WorldWideScience

Sample records for absolute thellier paleointensities

  1. Assessment of Magnetostatic Interaction Effects on Thellier Paleointensity Determination by Experimental Simulations

    Science.gov (United States)

    Zheng, Z.; Zhao, X.

    2009-05-01

    The ability to control magnetic interactions between grains is of fundamental importance in paleointensity studies. We continued to perform experimental simulations to help understand the effect of magnetostatic interaction on Thellier type paleointensity experiments, using artificial synthesized magnetite grains mixed with both pseudo-single domain (PSD) and multidomain (MD) particles. Magnetite powders were mixed either with an Aron ceramic or were dispersed in matrix of Seto porcelain clay. The effects of interaction between grains can be observed from the magnetic behavior of specimens with different inter-grain distances. The maximum effect of domain's interaction can be estimated by comparing the behavior of specimens with large inter-grain distance (i.e., mostly dispersed-grains) with that of ideal non-interacting SD grains. Our results clearly show that (1) the interaction between grains (rather than domain's interaction) has particular disastrous effects on the Thellier-Coe paleointensity experiment; (2) interaction of large inter- grain distance samples adds an almost negative constant value to the applied external field (i.e., acting as an internal demagnetizing field); (3) interaction in shorter inter-grain distance samples mainly generates the difference in blocking and unblocking temperatures of the sample. Detailed results will be presented and discussed at the meeting.

  2. A LabVIEW software for Thellier paleointensity measurements with an automated three-component spinner magnetometer TSpin

    Science.gov (United States)

    Fukuma, Koji; Kono, Masaru

    2016-03-01

    The Thellier method is classical but is still regarded as the most reliable method for paleointensity determination. Recently, many types of additional protocols have been advocated to ensure reliability and make laboratory work more laborious and time-consuming. An automated system coupling a magnetometer and an electric furnace is now of prime importance to cope with the increasing demand. Here, we describe a graphics-based program for controlling a fully automatic system combining a spinner magnetometer and a thermal demagnetizer, and for acquiring and processing the magnetization data. A single fluxgate sensor, which can measure the vector magnetization by spinning and translating a standard-sized 1-in. specimen, was calibrated with a rotatable reference specimen that can make the magnetization parallel or perpendicular to the spinning axis. By placing a cooling chamber between the furnace and the sensor for the updated system, the specimen can be heated up more efficiently to ensure an identical thermal history for the double heatings of the Thellier method. The direction of the vector magnetization was precisely obtained as well as the intensity, the results being comparable with those from an ordinary spinner magnetometer. We present an application of the fully automatic system for a Thellier measurement on a recent lava flow, which took about 24 h for approximately ten-step double heatings without manual operation.

  3. Absolute paleointensity determinations by using of conventional double-heating and multispecimen approaches on a Pliocene lava flow sequence from the Lesser Caucasus

    Science.gov (United States)

    Goguitchaichvili, Avto; Caccavari, Ana; Calvo-Rathert, Manuel; Morales, Juan; Solano, Miguel Cervantes; Vashakidze, Goga; Huaiyu, He; Vegas, Néstor

    2016-08-01

    We report 28 successful Thellier type absolute geomagnetic paleointensity determinations from a Pleistocene lava sequence composed of 39 successive flows in the Djavakheti Highland (Lesser Caucasus, Georgia). Additionally, multispecimen technique provided the estimation of geomagnetic field strength for 12 independent cooling units. Paleointensity studies were performed using both Thellier type double heating and multispecimen techniques. Samples selection was mainly based on uni-vectorial remanent magnetization, thermal stability and domain size of the samples. Flow-mean Thellier paleointensity values range from 16.3 ± 5.2 to 71.0 ± 0.3 μT, while intensities obtained using multispecimen approach vary from17.2 ± 2.3 to 69.3 ± 7.9 μT. One of the flows is located near a possible discontinuity in the sequence and yields a rather low Thellier absolute intensity (16.3 ± 5.2) suggesting a transitional regime and the onset of the Matuyama-Olduvai polarity transition, which does not appear on the directional record. Multispecimen paleointensities from the same flow, however, yield higher, close to present day values which makes untenable the hypothesis of occurrence of transitional field. Thus the whole sequence was emplaced in a short time between the Olduvai chron and 1.73 ± 0.03 Ma, as suggested by available radiometric and paleomagnetic data (Caccavari et al., 2014).

  4. Absolute paleointensity of the Earth's magnetic field during Jurassic: case study of La Negra Formation (northern Chile)

    Science.gov (United States)

    Morales, Juan; Goguitchaichvili, Avto; Alva-Valdivia, Luis M.; Urrutia-Fucugauchi, Jaime

    2003-08-01

    We carried out a detailed rock-magnetic and paleointensity study of the ˜187-Ma volcanic succession from northern Chile. A total of 32 consecutive lava flows (about 280 oriented standard paleomagnetic cores) were collected at the Tocopilla locality. Only 26 samples with apparently preserved primary magnetic mineralogy and without secondary magnetization components were pre-selected for Thellier paleointensity determination. Eleven samples coming from four lava flows yielded reliable paleointensity estimates. The flow-mean virtual dipole moments range from 3.7±0.9 to 7.1±0.5 (10 22 A m 2). This corresponds to a mean value of (5.0±1.8)×10 22 A m 2, which is in reasonably good agreement with other comparable quality paleointensity determinations from the Middle Jurassic. Given the large dispersion and the very poor distribution of reliable absolute intensity data, it is hard to draw any firm conclusions regarding the time evolution of the geomagnetic field. To cite this article: J. Morales et al., C. R. Geoscience 335 (2003).

  5. Absolute paleointensity from Hawaiian lavas younger than 35 ka

    Science.gov (United States)

    Valet, J.-P.; Tric, E.; Herrero-Bervera, E.; Meynadier, L.; Lockwood, J.P.

    1998-01-01

    Paleointensity studies have been conducted in air and in argon atmosphere on nine lava flows with radiocarbon ages distributed between 3.3 and 28.2 ka from the Mauna Loa volcano in the big island of Hawaii. Determinations of paleointensity obtained at eight sites depict the same overall pattern as the previous results for the same period in Hawaii, although the overall average field intensity appears to be lower. Since the present results were determined at higher temperatures than in the previous studies, this discrepancy raises questions regarding the selection of low versus high-temperature segments that are usually made for absolute paleointensity. The virtual dipole moments are similar to those displayed by the worldwide data set obtained from dated lava flows. When averaged within finite time intervals, the worldwide values match nicely the variations of the Sint-200 synthetic record of relative paleointensity and confirm the overall decrease of the dipole field intensity during most of this period. The convergence between the existing records at Hawaii and the rest of the world does not favour the presence of persistent strong non-dipole components beneath Hawaii for this period.

  6. High quality absolute paleointensity data from Santa Fe, New Mexico

    Science.gov (United States)

    Jones, S. A.; Tauxe, L.; Blinman, E.; Genevey, A.

    2015-12-01

    Preliminary paleointensity experiments were conducted using the IZZI protocol on one hundred and fourteen specimens from fifty-seven baked pottery fragments collected from nine archaeological sites near Santa Fe, New Mexico. Twenty of these fragments passed our weakest selection criteria. Seven additional specimens were made from each passing fragment for further paleointensity experiments. The results of these second experiments indicate that the samples are mildly anisotropic, so anisotropy experiments were conducted to correct for this behavior. Experiments to determine the cooling rate correction will be completed to ensure the robustness of the dataset. Stylistic evidence, historical documentation, dendrochronology, and 14C analyses provide age constraints with up to decade resolution for the VADM results. The twenty pottery fragments analyzed span five distinct time periods between 1300 and 1900 AD. Our new results for each fragment differ slightly from those predicted by the cals3k.4b and arch3k models, suggesting the models require refinement. This is expected because there are few archaeomagnetic constraints on the models from this region. Future pottery fragments and burned adobe fragments from the New Mexico area will be analyzed for paleointensity and combined with our pottery fragment data set to create a high-resolution paleointensity curve for the recent archaeological time in the American Southwest.

  7. A whole rock absolute paleointensity determination of dacites from the Duffer Formation (ca. 3.467 Ga) of the Pilbara Craton, Australia: An impossible task?

    Science.gov (United States)

    Herrero-Bervera, Emilio; Krasa, David; Van Kranendonk, Martin J.

    2016-09-01

    We have conducted a whole-rock type magnetic and absolute paleointensity determination of the red dacite of the Duffer Formation from the Pilbara Craton, Australia. The age of the dated rock unit is 3467 ± 5 Ma (95% confidence). Vector analyses results of the step-wise alternating field demagnetization (NRM up to 100 mT) and thermal demagnetization (from NRM up to 650 °C) yield three components of magnetization. Curie point determinations indicate three characteristic temperatures, one at 150-200 °C, a second one at ∼450 °C and a third one at ∼580 °C. Magnetic grain-size experiments were performed on small specimens with a variable field translation balance (VFTB). The coercivity of remanence (Hcr) suggests that the NRM is carried by low-coercivity grains that are associated with a magnetite fraction as is shown by the high-temperature component with blocking temperatures above 450 °C and up to at least 580 °C. The ratios of the hysteresis parameters plotted as a modified Day diagram show that most grain sizes are scattered within the Single Domain (SD) and the Superparamagnetic and Single Domain SP-SD domain ranges. In addition to the rock magnetic experiments we have performed absolute paleointensity experiments on the samples using the modified Thellier-Coe double heating method to determine the paleointensities. Partial-TRM (p-TRM) checks were performed systematically to document magnetomineralogical changes during heating. The temperature was incremented by steps of 50 °C between room temperature and 590 °C. The paleointensity determinations were obtained from the slope of Arai diagrams. Our paleointensity results indicate that the paleofield obtained was ∼6.4 ± 0.68 (N = 11) micro-Teslas with a Virtual Dipole Moment (VDM) of 1.51 ± 0.81 × 1022 Am2, from a medium-to high-temperature component ranging from 300 to 590 °C that has been interpreted to be the oldest magnetization yet recorded in paleomagnetic studies of the Duffer Formation. The

  8. Room-temperature instability of TRM and the problem of estimating absolute paleointensity from non single domain materials.

    Science.gov (United States)

    Shaar, R.; Tauxe, L.

    2015-12-01

    Absolute paleointensity data are essential for understanding Earth's deep interior, climatic modeling, and geochronology applications, among others. Paleointensity data are derived from experiments in which the ancient TRM is replaced by a laboratory controlled TRM. This procedure is built on the assumption that the process of ancient TRM acquisition is entirely reproducible in the lab. Here we show experimental results violating this assumption in a manner not expected from standard theory. We prepared 118 pairs of nearly identical specimens. One specimen from each pair was given laboratory TRM and allowed to "age" in a controlled fixed field, identical and parallel to the laboratory TRM field, for two years. After two years the second specimen was given a "fresh" TRM. Thus, the two specimens in each pair differ in only one significant respect: the time elapsed from the TRM acquisition. We carried out IZZI-type absolute paleointensity experiments on the two groups. Under the assumption of TRM stability we expect that the behavior of the twin specimens in the experiment would be exactly the same. Yet, we found a small but systematic difference between the "aged" and the "fresh" TRM. The "aged" TRM yield more curved and zigzaggy Arai plots, and exhibit a shift in the blocking/unblocking spectra. This effect leads to a systematic bias in paleointensity estimates caused only by room-temperature instability of TRM. The change in TRM properties is likely caused by irreversible changes in micromagnetic structures of non single domains.

  9. Isolating the actual signal of paleointensity?

    Science.gov (United States)

    Valet, J. M.; Moreno, E.; Bassinot, F.; Herrero-Bervera, E.

    2011-12-01

    Signals of relative and absolute paleointensity suffer inaccuracies and contaminations that must be considered to improve our knowledge of the field variations. Climatically related changes in rock magnetic parameters are frequently suspected of influencing the signal of relative paleointensity extrated from marine sediments. High resolution measurements of climatic and magnetic parameters have been performed on two cores from the eastern China Sea and the western Caroline Basin. On both cores, magnetic parameters show a strong imprint of climatic changes but the absence of relationship between the inclination and the bulk density indicates that the directional changes do not depend on lithology. All normalization parameters yielded similar estimates of relative paleointensity (RPI), but we have noticed the persistence of climatic components in the signal. Principal Component Analysis (PCA) applied to different parameters related to climate, lithology and paleointensity has allowed to extract a "clean" magnetic signal that we refer as "principal component of paleointensity (PCP)" which is in better agreement with the Sint-2000 composite curve and provides a reliable record of relative paleointensity. The presence of climatic frequencies in RPIs most likely reflects the influence of lithology on the response of magnetization to field intensity. We suggest that PCA analysis can be very useful to approach these problems. Not only can the calculation separate overlapping climatic and magnetic signals, but it indicates what confidence should be given to the data. Incidentally, the present results emphasize the importance of carrying out detailed paleoclimatic analyses along with paleointensity studies. Many approaches have been proposed during the past 20 years for experiments of absolute paleointensity in order to reduce the duration of the experiments and increase the number of field determinations. However, this is frequently obtained to the detriment of the accuracy

  10. Paleomagnetic intensity of Aso pyroclastic flows: Additional results with LTD-DHT Shaw method, Thellier method with pTRM-tail check

    Science.gov (United States)

    Maruuchi, T.; Shibuya, H.

    2009-12-01

    For the sake to calibrate the absolute value of the ’relative paleointensity variation curve’ drawn from sediment cores, Takai et al. (2002) proposed to use pyroclastic flows co-bearing with wide spread tephras. The pyroclastic flows prepare volcanic rocks with TRM, which let us determine absolute paleointensity, and the tephras prepare the correlation with sediment stratigraphy. While 4 out of 6 pyroclastic flows are consistent with Sint-800 paleointensity variation curve, two flows, Aso-2 and Aso-4, show weaker and stronger than Sint-800 beyond the error, respectively. We revisited the paleointensity study of Aso pyroclastic flows, adding LTD- DHT Shaw method, the pTRM-tail check in Thellier experiment, and LTD-DHT Shaw method by using volcanic glasses. We prepared 11 specimens from 3 sites of Aso-1 welded tuff for LTD-DHT Shaw method experiments, and obtained 6 paleointensities satisfied a set of strict criteria. They yield an average paleointensity of 21.3±5.8uT, which is smaller than 31.0±3.4uT provided by Takai et al. (2002). For Aso-2 welded tuff, 11 samples from 3 sites were submitted to Thellier experiments, and 6 passed a set of pretty stringent criteria including pTRM-tail check, which is not performed by Takai et al. (2002). They give an average paleointensity of 20.2±1.5uT, which is virtually identical to 20.2±1.0uT (27 samples) given by Takai et al. (2002). Although the success rate was not good in LTD-DHT Shaw method, 2 out of 12 specimens passed the criteria, and gave 25.8±3.4uT, which is consistent with Takai et al. (2002). In addition, we obtained a reliable paleointensity from a volcanic glass in LTD-DHT Shaw method, it gives a paleointensity of 23.6 uT. It is also consitent with Takai et al. (2002). For Aso-3 welded tuff, we performed only LTD-DHT Shaw method for one specimen from one site yet. It gives a paleointensity of 43.0uT, which is higher than 31.8±3.6uT given by Takai et al. (2002). Eight sites were set for Aso-4 welded tuff

  11. Accurate paleointensities - the multi-method approach

    Science.gov (United States)

    de Groot, Lennart

    2016-04-01

    The accuracy of models describing rapid changes in the geomagnetic field over the past millennia critically depends on the availability of reliable paleointensity estimates. Over the past decade methods to derive paleointensities from lavas (the only recorder of the geomagnetic field that is available all over the globe and through geologic times) have seen significant improvements and various alternative techniques were proposed. The 'classical' Thellier-style approach was optimized and selection criteria were defined in the 'Standard Paleointensity Definitions' (Paterson et al, 2014). The Multispecimen approach was validated and the importance of additional tests and criteria to assess Multispecimen results must be emphasized. Recently, a non-heating, relative paleointensity technique was proposed -the pseudo-Thellier protocol- which shows great potential in both accuracy and efficiency, but currently lacks a solid theoretical underpinning. Here I present work using all three of the aforementioned paleointensity methods on suites of young lavas taken from the volcanic islands of Hawaii, La Palma, Gran Canaria, Tenerife, and Terceira. Many of the sampled cooling units are <100 years old, the actual field strength at the time of cooling is therefore reasonably well known. Rather intuitively, flows that produce coherent results from two or more different paleointensity methods yield the most accurate estimates of the paleofield. Furthermore, the results for some flows pass the selection criteria for one method, but fail in other techniques. Scrutinizing and combing all acceptable results yielded reliable paleointensity estimates for 60-70% of all sampled cooling units - an exceptionally high success rate. This 'multi-method paleointensity approach' therefore has high potential to provide the much-needed paleointensities to improve geomagnetic field models for the Holocene.

  12. Magnetic properties and paleointensities as function of depth in a Hawai'ian lava flow

    Science.gov (United States)

    Dekkers, M. J.; de Groot, L. V.; ter Maat, G. W.

    2013-12-01

    ) methods on six levels in the flow. Only samples from a very specific depth - the slowest cooled part at 3.9 m from the top - yielded technically acceptable IZZI-Thellier results; the obtained paleointensities (42 × 2.2 μT) are in good agreement with absolute paleointensities of flows of similar age. The pseudo-Thellier results are interpretable for more levels in the flow (between 1.5 and 4 m from the top) and yield 44.1 × 2.4 μT, within uncertainty of the IZZI-Thellier results. Our results illustrate that variations in rock-magnetic properties with depth in the flow considerably influence the suitability of samples for paleointensity experiments. The chance of obtaining a reliable paleointensity from a specific cooling unit can therefore be increased by sampling at multiple levels at different distances from the top of the flow. Evidently, the depth at which samples are taken should always be reported alongside paleointensity results. de Groot et al. (2012). AGU Fall GP43A-1122 Rubin et al. (1987). US Geol. Surv. Prof. Pap. 1350

  13. High geomagnetic intensity during the mid-Cretaceous from Thellier analyses of single plagioclase crystals.

    Science.gov (United States)

    Tarduno, J A; Cottrell, R D; Smirnov, A V

    2001-03-01

    Recent numerical simulations have yielded the most efficient geodynamo, having the largest dipole intensity when reversal frequency is low. Reliable paleointensity data are limited but heretofore have suggested that reversal frequency and paleointensity are decoupled. We report data from 56 Thellier-Thellier experiments on plagioclase crystals separated from basalts of the Rajmahal Traps (113 to 116 million years old) of India that formed during the Cretaceous Normal Polarity Superchron. These data suggest a time-averaged paleomagnetic dipole moment of 12.5 +/- 1.4 x 10(22) amperes per square meter, three times greater than mean Cenozoic and Early Cretaceous-Late Jurassic dipole moments when geomagnetic reversals were frequent. This result supports a correlation between intervals of low reversal frequency and high geomagnetic field strength. PMID:11230692

  14. Paleointensity in ignimbrites and other volcaniclastic flows

    Science.gov (United States)

    Bowles, J. A.; Gee, J. S.; Jackson, M. J.

    2011-12-01

    Ash flow tuffs (ignimbrites) are common worldwide, frequently contain fine-grained magnetite hosted in the glassy matrix, and often have high-quality 40Ar/39Ar ages. This makes them attractive candidates for paleointensity studies, potentially allowing for a substantial increase in the number of well-dated paleointensity estimates. However, the timing and nature of remanence acquisition in ignimbrites are not sufficiently understood to allow confident interpretation of paleointensity data from ash flows. The remanence acquisition may be a complex function of mineralogy and thermal history. Emplacement conditions and post-emplacement processes vary considerably between and within tuffs and may potentially affect the ability to recover ancient field intensity information. To better understand the relevant magnetic recording assemblage(s) and remanence acquisition processes we have collected samples from two well-documented historical ignimbrites, the 1980 ash flows at Mt. St. Helens (MSH), Washington, and the 1912 flows from Mt. Katmai in the Valley of Ten Thousand Smokes (VTTS), Alaska. Data from these relatively small, poorly- to non-welded historical flows are compared to the more extensive and more densely welded 0.76 Ma Bishop Tuff. This sample set enables us to better understand the geologic processes that destroy or preserve paleointensity information so that samples from ancient tuffs may be selected with care. Thellier-type paleointensity experiments carried out on pumice blocks sampled from the MSH flows resulted in a paleointensity of 55.8 μT +/- 0.8 (1 standard error). This compares favorably with the actual value of 56.0 μT. Excluded specimens of poor technical quality were dominantly from sites that were either emplaced at low temperature (600°C) temperatures does not corrupt the paleointensity signal, and additional data will be presented which explores this more fully.

  15. Paleointensity determinations from Middle Miocene volcanic rocks, Far East, Russia

    Science.gov (United States)

    Shcherbakov, Valeriy; Shcherbakova, Valentina; Zhidkov, Grigoriy; Bretstein, Yury

    2010-05-01

    Paleomagnetic and paleointensity studies of a representative collection of Middle Miocene volcanic rocks of (12.4-10.0) Ma age from Far East, Russia were carried out. A comprehensive rock magnetic investigation has been performed in order to determine the mineralogy of magnetic fraction and to identify the origin of NRM. Successful Thellier palaeointensity determinations with pTRM checks were obtained for 4 sites (33 samples). The Thellier experiments were complimented by the Wilson's express method. Values of the VDMs range from 3.1 to 7.5 (10^22 Am^2) with the mean VDM = 5.5×10^22 Am^2. A total 88 Thellier-type palaeointensity determinations were found in the World Paleointensity database for the 5-23 Ma period with the overall mean VDM = 5×10^22 Am^2. The VDM distribution is characterized by high variance from 1.5 to 12 (10^22 Am^2). No significant difference between the VDM distributions for the normal and reverse polarity intervals was revealed.

  16. Paleointensity estimates derived from non-SD recording materials: Testing the IZZI technique on MD slag and a new bootstrap procedure

    Science.gov (United States)

    Shaar, R.; Ron, H.; Tauxe, L.; Kessel, R.; Agnon, A.

    2011-12-01

    Experimental techniques to determine paleomagnetic field intensity are based on a theoretical framework that is valid only for single-domain (SD) ferromagnetic particles. Yet, most of the available materials exhibit distinctly non-SD properties. Hence, designing a robust paleointensity methodology for non-SD is a fundamental challenge in paleomagnetism. Here we test the IZZI Thellier absolute paleointensity technique on slag material that has properties of small MD. The test has two purposes: 1) to describe the characteristic non-SD patterns occurring in Arai plots, and 2) to identify the optimal approach in interpreting non-SD behavior. We produced 4 synthetic re-melted slag samples with identical magneto-mineralogical properties under field intensities of 20, 40, 60 and 80 μT. We ran three batches of IZZI paleointensity experiments on 10 specimens per samples. The IZZI experiments were designed to identify the dependency of the results on the ratio and the angle between the field used in the paleointensity experiment (BTRM) and the field in which the NRM was acquired (BNRM). The results demonstrate different types of Arai plots, systematically dependent on the angle and the proportion between BTRM and BNRM. Straight-line Arai plots occur when the two fields are parallel and equal, and seem to always give the 'true' slope. Convex curves occur when BTRM is parallel and significantly stronger than BNRM. Concave curves occur in all the other cases and yield two end-case slopes that are always different from the 'true' slope. The zigzags of the Arai plot increase with the proportion between BTRM and BNRM, and as the angle between BTRM and BNRM approaches 90°. We test the accuracy of the commonly used data analysis approach of best fitting line through a chosen segment of the Arai plot. We conclude that best fitting line in curved plots cannot provide robust paleointensity estimates. However, the two 'end-case' slopes in concave curves can provide adequate

  17. Magnetic properties and paleointensities as function of depth in a Hawaiian lava flow

    Science.gov (United States)

    de Groot, Lennart V.; Dekkers, Mark J.; Visscher, Martijn; ter Maat, Geertje W.

    2014-04-01

    outcome of paleointensity experiments largely depends on the rock-magnetic properties of the samples. To assess the relation between volcanic emplacement processes and rock-magnetic properties, we sampled a vertical transect in a ˜6 m thick inflated lava flow at Hawaii, emplaced in ˜588 AD. Its rock-magnetic properties vary as function of distance from the flow top; the observations can be correlated to the typical cooling rate profile for such a flow. The top and to a lesser extent the bottom parts of the flow cooled faster and reveal a composition of ˜TM60 in which the magnetic remanence is carried by fine-grained titanomagnetites, relatively rich in titanium, with associated low Curie and unblocking temperatures. The titanomagnetite in the slower cooled central part of the flow is unmixed into the magnetite and ülvospinel end-members as evidenced by scanning electron microscope observation. The remanence is carried by coarse-grained magnetite lamella (˜TM0) with high Curie and unblocking temperatures. The calibrated pseudo-Thellier results that can be accepted yield an average paleointensity of 44.1 ± 2.4 μT. This is in good agreement with the paleointensity results obtained using the thermal IZZI-Thellier technique (41.6 ± 7.4 μT) and a recently proposed record for Hawaii. We therefore suggest that the chance of obtaining a reliable paleointensity from a particular cooling unit can be increased by sampling lavas at multiple levels at different distances from the top of the flow combined with careful preliminary testing of the rock-magnetic properties.

  18. Is there a Link Between Geomagnetic Reversal Frequency and Paleointensity? A Bayesian Approach

    Science.gov (United States)

    Ingham, E. M.; Heslop, D.; Roberts, A. P.; Hawkins, R.

    2013-12-01

    Over the last 25 years several studies have tested for a link between geomagnetic field intensity and reversal frequency. However, despite a large increase in the number of absolute paleointensity estimates available, and improved methods for obtaining such data, no conclusive evidence has been found for such a link. Here, we employ a new tool for objectively analyzing paleomagnetic time series to investigate the possibility of a link between reversal frequency and paleointensity. Reverse Jump Markov Chain Monte Carlo analysis is a Bayesian approach to sampling for model inference in problems with variable dimension. The Reverse Jump method is applied to a quality filtered version of the global paleointensity database for the last 202 My to identify rapid changes, known as change points, in the Earth's paleointensity, and to model long-term paleointensity behavior. A transdimensional Markov Chain is used to generate a large number of paleointensity models with a variable number and position of change points. A final mean paleointensity model, along with an estimate of the associated uncertainty, is extracted from this ensemble of models. The resulting paleointensity model for 0-202 Ma contains spikes at around the ages of records that were obtained using the single silicate crystal paleointensity method. This suggests that the single silicate crystal method gives significantly different results from the more conventional whole rock paleointensity methods, which makes it difficult to include the two data types in the same analysis. When single silicate crystal data are omitted from the dataset, no large change points are identified and a stable paleointensity of 5.46 × 0.28 x 10^22 A/m^2 is consistent with the 95% confidence interval of the mean paleointensity model for the period spanning the interval from 202 to 10 My. The modeled paleointensity has no distinct variability between times of high reversal frequency, such as the late Jurassic, and low reversal

  19. Paleointensity determination of welded tuffs extruded with tephra layers: A new approach to calibration of relative paleointensity stacks

    Science.gov (United States)

    Mochizuki, N.; Fujii, S.; Hasegawa, T.; Yamamoto, Y.; Hatakeyama, T.; Okada, M.; Shibuya, H.

    2015-12-01

    For a reliable calibration of a relative paleointensity stack, we proposed a new method for direct comparison of absolute paleointensities (APIs) with relative paleointensities (RPIs) (Mochizuki et al., under review). In the analysis, APIs are directly compared with the RPIs of a RPI stack at six stratigraphic levels: three levels are based on tephrostratigraphic correlations between welded tuffs and corresponding tephra layers in the oxygen isotope stratigraphy, and the other three levels are based on paleomagnetic correlations between RPI minima and transitional geomagnetic fields. In the present study, to increase API data with tephrostratigraphic correlation, we applied the LTD-DHT Shaw paleointensity method (Tsunakawa-Shaw method) to 21 welded tuffs in Japan extruded with widespread tephra layers. We obtained mean paleointensities for 16 of the 21 welded tuffs. Since nine of the 16 welded tuffs were correlated with the tephras recognized in the oxygen isotope stratigraphy, they can be added to the API data used in the direct comparison method. Combining these API data with the reported data, we compared API data with RPIs from the PISO-1500 stack and SINT-800 stack at the 14 stratigraphic levels: eleven levels are based on tephrostratigraphic correlation and the other three levels are based on paleomagnetic correlation. RPIs of the PISO-1500 stack showed a linear relationship with the virtual axial dipole moments (VADMs) calculated from the APIs, indicating that the PISO-1500 stack has a linear relation to the axial dipole moment. PRIs from the SINT-800 stack also have a linear-like trend with the VADMs. This direct comparison method can clarify the relationship between APIs and RPIs of a RPI stack, and thus provide a reliable calibration of the RPI stack to absolute values.

  20. Microwave paleointensities indicate a low paleomagnetic dipole moment at the Permo-Triassic boundary

    Science.gov (United States)

    Anwar, Taslima; Hawkins, Louise; Kravchinsky, Vadim A.; Biggin, Andrew J.; Pavlov, Vladimir E.

    2016-11-01

    The quantity of igneous material comprising the Siberian Traps provides a uniquely excellent opportunity to constrain Earth's paleomagnetic field intensity at the Permo-Triassic boundary. There remains however, a contradiction about the strength of the magnetic field that is exacerbated by the limited number of measurement data. To clarify the geomagnetic field behavior during this time period, for the first time, a microwave paleointensity study has been carried out on the Permo-Triassic flood basalts in order to complement existing datasets obtained using conventional thermal techniques. Samples, which have been dated at ∼250 Ma, of the Permo-Triassic trap basalts from the northern extrusive (Maymecha-Kotuy region) and the southeastern intrusive (areas of the Sytikanskaya and Yubileinaya kimberlite pipes) localities on the Siberian platform are investigated. These units have already demonstrated reliable paleomagnetic directions consistent with the retention of a primary remanence. Furthermore, Scanning Electron Microscope analysis confirms the presence of iron oxides likely of primary origin. Microwave Thellier-type paleointensity experiments (IZZI protocol with partial thermoremanent magnetization checks) are performed on 50 samples from 11 sites, of which, 28 samples from 7 sites provide satisfactory paleointensity data. The samples display corresponding distinct directional components, positive pTRM checks and little or no zig-zagging of the Arai or Zijderveld plot, providing evidence to support that the samples are not influenced by lab-induced alteration or multi-domain behavior. The accepted microwave paleointensity results from this study are combined with thermal Thellier-type results from previously published studies to obtain overall estimates for different regions of the Siberian Traps. The mean geomagnetic field intensity obtained from the samples of the northern part is 13.4 ± 12.7 μT (Maymecha-Kotuy region), whereas from the southeastern part

  1. Relative paleointensity of the geomagnetic field during the past 200 ka from the West Philippine Sea and its chronological significance

    Institute of Scientific and Technical Information of China (English)

    MENG QingYong; LI AnChun; LI TieGang; JIANG FuOing; ZHOU XiaoJing

    2009-01-01

    Our rock magnetic analysis of core Ph05 from the West Philippine Sea demonstrates that the core preserves a strong, stable remanent magnetization and meets the magnetic mineral criteria for relative paleointensity (RPI) analyses. The magnetic minerals in the sequence are dominated by pseudosingle-domain magnetite, and the concentration of magnetic minerals is at the same scale. Both the conventional normalizing method and the pseudo.Thellier method were used in conjunction with the examination of the rock magnetic properties and natural remanent magnetization. Susceptibility (X), anhysteretic remnant magnetization (ARM) and saturation isothermal remnant magnetization (SIRM) were used as the natural remanent magnetization normalizer. However, coherence analysis indicated that only ARM is more suitable for paleointensity reconstruction. The age model of core is established based on oxygen isotope data and AMS14C data, which is consistent with the age model estimated from RPI records. The relative paleointensity data provide a continuous record of the intensity variation during the last 200 ka, which correlates well with the global references RPI stacks. Several prominent low paleointensity values are identified and are correlated to the main RPI minima in the SINT-200 record, suggesting that the sediments have recorded the real changes of geomagnetic field.

  2. Relative paleointensity of the geomagnetic field during the past 200 ka from the West Philippine Sea and its chronological significance

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Our rock magnetic analysis of core Ph05 from the West Philippine Sea demonstrates that the core preserves a strong, stable remanent magnetization and meets the magnetic mineral criteria for relative paleointensity (RPI) analyses. The magnetic minerals in the sequence are dominated by pseudosingle-domain magnetite, and the concentration of magnetic minerals is at the same scale. Both the conventional normalizing method and the pseudo-Thellier method were used in conjunction with the examination of the rock magnetic properties and natural remanent magnetization. Susceptibility (χ), anhysteretic remnant magnetization (ARM) and saturation isothermal remnant magnetization (SIRM) were used as the natural remanent magnetization normalizer. However, coherence analysis indicated that only ARM is more suitable for paleointensity reconstruction. The age model of core is established based on oxygen isotope data and AMS14C data, which is consistent with the age model estimated from RPI records. The relative paleointensity data provide a continuous record of the intensity variation during the last 200 ka, which correlates well with the global references RPI stacks. Several prominent low paleointensity values are identified and are correlated to the main RPI minima in the SINT-200 record, suggesting that the sediments have recorded the real changes of geomagnetic field.

  3. Geomagnetic paleointensity and direct age determination of the ISEA (M0r?) chron

    Science.gov (United States)

    Zhu, Rixiang; Hoffman, Kenneth A.; Nomade, Sébastien; Renne, Paul R.; Shi, Ruiping; Pan, Yongxin; Shi, Guanghai

    2004-01-01

    A combined paleomagnetic and geochronologic study has been conducted on an andesite lava sequence at Jianguo (Liaoning province, northeastern China). Thermal demagnetization and thermomagnetic analysis revealed that natural remanent magnetization is carried by both magnetite and hematite. Stepwise thermal demagnetization up to 675°C isolated well-defined reverse characteristic remanent magnetization (ChRM) in three time-independent lava flows with a mean direction of D/ I=179.2°/-59.7° with α95=3.0°. It also showed that a high-temperature component (>585°C) has the same ChRM direction as that of the low- to medium-temperature (ca. 170/300-585°C) components. A modified version of the Thellier-Thellier paleointensity method [Coe, J. Geophys. Res. 72 (1967) 3247-3262] with systematic partial thermoremanent magnetization checks was used for paleointensity determinations. Twelve out of 39 samples yielded reliable results in the temperature interval of 170-550°C. Virtual dipole moment values range from 3.9 to 4.7×10 22 Am 2 with an average of 4.2±0.1×10 22 Am 2. 40Ar/ 39Ar age determination on one lava flow is 116.8±3.0 Myr (2σ error, relative to Fish Canyon sanidine: 28.02±0.28 Myr). The magnetic reversed polarity with well-defined age could correspond to the 'ISEA' within the older part of the Cretaceous normal superchron (CNS), but we cannot rule out the possibility that this reversal interval could also correspond to the M0r due to many ambiguities on previous published ages on ISEA and M0r intervals as well as the new monitor age correction we applied. It also suggests that a weak magnetic field nature already documented before the CNS extended at least into the very beginning of the CNS.

  4. Paleointensity of the geomagnetic field in the Cretaceous (from Cretaceous rocks of Mongolia)

    Science.gov (United States)

    Shcherbakova, V. V.; Kovalenko, D. V.; Shcherbakov, V. P.; Zhidkov, G. V.

    2011-09-01

    A representative collection of Cretaceous rocks of Mongolia is used for the study of the magnetic properties of the rocks and for determination of the paleodirections and paleointensities H anc of the geomagnetic field. The characteristic NRM component in the samples is recognized in the temperature interval from 200 to 620-660°C. The values of H anc are determined by the Thellier-Coe method with observance of all present-day requirements regarding the reliability of such kind of results. Comparison of data in the literature on paleointensity in the Cretaceous superchron and in the Miocene supports the hypothesis of the inverse correlation between the average intensity of the paleofield and the frequency of geomagnetic reversals. The increase in the average intensities is accompanied by an appreciable increase in the variance of the virtual dipole moment (VDM). We suggest that the visible increase in the average VDM value in the superchron is due to the greater variability of VDM in this period compared to the Miocene.

  5. Revised determination of the paleointensity in the cretaceous from the collection of A.S. Bol'shakov and G.M. Solodovnikov

    Science.gov (United States)

    Shcherbakova, V. V.; Zhidkov, G. V.; Shcherbakov, V. P.

    2008-10-01

    A large volume of data on the paleointensity H an obtained by A.S. Bol’shakov and G.M. Solodovnikov is ignored in modern reconstructions because the authors did not indicate whether they used the check-point procedure for the detection of chemical alterations in rocks associated with determination of H an. The paper presents new values of H an determined by the Thellier-Coe method with the use of the checkpoint procedure from samples of the Armenian collection of Cretaceous rocks used in published studies of Bol’shakov and Solodovnikov. The new results are close to the published ones and point to a small value of the geomagnetic field in the Cretaceous, thereby corroborating Bol’shakov-Solodovnikov’s hypothesis on a low paleofield in the Mesozoic. Our study of samples of the collection studied confirms the reliability of Bol’shakov-Solodovnikov’s determinations of H an.

  6. Single Silicate Crystal Paleointensity Analyses of the ca. 2.575 Ga Great Dyke of Zimbabwe

    Science.gov (United States)

    O'Brien, T.; Tarduno, J. A.; Hofmann, A.

    2014-12-01

    Recent considerations of core thermal conductivity suggest a relatively young (less than 1 billion-year-old) age for the inner core, excluding compositional convection associated with inner core growth as a driving mechanism for an Archean geodynamo. These reconsiderations provide further motivation for studying the nature of the field when core convection was predominantly related to core mantle boundary heat flow. Here we examine the ca. 2.575 Ga Great Dyke of Zimbabwe. We rely on deep drill core samples, eliminating the otherwise pervasive effects of lightning seen in surface samples. We apply single silicate crystal paleointensity (SCP) techniques (Tarduno et al., Rev. Geophys., 2006) on feldspars separated from orthopyroxene gabbros (norites). Scanning electron microscope (SEM) analyses indicate the presence of rare sub-micron equant to slightly elongate magnetic inclusions in the feldspars. The magnetite/titanomagnetite needles commonly observed in feldspars of slowly cooled igneous rocks are rarely observed in crystals from our Great Dyke gabbro samples. Selection criteria of crystals for analyses required feldspar crystals to be free of visible multi-domain inclusions. Natural remanent magnetic intensities of ca. 1 mm-sized feldspar crystal are relatively weak (approximately 1-2 x 10-8 emu), but well within the measurement range of the University of Rochester small bore ultra-high moment resolution 2G DC SQUID magnetometer. Preliminary total thermal demagnetization experiments suggest paleofield values within 50% of those of the present-day, similar to other results that imply a relatively strong magnetic field during the late Archean. Results from Thellier analyses will be used to test this interpretation.

  7. Geomagnetic paleointensity constraints on eruption timing at the Galapagos Spreading Center

    Science.gov (United States)

    Bowles, J. A.; Ab Fatah, A.; Colman, A.; McClinton, J. T.; Sinton, J. M.; White, S. M.; Rubin, K. H.

    2011-12-01

    The intermediate-spreading-rate Galapagos Spreading Center (GSC) experiences decreasing magma supply along axis with increasing distance from the nearby Galapagos hotspot. This allows us to explore the effects of variable magma supply on eruptive frequency, size, and style. Two contrasting sites on the GSC were mapped using high-resolution swath bathymetry, submersible observations, and camera tow photography. Individual eruptive units have been identified on the basis of these data and observations, as well sample geochemistry. In order to construct an eruptive history and to make broader interpretations regarding eruptive processes, it is necessary to place relative and absolute age constraints on these units. We present age determinations derived from geomagnetic paleointensity experiments at one of the study sites, centered at ~91°55'W, where increased magma supply from the hotspot results in an axial high. Due to the near monotonic decrease in geomagnetic paleointensity over the past ~500+ years, it is possible to infer relative age and to place approximate age constraints on eruptive units on the basis of their experimentally-determined paleointensity. Four of the largest identified units have been selected as a test case. Results suggest that the youngest flow is approximately 40 ± 30 years old. This flow unit is ~5 km long by 1 km wide, centered on the rise axis. An older flow (~180 ± 30 years old), also centered along the rise axis, lies to the west and its ~7 km along-axis exposure is interrupted by a large, flat-topped seamount. A number of active hydrothermal chimneys sit atop this flow unit, the heat source for which we infer to be related to the younger flow to the east or to a more recent shallow intrusion. The oldest documented flow is roughly 400 years old and is exposed slightly off-axis to the north of the two younger flows. The paleointensity-derived flow ages are consistent with available geological constraints on relative age. Based on

  8. Paleointensities on 8 ka obsidian from Mayor Island, New Zealand

    Directory of Open Access Journals (Sweden)

    A. Ferk

    2011-07-01

    Full Text Available The 8 ka B.P. (6050 BCE pantelleritic obsidian flow on Mayor Island, Bay of Plenty, New Zealand, has been investigated using 30 samples from two sites. Due to a very high paramagnetic/ferromagnetic ratio it was not possible to determine the remanence carriers. This is despite the fact that the samples were studied intensively at low, room and high temperatures. We infer that a stable remanence within the samples is carried by single- or close to single-domain particles. Experiments to determine the anisotropy of thermoremanence tensor and the dependency on cooling rate were hampered due to alteration resulting from the repeated heating of the samples to temperatures just below the glass transition. Nonetheless, a well-defined mean paleointensity of 57.0 ± 1.0 μT, based on individual high quality paleointensity determinations, was obtained. This field value compares very well to a paleointensity of 58.1 ± 2.9 μT which Tanaka et al. (2009 obtained for 5500 BCE at a site 100 km distant. Agreement with geomagnetic field models, however, is poor. Thus, gathering more high-quality paleointensity data for the Pacific region and for the Southern Hemisphere in general to better constrain global field models is very important.

  9. Easy Absolute Values? Absolutely

    Science.gov (United States)

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  10. Paleointensity and paleodirection of the geomagnetic field in the middle Miocene: Evidence from late cenozoic volcanites of primorye

    Science.gov (United States)

    Shcherbakova, V. V.; Shcherbakov, V. P.; Bretshtein, Yu. S.; Zhidkov, G. V.

    2010-12-01

    We present the results of analyzing a representative collection of the middle Miocene 12.4-10.0 Ma basalts that compose the volcanic cover of the Shufan and Sovgavan plateaus, namely the Nikolo-L'vovsk (NL) and Sovetskaya Gavan (SG) volcanic fields. Preliminary data are obtained about the relicts of some volcanic edifices within the West and East Sikhote-Alin volcanic belts, namely the Shishlovskii, Malyshevo, and Truzhenik objects. It is established that the volcanic rocks from these localities are characterized by similar petrologic and magnetic properties. Thermal cleaning of the samples is carried out, and the coordinates of the paleomagnetic pole are determined as Λ = 190.2°E, Φ = 71.3°N for basalts of the Nokolo-L'vovsk area and Λ = 180.4°E, Φ = 71.9°N for rocks from the Sovgavan locality. These values are consistent with the data for coeval volcanics from other regions of Eurasia. Reliable determinations of the paleointensity H pal for a representative collection of samples were obtained using the Thellier method. The corresponding values of the virtual dipole moment (VDM) are almost half its present-day value. The analysis of the Miocene VDM values available from the world database revealed a low average field 5.06 × 1022 Am2 characterized by high variance σ = 2.13 × 1022 Am2 at that time. The similarity of VDM values for the Miocene characterized by frequent inversions and for the Cretaceous Superchron supports the hypothesis of the lack of a correlation between the VDM values and the frequency of geomagnetic inversions.

  11. Transitional paleointensities from Kauai, Hawaii, and geomagnetic reversal models

    Science.gov (United States)

    Bogue, Scott W.; Coe, Robert S.

    1984-01-01

    Previously presented paleointensity results from an R-N transition zone in Kauai, Hawaii, show that field intensity dropped from 0. 431 Oe to 0. 101 Oe while the field remained within 30 degree of the reversed axial dipole direction. A recovery in intensity and the main directional change followed this presumably short period of low field strength. As the reversal neared completion, the field has an intensity of 0. 217 Oe while still 40 degree from the final direction. The relationship of paleointensity to field direction during the early part of the reversal thus differs from that toward the end, a feature that only some reversal models are consistent with. For example, a model in which a standing nondipole component persists through the dipole reversal predicts only symmetric intensity patterns. In contrast, zonal flooding models generate suitably complex field behavior if multiple flooding schemes operate during a single reversal or if the flooding process is itself asymmetric.

  12. Paleointensity Estimates of Neoprotorezoic North Shore Volcanic Samples

    Science.gov (United States)

    Asefaw, H. F.; Tauxe, L.

    2014-12-01

    Tauxe and Kodama (2009) sampled 83 lava flows in the North Shore Volcanics (Keweenaw Peninsula, Michigan). Based on their demagnetization behavior (uni-vectorial and "square shouldered" demagnetization behavior), we selected 90 specimens from 28 sites and applied an alternating infield and zero-field paleointensity (IZZI) method (Tauxe and Staudigel 2004). Radiometric age constraints from U-Pb analysis of zircon has dated the sequence to the Neoprotorezoic, at approximately 1 Ga. The unblocking temperatures derived from the majority of the samples indicates that they are primarily composed of either hematite or magnetite; further analysis of their magnetic mineralogy is ongoing. Preliminary data are consistent with paleointensity estimates proposed by other investigations conducted in the surrounding region (Kulakov et al., 2013). Kulakov, E., Smirnov, A., and Diehl, J. f., 2013, Stud. Geophys. Geod., v. 57, p. 565-584. Tauxe, L., and Staudigel, H., 2004, Geochem. Geophys. Geosyst., v. 5, no. 2, p. Q02H06, doi:10.1029/2003GC000635. Tauxe, L., and Kodama, K. P., 2009, Phys. Earth Planet. Int., v. 177, p. 31-45.

  13. Absolute advantage

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2008-01-01

    textabstractA country is said to have an absolute advantage over another country in the production of a good or service if it can produce that good or service using fewer real resources. Equivalently, using the same inputs, the country can produce more output. The concept of absolute advantage can a

  14. A pseudo-Thellier relative palaeointensity record, and rock magnetic and geochemical parameters in relation to climate during the last 276 kyr in the Azores region

    NARCIS (Netherlands)

    Kruiver, P.P.; Kok, Y.S.; Dekkers, M.J.; Langereis, C.G.; Laj, C.

    2002-01-01

    In the pseudo-Thellier method for relative palaeointensity determinations (Tauxe et al. 1995) the slope of the NRM intensity left after AF demagnetization versus ARM intensity gained at the same peak field is used as a palaeointensity measure. We tested this method on a marine core from the Azores,

  15. Geomagnetic paleointensity dating of South China Sea sediments for the last 130 kyr

    Science.gov (United States)

    Xiaoqiang, Yang; Heller, Friedrich; Nengyou, Wu; Jie, Yang; Zhihua, Su

    2009-06-01

    Relative paleointensity records from the northern South China Sea, northwest Pacific Ocean were studied in two gravity piston cores. Continuous mineral magnetic and paleomagnetic measurements were made using discrete sediment samples. Detailed rock magnetic parameters, such as thermomagnetic and high-field hysteresis data, indicate that pseudo-single domain magnetite in a narrow range of grain-size and concentration is the main contributor to the remanent magnetization. The uniform magnetic mineralogy meets the commonly accepted criteria for establishing relative paleointensity records. The relative paleointensity (RPI) curves were constructed by normalizing the natural remanent magnetization (NRM) with isothermal remanent magnetization (IRM), both in the 20-60 mT demagnetization state. Dating constraints have been provided by radiocarbon ages in the upper 400 cm of both cores. Furthermore, we have correlated our paleointensity records with NAPIS-75, S.Atlantic-1089, Sint-200 and NOPAPIS-250 to determine the chronological RPI framework for the South China Sea (SCS-PIS). Although some temporal offsets of paleointensity features between the different records have been recognized, their similar shape suggests that relative paleointensity on the 10 3-10 4 year scale is globally coherent and can provide an age framework for sediments independent of δ18O ages.

  16. Absolute beginners

    OpenAIRE

    Costa, Carlos Casimiro da; Costa, Jacinta Casimiro da

    2012-01-01

    Tomorrow, I m recovering my Thursday child as an absolute beginner , Transporting you to the essential touch of surface skin and space, Only for you, i do not regret, looking for education in a materia set. My love is your love , my materiality is you making things, The legacy of our ethnography, craftsmen s old and disappear, make me strong hard feelings, Recovering experiences and knowledge sprinkled in powder of stone, wood and metal ( ) reflecting in your dirty face the ...

  17. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  18. Saw-toothed pattern of relative paleointensity records and cumulative viscous remanence

    NARCIS (Netherlands)

    Kok, Yvo S.; Tauxe, Lisa

    2002-01-01

    Several studies of relative paleointensity data derived from marine sediments spanning the last 4 Myr display an asymmetrical "saw-toothed" pattern. Polarity reversals of the geomagnetic field are associated with low points in paleofield intensity, preceded by a long-term progressive decay of the fi

  19. Climatic influence in NRM and 10 Be-derived geomagnetic paleointensity data

    NARCIS (Netherlands)

    2001-01-01

    One can determine geomagnetic paleointensities from natural remanent magnetizations (NRM) and by inverting production rates of cosmogenic isotopes such as 10 Be and 14 C. Recently, two independently derived 200-kyr stacks [Y. Guyodo, J.-P. Valet, Relative variations in geomagnetic intensity from sed

  20. High paleointensities for the Canary Islands constrain the Levant geomagnetic high

    NARCIS (Netherlands)

    de Groot, Lennart V.; Béguin, Annemarieke; Kosters, Martha E.; van Rijsingen, Elenora M.; Struijk, Erzsébet L.M.; Biggin, Andrew J.; Hurst, Elliot A.; Langereis, Cor G.; Dekkers, Mark J.

    2015-01-01

    Understanding the behavior of enigmatic geomagnetic traits such as the Levant intensity high is currently challenged by a lack of full vector records of regional variations in the geomagnetic field. Here we apply the recently proposed multi-method paleointensity approach to a suite of 19 lavas from

  1. Saw-toothed pattern of sedimentary paleointensity records explained by cumulative viscous remanence

    NARCIS (Netherlands)

    Kok, Yvo S.; Tauxe, Lisa

    2001-01-01

    The relative paleointensity of the earth's magnetic field from ODP Site 851 has been characterized by progressive decay w x towards polarity reversals, followed by sharp recovery of pre-reversal values 1 . We resampled the Gilbert-Gaub reversal boundary of this deep-sea core, and show that during de

  2. A relative paleointensity record of the geomagnetic field since 1.6 Ma from the North Pacific

    Science.gov (United States)

    Yamazaki, Toshitsugu; Kanamatsu, Toshiya

    2007-07-01

    A paleomagnetic study was conducted on a sediment core KR0310-PC1 taken from the central North Pacific in order to obtain a relative paleointensity record in the Matuyama chron from this region. The core reached to about 1.6 Ma. The age control is based on the correlation of the S ratio ( S -0.1T) variations with a global oxygen-isotope stack. Isothermal remanent magnetization (IRM) was used as the normalizer of the relative paleointensity estimation; anhysteretic remanent magnetization (ARM) was not adopted because ARM is sensitive to magnetostatic interaction among magnetic particles, which is evidenced in these sediments by an inverse correlation between the ratio of ARM to saturation IRM (SIRM) and SIRM without significant magnetic grain-size changes. For the last 350 kyrs, the record of core NGC65, which was obtained at practically the same site as KR0310-PC1 and covers the Brunhes chron (Yamazaki, 1999), was incorporated because the upper part of KR0310-PC1 was physically disturbed. In the record of NGC65/KR0310-PC1, the average paleointensity in the late Matuyama chron is not lower than that during the Brunhes chron, which does not support the conclusion of Valet et al. (2005) based on their Sint-2000 stack. A spectral analysis on the NGC65/KR0310-PC1 paleointensity record shows a power at the ˜100 kyr eccentricity period. The relative paleointensity and magnetic properties of NGC65/KR0310-PC1 were compared with those of MD982185 from the western equatorial Pacific (Yamazaki and Oda, 2002, 2005). The two sites belong to different oceanographic regimes. Coherent variations in the relative paleointensity despite incoherent changes in the magnetic properties suggest that rock-magnetic contamination to the relative paleointensity is small, if any, and the ˜100 kyr period in the relative paleointensity records would reflect the geomagnetic field behavior.

  3. Geomagnetic field variations during the last 400 kyr in the western equatorial Pacific: Paleointensity-inclination correlation revisited

    Science.gov (United States)

    Yamazaki, T.; Kanamatsu, T.; Mizuno, S.; Hokanishi, N.; Gaffar, E. Z.

    2008-12-01

    A paleomagnetic study was conducted on four piston cores newly obtained from the West Caroline Basin in the western equatorial Pacific in order to investigate variations in paleointensity and inclination during the last 400 kyr. An inclination-intensity correlation was previously reported in this region using giant piston cores, but the quality of the paleomagnetic data of the younger end, the last ca. 300 kyr, was needed to be checked because the upper part of the giant piston cores could suffer from perturbation by oversampling. Age control is based on the oxygen-isotope ratios for one core and inter-core correlation using relative paleointensity for other cores. The mean inclinations of the four cores show negative inclination anomalies ranging from -5.2 to -11.2 degree. The western equatorial Pacific is documented as a region of a large negative inclination anomalies, and the observed values are comparable to those expected from the time-averaged field (TAF) models [Johnson and Constable, 1997; Hatakeyama and Kono, 2002]. Stacked curves of paleointensity and inclination were constructed from the four cores. It was confirmed that geomagnetic variations on the order of 10 to 100 kyrs occur in inclination as well as paleointensity. A cross-correlation analysis showed that significant in-phase correlation occurs between intensity and inclination for periods longer than about 25 kyr, and power spectra of both paleointensity and inclination variations have peaks at ~100 kyr periods. The regional paleointensity stack with higher resolution than the Sint-800 stack [Guyodo and Valet, 1999] should be useful for paleointensity-assisted chronostratigraphy.

