high quality oscilloscope, including noise, pedestal, signal amplitude, total charge, rise time and the correlation between them. The TOT and charge are related and can be fitted by some empirical formula. The charge measurement resolution by TOT is given and this will help the design of TOF electronics. (authors)

  5. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  6. Assessment of Heart Rate Variability Thresholds from Incremental Treadmill Tests in Five Cross-Country Skiing Techniques.

    Directory of Open Access Journals (Sweden)

    Ibai Mendia-Iztueta

    Full Text Available The assessment of heart rate variability (HRV thresholds (HRVTs as an alternative of Ventilatory thresholds (VTs is a relatively new approach with increasing popularity which has not been conducted in cross-country (XC skiing yet. The main purpose of the present study was to assess HRVTs in the five main XC skiing-related techniques, double poling (DP, diagonal striding (DS, Nordic walking (NW, V1 skating (V1, and V2 skating (V2.Ten competitive skiers completed these incremental treadmill tests until exhaustion with a minimum of one to two recovery days in between each test. Ventilatory gases, HRV and poling frequencies were measured. The first HRV threshold (HRVT1 was assessed using two time-domain analysis methods, and the second HRV threshold (HRVT2 was assessed using two non-time varying frequency-domain analysis methods. HRVT1 was assessed by plotting the mean successive difference (MSD and standard deviation (SD of normalized R-R intervals to workload. HRVT1 was assessed by plotting high frequency power (HFP and the HFP relative to respiratory sinus arrhythmia (HFPRSA with workload. HRVTs were named after their methods (HRVT1-SD; HRVT1-MSD; HRVT2-HFP; HRVT2-HFP-RSA. The results showed that the only cases where the proposed HRVTs were good assessors of VTs were the HRVT1-SD of the DS test, the HRVT1-MSD of the DS and V2 tests, and the HRVT2-HFP-RSA of the NW test. The lack of a wider success of the assessment of HRVTs was reasoned to be mostly due to the high entrainment between the breathing and poling frequencies. As secondary finding, a novel Cardiolocomotor coupling mode was observed in the NW test. This new Cardiolocoomtor coupling mode corresponded to the whole bilateral poling cycle instead of corresponding to each poling action as it was reported to the date by the existing literature.

  7. Groundwater-dependent ecosystems: recent insights, new techniques and an ecosystem-scale threshold response

    Science.gov (United States)

    Eamus, D.; Zolfaghar, S.; Villalobos-Vega, R.; Cleverly, J.; Huete, A.

    2015-05-01

    extraction and discuss the use of C isotope ratios in xylem to reveal past influences of GW extraction. We conclude with a discussion of a depth-to-groundwater threshold in mesic and semi-arid GDEs. Across this threshold, significant changes occur in ecosystem structure and function.

  8. Power optimized variation aware dual-threshold SRAM cell design technique

    Directory of Open Access Journals (Sweden)

    Aminul Islam

    2011-02-01

    Full Text Available Aminul Islam1, Mohd Hasan21Department of Electronics and Communication Engineering, Birla Institute of Technology, Mesra, Ranchi, Jharkhand, India; 2Department of Electronics Engineering, Aligarh Muslim University, Aligarh, Uttar Pradesh, IndiaAbstract: Bulk complementary metal-oxide semiconductor (CMOS technology is facing enormous challenges at channel lengths below 45 nm, such as gate tunneling, device mismatch, random dopant fluctuations, and mobility degradation. Although multiple gate transistors and strained silicon devices overcome some of the bulk CMOS problems, it is sensible to look for revolutionary new materials and devices to replace silicon. It is obvious that future technology materials should exhibit higher mobility, better channel electrostatics, scalability, and robustness against process variations. Carbon nanotube-based technology is very promising because it has most of these desired features. There is a need to explore the potential of this emerging technology by designing circuits based on this technology and comparing their performance with that of existing bulk CMOS technology. In this paper, we propose a low-power variation-immune dual-threshold voltage carbon nanotube field effect transistor (CNFET-based seven-transistor (7T static random access memory (SRAM cell. The proposed CNFET-based 7T SRAM cell offers ~1.2× improvement in standby power, ~1.3× improvement in read delay, and ~1.1× improvement in write delay. It offers narrower spread in write access time (1.4× at optimum energy point [OEP] and 1.2× at 1 V. It features 56.3% improvement in static noise margin and 40% improvement in read static noise margin. All the simulation measurements are taken at proposed OEP decided by the optimum results obtained after extensive simulation on HSPICE (high-performance simulation program with integrated circuit emphasis environment.Keywords: carbon nanotube field effect transistor (CNFET, chirality vector, random dopant

  9. Using a Novel Absolute Ontogenetic Age Determination Technique to Calculate the Timing of Tooth Eruption in the Saber-Toothed Cat, Smilodon fatalis.

    Directory of Open Access Journals (Sweden)

    M Aleksander Wysocki

    Full Text Available Despite the superb fossil record of the saber-toothed cat, Smilodon fatalis, ontogenetic age determination for this and other ancient species remains a challenge. The present study utilizes a new technique, a combination of data from stable oxygen isotope analyses and micro-computed tomography, to establish the eruption rate for the permanent upper canines in Smilodon fatalis. The results imply an eruption rate of 6.0 millimeters per month, which is similar to a previously published average enamel growth rate of the S. fatalis upper canines (5.8 millimeters per month. Utilizing the upper canine growth rate, the upper canine eruption rate, and a previously published tooth replacement sequence, this study calculates absolute ontogenetic age ranges of tooth development and eruption in S. fatalis. The timing of tooth eruption is compared between S. fatalis and several extant conical-toothed felids, such as the African lion (Panthera leo. Results suggest that the permanent dentition of S. fatalis, except for the upper canines, was fully erupted by 14 to 22 months, and that the upper canines finished erupting at about 34 to 41 months. Based on these developmental age calculations, S. fatalis individuals less than 4 to 7 months of age were not typically preserved at Rancho La Brea. On the whole, S. fatalis appears to have had delayed dental development compared to dental development in similar-sized extant felids. This technique for absolute ontogenetic age determination can be replicated in other ancient species, including non-saber-toothed taxa, as long as the timing of growth initiation and growth rate can be determined for a specific feature, such as a tooth, and that growth period overlaps with the development of the other features under investigation.

  10. Using a Novel Absolute Ontogenetic Age Determination Technique to Calculate the Timing of Tooth Eruption in the Saber-Toothed Cat, Smilodon fatalis.

    Science.gov (United States)

    Wysocki, M Aleksander; Feranec, Robert S; Tseng, Zhijie Jack; Bjornsson, Christopher S

    2015-01-01

    Despite the superb fossil record of the saber-toothed cat, Smilodon fatalis, ontogenetic age determination for this and other ancient species remains a challenge. The present study utilizes a new technique, a combination of data from stable oxygen isotope analyses and micro-computed tomography, to establish the eruption rate for the permanent upper canines in Smilodon fatalis. The results imply an eruption rate of 6.0 millimeters per month, which is similar to a previously published average enamel growth rate of the S. fatalis upper canines (5.8 millimeters per month). Utilizing the upper canine growth rate, the upper canine eruption rate, and a previously published tooth replacement sequence, this study calculates absolute ontogenetic age ranges of tooth development and eruption in S. fatalis. The timing of tooth eruption is compared between S. fatalis and several extant conical-toothed felids, such as the African lion (Panthera leo). Results suggest that the permanent dentition of S. fatalis, except for the upper canines, was fully erupted by 14 to 22 months, and that the upper canines finished erupting at about 34 to 41 months. Based on these developmental age calculations, S. fatalis individuals less than 4 to 7 months of age were not typically preserved at Rancho La Brea. On the whole, S. fatalis appears to have had delayed dental development compared to dental development in similar-sized extant felids. This technique for absolute ontogenetic age determination can be replicated in other ancient species, including non-saber-toothed taxa, as long as the timing of growth initiation and growth rate can be determined for a specific feature, such as a tooth, and that growth period overlaps with the development of the other features under investigation.

  11. Results of a protocol of transfusion threshold and surgical technique on transfusion requirements in burn patients.

    Science.gov (United States)

    O'Mara, Michael S; Hayetian, Fernando; Slater, Harvey; Goldfarb, I William; Tolchin, Eric; Caushaj, Philip F

    2005-08-01

    Blood loss and high rates of transfusion in burn centers remains an area of ongoing concern. Blood use brings the risk of infection, adverse reaction, and immunosuppression. A protocol to reduce blood loss and blood use was implemented. Analysis included 3-year periods before and after institution of the protocol. All patients were transfused for a hemoglobin below 8.0 gm/dL. Operations per admission did not change during the two time periods (0.78 in each). Overall units transfused per operation decreased from 1.56+/-0.06 to 1.25+/-0.14 units after instituting the protocol (pburns of less than 20% surface area, declining from 386 to 46 units after protocol institution, from 0.37 to 0.04 units per admission, and from 0.79 to 0.08 units per operation in this group of smallest burns. There was no change noted in the larger burns. This study suggests that a defined protocol of hemostasis, technique, and transfusion trigger should be implemented in the process of burn excision and grafting. This will help especially those patients with the smallest burns, essentially eliminating transfusion need in that group.

  12. Theoretical detection threshold of the proton-acoustic range verification technique

    International Nuclear Information System (INIS)

    Ahmad, Moiz; Yousefi, Siavash; Xing, Lei; Xiang, Liangzhong

    2015-01-01

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10 6 per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range

  13. Theoretical detection threshold of the proton-acoustic range verification technique

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Moiz; Yousefi, Siavash; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States); Xiang, Liangzhong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019-1101 (United States)

    2015-10-15

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton

  14. Automatic Threshold Detector Techniques

    Science.gov (United States)

    1976-07-15

    Averaging CFAR in Non- Stationary Weibull Clutter, " L. Novak, (1974 IEEE Symposium on Information Theory ). 8. "The Weibull Distribution Applied to the... UGTS (K) ,Kml NPTS) 140 DO 153 K~lvNPT9 IF(SIGCSO(K) .LT.0. )SIOCSO(K).1 .E-50 IF(SIOWSO(K) .LT.0. )SIGWSQ(K)-1 .E-50 IF(SIONSG(K) .LT.O. )SIG3NSQCIO-1.E

  15. Do Anesthetic Techniques Influence the Threshold for Glomerular Capillary Hemorrhage Induced in Rats by Contrast-Enhanced Diagnostic Ultrasound?

    Science.gov (United States)

    Miller, Douglas L; Lu, Xiaofang; Fabiilli, Mario; Dou, Chunyan

    2016-02-01

    Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P Ultrasound in Medicine.

  16. Optical techniques for perfusion monitoring of the gastric tube after esophagectomy: a review of technologies and thresholds.

    Science.gov (United States)

    Jansen, S M; de Bruin, D M; van Berge Henegouwen, M I; Strackee, S D; Veelo, D P; van Leeuwen, T G; Gisbertz, S S

    2018-04-26

    arbitrary and not absolute values, and low flow or length of demarcation to the anastomosis (FI) both seem predictive values for necrosis intraoperatively. SDF and OCT are able to measure microvascular flow, intraoperative prediction of necrosis is not yet described.Optical techniques aim to improve perfusion monitoring by real-time, high-resolution, and high-contrast measurements and could therefore be valuable in intraoperative perfusion mapping. LDF and LSCI use perfusion units, and are therefore subjective in interpretation. FI visualizes influx directly, but needs a quantitative parameter for interpretation during surgery.

  17. Verification of threshold activation detection (TAD) technique in prompt fission neutron detection using scintillators containing 19F

    Science.gov (United States)

    Sibczynski, P.; Kownacki, J.; Moszyński, M.; Iwanowska-Hanke, J.; Syntfeld-Każuch, A.; Gójska, A.; Gierlik, M.; Kaźmierczak, Ł.; Jakubowska, E.; Kędzierski, G.; Kujawiński, Ł.; Wojnarowicz, J.; Carrel, F.; Ledieu, M.; Lainé, F.

    2015-09-01

    In the present study ⌀ 5''× 3'' and ⌀ 2''× 2'' EJ-313 liquid fluorocarbon as well as ⌀ 2'' × 3'' BaF2 scintillators were exposed to neutrons from a 252Cf neutron source and a Sodern Genie 16GT deuterium-tritium (D+T) neutron generator. The scintillators responses to β- particles with maximum endpoint energy of 10.4 MeV from the n+19F reactions were studied. Response of a ⌀ 5'' × 3'' BC-408 plastic scintillator was also studied as a reference. The β- particles are the products of interaction of fast neutrons with 19F which is a component of the EJ-313 and BaF2 scintillators. The method of fast neutron detection via fluorine activation is already known as Threshold Activation Detection (TAD) and was proposed for photofission prompt neutron detection from fissionable and Special Nuclear Materials (SNM) in the field of Homeland Security and Border Monitoring. Measurements of the number of counts between 6.0 and 10.5 MeV with a 252Cf source showed that the relative neutron detection efficiency ratio, defined as epsilonBaF2 / epsilonEJ-313-5'', is 32.0% ± 2.3% and 44.6% ± 3.4% for front-on and side-on orientation of the BaF2, respectively. Moreover, the ⌀ 5'' EJ-313 and side-on oriented BaF2 were also exposed to neutrons from the D+T neutron generator, and the relative efficiency epsilonBaF2 / epsilonEJ-313-5'' was estimated to be 39.3%. Measurements of prompt photofission neutrons with the BaF2 detector by means of data acquisition after irradiation (out-of-beam) of nuclear material and between the beam pulses (beam-off) techniques were also conducted on the 9 MeV LINAC of the SAPHIR facility.

  18. An Analysis Of The Benefits And Application Of Earned Value Management (EVM) Project Management Techniques For Dod Programs That Do Not Meet Dod Policy Thresholds

    Science.gov (United States)

    2017-12-01

    VALUE MANAGEMENT (EVM) PROJECT MANAGEMENT TECHNIQUES FOR DOD PROGRAMS THAT DO NOT MEET DOD POLICY THRESHOLDS December 2017 By: Randy Schneider...Joint applied project 4. TITLE AND SUBTITLE AN ANALYSIS OF THE BENEFITS AND APPLICATION OF EARNED VALUE MANAGEMENT (EVM) PROJECT MANAGEMENT ...performance reporting. The immediate objective of this research project was to examine the question: Can the application of EVM-Lite project management

  19. PET quantification with a histogram derived total activity metric: Superior quantitative consistency compared to total lesion glycolysis with absolute or relative SUV thresholds in phantoms and lung cancer patients

    International Nuclear Information System (INIS)

    Burger, Irene A.; Vargas, Hebert Alberto; Apte, Aditya; Beattie, Bradley J.; Humm, John L.; Gonen, Mithat; Larson, Steven M.; Ross Schmidtlein, C.

    2014-01-01

    Introduction: The increasing use of molecular imaging probes as biomarkers in oncology emphasizes the need for robust and stable methods for quantifying tracer uptake in PET imaging. The primary motivation for this research was to find an accurate method to quantify the total tumor uptake. Therefore we developed a histogram-based method to calculate the background subtracted lesion (BSL) activity and validated BSL by comparing the quantitative consistency with the total lesion glycolysis (TLG) in phantom and patient studies. Methods: A thorax phantom and a PET-ACR quality assurance phantom were scanned with increasing FDG concentrations. Volumes of interest (VOIs) were placed over each chamber. TLG was calculated with a fixed threshold at SUV 2.5 (TLG 2.5 ) and a relative threshold at 42% of SUV max (TLG 42% ). The histogram for each VOI was built and BSL was calculated. Comparison with the total injected FDG activity (TIA) was performed using concordance correlation coefficients (CCC) and the slope (a). Fifty consecutive patients with FDG-avid lung tumors were selected under an IRB waiver. TLG 42% , TLG 2.5 and BSL were compared to the reference standard calculating CCC and the slope. Results: In both phantoms, the CCC for lesions with a TIA ≤ 50 ml*SUV between TIA and BSL was higher and the slope closer to 1 (CCC = 0.933, a = 1.189), than for TLG 42% (CCC = 0.350, a = 0.731) or TLG 2.5 (CCC = 0.761, a = 0.727). In 50 lung lesions BSL had a slope closer to 1 compared to the reference activity than TLG 42% (a = 1.084 vs 0.618 – for high activity lesions) and also closer to 1 than TLG 2.5 (a = 1.117 vs 0.548 – for low activity lesions). Conclusion: The histogram based BSL correlated better with TIA in both phantom studies than TLG 2.5 or TLG 42% . Also in lung tumors, the BSL activity is overall more accurate in quantifying the lesion activity compared to the two most commonly applied TLG quantification methods

  20. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  1. Danish Towns during Absolutism

    DEFF Research Database (Denmark)

    This anthology, No. 4 in the Danish Urban Studies Series, presents in English recent significant research on Denmark's urban development during the Age of Absolutism, 1660-1848, and features 13 articles written by leading Danish urban historians. The years of Absolutism were marked by a general...

  2. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  3. Standard Test Method for Measurement of Hydrogen Embrittlement Threshold in Steel by the Incremental Step Loading Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method establishes a procedure to measure the susceptibility of steel to a time-delayed failure such as that caused by hydrogen. It does so by measuring the threshold for the onset of subcritical crack growth using standard fracture mechanics specimens, irregular-shaped specimens such as notched round bars, or actual product such as fasteners (2) (threaded or unthreaded) springs or components as identified in SAE J78, J81, and J1237. 1.2 This test method is used to evaluate quantitatively: 1.2.1 The relative susceptibility of steels of different composition or a steel with different heat treatments; 1.2.2 The effect of residual hydrogen in the steel as a result of processing, such as melting, thermal mechanical working, surface treatments, coatings, and electroplating; 1.2.3 The effect of hydrogen introduced into the steel caused by external environmental sources of hydrogen, such as fluids and cleaners maintenance chemicals, petrochemical products, and galvanic coupling in an aqueous enviro...

  4. Moral absolutism and ectopic pregnancy.

    Science.gov (United States)

    Kaczor, C

    2001-02-01

    If one accepts a version of absolutism that excludes the intentional killing of any innocent human person from conception to natural death, ectopic pregnancy poses vexing difficulties. Given that the embryonic life almost certainly will die anyway, how can one retain one's moral principle and yet adequately respond to a situation that gravely threatens the life of the mother and her future fertility? The four options of treatment most often discussed in the literature are non-intervention, salpingectomy (removal of tube with embryo), salpingostomy (removal of embryo alone), and use of methotrexate (MXT). In this essay, I review these four options and introduce a fifth (the milking technique). In order to assess these options in terms of the absolutism mentioned, it will also be necessary to discuss various accounts of the intention/foresight distinction. I conclude that salpingectomy, salpingostomy, and the milking technique are compatible with absolutist presuppositions, but not the use of methotrexate.

  5. Threshold network of a financial market using the P-value of correlation coefficients

    Science.gov (United States)

    Ha, Gyeong-Gyun; Lee, Jae Woo; Nobi, Ashadun

    2015-06-01

    Threshold methods in financial networks are important tools for obtaining important information about the financial state of a market. Previously, absolute thresholds of correlation coefficients have been used; however, they have no relation to the length of time. We assign a threshold value depending on the size of the time window by using the P-value concept of statistics. We construct a threshold network (TN) at the same threshold value for two different time window sizes in the Korean Composite Stock Price Index (KOSPI). We measure network properties, such as the edge density, clustering coefficient, assortativity coefficient, and modularity. We determine that a significant difference exists between the network properties of the two time windows at the same threshold, especially during crises. This implies that the market information depends on the length of the time window when constructing the TN. We apply the same technique to Standard and Poor's 500 (S&P500) and observe similar results.

  6. Development of an absolute x-ray fluorescence technique and high accuracy analytical methods for the determination of metals in catalytic materials

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Parker, W.C.

    1982-09-01

    A technique to produce characteristic x-rays by direct beta excitation for x-ray fluorescence analysis is presented. This is carried out by the introduction of 100 uCi of Pm-147 or Ni-63 to a small sample, which is placed directly in the window of a modified Si(Li) semiconductor. Corrected intensities are only given at 300 seconds for synthetic standards oscillating within the range 22 3 was used, to which the radioisotope was directly added. Preliminary results of the determination of eleven different radionuclides by means of an elementary x-ray analysis by using a new analytical technique, are discussed. In this technique the radioisotope and the sample are directly mixed, then this source-sample in the detector window and is protected from contamination with a thin plastic film. Future and possible applications of this technique are presented

  7. Absolute absorbed dose measurements with an array of ionization chambers as part of a routine procedure of quality control for the VMAT technique

    International Nuclear Information System (INIS)

    Clemente Gutierrez, F.; Cabello Murillo, E.; Ramirez Ros, J. C.; Casa de Julian, M. A. de la

    2011-01-01

    Arcotheraphy techniques volumetric modulated (VMAT) treatments involve continuous variation of the gantry rotation speed, positions of the sheets and dose rate. Since all treatments are administered by continuous arcs, these techniques require quality control procedures to ensure quick and easy constancy of the calibration factor (total absorbed dose) for any gantry angle. We report here a simple method of quality control for the measurement of the calibration factor using an array of ionization chambers. The measurements were performed on a unit of 6 MV Elekta Synergy with VMAT, belonging to the Radiation Oncology service of the Defense Central Hospital Gomez Ulla.

  8. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  9. Approach To Absolute Zero

    Indian Academy of Sciences (India)

    more and more difficult to remove heat as one approaches absolute zero. This is the ... A new and active branch of engineering ... This temperature is called the critical temperature, Te' For sulfur dioxide the critical ..... adsorbent charcoal.

  10. Autoshaping as a psychophysical paradigm: Absolute visual sensitivity in the pigeon

    Science.gov (United States)

    Passe, Dennis H.

    1981-01-01

    A classical conditioning procedure (autoshaping) was used to determine absolute visual threshold in the pigeon. This method provides the basis for a standardized visual psychophysical paradigm. PMID:16812228

  11. Encasing the Absolutes

    Directory of Open Access Journals (Sweden)

    Uroš Martinčič

    2014-05-01

    Full Text Available The paper explores the issue of structure and case in English absolute constructions, whose subjects are deduced by several descriptive grammars as being in the nominative case due to its supposed neutrality in terms of register. This deduction is countered by systematic accounts presented within the framework of the Minimalist Program which relate the case of absolute constructions to specific grammatical factors. Each proposal is shown as an attempt of analysing absolute constructions as basic predication structures, either full clauses or small clauses. I argue in favour of the small clause approach due to its minimal reliance on transformations and unique stipulations. Furthermore, I propose that small clauses project a singular category, and show that the use of two cases in English absolute constructions can be accounted for if they are analysed as depictive phrases, possibly selected by prepositions. The case of the subject in absolutes is shown to be a result of syntactic and non-syntactic factors. I thus argue in accordance with Minimalist goals that syntactic case does not exist, attributing its role in absolutes to other mechanisms.

  12. A new methodology based on the two-region model and microscopic noise analysis techniques for absolute measurements of betaeff, Λ and betaeff/Λ of the IPEN-MB-01 reactor

    International Nuclear Information System (INIS)

    Kuramoto, Renato Yoichi Ribeiro

    2007-01-01

    A new method for absolute measurement of the effective delayed neutron fraction, beta eff based on microscopic noise experiments and the Two-Region Model was developed at the IPEN/MB-01 Research Reactor facility. In contrast with other techniques like the Modified Bennett Method, Nelson-Number Method and 252 Cf-Source Method, the main advantage of this new methodology is to obtain the effective delayed neutron parameters in a purely experimental way, eliminating all parameters that are difficult to measure or calculate. In this way, Rossi-a and Feynman-a experiments for validation of this method were performed at the IPEN/MB-01 facility, and adopting the present approach, beta eff was measured with a 0.67% uncertainty. In addition, the prompt neutron generation time, A, and other parameters were also obtained in an absolute experimental way. In general, the final results agree well with values from frequency analysis experiments. The theory-experiment comparison reveals that JENDL-3.3 shows deviation for beta eff lower than 1% which meets the desired accuracy for the theoretical determination of this parameter. This work supports the reduction of the 235 U thermal yield as proposed by Okajima and Sakurai. (author)

  13. Absolute photoionization cross sections of atomic oxygen

    Science.gov (United States)

    Samson, J. A. R.; Pareek, P. N.

    1985-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  14. A double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]-basimglurant and absolute bioavailability after oral administration and concomitant intravenous microdose administration of [13C6]-labeled basimglurant in humans.

    Science.gov (United States)

    Guerini, Elena; Schadt, Simone; Greig, Gerard; Haas, Ruth; Husser, Christophe; Zell, Manfred; Funk, Christoph; Hartung, Thomas; Gloge, Andreas; Mallalieu, Navita L

    2017-02-01

    1. The emerging technique of employing intravenous microdose administration of an isotope tracer concomitantly with an [ 14 C]-labeled oral dose was used to characterize the disposition and absolute bioavailability of a novel metabotropic glutamate 5 (mGlu5) receptor antagonist under clinical development for major depressive disorder (MDD). 2. Six healthy volunteers received a single 1 mg [ 12 C/ 14 C]-basimglurant (2.22 MBq) oral dose and a concomitant i.v. tracer dose of 100 μg of [ 13 C 6 ]-basimglurant. Concentrations of [ 12 C]-basimglurant and the stable isotope [ 13 C 6 ]-basimglurant were determined in plasma by a specific LC/MS-MS method. Total [ 14 C] radioactivity was determined in whole blood, plasma, urine and feces by liquid scintillation counting. Metabolic profiling was conducted in plasma, urine, blood cell pellet and feces samples. 3. The mean absolute bioavailability after oral administration (F) of basimglurant was ∼67% (range 45.7-77.7%). The major route of [ 14 C]-radioactivity excretion, primarily in form of metabolites, was in urine (mean recovery 73.4%), with the remainder excreted in feces (mean recovery 26.5%). The median t max for [ 12 C]-basimglurant after the oral administration was 0.71 h (range 0.58-1.00) and the mean terminal half-life was 77.2 ± 38.5 h. Terminal half-life for the [ 14 C]-basimglurant was 178 h indicating presence of metabolites with a longer terminal half-life. Five metabolites were identified with M1-Glucuronide as major and the others in trace amounts. There was minimal binding of drug to RBCs. IV pharmacokinetics was characterized with a mean ± SD CL of 11.8 ± 7.4 mL/h and a Vss of 677 ± 229 L. 4. The double-tracer technique used in this study allowed to simultaneously characterize the absolute bioavailability and disposition characteristics of the new oral molecular entity in a single study.

  15. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  16. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  17. Threshold behavior in electron-atom scattering

    International Nuclear Information System (INIS)

    Sadeghpour, H.R.; Greene, C.H.

    1996-01-01

    Ever since the classic work of Wannier in 1953, the process of treating two threshold electrons in the continuum of a positively charged ion has been an active field of study. The authors have developed a treatment motivated by the physics below the double ionization threshold. By modeling the double ionization as a series of Landau-Zener transitions, they obtain an analytical formulation of the absolute threshold probability which has a leading power law behavior, akin to Wannier's law. Some of the noteworthy aspects of this derivation are that the derivation can be conveniently continued below threshold giving rise to a open-quotes cuspclose quotes at threshold, and that on both sides of the threshold, absolute values of the cross sections are obtained

  18. Hoeren unter Wasser: Absolute Reizschwellen und Richtungswahrnehnumg (Underwater Hearing: Absolute Thresholds and Sound Localization),

    Science.gov (United States)

    The article deals first with the theoretical foundations of underwater hearing, and the effects of the acoustical characteristics of water on hearing...lead to the conclusion that, in water , man can locate the direction of sound at low and at very high tonal frequencies of the audio range, but this ability is probably vanishing in the middle range of frequencies. (Author)

  19. Effekten af absolut kumulation

    DEFF Research Database (Denmark)

    Kyvsgaard, Britta; Klement, Christian

    2012-01-01

    Som led i finansloven for 2011 blev regeringen og forligspartierne enige om at undersøge reglerne om strafudmåling ved samtidig pådømmelse af flere kriminelle forhold og i forbindelse hermed vurdere konsekvenserne af at ændre de gældende regler i forhold til kapacitetsbehovet i Kriminalforsorgens...... samlet bødesum ved en absolut kumulation i forhold til en modereret kumulation, som nu er gældende....

  20. A Fast Method for Measuring Psychophysical Thresholds Across the Cochlear Implant Array

    Directory of Open Access Journals (Sweden)

    Julie A. Bierer

    2015-02-01

    Full Text Available A rapid threshold measurement procedure, based on Bekesy tracking, is proposed and evaluated for use with cochlear implants (CIs. Fifteen postlingually deafened adult CI users participated. Absolute thresholds for 200-ms trains of biphasic pulses were measured using the new tracking procedure and were compared with thresholds obtained with a traditional forced-choice adaptive procedure under both monopolar and quadrupolar stimulation. Virtual spectral sweeps across the electrode array were implemented in the tracking procedure via current steering, which divides the current between two adjacent electrodes and varies the proportion of current directed to each electrode. Overall, no systematic differences were found between threshold estimates with the new channel sweep procedure and estimates using the adaptive forced-choice procedure. Test–retest reliability for the thresholds from the sweep procedure was somewhat poorer than for thresholds from the forced-choice procedure. However, the new method was about 4 times faster for the same number of repetitions. Overall the reliability and speed of the new tracking procedure provides it with the potential to estimate thresholds in a clinical setting. Rapid methods for estimating thresholds could be of particular clinical importance in combination with focused stimulation techniques that result in larger threshold variations between electrodes.

  1. Absolute measurement of 85Sr

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Watanabe, Tamaki

    1978-01-01

    An extension of 4πe.x-γ coincidence technique is described to measure the absolute disintegration rate of 85 Sr. This nuclide shows electron capture-gamma decay, and 514keV level of 85 Rb is a meta-stable state with half life of 0.958 μsec. Therefore, the conventional 4 πe.x-γ coincidence technique with about 1 μsec of resolution time can not be applied to this nuclide. To measure the absolute disintegration rate of this, the delayed 4 πe.x-γ coincidence technique with two different resolution time has been used. The disintegration rate was determined from four counting rates of electron-x ray, gamma ray and two coincidences, and the true disintegration rate could be obtained by extraporation of the electron-x ray detection efficiency to 1. Two resolution time appearing in the calculation formulas were determined from the chance coincidence between electron-x ray and delayed gamma ray signals. When the coincidence countings with three different resolution time were carried out by one coincidence circuit, the results calculated from all combinations did not agree each other. However, when the two coincidence circuits of the same type were used to fix the resolution time, a good coincidence absorption function was obtained and the disintegration rate was determined with accuracy of +- 0.5%. To evaluate the validity of the results the disintegration rates were measured by two NaI (Tl) scintillation detectors whose gamma-ray detection efficiency was previously determined and both results were agreed within accuracy of +- 0.5%. This method can be applied with nearly same accuracy for the beta-gamma decay nuclide possessing a meta-stable state of the half life below about 10 μsec. (auth.)

  2. Towards absolute neutrino masses

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory 106-38, Caltech, Pasadena, CA 91125 (United States)

    2007-06-15

    Various ways of determining the absolute neutrino masses are briefly reviewed and their sensitivities compared. The apparent tension between the announced but unconfirmed observation of the 0{nu}{beta}{beta} decay and the neutrino mass upper limit based on observational cosmology is used as an example of what could happen eventually. The possibility of a 'nonstandard' mechanism of the 0{nu}{beta}{beta} decay is stressed and the ways of deciding which of the possible mechanisms is actually operational are described. The importance of the 0{nu}{beta}{beta} nuclear matrix elements is discussed and their uncertainty estimated.

  3. Psychophysical evaluation of the image quality of a dynamic flat-panel digital x-ray image detector using the threshold contrast detail detectability (TCDD) technique

    Science.gov (United States)

    Davies, Andrew G.; Cowen, Arnold R.; Bruijns, Tom J. C.

    1999-05-01

    We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilizing a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 (mu) R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 (mu) R/s all three-systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent

  4. Absolute decay parametric instability of high-temperature plasma

    International Nuclear Information System (INIS)

    Zozulya, A.A.; Silin, V.P.; Tikhonchuk, V.T.

    1986-01-01

    A new absolute decay parametric instability having wide spatial localization region is shown to be possible near critical plasma density. Its excitation is conditioned by distributed feedback of counter-running Langmuir waves occurring during parametric decay of incident and reflected pumping wave components. In a hot plasma with the temperature of the order of kiloelectronvolt its threshold is lower than that of a known convective decay parametric instability. Minimum absolute instability threshold is shown to be realized under conditions of spatial parametric resonance of higher orders

  5. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  6. Near threshold fatigue testing

    Science.gov (United States)

    Freeman, D. C.; Strum, M. J.

    1993-01-01

    Measurement of the near-threshold fatigue crack growth rate (FCGR) behavior provides a basis for the design and evaluation of components subjected to high cycle fatigue. Typically, the near-threshold fatigue regime describes crack growth rates below approximately 10(exp -5) mm/cycle (4 x 10(exp -7) inch/cycle). One such evaluation was recently performed for the binary alloy U-6Nb. The procedures developed for this evaluation are described in detail to provide a general test method for near-threshold FCGR testing. In particular, techniques for high-resolution measurements of crack length performed in-situ through a direct current, potential drop (DCPD) apparatus, and a method which eliminates crack closure effects through the use of loading cycles with constant maximum stress intensity are described.

  7. Absolute Gravimetry in Fennoscandia

    DEFF Research Database (Denmark)

    Pettersen, B. R; TImmen, L.; Gitlein, O.

    The Fennoscandian postglacial uplift has been mapped geometrically using precise levelling, tide gauges, and networks of permanent GPS stations. The results identify major uplift rates at sites located around the northern part of the Gulf of Bothnia. The vertical motions decay in all directions...... motions) has its major axis in the direction of southwest to northeast and covers a distance of about 2000 km. Absolute gravimetry was made in Finland and Norway in 1976 with a rise-and fall instrument. A decade later the number of gravity stations was expanded by JILAg-5, in Finland from 1988, in Norway...... time series of several years are now available. Along the coast there are nearby tide gauge stations, many of which have time series of several decades. We describe the observing network, procedures, auxiliary observations, and discuss results obtained for selected sites. We compare the gravity results...

  8. Hydrometeorological threshold conditions for debris flow initiation in Norway

    Directory of Open Access Journals (Sweden)

    N. K. Meyer

    2012-10-01

    Full Text Available Debris flows, triggered by extreme precipitation events and rapid snow melt, cause considerable damage to the Norwegian infrastructure every year. To define intensity-duration (ID thresholds for debris flow initiation critical water supply conditions arising from intensive rainfall or snow melt were assessed on the basis of daily hydro-meteorological information for 502 documented debris flow events. Two threshold types were computed: one based on absolute ID relationships and one using ID relationships normalized by the local precipitation day normal (PDN. For each threshold type, minimum, medium and maximum threshold values were defined by fitting power law curves along the 10th, 50th and 90th percentiles of the data population. Depending on the duration of the event, the absolute threshold intensities needed for debris flow initiation vary between 15 and 107 mm day−1. Since the PDN changes locally, the normalized thresholds show spatial variations. Depending on location, duration and threshold level, the normalized threshold intensities vary between 6 and 250 mm day−1. The thresholds obtained were used for a frequency analysis of over-threshold events giving an estimation of the exceedance probability and thus potential for debris flow events in different parts of Norway. The absolute thresholds are most often exceeded along the west coast, while the normalized thresholds are most frequently exceeded on the west-facing slopes of the Norwegian mountain ranges. The minimum thresholds derived in this study are in the range of other thresholds obtained for regions with a climate comparable to Norway. Statistics reveal that the normalized threshold is more reliable than the absolute threshold as the former shows no spatial clustering of debris flows related to water supply events captured by the threshold.

  9. Measuring Input Thresholds on an Existing Board

    Science.gov (United States)

    Kuperman, Igor; Gutrich, Daniel G.; Berkun, Andrew C.

    2011-01-01

    A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and

  10. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  11. Local bleaching thresholds established by remote sensing techniques vary among reefs with deviating bleaching patterns during the 2012 event in the Arabian/Persian Gulf.

    Science.gov (United States)

    Shuail, Dawood; Wiedenmann, Jörg; D'Angelo, Cecilia; Baird, Andrew H; Pratchett, Morgan S; Riegl, Bernhard; Burt, John A; Petrov, Peter; Amos, Carl

    2016-04-30

    A severe bleaching event affected coral communities off the coast of Abu Dhabi, UAE in August/September, 2012. In Saadiyat and Ras Ghanada reefs ~40% of the corals showed signs of bleaching. In contrast, only 15% of the corals were affected on Delma reef. Bleaching threshold temperatures for these sites were established using remotely sensed sea surface temperature (SST) data recorded by MODIS-Aqua. The calculated threshold temperatures varied between locations (34.48 °C, 34.55 °C, 35.05 °C), resulting in site-specific deviations in the numbers of days during which these thresholds were exceeded. Hence, the less severe bleaching of Delma reef might be explained by the lower relative heat stress experienced by this coral community. However, the dominance of Porites spp. that is associated with the long-term exposure of Delma reef to elevated temperatures, as well as the more pristine setting may have additionally contributed to the higher coral bleaching threshold for this site. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. Absolute risk, absolute risk reduction and relative risk

    Directory of Open Access Journals (Sweden)

    Jose Andres Calvache

    2012-12-01

    Full Text Available This article illustrates the epidemiological concepts of absolute risk, absolute risk reduction and relative risk through a clinical example. In addition, it emphasizes the usefulness of these concepts in clinical practice, clinical research and health decision-making process.

  13. Projective absoluteness for Sacks forcing

    NARCIS (Netherlands)

    Ikegami, D.

    2009-01-01

    We show that Sigma(1)(3)-absoluteness for Sacks forcing is equivalent to the nonexistence of a Delta(1)(2) Bernstein set. We also show that Sacks forcing is the weakest forcing notion among all of the preorders that add a new real with respect to Sigma(1)(3) forcing absoluteness.

  14. Benzofuranoid and bicyclooctanoid neolignans:absolute configuration

    International Nuclear Information System (INIS)

    Alvarenga, M.A. de; Giesbrecht, A.M.; Gottlieb, O.R.; Yoshida, M.

    1977-01-01

    The naturally occuring benzofuranoid and bicyclo (3,2,1) octanoid neolignans have their relative configurations established by 1 H and 13 C NMR, inclusively with aid of the solvent shift technique. Interconversion of the benzofuranoid type compounds, as well as for a benzofuranoid to a bicyclooctanoid derivate, make ORD correlations, ultimately with (2S, 3S) - and (2R,3R)-2,3- dihydrobenzofurans, possible, and led to the absolute configurations of both series of neolignans [pt

  15. Cryogenic, Absolute, High Pressure Sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  16. Absolute flux scale for radioastronomy

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Stankevich, K.S.

    1986-01-01

    The authors propose and provide support for a new absolute flux scale for radio astronomy, which is not encumbered with the inadequacies of the previous scales. In constructing it the method of relative spectra was used (a powerful tool for choosing reference spectra). A review is given of previous flux scales. The authors compare the AIS scale with the scale they propose. Both scales are based on absolute measurements by the ''artificial moon'' method, and they are practically coincident in the range from 0.96 to 6 GHz. At frequencies above 6 GHz, 0.96 GHz, the AIS scale is overestimated because of incorrect extrapolation of the spectra of the primary and secondary standards. The major results which have emerged from this review of absolute scales in radio astronomy are summarized

  17. CARA Risk Assessment Thresholds

    Science.gov (United States)

    Hejduk, M. D.

    2016-01-01

    Warning remediation threshold (Red threshold): Pc level at which warnings are issued, and active remediation considered and usually executed. Analysis threshold (Green to Yellow threshold): Pc level at which analysis of event is indicated, including seeking additional information if warranted. Post-remediation threshold: Pc level to which remediation maneuvers are sized in order to achieve event remediation and obviate any need for immediate follow-up maneuvers. Maneuver screening threshold: Pc compliance level for routine maneuver screenings (more demanding than regular Red threshold due to additional maneuver uncertainty).

  18. An adaptive technique for multiscale approximate entropy (MAEbin) threshold (r) selection: application to heart rate variability (HRV) and systolic blood pressure variability (SBPV) under postural stress.

    Science.gov (United States)

    Singh, Amritpal; Saini, Barjinder Singh; Singh, Dilbag

    2016-06-01

    Multiscale approximate entropy (MAE) is used to quantify the complexity of a time series as a function of time scale τ. Approximate entropy (ApEn) tolerance threshold selection 'r' is based on either: (1) arbitrary selection in the recommended range (0.1-0.25) times standard deviation of time series (2) or finding maximum ApEn (ApEnmax) i.e., the point where self-matches start to prevail over other matches and choosing the corresponding 'r' (rmax) as threshold (3) or computing rchon by empirically finding the relation between rmax, SD1/SD2 ratio and N using curve fitting, where, SD1 and SD2 are short-term and long-term variability of a time series respectively. None of these methods is gold standard for selection of 'r'. In our previous study [1], an adaptive procedure for selection of 'r' is proposed for approximate entropy (ApEn). In this paper, this is extended to multiple time scales using MAEbin and multiscale cross-MAEbin (XMAEbin). We applied this to simulations i.e. 50 realizations (n = 50) of random number series, fractional Brownian motion (fBm) and MIX (P) [1] series of data length of N = 300 and short term recordings of HRV and SBPV performed under postural stress from supine to standing. MAEbin and XMAEbin analysis was performed on laboratory recorded data of 50 healthy young subjects experiencing postural stress from supine to upright. The study showed that (i) ApEnbin of HRV is more than SBPV in supine position but is lower than SBPV in upright position (ii) ApEnbin of HRV decreases from supine i.e. 1.7324 ± 0.112 (mean ± SD) to upright 1.4916 ± 0.108 due to vagal inhibition (iii) ApEnbin of SBPV increases from supine i.e. 1.5535 ± 0.098 to upright i.e. 1.6241 ± 0.101 due sympathetic activation (iv) individual and cross complexities of RRi and systolic blood pressure (SBP) series depend on time scale under consideration (v) XMAEbin calculated using ApEnmax is correlated with cross-MAE calculated using ApEn (0.1-0.26) in steps of 0

  19. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  20. Relativistic Absolutism in Moral Education.

    Science.gov (United States)

    Vogt, W. Paul

    1982-01-01

    Discusses Emile Durkheim's "Moral Education: A Study in the Theory and Application of the Sociology of Education," which holds that morally healthy societies may vary in culture and organization but must possess absolute rules of moral behavior. Compares this moral theory with current theory and practice of American educators. (MJL)

  1. Forcing absoluteness and regularity properties

    NARCIS (Netherlands)

    Ikegami, D.

    2010-01-01

    For a large natural class of forcing notions, we prove general equivalence theorems between forcing absoluteness statements, regularity properties, and transcendence properties over L and the core model K. We use our results to answer open questions from set theory of the reals.

