WorldWideScience

Sample records for absolute spectrophotometer firas

  1. Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Shafer, R. A.; Eplee, R. E.; Isaacman, R. B.; Fixsen, D. J.; Read, S. M.; Meyer, S. S.; Weiss, R.; Wright, E. L.

    1991-01-01

    The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.

  2. Cosmology and Dust from the COBE FIRAS

    Science.gov (United States)

    Mather, John C.

    1995-12-01

    I report the results of an analysis of improved data sets from the COBE FIRAS (Far Infrared Absolute Spectrophotometer) experiment. The new data sets have been analyzed to obtain improved limits, with smaller error bars, on the distortion of the cosmic microwave background radiation relative to a pure blackbody. These place strong constraints on exotic energy releases in the early universe. Also, an extension of the Principal Component analysis has provided new information on Galactic dust and limits on a far infrared cosmic background (FIRB) in the 0.1 - 0.5 mm range. Although the FIRAS data are consistent with a FIRB that is a significant fraction of the Galactic brightness at the poles, they can also be explained in terms of spatial variations of the properties of the interstellar medium. I acknowledge the FIRAS team, and especially D. J. Fixsen and R. A. Shafer, for the improved data sets and significant contributions to the analyses reported here. The National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC) is responsible for the design, development, and operation of the Cosmic Background Explorer (COBE), under the scientific guidance of the COBE Science Working Group. GSFC is also responsible for the software development and the final processing of the mission data.

  3. Cosmic microwave background dipole spectrum measured by the COBE FIRAS instrument

    Science.gov (United States)

    Fixsen, D. J.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Isaacman, R. B.; Mather, J. C.; Meyer, S. S.; Noerdlinger, P. D.; Shafer, R. A.; Weiss, R.

    1994-01-01

    The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) has determined the dipole spectrum of the cosmic microwave background radiation (CMBR) from 2 to 20/cm. For each frequency the signal is decomposed by fitting to a monopole, a dipole, and a Galactic template for approximately 60% of the sky. The overall dipole spectrum fits the derivative of a Planck function with an amplitude of 3.343 +/- 0.016 mK (95% confidence level), a temperature of 2.714 +/- 0.022 K (95% confidence level), and an rms deviation of 6 x 10(exp -9) ergs/sq cm/s/sr cm limited by a detector and cosmic-ray noise. The monopole temperature is consistent with that determined by direct measurement in the accompanying article by Mather et al.

  4. Normal incidence spectrophotometer using high density transmission grating technology and highly efficiency silicon photodiodes for absolute solar EUV irradiance measurements

    Science.gov (United States)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Korde, R.

    1992-01-01

    New developments in transmission grating and photodiode technology now make it possible to realize spectrometers in the extreme ultraviolet (EUV) spectral region (wavelengths less than 1000 A) which are expected to be virtually constant in their diffraction and detector properties. Time dependent effects associated with reflection gratings are eliminated through the use of free standing transmission gratings. These gratings together with recently developed and highly stable EUV photodiodes have been utilized to construct a highly stable normal incidence spectrophotometer to monitor the variability and absolute intensity of the solar 304 A line. Owing to its low weight and compactness, such a spectrometer will be a valuable tool for providing absolute solar irradiance throughout the EUV. This novel instrument will also be useful for cross-calibrating other EUV flight instruments and will be flown on a series of Hitchhiker Shuttle Flights and on SOHO. A preliminary version of this instrument has been fabricated and characterized, and the results are described.

  5. Measurement of the cosmic microwave background spectrum by the COBE FIRAS instrument

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Fixsen, D. J.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Meyer, S. S.; Noerdlinger, P. D.

    1994-01-01

    The cosmic microwave background radiation (CMBR) has a blackbody spectrum within 3.4 x 10(exp -8) ergs/sq cm/s/sr cm over the frequency range from 2 to 20/cm (5-0.5 mm). These measurements, derived from the Far-Infrared Absolute Spectrophotomer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite, imply stringent limits on energy release in the early universe after t approximately 1 year and redshift z approximately 3 x 10(exp 6). The deviations are less than 0.30% of the peak brightness, with an rms value of 0.01%, and the dimensionless cosmological distortion parameters are limited to the absolute value of y is less than 2.5 x 10(exp -5) and the absolute value of mu is less than 3.3 x 10(exp -4) (95% confidence level). The temperature of the CMBR is 2.726 +/- 0.010 K (95% confidence level systematic).

  6. Optical fiber spectrophotometer

    International Nuclear Information System (INIS)

    Zhuang Weixin; Tian Guocheng; Ye Guoan; Zhou Zhihong; Cheng Weiwei; Huang Lifeng; Liu Suying; Tang Yanji; Hu Jingxin; Zhao Yonggang

    1998-12-01

    A method called 'Two Arm's Photo out and Electricity Send-back' is introduced. UV-365 UV/VIS/NIR spectrophotometer has been reequipped by this way with 5 meters long optical fiber. Another method called 'One Arm's Photo out and Photo Send-back' is also introduced. λ 19 UV/VIS/NIR spectrophotometer has been reequipped by this way with 10 meters long optical fiber. Optical fiber spectrophotometer can work as its main set. So it is particularly applicable to radio activity work

  7. Multichannel scanning spectrophotometer

    International Nuclear Information System (INIS)

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  8. Performance assessment of Vita Easy Shade spectrophotometer on colour measurement of aesthetic dental materials.

    Science.gov (United States)

    AlGhazali, N; Burnside, G; Smith, R W; Preston, A J; Jarad, F D

    2011-12-01

    Four different shades were used to produce 20 samples of resin-based composite and 20 samples of porcelain to evaluate the performance ability of an intra oral test spectrophotometer compared to a reference spectrophotometer. The absolute colour coordinates CIELAB values measured with both spectrophotometers were significantly different (p spectrophotometers (p < 0.05). Therefore, the Easy Shade can be used in dental practice and dental research with some limitations.

  9. Dobson ozone spectrophotometer modification.

    Science.gov (United States)

    Komhyr, W. D.; Grass, R. D.

    1972-01-01

    Description of a modified version of the Dobson ozone spectrophotometer in which several outdated electronic design features have been replaced by circuitry embodying more modern design concepts. The resulting improvement in performance characteristics has been obtained without changing the principle of operation of the original instrument.

  10. Development of Raman spectrophotometer

    International Nuclear Information System (INIS)

    Adam, A.I.

    2008-05-01

    In this work, the Raman spectrophotometer HG.2S Jobin Yvon rebuilt and developed, the Raman setup provided as a gift for Neelian University from Amsterdam University. The main parts, which were replaced, include monochromator, an air-cooled photomultiplier tube RCA IP 28, log amplifier, hand scanning lab VIEW card for computer interfacing. The components assembled and the whole device was tested successfully. The developed setup was checked using some standard solutions, which showed perfect consistency with literature in the references and published papers. Solutions included hexane, cyclohexane, carbon tetrachloride, benzene and sodium sulfate.(Author)

  11. Atomic absorption spectrophotometer

    International Nuclear Information System (INIS)

    Stockdale, T. J.

    1985-01-01

    In atomic absorption spectrophotometer, a reference path may be provided for radiation which excludes the flame. This radiation provides a signal from a detector which varies only with the instrumental drift produced by variations in the radiation source brightness and by variations in detector gain. The signal can be used to compensate for drift in other signals received through a sample path including the flame. In the present invention, radiation passes through the sample path continuously during measurement, and only through the reference path between sample measurements. Movable mirrors shift the radiation between the paths upon externally applied commands. Conveniently, the reference path measurement is made while the flame is stabilized during the change between samples. The reference path measurements are stored and used to correct for drift

  12. Optoelectronics instrumentation of a spectrophotometer

    International Nuclear Information System (INIS)

    Lopez, A.; Camas, J.; Rios, C.; Lopez, F.; Anzueto, G.; Castannon, J.; Dominguez, J.

    2016-01-01

    Today, it is necessary to characterize materials to generate knowledge and propose new technology in the development of optical sensors. However, the acquisition of spectrophotometers is not easy for the researchers that not have an economic resource. So, in this paper the design of a spectrophotometer is presented using optical technology such as light source, light and electron scattering commercially available in Mexico, and whose construction is cheap and easy to build. (Author)

  13. Filter indexing for spectrophotometer system

    International Nuclear Information System (INIS)

    Chamran, M.M.; Scott, L.B.; Williams, P.B.

    1982-01-01

    A spectrophotometer system has an optical system for transmitting a beam from a source at select wavelengths onto a detector. A plurality of filters are positioned in a tray. A stepper mechanism indexes the tray along a path. A microcomputer controls the stepper mechanism and the optical system. The wavelength is successively changed over a range, the tray is indexed to move a select filter into the beam at a predetermined wavelength and the changing is discontinued during indexing

  14. Modernization of Atomic Absorption Spectrophotometer

    International Nuclear Information System (INIS)

    Tasic, Visa; Milivojevic, Dragan; Karabasevic, Dejan

    2003-01-01

    In Copper Institute in Bor, connection has been made between absorption spectrophotometer and standard PC with the aim to make its operation more reliable and comfortable. Applied solution includes both software and hardware components. An I/O interface module has been installed in PC [1]. Software component consists of programs for measuring and interpretation of results. Paper presents details of this job realization.(Author)

  15. Shutter mechanism for spacecraft spectrophotometer

    Science.gov (United States)

    Weilbach, A.

    1972-01-01

    A shutter mechanism is described for the backscatter ultraviolet spectrophotometer experiment on the Nimbus D satellite. The purpose of the experiment is to determine spatial distribution of atmospheric ozone from measurements of ultraviolet radiation backscattered by the earth's atmosphere. The system consists of two independent, rotary cylinder shutters, controlled by a dual star Geneva mechanism, and driven by a single stepper motor. A single driver controls a combination of two independently driven Geneva stars. Design considerations involved the use of low friction, nonmetallic materials.

  16. Method and apparatus for calibrating spectrophotometers

    NARCIS (Netherlands)

    Schreutelkamp, F.H.

    2003-01-01

    The present invention relates to a method of calibrating spectrophotometers by placing one or more filters in the light path of the spectrophotometer and measuring the amount of radiation by means of a detector. The present invention furthermore relates to an apparatus to be used with such a method.

  17. A Low-Cost Quantitative Absorption Spectrophotometer

    Science.gov (United States)

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  18. Absolute advantage

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2008-01-01

    textabstractA country is said to have an absolute advantage over another country in the production of a good or service if it can produce that good or service using fewer real resources. Equivalently, using the same inputs, the country can produce more output. The concept of absolute advantage can

  19. Fiber optic spectrophotometer with photodiode linear array

    International Nuclear Information System (INIS)

    Blanc, F.; Vernet, P.

    1988-01-01

    Spectrophotometric measurements are used in a great number of industrial processes, in nuclear environment and with optical precision components. Especially the evolution of a chemical process or of an optical coating could be followed by these measurements. Spectrophotometers, using optical fibers to transport the signal out of the instrument make possible the measurement ''in-situ'' and in real time. The advantage of using a diode array to detect the signal is an instantaneous measurement all over the spectral range without moving parts. It allows an excellent reproductibility. The instrument is controlled by a micro computer. The spectrophotometer is described and technical performance presented. An extension using optical fibers on a ''classical'' spectrophotometer (a H.P. one) is also described and technical performance presented

  20. The Fuge Tube Diode Array Spectrophotometer

    Science.gov (United States)

    Arneson, B. T.; Long, S. R.; Stewart, K. K.; Lagowski, J. J.

    2008-01-01

    We present the details for adapting a diode array UV-vis spectrophotometer to incorporate the use of polypropylene microcentrifuge tubes--fuge tubes--as cuvettes. Optical data are presented validating that the polyethylene fuge tubes are equivalent to the standard square cross section polystyrene or glass cuvettes generally used in…

  1. Enzyme Activity Experiments Using a Simple Spectrophotometer

    Science.gov (United States)

    Hurlbut, Jeffrey A.; And Others

    1977-01-01

    Experimental procedures for studying enzyme activity using a Spectronic 20 spectrophotometer are described. The experiments demonstrate the effect of pH, temperature, and inhibitors on enzyme activity and allow the determination of Km, Vmax, and Kcat. These procedures are designed for teaching large lower-level biochemistry classes. (MR)

  2. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  3. Modification of a commercial spectrophotometer for photoacoustic measurement

    International Nuclear Information System (INIS)

    Bandyopadhyay, S.; Harris, J.M.; Eyring, E.M.

    1983-01-01

    This note describes how a commercial UV-VIS-NIR spectrophotometer may be adapted to function as a double beam photoacoustic spectrophotometer operating at visible wavelengths. Modification of a Varian Cary 17 spectrophotometer was carried out first by dismounting the photomultiplier tube detector module and the cell compartment of the spectrophotometer. The sample and the reference beams were focused through two externally mounted quartz lenses onto the sample and reference photoacoustic cells, respectively

  4. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  5. A Simple Spectrophotometer Using Common Materials and a Digital Camera

    Science.gov (United States)

    Widiatmoko, Eko; Widayani; Budiman, Maman; Abdullah, Mikrajuddin; Khairurrijal

    2011-01-01

    A simple spectrophotometer was designed using cardboard, a DVD, a pocket digital camera, a tripod and a computer. The DVD was used as a diffraction grating and the camera as a light sensor. The spectrophotometer was calibrated using a reference light prior to use. The spectrophotometer was capable of measuring optical wavelengths with a…

  6. On the radiative and thermodynamic properties of the cosmic radiations using COBE FIRAS instrument data: I. Cosmic microwave background radiation

    Science.gov (United States)

    Fisenko, Anatoliy I.; Lemberg, Vladimir

    2014-07-01

    Using the explicit form of the functions to describe the monopole and dipole spectra of the Cosmic Microwave Background (CMB) radiation, the exact expressions for the temperature dependences of the radiative and thermodynamic functions, such as the total radiation power per unit area, total energy density, number density of photons, Helmholtz free energy density, entropy density, heat capacity at constant volume, and pressure in the finite range of frequencies v 1≤ v≤ v 2 are obtained. Since the dependence of temperature upon the redshift z is known, the obtained expressions can be simply presented in z representation. Utilizing experimental data for the monopole and dipole spectra measured by the COBE FIRAS instrument in the 60-600 GHz frequency interval at the temperature T=2.72548 K, the values of the radiative and thermodynamic functions, as well as the radiation density constant a and the Stefan-Boltzmann constant σ are calculated. In the case of the dipole spectrum, the constants a and σ, and the radiative and thermodynamic properties of the CMB radiation are obtained using the mean amplitude T amp=3.358 mK. It is shown that the Doppler shift leads to a renormalization of the radiation density constant a, the Stefan-Boltzmann constant σ, and the corresponding constants for the thermodynamic functions. The expressions for new astrophysical parameters, such as the entropy density/Boltzmann constant, and number density of CMB photons are obtained. The radiative and thermodynamic properties of the Cosmic Microwave Background radiation for the monopole and dipole spectra at redshift z≈1089 are calculated.

  7. Brewer spectrophotometer measurements in the Canadian Arctic

    Science.gov (United States)

    Kerr, J. B.; Evans, W. F. J.

    1988-01-01

    In the winters of 1987 and 1988 measurements were conducted with the Brewer Spectrophotometer at Alert (82.5 N) and Resolute (74.5 N). The measurements were conducted as part of our Canadian Program to search for an Arctic Ozone Hole (CANOZE). Ozone measurements were conducted in the months of December, January and February using the moon as a light source. The total ozone measurements will be compared with ozonesonde profiles, from ECC sondes, flown once per week from Alert and Resolute. A modified Brewer Spectrophotometer was used in a special study to search for chlorine dioxide at Alert in March 1987. Ground based observations at Saskatoon in February and at Alert in March 1987 failed to detect any measureable chlorine dioxide. Interference from another absorbing gas, which we speculate may be nitrous acid, prevented the measurements at the low levels of chlorine dioxide detected in the Southern Hemisphere by Solomon et al.

  8. The EUV spectrophotometer on Atmosphere Explorer.

    Science.gov (United States)

    Hinteregger, H. E.; Bedo, D. E.; Manson, J. E.

    1973-01-01

    An extreme ultraviolet (EUV) spectrophotometer for measurements of solar radiation at wavelengths ranging from 140 to 1850 A will be included in the payload of each of the three Atmosphere-Explorer (AE) missions, AE-C, -D, and -E. The instrument consists of 24 grating monochromators, 12 of which can be telecommanded either to execute 128-step scans each covering a relatively small section of the total spectrophotometer wavelength range or to maintain fixed (command-selected) wavelength positions. The remaining 12 nonscan monochromators operate at permanently fixed wavelengths and view only a small fraction of the solar disk except for one viewing the whole sun in H Lyman alpha. Ten of the 12 scan-capable monochromators also view the entire solar disk since their primary function is to measure the total fluxes independent of the distribution of sources across the solar disk.

  9. Conversion of Beckman DK-2A spectrophotometer into an automatic single-photon counting fluorescence spectrophotometer

    International Nuclear Information System (INIS)

    Chikkur, G.C.; Lagare, M.T.; Umakantha, N.

    1981-01-01

    Details of how a DK-2A spectrophotometer can be modified into an automatic single-photon counting fluorescence spectrophotometer for recording a low intensity spectrum, are reported. The single-photon count-rate converted into a DC voltage is applied at the appropriate stage in the sample channel amplifier circuit of a DK-2A to get the pen deflection proportional to the count-rate. A high intensity spectrum may be recorded in the usual way by merely turning the shaft of the mirror motor by 180 degrees. (author)

  10. [Assessment of tooth bleaching efficacy with spectrophotometer].

    Science.gov (United States)

    Zhu, Wenhao; Liu, Chang; Pan, Jie

    2014-06-01

    To analyze the changes in CIE L*, a*, and b* at cervical, body, and incisal sites after tooth bleaching by using a spectrophotometer. Sixty-seven intact and healthy maxillary central incisors were in-vestigated. These incisors were darker than A3 according to the Vita Classical shade guide. The CIE tooth shade parameters L*, a*, and b* were simultaneously recorded at three tooth areas (cervical, body, and incisal) with a spectrophotometer before and after tooth bleaching (35%H2O2 coordinating with Beyond whitening accelerator irradiating). The shade dif-ferential (DeltaE) was calculated. ANOVA, paired t-test, and Pearson correlation analysis were used for data analysis. The efficacy rates of tooth bleaching were satisfactory, with 86.6%, 86.6%, and 85.1% in the cervical, body, and incisal sites, respectively. The average values of DeltaE were 5.09, 4.44, and 4.40 in the cervical, body, and incisal sites. Tooth bleaching significantly increased L* and significantly decreased a* and b* in all tooth areas (P spectrophotometer could objectively evaluate the whitening effect of tooth bleaching at the different tooth sites. The tooth bleaching system (35%H202 coordinating with Beyond whitening accelerator irradiating) exerts powerful bleaching actions in most of the tooth areas investigated. The order of tooth bleaching effectiveness is cervicalbody>incisal. Yellow coloration is decreased mainly at the cervical site, and brightness was increased mostly at theincisal site. The effectiveness of tooth bleaching increases as the baseline b* value increases.

  11. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  12. Aberration Correction in the Brewer Spectrophotometer

    International Nuclear Information System (INIS)

    Johnston, J.E.; Kerr, J.B.; McElroy, C.T.; Wardle, D.I.

    2000-01-01

    The optical design of the Brewer Spectrophotometer has been optimised for measurements in the 300-320 nm wavelength range. An aberration resolution limit that is much less than the 0.6 nm FWHM (full width at half maximum) is achieved by using an Ebert-Fastie spectrometer design, modified by the inclusion tilted lens that optimises performance at 310 nm. The small contribution of the remaining aberration to the measured instrument function is critical to radiometric measurement quality. Ramifications of this design to the development of instrumentation with enhanced scanning abilities are discussed. (author)

  13. Far-infrared spectrophotometer for astronomical observations

    Science.gov (United States)

    Moseley, H.; Silverberg, R. F.

    1981-01-01

    A liquid-helium-cooled far infrared spectrophotometer was built and used to make low resolution observations of the continua of several kinds of astronomical objects using the Kuiper Airborne Observatory. This instrument fills a gap in both sensitivity to continuum sources and spectral resolution between the broadband photometers with lambda/Delta lambda approximately 1 and spectrometers with lambda/Delta lambda greater than 50. While designed primarily to study planetary nebulae, the instrument permits study of the shape of the continua of many weak sources which cannot easily be observed with high resolution systems.

  14. Last improvements of the DTC 1000 spectrophotometer

    International Nuclear Information System (INIS)

    Blanc, F.

    1988-01-01

    The DTC 1000 spectrophotometer, based on optical fibers and photodiode array was developed for Pu(IV) measurement in fuel reprocessing. The apparatus takes advantage of experience acquired in optical fibers instrumentation and of the study of gamma radiation effects on fibers. This paper give the complete evolution of these last months (memory, hardware, software, background noise). But the principle of the apparatus and examples of results obtained on americium and plutonium on a previous version of the apparatus are recalled. 17 figs., 6 refs [fr

  15. Automated spectrophotometer for plutonium and uranium determination

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hodgkins, D.J.; Hollen, R.M.; Rein, J.E.

    1975-09-01

    The automated spectrophotometer described is the first in a planned series of automated instruments for determining plutonium and uranium in nuclear fuel cycle materials. It has a throughput rate of 5 min per sample and uses a highly specific method of analysis for these elements. The range of plutonium and uranium measured is 0.5 to 14 mg and 1 to 14 mg, respectively, in 0.5 ml or less of solution with an option to pre-evaporate larger volumes. The precision of the measurements is about 0.02 mg standard deviation over the range corresponding to about 2 rel percent at the 1-mg level and 0.2 rel percent at the 10-mg level. The method of analysis involves the extraction of tetrapropylammonium plutonyl and uranyl trinitrate complexes into 2-nitropropane and the measurement of the optical absorbances in the organic phase at unique peak wavelengths. Various aspects of the chemistry associated with the method are presented. The automated spectrophotometer features a turntable that rotates as many as 24 samples in tubes to a series of stations for the sequential chemical operations of reagent addition and phase mixing to effect extraction, and then to a station for the absorbance measurement. With this system, the complications of sample transfers and flow-through cells are avoided. The absorbance measurement system features highly stable interference filters and a microcomputer that controls the timing sequence and operation of the system components. Output is a paper tape printout of three numbers: a four-digit number proportional to the quantity of plutonium or uranium, a two-digit number that designates the position of the tube in the turntable, and a one-digit number that designates whether plutonium or uranium was determined. Details of the mechanical and electrical components of the instrument and of the hardware and software aspects of the computerized control system are provided

  16. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Science.gov (United States)

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  17. Assessment of groundwater potential of the crystalline basement of Wadi-Fira (Eastern Chad) using a multi-criteria correlation analysis and Remote Sensing data

    Science.gov (United States)

    Brahim Mahamat, Hamza; Coz Mathieu, Le; Abderamane, Hamit; Razack, Moumtaz

    2017-04-01

    Access to water in the Wadi-Fira aquifer system is a crucial problem in Eastern Chad because of (i) the complexity of the hydrogeological context (fractured basement), (ii) large extent of the study area (50,000 km2); And (iii) hard-to-access field data (only 34 water points were available to determine physicochemical and hydrodynamic parameters) often associated with high uncertainty. This groundwater resource is paramount in this arid environment, to meet the water needs of an increasingly growing population (refugees from Darfur) with a predominant pastoral activity. In order to optimally exploit the available data, correlative analyzes are carried out by integrating the spatial dimension of the data with GIS tools. A three-step strategy is thus implemented, based on: (i) point field data with physicochemical and hydrodynamic parameters; (ii) maps interpolated from point data, to increase the number of ''comparable'' parameters for each site; and (iii) interpolated maps coupled to maps from Remote Sensing results describing the area's structural geomorphology (slopes, hydrographic network, faults). The first results show marked correlations between physico-chemical and hydrodynamical parameters. According to the correlation matrix, the static level correlates significantly with the dominant cations (Ca2+ ; R = 0.52) and anions (HCO3- ; R = 0.53). Correlations are lower between electrical conductivity and transmissivity, and electrical conductivity and measured static level. A negative correlation is observed between Fluorine and transmissivity (r = -0.65), and the altered horizon (r = -0.5). The most significant discharges are obtained in fissured horizons. The correlative analysis allowsto differentiate mapped sectors according to the productivity and chemical quality regarding groundwater resource. Keywords: Hydrodynamics, Hydrochemistry, Remote Sensing, SRTM, Basement aquifer, Alteration, Lineaments, Wadi-Fira, Tchad.

  18. Development of a new reference spectrophotometer

    International Nuclear Information System (INIS)

    Zwinkels, J.C.; Gignac, D.S.

    1989-01-01

    A new reference spectrophotometer is being developed at the National Research Council of Canada (NRCC) for high-accuracy transmittance measurements over the spectral range 200 to 250 nm. This computerized instrument is a single-beam design based upon a servomotor-driven double monochromator with a wavelength resolution of 0.022 nm. The other main components are: two interchangeable sources (deuterium and tungsten-halogen), two computer-selectable TE-cooled detectors (GaAs photomultiplier tube and PbS cell), all-reflective input and exit optics, and a large sample compartment. The significant feature of the optical system is a large, well-collimated measurement beam: the angle of convergence is 0.7 degrees for a slit height of 7 mm, and the maximal beam size is 37 x 20 mm. This beam geometry eliminates the need for polarization corrections (using linearly polarized light) or compensation for spatially non-uniform detector responsivity (using averaging sphere). The paper describes the instrument design and presents data from preliminary performance tests. The systematic and random sources of error that have been investigated include: wavelength accuracy and reproducibility, bandpass, beam uniformity, polarization, stray light, system drift and linearity

  19. A UV-Vis photoacoustic spectrophotometer.

    Science.gov (United States)

    Wiegand, Joseph R; Mathews, L Dalila; Smith, Geoffrey D

    2014-06-17

    A novel photoacoustic spectrophotometer (PAS) for the measurement of gas-phase and aerosol absorption over the UV-visible region of the spectrum is described. Light from a broadband Hg arc lamp is filtered in eight separate bands from 300 to 700 nm using bandpass interference filters (centered at 301 nm, 314 nm, 364 nm, 405 nm, 436 nm, 546 nm, 578 and 687 nm) and modulated with an optical chopper before entering the photoacoustic cell. All wavelength bands feature a 20-s detection limit of better than 3.0 Mm(-1) with the exception of the lower-intensity 687 nm band for which it is 10.2 Mm(-1). Validation measurements of gas-phase acetone and nigrosin aerosol absorption cross sections at several wavelengths demonstrate agreement to within 10% with those measured previously (for acetone) and those predicted by Mie theory (for nigrosin). The PAS instrument is used to measure the UV-visible absorption spectrum of ambient aerosol demonstrating a dramatic increase in the UV region with absorption increasing by 300% from 405 to 301 nm. This type of measurement throughout the UV-visible region and free from artifacts associated with filter-based methods has not been possible previously, and we demonstrate its promise for classifying and quantifying different types of light-absorbing ambient particles.

  20. AESoP: Astronomical Extinction Spectrophotometer

    Science.gov (United States)

    Linford, Justin; McGraw, J.; Zimmer, P.; Ackermann, M.; Fitch, J.

    2009-01-01

    The Earth's atmosphere is a major obstruction to the precision and accuracy of ground-based photometry. The atmosphere removes light from astronomical objects both by absorption and scattering by constituent molecules, aerosols and clouds. These effects can change significantly over short time periods and over modest angles on the sky. To further understand these effects, the UNM Measurement Astrophysics Group has designed, built and recently deployed the Astronomical Extinction Spectrophotometer (AESoP), a 100mm objective grating spectrometer. By monitoring bright stars in sensibly the same direction as a larger photometric telescope is observing, AESoP will measure the wavelength-dependent extinction due to the Earth's atmosphere from 450nm to 900nm on time scales of approximately one minute. The collocated Astronomical LIDAR for Extinction (ALE) provides a high-precision monochromatic extinction measurement at 527nm. Knowing the extinction at a single wavelength allows us to pin the relative spectra generated by AESoP. These extinction spectra can then be integrated over the bandpass of the photometric telescope system to create real time corrections of observations. We present the design and construction of AESoP along with the preliminary results of our first combined observing campaign. This effort is our first step toward breaking the 1% photometry barrier. This project is funded by AFRL Grant FA9451-04-2-0355

  1. A comparison between a tristimulus colorimeter (Minolta ChromaMeter CR-200) and two spectrophotometers (Minolta Spectrophotometer CM-508i and CM-2002). Quantification of UV-B induced erythema in a hairless guinea pig model.

    Science.gov (United States)

    Fullerton, A; Keiding, J

    1997-11-01

    A comparison was made between a tristimulus colorimeter (Minolta ChromaMeter CR 200) and two spectrophotometers (Minolta CM-508i and CM-2002). The object was to compare skin colour data in the CIE 1976 L*a*d*colour space system obtained with the different instruments after UV-B exposure. Guinea pigs were exposed on their dorsal trunk with UV-B light for different time periods. Skin colour in the L*a*b* system was measured 6 and 24 h after exposure. Reproducible and objective measurements expressed in the CIE system were obtained with all three instruments. A strong correlation was found between the Minolta Chromameter CR200 and each of the two spectrophotometers. However, absolute values found with the Minolta ChromaMeter CR 200, especially for b*, differed from values obtained with the two spectrophotometers. The instruments were, despite minor inter-instrumental variation, suited for objective evaluation of erythema. The spectrophotometers were somewhat cumbersome to use due to their heavy weight and difficulties in positioning within the test sites; the Minolta CromaMeter CR200 (or later versions) is thus preferable for simple routine measurements. Use of the spectophotometers appears only indicated where specific information about skin pigments or photoactive substances relative to wavelength is needed.

  2. Cuvette and method for measuring refractive index in a spectrophotometer

    DEFF Research Database (Denmark)

    2017-01-01

    Embodiments of the present invention include a cuvette (100) for use in determining a refractive index of a sample matter in a spectrophotometer (600), the cuvette comprising a container (102) for holding the sample matter, the container (102) having an entry window (121) that allows input...... or integrally formed in the container and arranged in the radiation path, the photonic crystal having a grating part (111) causing a reflectance spectrum of the photonic crystal to exhibit a resonance. A spectrophotometer is also provided....

  3. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  4. Satellite spectrophotometer for research of the atmospheric ozone

    International Nuclear Information System (INIS)

    Getzov, P.; Mardirossian, G.; Stoyanov, S.

    2014-01-01

    The measurement of atmospheric ozone and its influence upon climate and life on Earth is undoubtedly one of the most pressing issues of present time. A mathematical model of an optical tract of a spectrophotometer has been designed. The paper presents the functional scheme of a satellite optoelectronic spectrophotometer for measuring the total content of atmospheric ozone and other gas components of the atmosphere, which has increased precision, smaller weight and energy consumption, increased space and time resolution, quickness of reaction and increased volume of useful information. The object of the paper is the design of an appliance which ensures research of ozone content in atmosphere from the board of a satellite

  5. Structure analysis of biomolecules using synchrotron radiation circular dichroism spectrophotometer

    International Nuclear Information System (INIS)

    Gekko, Kunihiko; Matsuo, Koichi

    2004-01-01

    We constructed the vacuum-ultraviolet circular dichroism (VUVCD) spectrophotometer, which is capable of measuring circular dichroism spectra to 140 nm for aqueous solutions at temperature from -30 to 70degC, using a small-scale SR source at Hiroshima Synchrotron Radiation Center (HiSOR). This spectrophotometer was used for structural analyses of amino acids, saccharides, and proteins in water. The obtained results demonstrate that a synchrotron radiation VUVCD spectroscopy provides more detailed and new information on the structures of biomolecules, based on the high energy transitions of chromophores such as hydroxyl, acetal, and peptide groups. (author)

  6. Results of laboratory tests of the information-measurement system of the five-channel spectrophotometer

    International Nuclear Information System (INIS)

    Bukach, A.B.

    1979-01-01

    The study of technical characteristics of the five-channel spectrophotometer detecting star spectra in the 3125-8570 A range was carried out. The optimal conditions of photomultipliers and amplifiers allow to count statistically distributed pulses with the time resolution up to 50 ns. Detection, with printing and perforation, of the pulses rate has the absolute error of about +- 1 pulse, when the counting rate changes from 100 to 10 4 s -1 . The step-motor system and the scanning mechanism give the spectral line position with an accuracy of +- 0.2 step (+- 2 Mcm, i.e. 0.03 A for the first order of grating). Instrumental profile effect on the line position is investigated and the dispersion curves are obtained

  7. SphinX soft X-ray spectrophotometer: Science objectives, design and performance

    Science.gov (United States)

    Gburek, S.; Sylwester, J.; Kowalinski, M.; Bakala, J.; Kordylewski, Z.; Podgorski, P.; Plocieniak, S.; Siarkowski, M.; Sylwester, B.; Trzebinski, W.; Kuzin, S. V.; Pertsov, A. A.; Kotov, Yu. D.; Farnik, F.; Reale, F.; Phillips, K. J. H.

    2011-06-01

    The goals and construction details of a new design Polish-led X-ray spectrophotometer are described. The instrument is aimed to observe emission from entire solar corona and is placed as a separate block within the Russian TESIS X- and EUV complex aboard the CORONAS-PHOTON solar orbiting observatory. SphinX uses silicon PIN diode detectors for high time resolution measurements of the solar spectra in the range 0.8-15 keV. Its spectral resolution allows for discerning more than hundred separate energy bands in this range. The instrument dynamic range extends two orders of magnitude below and above these representative for GOES. The relative and absolute accuracy of spectral measurements is expected to be better than few percent, as follows from extensive ground laboratory calibrations.

  8. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. Isosbestic points in the quality control oF spectrophotometers

    International Nuclear Information System (INIS)

    Oliveira, E.M. de.

    1987-01-01

    The methodology and results of quality control of spectrophotometers are reported and the calibrating of the monochromator by isosbestic points is presented. Four colorimetric indicators are used. The absorption curves (in acid and alkaline media) and mathematic determination of the common junction point are used for indicated the isosbetic points. (M.A.C.) [pt

  10. Reliability of shade selection using an intraoral spectrophotometer.

    Science.gov (United States)

    Witkowski, Siegbert; Yajima, Nao-Daniel; Wolkewitz, Martin; Strub, Jorge R

    2012-06-01

    In this study, we evaluate the accuracy and reproducibility of human tooth shade selection using a digital spectrophotometer. Variability among examiners and illumination conditions were tested for possible influence on measurement reproducibility. Fifteen intact anterior teeth of 15 subjects were evaluated for their shade using a digital spectrophotometer (Crystaleye, Olympus, Tokyo, Japan) by two examiners under the same light conditions representing a dental laboratory situation. Each examiner performed the measurement ten times on the labial surface of each tooth containing three evaluation sides (cervical, body, incisal). Commission International on Illumination color space values for L* (lightness), a* (red/green), and b* (yellow/blue) were obtained from each evaluated side. Examiner 2 repeated the measurements of the same subjects under different light conditions (i.e., a dental unit with a chairside lamp). To describe measurement precision, the mean color difference from the mean metric was used. The computed confidence interval (CI) value 5.228 (4.6598-5.8615) reflected (represented) the validity of the measurements. Least square mean analysis of the values obtained by examiners 1 and 2 or under different illumination conditions revealed no statistically significant differences (CI = 95%). Within the limits of the present study, the accuracy and reproducibility of dental shade selection using the tested spectrophotometer with respect to examiner and illumination conditions reflected the reliability of this device. This study suggests that the tested spectrophotometer can be recommended for the clinical application of shade selection.

  11. Fiber optic modification of a diode array spectrophotometer

    International Nuclear Information System (INIS)

    Van Hare, D.R.; Prather, W.S.

    1986-01-01

    Fiber optics were adapted to a Hewlett-Packard diode array spectrophotometer to permit the analysis of radioactive samples without risking contamination of the instrument. Instrument performance was not compromised by the fiber optics. The instrument is in routine use at the Savannah River Plant control laboratories

  12. Danish Towns during Absolutism

    DEFF Research Database (Denmark)

    This anthology, No. 4 in the Danish Urban Studies Series, presents in English recent significant research on Denmark's urban development during the Age of Absolutism, 1660-1848, and features 13 articles written by leading Danish urban historians. The years of Absolutism were marked by a general...

  13. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  14. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  15. Approach To Absolute Zero

    Indian Academy of Sciences (India)

    more and more difficult to remove heat as one approaches absolute zero. This is the ... A new and active branch of engineering ... This temperature is called the critical temperature, Te' For sulfur dioxide the critical ..... adsorbent charcoal.