  4. Teaching Absolute Value Meaningfully

    Science.gov (United States)

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  5. Relative paleointensity of the geomagnetic field during the past 0.8 Ma from Nihewan Basin, Hebei Province, China

    Institute of Scientific and Technical Information of China (English)

    WANG Yong; CHI Zhenqing; LEE Tehquei; MIN Longrui; CHU Huiyan

    2004-01-01

    We conducted a detailed rock magnetic study on upper 80 m of Jing'erwa core from the Nihewan basin. The results indicate that the sediments from Jing'erwa core are suitable for relative paleointensity study, and anhysteretic remanent magnetization (ARM) can be used as the normalization parameter of the natural remanent magnetization (NRM). Our relative paleointensity data of upper 80 m of Jing'erwa core provide a continuous record of the intensity variation during the last 0.8 Ma, which correlates well with the results from marine sediments cores in the Pacific Ocean. This means that the sediments records are reliable for relative paleointensity of Earth's magnetic field, and suggests that these sediments have recorded the real changes of geomagnetic field, which would provide a new method for regional stratigraphic correlation.

  6. Saw-toothed pattern of relative paleointensity records and cumulative viscous remanence

    Science.gov (United States)

    Kok, Yvo S.; Tauxe, Lisa

    1996-01-01

    Several studies of relative paleointensity data derived from marine sediments spanning the last 4 Myr display an asymmetrical "saw-toothed" pattern. Polarity reversals of the geomagnetic field are associated with low points in paleofield intensity, preceded by a long-term progressive decay of the field and followed by a rapid post-transitional recovery [1-3]. Since similar behavior is observed in far-flung sites whose rock magnetic records are different, it is argued that the world-wide "saw-toothing" represents geomagnetic field behavior[3]. We present an alternative explanation, calling on the effect of "hard" viscous remanence.

  7. Eosinophil count - absolute

    Science.gov (United States)

    Eosinophils; Absolute eosinophil count ... the white blood cell count to give the absolute eosinophil count. ... than 500 cells per microliter (cells/mcL). Normal value ranges may vary slightly among different laboratories. Talk ...

  8. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  10. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  11. Absolute Pitch on Music

    OpenAIRE

    Çuhadar, C.Hakan

    2008-01-01

    Musicians are debated people in the academic circles with the claim of they have both various characteristics and different cognitive personalities on the analogy those other people. One of these different characteristics is absolute pitch ability. Absolute pitch (AP) is a cognitive ability which can be characterized as to identify any tones (labeling) at a given pitch without using any external references. According to the different studies which were held in different times, the prevalence ...

  12. Absolute polarimetry at RHIC

    OpenAIRE

    Okada, H.; Alekseev, I.; Bravar, A; Bunce, G.; Dhawan, S.; Eyser, K. O.; Gill, R; Haeberli, W.; Huang, H.; Jinnouchi, O.; Makdisi, Y.; Nakagawa, I.; Nass, A.; Saito, N; Stephenson, E.

    2007-01-01

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy of $\\Delta P_{beam}/P_{beam} < 5%$. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detector...

  13. Weaker axially dipolar time-averaged paleomagnetic field based on multidomain-corrected paleointensities from Galapagos lavas.

    Science.gov (United States)

    Wang, Huapei; Kent, Dennis V; Rochette, Pierre

    2015-12-01

    The geomagnetic field is predominantly dipolar today, and high-fidelity paleomagnetic mean directions from all over the globe strongly support the geocentric axial dipole (GAD) hypothesis for the past few million years. However, the bulk of paleointensity data fails to coincide with the axial dipole prediction of a factor-of-2 equator-to-pole increase in mean field strength, leaving the core dynamo process an enigma. Here, we obtain a multidomain-corrected Pliocene-Pleistocene average paleointensity of 21.6 ± 11.0 µT recorded by 27 lava flows from the Galapagos Archipelago near the Equator. Our new result in conjunction with a published comprehensive study of single-domain-behaved paleointensities from Antarctica (33.4 ± 13.9 µT) that also correspond to GAD directions suggests that the overall average paleomagnetic field over the past few million years has indeed been dominantly dipolar in intensity yet only ∼ 60% of the present-day field strength, with a long-term average virtual axial dipole magnetic moment of the Earth of only 4.9 ± 2.4 × 10(22) A ⋅ m(2). PMID:26598664

  14. Relative paleointensity record during the last 800 ka from the equatorial Indian Ocean: Implication for relationship between inclination and intensity variations

    Science.gov (United States)

    Suganuma, Y.; Yamazaki, T.; Kanamatsu, T.; Hokanishi, N.

    2008-02-01

    Paleomagnetic and rock magnetic investigations were carried out on three sediment cores taken from the Ninetyeast Ridge, the eastern equatorial Indian Ocean. The cores are 4.1-10.2 m long and cover the last 270-790 ka with average sedimentation rates of 1.3-1.9 cm/ka. Generally stable demagnetization behaviors and relatively uniform rock magnetic characteristics allowed us to reconstruct relative paleointensity records (NRM30mT/IRM30mT) for each core. The relative paleointensity records showed a beneficial agreement with each other except for the uppermost parts of the cores, and patterns similar to the Sint-800 paleointensity stack and other relative paleointensity records. Spectral analyses of the relative paleointensity records revealed a dominant periodicity at about 100 ka, but not for the normalizer and other rock magnetic proxies. These results suggested that the 100 ka periodicity in the paleointensity records during the Brunhes Chron would not be caused by sedimentological effects. The mean inclination values of the three cores were close to the expected hypothetical geocentric axial dipole (GAD) direction, which implies that ˜5-10° of negative inclination anomaly (ΔI) is centered at the western equatorial Pacific Ocean, and not extended to the eastern equatorial Indian Ocean. A comparison between the relative paleointensity variation and ΔI amplitude between the eastern equatorial Indian Ocean and the western equatorial Pacific Ocean suggests that changes of the GAD intensity control the relative contribution of the persistent nondipole components and produces the inclination variation.

  15. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  16. MSP-Tool: a VBA-based software tool for the analysis of multispecimen paleointensity data

    Directory of Open Access Journals (Sweden)

    Marilyn Wilhelmina Leonora Monster

    2015-12-01

    Full Text Available The multispecimen protocol (MSP is a method to estimate the Earth’s magnetic field’s past strength from volcanic rocks or archeological materials. By reducing the amount of heating steps and aligning the specimens parallel to the applied field, thermochemical alteration and multi-domain effects are minimized. We present a new software tool, written for Microsoft Excel 2010 in Visual Basic for Applications (VBA, that evaluates paleointensity data acquired using this protocol. In addition to the three ratios (standard, fraction-corrected and domain-state-corrected calculated following Dekkers and Böhnel (2006 and Fabian and Leonhardt (2010 and a number of other parameters proposed by Fabian and Leonhardt (2010, it also provides several reliability criteria. These include an alteration criterion, whether or not the linear regression intersects the y axis within the theoretically prescribed range, and two directional checks. Overprints and misalignment are detected by isolating the remaining natural remanent magnetization (NRM and the partial thermoremanent magnetization (pTRM gained and comparing their declinations and inclinations. The NRM remaining and pTRM gained are then used to calculate alignment-corrected multispecimen plots. Data are analyzed using bootstrap statistics. The program was tested on lava samples that were given a full TRM and that acquired their pTRMs at angles of 0, 15, 30 and 90° with respect to their NRMs. MSP-Tool adequately detected and largely corrected these artificial alignment errors.

  17. Rock magnetic and paleointensity results from Mesozoic baked contacts of Armenia

    Science.gov (United States)

    Shcherbakova, V. V.; Perrin, M.; Shcherbakov, V. P.; Pavlov, V. E.; Ayvaz'yan, A.; Zhidkov, G. V.

    2009-01-01

    Samples were obtained from three baked contacts and one lava flow along the upper Turonian-lower Coniacian Tovuz section, two baked contacts along the upper Coniacian-lower Santonian Paravakar section in the northern part of Armenia, and three baked contacts along the Titonian-Valanginian Kafan section in southern Armenia. A total of 130 samples were studied. Updated mean paleomagnetic poles were calculated for the Upper Cretaceous Tovuz-Paravakar sections (65.6°N, 162.2°E, A95 = 4.3, paleolatitude = 27.0 ± 3.4°) and the Upper Jurassic-Lower Cretaceous Kafan section (61.7°N, 158.9°E, A95 = 4.8°, paleolatitude = 24.7 ± 3.8°). Paleointensity determinations could be estimated from two of the upper Cretaceous and three of the Upper Jurassic-Lower Cretaceous baked contacts, corresponding to a 30% success rate. The mean virtual dipole moments obtained were low (1.7-5.5 × 1022 A m2), which is in agreement with data published by Bol'shakov and Solodovnikov (1981a, 1983) for the same sections (3.0-4.4 × 1022 A m2). Our results support the hypothesis of the Mesozoic Dipole Low, even though the overall data are widely dispersed.

  18. Estimating the variations in paleointensity from the Siberian traps of Maymecha-Kotui and Norilsk regions

    Science.gov (United States)

    Scherbakova, V. V.; Zhidkov, G. V.; Latyshev, A. V.; Scherbakov, V. P.

    2013-07-01

    The results of determining the paleointensity of the Siberian traps sampled from the Kotui sequence, Truba ravine, Onkuchak Suite, and dated to Permian-Triassic are presented. Most of the H anc values for separate lava flows are significantly lower than the values of the present geomagnetic field at the observation point (approximately 50 μT). This is consistent with the known conclusion that the intensity of the geomagnetic field at the Permian-Triassic boundary was lower by a factor of two to three lower than its present value. We carried out the comparative analysis of the behavior of H an and VDM for two trap sequences (Kotui (the Onkuchak Suite) and Norilsk) from the standpoint of the eruptive pulse hypothesis. In both sections, the average VDM values and their dispersion are similar. For comparison, similar analysis of the VDM behavior is conducted for the Brunhes epoch and Miocene in the interval of 5-10 Ma. It is hypothesized that during the three considered periods, namely, the eruption of the Siberian traps, in the Brunhes epoch, and in Miocene (in the interval of 5-10 Ma), the time behavior of the geomagnetic field was close to a stationary stochastic process.

  19. MSP-Tool: a VBA-based software tool for the analysis of multispecimen paleointensity data

    Science.gov (United States)

    Monster, Marilyn; de Groot, Lennart; Dekkers, Mark

    2015-12-01

    The multispecimen protocol (MSP) is a method to estimate the Earth's magnetic field's past strength from volcanic rocks or archeological materials. By reducing the amount of heating steps and aligning the specimens parallel to the applied field, thermochemical alteration and multi-domain effects are minimized. We present a new software tool, written for Microsoft Excel 2010 in Visual Basic for Applications (VBA), that evaluates paleointensity data acquired using this protocol. In addition to the three ratios (standard, fraction-corrected and domain-state-corrected) calculated following Dekkers and Böhnel (2006) and Fabian and Leonhardt (2010) and a number of other parameters proposed by Fabian and Leonhardt (2010), it also provides several reliability criteria. These include an alteration criterion, whether or not the linear regression intersects the y axis within the theoretically prescribed range, and two directional checks. Overprints and misalignment are detected by isolating the remaining natural remanent magnetization (NRM) and the partial thermoremanent magnetization (pTRM) gained and comparing their declinations and inclinations. The NRM remaining and pTRM gained are then used to calculate alignment-corrected multispecimen plots. Data are analyzed using bootstrap statistics. The program was tested on lava samples that were given a full TRM and that acquired their pTRMs at angles of 0, 15, 30 and 90° with respect to their NRMs. MSP-Tool adequately detected and largely corrected these artificial alignment errors.

  20. LIBS, EDXRF analysis and Paleointensity measurements on ancient pottery samples recently excavated in Tamilnadu, India

    International Nuclear Information System (INIS)

    Ancient ceramics are the most abundant artifacts that have been studied to improve our knowledge of past societies. Archaeological research based on the examination of ware shape, style, color, decoration and overall fabric; provide a wealth of information concerning typological and functional issues, chronology and provenance. In recent years, the characterization of ancient pottery to determine its provenance has involved the development, exploration, and testing of a large number of analytical techniques in order to compile and extract relevant compositional information. Spectroscopic and archaeomagnetic dating technique is the important scientific tool to find out the elemental analysis as well as to predict the age of the artifacts. The rich quantity of clay minerals especially iron oxides were found in bricks which help for predicting the ancient geomagnetic field intensity. In the present work, Laser Induced Breakdown Spectroscopy (LIBS), Energy Dispersive X-Ray Fluorescence (EDXRF) and archaeomagnetic dating studies have been performed on archaeological pottery samples collected from Sankari Durg archaeological site to estimate the ancient geomagnetic field intensity measurement. The mean paleointensity value of the sample is found to be 45.2 ± 0.9 μT and the estimated archaeomagnetic dating of Sankari Durg pottery samples are 18th Century; it has good agreement with the age predicted by the archaeologist. (author)

  1. Correlation of Late Pleistocene Terrestrial Climate Variation From Mono Lake, USA, With Global Records Using Relative Paleointensity

    Science.gov (United States)

    Zimmerman, S.; Hemming, S.; Kent, D.

    2004-12-01

    In order to assess different models of global climate variation, it is crucial to be able to accurately correlate terrestrial climate records with each other and with marine climate records. This problem is especially challenging in intervals older than 30 kyr, when problems with accuracy and precision of 14C ages become significant. Recently published stacks of global, high-resolution variation in intensity of Earth's past magnetic field (North and South Atlantic PaleoIntensity Stacks, NAPIS and SAPIS) enable correlation of high-quality terrestrial records of paleointensity with the GISP2 timescale. The lacustrine sediments of the Wilson Creek Formation (Mono Basin, CA) are known to be excellent recorders of Pleistocene climate and geomagnetic field variation, and are the type locality for the Mono Lake paleomagnetic excursion (MLE). Here we present rock magnetic analyses showing that the sediments also fit the criteria required for good recorders of paleomagnetic intensity, with a magnetic fraction dominated by fine-grained magnetite with concentration variation lakes of the Great Basin have been shown to be strongly controlled by the 100 ka cycle, and so we infer lake transgression over the Wilson Creek site at the M.I.S. 5/4 boundary, fixing the maximum age of sediment deposition. We then use distinctive features of the Mono and global paleo-intensity records to refine the correlation, resulting in an age of 68 ka for the oldest sediments, and 40 ka for the MLE, coeval with the Laschamp excursion. Finally, we compare climatic proxies measured at Mono to regional and global records, with major changes in glacial proxies at M.I.S. 4/3 boundary and evidence for low lake levels at the time of Heinrich events.

  2. ABSOLUTE POLARIMETRY AT RHIC.

    Energy Technology Data Exchange (ETDEWEB)

    OKADA; BRAVAR, A.; BUNCE, G.; GILL, R.; HUANG, H.; MAKDISI, Y.; NASS, A.; WOOD, J.; ZELENSKI, Z.; ET AL.

    2007-09-10

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy Of {Delta}P{sub beam}/P{sub beam} < 5%. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in the RHIC-ring in 2004. This system features proton-proton elastic scattering in the Coulomb nuclear interference (CNI) region. Precise measurements of the analyzing power A{sub N} of this process has allowed us to achieve {Delta}P{sub beam}/P{sub beam} = 4.2% in 2005 for the first long spin-physics run. In this report, we describe the entire set up and performance of the system. The procedure of beam polarization measurement and analysis results from 2004-2005 are described. Physics topics of AN in the CNI region (four-momentum transfer squared 0.001 < -t < 0.032 (GeV/c){sup 2}) are also discussed. We point out the current issues and expected optimum accuracy in 2006 and the future.

  3. Absolute polarimetry at RHIC

    CERN Document Server

    Okada, H; Bravar, A; Bunce, G; Dhawan, S; Eyser, K O; Gill, R; Haeberli, W; Huang, H; Jinnouchi, O; Makdisi, Y; Nakagawa, I; Nass, A; Saitô, N; Stephenson, E; Sviridia, D; Wise, T; Wood, J; Zelenski, A

    2007-01-01

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy of $\\Delta P_{beam}/P_{beam} < 5%$. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in the RHIC-ring in 2004. This system features \\textit{proton-proton} elastic scattering in the Coulomb nuclear interference (CNI) region. Precise measurements of the analyzing power $A_N$ of this process has allowed us to achieve $\\Delta P_{beam}/P_{beam} =4.2%$ in 2005 for the first long spin-physics run. In this report, we describe the entire set up and performance of the system. The procedure of beam polarization measurement and analysis results from 2004-2005 are described. Physics topics of $A...

  4. Optical tweezers absolute calibration

    CERN Document Server

    Dutra, R S; Neto, P A Maia; Nussenzveig, H M

    2014-01-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past fifteen years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spo...

  5. Estimating Absolute Site Effects

    Energy Technology Data Exchange (ETDEWEB)

    Malagnini, L; Mayeda, K M; Akinci, A; Bragato, P L

    2004-07-15

    The authors use previously determined direct-wave attenuation functions as well as stable, coda-derived source excitation spectra to isolate the absolute S-wave site effect for the horizontal and vertical components of weak ground motion. They used selected stations in the seismic network of the eastern Alps, and find the following: (1) all ''hard rock'' sites exhibited deamplification phenomena due to absorption at frequencies ranging between 0.5 and 12 Hz (the available bandwidth), on both the horizontal and vertical components; (2) ''hard rock'' site transfer functions showed large variability at high-frequency; (3) vertical-motion site transfer functions show strong frequency-dependence, and (4) H/V spectral ratios do not reproduce the characteristics of the true horizontal site transfer functions; (5) traditional, relative site terms obtained by using reference ''rock sites'' can be misleading in inferring the behaviors of true site transfer functions, since most rock sites have non-flat responses due to shallow heterogeneities resulting from varying degrees of weathering. They also use their stable source spectra to estimate total radiated seismic energy and compare against previous results. they find that the earthquakes in this region exhibit non-constant dynamic stress drop scaling which gives further support for a fundamental difference in rupture dynamics between small and large earthquakes. To correct the vertical and horizontal S-wave spectra for attenuation, they used detailed regional attenuation functions derived by Malagnini et al. (2002) who determined frequency-dependent geometrical spreading and Q for the region. These corrections account for the gross path effects (i.e., all distance-dependent effects), although the source and site effects are still present in the distance-corrected spectra. The main goal of this study is to isolate the absolute site effect (as a function of frequency

  6. A high-resolution paleointensity stack of the past 14 to 68 ka from Black Sea sediments

    Science.gov (United States)

    Nowaczyk, N. R.; Frank, U.; Kind, J.; Arz, H. W.

    2013-12-01

    Detailed paleo- and mineral magnetic analyses of a sediment composite record from the southeastern Black Sea yielded a high-resolution, well-dated paleointensity record. Though hampered by some larger hiatuses in some cores, and contaminated by diagenetically formed greigite, the paleomagnetic composite record obtained from the preserved primary detrital magnetite phase reflects a highly dynamic geomagnetic field during the last glacial period. Relative variations of paleointensity inferred from the sediments' magnetisations were converted into a record of the virtual axial dipole moment (VADM). Lowest VADM values are linked with the Laschamp (0.50×1022 Amat 41.0 ka), the Norwegian-Greenland-Sea (1.5×1022 Amat 64.5 ka), and the Mono Lake (3.0×1022 Amat 34.5 ka) geomagnetic excursions. The fully reversed field during the Laschamp excursion exhibits a VADM of 2.0×1022 Am which is more than 25% of the present day axial dipole moment (7.628×1022 Am). Rates of change calculated from the Black Sea VADM record also give some information on how to assess the global decay of the present-day geomagnetic field, which is significantly enhanced in the area of the South Atlantic Anomaly. Comparison with provided ΔC14 and 10Be records confirm, partly in the very detail, the non-linear anti-correlation of geomagnetic field intensity and the production of cosmogenic radionuclides in the Earth's upper atmosphere. However, discrepancies in the timing of lows and highs in the compiled records points out that the combination of different data sets from different archives remains a challenge.

  7. Be Resolute about Absolute Value

    Science.gov (United States)

    Kidd, Margaret L.

    2007-01-01

    This article explores how conceptualization of absolute value can start long before it is introduced. The manner in which absolute value is introduced to students in middle school has far-reaching consequences for their future mathematical understanding. It begins to lay the foundation for students' understanding of algebra, which can change…

  8. ROE Absolute Sea Level Changes

    Data.gov (United States)

    U.S. Environmental Protection Agency — This raster dataset represents changes in absolute sea level along U.S. coasts from 1993 to 2014. Data were provided by the University of Colorado at Boulder (2015)...

  9. Absolute transition probabilities of phosphorus.

    Science.gov (United States)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  10. Absolute luminosity measurements at LHCb

    CERN Document Server

    Hopchev, Plamen

    2011-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC running at a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer'' scan method a novel technique has been developed which makes use of direct imaging of the individual beams using both proton-gas and proton-proton interactions. The beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. We describe both methods and compare the two results. In addition, we present the techniques used to transport the absolute luminosity measurement ...

  11. Rock magnetic properties and relative paleointensity stack for the last 300 ka based on a stratigraphic network from the subtropical and subantarctic South Atlantic

    Science.gov (United States)

    Hofmann, Daniela I.; Fabian, K.

    2007-08-01

    We present a detailed study of natural remanence and rock magnetic properties of eight sediment cores from a South-North profile across the subtropical front (STF) in the South Atlantic, which previously have been combined into a stratigraphic network. Based on these measurements, we construct a first relative paleointensity (RPI) stack for the central South-Atlantic (SAS-300) covering the last 300 ka. The degree of down-core homogeneity of magnetic mineral concentration as well as magnetic mineral content and grain sizes vary between all cores and are quantified by high-resolution rock magnetic measurements. In the cores north of and close to the STF, the magnetic remanence is mainly carried by magnetite. The cores in the south also contain a high coercive mineral fraction. Based on a linear model of the sediment matrix, we propose to apply principal component analysis (PCA) of natural remanent magnetization (NRM), anhysteretic, and isothermal remanent magnetization (ARM and IRM) to determine a homogeneity interval, where remanences are only affected by a single environmental signal. This reduces lithologic and climatic influence upon the relative paleointensity record. For our data set PCA indicates that all remanences in the 30 mT to 80 mT demagnetization interval are dominated by a single environmental influence. Single core RPI estimates are then obtained by normalizing the NRM fraction in this homogeneity interval with respect to either IRM, ARM in the same interval, or by κ. By direct averaging, we obtain the stack SAS-300, which is compared to other paleointensity series such as Sint-800, or the RPI records from ODP Sites 1089 (Subantarctic South Atlantic) and 983 (Gardar Drift). The detailed documentation of environmental influences combined with the presentation of seven different recordings of the same geomagnetic signal allows to connect southern and northern hemisphere RPI data, also with respect to possible common environmental distortions.

  12. New Insights on Long Term Geomagnetic Moment Variation from Cosmogenic Nuclide and Paleointensity Signatures along Ocean Sediment Cores.

    Science.gov (United States)

    Thouveny, N.; Bourles, D. L.; Valet, J. P.; Bassinot, F. C.; Ménabréaz, L.; Simon, Q.; Demory, F.; Valery, G.; Vidal, L.; Beaufort, L.; de Garidel-Thoron, T.

    2015-12-01

    Some numerical and experimental simulations suggest that precession might supply enough power to influence planetary dynamos. The demonstration of a causal relationship between the Earth's orbital motion and variations of the geomagnetic field intensity, would open interesting perspective for modelling the past and future geomagnetic field behaviour and its eventual relationships to past and future orbitally constrained, climatic changes. Although pristine geomagnetic signals can be extracted by filtering and stacking multiple normalized intensity records, the reconstruction of high resolution geomagnetic field variations still raises questions. Namely, significant variance at orbital frequencies in relative paleointensity (RPI) records are generally considered as clues of residual contamination by paleoclimatically induced variations of magnetic carriers size ranges or mineralogy. Such questions can be adressed using other indicators of the geomagnetic dipole moment variation, such as the cosmogenic production modulated by the magnetospheric shielding. During the MAGORB project (ANR-09-BLAN-053-001) cosmogenic nuclide geochemistry, d18O, and paleomagnetic records were constructed along thick clayey-carbonate sequences deposited in the equatorial pacific and indian oceans over the last million of years. Authigenic 10Be/9Be ratio and RPI variations generally exhibit similar ranges of oscillations. However significant offsets appear between some RPI lows and their corresponding 10Be/9Be peaks, suggesting delayed lock-in of the remanent magnetization. After transfer on time scales the new geomagnetic moment series can be compared with the PISO-1500 and SINT-2000 stacks, and with the 10Be ice core record of EPICA Dome C. These new authigenic 10Be/9Be ratio records provide new opportunities to: 1) assess the validity of high resolution RPI records, 2) evaluate address the question of the presence of orbital periods in the paleo-field geomagnetic spectrum, and 3) to

  13. Android Apps for Absolute Beginners

    CERN Document Server

    Jackson, Wallace

    2011-01-01

    Anybody can start building simple apps for the Android platform, and this book will show you how! Android Apps for Absolute Beginners takes you through the process of getting your first Android applications up and running using plain English and practical examples. It cuts through the fog of jargon and mystery that surrounds Android application development, and gives you simple, step-by-step instructions to get you started.* Teaches Android application development in language anyone can understand, giving you the best possible start in Android development * Provides simple, step-by-step exampl

  14. Relative paleointensity of the geomagnetic field over the last 4,500 years BP from sediment cores of Laguna Chaltel (Patagonia, Argentina)

    Science.gov (United States)

    Gogorza, C. G.; Irurzun, M. A.; Sinito, A. M.; Aldana, M.; Fey, M.; Ohlendorf, C.; Zolitschka, B.

    2013-05-01

    One motivation to investigate the magnetism of rocks is to study the behaviour of Earth's magnetic field of the past. The magnetic field is a vector field, having both direction and intensity. A complete understanding of it requires the study of all vector properties. However, paleointensity determinations are much more difficult than directions alone. This is one reason why the majority of paleomagnetic studies is concerned only with the directional variability of the magnetic field. Four short gravity cores from Laguna Chaltel in Patagonia, Argentina (49° 57'S, 71° 06'W) have been used to estimate the regional geomagnetic paleointensity. Measurements of intensity and directions of Natural Remanent Magnetization (NRM), magnetic susceptibility (k), isothermal remanent magnetization (IRM), saturation isothermal remanent magnetization (SIRM), as well as back field and anhysteretic remanent magnetization at 100 mT (ARM100mT) were performed and associated parameters calculated (ARM100mT/k, SIRM/ ARM100mT). In order to identify the magnetic mineralogy of the samples, IRM curves of a group of pilot samples were decomposed applying a Direct Signal Analysis (DSA) (Aldana et al., 2011). Results indicate the presence of magnetite, with logB1/2=1.8 and a relative proportion of 80%. Two other magnetic phases are observed at lower and higher logB1/2 values, probably greigite and goethite, respectively. DSA also indicates that the relative proportion of these minerals is the same in all samples analyzed. Studies also show that the magnetic grain size varies between 1 and 8 μm and that their concentration is between 0.01 and 0.08%. This range of the studied parameters indicates that our samples are suitable for paleointensity studies. The remanent magnetization at 15 mT (NRM15mT) has been normalized using the anhysteretic remanent magnetization at 15 mT (ARM15 mT), the saturation of isothermal remanent magnetization at 15 mT (SIRM15mT) and low field magnetic susceptibility (k

  15. Late Quaternary paleomagnetic secular variation, relative paleointensity, and environmental magnetism from Cascade Lake, Brooks Range, Arctic Alaska

    Science.gov (United States)

    Steen, D. P.; Kaufman, D. S.; Stoner, J. S.; Reilly, B. T.

    2015-12-01

    Two sediment cores from Cascade Lake (68.38°N, 154.60°W), Arctic Alaska were selected for paleomagnetic analysis to compare 14C age control with paleomagnetic secular variation (PSV) and relative paleointensity (RPI) age control derived from field models and other local sedimentary records. Rock magnetic experiments were performed to quantify variability in magnetic properties and to infer sediment sourcing during the late Quaternary. U-channels were studied through AF demagnetization of the natural remanent magnetization, and laboratory-induced magnetizations including anhysteretic remanent magnetization (ARM) acquisition, ARM demagnetization, and isothermal remanent magnetization (IRM). Maximum angular deviation values average coercivity component that increases up core. Average inclinations are within 4° of the expected geocentric axial dipole, and major inclination features can be correlated across the two cores. Correlation of inclination changes with the Burial Lake record, 200 km to the west (Dorfman, 2013, unpub. thesis), indicates that the Cascade Lake sedimentary sequence overlying the basal diamicton likely spans at least 16 ka. Cascade Lake sediments may be suitable for RPI estimation using the ARM or IRM as a normalizer, following a more detailed examination of magnetic properties. A systematic offset between the Cascade Lake 14C chronology and PSV and RPI chronologies wiggle-matched to field models suggests a hard-water effect of ~1000 yr, although we cannot rule out the possibility that at least some of the age offset represents a post-depositional remanent magnetization lock-in effect at Cascade Lake. S-ratios (IRM0.3T/SIRM) and ARM-ratios (ARM/SIRM) show a sharp decrease in low-coercivity material across the transition from clastic sediments to organic-rich sediments, followed by an increase in the concentration of fine-grained magnetic material and fining of the magnetic grain size up core, along with an increase in organic matter after ~10 ka

  16. Cosmology with Negative Absolute Temperatures

    CERN Document Server

    Vieira, J P P; Lewis, Antony

    2016-01-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al (2013) has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion ($w<-1$) with no Big Rip, and their contracting counterparts are forced to bounce after the energy density becomes sufficiently large. Both scenarios might be used to solve horizon and flatness problems analogously to standard inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  17. Cosmology with negative absolute temperatures

    Science.gov (United States)

    Vieira, J. P. P.; Byrnes, Christian T.; Lewis, Antony

    2016-08-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al. [1] has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion (w inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  18. Decadal to millennial scale archaeointensity variations in the Levant

    Science.gov (United States)

    Shaar, R.; Tauxe, L.; Ron, H.; Agnon, A.; Ben-Yosef, E.; Finkelstein, I.

    2013-12-01

    Recovering the absolute intensity of the past geomagnetic field (paleointensity) is a fundamental effort in the paleomagnetic research, but it is a complicated task. Paleointensity experiments should be carefully designed using sufficient number of specimens, and accurate correction for remanence anisotropy, cooling rate effects, and non-linear TRM (NLT). In addition, the basic assumption of the paleointensity method - a stable thermoremanent magnetization carried by single domain like particles - is hard to test using non-destructive methods. As a result, the interpretation of the paleointensity experiments can be non-unique and ambiguous. Moreover, the experimental difficulties compound with dating uncertainties related to the studied materials. We address each of these difficulties in an effort to construct a high resolution paleointensity curve of the Levant on archaeological time scales (archaeointensity). To address the experimental issues we apply the Thellier-type IZZI protocol with additional anisotropy, cooling rate, and NLT corrections. To ensure consistency, comparability, and objectivity of the interpretations we apply an automatic data analysis technique using an open code computer program (PmagPy Thellier GUI). To account for ambiguous interpretations we make the raw data, which include thousands of specimens, available in the MagIC database to allow other researchers to re-interpret and compile the datasets. Here we present the current status of the Levantine archaeointensity curve, and discuss its implication on our understanding of geomagnetic secular variations. The Levantine dataset includes mostly data from slag deposits - industrial heaps of metallurgic slag, and archaeological mounds ('Tel') - stratified sites created by cities rebuilt on top of others. The two types of records complement each other in a constructive fashion. The slag deposits provide records in a decadal resolution, while the mounds offer centennial to millennial scale

  19. Measurement of the absolute speed is possible?

    OpenAIRE

    Sergey V. Shevchenko; Tokarevsky, Vladimir V.

    2016-01-01

    One of popular problems, which  are experimentally studied in physics in a long time, is the testing of the special relativity theory, first of all – measurements of isotropy and constancy of light speed; as well as attempts to determine so called “absolute speed”, i.e. the Earth speed in the absolute spacetime (absolute reference frame), if this spacetime (ARF) exists.  Corresponding experiments aimed at the measuring of proper speed of some reference frame in oth...

  20. Inequalities, Absolute Value, and Logical Connectives.

    Science.gov (United States)

    Parish, Charles R.

    1992-01-01

    Presents an approach to the concept of absolute value that alleviates students' problems with the traditional definition and the use of logical connectives in solving related problems. Uses a model that maps numbers from a horizontal number line to a vertical ray originating from the origin. Provides examples solving absolute value equations and…

  1. Absolute Income, Relative Income, and Happiness

    Science.gov (United States)

    Ball, Richard; Chernova, Kateryna

    2008-01-01

    This paper uses data from the World Values Survey to investigate how an individual's self-reported happiness is related to (i) the level of her income in absolute terms, and (ii) the level of her income relative to other people in her country. The main findings are that (i) both absolute and relative income are positively and significantly…

  2. Investigating Absolute Value: A Real World Application

    Science.gov (United States)

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  3. Monolithically integrated absolute frequency comb laser system

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, Michael C.

    2016-07-12

    Rather than down-convert optical frequencies, a QCL laser system directly generates a THz frequency comb in a compact monolithically integrated chip that can be locked to an absolute frequency without the need of a frequency-comb synthesizer. The monolithic, absolute frequency comb can provide a THz frequency reference and tool for high-resolution broad band spectroscopy.

  4. Rock magnetic response to climatic changes in west Philippine Sea for the last 780 ka:Discussion based on relative paleointensity assisted chronology

    Institute of Scientific and Technical Information of China (English)

    Shulan GE; Xuefa SHI; Gang YANG; Yonghua WU

    2008-01-01

    We conducted rock magnetic and paleomagnetic research on two deep-sea sediment cores from the west Philippine Sea,located to the east of Benham Rise With the length of 4 m and water depth of over 5000 m.At the bottom of core 146 occurs a reversal of inclination and deflection of relative declination,which is recognized as BrunhesMatuyama Polarity Boundary(MBPB).No reversal occurs in core 89.which implies a younger bottom age than that of core 146.Rock magnetic results reveal-magnetic uniformities in mineralogy,concentration and grain size along the two cores,thus relative paleointensity variations are acquired.The three normalizers-anhysteresis remanent magnetization(ARM),magnetic susceptibility(K)and saturation isothermal remanent magnetization(SIRM)are used for normalization to obtain relative Daleointensities.The three normalization results are averaged to indicate the paleoitensity of the cores and are further stacked together to get a synthetic curve for west Philippine Sea(named as WPS800 in this paper).Based on the magnetic correlation between cores and paleointensity to Sint800,we transfer the changes of rock magnetic parameters from depth to time.Furthermore,the astronomically tuned oxygen isotope from ODP site 1143 in the south China Sea is used for the glacial and interglacial indicator.Three concentration proxies(ARM,K and SIRM)and grain size indicators(KARM/SIRM,KARM/K)are examined according to the paleointensity-assisted chronology.The grain size changes in the two cores display a consistent pattem with the climatic changes embodied bv oxygen isotope.The magnetic sizes are usually coarser in glacial periods and finer in interglacial times,which may reflect the influence of chemical erosion rather than fining from sea level rising on the source sediment.Furthermore,the sub-peaks and subtroughs in interglaciations almost correspond with that of oxygen isotope records,which means sedimentation can refect the subtle changes in interglaciations.This kind

  5. The Simplicity Argument and Absolute Morality

    Science.gov (United States)

    Mijuskovic, Ben

    1975-01-01

    In this paper the author has maintained that there is a similarity of thought to be found in the writings of Cudworth, Emerson, and Husserl in his investigation of an absolute system of morality. (Author/RK)

  6. Absolute calibration technique for spontaneous fission sources

    International Nuclear Information System (INIS)

    An absolute calibration technique for a spontaneously fissioning nuclide (which involves no arbitrary parameters) allows unique determination of the detector efficiency for that nuclide, hence of the fission source strength

  7. Absolute distance metrology for space interferometers

    OpenAIRE

    Swinkels, B L; Wendrich, T.J.; Bhattacharya, N; Wielders, A.A.; Braat, J.J.M.

    2004-01-01

    Space interferometers consisting of several free flying telescopes, such as the planned Darwin mission, require a complex metrology system to make all the components operate as a single instrument. Our research focuses on one of its sub-systems that measures the absolute distance between two satellites with high accuracy. For Darwin the required accuracy would be in the order of 10 μm over 250 meter. To measure this absolute distance, we are currently exploring the frequency sweeping interfer...

  8. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  9. A 300 kyr Record of Geomagnetic Excursions and Paleointensity From the Irminger Basin: Candidates for Mono Lake, Laschamp, Iceland Basin, Jamaica and Pringle Falls?

    Science.gov (United States)

    Channell, J. E.

    2004-12-01

    Sediments recovered at ODP Site 919, off east Greenland, record geomagnetic directional excursions at 33 ka and 40 ka (Mono Lake and Laschamp), and at 187 ka (Iceland Basin), 208 ka (Jamaica?) and at 220 ka (Pringle Falls). U-channel records are augmented by 1-cm discrete samples collected back-to-back alongside the u-channel troughs. Deconvolution of the u-channel records yields records that can be closely matched to the discrete sample data. The age-model based on planktic oxygen isotope data (St. John et al., Marine Geology, in press) is consistent with the relative paleointensity record and the recognition of Ash Layer 2 (55 ka). The results indicate that the Mono Lake and Laschamp excursions, and the Iceland Basin and Pringle Falls (and perhaps also Jamaica), are distinct excursions, rarely recorded together in individual stratigraphic sections. Why are they recorded at ODP Site 919? Mean sedimentation rates are 22 cm/kyr in MIS 3 where Mono Lake/Laschamp are recorded, but sedimentation rates do not appear to be especially high in MIS 7 (13 cm/kyr) where candidates for Iceland Basin/Jamaica/Pringle Falls are recorded.

  10. Universal Cosmic Absolute and Modern Science

    Science.gov (United States)

    Kostro, Ludwik

    The official Sciences, especially all natural sciences, respect in their researches the principle of methodic naturalism i.e. they consider all phenomena as entirely natural and therefore in their scientific explanations they do never adduce or cite supernatural entities and forces. The purpose of this paper is to show that Modern Science has its own self-existent, self-acting, and self-sufficient Natural All-in Being or Omni-Being i.e. the entire Nature as a Whole that justifies the scientific methodic naturalism. Since this Natural All-in Being is one and only It should be considered as the own scientifically justified Natural Absolute of Science and should be called, in my opinion, the Universal Cosmic Absolute of Modern Science. It will be also shown that the Universal Cosmic Absolute is ontologically enormously stratified and is in its ultimate i.e. in its most fundamental stratum trans-reistic and trans-personal. It means that in its basic stratum. It is neither a Thing or a Person although It contains in Itself all things and persons with all other sentient and conscious individuals as well, On the turn of the 20th century the Science has begun to look for a theory of everything, for a final theory, for a master theory. In my opinion the natural Universal Cosmic Absolute will constitute in such a theory the radical all penetrating Ultimate Basic Reality and will substitute step by step the traditional supernatural personal Absolute.

  11. Absolute Magnetization Distribution on Back-arc Spreading Axis Hosting Hydrothermal Vents; Insight from Shinkai 6500 Magnetic Survey

    Science.gov (United States)

    Fujii, M.; Okino, K.; Honsho, C.; Mochizuki, N.; Szitkar, F.; Dyment, J.

    2013-12-01

    Near-bottom magnetic profiling using submersible, deep-tow, Remotely Operated Vehicle (ROV) and Autonomous Underwater Vehicle (AUV) make possible to conduct high-resolution surveys and depict detailed magnetic features reflecting, for instance, the presence of fresh lavas or hydrothermal alteration, or geomagnetic paleo-intensity variations. We conducted near-bottom three component magnetic measurements onboard submersible Shinkai 6500 in the Southern Mariana Trough, where five active hydrothermal vent fields (Snail, Yamanaka, Archean, Pica, and Urashima sites) have been found in both on- and off-axis areas of the active back-arc spreading center, to detect signals from hydrothermally altered rock and to distinguish old and new submarine lava flows. Fourteen dives were carried out at an altitude of 1-40 m during the R/V Yokosuka YK10-10 and YK10-11 cruises in 2010. We carefully corrected the effect of the induced and permanent magnetizations of the submersible by applying the correction method for the shipboard three-component magnetometer measurement modified for deep-sea measurement, and subtracted the IGRF values from the corrected data to obtain geomagnetic vector anomalies along the dive tracks. We then calculated the synthetic magnetic vector field produced by seafloor, assumed to be uniformly magnetized, using three dimensional forward modeling. Finally, values of the absolute magnetizations were estimated by using a linear transfer function in the Fourier domain from the observed and synthetic magnetic anomalies. The distribution of estimated absolute magnetization generally shows low values around the five hydrothermal vent sites. This result is consistent with the equivalent magnetization distribution obtained from previous AUV survey data. The areas of low magnetization are also consistent with hydrothermal deposits identified in video records. These results suggest that low magnetic signals are due to hydrothermal alteration zones where host rocks are

  12. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  13. Quantum theory allows for absolute maximal contextuality

    Science.gov (United States)

    Amaral, Barbara; Cunha, Marcelo Terra; Cabello, Adán

    2015-12-01

    Contextuality is a fundamental feature of quantum theory and a necessary resource for quantum computation and communication. It is therefore important to investigate how large contextuality can be in quantum theory. Linear contextuality witnesses can be expressed as a sum S of n probabilities, and the independence number α and the Tsirelson-like number ϑ of the corresponding exclusivity graph are, respectively, the maximum of S for noncontextual theories and for the theory under consideration. A theory allows for absolute maximal contextuality if it has scenarios in which ϑ /α approaches n . Here we show that quantum theory allows for absolute maximal contextuality despite what is suggested by the examination of the quantum violations of Bell and noncontextuality inequalities considered in the past. Our proof is not constructive and does not single out explicit scenarios. Nevertheless, we identify scenarios in which quantum theory allows for almost-absolute-maximal contextuality.

  14. Absolute photoacoustic thermometry in deep tissue.

    Science.gov (United States)

    Yao, Junjie; Ke, Haixin; Tai, Stephen; Zhou, Yong; Wang, Lihong V

    2013-12-15

    Photoacoustic thermography is a promising tool for temperature measurement in deep tissue. Here we propose an absolute temperature measurement method based on the dual temperature dependences of the Grüneisen parameter and the speed of sound in tissue. By taking ratiometric measurements at two adjacent temperatures, we can eliminate the factors that are temperature irrelevant but difficult to correct for in deep tissue. To validate our method, absolute temperatures of blood-filled tubes embedded ~9 mm deep in chicken tissue were measured in a biologically relevant range from 28°C to 46°C. The temperature measurement accuracy was ~0.6°C. The results suggest that our method can be potentially used for absolute temperature monitoring in deep tissue during thermotherapy.

  15. Absolute Stability And Hyperstability In Hilbert Space

    Science.gov (United States)

    Wen, John Ting-Yung

    1989-01-01

    Theorems on stabilities of feedback control systems proved. Paper presents recent developments regarding theorems of absolute stability and hyperstability of feedforward-and-feedback control system. Theorems applied in analysis of nonlinear, adaptive, and robust control. Extended to provide sufficient conditions for stability in system including nonlinear feedback subsystem and linear time-invariant (LTI) feedforward subsystem, state space of which is Hilbert space, and input and output spaces having finite numbers of dimensions. (In case of absolute stability, feedback subsystem memoryless and possibly time varying. For hyperstability, feedback system dynamical system.)

  16. Absolute-Magnitude Distributions of Supernovae

    CERN Document Server

    Richardson, Dean; Wright, John; Maddox, Larry

    2014-01-01

    The absolute-magnitude distributions of seven supernova types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M_B -15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of -19.25. The IIP distribution was the dimmest at -16.75.

  17. Precise Measurement of the Absolute Fluorescence Yield

    Science.gov (United States)

    Ave, M.; Bohacova, M.; Daumiller, K.; Di Carlo, P.; di Giulio, C.; San Luis, P. Facal; Gonzales, D.; Hojvat, C.; Hörandel, J. R.; Hrabovsky, M.; Iarlori, M.; Keilhauer, B.; Klages, H.; Kleifges, M.; Kuehn, F.; Monasor, M.; Nozka, L.; Palatka, M.; Petrera, S.; Privitera, P.; Ridky, J.; Rizi, V.; D'Orfeuil, B. Rouille; Salamida, F.; Schovanek, P.; Smida, R.; Spinka, H.; Ulrich, A.; Verzi, V.; Williams, C.

    2011-09-01

    We present preliminary results of the absolute yield of fluorescence emission in atmospheric gases. Measurements were performed at the Fermilab Test Beam Facility with a variety of beam particles and gases. Absolute calibration of the fluorescence yield to 5% level was achieved by comparison with two known light sources--the Cherenkov light emitted by the beam particles, and a calibrated nitrogen laser. The uncertainty of the energy scale of current Ultra-High Energy Cosmic Rays experiments will be significantly improved by the AIRFLY measurement.

  18. Det demokratiske argument for absolut ytringsfrihed

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2014-01-01

    Artiklen diskuterer den påstand, at absolut ytringsfrihed er en nødvendig forudsætning for demokratisk legitimitet med udgangspunkt i en rekonstruktion af et argument fremsat af Ronald Dworkin. Spørgsmålet er, hvorfor ytringsfrihed skulle være en forudsætning for demokratisk legitimitet, og hvorf...

  19. Time Function and Absolute Black Hole

    DEFF Research Database (Denmark)

    Javadi, Hossein; Forouzbakhsh, Farshid

    2006-01-01

    Einstein’s theory of gravity is not consistent with quantum mechanics, because general relativity cannot be quantized. [1] But without conversion of force and energy, it is impossible to find a grand unified theory. A very important result of CPH theory is time function that allows we give a new ...... description of absolute black hole and before the big bang....

  20. Teaching Absolute Value Inequalities to Mature Students

    Science.gov (United States)

    Sierpinska, Anna; Bobos, Georgeana; Pruncut, Andreea

    2011-01-01

    This paper gives an account of a teaching experiment on absolute value inequalities, whose aim was to identify characteristics of an approach that would realize the potential of the topic to develop theoretical thinking in students enrolled in prerequisite mathematics courses at a large, urban North American university. The potential is…

  1. ABSOLUTE MEASUREMENT OF THE GANIL BEAM ENERGY

    NARCIS (Netherlands)

    CASANDJIAN, JM; MITTIG, W; BEUNARD, R; GAUDARD, L; LEPINESZILY, A; VILLARI, ACC; AUGER, G; BIANCHI, L; CUNSOLO, A; FOTI, A; LICHTENTHALER, R; PLAGNOL, E; SCHUTZ, Y; SIEMSSEN, RH; WIELECZKO, JP

    1993-01-01

    The energy of the GANIL cyclotron beam was measured on-line during the Pb-208 + Pb-208 elastic scattering experiment ''Search for Color van der Waals Force in the Pb-208 + Pb-208 Mott scattering'' with an absolute precision of 7 x 10(-5) at approximately 1.0 GeV, which represents an improvement of o

  2. Stimulus Probability Effects in Absolute Identification

    Science.gov (United States)

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  3. Solving Absolute Value Equations Algebraically and Geometrically

    Science.gov (United States)

    Shiyuan, Wei

    2005-01-01

    The way in which students can improve their comprehension by understanding the geometrical meaning of algebraic equations or solving algebraic equation geometrically is described. Students can experiment with the conditions of the absolute value equation presented, for an interesting way to form an overall understanding of the concept.

  4. Absolute-stability results in infinite dimensions

    NARCIS (Netherlands)

    Curtain, RF; Logemann, H; Staffans, O

    2004-01-01

    We derive absolute-stability results of Popov and circle-criterion type for infinite-dimensional systems in an input-output setting. Our results apply to feedback systems in which the linear part is the series interconnection of an input-output stable linear system and an integrator, and the nonline

  5. Magnetoresistive sensor for absolute position detection

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1984-01-01

    A digital measurement principle for absolute position is decscribed. The position data is recorded serially into a single track of a hard-magnetic layer with the help of longitudinal saturation recording. Detection is possible by means of an array of sensor elements which can be made of a substrate.

  6. Thin-film magnetoresistive absolute position detector

    NARCIS (Netherlands)

    Groenland, Johannes Petrus Jacobus

    1990-01-01

    The subject of this thesis is the investigation of a digital absolute posi- tion-detection system, which is based on a position-information carrier (i.e. a magnetic tape) with one single code track on the one hand, and an array of magnetoresistive sensors for the detection of the informatio

  7. Magnetoresistive transducer for absolute position detection

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1984-01-01

    In this paper a new method is presented for the measurement of absolute linear or angular position. The digital position information is recorded serially into one track of a suitable hard-magnetic medium. The stray field of this information layer determines the angular magnetisation distribution in

  8. A stacked record of relative geomagnetic paleointensity for the past 270 kyr from the western continental rise of the Antarctic Peninsula

    Science.gov (United States)

    Macrì, Patrizia; Sagnotti, Leonardo; Lucchi, Renata Giulia; Rebesco, Michele

    2006-11-01

    Paleomagnetic and rock magnetic investigations were carried out on four gravity cores recovered from the western continental rise of the Antarctic Peninsula during the SEDANO II cruise of RV OGS-Explora. The studied cores, each about 6.5 m-long, were collected at a depth of 3700-4100 m below the sea level, on the distal gentle side of sediment Drift 7, and consist of very fine-grained sediments spanning through various glacial-interglacial cycles. Detailed analysis of the paleomagnetic and rock magnetic data allowed to reconstruct relative paleointensity (RPI) records (NRM20 mT/ARM20 mT) for each core. We established a refined age model for the studied sequences by correlating individual SEDANO RPI curves to the global RPI stack SINT-800 [Y. Guyodo, J.-P. Valet, Global changes in intensity of the Earth's magnetic field during the past 800 kyr, Nature 399 (1999) 249-252]. The individual normalized SEDANO RPI records are in mutual close agreement; they were thus merged in a RPI stacking curve spanning the last 270 kyr and showing a low standard deviation. This study also points out that RPI records may provide a viable tool to date otherwise difficult-to-date sedimentary sequences, such as those deposited along peri-Antarctic margins. The new RPI chronology indicates that the sampled sedimentary sequence is younger than previously thought and allows a new high-resolution correlation to oxygen isotope stages. Furthermore, we recognized variations in the rock magnetic parameters that appear to be climatically-driven, with changes in the relative proportion of two magnetic mineral populations with distinct coercivities. Rock magnetic and lithological trends observed in the SEDANO cores indicate that during the climatic cycles of the Late Pleistocene this sector of the peri-Antarctic margin was subjected to subtle, yet identifiable, environmental changes, confirming a relatively higher instability of the West Antarctic ice sheet with respect to the East Antarctic

  9. Paleomagnetic and rock magnetic study of IODP Site U1408 in the Northwest Atlantic - toward the high-resolution relative paleointensity estimate during the middle Eocene

    Science.gov (United States)

    Yamamoto, Y.; Yamazaki, T.; Oda, H.

    2015-12-01

    We have conducted paleomagnetic and rock magnetic measurements on the sedimentary sections recovered from Integrated Ocean Drilling Program (IODP) Site U1408 in the Northwest Atlantic, off Newfoundland. The measurements were done on u-channel samples using a pass-through superconducting rock magnetometer in a manner that remanent magnetizations (natural, anhysteretic and isothermal remanent magnetizations: NRM, ARM and IRM) were subjected to stepwise alternating field (AF) demagnetizations up to 80 mT and are measured with 1 cm spacing at each step.The characteristic remanent magnetization (ChRM) was resolved after AF demagnetization of 20-30 mT for most of the studied interval. As a result, we could identify several polarity reversals which were able to be correlated with the geomagnetic polarity time scale by Gradstein et al. (2012) (Geologic Time Scale 2012), with referring the shipboard biostratigraphy (Norris et al., 2014). The interval at ~ 33-157 mcd (meter composite depth) was interpreted to cover the Chrons C18n.1n to C20n with missing Chron C19n because of the somewhat ambiguous magnetic signals at the interval at ~ 70-110 mcd. The correlation provided an age model inferring sedimentation rate of about 2-4 cm/kyr during these chrons.There is the interval that shows relatively constant ARM and IRM intensities as well as ratios of ARM to IRM (ARM/IRM): the interval at ~ 37-90 mcd resulted in ARM intensity of 0.2-0.4 A/m, IRM intensity of 1-2 A/m and ARM/IRM of 0.17-0.20. This interval corresponds to the Chron C18 and the estimated sedimentation rate of the interval is ~ 2 cm/kyr. It is expected that high-resolution relative paleointensity estimate during the middle Eocene is potentially possible. We will report a preliminary estimate.

  10. An absolute measure for a key currency

    Science.gov (United States)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  11. Absolute Parallelism Geometry: Developments, Applications and Problems

    OpenAIRE

    Wanas, M. I.