  2. Some absolutely effective product methods

    Directory of Open Access Journals (Sweden)

    H. P. Dikshit

    1992-01-01

    Full Text Available It is proved that the product method A(C,1, where (C,1 is the Cesàro arithmetic mean matrix, is totally effective under certain conditions concerning the matrix A. This general result is applied to study absolute Nörlund summability of Fourier series and other related series.

  3. Threshold quantum cryptography

    International Nuclear Information System (INIS)

    Tokunaga, Yuuki; Okamoto, Tatsuaki; Imoto, Nobuyuki

    2005-01-01

    We present the concept of threshold collaborative unitary transformation or threshold quantum cryptography, which is a kind of quantum version of threshold cryptography. Threshold quantum cryptography states that classical shared secrets are distributed to several parties and a subset of them, whose number is greater than a threshold, collaborates to compute a quantum cryptographic function, while keeping each share secretly inside each party. The shared secrets are reusable if no cheating is detected. As a concrete example of this concept, we show a distributed protocol (with threshold) of conjugate coding

  4. Theory of threshold phenomena

    International Nuclear Information System (INIS)

    Hategan, Cornel

    2002-01-01

    Theory of Threshold Phenomena in Quantum Scattering is developed in terms of Reduced Scattering Matrix. Relationships of different types of threshold anomalies both to nuclear reaction mechanisms and to nuclear reaction models are established. Magnitude of threshold effect is related to spectroscopic factor of zero-energy neutron state. The Theory of Threshold Phenomena, based on Reduced Scattering Matrix, does establish relationships between different types of threshold effects and nuclear reaction mechanisms: the cusp and non-resonant potential scattering, s-wave threshold anomaly and compound nucleus resonant scattering, p-wave anomaly and quasi-resonant scattering. A threshold anomaly related to resonant or quasi resonant scattering is enhanced provided the neutron threshold state has large spectroscopic amplitude. The Theory contains, as limit cases, Cusp Theories and also results of different nuclear reactions models as Charge Exchange, Weak Coupling, Bohr and Hauser-Feshbach models. (author)

  5. Measurement of absolute concentrations of minor reactive species in flames by cavity ring down absorption spectroscopy (CRDS) method; Mesure de concentrations absolues d'especes reactives minoritaires dans les flammes par la technique d'absorption cavity ring down spectroscopy (CRDS)

    Energy Technology Data Exchange (ETDEWEB)

    Mercier, X.

    2000-11-15

    Combustion processes, which represent our main source of energy today, arouse still numerous questioning. It likes essentially the complexity of the involved chemical mechanisms as well as in the inherent difficulty to the study of an environment which is the field of several thousand simultaneous reactions. Now, even if powerful models exist, allowing the simulation of complex chemical systems, they can not predict any process of combustion and the experimental approach of these ones is still essential for the improvement of the existing models. In particular, the quantitative measure of minor species in flames constitutes a fundamental stage in the validation of the chemical mechanisms with high temperature. It is in this optics that we developed a new technique for flames study, the Cavity Ring-Down Spectroscopy (CRDS). This technique (appeared to the end of the 80's (O' Keefe and Deacon [1988]) within the framework of a spectroscopic study) is similar to a very high sensibility absorption method. The principle of the CRDS technique is based on the measure of the lifetime of an laser pulse injected in an optical cavity within which is an absorbing sample. in this report, we show the interest and the potentialities of the CRDS for the study of homogeneous flames. To do it, we clarify in detail the principle of the CRDS and the care to be taken for the measure of absolute concentrations. Besides, a comparison of the absolute concentrations profiles obtained by CRDS (of CN and CH notably) in a CH{sub 4} /O{sub 2} flame seeded with NO, with those stemming from the modelling by means of the software PREMIX is also presented. The very good agreement which reveals this comparison tends to show that the CRDS, because of its high sensibility and its direct quantitative character, is one of the most efficient methods for the measure of minor species absolute concentrations in homogeneous flames. (author)

  6. Absolute magnitudes by statistical parallaxes

    International Nuclear Information System (INIS)

    Heck, A.

    1978-01-01

    The author describes an algorithm for stellar luminosity calibrations (based on the principle of maximum likelihood) which allows the calibration of relations of the type: Msub(i)=sup(N)sub(j=1)Σqsub(j)Csub(ij), i=1,...,n, where n is the size of the sample at hand, Msub(i) are the individual absolute magnitudes, Csub(ij) are observational quantities (j=1,...,N), and qsub(j) are the coefficients to be determined. If one puts N=1 and Csub(iN)=1, one has q 1 =M(mean), the mean absolute magnitude of the sample. As additional output, the algorithm provides one also with the dispersion in magnitude of the sample sigmasub(M), the mean solar motion (U,V,W) and the corresponding velocity ellipsoid (sigmasub(u), sigmasub(v), sigmasub(w). The use of this algorithm is illustrated. (Auth.)

  7. Absolute gravity measurements in California

    Science.gov (United States)

    Zumberge, M. A.; Sasagawa, G.; Kappus, M.

    1986-08-01

    An absolute gravity meter that determines the local gravitational acceleration by timing a freely falling mass with a laser interferometer has been constructed. The instrument has made measurements at 11 sites in California, four in Nevada, and one in France. The uncertainty in the results is typically 10 microgal. Repeated measurements have been made at several of the sites; only one shows a substantial change in gravity.

  8. The Absolute Immanence in Deleuze

    OpenAIRE

    Park, Daeseung

    2013-01-01

    The absolute immanence in Deleuze Daeseung Park Abstract The plane of immanence is not unique. Deleuze and Guattari suppose a multiplicity of planes. Each great philosopher draws new planes on his own way, and these planes constitute the "time of philosophy". We can, therefore, "present the entire history of philosophy from the viewpoint of the institution of a plane of immanence" or present the time of philosophy from the viewpoint of the superposition and of the coexistence of planes. Howev...

  9. Photoionization cross section measurements of the excited states of cobalt in the near-threshold region

    Directory of Open Access Journals (Sweden)

    Xianfeng Zheng

    2014-10-01

    Full Text Available We present measurements of photoionization cross-sections of the excited states of cobalt using a two-color, two-step resonance ionization technique in conjunction with a molecular beam time of flight (TOF mass spectrometer. The atoms were produced by the laser vaporization of a cobalt rod, coupled with a supersonic gas jet. The absolute photoionization cross-sections at threshold and near-threshold regions (0-1.2 eV were measured, and the measured values ranged from 4.2±0.7 Mb to 10.5±1.8 Mb. The lifetimes of four odd parity energy levels are reported for the first time.

  10. Auditory processing in absolute pitch possessors

    Science.gov (United States)

    McKetton, Larissa; Schneider, Keith A.

    2018-05-01

    Absolute pitch (AP) is a rare ability in classifying a musical pitch without a reference standard. It has been of great interest to researchers studying auditory processing and music cognition since it is seldom expressed and sheds light on influences pertaining to neurodevelopmental biological predispositions and the onset of musical training. We investigated the smallest frequency that could be detected or just noticeable difference (JND) between two pitches. Here, we report significant differences in JND thresholds in AP musicians and non-AP musicians compared to non-musician control groups at both 1000 Hz and 987.76 Hz testing frequencies. Although the AP-musicians did better than non-AP musicians, the difference was not significant. In addition, we looked at neuro-anatomical correlates of musicianship and AP using structural MRI. We report increased cortical thickness of the left Heschl's Gyrus (HG) and decreased cortical thickness of the inferior frontal opercular gyrus (IFO) and circular insular sulcus volume (CIS) in AP compared to non-AP musicians and controls. These structures may therefore be optimally enhanced and reduced to form the most efficient network for AP to emerge.

  11. Secure information management using linguistic threshold approach

    CERN Document Server

    Ogiela, Marek R

    2013-01-01

    This book details linguistic threshold schemes for information sharing. It examines the opportunities of using these techniques to create new models of managing strategic information shared within a commercial organisation or a state institution.

  12. A Robust Threshold for Iterative Channel Estimation in OFDM Systems

    Directory of Open Access Journals (Sweden)

    A. Kalaycioglu

    2010-04-01

    Full Text Available A novel threshold computation method for pilot symbol assisted iterative channel estimation in OFDM systems is considered. As the bits are transmitted in packets, the proposed technique is based on calculating a particular threshold for each data packet in order to select the reliable decoder output symbols to improve the channel estimation performance. Iteratively, additional pilot symbols are established according to the threshold and the channel is re-estimated with the new pilots inserted to the known channel estimation pilot set. The proposed threshold calculation method for selecting additional pilots performs better than non-iterative channel estimation, no threshold and fixed threshold techniques in poor HF channel simulations.

  13. Absolute experimental cross sections for the electron impact ionization of rubidium. Technical summary report

    International Nuclear Information System (INIS)

    Hughes, D.W.; Feeney, R.K.

    1980-01-01

    The absolute cross sections for the double, triple, and quadruple ionization of Rb + ions by electron impact have been measured from below their respective thresholds to approximately 3000 eV. This determination has been accomplished using a crossed beam facility in which monoenergetic beams of ions and electrons are caused to intersect at right angles in a well-defined collision volume. Multiply charged, product ions born as a result of the electron impact are deflected into their respective detectors by cascaded electrostatic analyzers. The multiply charged beam current component is measured by means of a vibrating reed electrometer operating in the rate-of-charge mode. The required singly charged rubidium ions are produced in a thermionic ion source and pass through a series of focusing, collimating and deflecting structures before entering the interaction region. A thermionically generated, rectangular electron beam intercepts the target ions in a spatially designated collision volume. Just prior to entering this interaction region the two beams can be made to pass through a movable slit scanner which determines their spatial profiles. The various charged particle currents, energies and beam current density distributions represent the experimental data from which the desired absolute cross sections have been determined. The results obtained with this technique are compared with available theoretical predictions of the appropriate cross sections

  14. Android Apps for Absolute Beginners

    CERN Document Server

    Jackson, Wallace

    2011-01-01

    Anybody can start building simple apps for the Android platform, and this book will show you how! Android Apps for Absolute Beginners takes you through the process of getting your first Android applications up and running using plain English and practical examples. It cuts through the fog of jargon and mystery that surrounds Android application development, and gives you simple, step-by-step instructions to get you started.* Teaches Android application development in language anyone can understand, giving you the best possible start in Android development * Provides simple, step-by-step exampl

  15. Absolute pitch: a case study.

    Science.gov (United States)

    Vernon, P E

    1977-11-01

    The auditory skill known as 'absolute pitch' is discussed, and it is shown that this differs greatly in accuracy of identification or reproduction of musical tones from ordinary discrimination of 'tonal height' which is to some extent trainable. The present writer possessed absolute pitch for almost any tone or chord over the normal musical range, from about the age of 17 to 52. He then started to hear all music one semitone too high, and now at the age of 71 it is heard a full tone above the true pitch. Tests were carried out under controlled conditions, in which 68 to 95 per cent of notes were identified as one semitone or one tone higher than they should be. Changes with ageing seem more likely to occur in the elasticity of the basilar membrane mechanisms than in the long-term memory which is used for aural analysis of complex sounds. Thus this experience supports the view that some resolution of complex sounds takes place at the peripheral sense organ, and this provides information which can be incorrect, for interpretation by the cortical centres.

  16. Absolute measurement of 152Eu

    International Nuclear Information System (INIS)

    Baba, Hiroshi; Baba, Sumiko; Ichikawa, Shinichi; Sekine, Toshiaki; Ishikawa, Isamu

    1981-08-01

    A new method of the absolute measurement for 152 Eu was established based on the 4πβ-γ spectroscopic anti-coincidence method. It is a coincidence counting method consisting of a 4πβ-counter and a Ge(Li) γ-ray detector, in which the effective counting efficiencies of the 4πβ-counter for β-rays, conversion electrons, and Auger electrons were obtained by taking the intensity ratios for certain γ-rays between the single spectrum and the spectrum coincident with the pulses from the 4πβ-counter. First, in order to verify the method, three different methods of the absolute measurement were performed with a prepared 60 Co source to find excellent agreement among the results deduced by them. Next, the 4πβ-γ spectroscopic coincidence measurement was applied to 152 Eu sources prepared by irradiating an enriched 151 Eu target in a reactor. The result was compared with that obtained by the γ-ray spectrometry using a 152 Eu standard source supplied by LMRI. They agreed with each other within the error of 2%. (author)

  17. Absolute high-resolution Se+ photoionization cross-section measurements with Rydberg-series analysis

    International Nuclear Information System (INIS)

    Esteves, D. A.; Bilodeau, R. C.; Sterling, N. C.; Phaneuf, R. A.; Kilcoyne, A. L. D.; Red, E. C.; Aguilar, A.

    2011-01-01

    Absolute single photoionization cross-section measurements for Se + ions were performed at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory using the photo-ion merged-beams technique. Measurements were made at a photon energy resolution of 5.5 meV from 17.75 to 21.85 eV spanning the 4s 2 4p 3 4 S 3/2 o ground-state ionization threshold and the 2 P 3/2 o , 2 P 1/2 o , 2 D 5/2 o , and 2 D 3/2 o metastable state thresholds. Extensive analysis of the complex resonant structure in this region identified numerous Rydberg series of resonances and obtained the Se 2+ 4s 2 4p 23 P 2 and 4s 2 4p 21 S 0 state energies. In addition, particular attention was given to removing significant effects in the measurements due to a small percentage of higher-order undulator radiation.

  18. Threshold Signature Schemes Application

    Directory of Open Access Journals (Sweden)

    Anastasiya Victorovna Beresneva

    2015-10-01

    Full Text Available This work is devoted to an investigation of threshold signature schemes. The systematization of the threshold signature schemes was done, cryptographic constructions based on interpolation Lagrange polynomial, elliptic curves and bilinear pairings were examined. Different methods of generation and verification of threshold signatures were explored, the availability of practical usage of threshold schemes in mobile agents, Internet banking and e-currency was shown. The topics of further investigation were given and it could reduce a level of counterfeit electronic documents signed by a group of users.

  19. Particles near threshold

    International Nuclear Information System (INIS)

    Bhattacharya, T.; Willenbrock, S.

    1993-01-01

    We propose returning to the definition of the width of a particle in terms of the pole in the particle's propagator. Away from thresholds, this definition of width is equivalent to the standard perturbative definition, up to next-to-leading order; however, near a threshold, the two definitions differ significantly. The width as defined by the pole position provides more information in the threshold region than the standard perturbative definition and, in contrast with the perturbative definition, does not vanish when a two-particle s-wave threshold is approached from below

  20. Towards a unifying basis of auditory thresholds: binaural summation.

    Science.gov (United States)

    Heil, Peter

    2014-04-01

    Absolute auditory threshold decreases with increasing sound duration, a phenomenon explainable by the assumptions that the sound evokes neural events whose probabilities of occurrence are proportional to the sound's amplitude raised to an exponent of about 3 and that a constant number of events are required for threshold (Heil and Neubauer, Proc Natl Acad Sci USA 100:6151-6156, 2003). Based on this probabilistic model and on the assumption of perfect binaural summation, an equation is derived here that provides an explicit expression of the binaural threshold as a function of the two monaural thresholds, irrespective of whether they are equal or unequal, and of the exponent in the model. For exponents >0, the predicted binaural advantage is largest when the two monaural thresholds are equal and decreases towards zero as the monaural threshold difference increases. This equation is tested and the exponent derived by comparing binaural thresholds with those predicted on the basis of the two monaural thresholds for different values of the exponent. The thresholds, measured in a large sample of human subjects with equal and unequal monaural thresholds and for stimuli with different temporal envelopes, are compatible only with an exponent close to 3. An exponent of 3 predicts a binaural advantage of 2 dB when the two ears are equally sensitive. Thus, listening with two (equally sensitive) ears rather than one has the same effect on absolute threshold as doubling duration. The data suggest that perfect binaural summation occurs at threshold and that peripheral neural signals are governed by an exponent close to 3. They might also shed new light on mechanisms underlying binaural summation of loudness.

  1. Absolute efficiency calibration of HPGe detector by simulation method

    International Nuclear Information System (INIS)

    Narayani, K.; Pant, Amar D.; Verma, Amit K.; Bhosale, N.A.; Anilkumar, S.

    2018-01-01

    High resolution gamma ray spectrometry by HPGe detectors is a powerful radio analytical technique for estimation of activity of various radionuclides. In the present work absolute efficiency calibration of the HPGe detector was carried out using Monte Carlo simulation technique and results are compared with those obtained by experiment using standard radionuclides of 152 Eu and 133 Ba. The coincidence summing correction factors for the measurement of these nuclides were also calculated

  2. Is action potential threshold lowest in the axon?

    NARCIS (Netherlands)

    Kole, Maarten H. P.; Stuart, Greg J.

    2008-01-01

    Action potential threshold is thought to be lowest in the axon, but when measured using conventional techniques, we found that action potential voltage threshold of rat cortical pyramidal neurons was higher in the axon than at other neuronal locations. In contrast, both current threshold and voltage

  3. Double Photoionization Near Threshold

    Science.gov (United States)

    Wehlitz, Ralf

    2007-01-01

    The threshold region of the double-photoionization cross section is of particular interest because both ejected electrons move slowly in the Coulomb field of the residual ion. Near threshold both electrons have time to interact with each other and with the residual ion. Also, different theoretical models compete to describe the double-photoionization cross section in the threshold region. We have investigated that cross section for lithium and beryllium and have analyzed our data with respect to the latest results in the Coulomb-dipole theory. We find that our data support the idea of a Coulomb-dipole interaction.

  4. Thresholds in radiobiology

    International Nuclear Information System (INIS)

    Katz, R.; Hofmann, W.

    1982-01-01

    Interpretations of biological radiation effects frequently use the word 'threshold'. The meaning of this word is explored together with its relationship to the fundamental character of radiation effects and to the question of perception. It is emphasised that although the existence of either a dose or an LET threshold can never be settled by experimental radiobiological investigations, it may be argued on fundamental statistical grounds that for all statistical processes, and especially where the number of observed events is small, the concept of a threshold is logically invalid. (U.K.)

  5. Threshold of decay instability in an inhomogeneous plasma (Leningrad 1973)

    International Nuclear Information System (INIS)

    Piliia, A.D.

    It is shown that in a spatially inhomogeneous plasma there can exist an absolute decay instability with a threshold lower than that found earlier. This instability arises when two parametrically coupled waves have turning points inside the plasma layer. The cause of the instability is a positive inverse coupling, caused by a nonlinear conversion and a reflection of the waves

  6. Measurement of the Absolute Branching Fraction for Lambda(+)(c) -> Lambda e(+)nu(e)

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M.N.; Ai, X.C.; Albayrak, O.; Albrecht, M.; Ambrose, D.J.; Amorose, A.; Haddadi, Z.; Kalantar-Nayestanaki, Nasser; Kavatsyuk, M.; Messchendorp, J.G; Tiemens, M.

    2015-01-01

    We report the first measurement of the absolute branching fraction for Lambda(+)(c) -> Lambda e(+)nu(e). This measurement is based on 567 pb(-1) of e(+)e(-) annihilation data produced at root s = 4.599 GeV, which is just above the Lambda(+)(c)Lambda(-)(c) threshold. The data were collected with the

  7. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  8. Absolute photoionization cross section of the ethyl radical in the range 8-11.5 eV: synchrotron and vacuum ultraviolet laser measurements.

    Science.gov (United States)

    Gans, Bérenger; Garcia, Gustavo A; Boyé-Péronne, Séverine; Loison, Jean-Christophe; Douin, Stéphane; Gaie-Levrel, François; Gauyacq, Dolores

    2011-06-02

    The absolute photoionization cross section of C(2)H(5) has been measured at 10.54 eV using vacuum ultraviolet (VUV) laser photoionization. The C(2)H(5) radical was produced in situ using the rapid C(2)H(6) + F → C(2)H(5) + HF reaction. Its absolute photoionization cross section has been determined in two different ways: first using the C(2)H(5) + NO(2) → C(2)H(5)O + NO reaction in a fast flow reactor, and the known absolute photoionization cross section of NO. In a second experiment, it has been measured relative to the known absolute photoionization cross section of CH(3) as a reference by using the CH(4) + F → CH(3) + HF and C(2)H(6) + F → C(2)H(5) + HF reactions successively. Both methods gave similar results, the second one being more precise and yielding the value: σ(C(2)H(5))(ion) = (5.6 ± 1.4) Mb at 10.54 eV. This value is used to calibrate on an absolute scale the photoionization curve of C(2)H(5) produced in a pyrolytic source from the C(2)H(5)NO(2) precursor, and ionized by the VUV beam of the DESIRS beamline at SOLEIL synchrotron facility. In this latter experiment, a recently developed ion imaging technique is used to discriminate the direct photoionization process from dissociative ionization contributions to the C(2)H(5)(+) signal. The imaging technique applied on the photoelectron signal also allows a slow photoelectron spectrum with a 40 meV resolution to be extracted, indicating that photoionization around the adiabatic ionization threshold involves a complex vibrational overlap between the neutral and cationic ground states, as was previously observed in the literature. Comparison with earlier photoionization studies, in particular with the photoionization yield recorded by Ruscic et al. is also discussed. © 2011 American Chemical Society

  9. NEUTRON SPECTRUM MEASUREMENTS USING MULTIPLE THRESHOLD DETECTORS

    Energy Technology Data Exchange (ETDEWEB)

    Gerken, William W.; Duffey, Dick

    1963-11-15

    From American Nuclear Society Meeting, New York, Nov. 1963. The use of threshold detectors, which simultaneously undergo reactions with thermal neutrons and two or more fast neutron threshold reactions, was applied to measurements of the neutron spectrum in a reactor. A number of different materials were irradiated to determine the most practical ones for use as multiple threshold detectors. These results, as well as counting techniques and corrections, are presented. Some materials used include aluminum, alloys of Al -Ni, aluminum-- nickel oxides, and magesium orthophosphates. (auth)

  10. Regional Seismic Threshold Monitoring

    National Research Council Canada - National Science Library

    Kvaerna, Tormod

    2006-01-01

    ... model to be used for predicting the travel times of regional phases. We have applied these attenuation relations to develop and assess a regional threshold monitoring scheme for selected subregions of the European Arctic...

  11. Absolute entropy of ions in methanol

    International Nuclear Information System (INIS)

    Abakshin, V.A.; Kobenin, V.A.; Krestov, G.A.

    1978-01-01

    By measuring the initial thermoelectromotive forces of chains with bromo-silver electrodes in tetraalkylammonium bromide solutions the absolute entropy of bromide-ion in methanol is determined in the 298.15-318.15 K range. The anti Ssub(Brsup(-))sup(0) = 9.8 entropy units value is used for calculation of the absolute partial molar entropy of alkali metal ions and halogenide ions. It has been found that, absolute entropy of Cs + =12.0 entropy units, I - =14.0 entropy units. The obtained ion absolute entropies in methanol at 298.15 K within 1-2 entropy units is in an agreement with published data

  12. Absolute rate measurement by light modulation - ESR technique

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K Y; Gaspar, P P

    1977-01-01

    A rate constant is deduced for the reaction of tert-butoxy radicals and trimethylsilane from the measurement of the phase shift between the modulated light source and the ESR signal of trimethylsilyl radical. The rate constant was found to be 3 x 10/sup -2/M/sup -1/. sec/sup -1/ at -50/sup 0/C.

  13. A Simple Polarimetry Technique for Predicting the Absolute ...

    African Journals Online (AJOL)

    NICOLAAS

    2015-08-28

    Aug 28, 2015 ... The method involves simply measuring the optical rotation of the host-guest inclusion complex .... masses of the so-obtained complexes and analyzed these using ... In essence, if a given quantity of compound X rotates plane.

  14. Absolute Ca Isotopic Measurement Using an Improved Double Spike Technique

    Directory of Open Access Journals (Sweden)

    Jason Jiun-San Shen

    2009-01-01

    Full Text Available A new vector analytical method has been developed in order to obtain the true isotopic composition of the 42Ca-48Ca double spike. This is achieved by using two different sample-spike mixtures combined with the double spike and natural Ca data. Be cause the natural sample (two mixtures and the spike should all lie on a single mixing line, we are able to con strain the true isotopic composition of our double spike using this new approach. Once the isotopic composition of the Ca double spike is established, we are able to obtain the true Ca isotopic composition of the NIST Ca standard SRM915a, 40Ca/44Ca = 46.537 ± 2 (2sm, n = 55, 42Ca/44Ca = 0.31031 ± 1, 43Ca/44Ca = 0.06474 ± 1, and 48Ca/44Ca = 0.08956 ± 1. De spite an off set of 1.3% in 40Ca/44Ca between our result and the previously re ported value (Russell et al. 1978, our data indicate an off set of 1.89__in 40Ca/44Ca between SRM915a and seawater, entirely consistent with the published results.

  15. A Novel Compressed Sensing Method for Magnetic Resonance Imaging: Exponential Wavelet Iterative Shrinkage-Thresholding Algorithm with Random Shift

    Directory of Open Access Journals (Sweden)

    Yudong Zhang

    2016-01-01

    Full Text Available Aim. It can help improve the hospital throughput to accelerate magnetic resonance imaging (MRI scanning. Patients will benefit from less waiting time. Task. In the last decade, various rapid MRI techniques on the basis of compressed sensing (CS were proposed. However, both computation time and reconstruction quality of traditional CS-MRI did not meet the requirement of clinical use. Method. In this study, a novel method was proposed with the name of exponential wavelet iterative shrinkage-thresholding algorithm with random shift (abbreviated as EWISTARS. It is composed of three successful components: (i exponential wavelet transform, (ii iterative shrinkage-thresholding algorithm, and (iii random shift. Results. Experimental results validated that, compared to state-of-the-art approaches, EWISTARS obtained the least mean absolute error, the least mean-squared error, and the highest peak signal-to-noise ratio. Conclusion. EWISTARS is superior to state-of-the-art approaches.

  16. A Novel Compressed Sensing Method for Magnetic Resonance Imaging: Exponential Wavelet Iterative Shrinkage-Thresholding Algorithm with Random Shift

    Science.gov (United States)

    Zhang, Yudong; Yang, Jiquan; Yang, Jianfei; Liu, Aijun; Sun, Ping

    2016-01-01

    Aim. It can help improve the hospital throughput to accelerate magnetic resonance imaging (MRI) scanning. Patients will benefit from less waiting time. Task. In the last decade, various rapid MRI techniques on the basis of compressed sensing (CS) were proposed. However, both computation time and reconstruction quality of traditional CS-MRI did not meet the requirement of clinical use. Method. In this study, a novel method was proposed with the name of exponential wavelet iterative shrinkage-thresholding algorithm with random shift (abbreviated as EWISTARS). It is composed of three successful components: (i) exponential wavelet transform, (ii) iterative shrinkage-thresholding algorithm, and (iii) random shift. Results. Experimental results validated that, compared to state-of-the-art approaches, EWISTARS obtained the least mean absolute error, the least mean-squared error, and the highest peak signal-to-noise ratio. Conclusion. EWISTARS is superior to state-of-the-art approaches. PMID:27066068

  17. The gradual nature of threshold switching

    International Nuclear Information System (INIS)

    Wimmer, M; Salinga, M

    2014-01-01

    The recent commercialization of electronic memories based on phase change materials proved the usability of this peculiar family of materials for application purposes. More advanced data storage and computing concepts, however, demand a deeper understanding especially of the electrical properties of the amorphous phase and the switching behaviour. In this work, we investigate the temporal evolution of the current through the amorphous state of the prototypical phase change material, Ge 2 Sb 2 Te 5 , under constant voltage. A custom-made electrical tester allows the measurement of delay times over five orders of magnitude, as well as the transient states of electrical excitation prior to the actual threshold switching. We recognize a continuous current increase over time prior to the actual threshold-switching event to be a good measure for the electrical excitation. A clear correlation between a significant rise in pre-switching-current and the later occurrence of threshold switching can be observed. This way, we found experimental evidence for the existence of an absolute minimum for the threshold voltage (or electric field respectively) holding also for time scales far beyond the measurement range. (paper)

  18. Threshold guidance update

    International Nuclear Information System (INIS)

    Wickham, L.E.

    1986-01-01

    The Department of Energy (DOE) is developing the concept of threshold quantities for use in determining which waste materials must be handled as radioactive waste and which may be disposed of as nonradioactive waste at its sites. Waste above this concentration level would be managed as radioactive or mixed waste (if hazardous chemicals are present); waste below this level would be handled as sanitary waste. Last years' activities (1984) included the development of a threshold guidance dose, the development of threshold concentrations corresponding to the guidance dose, the development of supporting documentation, review by a technical peer review committee, and review by the DOE community. As a result of the comments, areas have been identified for more extensive analysis, including an alternative basis for selection of the guidance dose and the development of quality assurance guidelines. Development of quality assurance guidelines will provide a reasonable basis for determining that a given waste stream qualifies as a threshold waste stream and can then be the basis for a more extensive cost-benefit analysis. The threshold guidance and supporting documentation will be revised, based on the comments received. The revised documents will be provided to DOE by early November. DOE-HQ has indicated that the revised documents will be available for review by DOE field offices and their contractors

  19. Introducing the Mean Absolute Deviation "Effect" Size

    Science.gov (United States)

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  20. Investigating Absolute Value: A Real World Application

    Science.gov (United States)

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  1. Measurement of the 235 U absolute activity

    International Nuclear Information System (INIS)

    Bueno, C.C.; Santos, M.D.S.

    1993-01-01

    The absolute activity of 235 U contained in a sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles emitted simultaneously with the 143 KeV gamma radiations from the 231 Th (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a 1'x 1 1/2 Nal (TI) scintillation detector. The value obtained for the half-life of 235 U, (7.04+-0.01)10 8 y, was compared with the data available from various observers with used different experimental techniques. It is shown that our results are in excellent agreement with the best data available on the subject. (author) 15 refs, 5 figs, 1 tab

  2. Single event upset threshold estimation based on local laser irradiation

    International Nuclear Information System (INIS)

    Chumakov, A.I.; Egorov, A.N.; Mavritsky, O.B.; Yanenko, A.V.

    1999-01-01

    An approach for estimation of ion-induced SEU threshold based on local laser irradiation is presented. Comparative experiment and software simulation research were performed at various pulse duration and spot size. Correlation of single event threshold LET to upset threshold laser energy under local irradiation was found. The computer analysis of local laser irradiation of IC structures was developed for SEU threshold LET estimation. The correlation of local laser threshold energy with SEU threshold LET was shown. Two estimation techniques were suggested. The first one is based on the determination of local laser threshold dose taking into account the relation of sensitive area to local irradiated area. The second technique uses the photocurrent peak value instead of this relation. The agreement between the predicted and experimental results demonstrates the applicability of this approach. (authors)

  3. Hyper-arousal decreases human visual thresholds.

    Directory of Open Access Journals (Sweden)

    Adam J Woods

    Full Text Available Arousal has long been known to influence behavior and serves as an underlying component of cognition and consciousness. However, the consequences of hyper-arousal for visual perception remain unclear. The present study evaluates the impact of hyper-arousal on two aspects of visual sensitivity: visual stereoacuity and contrast thresholds. Sixty-eight participants participated in two experiments. Thirty-four participants were randomly divided into two groups in each experiment: Arousal Stimulation or Sham Control. The Arousal Stimulation group underwent a 50-second cold pressor stimulation (immersing the foot in 0-2° C water, a technique known to increase arousal. In contrast, the Sham Control group immersed their foot in room temperature water. Stereoacuity thresholds (Experiment 1 and contrast thresholds (Experiment 2 were measured before and after stimulation. The Arousal Stimulation groups demonstrated significantly lower stereoacuity and contrast thresholds following cold pressor stimulation, whereas the Sham Control groups showed no difference in thresholds. These results provide the first evidence that hyper-arousal from sensory stimulation can lower visual thresholds. Hyper-arousal's ability to decrease visual thresholds has important implications for survival, sports, and everyday life.

  4. Absolute elastic cross sections for electron scattering from SF6

    International Nuclear Information System (INIS)

    Gulley, R.J.; Uhlmann, L.J.; Dedman, C.J.; Buckman, S.J.; Cho, H.; Trantham, K.W.

    2000-01-01

    Full text: Absolute differential cross sections for vibrationally elastic scattering of electrons from sulphur hexafluoride (SF 6 ) have been measured at fixed angles of 60 deg, 90 deg and 120 deg over the energy range of 5 to 15 eV, and also at 11 fixed energies between 2.7 and 75 eV for scattering angles between 10 deg and 180 deg. These measurements employ the magnetic angle-changing technique of Read and Channing in combination with the relative flow technique to obtain absolute elastic scattering cross sections at backward angles (135 deg to 180 deg) for incident energies below 15 eV. The results reveal some substantial differences with several previous determinations and a reasonably good level of agreement with a recent close coupling calculation

  5. Orion Absolute Navigation System Progress and Challenge

    Science.gov (United States)

    Holt, Greg N.; D'Souza, Christopher

    2012-01-01

    The absolute navigation design of NASA's Orion vehicle is described. It has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary onboard measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudo-range and delta-range, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, and cold start are discussed as are strategies for whole and partial state updates as well as covariance considerations. Strategies are given for dealing with latent measurements and high-rate propagation using multi-rate architecture. The details of the rate groups and the data ow between the elements is discussed and evaluated.

  6. Robust Adaptive Thresholder For Document Scanning Applications

    Science.gov (United States)

    Hsing, To R.

    1982-12-01

    In document scanning applications, thresholding is used to obtain binary data from a scanner. However, due to: (1) a wide range of different color backgrounds; (2) density variations of printed text information; and (3) the shading effect caused by the optical systems, the use of adaptive thresholding to enhance the useful information is highly desired. This paper describes a new robust adaptive thresholder for obtaining valid binary images. It is basically a memory type algorithm which can dynamically update the black and white reference level to optimize a local adaptive threshold function. The results of high image quality from different types of simulate test patterns can be obtained by this algorithm. The software algorithm is described and experiment results are present to describe the procedures. Results also show that the techniques described here can be used for real-time signal processing in the varied applications.

  7. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  8. A global algorithm for estimating Absolute Salinity

    Science.gov (United States)

    McDougall, T. J.; Jackett, D. R.; Millero, F. J.; Pawlowicz, R.; Barker, P. M.

    2012-12-01

    The International Thermodynamic Equation of Seawater - 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density) than does Practical Salinity. When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic), Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg-1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p) in the world ocean. To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811). In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally).

  9. Threshold factorization redux

    Science.gov (United States)

    Chay, Junegone; Kim, Chul

    2018-05-01

    We reanalyze the factorization theorems for the Drell-Yan process and for deep inelastic scattering near threshold, as constructed in the framework of the soft-collinear effective theory (SCET), from a new, consistent perspective. In order to formulate the factorization near threshold in SCET, we should include an additional degree of freedom with small energy, collinear to the beam direction. The corresponding collinear-soft mode is included to describe the parton distribution function (PDF) near threshold. The soft function is modified by subtracting the contribution of the collinear-soft modes in order to avoid double counting on the overlap region. As a result, the proper soft function becomes infrared finite, and all the factorized parts are free of rapidity divergence. Furthermore, the separation of the relevant scales in each factorized part becomes manifest. We apply the same idea to the dihadron production in e+e- annihilation near threshold, and show that the resultant soft function is also free of infrared and rapidity divergences.

  10. Elaborating on Threshold Concepts

    Science.gov (United States)

    Rountree, Janet; Robins, Anthony; Rountree, Nathan

    2013-01-01

    We propose an expanded definition of Threshold Concepts (TCs) that requires the successful acquisition and internalisation not only of knowledge, but also its practical elaboration in the domains of applied strategies and mental models. This richer definition allows us to clarify the relationship between TCs and Fundamental Ideas, and to account…

  11. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Pie Valls, B; Pietrzyk, B; Pilar, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; du Pree, T; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shao, B; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skottowe, H P; Skwarnicki, T; Smith, A C; Smith, N A; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Styles, N; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Vervink, K; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Voong, D; Vorobyev, A; Voss, H; Wacker, K; Wandernoth, S; Wang, J; Ward, D R; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  12. The absolute environmental performance of buildings

    DEFF Research Database (Denmark)

    Brejnrod, Kathrine Nykjær; Kalbar, Pradip; Petersen, Steffen

    2017-01-01

    Our paper presents a novel approach for absolute sustainability assessment of a building's environmental performance. It is demonstrated how the absolute sustainable share of the earth carrying capacity of a specific building type can be estimated using carrying capacity based normalization factors....... A building is considered absolute sustainable if its annual environmental burden is less than its share of the earth environmental carrying capacity. Two case buildings – a standard house and an upcycled single-family house located in Denmark – were assessed according to this approach and both were found...... to exceed the target values of three (almost four) of the eleven impact categories included in the study. The worst-case excess was for the case building, representing prevalent Danish building practices, which utilized 1563% of the Climate Change carrying capacity. Four paths to reach absolute...

  13. A real space calculation of absolutely unstable modes for two-plasmon decay in inhomogeneous plasma

    International Nuclear Information System (INIS)

    Powers, L.V.; Berger, R.L.

    1986-01-01

    Growth rates for absolute modes of two-plasmon decay are obtained by solving for eigenmodes of the coupled mode equations for obliquely scattered Langmuir waves in real space. This analysis establishes a connection both to previous analysis in Fourier transform space and to other parametric instabilities, the analysis of which is commonly done in real space. The essential feature of the instability which admits absolute modes in an inhomogeneous plasma is the strong spatial dependence of the coupling coefficients. Landau damping limits the perpendicular wavenumbers of the most unstable modes and raises the instability thresholds for background plasma temperatures above 1 keV. (author)

  14. Absolute cross-section measurements of inner-shell ionization

    Science.gov (United States)

    Schneider, Hans; Tobehn, Ingo; Ebel, Frank; Hippler, Rainer

    1994-12-01

    Cross section ratios for K- and L-shell ionization of thin silver and gold targets by positron and electron impact have been determined at projectile energies of 30 70 keV. The experimental results are confirmed by calculations in plane wave Born approximation (PWBA) which include an electron exchange term and account for the deceleration or acceleration of the incident projectile in the nuclear field of the target atom. We report first absolute cross sections for K- and L-shell ionization of silver and gold targets by lepton impact in the threshold region. We have measured the corresponding cross sections for electron (e-) impact with an electron gun and the same experimental set-up.

  15. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  16. Thresholding methods for PET imaging: A review

    International Nuclear Information System (INIS)

    Dewalle-Vignion, A.S.; Betrouni, N.; Huglo, D.; Vermandel, M.; Dewalle-Vignion, A.S.; Hossein-Foucher, C.; Huglo, D.; Vermandel, M.; Dewalle-Vignion, A.S.; Hossein-Foucher, C.; Huglo, D.; Vermandel, M.; El Abiad, A.

    2010-01-01

    This work deals with positron emission tomography segmentation methods for tumor volume determination. We propose a state of art techniques based on fixed or adaptive threshold. Methods found in literature are analysed with an objective point of view on their methodology, advantages and limitations. Finally, a comparative study is presented. (authors)

  17. Sub-threshold excited Cl Kβ (K-V) x-ray fluorescence from CF3Cl molecule

    International Nuclear Information System (INIS)

    Perera, R.C.C.; Cowan, P.L.; Lindle, D.W.; LaVilla, R.E.

    1987-10-01

    With the availability of tunable synchrotron radiation sources, unoccupied molecular orbits (below vacuum level) can be selectively populated producing highly excited neutral molecules. X-ray fluorescence spectra from molecules were obtained with excitation below the ionization threshold and were observed to have significant intensity changes, absolute and relative energy position shifts and line width changes as compared to fluorescence spectra excited above the threshold. As an example, the Cl Kβ (K-V) emission spectra from CF 3 Cl vapor are presented. The energy shifts and intensity changes are explained in terms of perturbation effects due to the presence of an electron in an unoccupied molecular orbital. The narrow line widths obtained in the spectra excited below threshold are explained in terms of the ''effective'' hole production region in a core state limited by the broadening of the unoccupied level. The change in line widths as a function of below-threshold excitation energy is proposed as a novel technique to study the localized properties and reorganization effects of a hole in a core level. 10 refs., 4 figs., 1 tab

  18. Hadron production near threshold

    Indian Academy of Sciences (India)

    Abstract. Final state interaction effects in pp → pΛK+ and pd → 3He η reactions are explored near threshold to study the sensitivity of the cross-sections to the pΛ potential and the ηN scattering matrix. The final state scattering wave functions between Λ and p and η and 3He are described rigorously. The Λ production is ...

  19. Casualties and threshold effects

    International Nuclear Information System (INIS)

    Mays, C.W.; National Cancer Inst., Bethesda

    1988-01-01

    Radiation effects like cancer are denoted as casualties. Other radiation effects occur almost in everyone when the radiation dose is sufficiently high. One then speaks of radiation effects with a threshold dose. In this article the author puts his doubt about this classification of radiation effects. He argues that some effects of exposure to radiation do not fit in this classification. (H.W.). 19 refs.; 2 figs.; 1 tab

  20. Resonance phenomena near thresholds

    International Nuclear Information System (INIS)

    Persson, E.; Mueller, M.; Rotter, I.; Technische Univ. Dresden

    1995-12-01

    The trapping effect is investigated close to the elastic threshold. The nucleus is described as an open quantum mechanical many-body system embedded in the continuum of decay channels. An ensemble of compound nucleus states with both discrete and resonance states is investigated in an energy-dependent formalism. It is shown that the discrete states can trap the resonance ones and also that the discrete states can directly influence the scattering cross section. (orig.)

  1. Hemispheric lateralization of motor thresholds in relation to stuttering.

    Directory of Open Access Journals (Sweden)

    Per A Alm

    Full Text Available Stuttering is a complex speech disorder. Previous studies indicate a tendency towards elevated motor threshold for the left hemisphere, as measured using transcranial magnetic stimulation (TMS. This may reflect a monohemispheric motor system impairment. The purpose of the study was to investigate the relative side-to-side difference (asymmetry and the absolute levels of motor threshold for the hand area, using TMS in adults who stutter (n = 15 and in controls (n = 15. In accordance with the hypothesis, the groups differed significantly regarding the relative side-to-side difference of finger motor threshold (p = 0.0026, with the stuttering group showing higher motor threshold of the left hemisphere in relation to the right. Also the absolute level of the finger motor threshold for the left hemisphere differed between the groups (p = 0.049. The obtained results, together with previous investigations, provide support for the hypothesis that stuttering tends to be related to left hemisphere motor impairment, and possibly to a dysfunctional state of bilateral speech motor control.

  2. Hemispheric Lateralization of Motor Thresholds in Relation to Stuttering

    Science.gov (United States)

    Alm, Per A.; Karlsson, Ragnhild; Sundberg, Madeleine; Axelson, Hans W.