  16. 21 CFR 862.2300 - Colorimeter, photometer, or spectrophotometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Colorimeter, photometer, or spectrophotometer for... Clinical Laboratory Instruments § 862.2300 Colorimeter, photometer, or spectrophotometer for clinical use. (a) Identification. A colorimeter, a photometer, or a spectrophotometer for clinical use is an...

  17. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and measure...

  18. Encasing the Absolutes

    Directory of Open Access Journals (Sweden)

    Uroš Martinčič

    2014-05-01

    Full Text Available The paper explores the issue of structure and case in English absolute constructions, whose subjects are deduced by several descriptive grammars as being in the nominative case due to its supposed neutrality in terms of register. This deduction is countered by systematic accounts presented within the framework of the Minimalist Program which relate the case of absolute constructions to specific grammatical factors. Each proposal is shown as an attempt of analysing absolute constructions as basic predication structures, either full clauses or small clauses. I argue in favour of the small clause approach due to its minimal reliance on transformations and unique stipulations. Furthermore, I propose that small clauses project a singular category, and show that the use of two cases in English absolute constructions can be accounted for if they are analysed as depictive phrases, possibly selected by prepositions. The case of the subject in absolutes is shown to be a result of syntactic and non-syntactic factors. I thus argue in accordance with Minimalist goals that syntactic case does not exist, attributing its role in absolutes to other mechanisms.

  19. Automated dual-wavelength spectrophotometer optimized for phytochrome assay

    International Nuclear Information System (INIS)

    Pratt, L.H.; Wampler, J.E.; Rich, E.S. Jr.

    1985-01-01

    A microcomputer-controlled dual-wavelength spectrophotometer suitable for automated phytochrome assay is described. The optomechanical unit provides for sequential irradiation of the sample by the two measuring wavelengths with intervening dark intervals and for actinic irradiation to interconvert phytochrome between its two forms. Photomultiplier current is amplified, converted to a digital value and transferred into the computer using a custom-designed IEEE-488 bus interface. The microcomputer calculates mathematically both absorbance and absorbance difference values with dynamic correction for photomultiplier dark current. In addition, the computer controls the operating parameters of the spectrophotometer via a separate interface. These parameters include control of the durations of measuring and actinic irradiation intervals and their sequence. 14 references, 4 figures

  20. Non-focusing optics spectrophotometer, and methods of use

    Science.gov (United States)

    Kramer, David M.; Sacksteder, Colette A.

    2004-11-02

    In one aspect, the present invention provides kinetic spectrophotometers that each comprise: (a) a light source; and (b) a compound parabolic concentrator disposed to receive light from the light source and configured to (1) intensify and diffuse the light received from the light source, and (2) direct the intensified and diffused light onto a sample. In other aspects, the present invention provides methods for measuring a photosynthetic parameter, the methods comprising the steps of: (a) illuminating a plant leaf until steady-state photosynthesis is achieved; (b) subjecting the illuminated plant leaf to a period of darkness; (c) using a kinetic spectrophotometer of the invention to collect spectral data from the plant leaf treated in accordance with steps (a) and (b); and (d) determining a value for a photosynthetic parameter from the spectral data.

  1. Dobson spectrophotometer ozone measurements during international ozone rocketsonde intercomparison

    Science.gov (United States)

    Parsons, C. L.

    1980-01-01

    Measurements of the total ozone content of the atmosphere, made with seven ground based instruments at a site near Wallops Island, Virginia, are discussed in terms for serving as control values with which the rocketborne sensor data products can be compared. These products are profiles of O3 concentration with altitude. By integrating over the range of altitudes from the surface to the rocket apogee and by appropriately estimating the residual ozone amount from apogee to the top of the atmosphere, a total ozone amount can be computed from the profiles that can be directly compared with the ground based instrumentation results. Dobson spectrophotometers were used for two of the ground-based instruments. Preliminary data collected during the IORI from Dobson spectrophotometers 72 and 38 are presented. The agreement between the two and the variability of total ozone overburden through the experiment period are discussed.

  2. Spectrophotometer-Integrating-Sphere System for Computing Solar Absorptance

    Science.gov (United States)

    Witte, William G., Jr.; Slemp, Wayne S.; Perry, John E., Jr.

    1991-01-01

    A commercially available ultraviolet, visible, near-infrared spectrophotometer was modified to utilize an 8-inch-diameter modified Edwards-type integrated sphere. Software was written so that the reflectance spectra could be used to obtain solar absorptance values of 1-inch-diameter specimens. A descriptions of the system, spectral reflectance, and software for calculation of solar absorptance from reflectance data are presented.

  3. Online analysis by a fiber-optic diode array spectrophotometer

    International Nuclear Information System (INIS)

    Van Hare, D.R.; Prather, W.S.; O'Rourke, P.E.

    1987-01-01

    An online photometric analyzer has been developed which can make remote measurements over the 350 to 900 nm region at distances of up to 100 feet. The analyzer consists of a commercially available diode array spectrophotometer interfaced to a fiber-optic multiplexer to allow online monitoring of up to ten locations sequentially. The development of the fiber-optic interface is discussed and data from several online applications are presented to demonstrate the capabilities of the measurement system

  4. Vacuum-ultraviolet circular dichroism spectrophotometer using synchrotron radiation

    International Nuclear Information System (INIS)

    Matsuo, K.; Fukuyama, T.; Yonehara, R.; Namatame, H.; Taniguchi, M.; Gekko, K.

    2005-01-01

    We have constructed a vacuum-ultraviolet circular dichroism (VUVCD) spectrophotometer using a synchrotron radiation and an assembled-type MgF 2 cell endurable under a high vacuum, to measure the CD spectra of biomaterials in aqueous solutions from 310 to 140 nm. To avoid the absorption of light by air and water vapor, all optical devices of the spectrophotometer were set up under a high vacuum (10 -4 Pa). A path length of the optical cell can be adjusted by various Teflon spacers in the range from 1.3 to 50 μm and its temperature can be controlled to an accuracy of ±1 deg. C over the range from -30 to 70 deg. C by a temperature-control unit using a Peltier thermoelectric element. The performance of the spectrophotometer and the optical cell constructed was tested by measuring the CD spectra of ammonium d-camphor-10-sulfonate, D- and L-isomers of amino acids, and myoglobin in aqueous solutions. The spectra obtained demonstrate that the optical system and the sample cell constructed operate normally under a high vacuum and provide useful information on the structure of biomolecules based on the higher energy chromophores

  5. Vacuum-ultraviolet circular dichroism spectrophotometer using synchrotron radiation

    International Nuclear Information System (INIS)

    Matsu, K.; Yonehara, R.; Gekko, K.

    2004-01-01

    Full text: Circular dichroism (CD) spectroscopy is powerful for analyzing the structure of optically active materials such as biopolymers. However, no commercial CD spectrophotometer is capable of measuring the CD in the vacuum ultraviolet (VUV) region below 190 nm because of technical difficulties involved in the light source, optical device, and sample cell. CD measurements extended to the VUV region can provide more detailed and new information on the structure of biopolymers based on the higher energy transition of chromophores such as hydroxyl and acetal groups. We have constructed a VUVCD spectrophotometer to measure the CD spectra of biomaterials in aqueous solutions in the 310-140 nm wavelength region under a high vacuum, using a small-scale SR source (0.7 GeV) at Hiroshima Synchrotron Radiation Center (HiSOR). All optical devices of the spectrophotometer were set up under a high vacuum (10 -6 Torr), to avoid the absorption of light by air and water vapor. The SR light is separated into two orthogonal linearly polarized light beams by a linear polarizer and then modulated to circularly polarized light at 50 kHz by a photo-elastic modulator (PEM). In order to control PEM accurately and to stabilize the lock-in amplifier under a high vacuum, we used the optical servo-control system. Also, an assembled-type MgF 2 cell with a temperature-control unit was constructed using a Peltier thermoelectric element. Its path length can be adjusted by various Tefron spacers in the range from 1.3 to 50 μm and its temperature can be controlled within an accuracy of ± 1 deg C in the range from -30 to 70 deg C. The performance of the spectrophotometer and MgF 2 cell constructed was tested by monitoring the CD spectra of ammonium d-camphor-10-sulfonate (ACS), D- and L-isomers of amino acids. These obtained results demonstrate that the optical system and the sample cell constructed normally operate under a high vacuum to provide useful information on the structure analysis of

  6. [In vivo model to evaluate the accuracy of complete-tooth spectrophotometer for dental clinics].

    Science.gov (United States)

    Liu, Feng; Yang, Jian; Xu, Tong-Kai; Xu, Ming-Ming; Ma, Yu

    2011-02-01

    To test ΔE between measured value and right value from the Crystaleye complete-tooth spectrophotometer, and to evaluate the accuracy rate of the spectrophotometer. Twenty prosthodontists participated in the study. Each of them used Vita 3D-Master shadeguide to do the shade matching, and used Crystaleye complete-tooth spectrophotometer (before and after the test training) tested the middle of eight fixed tabs from shadeguide in the dark box. The results of shade matching and spectrophotometer were recorded. The accuracy rate of shade matching and the spectrophotometer before and after training were calculated. The average accuracy rate of shade matching was 49%. The average accuracy rate of the spectrophotometer before and after training was 83% and 99%. The accuracy of the spectrophotometer was significant higher than that in shade matching, and training can improve the accuracy rate.

  7. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  8. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  9. Automated atomic absorption spectrophotometer, utilizing a programmable desk calculator

    International Nuclear Information System (INIS)

    Futrell, T.L.; Morrow, R.W.

    1977-01-01

    A commercial, double-beam atomic absorption spectrophotometer has been interfaced with a sample changer and a Hewlett-Packard 9810A calculator to yield a completely automated analysis system. The interface electronics can be easily constructed and should be adaptable to any double-beam atomic absorption instrument. The calculator is easily programmed and can be used for general laboratory purposes when not operating the instrument. The automated system has been shown to perform very satisfactorily when operated unattended to analyze a large number of samples. Performance statistics agree well with a manually operated instrument

  10. Ultraviolet spectrophotometer for measuring columnar atmospheric ozone from aircraft

    Science.gov (United States)

    Hanser, F. A.; Sellers, B.; Briehl, D. C.

    1978-01-01

    An ultraviolet spectrophotometer (UVS) to measure downward solar fluxes from an aircraft or other high altitude platform is described. The UVS uses an ultraviolet diffuser to obtain large angular response with no aiming requirement, a twelve-position filter wheel with narrow (2-nm) and broad (20-nm) bandpass filters, and an ultraviolet photodiode. The columnar atmospheric ozone above the UVS (aircraft) is calculated from the ratios of the measured ultraviolet fluxes. Comparison with some Dobson station measurements gives agreement to 2%. Some UVS measured ozone profiles over the Pacific Ocean for November 1976 are shown to illustrate the instrument's performance.

  11. UV-observations with a Brewer spectrophotometer at Hohenpeissenberg

    Science.gov (United States)

    Vandersee, Winfried; Koehler, U.

    1994-01-01

    Regular spectral UV-B measurements with a Brewer spectrophotometer have been performed at Hohenpeissenberg since 1990. Intercomparison of the Brewer instrument with other UV-B monitoring devices have shown agreement to within plus or minus 10 percent. Comparisons of UV-B spectra measured on fair weather days reveal the well known increasing influence of ozone on UV-B irradiance with decreasing wavelengths. The integral amplification factor the erythemal irradiance reaches values up to 2.8, which can be diminished by increasing turbidity. The influence of cirrus cloud on the UV-B is also shown.

  12. Simple LED spectrophotometer for analysis of color information.

    Science.gov (United States)

    Kim, Ji-Sun; Kim, A-Hee; Oh, Han-Byeol; Goh, Bong-Jun; Lee, Eun-Suk; Kim, Jun-Sik; Jung, Gu-In; Baek, Jin-Young; Jun, Jae-Hoon

    2015-01-01

    A spectrophotometer is the basic measuring equipment essential to most research activity fields requiring samples to be measured, such as physics, biotechnology and food engineering. This paper proposes a system that is able to detect sample concentration and color information by using LED and color sensor. Purity and wavelength information can be detected by CIE diagram, and the concentration can be estimated with purity information. This method is more economical and efficient than existing spectrophotometry, and can also be used by ordinary persons. This contribution is applicable to a number of fields because it can be used as a colorimeter to detect the wavelength and purity of samples.

  13. Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.

    2017-09-01

    The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.

  14. Effekten af absolut kumulation

    DEFF Research Database (Denmark)

    Kyvsgaard, Britta; Klement, Christian

    2012-01-01

    Som led i finansloven for 2011 blev regeringen og forligspartierne enige om at undersøge reglerne om strafudmåling ved samtidig pådømmelse af flere kriminelle forhold og i forbindelse hermed vurdere konsekvenserne af at ændre de gældende regler i forhold til kapacitetsbehovet i Kriminalforsorgens...... samlet bødesum ved en absolut kumulation i forhold til en modereret kumulation, som nu er gældende....

  15. Results of international Dobson spectrophotometer calibrations at Arosa, Switzerland, 1990

    Science.gov (United States)

    Grass, R. D.; Komhyr, W. D.; Koenig, G. L.; Evans, R. D.

    1994-01-01

    An international comparison of Dobson ozone spectrophotometers, organized and partially funded by the World Meteorological Organization (WMO), was held at the Lichtklimatisches Observatorium (LKO) in Arosa, Switzerland, July-August 1990. Countries participating with a total of 18 Dobson instruments were Belgium, Czechoslovakia, Denmark, Germany, Greece, Hungary, Iceland, Norway, Poland, Portugal, Rumania, Spain, Switzerland, the United Kingdom, the United States, and the United Soviet Socialist Republics. The reference standard instrument for the comparison was U.S.A. Secondary Standard Dobson Spectrophotometer 65 maintained by the NOAA Climate and Monitoring and Diagnostics Laboratory, Boulder, Colorado. The mean difference in ozone obtained with the Dobson instruments relative to Dobson instrument 65, calculated from ADDSGQP observations in the air mass range 1.15-3.2, was minus 1.0 plus or minus 1.2 (1 sigma) percent. The WMO Standard Brewer Spectrometer 39 also participated. In the mean, the Brewer instrument measured 0.6 plus or minus 0.2 (1 sigma) percent more ozone than did Dobson instrument 65. Results are presented, also, of ozone vertical profile measurements made with the Dobson instruments, two Brewer spectrometers, a LIDAR, a balloon ozonesonde flown from Hohenpeissenberg, Germany, and balloon ozonesondes flown from Payerne, Switzerland.

  16. Portable visible and near-infrared spectrophotometer for triglyceride measurements.

    Science.gov (United States)

    Kobayashi, Takanori; Kato, Yukiko Hakariya; Tsukamoto, Megumi; Ikuta, Kazuyoshi; Sakudo, Akikazu

    2009-01-01

    An affordable and portable machine is required for the practical use of visible and near-infrared (Vis-NIR) spectroscopy. A portable fruit tester comprising a Vis-NIR spectrophotometer was modified for use in the transmittance mode and employed to quantify triglyceride levels in serum in combination with a chemometric analysis. Transmittance spectra collected in the 600- to 1100-nm region were subjected to a partial least-squares regression analysis and leave-out cross-validation to develop a chemometrics model for predicting triglyceride concentrations in serum. The model yielded a coefficient of determination in cross-validation (R2VAL) of 0.7831 with a standard error of cross-validation (SECV) of 43.68 mg/dl. The detection limit of the model was 148.79 mg/dl. Furthermore, masked samples predicted by the model yielded a coefficient of determination in prediction (R2PRED) of 0.6856 with a standard error of prediction (SEP) and detection limit of 61.54 and 159.38 mg/dl, respectively. The portable Vis-NIR spectrophotometer may prove convenient for the measurement of triglyceride concentrations in serum, although before practical use there remain obstacles, which are discussed.

  17. [A micro-silicon multi-slit spectrophotometer based on MEMS technology].

    Science.gov (United States)

    Hao, Peng; Wu, Yi-Hui; Zhang, Ping; Liu, Yong-Shun; Zhang, Ke; Li, Hai-Wen

    2009-06-01

    A new mini-spectrophotometer was developed by adopting micro-silicon slit and pixel segmentation technology, and this spectrophotometer used photoelectron diode array as the detector by the back-dividing-light way. At first, the effect of the spectral bandwidth on the tested absorbance linear correlation was analyzed. A theory for the design of spectrophotometer's slit was brought forward after discussing the relationships between spectrophotometer spectrum band width and pre-and post-slits width. Then, the integrative micro-silicon-slit, which features small volume, high precision, and thin thickness, was manufactured based on the MEMS technology. Finally, a test was carried on linear absorbance solution by this spectrophotometer. The final result showed that the correlation coefficients were larger than 0.999, which means that the new mini-spectrophotometer with micro-silicon slit pixel segmentation has an obvious linear correlation.

  18. Towards absolute neutrino masses

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory 106-38, Caltech, Pasadena, CA 91125 (United States)

    2007-06-15

    Various ways of determining the absolute neutrino masses are briefly reviewed and their sensitivities compared. The apparent tension between the announced but unconfirmed observation of the 0{nu}{beta}{beta} decay and the neutrino mass upper limit based on observational cosmology is used as an example of what could happen eventually. The possibility of a 'nonstandard' mechanism of the 0{nu}{beta}{beta} decay is stressed and the ways of deciding which of the possible mechanisms is actually operational are described. The importance of the 0{nu}{beta}{beta} nuclear matrix elements is discussed and their uncertainty estimated.

  19. PC based data system for infrared spectrophotometer PU-9512

    International Nuclear Information System (INIS)

    Ali, Mohd Yakub; Venkiteswaran, S.; Nagar, M.S.

    2000-08-01

    This report summarises the upgrading of an old Infra Red Spectrophotometer using a pc for control, data acquisition, storage and analysis. The hardware link is made through RS232C serial port. The control and data management is achieved through software. A brief account of the facilities provided and versatility of the analysis package which was developed in-house in a user friendly menu driven fashion is given here. This is supported by the analysis and inter comparison of infra red spectra of organic/inorganic reactants and products. It has specific application in synthesis and characterization of new extractants, solvents, actinide and lanthanide complexes and in the study of thermally and radiolytically degraded products. (author)

  20. Estimation of total alkaloid in Chitrakadivati by UV-Spectrophotometer.

    Science.gov (United States)

    Ajanal, Manjunath; Gundkalle, Mahadev B; Nayak, Shradda U

    2012-04-01

    Herbal formulation standardization by adopting newer technique is need of the hour in the field of Ayurvedic pharmaceutical industry. As very few reports exist. These kind of studies would certainly widen the herbal research area. Chitrakadivati is one such popular herbal formulation used in Ayurveda. Many of its ingredients are known for presence of alkaloids. Presence of alkaloid was tested qualitatively by Dragondroff's method then subjected to quantitative estimation by UV-Spectrophotometer. This method is based on the reaction between alkaloid and bromocresol green (BCG). Study discloses that out of 16 ingredients, 9 contain alkaloid. Chitrakadivati has shown 0.16% of concentration of alkaloid and which is significantly higher than it's individual ingredients.

  1. RECALIBRATION OF H CANYON ONLINE SPECTROPHOTOMETER AT EXTENDED URANIUM CONCENTRATION

    International Nuclear Information System (INIS)

    Lascola, R

    2008-01-01

    The H Canyon online spectrophotometers are calibrated for measurement of the uranium and nitric acid concentrations of several tanks in the 2nd Uranium Cycle.[1] The spectrometers, flow cells, and prediction models are currently optimized for a process in which uranium concentrations are expected to range from 0-15 g/L and nitric acid concentrations from 0.05-6 M. However, an upcoming processing campaign will involve 'Super Kukla' material, which has a lower than usual enrichment of fissionable uranium. Total uranium concentrations will be higher, spanning approximately 0-30 g/L U, with no change in the nitric acid concentrations. The new processing conditions require the installation of new flow cells with shorter path lengths. As the process solutions have a higher uranium concentration, the shorter path length is required to decrease the absorptivity to values closer to the optimal range for the instrument. Also, new uranium and nitric acid prediction models are required to span the extended uranium concentration range. The models will be developed for the 17.5 and 15.4 tanks, for which nitric acid concentrations will not exceed 1 M. The restricted acid range compared to the original models is anticipated to reduce the measurement uncertainty for both uranium and nitric acid. The online spectrophotometers in H Canyon Second Uranium Cycle were modified to allow measurement of uranium and nitric acid for the Super Kukla processing campaign. The expected uranium concentrations, which are higher than those that have been recently processed, required new flow cells with one-third the optical path length of the existing cells. Also, new uranium and nitric acid calibrations were made. The estimated reading uncertainties (2σ) for Tanks 15.4 and 17.5 are ∼5% for uranium and ∼25% for nitric acid

  2. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  3. Absolute Gravimetry in Fennoscandia

    DEFF Research Database (Denmark)

    Pettersen, B. R; TImmen, L.; Gitlein, O.

    The Fennoscandian postglacial uplift has been mapped geometrically using precise levelling, tide gauges, and networks of permanent GPS stations. The results identify major uplift rates at sites located around the northern part of the Gulf of Bothnia. The vertical motions decay in all directions...... motions) has its major axis in the direction of southwest to northeast and covers a distance of about 2000 km. Absolute gravimetry was made in Finland and Norway in 1976 with a rise-and fall instrument. A decade later the number of gravity stations was expanded by JILAg-5, in Finland from 1988, in Norway...... time series of several years are now available. Along the coast there are nearby tide gauge stations, many of which have time series of several decades. We describe the observing network, procedures, auxiliary observations, and discuss results obtained for selected sites. We compare the gravity results...

  4. Compensation for the temperature drift of the wavelength adjustment in an acoustooptic spectrophotometer

    International Nuclear Information System (INIS)

    Vilenskii, A V; Lysoi, B G; Cherednichenko, O B

    2002-01-01

    It is shown that the temperature drift of the wavelength adjustment in acoustooptic spectrophotometers can be compensated by using the reference channel of the spectrophotometer in which the absorption lines of neodymium-doped yttrium - aluminium garnet are employed as reference lines.

  5. The Spectrophotometer II: A Module on the Spectral Properties of Light. Tech Physics Series.

    Science.gov (United States)

    Frank, Nathaniel; And Others

    This module is designed to give the learner an understanding of the nature of light and how its properties are used in the design of spectrophotometers. Problems promote the use of spectrophotometers in qualitative analysis, the optical elements used in a monochromator, and the physical properties of the prism and the diffraction grating. Other…

  6. COBE: A Radiological Analysis

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2009-10-01

    Full Text Available The COBE Far Infrared Absolute Spectrophotometer (FIRAS operated from ~30 to ~3,000 GHz (1-95 cm$^{-1}$ and monitored, from polar orbit (~900 km, the ~3 K microwave background. Data released from FIRAS has been met with nearly universal admiration. However, a thorough review of the literature reveals significant problems with this instrument. FIRAS was designed to function as a differential radiometer, wherein the sky signal could be nulled by the reference horn, Ical. The null point occurred at an Ical temperature of 2.759 K. This was 34 mK above the reported sky temperature, 2.725$pm$0.001 K, a value where the null should ideally have formed. In addition, an 18 mK error existed between the thermometers in Ical, along with a drift in temperature of ~3 mK. A 5 mK error could be attributed to Xcal; while a 4 mK error was found in the frequency scale. A direct treatment of all these systematic errors would lead to a ~64 mK error bar in the microwave background temperature. The FIRAS team reported ~1 mK, despite the presence of such systematic errors. But a 1 mK error does not properly reflect the experimental state of this spectrophotometer. In the end, all errors were essentially transferred into the calibration files, giving the appearance of better performance than actually obtained. The use of calibration procedures resulted in calculated Ical emissivities exceeding 1.3 at the higher frequencies, whereas an emissivity of 1 constitutes the theoretical limit. While data from 30-60 GHz was once presented, these critical points are later dropped, without appropriate discussion, presumably because they reflect too much microwave power. Data obtained while the Earth was directly illuminating the sky antenna, was also discarded. From 300-660 GHz, initial FIRAS data had systematically growing residuals as frequencies increased. This suggested that the signal was falling too quickly in the Wien region of the spectrum. In later data releases, the

  7. Bulk and track etching of PET studied by spectrophotometer

    International Nuclear Information System (INIS)

    Zhu, Z.Y.; Duan, J.L.; Maekawa, Y.; Koshikawa, H.; Yoshida, M.

    2004-01-01

    UV-VIS spectra of poly(ethylene terephthalate) (PET) solutions formed by etching PET in NaOH solution were analyzed with respect to the etching time. A linear relationship between absorptions centered at 4.45 and 5.11 eV with weight loss of PET in NaOH solution was established. The relation was applied to study the influence of UV light illumination on bulk etching of PET and to evaluate pore size of etched-through tracks. It is found that bulk etching of PET can be greatly enhanced by UV illumination in air in the wavelength range around 313 nm. A surface area of about 350 nm in thickness shows a 23 times increase in bulk-etching rate after illuminated for 6 h. The phenomenon is attributed to the oxygen-assisted photo-degradation through generating of new photo-unstable species. The enhancement in bulk etching was immediately reduced as the etching proceeds below the surface with an exponential decay constant of about 1.5 μm -1 . Etching of Xe ion irradiated PET films gives extra etching products with similar chemical structure as revealed by spectrophotometer measurements. Quantitative analysis of etching products from latent tracks implies that pores of about 14.6 nm in radius are formed after etching in 0.74 N NaOH at 40 deg. C for 35 min, which is in agreement with the conductometric measurement

  8. Comparation studies of uranium analysis method using spectrophotometer and voltammeter

    International Nuclear Information System (INIS)

    Sugeng Pomomo

    2013-01-01

    Comparation studies of uranium analysis method by spectrophotometer and voltammeter had been done. The objective of experiment is to examine the reliability of analysis method and instrument performance by evaluate parameters; linearity, accuracy, precision and detection limit. Uranyl nitrate hexahydrate is used as standard, and the sample is solvent mixture of tributyl phosphate and kerosene containing uranium (from phosphoric acid purification unit Petrokimia Gresik). Uranium (U) stripping in the sample use HN0 3 0,5 N and then was analyzed by using of both instrument. Analysis of standard show that both methods give a good linearity by correlation coefficient > 0,999. Spectrophotometry give accuration 99,34 - 101,05 % with ratio standard deviation (RSD) 1,03 %; detection limit (DL) 0,05 ppm. Voltammetry give accuration 95,63 -101,49 % with RSD 3,91 %; detection limit (DL) 0,509 ppm. On the analysis of sludge samples were given the significantly different in result; spectrophotometry give U concentration 4,445 ppm by RSD 6,74 % and voltammetry give U concentration 7,693 by RSD 19,53%. (author)

  9. PHASES: a concept for a satellite-borne ultra-precise spectrophotometer

    International Nuclear Information System (INIS)

    Burgo, C del; Prieto, C Allende; Peacocke, T

    2010-01-01

    The Planet Hunting and Asteroseismology Explorer Spectrophotometer, PHASES, is a concept for a space-borne instrument to obtain flux calibrated spectra and measure micro-magnitude photometric variations of nearby stars. The science drivers are the determination of the physical properties of stars and the characterisation of planets orbiting them, to very high precision. PHASES, intended to be housed in a micro-satellite, consists of a 20 cm aperture modified Baker telescope feeding two detectors: the tracking detector, with a field of 1 degree square, and the science detector for performing spectrophotometry. The optical design has been developed with the primary goal of avoiding stray light on the science detector, while providing spectra in the wavelength range 370-960 nm with a resolving power that ranges from ∼ 900 at 370 nm to ∼ 200 at 960 nm. The signal to noise per resolution element obtained for a V = 10 magnitude star in a 1 minute integration varies between ∼ 35 and 140. An analysis of the light curve constrains the radii of the planets relative to their parent stars' radii, which are, in turn, tightly constrained by the combination of absolute spectrophotometry and trigonometric parallaxes. The provisional optical design satisfies all the scientific requirements, including a ∼ 1% rms flux calibration strategy based on observations of bright A-type stars and model atmospheres, allowing the determination of stellar angular diameters for nearby solar-like stars to 0.5%. This level of accuracy will be propagated to the stellar radii for the nearest stars, with highly reliable Hipparcos parallaxes, and more significantly, to the planetary radii.

  10. Absolute risk, absolute risk reduction and relative risk

    Directory of Open Access Journals (Sweden)

    Jose Andres Calvache

    2012-12-01

    Full Text Available This article illustrates the epidemiological concepts of absolute risk, absolute risk reduction and relative risk through a clinical example. In addition, it emphasizes the usefulness of these concepts in clinical practice, clinical research and health decision-making process.

  11. Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.

    Science.gov (United States)

    Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin

    2012-10-01

    An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.

  12. Projective absoluteness for Sacks forcing

    NARCIS (Netherlands)

    Ikegami, D.

    2009-01-01

    We show that Sigma(1)(3)-absoluteness for Sacks forcing is equivalent to the nonexistence of a Delta(1)(2) Bernstein set. We also show that Sacks forcing is the weakest forcing notion among all of the preorders that add a new real with respect to Sigma(1)(3) forcing absoluteness.

  13. Skin color analysis using a spectrophotometer in Asians.

    Science.gov (United States)

    Yun, In Sik; Lee, Won Jai; Rah, Dong Kyun; Kim, Yong Oock; Park, Be-young Yun

    2010-08-01

    To objectively describe skin color, the Commission International d'Eclairage (CIE) L*a*b* color coordinates and melanin and erythema indexes are used. However, it was difficult to understand the relationship among these parameters and to convert them into each other. We introduced a new technique to measure L*a*b* color coordinates and the melanin and erythema indexes at the same time. We analyzed the skin color of normal Asians using this method. The skin color of the forehead, cheek, upper inner arm, dorsum of hand, and anterior chest of 148 volunteers was measured using a spectrophotometer. Using a computer analysis program, L*a*b* values and the melanin and erythema indexes were presented at the same time. The averages of these data were shown according to gender, age, body parts, and correlations among the melanin and erythema indexes and L*a*b* color coordinates, and then they were analyzed. The averages of the melanin and erythema indexes of 148 participants were 1.10 +/- 0.29 and 1.29 +/- 0.38, respectively. The averages of the L*, a*, and b* values were 64.15 +/- 4.86, 8.96 +/- 2.65, and 18.34 +/- 2.39, respectively. The melanin and erythema indexes were higher in males than in females. While the correlation of the melanin index with the L* value was negative, it was positively correlated with the a* and b* values. While the erythema index showed a weak correlation with the b* value, its correlation was negative with the L* value and positive with the a* value. Our method of skin color measurement is useful. We consider the data of this study valuable basic data for the evaluation of colors of pigmental skin diseases and scars in the future.

  14. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  15. Determination of the Performance Parameters of a Spectrophotometer: An Advanced Experiment.

    Science.gov (United States)

    Cope, Virgil W.

    1978-01-01

    Describes an advanced analytical chemistry laboratory experiment developed for the determination of the performance parameters of a spectrophotometer. Among the parameters are the baseline linearity with wavelength, wavelength accuracy and respectability, stray light, noise level and pen response time. (HM)

  16. Fundamental studies to develop certified reference material to calibrate spectrophotometer in the ultraviolet region

    International Nuclear Information System (INIS)

    Da Conceição, F C; Borges, P P; Gomes, J F S

    2016-01-01

    Spectrophotometry is the technique used in a great number of laboratories around the world. Quantitative determination of a high number of inorganic, organic and biological species can be made by spectrophotometry using calibrated spectrophotometers. International standards require the use of optical filters to perform the calibration of spectrophotometers. One of the recommended materials is the crystalline potassium dichromate (K_2Cr_2O_7), which is used to prepare solutions in specific concentrations for calibration or verification of spectrophotometers in the ultraviolet (UV) spectral regions. This paper presents the results concerning the fundamental studies for developing a certified reference material (CRM) of crystalline potassium dichromate to be used as standard of spectrophotometers in order to contribute to reliable quantitative analyses. (paper)

  17. Evaluation of accuracy of shade selection using two spectrophotometer systems: Vita Easyshade and Degudent Shadepilot.

    Science.gov (United States)

    Kalantari, Mohammad Hassan; Ghoraishian, Seyed Ahmad; Mohaghegh, Mina

    2017-01-01

    The aim of this in vitro study was to evaluate the accuracy of shade matching using two spectrophotometric devices. Thirteen patients who require a full coverage restoration for one of their maxillary central incisors were selected while the adjacent central incisor was intact. 3 same frameworks were constructed for each tooth using computer-aided design and computer-aided manufacturing technology. Shade matching was performed using Vita Easyshade spectrophotometer, Shadepilot spectrophotometer, and Vitapan classical shade guide for the first, second, and third crown subsequently. After application, firing, and glazing of the porcelain, the color was evaluated and scored by five inspectors. Both spectrophotometric systems showed significantly better results than visual method ( P spectrophotometers ( P Spectrophotometers are a good substitute for visual color selection methods.

  18. An extinction scale-expansion unit for the Beckman DK2 spectrophotometer

    Science.gov (United States)

    Dixon, M.

    1967-01-01

    The paper describes a simple but accurate unit for the Beckman DK2 recording spectrophotometer, whereby any 0·1 section of the extinction (`absorbance') scale may be expanded tenfold, while preserving complete linearity in extinction. PMID:6048800

  19. Versatile IEEE-488 data acquisition and control routines for a diode array spectrophotometer

    OpenAIRE

    Shiundu, Paul M.; Wade, Adrian P.

    1991-01-01

    The UV-visible diode array spectrophotometer is a work-horse instrument for many laboratories. This article provides simple data acquisition and control routines in Microsoft QuickBasic for a HP-8452A diode array spectrophotometer interfaced to an IBM PC/XT/AT, or compatible, microcomputer. These allow capture of full spectra and measure absorbance at one or several wavelengths at preset time intervals. The variance in absorbance at each wavelength is available as an option.

  20. Versatile IEEE-488 data acquisition and control routines for a diode array spectrophotometer

    Science.gov (United States)

    Shiundu, Paul M.

    1991-01-01

    The UV-visible diode array spectrophotometer is a work-horse instrument for many laboratories. This article provides simple data acquisition and control routines in Microsoft QuickBasic for a HP-8452A diode array spectrophotometer interfaced to an IBM PC/XT/AT, or compatible, microcomputer. These allow capture of full spectra and measure absorbance at one or several wavelengths at preset time intervals. The variance in absorbance at each wavelength is available as an option. PMID:18924888

  1. Using a digital multimeter to capture spectral information generated by a spectrophotometer broadcast / atomic absorption

    International Nuclear Information System (INIS)

    Villalobos Chaves, Alberto E.

    2006-01-01

    Spectral analysis capability of the information generated by a spectrophotometer broadcast / shimadzu AA 640-13 atomic absorption has increased, through the capture of data, using a digital multimeter as the interface between the spectrophotometer and a computer. To facilitate the identification of analytes was created Chromulan format files for the 99 chemical elements reported in the literature, and covering the region between 200 nm and 900 nm, the subject of this study. (author) [es

  2. Cryogenic, Absolute, High Pressure Sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  3. Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®.

    Science.gov (United States)

    Odaira, Chikayuki; Itoh, Sozo; Ishibashi, Kanji

    2011-10-01

    To evaluate the clinical performance of the Crystaleye Spectrophotometer(®), a dental color analysis system. Three color-measuring devices (Crystaleye Spectrophotometer(®), CAS-ID1, MSC-2000) were tested and the differences in color measurements among them were evaluated using Scheffe's F-test. Color measurements with the Crystaleye Spectrophotometer(®) were repeated 10 times by the same operator. The color difference (ΔE) between the first and tenth measurements was calculated. The Crystaleye Spectrophotometer(®) was used to measure the color of the maxillary left central incisor under two conditions (light and dark) and the effect of exterior lighting was analyzed to assess the accuracy of measurements. Furthermore, five different operators performed color measurements, and ΔE among the three devices was calculated. The ΔE between the target tooth and the crown of a single maxillary central incisor crown fabricated using data from the Crystaleye Spectrophotmeter(®) was calculated. Color differences between prebleaching and postbleaching were also analyzed with the Crystaleye Spectrophotometer(®) using the parameters ΔE, ΔL*, Δa*, and Δb*. The data from the three spectrophotometers were not significantly different. The ΔE during repeated color measurements by the same operator was 0.6. The ΔE between light and dark conditions was 0.9. The data from the five operators were not significantly different. The mean ΔE value between the target tooth and the fabricated crown was 1.2 ± 0.4, and the mean ΔE value between prebleaching and postbleaching was 3.7 ± 1.0. The Crystaleye Spectrophotometer(®) is an easy-to-use color analysis system producing accurate color measurements under clinical conditions. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Measurement of protein-like fluorescence in river and waste water using a handheld spectrophotometer.

    Science.gov (United States)

    Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm

    2004-07-01

    Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.