    2002-01-01

    Absolute parallelism geometry is frequently used for physical applications. It has two main defects, from the point of view of applications. The first is the identical vanishing of its curvature tensor. The second is that its autoparallel paths do not represent physical trajectories. The present work shows how these defects were treated in the course of development of the geometry. The new version of this geometry contains simultaneous non-vanishing torsion and curvatures. Also, the new paths...

  12. Cosmological frames for theories with absolute parallelism

    OpenAIRE

    Ferraro, Rafael; Fiorini, Franco

    2011-01-01

    The vierbein (tetrad) fields for closed and open Friedmann-Robertson-Walker cosmologies are hard to work out in most of the theories featuring absolute parallelism. The difficulty is traced in the fact that these theories are not invariant under local Lorentz transformations of the vierbein. We illustrate this issue in the framework of f(T) theories and Born-Infeld determinantal gravity. In particular, we show that the early Universe as described by the Born-Infeld scheme is singularity free ...

  13. The absolute differential calculus (calculus of tensors)

    CERN Document Server

    Levi-Civita, Tullio

    2013-01-01

    Written by a towering figure of twentieth-century mathematics, this classic examines the mathematical background necessary for a grasp of relativity theory. Tullio Levi-Civita provides a thorough treatment of the introductory theories that form the basis for discussions of fundamental quadratic forms and absolute differential calculus, and he further explores physical applications.Part one opens with considerations of functional determinants and matrices, advancing to systems of total differential equations, linear partial differential equations, algebraic foundations, and a geometrical intro

  14. Absolute clock synchronisation and special relativity paradoxes

    OpenAIRE

    Ciborowski, Jacek; Wlodarczyk, Marta

    2012-01-01

    Solving special relativity paradoxes requires rigorous analysis of event timing, due to relative simultaneity in consequence of the Lorentz transformation. Since clock synchronisation is a convention in special theory of relativity, instead of the Einstein's procedure one may choose such that offers absolute simultaneity. We present in short the corresponding formalism in one spatial dimension. We show that paradoxes do not arise with this choice of synchronisation and descriptions of these i...

  15. Absolute distance metrology for space interferometers

    OpenAIRE

    Swinkels, B L; Bhattacharya, N; Wielders, A.A.; Braat, J.J.M.

    2005-01-01

    Future space missions, among which the Darwin Space Interferometer, will consist of several free flying satellites. A complex metrology system is required to have all the components fly accurately in formation and have it operate as a single instrument. Our work focuses on a possible implementation of the sub-system that measures the absolute distance between two satellites with high accuracy. For Darwin the required accuracy is on the order of 70 micrometer over a distance of 250 meter. We a...

  16. Measurement of absolute gravity acceleration in Firenze

    Directory of Open Access Journals (Sweden)

    M. de Angelis

    2011-01-01

    Full Text Available This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the University of Firenze (Italy. In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the Newtonian law at short distances are in progress. Both experiments require an independent knowledge on the local value of g. The only available datum, pertaining to the italian zero-order gravity network, was taken more than 20 years ago at a distance of more than 60 km from the study site. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are (980 492 160.6 ± 4.0 μGal and (980 492 048.3 ± 3.0 μGal for the European Laboratory for Non-Linear Spectroscopy (LENS and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  17. Measurement of absolute gravity acceleration in Firenze

    Science.gov (United States)

    de Angelis, M.; Greco, F.; Pistorio, A.; Poli, N.; Prevedelli, M.; Saccorotti, G.; Sorrentino, F.; Tino, G. M.

    2011-01-01

    This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the University of Firenze (Italy). In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the Newtonian law at short distances are in progress. Both experiments require an independent knowledge on the local value of g. The only available datum, pertaining to the italian zero-order gravity network, was taken more than 20 years ago at a distance of more than 60 km from the study site. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are (980 492 160.6 ± 4.0) μGal and (980 492 048.3 ± 3.0) μGal for the European Laboratory for Non-Linear Spectroscopy (LENS) and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  18. Absolute calibration of the Auger fluorescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bauleo, P.; Brack, J.; Garrard, L.; Harton, J.; Knapik, R.; Meyhandan, R.; Rovero, A.C.; /Buenos Aires, IAFE; Tamashiro, A.; Warner, D.

    2005-07-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acquisition system give the required calibration for each pixel. In the lab, light source uniformity is studied using CCD images and the intensity is measured relative to NIST-calibrated photodiodes. Overall uncertainties are presently 12%, and are dominated by systematics.

  19. Musical Activity Tunes Up Absolute Pitch Ability

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Ribe, Lars Riisgaard;

    2014-01-01

    Absolute pitch (AP) is the ability to identify or produce pitches of musical tones without an external reference. Active AP (i.e., pitch production or pitch adjustment) and passive AP (i.e., pitch identification) are considered to not necessarily coincide, although no study has properly compared...... that APs generally undershoot when adjusting musical pitch, a tendency that decreases when musical activity increases. Finally, APs are less accurate when adjusting the pitch to black key targets than to white key targets. Hence, AP ability may be partly practice-dependent and we speculate that APs may...... benefit from frequent contact with fixed standard chroma to keep in tune....

  20. Absolute Priority for a Vehicle in VANET

    Science.gov (United States)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  1. Development of an absolute neutron dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Acevedo, C; Birstein, L; Loyola, H [Section de Desarrollos Innovativos, Comision Chilena de EnergIa Nuclear (CCHEN), Casilla 188-D, Santiago (Chile)], E-mail: lbirstei@cchen.cl

    2008-11-01

    An Absolute Neutron Dosimeter was developed to be used as a calibration standard for the Radiation Metrology Laboratory at CCHEN. The main component of the Dosimeter consists of a Proportional Counter of cylindrical shape, with Polyethylene walls and Ethylene gas in its interior. It includes a cage shaped arrangement of graphite bars that operates like the Proportional Counter cathode and a tungsten wire of 25 {mu}m in diameter {mu}m as the anode. Results of a Montecarlo modeling for the Dosimeter operation and results of tests and measurements performed with a radioactive source are presented.

  2. ABSOLUT LOMO绝对创意

    Institute of Scientific and Technical Information of China (English)

    婷婷(整理)

    2007-01-01

    ABSOLUT与创意素来有着不解之缘。由Andy Warhal的ABSOLUT WARHOL至今,已有超过400位不同领域的创意大师为ABSOLUT的当代艺术宝库贡献了自己的得意之作。ABSOLUT的创意仿佛永远不会枯竭,而一系列的作品也让惊喜从未落空。

  3. Variance computations for functional of absolute risk estimates

    OpenAIRE

    Pfeiffer, R. M.; E. Petracci

    2011-01-01

    We present a simple influence function based approach to compute the variances of estimates of absolute risk and functions of absolute risk. We apply this approach to criteria that assess the impact of changes in the risk factor distribution on absolute risk for an individual and at the population level. As an illustration we use an absolute risk prediction model for breast cancer that includes modifiable risk factors in addition to standard breast cancer risk factors. Influence function base...

  4. Isotope dilution strategies for absolute quantitative proteomics

    International Nuclear Information System (INIS)

    The development of mass spectrometry (MS)-based methodologies for high-throughput protein identification has generated a concomitant need for protein quantification. Numerous MS-based relative quantification methodologies have been dedicated to the extensive comparison of multiple proteomes. On the other hand, absolute quantification methodologies, which allow the determination of protein concentrations in biological samples, are generally restricted to defined sets of proteins. Depending on the selected analytical procedure, absolute quantification approaches can provide accurate and precise estimations. These analytical performances are crucial for specific applications such as the evaluation of clinical bio-marker candidates. According to bioanalytical guidelines, accurate analytical processes require internal standards and quality controls. Regarding MS-based analysis of small molecules, isotope dilution has been recognized as the reference method for internal standardization. However, protein quantification methodologies which rely on the isotope dilution principle have been implemented in the proteomic field only recently. In these approaches, the sample is spiked with defined amounts of isotope-labeled analogue(s) of specific proteolytic peptide(s) (AQUA and QconCAT strategies) or protein(s) (PSAQ strategy). In this review, we present a critical overview of these isotope dilution methodologies. (authors)

  5. A Conceptual Approach to Absolute Value Equations and Inequalities

    Science.gov (United States)

    Ellis, Mark W.; Bryson, Janet L.

    2011-01-01

    The absolute value learning objective in high school mathematics requires students to solve far more complex absolute value equations and inequalities. When absolute value problems become more complex, students often do not have sufficient conceptual understanding to make any sense of what is happening mathematically. The authors suggest that the…

  6. Using, Seeing, Feeling, and Doing Absolute Value for Deeper Understanding

    Science.gov (United States)

    Ponce, Gregorio A.

    2008-01-01

    Using sticky notes and number lines, a hands-on activity is shared that anchors initial student thinking about absolute value. The initial point of reference should help students successfully evaluate numeric problems involving absolute value. They should also be able to solve absolute value equations and inequalities that are typically found in…

  7. Invariant and Absolute Invariant Means of Double Sequences

    Directory of Open Access Journals (Sweden)

    Abdullah Alotaibi

    2012-01-01

    Full Text Available We examine some properties of the invariant mean, define the concepts of strong σ-convergence and absolute σ-convergence for double sequences, and determine the associated sublinear functionals. We also define the absolute invariant mean through which the space of absolutely σ-convergent double sequences is characterized.

  8. Use of Absolute and Comparative Performance Feedback in Absolute and Comparative Judgments and Decisions

    Science.gov (United States)

    Moore, Don A.; Klein, William M. P.

    2008-01-01

    Which matters more--beliefs about absolute ability or ability relative to others? This study set out to compare the effects of such beliefs on satisfaction with performance, self-evaluations, and bets on future performance. In Experiment 1, undergraduate participants were told they had answered 20% correct, 80% correct, or were not given their…

  9. Variance computations for functional of absolute risk estimates.

    Science.gov (United States)

    Pfeiffer, R M; Petracci, E

    2011-07-01

    We present a simple influence function based approach to compute the variances of estimates of absolute risk and functions of absolute risk. We apply this approach to criteria that assess the impact of changes in the risk factor distribution on absolute risk for an individual and at the population level. As an illustration we use an absolute risk prediction model for breast cancer that includes modifiable risk factors in addition to standard breast cancer risk factors. Influence function based variance estimates for absolute risk and the criteria are compared to bootstrap variance estimates.

  10. Absolute geostrophic currents in global tropical oceans

    Science.gov (United States)

    Yang, Lina; Yuan, Dongliang

    2016-11-01

    A set of absolute geostrophic current (AGC) data for the period January 2004 to December 2012 are calculated using the P-vector method based on monthly gridded Argo profiles in the world tropical oceans. The AGCs agree well with altimeter geostrophic currents, Ocean Surface Current Analysis-Real time currents, and moored current-meter measurements at 10-m depth, based on which the classical Sverdrup circulation theory is evaluated. Calculations have shown that errors of wind stress calculation, AGC transport, and depth ranges of vertical integration cannot explain non-Sverdrup transport, which is mainly in the subtropical western ocean basins and equatorial currents near the Equator in each ocean basin (except the North Indian Ocean, where the circulation is dominated by monsoons). The identified non-Sverdrup transport is thereby robust and attributed to the joint effect of baroclinicity and relief of the bottom (JEBAR) and mesoscale eddy nonlinearity.

  11. Absolute measurements of fast neutrons using yttrium

    International Nuclear Information System (INIS)

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be fn∼4.1x10-4 with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 108 neutrons per discharge.

  12. MAGSAT: Vector magnetometer absolute sensor alignment determination

    Science.gov (United States)

    Acuna, M. H.

    1981-01-01

    A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

  13. Absolute astrometry in the next 50 years

    CERN Document Server

    Høg, Erik

    2014-01-01

    With ESA's astrometry satellite Gaia in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A dozen science issues for a Gaia successor mission in twenty years are presented and in this context the possibilities for absolute astrometry with mas or sub-mas accuracies are discussed. The three powerful techniques: VLBI, the MICADO camera on the E-ELT, and the LSST are described and documented by literature references and by an extensive correspondence with leading astronomers who readily responded with all the information I needed. In brief, the two Gaia-like missions would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems to compact galaxies, quasars and dark matter by data which cannot be surpassed in the next 50 years.

  14. How is an absolute democracy possible?

    Directory of Open Access Journals (Sweden)

    Joanna Bednarek

    2011-01-01

    Full Text Available In the last part of the Empire trilogy, Commonwealth, Negri and Hardt ask about the possibility of the self-governance of the multitude. When answering, they argue that absolute democracy, understood as the political articulation of the multitude that does not entail its unification (construction of the people is possible. As Negri states, this way of thinking about political articulation is rooted in the tradition of democratic materialism and constitutes the alternative to the dominant current of modern political philosophy that identifies political power with sovereignty. The multitude organizes itself politically by means of the constitutive power, identical with the ontological creativity or productivity of the multitude. To state the problem of political organization means to state the problem of class composition: political democracy is at the same time economic democracy.

  15. Absolute radiometric calibration of the CCRS SAR

    Science.gov (United States)

    Ulander, Lars M. H.; Hawkins, Robert K.; Livingstone, Charles E.; Lukowski, Tom I.

    1991-11-01

    Determining the radar scattering coefficients from SAR (synthetic aperture radar) image data requires absolute radiometric calibration of the SAR system. The authors describe an internal calibration methodology for the airborne Canada Centre for Remote Sensing (CCRS) SAR system, based on radar theory, a detailed model of the radar system, and measurements of system parameters. The methodology is verified by analyzing external calibration data acquired over a 6-month period in 1988 by the C-band radar using HH polarization. The results indicate that the overall error is +/- 0.8 dB (1-sigma) for incidence angles +/- 20 deg from antenna boresight. The dominant error contributions are due to the antenna radome and uncertainties in the elevation angle relative to the antenna boresight.

  16. WHY DOES LEIBNIZ NEED ABSOLUTE TIME?

    Directory of Open Access Journals (Sweden)

    NICOLÁS VAUGHAN C.

    2007-08-01

    Full Text Available Resumen: En este ensayo pongo en contraposición dos doctrinas conspicuamenteleibnicianas: la doctrina del tiempo relacional e ideal, y la doctrina de la armonía preestablecida. Argumentaré que si todas las substancias están necesariamentecoordinadas, entonces no tiene sentido negar el carácter absoluto y real del tiempo. En la primera sección describiré la concepción newtoniana y clarkeana del tiempo absoluto; en la segunda discutiré la crítica leibniciana a dicha concepción, crítica sobre la que se erige su doctrina relacional e ideal del tiempo; en la tercera sección daré un vistazo a la metafísica monádica madura de Leibniz, haciendo especial énfasis en la doctrina de la armonía preestablecida; finalmente, en la última sección sugeriré la existencia de una tensión irreconciliable entre estas dos doctrinas.Abstract: In this paper I bring together two characteristically Leibnizean doctrines:the doctrine of relational and ideal time, and the doctrine of preestablished harmony. I will argue that, if every substance is necessarily connected with another, then it makes no sense to deny absolute and real time. In the first section, I will describe Newton’s and Clarke’s conception of absolute time; then, in the second section, I will consider Leibniz’s critique of that conception, on which he bases his ideal and relational doctrine of time. In the third section I will look briefly at Leibniz’s mature monadic metaphysics, taking special account of his doctrine of preestablished harmony. In the last section, I will suggest that there is an irreconcilable tension between these two doctrines.

  17. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Jian-Zhou Zhu and Gregory W. Hammett

    2011-01-10

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, "On some statistical properties of hydrodynamical and magnetohydrodynamical fields," Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  18. Absolute value preconditioning for symmetric indefinite linear systems

    OpenAIRE

    Vecharynski, Eugene; Knyazev, Andrew V.

    2011-01-01

    We introduce a novel strategy for constructing symmetric positive definite (SPD) preconditioners for linear systems with symmetric indefinite matrices. The strategy, called absolute value preconditioning, is motivated by the observation that the preconditioned minimal residual method with the inverse of the absolute value of the matrix as a preconditioner converges to the exact solution of the system in at most two steps. Neither the exact absolute value of the matrix nor its exact inverse ar...

  19. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  20. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  1. The absolute disparity anomaly and the mechanism of relative disparities.

    Science.gov (United States)

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-06-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1).

  2. Evaluation of the absolute regional temperature potential

    Directory of Open Access Journals (Sweden)

    D. T. Shindell

    2012-09-01

    Full Text Available The Absolute Regional Temperature Potential (ARTP is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90–28° S, 28° S–28° N, 28–60° N and 60–90° N as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within ±20% of the actual responses, though there are some exceptions for 90–28° S and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the ±20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39–45% and 9–39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  3. Absolute Radiometric Calibration of KOMPSAT-3A

    Science.gov (United States)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  4. Absolute Humidity and the Seasonality of Influenza (Invited)

    Science.gov (United States)

    Shaman, J. L.; Pitzer, V.; Viboud, C.; Grenfell, B.; Goldstein, E.; Lipsitch, M.

    2010-12-01

    Much of the observed wintertime increase of mortality in temperate regions is attributed to seasonal influenza. A recent re-analysis of laboratory experiments indicates that absolute humidity strongly modulates the airborne survival and transmission of the influenza virus. Here we show that the onset of increased wintertime influenza-related mortality in the United States is associated with anomalously low absolute humidity levels during the prior weeks. We then use an epidemiological model, in which observed absolute humidity conditions temper influenza transmission rates, to successfully simulate the seasonal cycle of observed influenza-related mortality. The model results indicate that direct modulation of influenza transmissibility by absolute humidity alone is sufficient to produce this observed seasonality. These findings provide epidemiological support for the hypothesis that absolute humidity drives seasonal variations of influenza transmission in temperate regions. In addition, we show that variations of the basic and effective reproductive numbers for influenza, caused by seasonal changes in absolute humidity, are consistent with the general timing of pandemic influenza outbreaks observed for 2009 A/H1N1 in temperate regions. Indeed, absolute humidity conditions correctly identify the region of the United States vulnerable to a third, wintertime wave of pandemic influenza. These findings suggest that the timing of pandemic influenza outbreaks is controlled by a combination of absolute humidity conditions, levels of susceptibility and changes in population mixing and contact rates.

  5. Supplementary and Enrichment Series: Absolute Value. Teachers' Commentary. SP-25.

    Science.gov (United States)

    Bridgess, M. Philbrick, Ed.

    This is one in a series of manuals for teachers using SMSG high school supplementary materials. The pamphlet includes commentaries on the sections of the student's booklet, answers to the exercises, and sample test questions. Topics covered include addition and multiplication in terms of absolute value, graphs of absolute value in the Cartesian…

  6. Supplementary and Enrichment Series: Absolute Value. SP-24.

    Science.gov (United States)

    Bridgess, M. Philbrick, Ed.

    This is one in a series of SMSG supplementary and enrichment pamphlets for high school students. This series is designed to make material for the study of topics of special interest to students readily accessible in classroom quantity. Topics covered include absolute value, addition and multiplication in terms of absolute value, graphs of absolute…

  7. ABSOLUTE STABILITY OF GENERAL LURIE DISCRETE NONLINEAR CONTROL SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    GAN Zuoxin; HAN Jingqing; ZHAO Suxia; WU Yongxian

    2002-01-01

    In the present paper, the absolute stability of general Lurie discrete nonlinear control systems has been discussed by Lyapunov function approach. A sufficient condition of absolute stability for the general Lurie discrete nonlinear control systems is derived, and some necessary and sufficient conditions are obtained in special cases. Meanwhile, we give a simple example to illustrate the effectiveness of the results.

  8. Novalis' Poetic Uncertainty: A "Bildung" with the Absolute

    Science.gov (United States)

    Mika, Carl

    2016-01-01

    Novalis, the Early German Romantic poet and philosopher, had at the core of his work a mysterious depiction of the "absolute." The absolute is Novalis' name for a substance that defies precise knowledge yet calls for a tentative and sensitive speculation. How one asserts a truth, represents an object, and sets about encountering things…

  9. Absolute neutronic performance of SNS from gold foil application

    International Nuclear Information System (INIS)

    The determination of absolute neutron fluxes by white beam activation of thick gold foils in conjuction with spectral analysis by time-of-flight monitors is described. A numerical integration procedure is presented and the method applied to determining the absolute performance of SNS from data obtained during the initial commissioning run in December 1984. (author)

  10. Decadal to millennial scale geomagnetic field variations in the Levantine archaeointensity curve (LAC): methodology and applications

    Science.gov (United States)

    Shaar, Ron; Tauxe, Lisa; Ron, Hagai; Agnon, Amotz; Ben-Yosef, Erez; Finkelstein, Israel; Zuckerman, Sharon; Levy, Thomas E.

    2014-05-01

    Recovering the absolute intensity of the geomagnetic field on historical and archaeological timescale (archaeointensity) in a sufficient resolution is a fundamental effort in the paleomagnetic research. However, it is a complicated task hampered by some serious methodological difficulties. First, paleointensity experiments should be carefully designed using sufficient number of specimens, and accurate correction for remanence anisotropy, cooling rate effects, and non-linear TRM (NLT). Second, the basic assumption of the paleointensity method - that the natural remanence magnetization (NRM) is a stable thermoremanent magnetization (TRM) carried by single domain (SD) like particles - is hard to test using non-destructive methods. Third, the interpretation of the experimental results is non-unique leading to uncertainty in the final paleointensity calculation. These experimental difficulties compound with dating problems, which are not always easy to overcome. Here, we address each of the issues pointed above in order to construct a high-resolution archaeointensity curve of the Levant using a comprehensive dataset consisting of more than 2000 specimens from over 400 samples. The experimental difficulties are overcome by applying the same treatments to all specimens: Thellier-type IZZI protocol with pTRM checks every second step, and additional anisotropy, cooling rate, and NLT experiments. To ensure consistency, comparability, and objectivity of the interpretations we apply an automatic data analysis technique using a recently published open code computer program (PmagPy Thellier-GUI). We use strict selection criteria for the specimens/samples level and for the correction to screen out any unreliable data. For transparency, we make all the raw data, which include over 80,000 individual measurements, available in the MagIC database for the use of other researchers. We treat the dating problems by assigning a six-level quality scale (form controversial to excellent

  11. High-precision absolute coordinate measurement using frequency scanned interferometry

    International Nuclear Information System (INIS)

    We reported previously on measurements of absolute distance with frequency scanned interferometry (FSI) method [1, 2]. In this paper, we extend the FSI method into 2-dimensional and 3-dimensional high-precision absolute coordinate measurements using a single laser. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision on X and Y in 2- and in 3-dimensional measurements is confirmed to be below 1 μm, while the precision in Z (in 3D case) is found to be about 2 μm. The last one is limited by the accuracy of the available translational stage used in the tests. A much more powerful laser and a better real-time data acquirement system will be required in case of measurements of larger absolute distances

  12. Absolute brightness temperature measurements at 2.1-mm wavelength

    Science.gov (United States)

    Ulich, B. L.

    1974-01-01

    Absolute measurements of the brightness temperatures of the Sun, new Moon, Venus, Mars, Jupiter, Saturn, and Uranus, and of the flux density of DR21 at 2.1-mm wavelength are reported. Relative measurements at 3.5-mm wavelength are also preented which resolve the absolute calibration discrepancy between The University of Texas 16-ft radio telescope and the Aerospace Corporation 15-ft antenna. The use of the bright planets and DR21 as absolute calibration sources at millimeter wavelengths is discussed in the light of recent observations.

  13. An All Fiber White Light Interferometric Absolute Temperature Measurement System

    Directory of Open Access Journals (Sweden)

    Jeonggon Harrison Kim

    2008-11-01

    Full Text Available Recently the author of this article proposed a new signal processing algorithm for an all fiber white light interferometer. In this article, an all fiber white light interferometric absolute temperature measurement system is presented using the previously proposed signal processing algorithm. Stability and absolute temperature measurement were demonstrated. These two tests demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe and 0.0005 fringe, respectively. A hysteresis test from 373K to 873K was also presented. Finally, robustness of the sensor system towards laser diode temperature drift, AFMZI temperature drift and PZT non-linearity was demonstrated.

  14. Absolute angular calibration of a submarine km3 neutrino telescope

    International Nuclear Information System (INIS)

    A requirement for neutrino telescope is the ability to resolve point sources of neutrinos. In order to understand its resolving power a way to perform absolute angular calibration with muons is required. Muons produced by cosmic rays in the atmosphere offer an abundant calibration source. By covering a surface vessel with 200 modules of 5 m2 plastic scintillator a surface air shower array can be set up. Running this array in coincidence with a deep-sea km3 size neutrino detector, where the coincidence is defined by the absolute clock timing stamp for each event, would allow absolute angular calibration to be performed. Monte Carlo results simulating the absolute angular calibration of the km3 size neutrino detector will be presented. Future work and direction will be discussed.

  15. A proposal to measure absolute environmental sustainability in lifecycle assessment

    DEFF Research Database (Denmark)

    Bjørn, Anders; Margni, Manuele; Roy, Pierre-Olivier;

    2016-01-01

    in supporting decisions aimed at simultaneously reducing environmental impacts efficiently and maintaining or achieving environmental sustainability. We have demonstrated that LCA indicators can be modified from being relative to being absolute indicators of environmental sustainability. Further research should...

  16. Absolute value preconditioning for symmetric indefinite linear systems

    CERN Document Server

    Vecharynski, Eugene

    2011-01-01

    We introduce a novel strategy for constructing symmetric positive definite (SPD) preconditioners for linear systems with symmetric indefinite coefficient matrices. The strategy is motivated by the observation that the preconditioned minimal residual method with the inverse of the absolute value of the coefficient matrix as a preconditioner converges to the exact solution of the system in at most two steps. Neither the exact absolute value of the coefficient matrix, nor its exact inverse are computationally feasible to construct in general. However, as the proof of concept, we provide two practical examples of SPD preconditioners, which are based on the suggested approach, called absolute value preconditioning. The first example is for strictly (block) diagonally dominant coefficient matrices, where we propose using the inverse to the absolute value of the (block) diagonal as the preconditioner. Our second example is less intuitive. We consider a model problem with a shifted discrete negative Laplacian, and su...

  17. Absolute Value Boundedness, Operator Decomposition, and Stochastic Media and Equations

    Science.gov (United States)

    Adomian, G.; Miao, C. C.

    1973-01-01

    The research accomplished during this period is reported. Published abstracts and technical reports are listed. Articles presented include: boundedness of absolute values of generalized Fourier coefficients, propagation in stochastic media, and stationary conditions for stochastic differential equations.

  18. Preparation of an oakmoss absolute with reduced allergenic potential.

    Science.gov (United States)

    Ehret, C; Maupetit, P; Petrzilka, M; Klecak, G

    1992-06-01

    Synopsis Oakmoss absolute, an extract of the lichen Evernia prunastri, is known to cause allergenic skin reactions due to the presence of certain aromatic aldehydes such as atranorin, chloratranorin, ethyl hematommate and ethyl chlorohematommate. In this paper it is shown that treatment of Oakmoss absolute with amino acids such as lysine and/or leucine, lowers considerably the content of these allergenic constituents including atranol and chloratranol. The resulting Oakmoss absolute, which exhibits an excellent olfactive quality, was tested extensively in comparative studies on guinea pigs and on man. The results of the Guinea Pig Maximization Test (GPMT) and Human Repeated Insult Patch Test (HRIPT) indicate that, in comparison with the commercial test sample, the allergenicity of this new quality of Oakmoss absolute was considerably reduced, and consequently better skin tolerance of this fragrance for man was achieved. PMID:19272096

  19. Geomagnetic field intensity and inclination records from the Hawaiian long basaltic cores: geomagnetic implications

    Science.gov (United States)

    Laj, C. E.; Kissel, C.; Davies, C.; Gubbins, D.

    2009-12-01

    In the long basaltic cores drilled in the Big Island of Hawaii, the sub-horizontal orientation of the flows and their regular accumulation with time, which makes the continuity in time almost comparable with sediments, provides an excellent opportunity to obtain a detailed record of the absolute intensity and inclination of the geomagnetic field from a sequence of lava flows. Here, we report new paleointensity (Thellier and Thellier) and inclination determinations obtained from the analysis of 370 samples from 130 flows in the subaerial part of HSDP2. These new results are combined with previous results obtained from the other long basaltic cores in Hawaii (HSDP1, SOH4 and SOH1) all selected using a set of stringent paleointensity selection criteria (PICRIT-03). In a first step the Sharp and Renne age model was used for correlation of the records. In a second step correlation was refined using some characteristic features of the paleomagnetic records themselves (HSDP 1 and HSDP 2 in particular), which led to a slight modification of the Sharp and Renne age model. The age model was further improved by correlation with the sedimentary SINT-800 record. The results are consistent between these independent records, over the different time intervals where they overlap. This allows construction of the first accurate lava record of absolute intensity and inclination at Hawaii which overlap for almost 75% of this time interval these different records overlap, the results are very consistent and allow to construct an accurate lava record of absolute geomagnetic field intensity and inclination at Hawaii for the last 420 kyr based on at least two independent records over almost. The VADM undergoes large oscillations between about 3 and 16 10^22 A.m*2 with an average values of about 8 10^22 A m^2. When the values corresponding to recognized excursional periods are omitted, the inclination is on the average 29.6°, i.e. about 6° shallower than the GAD value. These results will

  20. Absolute Free Energies for Biomolecules in Implicit or Explicit Solvent

    Science.gov (United States)

    Berryman, Joshua T.; Schilling, Tanja

    Methods for absolute free energy calculation by alchemical transformation of a quantitative model to an analytically tractable one are discussed. These absolute free energy methods are placed in the context of other methods, and an attempt is made to describe the best practice for such calculations given the current state of the art. Calculations of the equilibria between the four free energy basins of the dialanine molecule and the two right- and left-twisted basins of DNA are discussed as examples.

  1. Establishment of Absolute Gravity Datum in CMONOC and Its Application

    OpenAIRE

    XING Lelin; LI Hui; Li, Jianguo; Zhang, Weimin; HE Zhitang

    2016-01-01

    The high accuracy absolute gravity datum covered the Chinese mainland area is established by using absolute gravity measurement data of one hundred stations in CMONOC(Crustal Movement Observation Network of China), the accuracy of each station is better than 5.0 μGal/a. The high accuracy gravity datum can be used for relative gravity measurements in adjustment, and the real gravity value can be determined from relative gravity measurement data of adjustment by using the gravity datum to avoid...

  2. Absolute Baseline for Testing of Electronic Distance Meters

    OpenAIRE

    Jaroslav Braun; Filip Dvořáček; Martin Štroner

    2014-01-01

    The paper deals with the construction and determination of coordinates of the absoluteEDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute TrackerAT401 (standard deviation of distance measurement: 5 μ m, standard deviation of anglemeasurement: 0.15 mgon), which is designed for very accurate industrial measurements,was used for our purpose. Lengths between the baseline points were determined with astandard deviation of 0.02 mm. The baseline is used for determining...

  3. Absolute Branching Fraction Measurements of Exclusive D^0 Semileptonic Decays

    CERN Document Server

    Coan, T E; Liu, F; Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dambasuren, E; Dorjkhaidav, O; Li, J; Menaa, N; Mountain, R; Nandakumar, R; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Briere, R A; Chen, G P; Chen, J; Ferguson, T; Tatishvili, G T; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Credé, V; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Pivarski, J; Phillips, E A; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shepherd, M R; Stroiney, S; Sun, W M; Urner, D; Wilksen, T; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stöck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; Williams, J; Wiss, J; Edwards, K W; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Gong, D T; Kubota, Y; Klein, T; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Dobbs, S; Metreveli, Z V; Seth, K K; Tomaradze, A G; Zweber, P; Ernst, J; Mahmood, A H; Severini, H; Asner, D M; Dytman, S A; Love, W; Mehrabyan, S S; Müller, J A; Savinov, V; Li, Z; López, A; Méndez, H; Ramírez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shibata, E I; Shipsey, I P J; Adams, G S; Chasse, M; Cravey, M; Cummings, J P; Danko, I; Napolitano, J; He, Q; Muramatsu, H; Park, C S; Park, W; Thorndike, E H

    2005-01-01

    With the first data sample collected by the CLEO-c detector at the psi(3770) resonance we have studied four exclusive semileptonic decays of the D0 meson. Our results include the first observation and absolute branching fraction measurement for D0 --> rho- e+ nu_e and improved measurements of the absolute branching fractions for D0 decays to K- e+ nu_e, pi- e+ nu_e, and K*- e+ nu_e.

  4. DIAGNOSTIC TEST FOR GARCH MODELS BASED ON ABSOLUTE RESIDUAL AUTOCORRELATIONS

    Directory of Open Access Journals (Sweden)

    Farhat Iqbal

    2013-10-01

    Full Text Available In this paper the asymptotic distribution of the absolute residual autocorrelations from generalized autoregressive conditional heteroscedastic (GARCH models is derived. The correct asymptotic standard errors for the absolute residual autocorrelations are also obtained and based on these results, a diagnostic test for checking the adequacy of GARCH-type models are developed. Our results do not depend on the existence of higher moments and is therefore robust under heavy-tailed distributions.

  5. The Pragmatics of "Unruly" Dative Absolutes in Early Slavic

    Directory of Open Access Journals (Sweden)

    Daniel E. Collins

    2011-08-01

    Full Text Available This chapter examines some uses of the dative absolute in Old Church Slavonic and in early recensional Slavonic texts that depart from notions of how Indo-European absolute constructions should behave, either because they have subjects coreferential with the (putative main-clause subjects or because they function as if they were main clauses in their own right. Such "noncanonical" absolutes have generally been written off as mechanistic translations or as mistakes by scribes who did not understand the proper uses of the construction. In reality, the problem is not with literalistic translators or incompetent scribes but with the definition of the construction itself; it is quite possible to redefine the Early Slavic dative absolute in a way that accounts for the supposedly deviant cases. While the absolute is generally dependent semantically on an adjacent unit of discourse, it should not always be regarded as subordinated syntactically. There are good grounds for viewing some absolutes not as dependent clauses but as independent sentences whose collateral character is an issue not of syntax but of the pragmatics of discourse.

  6. Method to obtain absolute impurity density profiles combining charge exchange and beam emission spectroscopy without absolute intensity calibrationa)

    Science.gov (United States)

    Kappatou, A.; Jaspers, R. J. E.; Delabie, E.; Marchuk, O.; Biel, W.; Jakobs, M. A.

    2012-10-01

    Investigation of impurity transport properties in tokamak plasmas is essential and a diagnostic that can provide information on the impurity content is required. Combining charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES), absolute radial profiles of impurity densities can be obtained from the CXRS and BES intensities, electron density and CXRS and BES emission rates, without requiring any absolute calibration of the spectra. The technique is demonstrated here with absolute impurity density radial profiles obtained in TEXTOR plasmas, using a high efficiency charge exchange spectrometer with high etendue, that measures the CXRS and BES spectra along the same lines-of-sight, offering an additional advantage for the determination of absolute impurity densities.

  7. Method to obtain absolute impurity density profiles combining charge exchange and beam emission spectroscopy without absolute intensity calibration

    Energy Technology Data Exchange (ETDEWEB)

    Kappatou, A.; Delabie, E. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, 3430 BE Nieuwegein (Netherlands); Jaspers, R. J. E.; Jakobs, M. A. [Science and Technology of Nuclear Fusion, Eindhoven University of Technology, 5600 MB Eindhoven (Netherlands); Marchuk, O.; Biel, W. [Institute for Energy and Climate Research, Forschungszentrum Julich GmbH, Trilateral Euregio Cluster, 52425 Julich (Germany)

    2012-10-15

    Investigation of impurity transport properties in tokamak plasmas is essential and a diagnostic that can provide information on the impurity content is required. Combining charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES), absolute radial profiles of impurity densities can be obtained from the CXRS and BES intensities, electron density and CXRS and BES emission rates, without requiring any absolute calibration of the spectra. The technique is demonstrated here with absolute impurity density radial profiles obtained in TEXTOR plasmas, using a high efficiency charge exchange spectrometer with high etendue, that measures the CXRS and BES spectra along the same lines-of-sight, offering an additional advantage for the determination of absolute impurity densities.

  8. Absolute neutrophil values in malignant patients on cytotoxic chemotherapy.

    Science.gov (United States)

    Madu, A J; Ibegbulam, O G; Ocheni, S; Madu, K A; Aguwa, E N

    2011-01-01

    A total of eighty patients with various malignancies seen between September 2008 and April 2009 at the University of Nigeria Teaching Hospital (UNTH) Ituku Ozalla, Enugu, Nigeria, had their absolute neutrophil counts, done at Days 0 and 12 of the first cycle of their various chemotherapeutic regimens. They were adult patients who had been diagnosed of various malignancies, consisting of Breast cancer 36 (45%), Non-Hodgkin's lymphoma 8 (10%), Hodgkin's lymphoma 13 (16.25%), Colorectal carcinoma 6 (7.5%), Multiple myeloma 7 (8.75%), Cervical carcinoma 1 (1.25%) and other malignancies 9 (11.25%), Manual counting of absolute neutrophil count was done using Turks solution and improved Neubauer counting chamber and Galen 2000 Olympus microscope. The socio demographic data of the patients were assessed from a questionnaire. There were 27 males (33.75%) and 53 females (66.25%). Their ages ranged from 18 - 80 years with a median of 45 years. The mean absolute neutrophil count of the respondents pre-and post chemotherapy was 3.7 +/- 2.1 x 10(9)/L and 2.5 +/- 1.6 x 10(9)/L respectively. There were significant differences in both the absolute neutrophil count (p=0.00) compared to the pre-chemotherapy values. Chemotherapeutic combinations containing cyclophosphamide and Adriamycin were observed to cause significant reduction in absolute neutrophil.

  9. Relative and absolute risk in epidemiology and health physics

    International Nuclear Information System (INIS)

    The health risk from ionizing radiation commonly is expressed in two forms: (1) the relative risk, which is the percentage increase in natural disease rate and (2) the absolute or attributable risk which represents the difference between the natural rate and the rate associated with the agent in question. Relative risk estimates for ionizing radiation generally are higher than those expressed as the absolute risk. This raises the question of which risk estimator is the most appropriate under different conditions. The absolute risk has generally been used for radiation risk assessment, although mathematical combinations such as the arithmetic or geometric mean of both the absolute and relative risks, have also been used. Combinations of the two risk estimators are not valid because the absolute and relative risk are not independent variables. Both human epidemiologic studies and animal experimental data can be found to illustrate the functional relationship between the natural cancer risk and the risk associated with radiation. This implies that the radiation risk estimate derived from one population may not be appropriate for predictions in another population, unless it is adjusted for the difference in the natural disease incidence between the two populations

  10. Simple unbiased estimation of absolute free energies for biomolecules

    CERN Document Server

    Ytreberg, F M

    2005-01-01

    One reason that free energy difference calculations are notoriously difficult in molecular systems is due to insufficient conformational overlap, or similarity, between the two states or systems of interest. The degree of overlap is irrelevant, however, if the absolute free energy of each state can be computed. We present a method for calculating the absolute free energy that employs a simple construction of an exactly computable reference system which possesses high overlap with the state of interest. The approach requires only a physical ensemble of conformations generated via simulation, and an auxiliary calculation of approximately equal CPU cost. Moreover, the calculations can converge to the correct free energy value even when the physical ensemble is incomplete or improperly distributed. We use the approach to correctly predict free energies for test systems where the absolute values can be calculated exactly, and also to predict the conformational equilibrium for leucine dipeptide in GBSA implicit sol...

  11. The mixed Littlewood conjecture for pseudo-absolute values

    CERN Document Server

    Harrap, Stephen

    2010-01-01

    In this paper we prove the mixed Littlewood conjecture for a p-adic absolute value and any pseudo-absolute value with bounded ratios. More precisely we show that if p is a prime and D is a pseudo-absolute value sequence with elements divisible by finitely many primes not equal to p, and if the terms of D grow more slowly than the exponential of a polynomial then the infimum over natural numbers n of the quantity n.|n|_p.|n|_D.||nx|| equals 0 for all real x. Our proof relies on two deep results, a measure rigidity theorem due to Lindenstrauss and lower bounds for linear forms in logarithms due to Baker and Wustholz. We also deduce the answer to the related metric question of how fast the infimum above tends to zero, for almost every x.

  12. System and method for calibrating a rotary absolute position sensor

    Science.gov (United States)

    Davis, Donald R. (Inventor); Permenter, Frank Noble (Inventor); Radford, Nicolaus A (Inventor)

    2012-01-01

    A system includes a rotary device, a rotary absolute position (RAP) sensor generating encoded pairs of voltage signals describing positional data of the rotary device, a host machine, and an algorithm. The algorithm calculates calibration parameters usable to determine an absolute position of the rotary device using the encoded pairs, and is adapted for linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters. A method of calibrating the RAP sensor includes measuring the rotary position as encoded pairs of voltage signals, linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters, and calculating an absolute position of the rotary device using the calibration parameters. The calibration parameters include a positive definite matrix (A) and a center point (q) of the ellipse. The voltage signals may include an encoded sine and cosine of a rotary angle of the rotary device.

  13. An algorithm for estimating Absolute Salinity in the global ocean

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2009-02-01

    Full Text Available To date, density and other thermodynamic properties of seawater have been calculated from Practical Salinity, S P. It is more accurate however to use Absolute Salinity, S A (the mass fraction of dissolved material in seawater. Absolute Salinity S A can be expressed in terms of Practical Salinity S P as

    S A=(35.165 04 g kg-1/35S PS A(φ, λ, p

    where δ S A is the Absolute Salinity Anomaly as a function of longitude φ, latitude λ and pressure. When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, the Absolute Salinity Anomaly is zero. When seawater is not of standard composition, the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (φ, λ, p in the world ocean.

    To develop this algorithm we use the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. To expand our data set we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally. We approximate the laboratory-determined values of δ S A of the 811 seawater samples as a series of simple functions of the silicate concentration of the seawater sample and latitude; one function for each ocean basin. We use these basin-specific correlations and a digital atlas of silicate in the world ocean to deduce the Absolute Salinity

  14. Neural sensitivity to absolute and relative anticipated reward in adolescents.

    Science.gov (United States)

    Vaidya, Jatin G; Knutson, Brian; O'Leary, Daniel S; Block, Robert I; Magnotta, Vincent

    2013-01-01

    Adolescence is associated with a dramatic increase in risky and impulsive behaviors that have been attributed to developmental differences in neural processing of rewards. In the present study, we sought to identify age differences in anticipation of absolute and relative rewards. To do so, we modified a commonly used monetary incentive delay (MID) task in order to examine brain activity to relative anticipated reward value (neural sensitivity to the value of a reward as a function of other available rewards). This design also made it possible to examine developmental differences in brain activation to absolute anticipated reward magnitude (the degree to which neural activity increases with increasing reward magnitude). While undergoing fMRI, 18 adolescents and 18 adult participants were presented with cues associated with different reward magnitudes. After the cue, participants responded to a target to win money on that trial. Presentation of cues was blocked such that two reward cues associated with $.20, $1.00, or $5.00 were in play on a given block. Thus, the relative value of the $1.00 reward varied depending on whether it was paired with a smaller or larger reward. Reflecting age differences in neural responses to relative anticipated reward (i.e., reference dependent processing), adults, but not adolescents, demonstrated greater activity to a $1 reward when it was the larger of the two available rewards. Adults also demonstrated a more linear increase in ventral striatal activity as a function of increasing absolute reward magnitude compared to adolescents. Additionally, reduced ventral striatal sensitivity to absolute anticipated reward (i.e., the difference in activity to medium versus small rewards) correlated with higher levels of trait Impulsivity. Thus, ventral striatal activity in anticipation of absolute and relative rewards develops with age. Absolute reward processing is also linked to individual differences in Impulsivity. PMID:23544046

  15. Neural sensitivity to absolute and relative anticipated reward in adolescents.

    Directory of Open Access Journals (Sweden)

    Jatin G Vaidya

    Full Text Available Adolescence is associated with a dramatic increase in risky and impulsive behaviors that have been attributed to developmental differences in neural processing of rewards. In the present study, we sought to identify age differences in anticipation of absolute and relative rewards. To do so, we modified a commonly used monetary incentive delay (MID task in order to examine brain activity to relative anticipated reward value (neural sensitivity to the value of a reward as a function of other available rewards. This design also made it possible to examine developmental differences in brain activation to absolute anticipated reward magnitude (the degree to which neural activity increases with increasing reward magnitude. While undergoing fMRI, 18 adolescents and 18 adult participants were presented with cues associated with different reward magnitudes. After the cue, participants responded to a target to win money on that trial. Presentation of cues was blocked such that two reward cues associated with $.20, $1.00, or $5.00 were in play on a given block. Thus, the relative value of the $1.00 reward varied depending on whether it was paired with a smaller or larger reward. Reflecting age differences in neural responses to relative anticipated reward (i.e., reference dependent processing, adults, but not adolescents, demonstrated greater activity to a $1 reward when it was the larger of the two available rewards. Adults also demonstrated a more linear increase in ventral striatal activity as a function of increasing absolute reward magnitude compared to adolescents. Additionally, reduced ventral striatal sensitivity to absolute anticipated reward (i.e., the difference in activity to medium versus small rewards correlated with higher levels of trait Impulsivity. Thus, ventral striatal activity in anticipation of absolute and relative rewards develops with age. Absolute reward processing is also linked to individual differences in Impulsivity.

  16. Absolute Baseline for Testing of Electronic Distance Meters

    Directory of Open Access Journals (Sweden)

    Jaroslav Braun

    2014-06-01

    Full Text Available The paper deals with the construction and determination of coordinates of the absoluteEDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute TrackerAT401 (standard deviation of distance measurement: 5 μ m, standard deviation of anglemeasurement: 0.15 mgon, which is designed for very accurate industrial measurements,was used for our purpose. Lengths between the baseline points were determined with astandard deviation of 0.02 mm. The baseline is used for determining systematic and randomerrors of distance meters and for accuracy of distance meters at short distances commonin engineering surveying for purposes of mechanical engineering.

  17. Absolute Branching Fraction Measurements of Exclusive D^+ Semileptonic Decays

    CERN Document Server

    Huang, G S; Pavlunin, V; Sanghi, B; Shipsey, I P J; Adams, G S; Chasse, M; Cravey, M; Cummings, J P; Danko, I; Napolitano, J; He, Q; Muramatsu, H; Park, C S; Park, W; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F; Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dambasuren, E; Dorjkhaidav, O; Li, J; Menaa, N; Mountain, R; Nandakumar, R; Randrianarivony, K; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Briere, R A; Chen, G P; Chen, J; Ferguson, T; Tatishvili, G T; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Credé, V; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Phillips, E A; Pivarski, J; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shi, X; Shepherd, M R; Stroiney, S; Sun, W M; Urner, D; Weaver, K M; Wilksen, T; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stöck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; Williams, J; Wiss, J; Edwards, K W; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Gong, D T; Hietala, J; Kubota, Y; Klein, T; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Dobbs, S; Metreveli, Z V; Seth, K K; Tomaradze, A G; Zweber, P; Ernst, J; Mahmood, A H; Severini, H; Asner, D M; Dytman, S A; Love, W; Mehrabyan, S S; Müller, J A; Savinov, V; Li, Z; López, A; Méndez, H; Ramírez, J

    2005-01-01

    Using data collected at the psi(3770) resonance with the CLEO-c detector at the Cornell e+e- storage ring, we present improved measurements of the absolute branching fractions of D+ decays to K0B e+ nu_e, pi0 e+ nu_e, K0B* e+ nu_e, and rho0 e+ nu_e, and the first observation and absolute branching fraction measurement of D+ --> omega e+ nu_e. We also report the most precise tests to date of isospin invariance in semileptonic D0 and D+ decays.

  18. On the absolute value of the air-fluorescence yield

    OpenAIRE

    Rosado Vélez, Jaime; Blanco Ramos, Francisco; Arqueros Martínez, Fernando

    2014-01-01

    The absolute value of the air-fluorescence yield is a key parameter for the energy reconstruction of extensive air showers registered by fluorescence telescopes. In previous publications, we reported a detailed Monte Carlo simulation of the air-fluorescence generation that allowed the theoretical evaluation of this parameter. This simulation has been upgraded in the present work. As a result, we determined an updated absolute value of the fluorescence yield of 7.9 +/- 2.0 ph/MeV for the band ...

  19. Properties of Absolute Stability in the Presence of Time Lags

    Directory of Open Access Journals (Sweden)

    M. De la Sen

    2005-01-01

    Full Text Available This study is concerned with the properties of absolute stability independent of the delays of time-delay systems, possessing non commensurate internal point delays, for any nonlinearity satisfying a Popov’s- type time positivity inequality. That property holds if an associate delay-free system is absolutely stable and the size of the delayed dynamics is sufficiently small. The results are obtained for nonlinearities belonging to sectors [0, k] and [h, k+h], and are based on a parabola test type.

  20. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  1. Absolute small-angle measurement based on optical feedback interferometry

    Institute of Scientific and Technical Information of China (English)

    Jingang Zhong; Xianhua Zhang; Zhixiang Ju

    2008-01-01

    We present a simple but effective method for small-angle measurement based on optical feedback inter-ferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe amplitude point, so this method can also achieve absolute angle measurement. In order to verify the method, we construct an angle measurement system. The Fourier-transform method is used to analysis the interference signal. Rotation angles are experimentally measured with a resolution of 10-6 rad and a measurement range of approximately from -0.0007 to +0.0007 rad.

  2. Non-Invasive Method of Determining Absolute Intracranial Pressure

    Science.gov (United States)

    Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor); Hargens, Alan E. (Inventor)

    2004-01-01

    A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.

  3. Perceiving pitch absolutely: Comparing absolute and relative pitch possessors in a pitch memory task

    Directory of Open Access Journals (Sweden)

    Schlaug Gottfried

    2009-08-01

    Full Text Available Abstract Background The perceptual-cognitive mechanisms and neural correlates of Absolute Pitch (AP are not fully understood. The aim of this fMRI study was to examine the neural network underlying AP using a pitch memory experiment and contrasting two groups of musicians with each other, those that have AP and those that do not. Results We found a common activation pattern for both groups that included the superior temporal gyrus (STG extending into the adjacent superior temporal sulcus (STS, the inferior parietal lobule (IPL extending into the adjacent intraparietal sulcus (IPS, the posterior part of the inferior frontal gyrus (IFG, the pre-supplementary motor area (pre-SMA, and superior lateral cerebellar regions. Significant between-group differences were seen in the left STS during the early encoding phase of the pitch memory task (more activation in AP musicians and in the right superior parietal lobule (SPL/intraparietal sulcus (IPS during the early perceptual phase (ITP 0–3 and later working memory/multimodal encoding phase of the pitch memory task (more activation in non-AP musicians. Non-significant between-group trends were seen in the posterior IFG (more in AP musicians and the IPL (more anterior activations in the non-AP group and more posterior activations in the AP group. Conclusion Since the increased activation of the left STS in AP musicians was observed during the early perceptual encoding phase and since the STS has been shown to be involved in categorization tasks, its activation might suggest that AP musicians involve categorization regions in tonal tasks. The increased activation of the right SPL/IPS in non-AP musicians indicates either an increased use of regions that are part of a tonal working memory (WM network, or the use of a multimodal encoding strategy such as the utilization of a visual-spatial mapping scheme (i.e., imagining notes on a staff or using a spatial coding for their relative pitch height for pitch

  4. Verifying the mesozoic dipole low hypothesis by the Siberian trap data

    Science.gov (United States)

    Shcherbakova, V. V.; Zhidkov, G. V.; Shcherbakov, V. P.; Latyshev, A. V.; Fetisova, A. M.

    2015-05-01

    A complex study is carried out for the collection of trap rocks sampled from two sequences in the geographically distant regions of the Siberian trap province: the Ergalakh section (Norilsk region) and Tyvankitskii and Delkanskii formations (Maymecha-Kotuy region). The magnetic and thermomagnetic properties are studied, petrographic and microscopic investigations are carried out, the paleointensities are determined, and the domain structure of ferromagnetics is assessed using the Day diagram and the thermomagnetic criterion. It is shown that small single-domain and/or pseudo-single-domain grains are the carriers of remanent magnetization. The absolute paleointensities H anc are determined by the Thellier-Coe method with test heating of the samples to lower temperatures (check-point procedure). The paleointensity estimates that meet the modern reliability criteria are obtained in more than 130 samples. The mean H anc values in the lava flows from the Ergalakh section and the TyvankittskiiFormation, as well as in samples from the Delkanskii Formation, vary within 2.1-24.6 mkT, which is considerably lower than the present magnetic field at the sampling site (˜ 50 mkT). The corresponding mean VDM values in these sites vary within (0.54-3.2) × 1022 Am2 (with a dispersion of ˜0.9 × 1022 Am2), which is far lower than the mean VDM value (˜8 × 1022 Am2) in the Late Cenozoic. The agreement of low H anc and VDM determined in the Ergalakh section, Tyvankitskii, and Delkanskii formations with the previous similar data on the traps (Solodovnikov, 1994; Heunemann et al., 2004; Shcherbakova et al., 2005; 2013) supports the Mesozoic Dipole Low (MDL) hypothesis. In the Ergalakh section, low and extremely low H anc (11.2 and 2.7 mkT) are determined in two pulses (five flows) of the Ivakinskii Formation, which precedes the geomagnetic reversal. This probably indicates that these flows recorded a sharp decrease in H anc prior to the geomagnetic reversal (or at its beginning

  5. Absolute determination of inelastic mean-free paths and surface excitation parameters by absolute reflection electron energy loss spectrum analysis

    Science.gov (United States)

    Nagatomi, T.; Goto, K.