    2013-01-01

    Stuttering is a complex speech disorder. Previous studies indicate a tendency towards elevated motor threshold for the left hemisphere, as measured using transcranial magnetic stimulation (TMS). This may reflect a monohemispheric motor system impairment. The purpose of the study was to investigate the relative side-to-side difference (asymmetry) and the absolute levels of motor threshold for the hand area, using TMS in adults who stutter (n = 15) and in controls (n = 15). In accordance with the hypothesis, the groups differed significantly regarding the relative side-to-side difference of finger motor threshold (p = 0.0026), with the stuttering group showing higher motor threshold of the left hemisphere in relation to the right. Also the absolute level of the finger motor threshold for the left hemisphere differed between the groups (p = 0.049). The obtained results, together with previous investigations, provide support for the hypothesis that stuttering tends to be related to left hemisphere motor impairment, and possibly to a dysfunctional state of bilateral speech motor control. PMID:24146930

  3. Remote ultrasound palpation for robotic interventions using absolute elastography.

    Science.gov (United States)

    Schneider, Caitlin; Baghani, Ali; Rohling, Robert; Salcudean, Septimiu

    2012-01-01

    Although robotic surgery has addressed many of the challenges presented by minimally invasive surgery, haptic feedback and the lack of knowledge of tissue stiffness is an unsolved problem. This paper presents a system for finding the absolute elastic properties of tissue using a freehand ultrasound scanning technique, which utilizes the da Vinci Surgical robot and a custom 2D ultrasound transducer for intraoperative use. An external exciter creates shear waves in the tissue, and a local frequency estimation method computes the shear modulus. Results are reported for both phantom and in vivo models. This system can be extended to any 6 degree-of-freedom tracking method and any 2D transducer to provide real-time absolute elastic properties of tissue.

  4. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  5. Comparison between intensity- duration thresholds and cumulative rainfall thresholds for the forecasting of landslide

    Science.gov (United States)

    Lagomarsino, Daniela; Rosi, Ascanio; Rossi, Guglielmo; Segoni, Samuele; Catani, Filippo

    2014-05-01

    This work makes a quantitative comparison between the results of landslide forecasting obtained using two different rainfall threshold models, one using intensity-duration thresholds and the other based on cumulative rainfall thresholds in an area of northern Tuscany of 116 km2. The first methodology identifies rainfall intensity-duration thresholds by means a software called MaCumBA (Massive CUMulative Brisk Analyzer) that analyzes rain-gauge records, extracts the intensities (I) and durations (D) of the rainstorms associated with the initiation of landslides, plots these values on a diagram, and identifies thresholds that define the lower bounds of the I-D values. A back analysis using data from past events can be used to identify the threshold conditions associated with the least amount of false alarms. The second method (SIGMA) is based on the hypothesis that anomalous or extreme values of rainfall are responsible for landslide triggering: the statistical distribution of the rainfall series is analyzed, and multiples of the standard deviation (σ) are used as thresholds to discriminate between ordinary and extraordinary rainfall events. The name of the model, SIGMA, reflects the central role of the standard deviations in the proposed methodology. The definition of intensity-duration rainfall thresholds requires the combined use of rainfall measurements and an inventory of dated landslides, whereas SIGMA model can be implemented using only rainfall data. These two methodologies were applied in an area of 116 km2 where a database of 1200 landslides was available for the period 2000-2012. The results obtained are compared and discussed. Although several examples of visual comparisons between different intensity-duration rainfall thresholds are reported in the international literature, a quantitative comparison between thresholds obtained in the same area using different techniques and approaches is a relatively undebated research topic.

  6. The threshold photoelectron spectrum of mercury

    International Nuclear Information System (INIS)

    Rojas, H; Dawber, G; Gulley, N; King, G C; Bowring, N; Ward, R

    2013-01-01

    The threshold photoelectron spectrum of mercury has been recorded over the energy range (10–40 eV) which covers the region from the lowest state of the singly charged ion, 5d 10 6s( 2 S 1/2 ), to the double charged ionic state, 5d 9 ( 2 D 3/2 )6s( 1 D 2 ). Synchrotron radiation has been used in conjunction with the penetrating-field threshold-electron technique to obtain the spectrum with high resolution. The spectrum shows many more features than observed in previous photoemission measurements with many of these assigned to satellite states converging to the double ionization limit. (paper)

  7. Absolute isotopic abundances of Ti in meteorites

    International Nuclear Information System (INIS)

    Niederer, F.R.; Papanastassiou, D.A.; Wasserburg, G.J.

    1985-01-01

    The absolute isotope abundance of Ti has been determined in Ca-Al-rich inclusions from the Allende and Leoville meteorites and in samples of whole meteorites. The absolute Ti isotope abundances differ by a significant mass dependent isotope fractionation transformation from the previously reported abundances, which were normalized for fractionation using 46 Ti/ 48 Ti. Therefore, the absolute compositions define distinct nucleosynthetic components from those previously identified or reflect the existence of significant mass dependent isotope fractionation in nature. We provide a general formalism for determining the possible isotope compositions of the exotic Ti from the measured composition, for different values of isotope fractionation in nature and for different mixing ratios of the exotic and normal components. The absolute Ti and Ca isotopic compositions still support the correlation of 50 Ti and 48 Ca effects in the FUN inclusions and imply contributions from neutron-rich equilibrium or quasi-equilibrium nucleosynthesis. The present identification of endemic effects at 46 Ti, for the absolute composition, implies a shortfall of an explosive-oxygen component or reflects significant isotope fractionation. Additional nucleosynthetic components are required by 47 Ti and 49 Ti effects. Components are also defined in which 48 Ti is enhanced. Results are given and discussed. (author)

  8. Bound-Electron Nonlinearity Beyond the Ionization Threshold

    Science.gov (United States)

    Wahlstrand, J. K.; Zahedpour, S.; Bahl, A.; Kolesik, M.; Milchberg, H. M.

    2018-05-01

    We present absolute space- and time-resolved measurements of the ultrafast laser-driven nonlinear polarizability in argon, krypton, xenon, nitrogen, and oxygen up to ionization fractions of a few percent. These measurements enable determination of the strongly nonperturbative bound-electron nonlinear polarizability well beyond the ionization threshold, where it is found to remain approximately quadratic in the laser field, a result normally expected at much lower intensities where perturbation theory applies.

  9. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  10. Intermediate structure and threshold phenomena

    International Nuclear Information System (INIS)

    Hategan, Cornel

    2004-01-01

    The Intermediate Structure, evidenced through microstructures of the neutron strength function, is reflected in open reaction channels as fluctuations in excitation function of nuclear threshold effects. The intermediate state supporting both neutron strength function and nuclear threshold effect is a micro-giant neutron threshold state. (author)

  11. thresholds of gully erosion in the coastal plains sands of ...

    African Journals Online (AJOL)

    Ada

    estimating thresholds for gully initiation and sustenance. The entire 413. Km2 Ikpa River basin was covered with grids 1km2 and random number table was used to select 15% of the target population in the basin. The pair-wise correlation technique was employed to establish the threshold values of vegetation cover, organic ...

  12. Coloring geographical threshold graphs

    Energy Technology Data Exchange (ETDEWEB)

    Bradonjic, Milan [Los Alamos National Laboratory; Percus, Allon [Los Alamos National Laboratory; Muller, Tobias [EINDHOVEN UNIV. OF TECH

    2008-01-01

    We propose a coloring algorithm for sparse random graphs generated by the geographical threshold graph (GTG) model, a generalization of random geometric graphs (RGG). In a GTG, nodes are distributed in a Euclidean space, and edges are assigned according to a threshold function involving the distance between nodes as well as randomly chosen node weights. The motivation for analyzing this model is that many real networks (e.g., wireless networks, the Internet, etc.) need to be studied by using a 'richer' stochastic model (which in this case includes both a distance between nodes and weights on the nodes). Here, we analyze the GTG coloring algorithm together with the graph's clique number, showing formally that in spite of the differences in structure between GTG and RGG, the asymptotic behavior of the chromatic number is identical: {chi}1n 1n n / 1n n (1 + {omicron}(1)). Finally, we consider the leading corrections to this expression, again using the coloring algorithm and clique number to provide bounds on the chromatic number. We show that the gap between the lower and upper bound is within C 1n n / (1n 1n n){sup 2}, and specify the constant C.

  13. Redetermination and absolute configuration of atalaphylline

    Directory of Open Access Journals (Sweden)

    Hoong-Kun Fun

    2010-02-01

    Full Text Available The title acridone alkaloid [systematic name: 1,3,5-trihydroxy-2,4-bis(3-methylbut-2-enylacridin-9(10H-one], C23H25NO4, has previously been reported as crystallizing in the chiral orthorhombic space group P212121 [Chantrapromma et al. (2010. Acta Cryst. E66, o81–o82] but the absolute configuration could not be determined from data collected with Mo radiation. The absolute configuration has now been determined by refinement of the Flack parameter with data collected using Cu radiation. All features of the molecule and its crystal packing are similar to those previously described.

  14. Absolute total cross sections for noble gas systems

    International Nuclear Information System (INIS)

    Kam, P. van der.

    1981-01-01

    This thesis deals with experiments on the elastic scattering of Ar, Kr and Xe, using the molecular beam technique. The aim of this work was the measurement of the absolute value of the total cross section and the behaviour of the total cross section, Q, as function of the relative velocity g of the scattering partners. The author gives an extensive analysis of the glory structure in the total cross section and parametrizes the experimental results using a semiclassical model function. This allows a detailed comparison of the phase and amplitude of the predicted and measured glory undulations. He indicates how the depth and position of the potential well should be changed in order to come to an optimum description of the glory structure. With this model function he has also been able to separate the glory and attractive contribution to Q, and using the results from the extrapolation measurements he has obtained absolute values for Qsub(a). From these absolute values he has calculated the parameter C 6 that determines the strength of the attractive region of the potential. In two of the four investigated gas combinations the obtained values lie outside the theoretical bounds. (Auth.)

  15. Deuteron threshold electrodisintegration at high momentum transfer

    International Nuclear Information System (INIS)

    Schmitt, W.M.; Turchinetz, W.; Williamson, C.F.; Yates, T.C.; Zumbro, J.D.; Lee, K.S.; Baghaei, H.; Churchwell, S.; Hicks, R.S.; Miskimen, R.; Peterson, G.A.; Wang, K.; Bosted, P.E.; Spengos, M.; Frois, B.; Martino, J.; Platchkov, S.; Hotta, A.

    1997-01-01

    Absolute differential cross sections for the threshold electrodisintegration of the deuteron with good resolution were measured at a laboratory scattering angle of 160 degree for five values of Q 2 ranging from 8.66 to 42.4fm -2 . Comparisons of the data averaged over E np from 0 to 3 MeV and from 0 to 10 MeV are made with nonrelativistic meson exchange calculations. These calculations are sensitive to the nucleon electromagnetic form factors, nucleon-nucleon potential, and relativistic effects. The data are also compared with a hybrid quark-hadron model calculation that describes the deuteron as a six-quark cluster for the short range part of the interaction. Some of these calculations can describe the data reasonably well over certain ranges of Q 2 ; however, none of these calculations can accurately describe the data over the entire measured Q 2 range. copyright 1997 The American Physical Society

  16. Deuteron threshold electrodisintegration at high momentum transfer

    International Nuclear Information System (INIS)

    Schmitt, W.M.; Turchinetz, W.; Williamson, C.F.

    1997-01-01

    Absolute differential cross sections for the threshold electrodisintegration of the deuteron with good resolution were measured at a laboratory scattering angle of 160 degree for five values of Q 2 ranging from 8.66 to 42.4 fm -2 . Comparisons of the data averaged over E np from 0--3 MeV and 0--10 MeV are made with nonrelativistic meson-exchange calculations. These calculations are sensitive to the nucleon electromagnetic form factors, nucleon-nucleon potential, and relativistic effects. The data are also compared with a hybrid quark-hadron model calculation that describes the deuteron as a six-quark cluster for the short range part of the interaction. Some of these calculations can describe the data reasonably well over certain ranges of Q 2 ; however, none of these calculations can accurately describe the data over the entire measured Q 2 range

  17. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    Science.gov (United States)

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  18. 3D measurement of absolute radiation dose in grid therapy

    International Nuclear Information System (INIS)

    Trapp, J V; Warrington, A P; Partridge, M; Philps, A; Leach, M O; Webb, S

    2004-01-01

    Spatially fractionated radiotherapy through a grid is a concept which has a long history and was routinely used in orthovoltage radiation therapy in the middle of last century to minimize damage to the skin and subcutaneous tissue. With the advent of megavoltage radiotherapy and its skin sparing effects the use of grids in radiotherapy declined in the 1970s. However there has recently been a revival of the technique for use in palliative treatments with a single fraction of 10 to 20 Gy. In this work the absolute 3D dose distribution in a grid irradiation is measured for photons using a combination of film and gel dosimetry

  19. Det demokratiske argument for absolut ytringsfrihed

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2014-01-01

    Artiklen diskuterer den påstand, at absolut ytringsfrihed er en nødvendig forudsætning for demokratisk legitimitet med udgangspunkt i en rekonstruktion af et argument fremsat af Ronald Dworkin. Spørgsmålet er, hvorfor ytringsfrihed skulle være en forudsætning for demokratisk legitimitet, og hvorfor...

  20. Musical Activity Tunes Up Absolute Pitch Ability

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Ribe, Lars Riisgaard

    2014-01-01

    Absolute pitch (AP) is the ability to identify or produce pitches of musical tones without an external reference. Active AP (i.e., pitch production or pitch adjustment) and passive AP (i.e., pitch identification) are considered to not necessarily coincide, although no study has properly compared...

  1. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  2. Absolute measurement of a tritium standard

    International Nuclear Information System (INIS)

    Hadzisehovic, M.; Mocilnik, I.; Buraei, K.; Pongrac, S.; Milojevic, A.

    1978-01-01

    For the determination of a tritium absolute activity standard, a method of internal gas counting has been used. The procedure involves water reduction by uranium and zinc further the measurement of the absolute disintegration rate of tritium per unit of the effective volume of the counter by a compensation method. Criteria for the choice of methods and procedures concerning the determination and measurement of gaseous 3 H yield, parameters of gaseous hydrogen, sample mass of HTO and the absolute disintegration rate of tritium are discussed. In order to obtain gaseous sources of 3 H (and 2 H), the same reversible chemical reaction was used, namely, the water - uranium hydride - hydrogen system. This reaction was proved to be quantitative above 500 deg C by measuring the yield of the gas obtained and the absolute activity of an HTO standard. A brief description of the measuring apparatus is given, as well as a critical discussion of the brass counter quality and the possibility of obtaining equal working conditions at the counter ends. (T.G.)

  3. Absolutyzm i pluralizm (ABSOLUTISM AND PLURALISM

    Directory of Open Access Journals (Sweden)

    Renata Ziemińska

    2005-06-01

    Full Text Available Alethic absolutism is a thesis that propositions can not be more or less true, that they are true or false for ever (if true at all and that their truth is independent on any circumstances of their assertion. In negative version, easier to defend, alethic absolutism claims the very same proposition can not be both true and false relative to circumstances of its assertion. Simple alethic pluralism is a thesis that we have many concepts of truth. It is a very good way to dissolve the controversy between alethic relativism and absolutism. Many philosophical concepts of truth are the best reason for such pluralism. If concept is meaning of a name, we have many concepts of truth because the name 'truth' was understood in many ways. The variety of meanings however can be superficial. Under it we can find one idea of truth expressed in correspondence truism or schema (T. The content of the truism is too poor to be content of anyone concept of truth, so it usually is connected with some picture of the world (ontology and we have so many concepts of truth as many pictures of the world. The authoress proposes the hierarchical pluralism with privileged classic (or correspondence in weak sense concept of truth as absolute property.Other author's publications:

  4. Absolute Distance Measurements with Tunable Semiconductor Laser

    Czech Academy of Sciences Publication Activity Database

    Mikel, Břetislav; Číp, Ondřej; Lazar, Josef

    T118, - (2005), s. 41-44 ISSN 0031-8949 R&D Projects: GA AV ČR(CZ) IAB2065001 Keywords : tunable laser * absolute interferometer Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  5. Thin-film magnetoresistive absolute position detector

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1990-01-01

    The subject of this thesis is the investigation of a digital absolute posi- tion-detection system, which is based on a position-information carrier (i.e. a magnetic tape) with one single code track on the one hand, and an array of magnetoresistive sensors for the detection of the information on the

  6. Stimulus Probability Effects in Absolute Identification

    Science.gov (United States)

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  7. Absolute tightness: the chemists hesitate to invest

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The safety requirements of industries as nuclear plants and the strengthening of regulations in the field of environment (more particularly those related to volatile organic compounds) have lead the manufacturers to build absolute tightness pumps. But these equipments do not answer all the problems and represent a high investment cost. In consequence, the chemists hesitate to invest. (O.L.)

  8. Solving Absolute Value Equations Algebraically and Geometrically

    Science.gov (United States)

    Shiyuan, Wei

    2005-01-01

    The way in which students can improve their comprehension by understanding the geometrical meaning of algebraic equations or solving algebraic equation geometrically is described. Students can experiment with the conditions of the absolute value equation presented, for an interesting way to form an overall understanding of the concept.

  9. Crossing the Petawatt threshold

    International Nuclear Information System (INIS)

    Perry, M.

    1996-01-01

    A revolutionary new laser called the Petawatt, developed by Lawrence Livermore researchers after an intensive three-year development effort, has produced more than 1,000 trillion (open-quotes petaclose quotes) watts of power, a world record. By crossing the petawatt threshold, the extraordinarily powerful laser heralds a new age in laser research. Lasers that provide a petawatt of power or more in a picosecond may make it possible to achieve fusion using significantly less energy than currently envisioned, through a novel Livermore concept called open-quotes fast ignition.close quotes The petawatt laser will also enable researchers to study the fundamental properties of matter, thereby aiding the Department of Energy's Stockpile Stewardship efforts and opening entirely new physical regimes to study. The technology developed for the Petawatt has also provided several spinoff technologies, including a new approach to laser material processing

  10. Faster magnet sorting with a threshold acceptance algorithm

    International Nuclear Information System (INIS)

    Lidia, S.; Carr, R.

    1995-01-01

    We introduce here a new technique for sorting magnets to minimize the field errors in permanent magnet insertion devices. Simulated annealing has been used in this role, but we find the technique of threshold acceptance produces results of equal quality in less computer time. Threshold accepting would be of special value in designing very long insertion devices, such as long free electron lasers (FELs). Our application of threshold acceptance to magnet sorting showed that it converged to equivalently low values of the cost function, but that it converged significantly faster. We present typical cases showing time to convergence for various error tolerances, magnet numbers, and temperature schedules

  11. Faster magnet sorting with a threshold acceptance algorithm

    International Nuclear Information System (INIS)

    Lidia, S.

    1994-08-01

    The authors introduce here a new technique for sorting magnets to minimize the field errors in permanent magnet insertion devices. Simulated annealing has been used in this role, but they find the technique of threshold acceptance produces results of equal quality in less computer time. Threshold accepting would be of special value in designing very long insertion devices, such as long FEL's. Their application of threshold acceptance to magnet sorting showed that it converged to equivalently low values of the cost function, but that it converged significantly faster. They present typical cases showing time to convergence for various error tolerances, magnet numbers, and temperature schedules

  12. Absolute chronology and stratigraphy of Lepenski Vir

    Directory of Open Access Journals (Sweden)

    Borić Dušan

    2007-01-01

    Full Text Available In the last decade, a number of specialist analyses were made on the material from old excavations of Mesolithic-Neolithic sites in the Danube Gorges. These new results altered significantly our understanding of the Lepenski Vir culture. The question of chronology of this regional phenomenon has been acute since the discovery of Lepenski Vir in the 1960s, and it remains of key importance for understanding the character of Mesolithic-Neolithic transformations in this and the neighbouring regions. The most heated debate was fuelled by the initial stratigraphic and chronological attribution of the type-site itself. There remained the question about the adequate dating of the most prominent phase at this site characterized by buildings with trapezoidal bases covered with limestone floors and with rectangular stone-lined hearths placed in the centre of these features. There have been suggestions that these features also contain Early Neolithic Starčevo type pottery and other similar items of material culture and should thus be dated to the Early Neolithic historical context. Moreover, the first series of conventional radiocarbon determinations (21 dates also suggested that the absolute chronology of these features should be confined to the period from around 6400-5500 cal BC (Fig. 1. Due to the importance of defining more precisely the chronology for the start of construction of these particular features at Lepenski Vir and for establishing the life-span of these buildings and their associated material culture, we have AMS (Accelerator Mass Spectrometry dated a number of contexts from this site. The results are presented in this paper. The project was made possible through the Oxford Radiocarbon Accelerate Dating Service (ORADS programme funded by the Arts and Humanities Research Council (AHRC and the Natural Environment Research Council (NERC of the Great Britain. Apart from those dates presented in this paper, there are 29 previously published

  13. The new Absolute Quantum Gravimeter (AQG): first results and perspectives

    Science.gov (United States)

    Bonvalot, Sylvain; Le Moigne, Nicolas; Merlet, Sebastien; Desruelle, Bruno; Lautier-Gaud, Jean; Menoret, Vincent; Vermeulen, Pierre

    2016-04-01

    Cold atom gravimetry represents one of the most innovative evolution in gravity instrumentation since the last 20 years. The concept of measuring the gravitational acceleration by dropping atoms and the development of the first instrumental devices during this last decade quickly revealed the promising perspectives of this new generation of gravity meters enabling accurate and absolute measurements of the Earth's gravity field for a wide range of applications (geophysics, geodesy, metrology, etc.). The Absolute Quantum Gravimeter (AQG) gravity meter, developed by MUQUANS (Talence, France - http://www.muquans.com/) with the support of RESIF, the French Seismologic and Geodetic Network (http://www.resif.fr/) belongs to this new generation of instruments. It also represents the first commercial device based on the utilization of advanced matter-wave interferometry techniques, which allow to characterize precisely the vertical acceleration experienced by a cloud of cold atoms. Recently, the first operational unit (AQG01) has been achieved as a compact transportable gravimeter with the aim of satisfying absolute gravity measurements in laboratory conditions under the following specifications: measurements the μGal level at a few Hz cycling frequency, sensitivity of 50μGal/√Hz, immunity to ground vibrations, easy and quickness of operation, automated continuous data acquisition for several months, etc. In order to evaluate the current performances of the AQG01, several experiments are carried out in collaboration between RESIF user's teams and the MUQUANS manufacturer on different reference gravity sites and laboratories in France. These measurements performed in indoor conditions including simultaneous observations with classical reference gravity instruments (corner-cube absolute gravity meters, relative superconducting meters) as well with the Cold Atom Gravity meter (CAG) developed by LNE-SYRTE, lead to a first objective characterization of the performances of

  14. Crossing the threshold

    Science.gov (United States)

    Bush, John; Tambasco, Lucas

    2017-11-01

    First, we summarize the circumstances in which chaotic pilot-wave dynamics gives rise to quantum-like statistical behavior. For ``closed'' systems, in which the droplet is confined to a finite domain either by boundaries or applied forces, quantum-like features arise when the persistence time of the waves exceeds the time required for the droplet to cross its domain. Second, motivated by the similarities between this hydrodynamic system and stochastic electrodynamics, we examine the behavior of a bouncing droplet above the Faraday threshold, where a stochastic element is introduced into the drop dynamics by virtue of its interaction with a background Faraday wave field. With a view to extending the dynamical range of pilot-wave systems to capture more quantum-like features, we consider a generalized theoretical framework for stochastic pilot-wave dynamics in which the relative magnitudes of the drop-generated pilot-wave field and a stochastic background field may be varied continuously. We gratefully acknowledge the financial support of the NSF through their CMMI and DMS divisions.

  15. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  16. Absolute-magnitude distributions of supernovae

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Dean; Wright, John [Department of Physics, Xavier University of Louisiana, New Orleans, LA 70125 (United States); Jenkins III, Robert L. [Applied Physics Department, Richard Stockton College, Galloway, NJ 08205 (United States); Maddox, Larry, E-mail: drichar7@xula.edu [Department of Chemistry and Physics, Southeastern Louisiana University, Hammond, LA 70402 (United States)

    2014-05-01

    The absolute-magnitude distributions of seven supernova (SN) types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M{sub B} < –21) make up only about 0.1% of all SNe in the bias-corrected sample. The subluminous events (M{sub B} > –15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of –19.25. The IIP distribution was the dimmest at –16.75.

  17. Absolute and relative dosimetry for ELIMED

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics Czech Academy of Science, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Leonora, E.; Randazzo, N. [INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Presti, D. Lo [INFN-Sezione di Catania, Via Santa Sofia 64, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Raffaele, L. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Tramontana, A. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Cirio, R.; Sacchi, R.; Monaco, V. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino, Italy and Università di Torino, Dipartimento di Fisica, Via P.Giuria, 1 10125 Torino (Italy); Marchetto, F.; Giordanengo, S. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino (Italy)

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  18. Fingerprints of flower absolutes using supercritical fluid chromatography hyphenated with high resolution mass spectrometry.

    Science.gov (United States)

    Santerre, Cyrille; Vallet, Nadine; Touboul, David

    2018-06-02

    Supercritical fluid chromatography hyphenated with high resolution mass spectrometry (SFC-HRMS) was developed for fingerprint analysis of different flower absolutes commonly used in cosmetics field, especially in perfumes. Supercritical fluid chromatography-atmospheric pressure photoionization-high resolution mass spectrometry (SFC-APPI-HRMS) technique was employed to identify the components of the fingerprint. The samples were separated with a porous graphitic carbon (PGC) Hypercarb™ column (100 mm × 2.1 mm, 3 μm) by gradient elution using supercritical CO 2 and ethanol (0.0-20.0 min (2-30% B), 20.0-25.0 min (30% B), 25.0-26.0 min (30-2% B) and 26.0-30.0 min (2% B)) as mobile phase at a flow rate of 1.5 mL/min. In order to compare the SFC fingerprints between five different flower absolutes: Jasminum grandiflorum absolutes, Jasminum sambac absolutes, Narcissus jonquilla absolutes, Narcissus poeticus absolutes, Lavandula angustifolia absolutes from different suppliers and batches, the chemometric procedure including principal component analysis (PCA) was applied to classify the samples according to their genus and their species. Consistent results were obtained to show that samples could be successfully discriminated. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Albania - Thresholds I and II

    Data.gov (United States)

    Millennium Challenge Corporation — From 2006 to 2011, the government of Albania (GOA) received two Millennium Challenge Corporation (MCC) Threshold Programs totaling $29.6 million. Albania received...

  20. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  1. Absolute purchasing power parity in industrial countries

    OpenAIRE

    Zhang, Zhibai; Bian, Zhicun

    2015-01-01

    Different from popular studies that focus on relative purchasing power parity, we study absolute purchasing power parity (APPP) in 21 main industrial countries. Three databases are used. Both the whole period and the sub-period are analyzed. The empirical proof shows that the phenomenon that APPP holds is common, and the phenomenon that APPP does not hold is also common. In addition, some country pairs and the pooled country data indicate that the nearer the GDPPs of two countries are, the mo...

  2. Internal descriptions of absolute Borel classes

    Czech Academy of Sciences Publication Activity Database

    Holický, P.; Pelant, Jan

    2004-01-01

    Roč. 141, č. 1 (2004), s. 87-104 ISSN 0166-8641 R&D Projects: GA ČR GA201/00/1466; GA ČR GA201/03/0933 Institutional research plan: CEZ:AV0Z1019905 Keywords : absolute Borel class * complete sequence of covers * open map Subject RIV: BA - General Mathematics Impact factor: 0.364, year: 2004

  3. The absolute differential calculus calculus of tensors

    CERN Document Server

    Levi-Cività, Tullio

    1926-01-01

    Written by a towering figure of twentieth-century mathematics, this classic examines the mathematical background necessary for a grasp of relativity theory. Tullio Levi-Civita provides a thorough treatment of the introductory theories that form the basis for discussions of fundamental quadratic forms and absolute differential calculus, and he further explores physical applications.Part one opens with considerations of functional determinants and matrices, advancing to systems of total differential equations, linear partial differential equations, algebraic foundations, and a geometrical intro

  4. An absolute deviation approach to assessing correlation.

    OpenAIRE

    Gorard, S.

    2015-01-01

    This paper describes two possible alternatives to the more traditional Pearson’s R correlation coefficient, both based on using the mean absolute deviation, rather than the standard deviation, as a measure of dispersion. Pearson’s R is well-established and has many advantages. However, these newer variants also have several advantages, including greater simplicity and ease of computation, and perhaps greater tolerance of underlying assumptions (such as the need for linearity). The first alter...

  5. Least Squares Problems with Absolute Quadratic Constraints

    Directory of Open Access Journals (Sweden)

    R. Schöne

    2012-01-01

    Full Text Available This paper analyzes linear least squares problems with absolute quadratic constraints. We develop a generalized theory following Bookstein's conic-fitting and Fitzgibbon's direct ellipse-specific fitting. Under simple preconditions, it can be shown that a minimum always exists and can be determined by a generalized eigenvalue problem. This problem is numerically reduced to an eigenvalue problem by multiplications of Givens' rotations. Finally, four applications of this approach are presented.

  6. Influence of pulse-height discrimination threshold for photon counting on the accuracy of singlet oxygen luminescence measurement

    International Nuclear Information System (INIS)

    Lin, Huiyun; Chen, Defu; Wang, Min; Lin, Juqiang; Li, Buhong; Xie, Shusen

    2011-01-01

    Direct measurement of near-infrared (NIR) luminescence around 1270 nm is the golden standard of singlet oxygen ( 1 O 2 ) identification. In this study, the influence of pulse-height discrimination threshold on measurement accuracy of the 1 O 2 luminescence that is generated from the photoirradiation of meso-tetra (N-methyl-4-pyridyl) morphine tetra-tosylate (TMPyP) in aqueous solution was investigated by using our custom-developed detection system. Our results indicate that the discrimination threshold has a significant influence on the absolute 1 O 2 luminescence counts, and the optimal threshold for our detection system is found to be about − 41.2 mV for signal discrimination. After optimization, the derived triplet-state and 1 O 2 lifetimes of TMPyP in aqueous solution are found to be 1.73 ± 0.03 and 3.70 ± 0.04 µs, respectively, and the accuracy of measurement was further independently demonstrated using the laser flash photolysis technique

  7. Absolute luminosity measurement at LHCb with beam-gas imaging

    CERN Document Server

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam-Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used *van der Meer scan* method (VDM). The technique has been used in 10 LHC fills during 2012 including and also provided a first luminosity measurement for proton-lead collisions. This talk presents the principles of the gas injection and the improvements reached with the increased pressure. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch. Those uncertainties are becoming the dominating factor because the uncertainty on the total beam current have been reduced.

  8. Effects of threshold displacement energy on defect production by displacement cascades in α, β and γ-LiAlO2

    International Nuclear Information System (INIS)

    Tsuchihira, H.; Oda, T.; Tanaka, S.

    2013-01-01

    Threshold displacement energy evaluation and a series of displacement cascade simulations in α, β, and γ-LiAlO 2 were performed using molecular dynamics. Threshold displacement energy evaluations indicated that higher absolute ionic charge values and larger densities both increase threshold displacement energy. The displacement cascade simulations suggest that the influence of different crystal structures on the number of interstitial atoms generated in a displacement cascade is explainable almost entirely by the difference of the threshold displacement energy

  9. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  10. Absolute emission cross sections for electron-impact excitation of Zn+(4p 2P) and (5s 2S) terms

    International Nuclear Information System (INIS)

    Rogers, W.T.; Dunn, G.H.; Olsen, J.O.; Reading, M.; Stefani, G.

    1982-01-01

    Absolute emission cross sections for electron-impact excitation of the 3d 10 4p 2 P and 3d 10 5s 2 S terms of Zn + have been measured from below threshold to about 790 eV 2 P and 390 eV 2 S using the crossed-charged-beams technique. Both transitions have the abrupt onset at threshold characteristic of positive-ion excitation. The 2 P cross section shows considerable structure in the interval from threshold to near 20 eV, above which it falls off smoothly. Agreement with five-state close-coupling theory is excellent below 100 eV when cascading is included in the theory. Above 100 eV, the data lie above the theory. The peak value of the 2 P cross section is 9.4 x 10 -16 cm 2 essentially at threshold, while the peak value of the 2 S cross section is about 0.47 x 10 -16 cm 2 . The net linear polarization of the 3d 10 4p 2 P emission was measured (unresolved from the 3d 10 4d 2 D→3d 10 4p 2 P cascading transition), and these data were used to correct the cross-section data for anisotropy of the emitted light. The effective lifetime of the 3d 9 4s 2 2 D/sub 3/2/ level was measured by observing exponential decay of the 589.6-nm photons resulting from its decay

  11. Effects of pulse duration on magnetostimulation thresholds

    Energy Technology Data Exchange (ETDEWEB)

    Saritas, Emine U., E-mail: saritas@ee.bilkent.edu.tr [Department of Bioengineering, University of California, Berkeley, Berkeley, California 94720-1762 (United States); Department of Electrical and Electronics Engineering, Bilkent University, Bilkent, Ankara 06800 (Turkey); National Magnetic Resonance Research Center (UMRAM), Bilkent University, Bilkent, Ankara 06800 (Turkey); Goodwill, Patrick W. [Department of Bioengineering, University of California, Berkeley, Berkeley, California 94720-1762 (United States); Conolly, Steven M. [Department of Bioengineering, University of California, Berkeley, Berkeley, California 94720-1762 (United States); Department of EECS, University of California, Berkeley, California 94720-1762 (United States)

    2015-06-15

    Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number of cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations

  12. Effects of pulse duration on magnetostimulation thresholds

    International Nuclear Information System (INIS)

    Saritas, Emine U.; Goodwill, Patrick W.; Conolly, Steven M.

    2015-01-01

    Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number of cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations

  13. Absolute magnitude estimation and relative judgement approaches to subjective workload assessment

    Science.gov (United States)

    Vidulich, Michael A.; Tsang, Pamela S.

    1987-01-01

    Two rating scale techniques employing an absolute magnitude estimation method, were compared to a relative judgment method for assessing subjective workload. One of the absolute estimation techniques used was an unidimensional overall workload scale and the other was the multidimensional NASA-Task Load Index technique. Thomas Saaty's Analytic Hierarchy Process was the unidimensional relative judgment method used. These techniques were used to assess the subjective workload of various single- and dual-tracking conditions. The validity of the techniques was defined as their ability to detect the same phenomena observed in the tracking performance. Reliability was assessed by calculating test-retest correlations. Within the context of the experiment, the Saaty Analytic Hierarchy Process was found to be superior in validity and reliability. These findings suggest that the relative judgment method would be an effective addition to the currently available subjective workload assessment techniques.

  14. Threshold Concepts and Information Literacy

    Science.gov (United States)

    Townsend, Lori; Brunetti, Korey; Hofer, Amy R.

    2011-01-01

    What do we teach when we teach information literacy in higher education? This paper describes a pedagogical approach to information literacy that helps instructors focus content around transformative learning thresholds. The threshold concept framework holds promise for librarians because it grounds the instructor in the big ideas and underlying…

  15. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  16. Thresholds for pulse wave velocity, urine albumin creatinine ratio and left ventricular mass index using SCORE, Framingham and ESH/ESC risk charts

    DEFF Research Database (Denmark)

    Sehestedt, Thomas Berend; Jeppesen, Jørgen; Hansen, Tine Willum

    2012-01-01

    Markers of subclinical target organ damage (TOD) increase cardiovascular (CV) risk prediction beyond traditional risk factors. We wanted to establish thresholds for three markers of TOD based on absolute CV risk in different risk chart categories....

  17. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  18. Absolute measurement of environmental radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1987-01-01

    A transportable meter for environmental radon measurement with a 40 liter decay chamber is designed on the principle of Thomas two-filter radon content absolute measurement. The sensitivity is 0.37 Bq·m -3 with 95% confidence level. This paper describes the experimental method of measuremment and it's intrinsic uncertainty. The typical intrinsic uncertainty (for n x 3.7 Bq·m -3 radon concentration) is <10%. The parameter of exit filter effeciency is introduced into the formula, and the verification is done for the case when the diameter of the exit filter is much less than the inlet one

  19. Fractional order absolute vibration suppression (AVS) controllers

    Science.gov (United States)

    Halevi, Yoram

    2017-04-01

    Absolute vibration suppression (AVS) is a control method for flexible structures. The first step is an accurate, infinite dimension, transfer function (TF), from actuation to measurement. This leads to the collocated, rate feedback AVS controller that in some cases completely eliminates the vibration. In case of the 1D wave equation, the TF consists of pure time delays and low order rational terms, and the AVS controller is rational. In all other cases, the TF and consequently the controller are fractional order in both the delays and the "rational parts". The paper considers stability, performance and actual implementation in such cases.

  20. The crack-initiation threshold in ceramic materials subject to elastic/plastic indentation

    International Nuclear Information System (INIS)

    Lankford, J.; Davidson, D.L.

    1979-01-01

    The threshold for indentation cracking is established for a range of ceramic materials, using the techniques of scanning electron microscopy and acoustic emission. It is found that by taking into account indentation plasticity, current theories may be successfully combined to predict threshold indentation loads and crack sizes. Threshold cracking is seen to relate to radial rather than median cracking. (author)

  1. Do multiple body modifications alter pain threshold?

    Science.gov (United States)

    Yamamotová, A; Hrabák, P; Hříbek, P; Rokyta, R

    2017-12-30

    In recent years, epidemiological data has shown an increasing number of young people who deliberately self-injure. There have also been parallel increases in the number of people with tattoos and those who voluntarily undergo painful procedures associated with piercing, scarification, and tattooing. People with self-injury behaviors often say that they do not feel the pain. However, there is no information regarding pain perception in those that visit tattoo parlors and piercing studios compared to those who don't. The aim of this study was to compare nociceptive sensitivity in four groups of subjects (n=105, mean age 26 years, 48 women and 57 men) with different motivations to experience pain (i.e., with and without multiple body modifications) in two different situations; (1) in controlled, emotionally neutral conditions, and (2) at a "Hell Party" (HP), an event organized by a piercing and tattoo parlor, with a main event featuring a public demonstration of painful techniques (burn scars, hanging on hooks, etc.). Pain thresholds of the fingers of the hand were measured using a thermal stimulator and mechanical algometer. In HP participants, information about alcohol intake, self-harming behavior, and psychiatric history were used in the analysis as intervening variables. Individuals with body modifications as well as without body modifications had higher thermal pain thresholds at Hell Party, compared to thresholds measured at control neutral conditions. No such differences were found relative to mechanical pain thresholds. Increased pain threshold in all HP participants, irrespectively of body modification, cannot be simply explained by a decrease in the sensory component of pain; instead, we found that the environment significantly influenced the cognitive and affective component of pain.

  2. ‘Soglitude’- introducing a method of thinking thresholds

    Directory of Open Access Journals (Sweden)

    Tatjana Barazon

    2010-04-01

    Full Text Available ‘Soglitude’ is an invitation to acknowledge the existence of thresholds in thought. A threshold in thought designates the indetermination, the passage, the evolution of every state the world is in. The creation we add to it, and the objectivity we suppose, on the border of those two ideas lies our perceptive threshold. No state will ever be permanent, and in order to stress the temporary, fluent character of the world and our perception of it, we want to introduce a new suitable method to think change and transformation, when we acknowledge our own threshold nature. The contributions gathered in this special issue come from various disciplines: anthropology, philosophy, critical theory, film studies, political science, literature and history. The variety of these insights shows the resonance of the idea of threshold in every category of thought. We hope to enlarge the notion in further issues on physics and chemistry, as well as mathematics. The articles in this issue introduce the method of threshold thinking by showing the importance of the in-between, of the changing of perspective in their respective domain. The ‘Documents’ section named INTERSTICES, includes a selection of poems, two essays, a philosophical-artistic project called ‘infraphysique’, a performance on thresholds in the soul, and a dialogue with Israel Rosenfield. This issue presents a kaleidoscope of possible threshold thinking and hopes to initiate new ways of looking at things.For every change that occurs in reality there is a subjective counterpart in our perception and this needs to be acknowledged as such. What we name objective is reflected in our own personal perception in its own personal manner, in such a way that the objectivity of an event might altogether be questioned. The absolute point of view, the view from “nowhere”, could well be the projection that causes dogmatism. By introducing the method of thinking thresholds into a system, be it

  3. Linear ultrasonic motor for absolute gravimeter.

    Science.gov (United States)

    Jian, Yue; Yao, Zhiyuan; Silberschmidt, Vadim V

    2017-05-01

    Thanks to their compactness and suitability for vacuum applications, linear ultrasonic motors are considered as substitutes for classical electromagnetic motors as driving elements in absolute gravimeters. Still, their application is prevented by relatively low power output. To overcome this limitation and provide better stability, a V-type linear ultrasonic motor with a new clamping method is proposed for a gravimeter. In this paper, a mechanical model of stators with flexible clamping components is suggested, according to a design criterion for clamps of linear ultrasonic motors. After that, an effect of tangential and normal rigidity of the clamping components on mechanical output is studied. It is followed by discussion of a new clamping method with sufficient tangential rigidity and a capability to facilitate pre-load. Additionally, a prototype of the motor with the proposed clamping method was fabricated and the performance tests in vertical direction were implemented. Experimental results show that the suggested motor has structural stability and high dynamic performance, such as no-load speed of 1.4m/s and maximal thrust of 43N, meeting the requirements for absolute gravimeters. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Relational versus absolute representation in categorization.

    Science.gov (United States)

    Edwards, Darren J; Pothos, Emmanuel M; Perlman, Amotz

    2012-01-01

    This study explores relational-like and absolute-like representations in categorization. Although there is much evidence that categorization processes can involve information about both the particular physical properties of studied instances and abstract (relational) properties, there has been little work on the factors that lead to one kind of representation as opposed to the other. We tested 370 participants in 6 experiments, in which participants had to classify new items into predefined artificial categories. In 4 experiments, we observed a predominantly relational-like mode of classification, and in 2 experiments we observed a shift toward an absolute-like mode of classification. These results suggest 3 factors that promote a relational-like mode of classification: fewer items per group, more training groups, and the presence of a time delay. Overall, we propose that less information about the distributional properties of a category or weaker memory traces for the category exemplars (induced, e.g., by having smaller categories or a time delay) can encourage relational-like categorization.