  5. Absolute flux scale for radioastronomy

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Stankevich, K.S.

    1986-01-01

    The authors propose and provide support for a new absolute flux scale for radio astronomy, which is not encumbered with the inadequacies of the previous scales. In constructing it the method of relative spectra was used (a powerful tool for choosing reference spectra). A review is given of previous flux scales. The authors compare the AIS scale with the scale they propose. Both scales are based on absolute measurements by the ''artificial moon'' method, and they are practically coincident in the range from 0.96 to 6 GHz. At frequencies above 6 GHz, 0.96 GHz, the AIS scale is overestimated because of incorrect extrapolation of the spectra of the primary and secondary standards. The major results which have emerged from this review of absolute scales in radio astronomy are summarized

  6. Objective evaluation of whiteness of cooked rice and rice cakes using a portable spectrophotometer.

    Science.gov (United States)

    Goto, Hajime; Asanome, Noriyuki; Suzuki, Keitaro; Sano, Tomoyoshi; Saito, Hiroshi; Abe, Yohei; Chuba, Masaru; Nishio, Takeshi

    2014-03-01

    The whiteness of cooked rice and rice cakes was evaluated using a portable spectrophotometer with a whiteness index (WI). Also, by using boiled rice for measurement of Mido values by Mido Meter, it was possible to infer the whiteness of cooked rice without rice cooking. In the analysis of varietal differences of cooked rice, 'Tsuyahime', 'Koshihikari' and 'Koshinokaori' showed high whiteness, while 'Satonoyuki' had inferior whiteness. The whiteness of rice cakes made from 'Koyukimochi' and 'Dewanomochi' was higher than the whiteness of those made from 'Himenomochi' and 'Koganemochi'. While there was a significant correlation (r = 0.84) between WI values and whiteness scores of cooked rice by the sensory test, no correlation was detected between the whiteness scores and Mido values, indicating that the values obtained by a spectrophotometer differ from those obtained by a Mido Meter. Thus, a spectrophotometer may be a novel device for measurement of rice eating quality.

  7. An ultraviolet-visible spectrophotometer automation system. Part 3: Program documentation

    Science.gov (United States)

    Roth, G. S.; Teuschler, J. M.; Budde, W. L.

    1982-07-01

    The Ultraviolet-Visible Spectrophotometer (UVVIS) automation system accomplishes 'on-line' spectrophotometric quality assurance determinations, report generations, plot generations and data reduction for chlorophyll or color analysis. This system also has the capability to process manually entered data for the analysis of chlorophyll or color. For each program of the UVVIS system, this document contains a program description, flowchart, variable dictionary, code listing, and symbol cross-reference table. Also included are descriptions of file structures and of routines common to all automated analyses. The programs are written in Data General extended BASIC, Revision 4.3, under the RDOS operating systems, Revision 6.2. The BASIC code has been enhanced for real-time data acquisition, which is accomplished by CALLS to assembly language subroutines. Two other related publications are 'An Ultraviolet-Visible Spectrophotometer Automation System - Part I Functional Specifications,' and 'An Ultraviolet-Visible Spectrophotometer Automation System - Part II User's Guide.'

  8. Relativistic Absolutism in Moral Education.

    Science.gov (United States)

    Vogt, W. Paul

    1982-01-01

    Discusses Emile Durkheim's "Moral Education: A Study in the Theory and Application of the Sociology of Education," which holds that morally healthy societies may vary in culture and organization but must possess absolute rules of moral behavior. Compares this moral theory with current theory and practice of American educators. (MJL)

  9. Forcing absoluteness and regularity properties

    NARCIS (Netherlands)

    Ikegami, D.

    2010-01-01

    For a large natural class of forcing notions, we prove general equivalence theorems between forcing absoluteness statements, regularity properties, and transcendence properties over L and the core model K. We use our results to answer open questions from set theory of the reals.

  10. Some absolutely effective product methods

    Directory of Open Access Journals (Sweden)

    H. P. Dikshit

    1992-01-01

    Full Text Available It is proved that the product method A(C,1, where (C,1 is the Cesàro arithmetic mean matrix, is totally effective under certain conditions concerning the matrix A. This general result is applied to study absolute Nörlund summability of Fourier series and other related series.

  11. Vacuum-ultraviolet circular dichroism of amino acids as revealed by synchrotron radiation spectrophotometer

    International Nuclear Information System (INIS)

    Matsuo, Koichi; Matsushima, Yosuke; Fukuyama, Takayuki; Gekko, Kunihiko; Senba, Shinya

    2002-01-01

    We succeeded in constructing a vacuum-ultraviolet circular dichroism (VUVCD) spectrophotometer with a small-scale synchrotron radiation source (0.7 GeV) at Hiroshima Synchrotron Radiation Center (HiSOR). This VUVCD system revealed for the first time the CD spectra of amino acids in aqueous media in the 310-140 nm region under high vacuum. These data, which cannot be observed by any types of existing CD spectrophotometers, now open a new field in the structural analysis of biomaterials on a basis of the higher energy transition of chromophores. (author)

  12. Shade determination using camouflaged visual shade guides and an electronic spectrophotometer.

    Science.gov (United States)

    Kvalheim, S F; Øilo, M

    2014-03-01

    The aim of the present study was to compare a camouflaged visual shade guide to a spectrophotometer designed for restorative dentistry. Two operators performed analyses of 66 subjects. One central upper incisor was measured four times by each operator; twice with a camouflaged visual shade guide and twice with a spectrophotometer Both methods had acceptable repeatability rates, but the electronic shade determination showed higher repeatability. In general, the electronically determined shades were darker than the visually determined shades. The use of a camouflaged visual shade guide seems to be an adequate method to reduce operator bias.

  13. Moral absolutism and ectopic pregnancy.

    Science.gov (United States)

    Kaczor, C

    2001-02-01

    If one accepts a version of absolutism that excludes the intentional killing of any innocent human person from conception to natural death, ectopic pregnancy poses vexing difficulties. Given that the embryonic life almost certainly will die anyway, how can one retain one's moral principle and yet adequately respond to a situation that gravely threatens the life of the mother and her future fertility? The four options of treatment most often discussed in the literature are non-intervention, salpingectomy (removal of tube with embryo), salpingostomy (removal of embryo alone), and use of methotrexate (MXT). In this essay, I review these four options and introduce a fifth (the milking technique). In order to assess these options in terms of the absolutism mentioned, it will also be necessary to discuss various accounts of the intention/foresight distinction. I conclude that salpingectomy, salpingostomy, and the milking technique are compatible with absolutist presuppositions, but not the use of methotrexate.

  14. Absolute magnitudes by statistical parallaxes

    International Nuclear Information System (INIS)

    Heck, A.

    1978-01-01

    The author describes an algorithm for stellar luminosity calibrations (based on the principle of maximum likelihood) which allows the calibration of relations of the type: Msub(i)=sup(N)sub(j=1)Σqsub(j)Csub(ij), i=1,...,n, where n is the size of the sample at hand, Msub(i) are the individual absolute magnitudes, Csub(ij) are observational quantities (j=1,...,N), and qsub(j) are the coefficients to be determined. If one puts N=1 and Csub(iN)=1, one has q 1 =M(mean), the mean absolute magnitude of the sample. As additional output, the algorithm provides one also with the dispersion in magnitude of the sample sigmasub(M), the mean solar motion (U,V,W) and the corresponding velocity ellipsoid (sigmasub(u), sigmasub(v), sigmasub(w). The use of this algorithm is illustrated. (Auth.)

  15. PMAS: The Potsdam Multi-Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak

    NARCIS (Netherlands)

    Kelz, Andreas; Verheijen, Marc A. W.; Roth, Martin M.; Bauer, Svend M.; Becker, Thomas; Paschke, Jens; Popow, Emil; Sánchez, Sebastian F.; Laux, Uwe

    2006-01-01

    PPak is a new fiber-based integral field unit (IFU) developed at the Astrophysical Institute of Potsdam and implemented as a module into the existing Potsdam Multi-Aperture Spectrophotometer (PMAS) spectrograph. The purpose of PPak is to provide an extended field of view with a large

  16. Spectrophotometer and ultrasound evaluation of late toxicity following breast-cancer radiotherapy.

    Science.gov (United States)

    Yoshida, E J; Chen, H; Torres, M A; Curran, W J; Liu, T

    2011-10-01

    Radiation-induced normal-tissue toxicities are common, complex, and distressing side effects that affect 90% of patients receiving breast-cancer radiotherapy and 40% of patients post radiotherapy. In this study, the authors investigated the use of spectrophotometry and ultrasound to quantitatively measure radiation-induced skin discoloration and subcutaneous-tissue fibrosis. The study's purpose is to determine whether skin discoloration correlates with the development of fibrosis in breast-cancer radiotherapy. Eighteen breast-cancer patients were enrolled in our initial study. All patients were previously treated with a standard course of radiation, and the median follow-up time was 22 months. The treated and untreated breasts were scanned with a spectrophotometer and an ultrasound. Two spectrophotometer parameters-melanin and erythema indices-were used to quantitatively assess skin discoloration. Two ultrasound parameters-skin thickness and Pearson coefficient of the hypodermis-were used to quantitatively assess severity of fibrosis. These measurements were correlated with clinical assessments (RTOG late morbidity scores). Significant measurement differences between the treated and contralateral breasts were observed among all patients: 27.3% mean increase in skin thickness (p spectrophotometer parameters do not correlate with ultrasound parameters. Spectrophotometry and quantitative ultrasound are objective tools that assess radiation-induced tissue injury. Spectrophotometer parameters did not correlate with those of quantitative ultrasound suggesting that skin discoloration cannot be used as a marker for subcutaneous fibrosis. These tools may prove useful for the reduction of radiation morbidities and improvement of patient quality of life.

  17. [An optical-fiber-sensor-based spectrophotometer for soil non-metallic nutrient determination].

    Science.gov (United States)

    He, Dong-xian; Hu, Juan-xiu; Lu, Shao-kun; He, Hou-yong

    2012-01-01

    In order to achieve rapid, convenient and efficient soil nutrient determination in soil testing and fertilizer recommendation, a portable optical-fiber-sensor-based spectrophotometer including immersed fiber sensor, flat field holographic concave grating, and diode array detector was developed for soil non-metallic nutrient determination. According to national standard of ultraviolet and visible spectrophotometer with JJG 178-2007, the wavelength accuracy and repeatability, baseline stability, transmittance accuracy and repeatability measured by the prototype instrument were satisfied with the national standard of III level; minimum spectral bandwidth, noise and excursion, and stray light were satisfied with the national standard of IV level. Significant linear relationships with slope of closing to 1 were found between the soil available nutrient contents including soil nitrate nitrogen, ammonia nitrogen, available phosphorus, available sulfur, available boron, and organic matter measured by the prototype instrument compared with that measured by two commercial single-beam-based and dual-beam-based spectrophotometers. No significant differences were revealed from the above comparison data. Therefore, the optical-fiber-sensor-based spectrophotometer can be used for rapid soil non-metallic nutrient determination with a high accuracy.

  18. An Improved Flame Test for Qualitative Analysis Using a Multichannel UV-Visible Spectrophotometer

    Science.gov (United States)

    Blitz, Jonathan P.; Sheeran, Daniel J.; Becker, Thomas L.

    2006-01-01

    Qualitative analysis schemes are used in undergraduate laboratory settings as a way to introduce equilibrium concepts and logical thinking. The main component of all qualitative analysis schemes is a flame test, as the color of light emitted from certain elements is distinctive and a flame photometer or spectrophotometer in each laboratory is…

  19. Authentic Performance in the Instrumental Analysis Laboratory: Building a Visible Spectrophotometer Prototype

    Science.gov (United States)

    Wilson, Mark V.; Wilson, Erin

    2017-01-01

    In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…

  20. Absolute gravity measurements in California

    Science.gov (United States)

    Zumberge, M. A.; Sasagawa, G.; Kappus, M.

    1986-08-01

    An absolute gravity meter that determines the local gravitational acceleration by timing a freely falling mass with a laser interferometer has been constructed. The instrument has made measurements at 11 sites in California, four in Nevada, and one in France. The uncertainty in the results is typically 10 microgal. Repeated measurements have been made at several of the sites; only one shows a substantial change in gravity.

  1. The Absolute Immanence in Deleuze

    OpenAIRE

    Park, Daeseung

    2013-01-01

    The absolute immanence in Deleuze Daeseung Park Abstract The plane of immanence is not unique. Deleuze and Guattari suppose a multiplicity of planes. Each great philosopher draws new planes on his own way, and these planes constitute the "time of philosophy". We can, therefore, "present the entire history of philosophy from the viewpoint of the institution of a plane of immanence" or present the time of philosophy from the viewpoint of the superposition and of the coexistence of planes. Howev...

  2. Utilization of Android-base Smartphone to Support Handmade Spectrophotometer : A Preliminary Study

    Science.gov (United States)

    Ujiningtyas, R.; Apriliani, E.; Yohana, I.; Afrillianti, L.; Hikmah, N.; Kurniawan, C.

    2018-04-01

    Visible spectrophotometer is a powerful instrument in chemistry. We can identify the chemical species base on their specific color and then we can also determine the amount of the species using the spectrophotometer. However, the availability of visible spectrophotometer still limited, particularly for education. This affect the skill of student to have experience on handling the instrumentation. On the other hand, the communication technology creates an opportunity for student to explore their smart feature, mainly the camera. The objective of this research is to make an application that utilize the camera feature as a detector for handmade visible spectrophotometer. The software have been made based on android program, and we name it as Spectrophone®. The spectrophotometer consists of an acrylic body, sample compartment, and light sources (USB-LED lamp powered by 6600 mAh battery). Before reach the sample, the light source was filtered using colored-mica plastic. The spectrophone® apps utilize the camera to detect the color based on its RGB composition. A different colored solution will show a different RGB composition based on the concentration and specific absorbance wavelength. We then can choose one type of color composition, R or G or B only to be converted as an absorbance using -Log (Cs/Co), where Cs and Co are color composition of sample and blank, respectively. The calibration curve of metilen blue measured. In a red (R) composition, the regression is not linear (R2=0.78) compare to the result of UV-Vis spectrophotomer model Spectroquant Pharo 300 (R2=0.8053). This measurement result shows that The Spectrophone® still need to be evaluated and corrected. One problem than can we identify that the diameter of pick point of RGB composition is too wide and this will affect the reading color composition. Next, we will fix the problem and in advance we will apply this Spectrophone® in a wide scale.

  3. COBE's search for structure in the Big Bang

    Science.gov (United States)

    Soffen, Gerald (Editor); Guerny, Gene (Editor); Keating, Thomas (Editor); Moe, Karen (Editor); Sullivan, Walter (Editor); Truszkowski, Walt (Editor)

    1989-01-01

    The launch of Cosmic Background Explorer (COBE) and the definition of Earth Observing System (EOS) are two of the major events at NASA-Goddard. The three experiments contained in COBE (Differential Microwave Radiometer (DMR), Far Infrared Absolute Spectrophotometer (FIRAS), and Diffuse Infrared Background Experiment (DIRBE)) are very important in measuring the big bang. DMR measures the isotropy of the cosmic background (direction of the radiation). FIRAS looks at the spectrum over the whole sky, searching for deviations, and DIRBE operates in the infrared part of the spectrum gathering evidence of the earliest galaxy formation. By special techniques, the radiation coming from the solar system will be distinguished from that of extragalactic origin. Unique graphics will be used to represent the temperature of the emitting material. A cosmic event will be modeled of such importance that it will affect cosmological theory for generations to come. EOS will monitor changes in the Earth's geophysics during a whole solar color cycle.

  4. Android Apps for Absolute Beginners

    CERN Document Server

    Jackson, Wallace

    2011-01-01

    Anybody can start building simple apps for the Android platform, and this book will show you how! Android Apps for Absolute Beginners takes you through the process of getting your first Android applications up and running using plain English and practical examples. It cuts through the fog of jargon and mystery that surrounds Android application development, and gives you simple, step-by-step instructions to get you started.* Teaches Android application development in language anyone can understand, giving you the best possible start in Android development * Provides simple, step-by-step exampl

  5. Absolute pitch: a case study.

    Science.gov (United States)

    Vernon, P E

    1977-11-01

    The auditory skill known as 'absolute pitch' is discussed, and it is shown that this differs greatly in accuracy of identification or reproduction of musical tones from ordinary discrimination of 'tonal height' which is to some extent trainable. The present writer possessed absolute pitch for almost any tone or chord over the normal musical range, from about the age of 17 to 52. He then started to hear all music one semitone too high, and now at the age of 71 it is heard a full tone above the true pitch. Tests were carried out under controlled conditions, in which 68 to 95 per cent of notes were identified as one semitone or one tone higher than they should be. Changes with ageing seem more likely to occur in the elasticity of the basilar membrane mechanisms than in the long-term memory which is used for aural analysis of complex sounds. Thus this experience supports the view that some resolution of complex sounds takes place at the peripheral sense organ, and this provides information which can be incorrect, for interpretation by the cortical centres.

  6. Absolute measurement of 152Eu

    International Nuclear Information System (INIS)

    Baba, Hiroshi; Baba, Sumiko; Ichikawa, Shinichi; Sekine, Toshiaki; Ishikawa, Isamu

    1981-08-01

    A new method of the absolute measurement for 152 Eu was established based on the 4πβ-γ spectroscopic anti-coincidence method. It is a coincidence counting method consisting of a 4πβ-counter and a Ge(Li) γ-ray detector, in which the effective counting efficiencies of the 4πβ-counter for β-rays, conversion electrons, and Auger electrons were obtained by taking the intensity ratios for certain γ-rays between the single spectrum and the spectrum coincident with the pulses from the 4πβ-counter. First, in order to verify the method, three different methods of the absolute measurement were performed with a prepared 60 Co source to find excellent agreement among the results deduced by them. Next, the 4πβ-γ spectroscopic coincidence measurement was applied to 152 Eu sources prepared by irradiating an enriched 151 Eu target in a reactor. The result was compared with that obtained by the γ-ray spectrometry using a 152 Eu standard source supplied by LMRI. They agreed with each other within the error of 2%. (author)

  7. Development of a Novel Spectrophotometer for Biochemical Analyzer Based on Volume Holography Transmissive Grating and Linear CCD

    International Nuclear Information System (INIS)

    Ren Zhong; Liu Guodong; Huang Zhen; Zeng Lvming; Dai Longmin

    2011-01-01

    The classical surface-embossed plane and concave grating are usually used as the diffraction grating in some spectrophotometers. But the minute cracks are produced on the surface of the gratings' grooves, which leads to generate the stray-light and decrease the efficiency of instrument. Therefore, a novel custom-built spectrophotometer for BCA is developed in this paper. Meanwhile, the volume holography transmissive (VHT) grating is used as the diffraction grating in this spectrophotometer. Additionally, a high resolution CCD and data acquisition (DAQ) card with combined the virtual software platform based on LabVIEW are used to design the spectral acquisition and analysis system. Experimental results show that the spectral range and the diffraction efficiency of the spectrophotometer for BCA are greatly increased. The spectral range of the spectrophotometer for BCA can reach 300-1000 nm, its wavelength resolution can reach 1nm. And, it uses the back-splitting-light technology and multi-channel parallel analysis. Compared with other same types, this spectrophotometer has many advantages, such as, higher efficiency, simpler algorithm, higher accuracy, cheaper cost and fewer stray-light and higher imaging quality, etc. Therefore, this spectrophotometer for BCA based on VHT grating will has the greatly potential values in the fields of the biochemical or medical research.

  8. Interference of different ionic species on the analysis of phosphate in HLW using spectrophotometer

    International Nuclear Information System (INIS)

    Mishra, P.K.; Ghongane, D.E.; Valsala, T.P.; Sonavane, M.S.; Kulkarni, Y.; Changrani, R.D.

    2010-01-01

    During reprocessing of spent nuclear fuel by PUREX process different categories of radioactive liquid wastes like High Level (HL), Intermediate Level (IL) and Low Level (LL) are generated. Different methodologies are adopted for management of these wastes. Since PUREX solvent (30% Tri butyl phosphate-70% Normal Paraffin Hydrocarbon) undergoes chemical degradation in the highly acidic medium of dissolver solution, presence of phosphate in the waste streams is inevitable. Since higher concentrations of phosphate in the HLW streams will affect its management by vitrification, knowledge about the concentration of phosphate in the waste is essential before finalising the glass composition. Since a large number of anionic and cationic species are present in the waste, these species may interfere phosphate analysis using spectrophotometer. In the present work, the interference of different anionic and cationic species on the analysis of phosphate in waste solutions using spectrophotometer was studied

  9. Use of the SF-8 detection spectrophotometer for measuring absorption spectra of molten salts

    International Nuclear Information System (INIS)

    Kotlin, V.P.; Barbanel', Yu.A.

    1975-01-01

    Three versions of the use of the SF-8 spectrophotometer for high-temperature measurements are described: 1) based on the standard optical scheme at temperatures of up to 400 0 C; 2) based on a modified one-wave scheme; 3) based on a modified twin-wave scheme. The external heater used in the schemes 2 and 3 ensures that measurements can be performed at temperatures of up to 1000 0 C. In order to obtain the spectra of thin-layer samples vessels with an insert are used. For operation of the spectrophotometer according to the schemes 2 and 3 te heater may in principle be replaced by a cryostat or some other external device

  10. Application of ZnO Nanoparticle as Sulphide Gas Sensor Using UV/VIS/NIR-Spectrophotometer

    International Nuclear Information System (INIS)

    Juliasih, N; Buchari; Noviandri, I

    2017-01-01

    The nanoparticle of metal oxides has great unique characteristics that applicable to the wide industrial as sensors and catalysts for reducing environmental pollution. Sulphide gas monitors and detectors are required for assessing safety aspects, due to its toxicity level. A thin film of ZnO as the sulphide gas sensor was synthesised by the simple method of chemical liquid deposition with variation of annealing temperature from 200 ºC to 500 ºC, and characterised by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), and UV/VIS/NIR-Spectrophotometer. Characterization studies showed nanoparticle size from the range 62 – 92 nm of diameters. The application this ZnO thin film to sulfide gas, detected by UV/VIS/NIR Spectrophotometer with diffuse reflectance, showed specific chemical reaction by the shifting of maximum % Reflectance peak. The gas sensing using this method is applicable at room. (paper)

  11. Construction, calibration, and application of a compact spectrophotometer for EUV(300-2500 A) plasma diagnostics

    International Nuclear Information System (INIS)

    Moos, H.W.; Chen, K.I.; Terry, J.L.

    1979-01-01

    A 400-mm normal incidence concave grating spectrophotometer, specifically designed for plasma diagnostics, is described. The wavelength drive, in which the grating is translated as well as rotated, is discussed in detail; the wavelength linearity of the sine drive and methods of improving it are analyzed. The instrument can be used in any orientation, is portable under vacuum, and quite rugged. The construction techniques utilized produce a high quality vacuum making the instrument compatible with both high purity plasma devices and synchrotron radiation sources. The photometric sensitivity calibration was found to be very stable during extended use on high temperature plasma devices. The applications of the instrument to diagnose plasmas in two tokamaks and a mirror device are decribed. A facility used for photometric calibration of extreme ultraviolet (lambda>300-A) spectrophotometers against NBS standard diodes is described. The instrumental calibration obtained using this facility was checked by using synchrotron radiation from SURF II; very good agreement was observed

  12. Differences between the human eye and the spectrophotometer in the shade matching of tooth colour.

    Science.gov (United States)

    Gómez-Polo, Cristina; Gómez-Polo, Miguel; Celemin-Viñuela, Alicia; Martínez Vázquez De Parga, Juan Antonio

    2014-06-01

    The aim of this work was to assess the agreement between instrumental and visual colour matching. Shade selection with the 3DMaster Toothguide (Vita-Zahnfabrik) was performed for 1361 maxillary central incisors and compared with the shade obtained with the EasyShade Compact (Vita-Zahnfabrik) spectrophotometer. We observed a greater correlation between the objective method and the subjective one in the colour dimension of lightness (Kappa 0.6587), followed by hue (Kappa 0.4337) and finally chroma (Kappa 0.3578). The colour dimension in which the greatest agreement is seen between the operator and the spectrophotometer is value or lightness. This study reveals differences between the measurement of colour via spectrophotometry and the visual shade selection method. According to our results, there is better agreement in the value or lightness colour dimension, which is the most important one in the choice of tooth colour. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Flameless atomic absorption determination of ruthenium using a ''Saturn-1'' spectrophotometer

    International Nuclear Information System (INIS)

    Pichkov, V.N.; Sinitsyn, N.M.; Sadikova, F.G.; Govorova, M.I.; Yakshinskij, A.I.

    1980-01-01

    A flameless atomic absorption method is suggested for determining ruthenium in samples of complicated composition using a ''Saturn-1'' spectrophotometer with a L'vov graphite cuvette. The method was used for determining ruthenium in a copper-based sample (10 -3 % Ru) and in electrolyte slurries (10 -3 -10 -2 %). The limit of detection Csub(min, 0.95) = 3.0x10 -3 μg Ru/ml. Other platinum metals do not interfere [ru

  14. Development of optical spectrum acquisition with spectrophotometer for characterization of optical radiation sources

    International Nuclear Information System (INIS)

    Solano Vargas, Alvaro

    2013-01-01

    An improved process of the data acquisition system is developed with Pasco 750 interface and Pasco OS-8539 spectrophotometer. The optical spectrum and color temperature of incandescent sources available are obtained from the Laboratorio de Fotonica y Tecnologia Laser Aplicada. The procedures developed in the project are recommended to collect data and analyze results. The purchase of a new Software and the interface of Pasco is recommended to have a better operation and update [es

  15. Absolute measurement of 85Sr

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Watanabe, Tamaki

    1978-01-01

    An extension of 4πe.x-γ coincidence technique is described to measure the absolute disintegration rate of 85 Sr. This nuclide shows electron capture-gamma decay, and 514keV level of 85 Rb is a meta-stable state with half life of 0.958 μsec. Therefore, the conventional 4 πe.x-γ coincidence technique with about 1 μsec of resolution time can not be applied to this nuclide. To measure the absolute disintegration rate of this, the delayed 4 πe.x-γ coincidence technique with two different resolution time has been used. The disintegration rate was determined from four counting rates of electron-x ray, gamma ray and two coincidences, and the true disintegration rate could be obtained by extraporation of the electron-x ray detection efficiency to 1. Two resolution time appearing in the calculation formulas were determined from the chance coincidence between electron-x ray and delayed gamma ray signals. When the coincidence countings with three different resolution time were carried out by one coincidence circuit, the results calculated from all combinations did not agree each other. However, when the two coincidence circuits of the same type were used to fix the resolution time, a good coincidence absorption function was obtained and the disintegration rate was determined with accuracy of +- 0.5%. To evaluate the validity of the results the disintegration rates were measured by two NaI (Tl) scintillation detectors whose gamma-ray detection efficiency was previously determined and both results were agreed within accuracy of +- 0.5%. This method can be applied with nearly same accuracy for the beta-gamma decay nuclide possessing a meta-stable state of the half life below about 10 μsec. (auth.)

  16. Development of Simple and Precise Method of Arginine Determination in Rumen Fluid by Spectrophotometer

    International Nuclear Information System (INIS)

    Chacher, B.; Marghazani, I. B.; Liu, J. X.; Liu, H. Y.

    2015-01-01

    The objective of current study was to build up a convenient, economic and accurate procedure to determine arginine (ARG) concentration in rumen fluid. Rumen fluid was collected from 3 rumen fistulated Chinese Holstein dairy cows and added with or without (control) 1mmol/l unprotected ARG and blank (with only medium) in to syringe system in triplicate as a replicate. All syringes were incubated in water bath at 39 Degree C for 0, 2, 4, 6, 12 and 24 h and were terminated to measure the ARG concentration. Sakaguchi reaction method was used to analyze the ARG concentration in rumen fluid by determining the rumen degradation rate of protected and unprotected ARG. Temperature, time and absorbance were optimized in the procedure based on Sakaguchi reaction. Color consistency remained 4-6 min. The optimum temperature (0-5) Degree C was observed for maximum optical density 0.663 at wave length 500 nm. Minimum ARG that could be determined in rumen fluid by spectrophotometer was 4-5 μ g/ml. No significance (P>0.05) difference were observed between two results derived from spectrophotometer and amino acid analyzer methods. In conclusion, the spectrophotometer method of ARG determination in rumen fluid based on Sakaguchi reaction is easy, accurate, and economical and could be useful in learning ARG metabolism in the rumen. (author)

  17. Palmtop spectrophotometer for DNA and protein measurement in micro-nanoliter assays

    International Nuclear Information System (INIS)

    Qiu Tian; Huang Guoliang; Yang Xiaoyong; Ma Li; Yang Xu

    2011-01-01

    Spectrophotometer, an important tool in life science, medicine, and analytical fields, usually uses an optical path of 10 mm or more for absorbance measurement of UV light. This corresponds to a sample consumption of ≥ 50 μL in volume and a narrow measuring range of 0.5-50 ng/μL for nucleic acid samples and 0.05-2 mg/mL for protein samples. Higher concentrations must be diluted for measurement. In this paper, we developed an advanced palmtop spectrophotometer for the measurement of both DNA and protein concentrations in micro-nanoliter assays. We constructed a fiber transmission and a fiber reflection absorbance detection scheme illuminated by either UV-LED or deuterium lamp. The sensitivity of 0.5 ng/μL and a wide measuring range of 0.5-2000 ng/μL in concentrations were obtained for DNA, and the sensitivity of 0.05 mg/mL and a wide measuring range of 0.05-100 mg/mL were also obtained for protein. However, sample consumption is only 1 μL in volume for fiber transmission detection scheme and 500 nL for fiber reflection detection scheme. The linear correlation coefficient of measured concentrations to theoretical concentrations is greater than 0.99. With the profit of this work, a miniaturized spectrophotometer with better sensitivity and wider measuring range can be produced for analytical applications.

  18. Application of microplate spectrophotometer in determination of apparent amylose content and mutant selection in rice

    International Nuclear Information System (INIS)

    Zhu Xiaoyang; Shen Shengquan; Chen Wenyue; Shu Qingyao

    2004-01-01

    The application of automatic microplate spectrophotometer (SpectraMax 190, Sunnyvale, USA) was investigated for measurement of apparent amylose content (AAC) of rice grains. By using five rice varieties (IR24, Iri371, Z413, KMD1 and Xiushui 11), a microplate spectrophotometer-facilitated AAC measurement system was established with similar accuracy to that of standard protocol (NY147-88). In this system, sample was treated as NY147-88, but directly stained in a microplate and the OD values of each sample were determined by a microplate spectrophotometer. A regression equation was established by using the AAC and OD value of standard samples, and the AAC of test samples were estimated by using the equation. The system is simple, accurate and high-throughput. By using this system, about 1500 progenies of M 3 seeds (harvested from individual M 2 plants) were screened for putative AAC mutants, from which one mutant line ZXY16 was developed with a middle AAC of about 16%

  19. Quantitative analysis of skin reaction by reflectance spectrophotometer. Acute reaction following proton therapy

    International Nuclear Information System (INIS)

    Kawashima, Mitsuhiko; Okumura, Toshiyuki; Tatsuzaki, Hideo; Tsuji, Hiroshi; Tsujii, Hirohiko.

    1994-01-01

    Acute reactions induced by proton irradiation were measured using a reflectance spectrophotometer, which is commonly used in the printing and textile industries. In this method, the skin color was expressed by three parameters, lightness (L * ), chroma (C * ) and hue (h). At first, in order to evaluate the accuracy of this spectrophotometer, the skin color of a normal volunteer was measured 100 times. The values of the three parameters for normal skin were as follows (mean values and standard deviation), L * : 68.64±0.29, C * : 19.08±0.13, h: 69.41±0.76. The standard deviations with regard to L * and h, were considered to be sufficiently small when compared with the changes of these parameters (prefix: Δ) in the irradiated sites (ΔL * * and h values significantly decreased with time, and the L * values were highly correlated with elapsed treatment days. The h values had a relatively low linear correlation compared with L * . The C * values had no trends as the treatment period was extended. Among these parameters, the L * values were the most valuable for assessment of proton-induced skin reactions, and it was suggested that the L * values measured with this spectrophotometer were a useful index for showing biological effects induced by proton irradiation. Further experiments are needed to apply this method to quantify the biological effects induced by other forms of ionizing radiation. (author)

  20. Correlation between skin color evaluation by skin color scale chart and narrowband reflectance spectrophotometer.

    Science.gov (United States)

    Treesirichod, Arucha; Chansakulporn, Somboon; Wattanapan, Pattra

    2014-07-01

    Various methods are available for the evaluation of skin color. A skin color scale chart is a convenient and inexpensive tool. However, the correlation between a skin color scale chart and objective measurement has not been evaluated. To assess the correlation between skin color evaluation done by a skin color scale chart (Felix von Luschan skin color chart) and a narrowband reflectance spectrophotometer (Mexameter MX18). The participants were evaluated for skin color by using the Felix von Luschan skin color chart (range 1-36) and a narrowband reflectance spectrophotometer (Mexameter MX18) in which the results of the measurements were expressed as Erythema (E) and Melanin (M) indices. Skin color was measured on four different anatomical skin sites from each participant on the medial aspect of the volar and the dorsal regions of both forearms. A total of 208 records from 52 participants were established. The majority of participants (19.2%) were rated with the skin color scale at the number 16 (range 14-33). The mean M plus E, M, and E indices were 498.9 ± 143.9, 230.4 ± 74.4, and 268.5 ± 73.2, respectively. The correlation coefficient between the number on the skin color scale and each index: M plus E, M, and E indices were 0.90, 0.90, and 0.86, respectively, with a statistical significance of P spectrophotometer.

  1. Chemical Fouling Reduction of a Submersible Steel Spectrophotometer in Estuarine Environments Using a Sacrificial Zinc Anode.

    Science.gov (United States)

    Tait, Zachary S; Thompson, Megan; Stubbins, Aron

    2015-07-01

    The availability of in situ spectrophotometers, such as the S::CAN spectro::lyser, has expanded the possibilities for high-frequency water quality data collection. However, biological and chemical fouling can degrade the performance of in situ spectrophotometers, especially in saline environments with rapid flow rates. A complex freshwater washing system has been previously designed to reduce chemical fouling for the S::CAN spectro::lyser spectrophotometer. In the current study, we present a simpler, cheaper alternative: the attachment of a sacrificial zinc anode. Results are presented detailing the S::CAN spectro::lyser performance with and without the addition of the sacrificial anode. Attachment of the zinc anode provided efficient corrosion protection during 2-wk deployments in a highly dynamic (average tidal range, 2.5 m) saline tidal saltmarsh creek at Groves Creek, Skidaway Institute of Oceanography, Savannah, GA. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Development of an ultra-compact mid-infrared attenuated total reflectance spectrophotometer

    Science.gov (United States)

    Kim, Dong Soo; Lee, Tae-Ro; Yoon, Gilwon

    2014-07-01

    Mid-infrared spectroscopy has been an important tool widely used for qualitative analysis in various fields. However, portable or personal use is size and cost prohibitive for either Fourier transform infrared or attenuated total reflectance (ATR) spectrophotometers. In this study, we developed an ultra-compact ATR spectrophotometer whose frequency band was 5.5-11.0 μm. We used miniature components, such as a light source fabricated by semiconductor technology, a linear variable filter, and a pyro-electric array detector. There were no moving parts. Optimal design based on two light sources, a zippered configuration of the array detector and ATR optics could produce absorption spectra that might be used for qualitative analysis. A microprocessor synchronized the pulsed light sources and detector, and all the signals were processed digitally. The size was 13.5×8.5×3.5 cm3 and the weight was 300 grams. Due to its low cost, our spectrophotometer can replace many online monitoring devices. Another application could be for a u-healthcare system installed in the bathroom or attached to a smartphone for monitoring substances in body fluids.

  3. Data acquisition system and performance based on Apple II for using in experimental physics - Applications to spectrophotometer

    International Nuclear Information System (INIS)

    Costa, L.F.; Castro, J.C.

    1987-01-01

    A microcomputer based system oriented to experimental physics is described. The system was developed to achieve versatility, low cost, reliability and easy utilization. An application to this system to a dispersive spectrophotometer is also included. (author) [pt

  4. Fiberoptic spectrophotometer

    Science.gov (United States)

    Tans, Petrus P.; Lashof, Daniel A.

    1986-01-01

    A device for determining the relative composition of a sample of a gas by comparison of the Raman-scattered light of the sample with that of a known gas comprising: a means for passing a single light source through the unknown and the known gases, choppers to alternate the Raman-scattered light into a common light detection and measuring system, optical fiber networks for spatially mixing the resulting Raman scattered light from each sample and directing the mixed light to selective detectors, and a compiler to record the light intensity of each wavelength of Raman-scattered light as a function of the sample from which it originated.