    2005-11-01

    An analytical approach was proposed for simultaneously determining an inelastic mean-free path (IMFP) and a surface excitation parameter (SEP) with absolute units by the analysis of an absolute experimental reflection electron energy loss spectrum. The IMFPs and SEPs in Ni were deduced for electrons of 300 to 3000 eV. The obtained IMFPs were in good agreement with those calculated using the TPP-2M equation. The Chen-type empirical formula was proposed for determining the SEP. The results confirmed the applicability of the present approach for determining the IMFP and SEP for medium-energy electrons.

  6. Partial sums of arithmetical functions with absolutely convergent Ramanujan expansions

    Indian Academy of Sciences (India)

    BISWAJYOTI SAHA

    2016-08-01

    For an arithmetical function $f$ with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the $\\sum_{n\\leq N}$ f(n)$ with explicit error term. As a corollary we obtain new results about sum-of-divisors functions and Jordan’s totient functions.

  7. Absolute cross-section of turbojet aviation engine calculation

    OpenAIRE

    Ryabokon, Evgen

    2012-01-01

    The calculation method of three-dimensional model of turbojet aviation engine is offered, thus the form of turbine vanes with spiralling is described like parametric surface. The method allows make the calculation of absolute cross-section (ACS) of turbojet aviation engines with different geometrical parameters. The calculation results of ACS of aviation engine are presented.

  8. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    Science.gov (United States)

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  9. Gray- and White-Matter Anatomy of Absolute Pitch Possessors

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Chakravarty, Mallar;

    2015-01-01

    Absolute pitch (AP), the ability to identify a musical pitch without a reference, has been examined behaviorally in numerous studies for more than a century, yet only a few studies have examined the neuroanatomical correlates of AP. Here, we used MRI and diffusion tensor imaging to investigate...

  10. Absolute magnitudes and phase coefficients of trans-Neptunian objects

    CERN Document Server

    Alvarez-Candal, A; Ortiz, J L; Duffard, R; Morales, N; Santos-Sanz, P; Thirouin, A; Silva, J S

    2015-01-01

    Context: Accurate measurements of diameters of trans-Neptunian objects are extremely complicated to obtain. Thermal modeling can provide good results, but accurate absolute magnitudes are needed to constrain the thermal models and derive diameters and geometric albedos. The absolute magnitude, Hv, is defined as the magnitude of the object reduced to unit helio- and geocentric distances and a zero solar phase angle and is determined using phase curves. Phase coefficients can also be obtained from phase curves. These are related to surface properties, yet not many are known. Aims: Our objective is to measure accurate V band absolute magnitudes and phase coefficients for a sample of trans-Neptunian objects, many of which have been observed, and modeled, within the 'TNOs are cool' program, one of Herschel Space Observatory key projects. Methods: We observed 56 objects using the V and R filters. These data, along with those available in the literature, were used to obtain phase curves and measure V band absolute m...

  11. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    Prem Chandra

    2001-05-01

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  12. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  13. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.

    2011-04-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional support for our model of enantioinduction in the palladium(II)-catalyzed oxidative kinetic resolution of secondary alcohols. © 2010 Elsevier Ltd. All rights reserved.

  14. Modeling and forecasting outliers and level shifts in absolute returns

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); M.J. van der Leij (Marco); R. Paap (Richard)

    2001-01-01

    textabstractDue to high and low volatility periods, time series of absolute returns experience temporary level shifts (that is, periods with outliers) which differ in length and size. In this paper we put forward a new model which can describe and forecast the location and size of such level shifts.

  15. Determination of absolute structure using Bayesian statistics on Bijvoet differences

    NARCIS (Netherlands)

    Hooft, R.W.W.; Straver, L.H.; Spek, A.L.

    2008-01-01

    A new probabilistic approach is introduced for the determination of the absolute structure of a compound which is known to be enantiopure based on Bijvoet-pair intensity differences. The new method provides relative probabilities for different models of the chiral composition of the structure. The o

  16. An improved generalized Newton method for absolute value equations.

    Science.gov (United States)

    Feng, Jingmei; Liu, Sanyang

    2016-01-01

    In this paper, we suggest and analyze an improved generalized Newton method for solving the NP-hard absolute value equations [Formula: see text] when the singular values of A exceed 1. We show that the global and local quadratic convergence of the proposed method. Numerical experiments show the efficiency of the method and the high accuracy of calculation. PMID:27462490

  17. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2015-01-01

    The global absolute poverty rates of the World Bank demonstrate a continued decline of poverty in developing countries between 1983 and 2012. However, the methodology applied to derive these results has received extensive criticism by scholars for requiring the application of PPP exchange rates and

  18. Absolute localization of vibrotactile stimuli on the torso

    NARCIS (Netherlands)

    Erp, J.B.F. van

    2008-01-01

    Vibrotactile mobility systems present spatial information such as the direction of a waypoint through a localized vibration on the torso. Using these systems requires the ability to determine the absolute location of the stimulus. Because data are available only on the ability to determine the relat

  19. Estimation of Transition Probabilities Using Median Absolute Deviations

    OpenAIRE

    Kim, C. S.; Schaible, Glenn D.

    1988-01-01

    The probability-constrained minimum absolute deviations (MAD) estimator appears to be superior to the probability-constrained quadratic programming estimator in estimating transition probabilities with limited aggregate time series data Futhermore, one can reduce the number of columns in the probability-constrained MAD simplex tableau by adopting the median property

  20. Mathematical Model for Absolute Magnetic Measuring Systems in Industrial Applications

    Science.gov (United States)

    Fügenschuh, Armin; Fügenschuh, Marzena; Ludszuweit, Marina; Mojsic, Aleksandar; Sokół, Joanna

    2015-09-01

    Scales for measuring systems are either based on incremental or absolute measuring methods. Incremental scales need to initialize a measurement cycle at a reference point. From there, the position is computed by counting increments of a periodic graduation. Absolute methods do not need reference points, since the position can be read directly from the scale. The positions on the complete scales are encoded using two incremental tracks with different graduation. We present a new method for absolute measuring using only one track for position encoding up to micrometre range. Instead of the common perpendicular magnetic areas, we use a pattern of trapezoidal magnetic areas, to store more complex information. For positioning, we use the magnetic field where every position is characterized by a set of values measured by a hall sensor array. We implement a method for reconstruction of absolute positions from the set of unique measured values. We compare two patterns with respect to uniqueness, accuracy, stability and robustness of positioning. We discuss how stability and robustness are influenced by different errors during the measurement in real applications and how those errors can be compensated.

  1. Absolute magnitudes and phase coefficients of trans-Neptunian objects

    Science.gov (United States)

    Alvarez-Candal, A.; Pinilla-Alonso, N.; Ortiz, J. L.; Duffard, R.; Morales, N.; Santos-Sanz, P.; Thirouin, A.; Silva, J. S.

    2016-02-01

    Context. Accurate measurements of diameters of trans-Neptunian objects (TNOs) are extremely difficult to obtain. Thermal modeling can provide good results, but accurate absolute magnitudes are needed to constrain the thermal models and derive diameters and geometric albedos. The absolute magnitude, HV, is defined as the magnitude of the object reduced to unit helio- and geocentric distances and a zero solar phase angle and is determined using phase curves. Phase coefficients can also be obtained from phase curves. These are related to surface properties, but only few are known. Aims: Our objective is to measure accurate V-band absolute magnitudes and phase coefficients for a sample of TNOs, many of which have been observed and modeled within the program "TNOs are cool", which is one of the Herschel Space Observatory key projects. Methods: We observed 56 objects using the V and R filters. These data, along with those available in the literature, were used to obtain phase curves and measure V-band absolute magnitudes and phase coefficients by assuming a linear trend of the phase curves and considering a magnitude variability that is due to the rotational light-curve. Results: We obtained 237 new magnitudes for the 56 objects, six of which were without previously reported measurements. Including the data from the literature, we report a total of 110 absolute magnitudes with their respective phase coefficients. The average value of HV is 6.39, bracketed by a minimum of 14.60 and a maximum of -1.12. For the phase coefficients we report a median value of 0.10 mag per degree and a very large dispersion, ranging from -0.88 up to 1.35 mag per degree.

  2. Absolute V-R colors of trans-Neptunian objects

    Science.gov (United States)

    Alvarez-Candal, Alvaro; Ayala-Loera, Carmen; Ortiz, Jose-Luis; Duffard, Rene; Estela, Fernandez-Valenzuela; Santos-Sanz, Pablo

    2016-10-01

    The absolute magnitude of a minor body is the apparent magnitude that the body would have if observed from the Sun at a distance of 1AU. Absolute magnitudes are measured using phase curves, showing the change of the magnitude, normalized to unit helio and geo-centric distance, vs. phase angle. The absolute magnitude is then the Y-intercept of the curve. Absolute magnitudes are related to the total reflecting surface of the body and thus bring information of its size, coupled with the reflecting properties.Since 2011 our team has been collecting data from several telescopes spread in Europe and South America. We complemented our data with those available in the literature in order to construct phase curves of trans-Neptunian objects with at least three points. In a first release (Alvarez-Candal et al. 2016, A&A, 586, A155) we showed results for 110 trans-Neptunian objects using V magnitudes only, assuming an overall linear trend and taking into consideration rotational effects, for objects with known light-curves.In this contribution we show results for more than 130 objects, about 100 of them with phase curves in two filters: V and R. We compute absolute magnitudes and phase coefficients in both filters, when available. The average values are HV = 6.39 ± 2.37, βV = (0.09 ± 0.32) mag per degree, HR = 5.38 ± 2.30, and βR = (0.08 ± 0.42) mag per degree.

  3. Holocene geomagnetic field intensity variations: Contribution from the low latitude Canary Islands site

    Science.gov (United States)

    Kissel, C.; Laj, C.; Rodriguez-Gonzalez, A.; Perez-Torrado, F.; Carracedo, J. C.; Wandres, C.

    2015-11-01

    New absolute paleomagnetic intensity (PI) are investigated from 37 lava flows located at Tenerife and Gran Canaria (Canary Islands). They complete previously published directional results from the same flows and therefore allow to examine the time variations of the full geomagnetic vector. Twenty-eight flows are radiocarbon dated between 1706 AD and about 13 200 BC and one is historical. Eight other flows are not dated but they have stratigraphic links with the dated flows and archeomagnetic ages had been attributed to them based on their paleomagnetic directions. Various mineralogical analyses were conducted, giving access to the nature of the magnetic minerals and to their grain size. We performed the original Thellier and Thellier paleointensity (PI) experiments with a success rate of about 65% coupling this experiment with the strict set of selection criteria PICRIT-03. The mean PIs at the flow level are based on 3 to 12 independent PI determinations except for one site in which only one reliable determination could be obtained. The data indicate some variability in the local field intensity with a prominent PI peak centered around 600 BC and reaching 80 μT (VADM 16 ×1022 Am2), documented for the first time in this region. Combined with the published data obtained from western Africa, Spain, Portugal, Morocco and the Azores within a 2000 km-radius around the Canary Islands, our data allow to construct a curve illustrating the Earth magnetic field intensity fluctuations for Southwestern Europe/Western Africa. This curve, compared to the one produced for the Middle East and one calculated for Central Asia shows that maximum intensity patches have a very large geographical extent. They do not yet appear clearly in the models of variations of the dipolar field intensity.

  4. Technique of absolute efficiency determination for gamma radiation semiconductor detectors

    International Nuclear Information System (INIS)

    Simple technique is suggested to determine the absolute efficiency (E) of semiconductor detectors (SCD) which employes low-intensity neutron sources wide spread in scientific laboratories. The technique is based on using radioactive nuclide gamma radiation in decay chains of heavy element fission fragments, uranium-235, for example. Cumulative yields of a number of nulcides following heavy element fission are measured to a high accuracy (1-5%), which permits to . the value E is determined for a wide energy range (from X- ray to some MeV); using a nuclide with a well known decay scheme and measured to a high accuracy cumulative yield 140La, for example, one can calibrate in absolute values comparatively easily obtained plots of the SCD relative efficiency. The technique allows to determine the E value for extended plane (and volumetric) sources of an arbitrary form. Some nuclides, convenient for the determination of E, and their nuclear characteristics are tabulated

  5. Beam energy absolute measurement using K-edge absorption spectrometers

    International Nuclear Information System (INIS)

    A method is presented of absolute energy measurement with an accuracy of triangle Ε ∼ 10-4Εo by direct measurement of the bend angle in a high-precision magnetic dipole using two opposite-direction short (about 2 mm long) high-field-intensity magnets (bar Β dipole much-lt Βshortmag) installed at each end and two K-edge absorption spectrometers. Using these spectrometers and the hard x-ray synchrotron radiation created by the short magnets, a bend angle of 4.5 arc deg for the CEBAF energy bandwidth can be measured with an accuracy of a few units of 10-6 rad, and the main sources of systematic errors are the absolute measurement of the field integral and the determination of the centroid of the synchrotron beam at a wavelength equal to the K-edge absorption of the chosen substance

  6. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  7. Henry More and the development of absolute time.

    Science.gov (United States)

    Thomas, Emily

    2015-12-01

    This paper explores the nature, development and influence of the first English account of absolute time, put forward in the mid-seventeenth century by the 'Cambridge Platonist' Henry More. Against claims in the literature that More does not have an account of time, this paper sets out More's evolving account and shows that it reveals the lasting influence of Plotinus. Further, this paper argues that More developed his views on time in response to his adoption of Descartes' vortex cosmology and cosmogony, providing new evidence of More's wider project to absorb Cartesian natural philosophy into his Platonic metaphysics. Finally, this paper argues that More should be added to the list of sources that later English thinkers - including Newton and Samuel Clarke - drew on in constructing their absolute accounts of time. PMID:26568082

  8. Correction due to finite speed of light in absolute gravimeters

    CERN Document Server

    Nagornyi, V D; Zanimonskiy, Y Y

    2010-01-01

    Correction due to finite speed of light is among the most inconsistent ones in absolute gravimetry. Formulas reported by different authors yield corrections scattered up to 8 $\\mu$Gal with no obvious reasons. The problem, though noted before, has never been studied, and nowadays the correction is rather postulated than rigorously proven. In this paper we investigate the problem from several prospectives, find the corrections for different types of absolute gravimeters, and establish relationships between different ways of implement them. The obtained results enabled us to analyze and understand the discrepancies in the results of other authors. We found that the correction derived from the Doppler effect is accountable only for $\\tfrac{2}{3}$ of the total correction due to finite speed of light, if no signal delays are considered. Another major source of inconsistency was found in the tacit use of simplified trajectory models.

  9. From Hubble's Next Generation Spectral Library (NGSL) to Absolute Fluxes

    Science.gov (United States)

    Heap, S. R.; Lindler, D.

    2016-05-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R˜1000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18–1.03 μ. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsl/. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We have therefore developed an observing procedure, data-reduction procedure, and correction algorithms that should yield fluxes with uncertainties less than 1%.

  10. Flow rate calibration for absolute cell counting rationale and design.

    Science.gov (United States)

    Walker, Clare; Barnett, David

    2006-05-01

    There is a need for absolute leukocyte enumeration in the clinical setting, and accurate, reliable (and affordable) technology to determine absolute leukocyte counts has been developed. Such technology includes single platform and dual platform approaches. Derivations of these counts commonly incorporate the addition of a known number of latex microsphere beads to a blood sample, although it has been suggested that the addition of beads to a sample may only be required to act as an internal quality control procedure for assessing the pipetting error. This unit provides the technical details for undertaking flow rate calibration that obviates the need to add reference beads to each sample. It is envisaged that this report will provide the basis for subsequent clinical evaluations of this novel approach. PMID:18770842

  11. Enumeration of absolute cell counts using immunophenotypic techniques.

    Science.gov (United States)

    Mandy, F; Brando, B

    2001-05-01

    Absolute counting of cells or cell subsets has a number of significant clinical applications: monitoring the disease status of HIV-infected patients, enumerating residual white blood cells in leukoreduced blood products, and assessing immunodeficiency in a variety of situations. The single-platform method (flow cytometry alone) has emerged as the method of choice for absolute cell enumeration. This technology counts only the cells of interest in a precisely determined blood volume. Exact cell identification is accomplished by a logical electronic gating algorithm capable of identifying lineage-specific immunofluorescent markers. Exclusion of unwanted cells is automatic. This extensive and detailed unit presents protocols for both volumetric and flow-rate determination of residual white blood cells and of leukocyte subsets. PMID:18770719

  12. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Science.gov (United States)

    Sorri, J.; Greenlees, P. T.; Papadakis, P.; Konki, J.; Cox, D. M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P. J.; Barton, C. J.; Jenkins, D. G.

    2016-03-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  13. Combinatorial Selection and Least Absolute Shrinkage via the CLASH Algorithm

    CERN Document Server

    Kyrillidis, Anastasios

    2012-01-01

    The least absolute shrinkage and selection operator (LASSO) for linear regression exploits the geometric interplay of the $\\ell_2$-data error objective and the $\\ell_1$-norm constraint to arbitrarily select sparse models. Guiding this uninformed selection process with sparsity models has been precisely the center of attention over the last decade in order to improve learning performance. To this end, we alter the selection process of LASSO to explicitly leverage combinatorial sparsity models (CSMs) via the combinatorial selection and least absolute shrinkage (CLASH) operator. We provide concrete guidelines how to leverage combinatorial constraints within CLASH, and characterize CLASH's guarantees as a function of the set restricted isometry constants of the sensing matrix. Finally, our experimental results show that CLASH can outperform both LASSO and model-based compressive sensing in sparse estimation.

  14. Parameterized Absolute Parallelism: A Geometry for Physical Applications

    OpenAIRE

    Wanas, M. I.

    2000-01-01

    Absolute parallelism (AP) geometry is frequently used for physical applications. Although it is wider than Riemannian geometry, it has two main defects. The first is that its path equation does not represent physical trajectories of any test particle. The second is the identical vanishing of its curvature tensor. The present work shows that parameterizing this geometry would solve the two problems. Furthermore, the resulting parameterized AP-structure is more general than both the conventiona...

  15. Parameterized Absolute Parallelism: A Geometry for Physical Applications

    OpenAIRE

    WANAS, Mamdouh Ishaac

    2000-01-01

    Absolute parallelism (AP) geometry is frequently used for physical applications. Although it is wider than the Riemannian geometry, it has two main defects. The first is that its path equation does not represent physical trajectories of any test particle. The second is the identical vanishing of its curvature tensor. The present work shows that parameterizing this geometry would solve the two problems. Furthermore, the resulting parameterized (AP)-structure is more general than both the conve...

  16. ABSTRACT FUNCTIONS OF BOUNDED VARIATION AND ABSOLUTE CONTINUITY

    Institute of Scientific and Technical Information of China (English)

    WuCongxin; LiuTiefu

    1994-01-01

    As well known that in 1938,I. M. Gelfand firstly introduced abstract functions of bounded variation from [a,b] to a Banach space. After Gelfand's work,many mathematicians investigated various properties and of this kind of abstract functions, and also paid attention to the abstract functions of absolute continuity In this paper, we summarize to explain our work [1-17] about this topic.

  17. The Romantic subject as an absolutely autonomous individual:

    OpenAIRE

    Cunta, Miljana

    2004-01-01

    This essay deals with the Romantic subject as a philosophical and literary category. Recognizing the diversity and complexity of literary production in the Romantic period, this study does not attempt to treat all the many aspect sof this subject, but it instead focuses upon a few: the role of nature,the status of imagination, and the subject's relation to the transcendental reality. In its relation to these issues, the Romantic subject appears as an absolutely autonomous individual, one who ...

  18. Absolute Asymmetric Synthesis: The Origin, Control, and Amplification of Chirality

    OpenAIRE

    Delden, Richard A. van; Feringa, Bernard

    1999-01-01

    One of the fundamental and intriguing aspects of life is the homochirality of the essential molecules. From the early days of stereochemistry, the origin of chirality in biological systems has been a challenge to the chemical sciences and numerous theories and experiments have been reported. Despite the great progress in asymmetric synthesis, there are only a few genuine absolute asymmetric syntheses known today. Novel approaches based on the interplay of molecular biology, organic chemistry,...

  19. On the Absolute Continuity of the Blackwell Measure

    Science.gov (United States)

    Bárány, Balázs; Kolossváry, István

    2015-04-01

    In 1957, Blackwell expressed the entropy of hidden Markov chains using a measure which can be characterised as an invariant measure for an iterated function system with place-dependent weights. This measure, called the Blackwell measure, plays a central role in understanding the entropy rate and other important characteristics of fundamental models in information theory. We show that for a suitable set of parameter values the Blackwell measure is absolutely continuous for almost every parameter in the case of binary symmetric channels.

  20. Absolute cross-section normalization of magnetic neutron scattering data

    OpenAIRE

    Xu, Guangyong; Xu, Zhijun; Tranquada, J. M.

    2013-01-01

    We discuss various methods to obtain the resolution volume for neutron scattering experiments, in order to perform absolute normalization on inelastic magnetic neutron scattering data. Examples from previous experiments are given. We also try to provide clear definitions of a number of physical quantities which are commonly used to describe neutron magnetic scattering results, including the dynamic spin correlation function and the imaginary part of the dynamic susceptibility. Formulas that c...

  1. Blastic plasmacytoid dendritic cell neoplasm with absolute monocytosis at presentation

    Directory of Open Access Journals (Sweden)

    Jaworski JM

    2015-02-01

    Full Text Available Joseph M Jaworski,1,2 Vanlila K Swami,1 Rebecca C Heintzelman,1 Carrie A Cusack,3 Christina L Chung,3 Jeremy Peck,3 Matthew Fanelli,3 Micheal Styler,4 Sanaa Rizk,4 J Steve Hou1 1Department of Pathology and Laboratory Medicine, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 2Department of Pathology, Mercy Fitzgerald Hospital, Darby, PA, USA; 3Department of Dermatology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 4Department of Hematology/Oncology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Blastic plasmacytoid dendritic cell neoplasm is an uncommon malignancy derived from precursors of plasmacytoid dendritic cells. Nearly all patients present initially with cutaneous manifestations, with many having extracutaneous disease additionally. While response to chemotherapy initially is effective, relapse occurs in most, with a leukemic phase ultimately developing. The prognosis is dismal. While most of the clinical and pathologic features are well described, the association and possible prognostic significance between peripheral blood absolute monocytosis (>1.0 K/µL and blastic plasmacytoid dendritic cell neoplasm have not been reported. We report a case of a 68-year-old man who presented with a rash for 4–5 months. On physical examination, there were multiple, dull-pink, indurated plaques on the trunk and extremities. Complete blood count revealed thrombocytopenia, absolute monocytosis of 1.7 K/µL, and a negative flow cytometry study. Biopsy of an abdominal lesion revealed typical features of blastic plasmacytoid dendritic cell neoplasm. Patients having both hematologic and nonhematologic malignancies have an increased incidence of absolute monocytosis. Recent studies examining Hodgkin and non-Hodgkin lymphoma patients have suggested that this is a negative prognostic factor. The association between

  2. Concave Minimization for Sparse Solutions of Absolute Value Equations

    Institute of Scientific and Technical Information of China (English)

    刘晓红; 樊婕; 李文娟

    2016-01-01

    Based on concave function, the problem of finding the sparse solution of absolute value equations is relaxed to a concave programming, and its corresponding algorithm is proposed, whose main part is solving a series of linear programming. It is proved that a sparse solution can be found under the assumption that the connected matrixes have range space property(RSP). Numerical experiments are also conducted to verify the efficiency of the proposed algorithm.

  3. BMO solvability and absolute continuity of harmonic measure

    OpenAIRE

    Hofmann, Steve; Le, Phi

    2016-01-01

    We show that for a uniformly elliptic divergence form operator $L$, defined in an open set $\\Omega$ with Ahlfors-David regular boundary, BMO-solvability implies scale invariant quantitative absolute continuity (the weak-$A_\\infty$ property) of elliptic-harmonic measure with respect to surface measure on $\\partial \\Omega$. We do not impose any connectivity hypothesis, qualitative or quantitative; in particular, we do not assume the Harnack Chain condition, even within individual connected comp...

  4. Electroweak Absolute, Meta-, and Thermal Stability in Neutrino Mass Models

    CERN Document Server

    Lindner, Manfred; Radovčić, Branimir

    2015-01-01

    We analyze the stability of the electroweak vacuum in neutrino mass models containing right handed neutrinos or fermionic isotriplets. In addition to considering absolute stability, we place limits on the Yukawa couplings of new fermions based on metastability and thermal stability in the early Universe. Our results reveal that the upper limits on the neutrino Yukawa couplings can change significantly when the top quark mass is allowed to vary within the experimental range of uncertainty in its determination.

  5. Electroweak absolute, meta-, and thermal stability in neutrino mass models

    Science.gov (United States)

    Lindner, Manfred; Patel, Hiren H.; Radovčić, Branimir

    2016-04-01

    We analyze the stability of the electroweak vacuum in neutrino mass models containing right-handed neutrinos or fermionic isotriplets. In addition to considering absolute stability, we place limits on the Yukawa couplings of new fermions based on metastability and thermal stability in the early Universe. Our results reveal that the upper limits on the neutrino Yukawa couplings can change significantly when the top quark mass is allowed to vary within the experimental range of uncertainty in its determination.

  6. Absolute Pitch: Effects of Timbre on Note-Naming Ability

    OpenAIRE

    Patrícia Vanzella; E Glenn Schellenberg

    2010-01-01

    BACKGROUND: Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP pos...

  7. The Unity of Chemistry and Physics: Absolute Reaction Rate Theory

    OpenAIRE

    Hinne Hettema

    2012-01-01

    Henry Eyring's absolute rate theory explains the size of chemical reaction rate constants in terms of thermodynamics, statistical mechanics, and quantum chemistry. In addition it uses a number of unique concepts such as the 'transition state'. A key feature of the theory is that the explanation it provides relies on the comparison of reaction rate constant expressions derived from these individual theories. In this paper, the example is used to develop a naturalized notion of reduction and th...

  8. Measurement of the absolute branching fraction of the Ds+- meson

    CERN Document Server

    Abe, K; Dragic, J; Fujii, H; Gershon, T; Haba, J; Hazumi, M; Higuchi, T; Igarashi, Y; Itoh, R; Iwasaki, Y; Katayama, N; Kichimi, H; Krokovnyi, P P; Limosani, A; Nakamura, I; Nakao, M; Nakazawa, H; Nishida, S; Nozaki, T; Ozaki, H; Ronga, F J; Saitoh, S; Sakai, Y; Stamen, R; Sumisawa, K; Suzuki, S Y; Tajima, O; Takasaki, F; Tamai, K; Tanaka, M; Trabelsi, K; Tsuboyama, T; Tsukamoto, T; Uehara, S; Unno, Y; Uno, S; Ushiroda, Y; Yamauchi, M; Zhang, J; Hoshi, Y; Neichi, K; Aihara, H; Hastings, N C; Ishikawa, A; Itoh, K; Iwasaki, M; Kakuno, H; Kusaka, A; Nakahama, Y; Tanabe, K; Anipko, D; Arinstein, K; Aulchenko, V; Bedny, I; Bondar, A; Eidelman, S; Epifanov, D A; Gabyshev, N; Kuzmin, A; Poluektov, A; Root, N; Shwartz, B; Sidorov, V; Usov, Yu; Zhilich, V; Aoki, K; Enari, Y; Hara, K; Hayasaka, K; Hokuue, T; Iijima, T; Ikado, K; Inami, K; Kishimoto, N; Kozakai, Y; Kubota, T; Miyazaki, Y; Ohshima, T; Okabe, T; Sato, N; Senyo, K; Yoshino, S; Arakawa, T; Kawasaki, T; Miyata, H; Tamura, N; Watanabe, M; Asano, Y; Aso, T; Aushev, T; Bay, A; Hinz, L; Jacoby, C; Schietinger, T; Schneider, O; Villa, S; Wicht, J; Zürcher, D; Aziz, T; Banerjee, S; Gokhroo, G; Majumder, G; Bahinipati, S; Drutskoy, A; Goldenzweig, P; Kinoshita, K; Kulasiri, R; Sayeed, K; Schwartz, A J; Somov, A; Bakich, A M; Cole, S; McOnie, S; Parslow, N; Peak, L S; Stöck, H; Varvell, K E; Yabsley, B D; Balagura, V; Chistov, R; Danilov, M; Liventsev, D; Medvedeva, T; Mizuk, R; Pakhlov, P; Pakhlova, G; Tikhomirov, I; Uglov, T; Tian, Y BanX C; Barberio, E; Dalseno, J; Dowd, R; Moloney, G R; Sevior, M E; Taylor, G N; Tse, Y F; Urquijo, P; Barbero, M; Browder, T E; Guler, H; Jones, M; Li, J; Nishimura, K; Olsen, S L; Peters, M; Rorie, J; Sahoo, H; Uchida, K; Varner, G; Belous, K S; Shapkin, M; Sokolov, A; Bitenc, U; Bizjak, I; Fratina, S; Gorisek, A; Pestotnik, R; Staric, M; Zupanc, A; Blyth, S; Chen, A; Chen, W T; Go, A; Hou, S; Kuo, C C; Bozek, A; Kapusta, P; Lesiak, T; Matyja, A; Natkaniec, Z; Ostrowicz, W; Palka, H; Rózanska, M; Wiechczynski, J; Bracko, M; Korpar S; Brodzicka, J; Chang, M C; Kikuchi, N; Mikami, Y; Nagamine, T; Schonmeier, P; Yamaguchi, A; Yamamoto, H; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y B; Lee, Y J; Lin, C Y; Lin, S W; Shen, Y T; Tsai, Y T; Ueno, K; Wang, C C; Wang, M Z; Wu, C H; Cheon, B G; Choi, J H; Ha, H; Kang, J S; Won, E; Choi, S K; Choi, Y; Choi, Y K; Kim, H O; Kim, J H; Park, C W; Park, K S; Chuvikov, A; Garmash, A; Marlow, D; Ziegler, T; Dash, M; Mohapatra, D; Piilonen, L E; Yusa, Y; Fujikawa, M; Hayashii, H; Imoto, A; Kataoka, S U; Miyabayashi, K; Noguchi, S; Krizan, P; Golob, B; Seidl, R; Grosse-Perdekamp, M; Hara, T; Heffernan, D; Miyake, H; Hasegawa, Y; Satoyama, N; Takada, N; Nitoh, O; Hoshina, K; Ishino, H; Khan, H R; Kibayashi, A; Mori, T; Ono, S; Watanabe, Y; Iwabuchi, M; Kim, Y J; Liu, Y; Sarangi, T R; Uchida, Y; Kang, J H; Kim, T H; Kwon, Y J; Kurihara, E; Kawai, H; Park, H; Kim, H J; Kim, S K; Lee, J; Lee, S E; Yang He Young; Kumar, R; Singh, J B; Soni, N; Lange, J S; Leder, G; MacNaughton, J; Mandl, F; Mitaroff, W A; Pernicka, M; Schwanda, C; Widhalm, L; Matsumoto, T; Nakagawa, T; Seki, T; Sumiyoshi, T; Yamamoto, S; Müller, J; Murakami, A; Sugiyama, A; Suzuki, S; Nagasaka, Y; Nakano, E; Sakaue, H; Teramoto, Y; Ogawa, A; Shibuya, H; Ogawa, S; Okuno, S; Sakamoto, H; Wang, C H; Schümann, J; Stanic, S; Xie, Q L; Yuan, Y; Zang, S L; Zhang, C C; Yamashita, Y; Zhang, L M; Zhang, Z P

    2006-01-01

    The Ds+- -> K+-K-+pi+- absolute branching fraction is measured using e+e- -> Ds*+- Ds1-+(2536) events collected by the Belle detector at the KEKB e+e- asymmetric energy collider. Using the ratio of yields when either the Ds1 or Ds* is fully reconstructed, we find Br(Ds+- -> K+-K-+pi+-)= (4.0+-0.4(stat)+-0.4(sys))%.

  9. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  10. The Intonation of absolute questions of Brazilian Portuguese

    OpenAIRE

    Cantero Serena, Francisco José; Font Rotchés, Dolors

    2013-01-01

    In this paper we describe three melodic patterns of absolute interrogatives from a phonetic point of view, obtained from a corpus in Goiás (Brazil). The patterns are: a) Rising Final Inflection (30% to 52%), b) Rising-Falling Final Inflection, c) High Nucleus Final Inflection. These patterns have been established from the acoustic analysis and standardisation of 55 questions and from the verification of their validity in a perception test. We compared them with interrogative patterns obtained...

  11. Predictive visual tracking based on least absolute deviation estimation

    Institute of Scientific and Technical Information of China (English)

    Rongtai Cai; Yanjie Wang

    2008-01-01

    To cope with the occlusion and intersection between targets and the environment, location prediction is employed in the visual tracking system. Target trace is fitted by sliding subsection polynomials based on least absolute deviation (LAD) estimation, and the future location of target is predicted with the fitted trace. Experiment results show that the proposed location prediction algorithm based on LAD estimation has significant robustness advantages over least square (LS) estimation, and it is more effective than LS-based methods in visual tracking.

  12. Son preference in Indian families: absolute versus relative wealth effects.

    Science.gov (United States)

    Gaudin, Sylvestre

    2011-02-01

    The desire for male children is prevalent in India, where son preference has been shown to affect fertility behavior and intrahousehold allocation of resources. Economic theory predicts less gender discrimination in wealthier households, but demographers and sociologists have argued that wealth can exacerbate bias in the Indian context. I argue that these apparently conflicting theories can be reconciled and simultaneously tested if one considers that they are based on two different notions of wealth: one related to resource constraints (absolute wealth), and the other to notions of local status (relative wealth). Using cross-sectional data from the 1998-1999 and 2005-2006 National Family and Health Surveys, I construct measures of absolute and relative wealth by using principal components analysis. A series of statistical models of son preference is estimated by using multilevel methods. Results consistently show that higher absolute wealth is strongly associated with lower son preference, and the effect is 20%-40% stronger when the household's community-specific wealth score is included in the regression. Coefficients on relative wealth are positive and significant although lower in magnitude. Results are robust to using different samples, alternative groupings of households in local areas, different estimation methods, and alternative dependent variables.

  13. Bio-Inspired Stretchable Absolute Pressure Sensor Network.

    Science.gov (United States)

    Guo, Yue; Li, Yu-Hung; Guo, Zhiqiang; Kim, Kyunglok; Chang, Fu-Kuo; Wang, Shan X

    2016-01-01

    A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4'' wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles. PMID:26729134

  14. Bio-Inspired Stretchable Absolute Pressure Sensor Network

    Directory of Open Access Journals (Sweden)

    Yue Guo

    2016-01-01

    Full Text Available A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4’’ wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles.

  15. Absolute orientations from EBSD measurements - as easy as it seems?

    Science.gov (United States)

    Kilian, Rüdiger; Bestmann, Michel; Heilbronner, Renée

    2016-04-01

    In structural geology, some problems can be addressed by inspecting the crystal orientation of grains in a rock. Deriving shear senses, kinematics of flow, information on deformation processes and recrystallization are some examples. Usually, oriented samples are taken in the field and, if inspected in an universal stage, the researcher has full control over the procedure and can make sure that the derived orientation is related to our geographic reference frame - that it is an absolute orientation. Nowadays, usage of electron backscatter diffraction (EBSD) has greatly improved the information in the derived data (fully crystal orientations, mappings, etc…), and the speed of data acquisition. However, this comes to the price of having to rely on the vendor supplied software and machine setup. Recent benchmarks and comparison of reference data revealed that for various EBSD setups around the world, the orientation data defaults to the wrong absolute orientation. The absolute orientation is not correctly derived - it commonly suffer a 180 degree rotation around the normal of the sample surface. In this contribution we will discuss the implications of such erroneous measurements and what kind of interpretations derived by orientation and texture data will be affected.

  16. Absolute photoionization cross-section of the propargyl radical

    Energy Technology Data Exchange (ETDEWEB)

    Savee, John D.; Welz, Oliver; Taatjes, Craig A.; Osborn, David L. [Sandia National Laboratories, Combustion Research Facility, Livermore, California 94551 (United States); Soorkia, Satchin [Institut des Sciences Moleculaires d' Orsay, Universite Paris-Sud 11, Orsay (France); Selby, Talitha M. [Department of Chemistry, University of Wisconsin, Washington County Campus, West Bend, Wisconsin 53095 (United States)

    2012-04-07

    Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

  17. Absolute surface reconstruction by slope metrology and photogrammetry

    Science.gov (United States)

    Dong, Yue

    Developing the manufacture of aspheric and freeform optical elements requires an advanced metrology method which is capable of inspecting these elements with arbitrary freeform surfaces. In this dissertation, a new surface measurement scheme is investigated for such a purpose, which is to measure the absolute surface shape of an object under test through its surface slope information obtained by photogrammetric measurement. A laser beam propagating toward the object reflects on its surface while the vectors of the incident and reflected beams are evaluated from the four spots they leave on the two parallel transparent windows in front of the object. The spots' spatial coordinates are determined by photogrammetry. With the knowledge of the incident and reflected beam vectors, the local slope information of the object surface is obtained through vector calculus and finally yields the absolute object surface profile by a reconstruction algorithm. An experimental setup is designed and the proposed measuring principle is experimentally demonstrated by measuring the absolute surface shape of a spherical mirror. The measurement uncertainty is analyzed, and efforts for improvement are made accordingly. In particular, structured windows are designed and fabricated to generate uniform scattering spots left by the transmitted laser beams. Calibration of the fringe reflection instrument, another typical surface slope measurement method, is also reported in the dissertation. Finally, a method for uncertainty analysis of a photogrammetry measurement system by optical simulation is investigated.

  18. The Absolute Magnitudes of Type Ia Supernovae in the Ultraviolet

    CERN Document Server

    Brown, Peter J; Milne, Peter; Bufano, Filomena; Ciardullo, Robin; Elias-Rosa, Nancy; Filippenko, Alexei V; Foley, Ryan J; Gehrels, Neil; Gronwall, Caryl; Hicken, Malcolm; Holland, Stephen T; Hoversten, Erik A; Immler, Stefan; Kirshner, Robert P; Li, Weidong; Mazzali, Paolo; Phillips, Mark M; Pritchard, Tyler; Still, Martin; Turatto, Massimo; Berk, Daniel Vanden

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby(redshift z = 0.004--0.027) Type Ia supernovae (SNe~Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way (MW) extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1_rc covering ~2600-3300 A after removing optical light, and u ~3000--4000 A) compared to a mid-UV filter (uvm2 ~2000-2400 A). The uvw1_rc-b colors show a scatter of ~0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2-uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with ...

  19. On the absolute value of the air-fluorescence yield

    CERN Document Server

    Rosado, J; Arqueros, F

    2014-01-01

    The absolute value of the air-fluorescence yield is a key parameter for the energy reconstruction of extensive air showers registered by fluorescence telescopes. In previous publications, we reported a detailed Monte Carlo simulation of the air-fluorescence generation that allowed the theoretical evaluation of this parameter. This simulation has been upgraded in the present work. As a result, we determined an updated absolute value of the fluorescence yield of 7.9+-2.0 ph/MeV for the band at 337 nm in dry air at 800 hPa and 293 K, in agreement with experimental values. We have also performed a critical analysis of available absolute measurements of the fluorescence yield with the assistance of our simulation. Corrections have been applied to some measurements to account for a bias in the evaluation of the energy deposition. Possible effects of other experimental aspects have also been discussed. From this analysis, we determined an average fluorescence yield of 7.04+-0.24 ph/MeV at the above conditions.

  20. Bio-Inspired Stretchable Absolute Pressure Sensor Network.

    Science.gov (United States)

    Guo, Yue; Li, Yu-Hung; Guo, Zhiqiang; Kim, Kyunglok; Chang, Fu-Kuo; Wang, Shan X

    2016-01-02

    A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4'' wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles.

  1. Son preference in Indian families: absolute versus relative wealth effects.

    Science.gov (United States)

    Gaudin, Sylvestre

    2011-02-01

    The desire for male children is prevalent in India, where son preference has been shown to affect fertility behavior and intrahousehold allocation of resources. Economic theory predicts less gender discrimination in wealthier households, but demographers and sociologists have argued that wealth can exacerbate bias in the Indian context. I argue that these apparently conflicting theories can be reconciled and simultaneously tested if one considers that they are based on two different notions of wealth: one related to resource constraints (absolute wealth), and the other to notions of local status (relative wealth). Using cross-sectional data from the 1998-1999 and 2005-2006 National Family and Health Surveys, I construct measures of absolute and relative wealth by using principal components analysis. A series of statistical models of son preference is estimated by using multilevel methods. Results consistently show that higher absolute wealth is strongly associated with lower son preference, and the effect is 20%-40% stronger when the household's community-specific wealth score is included in the regression. Coefficients on relative wealth are positive and significant although lower in magnitude. Results are robust to using different samples, alternative groupings of households in local areas, different estimation methods, and alternative dependent variables. PMID:21302027

  2. Use of intensity quotients and differences in absolute structure refinement

    International Nuclear Information System (INIS)

    Differences and quotients can be defined using Friedel pairs of reflections and applied in refinement to enable absolute structure to be determined precisely even for light atom crystal structures. Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement

  3. The new Absolute Quantum Gravimeter (AQG): first results and perspectives

    Science.gov (United States)

    Bonvalot, Sylvain; Le Moigne, Nicolas; Merlet, Sebastien; Desruelle, Bruno; Lautier-Gaud, Jean; Menoret, Vincent; Vermeulen, Pierre

    2016-04-01

    Cold atom gravimetry represents one of the most innovative evolution in gravity instrumentation since the last 20 years. The concept of measuring the gravitational acceleration by dropping atoms and the development of the first instrumental devices during this last decade quickly revealed the promising perspectives of this new generation of gravity meters enabling accurate and absolute measurements of the Earth's gravity field for a wide range of applications (geophysics, geodesy, metrology, etc.). The Absolute Quantum Gravimeter (AQG) gravity meter, developed by MUQUANS (Talence, France - http://www.muquans.com/) with the support of RESIF, the French Seismologic and Geodetic Network (http://www.resif.fr/) belongs to this new generation of instruments. It also represents the first commercial device based on the utilization of advanced matter-wave interferometry techniques, which allow to characterize precisely the vertical acceleration experienced by a cloud of cold atoms. Recently, the first operational unit (AQG01) has been achieved as a compact transportable gravimeter with the aim of satisfying absolute gravity measurements in laboratory conditions under the following specifications: measurements the μGal level at a few Hz cycling frequency, sensitivity of 50μGal/√Hz, immunity to ground vibrations, easy and quickness of operation, automated continuous data acquisition for several months, etc. In order to evaluate the current performances of the AQG01, several experiments are carried out in collaboration between RESIF user's teams and the MUQUANS manufacturer on different reference gravity sites and laboratories in France. These measurements performed in indoor conditions including simultaneous observations with classical reference gravity instruments (corner-cube absolute gravity meters, relative superconducting meters) as well with the Cold Atom Gravity meter (CAG) developed by LNE-SYRTE, lead to a first objective characterization of the performances of

  4. 菲律宾海西北部岩芯记录的125 ka以来的地磁场强度及其影响因素%Relative paleointensity recorded in the core of northwestern Philippine Sea for the last 125 ka and its influencing factors

    Institute of Scientific and Technical Information of China (English)

    葛淑兰; L(Φ)VLIE Reidar; 石学法; 方习生; 陈志华; 吴永华

    2013-01-01

    Relative paleointensity from sediments provides constraints for geomagnetic field modeling and also the age information of the deposit. The relative paleointensity in a core of the northwestern Philippine Sea was reported and its possible influencing factors including rock magnetic and sedimentological property are examined. Except for the rotation of declination in the brown clay at lower part of the core, both directions of anisotropy of magnetic susceptibility and of geomagnetic field indicate original sedimentary nature. The magnetically uniform sediment conforms to the requirement for relative paleointensity study and the correlation of relative paleointensity proxies NRM/ARM and NRM/κ with PISO1500 and SINT800 produce depth-age tie points. The sparse oxygen isotopes on paleointensity chronology in this core agree with global stack LR04, confirming the correlation of paleointensity. NRM/κ is usually lower than NRM/ ARM, and the latter has no correlation with ARM and ARM/κ and also no astronomical period, but the former is correlated with ARM/κ and κ and a period of 13 - 12 ka by spectrum and coherence analysis. Therefore NRM/ARM is regarded to shun off imprint of climate. Further investigations between the intensity difference and its affecting elements find that difference between NRM/ARM and NRM/κ covaries with super-paramagnetic content and magnetic size variation, and the latter contributing 90% of the difference. Other elements like carbonate percentage and mineralogy change are not responsible for the difference. How to adjust the effect of magnetic size on paleointensity estimation is the focus of further work.%沉积物记录的地磁场强度首先提供了模拟地磁场演化的数据约束,其次提供了沉积物的年龄信息.本文报道了菲律宾海西北部岩芯记录的地磁场相对强度,并结合岩石磁学和沉积学性质探讨了影响强度的各个因素.除底部红粘土层的局部磁偏角偏转可能揭示了沉积

  5. Absolute versus relative ascertainment of pedophilia in men.

    Science.gov (United States)

    Blanchard, Ray; Kuban, Michael E; Blak, Thomas; Cantor, James M; Klassen, Philip E; Dickey, Robert

    2009-12-01

    There are at least two different criteria for assessing pedophilia in men: absolute ascertainment (their sexual interest in children is intense) and relative ascertainment (their sexual interest in children is greater than their interest in adults). The American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, 3rd edition (DSM-III) used relative ascertainment in its diagnostic criteria for pedophilia; this was abandoned and replaced by absolute ascertainment in the DSM-III-R and all subsequent editions. The present study was conducted to demonstrate the continuing need for relative ascertainment, particularly in the laboratory assessment of pedophilia. A total of 402 heterosexual men were selected from a database of patients referred to a specialty clinic. These had undergone phallometric testing, a psychophysiological procedure in which their penile blood volume was monitored while they were presented with a standardized set of laboratory stimuli depicting male and female children, pubescents, and adults.The 130 men selected for the Teleiophilic Profile group responded substantially to prepubescent girls but even more to adult women; the 272 men selected for the Pedophilic Profile group responded weakly to prepubescent girls but even less to adult women. In terms of absolute magnitude, every patient in the Pedophilic Profile group had a lesser penile response to prepubescent girls than every patient in the Teleiophilic Profile group. Nevertheless, the Pedophilic Profile group had a significantly greater number of known sexual offenses against prepubescent girls, indicating that they contained a higher proportion of true pedophiles. These results dramatically demonstrate the utility-or perhaps necessity-of relative ascertainment in the laboratory assessment of erotic age-preference.

  6. Automated absolute activation analysis with californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg /sup 252/Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from /sup 17/O. Detection sensitivities of < or = 400 ppB for natural uranium and 8 ppB (< or = 0.5 (nCi/g)) for /sup 239/Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level.

  7. Absolute versus relative ascertainment of pedophilia in men.

    Science.gov (United States)

    Blanchard, Ray; Kuban, Michael E; Blak, Thomas; Cantor, James M; Klassen, Philip E; Dickey, Robert

    2009-12-01

    There are at least two different criteria for assessing pedophilia in men: absolute ascertainment (their sexual interest in children is intense) and relative ascertainment (their sexual interest in children is greater than their interest in adults). The American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, 3rd edition (DSM-III) used relative ascertainment in its diagnostic criteria for pedophilia; this was abandoned and replaced by absolute ascertainment in the DSM-III-R and all subsequent editions. The present study was conducted to demonstrate the continuing need for relative ascertainment, particularly in the laboratory assessment of pedophilia. A total of 402 heterosexual men were selected from a database of patients referred to a specialty clinic. These had undergone phallometric testing, a psychophysiological procedure in which their penile blood volume was monitored while they were presented with a standardized set of laboratory stimuli depicting male and female children, pubescents, and adults.The 130 men selected for the Teleiophilic Profile group responded substantially to prepubescent girls but even more to adult women; the 272 men selected for the Pedophilic Profile group responded weakly to prepubescent girls but even less to adult women. In terms of absolute magnitude, every patient in the Pedophilic Profile group had a lesser penile response to prepubescent girls than every patient in the Teleiophilic Profile group. Nevertheless, the Pedophilic Profile group had a significantly greater number of known sexual offenses against prepubescent girls, indicating that they contained a higher proportion of true pedophiles. These results dramatically demonstrate the utility-or perhaps necessity-of relative ascertainment in the laboratory assessment of erotic age-preference. PMID:19901237

  8. Carbon clusters for absolute mass measurements at ISOLTRAP

    CERN Document Server

    Blaum, K; Herfurth, F; Kellerbauer, A G; Kluge, H J; Kuckein, M; Sauvan, E; Scheidenberger, C; Schweikhard, L

    2002-01-01

    The cyclotron frequencies of singly charged carbon clusters C/sub n //sup +/ (n >or= 2) were measured with the Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN. The present limit of mass accuracy delta m/m = 1.2.10/sup -8/ and the extent of the mass- dependent systematic shift ( delta m/m)/sub sys/ = 1.7(0.6).10/sup -10//u.(m - m/sub ref/) of the setup were investigated for the first time. In addition, absolute mass measurements by use of pure clusters of the most abundant carbon isotope /sup 12/C are now possible at ISOLTRAP. (15 refs).

  9. On Absolute Measurements of β-Emitting Radionuclides

    International Nuclear Information System (INIS)

    4 π GM detectors are described and some of their characteristics presented. The absence of spurious pulses is shown by the measurement of the rate of arrival of intervals between pulses. Some problems related to the foil absorption and source absorption are considered using Sr90 and Y90. Aiming at correcting the counting losses in the foil and in a certain extent also the source absorption an experimental method which uses paired sources is presented. The preparation of standards of Bi210 (RaE) is described. A note is presented on the problem of foil absorption losses in scintillation absolute counting. (author)

  10. Strategy for the absolute neutron emission measurement on ITER.

    Science.gov (United States)

    Sasao, M; Bertalot, L; Ishikawa, M; Popovichev, S

    2010-10-01

    Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10(10) n/s (neutron/second) for DT and 10(8) n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

  11. Absolute standardization of 106Ru by anti-coincidence method

    International Nuclear Information System (INIS)

    The system of absolute standardization activity of radionuclide by anti-coincidence counting and live-time techniques was implemented at LNMRI in 2008 to reduce the impacts of some influence factors in the determination of the activity with coincidence counting technique used for decades in the lab, for example, the measurement time. With the anti-coincidence system, the variety of radionuclides that can be calibrated by LNMRI was increased, in relation to the type of decay. The objective of this work is the standardization of 106Ru by the method of counting anti-coincidence and estimate its measurement uncertainties. (author)

  12. Testing and evaluation of thermal cameras for absolute temperature measurement

    Science.gov (United States)

    Chrzanowski, Krzysztof; Fischer, Joachim; Matyszkiel, Robert

    2000-09-01

    The accuracy of temperature measurement is the most important criterion for the evaluation of thermal cameras used in applications requiring absolute temperature measurement. All the main international metrological organizations currently propose a parameter called uncertainty as a measure of measurement accuracy. We propose a set of parameters for the characterization of thermal measurement cameras. It is shown that if these parameters are known, then it is possible to determine the uncertainty of temperature measurement due to only the internal errors of these cameras. Values of this uncertainty can be used as an objective criterion for comparisons of different thermal measurement cameras.

  13. System Design of the ATLAS Absolute Luminosity Monitor

    CERN Document Server

    Anghinolfi, Francis; Franz, Sebastien; Iwanski, W; Lundberg, B; PH-EP

    2007-01-01

    The ATLAS absolute luminosity monitor is composed of 8 roman pots symmetrically located in the LHC tunnel. Each pot contains 23 multi anode photomultiplier tubes, and each one of those is fitted with a front-end assembly called PMF. A PMF provides the high voltage biasing of the tube, the frontend readout chip and the readout logic in a very compact arrangement. The 25 PMFs contained in one roman pot are connected to a motherboard used as an interface to the backend electronics. The system allows to configure the front-end electronics from the ATLAS detector control system and to transmit the luminosity data over Slink.

  14. Analysis of Absolute Stability for Time-delay Teleoperation Systems

    Institute of Scientific and Technical Information of China (English)

    Qi-Wen Deng; Qing Wei; Ze-Xiang Li

    2007-01-01

    In this paper, a new bilateral control algorithm based on absolute stability theory is put forward, which aims at the time-delay teleoperation system with force feedback from the slave directly. In the new control algorithm, the delay-dependent stability,instead of delay-independent stability, is taken as the aim of control design. It improves the transparency of the system at the price of unnecessary stability. With this algorithm, the time-delay teleoperation systems have good transparency and stability. A simulation system is established to verify the effect of this algorithm.

  15. Strategy for the absolute neutron emission measurement on ITER

    International Nuclear Information System (INIS)

    Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 1010 n/s (neutron/second) for DT and 108 n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

  16. Measuring Postglacial Rebound with GPS and Absolute Gravity

    Science.gov (United States)

    Larson, Kristine M.; vanDam, Tonie

    2000-01-01

    We compare vertical rates of deformation derived from continuous Global Positioning System (GPS) observations and episodic measurements of absolute gravity. We concentrate on four sites in a region of North America experiencing postglacial rebound. The rates of uplift from gravity and GPS agree within one standard deviation for all sites. The GPS vertical deformation rates are significantly more precise than the gravity rates, primarily because of the denser temporal spacing provided by continuous GPS tracking. We conclude that continuous GPS observations are more cost efficient and provide more precise estimates of vertical deformation rates than campaign style gravity observations where systematic errors are difficult to quantify.