  5. On the absolute meaning of motion

    Directory of Open Access Journals (Sweden)

    H. Edwards

    Full Text Available The present manuscript aims to clarify why motion causes matter to age slower in a comparable sense, and how this relates to relativistic effects caused by motion. A fresh analysis of motion, build on first axiom, delivers proof with its result, from which significant new understanding and computational power is gained.A review of experimental results demonstrates, that unaccelerated motion causes matter to age slower in a comparable, observer independent sense. Whilst focusing on this absolute effect, the present manuscript clarifies its context to relativistic effects, detailing their relationship and incorporating both into one consistent picture. The presented theoretical results make new predictions and are testable through suggested experiment of a novel nature. The manuscript finally arrives at an experimental tool and methodology, which as far as motion in ungravitated space is concerned or gravity appreciated, enables us to find the absolute observer independent picture of reality, which is reflected in the comparable display of atomic clocks.The discussion of the theoretical results, derives a physical causal understanding of gravity, a mathematical formulation of which, will be presented. Keywords: Kinematics, Gravity, Atomic clocks, Cosmic microwave background

  6. Music effect on pain threshold evaluated with current perception threshold

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    AIM: Music relieves anxiety and psychotic tension. This effect of music is applied to surgical operation in the hospital and dental office. It is still unclear whether this music effect is only limited to the psychological aspect but not to the physical aspect or whether its music effect is influenced by the mood or emotion of audience. To elucidate these issues, we evaluated the music effect on pain threshold by current perception threshold (CPT) and profile of mood states (POMC) test. METHODS: Healthy 30 subjects (12 men, 18 women, 25-49 years old, mean age 34.9) were tested. (1)After POMC test, all subjects were evaluated pain threshold with CPT by Neurometer (Radionics, USA) under 6 conditions, silence, listening to the slow tempo classic music, nursery music, hard rock music, classic paino music and relaxation music with 30 seconds interval. (2)After Stroop color word test as the stresser, pain threshold was evaluated with CPT under 2 conditions, silence and listening to the slow tempo classic music. RESULTS: Under litening to the music, CPT sores increased, especially 2 000 Hz level related with compression, warm and pain sensation. Type of music, preference of music and stress also affected CPT score. CONCLUSION: The present study demonstrated that the concentration on the music raise the pain threshold and that stress and mood influence the music effect on pain threshold.

  7. Bound energy levels at the n=2 dissociation threshold in HD

    NARCIS (Netherlands)

    Pielage, T.G.P.; de Lange, A.; Brandi, F.; Ubachs, W.M.G.

    2002-01-01

    Level energies of g symmetry states lying just below the n = 2 dissociation threshold have been determined in a XUV + IR multi-step laser excitation experiment in HD, with an absolute accuracy of the excitation energy of 0.015 cm

  8. Relativistic Multichannel Treatment of Krypton Spectra across the First Ionization Threshold

    Institute of Scientific and Technical Information of China (English)

    QU Yi-Zhi; PENG Yong-Lun

    2005-01-01

    @@ The relativistic multichannel theory has been extended to calculate both the eigen quantum defects μα, transformation matrix Uiα, and the eigen dipole matrix elements Dα of krypton. The Rydberg and autoionizationspectra of krypton across the first ionization threshold are calculated within the framework of multichannel quantum defect theory. Our calculated spectra are in agreement with the absolute measurement data.

  9. Absolute determination of the deuterium content of heavy water, measurement of absolute density

    International Nuclear Information System (INIS)

    Ceccaldi, M.; Riedinger, M.; Menache, M.

    1975-01-01

    The absolute density of two heavy water samples rich in deuterium (with a grade higher than 99.9%) was determined with the hydrostatic method. The exact isotopic composition of this water (hydrogen and oxygen isotopes) was very carefully studied. A theoretical estimate enabled us to get the absolute density value of isotopically pure D 2 16 O. This value was found to be 1104.750 kg.m -3 at t 68 =22.3 0 C and under the pressure of one atmosphere. (orig.) [de

  10. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    Science.gov (United States)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  11. Image Segmentation using a Refined Comprehensive Learning Particle Swarm Optimizer for Maximum Tsallis Entropy Thresholding

    OpenAIRE

    L. Jubair Ahmed; A. Ebenezer Jeyakumar

    2013-01-01

    Thresholding is one of the most important techniques for performing image segmentation. In this paper to compute optimum thresholds for Maximum Tsallis entropy thresholding (MTET) model, a new hybrid algorithm is proposed by integrating the Comprehensive Learning Particle Swarm Optimizer (CPSO) with the Powell’s Conjugate Gradient (PCG) method. Here the CPSO will act as the main optimizer for searching the near-optimal thresholds while the PCG method will be used to fine tune the best solutio...

  12. Fuzzy Behavior Modulation with Threshold Activation for Autonomous Vehicle Navigation

    Science.gov (United States)

    Tunstel, Edward

    2000-01-01

    This paper describes fuzzy logic techniques used in a hierarchical behavior-based architecture for robot navigation. An architectural feature for threshold activation of fuzzy-behaviors is emphasized, which is potentially useful for tuning navigation performance in real world applications. The target application is autonomous local navigation of a small planetary rover. Threshold activation of low-level navigation behaviors is the primary focus. A preliminary assessment of its impact on local navigation performance is provided based on computer simulations.

  13. Absolute measurement of the critical scattering cross section in cobalt

    International Nuclear Information System (INIS)

    Glinka, C.J.; Minkiewicz, V.J.; Passell, L.

    1975-01-01

    Small-angle neutron scattering techniques have been used to study the angular distribution of the critical scattering from cobalt above T/sub c/. These measurements have been put on an absolute scale by calibrating the critical scattering directly against the nuclear incoherent scattering from cobalt. In this way the interaction range r 1 , which appears in the classical and modified Ornstein--Zernike expressions for the asymptotic form of the spin pair correlation function and is related to the strength of the spin correlations, has been determined. We obtain r 1 /a = 0.46 +- 0.03 for the ratio of the interaction range to the nearest-neighbor distance in cobalt. This result is in good agreement with theoretical predictions. Lack of agreement among previous determinations of the ratio r 1 /a made in iron failed to provide a definitive comparison with theory

  14. Absolute dimensions and masses of eclipsing binaries. V. IQ Persei

    International Nuclear Information System (INIS)

    Lacy, C.H.; Frueh, M.L.; McDonald Observatory, Austin)

    1985-01-01

    New photometric and spectroscopic observations of the 1.7 day eclipsing binary IQ Persei (B8 + A6) have been analyzed to yield very accurate fundamental properties of the system. Reticon spectroscopic observations obtained at McDonald Observatory were used to determine accurate radial velocities of both stars in this slightly eccentric large light-ratio binary. A new set of VR light curves obtained at McDonald Observatory were analyzed by synthesis techniques, and previously published UBV light curves were reanalyzed to yield accurate photometric orbits. Orbital parameters derived from both sets of photometric observations are in excellent agreement. The absolute dimensions, masses, luminosities, and apsidal motion period (140 yr) derived from these observations agree well with the predictions of theoretical stellar evolution models. The A6 secondary is still very close to the zero-age main sequence. The B8 primary is about one-third of the way through its main-sequence evolution. 27 references

  15. Parton distributions with threshold resummation

    CERN Document Server

    Bonvini, Marco; Rojo, Juan; Rottoli, Luca; Ubiali, Maria; Ball, Richard D.; Bertone, Valerio; Carrazza, Stefano; Hartland, Nathan P.

    2015-01-01

    We construct a set of parton distribution functions (PDFs) in which fixed-order NLO and NNLO calculations are supplemented with soft-gluon (threshold) resummation up to NLL and NNLL accuracy respectively, suitable for use in conjunction with any QCD calculation in which threshold resummation is included at the level of partonic cross sections. These resummed PDF sets, based on the NNPDF3.0 analysis, are extracted from deep-inelastic scattering, Drell-Yan, and top quark pair production data, for which resummed calculations can be consistently used. We find that, close to threshold, the inclusion of resummed PDFs can partially compensate the enhancement in resummed matrix elements, leading to resummed hadronic cross-sections closer to the fixed-order calculation. On the other hand, far from threshold, resummed PDFs reduce to their fixed-order counterparts. Our results demonstrate the need for a consistent use of resummed PDFs in resummed calculations.

  16. Invariant and Absolute Invariant Means of Double Sequences

    Directory of Open Access Journals (Sweden)

    Abdullah Alotaibi

    2012-01-01

    Full Text Available We examine some properties of the invariant mean, define the concepts of strong σ-convergence and absolute σ-convergence for double sequences, and determine the associated sublinear functionals. We also define the absolute invariant mean through which the space of absolutely σ-convergent double sequences is characterized.

  17. Conceptions of nuclear threshold status

    International Nuclear Information System (INIS)

    Quester, G.H.

    1991-01-01

    This paper reviews some alternative definitions of nuclear threshold status. Each of them is important, and major analytical confusions would result if one sense of the term is mistaken for another. The motives for nations entering into such threshold status are a blend of civilian and military gains, and of national interests versus parochial or bureaucratic interests. A portion of the rationale for threshold status emerges inevitably from the pursuit of economic goals, and another portion is made more attraction by the derives of the domestic political process. Yet the impact on international security cannot be dismissed, especially where conflicts among the states remain real. Among the military or national security motives are basic deterrence, psychological warfare, war-fighting and, more generally, national prestige. In the end, as the threshold phenomenon is assayed for lessons concerning the role of nuclear weapons more generally in international relations and security, one might conclude that threshold status and outright proliferation coverage to a degree in the motives for all of the states involved and in the advantages attained. As this paper has illustrated, nuclear threshold status is more subtle and more ambiguous than outright proliferation, and it takes considerable time to sort out the complexities. Yet the world has now had a substantial amount of time to deal with this ambiguous status, and this may tempt more states to exploit it

  18. Regional absolute conductivity reconstruction using projected current density in MREIT

    International Nuclear Information System (INIS)

    Sajib, Saurav Z K; Kim, Hyung Joong; Woo, Eung Je; Kwon, Oh In

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a non-invasive technique for imaging the internal conductivity distribution in tissue within an MRI scanner, utilizing the magnetic flux density, which is introduced when a current is injected into the tissue from external electrodes. This magnetic flux alters the MRI signal, so that appropriate reconstruction can provide a map of the additional z-component of the magnetic field (B z ) as well as the internal current density distribution that created it. To extract the internal electrical properties of the subject, including the conductivity and/or the current density distribution, MREIT techniques use the relationship between the external injection current and the z-component of the magnetic flux density B = (B x , B y , B z ). The tissue studied typically contains defective regions, regions with a low MRI signal and/or low MRI signal-to-noise-ratio, due to the low density of nuclear magnetic resonance spins, short T 2 or T* 2 relaxation times, as well as regions with very low electrical conductivity, through which very little current traverses. These defective regions provide noisy B z data, which can severely degrade the overall reconstructed conductivity distribution. Injecting two independent currents through surface electrodes, this paper proposes a new direct method to reconstruct a regional absolute isotropic conductivity distribution in a region of interest (ROI) while avoiding the defective regions. First, the proposed method reconstructs the contrast of conductivity using the transversal J-substitution algorithm, which blocks the propagation of severe accumulated noise from the defective region to the ROI. Second, the proposed method reconstructs the regional projected current density using the relationships between the internal current density, which stems from a current injection on the surface, and the measured B z data. Combining the contrast conductivity distribution in the entire imaging

  19. Improvements in absolute seismometer sensitivity calibration using local earth gravity measurements

    Science.gov (United States)

    Anthony, Robert E.; Ringler, Adam; Wilson, David

    2018-01-01

    The ability to determine both absolute and relative seismic amplitudes is fundamentally limited by the accuracy and precision with which scientists are able to calibrate seismometer sensitivities and characterize their response. Currently, across the Global Seismic Network (GSN), errors in midband sensitivity exceed 3% at the 95% confidence interval and are the least‐constrained response parameter in seismic recording systems. We explore a new methodology utilizing precise absolute Earth gravity measurements to determine the midband sensitivity of seismic instruments. We first determine the absolute sensitivity of Kinemetrics EpiSensor accelerometers to 0.06% at the 99% confidence interval by inverting them in a known gravity field at the Albuquerque Seismological Laboratory (ASL). After the accelerometer is calibrated, we install it in its normal configuration next to broadband seismometers and subject the sensors to identical ground motions to perform relative calibrations of the broadband sensors. Using this technique, we are able to determine the absolute midband sensitivity of the vertical components of Nanometrics Trillium Compact seismometers to within 0.11% and Streckeisen STS‐2 seismometers to within 0.14% at the 99% confidence interval. The technique enables absolute calibrations from first principles that are traceable to National Institute of Standards and Technology (NIST) measurements while providing nearly an order of magnitude more precision than step‐table calibrations.

  20. Absolute determination of 75Se for international comparison of activity measurements

    International Nuclear Information System (INIS)

    Iglicki, F.A.; Arenillas, P.A.; Furnari, J.C.

    1993-01-01

    An international intercomparison of absolute activity measurements of a solution of Se-75, organized by the Bureau International des Poids et Mesures, France, in 1992, has been carried out. The methodology and results are presented. Source preparation, experimental techniques and measurement system are described. (author). 2 refs

  1. Absolute measurement of the DT primary neutron yield on the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Leeper R.J.

    2013-11-01

    Full Text Available The measurement of the absolute neutron yield produced in inertial confinement fusion target experiments conducted on the National Ignition Facility (NIF is essential in benchmarking progress towards the goal of achieving ignition on this facility. This paper describes three independent diagnostic techniques that have been developed to make accurate and precise DT neutron yield measurements on the NIF.

  2. Absolute E0 and E2 transition rates and collective states in 116Sn

    International Nuclear Information System (INIS)

    Kantele, J.; Julin, R.; Luontama, M.; Passoja, A.; Poikolainen, T.; Baecklin, A.; Jonsson, N.-G.

    1978-08-01

    Absolute E0 and E2 transition rates in 116 Sn have been measured using several newly developed techniques. Many E2 transitions are observed to have a collective character with B(E2) values of up to 60 W.u. The presence of deformed excited states in 116 Sn is discussed in view of the results obtained. (author)

  3. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  4. Mosher Amides: Determining the Absolute Stereochemistry of Optically-Active Amines

    Science.gov (United States)

    Allen, Damian A.; Tomaso, Anthony E., Jr.; Priest, Owen P.; Hindson, David F.; Hurlburt, Jamie L.

    2008-01-01

    The use of chiral reagents for the derivatization of optically-active amines and alcohols for the purpose of determining their enantiomeric purity or absolute configuration is a tool used by many chemists. Among the techniques used, Mosher's amide and Mosher's ester analyses are among the most reliable and one of the most often used. Despite this,…

  5. How is an absolute democracy possible?

    Directory of Open Access Journals (Sweden)

    Joanna Bednarek

    2011-01-01

    Full Text Available In the last part of the Empire trilogy, Commonwealth, Negri and Hardt ask about the possibility of the self-governance of the multitude. When answering, they argue that absolute democracy, understood as the political articulation of the multitude that does not entail its unification (construction of the people is possible. As Negri states, this way of thinking about political articulation is rooted in the tradition of democratic materialism and constitutes the alternative to the dominant current of modern political philosophy that identifies political power with sovereignty. The multitude organizes itself politically by means of the constitutive power, identical with the ontological creativity or productivity of the multitude. To state the problem of political organization means to state the problem of class composition: political democracy is at the same time economic democracy.

  6. Absolute partial photoionization cross sections of ethylene

    Science.gov (United States)

    Grimm, F. A.; Whitley, T. A.; Keller, P. R.; Taylor, J. W.

    1991-07-01

    Absolute partial photoionization cross sections for ionization out of the first four valence orbitals to the X 2B 3u, A 2B 3g, B 2A g and C 2B 2u states of the C 2H 4+ ion are presented as a function of photon energy over the energy range from 12 to 26 eV. The experimental results have been compared to previously published relative partial cross sections for the first two bands at 18, 21 and 24 eV. Comparison of the experimental data with continuum multiple scattering Xα calculations provides evidence for extensive autoionization to the X 2B 3u state and confirms the predicted shape resonances in ionization to the A 2B 3g and B 2A g states. Identification of possible transitions for the autoionizing resonances have been made using multiple scattering transition state calculations on Rydberg excited states.

  7. Absolute beam current monitoring in endstation c

    International Nuclear Information System (INIS)

    Bochna, C.

    1995-01-01

    The first few experiments at CEBAF require approximately 1% absolute measurements of beam currents expected to range from 10-25μA. This represents errors of 100-250 nA. The initial complement of beam current monitors are of the non intercepting type. CEBAF accelerator division has provided a stripline monitor and a cavity monitor, and the authors have installed an Unser monitor (parametric current transformer or PCT). After calibrating the Unser monitor with a precision current reference, the authors plan to transfer this calibration using CW beam to the stripline monitors and cavity monitors. It is important that this be done fairly rapidly because while the gain of the Unser monitor is quite stable, the offset may drift on the order of .5μA per hour. A summary of what the authors have learned about the linearity, zero drift, and gain drift of each type of current monitor will be presented

  8. Absolute negative mobility in the anomalous diffusion

    Science.gov (United States)

    Chen, Ruyin; Chen, Chongyang; Nie, Linru

    2017-12-01

    Transport of an inertial Brownian particle driven by the multiplicative Lévy noise was investigated here. Numerical results indicate that: (i) The Lévy noise is able to induce absolute negative mobility (ANM) in the system, while disappearing in the deterministic case; (ii) the ANM can occur in the region of superdiffusion while disappearing in the region of normal diffusion, and the appropriate stable index of the Lévy noise makes the particle move along the opposite direction of the bias force to the maximum degree; (iii) symmetry breaking of the Lévy noise also causes the ANM effect. In addition, the intrinsic physical mechanism and conditions for the ANM to occur are discussed in detail. Our results have the implication that the Lévy noise plays an important role in the occurrence of the ANM phenomenon.

  9. Absolute GPS Positioning Using Genetic Algorithms

    Science.gov (United States)

    Ramillien, G.

    A new inverse approach for restoring the absolute coordinates of a ground -based station from three or four observed GPS pseudo-ranges is proposed. This stochastic method is based on simulations of natural evolution named genetic algorithms (GA). These iterative procedures provide fairly good and robust estimates of the absolute positions in the Earth's geocentric reference system. For comparison/validation, GA results are compared to the ones obtained using the classical linearized least-square scheme for the determination of the XYZ location proposed by Bancroft (1985) which is strongly limited by the number of available observations (i.e. here, the number of input pseudo-ranges must be four). The r.m.s. accuracy of the non -linear cost function reached by this latter method is typically ~10-4 m2 corresponding to ~300-500-m accuracies for each geocentric coordinate. However, GA can provide more acceptable solutions (r.m.s. errors < 10-5 m2), even when only three instantaneous pseudo-ranges are used, such as a lost of lock during a GPS survey. Tuned GA parameters used in different simulations are N=1000 starting individuals, as well as Pc=60-70% and Pm=30-40% for the crossover probability and mutation rate, respectively. Statistical tests on the ability of GA to recover acceptable coordinates in presence of important levels of noise are made simulating nearly 3000 random samples of erroneous pseudo-ranges. Here, two main sources of measurement errors are considered in the inversion: (1) typical satellite-clock errors and/or 300-metre variance atmospheric delays, and (2) Geometrical Dilution of Precision (GDOP) due to the particular GPS satellite configuration at the time of acquisition. Extracting valuable information and even from low-quality starting range observations, GA offer an interesting alternative for high -precision GPS positioning.

  10. Variance computations for functional of absolute risk estimates.

    Science.gov (United States)

    Pfeiffer, R M; Petracci, E

    2011-07-01

    We present a simple influence function based approach to compute the variances of estimates of absolute risk and functions of absolute risk. We apply this approach to criteria that assess the impact of changes in the risk factor distribution on absolute risk for an individual and at the population level. As an illustration we use an absolute risk prediction model for breast cancer that includes modifiable risk factors in addition to standard breast cancer risk factors. Influence function based variance estimates for absolute risk and the criteria are compared to bootstrap variance estimates.

  11. Assignment of absolute stereostructures through quantum mechanics electronic and vibrational circular dichroism calculations.

    Science.gov (United States)

    Dai, Peng; Jiang, Nan; Tan, Ren-Xiang

    2016-01-01

    Elucidation of absolute configuration of chiral molecules including structurally complex natural products remains a challenging problem in organic chemistry. A reliable method for assigning the absolute stereostructure is to combine the experimental circular dichroism (CD) techniques such as electronic and vibrational CD (ECD and VCD), with quantum mechanics (QM) ECD and VCD calculations. The traditional QM methods as well as their continuing developments make them more applicable with accuracy. Taking some chiral natural products with diverse conformations as examples, this review describes the basic concepts and new developments of QM approaches for ECD and VCD calculations in solution and solid states.

  12. Absolute photoionization cross-section measurements of the Kr I isoelectronic sequence

    International Nuclear Information System (INIS)

    Kilbane, D.; Banahan, C.; Kampen, P. van; Costello, J. T.; Folkmann, F.; Kjeldsen, H.; Bizau, J.-M.; Scully, S.; Mansfield, M. W. D.; West, J. B.

    2007-01-01

    Photoionization spectra have been recorded in the 4s, 4p, and 3d resonance regions for the Kr I isoelectronic sequence using both the dual laser produced plasma (DLP) technique (at DCU) to produce photoabsorption spectra, and the merged ion beam and synchrotron radiation technique (at ASTRID) to measure absolute photoionization cross sections. Profile parameters are compared for the 4s-np resonances of Rb + and Sr 2+ . Many 4p→ns, md transitions are identified with the aid of Hartree-Fock calculations, and consistent quantum defects are observed for the various ns and md Rydberg series. Absolute single and double photoionization cross sections recorded in the 3d region for Rb + and Sr 2+ ions show preferential decay via double photoionization. This is only the second report to our knowledge where both the DLP technique and the merged-beam technique have been used simultaneously to record photoionization spectra, and the advantages of both techniques (i.e., better resolution in the case of DLP and values for absolute photoionization cross sections in the case of the merged-beam technique) are highlighted

  13. Doubler system quench detection threshold

    International Nuclear Information System (INIS)

    Kuepke, K.; Kuchnir, M.; Martin, P.

    1983-01-01

    The experimental study leading to the determination of the sensitivity needed for protecting the Fermilab Doubler from damage during quenches is presented. The quench voltage thresholds involved were obtained from measurements made on Doubler cable of resistance x temperature and voltage x time during quenches under several currents and from data collected during operation of the Doubler Quench Protection System as implemented in the B-12 string of 20 magnets. At 4kA, a quench voltage threshold in excess of 5.OV will limit the peak Doubler cable temperature to 452K for quenches originating in the magnet coils whereas a threshold of 0.5V is required for quenches originating outside of coils

  14. Thermotactile perception thresholds measurement conditions.

    Science.gov (United States)

    Maeda, Setsuo; Sakakibara, Hisataka

    2002-10-01

    The purpose of this paper is to investigate the effects of posture, push force and rate of temperature change on thermotactile thresholds and to clarify suitable measuring conditions for Japanese people. Thermotactile (warm and cold) thresholds on the right middle finger were measured with an HVLab thermal aesthesiometer. Subjects were eight healthy male Japanese students. The effects of posture in measurement were examined in the posture of a straight hand and forearm placed on a support, the same posture without a support, and the fingers and hand flexed at the wrist with the elbow placed on a desk. The finger push force applied to the applicator of the thermal aesthesiometer was controlled at a 0.5, 1.0, 2.0 and 3.0 N. The applicator temperature was changed to 0.5, 1.0, 1.5, 2.0 and 2.5 degrees C/s. After each measurement, subjects were asked about comfort under the measuring conditions. Three series of experiments were conducted on different days to evaluate repeatability. Repeated measures ANOVA showed that warm thresholds were affected by the push force and the rate of temperature change and that cold thresholds were influenced by posture and push force. The comfort assessment indicated that the measurement posture of a straight hand and forearm laid on a support was the most comfortable for the subjects. Relatively high repeatability was obtained under measurement conditions of a 1 degrees C/s temperature change rate and a 0.5 N push force. Measurement posture, push force and rate of temperature change can affect the thermal threshold. Judging from the repeatability, a push force of 0.5 N and a temperature change of 1.0 degrees C/s in the posture with the straight hand and forearm laid on a support are recommended for warm and cold threshold measurements.

  15. DOE approach to threshold quantities

    International Nuclear Information System (INIS)

    Wickham, L.E.; Kluk, A.F.; Department of Energy, Washington, DC)

    1985-01-01

    The Department of Energy (DOE) is developing the concept of threshold quantities for use in determining which waste materials must be handled as radioactive waste and which may be disposed of as nonradioactive waste at its sites. Waste above this concentration level would be managed as radioactive or mixed waste (if hazardous chemicals are present); waste below this level would be handled as sanitary waste. Ideally, the threshold must be set high enough to significantly reduce the amount of waste requiring special handling. It must also be low enough so that waste at the threshold quantity poses a very small health risk and multiple exposures to such waste would still constitute a small health risk. It should also be practical to segregate waste above or below the threshold quantity using available instrumentation. Guidance is being prepared to aid DOE sites in establishing threshold quantity values based on pathways analysis using site-specific parameters (waste stream characteristics, maximum exposed individual, population considerations, and site specific parameters such as rainfall, etc.). A guidance dose of between 0.001 to 1.0 mSv/y (0.1 to 100 mrem/y) was recommended with 0.3 mSv/y (30 mrem/y) selected as the guidance dose upon which to base calculations. Several tasks were identified, beginning with the selection of a suitable pathway model for relating dose to the concentration of radioactivity in the waste. Threshold concentrations corresponding to the guidance dose were determined for waste disposal sites at a selected humid and arid site. Finally, cost-benefit considerations at the example sites were addressed. The results of the various tasks are summarized and the relationship of this effort with related developments at other agencies discussed

  16. A threshold for dissipative fission

    International Nuclear Information System (INIS)

    Thoennessen, M.; Bertsch, G.F.

    1993-01-01

    The empirical domain of validity of statistical theory is examined as applied to fission data on pre-fission data on pre-fission neutron, charged particle, and γ-ray multiplicities. Systematics are found of the threshold excitation energy for the appearance of nonstatistical fission. From the data on systems with not too high fissility, the relevant phenomenological parameter is the ratio of the threshold temperature T thresh to the (temperature-dependent) fission barrier height E Bar (T). The statistical model reproduces the data for T thresh /E Bar (T) thresh /E Bar (T) independent of mass and fissility of the systems

  17. Thresholds in chemical respiratory sensitisation.

    Science.gov (United States)

    Cochrane, Stella A; Arts, Josje H E; Ehnes, Colin; Hindle, Stuart; Hollnagel, Heli M; Poole, Alan; Suto, Hidenori; Kimber, Ian

    2015-07-03

    There is a continuing interest in determining whether it is possible to identify thresholds for chemical allergy. Here allergic sensitisation of the respiratory tract by chemicals is considered in this context. This is an important occupational health problem, being associated with rhinitis and asthma, and in addition provides toxicologists and risk assessors with a number of challenges. In common with all forms of allergic disease chemical respiratory allergy develops in two phases. In the first (induction) phase exposure to a chemical allergen (by an appropriate route of exposure) causes immunological priming and sensitisation of the respiratory tract. The second (elicitation) phase is triggered if a sensitised subject is exposed subsequently to the same chemical allergen via inhalation. A secondary immune response will be provoked in the respiratory tract resulting in inflammation and the signs and symptoms of a respiratory hypersensitivity reaction. In this article attention has focused on the identification of threshold values during the acquisition of sensitisation. Current mechanistic understanding of allergy is such that it can be assumed that the development of sensitisation (and also the elicitation of an allergic reaction) is a threshold phenomenon; there will be levels of exposure below which sensitisation will not be acquired. That is, all immune responses, including allergic sensitisation, have threshold requirement for the availability of antigen/allergen, below which a response will fail to develop. The issue addressed here is whether there are methods available or clinical/epidemiological data that permit the identification of such thresholds. This document reviews briefly relevant human studies of occupational asthma, and experimental models that have been developed (or are being developed) for the identification and characterisation of chemical respiratory allergens. The main conclusion drawn is that although there is evidence that the

  18. Optimization Problems on Threshold Graphs

    Directory of Open Access Journals (Sweden)

    Elena Nechita

    2010-06-01

    Full Text Available During the last three decades, different types of decompositions have been processed in the field of graph theory. Among these we mention: decompositions based on the additivity of some characteristics of the graph, decompositions where the adjacency law between the subsets of the partition is known, decompositions where the subgraph induced by every subset of the partition must have predeterminate properties, as well as combinations of such decompositions. In this paper we characterize threshold graphs using the weakly decomposition, determine: density and stability number, Wiener index and Wiener polynomial for threshold graphs.

  19. Threshold current for fireball generation

    Science.gov (United States)

    Dijkhuis, Geert C.

    1982-05-01

    Fireball generation from a high-intensity circuit breaker arc is interpreted here as a quantum-mechanical phenomenon caused by severe cooling of electrode material evaporating from contact surfaces. According to the proposed mechanism, quantum effects appear in the arc plasma when the radius of one magnetic flux quantum inside solid electrode material has shrunk to one London penetration length. A formula derived for the threshold discharge current preceding fireball generation is found compatible with data reported by Silberg. This formula predicts linear scaling of the threshold current with the circuit breaker's electrode radius and concentration of conduction electrons.

  20. Absolute Lower Bound on the Bounce Action

    Science.gov (United States)

    Sato, Ryosuke; Takimoto, Masahiro

    2018-03-01

    The decay rate of a false vacuum is determined by the minimal action solution of the tunneling field: bounce. In this Letter, we focus on models with scalar fields which have a canonical kinetic term in N (>2 ) dimensional Euclidean space, and derive an absolute lower bound on the bounce action. In the case of four-dimensional space, we show the bounce action is generically larger than 24 /λcr, where λcr≡max [-4 V (ϕ )/|ϕ |4] with the false vacuum being at ϕ =0 and V (0 )=0 . We derive this bound on the bounce action without solving the equation of motion explicitly. Our bound is derived by a quite simple discussion, and it provides useful information even if it is difficult to obtain the explicit form of the bounce solution. Our bound offers a sufficient condition for the stability of a false vacuum, and it is useful as a quick check on the vacuum stability for given models. Our bound can be applied to a broad class of scalar potential with any number of scalar fields. We also discuss a necessary condition for the bounce action taking a value close to this lower bound.

  1. Gyrokinetic statistical absolute equilibrium and turbulence

    International Nuclear Information System (INIS)

    Zhu Jianzhou; Hammett, Gregory W.

    2010-01-01

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: a finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N+1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  2. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    International Nuclear Information System (INIS)

    Zhu, Jian-Zhou; Hammett, Gregory W.

    2011-01-01

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence (T.-D. Lee, 'On some statistical properties of hydrodynamical and magnetohydrodynamical fields,' Q. Appl. Math. 10, 69 (1952)) is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  3. [Tobacco and plastic surgery: An absolute contraindication?

    Science.gov (United States)

    Matusiak, C; De Runz, A; Maschino, H; Brix, M; Simon, E; Claudot, F

    2017-08-01

    Smoking increases perioperative risk regarding wound healing, infection rate and failure of microsurgical procedures. There is no present consensus about plastic and aesthetic surgical indications concerning smoking patients. The aim of our study is to analyze French plastic surgeons practices concerning smokers. A questionnaire was send by e-mail to French plastic surgeons in order to evaluate their own operative indications: patient information about smoking dangers, pre- and postoperative delay of smoking cessation, type of intervention carried out, smoking cessation supports, use of screening test and smoking limit associated to surgery refusing were studied. Statistical tests were used to compare results according to practitioner activity (liberal or public), own smoking habits and time of installation. In 148 questionnaires, only one surgeon did not explain smoking risk. Of the surgeons, 49.3% proposed smoking-cessation supports, more frequently with public practice (P=0.019). In total, 85.4% of surgeons did not use screening tests. Years of installation affected operative indication with smoking patients (P=0.02). Pre- and postoperative smoking cessation delay were on average respectively 4 and 3 weeks in accordance with literature. Potential improvements could be proposed to smoking patients' care: smoking cessation assistance, screening tests, absolute contraindication of some procedures or level of consumption to determine. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Nuclear threshold effects and neutron strength function

    International Nuclear Information System (INIS)

    Hategan, Cornel; Comisel, Horia

    2003-01-01

    One proves that a Nuclear Threshold Effect is dependent, via Neutron Strength Function, on Spectroscopy of Ancestral Neutron Threshold State. The magnitude of the Nuclear Threshold Effect is proportional to the Neutron Strength Function. Evidence for relation of Nuclear Threshold Effects to Neutron Strength Functions is obtained from Isotopic Threshold Effect and Deuteron Stripping Threshold Anomaly. The empirical and computational analysis of the Isotopic Threshold Effect and of the Deuteron Stripping Threshold Anomaly demonstrate their close relationship to Neutron Strength Functions. It was established that the Nuclear Threshold Effects depend, in addition to genuine Nuclear Reaction Mechanisms, on Spectroscopy of (Ancestral) Neutron Threshold State. The magnitude of the effect is proportional to the Neutron Strength Function, in their dependence on mass number. This result constitutes also a proof that the origins of these threshold effects are Neutron Single Particle States at zero energy. (author)

  5. Quantitative blood flow analysis with digital techniques

    International Nuclear Information System (INIS)

    Forbes, G.

    1984-01-01

    The general principles of digital techniques in quantitating absolute blood flow during arteriography are described. Results are presented for a phantom constructed to correlate digitally calculated absolute flow with direct flow measurements. The clinical use of digital techniques in cerebrovascular angiography is briefly described. (U.K.)

  6. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    Science.gov (United States)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  7. Compressively sampled MR image reconstruction using generalized thresholding iterative algorithm

    Science.gov (United States)

    Elahi, Sana; kaleem, Muhammad; Omer, Hammad

    2018-01-01

    Compressed sensing (CS) is an emerging area of interest in Magnetic Resonance Imaging (MRI). CS is used for the reconstruction of the images from a very limited number of samples in k-space. This significantly reduces the MRI data acquisition time. One important requirement for signal recovery in CS is the use of an appropriate non-linear reconstruction algorithm. It is a challenging task to choose a reconstruction algorithm that would accurately reconstruct the MR images from the under-sampled k-space data. Various algorithms have been used to solve the system of non-linear equations for better image quality and reconstruction speed in CS. In the recent past, iterative soft thresholding algorithm (ISTA) has been introduced in CS-MRI. This algorithm directly cancels the incoherent artifacts produced because of the undersampling in k -space. This paper introduces an improved iterative algorithm based on p -thresholding technique for CS-MRI image reconstruction. The use of p -thresholding function promotes sparsity in the image which is a key factor for CS based image reconstruction. The p -thresholding based iterative algorithm is a modification of ISTA, and minimizes non-convex functions. It has been shown that the proposed p -thresholding iterative algorithm can be used effectively to recover fully sampled image from the under-sampled data in MRI. The performance of the proposed method is verified using simulated and actual MRI data taken at St. Mary's Hospital, London. The quality of the reconstructed images is measured in terms of peak signal-to-noise ratio (PSNR), artifact power (AP), and structural similarity index measure (SSIM). The proposed approach shows improved performance when compared to other iterative algorithms based on log thresholding, soft thresholding and hard thresholding techniques at different reduction factors.

  8. 16O resonances near the 4α threshold through the 12C(6Li,d) reaction

    Science.gov (United States)

    Rodrigues, M. R. D.; Borello-Lewin, T.; Miyake, H.; Duarte, J. L. M.; Rodrigues, C. L.; Souza, M. A.; Horodynski-Matsushigue, L. B.; Ukita, G. M.; Cappuzzello, F.; Cunsolo, A.; Cavallaro, M.; Agodi, C.; Foti, A.

    2014-02-01

    Background: Resonances around xα thresholds in light nuclei are recognized to be important in basic aspects of nuclear structure. However, there is scarce experimental information associated with them. Purpose: We study the α-clustering phenomenon in resonant states around the 4α threshold (14.44 MeV) in the 16O nucleus. Method: The 12C(6Li,d )16O reaction was investigated with an unprecedented resolution at a bombarding energy of 25.5 MeV by employing the São Paulo Pelletron-Enge-Spectrograph facility and the nuclear emulsion technique. Results: Several narrow resonances were populated and the energy resolution of 15 keV allows for the separation of doublet states that were not resolved previously. The upper limits for the resonance widths in this region were extracted. The angular distributions of the absolute differential cross section associated with four natural parity quasibound states are presented and compared to distorted wave Born approximation predictions. Conclusions: Narrow resonances not previously reported in the literature were observed. This indicates that the α-cluster structure information in this region should be revised.

  9. Percolation Threshold Parameters of Fluids

    Czech Academy of Sciences Publication Activity Database

    Škvor, J.; Nezbeda, Ivo

    2009-01-01

    Roč. 79, č. 4 (2009), 041141-041147 ISSN 1539-3755 Institutional research plan: CEZ:AV0Z40720504 Keywords : percolation threshold * universality * infinite cluster Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.400, year: 2009

  10. Threshold analyses and Lorentz violation

    International Nuclear Information System (INIS)

    Lehnert, Ralf

    2003-01-01

    In the context of threshold investigations of Lorentz violation, we discuss the fundamental principle of coordinate independence, the role of an effective dynamical framework, and the conditions of positivity and causality. Our analysis excludes a variety of previously considered Lorentz-breaking parameters and opens an avenue for viable dispersion-relation investigations of Lorentz violation

  11. Threshold enhancement of diphoton resonances

    Directory of Open Access Journals (Sweden)

    Aoife Bharucha

    2016-10-01

    Full Text Available We revisit a mechanism to enhance the decay width of (pseudo-scalar resonances to photon pairs when the process is mediated by loops of charged fermions produced near threshold. Motivated by the recent LHC data, indicating the presence of an excess in the diphoton spectrum at approximately 750 GeV, we illustrate this threshold enhancement mechanism in the case of a 750 GeV pseudoscalar boson A with a two-photon decay mediated by a charged and uncolored fermion having a mass at the 12MA threshold and a small decay width, <1 MeV. The implications of such a threshold enhancement are discussed in two explicit scenarios: i the Minimal Supersymmetric Standard Model in which the A state is produced via the top quark mediated gluon fusion process and decays into photons predominantly through loops of charginos with masses close to 12MA and ii a two Higgs doublet model in which A is again produced by gluon fusion but decays into photons through loops of vector-like charged heavy leptons. In both these scenarios, while the mass of the charged fermion has to be adjusted to be extremely close to half of the A resonance mass, the small total widths are naturally obtained if only suppressed three-body decay channels occur. Finally, the implications of some of these scenarios for dark matter are discussed.

  12. Limitations of threshold voltage engineering of AlGaN/GaN heterostructures by dielectric interface charge density and manipulation by oxygen plasma surface treatments

    Science.gov (United States)

    Lükens, G.; Yacoub, H.; Kalisch, H.; Vescan, A.

    2016-05-01

    The interface charge density between the gate dielectric and an AlGaN/GaN heterostructure has a significant impact on the absolute value and stability of the threshold voltage Vth of metal-insulator-semiconductor (MIS) heterostructure field effect transistor. It is shown that a dry-etching step (as typically necessary for normally off devices engineered by gate-recessing) before the Al2O3 gate dielectric deposition introduces a high positive interface charge density. Its origin is most likely donor-type trap states shifting Vth to large negative values, which is detrimental for normally off devices. We investigate the influence of oxygen plasma annealing techniques of the dry-etched AlGaN/GaN surface by capacitance-voltage measurements and demonstrate that the positive interface charge density can be effectively compensated. Furthermore, only a low Vth hysteresis is observable making this approach suitable for threshold voltage engineering. Analysis of the electrostatics in the investigated MIS structures reveals that the maximum Vth shift to positive voltages achievable is fundamentally limited by the onset of accumulation of holes at the dielectric/barrier interface. In the case of the Al2O3/Al0.26Ga0.74N/GaN material system, this maximum threshold voltage shift is limited to 2.3 V.

  13. Evaluation of the absolute regional temperature potential

    Directory of Open Access Journals (Sweden)

    D. T. Shindell

    2012-09-01

    Full Text Available The Absolute Regional Temperature Potential (ARTP is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90–28° S, 28° S–28° N, 28–60° N and 60–90° N as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within ±20% of the actual responses, though there are some exceptions for 90–28° S and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the ±20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39–45% and 9–39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  14. Planck absolute entropy of a rotating BTZ black hole

    Science.gov (United States)

    Riaz, S. M. Jawwad

    2018-04-01

    In this paper, the Planck absolute entropy and the Bekenstein-Smarr formula of the rotating Banados-Teitelboim-Zanelli (BTZ) black hole are presented via a complex thermodynamical system contributed by its inner and outer horizons. The redefined entropy approaches zero as the temperature of the rotating BTZ black hole tends to absolute zero, satisfying the Nernst formulation of a black hole. Hence, it can be regarded as the Planck absolute entropy of the rotating BTZ black hole.

  15. Positioning, alignment and absolute pointing of the ANTARES neutrino telescope

    International Nuclear Information System (INIS)

    Fehr, F; Distefano, C

    2010-01-01

    A precise detector alignment and absolute pointing is crucial for point-source searches. The ANTARES neutrino telescope utilises an array of hydrophones, tiltmeters and compasses for the relative positioning of the optical sensors. The absolute calibration is accomplished by long-baseline low-frequency triangulation of the acoustic reference devices in the deep-sea with a differential GPS system at the sea surface. The absolute pointing can be independently verified by detecting the shadow of the Moon in cosmic rays.

  16. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  17. Thresher: an improved algorithm for peak height thresholding of microbial community profiles.

    Science.gov (United States)

    Starke, Verena; Steele, Andrew

    2014-11-15

    This article presents Thresher, an improved technique for finding peak height thresholds for automated rRNA intergenic spacer analysis (ARISA) profiles. We argue that thresholds must be sample dependent, taking community richness into account. In most previous fragment analyses, a common threshold is applied to all samples simultaneously, ignoring richness variations among samples and thereby compromising cross-sample comparison. Our technique solves this problem, and at the same time provides a robust method for outlier rejection, selecting for removal any replicate pairs that are not valid replicates. Thresholds are calculated individually for each replicate in a pair, and separately for each sample. The thresholds are selected to be the ones that minimize the dissimilarity between the replicates after thresholding. If a choice of threshold results in the two replicates in a pair failing a quantitative test of similarity, either that threshold or that sample must be rejected. We compare thresholded ARISA results with sequencing results, and demonstrate that the Thresher algorithm outperforms conventional thresholding techniques. The software is implemented in R, and the code is available at http://verenastarke.wordpress.com or by contacting the author. vstarke@ciw.edu or http://verenastarke.wordpress.com Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Time Poverty Thresholds and Rates for the US Population

    Science.gov (United States)

    Kalenkoski, Charlene M.; Hamrick, Karen S.; Andrews, Margaret

    2011-01-01

    Time constraints, like money constraints, affect Americans' well-being. This paper defines what it means to be time poor based on the concepts of necessary and committed time and presents time poverty thresholds and rates for the US population and certain subgroups. Multivariate regression techniques are used to identify the key variables…

  19. Metastability Thresholds for Anisotropic Bootstrap Percolation in Three Dimensions

    NARCIS (Netherlands)

    Enter, Aernout C.D. van; Fey, Anne

    In this paper we analyze several anisotropic bootstrap percolation models in three dimensions. We present the order of magnitude for the metastability thresholds for a fairly general class of models. In our proofs, we use an adaptation of the technique of dimensional reduction. We find that the

  20. The issue of threshold states

    International Nuclear Information System (INIS)

    Luck, L.