  5. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems.

    Science.gov (United States)

    Parameswaran, Vidhya; Anilkumar, S; Lylajam, S; Rajesh, C; Narayan, Vivek

    2016-01-01

    This in vitro study compared the shade matching abilities of an intraoral spectrophotometer and the conventional visual method using two shade guides. The results of previous investigations between color perceived by human observers and color assessed by instruments have been inconclusive. The objectives were to determine accuracies and interrater agreement of both methods and effectiveness of two shade guides with either method. In the visual method, 10 examiners with normal color vision matched target control shade tabs taken from the two shade guides (VITAPAN Classical™ and VITAPAN 3D Master™) with other full sets of the respective shade guides. Each tab was matched 3 times to determine repeatability of visual examiners. The spectrophotometric shade matching was performed by two independent examiners using an intraoral spectrophotometer (VITA Easyshade™) with five repetitions for each tab. Results revealed that visual method had greater accuracy than the spectrophotometer. The spectrophotometer; however, exhibited significantly better interrater agreement as compared to the visual method. While VITAPAN Classical shade guide was more accurate with the spectrophotometer, VITAPAN 3D Master shade guide proved better with visual method. This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

  6. Absolute entropy of ions in methanol

    International Nuclear Information System (INIS)

    Abakshin, V.A.; Kobenin, V.A.; Krestov, G.A.

    1978-01-01

    By measuring the initial thermoelectromotive forces of chains with bromo-silver electrodes in tetraalkylammonium bromide solutions the absolute entropy of bromide-ion in methanol is determined in the 298.15-318.15 K range. The anti Ssub(Brsup(-))sup(0) = 9.8 entropy units value is used for calculation of the absolute partial molar entropy of alkali metal ions and halogenide ions. It has been found that, absolute entropy of Cs + =12.0 entropy units, I - =14.0 entropy units. The obtained ion absolute entropies in methanol at 298.15 K within 1-2 entropy units is in an agreement with published data

  7. Near threshold absolute TDCS: First results

    International Nuclear Information System (INIS)

    Roesel, T.; Schlemmer, P.; Roeder, J.; Frost, L.; Jung, K.; Ehrhardt, H.

    1992-01-01

    A new method, and first results for an impact energy 2 eV above the threshold of ionisation of helium, are presented for the measurement of absolute triple differential cross sections (TDCS) in a crossed beam experiment. The method is based upon measurement of beam/target overlap densities using known absolute total ionisation cross sections and of detection efficiencies using known absolute double differential cross sections (DDCS). For the present work the necessary absolute DDCS for 1 eV electrons had also to be measured. Results are presented for several different coplanar kinematics and are compared with recent DWBA calculations. (orig.)

  8. Satisfaction of Dental Students, Faculty, and Patients with Tooth Shade-Matching Using a Spectrophotometer.

    Science.gov (United States)

    Ballard, Erin; Metz, Michael J; Harris, Bryan T; Metz, Cynthia J; Chou, Jang-Ching; Morton, Dean; Lin, Wei-Shao

    2017-05-01

    The aims of this study were to evaluate dental students' clinical shade-matching outcomes (from subjective use of shade guide) with an objective electronic shade-matching tool (spectrophotometer); to assess patients', students', and supervising faculty members' satisfaction with the clinical shade-matching outcomes; and to assess clinicians' support for use of the spectrophotometer to improve esthetic outcomes. A total of 103 volunteer groups, each consisting of patient, dental student, and supervising faculty member at the University of Louisville, were recruited to participate in the study in 2015. Using the spectrophotometer, clinical shade-matching outcome (ΔE clinical ) and laboratory shade-matching outcome (ΔE laboratory ) were calculated. Two five-point survey items were used to assess the groups' satisfaction with the clinical shade-matching outcome and support for an objective electronic shade-matching tool in the student clinic. The results showed that both ΔE clinical (6.5±2.4) and ΔE laboratory (4.3±2.0) were outside the clinical acceptability threshold ΔE values of 2.7, when visual shade-matching method (subjective usage of shade guide) was used to fabricate definitive restorations. Characteristics of the patients, dental students, supervising faculty members, and restorations had minimal to no effect on the ΔE clinical The patients, dental students, and supervising faculty members generally had positive opinions about the clinical shade-matching outcome, despite the increased ΔE clinical observed. Overall, clinical shade-matching outcomes in this school need further improvement, but the patients' positive opinions may indicate the need to revisit the acceptability threshold ΔE value of 2.7 in the academic setting.

  9. A furnace and temperature controller for optical absorption studies with a spectrophotometer

    International Nuclear Information System (INIS)

    Mariani Rogat, F.

    1975-01-01

    The design and main features of a furnace with a temperature controller and programmer are shown. This system allows to measure the optical absorption spectrum of a sample from room temperature to 400 deg C, in a double beam spectrophotometer Perkin Elmer 350. The sample temperature can be linearly increased at different heating rates between 4 and 38 deg C/min. The temperature ramp can be stopped at any desired point and the sample temperature shall be stabilized in less than one minute. This temperature shall be kept constant within 0.5 deg C for hours. The sample is heated in vacuum. (author)

  10. Flight of a UV spectrophotometer aboard Galileo 2, the NASA Convair 990 aircraft

    Science.gov (United States)

    Sellers, B.; Hunderwadel, J. L.; Hanser, F. A.

    1976-01-01

    An ultraviolet interference-filter spectrophotometer (UVS) fabricated for aircraft-borne use on the DOT Climatic Impact Assessment Program (CIAP) has been successfully tested in a series of flights on the NASA Convair 990, Galileo II. UV flux data and the calculated total ozone above the flight path are reported for several of the flights. Good agreement is obtained with the total ozone as deducted by integration of an ozone sonde vertical profile obtained at Wallops Island, Virginia near the time of a CV-990 underpass. Possible advantages of use of the UVS in the NASA Global Atmospheric Sampling Program are discussed.

  11. A broad band X-ray imaging spectrophotometer for astrophysical studies

    Science.gov (United States)

    Lum, Kenneth S. K.; Lee, Dong Hwan; Ku, William H.-M.

    1988-01-01

    A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

  12. Determining the Absorbance Spectra of Photochromic Materials From Measured Spectrophotometer Data

    Science.gov (United States)

    Downie, John D.

    1998-01-01

    If a two-state photochromic material is optically bleached, the absorbance spectrum data measured by a spectrophotometer is in general comprised of components from both the ground state and the upper state. Under general conditions, it may be difficult to extract the actual upper state spectrum from the spectrum of the bleached material. A simple algorithm is presented here for the recovery of the pure absorbance spectra of the upper state of a material such as bacteriorhodopsin, given single wavelength bleaching illumination, steady-state conditions, and accurate knowledge of phototransition rates and thermal decay rates.

  13. Visible light nitrogen dioxide spectrophotometer intercomparison: Mount Kobau, British Columbia, July 28 to August 10, 1991

    Science.gov (United States)

    Mcelroy, C. T.; Elokhov, A. S.; Elansky, N.; Frank, H.; Johnston, P.; Kerr, J. B.

    1994-01-01

    Under the auspices of the World Meteorological Organization, Environment Canada hosted an international comparison of visible light spectrophotometers at Mt. Kobau, British Columbia in August of 1991. Instruments from four countries were involved. The intercomparison results have indicated that some significant differences exist in the responses of the various instruments, and have provided a basis for the comparison of the historical data sets which currently exist as a result of the independent researches carried out in the past in the former Soviet Union, New Zealand, and Canada.

  14. Image plane detector spectrophotometer - Application to O2 atmospheric band nightglow

    Science.gov (United States)

    Luo, Mingzhao; Yee, Jeng-Hwa; Hays, Paul B.

    1988-01-01

    A new variety of low resolution spectrometer is described. This device, an image plane detector spectrophotometer, has high sensitivity and modest resolution sufficient to determine the rotational temperature and brightness of molecular band emissions. It uses an interference filter as a dispersive element and a multichannel image plane detector as the photon collecting device. The data analysis technqiue used to recover the temperature of the emitter and the emission brightness is presented. The atmospheric band of molecular oxygen is used to illustrate the use of the device.

  15. Information-measurement and control system of the five-channel stellar spectrophotometer

    International Nuclear Information System (INIS)

    Granitskij, L.V.; Bukach, A.B.; Kaplin, Yu.V.; Bondarenko, V.P.; Smirnov, A.I.

    1979-01-01

    The multichannel information-measurement control system of the five-channel stellar spectrophotometer working in photon counting regime is described. The detecting part is synthesized taking into account the principles of multifunctional use of elements of the system. In the part of the photometer scanning mechanism control a discrete drive with the step motor is used. The data are detected on the punched tape, which is convenient for putting them into computer, into a digit printing device with the decimal code or on a diagram tape of the automatic potentiometer

  16. A method for calibration of Soleil-Babinet compensator using a spectrophotometer

    Science.gov (United States)

    Wang, Jun; Chen, Lei; Li, Bo; Shi, Lili; Luo, Ting

    2010-06-01

    A method using a spectrophotometer for calibrating Soleil-Babinet compensator is proposed. It is based on the spectroscopic method which utilizes the relation between transmittance and wavelength to obtain retardation. By placing a multiple order half wave plate behind the Soleil-Babinet compensator, zero-order retardation can be measured, which is difficult to accomplish by spectroscopic method. In the experiment, the retardations of the compensator in the range 0- λ are measured. It is demonstrated that the precision of retardation is 0.45 nm at the position 0 and λ while the maximum error is less than 1 nm between the two positions.

  17. Introducing the Mean Absolute Deviation "Effect" Size

    Science.gov (United States)

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  18. Investigating Absolute Value: A Real World Application

    Science.gov (United States)

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  19. Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer.

    Science.gov (United States)

    Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten

    2017-01-01

    Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.

  20. Evaluation of Biocompatibility of Root Canal Sealers on L929 Fibroblasts with Multiscan EX Spectrophotometer.

    Science.gov (United States)

    Konjhodzic-Prcic, Alma; Jakupovic, Selma; Hasic-Brankovic, Lajla; Vukovic, Amra

    2015-06-01

    The purpose of the current study was to estimate the biocompatibility of endodontic sealers with different bases on L929 mouse fibroblasts permanent cell line using Multiscan EX Spectrophotometer. Endodontics sealers used in this study were GuttaFlow (Roeko) silicone based sealer, AH plus (De Tray-DENTSPLY) epoxy resin based, Apexit (Vivadent) calcium hydroxide based and Endorez (Ultradent) methacrylate based sealer. Sealer were tested trough time, freshly mixed 24 h, 48h and 7 days after setting. Biocompatibility was determinate on permanent cell lines L929 mouse fibroblasts trough cytotoxicity using MTT assay. Level of absorption was measured with multi scan EX spectrophotometer on length 420-600 nm. Sealer based on calcium hydroxide Apexit Plus, GuttaFlow silicone based sealer and AH plus epoxy resin based sealer, have shown a low cytotoxicity through the all periods of time on culture of L292 mouse fibroblasts. Methacrylate based sealer, Endorez showed moderate cytotoxicity when freshly mixed and after 7 days. After 24 hours the visibility of the cells was 74,0% and after 48 hours 65,1%. which is slightly cytotoxic. According to results of this study there is a statistically significant difference among the groups p<0,05 for all the tested sealers. Apexit Plus, GuttaFlow and AH plus can be considered as biocompatibile. EndoREZ sealer which is based on methacrylate, after 7 days shows 50,1% of visible live cells which is considered as moderate cytotoxicity.

  1. White light photothermal lens spectrophotometer for the determination of absorption in scattering samples.

    Science.gov (United States)

    Marcano, Aristides; Alvarado, Salvador; Meng, Junwei; Caballero, Daniel; Moares, Ernesto Marín; Edziah, Raymond

    2014-01-01

    We developed a pump-probe photothermal lens spectrophotometer that uses a broadband arc-lamp and a set of interference filters to provide tunable, nearly monochromatic radiation between 370 and 730 nm as the pump light source. This light is focused onto an absorbing sample, generating a photothermal lens of millimeter dimensions. A highly collimated monochromatic probe light from a low-power He-Ne laser interrogates the generated lens, yielding a photothermal signal proportional to the absorption of light. We measure the absorption spectra of scattering dye solutions using the device. We show that the spectra are not affected by the presence of scattering, confirming that the method only measures the absorption of light that results in generation of heat. By comparing the photothermal spectra with the usual absorption spectra determined using commercial transmission spectrophotometers, we estimate the quantum yield of scattering of the sample. We discuss applications of the device for spectroscopic characterization of samples such as blood and gold nanoparticles that exhibit a complex behavior upon interaction with light.

  2. Non-invasive prediction of hematocrit levels by portable visible and near-infrared spectrophotometer.

    Science.gov (United States)

    Sakudo, Akikazu; Kato, Yukiko Hakariya; Kuratsune, Hirohiko; Ikuta, Kazuyoshi

    2009-10-01

    After blood donation, in some individuals having polycythemia, dehydration causes anemia. Although the hematocrit (Ht) level is closely related to anemia, the current method of measuring Ht is performed after blood drawing. Furthermore, the monitoring of Ht levels contributes to a healthy life. Therefore, a non-invasive test for Ht is warranted for the safe donation of blood and good quality of life. A non-invasive procedure for the prediction of hematocrit levels was developed on the basis of a chemometric analysis of visible and near-infrared (Vis-NIR) spectra of the thumbs using portable spectrophotometer. Transmittance spectra in the 600- to 1100-nm region from thumbs of Japanese volunteers were subjected to a partial least squares regression (PLSR) analysis and leave-out cross-validation to develop chemometric models for predicting Ht levels. Ht levels of masked samples predicted by this model from Vis-NIR spectra provided a coefficient of determination in prediction of 0.6349 with a standard error of prediction of 3.704% and a detection limit in prediction of 17.14%, indicating that the model is applicable for normal and abnormal value in Ht level. These results suggest portable Vis-NIR spectrophotometer to have potential for the non-invasive measurement of Ht levels with a combination of PLSR analysis.

  3. Vertical-type chiroptical spectrophotometer (I): instrumentation and application to diffuse reflectance circular dichroism measurement.

    Science.gov (United States)

    Harada, Takunori; Hayakawa, Hiroshi; Kuroda, Reiko

    2008-07-01

    We have designed and built a novel universal chiroptical spectrophotometer (UCS-2: J-800KCMF), which can carry out in situ chirality measurement of solid samples without any pretreatment, in the UV-vis region and with high relative efficiency. The instrument was designed to carry out transmittance and diffuse reflectance (DR) circular dichroism (CD) measurements simultaneously, thus housing two photomultipliers. It has a unique feature that light impinges on samples vertically so that loose powders can be measured by placing them on a flat sample holder in an integrating sphere. As is our first universal chiroptical spectrophotometer, UCS-1, two lock-in amplifiers are installed to remove artifact signals arising from macroscopic anisotropies which are unique to solid samples. High performance was achieved by theoretically analyzing and experimentally proven the effect of the photoelastic modulator position on the CD base line shifts, and by selecting high-quality optical and electric components. Measurement of microcrystallines of both enantiomers of ammonium camphorsulfonate by the DRCD mode gave reasonable results.

  4. Laser-plasma sourced, temperature dependent, VUV spectrophotometer using dispersive analysis

    International Nuclear Information System (INIS)

    French, R.H.

    1990-01-01

    We have developed a vacuum ultraviolet spectrophotometer with wide energy and temperature range coverage, utilizing a laser-plasma light source (LPLS), CO 2 -laser sample heating and time-resolved dispersive analysis. Reflection and transmission spectra can be taken from 1.7 to 40 eV (31-700 nm) on samples at 15-1800 K with a time resolution of 20-400 ns. These capabilities permit the study of the temperature dependence of the electronic structure, encompassing the effects of thermal lattice expansion and electron-phonon interaction, and changes in the electronic structure associated with equilibrium and metastable phase transitions and stress relaxation. The LPLS utilizes a samarium laser-plasma created by a Q-switched Nd:YAG laser (500 mJ/pulse) to produce high brightness, stable, continuum radiation. The spectrophotometer is of a single beam design using calibrated iridium reference mirrors. White light is imaged off the sample in to the entrance slit of a 1-m polychromator. The resolution is 0.1 to 0.3 nm. The dispersed light is incident on a focal plane phosphor, fiber-optic-coupled to an image-intensified reticon detector. For spectroscopy between 300 and 1800 K, the samples are heated in situ with a 150 Watt CO 2 laser. The signal to noise ratio in the VUV, for samples at 1800 K, is excellent. From 300 K to 15 K samples are cooled using a He cryostat. (orig.)

  5. [Design of flat field holographic concave grating for near-infrared spectrophotometer].

    Science.gov (United States)

    Xiang, Xian-Yi; Wen, Zhi-Yu

    2008-07-01

    Near-infrared spectrum analysis can be used to determine the nature or test quantitatively some chemical compositions by detecting molecular double frequency and multiple frequency absorption. It has been used in agriculture, biology, petrifaction, foodstuff, medicament, spinning and other fields. Near-infrared spectrophotometer is the main apparatus for near-infrared spectrum analysis, and the grating is the most important part of the apparatus. Based on holographic concave grating theory and optic design software CODE V, a flat field holographic concave grating for near-infrared spectrophotometer was designed from primary structure, which relied on global optimization of the software. The contradiction between wide spectrum bound and limited spectrum extension was resolved, aberrations were reduced successfully, spectrum information was utilized fully, and the optic structure of spectrometer was highly efficient. Using CODE V software, complex high-order aberration equations need not be solved, the result can be evaluated quickly, flat field and resolving power can be kept in balance, and the work efficiency is also enhanced. A paradigm of flat field holographic concave grating is given, it works between 900 nm to 1 700 nm, the diameter of the concave grating is 25 mm, and F/ # is 1. 5. The design result was analyzed and evaluated. It was showed that if the slit source, whose width is 50 microm, is used to reconstruction, the theoretic resolution capacity is better than 6.3 nm.

  6. Objectification of facial color inspection to differentiate obstructive/nonobstructive jaundice in neonates by spectrophotometer.

    Science.gov (United States)

    Shen, Zhen; Zheng, Shan; Dong, Rui; Chen, Gong

    2017-12-01

    The purpose of this study was to study whether color difference in facial color truly exists between neonates with obstructive and nonobstructive jaundice, and whether the color difference could be objectified by spectrophotometer. Twelve biliary atresia patients were enrolled in an obstructive jaundice group and 15 neonates admitted for non-conjugated hyperbilirubinemia in a nonobstructive group. Nine patients with syphilis (n=6) and sacrococcygeal teratoma (n=3) were studied as control. Transcutaneous total bilirubin (TB) and hemoglobin were recorded. Face color was measured by spectrophotometer. Spectral reflection curve and L*a*b* model parameters were studied. Facial color of jaundiced neonates were characteristic in waveform that reflectivity at wavelength of 550nm was significantly decreased compared with control by 16.4±3.4%, while not significantly different between obstructive and nonobstructive jaundice (p=0.124). At 650nm, reflection in nonobstructive jaundice was decreased by 8.4±2.3% (pobstructive jaundice (58.09±1.25%)>nonobstructive jaundice (54.25±7.27%). Value b* was higher in jaundiced patients compared to normal control (11.88±2.16, pspectrophotometer. Study of Diagnostic Test. Level II. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. A global algorithm for estimating Absolute Salinity

    Science.gov (United States)

    McDougall, T. J.; Jackett, D. R.; Millero, F. J.; Pawlowicz, R.; Barker, P. M.

    2012-12-01

    The International Thermodynamic Equation of Seawater - 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density) than does Practical Salinity. When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic), Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg-1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p) in the world ocean. To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811). In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally).

  8. [Comparison of color reappearance between metal-ceram restoration and foundry-ceram restoration using crystaleye spectrophotometer].

    Science.gov (United States)

    Shi, Tao; Zhang, Ning; Kong, Fan-wen; Zhan, De-song

    2010-10-01

    To study the color reappearance effect of metal-ceram restoration and foundry-ceram restoration using Crystaleye spectrophotometer. 58 metal-ceram restorations and 58 foundry-ceram restorations according to the result of the Crystaleye spectrophotometer were made respectively. The deltaE between restorations and natural teeth as referenced were analyzed. And satisfaction of dentists and patients were evaluated. The deltaE between metal-ceram restorations and natural teeth was 7.13 +/- 0.74. The deltaE between foundry-ceram restorations and teeth was 1.47 +/- 0.84. There were statistical differences between the deltaE (P spectrophotometer can provide accurate reference for foundry-ceram restoration, but for metal-ceram restoration it is not accurate.

  9. [Precision and accuracy of a dental spectrophotometer in gingival color measurement of maxillary anterior gingival].

    Science.gov (United States)

    Du, Yang; Tan, Jian-guo; Chen, Li; Wang, Fang-ping; Tan, Yao; Zhou, Jian-feng

    2012-08-18

    To explore a gingival shade matching method and to evaluate the precision and accuracy of a dental spectrophotometer modified to be used in gingival color measurement. Crystaleye, a dental spectrophotometer (Olympus, Tokyo, Japan) with a custom shading cover was tested. For precision assessment, two experienced experimenters measured anterior maxillary incisors five times for each tooth. A total of 20 healthy gingival sites (attached gingiva, free gingiva and medial gingival papilla in anterior maxillary region) were measured,the Commission Internationale de I' Eclairage (CIE) color parameters (CIE L*a*b*) of which were analyzed using the supporting software. For accuracy assessment, a rectangular area of approximately 3 mm×3 mm was chosen in the attached gingival portion for spectral analysis. PR715 (SpectraScan;Photo Research Inc.,California, USA), a spectroradiometer, was utilized as standard control. Average color differences (ΔE) between the values from PR715 and Crystaleye were calculated. In precision assessment,ΔL* between the values in all the test sites and average values were from(0.28±0.16)to(0.78±0.57), with Δa*and Δb* from(0.28±0.15)to (0.87±0.65),from(0.19±0.09)to( 0.58±0.78), respectively. Average ΔE between values in all test sites and average values were from (0.62 ± 0.17) to (1.25 ± 0.98) CIELAB units, with a total average ΔE(0.90 ± 0.18). In accuracy assessment, ΔL* with control device were from(0.58±0.50)to(2.22±1.89),with Δa*and Δb* from(1.03±0.67)to(2.99±1.32),from(0.68±0.78)to(1.26±0.83), respectively. Average ΔE with the control device were from (2.44±0.82) to (3.51±1.03) CIELAB units, with a total average ΔE (2.96 ± 1.08). With appropriate modification, Crystaleye, the spectrophotometer, has demonstrated relative minor color variations that can be useful in gingival color measurement.

  10. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  11. Comparing predictive abilities of three visible-near infrared spectrophotometers for soil organic carbon and clay determination

    DEFF Research Database (Denmark)

    Knadel, Maria; Stenberg, Bo; Deng, Fan

    2013-01-01

    carbon (SOC) and clay calibrations for 194 Danish top soils. Scanning procedures for the three spectrophotometers where done according to uniform laboratory protocols. SOC and clay calibrations were performed using PLS regression. One third of the data was used as an independent test set. A range...... of spectral preprocessing methods was applied in search for model improvement. Validation for SOC content using an independent data set derived from all three spectrophotometers provided values of RMSEP between 0.45 and 0.52 %, R2=0.44-0.58 and RPD=1.3-1.5. Clay content was predicted with a higher precision...

  12. The absolute environmental performance of buildings

    DEFF Research Database (Denmark)

    Brejnrod, Kathrine Nykjær; Kalbar, Pradip; Petersen, Steffen

    2017-01-01

    Our paper presents a novel approach for absolute sustainability assessment of a building's environmental performance. It is demonstrated how the absolute sustainable share of the earth carrying capacity of a specific building type can be estimated using carrying capacity based normalization factors....... A building is considered absolute sustainable if its annual environmental burden is less than its share of the earth environmental carrying capacity. Two case buildings – a standard house and an upcycled single-family house located in Denmark – were assessed according to this approach and both were found...... to exceed the target values of three (almost four) of the eleven impact categories included in the study. The worst-case excess was for the case building, representing prevalent Danish building practices, which utilized 1563% of the Climate Change carrying capacity. Four paths to reach absolute...

  13. Absolute calibration technique for spontaneous fission sources

    International Nuclear Information System (INIS)

    Zucker, M.S.; Karpf, E.

    1984-01-01

    An absolute calibration technique for a spontaneously fissioning nuclide (which involves no arbitrary parameters) allows unique determination of the detector efficiency for that nuclide, hence of the fission source strength

  14. MEAN OF MEDIAN ABSOLUTE DERIVATION TECHNIQUE MEAN ...

    African Journals Online (AJOL)

    eobe

    development of mean of median absolute derivation technique based on the based on the based on .... of noise mean to estimate the speckle noise variance. Noise mean property ..... Foraging Optimization,” International Journal of. Advanced ...

  15. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  16. Vulcan - A low-resolution spectrophotometer for measuring the integrated colors of galaxies

    International Nuclear Information System (INIS)

    Rakos, K.D.; Weiss, W.W.; Mueller, S.; Pressberger, R.; Wachtler, P.

    1990-01-01

    Recent advances in fiber optics, holographic gratings, and blue CCD sensitivity have been combined to develop a low-resolution spectrophotometer. Combining the principles of aperture photometry and spectroscopy, this device is designed specifically to measure the light from galaxies with low contrast to the sky brightness (i.e., low surface brightness galaxies). The instrument consists of two large apertures (up to several arcmin) with fast-field lens for imaging the entrance pupil onto a fiber-optics cable. The circular configuration for the input end of the fiber cable is modified to a rectangular slit at the output end. The output is then imaged onto a concave holographic grating producing a spectrum from 3200 A to 7600 A with a resolution of 140 A. The main purpose of this instrument is to obtain narrow-band optical colors for low surface brightness galaxies, which can then be applied to the study of stellar populations in these galaxies. 11 refs

  17. Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

    Science.gov (United States)

    Allen, W. A.; Richardson, A. J.

    1971-01-01

    Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

  18. Evaluation of the LASL automated spectrophotometer for uranium determination at submilligram levels

    International Nuclear Information System (INIS)

    Hollen, R.M.; Jackson, D.D.; Rein, J.E.

    1977-07-01

    The LASL automated spectrophotometer, designed for determination of 1 to 14 mg of uranium and 0.5 to 14 mg of plutonium, has been evaluated for determination of lower levels of uranium to 0.12 mg. The essentially linear response of absorbance is maintained and the standard deviation for a single measurement is constant at about 0.013 mg of uranium, corresponding to a maximum uncertainty of about 10 percent at the 0.12-mg limit. The instrument was applied to the analysis of a series of low-level-concentration, 0.07- to 0.8-mg/ml uranium samples. The results were not statistically different from those obtained by a manual spectrophotometric method

  19. A Study of UV Spectral Transmission Through Different Transparent Media with Spectrophotometer

    Directory of Open Access Journals (Sweden)

    R B Gadgil

    1981-01-01

    Full Text Available This experiment was carried out with the help of spectrophotometer using an artificial UV light source to find -out the percentage transmission of UVA and UVB regions of the UV spectrum. The aim of the experiment was to select the transparent medium which would block mum UVB at the same time allowing mammum UVA to pass through thus reducing the unwanted side effects of UVB light and reducing the efficacy of PUVASOL. It was observed that an ordinary plain 3.3 mm colorless glass was the best transparent medium and with its use a simple solarium could be constructed to treat patients on PUVASOL with sunlight as the source of UV light.

  20. Total ozone trends over the USA during 1979-1991 from Dobson spectrophotometer observations

    Science.gov (United States)

    Komhyr, Walter D.; Grass, Robert D.; Koenig, Gloria L.; Quincy, Dorothy M.; Evans, Robert D.; Leonard, R. Kent

    1994-01-01

    Ozone trends for 1979-1991, determined from Dobson spectrophotometer observations made at eight stations in the United States, are augmented with trend data from four foreign cooperative stations operated by NOAA/CMDL. Results are based on provisional data archived routinely throughout the years at the World Ozone Data Center in Toronto, Canada, with calibration corrections applied to some of the data. Trends through 1990 exhibit values of minus 0.3 percent to minus 0.5 percent yr(exp -1) at mid-to-high latitudes in the northern hemisphere. With the addition of 1991 data, however, the trends become less negative, indicating that ozone increased in many parts of the world during 1991. Stations located within the plus or minus 20 deg N-S latitude band exhibit no ozone trends. Early 1992 data show decreased ozone values at some of the stations. At South Pole, Antarctica, October ozone values have remained low during the past 3 years.

  1. Design and evaluation of an imaging spectrophotometer incorporating a uniform light source.

    Science.gov (United States)

    Noble, S D; Brown, R B; Crowe, T G

    2012-03-01

    Accounting for light that is diffusely scattered from a surface is one of the practical challenges in reflectance measurement. Integrating spheres are commonly used for this purpose in point measurements of reflectance and transmittance. This solution is not directly applicable to a spectral imaging application for which diffuse reflectance measurements are desired. In this paper, an imaging spectrophotometer design is presented that employs a uniform light source to provide diffuse illumination. This creates the inverse measurement geometry to the directional illumination/diffuse reflectance mode typically used for point measurements. The final system had a spectral range between 400 and 1000 nm with a 5.2 nm resolution, a field of view of approximately 0.5 m by 0.5 m, and millimeter spatial resolution. Testing results indicate illumination uniformity typically exceeding 95% and reflectance precision better than 1.7%.

  2. Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.

    Science.gov (United States)

    Desjardins, Philippe; Hansen, Joel B; Allen, Michael

    2009-11-04

    Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.

  3. Lightness, chroma, and hue distributions in natural teeth measured by a spectrophotometer.

    Science.gov (United States)

    Pustina-Krasniqi, Teuta; Shala, Kujtim; Staka, Gloria; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda

    2017-01-01

    The aim of the study was to analyze the distribution of color parameters, lightness (L*), chroma (C), hue (H), a* and b*, in the intercanine sector in maxilla. Patients' tooth color measurements were performed using an intraoral spectrophotometer VITA Easyshade ® (VITA Zahnfabrik H. Rauter GmbH and Co. KG, Bad Sackingen, Germany). The measurements were made in 255 subjects in the intercanine sector in maxilla. The mean values for the group of 255 subjects were as follows: L*, a*, b*, C, and H as 81.6, 0.67, 21.6, 21.7, and 92.7, respectively. For F=206.27 and P < 0.001 between L*, a*, b*, C, H, and central incisor/lateral incisor/canines, there were statistically significant differences. With the statistical analysis, it was determined that there are significant color differences between the teeth of the intercanine sector, which differences are clinically significant also.

  4. Converting a fluorescence spectrophotometer into a three-channel colorimeter for color vision research

    International Nuclear Information System (INIS)

    Pardo, P.J.; Perez, A.L.; Suero, M.I.

    2004-01-01

    An old fluorescence spectrophotometer was recycled to make a three-channel colorimeter. The various modifications involved in its design and implementation are described. An optical system was added that allows the fusion of two visual stimuli coming from the two monochromators of the spectrofluorimeter. Each of these stimuli has a wavelength and bandwidth control, and a third visual stimulus may be taken from a monochromator, a cathode ray tube, a thin film transistor screen, or any other light source. This freedom in the choice of source of the third chromatic channel, together with the characteristics of the visual stimuli from the spectrofluorimeter, give this design a great versatility in its application to novel visual experiments on color vision

  5. Converting a fluorescence spectrophotometer into a three-channel colorimeter for color vision research

    Science.gov (United States)

    Pardo, P. J.; Pérez, A. L.; Suero, M. I.

    2004-01-01

    An old fluorescence spectrophotometer was recycled to make a three-channel colorimeter. The various modifications involved in its design and implementation are described. An optical system was added that allows the fusion of two visual stimuli coming from the two monochromators of the spectrofluorimeter. Each of these stimuli has a wavelength and bandwidth control, and a third visual stimulus may be taken from a monochromator, a cathode ray tube, a thin film transistor screen, or any other light source. This freedom in the choice of source of the third chromatic channel, together with the characteristics of the visual stimuli from the spectrofluorimeter, give this design a great versatility in its application to novel visual experiments on color vision.

  6. Elemental investigation of momordica charantia linn. and syzigium jambolana linn. using atomic absorption spectrophotometer

    International Nuclear Information System (INIS)

    Kazi, T.G.

    2002-01-01

    Elemental investigation of very important medicinal plant i.e. momordica charantia linn and syzigium jambolana linn, and its decoction has been carried out using flame atomic absorption spectrophotometer. In present study fifteen essential, trace and toxic elements such as Zn, Cr, K, Mg, Ca, Na, Cu, Fe, Pb, Al, Ba, Mn, Co, Ni and Cd were determined in different parts of both plants and in its decoction. The level of essential elements was found high as compared to the level of toxic elements. Both plants are useful in the treatment of diabetes. The validation of the method was checked by employing NBS- 1570 (Spanish) as a standard reference material . The measured values of elements are in close agreement with certified values. (author)

  7. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  8. Assessing the Engagement, Learning, and Overall Experience of Students Operating an Atomic Absorption Spectrophotometer with Remote Access Technology

    Science.gov (United States)

    Erasmus, Daniel J.; Brewer, Sharon E.; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of…

  9. Development of a low-cost NIR instrument for minced meat analysis: Part 1 - Spectrophotometer and sample presentations

    Science.gov (United States)

    The feasibility of using a compact, low-cost NIR spectrophotometer to predict moisture (MC) and total fat content of minced pork was demonstrated. Results were compared with those obtained using two research type instruments with high signal to noise ratio (S/N). The NIR measuring head of the compac...

  10. Photochemical induced growth and aggregation of metal nanoparticles in diode-array spectrophotometer via excited dimethyl-sulfoxide.

    Science.gov (United States)

    Zidki, Tomer; Cohen, Haim; Meyerstein, Dan

    2010-10-21

    Ag(0) and Au(0) nanoparticles suspended in dilute aqueous solutions containing (CH(3))(2)SO are photochemically unstable. The light source of a diode-array spectrophotometer induces, within less than a minute, particle growth and aggregation. The results indicate that this process is triggered by UV light absorption by the (CH(3))(2)SO.

  11. A low cost short wave near infrared spectrophotometer: application for determination of quality parameters of diesel fuel.

    Science.gov (United States)

    Gonzaga, Fabiano Barbieri; Pasquini, Celio

    2010-06-18

    A low cost absorption spectrophotometer for the short wave near infrared spectral region (850-1050 nm) is described. The spectrophotometer is basically composed of a conventional dichroic lamp, a long-pass filter, a sample cell and a Czerny-Turner type polychromator coupled to a 1024 pixel non-cooled photodiode array. A preliminary evaluation of the spectrophotometer showed good repeatability of the first derivative of the spectra at a constant room temperature and the possibility of assigning some spectral regions to different C-H stretching third overtones. Finally, the spectrophotometer was successfully applied for the analysis of diesel samples and the determination of some of their quality parameters using partial least squares calibration models. The values found for the root mean square error of prediction using external validation were 0.5 for the cetane index and from 2.5 to 5.0 degrees C for the temperatures achieved during distillation when obtaining 10, 50, 85, and 90% (v/v) of the distilled sample, respectively. 2010 Elsevier B.V. All rights reserved.

  12. Demonstrating Principles of Spectrophotometry by Constructing a Simple, Low-Cost, Functional Spectrophotometer Utilizing the Light Sensor on a Smartphone

    Science.gov (United States)

    Hosker, Bill S.

    2018-01-01

    A highly simplified variation on the do-it-yourself spectrophotometer using a smartphone's light sensor as a detector and an app to calculate and display absorbance values was constructed and tested. This simple version requires no need for electronic components or postmeasurement spectral analysis. Calibration graphs constructed from two…

  13. Absolute isotopic abundances of Ti in meteorites

    International Nuclear Information System (INIS)

    Niederer, F.R.; Papanastassiou, D.A.; Wasserburg, G.J.