  17. Absolute Measurement Fiber-optic Sensors in Large Structural Monitoring

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The security of civil engineering is an important task due to the economic, social and environmental significance. Compared with conventional sensors, the optical fiber sensors have their unique characteristics.Being durable, stable and insensitive to external perturbations,they are particular interesting for the long-term monitoring of civil structures.Focus is on absolute measurement optical fiber sensors, which are emerging from the monitoring large structural, including SOFO system, F-P optical fiber sensors, and fiber Bragg grating sensors. The principle, characteristic and application of these three kinds of optical fiber sensors are described together with their future prospects.

  18. Stability of array spectroradiometers and their suitability for absolute calibrations

    Science.gov (United States)

    Nevas, Saulius; Teuber, Annette; Sperling, Armin; Lindemann, Matthias

    2012-04-01

    An investigation of the short- and long-term stability of various low-end and high-end array spectroradiometers is presented. Potentially weak points of array spectroradiometers with respect to their suitability for absolute calibrations are pointed out. The influence of ambient conditions on relevant instrumental characteristics and their temporal stability is discussed. It is shown that the temporal stability of some instruments can be significantly affected by high ambient humidity. Most important ambient temperature effects on instrument properties are also discussed.

  19. Predicting accurate absolute binding energies in aqueous solution

    DEFF Research Database (Denmark)

    Jensen, Jan Halborg

    2015-01-01

    Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic. In this paper I summarize some of the many factors that could easily contribute 1-3 kcal......-represented by continuum models. While I focus on binding free energies in aqueous solution the approach also applies (with minor adjustments) to any free energy difference such as conformational or reaction free energy differences or activation free energies in any solvent....

  20. Electromagnetic Hydrophone with Tomographic System for Absolute Velocity Field Mapping

    CERN Document Server

    Grasland-Mongrain, Pol; Mari, Jean-Martial; Chapelon, Jean-Yves; Lafon, Cyril; 10.1063/1.4726178

    2012-01-01

    The velocity and pressure of an ultrasonic wave can be measured by an electromagnetic hydrophone made of a thin wire and a magnet. The ultrasonic wave vibrates the wire inside a magnetic field, inducing an electrical current. Previous articles reported poor spatial resolution of comparable hydrophones along the axis of the wire. In this study, submillimetric spatial resolution has been achieved by using a tomographic method. Moreover, a physical model is presented for obtaining absolute measurements. A pressure differential of 8% has been found between piezoelectric and electromagnetic hydrophone measurements. These characteristics show this technique as an alternative to standard hydrophones.

  1. An associated particle technique for absolute neutron counting efficiency determination

    International Nuclear Information System (INIS)

    The 7Li(p,n)7Be reaction has been used to produce neutrons with energies ranging from 8 to 13 MeV in order to measure the absolute neutron counting efficiency of a large NE213 scintillator by the associated particle method. Recoil 7Be nuclei were detected with a ΔE(gas)-E (solid) telescope in coincidence with neutrons. The method is suitable for neutron energies greater than 1.2MeV and could be applied to establish the neutron efficiency response of any detector

  2. Synthesis and Absolute Configuration of the Diynediol from Psathyrella scobinacea

    Institute of Scientific and Technical Information of China (English)

    WU Jianzhong; WU Yikang; JIAN Yajun; ZHANG Yihua

    2009-01-01

    All the four isomers of Scobidiynediol (hepta-4,6-diyne-2,3-diol), a natural product isolated from white-rot fungus Psathyrella scobinacea, were synthesized using either (R)-or(S)-lactate as the source of chirality. The rela-tive configurations of the diols were established by NOE experiments performed on the cyclic acetonides. The rela-tive as well as absolute configurations of the natural Scobidiynediol was assigned as (2S,3S) through comparison of the optical rotation and 1H NMR data.

  3. Absolute Measurement of Quantum-Limited Interferometric Displacements

    CERN Document Server

    Thiel, Valérian; Treps, Nicolas; Roslund, Jonathan

    2016-01-01

    A methodology is introduced that enables an absolute, quantum-limited measurement of sub-wavelength interferometric displacements. The technique utilizes a high-frequency optical path modulation within an interferometer operated in a homodyne configuration. All of the information necessary to fully characterize the resultant path displacement is contained within the relative strengths of the various harmonics of the phase modulation. The method, which is straightforward and readily implementable, allows a direct measurement of the theoretical Cram\\'er-Rao limit of detection without any assumptions on the nature of the light source.

  4. The absolute threshold photodetachment cross-section of Al-

    International Nuclear Information System (INIS)

    The total absolute photodetachment cross-section of the aluminum anion, Al-, is calculated in the threshold spectral region for photons of wave numbers 3400 - 3650cm-1 using the zero-core contribution (ZCC) model. A computer least-squares curve fit is used to test the validity of the Wigner threshold law and the deviation from recent experimental measurements of the relative photodetachment cross-section. It is found that the best agreements is achieved with a smaller core radius rο=1.60 Angstrom rather than the value of 1.82 Angstrom used earlier. (authors). 22 refs., 5 figs., 1 tab

  5. ABSOLUTELY E-PURE MODULES AND E-PURE SPLIT MODULES

    Institute of Scientific and Technical Information of China (English)

    Yan Hangyu

    2011-01-01

    We first introduce the concepts of absolutely E-pure modules and Epure split modules. Then, we characterize the IF rings in terms of absolutely E-pure modules. The E-pure split modules are also characterized.

  6. Structure and Absolute Configuration of Nyasol and Hinokiresinol via Synthesis and Vibrational Circular Dichroism Spectroscopy

    DEFF Research Database (Denmark)

    Lassen, Peter Rygaard

    2005-01-01

    The absolute configuration of the norlignan (+)-nyasol was determined to be S by comparison of the experimental vibrational circular dichroism data with first-principle calculations taking into account the eight lowest energy conformations. The established absolute configuration of (+)-nyasol...

  7. An immune response study of oakmoss absolute and its constituents atranol and chloroatranol

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte Menné; Nielsen, Morten Milek; Gimenéz-Arnau, Elena;

    2014-01-01

    BACKGROUND: Atranol and chloroatranol are the main allergens of oakmoss absolute. However, the immune responses induced by these substances are poorly characterized. OBJECTIVES: To characterize immune responses induced by atranol, chloroatranol and oakmoss absolute in mice. METHODS: Mice were sen...

  8. Usage Tests of Oak Moss Absolutes Containing High and Low Levels of Atranol and Chloroatranol.

    OpenAIRE

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-01-01

    Atranol and chloroatranol are strong contact allergens in oak moss absolute, a lichen extract used in perfumery. Fifteen subjects with contact allergy to oak moss absolute underwent a repeated open application test (ROAT) using solutions of an untreated oak moss absolute (sample A) and an oak moss absolute with reduced content of atranol and chloroatranol (sample B). All subjects were in addition patch-tested with serial dilutions of samples A and B. Statistically significantly more subjects ...

  9. Simulation of absolute amplitudes of ultrasound signals using equivalent circuits.

    Science.gov (United States)

    Johansson, Jonny; Martinsson, Pär-Erik; Delsing, Jerker

    2007-10-01

    Equivalent circuits for piezoelectric devices and ultrasonic transmission media can be used to cosimulate electronics and ultrasound parts in simulators originally intended for electronics. To achieve efficient system-level optimization, it is important to simulate correct, absolute amplitude of the ultrasound signal in the system, as this determines the requirements on the electronics regarding dynamic range, circuit noise, and power consumption. This paper presents methods to achieve correct, absolute amplitude of an ultrasound signal in a simulation of a pulse-echo system using equivalent circuits. This is achieved by taking into consideration loss due to diffraction and the effect of the cable that connects the electronics and the piezoelectric transducer. The conductive loss in the transmission line that models the propagation media of the ultrasound pulse is used to model the loss due to diffraction. Results show that the simulated amplitude of the echo follows measured values well in both near and far fields, with an offset of about 10%. The use of a coaxial cable introduces inductance and capacitance that affect the amplitude of a received echo. Amplitude variations of 60% were observed when the cable length was varied between 0.07 m and 2.3 m, with simulations predicting similar variations. The high precision in the achieved results show that electronic design and system optimization can rely on system simulations alone. This will simplify the development of integrated electronics aimed at ultrasound systems. PMID:18019234

  10. Absolute calibration of a multilayer-based XUV diagnostic

    CERN Document Server

    Stuik, R; Tümmler, J; Bijkerk, F

    2002-01-01

    A portable, universal narrowband XUV diagnostic suitable for calibration of various XUV light sources, was built, tested and fully calibrated. The diagnostic allows measurement of the absolute XUV energy and average power in two selected wavelength bands, at 11.4 and 13.4 nm. In addition, the pulse-to-pulse and long-term XUV stability of the source can be assessed, as well as the contamination of multilayer XUV optics exposed to the source. This paper describes the full calibration procedure: all optical elements were calibrated at the wavelength of operation by Physikalisch-Technische Bundesanstalt at the storage ring Bessy II, a full analysis of geometrical factors was done, and the influence of the spectral emissivity of the source on the calibration was analyzed in detail. The calibration was performed both for the centroid wavelength as for the full bandwidth of the diagnostic. The total uncertainty in the absolute calibration allowed measurement of source characteristics with an uncertainty of less than...

  11. Pleiades Absolute Calibration : Inflight Calibration Sites and Methodology

    Science.gov (United States)

    Lachérade, S.; Fourest, S.; Gamet, P.; Lebègue, L.

    2012-07-01

    In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station) and Oceans (Calibration over molecular scattering) or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  12. Absolute configuration and antimicrobial activity of acylhomoserine lactones.

    Science.gov (United States)

    Pomini, Armando M; Marsaioli, Anita J

    2008-06-01

    (S)-N-Heptanoylhomoserine lactone is an uncommon acyl odd-chain natural product employed by many Gram-negative bacteria as a signaling substance in chemical communication mechanisms known as quorum sensing. The absolute configuration determination of the metabolite produced by the phytopathogen Pantoea ananatis Serrano is reported herein. As with all other substances of this class, the lactone moiety possesses S configuration, corroborating the hypothesis that it shares the same biosynthetic pathway as the (S)-N-hexanoylhomoserine lactone and also that some LuxI homologues can accept both hexanoyl- and heptanoyl-ACP as precursors. Evaluation of the antimicrobial activity of enantiomeric acylhomoserine lactones against three Gram-positive bacteria (Bacillus cereus, B. subtilis, and Staphylococcus aureus) revealed important features between absolute configuration and antimicrobial activity. The N-heptanoylhomoserine lactone was considerably less active than the 3-oxo derivatives. Surprisingly, non-natural (R)-N-(3-oxo-octanoyl)homoserine lactone was as active as the S enantiomer against B. cereus, while the synthetic racemic product was less active than either enantiomer. PMID:18465897

  13. Absolute Temperature Monitoring Using RF Radiometry in the MRI Scanner.

    Science.gov (United States)

    El-Sharkawy, Abdel-Monem M; Sotiriadis, Paul P; Bottomley, Paul A; Atalar, Ergin

    2006-11-01

    Temperature detection using microwave radiometry has proven value for noninvasively measuring the absolute temperature of tissues inside the body. However, current clinical radiometers operate in the gigahertz range, which limits their depth of penetration. We have designed and built a noninvasive radiometer which operates at radio frequencies (64 MHz) with ∼100-kHz bandwidth, using an external RF loop coil as a thermal detector. The core of the radiometer is an accurate impedance measurement and automatic matching circuit of 0.05 Ω accuracy to compensate for any load variations. The radiometer permits temperature measurements with accuracy of ±0.1°K, over a tested physiological range of 28° C-40° C in saline phantoms whose electric properties match those of tissue. Because 1.5 T magnetic resonance imaging (MRI) scanners also operate at 64 MHz, we demonstrate the feasibility of integrating our radiometer with an MRI scanner to monitor RF power deposition and temperature dosimetry, obtaining coarse, spatially resolved, absolute thermal maps in the physiological range. We conclude that RF radiometry offers promise as a direct, noninvasive method of monitoring tissue heating during MRI studies and thereby providing an independent means of verifying patient-safe operation. Other potential applications include titration of hyper- and hypo-therapies. PMID:18026562

  14. Use of intensity quotients and differences in absolute structure refinement.

    Science.gov (United States)

    Parsons, Simon; Flack, Howard D; Wagner, Trixie

    2013-06-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  15. High-precision absolute measurement of CEBAF beam mean energy

    International Nuclear Information System (INIS)

    The absolute measurement of the beam mean energy with an accuracy of one part in 104 or higher is an important demand of the CEBAF Hall A physics program. This accuracy may reduce the uncertainty in the d(e, e'p)p cross section δσ/σ to 1%. The need for such an accurately calibrated beam is not particular to CEBAF; at other electron facilities uncertainty in the incident energy has proven to be among the dominant sources of systematic error. The following methods for solving the problem were considered at both CEBAF and the Yerevan Physics Institute during 1990--1991: Backscattering of a plane electromagnetic wave by the relativistic electron beam. Calculations show that the intensity of the backscattered radiation in a bandwidth of 10-4 near the maximum frequency is about 1 photon per second at 4 GeV and 0.3 mA. Magnetic spectrometers performing as three- and four-magnet chicanes with appropriate detector systems. Such a system was used at SLAC for absolute measurement of the SLC beams energy, where a maximum accuracy of 5 x 10-4 was achieved. Calculations show that a similar accuracy can be achieved for the CEBAF beam in both proposed systems. Measurement of the vertical distribution of synchrotron radiation. Calculations indicate that precision of about 2.5 x 10-5 is achievable for CEBAF

  16. A Special Application of Absolute Value Techniques in Authentic Problem Solving

    Science.gov (United States)

    Stupel, Moshe

    2013-01-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value…

  17. Swarm Absolute Scalar Magnetometers first in-orbit results

    Science.gov (United States)

    Fratter, Isabelle; Léger, Jean-Michel; Bertrand, François; Jager, Thomas; Hulot, Gauthier; Brocco, Laura; Vigneron, Pierre

    2016-04-01

    The ESA Swarm mission will provide the best ever survey of the Earth's magnetic field and its temporal evolution. This will be achieved by a constellation of three identical satellites, launched together on the 22nd of November 2013. In order to observe the magnetic field thoroughly, each satellite carries two magnetometers: a Vector Field Magnetometer (VFM) coupled with a star tracker camera, to measure the direction of the magnetic field in space, and an Absolute Scalar Magnetometer (ASM), to measure its intensity. The ASM is the French contribution to the Swarm mission. This new generation instrument was designed by CEA-Leti and developed in close partnership with CNES, with scientific support from IPGP. Its operating principle is based on the atomic spectroscopy of the helium 4 metastable state. It makes use of the Zeeman's effect to transduce the magnetic field into a frequency, the signal being amplified by optical pumping. The primary role of the ASM is to provide absolute measurements of the magnetic field's strength at 1 Hz, for the in-flight calibration of the VFM. As the Swarm magnetic reference, the ASM scalar performance is crucial for the mission's success. Thanks to its innovative design, the ASM offers the best precision, resolution and absolute accuracy ever attained in space, with similar performance all along the orbit. In addition, thanks to an original architecture, the ASM implements on an experimental basis a capacity for providing simultaneously vector measurements at 1 Hz. This new feature makes it the first instrument capable of delivering both scalar and vector measurements simultaneously at the same point. Swarm offers a unique opportunity to validate the ASM vector data in orbit by comparison with the VFM's. Furthermore, the ASM can provide scalar data at a much higher sampling rate, when run in "burst" mode at 250 Hz, with a 100 Hz measurement bandwidth. An analysis of the spectral content of the magnetic field above 1 Hz becomes thus

  18. Landsat-7 ETM+ radiometric stability and absolute calibration

    Science.gov (United States)

    Markham, B.L.; Barker, J.L.; Barsi, J.A.; Kaita, E.; Thome, K.J.; Helder, D.L.; Palluconi, Frank Don; Schott, J.R.; Scaramuzza, P.; ,

    2002-01-01

    Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ??1%, reflective band absolute calibration to better than ??5%, and thermal band absolute calibration to better than ??0.6 K. The ETM+ instrument has been the most stable of any of the Landsat instruments, in both the reflective and thermal channels. To date, the best on-board calibration source for the reflective bands has been the Full Aperture Solar Calibrator, which has indicated changes of at most -1.8% to -2.0% (95% C.I.) change per year in the ETM+ gain (band 4). However, this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on ground observations, which bound the changes in gain in band 4 at -0.7% to +1.5%. Also, ETM+ stability is indicated by the monitoring of desert targets. These image-based results for four Saharan and Arabian sites, for a collection of 35 scenes over the three years since launch, bound the gain change at -0.7% to +0.5% in band 4. Thermal calibration from ground observations revealed an offset error of +0.31 W/m 2 sr um soon after launch. This offset was corrected within the U. S. ground processing system at EROS Data Center on 21-Dec-00, and since then, the band 6 on-board calibration has indicated changes of at most +0.02% to +0.04% (95% C.I.) per year. The latest ground observations have detected no remaining offset error with an RMS error of ??0.6 K. The stability and absolute calibration of the Landsat-7 ETM+ sensor make it an ideal candidate to be used as a reference source for radiometric cross-calibrating to other land remote sensing satellite systems.

  19. An absolute scale for measuring the utility of money

    Science.gov (United States)

    Thomas, P. J.

    2010-07-01

    Measurement of the utility of money is essential in the insurance industry, for prioritising public spending schemes and for the evaluation of decisions on protection systems in high-hazard industries. Up to this time, however, there has been no universally agreed measure for the utility of money, with many utility functions being in common use. In this paper, we shall derive a single family of utility functions, which have risk-aversion as the only free parameter. The fact that they return a utility of zero at their low, reference datum, either the utility of no money or of one unit of money, irrespective of the value of risk-aversion used, qualifies them to be regarded as absolute scales for the utility of money. Evidence of validation for the concept will be offered based on inferential measurements of risk-aversion, using diverse measurement data.

  20. Absolute parametric instability in a nonuniform plane plasma waveguide

    Indian Academy of Sciences (India)

    Khaled Hamed El-Shorbagy; Atef Ahmed El-Bendary; Shatha Jameel Monaquel

    2013-04-01

    The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is considered. The problem of strong magnetic field is solved in 1D nonuniform plane plasma waveguide. The equation describing the spatial part of the electric potential is obtained. Also, the growth rates and conditions of the parametric instability for periodic and aperiodic cases are obtained. It is found that the spatial nonuniformity of the plasma exerts a stabilizing effect on the API. It is shown that the growth rates of periodic and aperiodic API in nonuniform plasma are less compared to that of uniform plasma.

  1. The neurocognitive components of pitch processing: insights from absolute pitch.

    Science.gov (United States)

    Wilson, Sarah J; Lusher, Dean; Wan, Catherine Y; Dudgeon, Paul; Reutens, David C

    2009-03-01

    The natural variability of pitch naming ability in the population (known as absolute pitch or AP) provides an ideal method for investigating individual differences in pitch processing and auditory knowledge formation and representation. We have demonstrated the involvement of different cognitive processes in AP ability that reflects varying skill expertise in the presence of similar early age of onset of music tuition. These processes were related to different regions of brain activity, including those involved in pitch working memory (right prefrontal cortex) and the long-term representation of pitch (superior temporal gyrus). They reflected expertise through the use of context dependent pitch cues and the level of automaticity of pitch naming. They impart functional significance to structural asymmetry differences in the planum temporale of musicians and establish a neurobiological basis for an AP template. More generally, they indicate variability of knowledge representation in the presence of environmental fostering of early cognitive development that translates to differences in cognitive ability. PMID:18663250

  2. Absolute and specific measures of research group excellence

    CERN Document Server

    Mryglod, O; Holovatch, Yu; Berche, B

    2012-01-01

    A desirable goal of scientific management is to introduce, if it exists, a simple and reliable way to measure the scientific excellence of publicly-funded research institutions and universities to serve as a basis for their ranking and financing. While citation-based indicators and metrics are easily accessible, they are far from being universally accepted as way to automate or inform evaluation processes or to replace evaluations based on peer review. Here we consider absolute measurements of research excellence at an amalgamated, institutional level and specific measures of research excellence as performance per head. Using biology research institutions in the UK as a test case, we examine the correlations between peer-review-based and citation-based measures of research excellence on these two scales. We find that citation-based indicators are very highly correlated with peer-evaluated measures of group strength but are poorly correlated with group quality. Thus, and almost paradoxically, our analysis indi...

  3. Cosmic backgrounds of relic gravitons and their absolute normalization

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    Provided the consistency relations are not violated, the recent Bicep2 observations pin down the absolute normalization, the spectral slope and the maximal frequency of the cosmic graviton background produced during inflation. The properly normalized spectra are hereby computed from the lowest frequencies (of the order of the present Hubble rate) up to the highest frequency range in the GHz region. Deviations from the conventional paradigm cannot be excluded and are examined by allowing for different physical possibilities including, in particular, a running of the tensor spectral index, an explicit breaking of the consistency relations and a spike in the high-frequency tail of the spectrum coming either from a post-inflationary phase dominated by a stiff fluid of from the contribution of waterfall fields in a hybrid inflationary context. The direct determinations of the tensor to scalar ratio at low frequencies, if confirmed by the forthcoming observations, will also affect and constrain the high-frequencies...

  4. The use of absolute values improves performance of estimation formulae

    DEFF Research Database (Denmark)

    Redal-Baigorri, Belén; Rasmussen, Knud; Heaf, James Goya

    2013-01-01

    BACKGROUND: Estimation of Glomerular Filtration Rate (GFR) by equations such as Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) or Modification of Diet in Renal Disease (MDRD) is usually expressed as a Body Surface Area (BSA) indexed value (ml/min per 1.73 m²). This can have severe...... clinical consequences in patients with extreme body sizes, resulting in an underestimation in the case of obesity or an overestimation of GFR in the case of underweight patients. The aim of this study was to compare the performance of both estimation formula expressed in ml/min, instead of ml/min per 1.......73 m², with a reference method. METHODS: Retrospective single centre cross sectional study of 185 patients. GFR was measured with 51Cr-EDTA and estimated with CKD-EPI and MDRD. Bias, precision and accuracy of absolute estimated GFR was calculated. RESULTS: Bias of CKD-EPI and MDRD formulae expressed...

  5. Self-attraction effect and correction on three absolute gravimeters

    CERN Document Server

    Biolcati, Emanuele; Germak, Alessandro

    2012-01-01

    The perturbations of the gravitational field due to the mass distribution of an absolute gravimeter have been studied. The so called Self Attraction Effect (SAE) is crucial for the measurement accuracy, especially for the International Comparisons, and for the uncertainty budget evaluation. Three instruments have been analysed: MPG-2, FG5-238 and IMPG-02. The SAE has been calculated using a numerical method based on FEM simulation. The observed effect has been treated as an additional vertical gravity gradient. The correction (SAC) to be applied to the computed g value has been associated with the specific height level, where the measurement result is typically reported. The magnitude of the obtained corrections is of order 1E-8 m/s2.

  6. Absolute Position Total Internal Reflection Microscopy with an Optical Tweezer

    CERN Document Server

    Liu, Lulu; Rodriguez, Alejandro W; Capasso, Federico

    2014-01-01

    A non-invasive, in-situ calibration method for Total Internal Reflection Microscopy (TIRM) based on optical tweezing is presented which greatly expands the capabilities of this technique. We show that by making only simple modifications to the basic TIRM sensing setup and procedure, a probe particle's absolute position relative to a dielectric interface may be known with better than 10 nm precision out to a distance greater than 1 $\\mu$m from the surface. This represents an approximate 10x improvement in error and 3x improvement in measurement range over conventional TIRM methods. The technique's advantage is in the direct measurement of the probe particle's scattering intensity vs. height profile in-situ, rather than relying on calculations or inexact system analogs for calibration. To demonstrate the improved versatility of the TIRM method in terms of tunability, precision, and range, we show our results for the hindered near-wall diffusion coefficient for a spherical dielectric particle.

  7. Absolute rate of thermal desorption from first-principles simulation

    International Nuclear Information System (INIS)

    We present a technique for computing by first-principles simulation the absolute desorption rate γ of adsorbate molecules from a surface for any coverage and temperature. The technique is valid when the thermal equilibration rate on the surface is faster than γ, and is based on an exact expression for γ in terms of the difference of non-configurational chemical potentials of gas-phase and adsorbed molecules. This difference is expressed in terms of a potential of mean force, which is computed by constrained first-principles molecular dynamics. The technique is applied to D2O on the MgO(001) surface at low coverage, using the generalized gradient approximation (GGA) for exchange-correlation energy. Comparisons with experimental temperature programmed desorption data allow an assessment of the accuracy of the GGA for the adsorption of D2O on MgO(001). (letter to the editor)

  8. Absolute Hydration Free Energies of Ions Under Periodic Boundary Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Won, Youngdo [Hanyang Univ., Seoul (Korea, Republic of)

    2012-12-15

    The additive empirical force field of a monatomic ion is composed of the charge and the Lennard-Jones (LJ) parameters, i. e., the well-depth parameter, ε, and the distance parameter, R{sub min}, at which the potential reaches the minimum. A set of LJ parameters for monocations have been developed by utilizing molecular dynamics simulations under a solvent boundary potential (SBP). A full account of the force field development is in progress and this communication addresses consideration of the air-water phase potential in calculating the absolute free energy of hydration by calculating free energies of hydration, ΔG{sub hyd}, in the presence of periodic boundary conditions (PBC)

  9. Lagrangian Velocity Correlations and Absolute Dispersion in the Midlatitude Troposphere

    CERN Document Server

    Sukhatme, J

    2004-01-01

    Employing daily wind data from the ECMWF, we perform passive particle advection to estimate the Lagrangian velocity correlation functions (LVCF) associated with the midlatitude tropospheric flow. In particular we decompose the velocity field into time mean and transient (or eddy) components to better understand the nature of the LVCF's.A closely related quantity, the absolute dispersion (AD) is also examined. Given the anisotropy of the flow, meridional and zonal characteristics are considered separately. The zonal LVCF is seen to be non-exponential. In fact, for a broad set of intermediate timescales it is better described as a power law of the form $\\tau^{-\\alpha}$ with $ 0<\\alpha<1$. Indeed, the implied long time correlation in the zonal flow results in a superdiffusive zonal AD regime. On the other hand, the meridional LVCF decays rapidly to zero. Interestingly, before approaching to zero it shows a region of negative correlation. A physical argument based on the rotational inhibition of latitudinal...

  10. The Unity of Chemistry and Physics: Absolute Reaction Rate Theory

    Directory of Open Access Journals (Sweden)

    Hinne Hettema

    2012-12-01

    Full Text Available Henry Eyring's absolute rate theory explains the size of chemical reaction rate constants in terms of thermodynamics, statistical mechanics, and quantum chemistry. In addition it uses a number of unique concepts such as the 'transition state'. A key feature of the theory is that the explanation it provides relies on the comparison of reaction rate constant expressions derived from these individual theories. In this paper, the example is used to develop a naturalized notion of reduction and the unity of science. This characterization provides the necessary clues to the sort of inter-theoretic linkages that are present in the theory of reaction rates. The overall theory is then further characterized as a theory network, establishing connections between non-reductive notions of inter-theory connections. This characterization also sheds new light on the unity of science.

  11. Orion Exploration Flight Test-1 (EFT-1) Absolute Navigation Performance

    Science.gov (United States)

    Zanetti, Renato

    2015-01-01

    The Orion vehicle, being design to take men back to the Moon and beyond, successfully completed its first flight test, EFT-1 (Exploration Flight Test-1), on December 5th, 2014. The main objective of the test was to demonstrate the capability of re-enter into the Earth's atmosphere and safely splash-down into the pacific ocean. This un-crewed mission completes two orbits around Earth, the second of which is highly elliptical with an apogee of approximately 5908 km, higher than any vehicle designed for humans has been since the Apollo program. The trajectory was designed in order to test a high-energy re-entry similar to those crews will undergo during lunar missions. The mission overview is shown in Figure 1. The objective of this paper is to document the performance of the absolute navigation system during EFT-1 and to present its design.

  12. Absolute dimensions and masses of eclipsing binaries. V. IQ Persei

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, C.H.; Frueh, M.L.

    1985-08-01

    New photometric and spectroscopic observations of the 1.7 day eclipsing binary IQ Persei (B8 + A6) have been analyzed to yield very accurate fundamental properties of the system. Reticon spectroscopic observations obtained at McDonald Observatory were used to determine accurate radial velocities of both stars in this slightly eccentric large light-ratio binary. A new set of VR light curves obtained at McDonald Observatory were analyzed by synthesis techniques, and previously published UBV light curves were reanalyzed to yield accurate photometric orbits. Orbital parameters derived from both sets of photometric observations are in excellent agreement. The absolute dimensions, masses, luminosities, and apsidal motion period (140 yr) derived from these observations agree well with the predictions of theoretical stellar evolution models. The A6 secondary is still very close to the zero-age main sequence. The B8 primary is about one-third of the way through its main-sequence evolution. 27 references.

  13. Relative paleointensity (RPI) and oxygen isotope stratigraphy at IODP Site U1308: North Atlantic RPI stack for 1.2-2.2 Ma (NARPI-2200) and age of the Olduvai Subchron

    Science.gov (United States)

    Channell, J. E. T.; Hodell, D. A.; Curtis, J. H.

    2016-01-01

    Integrated Ocean Drilling Program (IODP) Site U1308 (49°53‧N, 24°14‧W; water depth 3871 m) provides a record of relative paleointensity (RPI) and benthic stable isotope stratigraphy back to 3.2 Ma. The record since 1.5 Ma was published previously, and here we present the interval from 1.5 Ma to 3.2 Ma (Early Pleistocene-Late Pliocene). The benthic oxygen isotope record in this interval is correlated to Marine Isotope Stage (MIS) 51 to KM2, with an apparent hiatus that removed part of the interval spanning MIS 104-G2 (2.6-2.65 Ma), at the Gauss-Matuyama boundary. The mean sedimentation rate for the 1.5-3.2 Ma period is 8.5 cm/kyr. The age model was built by correlation of the benthic oxygen isotope record to a global stack (LR04). Apart from the expected polarity reversals, three magnetic excursions are recorded: Punaruu in MIS 31/32 at 1092 ka, Gilsa in MIS 54/55 at 1584 ka, and a newly recognized excursion labeled Porcupine (after the nearby Porcupine Abyssal Plain) in MIS G6/G7 at 2737 ka. The ages of polarity reversals at Site U1308, on the LR04 time scale, are consistent with the current geomagnetic polarity timescale (GPTS) with the exception of the base of the Olduvai Subchron that occurred in MIS 73, corresponding to 1925 ka on the LR04 time scale, 25 kyr younger than in the current GPTS. The RPI record at Site U1308 is calibrated using the oxygen isotope age model, and combined with four other North Atlantic records to obtain a North Atlantic RPI stack for 1.2-2.2 Ma (NARPI-2200) that is compared with published RPI stacks: Epapis, Sint-2000 and PADM2M. For 2.2-3.2 Ma, the Site U1308 RPI record is compared with a RPI record from North Atlantic IODP Site U1314, and with the Pacific Epapis stack. The mean sedimentation rates of the North Atlantic sites in NARPI-2200 are greater (by about an order of magnitude) than most of the records incorporated in other stacks. The comparison of Epapis and NARPI-2200 yields an apparent lag for NARPI-2200 relative to

  14. Absolute Thermal SST Measurements over the Deepwater Horizon Oil Spill

    Science.gov (United States)

    Good, W. S.; Warden, R.; Kaptchen, P. F.; Finch, T.; Emery, W. J.

    2010-12-01

    Climate monitoring and natural disaster rapid assessment require baseline measurements that can be tracked over time to distinguish anthropogenic versus natural changes to the Earth system. Disasters like the Deepwater Horizon Oil Spill require constant monitoring to assess the potential environmental and economic impacts. Absolute calibration and validation of Earth-observing sensors is needed to allow for comparison of temporally separated data sets and provide accurate information to policy makers. The Ball Experimental Sea Surface Temperature (BESST) radiometer was designed and built by Ball Aerospace to provide a well calibrated measure of sea surface temperature (SST) from an unmanned aerial system (UAS). Currently, emissive skin SST observed by satellite infrared radiometers is validated by shipborne instruments that are expensive to deploy and can only take a few data samples along the ship track to overlap within a single satellite pixel. Implementation on a UAS will allow BESST to map the full footprint of a satellite pixel and perform averaging to remove any local variability due to the difference in footprint size of the instruments. It also enables the capability to study this sub-pixel variability to determine if smaller scale effects need to be accounted for in models to improve forecasting of ocean events. In addition to satellite sensor validation, BESST can distinguish meter scale variations in SST which could be used to remotely monitor and assess thermal pollution in rivers and coastal areas as well as study diurnal and seasonal changes to bodies of water that impact the ocean ecosystem. BESST was recently deployed on a conventional Twin Otter airplane for measurements over the Gulf of Mexico to access the thermal properties of the ocean surface being affected by the oil spill. Results of these measurements will be presented along with ancillary sensor data used to eliminate false signals including UV and Synthetic Aperture Radar (SAR

  15. The Absolute Calibration of the HiRes Detectors

    Science.gov (United States)

    Matthews, J. N.; Thomas, S. B.; HiRes Collaboration

    2003-07-01

    The HiRes experiment studies ultra high energy cosmic rays using the air fluorescence technique. The experiment uses large mirrors that collect the fluorescence light and fo cus it onto arrays of photomultiplier tubes (PMTs). The PMTs measure the intensity and time of arrival of the collected light. Our primary system for in situ calibration of the PMTs uses a high stability (portable light source. This source is transferred from the lab to the field where it is employed as a standard candle to calibrate the 64 detectors (>16,000 PMTs). To determine the absolute response it is necessary to understand the absolute light output of this source. We have measured the source irradiance using a hybrid photo dio de system, two NIST calibrated photo-dio des, and by observing the photo electron statistics of the PMTs. 2. Introduction The goal of the High Resolution Fly's Eye (HiRes) project is to study cosmic rays at the highest energies. An ultra high energy cosmic ray entering the earth's atmosphere collides with atmospheric nuclei triggering the development of an Extensive Air Shower (EAS). The EAS emits fluorescence light as it develops. HiRes uses the air fluorescence signal to measure properties of the primary cosmic ray particle. The fundamental detector elements in HiRes are photomultiplier tubes (PMTs). The light from an EAS is collected by large mirrors and fo cused into cameras each consisting of 256 PMTs [1]. Routine monitoring and calibration of the PMTs and associated electronics are crucial to the proper interpretation of the data. The primary system for in situ calibration of the PMTs involves the use of a high stability portable xenon flash lamp. The Roving Xenon Flasher (RXF) offers several advantages. The pulse-to-pulse variation in intensity is very small ˜0.3% and the stability over a night is better than 2%. The emission spectrum of the RXF is sufficiently broad to allow calibration over a wide range of wavelengths. It is also readily transported from

  16. The Romantic subject as an absolutely autonomous individual

    Directory of Open Access Journals (Sweden)

    Miljana Cunta

    2004-12-01

    Full Text Available This essay deals with the Romantic subject as a philosophical and literary category. Recog­ nizing the diversity and complexity of literary production in the Romantic period, this study does not attempt to treat all the many aspects of this subject, but it instead focuses upan a few: the role of nature, the status of imagination, and the subject's relation to the transcendental reality. In its rela­ tion to these issues, the Romantic subject appears as an absolutely autonomous individual, one who finds no satisfaction in claims to transcendental certainty made by any source outside the self, but relies on his immanent powers to achieve the self-awareness that is the only sure access to truth. Special attention is given to the Romantic mystical experience, whereby the subject eames into relation with the transcendental reality. Here what are termed mystical feelings are contrasted with religious feelings proper so as to stress the peculiarities of the Romantic religious experience. In providing a theoretical framewok for the religious experience, we have recourse to Rudolf Otto's definition of the "numinous," which denotes the feeling response of the subject to the divine aspect of reality. In comparison with the true religious experience, the Romantic type is seen as pseudo­- religious, thus confirming the proposed definition of the Romantic subject as a truly autonomous individual. The essay's second part contains an interpretation of selected poems by Samuel Taylor Coleridge with a view of extrapolating from them some aspects of the Romantic subject.

  17. Absolute Magnitudes of Dwarf Novae: Murmurs of Period Bounce

    CERN Document Server

    Patterson, Joseph

    2009-01-01

    We redetermine the relationship between absolute magnitude and orbital period for dwarf novae, based on 46 stars with good or excellent distance estimates. This improves upon Warner's previous relation, building upon today's improved estimates of distance and binary inclination, and greater wavelength coverage. This calibration is then applied to a set of 210 known or likely dwarf novae, to study the dependence of quiescent M_v, and time-averaged M_v, on orbital period. The resultant M_v(P_orb) curves appear to establish the existence of a lower branch of cataclysmic-variable evolution, resembling the previously known q(P_orb) relation. Stars on the lower branch seem to have the expected properties of "period bouncers" -- with a feeble secondary, faint accretion light, cool white dwarf, and long recurrence time between eruptions. They may also have higher velocities, consistent with a greater age. Some are very nearby, despite strong selection effects discriminating against the discovery of these faint stars ...

  18. Gray- and white-matter anatomy of absolute pitch possessors.

    Science.gov (United States)

    Dohn, Anders; Garza-Villarreal, Eduardo A; Chakravarty, M Mallar; Hansen, Mads; Lerch, Jason P; Vuust, Peter

    2015-05-01

    Absolute pitch (AP), the ability to identify a musical pitch without a reference, has been examined behaviorally in numerous studies for more than a century, yet only a few studies have examined the neuroanatomical correlates of AP. Here, we used MRI and diffusion tensor imaging to investigate structural differences in brains of musicians with and without AP, by means of whole-brain vertex-wise cortical thickness (CT) analysis and tract-based spatial statistics (TBSS) analysis. APs displayed increased CT in a number of areas including the bilateral superior temporal gyrus (STG), the left inferior frontal gyrus, and the right supramarginal gyrus. Furthermore, we found higher fractional anisotropy in APs within the path of the inferior fronto-occipital fasciculus, the uncinate fasciculus, and the inferior longitudinal fasciculus. The findings in gray matter support previous studies indicating an increased left lateralized posterior STG in APs, yet they differ from previous findings of thinner cortex for a number of areas in APs. Finally, we found a relation between the white-matter results and the CT in the right parahippocampal gyrus. In this study, we present novel findings in AP research that may have implications for the understanding of the neuroanatomical underpinnings of AP ability.

  19. Redetermined structure, intermolecular interactions and absolute configuration of royleanone

    Directory of Open Access Journals (Sweden)

    Hoong-Kun Fun

    2011-05-01

    Full Text Available The structure of the title diterpenoid, C20H28O3, {systematic name: (4bS,8aS-3-hydroxy-2-isopropyl-4b,8,8-trimethyl-4b,5,6,7,8,8a,9,10-octahydrophenanthrene-1,4-dione} is confirmed [Eugster et al. (1993. Private communication (refcode HACGUN. CCDC, Union Road, Cambridge] and its packing is now described. Its absolute structure was established by refinement against data collected with Cu radiation: the two stereogenic centres both have S configurations. One cyclohexane ring adopts a chair conformation whereas the other cyclohexane ring is in a half-chair conformation and the benzoquinone ring is slightly twisted. An intramolecular O—H...O hydrogen bond generates an S(5 ring motif. In the crystal, molecules are linked into chains along [010] by O—H...O hydrogen bonds and weak C—H...O interactions. The packing also features C...O [3.131 (3 Å] short contacts.

  20. Measuring the absolute quantum efficiency of luminescent materials

    Energy Technology Data Exchange (ETDEWEB)

    Rohwer, Lauren Shea [Sandia National Laboratories, P.O. Box 5800, MS-0892, Albuquerque, NM 87185-0892 (United States)]. E-mail: leshea@sandia.gov; Martin, James E. [Sandia National Laboratories, P.O. Box 5800, MS-0892, Albuquerque, NM 87185-0892 (United States)

    2005-11-15

    A measurement system and mathematical procedure are developed for determining the absolute quantum efficiency (QE), of luminescent materials. This technique, based on absorption of diffuse light within an integrating sphere, is applied to fluorescent laser dyes and conventional phosphor powders. The system described is tested for excitation in the near-UV and blue regions, but can be applied to higher energy excitation (UV), as well as lower energy excitation in the visible to near-IR, with the appropriate photodetectors and optical filters. The system was tested on both liquid and solid samples such as Coumarin 500 (CM500) dye in methanol and ethyl acetate; Rhodamine 6G in ethanol; and a variety of powder phosphors. The QE of quinine sulfate dihydrate solution (5x10{sup -3} M in 0.1 N H{sub 2}SO{sub 4}), a NIST fluorescence standard, was found to be in good agreement with the NIST value under 390 nm excitation. The accuracy of this measurement technique is acceptable for samples with absorption cross sections greater than {approx}6 mm{sup 2}.

  1. Dichotomy and perceptual distortions in absolute pitch ability.

    Science.gov (United States)

    Athos, E Alexandra; Levinson, Barbara; Kistler, Amy; Zemansky, Jason; Bostrom, Alan; Freimer, Nelson; Gitschier, Jane

    2007-09-11

    Absolute pitch (AP) is the rare ability to identify the pitch of a tone without the aid of a reference tone. Understanding both the nature and genesis of AP can provide insights into neuroplasticity in the auditory system. We explored factors that may influence the accuracy of pitch perception in AP subjects both during the development of the trait and in later age. We used a Web-based survey and a pitch-labeling test to collect perceptual data from 2,213 individuals, 981 (44%) of whom proved to have extraordinary pitch-naming ability. The bimodal distribution in pitch-naming ability signifies AP as a distinct perceptual trait, with possible implications for its genetic basis. The wealth of these data has allowed us to uncover unsuspected note-naming irregularities suggestive of a "perceptual magnet" centered at the note "A." In addition, we document a gradual decline in pitch-naming accuracy with age, characterized by a perceptual shift in the "sharp" direction. These findings speak both to the process of acquisition of AP and to its stability.

  2. Cosmic backgrounds of relic gravitons and their absolute normalization

    Science.gov (United States)

    Giovannini, Massimo

    2014-11-01

    Provided the consistency relations are not violated, the recent BICEP2 observations pin down the absolute normalization, the spectral slope and the maximal frequency of the cosmic graviton background produced during inflation. The properly normalized spectra are hereby computed from the lowest frequencies (of the order of the present Hubble rate) up to the highest frequency range in the GHz region. Deviations from the conventional paradigm cannot be excluded and are examined by allowing for different physical possibilities including, in particular, a running of the tensor spectral index, an explicit breaking of the consistency relations and a spike in the high-frequency tail of the spectrum coming either from a post-inflationary phase dominated by a stiff fluid or from the contribution of waterfall fields in a hybrid inflationary context. The direct determinations of the tensor to scalar ratio at low frequencies, if confirmed by the forthcoming observations, will also affect and constrain the high-frequency uncertainties. The limits on the cosmic graviton backgrounds coming from wide-band interferometers (such as LIGO/Virgo, LISA and BBO/DECIGO) together with a more accurate scrutiny of the tensor B-mode polarization at low frequencies will set direct bounds on the post-inflationary evolution and on other unconventional completions of the standard lore.

  3. Absolute measures of the completeness of the fossil record.

    Science.gov (United States)

    Foote, M; Sepkoski, J J

    1999-04-01

    Measuring the completeness of the fossil record is essential to understanding evolution over long timescales, particularly when comparing evolutionary patterns among biological groups with different preservational properties. Completeness measures have been presented for various groups based on gaps in the stratigraphic ranges of fossil taxa and on hypothetical lineages implied by estimated evolutionary trees. Here we present and compare quantitative, widely applicable absolute measures of completeness at two taxonomic levels for a broader sample of higher taxa of marine animals than has previously been available. We provide an estimate of the probability of genus preservation per stratigraphic interval, and determine the proportion of living families with some fossil record. The two completeness measures use very different data and calculations. The probability of genus preservation depends almost entirely on the Palaeozoic and Mesozoic records, whereas the proportion of living families with a fossil record is influenced largely by Cenozoic data. These measurements are nonetheless highly correlated, with outliers quite explicable, and we find that completeness is rather high for many animal groups.

  4. Revised absolute amplitude calibration of the LOPES experiment

    CERN Document Server

    Link, K; Apel, W D; Arteaga-Velázquez, J C; Bähren, L; Bekk, K; Bertaina, M; Biermann, P L; Blümer, J; Bozdog, H; Brancus, I M; Cantoni, E; Chiavassa, A; Daumiller, K; de Souza, V; Di Pierro, F; Doll, P; Engel, R; Falcke, H; Fuchs, B; Gemmeke, H; Grupen, C; Haungs, A; Heck, D; Hiller, R; Hörandel, J R; Horneffer, A; Huber, D; Isar, P G; Kampert, K-H; Kang, D; Krömer, O; Kuijpers, J; Łuczak, P; Ludwig, M; Mathes, H J; Melissas, M; Morello, C; Oehlschläger, J; Palmieri, N; Pierog, T; Rautenberg, J; Rebel, H; Roth, M; Rühle, C; Saftoiu, A; Schieler, H; Schmidt, A; Schoo, S; Schröder, F G; Sima, O; Toma, G; Trinchero, G C; Weindl, A; Wochele, J; Zabierowski, J; Zensus, J A

    2015-01-01

    One of the main aims of the LOPES experiment was the evaluation of the absolute amplitude of the radio signal of air showers. This is of special interest since the radio technique offers the possibility for an independent and highly precise determination of the energy scale of cosmic rays on the basis of signal predictions from Monte Carlo simulations. For the calibration of the amplitude measured by LOPES we used an external source. Previous comparisons of LOPES measurements and simulations of the radio signal amplitude predicted by CoREAS revealed a discrepancy of the order of a factor of two. A re-measurement of the reference calibration source, now performed for the free field, was recently performed by the manufacturer. The updated calibration values lead to a lowering of the reconstructed electric field measured by LOPES by a factor of $2.6 \\pm 0.2$ and therefore to a significantly better agreement with CoREAS simulations. We discuss the updated calibration and its impact on the LOPES analysis results.

  5. Computational Methodology for Absolute Calibration Curves for Microfluidic Optical Analyses

    Directory of Open Access Journals (Sweden)

    Mona E. Zaghloul

    2010-07-01

    Full Text Available Optical fluorescence and absorption are two of the primary techniques used for analytical microfluidics. We provide a thorough yet tractable method for computing the performance of diverse optical micro-analytical systems. Sample sizes range from nano- to many micro-liters and concentrations from nano- to milli-molar. Equations are provided to trace quantitatively the flow of the fundamental entities, namely photons and electrons, and the conversion of energy from the source, through optical components, samples and spectral-selective components, to the detectors and beyond. The equations permit facile computations of calibration curves that relate the concentrations or numbers of molecules measured to the absolute signals from the system. This methodology provides the basis for both detailed understanding and improved design of microfluidic optical analytical systems. It saves prototype turn-around time, and is much simpler and faster to use than ray tracing programs. Over two thousand spreadsheet computations were performed during this study. We found that some design variations produce higher signal levels and, for constant noise levels, lower minimum detection limits. Improvements of more than a factor of 1,000 were realized.

  6. Scanning micro-resonator direct-comb absolute spectroscopy

    CERN Document Server

    Gambetta, Alessio; Gatti, Davide; Laporta, Paolo; Galzerano, Gianluca

    2016-01-01

    Direct optical frequency Comb Spectroscopy (DCS) is proving to be a fundamental tool in many areas of science and technology thanks to its unique performance in terms of ultra-broadband, high-speed detection and frequency accuracy, allowing for high-fidelity mapping of atomic and molecular energy structure. Here we present a novel DCS approach based on a scanning Fabry-Perot micro-cavity resonator (SMART) providing a simple, compact and accurate method to resolve the mode structure of an optical frequency comb. The SMART approach, while drastically reducing system complexity, allows for a straightforward absolute calibration of the optical-frequency axis with an ultimate resolution limited by the micro-resonator resonance linewidth and can be used in any spectral region from XUV to THz. An application to high-precision spectroscopy of acetylene at 1.54 um is presented, demonstrating frequency resolution as low as 20 MHz with a single-scan optical bandwidth up to 1 THz in 20-ms measurement time and a noise-equ...

  7. Absolute parallelism, modified gravity, and suppression of gravitational short waves

    CERN Document Server

    Zhogin, I L

    2011-01-01

    There is a unique variant of Absolute Parallelism, which is very simple as it has no free parameters: nothing (nor D=5) can be changed if to keep the theory safe from emerging singularities of solutions. On the contrary, eternal solutions of this theory, due to the linear instability of the trivial solution, should be of great complexity which can in some scenarios (with a set of slowly varying parameters of solutions) provide a few phenomenological models including a modified (better to say, new or another) gravity and an expanding-shell cosmology (the longitudinal polarization gives the anti-Milne model). The former looks (mostly) like a variant of tensor-Ricci-squared gravity on a brane of a huge scale L along the extra-dimension. The correction to Newton's law of gravity, which depends in this theory on two parameters (bi-Laplace equation) and behaves as 1/r on large scales, r>L (kpc>L>pc), can start from zero (the Rindler term vanishes) if a constraint is imposed on these parameters. On further considera...

  8. Monochromator-Based Absolute Calibration of a Standard Radiation Thermometer

    Science.gov (United States)

    Mantilla, J. M.; Hernanz, M. L.; Campos, J.; Martín, M. J.; Pons, A.; del Campo, D.

    2014-04-01

    Centro Español de Metrología (CEM) is disseminating the International Temperature Scale (ITS-90), at high temperatures, by using the fixed points of Ag and Cu and a standard radiation thermometer. However, the future mise-en-pratique for the definition of the kelvin ( MeP-K) will include the dissemination of the kelvin by primary methods and by indirect approximations capable of exceptionally low uncertainties or increased reliability. Primary radiometry is, at present, able to achieve uncertainties competitive with the ITS-90 above the silver point with one of the possible techniques the calibration for radiance responsivity of an imaging radiometer (radiance method). In order to carry out this calibration, IO-CSIC (Spanish Designated Institute for luminous intensity and luminous flux) has collaborated with CEM, allowing traceability to its cryogenic radiometer. A monochromator integrating sphere-based spectral comparator facility has been used to calibrate one of the CEM standard radiation thermometers. The absolute calibrated standard radiation thermometer has been used to determine the temperatures of the fixed points of Cu, Co-C, Pt-C, and Re-C. The results obtained are 1357.80 K, 1597.10 K, 2011.66 K, and 2747.64 K, respectively, with uncertainties ranging from 0.4 K to 1.1 K.

  9. A nonmusical paradigm for identifying absolute pitch possessors

    Science.gov (United States)

    Ross, David A.; Olson, Ingrid R.; Marks, Lawrence E.; Gore, John C.

    2004-09-01

    The ability to identify and reproduce sounds of specific frequencies is remarkable and uncommon. The etiology and defining characteristics of this skill, absolute pitch (AP), have been very controversial. One theory suggests that AP requires a specific type of early musical training and that the ability to encode and remember tones depends on these learned musical associations. An alternate theory argues that AP may be strongly dependent on hereditary factors and relatively independent of musical experience. To date, it has been difficult to test these hypotheses because all previous paradigms for identifying AP have required subjects to employ knowledge of musical nomenclature. As such, these tests are insensitive to the possibility of discovering AP in either nonmusicians or musicians of non-Western training. Based on previous literature in pitch memory, a paradigm is presented that is intended to distinguish between AP possessors and nonpossessors independent of the subjects' musical experience. The efficacy of this method is then tested with 20 classically defined AP possessors and 22 nonpossessors. Data from these groups strongly support the validity of the paradigm. The use of a nonmusical paradigm to identify AP may facilitate research into many aspects of this phenomenon.

  10. A Maximum Likelihood Approach to Least Absolute Deviation Regression

    Directory of Open Access Journals (Sweden)

    Yinbo Li

    2004-09-01

    Full Text Available Least absolute deviation (LAD regression is an important tool used in numerous applications throughout science and engineering, mainly due to the intrinsic robust characteristics of LAD. In this paper, we show that the optimization needed to solve the LAD regression problem can be viewed as a sequence of maximum likelihood estimates (MLE of location. The derived algorithm reduces to an iterative procedure where a simple coordinate transformation is applied during each iteration to direct the optimization procedure along edge lines of the cost surface, followed by an MLE of location which is executed by a weighted median operation. Requiring weighted medians only, the new algorithm can be easily modularized for hardware implementation, as opposed to most of the other existing LAD methods which require complicated operations such as matrix entry manipulations. One exception is Wesolowsky's direct descent algorithm, which among the top algorithms is also based on weighted median operations. Simulation shows that the new algorithm is superior in speed to Wesolowsky's algorithm, which is simple in structure as well. The new algorithm provides a better tradeoff solution between convergence speed and implementation complexity.

  11. Comparison of available measurements of the absolute fluorescence yield

    CERN Document Server

    Rosado, J; Arqueros, F

    2010-01-01

    The uncertainty in the absolute value of the fluorescence yield is still one of the main contributions to the total error in the reconstruction of the primary energy of ultra-energetic air showers using the fluorescence technique. A significant number of experimental values of the fluorescence yield have been published in the last years, however reported results are given very often in different units (photons/MeV or photons/m) and for different wavelength intervals. In this work we present a comparison of available results normalized to its value in photons/MeV for the 337 nm band at 800 hPa and 293 K. Possible sources of systematic errors on these measurements are discussed. In particular, the conversion of photons/m to photons/MeV requires an accurate determination of the energy deposited by the electrons in the field of view of the experimental setup. We have calculated the energy deposition for each experiment by means of a detailed Monte Carlo simulation including when possible the geometrical details o...