    1994-01-01

    The states which have not joined the Non-proliferation Treaty nor have undertaken any other internationally binding commitment not to develop or otherwise acquire nuclear weapons are considered a threshold states. Their nuclear status is rendered opaque as a conscious policy. Nuclear threshold status remains a key disarmament issue. For those few states, as India, Pakistan, Israel, who have put themselves in this position, the security returns have been transitory and largely illusory. The cost to them, and to the international community committed to the norm of non-proliferation, has been huge. The decisions which could lead to recovery from the situation in which they find themselves are essentially at their own hands. Whatever assistance the rest of international community is able to extend, it will need to be accompanied by a vital political signal

  1. Multiscalar production amplitudes beyond threshold

    CERN Document Server

    Argyres, E N; Kleiss, R H

    1993-01-01

    We present exact tree-order amplitudes for $H^* \\to n~H$, for final states containing one or two particles with non-zero three-momentum, for various interaction potentials. We show that there are potentials leading to tree amplitudes that satisfy unitarity, not only at threshold but also in the above kinematical configurations and probably beyond. As a by-product, we also calculate $2\\to n$ tree amplitudes at threshold and show that for the unbroken $\\phi^4$ theory they vanish for $n>4~$, for the Standard Model Higgs they vanish for $n\\ge 3~$ and for a model potential, respecting tree-order unitarity, for $n$ even and $n>4~$. Finally, we calculate the imaginary part of the one-loop $1\\to n$ amplitude in both symmetric and spontaneously broken $\\phi^4$ theory.

  2. Realistic Realizations Of Threshold Circuits

    Science.gov (United States)

    Razavi, Hassan M.

    1987-08-01

    Threshold logic, in which each input is weighted, has many theoretical advantages over the standard gate realization, such as reducing the number of gates, interconnections, and power dissipation. However, because of the difficult synthesis procedure and complicated circuit implementation, their use in the design of digital systems is almost nonexistant. In this study, three methods of NMOS realizations are discussed, and their advantages and shortcomings are explored. Also, the possibility of using the methods to realize multi-valued logic is examined.

  3. Root finding with threshold circuits

    Czech Academy of Sciences Publication Activity Database

    Jeřábek, Emil

    2012-01-01

    Roč. 462, Nov 30 (2012), s. 59-69 ISSN 0304-3975 R&D Projects: GA AV ČR IAA100190902; GA MŠk(CZ) 1M0545 Institutional support: RVO:67985840 Keywords : root finding * threshold circuit * power series Subject RIV: BA - General Mathematics Impact factor: 0.489, year: 2012 http://www.sciencedirect.com/science/article/pii/S0304397512008006#

  4. Cross-sections of {sup 45}Sc(n,2n){sup 44m,g}Sc reaction from the reaction threshold to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Luo, J. [Hexi Univ., Zhangye (China). School of Physics and Electromechanical Engineering; Peking Univ., Beijing (China). State Key Laboratory of Nuclear Physics and Technology; Liu, R.; Jiang, L. [Chinese Academy of Engineering Physics, Mianyang (China). Inst. of Nuclear Physics and Chemistry; Liu, Z.; Sun, G.; Ge, S. [Hexi Univ., Zhangye (China). School of Physics and Electromechanical Engineering

    2013-07-01

    Cross sections of {sup 45}Sc(n,2n){sup 44m,g}Sc reactions and their isomeric cross section ratios {sigma}{sub m}/{sigma}{sub g} have been measured at three neutron energies between 13.5 and 14.8 MeV using the activation technique. The pure cross section of the groundstate was then obtained by utilizing the absolute cross section of the metastable state and analysis methods of residual nuclear decay. The monoenergetic neutron beam was produced via the {sup 3}H(d, n){sup 4}He reaction. The cross sections were also estimated with the TALYS-1.2 nuclear model code using different level density options, at neutron energies varying from the reaction threshold to 20 MeV. Results are also discussed and compared with some corresponding values found in the literature. (orig.)

  5. Cross-sections of 45Sc(n,2n)44m,gSc reaction from the reaction threshold to 20 MeV

    International Nuclear Information System (INIS)

    Luo, J.; Peking Univ., Beijing; Liu, R.; Jiang, L.; Liu, Z.; Sun, G.; Ge, S.

    2013-01-01

    Cross sections of 45 Sc(n,2n) 44m,g Sc reactions and their isomeric cross section ratios σ m /σ g have been measured at three neutron energies between 13.5 and 14.8 MeV using the activation technique. The pure cross section of the groundstate was then obtained by utilizing the absolute cross section of the metastable state and analysis methods of residual nuclear decay. The monoenergetic neutron beam was produced via the 3 H(d, n) 4 He reaction. The cross sections were also estimated with the TALYS-1.2 nuclear model code using different level density options, at neutron energies varying from the reaction threshold to 20 MeV. Results are also discussed and compared with some corresponding values found in the literature. (orig.)

  6. Trunk muscle activation during golf swing: Baseline and threshold.

    Science.gov (United States)

    Silva, Luís; Marta, Sérgio; Vaz, João; Fernandes, Orlando; Castro, Maria António; Pezarat-Correia, Pedro

    2013-10-01

    There is a lack of studies regarding EMG temporal analysis during dynamic and complex motor tasks, such as golf swing. The aim of this study is to analyze the EMG onset during the golf swing, by comparing two different threshold methods. Method A threshold was determined using the baseline activity recorded between two maximum voluntary contraction (MVC). Method B threshold was calculated using the mean EMG activity for 1000ms before the 500ms prior to the start of the Backswing. Two different clubs were also studied. Three-way repeated measures ANOVA was used to compare methods, muscles and clubs. Two-way mixed Intraclass Correlation Coefficient (ICC) with absolute agreement was used to determine the methods reliability. Club type usage showed no influence in onset detection. Rectus abdominis (RA) showed the higher agreement between methods. Erector spinae (ES), on the other hand, showed a very low agreement, that might be related to postural activity before the swing. External oblique (EO) is the first being activated, at 1295ms prior impact. There is a similar activation time between right and left muscles sides, although the right EO showed better agreement between methods than left side. Therefore, the algorithms usage is task- and muscle-dependent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Design proposal for door thresholds

    Directory of Open Access Journals (Sweden)

    Smolka Radim

    2017-01-01

    Full Text Available Panels for openings in structures have always been an essential and integral part of buildings. Their importance in terms of a building´s functionality was not recognised. However, the general view on this issue has changed from focusing on big planar segments and critical details to sub-elements of these structures. This does not only focus on the forms of connecting joints but also on the supporting systems that keep the panels in the right position and ensure they function properly. One of the most strained segments is the threshold structure, especially the entrance door threshold structure. It is the part where substantial defects in construction occur in terms of waterproofing, as well as in the static, thermal and technical functions thereof. In conventional buildings, this problem is solved by pulling the floor structure under the entrance door structure and subsequently covering it with waterproofing material. This system cannot work effectively over the long term so local defects occur. A proposal is put forward to solve this problem by installing a sub-threshold door coupler made of composite materials. The coupler is designed so that its variability complies with the required parameters for most door structures on the European market.

  8. Does Absolute Synonymy exist in Owere-Igbo? | Omego | AFRREV ...

    African Journals Online (AJOL)

    Among Igbo linguistic researchers, determining whether absolute synonymy exists in Owere–Igbo, a dialect of the Igbo language predominantly spoken by the people of Owerri, Imo State, Nigeria, has become a thorny issue. While some linguistic scholars strive to establish that absolute synonymy exists in the lexical ...

  9. Absolute tense forms in Tswana | Pretorius | Journal for Language ...

    African Journals Online (AJOL)

    These views were compared in an attempt to put forth an applicable framework for the classification of the tenses in Tswana and to identify the absolute tenses of Tswana. Keywords: tense; simple tenses; compound tenses; absolute tenses; relative tenses; aspect; auxiliary verbs; auxiliary verbal groups; Tswana Opsomming

  10. Absolute calibration of sniffer probes on Wendelstein 7-X

    NARCIS (Netherlands)

    Moseev, D.; Laqua, H.P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.J.; Oosterbeek, J.W.

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of

  11. Absolute/convective secondary instabilities and the role of confinement in free shear layers

    Science.gov (United States)

    Arratia, Cristóbal; Mowlavi, Saviz; Gallaire, François

    2018-05-01

    We study the linear spatiotemporal stability of an infinite row of equal point vortices under symmetric confinement between parallel walls. These rows of vortices serve to model the secondary instability leading to the merging of consecutive (Kelvin-Helmholtz) vortices in free shear layers, allowing us to study how confinement limits the growth of shear layers through vortex pairings. Using a geometric construction akin to a Legendre transform on the dispersion relation, we compute the growth rate of the instability in different reference frames as a function of the frame velocity with respect to the vortices. This approach is verified and complemented with numerical computations of the linear impulse response, fully characterizing the absolute/convective nature of the instability. Similar to results by Healey on the primary instability of parallel tanh profiles [J. Fluid Mech. 623, 241 (2009), 10.1017/S0022112008005284], we observe a range of confinement in which absolute instability is promoted. For a parallel shear layer with prescribed confinement and mixing length, the threshold for absolute/convective instability of the secondary pairing instability depends on the separation distance between consecutive vortices, which is physically determined by the wavelength selected by the previous (primary or pairing) instability. In the presence of counterflow and moderate to weak confinement, small (large) wavelength of the vortex row leads to absolute (convective) instability. While absolute secondary instabilities in spatially developing flows have been previously related to an abrupt transition to a complex behavior, this secondary pairing instability regenerates the flow with an increased wavelength, eventually leading to a convectively unstable row of vortices. We argue that since the primary instability remains active for large wavelengths, a spatially developing shear layer can directly saturate on the wavelength of such a convectively unstable row, by

  12. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  13. A developmental study of latent absolute pitch memory.

    Science.gov (United States)

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  14. Advancing Absolute Calibration for JWST and Other Applications

    Science.gov (United States)

    Rieke, George; Bohlin, Ralph; Boyajian, Tabetha; Carey, Sean; Casagrande, Luca; Deustua, Susana; Gordon, Karl; Kraemer, Kathleen; Marengo, Massimo; Schlawin, Everett; Su, Kate; Sloan, Greg; Volk, Kevin

    2017-10-01

    We propose to exploit the unique optical stability of the Spitzer telescope, along with that of IRAC, to (1) transfer the accurate absolute calibration obtained with MSX on very bright stars directly to two reference stars within the dynamic range of the JWST imagers (and of other modern instrumentation); (2) establish a second accurate absolute calibration based on the absolutely calibrated spectrum of the sun, transferred onto the astronomical system via alpha Cen A; and (3) provide accurate infrared measurements for the 11 (of 15) highest priority stars with no such data but with accurate interferometrically measured diameters, allowing us to optimize determinations of effective temperatures using the infrared flux method and thus to extend the accurate absolute calibration spectrally. This program is integral to plans for an accurate absolute calibration of JWST and will also provide a valuable Spitzer legacy.

  15. Estimation of Cumulative Absolute Velocity using Empirical Green's Function Method

    International Nuclear Information System (INIS)

    Park, Dong Hee; Yun, Kwan Hee; Chang, Chun Joong; Park, Se Moon

    2009-01-01

    In recognition of the needs to develop a new criterion for determining when the OBE (Operating Basis Earthquake) has been exceeded at nuclear power plants, Cumulative Absolute Velocity (CAV) was introduced by EPRI. The concept of CAV is the area accumulation with the values more than 0.025g occurred during every one second. The equation of the CAV is as follows. CAV = ∫ 0 max |a(t)|dt (1) t max = duration of record, a(t) = acceleration (>0.025g) Currently, the OBE exceedance criteria in Korea is Peak Ground Acceleration (PGA, PGA>0.1g). When Odesan earthquake (M L =4.8, January 20th, 2007) and Gyeongju earthquake (M L =3.4, June 2nd, 1999) were occurred, we have had already experiences of PGA greater than 0.1g that did not even cause any damage to the poorly-designed structures nearby. This moderate earthquake has motivated Korea to begin the use of the CAV for OBE exceedance criteria for NPPs. Because the present OBE level has proved itself to be a poor indicator for small-to-moderate earthquakes, for which the low OBE level can cause an inappropriate shut down the plant. A more serious possibility is that this scenario will become a reality at a very high level. Empirical Green's Function method was a simulation technique which can estimate the CAV value and it is hereby introduced

  16. Ultrafuzziness Optimization Based on Type II Fuzzy Sets for Image Thresholding

    Directory of Open Access Journals (Sweden)

    Hudan Studiawan

    2010-11-01

    Full Text Available Image thresholding is one of the processing techniques to provide high quality preprocessed image. Image vagueness and bad illumination are common obstacles yielding in a poor image thresholding output. By assuming image as fuzzy sets, several different fuzzy thresholding techniques have been proposed to remove these obstacles during threshold selection. In this paper, we proposed an algorithm for thresholding image using ultrafuzziness optimization to decrease uncertainty in fuzzy system by common fuzzy sets like type II fuzzy sets. Optimization was conducted by involving ultrafuzziness measurement for background and object fuzzy sets separately. Experimental results demonstrated that the proposed image thresholding method had good performances for images with high vagueness, low level contrast, and grayscale ambiguity.

  17. Color difference thresholds in dentistry.

    Science.gov (United States)

    Paravina, Rade D; Ghinea, Razvan; Herrera, Luis J; Bona, Alvaro D; Igiel, Christopher; Linninger, Mercedes; Sakai, Maiko; Takahashi, Hidekazu; Tashkandi, Esam; Perez, Maria del Mar

    2015-01-01

    The aim of this prospective multicenter study was to determine 50:50% perceptibility threshold (PT) and 50:50% acceptability threshold (AT) of dental ceramic under simulated clinical settings. The spectral radiance of 63 monochromatic ceramic specimens was determined using a non-contact spectroradiometer. A total of 60 specimen pairs, divided into 3 sets of 20 specimen pairs (medium to light shades, medium to dark shades, and dark shades), were selected for psychophysical experiment. The coordinating center and seven research sites obtained the Institutional Review Board (IRB) approvals prior the beginning of the experiment. Each research site had 25 observers, divided into five groups of five observers: dentists-D, dental students-S, dental auxiliaries-A, dental technicians-T, and lay persons-L. There were 35 observers per group (five observers per group at each site ×7 sites), for a total of 175 observers. Visual color comparisons were performed using a viewing booth. Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points. The 50:50% PT and 50:50% AT were determined in CIELAB and CIEDE2000. The t-test was used to evaluate the statistical significance in thresholds differences. The CIELAB 50:50% PT was ΔEab  = 1.2, whereas 50:50% AT was ΔEab  = 2.7. Corresponding CIEDE2000 (ΔE00 ) values were 0.8 and 1.8, respectively. 50:50% PT by the observer group revealed differences among groups D, A, T, and L as compared with 50:50% PT for all observers. The 50:50% AT for all observers was statistically different than 50:50% AT in groups T and L. A 50:50% perceptibility and ATs were significantly different. The same is true for differences between two color difference formulas ΔE00 /ΔEab . Observer groups and sites showed high level of statistical difference in all thresholds. Visual color difference thresholds can serve as a quality control tool to guide the selection of esthetic dental materials, evaluate clinical performance, and

  18. Threshold current for the transverse single-bunch instability in PEP

    International Nuclear Information System (INIS)

    Wilson, P.B.; Rivkin, L.

    1982-08-01

    For a bunch with charge q moving in a storage ring under the influence of a constant dipole wake potential of amplitude W 1 and constant transverse beta-function with amplitude β/sub t/, the two-macroparticle model for the transverse single-bunch instability predicts a threshold current. When this work is completed, an absolute prediction of the threshold current will be possible, at least to the extent that the transverse impedance of the rf cavities dominates the total impedance of the ring. A preliminary estimate of the fraction of the total dipole impedance exterior to the rf cavities is the purposes of this note. 4 refs., 3 tabs

  19. Bedding material affects mechanical thresholds, heat thresholds and texture preference

    Science.gov (United States)

    Moehring, Francie; O’Hara, Crystal L.; Stucky, Cheryl L.

    2015-01-01

    It has long been known that the bedding type animals are housed on can affect breeding behavior and cage environment. Yet little is known about its effects on evoked behavior responses or non-reflexive behaviors. C57BL/6 mice were housed for two weeks on one of five bedding types: Aspen Sani Chips® (standard bedding for our institute), ALPHA-Dri®, Cellu-Dri™, Pure-o’Cel™ or TEK-Fresh. Mice housed on Aspen exhibited the lowest (most sensitive) mechanical thresholds while those on TEK-Fresh exhibited 3-fold higher thresholds. While bedding type had no effect on responses to punctate or dynamic light touch stimuli, TEK-Fresh housed animals exhibited greater responsiveness in a noxious needle assay, than those housed on the other bedding types. Heat sensitivity was also affected by bedding as animals housed on Aspen exhibited the shortest (most sensitive) latencies to withdrawal whereas those housed on TEK-Fresh had the longest (least sensitive) latencies to response. Slight differences between bedding types were also seen in a moderate cold temperature preference assay. A modified tactile conditioned place preference chamber assay revealed that animals preferred TEK-Fresh to Aspen bedding. Bedding type had no effect in a non-reflexive wheel running assay. In both acute (two day) and chronic (5 week) inflammation induced by injection of Complete Freund’s Adjuvant in the hindpaw, mechanical thresholds were reduced in all groups regardless of bedding type, but TEK-Fresh and Pure-o’Cel™ groups exhibited a greater dynamic range between controls and inflamed cohorts than Aspen housed mice. PMID:26456764

  20. SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

    International Nuclear Information System (INIS)

    Chu, A; Ahmad, M; Chen, Z; Nath, R; Feng, W

    2014-01-01

    Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions

  1. SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Chu, A; Ahmad, M; Chen, Z; Nath, R [Yale New Haven Hospital/School of Medicine Yale University, New Haven, CT (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States)

    2014-06-01

    Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions

  2. Threshold-based Adaptive Detection for WSN

    KAUST Repository

    Abuzaid, Abdulrahman I.

    2014-01-06

    Efficient receiver designs for wireless sensor networks (WSNs) are becoming increasingly important. Cooperative WSNs communicated with the use of L sensors. As the receiver is constrained, it can only process U out of L sensors. Channel shortening and reduced-rank techniques were employed to design the preprocessing matrix. In this work, a receiver structure is proposed which combines the joint iterative optimization (JIO) algorithm and our proposed threshold selection criteria. This receiver structure assists in determining the optimal Uopt. It also provides the freedom to choose U

  3. Threshold-based Adaptive Detection for WSN

    KAUST Repository

    Abuzaid, Abdulrahman I.; Ahmed, Qasim Zeeshan; Alouini, Mohamed-Slim

    2014-01-01

    Efficient receiver designs for wireless sensor networks (WSNs) are becoming increasingly important. Cooperative WSNs communicated with the use of L sensors. As the receiver is constrained, it can only process U out of L sensors. Channel shortening and reduced-rank techniques were employed to design the preprocessing matrix. In this work, a receiver structure is proposed which combines the joint iterative optimization (JIO) algorithm and our proposed threshold selection criteria. This receiver structure assists in determining the optimal Uopt. It also provides the freedom to choose U

  4. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  5. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  6. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Zhao, H. L.; Liu, Y., E-mail: liuyong@ipp.ac.cn; Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Domier, C. W.; Luhmann, N. C. [Department of Electrical and Computer Engineering, University of California at Davis, Davis, California 95616 (United States)

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  7. A measurement of the absolute neutron beam polarization produced by an optically pumped 3He neutron spin filter

    International Nuclear Information System (INIS)

    Rich, D.R.; Bowman, J.D.; Crawford, B.E.; Delheij, P.P.J.; Espy, M.A.; Haseyama, T.; Jones, G.; Keith, C.D.; Knudson, J.; Leuschner, M.B.; Masaike, A.; Masuda, Y.; Matsuda, Y.; Penttilae, S.I.; Pomeroy, V.R.; Smith, D.A.; Snow, W.M.; Szymanski, J.J.; Stephenson, S.L.; Thompson, A.K.; Yuan, V.

    2002-01-01

    The capability of performing accurate absolute measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with an absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically pumped polarized 3 He spin filter and a relative transmission measurement technique. 3 He was polarized using the Rb spin-exchange method. We describe the measurement technique, present our results, and discuss some of the systematic effects associated with the method

  8. Levels of alarm thresholds of meningitis outbreaks in Hamadan Province, west of Iran.

    Science.gov (United States)

    Faryadres, Mohammad; Karami, Manoochehr; Moghimbeigi, Abbas; Esmailnasab, Nader; Pazhouhi, Khabat

    2015-01-01

    Few studies have focused on syndromic data to determine levels of alarm thresholds to detection of meningitis outbreaks. The purpose of this study was to determine threshold levels of meningitis outbreak in Hamadan Province, west of Iran. Data on both confirmed and suspected cases of meningitis (fever and neurological symptom) form 21 March 2010 to 20 March 2012 were used in Hamadan Province, Iran. Alarm threshold levels of meningitis outbreak were determined using four different methods including absolute values or standard method, relative increase, statistical cutoff points and upper control limit of exponentially weighted moving average (EWMA) algorithm. Among 723 reported cases, 41 were diagnosed to have meningitis. Standard level of alarm thresholds for meningitis outbreak was determined as incidence of 5/100000 persons. Increasing 1.5 to two times in reported cases of suspected meningitis per week was known as the threshold levels according to relative increase method. An occurrence four cases of suspected meningitis per week that equals to 90th percentile was chosen as alarm thresholds by statistical cut off point method. The corresponding value according to EWMA algorithm was 2.57 i.e. three cases. Policy makers and staff of syndromic surveillance systems are highly recommended to apply the above different methods to determine the levels of alarm threshold.

  9. Carbon Nanotube Bolometer for Absolute FTIR Spectroscopy

    Science.gov (United States)

    Woods, Solomon; Neira, Jorge; Tomlin, Nathan; Lehman, John

    We have developed and calibrated planar electrical-substitution bolometers which employ absorbers made from vertically-aligned carbon nanotube arrays. The nearly complete absorption of light by the carbon nanotubes from the visible range to the far-infrared can be exploited to enable a device with read-out in native units equivalent to optical power. Operated at cryogenic temperatures near 4 K, these infrared detectors are designed to have time constant near 10 ms and a noise floor of about 10 pW. Built upon a micro-machined silicon platform, each device has an integrated heater and thermometer, either a carbon nanotube thermistor or superconducting transition edge sensor, for temperature control. We are optimizing temperature-controlled measurement techniques to enable high resolution spectral calibrations using these devices with a Fourier-transform spectrometer.

  10. Absolute measurements methods for proton beam dosimetry

    International Nuclear Information System (INIS)

    Laitano, R.F.

    1998-01-01

    A widespread interest in improving proton beam characteristics and related dosimetry became apparent in the recent years, even if the advantages of protons in radiotherapy were pointed out since 1946. The early treatments by proton beams were made for a long time on a small number of patients in very few accelerators sharing their use with nuclear-physics experiments. The first proton accelerator totally dedicated to radiotherapy was established just in 1990 at the Loma Linda Medical Center in the USA. A further reason of the slowly growing use of protons for therapy in the early years, was the lack of adequate means for accurate localization of the treatment volume. The potentialities of protons in imparting a largest part of their energy to very small volumes became exploitable only after the established clinical use of accurate imaging techniques such as based on CT, NMR, PET, etc

  11. Optimizing Systems of Threshold Detection Sensors

    National Research Council Canada - National Science Library

    Banschbach, David C

    2008-01-01

    .... Below the threshold all signals are ignored. We develop a mathematical model for setting individual sensor thresholds to obtain optimal probability of detecting a significant event, given a limit on the total number of false positives allowed...

  12. 11 CFR 9036.1 - Threshold submission.

    Science.gov (United States)

    2010-01-01

    ... credit or debit card, including one made over the Internet, the candidate shall provide sufficient... section shall not count toward the threshold amount. (c) Threshold certification by Commission. (1) After...

  13. Nuclear thermodynamics below particle threshold

    International Nuclear Information System (INIS)

    Schiller, A.; Agvaanluvsan, U.; Algin, E.; Bagheri, A.; Chankova, R.; Guttormsen, M.; Hjorth-Jensen, M.; Rekstad, J.; Siem, S.; Sunde, A. C.; Voinov, A.

    2005-01-01

    From a starting point of experimentally measured nuclear level densities, we discuss thermodynamical properties of nuclei below the particle emission threshold. Since nuclei are essentially mesoscopic systems, a straightforward generalization of macroscopic ensemble theory often yields unphysical results. A careful critique of traditional thermodynamical concepts reveals problems commonly encountered in mesoscopic systems. One of which is the fact that microcanonical and canonical ensemble theory yield different results, another concerns the introduction of temperature for small, closed systems. Finally, the concept of phase transitions is investigated for mesoscopic systems

  14. Characterizing absolute piezoelectric microelectromechanical system displacement using an atomic force microscope

    International Nuclear Information System (INIS)

    Evans, J.; Chapman, S.

    2014-01-01

    Piezoresponse Force Microscopy (PFM) is a popular tool for the study of ferroelectric and piezoelectric materials at the nanometer level. Progress in the development of piezoelectric MEMS fabrication is highlighting the need to characterize absolute displacement at the nanometer and Ångstrom scales, something Atomic Force Microscopy (AFM) might do but PFM cannot. Absolute displacement is measured by executing a polarization measurement of the ferroelectric or piezoelectric capacitor in question while monitoring the absolute vertical position of the sample surface with a stationary AFM cantilever. Two issues dominate the execution and precision of such a measurement: (1) the small amplitude of the electrical signal from the AFM at the Ångstrom level and (2) calibration of the AFM. The authors have developed a calibration routine and test technique for mitigating the two issues, making it possible to use an atomic force microscope to measure both the movement of a capacitor surface as well as the motion of a micro-machine structure actuated by that capacitor. The theory, procedures, pitfalls, and results of using an AFM for absolute piezoelectric measurement are provided

  15. Characterizing absolute piezoelectric microelectromechanical system displacement using an atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Evans, J., E-mail: radiant@ferrodevices.com; Chapman, S., E-mail: radiant@ferrodevices.com [Radiant Technologies, Inc., 2835C Pan American Fwy NE, Albuquerque, New Mexico 87107 (United States)

    2014-08-14

    Piezoresponse Force Microscopy (PFM) is a popular tool for the study of ferroelectric and piezoelectric materials at the nanometer level. Progress in the development of piezoelectric MEMS fabrication is highlighting the need to characterize absolute displacement at the nanometer and Ångstrom scales, something Atomic Force Microscopy (AFM) might do but PFM cannot. Absolute displacement is measured by executing a polarization measurement of the ferroelectric or piezoelectric capacitor in question while monitoring the absolute vertical position of the sample surface with a stationary AFM cantilever. Two issues dominate the execution and precision of such a measurement: (1) the small amplitude of the electrical signal from the AFM at the Ångstrom level and (2) calibration of the AFM. The authors have developed a calibration routine and test technique for mitigating the two issues, making it possible to use an atomic force microscope to measure both the movement of a capacitor surface as well as the motion of a micro-machine structure actuated by that capacitor. The theory, procedures, pitfalls, and results of using an AFM for absolute piezoelectric measurement are provided.

  16. Absolute photoabsorption cross-sections (oscillator strengths) for hydrogen chloride, hydrogen bromide and hydrogen iodide

    International Nuclear Information System (INIS)

    Brion, C.E.; Dyck, M.; Cooper, G.

    2004-01-01

    Full text: Absolute photoabsorption cross-sections (oscillator strengths) for the free molecules HCl, HBr and HI have been measured in the valence and selected in- ner shell regions. The experimental technique used for these studies is dipole (e,e) spectroscopy [1-3] which is not affected by line saturation effects (i.e. bandwidth interactions) which can complicate direct photoabsorption methods using the Beer- Lambert law. The dipole (e,e) method is also not subject to the effects of higher order radiation. In the dipole (e,e) method relative intensities obtained in fast (3 keV) for- ward scattered electron energy loss spectra are converted to relative dipole oscillator strengths (i.e. photoabsorption spectra) using the known Bethe-Born factors for the instrument as a function of photon energy (i.e. energy loss). The target pressure is constant at 10 - 5 torr, but it is not necessary to know the absolute target density. The absolute oscillator strength scale for HCl is determined from Bethe-Born converted, wide range dipole (e,e) spectra using the Thomas-Reiche-Kuhn (TRK) sum rule. For HBr and HI the absolute oscillator strength scales have been established using the S(-2) Sum Rule and literature values of the static dipole polarizability

  17. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  18. Orion Absolute Navigation System Progress and Challenges

    Science.gov (United States)

    Holt, Greg N.; D'Souza, Christopher

    2011-01-01

    The Orion spacecraft is being designed as NASA's next-generation exploration vehicle for crewed missions beyond Low-Earth Orbit. The navigation system for the Orion spacecraft is being designed in a Multi-Organizational Design Environment (MODE) team including contractor and NASA personnel. The system uses an Extended Kalman Filter to process measurements and determine the state. The design of the navigation system has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudorange and deltarange, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, pad alignment, cold start are discussed as are

  19. Compositional threshold for Nuclear Waste Glass Durability

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Farooqi, Rahmatullah; Hrma, Pavel R.

    2013-01-01

    Within the composition space of glasses, a distinct threshold appears to exist that separates 'good' glasses, i.e., those which are sufficiently durable, from 'bad' glasses of a low durability. The objective of our research is to clarify the origin of this threshold by exploring the relationship between glass composition, glass structure and chemical durability around the threshold region

  20. Threshold Concepts in Finance: Student Perspectives

    Science.gov (United States)

    Hoadley, Susan; Kyng, Tim; Tickle, Leonie; Wood, Leigh N.

    2015-01-01

    Finance threshold concepts are the essential conceptual knowledge that underpin well-developed financial capabilities and are central to the mastery of finance. In this paper we investigate threshold concepts in finance from the point of view of students, by establishing the extent to which students are aware of threshold concepts identified by…

  1. Application of Individualized Speed Thresholds to Interpret Position Specific Running Demands in Elite Professional Rugby Union: A GPS Study.

    Directory of Open Access Journals (Sweden)

    Cillian Reardon

    Full Text Available A number of studies have used GPS technology to categorise rugby union locomotive demands. However, the utility of the results of these studies is confounded by small sample sizes, sub-elite player status and the global application of absolute speed thresholds to all player positions. Furthermore, many of these studies have used GPS units with low sampling frequencies. The aim of the present study was to compare and contrast the high speed running (HSR demands of professional rugby union when utilizing micro-technology units sampling at 10 Hz and applying relative or individualised speed zones. The results of this study indicate that application of individualised speed zones results in a significant shift in the interpretation of the HSR demands of both forwards and backs and positional sub-categories therein. When considering the use of an absolute in comparison to an individualised HSR threshold, there was a significant underestimation for forwards of HSR distance (HSRD (absolute = 269 ± 172.02, individualised = 354.72 ± 99.22, p < 0.001, HSR% (absolute = 5.15 ± 3.18, individualised = 7.06 ± 2.48, p < 0.001 and HSR efforts (HSRE (absolute = 18.81 ± 12.25; individualised = 24.78 ± 8.30, p < 0.001. In contrast, there was a significant overestimation of the same HSR metrics for backs with the use of an absolute threshold (HSRD absolute = 697.79 ± 198.11, individualised = 570.02 ± 171.14, p < 0.001; HSR% absolute = 10.85 ± 2.82, individualised = 8.95 ± 2.76, p < 0.001; HSRE absolute = 41.55 ± 11.25; individualised = 34.54 ± 9.24, p < 0.001. This under- or overestimation associated with an absolute speed zone applies to varying degrees across the ten positional sub-categories analyzed and also to individuals within the same positional sub-category. The results of the present study indicated that although use of an individulised HSR threshold improves the interpretation of the HSR demands on a positional basis, inter

  2. Improved Bat Algorithm Applied to Multilevel Image Thresholding

    Directory of Open Access Journals (Sweden)

    Adis Alihodzic

    2014-01-01

    Full Text Available Multilevel image thresholding is a very important image processing technique that is used as a basis for image segmentation and further higher level processing. However, the required computational time for exhaustive search grows exponentially with the number of desired thresholds. Swarm intelligence metaheuristics are well known as successful and efficient optimization methods for intractable problems. In this paper, we adjusted one of the latest swarm intelligence algorithms, the bat algorithm, for the multilevel image thresholding problem. The results of testing on standard benchmark images show that the bat algorithm is comparable with other state-of-the-art algorithms. We improved standard bat algorithm, where our modifications add some elements from the differential evolution and from the artificial bee colony algorithm. Our new proposed improved bat algorithm proved to be better than five other state-of-the-art algorithms, improving quality of results in all cases and significantly improving convergence speed.

  3. Pairing based threshold cryptography improving on Libert-Quisquater and Baek-Zheng

    DEFF Research Database (Denmark)

    Desmedt, Yvo; Lange, Tanja

    2006-01-01

    In this paper we apply techniques from secret sharing and threshold decryption to show how to properly design an ID-based threshold system in which one assumes no trust in any party. In our scheme: We avoid that any single machine ever knew the master secret s of the trusted authority (TA). Inste...

  4. Absolute density measurements in the middle atmosphere

    Directory of Open Access Journals (Sweden)

    M. Rapp

    2001-05-01

    Full Text Available In the last ten years a total of 25 sounding rockets employing ionization gauges have been launched at high latitudes ( ~ 70° N to measure total atmospheric density and its small scale fluctuations in an altitude range between 70 and 110 km. While the determination of small scale fluctuations is unambiguous, the total density analysis has been complicated in the past by aerodynamical disturbances leading to densities inside the sensor which are enhanced compared to atmospheric values. Here, we present the results of both Monte Carlo simulations and wind tunnel measurements to quantify this aerodynamical effect. The comparison of the resulting ‘ram-factor’ profiles with empirically determined density ratios of ionization gauge measurements and falling sphere measurements provides excellent agreement. This demonstrates both the need, but also the possibility, to correct aerodynamical influences on measurements from sounding rockets. We have determined a total of 20 density profiles of the mesosphere-lower-thermosphere (MLT region. Grouping these profiles according to season, a listing of mean density profiles is included in the paper. A comparison with density profiles taken from the reference atmospheres CIRA86 and MSIS90 results in differences of up to 40%. This reflects that current reference atmospheres are a significant potential error source for the determination of mixing ratios of, for example, trace gas constituents in the MLT region.Key words. Middle atmosphere (composition and chemistry; pressure, density, and temperature; instruments and techniques

  5. Absolute density measurements in the middle atmosphere

    Directory of Open Access Journals (Sweden)

    M. Rapp

    Full Text Available In the last ten years a total of 25 sounding rockets employing ionization gauges have been launched at high latitudes ( ~ 70° N to measure total atmospheric density and its small scale fluctuations in an altitude range between 70 and 110 km. While the determination of small scale fluctuations is unambiguous, the total density analysis has been complicated in the past by aerodynamical disturbances leading to densities inside the sensor which are enhanced compared to atmospheric values. Here, we present the results of both Monte Carlo simulations and wind tunnel measurements to quantify this aerodynamical effect. The comparison of the resulting ‘ram-factor’ profiles with empirically determined density ratios of ionization gauge measurements and falling sphere measurements provides excellent agreement. This demonstrates both the need, but also the possibility, to correct aerodynamical influences on measurements from sounding rockets. We have determined a total of 20 density profiles of the mesosphere-lower-thermosphere (MLT region. Grouping these profiles according to season, a listing of mean density profiles is included in the paper. A comparison with density profiles taken from the reference atmospheres CIRA86 and MSIS90 results in differences of up to 40%. This reflects that current reference atmospheres are a significant potential error source for the determination of mixing ratios of, for example, trace gas constituents in the MLT region.

    Key words. Middle atmosphere (composition and chemistry; pressure, density, and temperature; instruments and techniques

  6. Epidemic threshold in directed networks

    Science.gov (United States)

    Li, Cong; Wang, Huijuan; Van Mieghem, Piet

    2013-12-01

    Epidemics have so far been mostly studied in undirected networks. However, many real-world networks, such as the online social network Twitter and the world wide web, on which information, emotion, or malware spreads, are directed networks, composed of both unidirectional links and bidirectional links. We define the directionality ξ as the percentage of unidirectional links. The epidemic threshold τc for the susceptible-infected-susceptible (SIS) epidemic is lower bounded by 1/λ1 in directed networks, where λ1, also called the spectral radius, is the largest eigenvalue of the adjacency matrix. In this work, we propose two algorithms to generate directed networks with a given directionality ξ. The effect of ξ on the spectral radius λ1, principal eigenvector x1, spectral gap (λ1-λ2), and algebraic connectivity μN-1 is studied. Important findings are that the spectral radius λ1 decreases with the directionality ξ, whereas the spectral gap and the algebraic connectivity increase with the directionality ξ. The extent of the decrease of the spectral radius depends on both the degree distribution and the degree-degree correlation ρD. Hence, in directed networks, the epidemic threshold is larger and a random walk converges to its steady state faster than that in undirected networks with the same degree distribution.

  7. Computational gestalts and perception thresholds.

    Science.gov (United States)

    Desolneux, Agnès; Moisan, Lionel; Morel, Jean-Michel

    2003-01-01

    In 1923, Max Wertheimer proposed a research programme and method in visual perception. He conjectured the existence of a small set of geometric grouping laws governing the perceptual synthesis of phenomenal objects, or "gestalt" from the atomic retina input. In this paper, we review this set of geometric grouping laws, using the works of Metzger, Kanizsa and their schools. In continuation, we explain why the Gestalt theory research programme can be translated into a Computer Vision programme. This translation is not straightforward, since Gestalt theory never addressed two fundamental matters: image sampling and image information measurements. Using these advances, we shall show that gestalt grouping laws can be translated into quantitative laws allowing the automatic computation of gestalts in digital images. From the psychophysical viewpoint, a main issue is raised: the computer vision gestalt detection methods deliver predictable perception thresholds. Thus, we are set in a position where we can build artificial images and check whether some kind of agreement can be found between the computationally predicted thresholds and the psychophysical ones. We describe and discuss two preliminary sets of experiments, where we compared the gestalt detection performance of several subjects with the predictable detection curve. In our opinion, the results of this experimental comparison support the idea of a much more systematic interaction between computational predictions in Computer Vision and psychophysical experiments.

  8. Threshold enhancement of diphoton resonances

    CERN Document Server

    Bharucha, Aoife; Goudelis, Andreas

    2016-10-10

    The data collected by the LHC collaborations at an energy of 13 TeV indicates the presence of an excess in the diphoton spectrum that would correspond to a resonance of a 750 GeV mass. The apparently large production cross section is nevertheless very difficult to explain in minimal models. We consider the possibility that the resonance is a pseudoscalar boson $A$ with a two--photon decay mediated by a charged and uncolored fermion having a mass at the $\\frac12 M_A$ threshold and a very small decay width, $\\ll 1$ MeV; one can then generate a large enhancement of the $A\\gamma\\gamma$ amplitude which explains the excess without invoking a large multiplicity of particles propagating in the loop, large electric charges and/or very strong Yukawa couplings. The implications of such a threshold enhancement are discussed in two explicit scenarios: i) the Minimal Supersymmetric Standard Model in which the $A$ state is produced via the top quark mediated gluon fusion process and decays into photons predominantly through...

  9. Quantifying the Arousal Threshold Using Polysomnography in Obstructive Sleep Apnea.

    Science.gov (United States)

    Sands, Scott A; Terrill, Philip I; Edwards, Bradley A; Taranto Montemurro, Luigi; Azarbarzin, Ali; Marques, Melania; de Melo, Camila M; Loring, Stephen H; Butler, James P; White, David P; Wellman, Andrew

    2018-01-01

    Precision medicine for obstructive sleep apnea (OSA) requires noninvasive estimates of each patient's pathophysiological "traits." Here, we provide the first automated technique to quantify the respiratory arousal threshold-defined as the level of ventilatory drive triggering arousal from sleep-using diagnostic polysomnographic signals in patients with OSA. Ventilatory drive preceding clinically scored arousals was estimated from polysomnographic studies by fitting a respiratory control model (Terrill et al.) to the pattern of ventilation during spontaneous respiratory events. Conceptually, the magnitude of the airflow signal immediately after arousal onset reveals information on the underlying ventilatory drive that triggered the arousal. Polysomnographic arousal threshold measures were compared with gold standard values taken from esophageal pressure and intraoesophageal diaphragm electromyography recorded simultaneously (N = 29). Comparisons were also made to arousal threshold measures using continuous positive airway pressure (CPAP) dial-downs (N = 28). The validity of using (linearized) nasal pressure rather than pneumotachograph ventilation was also assessed (N = 11). Polysomnographic arousal threshold values were correlated with those measured using esophageal pressure and diaphragm EMG (R = 0.79, p < .0001; R = 0.73, p = .0001), as well as CPAP manipulation (R = 0.73, p < .0001). Arousal threshold estimates were similar using nasal pressure and pneumotachograph ventilation (R = 0.96, p < .0001). The arousal threshold in patients with OSA can be estimated using polysomnographic signals and may enable more personalized therapeutic interventions for patients with a low arousal threshold. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  10. Efficacy of intrahepatic absolute alcohol in unrespectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Hameed, K.; Khan, I.U.; Shah, S.

    2001-01-01

    To determine efficacy of intrahepatic absolute alcohol injection in researchable hepatocellular carcinoma. A randomized, controlled, experimental and interventional clinical trial. Gastroenterology Department, PGMI, Hayatabad Medical Complex, Peshawar during the period from June, 1998 to June, 2000. Thirty patients were treated by percutaneous, intrahepatic absolute alcohol injection sin repeated sessions, 33 patients were not given or treated with alcohol to serve as control. Both the groups were comparable for age, sex and other baseline characteristics. Absolute alcohol therapy significantly improved quality of life of patients, reduced the tumor size and mortality as well as showed significantly better results regarding survival (P< 0.05) than the patients of control group. We conclude that absolute alcohol is a beneficial and safe palliative treatment measure in advanced hepatocellular carcinoma (HCC). (author)

  11. DOES ABSOLUTE SYNONYMY EXIST IN OWERE-IGBO?

    African Journals Online (AJOL)

    USER

    The researcher also interviewed native speakers of the dialect. The study ... The word 'synonymy' means sameness of meaning, i.e., a relationship in which more ... whether absolute synonymy exists in Owere–Igbo or not. ..... 'close this book'.