    1985-01-01

    The absolute isotope abundance of Ti has been determined in Ca-Al-rich inclusions from the Allende and Leoville meteorites and in samples of whole meteorites. The absolute Ti isotope abundances differ by a significant mass dependent isotope fractionation transformation from the previously reported abundances, which were normalized for fractionation using 46 Ti/ 48 Ti. Therefore, the absolute compositions define distinct nucleosynthetic components from those previously identified or reflect the existence of significant mass dependent isotope fractionation in nature. We provide a general formalism for determining the possible isotope compositions of the exotic Ti from the measured composition, for different values of isotope fractionation in nature and for different mixing ratios of the exotic and normal components. The absolute Ti and Ca isotopic compositions still support the correlation of 50 Ti and 48 Ca effects in the FUN inclusions and imply contributions from neutron-rich equilibrium or quasi-equilibrium nucleosynthesis. The present identification of endemic effects at 46 Ti, for the absolute composition, implies a shortfall of an explosive-oxygen component or reflects significant isotope fractionation. Additional nucleosynthetic components are required by 47 Ti and 49 Ti effects. Components are also defined in which 48 Ti is enhanced. Results are given and discussed. (author)

  14. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  15. Redetermination and absolute configuration of atalaphylline

    Directory of Open Access Journals (Sweden)

    Hoong-Kun Fun

    2010-02-01

    Full Text Available The title acridone alkaloid [systematic name: 1,3,5-trihydroxy-2,4-bis(3-methylbut-2-enylacridin-9(10H-one], C23H25NO4, has previously been reported as crystallizing in the chiral orthorhombic space group P212121 [Chantrapromma et al. (2010. Acta Cryst. E66, o81–o82] but the absolute configuration could not be determined from data collected with Mo radiation. The absolute configuration has now been determined by refinement of the Flack parameter with data collected using Cu radiation. All features of the molecule and its crystal packing are similar to those previously described.

  16. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    Science.gov (United States)

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  17. Det demokratiske argument for absolut ytringsfrihed

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2014-01-01

    Artiklen diskuterer den påstand, at absolut ytringsfrihed er en nødvendig forudsætning for demokratisk legitimitet med udgangspunkt i en rekonstruktion af et argument fremsat af Ronald Dworkin. Spørgsmålet er, hvorfor ytringsfrihed skulle være en forudsætning for demokratisk legitimitet, og hvorfor...

  18. Musical Activity Tunes Up Absolute Pitch Ability

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Ribe, Lars Riisgaard

    2014-01-01

    Absolute pitch (AP) is the ability to identify or produce pitches of musical tones without an external reference. Active AP (i.e., pitch production or pitch adjustment) and passive AP (i.e., pitch identification) are considered to not necessarily coincide, although no study has properly compared...

  19. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  20. Absolute measurement of a tritium standard

    International Nuclear Information System (INIS)

    Hadzisehovic, M.; Mocilnik, I.; Buraei, K.; Pongrac, S.; Milojevic, A.

    1978-01-01

    For the determination of a tritium absolute activity standard, a method of internal gas counting has been used. The procedure involves water reduction by uranium and zinc further the measurement of the absolute disintegration rate of tritium per unit of the effective volume of the counter by a compensation method. Criteria for the choice of methods and procedures concerning the determination and measurement of gaseous 3 H yield, parameters of gaseous hydrogen, sample mass of HTO and the absolute disintegration rate of tritium are discussed. In order to obtain gaseous sources of 3 H (and 2 H), the same reversible chemical reaction was used, namely, the water - uranium hydride - hydrogen system. This reaction was proved to be quantitative above 500 deg C by measuring the yield of the gas obtained and the absolute activity of an HTO standard. A brief description of the measuring apparatus is given, as well as a critical discussion of the brass counter quality and the possibility of obtaining equal working conditions at the counter ends. (T.G.)

  1. Absolutyzm i pluralizm (ABSOLUTISM AND PLURALISM

    Directory of Open Access Journals (Sweden)

    Renata Ziemińska

    2005-06-01

    Full Text Available Alethic absolutism is a thesis that propositions can not be more or less true, that they are true or false for ever (if true at all and that their truth is independent on any circumstances of their assertion. In negative version, easier to defend, alethic absolutism claims the very same proposition can not be both true and false relative to circumstances of its assertion. Simple alethic pluralism is a thesis that we have many concepts of truth. It is a very good way to dissolve the controversy between alethic relativism and absolutism. Many philosophical concepts of truth are the best reason for such pluralism. If concept is meaning of a name, we have many concepts of truth because the name 'truth' was understood in many ways. The variety of meanings however can be superficial. Under it we can find one idea of truth expressed in correspondence truism or schema (T. The content of the truism is too poor to be content of anyone concept of truth, so it usually is connected with some picture of the world (ontology and we have so many concepts of truth as many pictures of the world. The authoress proposes the hierarchical pluralism with privileged classic (or correspondence in weak sense concept of truth as absolute property.Other author's publications:

  2. Absolute Distance Measurements with Tunable Semiconductor Laser

    Czech Academy of Sciences Publication Activity Database

    Mikel, Břetislav; Číp, Ondřej; Lazar, Josef

    T118, - (2005), s. 41-44 ISSN 0031-8949 R&D Projects: GA AV ČR(CZ) IAB2065001 Keywords : tunable laser * absolute interferometer Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  3. Thin-film magnetoresistive absolute position detector

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1990-01-01

    The subject of this thesis is the investigation of a digital absolute posi- tion-detection system, which is based on a position-information carrier (i.e. a magnetic tape) with one single code track on the one hand, and an array of magnetoresistive sensors for the detection of the information on the

  4. Stimulus Probability Effects in Absolute Identification

    Science.gov (United States)

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  5. Absolute tightness: the chemists hesitate to invest

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The safety requirements of industries as nuclear plants and the strengthening of regulations in the field of environment (more particularly those related to volatile organic compounds) have lead the manufacturers to build absolute tightness pumps. But these equipments do not answer all the problems and represent a high investment cost. In consequence, the chemists hesitate to invest. (O.L.)

  6. Solving Absolute Value Equations Algebraically and Geometrically

    Science.gov (United States)

    Shiyuan, Wei

    2005-01-01

    The way in which students can improve their comprehension by understanding the geometrical meaning of algebraic equations or solving algebraic equation geometrically is described. Students can experiment with the conditions of the absolute value equation presented, for an interesting way to form an overall understanding of the concept.

  7. A study of a sector spectrophotometer and auroral O+(2P-2D) emissions

    Science.gov (United States)

    Swenson, G. R.

    1976-01-01

    The metastable O+(2P-2D) auroral emission was investigated. The neighboring OH contaminants and low intensity levels of the emission itself necessitated the evolution of an instrument capable of separating the emission from the contaminants and having a high sensitivity in the wavelength region of interest. A new type of scanning photometer was developed and its properties are discussed. The theoretical aspects of auroral electron interaction with atomic oxygen and the resultant O+(2P-2D) emissions were examined in conjunction with N2(+)1NEG emissions. Ground based measurements of O+(2P-2D) auroral emission intensities were made using the spatial scanning photometer (sector spectrophotometer). Simultaneous measurements of N2(+)1NEG sub 1,0 emission intensity were made in the same field of view using a tilting photometer. Time histories of the ratio of these two emissions made in the magnetic zenith during auroral breakup periods are given. Theories of I sub 7319/I sub 4278 of previous investigators were presented. A rocket measurement of N2(+)1NEG sub 0,0 and O+(2P-2D) emission in aurora was examined in detail and was found to agree with the ground based measurements. Theoretical examination resulted in the deduction of the electron impact efficiency generating O+(2P) and also suggests a large source of O+(2P) at low altitude. A possible source is charge exchange of N+(1S) with OI(3P).

  8. Outdoor solar UVA dose assessment with EBT2 radiochromic film using spectrophotometer and densitometer measurements

    International Nuclear Information System (INIS)

    Abukassem, I.; Bero, M.A.

    2015-01-01

    Direct measurements of solar ultraviolet radiations (UVRs) have an important role in the protection of humans against UVR hazard. This work presents simple technique based on the application of EBT2 GAFCHROMIC R film for direct solar UVA dose assessment. It demonstrates the effects of different parts of the solar spectrum (UVB, visible and infrared) on performed UVA field measurements and presents the measurement uncertainty budget. The gradient of sunlight exposure level permitted the authors to establish the mathematical relationships between the measured solar UVA dose and two measured quantities: the first was the changes in spectral absorbance at the wavelength 633 nm (A 633 ) and the second was the optical density (OD). The established standard relations were also applied to calculate the solar UVA dose variations during the whole day; 15 min of exposure each hour between 8:00 and 17:00 was recorded. Results show that both applied experimental methods, spectrophotometer absorbance and densitometer OD, deliver comparable figures for EBT2 solar UVA dose assessment with relative uncertainty of 11 % for spectral absorbance measurements and 15 % for OD measurements. (authors)

  9. Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions.

    Science.gov (United States)

    Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming

    2016-06-29

    On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01-0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics.

  10. Determination of nanomolar chromate in drinking water with solid phase extraction and a portable spectrophotometer.

    Science.gov (United States)

    Ma, Jian; Yang, Bo; Byrne, Robert H

    2012-06-15

    Determination of chromate at low concentration levels in drinking water is an important analytical objective for both human health and environmental science. Here we report the use of solid phase extraction (SPE) in combination with a custom-made portable light-emitting diode (LED) spectrophotometer to achieve detection of chromate in the field at nanomolar levels. The measurement chemistry is based on a highly selective reaction between 1,5-diphenylcarbazide (DPC) and chromate under acidic conditions. The Cr-DPC complex formed in the reaction can be extracted on a commercial C18 SPE cartridge. Concentrated Cr-DPC is subsequently eluted with methanol and detected by spectrophotometry. Optimization of analytical conditions involved investigation of reagent compositions and concentrations, eluent type, flow rate (sample loading), sample volume, and stability of the SPE cartridge. Under optimized conditions, detection limits are on the order of 3 nM. Only 50 mL of sample is required for an analysis, and total analysis time is around 10 min. The targeted analytical range of 0-500 nM can be easily extended by changing the sample volume. Compared to previous SPE-based spectrophotometric methods, this analytical procedure offers the benefits of improved sensitivity, reduced sample consumption, shorter analysis time, greater operational convenience, and lower cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. [Determination of soil exchangeable base cations by using atomic absorption spectrophotometer and extraction with ammonium acetate].

    Science.gov (United States)

    Zhang, Yu-ge; Xiao, Min; Dong, Yi-hua; Jiang, Yong

    2012-08-01

    A method to determine soil exchangeable calcium (Ca), magnesium (Mg), potassium (K), and sodium (Na) by using atomic absorption spectrophotometer (AAS) and extraction with ammonium acetate was developed. Results showed that the accuracy of exchangeable base cation data with AAS method fits well with the national standard referential soil data. The relative errors for parallel samples of exchangeable Ca and Mg with 66 pair samples ranged from 0.02%-3.14% and 0.06%-4.06%, and averaged to be 1.22% and 1.25%, respectively. The relative errors for exchangeable K and Na with AAS and flame photometer (FP) ranged from 0.06%-8.39% and 0.06-1.54, and averaged to be 3.72% and 0.56%, respectively. A case study showed that the determination method for exchangeable base cations by using AAS was proven to be reliable and trustable, which could reflect the real situation of soil cation exchange properties in farmlands.

  12. Outdoor solar UVA dose assessment with EBT2 radiochromic film using spectrophotometer and densitometer measurements.

    Science.gov (United States)

    Abukassem, I; Bero, M A

    2015-04-01

    Direct measurements of solar ultraviolet radiations (UVRs) have an important role in the protection of humans against UVR hazard. This work presents simple technique based on the application of EBT2 GAFCHROMIC(®) film for direct solar UVA dose assessment. It demonstrates the effects of different parts of the solar spectrum (UVB, visible and infrared) on performed UVA field measurements and presents the measurement uncertainty budget. The gradient of sunlight exposure level permitted the authors to establish the mathematical relationships between the measured solar UVA dose and two measured quantities: the first was the changes in spectral absorbance at the wavelength 633 nm (A633) and the second was the optical density (OD). The established standard relations were also applied to calculate the solar UVA dose variations during the whole day; 15 min of exposure each hour between 8:00 and 17:00 was recorded. Results show that both applied experimental methods, spectrophotometer absorbance and densitometer OD, deliver comparable figures for EBT2 solar UVA dose assessment with relative uncertainty of 11% for spectral absorbance measurements and 15% for OD measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction.

    Science.gov (United States)

    Yang, Fangwen; Liu, Rui; Tan, Zhiqiang; Wen, Xiaodong; Zheng, Chengbin; Lv, Yi

    2010-11-15

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl(4) (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I(0) and I(i)) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L(-1), with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L(-1). The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water). Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction

    International Nuclear Information System (INIS)

    Yang Fangwen; Liu Rui; Tan Zhiqiang; Wen Xiaodong; Zheng Chengbin; Lv Yi

    2010-01-01

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl 4 (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I 0 and I i ) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L -1 , with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L -1 . The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water).

  15. The Soft X-ray Spectrophotometer SphinX for the CORONAS-Photon Mission

    Science.gov (United States)

    Sylwester, Janusz; Kowalinski, Miroslaw; Szymon, Gburek; Bakala, Jaroslaw; Kuzin, Sergey; Kotov, Yury; Farnik, Frantisek; Reale, Fabio

    The purpose, construction details and calibration results of the new design, Polish-led solar X-ray spectrophotometer SphinX will be presented. The instrument constitutes a part of the Russian TESIS X-ray and EUV complex aboard the forthcoming CORONAS-Photon solar mission to be launched later in 2008. SphinX uses Si-PIN detectors for high time resolution (down to 0.01 s) measurements of solar spectra in the energy range between 0.5 keV and 15 keV. The spectral resolution allows separating 256 individual energy channels in this range with particular groups of lines clearly distinguishable. Unprecedented accuracy of the instrument calibration at the XACT (Palermo) and BESSY (Berlin) synchrotron will allow for establishing the solar soft X-ray photometric reference system. The cross-comparison between SphinX and the other instruments presently in orbit like XRT on Hinode, RHESSI and GOES X-ray monitor, will allow for a precise determination of the coronal emission measure and temperature during both very low and very high activity periods. Examples of the detectors' ground calibration results as well as the calculated synthetic spectra will be presented. The operation of the instrument while in orbit will be discussed allowing for suggestions from other groups to be still included in mission planning.

  16. Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions

    Science.gov (United States)

    Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming

    2016-06-01

    On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01-0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics.

  17. Validation of the method spectrophotometer in the histamine determination in fresh tuna (Thunnus Tunna)

    International Nuclear Information System (INIS)

    Chacon Silva, F.

    1998-01-01

    The objective of this study was to validate the spectrophotometer method described by Bateman et al. (1994) for the histamine determination in fresh tuna (Thunnus Tunna) and to evaluate the histamine concentration in samples of fresh tuna. To fulfill the recently exposed objectives, the figures of merit were determined like they are it: recovery limits of detection, sensibility and repetitive of the method spectrophotometry and applied the analysis at twenty samples of fresh tuna for copy of the Metropolitan area and three sample like reference of fresh tuna stored 4 degree centigrade by 15 days. The histamine recovery you determines enriching seven ours of fresh tuna with histamine to two levels different 0.613 mg/L and 2.21 mg/L. three samples were left without enriching and you subtract the average to the native histamine. You determines the one it limits of detection using the standard deviation to three levels of concentration of histamine 1.37 mg/L, 2.22 mg/L and 3.22 mg/L, the minimum quantity of hi stamina that you can determine for the method spectrophotometry settling down. The repetitive you determines using the standard deviation for 100 among the average of the histamine values, in seven you replies independent of the same sample. You determines the histamine content, in the fresh tuna Thunnus Tunna of the expends of the Metropolitan Area and in samples of reference stored 4 degrees centigrade by 15 days [es

  18. Spectrophotometer as a tool for analysis of various species in radioactive liquid wastes (Preprint No. RA-27)

    International Nuclear Information System (INIS)

    Yeotikar, R.G.; Kaushik, C.P.; Raj, Kanwar

    1988-02-01

    For the immobilisation of high level radioactive liquid waste in a glass matrix, the analysis of different species in the waste is the primary requirement for fixing the base composition of glass. The commercially available spectrophotometer has been remotised to facilitate the analysis of different radioactive streams. Methods for analysis of constituents such as Fe, Mo, Cr, U, total lanthanides, Zr and PO4 have been established. (author)

  19. Roughened glass slides and a spectrophotometer for the detection of the wavelength-dependent refractive index of transparent liquids.

    Science.gov (United States)

    Niskanen, Ilpo; Räty, Jukka; Myllylä, Risto; Sutinen, Veijo; Matsuda, Kiyofumi; Homma, Kazuhiro; Silfsten, Pertti; Peiponen, Kai-Erik

    2012-07-01

    We describe a method to determine the wavelength-dependent refractive index of liquids by measurement of light transmittance with a spectrophotometer. The method is based on using roughened glass slides with different a priori known refractive indices and immersing the slides into the transparent liquid with unknown refractive index. Using the dispersion data on the glass material it is possible to find the index match between the liquid and the glass slide, and hence the refractive index of the liquid.

  20. Near-IR laser-based spectrophotometer for comparative analysis of isotope content of CO2 in exhale air samples

    International Nuclear Information System (INIS)

    Stepanov, E V; Glushko, A N; Kasoev, S G; Koval', A V; Lapshin, D A

    2011-01-01

    We present a laser spectrophotometer aimed at high-accuracy comparative analysis of content of 12 CO 2 and 13 CO 2 isotope modifications in the exhale air samples and based on a tunable near-IR diode laser (2.05 μm). The two-channel optical scheme of the spectrophotometer and the special digital system for its control are described. An algorithm of spectral data processing aimed at determining the difference in the isotope composition of gas mixtures is proposed. A few spectral regions (near 4880 cm -1 ) are determined to be optimal for analysis of relative content of 12 CO 2 and 13 CO 2 in the exhale air. The use of the proposed spectrophotometer scheme and the developed algorithm makes the results of the analysis less susceptible to the influence of the interference in optical elements, to the absorption in the open atmosphere, to the slow drift of the laser pulse envelope, and to the offset of optical channels. The sensitivity of the comparative analysis of the isotope content of CO 2 in exhale air samples, achieved using the proposed scheme, is estimated to be nearly 0.1‰.

  1. Study of the influence of substrate and spectrophotometer characteristics on the in vitro measurement of sunscreens efficiency.

    Science.gov (United States)

    Couteau, C; Philippe, A; Vibet, M-A; Paparis, E; Coiffard, L

    2018-05-16

    All the methods used for the in vitro measurement of the SPF, the universal indicator of sunscreens efficiency, rely on a spectrophotometric analysis. What can vary about the experimental protocol used is mainly the substrate and the type of spectrophotometer chosen. We decided to work with polymethylmetacrylate plates that we analyzed using two spectrophotometers equipped with integrating spheres, the UV1000S and the UV2000 apparatus. Two marketed products were such tested, after spreading 2 mg/cm 2 on the plates, using one apparatus after another. We applied a non-parametric Wilcoxon test for paired data to the measures realized on 10 plates (as we systematically used the 2 apparatus), in order to compare the series of measures obtained with the two machines. This way, we were able to show a significant difference between the SPF values respectively obtained with the UV1000S and the UV2000 spectrophotometers. This difference could be explained by the decrease of the stray light in the case of the UV2000 apparatus. Copyright © 2017. Published by Elsevier B.V.

  2. Low-cost, digital lock-in module with external reference for coating glass transmission/reflection spectrophotometer

    Science.gov (United States)

    Alonso, R.; Villuendas, F.; Borja, J.; Barragán, L. A.; Salinas, I.

    2003-05-01

    A versatile, low-cost, digital signal processor (DSP) based lock-in module with external reference is described. This module is used to implement an industrial spectrophotometer for measuring spectral transmission and reflection of automotive and architectonic coating glasses over the ultraviolet, visible and near-infrared wavelength range. The light beams are modulated with an optical chopper. A digital phase-locked loop (DPLL) is used to lock the lock-in to the chop frequency. The lock-in rejects the ambient radiation and permits the spectrophotometer to work in the presence of ambient light. The algorithm that implements the dual lock-in and the DPLL in the DSP56002 evaluation module from Motorola is described. The use of a DSP allows implementation of the lock-in and DPLL by software, which gives flexibility and programmability to the system. Lock-in module cost, under 300 euro, is an important parameter taking into account that two modules are used in the system. Besides, the algorithms implemented in this DSP can be directly implemented in the latest DSP generations. The DPLL performance and the spectrophotometer are characterized. Capture and lock DPLL ranges have been measured and checked to be greater than the chop frequency drifts. The lock-in measured frequency response shows that the lock-in performs as theoretically predicted.

  3. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  4. Absolute-magnitude distributions of supernovae

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Dean; Wright, John [Department of Physics, Xavier University of Louisiana, New Orleans, LA 70125 (United States); Jenkins III, Robert L. [Applied Physics Department, Richard Stockton College, Galloway, NJ 08205 (United States); Maddox, Larry, E-mail: drichar7@xula.edu [Department of Chemistry and Physics, Southeastern Louisiana University, Hammond, LA 70402 (United States)

    2014-05-01

    The absolute-magnitude distributions of seven supernova (SN) types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M{sub B} < –21) make up only about 0.1% of all SNe in the bias-corrected sample. The subluminous events (M{sub B} > –15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of –19.25. The IIP distribution was the dimmest at –16.75.

  5. Absolute and relative dosimetry for ELIMED

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics Czech Academy of Science, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Leonora, E.; Randazzo, N. [INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Presti, D. Lo [INFN-Sezione di Catania, Via Santa Sofia 64, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Raffaele, L. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Tramontana, A. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Cirio, R.; Sacchi, R.; Monaco, V. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino, Italy and Università di Torino, Dipartimento di Fisica, Via P.Giuria, 1 10125 Torino (Italy); Marchetto, F.; Giordanengo, S. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino (Italy)

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  6. Absolute photoionization cross sections of atomic oxygen

    Science.gov (United States)

    Samson, J. A. R.; Pareek, P. N.

    1985-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  7. Absolute purchasing power parity in industrial countries

    OpenAIRE

    Zhang, Zhibai; Bian, Zhicun

    2015-01-01

    Different from popular studies that focus on relative purchasing power parity, we study absolute purchasing power parity (APPP) in 21 main industrial countries. Three databases are used. Both the whole period and the sub-period are analyzed. The empirical proof shows that the phenomenon that APPP holds is common, and the phenomenon that APPP does not hold is also common. In addition, some country pairs and the pooled country data indicate that the nearer the GDPPs of two countries are, the mo...

  8. Internal descriptions of absolute Borel classes

    Czech Academy of Sciences Publication Activity Database

    Holický, P.; Pelant, Jan

    2004-01-01

    Roč. 141, č. 1 (2004), s. 87-104 ISSN 0166-8641 R&D Projects: GA ČR GA201/00/1466; GA ČR GA201/03/0933 Institutional research plan: CEZ:AV0Z1019905 Keywords : absolute Borel class * complete sequence of covers * open map Subject RIV: BA - General Mathematics Impact factor: 0.364, year: 2004

  9. The absolute differential calculus calculus of tensors

    CERN Document Server

    Levi-Cività, Tullio

    1926-01-01

    Written by a towering figure of twentieth-century mathematics, this classic examines the mathematical background necessary for a grasp of relativity theory. Tullio Levi-Civita provides a thorough treatment of the introductory theories that form the basis for discussions of fundamental quadratic forms and absolute differential calculus, and he further explores physical applications.Part one opens with considerations of functional determinants and matrices, advancing to systems of total differential equations, linear partial differential equations, algebraic foundations, and a geometrical intro

  10. An absolute deviation approach to assessing correlation.

    OpenAIRE

    Gorard, S.

    2015-01-01

    This paper describes two possible alternatives to the more traditional Pearson’s R correlation coefficient, both based on using the mean absolute deviation, rather than the standard deviation, as a measure of dispersion. Pearson’s R is well-established and has many advantages. However, these newer variants also have several advantages, including greater simplicity and ease of computation, and perhaps greater tolerance of underlying assumptions (such as the need for linearity). The first alter...

  11. Benzofuranoid and bicyclooctanoid neolignans:absolute configuration

    International Nuclear Information System (INIS)

    Alvarenga, M.A. de; Giesbrecht, A.M.; Gottlieb, O.R.; Yoshida, M.

    1977-01-01

    The naturally occuring benzofuranoid and bicyclo (3,2,1) octanoid neolignans have their relative configurations established by 1 H and 13 C NMR, inclusively with aid of the solvent shift technique. Interconversion of the benzofuranoid type compounds, as well as for a benzofuranoid to a bicyclooctanoid derivate, make ORD correlations, ultimately with (2S, 3S) - and (2R,3R)-2,3- dihydrobenzofurans, possible, and led to the absolute configurations of both series of neolignans [pt

  12. Least Squares Problems with Absolute Quadratic Constraints

    Directory of Open Access Journals (Sweden)

    R. Schöne

    2012-01-01

    Full Text Available This paper analyzes linear least squares problems with absolute quadratic constraints. We develop a generalized theory following Bookstein's conic-fitting and Fitzgibbon's direct ellipse-specific fitting. Under simple preconditions, it can be shown that a minimum always exists and can be determined by a generalized eigenvalue problem. This problem is numerically reduced to an eigenvalue problem by multiplications of Givens' rotations. Finally, four applications of this approach are presented.

  13. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  14. Comparison of Ozone Retrievals from the Pandora Spectrometer System and Dobson Spectrophotometer in Boulder, Colorado

    Science.gov (United States)

    Herman, J.; Evans, R.; Cede, A.; Abuhassan, N.; Petropavlovskikh, I.; McConville, G.

    2015-01-01

    A comparison of retrieved total column ozone (TCO) amounts between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado, NOAA building. This paper, part of an ongoing study, covers a 1-year period starting on 17 December 2013. Both the standard Dobson and Pandora TCO retrievals required a correction, TCO(sub corr) = TCO (1 + C(T)), using a monthly varying effective ozone temperature, T(sub E), derived from a temperature and ozone profile climatology. The correction is used to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T(sub E)) are C(sub Pandora) = 0.00333(T(sub E) - 225) and C(sub Dobson) = -0.0013(T(sub E) - 226.7) per degree K. After the applied corrections removed most of the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r(exp 2) = 0.97 and an average offset of 1.1 +/- 5.8 DU. In addition, the Pandora TCO data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).

  15. Comparison between Brewer spectrometer, M 124 filter ozonometer and Dobson spectrophotometer

    Science.gov (United States)

    Feister, U.

    1994-01-01

    Concurrent measurements were taken using the Brewer spectrometer no. 30, the filter ozonometer M 124 no. 200 and the Dobson spectrophotometer no. 71 from September 1987 to December 1988 at Potsdam. The performance of the instrument types and the compatibility of ozone data was checked under the conditions of a field measuring station. Total ozone values derived from Dobson AD direct sun measurements were considered as standard. The Dobson instrument had been calibrated at intercomparisons with the World Standard Dobson instrument no. 83 (Boulder) and with the Regional Standard instrument no. 64 (Potsdam), while the Brewer instrument was calibrated several times with the Travelling Standard Brewer no. 17 (Canada). The differences between individual Brewer DS (direct sun) ozone data and Dobson ADDS are within plus or minus 3 percent with half of all differences within plus or minus 1 percent. Less than 0.7 percent of the systematic difference can be due to atmospheric SO2. Due to inadequate regression coefficients Brewer ZB (zenith blue) ozone measurements are by (3...4) percent higher than Dobson ADDS ozone values. M124 DS ozone data are systematically by (1...2) percent higher than Dobson ADDS ozone with 50 percent of the differences within plus or minus 4 percent, but with extreme differences up to plus or minus (20...25) percent. M124 ZB ozone values are by (3...5) percent higher than Dobson ADDS with all the differences within plus or minus 10 percent, i.e. the scatter of differences is smaller for ZB than for M 124 DS measurements, Results for differences in the daily mean ozone values are also addressed. The differences include the uncertainties in the ozone values derived from both types of measurements. They provide an indication of the uncertainty in ozone data and the comparability of ozone values derived from different types of instruments.

  16. Non-destructive assessment of grapevine water status in the field using a portable NIR spectrophotometer.

    Science.gov (United States)

    Tardaguila, Javier; Fernández-Novales, Juan; Gutiérrez, Salvador; Diago, Maria Paz

    2017-08-01

    Until now, the majority of methods employed to assess grapevine water status have been destructive, time-intensive, costly and provide information of a limited number of samples, thus the ability of revealing within-field water status variability is reduced. The goal of this work was to evaluate the capability of non-invasive, portable near infrared (NIR) spectroscopy acquired in the field, to assess the grapevine water status in diverse varieties, grown under different environmental conditions, in a fast and reliable way. The research was conducted 2 weeks before harvest in 2012, in two commercial vineyards, planted with eight different varieties. Spectral measurements were acquired in the field on the adaxial and abaxial sides of 160 individual leaves (20 leaves per variety) using a commercially available handheld spectrophotometer (1600-2400 nm). Principal component analysis (PCA) and modified partial least squares (MPLS) were used to interpret the spectra and to develop reliable prediction models for stem water potential (Ψ s ) (cross-validation correlation coefficient (r cv ) ranged from 0.77 to 0.93, and standard error of cross validation (SECV) ranged from 0.10 to 0.23), and leaf relative water content (RWC) (r cv ranged from 0.66 to 0.81, and SECV between 1.93 and 3.20). The performance differences between models built from abaxial and adaxial-acquired spectra is also discussed. The capability of non-invasive NIR spectroscopy to reliably assess the grapevine water status under field conditions was proved. This technique can be a suitable and promising tool to appraise within-field variability of plant water status, helpful to define optimised irrigation strategies in the wine industry. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. Comparison of Shade of Ceramic with Three Different Zirconia Substructures using Spectrophotometer.

    Science.gov (United States)

    Habib, Syed Rashid; Shiddi, Ibraheem F Al

    2015-02-01

    This study assessed how changing the Zirconia (Zr) substructure affected the color samples after they have been overlaid by the same shade of veneering ceramic. Three commercial Zr materials were tested in this study: Prettau(®) Zirconia (ZirKonZahn, Italy), Cercon (Dentsply, Germany) and InCoris ZI (Sirona, Germany). For each system, 15 disk-shaped specimens (10 × 1 mm) were fabricated. Three shades of A1, A2 and A3.5 of porcelain (IPS e.MaxCeram, IvoclarVivadent, USA) were used for layering the specimens. Five specimens from each type of Zr were layered with same shade of ceramic. Color measurements were recorderd by a spectrophotometer Color-Eye(®) 7000A (X-Rite, Grand Rapids, MI). Mean values of L, a, b color coordinates and ΔE were recorded and comparisons were made. Differences in the ΔE were recorded for the same porcelain shade with different Zr substructures and affected the color of the specimens (p < 0.01, ANOVA). The maximum difference between the ΔE values for the A1, A2 and A3.5 shades with three types of Zr substructures was found to be 1.59, 1.69 and 1.45 respectively. Multiple comparisons of the ΔE with PostHoc Tukey test revealed a statistically significant difference (p < 0.05) between the three types of Zr, except between Type 2 Zr and Type 3 Zr for the Shade A1. The mean values of L, a, b and ΔE for the Prettau(®) Zirconia substructure were found to be the least among the three types. The brand of Zr used influences the final color of the all ceramic Zr based restorations and this has clinical significance.

  18. Measurement of breast milk intake using deuterium oxide and fourier transformed infrared spectrophotometer - a pilot study

    International Nuclear Information System (INIS)

    Adom, T.; Bansa, D.; Boatin, R.; Vuore, T.; Datohe, D.; Timpo, S.; Asamoa-Tutu, P.

    2011-01-01

    The measurement of breast milk intake of infants is essential to the estimation of nutrient requirements during infancy and lactation. The conventional method, test-weighing procedure for measuring breast milk is time consuming, most often inaccurate and may interfere with the mother's normal activities. A more practical and accurate method is isotope dilution using stable isotope-labelled water. The accuracy and ready availability of deuterium oxide (D 2 O) have led to its extensive use in measuring body composition and breast milk intake of infants. The D 2 O turnover method was field-tested in 13 lactating Ghanaian mother-baby pairs. Maternal and baby anthropometric measurements were made. Baby milk intake and maternal body composition were measured with the dose-to-mother method. Pre-dose samples of saliva were taken from each mother-baby pair. A measured D 2 O dose (30g) was administered orally to the mother. Post-dose saliva samples were collected from mother and baby on days 1, 2, 3, 4, 13, and 14. Samples were analysed using Fourier Transformed Infrared Spectrophotometer (FTIR). The mean ± SD maternal age was 24 ± 5 years. Babies were aged 3.5 months on the average and weighed 6.7 ± 0.7 kg. Mean milk intake of babies was 828 ± 132 ml/day with a range of 610 to 1040 ml/day. Maternal fat free mass and % body fat were 44.8 ± 5.3 kg, 23.1 ± 5.1 respectively. This non-invasive and convenient method has been used successfully to measure breast milk intake of Ghanaian infants. (au)

  19. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  20. Absolute measurement of environmental radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1987-01-01

    A transportable meter for environmental radon measurement with a 40 liter decay chamber is designed on the principle of Thomas two-filter radon content absolute measurement. The sensitivity is 0.37 Bq·m -3 with 95% confidence level. This paper describes the experimental method of measuremment and it's intrinsic uncertainty. The typical intrinsic uncertainty (for n x 3.7 Bq·m -3 radon concentration) is <10%. The parameter of exit filter effeciency is introduced into the formula, and the verification is done for the case when the diameter of the exit filter is much less than the inlet one

  1. Fractional order absolute vibration suppression (AVS) controllers

    Science.gov (United States)

    Halevi, Yoram

    2017-04-01

    Absolute vibration suppression (AVS) is a control method for flexible structures. The first step is an accurate, infinite dimension, transfer function (TF), from actuation to measurement. This leads to the collocated, rate feedback AVS controller that in some cases completely eliminates the vibration. In case of the 1D wave equation, the TF consists of pure time delays and low order rational terms, and the AVS controller is rational. In all other cases, the TF and consequently the controller are fractional order in both the delays and the "rational parts". The paper considers stability, performance and actual implementation in such cases.

  2. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  3. Linear ultrasonic motor for absolute gravimeter.

    Science.gov (United States)

    Jian, Yue; Yao, Zhiyuan; Silberschmidt, Vadim V

    2017-05-01

    Thanks to their compactness and suitability for vacuum applications, linear ultrasonic motors are considered as substitutes for classical electromagnetic motors as driving elements in absolute gravimeters. Still, their application is prevented by relatively low power output. To overcome this limitation and provide better stability, a V-type linear ultrasonic motor with a new clamping method is proposed for a gravimeter. In this paper, a mechanical model of stators with flexible clamping components is suggested, according to a design criterion for clamps of linear ultrasonic motors. After that, an effect of tangential and normal rigidity of the clamping components on mechanical output is studied. It is followed by discussion of a new clamping method with sufficient tangential rigidity and a capability to facilitate pre-load. Additionally, a prototype of the motor with the proposed clamping method was fabricated and the performance tests in vertical direction were implemented. Experimental results show that the suggested motor has structural stability and high dynamic performance, such as no-load speed of 1.4m/s and maximal thrust of 43N, meeting the requirements for absolute gravimeters. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Relational versus absolute representation in categorization.

    Science.gov (United States)

    Edwards, Darren J; Pothos, Emmanuel M; Perlman, Amotz

    2012-01-01

    This study explores relational-like and absolute-like representations in categorization. Although there is much evidence that categorization processes can involve information about both the particular physical properties of studied instances and abstract (relational) properties, there has been little work on the factors that lead to one kind of representation as opposed to the other. We tested 370 participants in 6 experiments, in which participants had to classify new items into predefined artificial categories. In 4 experiments, we observed a predominantly relational-like mode of classification, and in 2 experiments we observed a shift toward an absolute-like mode of classification. These results suggest 3 factors that promote a relational-like mode of classification: fewer items per group, more training groups, and the presence of a time delay. Overall, we propose that less information about the distributional properties of a category or weaker memory traces for the category exemplars (induced, e.g., by having smaller categories or a time delay) can encourage relational-like categorization.

  5. On the absolute meaning of motion

    Directory of Open Access Journals (Sweden)

    H. Edwards

    Full Text Available The present manuscript aims to clarify why motion causes matter to age slower in a comparable sense, and how this relates to relativistic effects caused by motion. A fresh analysis of motion, build on first axiom, delivers proof with its result, from which significant new understanding and computational power is gained.A review of experimental results demonstrates, that unaccelerated motion causes matter to age slower in a comparable, observer independent sense. Whilst focusing on this absolute effect, the present manuscript clarifies its context to relativistic effects, detailing their relationship and incorporating both into one consistent picture. The presented theoretical results make new predictions and are testable through suggested experiment of a novel nature. The manuscript finally arrives at an experimental tool and methodology, which as far as motion in ungravitated space is concerned or gravity appreciated, enables us to find the absolute observer independent picture of reality, which is reflected in the comparable display of atomic clocks.The discussion of the theoretical results, derives a physical causal understanding of gravity, a mathematical formulation of which, will be presented. Keywords: Kinematics, Gravity, Atomic clocks, Cosmic microwave background

  6. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  7. Absolute determination of the deuterium content of heavy water, measurement of absolute density

    International Nuclear Information System (INIS)

    Ceccaldi, M.; Riedinger, M.; Menache, M.