  12. Surface Characterization of pNIPAM Under Varying Absolute Humidity

    Science.gov (United States)

    Chhabra, Arnav; Kanapuram, Ravitej; Leva, Harrison; Trejo, Juan; Kim, Tae Jin; Hidrovo, Carlos

    2012-11-01

    Poly(N-isopropylacrylamide) has become ubiquitously known as a ``smart'' polymer, showing many promising applications in tissue engineering and drug delivery systems. These applications are particularly reliant on its trenchant, thermally induced hydrophilic-hydrophobic transition that occurs at the lower critical solution temperature (LCST). This feature imparts the pNIPAM programmable adsorption and release capabilities, thus eliminating the need for additional enzymes when removing cells from pNIPAM coated surfaces and leaving the extracellular matrix proteins of the cells largely untouched. The dependence of the LCST on molecular weight, solvent systems, and various salts has been studied extensively. However, what has not been explored is the effect of humidity on the characteristic properties of the polymer, specifically the LCST and the magnitude of the hydrophilic-hydrophobic transition. We studied the surface energy variation of pNIPAM as a function of humidity by altering the absolute humidity and keeping the ambient temperature constant. Our experiments were conducted inside a cuboidal environmental chamber with control over the temperature and humidity inside the chamber. A controlled needle was employed to dispense size-regulated droplets. Throughout this process, a CCD camera was used to image the droplet and the static contact angle was determined using image processing techniques. The behavior of pNIPAM as a function of humidity is presented and discussed.

  13. Large eddy simulation predictions of absolutely unstable round hot jet

    Science.gov (United States)

    Boguslawski, A.; Tyliszczak, A.; Wawrzak, K.

    2016-02-01

    The paper presents a novel view on the absolute instability phenomenon in heated variable density round jets. As known from literature the global instability mechanism in low density jets is released when the density ratio is lower than a certain critical value. The existence of the global modes was confirmed by an experimental evidence in both hot and air-helium jets. However, some differences in both globally unstable flows were observed concerning, among others, a level of the critical density ratio. The research is performed using the Large Eddy Simulation (LES) method with a high-order numerical code. An analysis of the LES results revealed that the inlet conditions for the velocity and density distributions at the nozzle exit influence significantly the critical density ratio and the global mode frequency. Two inlet velocity profiles were analyzed, i.e., the hyperbolic tangent and the Blasius profiles. It was shown that using the Blasius velocity profile and the uniform density distribution led to a significantly better agreement with the universal scaling law for global mode frequency.

  14. Gray- and white-matter anatomy of absolute pitch possessors.

    Science.gov (United States)

    Dohn, Anders; Garza-Villarreal, Eduardo A; Chakravarty, M Mallar; Hansen, Mads; Lerch, Jason P; Vuust, Peter

    2015-05-01

    Absolute pitch (AP), the ability to identify a musical pitch without a reference, has been examined behaviorally in numerous studies for more than a century, yet only a few studies have examined the neuroanatomical correlates of AP. Here, we used MRI and diffusion tensor imaging to investigate structural differences in brains of musicians with and without AP, by means of whole-brain vertex-wise cortical thickness (CT) analysis and tract-based spatial statistics (TBSS) analysis. APs displayed increased CT in a number of areas including the bilateral superior temporal gyrus (STG), the left inferior frontal gyrus, and the right supramarginal gyrus. Furthermore, we found higher fractional anisotropy in APs within the path of the inferior fronto-occipital fasciculus, the uncinate fasciculus, and the inferior longitudinal fasciculus. The findings in gray matter support previous studies indicating an increased left lateralized posterior STG in APs, yet they differ from previous findings of thinner cortex for a number of areas in APs. Finally, we found a relation between the white-matter results and the CT in the right parahippocampal gyrus. In this study, we present novel findings in AP research that may have implications for the understanding of the neuroanatomical underpinnings of AP ability. PMID:24304583

  15. Extension of the absolute flux density scale to 22.285 GHz. [radio astronomy

    Science.gov (United States)

    Janssen, M. A.; Golden, L. M.; Welch, W. J.

    1974-01-01

    Extending the absolute flux density scale at microwave wavelengths, the absolute flux densities at 22.285 GHz of several standard sources were determined using the absolute calibrations of the 6.1 meter antenna of the Hat Creek Observatory. Interpolation formulas for each nonthermal standard source have been derived by combining these data with those determined at lower frequencies. The suitability of employing the standard sources for calibrating other antennas is discussed.

  16. Accounting for recent trends in absolute poverty in Poland: A decomposition analysis

    OpenAIRE

    Michał Brzeziński

    2011-01-01

    This paper uses several decomposition of poverty and poverty changes to identify factors explaining recent changes in absolute income and consumption poverty in Poland during 1998−2008. Shapley decompositions of poverty changes into growth and redistribution components show that fast economic growth was the main source of a radical fall in absolute poverty since 2005. Distributional changes had a more profound effect on absolute poverty during 1998−2005. Sectoral decompositions of poverty sug...

  17. Tests of Non-Equivalence among Absolutely Nonsingular Tensors through Geometric Invariants

    OpenAIRE

    Sakata, Toshio; Maehra, Kazumitsu; Sasaki, Takeshi; Sumi, Toshio; MIYAZAKI, Mitsuhiro; Watanabe, Yoshitaka

    2010-01-01

    4x4x3 absolutely nonsingular tensors are characterized by their determinant polynomial. Non-quivalence among absolutely nonsingular tensors with respect to a class of linear transformations, which do not chage the tensor rank,is studied. It is shown theoretically that affine geometric invariants of the constant surface of a determinant polynomial is useful to discriminate non-equivalence among absolutely nonsingular tensors. Also numerical caluculations are presented and these invariants are ...

  18. A new index combining the absolute and relative aspects of income poverty: Theory and application

    OpenAIRE

    DECERF, Benoit

    2015-01-01

    I derive a new index combining the absolute and relative aspects of income poverty. Earning a larger income decreases one’s absolute poverty but experiencing a larger income inequality increases one’s relative poverty. Provided that the individual poverty is not computed based on the normalized income, the two aspects can be weighed such that absolutely poor individuals are always considered poorer than relatively poor individuals. Only the value of poverty aversion associated with the Povert...

  19. Binomial Distribution Sample Confidence Intervals Estimation 7. Absolute Risk Reduction and ARR-like Expressions

    Directory of Open Access Journals (Sweden)

    Andrei ACHIMAŞ CADARIU

    2004-08-01

    Full Text Available Assessments of a controlled clinical trial suppose to interpret some key parameters as the controlled event rate, experimental event date, relative risk, absolute risk reduction, relative risk reduction, number needed to treat when the effect of the treatment are dichotomous variables. Defined as the difference in the event rate between treatment and control groups, the absolute risk reduction is the parameter that allowed computing the number needed to treat. The absolute risk reduction is compute when the experimental treatment reduces the risk for an undesirable outcome/event. In medical literature when the absolute risk reduction is report with its confidence intervals, the method used is the asymptotic one, even if it is well know that may be inadequate. The aim of this paper is to introduce and assess nine methods of computing confidence intervals for absolute risk reduction and absolute risk reduction – like function.Computer implementations of the methods use the PHP language. Methods comparison uses the experimental errors, the standard deviations, and the deviation relative to the imposed significance level for specified sample sizes. Six methods of computing confidence intervals for absolute risk reduction and absolute risk reduction-like functions were assessed using random binomial variables and random sample sizes.The experiments shows that the ADAC, and ADAC1 methods obtains the best overall performance of computing confidence intervals for absolute risk reduction.

  20. Absolute homogeneity test of Kelantan catchment precipitation series

    Science.gov (United States)

    Ros, Faizah Che; Tosaka, Hiroyuki; Sasaki, Kenji; Sidek, Lariyah Mohd; Basri, Hidayah

    2015-05-01

    Along the Kelantan River in north east of Malaysia Peninsular, there are several areas often damaged by flood during north-east monsoon season every year. It is vital to predict the expected behavior of precipitation and river runoff for reducing flood damages of the area under rapid urbanization and future planning. Nevertheless, the accuracy and reliability of any hydrological and climate studies vary based on the quality of the data used. The factors causing variations on these data are the method of gauging and data collection, stations environment, station relocation and the reliability of the measurement tool affect the homogenous precipitation records. Hence in this study, homogeneity of long precipitation data series is checked via the absolute homogeneity test consisting of four methods namely Pettitt test, standard normal homogeneity test (SNHT), Buishand range test and Von Neumann ratio test. For homogeneity test, the annual rainfall amount from the daily precipitation records at stations located in Kelantan operated by Department of Irrigation and Drainage Malaysia were considered in this study. The missing values were completed using the correlation and regression and inverse distance method. The data network consists of 103 precipitation gauging stations where 31 points are inactive, 6 gauging stations had missing precipitation values more than five years in a row and 16 stations have records less than twenty years. So total of 50 stations gauging stations were evaluated in this analysis. With the application of the mentioned methods and further graphical analysis, inhomogeneity was detected at 4 stations and 46 stations are found to be homogeneous.

  1. Absolute pitch: effects of timbre on note-naming ability.

    Directory of Open Access Journals (Sweden)

    Patrícia Vanzella

    Full Text Available BACKGROUND: Absolute pitch (AP is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names, it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP possessors to identify. A musician's first instrument may also affect performance and extend the sensitive period for acquiring accurate AP. METHODS/PRINCIPAL FINDINGS: A large sample of AP possessors was recruited on-line. Participants were required to identity test tones presented in four different timbres: piano, pure tone, natural (sung voice, and synthesized voice. Note-naming accuracy was better for non-vocal (piano and pure tones than for vocal (natural and synthesized voices test tones. This difference could not be attributed solely to vibrato (pitch variation, which was more pronounced in the natural voice than in the synthesized voice. Although starting music lessons by age 7 was associated with enhanced note-naming accuracy, equivalent abilities were evident among listeners who started music lessons on piano at a later age. CONCLUSIONS/SIGNIFICANCE: Because the human voice is inextricably linked to language and meaning, it may be processed automatically by voice-specific mechanisms that interfere with note naming among AP possessors. Lessons on piano or other fixed-pitch instruments appear to enhance AP abilities and to extend the sensitive period for exposure to music in order to develop accurate AP.

  2. The absolute magnitude distribution of Kuiper Belt objects

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, Wesley C. [Herzberg Institute of Astrophysics, 5071 West Saanich Road, Victoria, BC V9E 2E7 (Canada); Brown, Michael E. [Division of Geological and Planetary Sciences, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Morbidelli, Alessandro [Laboratoire Lagrange, UMR7293, Université de Nice Sophia-Antipolis, CNRS, Observatoire de la Côte d' Azur, BP 4229, F-06304 Nice (France); Parker, Alex [Department of Astronomy, University of California at Berkeley, Berkeley, CA 94720 (United States); Batygin, Konstantin, E-mail: wesley.fraser@nrc.ca [Institute for Theory and Computation, Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS 51, Cambridge, MA 02138 (United States)

    2014-02-20

    Here we measure the absolute magnitude distributions (H-distribution) of the dynamically excited and quiescent (hot and cold) Kuiper Belt objects (KBOs), and test if they share the same H-distribution as the Jupiter Trojans. From a compilation of all useable ecliptic surveys, we find that the KBO H-distributions are well described by broken power laws. The cold population has a bright-end slope, α{sub 1}=1.5{sub −0.2}{sup +0.4}, and break magnitude, H{sub B}=6.9{sub −0.2}{sup +0.1} (r'-band). The hot population has a shallower bright-end slope of, α{sub 1}=0.87{sub −0.2}{sup +0.07}, and break magnitude H{sub B}=7.7{sub −0.5}{sup +1.0}. Both populations share similar faint-end slopes of α{sub 2} ∼ 0.2. We estimate the masses of the hot and cold populations are ∼0.01 and ∼3 × 10{sup –4} M {sub ⊕}. The broken power-law fit to the Trojan H-distribution has α{sub 1} = 1.0 ± 0.2, α{sub 2} = 0.36 ± 0.01, and H {sub B} = 8.3. The Kolmogorov-Smirnov test reveals that the probability that the Trojans and cold KBOs share the same parent H-distribution is less than 1 in 1000. When the bimodal albedo distribution of the hot objects is accounted for, there is no evidence that the H-distributions of the Trojans and hot KBOs differ. Our findings are in agreement with the predictions of the Nice model in terms of both mass and H-distribution of the hot and Trojan populations. Wide-field survey data suggest that the brightest few hot objects, with H{sub r{sup ′}}≲3, do not fall on the steep power-law slope of fainter hot objects. Under the standard hierarchical model of planetesimal formation, it is difficult to account for the similar break diameters of the hot and cold populations given the low mass of the cold belt.

  3. Study on the effect factor of the absolute fission rates measured by depleted uranium fission chamber

    International Nuclear Information System (INIS)

    The absolute fission rates was measured by the depleted uranium fission chamber. The efficiency of the fission fragments recorded in the fission chamber was analyzed. The factor influencing absolute fission rates was studied in the experiment, including the disturbing effect between detectors and the effect of the structural material of the fission chamber, etc

  4. The Relation between the Absolute Level of Parenting and Differential Parental Treatment with Adolescent Siblings' Adjustment

    Science.gov (United States)

    Tamrouti-Makkink, Ilse D.; Dubas, Judith Semon; Gerris, Jan R. M.; van Aken, Marcel A. G.

    2004-01-01

    Background: The present study extends existing studies on the role of differential parental treatment in explaining individual differences in adolescent problem behaviors above the absolute level of parenting and clarifies the function of gender of the child, birth rank and gender constellation of the sibling dyads. Method: The absolute level of…

  5. The Mauna Kea Observatories Near-Infrared Filter Set. III. Isophotal Wavelengths and Absolute Calibration

    CERN Document Server

    Tokunaga, A T

    2005-01-01

    The isophotal wavelengths, flux densities, and AB magnitudes for Vega (alpha Lyr) are presented for the Mauna Kea Observatories near-infrared filter set. We show that the near-infrared absolute calibration for Vega determined by Cohen et al. and Megessier are consistent within the uncertainties, so that either absolute calibration may be used.

  6. Generalized Fourier representation of the absolutely continuous part of a selfadjoint operator

    OpenAIRE

    Nagao, Take-Yuki

    2011-01-01

    We formulate and prove the existence and uniqueness of the generalized Fourier transform associated with the absolutely continuous part of an arbitrary selfadjoint operator on a separable Hilbert space. To this end we develop a novel method to decompose an absolutely continuous operator into a variable fiber direct integral of selfadjoint operators.

  7. 如何学好绝对值%How to Learn the Absolute Value

    Institute of Scientific and Technical Information of China (English)

    张永红

    2014-01-01

    Seventh grade math absolute value is a very important concept, students learn how to make the absolute value is the topic of this article.%绝对值是七年级数学中一个很重要的概念,如何让学生学好绝对值是探讨的话题。

  8. Strong laws for generalized absolute Lorenz curves when data are stationary and ergodic sequences

    NARCIS (Netherlands)

    Helmers, R.; Zitikis, R.

    2004-01-01

    We consider generalized absolute Lorenz curves that include, as special cases, classical and generalized L - statistics as well as absolute or, in other words, generalized Lorenz curves. The curves are based on strictly stationary and ergodic sequences of random variables. Most of the previous resul

  9. 47 CFR 64.1160 - Absolution procedures where the subscriber has not paid charges.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Absolution procedures where the subscriber has... Preferred Telecommunications Service Providers § 64.1160 Absolution procedures where the subscriber has not paid charges. (a) This section shall only apply after a subscriber has determined that an...

  10. High absolute risks and predictors of venous and arterial thromboembolic events in patients with nephrotic syndrome

    NARCIS (Netherlands)

    Mahmoodi, Bakhtawar K.; ten Kate, Min Ki; Waanders, Femke; Veeger, Nic J. G. M.; Brouwer, Jan-Leendert P.; Vogt, Liffert; Navis, Gerjan; van der Meer, Jan

    2008-01-01

    Background-No data are available on the absolute risk of either venous thromboembolism (VTE) or arterial thromboembolism (ATE) in patients with nephrotic syndrome. Reported risks are based on multiple case reports and small studies with mostly short-term follow-up. We assessed the absolute risk of V

  11. Absolute exponential stability analysis of delayed bi-directional associative memory neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lou Xuyang [Research Center of Control Science and Engineering, Southern Yangtze University, 1800 Lihu Road, Wuxi, Jiangsu 214122 (China); Cui Baotong [Research Center of Control Science and Engineering, Southern Yangtze University, 1800 Lihu Road, Wuxi, Jiangsu 214122 (China)]. E-mail: btcui@sohu.com

    2007-02-15

    The problem of absolute exponential stability for delayed bi-directional associative memory neural networks with time delay is investigated via Lyapunov stability theory. A new sufficient condition ensuring existence and uniqueness of equilibrium and its absolute exponential stability is derived. An illustrative example is given to demonstrate the effectiveness of the obtained results.

  12. Absolute stability of nonlinear systems with time delays and applications to neural networks

    Directory of Open Access Journals (Sweden)

    Xinzhi Liu

    2001-01-01

    Full Text Available In this paper, absolute stability of nonlinear systems with time delays is investigated. Sufficient conditions on absolute stability are derived by using the comparison principle and differential inequalities. These conditions are simple and easy to check. In addition, exponential stability conditions for some special cases of nonlinear delay systems are discussed. Applications of those results to cellular neural networks are presented.

  13. Usage tests of oak moss absolutes containing high and low levels of atranol and chloroatranol.

    Science.gov (United States)

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-07-01

    Atranol and chloroatranol are strong contact allergens in oak moss absolute, a lichen extract used in perfumery. Fifteen subjects with contact allergy to oak moss absolute underwent a repeated open application test (ROAT) using solutions of an untreated oak moss absolute (sample A) and an oak moss absolute with reduced content of atranol and chloroatranol (sample B). All subjects were in addition patch-tested with serial dilutions of samples A and B. Statistically significantly more subjects reacted to sample A than to sample B in the patch tests. No corresponding difference was observed in the ROAT, though there was a significant difference in the time required to elicit a positive reaction. Still, the ROAT indicates that the use of a cosmetic product containing oak moss absolute with reduced levels of atranol and chloroatranol is capable of eliciting an allergic reaction in previously sensitised individuals. PMID:24287679

  14. Absolute dose determinations in electron beams - Intercomparison of methodologies

    International Nuclear Information System (INIS)

    The use of plane parallel ionization chambers for the dosimetry of electron beams has been extensively recognized in national and international recommendations and codes of practice. The construction details of different chambers and their influence on the measure, which should be converted in suitable perturbation factors, have also been published. Updated information, new data, refined investigations have recently been gathered in IAEA TRS 398 where the major efforts of Primary Standard Dosimetry Laboratories (PSDLs) in providing calibration factors in terms of absorbed dose to water at a reference quality is reflected. From the users point of view, and specially concerning electron beams, one can probably get confused with different methodologies and procedures in order to accurately determine absorbed dose to water. The aim of this work is to explore the different methodologies and procedures concerning absolute dose determinations, in a hospital and using different chambers, in order to appreciate the relative deviations in absolute dose values. Despite the fact that Markus chamber does not meet all the minimum requirements namely concerning scattering perturbation effects due to the geometry and dimensions of the guard electrode, it is still a quite used chamber type in current clinical practice. So we have included dose determinations with this plane parallel chamber (PTW 23343) and also with a Roos chamber (PTW 34001). Markus chamber is provided with a standard calibration certificate in terms of absorbed dose to water (NW) and also in terms of absorbed dose to air (NA), referred to a high energy electron beam whereas Roos chamber has a calibration factor in terms of absorbed dose to water referred to 60Co. Starting from these materials different methodologies have been applied: i) Using NA of Markus chamber according to the users instruction manual which refers DGMP Report No.6 Praktische Dosimetrie von Elektronenstrahlung und ultraharter Rontgenstrahlung

  15. On the absolute calibration of SO2 cameras

    Directory of Open Access Journals (Sweden)

    J. Zielcke

    2012-09-01

    Full Text Available Sulphur dioxide emission flux measurements are an important tool for volcanic monitoring and eruption risk assessment. The SO2 camera technique remotely measures volcanic emissions by analysing the ultraviolet absorption of SO2 in a narrow spectral window between 305 nm and 320 nm using solar radiation scattered in the atmosphere. The SO2 absorption is selectively detected by mounting band-pass interference filters in front of a two-dimensional, UV-sensitive CCD detector. While this approach is simple and delivers valuable insights into the two-dimensional SO2 distribution, absolute calibration has proven to be difficult. An accurate calibration of the SO2 camera (i.e., conversion from optical density to SO2 column density, CD is crucial to obtain correct SO2 CDs and flux measurements that are comparable to other measurement techniques and can be used for volcanological applications. The most common approach for calibrating SO2 camera measurements is based on inserting quartz cells (cuvettes containing known amounts of SO2 into the light path. It has been found, however, that reflections from the windows of the calibration cell can considerably affect the signal measured by the camera. Another possibility for calibration relies on performing simultaneous measurements in a small area of the camera's field-of-view (FOV by a narrow-field-of-view Differential Optical Absorption Spectroscopy (NFOV-DOAS system. This procedure combines the very good spatial and temporal resolution of the SO2 camera technique with the more accurate column densities obtainable from DOAS measurements. This work investigates the uncertainty of results gained through the two commonly used, but quite different calibration methods (DOAS and calibration cells. Measurements with three different instruments, an SO2 camera, a NFOV-DOAS system and an Imaging DOAS (IDOAS, are presented. We compare the calibration-cell approach with the calibration from the NFOV-DOAS system. The

  16. Study on comparison between absolute and relative input energy spectra and effects of ductility factor

    Institute of Scientific and Technical Information of China (English)

    GONG Mao-sheng; XIE Li-li

    2005-01-01

    Based on 266 strong ground motion records, an attenuation relationship was developed for both absolute and relative input energy spectra. The comparison of the two kinds of input energy spectra constructed from the attenuation relationship was made in this paper. The results show that there is little difference between the absolute input energy spectra and relative input energy spectra at the periods of 0.5~1.0 s for elastic systems and at the period of 0.5 s for inelastic systems. The absolute input energy spectra are much larger than relative input energy spectra in very short period range but some less than relative input energy spectra in long period range. It is also found that the ductility factor has a significant effect on both absolute and relafve input energy spectra. The absolute input energy spectra increase with the increasing of ductility factor in the period range of less than 0.3 s but decrease in the period range of larger than 0.3 s. The absolute input energy spectra for different ductility factor are almost equivalent at the period about 0.3 s, but for relative input energy spectra, the period is about 0.5 s. The effect of ductility on the relative input energy spectra in the short period range is much larger than that on the absolute input energy spectra, especially on the softer site class.

  17. Micro-Gal laser absolute gravimeter based on high precision heterodyne interferometer

    Institute of Scientific and Technical Information of China (English)

    Zhiping Zhang; Zhaogu Cheng; Zhaoyu Qin; Jianqiang Zhu

    2007-01-01

    A micro-Gal absolute gravimeter based on high-precision and high-stability heterodyne interferometer is presented. The distance measuring technology of the gravimeter is studied in detail. The experimental results of distance measuring for a free-falling motion show that the high-precision heterodyne interferometer described in this paper can meet the demand of a micro-Gal absolute gravimeter with relative uncertainty of 6.4 × 10-9. Moreover, the heterodyne interferometer is more stable than the Mach-Zehnder interferometer (MZI) which is widely used in present absolute gravimeters.

  18. Comparison of elicitation potential of chloroatranol and atranol--2 allergens in oak moss absolute

    DEFF Research Database (Denmark)

    Johansen, Jeanne D; Bernard, Guillaume; Giménez-Arnau, Elena;

    2006-01-01

    Chloroatranol and atranol are degradation products of chloroatranorin and atranorin, respectively, and have recently been identified as important contact allergens in the natural fragrance extract, oak moss absolute. Oak moss absolute is widely used in perfumery and is the cause of many cases...... sensitization to chloroatranol and oak moss absolute were tested simultaneously to a serial dilution of chloroatranol and atranol in ethanol, in equimolar concentrations (0.0034-1072 microM). Dose-response curves were estimated and analysed by logistic regression. The estimated difference in elicitation potency...

  19. The absolute gravity measurement by FG5 gravimeter at Great Wall Station, Antarctica

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Gravity measurement is of great importance to the height datum in Antarctica.The absolute gravity measurement was carried out at Great Wall Station, Antarctica, using FG5 absolute gravity instrument.The gravity data was processed with corrections of earth tide, ocean tide, polar motion and the atmospher, and the RMS is within +3 x 10 -s ms-2.The vertical and horizontal gravity gradients were measured using 2 LaCoaste & Romberg (LCR) gravimeters.The absolute gravity measurement provides the fundamental data for the validation and calibration of the satellite gravity projects such as CHAMP, GRACE and GOCE, and for the high accuracy geoid model.

  20. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    Science.gov (United States)

    Yoshikawa, M.; Okamoto, Y.; Kawamori, E.; Watanabe, Y.; Watabe, C.; Yamaguchi, N.; Tamano, T.

    2001-07-01

    A grazing incidence flat-field soft X-ray (20-350 Å) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  1. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    CERN Document Server

    Yoshikawa, M; Kawamori, E; Watanabe, Y; Watabe, C; Yamaguchi, N; Tamano, T

    2001-01-01

    A grazing incidence flat-field soft X-ray (20-350 A) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  2. The speed of light perturbation in absolute gravimeters from the viewpoint of ‘relativistic geometry’

    Science.gov (United States)

    Shao, Cheng-Gang; Tan, Yu-Jie; Li, Jia; Hu, Zhong-Kun

    2015-04-01

    In the past few years, the perturbation due to the finite speed of light was among the most inconsistent in corner-cube absolute gravimeters. For the relativistic treatment of the perturbation based on Lorentz transformation, the relation between Doppler shift in special relativity and time delay in classical domain is easily misunderstood, leading to spurious conclusions. To avoid these issues, we apply a ‘relativistic geometrical method’ based on the motion of photons to calculate the frequency shift in corner-cube absolute gravimeters, where the misunderstood relation has been corrected. Additionally, we find that the modern corner-cube absolute gravimeters cannot sense effects of the special relativity.

  3. Nonabsolute Fuzzy Integrals, Absolute Integrability and Its Absolute Value Inequality%非绝对模糊积分,绝对可积性与积分的绝对值不等式

    Institute of Scientific and Technical Information of China (English)

    巩增泰

    2008-01-01

    Absolute integrability and its absolute value inequality for fuzzy-number-valued functions are worth to be considered. In this paper, absolute integrability and its absolute valueine quality for fuzzy-number-valued functions are discussed by means of the characteristic theorems of nonabsolute fuzzy integrals and the embedding theorem, i.e., the fuzzy number space can be embedded into a concrete Banach space. Several necessary and sufficient conditions and examples are given.

  4. Sea Surface Height, Absolute, Aviso, 0.25 degrees, Global, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aviso Absolute Sea Surface Height is the Sea Surface Height Deviation plus the long term mean dynamic height. This is Science Quality data.

  5. Geomagnetic Absolute Mean Values at Hourly Intervals from 220 Observatories Worldwide

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This file is comprised of absolute mean hourly values of the geomagnetic components D, H and Z or X, Y and Z. These values, on magnetic tape, are available from...

  6. Absolute flatness testing of skip-flat interferometry by matrix analysis in polar coordinates.

    Science.gov (United States)

    Han, Zhi-Gang; Yin, Lu; Chen, Lei; Zhu, Ri-Hong

    2016-03-20

    A new method utilizing matrix analysis in polar coordinates has been presented for absolute testing of skip-flat interferometry. The retrieval of the absolute profile mainly includes three steps: (1) transform the wavefront maps of the two cavity measurements into data in polar coordinates; (2) retrieve the profile of the reflective flat in polar coordinates by matrix analysis; and (3) transform the profile of the reflective flat back into data in Cartesian coordinates and retrieve the profile of the sample. Simulation of synthetic surface data has been provided, showing the capability of the approach to achieve an accuracy of the order of 0.01 nm RMS. The absolute profile can be retrieved by a set of closed mathematical formulas without polynomial fitting of wavefront maps or the iterative evaluation of an error function, making the new method more efficient for absolute testing.

  7. Absolute Wavelength Control of Lasers for Active Sensing in Space Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop compact absolute wavelength references to weak molecular transitions, which is a challenge characteristic to space-based active sensing. The...

  8. The Interaction of Spatial Visualization and General Reasoning Abilities with Instructional Treatment on Absolute Value Equations

    Science.gov (United States)

    Eastman, Phillip M.; Salhab, Mohammed

    1978-01-01

    One group of elementary education majors received an algebraic instructional treatment of a unit on linear absolute value equations while another received a geometric treatment. The hypothesis of an aptitude-by-treatment interaction was statistically confirmed. (MN)

  9. Recent Progress in Liquid Scintillation Counting System for Absolute Radioactivity Measurement

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The triple to double coincidence ratio (TDCR) method is an absolute activity measurement method in liquid scintillation counting, especially developed for pure β- and EC-emitters activity standardization. Such a liquid scintillation counting system is now

  10. Combining Near-Subject Absolute and Relative Measures of Longitudinal Hydration in Hemodialysis

    OpenAIRE

    Chan, Cian; McIntyre, Christopher; Smith, David; Spanel, Patrik; Davies, Simon J.

    2009-01-01

    Background and objectives: The feasibility and additional value of combining bioimpedance analysis (BIA) with near-subject absolute measurement of total body water using deuterium dilution (TBWD) in determining longitudinal fluid status was investigated.

  11. On the absolute encoders%论绝对编码器

    Institute of Scientific and Technical Information of China (English)

    龚仲华

    2011-01-01

    This article illustrates the features of incremental encoder, resolver, absolute-value encoder, absolute encoder, grating encoder and magnetic grid encoder used on CNC machine tools, and their differences are explained as well, then points out the essence of the absolute rotary encoder and introduces the output method and interface for absolute positions.%说明了数控机床所使用的增量编码器、旋转变压器、绝对值编码器、绝对编码器以及光栅编码器与磁栅编码器的特点与区别,指出了绝对编码器的本质,介绍了绝对位置输出的方式与接口。

  12. Calculations of absolute intensities of γ-rays associated with (ε+β+) decay

    Institute of Scientific and Technical Information of China (English)

    ZHOU Chun-Mei; WU Zhen-Dong

    2005-01-01

    The calculation of absolute intensities of γ-rays arising from (ε+β+) decay is introduced briefly. Some examples are given to illustrate their applications. And some discussions are also made in the text.

  13. New archaeomagnetic data recovered from the study of celtiberic remains from central Spain (Numancia and Ciadueña, III-I BC).

    Science.gov (United States)

    Osete, María Luisa; Chauvin, Annick; Catanzariti, Gianluca; Jimeno, Alfredo; Campuzano, Saioa A.; Benito-Batanero, Juan Pedro; Roperch, Pierrick

    2016-04-01

    Variation of geomagnetic field changes in the Iberian Peninsula between prior to roman times remain very poorly constrained. Here we report results from the archeomagnetic study carried out on four set of ceramics and one combustion structure recovered in two pre-roman (celtiberic) archeological sites in central Spain. Rock magnetic experiments indicate the ChRM is carried by magnetite. Archaeointensity determinations were carried out by using the classical Thellier-Thellier experiment including tests and corrections for magnetic anisotropy and magnetic cooling rate dependency. Well heated specimens (red ceramic fragments and well heated samples from the kiln) show one single well defined component of magnetisation going through the origin and a linear arai plot providing successful archaeointensity determinations. The effect of anisotropy of the termoremanent magnetization (ATRM) on paleointensity analysis was specially investigated obtaining very high ATRM corrections on fine pottery specimens. With differences between the uncorrected and ATRM corrected paleointensity values that reached up to 80-100%. Mean intensity values obtained from three selected groups were 61.1 ±5.9μT; 57.6±3.3 and 56.4± 4.7μT which allows delineate the evolution of the paleofield intensity in central Iberia during the III-I centuries BC. The new archaeointensity data disagrees with previous results from Iberian ceramics which were not corrected by the ATRM effect. But they are in agreement with the most recent French paleointensity curve and latest European intensity model. Both based on a selection of high quality paleointensity data. This result reinforces the idea that the puzzling scatter often observed in the global paleointensity database is likely due to differences in the laboratory protocol. Further data from well contrasted laboratory protocols are still necessary to delineate confidently the evolution of the geomagnetic paleofield during the first millennium BC.

  14. Memory for musical tempo: Additional evidence that auditory memory is absolute

    OpenAIRE

    Levitin, Daniel J.; Cook, Perry R.

    1996-01-01

    We report evidence that long term memory retains absolute (accurate) features of perceptual events. Specifically, we show that memory for music seems to preserve the absolute tempo of the musical performance. In Experiment 1, 46 subjects sang popular songs from memory, and their tempos were compared to recorded versions of the songs. Seventy-two of the subjects came within 8% of the actual tempo on two consecutive trials (using different songs), demonstrating accuracy near the perceptual thre...

  15. Absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer

    OpenAIRE

    Hirano, Masahiro; Katoh, Munenori

    2015-01-01

    [Purpose] The aim of this study was to verify the absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD). [Subjects and Methods] The subjects were 33 healthy college students. The measurements were made three times with the HHD fixed using a belt (BFHHD) or with the examiner’s hand (conventional method; HFHHD). The absolute reliability of measurements was verified using Bland-Altman analysis, both in the all subjects group an...

  16. Absolute Calibration of the Radio Astronomy Flux Density Scale at 22 to 43 GHz Using Planck

    OpenAIRE

    B. Partridge; López-Caniego, M.; Perley, R. A.; Stevens, J.; Butler, B. J.; Rocha, G.; Walter, B; Zacchei, A.

    2015-01-01

    The Planck mission detected thousands of extragalactic radio sources at frequencies from 28 to 857 GHz. Planck's calibration is absolute (in the sense that it is based on the satellite's annual motion around the Sun and the temperature of the cosmic microwave background), and its beams are well characterized at sub-percent levels. Thus Planck's flux density measurements of compact sources are absolute in the same sense. We have made coordinated VLA and ATCA observations of 65 strong, unresolv...

  17. Quantifying Discipline Practices Using Absolute vs. Relative Frequencies: Clinical and Research Implications for Child Welfare

    OpenAIRE

    Lindhiem, Oliver; Shaffer, Anne; Kolko, David J.

    2013-01-01

    In the parent intervention outcome literatures, discipline practices are generally quantified as absolute frequencies or, less commonly, as relative frequencies. These differences in methodology warrant direct comparison as they have critical implications for study results and conclusions among treatments targeted at reducing parental aggression and harsh discipline. In this study, we directly compared the absolute frequency method and the relative frequency method for quantifying physically ...

  18. Michelson-Morley result, a Voigt-Doppler effect in absolute space-time

    Energy Technology Data Exchange (ETDEWEB)

    Wesley, J.P.

    1986-08-01

    Voigt's 1887 explanation of the Michelson-Morley result as a Doppler effect using absolute space-time is examined. It is shown that Doppler effects involve two wave velocities: (1) the phase velocity, which is used to account for the Michelson-Morley null result, and (2) the velocity of energy propagation, which, being fixed relative to absolute space, may be used to explain the results of Roemer, Bradley, Sagnac, Marinov, and the 2.7 degrees K anisotropy.

  19. Robust Absolute Stability of General Interval Lur'e Type Nonlinear Control Systems

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper, Lyapunov function method isused to study the robust absolute stability of general interval Lur'e type nonlinear control systems. As a result, algebraically sufficient conditions with interval matrix inequality form are obtained for the general interval Lur'e type nonlinear control systems, thus the relationship between the stability of symmetrical interval matrix and the robust absolute stability of general interval Lur'e type nonlinear control systems is established.

  20. Adaptive Pointing Design and Evaluation of a Precision Enhancing Technique for Absolute Pointing Devices

    OpenAIRE

    König, Werner A.; Gerken, Jens; Dierdorf, Stefan; Reiterer, Harald

    2009-01-01

    We present Adaptive Pointing, a novel approach to addressing the common problem of accuracy when using absolute pointing devices for distant interaction. First, we discuss extensively some related work concerning the problem-domain of pointing accuracy when using absolute or relative pointing devices. As a result, we introduce a novel classification scheme to more clearly discriminate between different approaches. Second, the Adaptive Pointing technique is presented and described in detail. ...

  1. The policy relevance of absolute and relative poverty headcounts: What's in a number?

    OpenAIRE

    Notten, Geranda; Chris DE NEUBOURG

    2007-01-01

    Financial poverty indicators still play an important role in policymaking and evaluation. Countries such as the USA and the EU member states use one or several ‘official’ poverty indicators on which success of poverty reduction policy is regularly monitored. Whereas the US poverty indicator is based on an absolute concept of poverty, the EU Laeken indicator is based on a relative concept. But the consequences of such a decision are considerable. As absolute and relative poverty indicators ref...

  2. Crystallization of an achiral cyclohexanone ethylene ketal in enantiomorphs and determination of the absolute structure.

    Science.gov (United States)

    Graus, Sara; Tejedor, Rosa M; Uriel, Santiago; Serrano, José Luis; Alkorta, Ibon; Elguero, José

    2010-06-16

    The achiral 4-methoxy-4-(p-methoxyphenyl)-cyclohexanone ethylene ketal (1) resolves spontaneously. The crystal structure is solved in chiral spatial group P2(1). Because compound 1 is composed of only light atoms (C, H, O) it is not possible to determine its absolute structure configuration. An efficient procedure for the absolute structure configuration determination of flexible molecules containing only light atoms is proposed, based on the combination of X-ray diffraction, solid-state VCD, and DFT calculations.

  3. Absolute oscillator strength densities below 100eV of N2

    Institute of Scientific and Technical Information of China (English)

    Sun Jian-Min; Zhong Zhi-Ping; Zhu Lin-Fan; Liu Xiao-Jing; Yuan Zhen-Sheng; Xu Ke-Zun

    2005-01-01

    The absolute optical oscillator strength density (OOSD) and generalized oscillator strength densities (GOSDs)below 100eV of N2 are determined with an incident electron energy of 2500eV and an energy resolution of 100 meV.The absolute generalized oscillator strengths (GOSs) for two transitions to the superexcited states at 23 and 31.4eV are determined and their momentum transfer dependence behaviours are discussed.

  4. Absolute Fluorescence Spectrum and Yield Measurements for a wide range of experimental conditions

    OpenAIRE

    Monnier Ragaigne, D.; Gorodetzky, P.; Moretto, C; Blaksley, C.; Dagoret-Campagne, D.; Gonnin, A.; Miyamoto, H.; Monard, H.; Wicek, F.

    2013-01-01

    For the JEM-EUSO Collaboration The fluorescence yield is a key ingredient in cosmic ray energy determination. It is sensitive to pressure, temperature and humidity. Up to now the fluorescence yield of the brightest line at 337 nm has been measured in an absolute way in one set of conditions, whereas fluorescence yields at the other wavelengths have been relatively measured for different conditions. Thus, absolute calibration for all the lines is unclear. We will do all measurements at once...

  5. Compatibility of the theory of special relativity with an absolute reference frame with a longitudinal Doppler shift

    OpenAIRE

    Sato, Masanori

    2006-01-01

    We show the compatibility of the theory of special relativity with the absolute reference frame with a longitudinal Doppler shift. Using two absolute velocities vA and vS, the relative velocity u is derived. Thereafter the Doppler frequency is derived using the relative velocity u. We also show the method for detecting the absolute reference frame. The representation of the theory of special relativity using the absolute reference frame appears more intuitive than an orthodox interpretation.

  6. RIESZ IDEMPOTENT AND BROWDER'S THEOREM FOR ABSOLUTE-(p, r)-PARANORMAL OPERATORS

    Institute of Scientific and Technical Information of China (English)

    Salah Mecheri

    2012-01-01

    An operator T is said to be paranormal if ||T2x|| ≥ ||Tx||2 holds for every unit vector x.Several extensions of paranormal operators are considered until now,for example absolute-k-paranormal and p-paranormal introduced in [10],[14],respectively.Yamazaki and Yanagida [38] introduced the class of absolute-(p,r)-paranormal operators as a further generalization of the classes of both absolute-k-paranormal and p-paranormal operators.An operator T ∈ B(H) is called absolute-(p,r)-paranormal operator if |||T|p|T*|rx||r ≥|||T*|rx||p+r for every unit vector x ∈ H and for positive real numbers p > 0 and r > 0.The famous result of Browder,that self adjoint operators satisfy Browder's theorem,is extended to several classes of operators.In this paper we show that for any absolute-(p,r)-paranormal operator T,T satisfies Browder's theorem and a-Browder's theorem.It is also shown that if E is the Riesz idempotent for a nonzero isolated point μ of the spectrum of a absolute-(p,r)-paranormal operator T,then E is self-adjoint if and only if the null space of T-μ,N(T-μ) (∪) N(T*-(-μ)).

  7. Absolute phase control of spectra effects in a two-level medium driven by two-color ultrashort laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Xia Keyu [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate University of Chinese Academy of Sciences (China); Niu Yueping [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate University of Chinese Academy of Sciences (China); Li Chunfang [Department of Physics, Shanghai University, Shanghai 200436 (China); Gong Shangqing [CCAST (World Laboratory), PO Box 8730, Beijing 100080 (China) and State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China)]. E-mail: sqgong@siom.ac.cn

    2007-01-22

    Using a {omega}-3{omega} combination scenario, we investigate the absolute phase control of the spectra effects for ultrashort laser pulses propagating in a two-level medium. It is found that the higher spectral components can be controlled by the absolute phases. In particular, different absolute phase combinations can lead to the buildup or split of the even harmonics.

  8. Application of the Absolute Nodal Co-Ordinate Formulation to Multibody System Dynamics

    Science.gov (United States)

    Escalona, J. L.; Hussien, H. A.; Shabana, A. A.

    1998-07-01

    The floating frame of reference formulation is currently the most widely used approach in flexible multibody simulations. The use of this approach, however, has been limited to small deformation problems. In this investigation, the computer implementation of the newabsolute nodal co-ordinate formulationand its use in the small and large deformation analysis of flexible multibody systems that consist of interconnected bodies are discussed. While in the floating frame of reference formulation a mixed set of absolute reference and local elastic co-ordinates are used, in the absolute nodal co-ordinate formulation only absolute co-ordinates are used. In the absolute nodal co-ordinate formulation, new interpretation of the nodal co-ordinates of the finite elements is used. No infinitesimal or finite rotations are used as nodal co-ordinates from beams and plates, instead, global slopes are used to define the element nodal co-ordinates. Using this interpretation of the element co-ordinates, beams and plates can be considered as isoparametric elements, and as a result, exact modelling of the rigid body dynamics can be obtained using the element shape function and the absolute nodal co-ordinates. Unlike the floating frame of reference approach, no co-ordinate transformation is required in order to determine the element inertia. The mass matrix of the finite elements is a constant matrix, and therefore, the centrifugal and Coriolis forces are equal to zero when the absolute nodal co-ordinate formulation is used. Another advantage of using the absolute nodal co-ordinate formulation in the dynamic simulation of multibody systems is its simplicity in imposing some of the joint constraints and also its simplicity in formulating the generalized forces due to spring-damper elements. The results obtained in this investigation show an excellent agreement with the results obtained using the floating frame of reference formulation when large rotation-small deformation problems are

  9. The Implications for Higher-Accuracy Absolute Measurements for NGS and its GRAV-D Project

    Science.gov (United States)

    Childers, V. A.; Winester, D.; Roman, D. R.; Eckl, M. C.; Smith, D. A.

    2013-12-01

    Absolute and relative gravity measurements play an important role in the work of NOAA's National Geodetic Survey (NGS). When NGS decided to replace the US national vertical datum, the Gravity for the Redefinition of the American Vertical Datum (GRAV-D) project added a new dimension to the NGS gravity program. Airborne gravity collection would complement existing satellite and surface gravity data to allow the creation of a gravimetric geoid sufficiently accurate to form the basis of the new reference surface. To provide absolute gravity ties for the airborne surveys, initially new FG5 absolute measurements were made at existing absolute stations and relative measurements were used to transfer those measurements to excenters near the absolute mark and to the aircraft sensor height at the parking space. In 2011, NGS obtained a field-capable A10 absolute gravimeter from Micro-g LaCoste which became the basis of the support of the airborne surveys. Now A10 measurements are made at the aircraft location and transferred to sensor height. Absolute and relative gravity play other roles in GRAV-D. Comparison of surface data with new airborne collection will highlight surface surveys with bias or tilt errors and can provide enough information to repair or discard the data. We expect that areas of problem surface data may be re-measured. The GRAV-D project also plans to monitor the geoid in regions of rapid change and update the vertical datum when appropriate. Geoid change can result from glacial isostatic adjustment (GIA), tectonic change, and the massive drawdown of large scale aquifers. The NGS plan for monitoring these changes over time is still in its preliminary stages and is expected to rely primarily on the GRACE and GRACE Follow On satellite data in conjunction with models of GIA and tectonic change. We expect to make absolute measurements in areas of rapid change in order to verify model predictions. With the opportunities presented by rapid, highly accurate

  10. A special application of absolute value techniques in authentic problem solving

    Science.gov (United States)

    Stupel, Moshe

    2013-06-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value expressions are involved, the definition that is most helpful is the one involving solving by intervals and evaluating critical points. In point of fact, application of this technique is one reason that the topic of absolute value is important in mathematics in general and in mathematics teaching in particular. We present here an authentic practical problem that is solved using absolute values and the 'intervals' method, after which the solution is generalized with surprising results. This authentic problem also lends itself to investigation using educational technological tools such as GeoGebra dynamic geometry software: mathematics teachers can allow their students to initially cope with the problem by working in an inductive environment in which they conduct virtual experiments until a solid conjecture has been reached, after which they should prove the conjecture deductively, using classic theoretical mathematical tools.

  11. Calibrating the absolute amplitude scale for air showers measured at LOFAR

    International Nuclear Information System (INIS)

    Air showers induced by cosmic rays create nanosecond pulses detectable at radio frequencies. These pulses have been measured successfully in the past few years at the LOw-Frequency ARray (LOFAR) and are used to study the properties of cosmic rays. For a complete understanding of this phenomenon and the underlying physical processes, an absolute calibration of the detecting antenna system is needed. We present three approaches that were used to check and improve the antenna model of LOFAR and to provide an absolute calibration of the whole system for air shower measurements. Two methods are based on calibrated reference sources and one on a calibration approach using the diffuse radio emission of the Galaxy, optimized for short data-sets. An accuracy of 19% in amplitude is reached. The absolute calibration is also compared to predictions from air shower simulations. These results are used to set an absolute energy scale for air shower measurements and can be used as a basis for an absolute scale for the measurement of astronomical transients with LOFAR

  12. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  13. Antiausterity activity of arctigenin enantiomers: importance of (2R,3R)-absolute configuration.

    Science.gov (United States)

    Awale, Suresh; Kato, Mamoru; Dibwe, Dya Fita; Li, Feng; Miyoshi, Chika; Esumi, Hiroyasu; Kadota, Shigetoshi; Tezuka, Yasuhiro

    2014-01-01

    From a MeOH extract of powdered roots of Wikstroemia indica, six dibenzyl-gamma-butyrolactone-type lignans with (2S,3S)-absolute configuration [(+)-arctigenin (1), (+)-matairesinol (2), (+)-trachelogenin (3), (+)-nortrachelogenin (4), (+)-hinokinin (5), and (+)-kusunokinin (6)] were isolated, whereas three dibenzyl-gamma-butyrolactone-type lignans with (2R,3R)-absolute configuration [(-)-arctigenin (1*), (-)-matairesinol (2*), (-)-trachelogenin (3*)] were isolated from Trachelospermum asiaticum. The in vitro preferential cytotoxic activity of the nine compounds was evaluated against human pancreatic PANC-1 cancer cells in nutrient-deprived medium (NDM), but none of the six lignans (1-6) with (2S,3S)-absolute configuration showed preferential cytotoxicity. On the other hand, three lignans (1*-3*) with (2R,3R)-absolute configuration exhibited preferential cytotoxicity in a concentration-dependent manner with PC50 values of 0.54, 6.82, and 5.85 microM, respectively. Furthermore, the effect of (-)- and (+)-arctigenin was evaluated against the activation of Akt, which is a key process in the tolerance to nutrition starvation. Interestingly, only (-)-arctigenin (1*) strongly suppressed the activation of Akt. These results indicate that the (2R,3R)-absolute configuration of (-)-enantiomers should be required for the preferential cytotoxicity through the inhibition of Akt activation. PMID:24660468

  14. Calibrating the absolute amplitude scale for air showers measured at LOFAR

    CERN Document Server

    Nelles, A; Karskens, T; Krause, M; Buitink, S; Corstanje, A; Enriquez, J E; Erdmann, M; Falcke, H; Haungs, A; Hiller, R; Huege, T; Krause, R; Link, K; Norden, M J; Rachen, J P; Rossetto, L; Schellart, P; Scholten, O; Schröder, F G; ter Veen, S; Thoudam, S; Trinh, T N G; Weidenhaupt, K; Wijnholds, S J; Anderson, J; Bähren, L; Bell, M E; Bentum, M J; Best, P; Bonafede, A; Bregman, J; Brouw, W N; Bruüggen, M; Butcher, H R; Carbone, D; Ciardi, B; de Gasperin, F; Duscha, S; Eislöffel, J; Fallows, R A; Frieswijk, W; Garrett, M A; van Haarlem, M P; Heald, G; Hoeft, M; Horneffer, A; Iacobelli, M; Juette, E; Karastergiou, A; Kohler, J; Kondratiev, V I; Kuniyoshi, M; Kuper, G; van Leeuwen, J; Maat, P; McFadden, R; McKay-Bukowski, D; Orru, E; Paas, H; Pandey-Pommier, M; Pandey, V N; Pizzo, R; Polatidis, A G; Reich, W; Röttgering, H; Schwarz, D; Serylak, M; Sluman, J; Smirnov, O; Tasse, C; Toribio, M C; Vermeulen, R; van Weeren, R J; Wijers, R A M J; Wucknitz, O; Zarka, P

    2015-01-01

    Air showers induced by cosmic rays create nanosecond pulses detectable at radio frequencies. These pulses have been measured successfully in the past few years at the LOw- Frequency ARray (LOFAR) and are used to study the properties of cosmic rays. For a complete understanding of this phenomenon and the underlying physical processes, an absolute calibration of the detecting antenna system is needed. We present three approaches that were used to check and improve the antenna model of LOFAR and to provide an absolute calibration for air shower measurements. Two methods are based on calibrated reference sources and one on a calibration approach using the diffuse radio emission of the Galaxy, optimized for short data-sets. An accuracy of 35% in amplitude is reached. The absolute calibration is also compared to predictions from air shower simulations. These results are used to set an absolute energy scale for air shower measurements and can be used as a basis for an absolute scale for the measurement of astronomic...

  15. Absolute Magnitude Calibration for Dwarfs Based on the Colour-Magnitude Diagrams of Galactic Clusters

    CERN Document Server

    Karaali, S; Bilir, S; Guctekin, S Tuncel

    2014-01-01

    We present two absolute magnitude calibrations for dwarfs based on colour-magnitude diagrams of Galactic clusters. The combination of the $M_g$ absolute magnitudes of the dwarf fiducial sequences of the clusters M92, M13, M5, NGC 2420, M67 and NGC 6791 with the corresponding metallicities provides absolute magnitude calibration for a given $(g-r)_0$ colour. The calibration is defined in the colour interval $0.25\\leq (g-r)_0 \\leq 1.25$ mag and it covers the metallicity interval $-2.15\\leq \\lbrack Fe/H\\rbrack \\leq +0.37$ dex. The absolute magnitude residuals obtained by the application of the procedure to another set of Galactic clusters lie in the interval $-0.15 \\leq \\Delta M_g \\leq +0.12$ mag. The mean and standard deviation of the residuals are $=-0.002$ and $\\sigma=0.065$ mag, respectively. The calibration of the $M_J$ absolute magnitude in terms of metallicity is carried out by using the fiducial sequences of the clusters M92, M13, 47 Tuc, NGC 2158 and NGC 6791. It is defined in the colour interval $0.90 ...

  16. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    Science.gov (United States)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  17. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  18. Comparison of elicitation potential of chloroatranol and atranol--2 allergens in oak moss absolute.

    Science.gov (United States)

    Johansen, Jeanne D; Bernard, Guillaume; Giménez-Arnau, Elena; Lepoittevin, Jean-Pierre; Bruze, Magnus; Andersen, Klaus E

    2006-04-01

    Chloroatranol and atranol are degradation products of chloroatranorin and atranorin, respectively, and have recently been identified as important contact allergens in the natural fragrance extract, oak moss absolute. Oak moss absolute is widely used in perfumery and is the cause of many cases of fragrance allergic contact dermatitis. Chloroatranol elicits reactions at very low levels of exposure. In oak moss absolute, chloroatranol and atranol are present together and both may contribute to the allergenicity and eliciting capacity of the natural extract. In this study, 10 eczema patients with known sensitization to chloroatranol and oak moss absolute were tested simultaneously to a serial dilution of chloroatranol and atranol in ethanol, in equimolar concentrations (0.0034-1072 microM). Dose-response curves were estimated and analysed by logistic regression. The estimated difference in elicitation potency of chloroatranol relative to atranol based on testing with equimolar concentrations was 217% (95% confidence interval 116-409%). Both substances elicited reactions at very low levels of exposure. It is concluded that the differences in elicitation capacity between the 2 substances are counterbalanced by exposure being greater to atranol than to chloroatranol and that both substances contribute to the clinical problems seen in oak moss absolute-sensitized individuals. PMID:16650093

  19. Viscous linear stability of axisymmetric low-density jets: Parameters influencing absolute instability

    Science.gov (United States)

    Srinivasan, V.; Hallberg, M. P.; Strykowski, P. J.