  12. Prognostic Value of Absolute versus Relative Rise of Blood ...

    African Journals Online (AJOL)

    maternal outcome than a relative rise in the systolic/diastolic blood pressure from mid pregnancy, which did not reach this absolute level. We conclude that in the Nigerian obstetric population, the practice of diagnosing pregnancy hypertension on ...

  13. Absolute calibration of sniffer probes on Wendelstein 7-X

    International Nuclear Information System (INIS)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-01-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m 2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m 2 per MW injected beam power is measured.

  14. Absolute calibration of sniffer probes on Wendelstein 7-X

    Science.gov (United States)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m2 per MW injected beam power is measured.

  15. Absolute calibration of sniffer probes on Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Moseev, D., E-mail: dmitry.moseev@ipp.mpg.de; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Gellert, F. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Ernst-Moritz-Arndt-Universität Greifswald, Greifswald (Germany); Oosterbeek, J. W. [Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-08-15

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m{sup 2} per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m{sup 2} per MW injected beam power is measured.

  16. Probative value of absolute and relative judgments in eyewitness identification.

    Science.gov (United States)

    Clark, Steven E; Erickson, Michael A; Breneman, Jesse

    2011-10-01

    It is well-accepted that eyewitness identification decisions based on relative judgments are less accurate than identification decisions based on absolute judgments. However, the theoretical foundation for this view has not been established. In this study relative and absolute judgments were compared through simulations of the WITNESS model (Clark, Appl Cogn Psychol 17:629-654, 2003) to address the question: Do suspect identifications based on absolute judgments have higher probative value than suspect identifications based on relative judgments? Simulations of the WITNESS model showed a consistent advantage for absolute judgments over relative judgments for suspect-matched lineups. However, simulations of same-foils lineups showed a complex interaction based on the accuracy of memory and the similarity relationships among lineup members.

  17. Changes in Absolute Sea Level Along U.S. Coasts

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map shows changes in absolute sea level from 1960 to 2016 based on satellite measurements. Data were adjusted by applying an inverted barometer (air pressure)...

  18. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.; Krishnan, Shyam; Stoltz, Brian M.

    2011-01-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional

  19. Adaptive local thresholding for robust nucleus segmentation utilizing shape priors

    Science.gov (United States)

    Wang, Xiuzhong; Srinivas, Chukka

    2016-03-01

    This paper describes a novel local thresholding method for foreground detection. First, a Canny edge detection method is used for initial edge detection. Then, tensor voting is applied on the initial edge pixels, using a nonsymmetric tensor field tailored to encode prior information about nucleus size, shape, and intensity spatial distribution. Tensor analysis is then performed to generate the saliency image and, based on that, the refined edge. Next, the image domain is divided into blocks. In each block, at least one foreground and one background pixel are sampled for each refined edge pixel. The saliency weighted foreground histogram and background histogram are then created. These two histograms are used to calculate a threshold by minimizing the background and foreground pixel classification error. The block-wise thresholds are then used to generate the threshold for each pixel via interpolation. Finally, the foreground is obtained by comparing the original image with the threshold image. The effective use of prior information, combined with robust techniques, results in far more reliable foreground detection, which leads to robust nucleus segmentation.

  20. Spatiotemporal Evolution of Stimulated Raman Scattering in the Absolute and Convective Regimes

    International Nuclear Information System (INIS)

    Feng Wu; Li Xibo; Zheng Chunyang

    2013-01-01

    A three-wave interaction (3WI) code is developed to study the stimulated Raman scattering (SRS) in both absolute and convective regimes. In the simulations, the time and spatial evolutions of a plasma wave are described by temporal growth rate and spatial factor, respectively. The spatial factors in different phases and different instability regimes are investigated. It is found that the spatial factor is caused by the finite velocity of the pump wave in the first phase and by damping in the last phase. With inclusion of the spatial factor, the temporal growth rate decreases and the threshold for SRS for a finite frequency mismatch increases. Meanwhile, the effects of wave frequency mismatch on the temporal growth rate are also discussed. (basic plasma phenomena)

  1. A proposal to measure absolute environmental sustainability in lifecycle assessment

    DEFF Research Database (Denmark)

    Bjørn, Anders; Margni, Manuele; Roy, Pierre-Olivier

    2016-01-01

    sustainable are therefore increasingly important. Such absolute indicators exist, but suffer from shortcomings such as incomplete coverage of environmental issues, varying data quality and varying or insufficient spatial resolution. The purpose of this article is to demonstrate that life cycle assessment (LCA...... in supporting decisions aimed at simultaneously reducing environmental impacts efficiently and maintaining or achieving environmental sustainability. We have demonstrated that LCA indicators can be modified from being relative to being absolute indicators of environmental sustainability. Further research should...

  2. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    OpenAIRE

    Sammie eTarenskeen; Mirjam eBroersma; Mirjam eBroersma; Bart eGeurts

    2015-01-01

    The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a bet...

  3. Overspecification of color, pattern, and size: salience, absoluteness, and consistency

    OpenAIRE

    Tarenskeen, S.L.; Broersma, M.; Geurts, B.

    2015-01-01

    The rates of overspecification of color, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Color and pattern are absolute and salient attributes, whereas size is relative and less salient. Additionally, a tendency toward consistent responses is assessed. Using a within-participants design, we find similar rates of color and pattern overspecification, which are both higher than the rate of size overspecification. Usi...

  4. The Pragmatics of "Unruly" Dative Absolutes in Early Slavic

    Directory of Open Access Journals (Sweden)

    Daniel E. Collins

    2011-08-01

    Full Text Available This chapter examines some uses of the dative absolute in Old Church Slavonic and in early recensional Slavonic texts that depart from notions of how Indo-European absolute constructions should behave, either because they have subjects coreferential with the (putative main-clause subjects or because they function as if they were main clauses in their own right. Such "noncanonical" absolutes have generally been written off as mechanistic translations or as mistakes by scribes who did not understand the proper uses of the construction. In reality, the problem is not with literalistic translators or incompetent scribes but with the definition of the construction itself; it is quite possible to redefine the Early Slavic dative absolute in a way that accounts for the supposedly deviant cases. While the absolute is generally dependent semantically on an adjacent unit of discourse, it should not always be regarded as subordinated syntactically. There are good grounds for viewing some absolutes not as dependent clauses but as independent sentences whose collateral character is an issue not of syntax but of the pragmatics of discourse.

  5. Accurate absolute measurement of trapped Cs atoms in a MOT

    International Nuclear Information System (INIS)

    Talavera O, M.; Lopez R, M.; Carlos L, E. de; Jimenez S, S.

    2007-01-01

    A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrologia, CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (σ + - σ - ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is l MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to 6 x 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%. (Author)

  6. Intraplate Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K. G.; Camelbeeck, T.

    2007-12-01

    We have conducted repeated absolute gravity (AG) measurements across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken since 2000 and repeated twice a year. Our analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36.7 nm s-2/year equivalent to 18.4 mm/yr is due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nms-2 to 43±29 nms-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. In Ostend, the AG time series agrees with tide gauge data, global mean sea level and altimeter measurements but disagrees with the CGPS. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes in an intraplate context.

  7. Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K.; Camelbeeck, T.

    2009-05-01

    Repeated absolute gravity (AG) measurements have been performed across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken in 2000 and repeated twice a year. Analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36 nm -2/year, equivalent to 18 mm/yr, is at least in parts due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nm s-2 to 43±29 nm s-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes.

  8. Fringe order correction for the absolute phase recovered by two selected spatial frequency fringe projections in fringe projection profilometry.

    Science.gov (United States)

    Ding, Yi; Peng, Kai; Yu, Miao; Lu, Lei; Zhao, Kun

    2017-08-01

    The performance of the two selected spatial frequency phase unwrapping methods is limited by a phase error bound beyond which errors will occur in the fringe order leading to a significant error in the recovered absolute phase map. In this paper, we propose a method to detect and correct the wrong fringe orders. Two constraints are introduced during the fringe order determination of two selected spatial frequency phase unwrapping methods. A strategy to detect and correct the wrong fringe orders is also described. Compared with the existing methods, we do not need to estimate the threshold associated with absolute phase values to determine the fringe order error, thus making it more reliable and avoiding the procedure of search in detecting and correcting successive fringe order errors. The effectiveness of the proposed method is validated by the experimental results.

  9. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature.

    Science.gov (United States)

    Schmuck, S; Fessey, J; Gerbaud, T; Alper, B; Beurskens, M N A; de la Luna, E; Sirinelli, A; Zerbini, M

    2012-12-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron temperature is determined from the measurements. The current state of the interferometer hardware, the calibration setup, and the analysis technique for calibration and plasma operation are described. A new, full-system, absolute calibration employing continuous data acquisition has been performed recently and the calibration method and results are presented. The noise level in the measurement is very low and as a result the electron cyclotron emission spectrum and thus the spatial profile of the electron temperature are determined to within ±5% and in the most relevant region to within ±2%. The new calibration shows that the absolute response of the system has decreased by about 15% compared to that measured previously and possible reasons for this change are presented. Temperature profiles measured with the Michelson interferometer are compared with profiles measured independently using Thomson scattering diagnostics, which have also been recently refurbished and recalibrated, and agreement within experimental uncertainties is obtained.

  10. Risk thresholds for alcohol consumption

    DEFF Research Database (Denmark)

    Wood, Angela M; Kaptoge, Stephen; Butterworth, Adam S

    2018-01-01

    previous cardiovascular disease. METHODS: We did a combined analysis of individual-participant data from three large-scale data sources in 19 high-income countries (the Emerging Risk Factors Collaboration, EPIC-CVD, and the UK Biobank). We characterised dose-response associations and calculated hazard......BACKGROUND: Low-risk limits recommended for alcohol consumption vary substantially across different national guidelines. To define thresholds associated with lowest risk for all-cause mortality and cardiovascular disease, we studied individual-participant data from 599 912 current drinkers without......·4 million person-years of follow-up. For all-cause mortality, we recorded a positive and curvilinear association with the level of alcohol consumption, with the minimum mortality risk around or below 100 g per week. Alcohol consumption was roughly linearly associated with a higher risk of stroke (HR per 100...

  11. Detection thresholds of macaque otolith afferents.

    Science.gov (United States)

    Yu, Xiong-Jie; Dickman, J David; Angelaki, Dora E

    2012-06-13

    The vestibular system is our sixth sense and is important for spatial perception functions, yet the sensory detection and discrimination properties of vestibular neurons remain relatively unexplored. Here we have used signal detection theory to measure detection thresholds of otolith afferents using 1 Hz linear accelerations delivered along three cardinal axes. Direction detection thresholds were measured by comparing mean firing rates centered on response peak and trough (full-cycle thresholds) or by comparing peak/trough firing rates with spontaneous activity (half-cycle thresholds). Thresholds were similar for utricular and saccular afferents, as well as for lateral, fore/aft, and vertical motion directions. When computed along the preferred direction, full-cycle direction detection thresholds were 7.54 and 3.01 cm/s(2) for regular and irregular firing otolith afferents, respectively. Half-cycle thresholds were approximately double, with excitatory thresholds being half as large as inhibitory thresholds. The variability in threshold among afferents was directly related to neuronal gain and did not depend on spike count variance. The exact threshold values depended on both the time window used for spike count analysis and the filtering method used to calculate mean firing rate, although differences between regular and irregular afferent thresholds were independent of analysis parameters. The fact that minimum thresholds measured in macaque otolith afferents are of the same order of magnitude as human behavioral thresholds suggests that the vestibular periphery might determine the limit on our ability to detect or discriminate small differences in head movement, with little noise added during downstream processing.

  12. On the absolute photoionization cross section and dissociative photoionization of cyclopropenylidene.

    Science.gov (United States)

    Holzmeier, Fabian; Fischer, Ingo; Kiendl, Benjamin; Krueger, Anke; Bodi, Andras; Hemberger, Patrick

    2016-04-07

    We report the determination of the absolute photoionization cross section of cyclopropenylidene, c-C3H2, and the heat of formation of the C3H radical and ion derived by the dissociative ionization of the carbene. Vacuum ultraviolet (VUV) synchrotron radiation as provided by the Swiss Light Source and imaging photoelectron photoion coincidence (iPEPICO) were employed. Cyclopropenylidene was generated by pyrolysis of a quadricyclane precursor in a 1 : 1 ratio with benzene, which enabled us to derive the carbene's near threshold absolute photoionization cross section from the photoionization yield of the two pyrolysis products and the known cross section of benzene. The cross section at 9.5 eV, for example, was determined to be 4.5 ± 1.4 Mb. Upon dissociative ionization the carbene decomposes by hydrogen atom loss to the linear isomer of C3H(+). The appearance energy for this process was determined to be AE(0K)(c-C3H2; l-C3H(+)) = 13.67 ± 0.10 eV. The heat of formation of neutral and cationic C3H was derived from this value via a thermochemical cycle as Δ(f)H(0K)(C3H) = 725 ± 25 kJ mol(-1) and Δ(f)H(0K)(C3H(+)) = 1604 ± 19 kJ mol(-1), using a previously reported ionization energy of C3H.

  13. Absolute or relative? A comparative analysis of the relationship between poverty and mortality.

    Science.gov (United States)

    Fritzell, Johan; Rehnberg, Johan; Bacchus Hertzman, Jennie; Blomgren, Jenni

    2015-01-01

    We aimed to examine the cross-national and cross-temporal association between poverty and mortality, in particular differentiating the impact of absolute and relative poverty. We employed pooled cross-sectional time series analysis. Our measure of relative poverty was based upon the standard 60% of median income. The measure of absolute, or fixed, poverty was based upon the US poverty threshold. Our analyses were conducted on data for 30 countries between 1978 and 2010, a total of 149 data points. We separately studied infant, child, and adult mortality. Our findings highlight the importance of relative poverty for mortality. Especially for infant and child mortality, we found that our estimates of fixed poverty is close to zero either in the crude models, or when adjusting for gross domestic product. Conversely, the relative poverty estimates increased when adjusting for confounders. Our results seemed robust to a number of sensitivity tests. If we agree that risk of death is important, the public policy implication of our findings is that relative poverty, which has close associations to overall inequality, should be a major concern also among rich countries.

  14. Accurate measurement of absolute experimental inelastic mean free paths and EELS differential cross-sections

    Energy Technology Data Exchange (ETDEWEB)

    Craven, Alan J.; Bobynko, Joanna; Sala, Bianca; MacLaren, Ian, E-mail: ian.maclaren@glasgow.ac.uk

    2016-11-15

    Methods are described for measuring accurate absolute experimental inelastic mean free paths and differential cross-sections using DualEELS. The methods remove the effects of surface layers and give the results for the bulk materials. The materials used are VC{sub 0.83}, TiC{sub 0.98}, VN{sub 0.97} and TiN{sub 0.88} but the method should be applicable to a wide range of materials. The data was taken at 200 keV using a probe half angle of 29 mrad and a collection angle of 36 mrad. The background can be subtracted from under the ionisation edges, which can then be separated from each other. This is achieved by scaling Hartree-Slater calculated cross-sections to the edges in the atomic regions well above the threshold. The average scaling factors required are 1.00 for the non-metal K-edges and 1.01 for the metal L-edges (with uncertainties of a few percent). If preliminary measurements of the chromatic effects in the post-specimen lenses are correct, both drop to 0.99. The inelastic mean free path for TiC{sub 0.98} was measured as 103.6±0.5 nm compared to the prediction of 126.9 nm based on the widely used Iakoubovskii parameterisation. - Highlights: • We show how to extract absolute cross sections for EELS edges using DualEELS. • The method removes the effects of any surface layers on standards. • We use a needle specimen to determining the mean free path for inelastic scattering. • Constrained background fitting is essential to correct background subtraction. • Absolute cross sections are determined for TiC, TiN, VC and VN.

  15. STAR barrel electromagnetic calorimeter absolute calibration using 'minimum ionizing particles' from collisions at RHIC

    International Nuclear Information System (INIS)

    Cormier, T.M.; Pavlinov, A.I.; Rykov, M.V.; Rykov, V.L.; Shestermanov, K.E.

    2002-01-01

    The procedure for the STAR Barrel Electromagnetic Calorimeter (BEMC) absolute calibrations, using penetrating charged particle hits (MIP-hits) from physics events at RHIC, is presented. Its systematic and statistical errors are evaluated. It is shown that, using this technique, the equalization and transfer of the absolute scale from the test beam can be done to a percent level accuracy in a reasonable amount of time for the entire STAR BEMC. MIP-hits would also be an effective tool for continuously monitoring the variations of the BEMC tower's gains, virtually without interference to STAR's main physics program. The method does not rely on simulations for anything other than geometric and some other small corrections, and also for estimations of the systematic errors. It directly transfers measured test beam responses to operations at RHIC

  16. Absolute near-infrared refractometry with a calibrated tilted fiber Bragg grating.

    Science.gov (United States)

    Zhou, Wenjun; Mandia, David J; Barry, Seán T; Albert, Jacques

    2015-04-15

    The absolute refractive indices (RIs) of water and other liquids are determined with an uncertainty of ±0.001 at near-infrared wavelengths by using the tilted fiber Bragg grating (TFBG) cladding mode resonances of a standard single-mode fiber to measure the critical angle for total internal reflection at the interface between the fiber and its surroundings. The necessary condition to obtain absolute RIs (instead of measuring RI changes) is a thorough characterization of the dispersion of the core mode effective index of the TFBG across the full range of its cladding mode resonance spectrum. This technique is shown to be competitive with the best available measurements of the RIs of water and NaCl solutions at wavelengths in the vicinity of 1550 nm.

  17. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  18. Multiwavelength Absolute Phase Retrieval from Noisy Diffractive Patterns: Wavelength Multiplexing Algorithm

    Directory of Open Access Journals (Sweden)

    Vladimir Katkovnik

    2018-05-01

    Full Text Available We study the problem of multiwavelength absolute phase retrieval from noisy diffraction patterns. The system is lensless with multiwavelength coherent input light beams and random phase masks applied for wavefront modulation. The light beams are formed by light sources radiating all wavelengths simultaneously. A sensor equipped by a Color Filter Array (CFA is used for spectral measurement registration. The developed algorithm targeted on optimal phase retrieval from noisy observations is based on maximum likelihood technique. The algorithm is specified for Poissonian and Gaussian noise distributions. One of the key elements of the algorithm is an original sparse modeling of the multiwavelength complex-valued wavefronts based on the complex-domain block-matching 3D filtering. Presented numerical experiments are restricted to noisy Poissonian observations. They demonstrate that the developed algorithm leads to effective solutions explicitly using the sparsity for noise suppression and enabling accurate reconstruction of absolute phase of high-dynamic range.

  19. Simplified absolute phase retrieval of dual-frequency fringe patterns in fringe projection profilometry

    Science.gov (United States)

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-04-01

    In fringe projection profilometry, a simplified method is proposed to recover absolute phase maps of two-frequency fringe patterns by using a unique mapping rule. The mapping rule is designed from the rounded phase values to the fringe order of each pixel. Absolute phase can be recovered by the fringe order maps. Unlike the existing techniques, where the lowest frequency of dual- or multiple-frequency fringe patterns must be single, the presented method breaks the limitation and simplifies the procedure of phase unwrapping. Additionally, due to many issues including ambient light, shadow, sharp edges, step height boundaries and surface reflectivity variations, a novel framework of automatically identifying and removing invalid phase values is also proposed. Simulations and experiments have been carried out to validate the performances of the proposed method.

  20. Auditory working memory predicts individual differences in absolute pitch learning.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Koch, Rachelle; Nusbaum, Howard C

    2015-07-01

    Absolute pitch (AP) is typically defined as the ability to label an isolated tone as a musical note in the absence of a reference tone. At first glance the acquisition of AP note categories seems like a perceptual learning task, since individuals must assign a category label to a stimulus based on a single perceptual dimension (pitch) while ignoring other perceptual dimensions (e.g., loudness, octave, instrument). AP, however, is rarely discussed in terms of domain-general perceptual learning mechanisms. This is because AP is typically assumed to depend on a critical period of development, in which early exposure to pitches and musical labels is thought to be necessary for the development of AP precluding the possibility of adult acquisition of AP. Despite this view of AP, several previous studies have found evidence that absolute pitch category learning is, to an extent, trainable in a post-critical period adult population, even if the performance typically achieved by this population is below the performance of a "true" AP possessor. The current studies attempt to understand the individual differences in learning to categorize notes using absolute pitch cues by testing a specific prediction regarding cognitive capacity related to categorization - to what extent does an individual's general auditory working memory capacity (WMC) predict the success of absolute pitch category acquisition. Since WMC has been shown to predict performance on a wide variety of other perceptual and category learning tasks, we predict that individuals with higher WMC should be better at learning absolute pitch note categories than individuals with lower WMC. Across two studies, we demonstrate that auditory WMC predicts the efficacy of learning absolute pitch note categories. These results suggest that a higher general auditory WMC might underlie the formation of absolute pitch categories for post-critical period adults. Implications for understanding the mechanisms that underlie the

  1. Thresholds and noise limitations of colour vision in dim light.

    Science.gov (United States)

    Kelber, Almut; Yovanovich, Carola; Olsson, Peter

    2017-04-05

    Colour discrimination is based on opponent photoreceptor interactions, and limited by receptor noise. In dim light, photon shot noise impairs colour vision, and in vertebrates, the absolute threshold of colour vision is set by dark noise in cones. Nocturnal insects (e.g. moths and nocturnal bees) and vertebrates lacking rods (geckos) have adaptations to reduce receptor noise and use chromatic vision even in very dim light. In contrast, vertebrates with duplex retinae use colour-blind rod vision when noisy cone signals become unreliable, and their transition from cone- to rod-based vision is marked by the Purkinje shift. Rod-cone interactions have not been shown to improve colour vision in dim light, but may contribute to colour vision in mesopic light intensities. Frogs and toads that have two types of rods use opponent signals from these rods to control phototaxis even at their visual threshold. However, for tasks such as prey or mate choice, their colour discrimination abilities fail at brighter light intensities, similar to other vertebrates, probably limited by the dark noise in cones.This article is part of the themed issue 'Vision in dim light'. © 2017 The Author(s).

  2. A rule based method for context sensitive threshold segmentation in SPECT using simulation

    International Nuclear Information System (INIS)

    Fleming, John S.; Alaamer, Abdulaziz S.

    1998-01-01

    Robust techniques for automatic or semi-automatic segmentation of objects in single photon emission computed tomography (SPECT) are still the subject of development. This paper describes a threshold based method which uses empirical rules derived from analysis of computer simulated images of a large number of objects. The use of simulation allowed the factors affecting the threshold which correctly segmented objects to be investigated systematically. Rules could then be derived from these data to define the threshold in any particular context. The technique operated iteratively and calculated local context sensitive thresholds along radial profiles from the centre of gravity of the object. It was evaluated in a further series of simulated objects and in human studies, and compared to the use of a global fixed threshold. The method was capable of improving accuracy of segmentation and volume assessment compared to the global threshold technique. The improvements were greater for small volumes, shapes with large surface area to volume ratio, variable surrounding activity and non-uniform distributions. The method was applied successfully to simulated objects and human studies and is considered to be a significant advance on global fixed threshold techniques. (author)

  3. Relative and absolute risk in epidemiology and health physics

    International Nuclear Information System (INIS)

    Goldsmith, R.; Peterson, H.T. Jr.

    1983-01-01

    The health risk from ionizing radiation commonly is expressed in two forms: (1) the relative risk, which is the percentage increase in natural disease rate and (2) the absolute or attributable risk which represents the difference between the natural rate and the rate associated with the agent in question. Relative risk estimates for ionizing radiation generally are higher than those expressed as the absolute risk. This raises the question of which risk estimator is the most appropriate under different conditions. The absolute risk has generally been used for radiation risk assessment, although mathematical combinations such as the arithmetic or geometric mean of both the absolute and relative risks, have also been used. Combinations of the two risk estimators are not valid because the absolute and relative risk are not independent variables. Both human epidemiologic studies and animal experimental data can be found to illustrate the functional relationship between the natural cancer risk and the risk associated with radiation. This implies that the radiation risk estimate derived from one population may not be appropriate for predictions in another population, unless it is adjusted for the difference in the natural disease incidence between the two populations

  4. Absolute Navigation Information Estimation for Micro Planetary Rovers

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2016-03-01

    Full Text Available This paper provides algorithms to estimate absolute navigation information, e.g., absolute attitude and position, by using low power, weight and volume Microelectromechanical Systems-type (MEMS sensors that are suitable for micro planetary rovers. Planetary rovers appear to be easily navigable robots due to their extreme slow speed and rotation but, unfortunately, the sensor suites available for terrestrial robots are not always available for planetary rover navigation. This makes them difficult to navigate in a completely unexplored, harsh and complex environment. Whereas the relative attitude and position can be tracked in a similar way as for ground robots, absolute navigation information, unlike in terrestrial applications, is difficult to obtain for a remote celestial body, such as Mars or the Moon. In this paper, an algorithm called the EASI algorithm (Estimation of Attitude using Sun sensor and Inclinometer is presented to estimate the absolute attitude using a MEMS-type sun sensor and inclinometer, only. Moreover, the output of the EASI algorithm is fused with MEMS gyros to produce more accurate and reliable attitude estimates. An absolute position estimation algorithm has also been presented based on these on-board sensors. Experimental results demonstrate the viability of the proposed algorithms and the sensor suite for low-cost and low-weight micro planetary rovers.

  5. A numerical study of threshold states

    International Nuclear Information System (INIS)

    Ata, M.S.; Grama, C.; Grama, N.; Hategan, C.

    1979-01-01

    There are some experimental evidences of charged particle threshold states. On the statistical background of levels, some simple structures were observed in excitation spectrum. They occur near the coulombian threshold and have a large reduced width for the decay in the threshold channel. These states were identified as charged cluster threshold states. Such threshold states were observed in sup(15,16,17,18)O, sup(18,19)F, sup(19,20)Ne, sup(24)Mg, sup(32)S. The types of clusters involved were d, t, 3 He, α and even 12 C. They were observed in heavy-ions transfer reactions in the residual nucleus as strong excited levels. The charged particle threshold states occur as simple structures at high excitation energy. They could be interesting both from nuclear structure as well as nuclear reaction mechanism point of view. They could be excited as simple structures both in compound and residual nucleus. (author)

  6. Iran: the next nuclear threshold state?

    OpenAIRE

    Maurer, Christopher L.

    2014-01-01

    Approved for public release; distribution is unlimited A nuclear threshold state is one that could quickly operationalize its peaceful nuclear program into one capable of producing a nuclear weapon. This thesis compares two known threshold states, Japan and Brazil, with Iran to determine if the Islamic Republic could also be labeled a threshold state. Furthermore, it highlights the implications such a status could have on U.S. nonproliferation policy. Although Iran's nuclear program is mir...

  7. Dynamical thresholds for complete fusion

    International Nuclear Information System (INIS)

    Davies, K.T.R.; Sierk, A.J.; Nix, J.R.

    1983-01-01

    It is our purpose here to study the effect of nuclear dissipation and shape parametrization on dynamical thresholds for compound-nucleus formation in symmetric heavy-ion reactions. This is done by solving numerically classical equations of motion for head-on collisions to determine whether the dynamical trajectory in a multidimensional deformation space passes inside the fission saddle point and forms a compound nucleus, or whether it passes outside the fission saddle point and reseparates in a fast-fission or deep-inelastic reaction. Specifying the nuclear shape in terms of smoothly joined portions of three quadratic surfaces of revolution, we take into account three symmetric deformation coordinates. However, in some cases we reduce the number of coordinates to two by requiring the ends of the fusing system to be spherical in shape. The nuclear potential energy of deformation is determined in terms of a Coulomb energy and a double volume energy of a Yukawa-plus-exponential folding function. The collective kinetic energy is calculated for incompressible, nearly irrotational flow by means of the Werner-Wheeler approximation. Four possibilities are studied for the transfer of collective kinetic energy into internal single-particle excitation energy: zero dissipation, ordinary two body viscosity, one-body wall-formula dissipation, and one-body wall-and-window dissipation

  8. Absolute 22Na radioactivity measurement by gamma efficiency variation of 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Hino, Yoshio; Kawada, Yasusi.

    1994-01-01

    The absolute radioactivity of 22 Na was obtained by gamma efficiency variation of 4πβ-γ coincidence method. Some other previous techniques, such as sum peak gate method based on the positron emission rate, relative measurement with calibrated ionization chambers, and gamma spectrometry with a HPGe detector, were also tried to ensure the present result. The results of these methods were in reasonable agreement with the present absolute measurement. The assayed source solution of this experiment was transferred to NBS type ampoules, and sealed ampoules were sent to the SIR (International Reference System) in BIPM, Taiwan and Indonesia for the international comparison. (author)

  9. Determination of the absolute efficiency of an organic scintillator for neutrons with energies between 0.5 and 800 MeV

    International Nuclear Information System (INIS)

    Howe, S.D.; Lisowski, P.W.; Russell, G.J.; King, N.S.P.; Donnert, H.J.

    1984-01-01

    We have determined the absolute efficiency of an NE-213 scintillator for neutrons with energies from 0.5 to 800 MeV. The detector was 5.1 cm in diameter and 2.5 cm deep. The efficiencies were obtained for detector thresholds of 0.011, 0.48, 1.12, and 4.48 MeVee. Our results are compared to predictions of the STANTON computer code. (orig.)

  10. Perceiving pitch absolutely: Comparing absolute and relative pitch possessors in a pitch memory task

    Directory of Open Access Journals (Sweden)

    Schlaug Gottfried

    2009-08-01

    Full Text Available Abstract Background The perceptual-cognitive mechanisms and neural correlates of Absolute Pitch (AP are not fully understood. The aim of this fMRI study was to examine the neural network underlying AP using a pitch memory experiment and contrasting two groups of musicians with each other, those that have AP and those that do not. Results We found a common activation pattern for both groups that included the superior temporal gyrus (STG extending into the adjacent superior temporal sulcus (STS, the inferior parietal lobule (IPL extending into the adjacent intraparietal sulcus (IPS, the posterior part of the inferior frontal gyrus (IFG, the pre-supplementary motor area (pre-SMA, and superior lateral cerebellar regions. Significant between-group differences were seen in the left STS during the early encoding phase of the pitch memory task (more activation in AP musicians and in the right superior parietal lobule (SPL/intraparietal sulcus (IPS during the early perceptual phase (ITP 0–3 and later working memory/multimodal encoding phase of the pitch memory task (more activation in non-AP musicians. Non-significant between-group trends were seen in the posterior IFG (more in AP musicians and the IPL (more anterior activations in the non-AP group and more posterior activations in the AP group. Conclusion Since the increased activation of the left STS in AP musicians was observed during the early perceptual encoding phase and since the STS has been shown to be involved in categorization tasks, its activation might suggest that AP musicians involve categorization regions in tonal tasks. The increased activation of the right SPL/IPS in non-AP musicians indicates either an increased use of regions that are part of a tonal working memory (WM network, or the use of a multimodal encoding strategy such as the utilization of a visual-spatial mapping scheme (i.e., imagining notes on a staff or using a spatial coding for their relative pitch height for pitch

  11. Absolute marine gravimetry with matter-wave interferometry.

    Science.gov (United States)

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.

  12. Techniques in polarization physics

    International Nuclear Information System (INIS)

    Clausnitzer, G.

    1974-01-01

    A review of the current status of the technical tools necessary to perform different kinds of polarization experiments is presented, and the absolute and relative accuracy with which data can be obtained is discussed. A description of polarized targets and sources of polarized fast neutrons is included. Applications of polarization techniques to other fields is mentioned briefly. (14 figures, 3 tables, 110 references) (U.S.)

  13. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Science.gov (United States)

    van Zon, Sander K R; Bültmann, Ute; Mendes de Leon, Carlos F; Reijneveld, Sijmen A

    2015-01-01

    The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender. The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender. Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups. Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and health outcome

  14. Fatigue 󈨛. Papers presented at the International Conference on Fatigue and Fatigue Threshold (3rd) Held in Charlottesville, Virginia on June 28-July 3, 1987. Volume 2.

    Science.gov (United States)

    1987-10-15

    Behavior - HEINRICH KEMPER, BRIGITTE WEISS AND ROLAND STICKLER Absolute Fatigue Thresholds in Metallic 801 Materials - J.A. LEWIS Thermometrical ...concepts are very closed, and that the threshold dependence on R ratio results from closure. Similar observations were made Blom (5) for 2024 aluminium ...Ti-8A1-IMo-1V alloy, and type 303 stainless steel as well as aluminium alloys 7005-T591 and 5083-H321. Coincidental relationships were noted between

  15. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  16. Absolute transition probabilities for 559 strong lines of neutral cerium

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J, E-mail: jjcurry@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)

    2009-07-07

    Absolute radiative transition probabilities are reported for 559 strong lines of neutral cerium covering the wavelength range 340-880 nm. These transition probabilities are obtained by scaling published relative line intensities (Meggers et al 1975 Tables of Spectral Line Intensities (National Bureau of Standards Monograph 145)) with a smaller set of published absolute transition probabilities (Bisson et al 1991 J. Opt. Soc. Am. B 8 1545). All 559 new values are for lines for which transition probabilities have not previously been available. The estimated relative random uncertainty of the new data is +-35% for nearly all lines.

  17. Strongly nonlinear theory of rapid solidification near absolute stability

    Science.gov (United States)

    Kowal, Katarzyna N.; Altieri, Anthony L.; Davis, Stephen H.

    2017-10-01

    We investigate the nonlinear evolution of the morphological deformation of a solid-liquid interface of a binary melt under rapid solidification conditions near two absolute stability limits. The first of these involves the complete stabilization of the system to cellular instabilities as a result of large enough surface energy. We derive nonlinear evolution equations in several limits in this scenario and investigate the effect of interfacial disequilibrium on the nonlinear deformations that arise. In contrast to the morphological stability problem in equilibrium, in which only cellular instabilities appear and only one absolute stability boundary exists, in disequilibrium the system is prone to oscillatory instabilities and a second absolute stability boundary involving attachment kinetics arises. Large enough attachment kinetics stabilize the oscillatory instabilities. We derive a nonlinear evolution equation to describe the nonlinear development of the solid-liquid interface near this oscillatory absolute stability limit. We find that strong asymmetries develop with time. For uniform oscillations, the evolution equation for the interface reduces to the simple form f''+(βf')2+f =0 , where β is the disequilibrium parameter. Lastly, we investigate a distinguished limit near both absolute stability limits in which the system is prone to both cellular and oscillatory instabilities and derive a nonlinear evolution equation that captures the nonlinear deformations in this limit. Common to all these scenarios is the emergence of larger asymmetries in the resulting shapes of the solid-liquid interface with greater departures from equilibrium and larger morphological numbers. The disturbances additionally sharpen near the oscillatory absolute stability boundary, where the interface becomes deep-rooted. The oscillations are time-periodic only for small-enough initial amplitudes and their frequency depends on a single combination of physical parameters, including the

  18. A note on unique solvability of the absolute value equation

    Directory of Open Access Journals (Sweden)

    Taher Lotfi

    2014-05-01

    Full Text Available It is proved that applying sufficient regularity conditions to the interval matrix $[A-|B|,A+|B|]$‎, ‎we can create a new unique solvability condition for the absolute value equation $Ax+B|x|=b$‎, ‎since regularity of interval matrices implies unique solvability of their corresponding absolute value equation‎. ‎This condition is formulated in terms of positive definiteness of a certain point matrix‎. ‎Special case $B=-I$ is verified too as an application.

  19. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron

    2014-01-01

    numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model...... is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken...

  20. The bolometric, infrared and visual absolute magnitudes of Mira variables

    International Nuclear Information System (INIS)

    Robertson, B.S.C.; Feast, M.W.

    1981-01-01

    Statistical parallaxes, as well as stars with individually known distances are used to derive bolometric and infrared absolute magnitudes of Mira (Me) variables. The derived bolometric magnitudes are in the mean about 0.75 mag fainter than recent estimates. The problem of determining the pulsation constant is discussed. Miras with periods greater than 150 days probably pulsate in the first overtone. Those of shorter periods are anomalous and may be fundamental pulsators. It is shown that the absolute visual magnitudes at mean light of Miras with individually determined distances are consistent with values derived by Clayton and Feast from statistical parallaxes. (author)

  1. MOS Current Mode Logic Near Threshold Circuits

    Directory of Open Access Journals (Sweden)

    Alexander Shapiro

    2014-06-01

    Full Text Available Near threshold circuits (NTC are an attractive and promising technology that provides significant power savings with some delay penalty. The combination of NTC technology with MOS current mode logic (MCML is examined in this work. By combining MCML with NTC, the constant power consumption of MCML is reduced to leakage power levels that can be tolerated in certain modern applications. Additionally, the speed of NTC is improved due to the high speed nature of MCML technology. A 14 nm Fin field effect transistor (FinFET technology is used to evaluate these combined circuit techniques. A 32-bit Kogge Stone adder is chosen as a demonstration vehicle for feasibility analysis. MCML with NTC is shown to yield enhanced power efficiency when operated above 1 GHz with a 100% activity factor as compared to standard CMOS. MCML with NTC is more power efficient than standard CMOS beyond 9 GHz over a wide range of activity factors. MCML with NTC also exhibits significantly lower noise levels as compared to standard CMOS. The results of the analysis demonstrate that pairing NTC and MCML is efficient when operating at high frequencies and activity factors.

  2. Modelling the regulatory system for diabetes mellitus with a threshold window

    Science.gov (United States)

    Yang, Jin; Tang, Sanyi; Cheke, Robert A.

    2015-05-01

    Piecewise (or non-smooth) glucose-insulin models with threshold windows for type 1 and type 2 diabetes mellitus are proposed and analyzed with a view to improving understanding of the glucose-insulin regulatory system. For glucose-insulin models with a single threshold, the existence and stability of regular, virtual, pseudo-equilibria and tangent points are addressed. Then the relations between regular equilibria and a pseudo-equilibrium are studied. Furthermore, the sufficient and necessary conditions for the global stability of regular equilibria and the pseudo-equilibrium are provided by using qualitative analysis techniques of non-smooth Filippov dynamic systems. Sliding bifurcations related to boundary node bifurcations were investigated with theoretical and numerical techniques, and insulin clinical therapies are discussed. For glucose-insulin models with a threshold window, the effects of glucose thresholds or the widths of threshold windows on the durations of insulin therapy and glucose infusion were addressed. The duration of the effects of an insulin injection is sensitive to the variation of thresholds. Our results indicate that blood glucose level can be maintained within a normal range using piecewise glucose-insulin models with a single threshold or a threshold window. Moreover, our findings suggest that it is critical to individualise insulin therapy for each patient separately, based on initial blood glucose levels.

  3. Global change and the measurement of absolute sea-level

    Science.gov (United States)

    Diamante, John M.; Pyle, Thomas E.; Carter, William E.; Scherer, Wolfgang

    To quantify properly the long-term response of sea-level to climate change, land motions must be separated from the apparent or relative sea-level change recorded by conventional tide/sea-level gauges. Here we present a concept for global measurement of the true or “absolute” sea-level change, which combines recent advances in space-based geodetic techniques with plans for a global sea-level network under the World Climate Research Programme (WCRP). Data from initial feasibility tests show that land motion, due to global (plate tectonic), regional (glacial rebound), or local (fluid withdrawal) effects, can probably be measured to ±1cm (on a single measurement basis) by an innovative combination of Very Long Baseline Interferometry (VLBI) and Global Positioning System (GPS) tevhniques. By making repeated observations of position at a number of tide gauges using portable, economical GPS receivers in a differential mode relative to the fewer, more stable, but more expensive VLBI observatories, it will be possible to subtract land motion from the relative sea-level signal. Decadal to century scale trends at the 1-2mm y -1 level will be resolvable in the sea-level and vertical land motion time series within about a decade. Detection of subsidence or uplift at specific gauges will allow correction for land motion or deletion of bad data when computing regional or global, i.e. eustatic, sea-level changes. In addition to their applications in oceanography and climate studies, such data will test models by Peltier and other that relate mantle viscosity and deglaciation history to present rates of crustal subsidence or uplift. If the predicted crustal motions are confirmed, we can also have more confidence in the use of historical tide/sea-level gauge records in retrospective studies of sea-level change related to climate variability on decadal or longer time scales. It is concluded that as few as one-third (about 100) of the total number of tide/sea-level gauges (250

  4. Influence of microstructure on laser damage threshold of IBS coatings

    International Nuclear Information System (INIS)

    Stolz, C.J.; Genin, F.Y.; Kozlowski, M.R.; Long, D.; Lalazari, R.; Wu, Z.L.; Kuo, P.K.

    1996-01-01

    Ion-beam sputtering (IBS) coatings were developed for the laser gyro industry to meet significantly different requirements than those of fusion lasers. Laser gyro mirrors are small ( 26 J/cm 2 at 1,064 nm with 3-ns pulses). As part of the National Ignition Facility (NIF) coating development effort, IBS coatings are being studied to explore the possible benefits of this technology to NIF optics. As an initial step to achieving the NIF size and damage threshold requirements, the coating process is being scaled to uniformly coat a 20 x 40 cm 2 area with reduced spectral, reflected wavefront, and laser damage threshold requirements. Here, multilayer coatings deposited by ion-beam sputtering with amorphous layers were found to have lower damage thresholds at 1,064 nm than similar coatings with crystalline layers. Interestingly, at higher fluences the damage was less severe for the amorphous coatings. The magnitude of the difference in damage thresholds between the two different microstructures was strongly influenced by the size of the tested area. To better understand the microstructure effects, single layers of HfO 2 with different microstructures were studied using transmission electron microscopy, ellipsometry, and a photothermal deflection technique. Since the laser damage initiated at defects, the influence of thermal diffusivity on thermal gradients in nodular defects is also presented

  5. The problem of the detection threshold in radiation measurement

    International Nuclear Information System (INIS)

    Rose, E.; Wueneke, C.D.

    1983-01-01

    In all cases encountered in practical radiation measurement, the basic problem is to differentiate between the lowest measured value and the zero value (background, natural background radiation, etc.). For this purpose, on the mathematical side, tests based on hypotheses are to be applied. These will show the probability of differentiation between two values having the same random spread. By means of these tests and the corresponding error theory, a uniform treatment of the subject, applicable to all problems relating to measuring technique alike, can be found. Two basic concepts are found in this process, which have to be defined in terms of semantics and nomenclature: Decision threshold and detection threshold, or 'minimum detectable mean value'. At the decision threshold, one has to decide (with a given statistical error probability) whether a measured value is to be attributed to the background radiation, accepting the zero hypothesis, or whether this value differs significantly from the background radiation (error of 1rst kind). The minimum detectable mean value is the value which, with a given decision threshold, can be determined with sufficient significance to be a measured value and thus cannot be mistaken as background radiation (alternative hypothesis, error of 2nd kind). Normally, the two error types are of equal importance. It may happen, however, that one type of error gains more importance, depending on the approach. (orig.) [de

  6. Proton spectroscopic imaging of polyacrylamide gel dosimeters for absolute radiation dosimetry

    International Nuclear Information System (INIS)

    Murphy, P.S.; Schwarz, A.J.; Leach, M.O.