    1975-01-01

    The absolute density of two heavy water samples rich in deuterium (with a grade higher than 99.9%) was determined with the hydrostatic method. The exact isotopic composition of this water (hydrogen and oxygen isotopes) was very carefully studied. A theoretical estimate enabled us to get the absolute density value of isotopically pure D 2 16 O. This value was found to be 1104.750 kg.m -3 at t 68 =22.3 0 C and under the pressure of one atmosphere. (orig.) [de

  8. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    Science.gov (United States)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  9. Sensitivity of digital dental photo CIE L*a*b* analysis compared to spectrophotometer clinical assessments over 6 months.

    Science.gov (United States)

    Sluzker, Ariel; Knösel, Michael; Athanasiou, Athanasios E

    2011-10-01

    To assess the sensitivity of digital dental photo CIE L*a*b* analysis compared to clinical spectrophotometer assessments over 6 months. CIE L*a*b* values for the upper right central incisors of 14 predoctoral dental students subjected to certain color-relevant exclusion criteria were recorded at baseline (T0), after 6 months (T1), and 1 week later (T2), using (Method 1) a spectrophotometer and (Method 2) a method of digital photo analysis. Statistical analysis of color and lightness data between both methods and time points were assessed using the Shapiro-Wilk test, Pearson's correlation coefficient (r), Dahlberg's formula for method error calculation, and paired samples t-tests, adopting a level of significance alpha = 0.05. Between T0 - T1, the spectrophotometer recorded significant changes in lightness (75.51 > 77.75) and color values (a*: 3.25 > 2.38; b*: 18.47 > 17.31), whereas significant changes with Method 2 were only seen for b* (21.51 > 20.57). No significant changes for overall color and lightness changes deltaE to deltaE2 were found for either of the methods. The error of the method (T1-T2) and corresponding correlation coefficients r for values L*a*b* were found to be 1.44 / 0.43 / 0.62 (r: 0.69; P = 0.007/0.64; P = 0.14/0.9; P < 0.001) for Method 1 and 0.97/0.67/1.25 (r : 0.87; P < 0.001/0.63; P = 0.17/0.57, P = 0.04) for Method 2, respectively.

  10. Interexaminer reliability in clinical measurement of L*C*h* values of anterior teeth using a spectrophotometer.

    Science.gov (United States)

    Hassel, Alexander J; Grossmann, Anne-christiane; Schmitter, Marc; Balke, Zibandeh; Buzello, Anja M

    2007-01-01

    The objective of this study was to investigate interexaminer reliability in the clinical measurement of the L*C*h* (lightness/value, chroma, hue) values of anterior teeth using a spectrophotometer (Vita Easyshade). The basic color of the maxillary right central incisors and canines of 23 subjects was spectrophotometrically determined by 4 clinicians and an experienced user (development manager) of the spectrophotometer. Also, to analyze the effect of different training with the instrument on interexaminer reliability, 2 of the clinicians were instructed in the use of the spectrophotometer by the experienced examiner, whereas the others instructed themselves by studying the operating manual. Agreement between all examiners was acceptable to excellent (intraclass coefficient > 0.4). The mean value of the measured differences for the central incisors of all subjects for L* values was 5 (for C* = 3.8, h* = 2.7 degrees) and for canines, the mean L* was 4.5 (C* = 3, h* = 1.6 degrees). Results from comparison of the 2 different training methods were inconsistent. Agreement with the experienced examiner ranged from not acceptable (C* values for incisors of self-instructed examiners) to excellent. The distribution of the measurements of 1 subject could lead to deviations in color, probably with clinical impact. For canines, the measurements were at least equally reproducible (in some cases significantly more reproducible) compared to central incisors. Because of the small number of examiners and the inconsistent results, it was not possible to reach a definite conclusion about the effect of different training methods on interexaminer reliability.

  11. Assessing the engagement, learning, and overall experience of students operating an atomic absorption spectrophotometer with remote access technology.

    Science.gov (United States)

    Erasmus, Daniel J; Brewer, Sharon E; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of engagement, learning, and overall experience. Feedback from students suggests that the use of remote access technology is effective in teaching students the principles of chemical analysis by atomic absorption spectroscopy. © 2014 The International Union of Biochemistry and Molecular Biology.

  12. Invariant and Absolute Invariant Means of Double Sequences

    Directory of Open Access Journals (Sweden)

    Abdullah Alotaibi

    2012-01-01

    Full Text Available We examine some properties of the invariant mean, define the concepts of strong σ-convergence and absolute σ-convergence for double sequences, and determine the associated sublinear functionals. We also define the absolute invariant mean through which the space of absolutely σ-convergent double sequences is characterized.

  13. How is an absolute democracy possible?

    Directory of Open Access Journals (Sweden)

    Joanna Bednarek

    2011-01-01

    Full Text Available In the last part of the Empire trilogy, Commonwealth, Negri and Hardt ask about the possibility of the self-governance of the multitude. When answering, they argue that absolute democracy, understood as the political articulation of the multitude that does not entail its unification (construction of the people is possible. As Negri states, this way of thinking about political articulation is rooted in the tradition of democratic materialism and constitutes the alternative to the dominant current of modern political philosophy that identifies political power with sovereignty. The multitude organizes itself politically by means of the constitutive power, identical with the ontological creativity or productivity of the multitude. To state the problem of political organization means to state the problem of class composition: political democracy is at the same time economic democracy.

  14. Absolute partial photoionization cross sections of ethylene

    Science.gov (United States)

    Grimm, F. A.; Whitley, T. A.; Keller, P. R.; Taylor, J. W.

    1991-07-01

    Absolute partial photoionization cross sections for ionization out of the first four valence orbitals to the X 2B 3u, A 2B 3g, B 2A g and C 2B 2u states of the C 2H 4+ ion are presented as a function of photon energy over the energy range from 12 to 26 eV. The experimental results have been compared to previously published relative partial cross sections for the first two bands at 18, 21 and 24 eV. Comparison of the experimental data with continuum multiple scattering Xα calculations provides evidence for extensive autoionization to the X 2B 3u state and confirms the predicted shape resonances in ionization to the A 2B 3g and B 2A g states. Identification of possible transitions for the autoionizing resonances have been made using multiple scattering transition state calculations on Rydberg excited states.

  15. Absolute beam current monitoring in endstation c

    International Nuclear Information System (INIS)

    Bochna, C.

    1995-01-01

    The first few experiments at CEBAF require approximately 1% absolute measurements of beam currents expected to range from 10-25μA. This represents errors of 100-250 nA. The initial complement of beam current monitors are of the non intercepting type. CEBAF accelerator division has provided a stripline monitor and a cavity monitor, and the authors have installed an Unser monitor (parametric current transformer or PCT). After calibrating the Unser monitor with a precision current reference, the authors plan to transfer this calibration using CW beam to the stripline monitors and cavity monitors. It is important that this be done fairly rapidly because while the gain of the Unser monitor is quite stable, the offset may drift on the order of .5μA per hour. A summary of what the authors have learned about the linearity, zero drift, and gain drift of each type of current monitor will be presented

  16. Absolute negative mobility in the anomalous diffusion

    Science.gov (United States)

    Chen, Ruyin; Chen, Chongyang; Nie, Linru

    2017-12-01

    Transport of an inertial Brownian particle driven by the multiplicative Lévy noise was investigated here. Numerical results indicate that: (i) The Lévy noise is able to induce absolute negative mobility (ANM) in the system, while disappearing in the deterministic case; (ii) the ANM can occur in the region of superdiffusion while disappearing in the region of normal diffusion, and the appropriate stable index of the Lévy noise makes the particle move along the opposite direction of the bias force to the maximum degree; (iii) symmetry breaking of the Lévy noise also causes the ANM effect. In addition, the intrinsic physical mechanism and conditions for the ANM to occur are discussed in detail. Our results have the implication that the Lévy noise plays an important role in the occurrence of the ANM phenomenon.

  17. Absolute GPS Positioning Using Genetic Algorithms

    Science.gov (United States)

    Ramillien, G.

    A new inverse approach for restoring the absolute coordinates of a ground -based station from three or four observed GPS pseudo-ranges is proposed. This stochastic method is based on simulations of natural evolution named genetic algorithms (GA). These iterative procedures provide fairly good and robust estimates of the absolute positions in the Earth's geocentric reference system. For comparison/validation, GA results are compared to the ones obtained using the classical linearized least-square scheme for the determination of the XYZ location proposed by Bancroft (1985) which is strongly limited by the number of available observations (i.e. here, the number of input pseudo-ranges must be four). The r.m.s. accuracy of the non -linear cost function reached by this latter method is typically ~10-4 m2 corresponding to ~300-500-m accuracies for each geocentric coordinate. However, GA can provide more acceptable solutions (r.m.s. errors < 10-5 m2), even when only three instantaneous pseudo-ranges are used, such as a lost of lock during a GPS survey. Tuned GA parameters used in different simulations are N=1000 starting individuals, as well as Pc=60-70% and Pm=30-40% for the crossover probability and mutation rate, respectively. Statistical tests on the ability of GA to recover acceptable coordinates in presence of important levels of noise are made simulating nearly 3000 random samples of erroneous pseudo-ranges. Here, two main sources of measurement errors are considered in the inversion: (1) typical satellite-clock errors and/or 300-metre variance atmospheric delays, and (2) Geometrical Dilution of Precision (GDOP) due to the particular GPS satellite configuration at the time of acquisition. Extracting valuable information and even from low-quality starting range observations, GA offer an interesting alternative for high -precision GPS positioning.

  18. Cross-validity of a portable glucose capillary monitors in relation to enzymatic spectrophotometer methods

    Directory of Open Access Journals (Sweden)

    William Alves Lima

    2006-09-01

    Full Text Available The glucose is an important substrate utilizaded during exercise. Accurate measurement of glucose is vital to obtain trustworthy results. The enzymatic spectrophotometer methods are generally considered the “goldstandard” laboratory procedure for measuring of glucose (GEnz, is time consuming, costly, and inappropriate for large scale field testing. Compact and portable glucose monitors (GAccu are quick and easy methods to assess glucose on large numbers of subjects. So, this study aimed to test the cross-validity of GAccu. The sample was composed of 107 men (aged= 35.4±10.7 years; stature= 168.4±6.9 cm; body mass= 73.4±11.2 kg; %fat= 20.9±8.3% – by dual energy x-ray absorptiometry. Blood for measuring fasting glucose was taken in basilar vein (Genz, Bioplus: Bio-2000 and in ring finger (GAccu: Accu-Chek© Advantage©, after a 12-hour overnight fast. GEnz was used as the criterion for cross-validity. Paired t-test shown differences (p RESUMO A glicose é um substrato importante utilizado durante o exercício físico. Medidas acuradas da glicose são fundamentais para a obtenção de resultados confiáveis. O método laboratorial de espectrofotometria enzimática geralmente é considerado o procedimento “padrão ouro” para medir a glicose (GEnz, o qual requer tempo, custo e é inapropriado para o uso em larga escala. Monitores portáteis de glicose (GAccu são rápidos e fáceis para medir a glicose em um grande número de sujeitos. Então, este estudo teve por objetivo testar a validade concorrente do GAccu. A amostra foi composta por 107 homens (idade= 35,4±10,7 anos; estatura= 168,4±6,9 cm; massa corporal= 73,4±11,2 kg; %gordura= 20,9±8,3% – por absortometria de raio-x de dupla energia. O sangue para mensurar a glicose em jejum foi tirado na veia basilar (Genz, Bioplus: Bio-2000 e no dedo anular (GAccu - Accu- Chek© Advantage©, depois de 12h de jejum noturno. O GEnz foi usado como critério para testar a validade

  19. Variance computations for functional of absolute risk estimates.

    Science.gov (United States)

    Pfeiffer, R M; Petracci, E

    2011-07-01

    We present a simple influence function based approach to compute the variances of estimates of absolute risk and functions of absolute risk. We apply this approach to criteria that assess the impact of changes in the risk factor distribution on absolute risk for an individual and at the population level. As an illustration we use an absolute risk prediction model for breast cancer that includes modifiable risk factors in addition to standard breast cancer risk factors. Influence function based variance estimates for absolute risk and the criteria are compared to bootstrap variance estimates.

  20. An in vitro comparison of quantitative light-induced fluorescence-digital and spectrophotometer on monitoring artificial white spot lesions.

    Science.gov (United States)

    Kim, Hee Eun; Kim, Baek-Il

    2015-09-01

    The aim of this study was to evaluate the efficacy of quantitative light-induced fluorescence-digital (QLF-D) compared to a spectrophotometer in monitoring progression of enamel lesions. To generate artificial caries with various severities of lesion depths, twenty bovine specimens were immersed in demineralizing solution for 40 days. During the production of the lesions, repeat measurements of fluorescence loss (ΔF) and color change (ΔE) were performed in six distinct stages after the demineralization of the specimens: after 3, 5, 10, 20, 30, and 40 days of exposure to the demineralizing solution. Changes in the ΔF values in the lesions were analyzed using the QLF-D, and changes in the ΔE values in lesions were analyzed using a spectrophotometer. The repeated measures ANOVA of ΔF and ΔE values were used to determine whether there are significant differences at different exposure times in the demineralizing solution. Spearman's rank correlation coefficient was analyzed between ΔF and ΔE. The ΔF values significantly decreased based on the demineralizing period (pmonitoring color changes. Our findings demonstrate that QLF-D are a more efficient and stable tool for early caries detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Absolute Lower Bound on the Bounce Action

    Science.gov (United States)

    Sato, Ryosuke; Takimoto, Masahiro

    2018-03-01

    The decay rate of a false vacuum is determined by the minimal action solution of the tunneling field: bounce. In this Letter, we focus on models with scalar fields which have a canonical kinetic term in N (>2 ) dimensional Euclidean space, and derive an absolute lower bound on the bounce action. In the case of four-dimensional space, we show the bounce action is generically larger than 24 /λcr, where λcr≡max [-4 V (ϕ )/|ϕ |4] with the false vacuum being at ϕ =0 and V (0 )=0 . We derive this bound on the bounce action without solving the equation of motion explicitly. Our bound is derived by a quite simple discussion, and it provides useful information even if it is difficult to obtain the explicit form of the bounce solution. Our bound offers a sufficient condition for the stability of a false vacuum, and it is useful as a quick check on the vacuum stability for given models. Our bound can be applied to a broad class of scalar potential with any number of scalar fields. We also discuss a necessary condition for the bounce action taking a value close to this lower bound.

  2. Gyrokinetic statistical absolute equilibrium and turbulence

    International Nuclear Information System (INIS)

    Zhu Jianzhou; Hammett, Gregory W.

    2010-01-01

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: a finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N+1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  3. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    International Nuclear Information System (INIS)

    Zhu, Jian-Zhou; Hammett, Gregory W.

    2011-01-01

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence (T.-D. Lee, 'On some statistical properties of hydrodynamical and magnetohydrodynamical fields,' Q. Appl. Math. 10, 69 (1952)) is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  4. Measurement of the 235 U absolute activity

    International Nuclear Information System (INIS)

    Bueno, C.C.; Santos, M.D.S.

    1993-01-01

    The absolute activity of 235 U contained in a sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles emitted simultaneously with the 143 KeV gamma radiations from the 231 Th (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a 1'x 1 1/2 Nal (TI) scintillation detector. The value obtained for the half-life of 235 U, (7.04+-0.01)10 8 y, was compared with the data available from various observers with used different experimental techniques. It is shown that our results are in excellent agreement with the best data available on the subject. (author) 15 refs, 5 figs, 1 tab

  5. Auditory processing in absolute pitch possessors

    Science.gov (United States)

    McKetton, Larissa; Schneider, Keith A.

    2018-05-01

    Absolute pitch (AP) is a rare ability in classifying a musical pitch without a reference standard. It has been of great interest to researchers studying auditory processing and music cognition since it is seldom expressed and sheds light on influences pertaining to neurodevelopmental biological predispositions and the onset of musical training. We investigated the smallest frequency that could be detected or just noticeable difference (JND) between two pitches. Here, we report significant differences in JND thresholds in AP musicians and non-AP musicians compared to non-musician control groups at both 1000 Hz and 987.76 Hz testing frequencies. Although the AP-musicians did better than non-AP musicians, the difference was not significant. In addition, we looked at neuro-anatomical correlates of musicianship and AP using structural MRI. We report increased cortical thickness of the left Heschl's Gyrus (HG) and decreased cortical thickness of the inferior frontal opercular gyrus (IFO) and circular insular sulcus volume (CIS) in AP compared to non-AP musicians and controls. These structures may therefore be optimally enhanced and reduced to form the most efficient network for AP to emerge.

  6. [Tobacco and plastic surgery: An absolute contraindication?

    Science.gov (United States)

    Matusiak, C; De Runz, A; Maschino, H; Brix, M; Simon, E; Claudot, F

    2017-08-01

    Smoking increases perioperative risk regarding wound healing, infection rate and failure of microsurgical procedures. There is no present consensus about plastic and aesthetic surgical indications concerning smoking patients. The aim of our study is to analyze French plastic surgeons practices concerning smokers. A questionnaire was send by e-mail to French plastic surgeons in order to evaluate their own operative indications: patient information about smoking dangers, pre- and postoperative delay of smoking cessation, type of intervention carried out, smoking cessation supports, use of screening test and smoking limit associated to surgery refusing were studied. Statistical tests were used to compare results according to practitioner activity (liberal or public), own smoking habits and time of installation. In 148 questionnaires, only one surgeon did not explain smoking risk. Of the surgeons, 49.3% proposed smoking-cessation supports, more frequently with public practice (P=0.019). In total, 85.4% of surgeons did not use screening tests. Years of installation affected operative indication with smoking patients (P=0.02). Pre- and postoperative smoking cessation delay were on average respectively 4 and 3 weeks in accordance with literature. Potential improvements could be proposed to smoking patients' care: smoking cessation assistance, screening tests, absolute contraindication of some procedures or level of consumption to determine. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen dye.

    Science.gov (United States)

    Moreno, Luis A; Cox, Kendra L

    2010-11-05

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows

  8. Evaluation of the absolute regional temperature potential

    Directory of Open Access Journals (Sweden)

    D. T. Shindell

    2012-09-01

    Full Text Available The Absolute Regional Temperature Potential (ARTP is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90–28° S, 28° S–28° N, 28–60° N and 60–90° N as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within ±20% of the actual responses, though there are some exceptions for 90–28° S and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the ±20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39–45% and 9–39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  9. Orion Absolute Navigation System Progress and Challenge

    Science.gov (United States)

    Holt, Greg N.; D'Souza, Christopher

    2012-01-01

    The absolute navigation design of NASA's Orion vehicle is described. It has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary onboard measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudo-range and delta-range, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, and cold start are discussed as are strategies for whole and partial state updates as well as covariance considerations. Strategies are given for dealing with latent measurements and high-rate propagation using multi-rate architecture. The details of the rate groups and the data ow between the elements is discussed and evaluated.

  10. Planck absolute entropy of a rotating BTZ black hole

    Science.gov (United States)

    Riaz, S. M. Jawwad

    2018-04-01

    In this paper, the Planck absolute entropy and the Bekenstein-Smarr formula of the rotating Banados-Teitelboim-Zanelli (BTZ) black hole are presented via a complex thermodynamical system contributed by its inner and outer horizons. The redefined entropy approaches zero as the temperature of the rotating BTZ black hole tends to absolute zero, satisfying the Nernst formulation of a black hole. Hence, it can be regarded as the Planck absolute entropy of the rotating BTZ black hole.

  11. Positioning, alignment and absolute pointing of the ANTARES neutrino telescope

    International Nuclear Information System (INIS)

    Fehr, F; Distefano, C

    2010-01-01

    A precise detector alignment and absolute pointing is crucial for point-source searches. The ANTARES neutrino telescope utilises an array of hydrophones, tiltmeters and compasses for the relative positioning of the optical sensors. The absolute calibration is accomplished by long-baseline low-frequency triangulation of the acoustic reference devices in the deep-sea with a differential GPS system at the sea surface. The absolute pointing can be independently verified by detecting the shadow of the Moon in cosmic rays.

  12. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Total ozone derived from UV spectrophotometer measurements on the NASA CV-990 aircraft for the fall 1976 latitude survey flights

    Science.gov (United States)

    Hanser, F. A.

    1977-01-01

    An ultraviolet interference filter spectrophotometer was modified to use a photodiode and was flown on latitude survey flights in the fall of 1976. Comparison with Dobson station total ozone values shows agreement between UVS and Dobson total ozone of + or - 2 percent. The procedure used to convert UVS measured ozone above the aircraft altitude to total ozone above ground level introduces an additional 2 percent deviation for very high altitude UVS ozone data. Under stable aircraft operating conditions, the UVS derived ozone values have a variability, or reproducibility, of better than + or -1 percent. The UVS data from the latitude survey flights yield a detailed latitude profile of total ozone over the Pacific Ocean during November 1976. Significant latitudinal structure in total ozone is found at the middle latitudes (30 deg to 40 deg N and S).

  14. Signal-to-noise optimization and evaluation of a home-made visible diode-array spectrophotometer

    Science.gov (United States)

    Raimundo, Jr., Ivo M.; Pasquini, Celio

    1993-01-01

    This paper describes a simple low-cost multichannel visible spectrophotometer built with an RL512G EGG-Reticon photodiode array. A symmetric Czerny-Turner optical design was employed; instrument control was via a single-board microcomputer based on the 8085 Intel microprocessor. Spectral intensity data are stored in the single-board's RAM and then transferred to an IBM-AT 3865X compatible microcomputer through a RS-232C interface. This external microcomputer processes the data to recover transmittance, absorbance or relative intensity of the spectra. The signal-to-noise ratio and dynamic range were improved by using variable integration times, which increase during the same scan; and by the use of either weighted or unweighted sliding average of consecutive diodes. The instrument is suitable for automatic methods requiring quasi-simultaneous multiwavelength detections, such as multivariative calibration and flow-injection gradient scan techniques. PMID:18924979

  15. A New High-sensitivity solar X-ray Spectrophotometer SphinX:early operations and databases

    Science.gov (United States)

    Gburek, Szymon; Sylwester, Janusz; Kowalinski, Miroslaw; Siarkowski, Marek; Bakala, Jaroslaw; Podgorski, Piotr; Trzebinski, Witold; Plocieniak, Stefan; Kordylewski, Zbigniew; Kuzin, Sergey; Farnik, Frantisek; Reale, Fabio

    The Solar Photometer in X-rays (SphinX) is an instrument operating aboard Russian CORONAS-Photon satellite. A short description of this unique instrument will be presented and its unique capabilities discussed. SphinX is presently the most sensitive solar X-ray spectrophotometer measuring solar spectra in the energy range above 1 keV. A large archive of SphinX mea-surements has already been collected. General access to these measurements is possible. The SphinX data repositories contain lightcurves, spectra, and photon arrival time measurements. The SphinX data cover nearly continuously the period since the satellite launch on January 30, 2009 up to the end-of November 2009. Present instrument status, data formats and data access methods will be shown. An overview of possible new science coming from SphinX data analysis will be discussed.

  16. Use of Fourier transformed infrared spectrophotometer (FTIR) for determination of breastmilk output by the deuterium dilution method among Senegalese women

    International Nuclear Information System (INIS)

    Sarr Cisse, Aita; Diaham, Babou; Dossou, Nicole; Guiro, Amadou Tidiane; Wade, Salimata; Bluck, Leslie

    2002-01-01

    Breastmilk output can be estimated from the mother's total body water and water turnover rates after oral administration of deuterium oxide. Usually the deuterium enrichments are determined using a isotope ratio mass spectrometer, which is expensive and requires a specialist for operation and maintenance. Such equipment is dfficult to set up in developing countries. A less expensive method was developed which uses a Fourier transform infrared spectrophotometer (FTIR) for deuterium enrichment analysis. This study evaluated the constraints of using FTIR to study lactating women in Senegal. The deuterium isotope method was found to be adequate for free living subjects and presented few constraints except for the duration of the saliva sampling (14 days). The method offers the opportunity to determine simultaneously breastmilk output, mother's body composition, and breastfeeding practices. Deuterium sample enrichments measured with FTIR were fast and easy, but for spectrum quality some environmental control is required to optimize the results. (Authors)

  17. infrared spectrophotometer for simultaneous detection of traces of heavy water and indocyanine green in flowing blood. In vivo experimentation

    International Nuclear Information System (INIS)

    Capitini, R.; Roveyaz, P.

    1981-07-01

    We have developed an infrared absorption method for the pulmonary extravascular water and cardiac output determination by the multiple indicator technique. This led us to construct an original double differential spectrophotometer (DUPLEX) for simultaneous detection of traces of heavy water (D 2 O) and indocyanine green (ICG) in circulating blood in a single absorption cell. This DUPLEX is connected to a computer and results are treated on line. D 2 O and ICG are used as non toxic diffusible and vascular tracers respectively. Performances of the DUPLEX are given and show a high accuracy with D 2 O (x 10) and ICG (x 2) compared with the commercial optical analysers. We show the validity of the method for determining the cardiac output and the pulmonary extravascular water in the course of numerous experiments on human and rats subjects. Preliminary results concerning the measurement of global water on rats are also given [fr

  18. Method for improving the use of PASCO brand spectrophotometer using DataStudio program applied to radiometric surveys for LAFTLA

    International Nuclear Information System (INIS)

    Bolanos Rodriguez, Gary

    2008-01-01

    Escuela de Ingenieria Electrica at the Universidad de Costa Rica has developed a procedure for the improved use of a PASCO brand Spectrophotometer of the Laboratorio de Fotonica y Tecnologia Laser Aplicada. The program has used DataStudio for the application in radiometric surveys in LAFTLA. Important conclusions have been obtained by the assembly of optical experiments, software and data collection and analysis, such as the behavior of a emitting source radiation known as black body and its relation to the temperature, wavelength and intensity of light. The user guide has been detailed exposing calibrations of the sensors, the definition of constants needed for obtaining parameters and assembly and commissioning of the equipment. (author) [es

  19. Concentration determination of nucleic acids and proteins using the micro-volume BioSpec-nano-spectrophotometer.

    Science.gov (United States)

    Sukumaran, Suja

    2011-02-17

    Nucleic acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected. Protein concentration results can be expressed as μg/mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells.

  20. Analysis of Shade Matching in Natural Dentitions Using Intraoral Digital Spectrophotometer in LED and Filtered LED Light Sources.

    Science.gov (United States)

    Chitrarsu, Vijai Krishnan; Chidambaranathan, Ahila Singaravel; Balasubramaniam, Muthukumar

    2017-10-31

    To evaluate the shade matching capabilities in natural dentitions using Vita Toothguide 3D-Master and an intraoral digital spectrophotometer (Vita Easyshade Advance 4.0) in various light sources. Participants between 20 and 40 years old with natural, unrestored right maxillary central incisors, no history of bleaching, orthodontic treatment, or malocclusion and no rotations were included. According to their shades, subjects were randomly selected and grouped into A1, A2, and A3. A total of 100 participants (50 male and 50 female) in each group were chosen for this study. Shade selection was made between 10 am and 2 pm for all light sources. The same examiner selected the shade of natural teeth with Vita Toothguide 3D-Master under natural light within 2 minutes. Once the Vita Toothguide 3D-Masterwas matched with the maxillary right central incisor, the L*, a*, and b* values, chroma, and hue were recorded with Vita Easyshade Advance 4.0 by placing it on the shade tab under the same light source. The values were statistically analyzed using one-way ANOVA and Tukey's HSD post hoc test with SPSS v22.0 software. The mean ∆E* ab values for shades A1, A2, and A3 for groups 1, 2, and 3 were statistically significantly different from each other (p spectrophotometer showed statistically significant differences in shade matching compared to Vita Toothguide 3D-Master. Incandescent light showed more accurate shade matching than the filtered LED, LED, and daylight. © 2017 by the American College of Prosthodontists.

  1. Spectrophotometer is useful for assessing vitiligo and chemical leukoderma severity by quantifying color difference with surrounding normally pigmented skin.

    Science.gov (United States)

    Hayashi, M; Okamura, K; Araki, Y; Suzuki, M; Tanaka, T; Abe, Y; Nakano, S; Yoshizawa, J; Hozumi, Y; Inoie, M; Suzuki, T

    2018-05-01

    Acquired skin hypopigmentation has many etiologies, including autoimmune melanocyte destruction, skin aging, inflammation, and chemical exposure. Distinguishing lesions from normally pigmented skin is clinically important to precisely assess disease severity. However, no gold standard assessment method has been reported. We aimed to investigate whether spectrophotometers are useful for assessing vitiligo and rhododendrol (4-(4-hydroxyphenol)-2-butanol) (Rhododenol ® )-induced leukoderma disease severity by quantifying skin color. Mexameter ® MX18 and CM-700d spectrophotometer were used for assessing vitiligo/leukoderma by measuring melanin index, L*a*b* color space, and ΔE*ab value, which represents the color difference between two subjects and is calculated by the values of L*a*b*. MX18 and CM-700d can quantitatively distinguish vitiligo/leukoderma from normally pigmented skin based on melanin index. CM-700d consistently quantified the color of vitiligo/leukoderma lesions and surrounding normally pigmented skin in L*a*b* color spaces and ΔE*ab. ΔE*ab is well correlated with melanin index and clinical appearance. ΔE*ab has been frequently used in aesthetic dentistry; however, current study is the first to use it in the measurement of skin color. ΔE*ab seems to be a useful parameter to evaluate the color contrast between vitiligo/leukoderma and surrounding normally pigmented skin and can be used to evaluate disease severity and patient's quality of life. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Concentration Determination of Nucleic Acids and Proteins Using the Micro-volume Bio-spec Nano Spectrophotometer

    Science.gov (United States)

    Sukumaran, Suja

    2011-01-01

    Nucleic Acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected1. Protein concentration results can be expressed as μg/ mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells. PMID:21372788

  3. Absolute chronology and stratigraphy of Lepenski Vir

    Directory of Open Access Journals (Sweden)

    Borić Dušan

    2007-01-01

    Full Text Available In the last decade, a number of specialist analyses were made on the material from old excavations of Mesolithic-Neolithic sites in the Danube Gorges. These new results altered significantly our understanding of the Lepenski Vir culture. The question of chronology of this regional phenomenon has been acute since the discovery of Lepenski Vir in the 1960s, and it remains of key importance for understanding the character of Mesolithic-Neolithic transformations in this and the neighbouring regions. The most heated debate was fuelled by the initial stratigraphic and chronological attribution of the type-site itself. There remained the question about the adequate dating of the most prominent phase at this site characterized by buildings with trapezoidal bases covered with limestone floors and with rectangular stone-lined hearths placed in the centre of these features. There have been suggestions that these features also contain Early Neolithic Starčevo type pottery and other similar items of material culture and should thus be dated to the Early Neolithic historical context. Moreover, the first series of conventional radiocarbon determinations (21 dates also suggested that the absolute chronology of these features should be confined to the period from around 6400-5500 cal BC (Fig. 1. Due to the importance of defining more precisely the chronology for the start of construction of these particular features at Lepenski Vir and for establishing the life-span of these buildings and their associated material culture, we have AMS (Accelerator Mass Spectrometry dated a number of contexts from this site. The results are presented in this paper. The project was made possible through the Oxford Radiocarbon Accelerate Dating Service (ORADS programme funded by the Arts and Humanities Research Council (AHRC and the Natural Environment Research Council (NERC of the Great Britain. Apart from those dates presented in this paper, there are 29 previously published

  4. Measurements in interplanetary space and in the Martian upper atmosphere with a hydrogen absorption-cell spectrophotometer for Lα-radiation on-board Mars 4 - 7 spaceprobes

    International Nuclear Information System (INIS)

    Babichenko, S.I.; Deregusov, E.V.; Kurt, V.G.; Romanova, N.N.; Skljankin, V.A.; Smirnov, A.S.; Bertaux, J.J.; Blamont, J.

    1977-01-01

    An ultraviolet spectrophotometer UFS-2, designed to measure radiation of atomic hydrogen in the Lα-line, was installed onboard the interplanetary Mars 4 - 7 spaceprobes launched in August 1973. The absorption cell which was used for the first time outside the hydrogen geocorona allowed direct temperature measurements of neutral interstellar hydrogen near the Sun and in the upper Martian atmosphere. (Auth.)

  5. X-ray spectrophotometer SphinX and particle spectrometer STEP-F of the satellite experiment CORONAS-PHOTON. Preliminary results of the joint data analysis

    Science.gov (United States)

    Dudnik, O. V.; Podgorski, P.; Sylwester, J.; Gburek, S.; Kowalinski, M.; Siarkowski, M.; Plocieniak, S.; Bakala, J.

    2012-04-01

    A joint analysis is carried out of data obtained with the help of the solar X-ray SphinX spectrophotometer and the electron and proton satellite telescope STEP-F in May 2009 in the course of the scientific space experiment CORONAS-PHOTON. In order to determine the energies and particle types, in the analysis of spectrophotometer records data are used on the intensities of electrons, protons, and secondary γ-radiation, obtained by the STEP-F telescope, which was located in close proximity to the SphinX spectrophotometer. The identical reaction of both instruments is noted at the intersection of regions of the Brazilian magnetic anomaly and the Earth's radiation belts. It is shown that large area photodiodes, serving as sensors of the X-ray spectrometer, reliably record electron fluxes of low and intermediate energies, as well as fluxes of the secondary gamma radiation from construction materials of detector modules, the TESIS instrument complex, and the spacecraft itself. The dynamics of electron fluxes, recorded by the SphinX spectrophotometer in the vicinity of a weak geomagnetic storm, supplements the information about the processes of radial diffusion of electrons, which was studied using the STEP-F telescope.

  6. Does Absolute Synonymy exist in Owere-Igbo? | Omego | AFRREV ...

    African Journals Online (AJOL)

    Among Igbo linguistic researchers, determining whether absolute synonymy exists in Owere–Igbo, a dialect of the Igbo language predominantly spoken by the people of Owerri, Imo State, Nigeria, has become a thorny issue. While some linguistic scholars strive to establish that absolute synonymy exists in the lexical ...

  7. Absolute tense forms in Tswana | Pretorius | Journal for Language ...

    African Journals Online (AJOL)

    These views were compared in an attempt to put forth an applicable framework for the classification of the tenses in Tswana and to identify the absolute tenses of Tswana. Keywords: tense; simple tenses; compound tenses; absolute tenses; relative tenses; aspect; auxiliary verbs; auxiliary verbal groups; Tswana Opsomming

  8. Absolute calibration of sniffer probes on Wendelstein 7-X

    NARCIS (Netherlands)

    Moseev, D.; Laqua, H.P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.J.; Oosterbeek, J.W.

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of

  9. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  10. A developmental study of latent absolute pitch memory.

    Science.gov (United States)

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  11. Advancing Absolute Calibration for JWST and Other Applications

    Science.gov (United States)

    Rieke, George; Bohlin, Ralph; Boyajian, Tabetha; Carey, Sean; Casagrande, Luca; Deustua, Susana; Gordon, Karl; Kraemer, Kathleen; Marengo, Massimo; Schlawin, Everett; Su, Kate; Sloan, Greg; Volk, Kevin

    2017-10-01

    We propose to exploit the unique optical stability of the Spitzer telescope, along with that of IRAC, to (1) transfer the accurate absolute calibration obtained with MSX on very bright stars directly to two reference stars within the dynamic range of the JWST imagers (and of other modern instrumentation); (2) establish a second accurate absolute calibration based on the absolutely calibrated spectrum of the sun, transferred onto the astronomical system via alpha Cen A; and (3) provide accurate infrared measurements for the 11 (of 15) highest priority stars with no such data but with accurate interferometrically measured diameters, allowing us to optimize determinations of effective temperatures using the infrared flux method and thus to extend the accurate absolute calibration spectrally. This program is integral to plans for an accurate absolute calibration of JWST and will also provide a valuable Spitzer legacy.

  12. Scientific results from the cosmic background explorer (COBE)

    International Nuclear Information System (INIS)

    Bennett, C.L.; Boggess, N.W.; Cheng, E.S.; Hauser, M.G.; Kelsall, T.; Mather, J.C.; Moseley, S.H. Jr.; Shafer, R.A.; Silverberg, R.F.; Murdock, T.L.; Smoot, G.F.; Weiss, R.; Wright, E.L.