    2010-02-01

    Viscous linear stability calculations are presented for model low-density axisymmetric jet flows. Absolute growth transitions for the jet column mode are mapped out in a parametric space including velocity ratio, density ratio, Reynolds number, momentum thickness, and subtle differences between velocity and density profiles. Strictly speaking, the profiles used in most jet stability studies to date are only applicable to unity Prandtl numbers and zero pressure gradient flows—the present work relaxes this requirement. Results reveal how subtle differences between the velocity and density profiles generally used in jet stability theory can dramatically alter the absolute growth rate of the jet column mode in these low-density flows. The results suggest heating/cooling or mass diffusion at the outer nozzle surface can suppress absolute instability and potentially global instability in low-density jets.

  20. Absolute Hydration Free Energies of Ions, Ion-Water Clusters, and Quasi-chemical Theory

    CERN Document Server

    Asthagiri, D; Ashbaugh, H S; Pratt, Lawrence R.

    2003-01-01

    Experimental studies on ion-water clusters have provided insights into the microscopic aspects of hydration phenomena. One common view is that extending those experimental studies to larger cluster sizes would give the single ion absolute hydration free energies not obtainable by classical thermodynamic methods. This issue is reanalyzed in the context of recent computations and molecular theories on ion hydration, particularly considering the hydration of H$^+$, Li$^+$, Na$^+$, and HO$^-$ ions and thence the hydration of neutral ion pairs. The hydration free energies of neutral pairs computed here are in good agreement with experimental results, whereas the calculated absolute hydration free energies, and the excess chemical potentials, deviate consistently from some recently tabulated hydration free energies based on ion-water cluster data. We show how the single ion absolute hydration free energies are not separated from the potential of the phase in recent analyses of ion-water cluster data, even in the li...

  1. Standardizing Type Ia Supernova Absolute Magnitudes Using Gaussian Process Data Regression

    CERN Document Server

    Kim, A G; Aldering, G; Antilogus, P; Aragon, C; Bailey, S; Baltay, C; Bongard, S; Buton, C; Canto, A; Cellier-Holzem, F; Childress, M; Chotard, N; Copin, Y; Fakhouri, H K; Gangler, E; Guy, J; Kerschhaggl, M; Kowalski, M; Nordin, J; Nugent, P; Paech, K; Pain, R; Pécontal, E; Pereira, R; Perlmutter, S; Rabinowitz, D; Rigault, M; Runge, K; Saunders, C; Scalzo, R; Smadja, G; Tao, C; Weaver, B A; Wu, C

    2013-01-01

    We present a novel class of models for Type Ia supernova time-evolving spectral energy distributions (SED) and absolute magnitudes: they are each modeled as stochastic functions described by Gaussian processes. The values of the SED and absolute magnitudes are defined through well-defined regression prescriptions, so that data directly inform the models. As a proof of concept, we implement a model for synthetic photometry built from the spectrophotometric time series from the Nearby Supernova Factory. Absolute magnitudes at peak $B$ brightness are calibrated to 0.13 mag in the $g$-band and to as low as 0.09 mag in the $z=0.25$ blueshifted $i$-band, where the dispersion includes contributions from measurement uncertainties and peculiar velocities. The methodology can be applied to spectrophotometric time series of supernovae that span a range of redshifts to simultaneously standardize supernovae together with fitting cosmological parameters.

  2. Do absolutely irreducible group actions have odd dimensional fixed point spaces?

    CERN Document Server

    Lauterbach, Reiner

    2010-01-01

    In his volume [5] on "Symmetry Breaking for Compact Lie Groups" Mike Field quotes a private communication by Jorge Ize claiming that any bifurcation problem with absolutely irreducible group action would lead to bifurcation of steady states. The proof should come from the fact that any absolutely irreducible representation possesses an odd dimensional fixed point space. In this paper we show that there are many examples of groups which have absolutely irreducible representations but no odd dimensional fixed point space. This observation may be relevant also for some degree theoretic considerations concerning equivariant bifurcation. Moreover we show that our examples give rise to some interesting Hamiltonian dynamics and we show that despite some complications we can go a long way towards doing explicit computations and providing complete proofs. For some of the invariant theory needed we will depend on some computer aided computations. The work presented here greatly benefited from the computer algebra progr...

  3. Chiral liquid chromatography contribution to the determination of the absolute configuration of enantiomers.

    Science.gov (United States)

    Roussel, Christian; Del Rio, Alberto; Pierrot-Sanders, Johanna; Piras, Patrick; Vanthuyne, Nicolas

    2004-05-28

    The review covers examples in which chiral HPLC, as a source of pure enantiomers, has been combined with classical methods (X-ray, vibrational circular dichroism (VCD), enzymatic resolutions, nuclear magnetic resonance (NMR) techniques, optical rotation, circular dichroism (CD)) for the on- or off-line determination of absolute configuration of enantiomers. Furthermore, it is outlined that chiral HPLC, which associates enantioseparation process and classical purification process, opens new perspectives in the classical determination of absolute configuration by chemical correlation or chemical interconversion methods. The review also contains a discussion about the various approaches to predict the absolute configuration from the retention behavior of the enantiomers on chiral stationary phases (CSPs). Some examples illustrate the advantages and limitations of molecular modeling methods and the use of chiral recognition models. The assumptions underlying some of these methods are critically analyzed and some possible emerging new strategies are outlined. PMID:15214673

  4. Fuzzy logic based anaesthesia monitoring systems for the detection of absolute hypovolaemia.

    Science.gov (United States)

    Mansoor Baig, Mirza; Gholamhosseini, Hamid; Harrison, Michael J

    2013-07-01

    Anaesthesia monitoring involves critical diagnostic tasks carried out amongst lots of distractions. Computers are capable of handling large amounts of data at high speed and therefore decision support systems and expert systems are now capable of processing many signals simultaneously in real time. We have developed two fuzzy logic based anaesthesia monitoring systems; a real time smart anaesthesia alarm system (RT-SAAM) and fuzzy logic monitoring system-2 (FLMS-2), an updated version of FLMS for the detection of absolute hypovolaemia. This paper presents the design aspects of these two systems which employ fuzzy logic techniques to detect absolute hypovolaemia, and compares their performances in terms of usability and acceptability. The interpretation of these two systems of absolute hypovolaemia was compared with clinicians' assessments using Kappa analysis, RT-SAAM K=0.62, FLMS-2 K=0.75; an improvement in performance by FLMS-2.

  5. The Absolute Vector Magnetometers on Board Swarm, Lessons Learned From Two Years in Space.

    Science.gov (United States)

    Hulot, G.; Leger, J. M.; Vigneron, P.; Brocco, L.; Olsen, N.; Jager, T.; Bertrand, F.; Fratter, I.; Sirol, O.; Lalanne, X.

    2015-12-01

    ESA's Swarm satellites carry 4He absolute magnetometers (ASM), designed by CEA-Léti and developed in partnership with CNES. These instruments are the first-ever space-born magnetometers to use a common sensor to simultaneously deliver 1Hz independent absolute scalar and vector readings of the magnetic field. They have provided the very high accuracy scalar field data nominally required by the mission (for both science and calibration purposes, since each satellite also carries a low noise high frequency fluxgate magnetometer designed by DTU), but also very useful experimental absolute vector data. In this presentation, we will report on the status of the instruments, as well as on the various tests and investigations carried out using these experimental data since launch in November 2013. In particular, we will illustrate the advantages of flying ASM instruments on space-born magnetic missions for nominal data quality checks, geomagnetic field modeling and science objectives.

  6. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  7. Measurement of absolute optical thickness of mask glass by wavelength-tuning Fourier analysis.

    Science.gov (United States)

    Kim, Yangjin; Hbino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2015-07-01

    Optical thickness is a fundamental characteristic of an optical component. A measurement method combining discrete Fourier-transform (DFT) analysis and a phase-shifting technique gives an appropriate value for the absolute optical thickness of a transparent plate. However, there is a systematic error caused by the nonlinearity of the phase-shifting technique. In this research the absolute optical-thickness distribution of mask blank glass was measured using DFT and wavelength-tuning Fizeau interferometry without using sensitive phase-shifting techniques. The error occurring during the DFT analysis was compensated for by using the unwrapping correlation. The experimental results indicated that the absolute optical thickness of mask glass was measured with an accuracy of 5 nm.

  8. Physical Measure and Absolute Continuity for One-Dimensional Center Direction

    CERN Document Server

    Viana, Marcelo

    2010-01-01

    For a class of partially hyperbolic $C^k$, $k>1$ diffeomorphisms with circle center leaves we prove existence and finiteness of physical (or Sinai-Ruelle-Bowen) measures, whose basins cover a full Lebesgue measure subset of the ambient manifold. Our conditions contain an open and dense subset of all $C^k$ partially hyperbolic skew-products on compact circle bundles. Our arguments blend ideas from the theory of Gibbs states for diffeomorphisms with mostly contracting center direction together with recent progress in the theory of cocycles over hyperbolic systems that call into play geometric properties of invariant foliations such as absolute continuity. Recent results show that absolute continuity of the center foliation is often a rigid property among volume preserving systems. We prove that this is not at all the case in the dissipative setting, where absolute continuity can even be robust.

  9. Absolute scaling law for temperature data in Rayleigh-Benard convection

    Institute of Scientific and Technical Information of China (English)

    FU Qiang

    2009-01-01

    In addition to the hierarchical-structure (H-S) model, this paper further explores the most intensive in-With respect to the discovery and by means of the scale, both of Bolgiano, there are two regions of the structure holding the absolute scaling law given by Ching's paper. Through theoretic analysis of data, this paper indicates that the regions act as two local intensive intermittent structures, by which the statistical absolute scaling performance of region is induced, rather than the statistical result of the entire time series in belief since 1941. In terms of statistical theory, the local structure in fluid, therefore, is the essence governing the absolute scaling performance of region, especially in high intensity.

  10. Absolute scaling law for temperature data in Rayleigh-Benard convection

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In addition to the hierarchical-structure (H-S) model, this paper further explores the most intensive intermittent structure of Rayleigh-Bénard convection at the high Ra numbers proportional to temperature. With respect to the discovery and by means of the scale, both of Bolgiano, there are two regions of the structure holding the absolute scaling law given by Ching’s paper. Through theoretic analysis of data, this paper indicates that the regions act as two local intensive intermittent structures, by which the statistical absolute scaling performance of region is induced, rather than the statistical result of the entire time series in belief since 1941. In terms of statistical theory, the local structure in fluid, therefore, is the essence governing the absolute scaling performance of region, especially in high intensity.

  11. Ridge-spotting: A new test for Pacific absolute plate motion models

    Science.gov (United States)

    Wessel, Paul; Müller, R. Dietmar

    2016-06-01

    Relative plate motions provide high-resolution descriptions of motions of plates relative to other plates. Yet geodynamically, motions of plates relative to the mantle are required since such motions can be attributed to forces (e.g., slab pull and ridge push) acting upon the plates. Various reference frames have been proposed, such as the hot spot reference frame, to link plate motions to a mantle framework. Unfortunately, both accuracy and precision of absolute plate motion models lag behind those of relative plate motion models. Consequently, it is paramount to use relative plate motions in improving our understanding of absolute plate motions. A new technique called "ridge-spotting" combines absolute and relative plate motions and examines the viability of proposed absolute plate motion models. We test the method on six published Pacific absolute plate motions models, including fixed and moving hot spot models as well as a geodynamically derived model. Ridge-spotting reconstructs the Pacific-Farallon and Pacific-Antarctica ridge systems over the last 80 Myr. All six absolute plate motion models predict large amounts of northward migration and monotonic clockwise rotation for the Pacific-Farallon ridge. A geodynamic implication of our ridge migration predictions is that the suggestion that the Pacific-Farallon ridge may have been pinned by a large mantle upwelling is not supported. Unexpected or erratic ridge behaviors may be tied to limitations in the models themselves or (for Indo-Atlantic models) discrepancies in the plate circuits used to project models into the Pacific realm. Ridge-spotting is promising and will be extended to include more plates and other ocean basins.

  12. Comparative study of sclerotherapy of venous malformation in children using absolute ethanol and pingyangmycin

    International Nuclear Information System (INIS)

    Objective: To evaluate and compare the curative effect and the safety of sclerotherapy of venous malformation in children using absolute ethanol and pingyangmycin. Methods: Eighty children with venous malformation were treated by sclerotherapy with absolute ethanol or pingyangmycin under general anesthesia during February of 2009 to May of 2011. Diagnostic criteria included the presence of a blue-colored lesion at birth, with gradual increase in its size associated with a positive postural test. MRI showed characteristic imaging features. Eighty patients were divided into two groups by randomization. Forty patients were treated with absolute ethanol, and the remaining 40 patients with pingyangmycin. The therapeutic effects and side effects were observed and recorded during a follow-up period of 6 to 24 months (average 15 months). Treatment results were divided into four categories: cure, basic cure, effective, and ineffective, and the former three categories were considered effective in treatment. Chi-square test was used to compare the rate of effective treatment and rate of complications in these two groups. Results: The effective patients treated with absolute ethanol was 38 (95.0%, 38/40), and the effective patients with pingyangmycin was 26 (65.0%, 26/40), χ2 test (χ2=11.25, P<0.01) difference was statistically significant. Eight patients developed skin necrosis; 4 patients serious local swelling, 2 patients muscle fibrosis, 1 patient cerebral embolism in the absolute alcohol group. Two patients developed postoperative fever and vomiting and 2 skin necrosis in the pingyangmycin group,the difference was statistically significant (χ2=12.29, P<0.01). Conclusions: Sclerotherapy is effective for the treatment of venous malformations in children. Absolute ethanol is more effective, but associated with more complications, such as skin necrosis or as serious as cerebral embolism, than pingyangmycin. (authors)

  13. Management of High Blood Pressure in Those without Overt Cardiovascular Disease Utilising Absolute Risk Scores

    Directory of Open Access Journals (Sweden)

    Mark R. Nelson

    2011-01-01

    Full Text Available Increasing blood pressure has a continuum of adverse risk for cardiovascular events. Traditionally this single measure was used to determine who to treat and how vigorously. However, estimating absolute risk rather than measurement of a single risk factor such as blood pressure is a superior method to identify who is most at risk of having an adverse cardiovascular event such as stroke or myocardial infarction, and therefore who would most likely benefit from therapeutic intervention. Cardiovascular disease (CVD risk calculators must be used to estimate absolute risk in those without overt CVD as physician estimation is unreliable. Incorporation into usual practice and limitations of the strategy are discussed.

  14. Absolute timing with IBIS, SPI and JEM-X aboard INTEGRAL

    OpenAIRE

    Kuiper, L.; Hermsen, W.; Walter, R.; Foschini, L.

    2003-01-01

    We have verified the absolute timing capabilities of the high-energy instruments aboard INTEGRAL, i.e. the imager IBIS, the spectrometer SPI and the X-ray monitor JEM-X. Calibration observations of the Crab, contemporaneous with the Rossi X-ray Timing Explorer (RXTE), have been used to measure the absolute phase of the main pulse of the Crab pulse profile using the same Jodrell Bank radio ephemeris. The three INTEGRAL instruments and RXTE give within the statistical and systematic uncertainti...

  15. Determination of the absolute configuration of sialic acids in gangliosides from the sea cucumber Cucumaria echinata.

    Science.gov (United States)

    Kisa, Fumiaki; Yamada, Koji; Miyamoto, Tomofumi; Inagaki, Masanori; Higuchi, Ryuichi

    2007-07-01

    Enantiomeric pairs of sialic acid, D- and L-NeuAc (N-acetylneuraminic acid), were converted to D- and L-arabinose, respectively, by chemical degradation. Using this method, the absolute configuration of the sialic acid residues, NeuAc and NeuGc (N-glycolylneuraminic acid), in the gangliosides from the sea cucumber Cucumaria echinata was determined to be the D-form. Although naturally occurring sialic acids have been believed to be the D-form on the basis of biosynthetic evidence, this is the first report of the determination of the absolute configuration of the sialic acid residues in gangliosides using chemical methods. PMID:17603199

  16. Research on a novel orientation algorithm of single-ring absolute photoelectric shaft encoder

    Institute of Scientific and Technical Information of China (English)

    CHEN Yun

    2007-01-01

    A novel single-ring absolute optical shaft encoder is designed by studying the encoding principle of traditional absolute optical shaft encoder in this paper. The description of the orientation algorithm of the encoder is specified,and an example for explaining the orientation arithmetic is given,which indicates that the theory of the encoder works. The visual interface to acquire signals of CCD is shown with VB,which provides reliable foundation to process data. The effective factors of measurement precision of the encoder are analyzed.

  17. Metrological activity determination of {sup 133}Ba by sum-peak absolute method

    Energy Technology Data Exchange (ETDEWEB)

    Silva, R.L. da; Delgado, J.U.; Poledna, R.; Santos, A.; Veras, E.V. de; Rangel, J.; Trindade, O.L. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.br, E-mail: candida@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not. The activity is obtained directly with good accuracy and low uncertainties. {sup 133}Ba is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods do not calibrate {sup 133}Ba due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes {sup 133}Ba samples. Uncertainties lower than 1% to activity results were obtained.

  18. Absolute UV absorption cross sections of dimethyl substituted Criegee intermediate (CH3)2COO

    Science.gov (United States)

    Chang, Yuan-Pin; Chang, Chun-Hung; Takahashi, Kaito; Lin, Jim-Min, Jr.

    2016-06-01

    The absolute absorption cross sections of (CH3)2COO under a jet-cooled condition were measured via laser depletion to be (1.32 ± 0.10) × 10-17 cm2 molecule-1 at 308 nm and (9.6 ± 0.8) × 10-18 cm2 molecule-1 at 352 nm. The peak UV cross section is estimated to be (1.75 ± 0.14) × 10-17 cm2 molecule-1 at 330 nm, according to the UV spectrum of (CH3)2COO (Huang et al., 2015) scaled to the absolute cross section at 308 nm.

  19. Density modulation-induced absolute laser-plasma-instabilities: simulations and theory

    CERN Document Server

    Li, J; Ren, C

    2016-01-01

    Fluid simulations show that when a sinusoidal density modulation is superimposed on a linear density profile, convective instabilities can become absolutely unstable. This conversion can occur for two-plasmon-decay and stimulated Raman Scattering instabilities under realistic direct-drive inertial confinement fusion conditions and can affect hot electron generation and laser energy deposition. Analysis of the three-wave model shows that a sufficiently large change of the density gradient in a linear density profile can turn convective instabilities into absolute ones. An analytical expression is given for the threshold of the gradient change, which depends on the convective gain only.

  20. Re-creating Gauss's method for non-electrical absolute measurements of magnetic fields and moments

    Science.gov (United States)

    Van Baak, D. A.

    2013-10-01

    In 1832, Gauss made the first absolute measurements of magnetic fields and of magnetic moments in experiments that are straightforward and instructive to replicate. We show, using rare-earth permanent magnets and a variation of Gauss's technique, that the horizontal component of the ambient geomagnetic field, as well as the size of the magnetic moments of such magnets, can be found. The method shows the connection between the SI and cgs emu unit systems for these quantities and permits an absolute realization of the Ampere with considerable precision.

  1. Metrological activity determination of 133Ba by sum-peak absolute method

    Science.gov (United States)

    da Silva, R. L.; de Almeida, M. C. M.; Delgado, J. U.; Poledna, R.; Santos, A.; de Veras, E. V.; Rangel, J.; Trindade, O. L.

    2016-07-01

    The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not. The activity is obtained directly with good accuracy and low uncertainties. 133Ba is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods don't calibrate 133Ba due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes 133Ba samples. Uncertainties lower than 1% to activity results were obtained.

  2. Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

    Science.gov (United States)

    Foukal, Peter V.; Hoyt, C.; Kochling, H.; Miller, P.

    1990-01-01

    The dramatic improvement in heat diffusivity of pure Cu at liquid-He temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table-top cryogenic ESR now available for detector calibration work to the 0.01-percent level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently delivered to the NIST for radiometric calibrations of black bodies is also described, along with the design and testing of a very fast cryogenic ESR developed for NASA remote-sensing studies of the earth's radiation budget.

  3. Application of fine absolute rated filters to PWR CVCS and radwaste filter duties

    International Nuclear Information System (INIS)

    Filters for PWR systems have generally been specified in terms of nominal removal ratings. Products supplied by different manufacturers against these specifications vary considerably in removal efficiency and service life. The paper describes the method used by Pall Corporation for reliable, reproducible assessment of filter performance and determination of absolute filtration ratings. The old nominal specifications are shown to be too coarse for effective removal of particle borne activity. The introduction into service of new absolute rated fine filter media with positive zeta potential is described. (author)

  4. Absolute γ-ray line intensities in mass chains A=142-144, 146 and 147

    International Nuclear Information System (INIS)

    Unknown absolute γ-ray line intensities of the members (cesium, barium, lanthanum, cerium) in mass chains 142, 143, 144, 146 and 147 were determined relative to the absolute γ-ray line intensities of the well known descendants 142La, 143Ce, 144La, 146Pr and 147Pr using the mass separators HELIOS and OSTIS. The method relies on a clean chemical separation of the first chain members of interest (cesium and barium) from their daughters that takes place in the ion source of the separators. (orig.)

  5. Absolute frequency measurement of the 1S0 - 3P0 transition of 171Yb

    CERN Document Server

    Pizzocaro, Marco; Rauf, Benjamin; Bregolin, Filippo; Milani, Gianmaria; Clivati, Cecilia; Costanzo, Giovanni A; Levi, Filippo; Calonico, Davide

    2016-01-01

    We report the absolute frequency measurement of the unperturbed transition 1S0 - 3P0 at 578 nm in 171Yb realized in an optical lattice frequency standard. The absolute frequency is measured 518 295 836 590 863.55(28) Hz relative to a cryogenic caesium fountain with a fractional uncertainty of 5.4x10-16 . This value is in agreement with the ytterbium frequency recommended as a secondary representation of the second in the International System of Units.

  6. Evaluation of absolute phase for 3D profile measurement using fringe projection

    Institute of Scientific and Technical Information of China (English)

    Mengtao Huang; Zhuangde Jiang; Bing Li; Suping Fang

    2006-01-01

    A new method of absolute phase evaluation for three-dimensional (3D) profile measurement using fringe projection is presented, which combines the gray code and the phase shift technique. Two kinds of fringe patterns are projected onto the object surface respectively, one is sinusoidal intensity distribution used for phase demodulation and the other is gray code fringe pattern for unwrapping. These images are acquired by camera and stored into computer. The absolute phase is obtained by analyzing these images. The validity of this method is verified experimentally. The method is superior to other phase unwrapping methods.

  7. A highly accurate absolute gravimetric network for Albania, Kosovo and Montenegro

    Science.gov (United States)

    Ullrich, Christian; Ruess, Diethard; Butta, Hubert; Qirko, Kristaq; Pavicevic, Bozidar; Murat, Meha

    2016-04-01

    The objective of this project is to establish a basic gravity network in Albania, Kosovo and Montenegro to enable further investigations in geodetic and geophysical issues. Therefore the first time in history absolute gravity measurements were performed in these countries. The Norwegian mapping authority Kartverket is assisting the national mapping authorities in Kosovo (KCA) (Kosovo Cadastral Agency - Agjencia Kadastrale e Kosovës), Albania (ASIG) (Autoriteti Shtetëror i Informacionit Gjeohapësinor) and in Montenegro (REA) (Real Estate Administration of Montenegro - Uprava za nekretnine Crne Gore) in improving the geodetic frameworks. The gravity measurements are funded by Kartverket. The absolute gravimetric measurements were performed from BEV (Federal Office of Metrology and Surveying) with the absolute gravimeter FG5-242. As a national metrology institute (NMI) the Metrology Service of the BEV maintains the national standards for the realisation of the legal units of measurement and ensures their international equivalence and recognition. Laser and clock of the absolute gravimeter were calibrated before and after the measurements. The absolute gravimetric survey was carried out from September to October 2015. Finally all 8 scheduled stations were successfully measured: there are three stations located in Montenegro, two stations in Kosovo and three stations in Albania. The stations are distributed over the countries to establish a gravity network for each country. The vertical gradients were measured at all 8 stations with the relative gravimeter Scintrex CG5. The high class quality of some absolute gravity stations can be used for gravity monitoring activities in future. The measurement uncertainties of the absolute gravity measurements range around 2.5 micro Gal at all stations (1 microgal = 10-8 m/s2). In Montenegro the large gravity difference of 200 MilliGal between station Zabljak and Podgorica can be even used for calibration of relative gravimeters

  8. A Novel Approach for Video-Based Absolute Navigation in Space Exploration Missions

    Science.gov (United States)

    Tadewos, Tadewos Getahun; Prinetto, Paolo; Rolfo, Daniele; Trotta, Pascal; Lanza, Piergiorgio; Martelli, Andrea; Tramutola, Antonio

    2014-08-01

    In the last years, Video-based Navigation is becoming an hot topic since camera sensors will be more and more included in future space exploration missions, to allow a visual comprehension of the surrounding unknown environment. This paper proposes a novel approach for Video-based Absolute Navigation focusing on the Entry, Descent and Landing phase of spacecrafts on planets. Moreover the paper shows how a Video-based Absolute Navigation processing chain can exploit Field Programmable Gate Array (FPGA) devices to achieve high throughput, in terms of frames-per-seconds. Experimental results highlight the robustness and limited memory requirements of the proposed approach.

  9. Existing conditions of full bandgaps and absolute negative refraction in metallic-dielectric photonic crystal

    Institute of Scientific and Technical Information of China (English)

    Dong Jian-Wen; Hu Xin-Hua; Wang He-Zhou

    2007-01-01

    This paper has theoretically studied the characteristic frequencies of band structures in two-dimensional metallicdielectric photonic crystals. It is demonstrated that a large filling fraction benefits the existence of absolute photonic band gap, while a smaller filling fraction benefits an absolute negative refraction band. In addition, it also finds that the relation between the cut-off frequency of E-polarized wave and the filling fraction exceeding 10% is content with a linear increasing function, whose coefficients are exponential to the normalized lattice constant. These investigations have significant implications for tuning the operational frequencies to desired applications and manufacturing photonic crystals.

  10. Absolutely Maximally Entangled states, combinatorial designs and multi-unitary matrices

    CERN Document Server

    Goyeneche, Dardo; Latorre, José I; Riera, Arnau; Życzkowski, Karol

    2015-01-01

    Absolutely Maximally Entangled (AME) states are those multipartite quantum states that carry absolute maximum entanglement in all possible partitions. AME states are known to play a relevant role in multipartite teleportation, in quantum secret sharing and they provide the basis novel tensor networks related to holography. We present alternative constructions of AME states and show their link with combinatorial designs. We also analyze a key property of AME, namely their relation to tensors that can be understood as unitary transformations in every of its bi-partitions. We call this property multi-unitarity.

  11. Observing gravity change in the Fennoscandian uplift area with the Hanover absolute gravimeter

    OpenAIRE

    Timmen, L.; Gitlein, O.; Volker Klemann; Wolf, D

    2012-01-01

    The Nordic countries Norway, Sweden, Finland and Denmark are a key study region for research of glacial isostasy. In addition, such research offers a unique opportunity for absolute gravimetry to show its capability as a geodetic tool for geophysical research. Within a multi-national cooperation, annual absolute gravity measurements have been performed in Fennoscandia by IfE since 2003. For the Hanover gravimeter FG5-220, overall accuracy of ±30 nm/s2 is indicated for a single station determi...

  12. Absolutely Fabulous!

    DEFF Research Database (Denmark)

    Hjorth, Daniel

    2013-01-01

    self-constitutive res cogitans (thinking thing or mind) will take priority over subjectification, and the paper will loose the possibility to think and study the process of becoming-subject in its own terms. Originality/value – Understanding entrepreneurship as organisation-creation, the paper here...

  13. Absolutely Chinese

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    <正>Ink painting animation - an exquisite art form that ends up in a museum Little Tadpole Looking for Mummy Little Tadpole Looking for Mummy, China’s first ink painting animation, was produced in 1961. With innovation in painting, photography and production technology, it was the first effort at ’animating’ ink paintings. Fishes, shrimps, frogs and crabs in the film resemble those in Qi Baishi’s works. By any shot, it’s an animated painting of fishes and insects, one that is suffused with a taste of Chinese ink-and-wash painting.

  14. Absolut sang

    DEFF Research Database (Denmark)

    Parly, Nila Charlotte

    En række analytiske gennemgange af de kvindelige hovedpartier i Richard Wagners værker fra "Den flyvende Hollænder" til "Parsifal". Med afsæt i Carl Dahlhaus' og Carolyn Abbates teorier fokuseres der på orkester- og sangstemmernes klanglige og melodiske betydning for værkernes komplekse dramaturg...

  15. Transitional directions from Early Miocene Lavas at Samothraki Island, N. Greece

    Science.gov (United States)

    Kondopoulou, Despina; Valet, Jean-Pierre; Zananiri, Irene; Voidomatis, Philippos

    2014-05-01

    The North Hellenic orogen was formed at the expenses of the Variscan and Jurassic oceanic crust, preserved in scattered ophiolitic massifs. Strong post-orogenic extension with coeval emplacement of granodioritic plutons, deposition of clastic sediments and calc-alkaline volcanism appeared from the Middle-Late Eocene to the Middle Miocene. These widespread Tertiary volcanic products, outcropping also in north and central Aegean, have been extensively studied as far as their emplacement conditions are concerned. In parallel, they have been the object of several palaeomagnetic studies, all consistently indicating a general pattern of clockwise rotations. The island of Samothraki belongs to the Circum-Rhodope Zone, a series of Triassic-Jurassic continental margin sedimentary and volcanic rocks that surround the crystalline Serbo-Macedonian and Rhodope Massifs. The geochronological data, along with the morphology and the eruption mode of the Samothraki Tertiary volcanic rocks, allow a division into three groups, namely the "old", the "intermediate" and the "young" ones. Several radiometric ages have been assigned to the three groups, spanning from 25 to 19 Ma. Isotope and trace-element modeling do not favor a continuous evolution of these magmas. The major granitic and volcanic formations of the island have been subjected to paleomagnetic studies. The results revealed a complex pattern with coexisting straightforward directions and puzzling ones, only within the younger lavas, mostly domes. These samples are characterized by a medium temperature component with an eastward declination and a positive inclination and a high temperature one with a negative inclination. Experiments of absolute paleointensity have been conducted on twenty-eight samples from 3 separate domes with ages between 22-19 Ma using a modified Thellier technique with very narrow 4°C to 10°C temperature steps between 500°C and 595°C. The results indicate significantly low field values at two sites

  16. No Absolutism Here: Harm Predicts Moral Judgment 30× Better Than Disgust-Commentary on Scott, Inbar, & Rozin (2016).

    Science.gov (United States)

    Gray, Kurt; Schein, Chelsea

    2016-05-01

    Moral absolutism is the idea that people's moral judgments are insensitive to considerations of harm. Scott, Inbar, and Rozin (2016, this issue) claim that most moral opponents to genetically modified organisms are absolutely opposed-motivated by disgust and not harm. Yet there is no evidence for moral absolutism in their data. Perceived risk/harm is the most significant predictor of moral judgments for "absolutists," accounting for 30 times more variance than disgust. Reanalyses suggest that disgust is not even a significant predictor of the moral judgments of absolutists once accounting for perceived harm and anger. Instead of revealing actual moral absolutism, Scott et al. find only empty absolutism: hypothetical, forecasted, self-reported moral absolutism. Strikingly, the moral judgments of so-called absolutists are somewhat more sensitive to consequentialist concerns than those of nonabsolutists. Mediation reanalyses reveal that moral judgments are most proximally predicted by harm and not disgust, consistent with dyadic morality. PMID:27217244

  17. Demonstrating the Error Budget for the Climate Absolute Radiance and Refractivity Observatory Through Solar Irradiance Measurements

    Science.gov (United States)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2016-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe highaccuracy, long-term climate change trends and to use decadal change observations as a method to determine the accuracy of climate change. A CLARREO objective is to improve the accuracy of SI-traceable, absolute calibration at infrared and reflected solar wavelengths to reach on-orbit accuracies required to allow climate change observations to survive data gaps and observe climate change at the limit of natural variability. Such an effort will also demonstrate National Institute of Standards and Technology (NIST) approaches for use in future spaceborne instruments. The current work describes the results of laboratory and field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. SOLARIS allows testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. Results of laboratory calibration measurements are provided to demonstrate key assumptions about instrument behavior that are needed to achieve CLARREO's climate measurement requirements. Absolute radiometric response is determined using laser-based calibration sources and applied to direct solar views for comparison with accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

  18. Low geometry counter for the absolute measurement of the activity of alpha-emitting sources

    International Nuclear Information System (INIS)

    A low-geometry counter is described which allows the absolute determination of the activity for alpha-emitting sources. A Si implanted detector is used to obtain the spectrum of the sample. Two samples are measured with this counter and a 2 π gridded ion chamber. The results an their uncertainties for both instruments are discussed. (Author)

  19. SUNCT syndrome responding absolutely to steroids in two cases with different etiologies

    OpenAIRE

    de Lourdes Figuerola, María; Bruera, Osvaldo; Pozzo, María Josefina; Leston, Jorge

    2008-01-01

    SUNCT is a syndrome of short-lasting unilateral neuralgiform headache attacks with conjunctival injection and tearing. We are presenting now two cases absolutely responders to steroid therapy, one of them a SUNCT-like secondary to a prolactinoma and the other primary.

  20. Measurement of the Absolute Proton and Helium Flux at the Top of the Atmosphere using IMAX

    DEFF Research Database (Denmark)

    Menn, W.; Hof, M.; Reimer, O.;

    1996-01-01

    with ancillary scintillators, time-of-flight, and aerogel cherenkov detectors. High resolution drift chambers and MWPCs were used as the tracking devices. Using redundant detectors, an extensive examination of the instrument efficiency was carried out. We present the absolute spectra of protons and helium...

  1. Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School

    Science.gov (United States)

    Bogacz, Bogdan F.; Pedziwiatr, Antoni T.

    2014-01-01

    A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…

  2. [Research on absolute calibration of sun channel of sun photometer using laser raster scanning method].

    Science.gov (United States)

    Xu, Wen-Bin; Li, Jian-Jun; Zheng, Xiao-Bing

    2013-01-01

    In the present paper, a new calibration method of absolute spectral irradiance responsivity of sun channel of sun photometer was developed. A tunable laser was used as source and a standard tranfer detector, calibrated against cryogenic absolute radiometer, was used to measure laser beam power. By raster scanning of a single collimated laser beam to generate the uniform irradiance field at the plane of effective aperture stop of sun photometer, the absolute irradiance responsivity of center wavelength of the 870 nm unpolarized sun channels of sun photometer was obtained accurately. The relative spectral irradiance responsivity of corresponding channel was obtained by using lamp-monochromator system and then used to acquire the absolute spectral irradiance responsivity in the laboratory. On the basis of the above results, the top-of-the-atmosphere responsive constant V0 was obtained by integration with extraterrestrial solar spectral irradiance data. Comparing the calibration result with that from GSFC, NASA in 2009, the difference is only 3.75%. In the last, the uncertainties of calibration were evaluated and reached to 2.06%. The principle feasibility of the new method was validated.

  3. [Absolute measurement of laminar flow with the aid of an orthogonal excitation technic in NMR tomography].

    Science.gov (United States)

    Bielke, G; Meindl, S; von Seelen, W

    1986-11-01

    A method for absolute measurement of flow quantities by excitation of a slice orthogonal to the measuring plane is presented. The developing flow profile can be imaged directly and its dynamic behaviour can be sampled and measured using the multiecho technique. Simple formulas can be derived by means of Hagen-Poiseuille's law for quantification.

  4. Absolute quantitation of proteins by Acid hydrolysis combined with amino Acid detection by mass spectrometry

    DEFF Research Database (Denmark)

    Mirgorodskaya, Olga A; Körner, Roman; Kozmin, Yuri P;

    2012-01-01

    Amino acid analysis is among the most accurate methods for absolute quantification of proteins and peptides. Here, we combine acid hydrolysis with the addition of isotopically labeled standard amino acids and analysis by mass spectrometry for accurate and sensitive protein quantitation....... Quantitation of less than 10 fmol of protein standards with errors below 10% has been demonstrated using this method (1)....

  5. Absolute measurement of the DT primary neutron yield on the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Leeper R.J.

    2013-11-01

    Full Text Available The measurement of the absolute neutron yield produced in inertial confinement fusion target experiments conducted on the National Ignition Facility (NIF is essential in benchmarking progress towards the goal of achieving ignition on this facility. This paper describes three independent diagnostic techniques that have been developed to make accurate and precise DT neutron yield measurements on the NIF.

  6. Hypercontractivity and Absolute Continuity of Gaussian Generalized Mehler Semigroups in Hilbert Spaces

    Institute of Scientific and Technical Information of China (English)

    Guo-lie Lan

    2006-01-01

    In this paper, we prove the hypercontractivity of a non-differentiable Gaussian generalized Mehler semigroup using direct probabilistic arguments. This result implies the exponential convergence of the semigroup at infinity. Under some additional hypotheses, we also establish the absolute continuity of the semigroup with respect to its invariant measure.

  7. The realization of absolute beauty: an interpretation of the fairytale Snow White.

    Science.gov (United States)

    Takenaka, Nanae

    2016-09-01

    This paper interprets the fairytale Snow White (Bruder Grimm 1857) in terms of the realization of absolute beauty. Jung's understanding that 'in myths and fairytales, as in dreams, the soul speaks about itself' (Jung 1945, para. 400), underpins such an approach. From this perspective a fantasy image is not about us, not about our unconsciousness, but is essentially about itself. The idea of absolute beauty first arises in the Queen's mind as a wish. Despite the Queen's strong desire to be named as the most beautiful person in the world, her mirror reflects that it is actually her daughter Snow White who is the fairest. Snow White might be regarded in the language of Giegerich as her internal other. Effectively they are separated into the Real that conceives the idea of absolute beauty and the Ideal that embodies it. The exchange that takes place between the two - mediated by mirror and window - generates the corpse of surpassing beauty that never decays but lies inaccessible behind the glass coffin. However the loving and penetrating gaze of the Prince, representing masculinity, succeeds in reanimating Snow White. Thus the Prince as the Other that is completely external and unknown to both the Queen and Snow White, specifically to their femininity, facilitates the realization of absolute beauty as the Ideal in the Real.

  8. The realization of absolute beauty: an interpretation of the fairytale Snow White.

    Science.gov (United States)

    Takenaka, Nanae

    2016-09-01

    This paper interprets the fairytale Snow White (Bruder Grimm 1857) in terms of the realization of absolute beauty. Jung's understanding that 'in myths and fairytales, as in dreams, the soul speaks about itself' (Jung 1945, para. 400), underpins such an approach. From this perspective a fantasy image is not about us, not about our unconsciousness, but is essentially about itself. The idea of absolute beauty first arises in the Queen's mind as a wish. Despite the Queen's strong desire to be named as the most beautiful person in the world, her mirror reflects that it is actually her daughter Snow White who is the fairest. Snow White might be regarded in the language of Giegerich as her internal other. Effectively they are separated into the Real that conceives the idea of absolute beauty and the Ideal that embodies it. The exchange that takes place between the two - mediated by mirror and window - generates the corpse of surpassing beauty that never decays but lies inaccessible behind the glass coffin. However the loving and penetrating gaze of the Prince, representing masculinity, succeeds in reanimating Snow White. Thus the Prince as the Other that is completely external and unknown to both the Queen and Snow White, specifically to their femininity, facilitates the realization of absolute beauty as the Ideal in the Real. PMID:27530170

  9. If the Shoe Fits: Virtue and Absolute Beauty in Fairy Tale Drama.

    Science.gov (United States)

    Thompson, Melissa C.

    2000-01-01

    Examines five versions of the Cinderella story. Argues that children's fairy tale drama presents female beauty as a moral absolute, not merely as a physical characteristic. Cites feminist theories of the female body to demonstrate ways in which fairy tale drama establishes female beauty as an unchanging, "universal" concept. Considers the…

  10. First Absolutely Calibrated Localized Measurements of Ion Velocity in the MST in Locked and Rotating Plasmas

    Science.gov (United States)

    Baltzer, M.; Craig, D.; den Hartog, D. J.; Nornberg, M. D.; Munaretto, S.

    2015-11-01

    An Ion Doppler Spectrometer (IDS) is used on MST for high time-resolution passive and active measurements of impurity ion emission. Absolutely calibrated measurements of flow are difficult because the spectrometer records data within 0.3 nm of the C+5 line of interest, and commercial calibration lamps do not produce lines in this narrow range . A novel optical system was designed to absolutely calibrate the IDS. The device uses an UV LED to produce a broad emission curve in the desired region. A Fabry-Perot etalon filters this light, cutting transmittance peaks into the pattern of the LED emission. An optical train of fused silica lenses focuses the light into the IDS with f/4. A holographic diffuser blurs the light cone to increase homogeneity. Using this light source, the absolute Doppler shift of ion emissions can be measured in MST plasmas. In combination with charge exchange recombination spectroscopy, localized ion velocities can now be measured. Previously, a time-averaged measurement along the chord bisecting the poloidal plane was used to calibrate the IDS; the quality of these central chord calibrations can be characterized with our absolute calibration. Calibration errors may also be quantified and minimized by optimizing the curve-fitting process. Preliminary measurements of toroidal velocity in locked and rotating plasmas will be shown. This work has been supported by the US DOE.

  11. The absolute chronology and thermal processing of solids in the solar protoplanetary disk

    DEFF Research Database (Denmark)

    Connelly, James Norman; Bizzarro, Martin; Krot, Alexander N.;

    2012-01-01

    Transient heating events that formed calcium-aluminum - rich inclusions (CAIs) and chondrules are fundamental processes in the evolution of the solar protoplanetary disk, but their chronology is not understood. Using U-corrected Pb-Pb dating, we determined absolute ages of individual CAIs...

  12. High absolute bioavailability of methylene blue given as an aqueous oral formulation

    OpenAIRE

    Walter-Sack, Ingeborg; Rengelshausen, Jens; Oberwittler, Heike; Burhenne, Juergen; Mueller, Olaf; Meissner, Peter; Mikus, Gerd

    2008-01-01

    Abstract Purpose Methylene blue (MB) has recently been reevaluated for malaria treatment. With the aim of excluding treatment failures due to low bioavailability, we have investigated the absolute bioavailability of MB given as an aqueous oral formulation and its interaction with chloroquine (CQ). Methods A phase...

  13. Estimation of Absolute Protein Quantities of Unlabeled Samples by Selected Reaction Monitoring Mass Spectrometry*

    OpenAIRE

    Ludwig, C; Claassen, M.; Schmidt, A; Aebersold, R.

    2012-01-01

    For many research questions in modern molecular and systems biology, information about absolute protein quantities is imperative. This information includes, for example, kinetic modeling of processes, protein turnover determinations, stoichiometric investigations of protein complexes, or quantitative comparisons of different proteins within one sample or across samples. To date, the vast majority of proteomic studies are limited to providing relative quantitative comparisons of protein levels...

  14. Forest ecosystems functioning of and conducting of forestry in the zones of absolute alienation

    International Nuclear Information System (INIS)

    The main regularities of forest ecosystems functioning in the zone of absolute alienation were shown. The radio contamination mozaicity of forest ecosystems was underlined. Regularities of 137Cs accumulation in the wood of the main arboreous species were analyzed. The detailed measures of forestry conducting and forests rehabilitation were proposed

  15. Absolute Quantitation of DNA Methylation of 28 Candidate Genes in Prostate Cancer Using Pyrosequencing

    Directory of Open Access Journals (Sweden)

    Nataڑa Vasiljeviš

    2011-01-01

    Full Text Available Aberrant DNA methylation plays a pivotal role in carcinogenesis and its mapping is likely to provide biomarkers for improved diagnostic and risk assessment in prostate cancer (PCa. We quantified and compared absolute methylation levels among 28 candidate genes in 48 PCa and 29 benign prostate hyperplasia (BPH samples using the pyrosequencing (PSQ method to identify genes with diagnostic and prognostic potential.

  16. Long term observation on absolute lymphocyte counts in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Total peripheral blood lymphocytes were evaluated by age and exposure status in the Adult Health Study population during three examination cycles between 1958 and 1972. No radiation effect was observed, but a significant drop in the absolute lymphocyte counts of those aged 70 years and over and a corresponding maximum for persons aged 50 - 59 was observed. (author)

  17. Absolute intensity of internal bremsstrahlung from the electron capture decay of 125I

    International Nuclear Information System (INIS)

    The absolute intensity of the internal bremsstrahlung spectrum accompanying the electron capture decay of 125I has been measured and compared to the recent calculation of Suric et al. The measured intensity above the 1s end point is found to be (86±10)% of the calculated intensity

  18. Effects of Three Resistance Training Programs on Muscular Strength and Absolute and Relative Endurance.

    Science.gov (United States)

    Anderson, Tim; Kearney, Jay T.

    1982-01-01

    The effects of three resistance training programs on male college students' muscular strength and absolute and relative muscular endurance were investigated. Results show that human skeletal muscle makes both general and specific adaptations to a training stimulus, and that the balance of these adaptations is to some extent dependent upon the…

  19. Inertial forces, absolute space, and Mach's principle: The genesis of relativity

    Science.gov (United States)

    Newburgh, Ronald

    2007-05-01

    The cornerstone of Newtonian mechanics is the inertial frame of reference. With this frame we can understand the difference between real and fictitious or pseudo forces and the importance of these two types of forces in Newton's analysis of his rotating bucket. This analysis was the basis of his belief in absolute space. Mach, who believed strongly in an empiricist view of science, showed that the existence of inertial forces leads to a refutation of absolute space. He replaced absolute space with a frame of reference at rest with respect to the distant fixed stars considered as a rigid system. His principle, which was not expressed explicitly by him, is that the inertia of a body is a consequence of its interaction with all other bodies in the universe. Mach's refutation of absolute space made Einstein's general theory of relativity possible. Einstein later abandoned Mach's principle and found the source of inertia in the nonzero curvature of the space-time metric, a fact that does not diminish the importance of Mach in Einstein's early thinking.

  20. New identification method for Hammerstein models based on approximate least absolute deviation

    Science.gov (United States)

    Xu, Bao-Chang; Zhang, Ying-Dan

    2016-07-01

    Disorder and peak noises or large disturbances can deteriorate the identification effects of Hammerstein non-linear models when using the least-square (LS) method. The least absolute deviation technique can be used to resolve this problem; however, its absolute value cannot meet the need of differentiability required by most algorithms. To improve robustness and resolve the non-differentiable problem, an approximate least absolute deviation (ALAD) objective function is established by introducing a deterministic function that exhibits the characteristics of absolute value under certain situations. A new identification method for Hammerstein models based on ALAD is thus developed in this paper. The basic idea of this method is to apply the stochastic approximation theory in the process of deriving the recursive equations. After identifying the parameter matrix of the Hammerstein model via the new algorithm, the product terms in the matrix are separated by calculating the average values. Finally, algorithm convergence is proven by applying the ordinary differential equation method. The proposed algorithm has a better robustness as compared to other LS methods, particularly when abnormal points exist in the measured data. Furthermore, the proposed algorithm is easier to apply and converges faster. The simulation results demonstrate the efficacy of the proposed algorithm.

  1. Absolute photonic band gap in 2D honeycomb annular photonic crystals

    International Nuclear Information System (INIS)

    Highlights: • A two-dimensional honeycomb annular photonic crystal (PC) is proposed. • The absolute photonic band gap (PBG) is studied. • Annular PCs show larger PBGs than usual air-hole PCs for high refractive index. • Annular PCs with anisotropic rods show large PBGs for low refractive index. • There exist optimal parameters to open largest band gaps. - Abstract: Using the plane wave expansion method, we investigate the effects of structural parameters on absolute photonic band gap (PBG) in two-dimensional honeycomb annular photonic crystals (PCs). The results reveal that the annular PCs possess absolute PBGs that are larger than those of the conventional air-hole PCs only when the refractive index of the material from which the PC is made is equal to 4.5 or larger. If the refractive index is smaller than 4.5, utilization of anisotropic inner rods in honeycomb annular PCs can lead to the formation of larger PBGs. The optimal structural parameters that yield the largest absolute PBGs are obtained

  2. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship.

    Science.gov (United States)

    Parry, Christopher; Blonquist, J Mark; Bugbee, Bruce

    2014-11-01

    In situ optical meters are widely used to estimate leaf chlorophyll concentration, but non-uniform chlorophyll distribution causes optical measurements to vary widely among species for the same chlorophyll concentration. Over 30 studies have sought to quantify the in situ/in vitro (optical/absolute) relationship, but neither chlorophyll extraction nor measurement techniques for in vitro analysis have been consistent among studies. Here we: (1) review standard procedures for measurement of chlorophyll; (2) estimate the error associated with non-standard procedures; and (3) implement the most accurate methods to provide equations for conversion of optical to absolute chlorophyll for 22 species grown in multiple environments. Tests of five Minolta (model SPAD-502) and 25 Opti-Sciences (model CCM-200) meters, manufactured from 1992 to 2013, indicate that differences among replicate models are less than 5%. We thus developed equations for converting between units from these meter types. There was no significant effect of environment on the optical/absolute chlorophyll relationship. We derive the theoretical relationship between optical transmission ratios and absolute chlorophyll concentration and show how non-uniform distribution among species causes a variable, non-linear response. These results link in situ optical measurements with in vitro chlorophyll concentration and provide insight to strategies for radiation capture among diverse species.

  3. Maple (Computer Algebra System) in Teaching Pre-Calculus: Example of Absolute Value Function

    Science.gov (United States)

    Tuluk, Güler

    2014-01-01

    Modules in Computer Algebra Systems (CAS) make Mathematics interesting and easy to understand. The present study focused on the implementation of the algebraic, tabular (numerical), and graphical approaches used for the construction of the concept of absolute value function in teaching mathematical content knowledge along with Maple 9. The study…

  4. A Multidimensional Approach to Explore the Understanding of the Notion of Absolute Value

    Science.gov (United States)

    Gagatsis, Athanasios; Panaoura, Areti

    2014-01-01

    The study aimed to investigate students' conceptions on the notion of absolute value and their abilities in applying the specific notion in routine and non-routine situations. A questionnaire was constructed and administered to 17-year-old students. Data were analysed using the hierarchical clustering of variables and the implicative method,…

  5. Absolute value representation of high-dimensional continuous piecewise linear functions

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    An absolute value representation of continuous piecewise linear functions at high-dimensional space has not been perfectly solved till now. The representation is given by using an iterative method, based on the representation at one-dimensional space. Meanwhile, it is proven that the novel representation is available for all high dimensional continuous piecewise linear functions.

  6. Socioeconomic determinants of male mortality in Europe: the absolute and relative income hypotheses revisited

    NARCIS (Netherlands)

    Spijker, J.; van Wissen, L.J.G.

    2010-01-01

    The main objective of this paper was to consider the influence of absolute and relative living standards (GDP per capita in Purchasing Power Parities and income inequality) on mortality differences between European countries.Rather than analysing all selected countries at once, Western and Eastern E

  7. Using the t-distribution to improve the absolute structure assignment with likelihood calculations

    NARCIS (Netherlands)

    Hooft, R.W.W.; Straver, L.H.; Spek, A.L.