    2000-01-01

    Proton spectroscopy has been evaluated as a method for quantifying radiation induced changes in polyacrylamide gel dosimeters. A calibration was first performed using BANG-type gel samples receiving uniform doses of 6 MV photons from 0 to 9 Gy in 1 Gy intervals. The peak integral of the acrylic protons belonging to acrylamide and methylenebisacrylamide normalized to the water signal was plotted against absorbed dose. Response was approximately linear within the range 0-7 Gy. A large gel phantom irradiated with three, coplanar 3x3cm square fields to 5.74 Gy at isocentre was then imaged with an echo-filter technique to map the distribution of monomers directly. The image, normalized to the water signal, was converted into an absolute dose map. At the isocentre the measured dose was 5.69 Gy (SD = 0.09) which was in good agreement with the planned dose. The measured dose distribution elsewhere in the sample shows greater errors. A T 2 derived dose map demonstrated a better relative distribution but gave an overestimate of the dose at isocentre of 18%. The data indicate that MR measurements of monomer concentration can complement T 2 -based measurements and can be used to verify absolute dose. Compared with the more usual T 2 measurements for assessing gel polymerization, monomer concentration analysis is less sensitive to parameters such as gel pH and temperature, which can cause ambiguous relaxation time measurements and erroneous absolute dose calculations. (author)

  7. Accurate measurement of the optical activity of alanine crystals and the determination of their absolute chirality

    Science.gov (United States)

    Ishikawa, Kazuhiko; Terasawa, Yukana; Tanaka, Masahito; Asahi, Toru

    2017-05-01

    Wavelength dependence measurements of the chiroptical properties in alanine crystals have so far been unsuccessful using conventional spectroscopic techniques. We describe our attempts to measure the wavelength dependence of the optical activity in L- and D-alanine crystals along each crystallographic axis, and to determine the absolute chirality of alanine crystals by correlating the absolute structure to the optical activity using an x-ray diffractometer and a generalized high accuracy universal polarimeter. We have succeeded in accurately measuring the optical rotatory dispersion in the direction, which shows that the optical rotation of the D-alanine crystal is dextrorotatory and that of the L-alanine crystal is laevorotatory, thereby determining the absolute chirality. Furthermore, comparison with the optical activity in solution shows that the optical activity in alanine crystals is different not only in value, but also in the sign. These results have led us to conclude that the optical rotatory power in the crystalline state should not be simply the summation of molecular optical rotatory power values. We propose the necessity of a theory, which contains the contribution of molecular interactions within the crystal, in order to calculate the optical rotatory power of the crystalline state.

  8. High-precision gravity measurements using absolute and relative gravimeters at Mount Etna (Sicily, Italy

    Directory of Open Access Journals (Sweden)

    Ciro Del Negro

    2011-12-01

    Full Text Available Accurate detection of time gravity changes attributable to the dynamics of volcanoes requires high-precision gravity measurements. With the aim of improving the quality of data from the Mount Etna gravity network, we used both absolute and relative gravimeters in a hybrid method. In this report, some of the techniques for gravity surveys are reviewed, and the results related to each method are compared. We show how the total uncertainty estimated for the gravity measurements performed with this combined use of absolute and relative gravimeters is roughly comparable to that calculated when the measurements are acquired using only relative gravimeters (the traditional method. However, the data highlight how the hybrid approach improves the measurement capabilities for surveying the Mount Etna volcanic area. This approach enhances the accuracy of the data, and then of the four-dimensional surveying, which minimizes ambiguities inherent in the gravity measurements. As a case study, we refer to two gravity datasets acquired in 2005 and 2010 from the western part of the Etna volcano, which included five absolute and 13 relative stations of the Etna gravity network.

  9. Absolutely nondestructive discrimination of Huoshan Dendrobium nobile species with miniature near-infrared (NIR) spectrometer engine.

    Science.gov (United States)

    Hu, Tian; Yang, Hai-Long; Tang, Qing; Zhang, Hui; Nie, Lei; Li, Lian; Wang, Jin-Feng; Liu, Dong-Ming; Jiang, Wei; Wang, Fei; Zang, Heng-Chang

    2014-10-01

    As one very precious traditional Chinese medicine (TCM), Huoshan Dendrobium has not only high price, but also significant pharmaceutical efficacy. However, different species of Huoshan Dendrobium exhibit considerable difference in pharmaceutical efficacy, so rapid and absolutely non-destructive discrimination of Huoshan Dendrobium nobile according to different species is crucial to quality control and pharmaceutical effect. In this study, as one type of miniature near-infrared (NIR) spectrometer, MicroNIR 1700 was used for absolutely nondestructive determination of NIR spectra of 90 batches of Dendrobium from five species of differ- ent commodity grades. The samples were intact and not smashed. Soft independent modeling of class analogy (SIMCA) pattern recognition based on principal component analysis (PCA) was used to classify and recognize different species of Dendrobium samples. The results indicated that the SIMCA qualitative models established with pretreatment method of standard normal variate transformation (SNV) in the spectra range selected by Qs method had 100% recognition rates and 100% rejection rates. This study demonstrated that a rapid and absolutely non-destructive analytical technique based on MicroNIR 1700 spectrometer was developed for successful discrimination of five different species of Huoshan Dendrobium with acceptable accuracy.

  10. Bound electron nonlinearity beyond the ionization threshold

    OpenAIRE

    Wahlstrand, J. K.; Zahedpour, S.; Bahl, A.; Kolesik, M.; Milchberg, H. M.

    2018-01-01

    Although high field laser-induced ionization is a fundamental process underlying many applications, there have been no absolute measurements of the nonlinear polarizability of atoms and molecules in the presence of ionization. Such information is crucial, for example, for understanding the propagation of high intensity ultrashort pulses in matter. Here, we present absolute space- and time-resolved measurements of the ultrafast laser-driven nonlinear polarizability in argon, krypton, xenon, ni...

  11. Validation of Mean Absolute Sea Level of the North Atlantic obtained from Drifter, Altimetry and Wind Data

    Science.gov (United States)

    Maximenko, Nikolai A.

    2003-01-01

    Mean absolute sea level reflects the deviation of the Ocean surface from geoid due to the ocean currents and is an important characteristic of the dynamical state of the ocean. Values of its spatial variations (order of 1 m) are generally much smaller than deviations of the geoid shape from ellipsoid (order of 100 m) that makes the derivation of the absolute mean sea level a difficult task for gravity and satellite altimetry observations. Technique used by Niiler et al. for computation of the absolute mean sea level in the Kuroshio Extension was then developed into more general method and applied by Niiler et al. (2003b) to the global Ocean. The method is based on the consideration of balance of horizontal momentum.

  12. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    International Nuclear Information System (INIS)

    Prieto, Elena; Peñuelas, Iván; Martí-Climent, Josep M; Lecumberri, Pablo; Gómez, Marisol; Pagola, Miguel; Bilbao, Izaskun; Ecay, Margarita

    2012-01-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18 F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools. (paper)

  13. Measurement of absolute left ventricular volume by radionuclide angiography: a technical review

    International Nuclear Information System (INIS)

    Al-Khawaja, I.M.; Lahiri, Avijit; Raftery, E.B.; Medical Research Council, Harrow

    1988-01-01

    Absolute left ventricular volumes have important clinical implications in the evaluation of cardiac performance. Several invasive and noninvasive techniques have been reported, none of which can be considered ideal for this purpose. Contrast angiography, echocardiography and radionuclide ventriculography are open to criticism. Different radioisotopic approaches are described with emphasis on the importance of accurate separation of left ventricular activity, the selection of background activity, and the correction for photon attenuation by body tissues. Improper use of statistics and validation techniques have obscured the value of these techniques. In the absence of a 'gold standard' there should be a 'radioisotopic' left ventricular volume with established independent characteristics, repeatability and reproducibility by which new approaches can be judged. (author)

  14. Application of principal component analysis and information fusion technique to detect hotspots in NOAA/AVHRR images of Jharia coalfield, India - article no. 013523

    Energy Technology Data Exchange (ETDEWEB)

    Gautam, R.S.; Singh, D.; Mittal, A. [Indian Institute of Technology Roorkee, Roorkee (India)

    2007-07-01

    Present paper proposes an algorithm for hotspot (sub-surface fire) detection in NOAA/AVHRR images in Jharia region of India by employing Principal Component Analysis (PCA) and fusion technique. Proposed technique is very simple to implement and is more adaptive in comparison to thresholding, multi-thresholding and contextual algorithms. The algorithm takes into account the information of AVHRR channels 1, 2, 3, 4 and vegetation indices NDVI and MSAVI for the required purpose. Proposed technique consists of three steps: (1) detection and removal of cloud and water pixels from preprocessed AVHRR image and screening out the noise of channel 3, (2) application of PCA on multi-channel information along with vegetation index information of NOAA/AVHRR image to obtain principal components, and (3) fusion of information obtained from principal component 1 and 2 to classify image pixels as hotspots. Image processing techniques are applied to fuse information in first two principal component images and no absolute threshold is incorporated to specify whether particular pixel belongs to hotspot class or not, hence, proposed method is adaptive in nature and works successfully for most of the AVHRR images with average 87.27% detection accuracy and 0.201% false alarm rate while comparing with ground truth points in Jharia region of India.

  15. An Automatic Multilevel Image Thresholding Using Relative Entropy and Meta-Heuristic Algorithms

    Directory of Open Access Journals (Sweden)

    Josue R. Cuevas

    2013-06-01

    Full Text Available Multilevel thresholding has been long considered as one of the most popular techniques for image segmentation. Multilevel thresholding outputs a gray scale image in which more details from the original picture can be kept, while binary thresholding can only analyze the image in two colors, usually black and white. However, two major existing problems with the multilevel thresholding technique are: it is a time consuming approach, i.e., finding appropriate threshold values could take an exceptionally long computation time; and defining a proper number of thresholds or levels that will keep most of the relevant details from the original image is a difficult task. In this study a new evaluation function based on the Kullback-Leibler information distance, also known as relative entropy, is proposed. The property of this new function can help determine the number of thresholds automatically. To offset the expensive computational effort by traditional exhaustive search methods, this study establishes a procedure that combines the relative entropy and meta-heuristics. From the experiments performed in this study, the proposed procedure not only provides good segmentation results when compared with a well known technique such as Otsu’s method, but also constitutes a very efficient approach.

  16. Log canonical thresholds of smooth Fano threefolds

    International Nuclear Information System (INIS)

    Cheltsov, Ivan A; Shramov, Konstantin A

    2008-01-01

    The complex singularity exponent is a local invariant of a holomorphic function determined by the integrability of fractional powers of the function. The log canonical thresholds of effective Q-divisors on normal algebraic varieties are algebraic counterparts of complex singularity exponents. For a Fano variety, these invariants have global analogues. In the former case, it is the so-called α-invariant of Tian; in the latter case, it is the global log canonical threshold of the Fano variety, which is the infimum of log canonical thresholds of all effective Q-divisors numerically equivalent to the anticanonical divisor. An appendix to this paper contains a proof that the global log canonical threshold of a smooth Fano variety coincides with its α-invariant of Tian. The purpose of the paper is to compute the global log canonical thresholds of smooth Fano threefolds (altogether, there are 105 deformation families of such threefolds). The global log canonical thresholds are computed for every smooth threefold in 64 deformation families, and the global log canonical thresholds are computed for a general threefold in 20 deformation families. Some bounds for the global log canonical thresholds are computed for 14 deformation families. Appendix A is due to J.-P. Demailly.

  17. Thresholding magnetic resonance images of human brain

    Institute of Scientific and Technical Information of China (English)

    Qing-mao HU; Wieslaw L NOWINSKI

    2005-01-01

    In this paper, methods are proposed and validated to determine low and high thresholds to segment out gray matter and white matter for MR images of different pulse sequences of human brain. First, a two-dimensional reference image is determined to represent the intensity characteristics of the original three-dimensional data. Then a region of interest of the reference image is determined where brain tissues are present. The non-supervised fuzzy c-means clustering is employed to determine: the threshold for obtaining head mask, the low threshold for T2-weighted and PD-weighted images, and the high threshold for T1-weighted, SPGR and FLAIR images. Supervised range-constrained thresholding is employed to determine the low threshold for T1-weighted, SPGR and FLAIR images. Thresholding based on pairs of boundary pixels is proposed to determine the high threshold for T2- and PD-weighted images. Quantification against public data sets with various noise and inhomogeneity levels shows that the proposed methods can yield segmentation robust to noise and intensity inhomogeneity. Qualitatively the proposed methods work well with real clinical data.

  18. Time-efficient multidimensional threshold tracking method

    DEFF Research Database (Denmark)

    Fereczkowski, Michal; Kowalewski, Borys; Dau, Torsten

    2015-01-01

    Traditionally, adaptive methods have been used to reduce the time it takes to estimate psychoacoustic thresholds. However, even with adaptive methods, there are many cases where the testing time is too long to be clinically feasible, particularly when estimating thresholds as a function of anothe...

  19. 40 CFR 68.115 - Threshold determination.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Regulated Substances for Accidental Release Prevention... process exceeds the threshold. (b) For the purposes of determining whether more than a threshold quantity... portion of the process is less than 10 millimeters of mercury (mm Hg), the amount of the substance in the...

  20. Applying Threshold Concepts to Finance Education

    Science.gov (United States)

    Hoadley, Susan; Wood, Leigh N.; Tickle, Leonie; Kyng, Tim

    2016-01-01

    Purpose: The purpose of this paper is to investigate and identify threshold concepts that are the essential conceptual content of finance programmes. Design/Methodology/Approach: Conducted in three stages with finance academics and students, the study uses threshold concepts as both a theoretical framework and a research methodology. Findings: The…

  1. LHCb: A novel method for an absolute luminosity measurement at LHCb using beam-gas imaging

    CERN Multimedia

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used van der Meer scan method (VDM). This poster presents the principles of the Beam Gas Imaging method used to measure the beam overlap integral. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch.

  2. Absolute measurements of the alpha-gamma emitters activities by a sum-coincidence method

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1982-01-01

    The absolute activity of U-235 contained in a UO 2 sample, using a sum-coincidence circuit which selected only the alpha particles which were simultaneous with the well known 184 Kev gamma radiation from Th-231. The alpha particles were detected by ZnS(Ag) scintillator specially designed to show its maximun efficiency for U-235 alpha particles, whereas the gamma radiation was detected by NaI(Tl) scintillation detector. The values obtained for the half-life of U-235 was compared with data from various observers using different experimental techniques. (Author) [pt

  3. One idea of portfolio risk control for absolute return strategy risk adjustments by signals from correlation behavior

    Science.gov (United States)

    Nishiyama, N.

    2001-12-01

    Absolute return strategy provided from fund of funds (FOFs) investment schemes is the focus in Japanese Financial Community. FOFs investment mainly consists of hedge fund investment and it has two major characteristics which are low correlation against benchmark index and little impact from various external changes in the environment given maximizing return. According to the historical track record of survival hedge funds in this business world, they maintain a stable high return and low risk. However, one must keep in mind that low risk would not be equal to risk free. The failure of Long-term capital management (LTCM) that took place in the summer of 1998 was a symbolized phenomenon. The summer of 1998 exhibited a certain limitation of traditional value at risk (VaR) and some possibility that traditional VaR could be ineffectual to the nonlinear type of fluctuation in the market. In this paper, I try to bring self-organized criticality (SOC) into portfolio risk control. SOC would be well known as a model of decay in the natural world. I analyzed nonlinear type of fluctuation in the market as SOC and applied SOC to capture complicated market movement using threshold point of SOC and risk adjustments by scenario correlation as implicit signals. Threshold becomes the control parameter of risk exposure to set downside floor and forecast extreme nonlinear type of fluctuation under a certain probability. Simulation results would show synergy effect of portfolio risk control between SOC and absolute return strategy.

  4. Summary of DOE threshold limits efforts

    International Nuclear Information System (INIS)

    Wickham, L.E.; Smith, C.F.; Cohen, J.J.

    1987-01-01

    The Department of Energy (DOE) has been developing the concept of threshold quantities for use in determining which waste materials may be disposed of as nonradioactive waste in DOE sanitary landfills. Waste above a threshold level could be managed as radioactive or mixed waste (if hazardous chemicals are present); waste below this level would be handled as sanitary waste. After extensive review of a draft threshold guidance document in 1985, a second draft threshold background document was produced in March 1986. The second draft included a preliminary cost-benefit analysis and quality assurance considerations. The review of the second draft has been completed. Final changes to be incorporated include an in-depth cost-benefit analysis of two example sites and recommendations of how to further pursue (i.e. employ) the concept of threshold quantities within the DOE. 3 references

  5. Measured and modelled absolute gravity changes in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil; Forsberg, René; Strykowski, Gabriel

    2014-01-01

    in Greenland. Theresult is compared with the initial measurements of absolute gravity (AG) change at selected GreenlandNetwork (GNET) sites.We find that observations are highly influenced by the direct attraction from the ice and ocean. Thisis especially evident in the measurements conducted at the GNET...

  6. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    Science.gov (United States)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  7. Absolute configurations of zingiberenols isolated from ginger (Zingiber officinale) rhizomes

    Science.gov (United States)

    The sesquiterpene alcohol zingiberenol, or 1,10-bisaboladien-3-ol, was isolated some time ago from ginger, Zingiber officinale, rhizomes, but its absolute configuration had not been determined. With three chiral centers present in the molecule, zingiberenol can exist in eight stereoisomeric forms. ...

  8. Fabricating the absolute fake: America in contemporary pop culture

    NARCIS (Netherlands)

    Kooijman, J.

    2008-01-01

    Onze wereld wordt gedomineerd door de Amerikaanse popcultuur. Fabricating the Absolute Fake onderzoekt de dynamiek van Amerikanisering aan de hand van hedendaagse films, televisieprogramma's en popsterren die reflecteren op de vraag wat het betekent om Amerikaan in een mondiale popcultuur te zijn.

  9. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.

    2011-04-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional support for our model of enantioinduction in the palladium(II)-catalyzed oxidative kinetic resolution of secondary alcohols. © 2010 Elsevier Ltd. All rights reserved.

  10. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  11. The Absolute and the Relative Dimensions of Constitutional Rights

    Czech Academy of Sciences Publication Activity Database

    Alexy, Robert

    2017-01-01

    Roč. 37, č. 1 (2017), s. 31-47 ISSN 0143-6503 Keywords : constitutional rights * judicial review * proportionality Subject RIV: AG - Legal Sciences OBOR OECD: Law Impact factor: 1.242, year: 2016 https://academic.oup.com/ojls/article/37/1/31/2669583/The-Absolute-and-the-Relative-Dimensions-of

  12. Absolute configuration of some dinorlabdanes from the copaiba oil

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Adriano L.; Baptistela, Lucia H.B.; Imamura, Paulo M. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Inst. de Quimica], e-mail: imam@iqm.unicamp.br

    2009-07-01

    A novel ent-dinorlabdane ({iota})-13(R)-14,15-dinorlabd-8(17)-ene-3,13-diol was isolated from commercial copaiba oil along with two known dinorlabdanes. The absolute configuration of these dinorditerpenes was established for the first time through synthesis starting from known ({iota})-3-hydroxycopalic acid, which was also isolated from the same oleoresin. (author)

  13. Absolute Risk Aversion and the Returns to Education.

    Science.gov (United States)

    Brunello, Giorgio

    2002-01-01

    Uses 1995 Italian household income and wealth survey to measure individual absolute risk aversion of 1,583 married Italian male household heads. Uses this measure as an instrument for attained education in a standard-log earnings equation. Finds that the IV estimate of the marginal return to schooling is much higher than the ordinary least squares…

  14. Absolute differential yield of parametric x-ray radiation

    International Nuclear Information System (INIS)

    Shchagin, A.V.; Pristupa, V.I.; Khizhnyak, N.A.

    1993-01-01

    The results of measurements of absolute differential yield of parametric X-ray radiation (PXR) in thin single crystal are presented for the first time. It has been established that the experimental results are in good agreement with theoretical calculations according with kinematical theory. The influence of density effect on PXR properties is discussed. (author). 19 refs., 7 figs

  15. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    NARCIS (Netherlands)

    Hernandez, E. M.; Juarez, A. M.; Kilcoyne, A. L. D.; Aguilar, A.; Hernandez, L.; Antillon, A.; Macaluso, D.; Morales-Mori, A.; Gonzalez-Magana, O.; Hanstorp, D.; Covington, A. M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    The photoionization of Cl+ leading to Cl2+ was measured in the photon energy range of 19.5-28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl+ ion beam with a photon beam of

  16. Comments on the theory of absolute and convective instabilities

    International Nuclear Information System (INIS)

    Oscarsson, T.E.; Roennmark, K.

    1986-10-01

    The theory of absolute and convective instabilities is discussed and we argue that the basis of the theory is questionable, since it describes the linear development of instabilities by their behaviour in the time asymptotic limit. In order to make sensible predictions on the linear development of instabilities, the problem should be studied on the finite time scale implied by the linear approximation. (authors)

  17. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2017-01-01

    The widely applied “dollar-a-day” methodology identifies global absolute poverty as declining precipitously since the early 80’s throughout the developing world. The methodological underpinnings of the “dollar-a-day” approach have been questioned in terms of adequately representing equivalent

  18. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2015-01-01

    The global absolute poverty rates of the World Bank demonstrate a continued decline of poverty in developing countries between 1983 and 2012. However, the methodology applied to derive these results has received extensive criticism by scholars for requiring the application of PPP exchange rates and

  19. Population-based absolute risk estimation with survey data

    Science.gov (United States)

    Kovalchik, Stephanie A.; Pfeiffer, Ruth M.

    2013-01-01

    Absolute risk is the probability that a cause-specific event occurs in a given time interval in the presence of competing events. We present methods to estimate population-based absolute risk from a complex survey cohort that can accommodate multiple exposure-specific competing risks. The hazard function for each event type consists of an individualized relative risk multiplied by a baseline hazard function, which is modeled nonparametrically or parametrically with a piecewise exponential model. An influence method is used to derive a Taylor-linearized variance estimate for the absolute risk estimates. We introduce novel measures of the cause-specific influences that can guide modeling choices for the competing event components of the model. To illustrate our methodology, we build and validate cause-specific absolute risk models for cardiovascular and cancer deaths using data from the National Health and Nutrition Examination Survey. Our applications demonstrate the usefulness of survey-based risk prediction models for predicting health outcomes and quantifying the potential impact of disease prevention programs at the population level. PMID:23686614

  20. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos; Ketcheson, David I.

    2014-01-01

    -Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend

  1. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    Abstract. The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is ...

  2. Absolute parametric instability in a nonuniform plane plasma

    Indian Academy of Sciences (India)

    The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is considered.

  3. Absolute configuration and antiprotozoal activity of minquartynoic acid

    DEFF Research Database (Denmark)

    Rasmussen, H B; Christensen, Søren Brøgger; Kvist, L P

    2000-01-01

    Minquartynoic acid (1) was isolated as an antimalarial and antileishmanial constituent of the Peruvian tree Minquartia guianensis and its absolute configuration at C-17 established to be (+)-S through conversion to the known (+)-(S)-17-hydroxystearic acid (2) and confirmed using Mosher's method....

  4. Relative versus Absolute Stimulus Control in the Temporal Bisection Task

    Science.gov (United States)

    de Carvalho, Marilia Pinhiero; Machado, Armando

    2012-01-01

    When subjects learn to associate two sample durations with two comparison keys, do they learn to associate the keys with the short and long samples (relational hypothesis), or with the specific sample durations (absolute hypothesis)? We exposed 16 pigeons to an ABA design in which phases A and B corresponded to tasks using samples of 1 s and 4 s,…

  5. Absolute intensity calibration for ECE measurements on EAST

    International Nuclear Information System (INIS)

    Liu Yong; Liu Xiang; Zhao Hailin

    2014-01-01

    In this proceeding, the results of the in-situ absolute intensity calibration for ECE measurements on EAST are presented. A 32-channel heterodyne radiometer system and a Michelson interferometer on EAST have been calibrated independently, and preliminary results from plasma operation indicate a good agreement between the electron temperature profiles obtained with different systems. (author)

  6. Absolute dissipative drift-wave instabilities in tokamaks

    International Nuclear Information System (INIS)

    Chen, L.; Chance, M.S.; Cheng, C.Z.

    1979-07-01

    Contrary to previous theoretical predictions, it is shown that the dissipative drift-wave instabilities are absolute in tokamak plasmas. The existence of unstable eigenmodes is shown to be associated with a new eigenmode branch induced by the finite toroidal couplings

  7. On quantum harmonic oscillator being subjected to absolute ...

    Indian Academy of Sciences (India)

    On quantum harmonic oscillator being subjected to absolute potential state. SWAMI NITYAYOGANANDA. Ramakrishna Mission Ashrama, R.K. Beach, Visakhapatnam 530 003, India. E-mail: nityayogananda@gmail.com. MS received 1 May 2015; accepted 6 May 2016; published online 3 December 2016. Abstract.

  8. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the ∑ n ≤ N f(n)$ with explicit error term. As a corollary we obtain new results about sum-of-divisors functions and Jordan's totient functions.

  9. A Threshold Continuum for Aeolian Sand Transport

    Science.gov (United States)

    Swann, C.; Ewing, R. C.; Sherman, D. J.

    2015-12-01

    The threshold of motion for aeolian sand transport marks the initial entrainment of sand particles by the force of the wind. This is typically defined and modeled as a singular wind speed for a given grain size and is based on field and laboratory experimental data. However, the definition of threshold varies significantly between these empirical models, largely because the definition is based on visual-observations of initial grain movement. For example, in his seminal experiments, Bagnold defined threshold of motion when he observed that 100% of the bed was in motion. Others have used 50% and lesser values. Differences in threshold models, in turn, result is large errors in predicting the fluxes associated with sand and dust transport. Here we use a wind tunnel and novel sediment trap to capture the fractions of sand in creep, reptation and saltation at Earth and Mars pressures and show that the threshold of motion for aeolian sand transport is best defined as a continuum in which grains progress through stages defined by the proportion of grains in creep and saltation. We propose the use of scale dependent thresholds modeled by distinct probability distribution functions that differentiate the threshold based on micro to macro scale applications. For example, a geologic timescale application corresponds to a threshold when 100% of the bed in motion whereas a sub-second application corresponds to a threshold when a single particle is set in motion. We provide quantitative measurements (number and mode of particle movement) corresponding to visual observations, percent of bed in motion and degrees of transport intermittency for Earth and Mars. Understanding transport as a continuum provides a basis for revaluating sand transport thresholds on Earth, Mars and Titan.

  10. Probability of an Abnormal Screening PSA Result Based on Age, Race, and PSA Threshold

    Science.gov (United States)

    Espaldon, Roxanne; Kirby, Katharine A.; Fung, Kathy Z.; Hoffman, Richard M.; Powell, Adam A.; Freedland, Stephen J.; Walter, Louise C.

    2014-01-01

    Objective To determine the distribution of screening PSA values in older men and how different PSA thresholds affect the proportion of white, black, and Latino men who would have an abnormal screening result across advancing age groups. Methods We used linked national VA and Medicare data to determine the value of the first screening PSA test (ng/mL) of 327,284 men age 65+ who underwent PSA screening in the VA healthcare system in 2003. We calculated the proportion of men with an abnormal PSA result based on age, race, and common PSA thresholds. Results Among men age 65+, 8.4% had a PSA >4.0ng/mL. The percentage of men with a PSA >4.0ng/mL increased with age and was highest in black men (13.8%) versus white (8.0%) or Latino men (10.0%) (PPSA >4.0ng/mL ranged from 5.1% of Latino men age 65–69 to 27.4% of black men age 85+. Raising the PSA threshold from >4.0ng/mL to >10.0ng/mL, reclassified the greatest percentage of black men age 85+ (18.3% absolute change) and the lowest percentage of Latino men age 65–69 (4.8% absolute change) as being under the biopsy threshold (PPSA threshold together affect the pre-test probability of an abnormal screening PSA result. Based on screening PSA distributions, stopping screening among men whose PSA 10ng/ml has the greatest effect on reducing the number of older black men who will face biopsy decisions after screening. PMID:24439009

  11. Absolute Gravity Datum in the Age of Cold Atom Gravimeters

    Science.gov (United States)

    Childers, V. A.; Eckl, M. C.

    2014-12-01

    The international gravity datum is defined today by the International Gravity Standardization Net of 1971 (IGSN-71). The data supporting this network was measured in the 1950s and 60s using pendulum and spring-based gravimeter ties (plus some new ballistic absolute meters) to replace the prior protocol of referencing all gravity values to the earlier Potsdam value. Since this time, gravimeter technology has advanced significantly with the development and refinement of the FG-5 (the current standard of the industry) and again with the soon-to-be-available cold atom interferometric absolute gravimeters. This latest development is anticipated to provide improvement in the range of two orders of magnitude as compared to the measurement accuracy of technology utilized to develop ISGN-71. In this presentation, we will explore how the IGSN-71 might best be "modernized" given today's requirements and available instruments and resources. The National Geodetic Survey (NGS), along with other relevant US Government agencies, is concerned about establishing gravity control to establish and maintain high order geodetic networks as part of the nation's essential infrastructure. The need to modernize the nation's geodetic infrastructure was highlighted in "Precise Geodetic Infrastructure, National Requirements for a Shared Resource" National Academy of Science, 2010. The NGS mission, as dictated by Congress, is to establish and maintain the National Spatial Reference System, which includes gravity measurements. Absolute gravimeters measure the total gravity field directly and do not involve ties to other measurements. Periodic "intercomparisons" of multiple absolute gravimeters at reference gravity sites are used to constrain the behavior of the instruments to ensure that each would yield reasonably similar measurements of the same location (i.e. yield a sufficiently consistent datum when measured in disparate locales). New atomic interferometric gravimeters promise a significant

  12. Deep pain thresholds in the distal limbs of healthy human subjects.

    Science.gov (United States)

    Rolke, R; Andrews Campbell, K; Magerl, W; Treede, R-D

    2005-02-01

    Pressure pain thresholds (PPTs) in distal limbs have been under-investigated despite their potential clinical importance. Therefore, we compared PPTs over nail bed, bony prominences, and muscle in distal parts of upper and lower limbs. We investigated 12 healthy subjects using three handheld devices: a spring-loaded, analogue pressure threshold meter (PTM) with two operating ranges, and an electronic Algometer. PPTs were determined with three series of ascending stimulus intensities with a ramp of about 50 kPa/s. PPTs were normally distributed in logarithmic space. PPTs over different tissues varied significantly (ANOVA, pAlgometer than with PTMs (ANOVA, ptesting over muscle. There was no significant right-left difference (ANOVA, p=0.33). In spite of considerable variability across subjects, reproducibility within subjects was high (correlation coefficients>0.90). For within-subject comparisons, threshold elevations beyond 33-43% would be abnormal (95% confidence intervals), whereas only deviations from the group mean by at least a factor of two would be abnormal with respect to absolute normative values. PPTs over distal muscles were comparable to published values on proximal limb and trunk muscles. These findings suggest that pressure pain testing over distal muscles may be a sensitive test for deep pain sensitivity and that the simple and less expensive devices are sufficient for testing this tissue type. Intra-individual site-to-site comparisons will be more sensitive than absolute normative values.

  13. Automatic Multi-Level Thresholding Segmentation Based on Multi-Objective Optimization

    Directory of Open Access Journals (Sweden)

    L. DJEROU,

    2012-01-01

    Full Text Available In this paper, we present a new multi-level image thresholding technique, called Automatic Threshold based on Multi-objective Optimization "ATMO" that combines the flexibility of multi-objective fitness functions with the power of a Binary Particle Swarm Optimization algorithm "BPSO", for searching the "optimum" number of the thresholds and simultaneously the optimal thresholds of three criteria: the between-class variances criterion, the minimum error criterion and the entropy criterion. Some examples of test images are presented to compare our segmentation method, based on the multi-objective optimization approach with Otsu’s, Kapur’s and Kittler’s methods. Our experimental results show that the thresholding method based on multi-objective optimization is more efficient than the classical Otsu’s, Kapur’s and Kittler’s methods.

  14. Threshold-adaptive canny operator based on cross-zero points

    Science.gov (United States)

    Liu, Boqi; Zhang, Xiuhua; Hong, Hanyu

    2018-03-01

    Canny edge detection[1] is a technique to extract useful structural information from different vision objects and dramatically reduce the amount of data to be processed. It has been widely applied in various computer vision systems. There are two thresholds have to be settled before the edge is segregated from background. Usually, by the experience of developers, two static values are set as the thresholds[2]. In this paper, a novel automatic thresholding method is proposed. The relation between the thresholds and Cross-zero Points is analyzed, and an interpolation function is deduced to determine the thresholds. Comprehensive experimental results demonstrate the effectiveness of proposed method and advantageous for stable edge detection at changing illumination.

  15. Otsu Based Optimal Multilevel Image Thresholding Using Firefly Algorithm

    Directory of Open Access Journals (Sweden)

    N. Sri Madhava Raja

    2014-01-01

    Full Text Available Histogram based multilevel thresholding approach is proposed using Brownian distribution (BD guided firefly algorithm (FA. A bounded search technique is also presented to improve the optimization accuracy with lesser search iterations. Otsu’s between-class variance function is maximized to obtain optimal threshold level for gray scale images. The performances of the proposed algorithm are demonstrated by considering twelve benchmark images and are compared with the existing FA algorithms such as Lévy flight (LF guided FA and random operator guided FA. The performance assessment comparison between the proposed and existing firefly algorithms is carried using prevailing parameters such as objective function, standard deviation, peak-to-signal ratio (PSNR, structural similarity (SSIM index, and search time of CPU. The results show that BD guided FA provides better objective function, PSNR, and SSIM, whereas LF based FA provides faster convergence with relatively lower CPU time.

  16. A technique for the absolute measurement of activity using a gamma camera and computer

    International Nuclear Information System (INIS)

    Fleming, J.S.

    1979-01-01

    The quantity of activity of an isotope in an organ is of interest in gamma camera studies. There are problems in correcting the regional gamma camera counts for varying absorption in body tissue, particularly for thick organs. A description is given of a general method, based on anterior, posterior and lateral views. The method has been applied to liver 99 Tcsup(m) sulphur colloid imaging. Phantom measurements showed that the smallest error to be expected was 3.2%. In practice errors would be 5 to 10%, although lower errors would be associated with estimates of liver/spleen ratios. (U.K.)

  17. Absolute coronary blood flow measurement and microvascular resistance in ST-elevation myocardial infarction in the acute and subacute phase

    Energy Technology Data Exchange (ETDEWEB)

    Wijnbergen, Inge; Veer, Marcel van ' t [Department of Cardiology, Catharina Hospital, Eindhoven (Netherlands); Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven (Netherlands); Lammers, Jeroen; Ubachs, Joey [Department of Cardiology, Catharina Hospital, Eindhoven (Netherlands); Pijls, Nico H.J., E-mail: nico.pijls@cze.nl [Department of Cardiology, Catharina Hospital, Eindhoven (Netherlands); Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-03-15

    Background/Purpose: In a number of patients with acute myocardial infarction (AMI), myocardial hypoperfusion, known as the no-reflow phenomenon, persists after primary percutaneous intervention (PPCI). The aim of this study was to evaluate the feasibility and safety of a new quantitative method of measuring absolute blood flow and resistance within the perfusion bed of an infarct-related artery. Furthermore, we sought to study no-reflow by correlating these measurements to the index of microvascular resistance (IMR) and the area at risk (AR) as determined by cardiac magnetic resonance imaging (CMR). Methods: Measurements of absolute flow and myocardial resistance were performed in 20 patients with ST-segment elevation myocardial infarction (STEMI), first immediately following PPCI and then again after 3–5 days. These measurements used the technique of thermodilution during a continuous infusion of saline. Flow was expressed in ml/min per gram of tissue within the area at risk. Results: The average time needed for measurement of absolute flow, resistance and IMR was 20 min, and all measurements could be performed without complication. A higher flow supplying the AR correlated with a lower IMR in the acute phase. Absolute flow increased from 3.14 to 3.68 ml/min/g (p = 0.25) and absolute resistance decreased from 1317 to 1099 dyne.sec.cm-5/g (p = 0.40) between the first day and fifth day after STEMI. Conclusions: Measurement of absolute flow and microvascular resistance is safe and feasible in STEMI patients and may allow for a better understanding of microvascular (dys)function in the early phase of AMI. - Highlights: • We measured absolute coronary blood flow and microvascular resistance in STEMI patients in the acute phase and in the subacute phase, using the technique of thermodilution with low grade intracoronary continuous infusion of saline. • These measurements are safe and feasible during PPCI in STEMI patients. • In STEMI patients, absolute flow

  18. Reaction thresholds in doubly special relativity

    International Nuclear Information System (INIS)

    Heyman, Daniel; Major, Seth; Hinteleitner, Franz

    2004-01-01

    Two theories of special relativity with an additional invariant scale, 'doubly special relativity', are tested with calculations of particle process kinematics. Using the Judes-Visser modified conservation laws, thresholds are studied in both theories. In contrast with some linear approximations, which allow for particle processes forbidden in special relativity, both the Amelino-Camelia and Magueijo-Smolin frameworks allow no additional processes. To first order, the Amelino-Camelia framework thresholds are lowered and the Magueijo-Smolin framework thresholds may be raised or lowered

  19. Investigation of excimer laser ablation threshold of polymers using a microphone

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Joerg; Niino, Hiroyuki; Yabe, Akira

    2002-09-30

    KrF excimer laser ablation of polyethylene terephthalate (PET), polyimide (PI) and polycarbonate (PC) in air was studied by an in situ monitoring technique using a microphone. The microphone signal generated by a short acoustic pulse represented the etch rate of laser ablation depending on the laser fluence, i.e., the ablation 'strength'. From a linear relationship between the microphone output voltage and the laser fluence, the single-pulse ablation thresholds were found to be 30 mJ cm{sup -2} for PET, 37 mJ cm{sup -2} for PI and 51 mJ cm{sup -2} for PC (20-pulses threshold). The ablation thresholds of PET and PI were not influenced by the number of pulses per spot, while PC showed an incubation phenomenon. A microphone technique provides a simple method to determine the excimer laser ablation threshold of polymer films.

  20. Speech-in-Noise Tests and Supra-threshold Auditory Evoked Potentials as Metrics for Noise Damage and Clinical Trial Outcome Measures.

    Science.gov (United States)

    Le Prell, Colleen G; Brungart, Douglas S

    2016-09-01

    In humans, the accepted clinical standards for detecting hearing loss are the behavioral audiogram, based on the absolute detection threshold of pure-tones, and the threshold auditory brainstem response (ABR). The audiogram and the threshold ABR are reliable and sensitive measures of hearing thresholds in human listeners. However, recent results from noise-exposed animals demonstrate that noise exposure can cause substantial neurodegeneration in the peripheral auditory system without degrading pure-tone audiometric thresholds. It has been suggested that clinical measures of auditory performance conducted with stimuli presented above the detection threshold may be more sensitive than the behavioral audiogram in detecting early-stage noise-induced hearing loss in listeners with audiometric thresholds within normal limits. Supra-threshold speech-in-noise testing and supra-threshold ABR responses are reviewed here, given that they may be useful supplements to the behavioral audiogram for assessment of possible neurodegeneration in noise-exposed listeners. Supra-threshold tests may be useful for assessing the effects of noise on the human inner ear, and the effectiveness of interventions designed to prevent noise trauma. The current state of the science does not necessarily allow us to define a single set of best practice protocols. Nonetheless, we encourage investigators to incorporate these metrics into test batteries when feasible, with an effort to standardize procedures to the greatest extent possible as new reports emerge.

  1. The utility of absolute risk prediction using FRAX® and Garvan Fracture Risk Calculator in daily practice.

    Science.gov (United States)

    van Geel, Tineke A C M; Eisman, John A; Geusens, Piet P; van den Bergh, Joop P W; Center, Jacqueline R; Dinant, Geert-Jan

    2014-02-01

    There are two commonly used fracture risk prediction tools FRAX(®) and Garvan Fracture Risk Calculator (GARVAN-FRC). The objective of this study was to investigate the utility of these tools in daily practice. A prospective population-based 5-year follow-up study was conducted in ten general practice centres in the Netherlands. For the analyses, the FRAX(®) and GARVAN-FRC 10-year absolute risks (FRAX(®) does not have 5-year risk prediction) for all fractures were used. Among 506 postmenopausal women aged ≥60 years (mean age: 67.8±5.8 years), 48 (9.5%) sustained a fracture during follow-up. Both tools, using BMD values, distinguish between women who did and did not fracture (10.2% vs. 6.8%, respectively for FRAX(®) and 32.4% vs. 39.1%, respectively for GARVAN-FRC, pbetter for women who sustained a fracture (higher sensitivity) and FRAX(®) for women who did not sustain a fracture (higher specificity). Similar results were obtained using age related cut off points. The discriminant value of both models is at least as good as models used in other medical conditions; hence they can be used to communicate the fracture risk to patients. However, given differences in the estimated risks between FRAX(®) and GARVAN-FRC, the significance of the absolute risk must be related to country-specific recommended intervention thresholds to inform the patient. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. SART-Type Half-Threshold Filtering Approach for CT Reconstruction.

    Science.gov (United States)

    Yu, Hengyong; Wang, Ge

    2014-01-01

    The [Formula: see text] regularization problem has been widely used to solve the sparsity constrained problems. To enhance the sparsity constraint for better imaging performance, a promising direction is to use the [Formula: see text] norm (0 < p < 1) and solve the [Formula: see text] minimization problem. Very recently, Xu et al. developed an analytic solution for the [Formula: see text] regularization via an iterative thresholding operation, which is also referred to as half-threshold filtering. In this paper, we design a simultaneous algebraic reconstruction technique (SART)-type half-threshold filtering framework to solve the computed tomography (CT) reconstruction problem. In the medical imaging filed, the discrete gradient transform (DGT) is widely used to define the sparsity. However, the DGT is noninvertible and it cannot be applied to half-threshold filtering for CT reconstruction. To demonstrate the utility of the proposed SART-type half-threshold filtering framework, an emphasis of this paper is to construct a pseudoinverse transforms for DGT. The proposed algorithms are evaluated with numerical and physical phantom data sets. Our results show that the SART-type half-threshold filtering algorithms have great potential to improve the reconstructed image quality from few and noisy projections. They are complementary to the counterparts of the state-of-the-art soft-threshold filtering and hard-threshold filtering.