    1993-01-01

    The National Aeronautics and Space Administration (NASA) has flown the COBE satellite to observe the Big Bang and the subsequent formation of galaxies and large-scale structure. Data from the Far-Infrared Absolute Spectrophotometer (FIRAS) show that the spectrum of the cosmic microwave background is that of a black body of temperature T = 2.73 ± 0.06 K, with no deviation from a black-body spectrum greater than 0.25% of the peak brightness. The data from the Differential Microwave Radiometers (DMR) show statistically significant cosmic microwave background anisotropy, consistent with a scale-invariant primordial density fluctuation spectrum. Measurements from the Diffuse Infrared Background Experiment (DIRBE) provide new conservation upper limits to the cosmic infrared background. Extensive modeling of solar system and galactic infrared foregrounds is required for further improvement in the cosmic infrared background limits. 104 refs., 1 tab

  13. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  14. Intersstellar absorption lines between 2000 and 3000 A in nearby stars observed with BUSS. [Balloon Borne Ultraviolet Spectrophotometer

    Science.gov (United States)

    De Boer, K. S.; Lenhart, H.; Van Der Hucht, K. A.; Kamperman, T. M.; Kondo, Y.

    1986-01-01

    Spectra obtained between 2000 and 3000 A with the Balloon Borne Ultraviolet Spectrophotometer (BUSS) payload were examined for interstellar absorption lines. In bright stars, with spectral types between O9V and F5V, such lines were measured of Mg I, Mg II, Cr II, Mn II, Fe II and Zn II, with Cr II and Zn II data of especially high quality. Column densities were derived and interstellar abundances were determined for the above species. It was found that metal depletion increases with increasing E(B-V); Fe was most affected and Zn showed a small depletion for E(B-V) greater than 0.3 towards Sco-Oph. The metal column densities, derived for Alpha-And, Kappa-Dra, Alpha-Com, Alpha-Aql, and 29 Cyg were used to infer N(H I). It was shown that the ratio of Mg I to Na I is instrumental in determining the ionization structure along each line of sight. The spectra of Aql stars confirms the presence of large gas densities near Alpha-Oph. Moreover, data indicated that the Rho-Oph N(H I) value needs to be altered to 35 x 10 to the 20th/sq cm, based on observed ion ratios and analysis of the Copernicus L-alpha profile.

  15. Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer.

    Science.gov (United States)

    Kim, Jin-Cheol; Yu, Bin; Lee, Yong-Keun

    2008-12-01

    To determine the changes in color parameters of Vitapan 3D-Master shade guide tabs by a spectrophotometer (SP) or a spectroradiometer (SR), and by the removal of the surface layer of the tabs that was performed to make a flat measuring surface for the SP color measurement. Color of the shade tabs was measured before and after removing the surface layer of the tabs using SP and SR. Correlations between the color parameters between the original (OR) and the surface layer removed (RM) tabs and between the SP and the SR measurements were determined (alpha=0.05). Based on SP, the lightness, chroma, CIE a* and b* values measured after the surface layer removal were higher than those of the original tabs except a few cases. Based on SR, the chroma and CIE a* and b* values measured after surface layer removal were higher than those of the original tabs except a few cases; however, in case of the lightness, the changes varied by the shade designation. Type of instrument influenced the changes in color parameters based on paired t-test (pspectrophotometer or a spectroradiometer, measurement protocols should be specified because color difference by the surface layer removal and the instrument was high.

  16. Direct measurement of the fluorescence characteristics of aquatic humic substances by a three-dimensional fluorescence spectrophotometer

    International Nuclear Information System (INIS)

    Nagao, Seiya; Senoo, Muneaki; Suzuki, Yasuhiro; Nakaguchi, Yuzuru; Hiraki, Keizo.

    1997-01-01

    Humic substances play an important role in the transport of trace metals and insoluble organic materials. They are also considered to be precursors of trihalomethane in aquatic environments. The direct measurement of humic substances was carried out with a three-dimensional fluorescence spectrophotometer after filtering natural-water samples through a GF/F glass fiber filter. Because the influence of the humic concentration, pH and ionic strength on the three-dimensional excitation emission matrix spectra is negligible, the proposed method can be directly applied to the characterization of humic substances in freshwater samples (humic concentration 0.5-10 mg 1 -1 , pH6-9 and ionic strength <0.04 M) and sea-water samples (ionic strength 0.75 M). Humic substances in river, lake and pore water samples exhibit 2-3 peaks at excitation 305-340 nm/emission 415-440 nm and excitation 250-270 nm/emission 440-450 nm. These peak positions correspond to those of fulvic acids isolated from soil. (author)

  17. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  18. Loop system for creating jet fuel vapor standards used in the calibration of infrared spectrophotometers and gas chromatographs.

    Science.gov (United States)

    Reboulet, James; Cunningham, Robert; Gunasekar, Palur G; Chapman, Gail D; Stevens, Sean C

    2009-02-01

    A whole body inhalation study of mixed jet fuel vapor and its aerosol necessitated the development of a method for preparing vapor only standards from the neat fuel. Jet fuel is a complex mixture of components which partitions between aerosol and vapor when aspirated based on relative volatility of the individual compounds. A method was desired which could separate the vapor portion from the aerosol component to prepare standards for the calibration of infrared spectrophotometers and a head space gas chromatography system. A re-circulating loop system was developed which provided vapor only standards whose composition matched those seen in an exposure system. Comparisons of nominal concentrations in the exposure system to those determined by infrared spectrophotometry were in 92-95% agreement. Comparison of jet fuel vapor concentrations determined by infrared spectrophotometry compared to head space gas chromatography yielded a 93% overall agreement in trial runs. These levels of agreement show the loop system to be a viable method for creating jet fuel vapor standards for calibrating instruments.

  19. Efficacy of intrahepatic absolute alcohol in unrespectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Hameed, K.; Khan, I.U.; Shah, S.

    2001-01-01

    To determine efficacy of intrahepatic absolute alcohol injection in researchable hepatocellular carcinoma. A randomized, controlled, experimental and interventional clinical trial. Gastroenterology Department, PGMI, Hayatabad Medical Complex, Peshawar during the period from June, 1998 to June, 2000. Thirty patients were treated by percutaneous, intrahepatic absolute alcohol injection sin repeated sessions, 33 patients were not given or treated with alcohol to serve as control. Both the groups were comparable for age, sex and other baseline characteristics. Absolute alcohol therapy significantly improved quality of life of patients, reduced the tumor size and mortality as well as showed significantly better results regarding survival (P< 0.05) than the patients of control group. We conclude that absolute alcohol is a beneficial and safe palliative treatment measure in advanced hepatocellular carcinoma (HCC). (author)

  20. DOES ABSOLUTE SYNONYMY EXIST IN OWERE-IGBO?

    African Journals Online (AJOL)

    USER

    The researcher also interviewed native speakers of the dialect. The study ... The word 'synonymy' means sameness of meaning, i.e., a relationship in which more ... whether absolute synonymy exists in Owere–Igbo or not. ..... 'close this book'.

  1. Prognostic Value of Absolute versus Relative Rise of Blood ...

    African Journals Online (AJOL)

    maternal outcome than a relative rise in the systolic/diastolic blood pressure from mid pregnancy, which did not reach this absolute level. We conclude that in the Nigerian obstetric population, the practice of diagnosing pregnancy hypertension on ...

  2. Absolute calibration of sniffer probes on Wendelstein 7-X

    International Nuclear Information System (INIS)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-01-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m 2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m 2 per MW injected beam power is measured.

  3. Absolute calibration of sniffer probes on Wendelstein 7-X

    Science.gov (United States)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m2 per MW injected beam power is measured.

  4. Absolute calibration of sniffer probes on Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Moseev, D., E-mail: dmitry.moseev@ipp.mpg.de; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Gellert, F. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Ernst-Moritz-Arndt-Universität Greifswald, Greifswald (Germany); Oosterbeek, J. W. [Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-08-15

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m{sup 2} per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m{sup 2} per MW injected beam power is measured.

  5. Probative value of absolute and relative judgments in eyewitness identification.

    Science.gov (United States)

    Clark, Steven E; Erickson, Michael A; Breneman, Jesse

    2011-10-01

    It is well-accepted that eyewitness identification decisions based on relative judgments are less accurate than identification decisions based on absolute judgments. However, the theoretical foundation for this view has not been established. In this study relative and absolute judgments were compared through simulations of the WITNESS model (Clark, Appl Cogn Psychol 17:629-654, 2003) to address the question: Do suspect identifications based on absolute judgments have higher probative value than suspect identifications based on relative judgments? Simulations of the WITNESS model showed a consistent advantage for absolute judgments over relative judgments for suspect-matched lineups. However, simulations of same-foils lineups showed a complex interaction based on the accuracy of memory and the similarity relationships among lineup members.

  6. Changes in Absolute Sea Level Along U.S. Coasts

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map shows changes in absolute sea level from 1960 to 2016 based on satellite measurements. Data were adjusted by applying an inverted barometer (air pressure)...

  7. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.; Krishnan, Shyam; Stoltz, Brian M.

    2011-01-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional

  8. A proposal to measure absolute environmental sustainability in lifecycle assessment

    DEFF Research Database (Denmark)

    Bjørn, Anders; Margni, Manuele; Roy, Pierre-Olivier

    2016-01-01

    sustainable are therefore increasingly important. Such absolute indicators exist, but suffer from shortcomings such as incomplete coverage of environmental issues, varying data quality and varying or insufficient spatial resolution. The purpose of this article is to demonstrate that life cycle assessment (LCA...... in supporting decisions aimed at simultaneously reducing environmental impacts efficiently and maintaining or achieving environmental sustainability. We have demonstrated that LCA indicators can be modified from being relative to being absolute indicators of environmental sustainability. Further research should...

  9. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    OpenAIRE

    Sammie eTarenskeen; Mirjam eBroersma; Mirjam eBroersma; Bart eGeurts

    2015-01-01

    The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a bet...

  10. Overspecification of color, pattern, and size: salience, absoluteness, and consistency

    OpenAIRE

    Tarenskeen, S.L.; Broersma, M.; Geurts, B.

    2015-01-01

    The rates of overspecification of color, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Color and pattern are absolute and salient attributes, whereas size is relative and less salient. Additionally, a tendency toward consistent responses is assessed. Using a within-participants design, we find similar rates of color and pattern overspecification, which are both higher than the rate of size overspecification. Usi...

  11. The Pragmatics of "Unruly" Dative Absolutes in Early Slavic

    Directory of Open Access Journals (Sweden)

    Daniel E. Collins

    2011-08-01

    Full Text Available This chapter examines some uses of the dative absolute in Old Church Slavonic and in early recensional Slavonic texts that depart from notions of how Indo-European absolute constructions should behave, either because they have subjects coreferential with the (putative main-clause subjects or because they function as if they were main clauses in their own right. Such "noncanonical" absolutes have generally been written off as mechanistic translations or as mistakes by scribes who did not understand the proper uses of the construction. In reality, the problem is not with literalistic translators or incompetent scribes but with the definition of the construction itself; it is quite possible to redefine the Early Slavic dative absolute in a way that accounts for the supposedly deviant cases. While the absolute is generally dependent semantically on an adjacent unit of discourse, it should not always be regarded as subordinated syntactically. There are good grounds for viewing some absolutes not as dependent clauses but as independent sentences whose collateral character is an issue not of syntax but of the pragmatics of discourse.

  12. A new colorimetric DPPH• scavenging activity method with no need for a spectrophotometer applied on synthetic and natural antioxidants and medicinal herbs.

    Science.gov (United States)

    Akar, Zeynep; Küçük, Murat; Doğan, Hacer

    2017-12-01

    2,2-Diphenyl-1-picrylhydrazyl (DPPH • ) radical scavenging, the most commonly used antioxidant method with more than seventeen thousand articles cited, is very practical; however, as with most assays, it has the major disadvantage of dependence on a spectrophotometer. To overcome this drawback, the colorimetric determination of the antioxidant activity using a scanner and freely available Image J software was developed. In this new method, the mixtures of solutions of DPPH • and standard antioxidants or extracts of common medicinal herbs were dropped onto TLC plates, after an incubation period. The spot images were evaluated with Image J software to determine CSC 50 values, the sample concentrations providing 50% colour reduction, which were very similar with the SC 50 values obtained with spectrophotometric method. The advantages of the new method are the use of lower amounts of reagents and solvents, no need for costly spectrophotometers, and thus significantly lowered costs, and convenient implementation in any environment and situation.

  13. Design of a Simple UV Double Beam Spectrophotometer Detector Based on a High Gain Trans Impedance Operational Amplifiers for RNA Measurement

    Directory of Open Access Journals (Sweden)

    Alakhib Ibrahim Abdelbary

    2016-07-01

    Full Text Available In this work a simple double beam spectrophotometer detector for the nucleic acid detection has been designed. The developed system contains photodiodes as a sensor, logarithamatic transimpedance amplifier circuit and filter circuit.The developed prototype design accuracy is validated by running a RNA sample and the result shows that our simplified developed setup detects the present of RNA in the sample.

  14. Auditory working memory predicts individual differences in absolute pitch learning.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Koch, Rachelle; Nusbaum, Howard C

    2015-07-01

    Absolute pitch (AP) is typically defined as the ability to label an isolated tone as a musical note in the absence of a reference tone. At first glance the acquisition of AP note categories seems like a perceptual learning task, since individuals must assign a category label to a stimulus based on a single perceptual dimension (pitch) while ignoring other perceptual dimensions (e.g., loudness, octave, instrument). AP, however, is rarely discussed in terms of domain-general perceptual learning mechanisms. This is because AP is typically assumed to depend on a critical period of development, in which early exposure to pitches and musical labels is thought to be necessary for the development of AP precluding the possibility of adult acquisition of AP. Despite this view of AP, several previous studies have found evidence that absolute pitch category learning is, to an extent, trainable in a post-critical period adult population, even if the performance typically achieved by this population is below the performance of a "true" AP possessor. The current studies attempt to understand the individual differences in learning to categorize notes using absolute pitch cues by testing a specific prediction regarding cognitive capacity related to categorization - to what extent does an individual's general auditory working memory capacity (WMC) predict the success of absolute pitch category acquisition. Since WMC has been shown to predict performance on a wide variety of other perceptual and category learning tasks, we predict that individuals with higher WMC should be better at learning absolute pitch note categories than individuals with lower WMC. Across two studies, we demonstrate that auditory WMC predicts the efficacy of learning absolute pitch note categories. These results suggest that a higher general auditory WMC might underlie the formation of absolute pitch categories for post-critical period adults. Implications for understanding the mechanisms that underlie the

  15. An in-line spectrophotometer on a centrifugal microfluidic platform for real-time protein determination and calibration.

    Science.gov (United States)

    Ding, Zhaoxiong; Zhang, Dongying; Wang, Guanghui; Tang, Minghui; Dong, Yumin; Zhang, Yixin; Ho, Ho-Pui; Zhang, Xuping

    2016-09-21

    In this paper, an in-line, low-cost, miniature and portable spectrophotometric detection system is presented and used for fast protein determination and calibration in centrifugal microfluidics. Our portable detection system is configured with paired emitter and detector diodes (PEDD), where the light beam between both LEDs is collimated with enhanced system tolerance. It is the first time that a physical model of PEDD is clearly presented, which could be modelled as a photosensitive RC oscillator. A portable centrifugal microfluidic system that contains a wireless port in real-time communication with a smartphone has been built to show that PEDD is an effective strategy for conducting rapid protein bioassays with detection performance comparable to that of a UV-vis spectrophotometer. The choice of centrifugal microfluidics offers the unique benefits of highly parallel fluidic actuation at high accuracy while there is no need for a pump, as inertial forces are present within the entire spinning disc and accurately controlled by varying the spinning speed. As a demonstration experiment, we have conducted the Bradford assay for bovine serum albumin (BSA) concentration calibration from 0 to 2 mg mL(-1). Moreover, a novel centrifugal disc with a spiral microchannel is proposed for automatic distribution and metering of the sample to all the parallel reactions at one time. The reported lab-on-a-disc scheme with PEDD detection may offer a solution for high-throughput assays, such as protein density calibration, drug screening and drug solubility measurement that require the handling of a large number of reactions in parallel.

  16. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    Science.gov (United States)

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Relative and absolute risk in epidemiology and health physics

    International Nuclear Information System (INIS)

    Goldsmith, R.; Peterson, H.T. Jr.

    1983-01-01

    The health risk from ionizing radiation commonly is expressed in two forms: (1) the relative risk, which is the percentage increase in natural disease rate and (2) the absolute or attributable risk which represents the difference between the natural rate and the rate associated with the agent in question. Relative risk estimates for ionizing radiation generally are higher than those expressed as the absolute risk. This raises the question of which risk estimator is the most appropriate under different conditions. The absolute risk has generally been used for radiation risk assessment, although mathematical combinations such as the arithmetic or geometric mean of both the absolute and relative risks, have also been used. Combinations of the two risk estimators are not valid because the absolute and relative risk are not independent variables. Both human epidemiologic studies and animal experimental data can be found to illustrate the functional relationship between the natural cancer risk and the risk associated with radiation. This implies that the radiation risk estimate derived from one population may not be appropriate for predictions in another population, unless it is adjusted for the difference in the natural disease incidence between the two populations

  18. Absolute Navigation Information Estimation for Micro Planetary Rovers

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2016-03-01

    Full Text Available This paper provides algorithms to estimate absolute navigation information, e.g., absolute attitude and position, by using low power, weight and volume Microelectromechanical Systems-type (MEMS sensors that are suitable for micro planetary rovers. Planetary rovers appear to be easily navigable robots due to their extreme slow speed and rotation but, unfortunately, the sensor suites available for terrestrial robots are not always available for planetary rover navigation. This makes them difficult to navigate in a completely unexplored, harsh and complex environment. Whereas the relative attitude and position can be tracked in a similar way as for ground robots, absolute navigation information, unlike in terrestrial applications, is difficult to obtain for a remote celestial body, such as Mars or the Moon. In this paper, an algorithm called the EASI algorithm (Estimation of Attitude using Sun sensor and Inclinometer is presented to estimate the absolute attitude using a MEMS-type sun sensor and inclinometer, only. Moreover, the output of the EASI algorithm is fused with MEMS gyros to produce more accurate and reliable attitude estimates. An absolute position estimation algorithm has also been presented based on these on-board sensors. Experimental results demonstrate the viability of the proposed algorithms and the sensor suite for low-cost and low-weight micro planetary rovers.

  19. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  20. Perceiving pitch absolutely: Comparing absolute and relative pitch possessors in a pitch memory task

    Directory of Open Access Journals (Sweden)

    Schlaug Gottfried

    2009-08-01

    Full Text Available Abstract Background The perceptual-cognitive mechanisms and neural correlates of Absolute Pitch (AP are not fully understood. The aim of this fMRI study was to examine the neural network underlying AP using a pitch memory experiment and contrasting two groups of musicians with each other, those that have AP and those that do not. Results We found a common activation pattern for both groups that included the superior temporal gyrus (STG extending into the adjacent superior temporal sulcus (STS, the inferior parietal lobule (IPL extending into the adjacent intraparietal sulcus (IPS, the posterior part of the inferior frontal gyrus (IFG, the pre-supplementary motor area (pre-SMA, and superior lateral cerebellar regions. Significant between-group differences were seen in the left STS during the early encoding phase of the pitch memory task (more activation in AP musicians and in the right superior parietal lobule (SPL/intraparietal sulcus (IPS during the early perceptual phase (ITP 0–3 and later working memory/multimodal encoding phase of the pitch memory task (more activation in non-AP musicians. Non-significant between-group trends were seen in the posterior IFG (more in AP musicians and the IPL (more anterior activations in the non-AP group and more posterior activations in the AP group. Conclusion Since the increased activation of the left STS in AP musicians was observed during the early perceptual encoding phase and since the STS has been shown to be involved in categorization tasks, its activation might suggest that AP musicians involve categorization regions in tonal tasks. The increased activation of the right SPL/IPS in non-AP musicians indicates either an increased use of regions that are part of a tonal working memory (WM network, or the use of a multimodal encoding strategy such as the utilization of a visual-spatial mapping scheme (i.e., imagining notes on a staff or using a spatial coding for their relative pitch height for pitch

  1. Improved fiberoptic spectrophotometer

    Science.gov (United States)

    Tans, P.P.; Lashof, D.A.

    1985-04-02

    The present invention allows for accurate spectrophotmetric comparison of the Raman scattering from a sample gas with the Raman scattering from a known gas via a novel fiber optic network. The need for complicated electronic of optical circuit balancing, control, or error compensation circuitry is eliminated. The laser cavity is split into two regions, one of which houses the plasma discharge and produces laser power, and the other of which is adapted to house tubes containing the gas samples. Light from the laser source is beamed simultaneously through samples of the reference gas and the unknown gas, and Raman-scattered light is emitted. The Raman-scattered light from the known and unknown mixtures is then alternately passed through a fiber optic network where the various wavelengths are spatially mixed. The mixed light is then passed into a system of light detectors, each of which are adapted to measure one of the wavelengths of light representing a constituent element of the gases. When the test is complete, each gas sample can be assigned a Raman-scattered profile from the data consisting of the ratios each of the constituent elements bear to each other. (LEW)

  2. Absolute marine gravimetry with matter-wave interferometry.

    Science.gov (United States)

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.

  3. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Science.gov (United States)

    van Zon, Sander K R; Bültmann, Ute; Mendes de Leon, Carlos F; Reijneveld, Sijmen A

    2015-01-01

    The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender. The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender. Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups. Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and health outcome

  4. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  5. Absolute transition probabilities for 559 strong lines of neutral cerium

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J, E-mail: jjcurry@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)

    2009-07-07

    Absolute radiative transition probabilities are reported for 559 strong lines of neutral cerium covering the wavelength range 340-880 nm. These transition probabilities are obtained by scaling published relative line intensities (Meggers et al 1975 Tables of Spectral Line Intensities (National Bureau of Standards Monograph 145)) with a smaller set of published absolute transition probabilities (Bisson et al 1991 J. Opt. Soc. Am. B 8 1545). All 559 new values are for lines for which transition probabilities have not previously been available. The estimated relative random uncertainty of the new data is +-35% for nearly all lines.

  6. Strongly nonlinear theory of rapid solidification near absolute stability

    Science.gov (United States)

    Kowal, Katarzyna N.; Altieri, Anthony L.; Davis, Stephen H.

    2017-10-01

    We investigate the nonlinear evolution of the morphological deformation of a solid-liquid interface of a binary melt under rapid solidification conditions near two absolute stability limits. The first of these involves the complete stabilization of the system to cellular instabilities as a result of large enough surface energy. We derive nonlinear evolution equations in several limits in this scenario and investigate the effect of interfacial disequilibrium on the nonlinear deformations that arise. In contrast to the morphological stability problem in equilibrium, in which only cellular instabilities appear and only one absolute stability boundary exists, in disequilibrium the system is prone to oscillatory instabilities and a second absolute stability boundary involving attachment kinetics arises. Large enough attachment kinetics stabilize the oscillatory instabilities. We derive a nonlinear evolution equation to describe the nonlinear development of the solid-liquid interface near this oscillatory absolute stability limit. We find that strong asymmetries develop with time. For uniform oscillations, the evolution equation for the interface reduces to the simple form f''+(βf')2+f =0 , where β is the disequilibrium parameter. Lastly, we investigate a distinguished limit near both absolute stability limits in which the system is prone to both cellular and oscillatory instabilities and derive a nonlinear evolution equation that captures the nonlinear deformations in this limit. Common to all these scenarios is the emergence of larger asymmetries in the resulting shapes of the solid-liquid interface with greater departures from equilibrium and larger morphological numbers. The disturbances additionally sharpen near the oscillatory absolute stability boundary, where the interface becomes deep-rooted. The oscillations are time-periodic only for small-enough initial amplitudes and their frequency depends on a single combination of physical parameters, including the

  7. A note on unique solvability of the absolute value equation

    Directory of Open Access Journals (Sweden)

    Taher Lotfi

    2014-05-01

    Full Text Available It is proved that applying sufficient regularity conditions to the interval matrix $[A-|B|,A+|B|]$‎, ‎we can create a new unique solvability condition for the absolute value equation $Ax+B|x|=b$‎, ‎since regularity of interval matrices implies unique solvability of their corresponding absolute value equation‎. ‎This condition is formulated in terms of positive definiteness of a certain point matrix‎. ‎Special case $B=-I$ is verified too as an application.

  8. Absolute decay parametric instability of high-temperature plasma

    International Nuclear Information System (INIS)

    Zozulya, A.A.; Silin, V.P.; Tikhonchuk, V.T.

    1986-01-01

    A new absolute decay parametric instability having wide spatial localization region is shown to be possible near critical plasma density. Its excitation is conditioned by distributed feedback of counter-running Langmuir waves occurring during parametric decay of incident and reflected pumping wave components. In a hot plasma with the temperature of the order of kiloelectronvolt its threshold is lower than that of a known convective decay parametric instability. Minimum absolute instability threshold is shown to be realized under conditions of spatial parametric resonance of higher orders

  9. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron

    2014-01-01

    numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model...... is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken...

  10. The bolometric, infrared and visual absolute magnitudes of Mira variables

    International Nuclear Information System (INIS)

    Robertson, B.S.C.; Feast, M.W.

    1981-01-01

    Statistical parallaxes, as well as stars with individually known distances are used to derive bolometric and infrared absolute magnitudes of Mira (Me) variables. The derived bolometric magnitudes are in the mean about 0.75 mag fainter than recent estimates. The problem of determining the pulsation constant is discussed. Miras with periods greater than 150 days probably pulsate in the first overtone. Those of shorter periods are anomalous and may be fundamental pulsators. It is shown that the absolute visual magnitudes at mean light of Miras with individually determined distances are consistent with values derived by Clayton and Feast from statistical parallaxes. (author)

  11. Support Vector Machine and Artificial Neural Network Models for the Classification of Grapevine Varieties Using a Portable NIR Spectrophotometer.

    Science.gov (United States)

    Gutiérrez, Salvador; Tardaguila, Javier; Fernández-Novales, Juan; Diago, María P

    2015-01-01

    The identification of different grapevine varieties, currently attended using visual ampelometry, DNA analysis and very recently, by hyperspectral analysis under laboratory conditions, is an issue of great importance in the wine industry. This work presents support vector machine and artificial neural network's modelling for grapevine varietal classification from in-field leaf spectroscopy. Modelling was attempted at two scales: site-specific and a global scale. Spectral measurements were obtained on the near-infrared (NIR) spectral range between 1600 to 2400 nm under field conditions in a non-destructive way using a portable spectrophotometer. For the site specific approach, spectra were collected from the adaxial side of 400 individual leaves of 20 grapevine (Vitis vinifera L.) varieties one week after veraison. For the global model, two additional sets of spectra were collected one week before harvest from two different vineyards in another vintage, each one consisting on 48 measurement from individual leaves of six varieties. Several combinations of spectra scatter correction and smoothing filtering were studied. For the training of the models, support vector machines and artificial neural networks were employed using the pre-processed spectra as input and the varieties as the classes of the models. The results from the pre-processing study showed that there was no influence whether using scatter correction or not. Also, a second-degree derivative with a window size of 5 Savitzky-Golay filtering yielded the highest outcomes. For the site-specific model, with 20 classes, the best results from the classifiers thrown an overall score of 87.25% of correctly classified samples. These results were compared under the same conditions with a model trained using partial least squares discriminant analysis, which showed a worse performance in every case. For the global model, a 6-class dataset involving samples from three different vineyards, two years and leaves

  12. Support Vector Machine and Artificial Neural Network Models for the Classification of Grapevine Varieties Using a Portable NIR Spectrophotometer.

    Directory of Open Access Journals (Sweden)

    Salvador Gutiérrez

    Full Text Available The identification of different grapevine varieties, currently attended using visual ampelometry, DNA analysis and very recently, by hyperspectral analysis under laboratory conditions, is an issue of great importance in the wine industry. This work presents support vector machine and artificial neural network's modelling for grapevine varietal classification from in-field leaf spectroscopy. Modelling was attempted at two scales: site-specific and a global scale. Spectral measurements were obtained on the near-infrared (NIR spectral range between 1600 to 2400 nm under field conditions in a non-destructive way using a portable spectrophotometer. For the site specific approach, spectra were collected from the adaxial side of 400 individual leaves of 20 grapevine (Vitis vinifera L. varieties one week after veraison. For the global model, two additional sets of spectra were collected one week before harvest from two different vineyards in another vintage, each one consisting on 48 measurement from individual leaves of six varieties. Several combinations of spectra scatter correction and smoothing filtering were studied. For the training of the models, support vector machines and artificial neural networks were employed using the pre-processed spectra as input and the varieties as the classes of the models. The results from the pre-processing study showed that there was no influence whether using scatter correction or not. Also, a second-degree derivative with a window size of 5 Savitzky-Golay filtering yielded the highest outcomes. For the site-specific model, with 20 classes, the best results from the classifiers thrown an overall score of 87.25% of correctly classified samples. These results were compared under the same conditions with a model trained using partial least squares discriminant analysis, which showed a worse performance in every case. For the global model, a 6-class dataset involving samples from three different vineyards, two years

  13. Measured and modelled absolute gravity changes in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil; Forsberg, René; Strykowski, Gabriel

    2014-01-01

    in Greenland. Theresult is compared with the initial measurements of absolute gravity (AG) change at selected GreenlandNetwork (GNET) sites.We find that observations are highly influenced by the direct attraction from the ice and ocean. Thisis especially evident in the measurements conducted at the GNET...

  14. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Pie Valls, B; Pietrzyk, B; Pilar, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; du Pree, T; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shao, B; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skottowe, H P; Skwarnicki, T; Smith, A C; Smith, N A; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Styles, N; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Vervink, K; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Voong, D; Vorobyev, A; Voss, H; Wacker, K; Wandernoth, S; Wang, J; Ward, D R; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  15. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    Science.gov (United States)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  16. Absolute configurations of zingiberenols isolated from ginger (Zingiber officinale) rhizomes

    Science.gov (United States)

    The sesquiterpene alcohol zingiberenol, or 1,10-bisaboladien-3-ol, was isolated some time ago from ginger, Zingiber officinale, rhizomes, but its absolute configuration had not been determined. With three chiral centers present in the molecule, zingiberenol can exist in eight stereoisomeric forms. ...

  17. Fabricating the absolute fake: America in contemporary pop culture

    NARCIS (Netherlands)

    Kooijman, J.

    2008-01-01

    Onze wereld wordt gedomineerd door de Amerikaanse popcultuur. Fabricating the Absolute Fake onderzoekt de dynamiek van Amerikanisering aan de hand van hedendaagse films, televisieprogramma's en popsterren die reflecteren op de vraag wat het betekent om Amerikaan in een mondiale popcultuur te zijn.

  18. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.

    2011-04-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional support for our model of enantioinduction in the palladium(II)-catalyzed oxidative kinetic resolution of secondary alcohols. © 2010 Elsevier Ltd. All rights reserved.

  19. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  20. The Absolute and the Relative Dimensions of Constitutional Rights

    Czech Academy of Sciences Publication Activity Database

    Alexy, Robert

    2017-01-01

    Roč. 37, č. 1 (2017), s. 31-47 ISSN 0143-6503 Keywords : constitutional rights * judicial review * proportionality Subject RIV: AG - Legal Sciences OBOR OECD: Law Impact factor: 1.242, year: 2016 https://academic.oup.com/ojls/article/37/1/31/2669583/The-Absolute-and-the-Relative-Dimensions-of

  1. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    Science.gov (United States)

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises,…

  2. Absolute configuration of some dinorlabdanes from the copaiba oil

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Adriano L.; Baptistela, Lucia H.B.; Imamura, Paulo M. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Inst. de Quimica], e-mail: imam@iqm.unicamp.br

    2009-07-01

    A novel ent-dinorlabdane ({iota})-13(R)-14,15-dinorlabd-8(17)-ene-3,13-diol was isolated from commercial copaiba oil along with two known dinorlabdanes. The absolute configuration of these dinorditerpenes was established for the first time through synthesis starting from known ({iota})-3-hydroxycopalic acid, which was also isolated from the same oleoresin. (author)

  3. Absolute Risk Aversion and the Returns to Education.

    Science.gov (United States)

    Brunello, Giorgio

    2002-01-01

    Uses 1995 Italian household income and wealth survey to measure individual absolute risk aversion of 1,583 married Italian male household heads. Uses this measure as an instrument for attained education in a standard-log earnings equation. Finds that the IV estimate of the marginal return to schooling is much higher than the ordinary least squares…

  4. Absolute differential yield of parametric x-ray radiation

    International Nuclear Information System (INIS)

    Shchagin, A.V.; Pristupa, V.I.; Khizhnyak, N.A.

    1993-01-01

    The results of measurements of absolute differential yield of parametric X-ray radiation (PXR) in thin single crystal are presented for the first time. It has been established that the experimental results are in good agreement with theoretical calculations according with kinematical theory. The influence of density effect on PXR properties is discussed. (author). 19 refs., 7 figs

  5. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    NARCIS (Netherlands)

    Hernandez, E. M.; Juarez, A. M.; Kilcoyne, A. L. D.; Aguilar, A.; Hernandez, L.; Antillon, A.; Macaluso, D.; Morales-Mori, A.; Gonzalez-Magana, O.; Hanstorp, D.; Covington, A. M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    The photoionization of Cl+ leading to Cl2+ was measured in the photon energy range of 19.5-28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl+ ion beam with a photon beam of

  6. Comments on the theory of absolute and convective instabilities

    International Nuclear Information System (INIS)

    Oscarsson, T.E.; Roennmark, K.

    1986-10-01

    The theory of absolute and convective instabilities is discussed and we argue that the basis of the theory is questionable, since it describes the linear development of instabilities by their behaviour in the time asymptotic limit. In order to make sensible predictions on the linear development of instabilities, the problem should be studied on the finite time scale implied by the linear approximation. (authors)

  7. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2017-01-01

    The widely applied “dollar-a-day” methodology identifies global absolute poverty as declining precipitously since the early 80’s throughout the developing world. The methodological underpinnings of the “dollar-a-day” approach have been questioned in terms of adequately representing equivalent

  8. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2015-01-01

    The global absolute poverty rates of the World Bank demonstrate a continued decline of poverty in developing countries between 1983 and 2012. However, the methodology applied to derive these results has received extensive criticism by scholars for requiring the application of PPP exchange rates and

  9. Population-based absolute risk estimation with survey data

    Science.gov (United States)

    Kovalchik, Stephanie A.; Pfeiffer, Ruth M.

    2013-01-01

    Absolute risk is the probability that a cause-specific event occurs in a given time interval in the presence of competing events. We present methods to estimate population-based absolute risk from a complex survey cohort that can accommodate multiple exposure-specific competing risks. The hazard function for each event type consists of an individualized relative risk multiplied by a baseline hazard function, which is modeled nonparametrically or parametrically with a piecewise exponential model. An influence method is used to derive a Taylor-linearized variance estimate for the absolute risk estimates. We introduce novel measures of the cause-specific influences that can guide modeling choices for the competing event components of the model. To illustrate our methodology, we build and validate cause-specific absolute risk models for cardiovascular and cancer deaths using data from the National Health and Nutrition Examination Survey. Our applications demonstrate the usefulness of survey-based risk prediction models for predicting health outcomes and quantifying the potential impact of disease prevention programs at the population level. PMID:23686614

  10. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos; Ketcheson, David I.

    2014-01-01

    -Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend

  11. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    Abstract. The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is ...

  12. Absolute parametric instability in a nonuniform plane plasma

    Indian Academy of Sciences (India)

    The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is considered.

  13. Absolute configuration and antiprotozoal activity of minquartynoic acid

    DEFF Research Database (Denmark)

    Rasmussen, H B; Christensen, Søren Brøgger; Kvist, L P

    2000-01-01

    Minquartynoic acid (1) was isolated as an antimalarial and antileishmanial constituent of the Peruvian tree Minquartia guianensis and its absolute configuration at C-17 established to be (+)-S through conversion to the known (+)-(S)-17-hydroxystearic acid (2) and confirmed using Mosher's method....

  14. Relative versus Absolute Stimulus Control in the Temporal Bisection Task

    Science.gov (United States)

    de Carvalho, Marilia Pinhiero; Machado, Armando

    2012-01-01

    When subjects learn to associate two sample durations with two comparison keys, do they learn to associate the keys with the short and long samples (relational hypothesis), or with the specific sample durations (absolute hypothesis)? We exposed 16 pigeons to an ABA design in which phases A and B corresponded to tasks using samples of 1 s and 4 s,…

  15. Absolute intensity calibration for ECE measurements on EAST

    International Nuclear Information System (INIS)

    Liu Yong; Liu Xiang; Zhao Hailin

    2014-01-01

    In this proceeding, the results of the in-situ absolute intensity calibration for ECE measurements on EAST are presented. A 32-channel heterodyne radiometer system and a Michelson interferometer on EAST have been calibrated independently, and preliminary results from plasma operation indicate a good agreement between the electron temperature profiles obtained with different systems. (author)

  16. Absolute dissipative drift-wave instabilities in tokamaks

    International Nuclear Information System (INIS)

    Chen, L.; Chance, M.S.; Cheng, C.Z.