    2010-01-01

    The previously described method for absolute structure determination [Hooft, Straver & Spek (2008). J. Appl. Cryst. 41, 96–103] assumes a Gaussian error distribution. The method is now extended to make it robust against poor data with large systematic errors with the introduction of the Student t-di

  8. Measurement of the absolute branching fraction of $D^{+}\\rightarrow\\bar K^0 e^{+}\

    CERN Document Server

    Ablikim, M; Ai, X C; Albayrak, O; Albrecht, M; Ambrose, D J; Amoroso, A; An, F F; An, Q; Bai, J Z; Ferroli, R Baldini; Ban, Y; Bennett, D W; Bennett, J V; Bertani, M; Bettoni, D; Bian, J M; Bianchi, F; Boger, E; Boyko, I; Briere, R A; Cai, H; Cai, X; Cakir, O; Calcaterra, A; Cao, G F; Cetin, S A; Chang, J F; Chelkov, G; Chen, G; Chen, H S; Chen, H Y; Chen, J C; Chen, M L; Chen, S; Chen, S J; Chen, X; Chen, X R; Chen, Y B; Cheng, H P; Chu, X K; Cibinetto, G; Dai, H L; Dai, J P; Dbeyssi, A; Dedovich, D; Deng, Z Y; Denig, A; Denysenko, I; Destefanis, M; De Mori, F; Ding, Y; Dong, C; Dong, J; Dong, L Y; Dong, M Y; Dou, Z L; Du, S X; Duan, P F; Fan, J Z; Fang, J; Fang, S S; Fang, X; Fang, Y; Farinelli, R; Fava, L; Fedorov, O; Feldbauer, F; Felici, G; Feng, C Q; Fioravanti, E; Fritsch, M; Fu, C D; Gao, Q; Gao, X L; Gao, X Y; Gao, Y; Gao, Z; Garzia, I; Goetzen, K; Gong, L; Gong, W X; Gradl, W; Greco, M; Gu, M H; Gu, Y T; Guan, Y H; Guo, A Q; Guo, L B; Guo, R P; Guo, Y; Guo, Y P; Haddadi, Z; Hafner, A; Han, S; Hao, X Q; Harris, F A; He, K L; Held, T; Heng, Y K; Hou, Z L; Hu, C; Hu, H M; Hu, J F; Hu, T; Hu, Y; Huang, G S; Huang, J S; Huang, X T; Huang, X Z; Huang, Y; Huang, Z L; Hussain, T; Ji, Q; Ji, Q P; Ji, X B; Ji, X L; Jiang, L W; Jiang, X S; Jiang, X Y; Jiao, J B; Jiao, Z; Jin, D P; Jin, S; Johansson, T; Julin, A; Kalantar-Nayestanaki, N; Kang, X L; Kang, X S; Kavatsyuk, M; Ke, B C; Kiese, P; Kliemt, R; Kloss, B; Kolcu, O B; Kopf, B; Kornicer, M; Kupsc, A; Kühn, W; Lange, J S; Lara, M; Larin, P; Leng, C; Li, C; Li, Cheng; Li, D M; Li, F; Li, F Y; Li, G; Li, H B; Li, H J; Li, J C; Li, Jin; Li, K; Li, K; Li, Lei; Li, P R; Li, Q Y; Li, T; Li, W D; Li, W G; Li, X L; Li, X N; Li, X Q; Li, Y B; Li, Z B; Liang, H; Liang, Y F; Liang, Y T; Liao, G R; Lin, D X; Liu, B; Liu, B J; Liu, C X; Liu, D; Liu, F H; Liu, Fang; Liu, Feng; Liu, H B; Liu, H H; Liu, H H; Liu, H M; Liu, J; Liu, J B; Liu, J P; Liu, J Y; Liu, K; Liu, K Y; Liu, L D; Liu, P L; Liu, Q; Liu, S B; Liu, X; Liu, Y B; Liu, Z A; Liu, Zhiqing; Loehner, H; Lou, X C; Lu, H J; Lu, J G; Lu, Y; Lu, Y P; Luo, C L; Luo, M X; Luo, T; Luo, X L; Lyu, X R; Ma, F C; Ma, H L; Ma, L L; Ma, M M; Ma, Q M; Ma, T; Ma, X N; Ma, X Y; Ma, Y M; Maas, F E; Maggiora, M; Mao, Y J; Mao, Z P; Marcello, S; Messchendorp, J G; Min, J; Min, T J; Mitchell, R E; Mo, X H; Mo, Y J; Morales, C Morales; Muchnoi, N Yu; Muramatsu, H; Nefedov, Y; Nerling, F; Nikolaev, I B; Ning, Z; Nisar, S; Niu, S L; Niu, X Y; Olsen, S L; Ouyang, Q; Pacetti, S; Pan, Y; Patteri, P; Pelizaeus, M; Peng, H P; Peters, K; Pettersson, J; Ping, J L; Ping, R G; Poling, R; Prasad, V; Qi, H R; Qi, M; Qian, S; Qiao, C F; Qin, L Q; Qin, N; Qin, X S; Qin, Z H; Qiu, J F; Rashid, K H; Redmer, C F; Ripka, M; Rong, G; Rosner, Ch; Ruan, X D; Sarantsev, A; Savrié, M; Schoenning, K; Schumann, S; Shan, W; Shao, M; Shen, C P; Shen, P X; Shen, X Y; Sheng, H Y; Shi, M; Song, W M; Song, X Y; Sosio, S; Spataro, S; Sun, G X; Sun, J F; Sun, S S; Sun, X H; Sun, Y J; Sun, Y Z; Sun, Z J; Sun, Z T; Tang, C J; Tang, X; Tapan, I; Thorndike, E H; Tiemens, M; Ullrich, M; Uman, I; Varner, G S; Wang, B; Wang, B L; Wang, D; Wang, D Y; Wang, K; Wang, L L; Wang, L S; Wang, M; Wang, P; Wang, P L; Wang, W; Wang, W P; Wang, X F; Wang, Y; Wang, Y D; Wang, Y F; Wang, Y Q; Wang, Z; Wang, Z G; Wang, Z H; Wang, Z Y; Wang, Z Y; Weber, T; Wei, D H; Weidenkaff, P; Wen, S P; Wiedner, U; Wolke, M; Wu, L H; Wu, L J; Wu, Z; Xia, L; Xia, L G; Xia, Y; Xiao, D; Xiao, H; Xiao, Z J; Xie, Y G; Xiu, Q L; Xu, G F; Xu, J J; Xu, L; Xu, Q J; Xu, Q N; Xu, X P; Yan, L; Yan, W B; Yan, W C; Yan, Y H; Yang, H J; Yang, H X; Yang, L; Yang, Y X; Ye, M; Ye, M H; Yin, J H; Yu, B X; Yu, C X; Yu, J S; Yuan, C Z; Yuan, W L; Yuan, Y; Yuncu, A; Zafar, A A; Zallo, A; Zeng, Y; Zeng, Z; Zhang, B X; Zhang, B Y; Zhang, C; Zhang, C C; Zhang, D H; Zhang, H H; Zhang, H Y; Zhang, J; Zhang, J J; Zhang, J L; Zhang, J Q; Zhang, J W; Zhang, J Y; Zhang, J Z; Zhang, K; Zhang, L; Zhang, S Q; Zhang, X Y; Zhang, Y; Zhang, Y H; Zhang, Y N; Zhang, Y T; Zhang, Yu; Zhang, Z H; Zhan, Z P; Zhang, Z Y; Zhao, G; Zhao, J W; Zhao, J Y; Zhao, J Z; Zhao, Lei; Zhao, Ling; Zhao, M G; Zhao, Q; Zhao, Q W; Zhao, S J; Zhao, T C; Zhao, Y B; Zhao, Z G; Zhemchugov, A; Zheng, B; Zheng, J P; Zheng, W J; Zheng, Y H; Zhong, B; Zhou, L; Zhou, X; Zhou, X K; Zhou, X R; Zhou, X Y; Zhu, K; Zhu, K J; Zhu, S; Zhu, S H; Zhu, X L; Zhu, Y C; Zhu, Y S; Zhu, Z A; Zhuang, J; Zotti, L; Zou, B S; Zou, J H

    2016-01-01

    By analyzing 2.93 fb$^{-1}$ data collected at the center-of-mass energy $\\sqrt s=3.773$ GeV with the BESIII detector, we measure the absolute branching fraction of the semileptonic decay $D^+\\rightarrow\\bar K^0 e^{+}\

  9. Relative and Absolute Error Control in a Finite-Difference Method Solution of Poisson's Equation

    Science.gov (United States)

    Prentice, J. S. C.

    2012-01-01

    An algorithm for error control (absolute and relative) in the five-point finite-difference method applied to Poisson's equation is described. The algorithm is based on discretization of the domain of the problem by means of three rectilinear grids, each of different resolution. We discuss some hardware limitations associated with the algorithm,…

  10. Sub-femtosecond absolute timing precision with a 10 GHz hybrid photonic-microwave oscillator

    CERN Document Server

    Fortier, T M; Hati, A; Quinlan, F; Taylor, J; Jiang, H; Chou, C W; Rosenband, T; Lemke, N; Ludlow, A; Howe, D; Oates, C W; Diddams, S A

    2012-01-01

    We present an optical-electronic approach to generating microwave signals with high spectral purity. By circumventing shot noise and operating near fundamental thermal limits, we demonstrate 10 GHz signals with an absolute timing jitter for a single hybrid oscillator of 420 attoseconds (1Hz - 5 GHz).

  11. Transferability of dipole moment derivatives: A general method for the calculation of absolute rotational contributions

    NARCIS (Netherlands)

    Smit, W.M.A.; Bode, J.H.G.; Straten, A.J. van

    1979-01-01

    A general method for the calculation of absolute rotational corrections for the dipole moment derivatives is given based on the definition of pure geometrical distortions. The method is generally valid and allows the rotational contributions to be calculated for all modes of any molecule. The relati

  12. Absolute Transition Probabilities of Lines in the Spectra of Astrophysical Atoms, Molecules, and Ions

    Science.gov (United States)

    Parkinson, W. H.; Smith, P. L.; Yoshino, K.

    1984-01-01

    Progress in the investigation of absolute transition probabilities (A-values or F values) for ultraviolet lines is reported. A radio frequency ion trap was used for measurement of transition probabilities for intersystem lines seen in astronomical spectra. The intersystem line at 2670 A in Al II, which is seen in pre-main sequence stars and symbiotic stars, was studied.

  13. Absolute instability from linear conversion of counter-propagating positive and negative energy waves

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, A.N.; Brizard, A.J.; Morehead, J.J. [Lawrence Berkeley National Lab., CA (United States); Tracy, E.R. [College of William and Mary, Williamsburg, VA (United States)

    1997-12-31

    The resonant interaction of a negative-energy wave with a positive-energy wave gives rise to a linear instability. Whereas a single crossing of rays in a nonuniform medium leads to a convectively saturated instability, we show that a double crossing can yield an absolute instability.

  14. Absolute pitch in Costa Rica: Distribution of pitch identification ability and implications for its genetic basis.

    Science.gov (United States)

    Chavarria-Soley, Gabriela

    2016-08-01

    Absolute pitch is the unusual ability to recognize a pitch without an external reference. The current view is that both environmental and genetic factors are involved in the acquisition of the trait. In the present study, 127 adult musicians were subjected to a musical tone identification test. Subjects were university music students and volunteers who responded to a newspaper article. The test consisted of the identification of 40 piano and 40 pure tones. Subjects were classified in three categories according to their pitch naming ability: absolute pitch (AP), high accuracy of tone identification (HA), and non-absolute pitch (non-AP). Both the percentage of correct responses and the mean absolute deviation showed a statistically significant variation between categories. A very clear pattern of higher accuracy for white than for black key notes was observed for the HA and the non-AP groups. Meanwhile, the AP group had an almost perfect pitch naming accuracy for both kinds of tones. Each category presented a very different pattern of deviation around the correct response. The age at the beginning of musical training did not differ between categories. The distribution of pitch identification ability in this study suggests a complex inheritance of the trait. PMID:27586721

  15. Absolute and convective instabilities in a one-dimensional Brusselator flow model

    DEFF Research Database (Denmark)

    Kuznetsov, S.P.; Mosekilde, Erik; Dewel, G.;

    1997-01-01

    The paper considers a one-dimensional Brusselator model with a uniform flow of the mixture of reaction components. An absolute as well as a convective instability can arise for both the Hopf and the Turing modes. The corresponding linear stability analysis is presented and supported by the results...

  16. Simulation model for a silicon Hall sensor in an absolute digital position detection system

    NARCIS (Netherlands)

    Pronk, F.A.; Groenland, J.P.J.; Lammerink, T.S.J.

    1986-01-01

    The performance of a digital position detection system with silicon Hall sensors for the detection of coded absolute position data has been investigated. The position information is fixed in one single track as a maximum length sequence of bits by means of longitudinal saturation recording in a hard

  17. Magnetic force microscopy reveals meta-stable magnetic domain states that prevent reliable absolute palaeointensity experiments

    NARCIS (Netherlands)

    de Groot, Lennart; Fabian, Karl; Bakelaar, Iman A.; Dekkers, Mark J.

    2014-01-01

    Obtaining reliable estimates of the absolute palaeointensity of the Earth's magnetic field is notoriously difficult. The heating of samples in most methods induces magnetic alteration-a process that is still poorly understood, but prevents obtaining correct field values. Here we show induced changes

  18. Measurements of the absolute branching fractions for $D_{s}^{+}\\rightarrow\\eta e^{+}\

    CERN Document Server

    Ablikim, M; Ai, X C; Albayrak, O; Albrecht, M; Ambrose, D J; Amoroso, A; An, F F; An, Q; Bai, J Z; Ferroli, R Baldini; Ban, Y; Bennett, D W; Bennett, J V; Bertani, M; Bettoni, D; Bian, J M; Bianchi, F; Boger, E; Boyko, I; Briere, R A; Cai, H; Cai, X; Cakir, O; Calcaterra, A; Cao, G F; Cetin, S A; Chang, J F; Chelkov, G; Chen, G; Chen, H S; Chen, H Y; Chen, J C; Chen, M L; Chen, S; Chen, S J; Chen, X; Chen, X R; Chen, Y B; Cheng, H P; Chu, X K; Cibinetto, G; Dai, H L; Dai, J P; Dbeyssi, A; Dedovich, D; Deng, Z Y; Denig, A; Denysenko, I; Destefanis, M; De Mori, F; Ding, Y; Dong, C; Dong, J; Dong, L Y; Dong, M Y; Dou, Z L; Du, S X; Duan, P F; Fan, J Z; Fang, J; Fang, S S; Fang, X; Fang, Y; Farinelli, R; Fava, L; Fedorov, O; Feldbauer, F; Felici, G; Feng, C Q; Fioravanti, E; Fritsch, M; Fu, C D; Gao, Q; Gao, X L; Gao, X Y; Gao, Y; Gao, Z; Garzia, I; Goetzen, K; Gong, L; Gong, W X; Gradl, W; Greco, M; Gu, M H; Gu, Y T; Guan, Y H; Guo, A Q; Guo, L B; Guo, R P; Guo, Y; Guo, Y P; Haddadi, Z; Hafner, A; Han, S; Hao, X Q; Harris, F A; He, K L; Held, T; Heng, Y K; Hou, Z L; Hu, C; Hu, H M; Hu, J F; Hu, T; Hu, Y; Huang, G S; Huang, J S; Huang, X T; Huang, X Z; Huang, Y; Huang, Z L; Hussain, T; Ji, Q; Ji, Q P; Ji, X B; Ji, X L; Jiang, L W; Jiang, X S; Jiang, X Y; Jiao, J B; Jiao, Z; Jin, D P; Jin, S; Johansson, T; Julin, A; Kalantar-Nayestanaki, N; Kang, X L; Kang, X S; Kavatsyuk, M; Ke, B C; Kiese, P; Kliemt, R; Kloss, B; Kolcu, O B; Kopf, B; Kornicer, M; Kupsc, A; Kühn, W; Lange, J S; Lara, M; Larin, P; Leng, C; Li, C; Li, Cheng; Li, D M; Li, F; Li, F Y; Li, G; Li, H B; Li, H J; Li, J C; Li, Jin; Li, K; Li, K; Li, Lei; Li, P R; Li, Q Y; Li, T; Li, W D; Li, W G; Li, X L; Li, X N; Li, X Q; Li, Y B; Li, Z B; Liang, H; Liang, Y F; Liang, Y T; Liao, G R; Lin, D X; Liu, B; Liu, B J; Liu, C X; Liu, D; Liu, F H; Liu, Fang; Liu, Feng; Liu, H B; Liu, H H; Liu, H H; Liu, H M; Liu, J; Liu, J B; Liu, J P; Liu, J Y; Liu, K; Liu, K Y; Liu, L D; Liu, P L; Liu, Q; Liu, S B; Liu, X; Liu, Y B; Liu, Z A; Liu, Zhiqing; Loehner, H; Lou, X C; Lu, H J; Lu, J G; Lu, Y; Lu, Y P; Luo, C L; Luo, M X; Luo, T; Luo, X L; Lyu, X R; Ma, F C; Ma, H L; Ma, L L; Ma, M M; Ma, Q M; Ma, T; Ma, X N; Ma, X Y; Ma, Y M; Maas, F E; Maggiora, M; Mao, Y J; Mao, Z P; Marcello, S; Messchendorp, J G; Min, J; Min, T J; Mitchell, R E; Mo, X H; Mo, Y J; Morales, C Morales; Muchnoi, N Yu; Muramatsu, H; Nefedov, Y; Nerling, F; Nikolaev, I B; Ning, Z; Nisar, S; Niu, S L; Niu, X Y; Olsen, S L; Ouyang, Q; Pacetti, S; Pan, Y; Patteri, P; Pelizaeus, M; Peng, H P; Peters, K; Pettersson, J; Ping, J L; Ping, R G; Poling, R; Prasad, V; Qi, H R; Qi, M; Qian, S; Qiao, C F; Qin, L Q; Qin, N; Qin, X S; Qin, Z H; Qiu, J F; Rashid, K H; Redmer, C F; Ripka, M; Rong, G; Rosner, Ch; Ruan, X D; Sarantsev, A; Savrié, M; Schoenning, K; Schumann, S; Shan, W; Shao, M; Shen, C P; Shen, P X; Shen, X Y; Sheng, H Y; Shi, M; Song, W M; Song, X Y; Sosio, S; Spataro, S; Sun, G X; Sun, J F; Sun, S S; Sun, X H; Sun, Y J; Sun, Y Z; Sun, Z J; Sun, Z T; Tang, C J; Tang, X; Tapan, I; Thorndike, E H; Tiemens, M; Ullrich, M; Uman, I; Varner, G S; Wang, B; Wang, B L; Wang, D; Wang, D Y; Wang, K; Wang, L L; Wang, L S; Wang, M; Wang, P; Wang, P L; Wang, W; Wang, W P; Wang, X F; Wang, Y; Wang, Y D; Wang, Y F; Wang, Y Q; Wang, Z; Wang, Z G; Wang, Z H; Wang, Z Y; Wang, Z Y; Weber, T; Wei, D H; Weidenkaff, P; Wen, S P; Wiedner, U; Wolke, M; Wu, L H; Wu, L J; Wu, Z; Xia, L; Xia, L G; Xia, Y; Xiao, D; Xiao, H; Xiao, Z J; Xie, Y G; Xiu, Q L; Xu, G F; Xu, J J; Xu, L; Xu, Q J; Xu, Q N; Xu, X P; Yan, L; Yan, W B; Yan, W C; Yan, Y H; Yang, H J; Yang, H X; Yang, L; Yang, Y X; Ye, M; Ye, M H; Yin, J H; Yu, B X; Yu, C X; Yu, J S; Yuan, C Z; Yuan, W L; Yuan, Y; Yuncu, A; Zafar, A A; Zallo, A; Zeng, Y; Zeng, Z; Zhang, B X; Zhang, B Y; Zhang, C; Zhang, C C; Zhang, D H; Zhang, H H; Zhang, H Y; Zhang, J; Zhang, J J; Zhang, J L; Zhang, J Q; Zhang, J W; Zhang, J Y; Zhang, J Z; Zhang, K; Zhang, L; Zhang, S Q; Zhang, X Y; Zhang, Y; Zhang, Y H; Zhang, Y N; Zhang, Y T; Zhang, Yu; Zhang, Z H; Zhan, Z P; Zhang, Z Y; Zhao, G; Zhao, J W; Zhao, J Y; Zhao, J Z; Zhao, Lei; Zhao, Ling; Zhao, M G; Zhao, Q; Zhao, Q W; Zhao, S J; Zhao, T C; Zhao, Y B; Zhao, Z G; Zhemchugov, A; Zheng, B; Zheng, J P; Zheng, W J; Zheng, Y H; Zhong, B; Zhou, L; Zhou, X; Zhou, X K; Zhou, X R; Zhou, X Y; Zhu, K; Zhu, K J; Zhu, S; Zhu, S H; Zhu, X L; Zhu, Y C; Zhu, Y S; Zhu, Z A; Zhuang, J; Zotti, L; Zou, B S; Zou, J H

    2016-01-01

    By analyzing 482 pb$^{-1}$ of $e^+e^-$ collision data collected at $\\sqrt s=4.009$ GeV with the BESIII detector at the BEPCII storage ring, we measure the absolute branching fractions for the semileptonic decays $D_{s}^{+}\\to\\eta e^{+}\

  19. Predicting AIDS-related events using CD4 percentage or CD4 absolute counts

    Directory of Open Access Journals (Sweden)

    Donabedian Haig

    2006-08-01

    Full Text Available Abstract Background The extent of immunosuppression and the probability of developing an AIDS-related complication in HIV-infected people is usually measured by the absolute number of CD4 positive T-cells. The percentage of CD4 positive cells is a more easily measured and less variable number. We analyzed sequential CD4 and CD8 numbers, percentages and ratios in 218 of our HIV infected patients to determine the most reliable predictor of an AIDS-related event. Results The CD4 percentage was an unsurpassed predictor of the occurrence of AIDS-related events when all subsets of patients are considered. The CD4 absolute count was the next most reliable, followed by the ratio of CD4/CD8 percentages. The value of CD4 percentage over the CD4 absolute count was seen even after the introduction of highly effective HIV therapy. Conclusion The CD4 percentage is unsurpassed as a parameter for predicting the onset of HIV-related diseases. The extra time and expense of measuring the CD4 absolute count may be unnecessary.

  20. Ny strid, Ny svid : En fallstudie av Absolut Vodkas visuella kommunikation med avseende på målgruppspositionering.

    OpenAIRE

    Svanlindh, Niklas; von Friedrichs Grängsjö, Anna

    2013-01-01

    Title: A new battle, the same bottle: A case study of the visual communication of Absolut Vodka and how it’s positioned towards different market segments. Author: Anna von Friedrichs Grängsjö & Niklas Svanlindh Tutor: Jessica Gustafsson Purpose: To overview the visual communication of Absolut Vodka and how it’s positioned towards different market segments. Absolut Vodka is a brand that reaches a vast range of consumers through a single consistent marketing strategy. The hypothesis was tha...

  1. General practitioners’ use of absolute risk versus individual risk factors in cardiovascular disease prevention: an experimental study

    OpenAIRE

    Jansen, Jesse; Bonner, Carissa; McKinn, Shannon; Irwig, Les; Glasziou, Paul ,; Doust, Jenny; Teixeira-Pinto, Armando; Hayen, Andrew; Turner, Robin; McCaffery, Kirsten

    2014-01-01

    Objective To understand general practitioners’ (GPs) use of individual risk factors (blood pressure and cholesterol levels) versus absolute risk in cardiovascular disease (CVD) risk management decision-making. Design Randomised experiment. Absolute risk, systolic blood pressure (SBP), cholesterol ratio (total cholesterol/high-density lipoprotein (TC/HDL)) and age were systematically varied in hypothetical cases. High absolute risk was defined as 5-year risk of a cardiovascular event >15%, hig...

  2. Reduced content of chloroatranol and atranol in oak moss absolute significantly reduces the elicitation potential of this fragrance material

    DEFF Research Database (Denmark)

    Andersen, Flemming; Andersen, Kirsten H; Bernois, Armand;

    2015-01-01

    BACKGROUND: Oak moss absolute, an extract from the lichen Evernia prunastri, is a valued perfume ingredient but contains extreme allergens. OBJECTIVES: To compare the elicitation properties of two preparations of oak moss absolute: 'classic oak moss', the historically used preparation, and 'new oak...

  3. Vibrational Circular Dichroism Absolute Configuration of 9,12-Cyclomulin-13-ol, a Diterpene from Azorella and Laretia Species.

    Science.gov (United States)

    Muñoz, Marcelo A; San-Martín, Aurelio; Joseph-Nathan, Pedro

    2015-08-01

    The absolute configuration of the diterpenoid 9,12-cyclomulin-13-ol (1), a constituent of Azorella and Laretia species, has been established by vibrational circular dichroism spectroscopy in combination with density functional theory calculations. The obtained normal diterpene absolute configuration confirms that of azorellanol (2), which was determined by single crystal X-ray diffraction.

  4. A novel method for the absolute fluorescence yield measurement by AIRFLY

    CERN Document Server

    Ave, M

    2008-01-01

    One of the goals of the AIRFLY (AIR FLuorescence Yield) experiment is to measure the absolute fluorescence yield induced by electrons in air to better than 10% precision. We introduce a new technique for measurement of the absolute fluorescence yield of the 337 nm line that has the advantage of reducing the systematic uncertainty due to the detector calibration. The principle is to compare the measured fluorescence yield to a well known process - the Cerenkov emission. Preliminary measurements taken in the BFT (Beam Test Facility) in Frascati, Italy with 350 MeV electrons are presented. Beam tests in the Argonne Wakefield Accelerator at the Argonne National Laboratory, USA with 14 MeV electrons have also shown that this technique can be applied at lower energies.

  5. Gender equality and women's absolute status: a test of the feminist models of rape.

    Science.gov (United States)

    Martin, Kimberly; Vieraitis, Lynne M; Britto, Sarah

    2006-04-01

    Feminist theory predicts both a positive and negative relationship between gender equality and rape rates. Although liberal and radical feminist theory predicts that gender equality should ameliorate rape victimization, radical feminist theorists have argued that gender equality may increase rape in the form of male backlash. Alternatively, Marxist criminologists focus on women's absolute socioeconomic status rather than gender equality as a predictor of rape rates, whereas socialist feminists combine both radical and Marxist perspectives. This study uses factor analysis to overcome multicollinearity limitations of past studies while exploring the relationship between women's absolute and relative socioeconomic status on rape rates in major U.S. cities using 2000 census data. The findings indicate support for both the Marxist and radical feminist explanations of rape but no support for the ameliorative hypothesis. These findings support a more inclusive socialist feminist theory that takes both Marxist and radical feminist hypotheses into account.

  6. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  7. Frequency Domain Criteria for Absolute Stability A Delay-integral-quadratic Constraints Approach

    CERN Document Server

    Altshuller, Dmitry

    2013-01-01

    Frequency Domain Criteria for Absolute Stability focuses on recently-developed methods of delay-integral-quadratic constraints to provide criteria for absolute stability of nonlinear control systems. The known or assumed properties of the system are the basis from which stability criteria are developed. Through these methods, many classical results are naturally extended, particularly to time-periodic but also to nonstationary systems. Mathematical prerequisites including Lebesgue-Stieltjes measures and integration are first explained in an informal style with technically more difficult proofs presented in separate sections that can be omitted without loss of continuity. The results are presented in the frequency domain – the form in which they naturally tend to arise. In some cases, the frequency-domain criteria can be converted into computationally tractable linear matrix inequalities but in others, especially those with a certain geometric interpretation, inferences concerning stability can be made direc...

  8. Improvements in the absolute standardization of large-area reference sources.

    Science.gov (United States)

    Stanga, D; De Felice, P

    2009-09-01

    Using a simple gas-gain model, the efficiency sensitivity of gas-flow proportional counters to changes in the influence quantities (applied anode voltage, gas purity, gas-flow rate, ambient pressure and temperature) was analyzed and applied for the absolute standardization of large-area reference sources. Thus, the uncertainty of measurement was evaluated by taking into account the fluctuations of these quantities in normal conditions of counter operation. It was shown that the uncertainty is small in these conditions but accidental and large changes in the influence quantities may give rise to large errors of measurement. In addition, a cleaning procedure and a simple way of stabilizing the gain of gas-flow proportional counters were used to improve the absolute standardization of large-area reference sources. As a result, measurements were performed with uncertainties smaller than 0.55% and the reproducibility better than 0.42%. PMID:19376713

  9. Absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer.

    Science.gov (United States)

    Hirano, Masahiro; Katoh, Munenori

    2015-07-01

    [Purpose] The aim of this study was to verify the absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD). [Subjects and Methods] The subjects were 33 healthy college students. The measurements were made three times with the HHD fixed using a belt (BFHHD) or with the examiner's hand (conventional method; HFHHD). The absolute reliability of measurements was verified using Bland-Altman analysis, both in the all subjects group and a group of subjects showing measurements less than a fixed limit of 30 kgf. [Results] In the adductor muscle strength, single measurements obtained using an HFHHD in the case of a <30 kgf group and the maximum value of two measurements obtained using a BFHHD are reliable. PMID:26311938

  10. Absolute brightness temperature measurements at 3.5-mm wavelength. [of sun, Venus, Jupiter and Saturn

    Science.gov (United States)

    Ulich, B. L.; Rhodes, P. J.; Davis, J. H.; Hollis, J. M.

    1980-01-01

    Careful observations have been made at 86.1 GHz to derive the absolute brightness temperatures of the sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7 K), and Saturn (153.4 + or - 4.8 K) with a standard error of about three percent. This is a significant improvement in accuracy over previous results at millimeter wavelengths. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the Millimeter Wave Observatory (MWO) 4.9-m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5-mm wavelength.

  11. Relative and absolute level populations in beam-foil-excited neutral helium

    Science.gov (United States)

    Davidson, J.

    1975-01-01

    Relative and absolute populations of 19 levels in beam-foil-excited neutral helium at 0.275 MeV have been measured. The singlet angular-momentum sequences show dependences on principal quantum number consistent with n to the -3rd power, but the triplet sequences do not. Singlet and triplet angular-momentum sequences show similar dependences on level excitation energy. Excitation functions for six representative levels were measured in the range from 0.160 to 0.500 MeV. The absolute level populations increase with energy, whereas the neutral fraction of the beam decreases with energy. Further, the P angular-momentum levels are found to be overpopulated with respect to the S and D levels. The overpopulation decreases with increasing principal quantum number.

  12. Absolute Absorption Cross Sections from Photon Recoil in a Matter-Wave Interferometer

    Science.gov (United States)

    Eibenberger, Sandra; Cheng, Xiaxi; Cotter, J. P.; Arndt, Markus

    2014-06-01

    We measure the absolute absorption cross section of molecules using a matter-wave interferometer. A nanostructured density distribution is imprinted onto a dilute molecular beam through quantum interference. As the beam crosses the light field of a probe laser some molecules will absorb a single photon. These absorption events impart a momentum recoil which shifts the position of the molecule relative to the unperturbed beam. Averaging over the shifted and unshifted components within the beam leads to a reduction of the fringe visibility, enabling the absolute absorption cross section to be extracted with high accuracy. This technique is independent of the molecular density, it is minimally invasive and successfully eliminates many problems related to photon cycling, state mixing, photobleaching, photoinduced heating, fragmentation, and ionization. It can therefore be extended to a wide variety of neutral molecules, clusters, and nanoparticles.

  13. Absolute absorption cross sections from photon recoil in a matter-wave interferometer

    CERN Document Server

    Eibenberger, Sandra; Cotter, J P; Arndt, Markus

    2014-01-01

    We measure the absolute absorption cross section of molecules using a matter-wave interferometer. A nanostructured density distribution is imprinted onto a dilute molecular beam through quantum interference. As the beam crosses the light field of a probe laser some molecules will absorb a single photon. These absorption events impart a momentum recoil which shifts the position of the molecule relative to the unperturbed beam. Averaging over the shifted and unshifted components within the beam leads to a reduction of the fringe visibility, enabling the absolute absorption cross section to be extracted with high accuracy. This technique is independent of the molecular density, it is minimally invasive and successfully eliminates all problems related to photon-cycling, state-mixing, photo-bleaching, photo-induced heating, fragmentation and ionization. It can therefore be extended to a wide variety of neutral molecules, clusters and nanoparticles.

  14. Absolute reaction rate measurement with D-D neutron source in polyethylene spherical shell

    International Nuclear Information System (INIS)

    The absolute reaction rate distribution measurements in a polyethylene spherical shell with 38.6 cm outside diameter and 10 cm thickness were performed with D-D neutron source. By combining fission method and activation method, rich-uranium fission chamber, depleted-uranium fission chamber, 237Np fission chamber and 115In activation foils were placed at several positions on the equatorial line of the inner face of the shell, and the absolute reaction rates were obtained. The uncertainty of fission rates is 2.5%-4.3%, while the uncertainty of activation rates is about 6.3%. The reaction rates were calculated by MCNP and ENDF/B-VII. 0. The calculated results are lower than the measured results and 238U is typical. (authors)

  15. A targeted proteomics toolkit for high-throughput absolute quantification of Escherichia coli proteins.

    Science.gov (United States)

    Batth, Tanveer S; Singh, Pragya; Ramakrishnan, Vikram R; Sousa, Mirta M L; Chan, Leanne Jade G; Tran, Huu M; Luning, Eric G; Pan, Eva H Y; Vuu, Khanh M; Keasling, Jay D; Adams, Paul D; Petzold, Christopher J

    2014-11-01

    Transformation of engineered Escherichia coli into a robust microbial factory is contingent on precise control of metabolism. Yet, the throughput of omics technologies used to characterize cell components has lagged far behind our ability to engineer novel strains. To expand the utility of quantitative proteomics for metabolic engineering, we validated and optimized targeted proteomics methods for over 400 proteins from more than 20 major pathways in E. coli metabolism. Complementing these methods, we constructed a series of synthetic genes to produce concatenated peptides (QconCAT) for absolute quantification of the proteins and made them available through the Addgene plasmid repository (www.addgene.org). To facilitate high sample throughput, we developed a fast, analytical-flow chromatography method using a 5.5-min gradient (10 min total run time). Overall this toolkit provides an invaluable resource for metabolic engineering by increasing sample throughput, minimizing development time and providing peptide standards for absolute quantification of E. coli proteins.

  16. Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2016-05-01

    Full Text Available A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interesting is that this differential capacitive sensor is only sensitive to one translational degree of freedom (DOF movement, and immune to the vibration along the other two translational DOFs. In the experiment, we used a novel circuit based on an AC capacitance bridge to directly measure the differential capacitance value. The experimental result shows that this differential capacitive sensor has a sensitivity of 2 × 10−4 pF/μm with 0.08 μm resolution. The measurement range of this differential capacitive sensor is 6 mm, and the linearity error are less than 0.01% over the whole absolute position measurement range.

  17. Land Use in LCIA: an absolute scale proposal for Biotic Production Potential

    DEFF Research Database (Denmark)

    Saez de Bikuna Salinas, Koldo; Ibrom, Andreas; Hauschild, Michael Zwicky

    , the present study proposes a single absolute scale for the midpoint impact category (MIC) of Biotic Production Potential (BPP). It is hypothesized that, for an ecosystem in equilibrium (where NPP equals decay), such an ecosystem has reached the maximum biotic throughput subject to site-specific conditions......Environmental impacts caused by land occupation and transformation have been bypassed in many LCA studies due to soils’ multifunctionality and the interconnectedness between the ecosystem services they provide. These inherent modelling complexities have traditionally forced LCA practitioners...... and no externally added inputs. The original ecosystem (or Potential Natural Vegetation) of a certain land gives then the maximum BPP with no additional, downstream or upstream, impacts. This Natural BPP is proposed as the maximum BPP in a hypothetical Absolute Scale for LCA’s Land Use framework. It is argued...

  18. An Overview of the Use of Absolute Dating Techniques in Ancient Construction Materials

    Directory of Open Access Journals (Sweden)

    Jorge Sanjurjo-Sánchez

    2016-04-01

    Full Text Available The reconstruction of the chronology of historical buildings is a tricky issue, as usually there are not historical documents that allow the assessment of construction phases, and some materials are hardly reliable for the use of dating techniques (e.g., stone. However, in the last two decades, important advances on the use of absolute dating methods on building materials have increased the possibilities of reconstructing building chronologies, although some advances are still scarcely known among archaeologists and architects. Recent studies performed on several kinds of mortars, fired bricks, mud-bricks, and even stone surfaces have shown that it is possible to date them. Both radiocarbon and luminescence dating have been the most frequently used techniques but others such as archaeomagnetism can also be used in some cases. This paper intends to give an overview of the recent achievements on the use of absolute dating techniques for building materials.

  19. Measuring Absolute RNA Copy Numbers at High Temporal Resolution Reveals Transcriptome Kinetics in Development

    Directory of Open Access Journals (Sweden)

    Nick D.L. Owens

    2016-01-01

    Full Text Available Transcript regulation is essential for cell function, and misregulation can lead to disease. Despite technologies to survey the transcriptome, we lack a comprehensive understanding of transcript kinetics, which limits quantitative biology. This is an acute challenge in embryonic development, where rapid changes in gene expression dictate cell fate decisions. By ultra-high-frequency sampling of Xenopus embryos and absolute normalization of sequence reads, we present smooth gene expression trajectories in absolute transcript numbers. During a developmental period approximating the first 8 weeks of human gestation, transcript kinetics vary by eight orders of magnitude. Ordering genes by expression dynamics, we find that “temporal synexpression” predicts common gene function. Remarkably, a single parameter, the characteristic timescale, can classify transcript kinetics globally and distinguish genes regulating development from those involved in cellular metabolism. Overall, our analysis provides unprecedented insight into the reorganization of maternal and embryonic transcripts and redefines our ability to perform quantitative biology.

  20. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    International Nuclear Information System (INIS)

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces

  1. Absolute Differential Cross Sections for Elastic Scattering of Electrons from CO at Intermediate and High Energies

    Institute of Scientific and Technical Information of China (English)

    SHI De-Heng; LIU Yu-Fang; SUN Jin-Feng; YANG Xiang-Dong; ZHU Zun-Lue

    2005-01-01

    @@ The additivity rule model together with the complex optical model potential correlated by the concept of bonded atoms, which considers the overlapping effect of electron clouds between two atoms in a molecule, is firstly employed to calculate the absolute differential cross sections for electrons scattered by carbon monoxide at intermediate and high energies at the Hartree-Fock level. A comparison of elastic differential cross section results, obtained by using the correlated complex optical model potential, with the available experimental data,shows a significant improvement over the uncorrelated ones. The differential cross sections obtained by using the correlated complex optical model potential are in very good agreement with the experimental data. It is shown that the additivity rule model together with the correlated complex optical model potential is suitable for the calculations of the absolute differential cross sections of e-CO scattering.

  2. Motor preparatory activity in posterior parietal cortex is modulated by subjective absolute value.

    Directory of Open Access Journals (Sweden)

    Asha Iyer

    Full Text Available For optimal response selection, the consequences associated with behavioral success or failure must be appraised. To determine how monetary consequences influence the neural representations of motor preparation, human brain activity was scanned with fMRI while subjects performed a complex spatial visuomotor task. At the beginning of each trial, reward context cues indicated the potential gain and loss imposed for correct or incorrect trial completion. FMRI-activity in canonical reward structures reflected the expected value related to the context. In contrast, motor preparatory activity in posterior parietal and premotor cortex peaked in high "absolute value" (high gain or loss conditions: being highest for large gains in subjects who believed they performed well while being highest for large losses in those who believed they performed poorly. These results suggest that the neural activity preceding goal-directed actions incorporates the absolute value of that action, predicated upon subjective, rather than objective, estimates of one's performance.

  3. Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window.

    Science.gov (United States)

    Bai, Yang; Lu, Yunfeng; Hu, Pengcheng; Wang, Gang; Xu, Jinxin; Zeng, Tao; Li, Zhengkun; Zhang, Zhonghua; Tan, Jiubin

    2016-01-01

    A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interesting is that this differential capacitive sensor is only sensitive to one translational degree of freedom (DOF) movement, and immune to the vibration along the other two translational DOFs. In the experiment, we used a novel circuit based on an AC capacitance bridge to directly measure the differential capacitance value. The experimental result shows that this differential capacitive sensor has a sensitivity of 2 × 10(-4) pF/μm with 0.08 μm resolution. The measurement range of this differential capacitive sensor is 6 mm, and the linearity error are less than 0.01% over the whole absolute position measurement range. PMID:27187393

  4. A Laser Frequency Comb System for Absolute Calibration of the VTT Echelle Spectrograph

    CERN Document Server

    Doerr, H -P; Holzwarth, R; Schmidt, T Kentischer und W

    2012-01-01

    A wavelength calibration system based on a laser frequency comb (LFC) was developed in a co-operation between the Kiepenheuer-Institut f\\"ur Sonnenphysik, Freiburg, Germany and the Max-Planck-Institut f\\"ur Quantenoptik, Garching, Germany for permanent installation at the German Vacuum Tower Telescope (VTT) on Tenerife, Canary Islands. The system was installed successfully in October 2011. By simultaneously recording the spectra from the Sun and the LFC, for each exposure a calibration curve can be derived from the known frequencies of the comb modes that is suitable for absolute calibration at the meters per second level. We briefly summarize some topics in solar physics that benefit from absolute spectroscopy and point out the advantages of LFC compared to traditional calibration techniques. We also sketch the basic setup of the VTT calibration system and its integration with the existing echelle spectrograph.

  5. Absolute measurement of the nitrogen fluorescence yield in air between 300 and 430 nm

    CERN Document Server

    Lefeuvre, G; Gorodetzky, P; Patzak, T; Salin, P

    2007-01-01

    The nitrogen fluorescence induced in air is used to detect ultra-high energy cosmic rays and to measure their energy. The precise knowledge of the absolute fluorescence yield is the key quantity to improve the accuracy on the cosmic ray energy. The total yield has been measured in dry air using a 90Sr source and a [300-430 nm] filter. The fluorescence yield in air is 4.23 $\\pm$ 0.20 photons per meter when normalized to 760 mmHg, 15 degrees C and with an electron energy of 0.85 MeV. This result is consistent with previous experiments made at various energies, but with an accuracy improved by a factor of about 3. For the first time, the absolute continuous spectrum of nitrogen excited by 90Sr electrons has also been measured with a spectrometer. Details of this experiment are given in one of the author's PhD thesis [32].

  6. Gender equality and women's absolute status: a test of the feminist models of rape.

    Science.gov (United States)

    Martin, Kimberly; Vieraitis, Lynne M; Britto, Sarah

    2006-04-01

    Feminist theory predicts both a positive and negative relationship between gender equality and rape rates. Although liberal and radical feminist theory predicts that gender equality should ameliorate rape victimization, radical feminist theorists have argued that gender equality may increase rape in the form of male backlash. Alternatively, Marxist criminologists focus on women's absolute socioeconomic status rather than gender equality as a predictor of rape rates, whereas socialist feminists combine both radical and Marxist perspectives. This study uses factor analysis to overcome multicollinearity limitations of past studies while exploring the relationship between women's absolute and relative socioeconomic status on rape rates in major U.S. cities using 2000 census data. The findings indicate support for both the Marxist and radical feminist explanations of rape but no support for the ameliorative hypothesis. These findings support a more inclusive socialist feminist theory that takes both Marxist and radical feminist hypotheses into account. PMID:16567334

  7. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  8. Special Relativity in Absolute Space: from a contradiction in terms to an obviousness

    CERN Document Server

    Guerra, V; Guerra, Vasco; Abreu, Rodrigo de

    2006-01-01

    This work deals with the questions of absolute space and relativity. In particular, an alternative derivation of the effects described by special relativity is provided, which is based on a description that assumes a privileged reference frame. The present theory follows the ideas of Lorentz and Poincare, abandoning a strict view of Einstein's "equivalence" of all inertial frames. The meaning of the Principle of Relativity is discussed and elucidated, and it is shown that it is not incompatible with the existence of a preferred, absolute, frame. Most scientists nowadays still consider the basic assumptions of the theory proposed here to be plain wrong. Moreover, they tend to see an irreconcilable conflict between the Lorentz-Poincare and the Einstein-Minkowski formulations. However, as stated by John Bell [Bell1988], although there is a stringent "difference in philosophy" between both views, "the facts of physics do not oblige us to accept one philosophy rather than the other". The validity of Bell's asserti...

  9. Three Sesquiterpenoid Dimers from Chloranthus japonicus: Absolute Configuration of Chlorahololide A and Related Compounds.

    Science.gov (United States)

    Shi, Xin-Wei; Lu, Qiang-Qiang; Pescitelli, Gennaro; Ivšić, Trpimir; Zhou, Jun-Hui; Gao, Jin-Ming

    2016-02-01

    A novel sesquiterpenoid dimer, named multistalide C (1), together with two known congeners, shizukaols C (2) and D (3), was isolated from the whole plant of Chloranthus japonicus Sieb. The structures of compounds 1-3 were elucidated by extensive HR-ESI-MS, 1D, and 2D NMR spectroscopic analysis. Compounds 1-3 exhibited significant toxic effects on brine shrimp larvae (Artemia salina). The absolute configuration of 1 was established by CD/TDDFT calculations. The related compound chlorahololide A was also reinvestigated. The previous assignment of the absolute configuration of chlorahololide A and several related sesquiterpenoid dimers, based on an incorrect application of the exciton chirality method, is criticized. PMID:26708509

  10. Relative and absolute level populations in beam-foil--excited neutral helium

    International Nuclear Information System (INIS)

    Relative and absolute populations of 19 levels in beam-foil--excited neutral helium at 0.275 MeV have been measured. The singlet angular-momentum sequences show dependences on principal quantum number consistent with n-3, but the triplet sequences do not. Singlet and triplet angular-momentum sequences show similar dependences on level excitation energy. Excitation functions for six representative levels were measured in the range 0.160 to 0.500 MeV. The absolute level populations increase with energy, whereas the neutral fraction of the beam decreases with energy. Further, the P angular-momentum levels are found to be overpopulated with respect to the S and D levels. The overpopulation decreases with increasing principal quantum number

  11. The Absolute, Relative and Multi-Wavelength Calibration of the Pierre Auger Observatory Fluorescence Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Knapik, R.; Bauleo, P.; Becker, B.R.; Brack, J.; Caruso, R.; Fratte, C.Delle; Dorofeev, A.; Harton, J.; Insolia, A.; Matthews, J.A.J.; Menshikov, A.

    2007-08-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single measurement. The relative response has been measured at wavelengths of 320, 337, 355, 380 and 405 nm, defining a spectral response curve which has been normalized to the absolute calibration. Before and after each night of data taking a relative calibration of the phototubes is performed. This relative calibration is used to track both short and long term changes in the detector's response. A cross check of the calibration in some phototubes is performed using an independent laser technique. Overall uncertainties, current results and future plans are discussed.

  12. Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window

    Science.gov (United States)

    Bai, Yang; Lu, Yunfeng; Hu, Pengcheng; Wang, Gang; Xu, Jinxin; Zeng, Tao; Li, Zhengkun; Zhang, Zhonghua; Tan, Jiubin

    2016-01-01

    A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interesting is that this differential capacitive sensor is only sensitive to one translational degree of freedom (DOF) movement, and immune to the vibration along the other two translational DOFs. In the experiment, we used a novel circuit based on an AC capacitance bridge to directly measure the differential capacitance value. The experimental result shows that this differential capacitive sensor has a sensitivity of 2 × 10−4 pF/μm with 0.08 μm resolution. The measurement range of this differential capacitive sensor is 6 mm, and the linearity error are less than 0.01% over the whole absolute position measurement range. PMID:27187393

  13. Absolute triple differential cross sections for photo-double ionization of helium-experiment and theory

    Energy Technology Data Exchange (ETDEWEB)

    Braeuning, H. [Department of Physics, Kansas State University, Manhattan, KA 66506 (United States); Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Doerner, R.; Braeuning-Demian, A.; Mergel, V.; Schmidt-Boecking, H. [Institut fuer Kernphysik, Universitaet Frankfurt, August-Euler-Strasse 6, D60486 Frankfurt (Germany); Cocke, C.L.; Carnes, K.; Richard, P. [Department of Physics, Kansas State University, Manhattan, KA 66506 (United States); Prior, M.H.; Dreuil, S. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Kraessig, B. [Argonne National Laboratory, Argonne, IL 60439 (United States); Kheifets, A.S. [Australian National University, Canberra ACT 0200 (Australia); Bray, I. [Flinders University, GPO Box 2100, Adelaide 5001 (Australia); Ullrich, J. [Universitaet Freiburg, 79104 Freiburg (Germany)

    1998-12-14

    We have measured absolute triple differential cross sections for photo-double ionization of helium at 20 eV excess. The measurement covers the full ranges of energy sharing and emission angles of the two photoelectrons. We compare our data for selected geometries with the convergent close-coupling (CCC) calculations as well as 2SC calculations by Pont and Shakeshaft and 3C calculations by Maulbetsch and Briggs. In terms of the absolute magnitude and the trend in the shapes of the triple differential cross section for different geometries we find good agreement of the CCC and published 2SC calculations with our measurement, though differences with respect to the observed shape of individual patterns still exist. (author)

  14. Experimental assessment of the speed of light perturbation in free-fall absolute gravimeters

    Science.gov (United States)

    Baumann, H.; Pythoud, F.; Blas, D.; Sibiryakov, S.; Eichenberger, A.; Klingelé, E. E.

    2015-10-01

    Precision absolute gravity measurements are growing in importance, especially in the context of the new definition of the kilogram. For the case of free fall absolute gravimeters with a Michelson-type interferometer tracking the position of a free falling body, one of the effects that needs to be taken into account is the ‘speed of light perturbation’ due to the finite speed of propagation of light. This effect has been extensively discussed in the past, and there is at present a disagreement between different studies. In this work, we present the analysis of new data and confirm the result expected from the theoretical analysis applied nowadays in free-fall gravimeters. We also review the standard derivations of this effect (by using phase shift or Doppler effect arguments) and show their equivalence.

  15. Experimental assessment of the speed of light perturbation in free-fall absolute gravimeters

    CERN Document Server

    Baumann, H; Blas, D.; Sibiryakov, S.; Eichenberger, A.; Klingelé, E.E.

    2015-01-01

    Precision absolute gravity measurements are growing in importance, especially in the context of the new definition of the kilogram. For the case of free-fall absolute gravimeters with a Michelson-type interferometer tracking the position of a free falling body, one of the effects that needs to be taken into account is the speed of light perturbation due to the finite speed of propagation of light. This effect has been extensively discussed in the past, and there is at present a disagreement between different studies. In this work, we present the analysis of new data and confirm the result expected from the theoretical analysis applied nowadays in free-fall gravimeters. We also review the standard derivations of this effect (by using phase shift or Doppler effect arguments) and show their equivalence.

  16. Multiphase permittivity imaging using absolute value electrical capacitance tomography data and a level set algorithm.

    Science.gov (United States)

    Al Hosani, E; Soleimani, M

    2016-06-28

    Multiphase flow imaging is a very challenging and critical topic in industrial process tomography. In this article, simulation and experimental results of reconstructing the permittivity profile of multiphase material from data collected in electrical capacitance tomography (ECT) are presented. A multiphase narrowband level set algorithm is developed to reconstruct the interfaces between three- or four-phase permittivity values. The level set algorithm is capable of imaging multiphase permittivity by using one set of ECT measurement data, so-called absolute value ECT reconstruction, and this is tested with high-contrast and low-contrast multiphase data. Simulation and experimental results showed the superiority of this algorithm over classical pixel-based image reconstruction methods. The multiphase level set algorithm and absolute ECT reconstruction are presented for the first time, to the best of our knowledge, in this paper and critically evaluated. This article is part of the themed issue 'Supersensing through industrial process tomography'. PMID:27185966

  17. Estimation of peak relative velocity and peak absolute acceleration of linear SDOF systems

    Institute of Scientific and Technical Information of China (English)

    Jianwei Song; Yi-Lun Chu; Zach Liang; George C. Lee

    2007-01-01

    In the seismic analysis and design of structures, the true velocity and absolute acceleration are usually approximated by their corresponding pseudo-values. This approach is simple and works well for structures with small damping (say, less than 15%). When the damping of a structure is enhanced for the purpose of response reduction, it may result in large analysis and design errors. Based on theory of random vibration and the established mechanism of seismic response spectra analysis, a method is developed (1) to predict the relative velocity spectra with any damping ratio level directly from the 5% standard pseudo-acceleration spectrum; and (2) to estimate the peak absolute acceleration. The accuracy of both is validated by using two selected ensembles of ground motion records.

  18. A Laser Frequency Comb System for Absolute Calibration of the VTT Echelle Spectrograph

    Science.gov (United States)

    Doerr, H.-P.; Steinmetz, T.; Holzwarth, R.; Kentischer, T.; Schmidt, W.

    2012-10-01

    A wavelength calibration system based on a laser frequency comb (LFC) was developed in a co-operation between the Kiepenheuer-Institut für Sonnenphysik, Freiburg, Germany and the Max-Planck-Institut für Quantenoptik, Garching, Germany for permanent installation at the German Vacuum Tower Telescope (VTT) on Tenerife, Canary Islands. The system was installed successfully in October 2011. By simultaneously recording the spectra from the Sun and the LFC, for each exposure a calibration curve can be derived from the known frequencies of the comb modes that is suitable for absolute calibration at the meters per second level. We briefly summarize some topics in solar physics that benefit from absolute spectroscopy and point out the advantages of LFC compared to traditional calibration techniques. We also sketch the basic setup of the VTT calibration system and its integration with the existing echelle spectrograph.

  19. Absolute density-profile tomography of molecular beams using multiphoton ionization

    International Nuclear Information System (INIS)

    We describe an approach for the absolute density measurement of rotationally symmetric molecular beams via multiphoton ionization. This simple single-projection tomographic technique requires only knowledge of the spatial intensity profile and ionization characteristics of the focused laser beam that probes the pulsed molecular jet. Multiphoton ionization (MPI) of a xenon beam allowed tomographic reconstruction of a two-dimensional density profile with a peak density of (4.2±0.4)x1018 m-3, which was compared with the theoretical predictions of the sudden freeze model. An analytic solution to the Abel transform is derived for Gaussian projected density profiles which greatly simplifies the reconstruction of the absolute radial density. MPI is sufficiently general that this technique can be readily applied to atomic beams with a broad range of chemistries.

  20. Frequency-scanning interferometry for dynamic absolute distance measurement using Kalman filter.

    Science.gov (United States)

    Tao, Long; Liu, Zhigang; Zhang, Weibo; Zhou, Yangli

    2014-12-15

    We propose a frequency-scanning interferometry using the Kalman filtering technique for dynamic absolute distance measurement. Frequency-scanning interferometry only uses a single tunable laser driven by a triangle waveform signal for forward and backward optical frequency scanning. The absolute distance and moving speed of a target can be estimated by the present input measurement of frequency-scanning interferometry and the previously calculated state based on the Kalman filter algorithm. This method not only compensates for movement errors in conventional frequency-scanning interferometry, but also achieves high-precision and low-complexity dynamic measurements. Experimental results of dynamic measurements under static state, vibration and one-dimensional movement are presented. PMID:25503050