  3. Detecting fatigue thresholds from electromyographic signals: A systematic review on approaches and methodologies.

    Science.gov (United States)

    Ertl, Peter; Kruse, Annika; Tilp, Markus

    2016-10-01

    The aim of the current paper was to systematically review the relevant existing electromyographic threshold concepts within the literature. The electronic databases MEDLINE and SCOPUS were screened for papers published between January 1980 and April 2015 including the keywords: neuromuscular fatigue threshold, anaerobic threshold, electromyographic threshold, muscular fatigue, aerobic-anaerobictransition, ventilatory threshold, exercise testing, and cycle-ergometer. 32 articles were assessed with regard to their electromyographic methodologies, description of results, statistical analysis and test protocols. Only one article was of very good quality. 21 were of good quality and two articles were of very low quality. The review process revealed that: (i) there is consistent evidence of one or two non-linear increases of EMG that might reflect the additional recruitment of motor units (MU) or different fiber types during fatiguing cycle ergometer exercise, (ii) most studies reported no statistically significant difference between electromyographic and metabolic thresholds, (iii) one minute protocols with increments between 10 and 25W appear most appropriate to detect muscular threshold, (iv) threshold detection from the vastus medialis, vastus lateralis, and rectus femoris is recommended, and (v) there is a great variety in study protocols, measurement techniques, and data processing. Therefore, we recommend further research and standardization in the detection of EMGTs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Proposal for an absolute, atomic definition of mass

    International Nuclear Information System (INIS)

    Wignall, J.W.G.

    1991-11-01

    It is proposed that the mass of a particle be defined absolutely as its de Broglie frequency, measured as the mean de Broglie wavelength of the particle when it has a mean speed (v) and Lorentz factor γ; the masses of systems too large to have a measurable de Broglie wavelength mean are then to be derived by specifying the usual inertial and additive properties of mass. This definition avoids the use of an arbitrary macroscopic standard such as the prototype kilogram, and, if present theory is correct, does not even require the choice of a specific particle as a mass standard. Suggestions are made as to how this absolute mass can be realized and measured at the macroscopic level and, finally, some comments are made on the effect of the new definition on the form of the equations of physics. 19 refs

  5. Absolute limit on rotation of gravitationally bound stars

    Science.gov (United States)

    Glendenning, N. K.

    1994-03-01

    The authors seek an absolute limit on the rotational period for a neutron star as a function of its mass, based on the minimal constraints imposed by Einstein's theory of relativity, Le Chatelier's principle, causality, and a low-density equation of state, uncertainties which can be evaluated as to their effect on the result. This establishes a limiting curve in the mass-period plane below which no pulsar that is a neutron star can lie. For example, the minimum possible Kepler period, which is an absolute limit on rotation below which mass-shedding would occur, is 0.33 ms for a M = 1.442 solar mass neutron star (the mass of PSR1913+16). If the limit were found to be broken by any pulsar, it would signal that the confined hadronic phase of ordinary nucleons and nuclei is only metastable.

  6. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  7. ABSOLUTE AND COMPARATIVE SUSTAINABILITY OF FARMING ENTERPRISES IN BULGARIA

    Directory of Open Access Journals (Sweden)

    H. Bachev

    2017-04-01

    Full Text Available Evaluating absolute and comparative sustainability of farming enterprises is among the most topical issues for researchers, farmers, investors, administrators, politicians, interests groups and public at large. Nevertheless, in Bulgaria and most East European countries there are no comprehensive assessments on sustainability level of Bulgarian farms of different juridical type. This article applies a holistic framework and assesses absolute and comparative sustainability major farming structures in Bulgaria - unregistered farms of Natural Persons, Sole Traders, Cooperatives, and Companies. First, method of the study is outlined, and overall characteristics of surveyed farming enterprises presented. After that an assessment is made of integral, governance, economic, social, environmental sustainability of farming structures of different juridical type. Next, structure of farming enterprises with different sustainability levels is analyzed. Finally, conclusion from the study and directions for further research and amelioration of sustainability assessments suggested.

  8. Absolute dating of the Aegean Late Bronze Age

    International Nuclear Information System (INIS)

    Warren, P.M.

    1987-01-01

    A recent argument for raising the absolute date of the beginning of the Aegean Late Bronze (LB) Age to about 1700 B.C. is critically examined. It is argued here that: (1) the alabaster lid from Knossos did have the stratigraphical context assigned to it by Evans, in all probability Middle Minoan IIIA, c. 1650 B.C.; (2) the attempt to date the alabastron found in an early Eighteenth Dynasty context at Aniba to Late Minoan IIIA:1 is open to objections; (3) radiocarbon dates from Aegean LB I contexts are too wide in their calibrated ranges and too inconsistent both within and between site sets to offer any reliable grounds at present for raising Aegean LB I absolute chronology to 1700 B.C. Other evidence, however, suggests this period began about 1600 B.C., i.e. some fifty years earlier than the conventional date of 1550 B.C. (author)

  9. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  10. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  11. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  12. Synesthesia and rhythm. The road to absolute cinema

    Directory of Open Access Journals (Sweden)

    Ricardo Roncero Palomar

    2017-05-01

    Full Text Available Absolute cinema, developed during the historical avant-garde, con-tinued with a long artistic tradition that linked musical with visual experience. Due to cinema as médium of expression, this filmmakers were able to work with the moving image to develop concepts such as rhythm, also with more complex figures than the colored spots that other devices could create at those time. This study starts with the published texts in 1704 by Newton about color, and provides an overview of those artistic highlights that link image and sound, and which creates the origins of absolute cinema. The connections and equivalences between the visual and sound experiences used by these filmmakers are also studied in order to know if there was a continuous line with the origins of these studies or if there was a rupture and other later investigations were able to have more repercussion in their works.

  13. Approaching the O{sup -} photodetachment threshold with velocity-map imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cavanagh, S J; Gibson, S T; Lewis, B R, E-mail: Steven.Cavanagh@anu.edu.a, E-mail: Stephen.Gibson@anu.edu.a [Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia)

    2009-11-01

    A series of photodetachment spectra from O{sup -} has been measured from near threshold to several eV using the technique of velocity-map imaging. With a resolving power of {Delta}E/E {<=} 0.38%, the energy and angular dependences for the six fine-structure transitions have been determined. For the first time, the energy and angular dependences of the cross section within a few meV of threshold have been determined.

  14. Approach to DOE threshold guidance limits

    International Nuclear Information System (INIS)

    Shuman, R.D.; Wickham, L.E.

    1984-01-01

    The need for less restrictive criteria governing disposal of extremely low-level radioactive waste has long been recognized. The Low-Level Waste Management Program has been directed by the Department of Energy (DOE) to aid in the development of a threshold guidance limit for DOE low-level waste facilities. Project objectives are concernd with the definition of a threshold limit dose and pathway analysis of radionuclide transport within selected exposure scenarios at DOE sites. Results of the pathway analysis will be used to determine waste radionuclide concentration guidelines that meet the defined threshold limit dose. Methods of measurement and verification of concentration limits round out the project's goals. Work on defining a threshold limit dose is nearing completion. Pathway analysis of sanitary landfill operations at the Savannah River Plant and the Idaho National Engineering Laboratory is in progress using the DOSTOMAN computer code. Concentration limit calculations and determination of implementation procedures shall follow completion of the pathways work. 4 references

  15. Pion photoproduction on the nucleon at threshold

    International Nuclear Information System (INIS)

    Cheon, I.T.; Jeong, M.T.

    1989-08-01

    Electric dipole amplitudes of pion photoproduction on the nucleon at threshold have been calculated in the framework of the chiral bag model. Our results are in good agreement with the existing experimental data

  16. Effect of dissipation on dynamical fusion thresholds

    International Nuclear Information System (INIS)

    Sierk, A.J.

    1986-01-01

    The existence of dynamical thresholds to fusion in heavy nuclei (A greater than or equal to 200) due to the nature of the potential-energy surface is shown. These thresholds exist even in the absence of dissipative forces, due to the coupling between the various collective deformation degrees of freedom. Using a macroscopic model of nuclear shape dynamics, It is shown how three different suggested dissipation mechanisms increase by varying amounts the excitation energy over the one-dimensional barrier required to cause compound-nucleus formation. The recently introduced surface-plus-window dissipation may give a reasonable representation of experimental data on fusion thresholds, in addition to properly describing fission-fragment kinetic energies and isoscalar giant multipole widths. Scaling of threshold results to asymmetric systems is discussed. 48 refs., 10 figs

  17. 40 CFR 98.411 - Reporting threshold.

    Science.gov (United States)

    2010-07-01

    ...) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.411 Reporting threshold. Any supplier of industrial greenhouse gases who meets the requirements of § 98.2(a)(4) must report GHG...

  18. Melanin microcavitation threshold in the near infrared

    Science.gov (United States)

    Schmidt, Morgan S.; Kennedy, Paul K.; Vincelette, Rebecca L.; Schuster, Kurt J.; Noojin, Gary D.; Wharmby, Andrew W.; Thomas, Robert J.; Rockwell, Benjamin A.

    2014-02-01

    Thresholds for microcavitation of isolated bovine and porcine melanosomes were determined using single nanosecond (ns) laser pulses in the NIR (1000 - 1319 nm) wavelength regime. Average fluence thresholds for microcavitation increased non-linearly with increasing wavelength. Average fluence thresholds were also measured for 10-ns pulses at 532 nm, and found to be comparable to visible ns pulse values published in previous reports. Fluence thresholds were used to calculate melanosome absorption coefficients, which decreased with increasing wavelength. This trend was found to be comparable to the decrease in retinal pigmented epithelial (RPE) layer absorption coefficients reported over the same wavelength region. Estimated corneal total intraocular energy (TIE) values were determined and compared to the current and proposed maximum permissible exposure (MPE) safe exposure levels. Results from this study support the proposed changes to the MPE levels.

  19. Recent progress in understanding climate thresholds

    NARCIS (Netherlands)

    Good, Peter; Bamber, Jonathan; Halladay, Kate; Harper, Anna B.; Jackson, Laura C.; Kay, Gillian; Kruijt, Bart; Lowe, Jason A.; Phillips, Oliver L.; Ridley, Jeff; Srokosz, Meric; Turley, Carol; Williamson, Phillip

    2018-01-01

    This article reviews recent scientific progress, relating to four major systems that could exhibit threshold behaviour: ice sheets, the Atlantic meridional overturning circulation (AMOC), tropical forests and ecosystem responses to ocean acidification. The focus is on advances since the

  20. Verifiable Secret Redistribution for Threshold Sharing Schemes

    National Research Council Canada - National Science Library

    Wong, Theodore M; Wang, Chenxi; Wing, Jeannette M

    2002-01-01

    .... Our protocol guards against dynamic adversaries. We observe that existing protocols either cannot be readily extended to allow redistribution between different threshold schemes, or have vulnerabilities that allow faulty old shareholders...

  1. Purely absolutely continuous spectrum for almost Mathieu operators

    International Nuclear Information System (INIS)

    Chulaevsky, V.; Delyon, F.

    1989-01-01

    Using a recent result of Sinai, the authors prove that the almost Mathieu operators acting on l 2 (Z), (H αλ Psi)(n) = Ψ(n + 1) + Ψ(n - 1) + λ cos(ωn + α) Ψ(n), have a purely absolutely continuous spectrum for almost all α provided that ω is a good irrational and λ is sufficiently small. Furthermore, the generalized eigenfunctions are quasiperiodic

  2. Absolute calibration and beam background of the Squid Polarimeter

    International Nuclear Information System (INIS)

    Blaskiewicz, M.M.; Cameron, P.R.; Shea, T.J.

    1996-01-01

    The problem of beam background in Squid Polarimetry is not without residual benefits. The authors may deliberately generate beam background by gently kicking the beam at the spin tune frequency. This signal may be used to accomplish a simple and accurate absolute calibration of the polarimeter. The authors present details of beam background calculations and their application to polarimeter calibration, and suggest a simple proof-of-principle accelerator experiment

  3. Results from a U.S. Absolute Gravity Survey,

    Science.gov (United States)

    1982-01-01

    National Bureau of Standards. La . ... ,., 831A08 NOV -2- 1. Introduction We have recently completed an absolute gravity survey at twelve sites in the...Air Force Geophysics Laboratory (AFGL) and the Istituto di Metrologia -7- "G. Colonnetti" (IMGC) [Marson and Alasia, 1978, 19801. All three...for ab- solute measurements of the earth’s gravity, Metrologia , in press, 1982. L 4 !" Table 1. Gravity values transferred to the floor in gal (cm

  4. Blastic plasmacytoid dendritic cell neoplasm with absolute monocytosis at presentation

    Directory of Open Access Journals (Sweden)

    Jaworski JM

    2015-02-01

    Full Text Available Joseph M Jaworski,1,2 Vanlila K Swami,1 Rebecca C Heintzelman,1 Carrie A Cusack,3 Christina L Chung,3 Jeremy Peck,3 Matthew Fanelli,3 Micheal Styler,4 Sanaa Rizk,4 J Steve Hou1 1Department of Pathology and Laboratory Medicine, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 2Department of Pathology, Mercy Fitzgerald Hospital, Darby, PA, USA; 3Department of Dermatology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 4Department of Hematology/Oncology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Blastic plasmacytoid dendritic cell neoplasm is an uncommon malignancy derived from precursors of plasmacytoid dendritic cells. Nearly all patients present initially with cutaneous manifestations, with many having extracutaneous disease additionally. While response to chemotherapy initially is effective, relapse occurs in most, with a leukemic phase ultimately developing. The prognosis is dismal. While most of the clinical and pathologic features are well described, the association and possible prognostic significance between peripheral blood absolute monocytosis (>1.0 K/µL and blastic plasmacytoid dendritic cell neoplasm have not been reported. We report a case of a 68-year-old man who presented with a rash for 4–5 months. On physical examination, there were multiple, dull-pink, indurated plaques on the trunk and extremities. Complete blood count revealed thrombocytopenia, absolute monocytosis of 1.7 K/µL, and a negative flow cytometry study. Biopsy of an abdominal lesion revealed typical features of blastic plasmacytoid dendritic cell neoplasm. Patients having both hematologic and nonhematologic malignancies have an increased incidence of absolute monocytosis. Recent studies examining Hodgkin and non-Hodgkin lymphoma patients have suggested that this is a negative prognostic factor. The association between

  5. Definition of correcting factors for absolute radon content measurement formula

    International Nuclear Information System (INIS)

    Ji Changsong; Xiao Ziyun; Yang Jianfeng

    1992-01-01

    The absolute method of radio content measurement is based on thomas radon measurement formula. It was found in experiment that the systematic error existed in radon content measurement by means of thomas formula. By the analysis on the behaviour of radon daughter five factors including filter efficiency, detector construction factor, self-absorbance, energy spectrum factor, and gravity factor were introduced into the thomas formula, so that the systematic error was eliminated. The measuring methods of the five factors are given

  6. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    International Nuclear Information System (INIS)

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1 rc covering ∼2600-3300 A after removing optical light, and u ∼ 3000-4000 A) compared to a mid-UV filter (uvm2 ∼2000-2400 A). The uvw1 rc - b colors show a scatter of ∼0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, ∼1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  7. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  8. Improved Harmony Search Algorithm with Chaos for Absolute Value Equation

    Directory of Open Access Journals (Sweden)

    Shouheng Tuo

    2013-11-01

    Full Text Available In this paper, an improved harmony search with chaos (HSCH is presented for solving NP-hard absolute value equation (AVE Ax - |x| = b, where A is an arbitrary square matrix whose singular values exceed one. The simulation results in solving some given AVE problems demonstrate that the HSCH algorithm is valid and outperforms the classical HS algorithm (CHS and HS algorithm with differential mutation operator (HSDE.

  9. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    International Nuclear Information System (INIS)

    Sannibale, F.; Stupakov, G.V.; Zolotorev, M.S.; Filippetto, D.; Jagerhofer, L.

    2009-01-01

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  10. Absolute Pitch: Effects of Timbre on Note-Naming Ability

    OpenAIRE

    Vanzella, Patr?cia; Schellenberg, E. Glenn

    2010-01-01

    Background Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP poss...

  11. Assembler absolute forward thick-target bremsstrahlung spectra program

    International Nuclear Information System (INIS)

    Niculescu, V.I.R.; Baciu, G.; Ionescu-Bujor, M.

    1981-12-01

    The program is intended to compute the absolute forward thick-target bremsstrahlung spectrum for electrons in the energy range 1-24 MeV. The program takes into account the following phenomena: multiple scattering, energy loss and the attenuation of the emitted gamma rays. The computer program is written in Assembler having a higher degree of generality and is more performant than the FORTRAN version. (authors)

  12. Integration of Absolute Orientation Measurements in the KinectFusion Reconstruction pipeline

    KAUST Repository

    Giancola, Silvio; Schneider, Jens; Wonka, Peter; Ghanem, Bernard

    2018-01-01

    In this paper, we show how absolute orientation measurements provided by low-cost but high-fidelity IMU sensors can be integrated into the KinectFusion pipeline. We show that integration improves both runtime, robustness and quality of the 3D reconstruction. In particular, we use this orientation data to seed and regularize the ICP registration technique. We also present a technique to filter the pairs of 3D matched points based on the distribution of their distances. This filter is implemented efficiently on the GPU. Estimating the distribution of the distances helps control the number of iterations necessary for the convergence of the ICP algorithm. Finally, we show experimental results that highlight improvements in robustness, a speed-up of almost 12%, and a gain in tracking quality of 53% for the ATE metric on the Freiburg benchmark.

  13. Integration of Absolute Orientation Measurements in the KinectFusion Reconstruction pipeline

    KAUST Repository

    Giancola, Silvio

    2018-02-12

    In this paper, we show how absolute orientation measurements provided by low-cost but high-fidelity IMU sensors can be integrated into the KinectFusion pipeline. We show that integration improves both runtime, robustness and quality of the 3D reconstruction. In particular, we use this orientation data to seed and regularize the ICP registration technique. We also present a technique to filter the pairs of 3D matched points based on the distribution of their distances. This filter is implemented efficiently on the GPU. Estimating the distribution of the distances helps control the number of iterations necessary for the convergence of the ICP algorithm. Finally, we show experimental results that highlight improvements in robustness, a speed-up of almost 12%, and a gain in tracking quality of 53% for the ATE metric on the Freiburg benchmark.

  14. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    Directory of Open Access Journals (Sweden)

    Sammie eTarenskeen

    2015-11-01

    Full Text Available The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a between-participants design, however, we find similar rates of pattern and size overspecification, which are both lower than the rate of colour overspecification. This indicates that although many speakers are more likely to include colour than pattern (probably because colour is more salient, they may also treat pattern like colour due to a tendency towards consistency. We find no increase in size overspecification when the salience of size is increased, suggesting that speakers are more likely to include absolute than relative attributes. However, we do find an increase in size overspecification when mentioning the attributes is triggered, which again shows that speakers tend refer in a consistent manner, and that there are circumstances in which even size overspecification is frequently produced.

  15. Philosophy as Inquiry Aimed at the Absolute Knowledge

    Directory of Open Access Journals (Sweden)

    Ekaterina Snarskaya

    2017-09-01

    Full Text Available Philosophy as the absolute knowledge has been studied from two different but closely related approaches: historical and logical. The first approach exposes four main stages in the history of European metaphysics that marked out types of “philosophical absolutism”: the evolution of philosophy brought to light metaphysics of being, method, morals and logic. All of them are associated with the names of Aristotle, Bacon/Descartes, Kant and Hegel. Then these forms are considered in the second approach that defined them as subject-matter of philosophy as such. Due to their overall, comprehensive character, the focus of philosophy on them justifies its claim on absoluteness as far as philosophy is aimed at comprehension of the world’s unity regardless of the philosopher’s background, values and other preferences. And that is its prerogative since no other form of consciousness lays down this kind of aim. Thus, philosophy is defined as an everlasting attempt to succeed in conceiving the world in all its multifold manifestations. This article is to try to clarify the claim of philosophy on the absolute knowledge.

  16. A vibration correction method for free-fall absolute gravimeters

    Science.gov (United States)

    Qian, J.; Wang, G.; Wu, K.; Wang, L. J.

    2018-02-01

    An accurate determination of gravitational acceleration, usually approximated as 9.8 m s-2, has been playing an important role in the areas of metrology, geophysics, and geodetics. Absolute gravimetry has been experiencing rapid developments in recent years. Most absolute gravimeters today employ a free-fall method to measure gravitational acceleration. Noise from ground vibration has become one of the most serious factors limiting measurement precision. Compared to vibration isolators, the vibration correction method is a simple and feasible way to reduce the influence of ground vibrations. A modified vibration correction method is proposed and demonstrated. A two-dimensional golden section search algorithm is used to search for the best parameters of the hypothetical transfer function. Experiments using a T-1 absolute gravimeter are performed. It is verified that for an identical group of drop data, the modified method proposed in this paper can achieve better correction effects with much less computation than previous methods. Compared to vibration isolators, the correction method applies to more hostile environments and even dynamic platforms, and is expected to be used in a wider range of applications.

  17. Absolute photoionization cross-section of the propargyl radical

    Energy Technology Data Exchange (ETDEWEB)

    Savee, John D.; Welz, Oliver; Taatjes, Craig A.; Osborn, David L. [Sandia National Laboratories, Combustion Research Facility, Livermore, California 94551 (United States); Soorkia, Satchin [Institut des Sciences Moleculaires d' Orsay, Universite Paris-Sud 11, Orsay (France); Selby, Talitha M. [Department of Chemistry, University of Wisconsin, Washington County Campus, West Bend, Wisconsin 53095 (United States)

    2012-04-07

    Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

  18. An absolute distance interferometer with two external cavity diode lasers

    International Nuclear Information System (INIS)

    Hartmann, L; Meiners-Hagen, K; Abou-Zeid, A

    2008-01-01

    An absolute interferometer for length measurements in the range of several metres has been developed. The use of two external cavity diode lasers allows the implementation of a two-step procedure which combines the length measurement with a variable synthetic wavelength and its interpolation with a fixed synthetic wavelength. This synthetic wavelength is obtained at ≈42 µm by a modulation-free stabilization of both lasers to Doppler-reduced rubidium absorption lines. A stable reference interferometer is used as length standard. Different contributions to the total measurement uncertainty are discussed. It is shown that the measurement uncertainty can considerably be reduced by correcting the influence of vibrations on the measurement result and by applying linear regression to the quadrature signals of the absolute interferometer and the reference interferometer. The comparison of the absolute interferometer with a counting interferometer for distances up to 2 m results in a linearity error of 0.4 µm in good agreement with an estimation of the measurement uncertainty

  19. Absolute surface reconstruction by slope metrology and photogrammetry

    Science.gov (United States)

    Dong, Yue

    Developing the manufacture of aspheric and freeform optical elements requires an advanced metrology method which is capable of inspecting these elements with arbitrary freeform surfaces. In this dissertation, a new surface measurement scheme is investigated for such a purpose, which is to measure the absolute surface shape of an object under test through its surface slope information obtained by photogrammetric measurement. A laser beam propagating toward the object reflects on its surface while the vectors of the incident and reflected beams are evaluated from the four spots they leave on the two parallel transparent windows in front of the object. The spots' spatial coordinates are determined by photogrammetry. With the knowledge of the incident and reflected beam vectors, the local slope information of the object surface is obtained through vector calculus and finally yields the absolute object surface profile by a reconstruction algorithm. An experimental setup is designed and the proposed measuring principle is experimentally demonstrated by measuring the absolute surface shape of a spherical mirror. The measurement uncertainty is analyzed, and efforts for improvement are made accordingly. In particular, structured windows are designed and fabricated to generate uniform scattering spots left by the transmitted laser beams. Calibration of the fringe reflection instrument, another typical surface slope measurement method, is also reported in the dissertation. Finally, a method for uncertainty analysis of a photogrammetry measurement system by optical simulation is investigated.

  20. Absolutely minimal extensions of functions on metric spaces

    International Nuclear Information System (INIS)

    Milman, V A

    1999-01-01

    Extensions of a real-valued function from the boundary ∂X 0 of an open subset X 0 of a metric space (X,d) to X 0 are discussed. For the broad class of initial data coming under discussion (linearly bounded functions) locally Lipschitz extensions to X 0 that preserve localized moduli of continuity are constructed. In the set of these extensions an absolutely minimal extension is selected, which was considered before by Aronsson for Lipschitz initial functions in the case X 0 subset of R n . An absolutely minimal extension can be regarded as an ∞-harmonic function, that is, a limit of p-harmonic functions as p→+∞. The proof of the existence of absolutely minimal extensions in a metric space with intrinsic metric is carried out by the Perron method. To this end, ∞-subharmonic, ∞-superharmonic, and ∞-harmonic functions on a metric space are defined and their properties are established

  1. Local absolute alcohol ablation for the treatment of recurrent pheochromocytoma

    International Nuclear Information System (INIS)

    Shang Mingyi; Wang Peijun; Lu Ying; Ma Jun; Tang Junjun; Xi Qian; Huang Zongliang; Gao Xiaolong

    2010-01-01

    Objective: to assess the clinical value of local injection of absolute alcohol under CT guidance in treating recurrent pheochromocytoma. Methods: Five patients with benign recurrent pheochromocytoma were enrolled in this study. Of the five cases, the lesions were located on the right side in three, on the left in one and on both sides in one. All the lesions were pathologically proved to be benign ones. Under CT guidance the ablation therapy with local injection of absolute alcohol was performed. The therapeutic results were observed and evaluated. Results: Thirty days after the treatment, different degrees of decrease in tumor size was observed on follow-up CT scans. All the patients were followed up for 9-42 months. During the follow-up period, both the blood pressure and the vanillyl mandelic acid (VMA) level in urine remained normal and no paroxysmal dizziness, headache or syncope occurred in all patients. Conclusion: For the treatment of recurrent pheochromocytoma the ablation therapy by using local injection of absolute alcohol under CT guidance is a safe and practical therapeutic means with definite and reliable effectiveness. (authors)

  2. Thresholding projection estimators in functional linear models

    OpenAIRE

    Cardot, Hervé; Johannes, Jan

    2010-01-01

    We consider the problem of estimating the regression function in functional linear regression models by proposing a new type of projection estimators which combine dimension reduction and thresholding. The introduction of a threshold rule allows to get consistency under broad assumptions as well as minimax rates of convergence under additional regularity hypotheses. We also consider the particular case of Sobolev spaces generated by the trigonometric basis which permits to get easily mean squ...

  3. Noise thresholds for optical quantum computers.

    Science.gov (United States)

    Dawson, Christopher M; Haselgrove, Henry L; Nielsen, Michael A

    2006-01-20

    In this Letter we numerically investigate the fault-tolerant threshold for optical cluster-state quantum computing. We allow both photon loss noise and depolarizing noise (as a general proxy for all local noise), and obtain a threshold region of allowed pairs of values for the two types of noise. Roughly speaking, our results show that scalable optical quantum computing is possible for photon loss probabilities <3 x 10(-3), and for depolarization probabilities <10(-4).

  4. Design of Threshold Controller Based Chaotic Circuits

    DEFF Research Database (Denmark)

    Mohamed, I. Raja; Murali, K.; Sinha, Sudeshna

    2010-01-01

    We propose a very simple implementation of a second-order nonautonomous chaotic oscillator, using a threshold controller as the only source of nonlinearity. We demonstrate the efficacy and simplicity of our design through numerical and experimental results. Further, we show that this approach...... of using a threshold controller as a nonlinear element, can be extended to obtain autonomous and multiscroll chaotic attractor circuits as well....

  5. The absolute photoionization cross sections of helium, neon, argon and krypton in the extreme vacuum ultraviolet region of the spectrum

    International Nuclear Information System (INIS)

    West, J.B.; Marr, G.V.

    1976-01-01

    An experiment has been set up at the Daresbury Synchrotron Radiation Facility to make absolute absorption cross section measurements over a wide range of photon energies. New data are reported for helium, neon, argon and krypton over the range 340 to 40 A which are believed to be reliable to +- 5%. A critical evaluation of published cross section data has been carried out to produce best value data from the ionization thresholds throughout the vacuum ultraviolet and x-ray region. Agreement with theoretical calculations on helium is demonstrated to be within +- 2 to 3% from threshold down to the double ionization threshold at 79 eV. Comparison with recent calculations of photoionization cross sections has shown that the effect of electron correlations is significant for the heavier inert gases. Contrary to previous claims, the position of the M shell maximum in krypton is located at 184 +- 10 eV in good agreement with r.p.a.e. calculations. Oscillator strength sum rules have been examined and their moments calculated. Discrepancies developing towards the heavier inert gases suggests a decrease in polarizabilities and other atomic factors from those predicted by Hartree-Fock calculations. (author)

  6. A New Wavelet Threshold Function and Denoising Application

    Directory of Open Access Journals (Sweden)

    Lu Jing-yi

    2016-01-01

    Full Text Available In order to improve the effects of denoising, this paper introduces the basic principles of wavelet threshold denoising and traditional structures threshold functions. Meanwhile, it proposes wavelet threshold function and fixed threshold formula which are both improved here. First, this paper studies the problems existing in the traditional wavelet threshold functions and introduces the adjustment factors to construct the new threshold function basis on soft threshold function. Then, it studies the fixed threshold and introduces the logarithmic function of layer number of wavelet decomposition to design the new fixed threshold formula. Finally, this paper uses hard threshold, soft threshold, Garrote threshold, and improved threshold function to denoise different signals. And the paper also calculates signal-to-noise (SNR and mean square errors (MSE of the hard threshold functions, soft thresholding functions, Garrote threshold functions, and the improved threshold function after denoising. Theoretical analysis and experimental results showed that the proposed approach could improve soft threshold functions with constant deviation and hard threshold with discontinuous function problems. The proposed approach could improve the different decomposition scales that adopt the same threshold value to deal with the noise problems, also effectively filter the noise in the signals, and improve the SNR and reduce the MSE of output signals.

  7. Anomalous phenomena in ECRH experiments at toroidal devices and low-threshold parametric decay instabilities

    Directory of Open Access Journals (Sweden)

    Saveliev A.N.

    2012-09-01

    Full Text Available In the paper the possibility of total 3D trapping of electron Bernstein (EB waves in the tokamak equatorial plane in the vicinity of the local density maximum produced by electron pump-out-effect is demonstrated. Thresholds and growth rates of the associated absolute (temporally growing parametric decay instability (PDI leading to anomalous absorption is predicted in the range of less than 100 kW. Its possible role in explanation of ion acceleration observed in ECRH experiments as well as in redistribution of the deposited power is discussed.

  8. Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

    Directory of Open Access Journals (Sweden)

    Djibril Wade

    Full Text Available A new CD4 point-of-care instrument, the CyFlow miniPOC, which provides absolute and percentage CD4 T-cells, used for screening and monitoring of HIV-infected patients in resource-limited settings, was introduced recently. We assessed the performance of this novel instrument in a reference laboratory and in a field setting in Senegal.A total of 321 blood samples were obtained from 297 adults and 24 children, all HIV-patients attending university hospitals in Dakar, or health centers in Ziguinchor. Samples were analyzed in parallel on CyFlow miniPOC, FACSCount CD4 and FACSCalibur to assess CyFlow miniPOC precision and accuracy.At the reference lab, CyFlow miniPOC, compared to FACSCalibur, showed an absolute mean bias of -12.6 cells/mm3 and a corresponding relative mean bias of -2.3% for absolute CD4 counts. For CD4 percentages, the absolute mean bias was -0.1%. Compared to FACSCount CD4, the absolute and relative mean biases were -31.2 cells/mm3 and -4.7%, respectively, for CD4 counts, whereas the absolute mean bias for CD4 percentages was 1.3%. The CyFlow miniPOC was able to classify HIV-patients eligible for ART with a sensitivity of ≥ 95% at the different ART-initiation thresholds (200, 350 and 500 CD4 cells/mm3. In the field lab, the room temperature ranged from 30 to 35°C during the working hours. At those temperatures, the CyFlow miniPOC, compared to FACSCount CD4, had an absolute and relative mean bias of 7.6 cells/mm3 and 2.8%, respectively, for absolute CD4 counts, and an absolute mean bias of 0.4% for CD4 percentages. The CyFlow miniPOC showed sensitivity equal or greater than 94%.The CyFlow miniPOC showed high agreement with FACSCalibur and FACSCount CD4. The CyFlow miniPOC provides both reliable absolute CD4 counts and CD4 percentages even under the field conditions, and is suitable for monitoring HIV-infected patients in resource-limited settings.

  9. Simulating threshold voltage shift of MOS devices due to radiation in the low-dose range

    CERN Document Server

    Wan Xin Heng; Gao Wen Yu; Huang Ru; Wang Yang Yuan

    2002-01-01

    An analytical MOSFET threshold voltage shift model due to radiation in the low-dose range has been developed for circuit simulations. Experimental data in the literature shows that the model predictions are in good agreement. It is simple in functional form and hence computationally efficient. It can be used as a basic circuit simulation tool for analysing MOSFET exposed to a nuclear environment up to about 1 Mrad(Si). In accordance with common believe, radiation induced absolute change of threshold voltage was found to be larger in irradiated PMOS devices. However, if the radiation sensitivity is defined in the way authors did it, the results indicated NMOS rather than PMOS devices are more sensitive, specially at low doses. This is important from the standpoint of their possible application in dosimetry

  10. Incorporation of threshold phenomena in the three-body Coulomb continuum wavefunctions

    International Nuclear Information System (INIS)

    Berakdar, J.

    1996-01-01

    In this work a three-body Coulomb wavefunction for the description of two continuum electrons moving in the field of a nucleus is constructed such that the Wannier threshold law for double escape is reproduced and the asymptotic Coulomb boundary conditions as well as the Kato cusp conditions are satisfied. It is shown that the absolute value of the total cross section, as well as the spin asymmetry, are well described by the present approach. Further, the excess-energy sharing between the two escaping electrons is calculated and analysed in light of the Wannier theory predictions. This is the first time an analytical three-body wavefunction is presented which is asymptotically exact and capable of describing threshold phenomena. 37 refs., 3 figs

  11. Influence of optical feedback on laser frequency spectrum and threshold conditions

    DEFF Research Database (Denmark)

    Osmundsen, Jens Henrik; Gade, Niels

    1983-01-01

    The steady state behavior of the external cavity operated laser has been analyzed, taking into account multiple reflections. The effect of optical feedback is included in the phase- and gain-conditions by a factor which is shown to have a simple geometrical representation. From this representation...... it is easily seen how the laser frequency spectrum and the threshold gain depend on external parameters such as distance to the reflection point and the amount of optical feedback. Furthermore, by inserting a variable attenuator in the external cavity and measuring the threshold current versus transmittance we...... have simultaneously determined the photon lifetime and the absolute amount of optical feedback. For the laser considered we found the photon lifetimetau_{p} = 1.55ps....

  12. Application of Mean of Absolute Deviation Method for the Selection of Best Nonlinear Component Based on Video Encryption

    Science.gov (United States)

    Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar

    2013-07-01

    The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.

  13. Financial Development and Inclusive Growth in Nigeria: A Threshold Analysis

    Directory of Open Access Journals (Sweden)

    Taofeek Olusola Ayinde

    2016-10-01

    Full Text Available This study investigates the relationship between financial development and inclusive growth in Nigeria for the period 1980 – 2013. The technique of analysis is the quantile regression; which is to obtain a threshold for which the former impacts on the latter. The result shows a threshold level of 90th percentile. Interestingly, the study also found that the impact of financial development on inclusive growth depends on the measure of the former up to the threshold level and not beyond. Through a granger causality test, the direction of causality is through the inclusive growth rather than through financial development; through the financial deepening measure. While the study found that either a low level or high level of openness on trade and capital investment are desirable for inclusive growth in Nigeria, the results also reveal that government involvement in the workings of the Nigeria economy and financial openness are sensitive to the pattern of financial development. With financial deepening, both are negatively related to inclusive growth but positively related to inclusive growth when financial widening is considered. This suggests that government intervention in the activities of the private sector is detrimental when the latter are to drive financial development process. However, the involvement of government in ensuring the appropriate level of financial widening, through the central bank operations, produces a positive impact on growth.

  14. Financial Development and Inclusive Growth in Nigeria: A Threshold Analysis

    Directory of Open Access Journals (Sweden)

    Taofeek Olusola Ayinde

    2016-08-01

    Full Text Available This study investigates the relationship between financial development and inclusive growth in Nigeria for the period 1980 – 2013. The technique of analysis is the quantile regression; which is to obtain a threshold for which the former impacts on the latter. The result shows a threshold level of 90th percentile. Interestingly, the study also found that the impact of financial development on inclusive growth depends on the measure of the former up to the threshold level and not beyond. Through a granger causality test, the direction of causality is through the inclusive growth rather than through financial development; through the financial deepening measure. While the study found that either a low level or high level of openness on trade and capital investment are desirable for inclusive growth in Nigeria, the results also reveal that government involvement in the workings of the Nigeria economy and financial openness are sensitive to the pattern of financial development. With financial deepening, both are negatively related to inclusive growth but positively related to inclusive growth when financial widening is considered. This suggests that government intervention in the activities of the private sector is detrimental when the latter are to drive financial development process. However, the involvement of government in ensuring the appropriate level of financial widening, through the central bank operations, produces a positive impact on growth.

  15. Multiple pulse nanosecond laser induced damage threshold on hybrid mirrors

    Science.gov (United States)

    Vanda, Jan; Muresan, Mihai-George; Bilek, Vojtech; Sebek, Matej; Hanus, Martin; Lucianetti, Antonio; Rostohar, Danijela; Mocek, Tomas; Škoda, Václav

    2017-11-01

    So-called hybrid mirrors, consisting of broadband metallic surface coated with dielectric reflector designed for specific wavelength, becoming more important with progressing development of broadband mid-IR sources realized using parametric down conversion system. Multiple pulse nanosecond laser induced damage on such mirrors was tested by method s-on-1, where s stands for various numbers of pulses. We show difference in damage threshold between common protected silver mirrors and hybrid silver mirrors prepared by PVD technique and their variants prepared by IAD. Keywords: LIDT,

  16. Derivation of critical rainfall thresholds for landslide in Sicily

    Science.gov (United States)

    Caracciolo, Domenico; Arnone, Elisa; Noto, Leonardo V.

    2015-04-01

    Rainfall is the primary trigger of shallow landslides that can cause fatalities, damage to properties and economic losses in many areas of the world. For this reason, determining the rainfall amount/intensity responsible for landslide occurrence is important, and may contribute to mitigate the related risk and save lives. Efforts have been made in different countries to investigate triggering conditions in order to define landslide-triggering rainfall thresholds. The rainfall thresholds are generally described by a functional relationship of power in terms of cumulated or intensity event rainfall-duration, whose parameters are estimated empirically from the analysis of historical rainfall events that triggered landslides. The aim of this paper is the derivation of critical rainfall thresholds for landslide occurrence in Sicily, southern Italy, by focusing particularly on the role of the antecedent wet conditions. The creation of the appropriate landslide-rainfall database likely represents one of main efforts in this type of analysis. For this work, historical landslide events occurred in Sicily from 1919 to 2001 were selected from the archive of the Sistema Informativo sulle Catastrofi Idrogeologiche, developed under the project Aree Vulnerabili Italiane. The corresponding triggering precipitations were screened from the raingauges network in Sicily, maintained by the Osservatorio delle Acque - Agenzia Regionale per i Rifiuti e le Acque. In particular, a detailed analysis was carried out to identify and reconstruct the hourly rainfall events that caused the selected landslides. A bootstrapping statistical technique has been used to determine the uncertainties associated with the threshold parameters. The rainfall thresholds at different exceedance probability levels, from 1% to 10%, were defined in terms of cumulated event rainfall, E, and rainfall duration, D. The role of rainfall prior to the damaging events was taken into account by including in the analysis

  17. Towards absolute quantification of allergenic proteins in food--lysozyme in wine as a model system for metrologically traceable mass spectrometric methods and certified reference materials.

    Science.gov (United States)

    Cryar, Adam; Pritchard, Caroline; Burkitt, William; Walker, Michael; O'Connor, Gavin; Burns, Duncan Thorburn; Quaglia, Milena

    2013-01-01

    Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.

  18. Absolute dimensions of eclipsing binaries XXVII. V1130 tauri

    DEFF Research Database (Denmark)

    Clausen, Jens Viggo; Olsen, E, H.; Helt, B. E.

    2010-01-01

    stars: evolution / stars: fundamental parameters / stars: individual: V1130¿Tau / binaries: eclipsing / techniques: photometric / techniques: radial velocities Udgivelsesdato: 17 Feb.......stars: evolution / stars: fundamental parameters / stars: individual: V1130¿Tau / binaries: eclipsing / techniques: photometric / techniques: radial velocities Udgivelsesdato: 17 Feb....

  19. Probabilistic performance estimators for computational chemistry methods: The empirical cumulative distribution function of absolute errors

    Science.gov (United States)

    Pernot, Pascal; Savin, Andreas

    2018-06-01

    Benchmarking studies in computational chemistry use reference datasets to assess the accuracy of a method through error statistics. The commonly used error statistics, such as the mean signed and mean unsigned errors, do not inform end-users on the expected amplitude of prediction errors attached to these methods. We show that, the distributions of model errors being neither normal nor zero-centered, these error statistics cannot be used to infer prediction error probabilities. To overcome this limitation, we advocate for the use of more informative statistics, based on the empirical cumulative distribution function of unsigned errors, namely, (1) the probability for a new calculation to have an absolute error below a chosen threshold and (2) the maximal amplitude of errors one can expect with a chosen high confidence level. Those statistics are also shown to be well suited for benchmarking and ranking studies. Moreover, the standard error on all benchmarking statistics depends on the size of the reference dataset. Systematic publication of these standard errors would be very helpful to assess the statistical reliability of benchmarking conclusions.

  20. Investigation of the Periodic Absolute Parametric Instability in a Nonuniform Cylindrical Warm Plasma Waveguide

    International Nuclear Information System (INIS)

    Zaki, N.G.

    2009-01-01

    In this paper, the effect of spatial plasma nonuniformity on periodic Absolute Parametric Instability (API) of electrostatic waves in a magnetized pump warm plasma is investigated in a cylindrical geometry. An API plays a crucial role in the processes of the energy transfer from the electromagnetic radiation to the plasma and may have an important consequences for experiments on RF plasma heating in a magnetic traps and for a laser-fusion system. In conclusion; it is found that: A) allowance for the spatial nonuniformity of the plasma density leads to A.I) localization of an unstable wave in a finite region of a plasma volume, A.2) increasing the threshold value of the pump wave amplitude above which parametric amplification occurs and A.3) decreasing the value of the growth rate of unstable waves, B) more growth rate of periodic API is decreased due to electrons warmness in comparison with the case of cold plasma, and C) Independent of the geometry of the problem ( plane or cylinder), the results of the API in a warm plasma waveguide are still valid