    1979-07-01

    Contrary to previous theoretical predictions, it is shown that the dissipative drift-wave instabilities are absolute in tokamak plasmas. The existence of unstable eigenmodes is shown to be associated with a new eigenmode branch induced by the finite toroidal couplings

  17. On quantum harmonic oscillator being subjected to absolute ...

    Indian Academy of Sciences (India)

    On quantum harmonic oscillator being subjected to absolute potential state. SWAMI NITYAYOGANANDA. Ramakrishna Mission Ashrama, R.K. Beach, Visakhapatnam 530 003, India. E-mail: nityayogananda@gmail.com. MS received 1 May 2015; accepted 6 May 2016; published online 3 December 2016. Abstract.

  18. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the ∑ n ≤ N f(n)$ with explicit error term. As a corollary we obtain new results about sum-of-divisors functions and Jordan's totient functions.

  19. Absolute Gravity Datum in the Age of Cold Atom Gravimeters

    Science.gov (United States)

    Childers, V. A.; Eckl, M. C.

    2014-12-01

    The international gravity datum is defined today by the International Gravity Standardization Net of 1971 (IGSN-71). The data supporting this network was measured in the 1950s and 60s using pendulum and spring-based gravimeter ties (plus some new ballistic absolute meters) to replace the prior protocol of referencing all gravity values to the earlier Potsdam value. Since this time, gravimeter technology has advanced significantly with the development and refinement of the FG-5 (the current standard of the industry) and again with the soon-to-be-available cold atom interferometric absolute gravimeters. This latest development is anticipated to provide improvement in the range of two orders of magnitude as compared to the measurement accuracy of technology utilized to develop ISGN-71. In this presentation, we will explore how the IGSN-71 might best be "modernized" given today's requirements and available instruments and resources. The National Geodetic Survey (NGS), along with other relevant US Government agencies, is concerned about establishing gravity control to establish and maintain high order geodetic networks as part of the nation's essential infrastructure. The need to modernize the nation's geodetic infrastructure was highlighted in "Precise Geodetic Infrastructure, National Requirements for a Shared Resource" National Academy of Science, 2010. The NGS mission, as dictated by Congress, is to establish and maintain the National Spatial Reference System, which includes gravity measurements. Absolute gravimeters measure the total gravity field directly and do not involve ties to other measurements. Periodic "intercomparisons" of multiple absolute gravimeters at reference gravity sites are used to constrain the behavior of the instruments to ensure that each would yield reasonably similar measurements of the same location (i.e. yield a sufficiently consistent datum when measured in disparate locales). New atomic interferometric gravimeters promise a significant

  20. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  1. In vitro kinetics of P700+ reduction of Thermosynechococcus elongatus trimeric Photosystem I complexes by recombinant cytochrome c 6 using a Joliot-type LED spectrophotometer.

    Science.gov (United States)

    Nguyen, Khoa; Vaughn, Michael; Frymier, Paul; Bruce, Barry D

    2017-01-01

    The reduction rate of photo-oxidized Photosystem I (PSI) with various natural and artificial electron donors have been well studied by transient absorption spectroscopy. The electron transfer rate from various donors to P 700 + has been measured for a wide range of photosynthetic organisms encompassing cyanobacteria, algae, and plants. PSI can be a limiting component due to tedious extraction and purification methods required for this membrane protein. In this report, we have determined the in vivo, intracellular cytochrome c 6 (cyt c 6 )/PSI ratio in Thermosynechococcus elongatus (T.e.) using quantitative Western blot analysis. This information permitted the determination of P 700 + reduction kinetics via recombinant cyt c 6 in a physiologically relevant ratio (cyt c 6 : PSI) with a Joliot-type, LED-driven, pump-probe spectrophotometer. Dilute PSI samples were tested under varying cyt c 6 concentration, temperature, pH, and ionic strength, each of which shows similar trends to the reported literature utilizing much higher PSI concentrations with laser-based spectrophotometer. Our results do however indicate kinetic differences between actinic light sources (laser vs. LED), and we have attempted to resolve these effects by varying our LED light intensity and duration. The standardized configuration of this spectrophotometer will also allow a more uniform kinetic analysis of samples in different laboratories. We can conclude that our findings from the LED-based system display an added total protein concentration effect due to multiple turnover events of P 700 + reduction by cyt c 6 during the longer illumination regime.

  2. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB.

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho; Kim, Young-Hun

    2009-05-01

    Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm(2). We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm(2) range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is

  3. Proposal for an absolute, atomic definition of mass

    International Nuclear Information System (INIS)

    Wignall, J.W.G.

    1991-11-01

    It is proposed that the mass of a particle be defined absolutely as its de Broglie frequency, measured as the mean de Broglie wavelength of the particle when it has a mean speed (v) and Lorentz factor γ; the masses of systems too large to have a measurable de Broglie wavelength mean are then to be derived by specifying the usual inertial and additive properties of mass. This definition avoids the use of an arbitrary macroscopic standard such as the prototype kilogram, and, if present theory is correct, does not even require the choice of a specific particle as a mass standard. Suggestions are made as to how this absolute mass can be realized and measured at the macroscopic level and, finally, some comments are made on the effect of the new definition on the form of the equations of physics. 19 refs

  4. Remote ultrasound palpation for robotic interventions using absolute elastography.

    Science.gov (United States)

    Schneider, Caitlin; Baghani, Ali; Rohling, Robert; Salcudean, Septimiu

    2012-01-01

    Although robotic surgery has addressed many of the challenges presented by minimally invasive surgery, haptic feedback and the lack of knowledge of tissue stiffness is an unsolved problem. This paper presents a system for finding the absolute elastic properties of tissue using a freehand ultrasound scanning technique, which utilizes the da Vinci Surgical robot and a custom 2D ultrasound transducer for intraoperative use. An external exciter creates shear waves in the tissue, and a local frequency estimation method computes the shear modulus. Results are reported for both phantom and in vivo models. This system can be extended to any 6 degree-of-freedom tracking method and any 2D transducer to provide real-time absolute elastic properties of tissue.

  5. Absolute limit on rotation of gravitationally bound stars

    Science.gov (United States)

    Glendenning, N. K.

    1994-03-01

    The authors seek an absolute limit on the rotational period for a neutron star as a function of its mass, based on the minimal constraints imposed by Einstein's theory of relativity, Le Chatelier's principle, causality, and a low-density equation of state, uncertainties which can be evaluated as to their effect on the result. This establishes a limiting curve in the mass-period plane below which no pulsar that is a neutron star can lie. For example, the minimum possible Kepler period, which is an absolute limit on rotation below which mass-shedding would occur, is 0.33 ms for a M = 1.442 solar mass neutron star (the mass of PSR1913+16). If the limit were found to be broken by any pulsar, it would signal that the confined hadronic phase of ordinary nucleons and nuclei is only metastable.

  6. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  7. Absolute elastic cross sections for electron scattering from SF6

    International Nuclear Information System (INIS)

    Gulley, R.J.; Uhlmann, L.J.; Dedman, C.J.; Buckman, S.J.; Cho, H.; Trantham, K.W.

    2000-01-01

    Full text: Absolute differential cross sections for vibrationally elastic scattering of electrons from sulphur hexafluoride (SF 6 ) have been measured at fixed angles of 60 deg, 90 deg and 120 deg over the energy range of 5 to 15 eV, and also at 11 fixed energies between 2.7 and 75 eV for scattering angles between 10 deg and 180 deg. These measurements employ the magnetic angle-changing technique of Read and Channing in combination with the relative flow technique to obtain absolute elastic scattering cross sections at backward angles (135 deg to 180 deg) for incident energies below 15 eV. The results reveal some substantial differences with several previous determinations and a reasonably good level of agreement with a recent close coupling calculation

  8. ABSOLUTE AND COMPARATIVE SUSTAINABILITY OF FARMING ENTERPRISES IN BULGARIA

    Directory of Open Access Journals (Sweden)

    H. Bachev

    2017-04-01

    Full Text Available Evaluating absolute and comparative sustainability of farming enterprises is among the most topical issues for researchers, farmers, investors, administrators, politicians, interests groups and public at large. Nevertheless, in Bulgaria and most East European countries there are no comprehensive assessments on sustainability level of Bulgarian farms of different juridical type. This article applies a holistic framework and assesses absolute and comparative sustainability major farming structures in Bulgaria - unregistered farms of Natural Persons, Sole Traders, Cooperatives, and Companies. First, method of the study is outlined, and overall characteristics of surveyed farming enterprises presented. After that an assessment is made of integral, governance, economic, social, environmental sustainability of farming structures of different juridical type. Next, structure of farming enterprises with different sustainability levels is analyzed. Finally, conclusion from the study and directions for further research and amelioration of sustainability assessments suggested.

  9. Absolute dating of the Aegean Late Bronze Age

    International Nuclear Information System (INIS)

    Warren, P.M.

    1987-01-01

    A recent argument for raising the absolute date of the beginning of the Aegean Late Bronze (LB) Age to about 1700 B.C. is critically examined. It is argued here that: (1) the alabaster lid from Knossos did have the stratigraphical context assigned to it by Evans, in all probability Middle Minoan IIIA, c. 1650 B.C.; (2) the attempt to date the alabastron found in an early Eighteenth Dynasty context at Aniba to Late Minoan IIIA:1 is open to objections; (3) radiocarbon dates from Aegean LB I contexts are too wide in their calibrated ranges and too inconsistent both within and between site sets to offer any reliable grounds at present for raising Aegean LB I absolute chronology to 1700 B.C. Other evidence, however, suggests this period began about 1600 B.C., i.e. some fifty years earlier than the conventional date of 1550 B.C. (author)

  10. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  11. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  12. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  13. Synesthesia and rhythm. The road to absolute cinema

    Directory of Open Access Journals (Sweden)

    Ricardo Roncero Palomar

    2017-05-01

    Full Text Available Absolute cinema, developed during the historical avant-garde, con-tinued with a long artistic tradition that linked musical with visual experience. Due to cinema as médium of expression, this filmmakers were able to work with the moving image to develop concepts such as rhythm, also with more complex figures than the colored spots that other devices could create at those time. This study starts with the published texts in 1704 by Newton about color, and provides an overview of those artistic highlights that link image and sound, and which creates the origins of absolute cinema. The connections and equivalences between the visual and sound experiences used by these filmmakers are also studied in order to know if there was a continuous line with the origins of these studies or if there was a rupture and other later investigations were able to have more repercussion in their works.

  14. Purely absolutely continuous spectrum for almost Mathieu operators

    International Nuclear Information System (INIS)

    Chulaevsky, V.; Delyon, F.

    1989-01-01

    Using a recent result of Sinai, the authors prove that the almost Mathieu operators acting on l 2 (Z), (H αλ Psi)(n) = Ψ(n + 1) + Ψ(n - 1) + λ cos(ωn + α) Ψ(n), have a purely absolutely continuous spectrum for almost all α provided that ω is a good irrational and λ is sufficiently small. Furthermore, the generalized eigenfunctions are quasiperiodic

  15. Absolute calibration and beam background of the Squid Polarimeter

    International Nuclear Information System (INIS)

    Blaskiewicz, M.M.; Cameron, P.R.; Shea, T.J.

    1996-01-01

    The problem of beam background in Squid Polarimetry is not without residual benefits. The authors may deliberately generate beam background by gently kicking the beam at the spin tune frequency. This signal may be used to accomplish a simple and accurate absolute calibration of the polarimeter. The authors present details of beam background calculations and their application to polarimeter calibration, and suggest a simple proof-of-principle accelerator experiment

  16. Results from a U.S. Absolute Gravity Survey,

    Science.gov (United States)

    1982-01-01

    National Bureau of Standards. La . ... ,., 831A08 NOV -2- 1. Introduction We have recently completed an absolute gravity survey at twelve sites in the...Air Force Geophysics Laboratory (AFGL) and the Istituto di Metrologia -7- "G. Colonnetti" (IMGC) [Marson and Alasia, 1978, 19801. All three...for ab- solute measurements of the earth’s gravity, Metrologia , in press, 1982. L 4 !" Table 1. Gravity values transferred to the floor in gal (cm

  17. Blastic plasmacytoid dendritic cell neoplasm with absolute monocytosis at presentation

    Directory of Open Access Journals (Sweden)

    Jaworski JM

    2015-02-01

    Full Text Available Joseph M Jaworski,1,2 Vanlila K Swami,1 Rebecca C Heintzelman,1 Carrie A Cusack,3 Christina L Chung,3 Jeremy Peck,3 Matthew Fanelli,3 Micheal Styler,4 Sanaa Rizk,4 J Steve Hou1 1Department of Pathology and Laboratory Medicine, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 2Department of Pathology, Mercy Fitzgerald Hospital, Darby, PA, USA; 3Department of Dermatology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 4Department of Hematology/Oncology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Blastic plasmacytoid dendritic cell neoplasm is an uncommon malignancy derived from precursors of plasmacytoid dendritic cells. Nearly all patients present initially with cutaneous manifestations, with many having extracutaneous disease additionally. While response to chemotherapy initially is effective, relapse occurs in most, with a leukemic phase ultimately developing. The prognosis is dismal. While most of the clinical and pathologic features are well described, the association and possible prognostic significance between peripheral blood absolute monocytosis (>1.0 K/µL and blastic plasmacytoid dendritic cell neoplasm have not been reported. We report a case of a 68-year-old man who presented with a rash for 4–5 months. On physical examination, there were multiple, dull-pink, indurated plaques on the trunk and extremities. Complete blood count revealed thrombocytopenia, absolute monocytosis of 1.7 K/µL, and a negative flow cytometry study. Biopsy of an abdominal lesion revealed typical features of blastic plasmacytoid dendritic cell neoplasm. Patients having both hematologic and nonhematologic malignancies have an increased incidence of absolute monocytosis. Recent studies examining Hodgkin and non-Hodgkin lymphoma patients have suggested that this is a negative prognostic factor. The association between

  18. Definition of correcting factors for absolute radon content measurement formula

    International Nuclear Information System (INIS)

    Ji Changsong; Xiao Ziyun; Yang Jianfeng

    1992-01-01

    The absolute method of radio content measurement is based on thomas radon measurement formula. It was found in experiment that the systematic error existed in radon content measurement by means of thomas formula. By the analysis on the behaviour of radon daughter five factors including filter efficiency, detector construction factor, self-absorbance, energy spectrum factor, and gravity factor were introduced into the thomas formula, so that the systematic error was eliminated. The measuring methods of the five factors are given

  19. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    International Nuclear Information System (INIS)

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1 rc covering ∼2600-3300 A after removing optical light, and u ∼ 3000-4000 A) compared to a mid-UV filter (uvm2 ∼2000-2400 A). The uvw1 rc - b colors show a scatter of ∼0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, ∼1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  20. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  1. Improved Harmony Search Algorithm with Chaos for Absolute Value Equation

    Directory of Open Access Journals (Sweden)

    Shouheng Tuo

    2013-11-01

    Full Text Available In this paper, an improved harmony search with chaos (HSCH is presented for solving NP-hard absolute value equation (AVE Ax - |x| = b, where A is an arbitrary square matrix whose singular values exceed one. The simulation results in solving some given AVE problems demonstrate that the HSCH algorithm is valid and outperforms the classical HS algorithm (CHS and HS algorithm with differential mutation operator (HSDE.

  2. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    International Nuclear Information System (INIS)

    Sannibale, F.; Stupakov, G.V.; Zolotorev, M.S.; Filippetto, D.; Jagerhofer, L.

    2009-01-01

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  3. Absolute efficiency calibration of HPGe detector by simulation method

    International Nuclear Information System (INIS)

    Narayani, K.; Pant, Amar D.; Verma, Amit K.; Bhosale, N.A.; Anilkumar, S.

    2018-01-01

    High resolution gamma ray spectrometry by HPGe detectors is a powerful radio analytical technique for estimation of activity of various radionuclides. In the present work absolute efficiency calibration of the HPGe detector was carried out using Monte Carlo simulation technique and results are compared with those obtained by experiment using standard radionuclides of 152 Eu and 133 Ba. The coincidence summing correction factors for the measurement of these nuclides were also calculated

  4. Absolute Pitch: Effects of Timbre on Note-Naming Ability

    OpenAIRE

    Vanzella, Patr?cia; Schellenberg, E. Glenn

    2010-01-01

    Background Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP poss...

  5. Assembler absolute forward thick-target bremsstrahlung spectra program

    International Nuclear Information System (INIS)

    Niculescu, V.I.R.; Baciu, G.; Ionescu-Bujor, M.

    1981-12-01

    The program is intended to compute the absolute forward thick-target bremsstrahlung spectrum for electrons in the energy range 1-24 MeV. The program takes into account the following phenomena: multiple scattering, energy loss and the attenuation of the emitted gamma rays. The computer program is written in Assembler having a higher degree of generality and is more performant than the FORTRAN version. (authors)

  6. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    Directory of Open Access Journals (Sweden)

    Sammie eTarenskeen

    2015-11-01

    Full Text Available The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a between-participants design, however, we find similar rates of pattern and size overspecification, which are both lower than the rate of colour overspecification. This indicates that although many speakers are more likely to include colour than pattern (probably because colour is more salient, they may also treat pattern like colour due to a tendency towards consistency. We find no increase in size overspecification when the salience of size is increased, suggesting that speakers are more likely to include absolute than relative attributes. However, we do find an increase in size overspecification when mentioning the attributes is triggered, which again shows that speakers tend refer in a consistent manner, and that there are circumstances in which even size overspecification is frequently produced.

  7. Philosophy as Inquiry Aimed at the Absolute Knowledge

    Directory of Open Access Journals (Sweden)

    Ekaterina Snarskaya

    2017-09-01

    Full Text Available Philosophy as the absolute knowledge has been studied from two different but closely related approaches: historical and logical. The first approach exposes four main stages in the history of European metaphysics that marked out types of “philosophical absolutism”: the evolution of philosophy brought to light metaphysics of being, method, morals and logic. All of them are associated with the names of Aristotle, Bacon/Descartes, Kant and Hegel. Then these forms are considered in the second approach that defined them as subject-matter of philosophy as such. Due to their overall, comprehensive character, the focus of philosophy on them justifies its claim on absoluteness as far as philosophy is aimed at comprehension of the world’s unity regardless of the philosopher’s background, values and other preferences. And that is its prerogative since no other form of consciousness lays down this kind of aim. Thus, philosophy is defined as an everlasting attempt to succeed in conceiving the world in all its multifold manifestations. This article is to try to clarify the claim of philosophy on the absolute knowledge.

  8. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  9. A vibration correction method for free-fall absolute gravimeters

    Science.gov (United States)

    Qian, J.; Wang, G.; Wu, K.; Wang, L. J.

    2018-02-01

    An accurate determination of gravitational acceleration, usually approximated as 9.8 m s-2, has been playing an important role in the areas of metrology, geophysics, and geodetics. Absolute gravimetry has been experiencing rapid developments in recent years. Most absolute gravimeters today employ a free-fall method to measure gravitational acceleration. Noise from ground vibration has become one of the most serious factors limiting measurement precision. Compared to vibration isolators, the vibration correction method is a simple and feasible way to reduce the influence of ground vibrations. A modified vibration correction method is proposed and demonstrated. A two-dimensional golden section search algorithm is used to search for the best parameters of the hypothetical transfer function. Experiments using a T-1 absolute gravimeter are performed. It is verified that for an identical group of drop data, the modified method proposed in this paper can achieve better correction effects with much less computation than previous methods. Compared to vibration isolators, the correction method applies to more hostile environments and even dynamic platforms, and is expected to be used in a wider range of applications.

  10. Absolute photoionization cross-section of the propargyl radical

    Energy Technology Data Exchange (ETDEWEB)

    Savee, John D.; Welz, Oliver; Taatjes, Craig A.; Osborn, David L. [Sandia National Laboratories, Combustion Research Facility, Livermore, California 94551 (United States); Soorkia, Satchin [Institut des Sciences Moleculaires d' Orsay, Universite Paris-Sud 11, Orsay (France); Selby, Talitha M. [Department of Chemistry, University of Wisconsin, Washington County Campus, West Bend, Wisconsin 53095 (United States)

    2012-04-07

    Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

  11. An absolute distance interferometer with two external cavity diode lasers

    International Nuclear Information System (INIS)

    Hartmann, L; Meiners-Hagen, K; Abou-Zeid, A

    2008-01-01

    An absolute interferometer for length measurements in the range of several metres has been developed. The use of two external cavity diode lasers allows the implementation of a two-step procedure which combines the length measurement with a variable synthetic wavelength and its interpolation with a fixed synthetic wavelength. This synthetic wavelength is obtained at ≈42 µm by a modulation-free stabilization of both lasers to Doppler-reduced rubidium absorption lines. A stable reference interferometer is used as length standard. Different contributions to the total measurement uncertainty are discussed. It is shown that the measurement uncertainty can considerably be reduced by correcting the influence of vibrations on the measurement result and by applying linear regression to the quadrature signals of the absolute interferometer and the reference interferometer. The comparison of the absolute interferometer with a counting interferometer for distances up to 2 m results in a linearity error of 0.4 µm in good agreement with an estimation of the measurement uncertainty

  12. Absolute surface reconstruction by slope metrology and photogrammetry

    Science.gov (United States)

    Dong, Yue

    Developing the manufacture of aspheric and freeform optical elements requires an advanced metrology method which is capable of inspecting these elements with arbitrary freeform surfaces. In this dissertation, a new surface measurement scheme is investigated for such a purpose, which is to measure the absolute surface shape of an object under test through its surface slope information obtained by photogrammetric measurement. A laser beam propagating toward the object reflects on its surface while the vectors of the incident and reflected beams are evaluated from the four spots they leave on the two parallel transparent windows in front of the object. The spots' spatial coordinates are determined by photogrammetry. With the knowledge of the incident and reflected beam vectors, the local slope information of the object surface is obtained through vector calculus and finally yields the absolute object surface profile by a reconstruction algorithm. An experimental setup is designed and the proposed measuring principle is experimentally demonstrated by measuring the absolute surface shape of a spherical mirror. The measurement uncertainty is analyzed, and efforts for improvement are made accordingly. In particular, structured windows are designed and fabricated to generate uniform scattering spots left by the transmitted laser beams. Calibration of the fringe reflection instrument, another typical surface slope measurement method, is also reported in the dissertation. Finally, a method for uncertainty analysis of a photogrammetry measurement system by optical simulation is investigated.

  13. Absolutely minimal extensions of functions on metric spaces

    International Nuclear Information System (INIS)

    Milman, V A

    1999-01-01

    Extensions of a real-valued function from the boundary ∂X 0 of an open subset X 0 of a metric space (X,d) to X 0 are discussed. For the broad class of initial data coming under discussion (linearly bounded functions) locally Lipschitz extensions to X 0 that preserve localized moduli of continuity are constructed. In the set of these extensions an absolutely minimal extension is selected, which was considered before by Aronsson for Lipschitz initial functions in the case X 0 subset of R n . An absolutely minimal extension can be regarded as an ∞-harmonic function, that is, a limit of p-harmonic functions as p→+∞. The proof of the existence of absolutely minimal extensions in a metric space with intrinsic metric is carried out by the Perron method. To this end, ∞-subharmonic, ∞-superharmonic, and ∞-harmonic functions on a metric space are defined and their properties are established

  14. Absolute total cross sections for noble gas systems

    International Nuclear Information System (INIS)

    Kam, P. van der.

    1981-01-01

    This thesis deals with experiments on the elastic scattering of Ar, Kr and Xe, using the molecular beam technique. The aim of this work was the measurement of the absolute value of the total cross section and the behaviour of the total cross section, Q, as function of the relative velocity g of the scattering partners. The author gives an extensive analysis of the glory structure in the total cross section and parametrizes the experimental results using a semiclassical model function. This allows a detailed comparison of the phase and amplitude of the predicted and measured glory undulations. He indicates how the depth and position of the potential well should be changed in order to come to an optimum description of the glory structure. With this model function he has also been able to separate the glory and attractive contribution to Q, and using the results from the extrapolation measurements he has obtained absolute values for Qsub(a). From these absolute values he has calculated the parameter C 6 that determines the strength of the attractive region of the potential. In two of the four investigated gas combinations the obtained values lie outside the theoretical bounds. (Auth.)

  15. Local absolute alcohol ablation for the treatment of recurrent pheochromocytoma

    International Nuclear Information System (INIS)

    Shang Mingyi; Wang Peijun; Lu Ying; Ma Jun; Tang Junjun; Xi Qian; Huang Zongliang; Gao Xiaolong

    2010-01-01

    Objective: to assess the clinical value of local injection of absolute alcohol under CT guidance in treating recurrent pheochromocytoma. Methods: Five patients with benign recurrent pheochromocytoma were enrolled in this study. Of the five cases, the lesions were located on the right side in three, on the left in one and on both sides in one. All the lesions were pathologically proved to be benign ones. Under CT guidance the ablation therapy with local injection of absolute alcohol was performed. The therapeutic results were observed and evaluated. Results: Thirty days after the treatment, different degrees of decrease in tumor size was observed on follow-up CT scans. All the patients were followed up for 9-42 months. During the follow-up period, both the blood pressure and the vanillyl mandelic acid (VMA) level in urine remained normal and no paroxysmal dizziness, headache or syncope occurred in all patients. Conclusion: For the treatment of recurrent pheochromocytoma the ablation therapy by using local injection of absolute alcohol under CT guidance is a safe and practical therapeutic means with definite and reliable effectiveness. (authors)

  16. [The study of the colorimetric characteristics of the cobalt-chrome alloys abutments covered by four different all-ceramic crowns by using dental spectrophotometer].

    Science.gov (United States)

    Chen, Yifan; Liu, Hongchun; Meng, Yukun; Chao, Yonglie; Liu, Changhong

    2015-06-01

    This study aims to evaluate the optical data of the different sites of the cobalt-chrome (Co-Cr) alloy abutments covered by four different all-ceramic crowns and the color difference between the crowns and target tab using a digital dental spectrophotometer. Ten Co-Cr alloy abutments were made and tried in four different groups of all-ceramic crowns, namely, Procera aluminia, Procera zirconia, Lava zirconia (Lava-Zir), and IPS E.max glass-ceramic lithium disilicate-reinforced monolithic. The color data of the cervical, body, and incisal sites of the samples were recorded and analyzed by dental spectrophotometer. The CIE L*, a*, b* values were again measured after veneering. The color difference between the abutments covered by all-ceramic crowns and A2 dentine shade tab was evaluated. The L* and b* values of the abutments can be increased by all of the four groups of all-ceramic copings, but a* values were decreased in most groups. A statistical difference was observed among four groups. After being veneered, the L* values of all the copings declined slightly, and the values of a*, b* increased significantly. When compared with A2 dentine shade tab, the ΔE of the crowns was below 4. Four ceramic copings were demonstrated to promote the lightness and hue of the alloy abutments effecttively. Though the colorimetric baseline of these copings was uneven, veneer porcelain can efficiently decrease the color difference between the samples and thee target.

  17. Protoporphyrin IX induced by 5-aminolevulinic acid in bladder cancer cells in voided urine can be extracorporeally quantified using a spectrophotometer.

    Science.gov (United States)

    Nakai, Yasushi; Anai, Satoshi; Onishi, Sayuri; Masaomi, Kuwada; Tatsumi, Yoshihiro; Miyake, Makito; Chihara, Yoshitomo; Tanaka, Nobumichi; Hirao, Yoshihiko; Fujimoto, Kiyohide

    2015-06-01

    We evaluated the feasibility of photodynamic diagnosis of bladder cancer by spectrophotometric analysis of voided urine samples after extracorporeal treatment with 5-aminolevulinic acid (ALA). Sixty-one patients with bladder cancer, confirmed histologically after the transurethral resection of a bladder tumor, were recruited as the bladder cancer group, and 50 outpatients without history of urothelial carcinoma or cancer-related findings were recruited as the control group. Half of the voided urine sample was incubated with ALA (ALA-treated sample), and the rest was incubated without treatment (ALA-untreated sample). For detecting cellular protoporphyrin IX levels, intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated and ALA-untreated samples at 635 nm was calculated. The differences in the bladder cancer group were significantly greater than those in the control group (p spectrophotometer in patients with bladder cancer. Therefore, this cancer detection system has a potential for clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A new on-axis micro-spectrophotometer for combining Raman, fluorescence and UV/Vis absorption spectroscopy with macromolecular crystallography at the Swiss Light Source

    International Nuclear Information System (INIS)

    Pompidor, Guillaume; Dworkowski, Florian S. N.; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R.

    2013-01-01

    The new version MS2 of the in situ on-axis micro-spectrophotometer at the macromolecular crystallography beamline X10SA of the Swiss Light Source supports the concurrent acquisition of Raman, resonance Raman, fluorescence and UV/Vis absorption spectra along with diffraction data. The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years

  19. The new Absolute Quantum Gravimeter (AQG): first results and perspectives

    Science.gov (United States)

    Bonvalot, Sylvain; Le Moigne, Nicolas; Merlet, Sebastien; Desruelle, Bruno; Lautier-Gaud, Jean; Menoret, Vincent; Vermeulen, Pierre

    2016-04-01

    Cold atom gravimetry represents one of the most innovative evolution in gravity instrumentation since the last 20 years. The concept of measuring the gravitational acceleration by dropping atoms and the development of the first instrumental devices during this last decade quickly revealed the promising perspectives of this new generation of gravity meters enabling accurate and absolute measurements of the Earth's gravity field for a wide range of applications (geophysics, geodesy, metrology, etc.). The Absolute Quantum Gravimeter (AQG) gravity meter, developed by MUQUANS (Talence, France - http://www.muquans.com/) with the support of RESIF, the French Seismologic and Geodetic Network (http://www.resif.fr/) belongs to this new generation of instruments. It also represents the first commercial device based on the utilization of advanced matter-wave interferometry techniques, which allow to characterize precisely the vertical acceleration experienced by a cloud of cold atoms. Recently, the first operational unit (AQG01) has been achieved as a compact transportable gravimeter with the aim of satisfying absolute gravity measurements in laboratory conditions under the following specifications: measurements the μGal level at a few Hz cycling frequency, sensitivity of 50μGal/√Hz, immunity to ground vibrations, easy and quickness of operation, automated continuous data acquisition for several months, etc. In order to evaluate the current performances of the AQG01, several experiments are carried out in collaboration between RESIF user's teams and the MUQUANS manufacturer on different reference gravity sites and laboratories in France. These measurements performed in indoor conditions including simultaneous observations with classical reference gravity instruments (corner-cube absolute gravity meters, relative superconducting meters) as well with the Cold Atom Gravity meter (CAG) developed by LNE-SYRTE, lead to a first objective characterization of the performances of

  20. How calibration and reference spectra affect the accuracy of absolute soft X-ray solar irradiance measured by the SDO/EVE/ESP during high solar activity

    Science.gov (United States)

    Didkovsky, Leonid; Wieman, Seth; Woods, Thomas

    2016-10-01

    The Extreme ultraviolet Spectrophotometer (ESP), one of the channels of SDO's Extreme ultraviolet Variability Experiment (EVE), measures solar irradiance in several EUV and soft x-ray (SXR) bands isolated using thin-film filters and a transmission diffraction grating, and includes a quad-diode detector positioned at the grating zeroth-order to observe in a wavelength band from about 0.1 to 7.0 nm. The quad diode signal also includes some contribution from shorter wavelength in the grating's first-order and the ratio of zeroth-order to first-order signal depends on both source geometry, and spectral distribution. For example, radiometric calibration of the ESP zeroth-order at the NIST SURF BL-2 with a near-parallel beam provides a different zeroth-to-first-order ratio than modeled for solar observations. The relative influence of "uncalibrated" first-order irradiance during solar observations is a function of the solar spectral irradiance and the locations of large Active Regions or solar flares. We discuss how the "uncalibrated" first-order "solar" component and the use of variable solar reference spectra affect determination of absolute SXR irradiance which currently may be significantly overestimated during high solar activity.

  1. Consequences count: against absolutism at the end of life.

    Science.gov (United States)

    Snelling, Paul C

    2004-05-01

    There has been a considerable amount of debate in the nursing literature about euthanasia, and especially the distinctions between acts and omissions, and killing and letting die. These distinctions are required by opponents of euthanasia to justify allowing some cases of passive euthanasia while forbidding all cases of active euthanasia. This paper adds to the debate by arguing that the position that absolutely forbids euthanasia is theoretically inconsistent. The paper first considers the place of moral theory in analysing moral problems, within the framework of the principles of biomedical ethics. It is argued that despite a moral pluralism that operates in many areas, the legal status of euthanasia is based upon an absolute deontological position against deliberate killing, which cannot be overridden by appeals to favourable consequences. In order that certain forms of passive euthanasia can be allowed, this position allows distinctions within three pairs of concepts--acts and omissions, killing and letting die, and ordinary and extraordinary means. A further method of justifying certain actions near the end of life is the doctrine of double effect. These paired concepts and the doctrine of double effect are analysed with special reference to their consequences. The application of the doctrine of double effect and the three distinctions relies on consideration of their consequences, allowing in practice what in theory is denied. This is important because it weakens the absolute case against euthanasia, which disallows any direct consequentialist appeal. If consequences count in the application of the doctrine and the distinctions, then they should also count directly prior to their application. This strengthens the argument for active euthanasia in certain cases.

  2. Absolute Memory for Tempo in Musicians and Non-Musicians.

    Directory of Open Access Journals (Sweden)

    Irene Gratton

    Full Text Available The ability to remember tempo (the perceived frequency of musical pulse without external references may be defined, by analogy with the notion of absolute pitch, as absolute tempo (AT. Anecdotal reports and sparse empirical evidence suggest that at least some individuals possess AT. However, to our knowledge, no systematic assessments of AT have been performed using laboratory tasks comparable to those assessing absolute pitch. In the present study, we operationalize AT as the ability to identify and reproduce tempo in the absence of rhythmic or melodic frames of reference and assess these abilities in musically trained and untrained participants. We asked 15 musicians and 15 non-musicians to listen to a seven-step `tempo scale' of metronome beats, each associated to a numerical label, and then to perform two memory tasks. In the first task, participants heard one of the tempi and attempted to report the correct label (identification task, in the second, they saw one label and attempted to tap the correct tempo (production task. A musical and visual excerpt was presented between successive trials as a distractor to prevent participants from using previous tempi as anchors. Thus, participants needed to encode tempo information with the corresponding label, store the information, and recall it to give the response. We found that more than half were able to perform above chance in at least one of the tasks, and that musical training differentiated between participants in identification, but not in production. These results suggest that AT is relatively wide-spread, relatively independent of musical training in tempo production, but further refined by training in tempo identification. We propose that at least in production, the underlying motor representations are related to tactus, a basic internal rhythmic period that may provide a body-based reference for encoding tempo.

  3. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  4. Globular Clusters: Absolute Proper Motions and Galactic Orbits

    Science.gov (United States)

    Chemel, A. A.; Glushkova, E. V.; Dambis, A. K.; Rastorguev, A. S.; Yalyalieva, L. N.; Klinichev, A. D.

    2018-04-01

    We cross-match objects from several different astronomical catalogs to determine the absolute proper motions of stars within the 30-arcmin radius fields of 115 Milky-Way globular clusters with the accuracy of 1-2 mas yr-1. The proper motions are based on positional data recovered from the USNO-B1, 2MASS, URAT1, ALLWISE, UCAC5, and Gaia DR1 surveys with up to ten positions spanning an epoch difference of up to about 65 years, and reduced to Gaia DR1 TGAS frame using UCAC5 as the reference catalog. Cluster members are photometrically identified by selecting horizontal- and red-giant branch stars on color-magnitude diagrams, and the mean absolute proper motions of the clusters with a typical formal error of about 0.4 mas yr-1 are computed by averaging the proper motions of selected members. The inferred absolute proper motions of clusters are combined with available radial-velocity data and heliocentric distance estimates to compute the cluster orbits in terms of the Galactic potential models based on Miyamoto and Nagai disk, Hernquist spheroid, and modified isothermal dark-matter halo (axisymmetric model without a bar) and the same model + rotating Ferre's bar (non-axisymmetric). Five distant clusters have higher-than-escape velocities, most likely due to large errors of computed transversal velocities, whereas the computed orbits of all other clusters remain bound to the Galaxy. Unlike previously published results, we find the bar to affect substantially the orbits of most of the clusters, even those at large Galactocentric distances, bringing appreciable chaotization, especially in the portions of the orbits close to the Galactic center, and stretching out the orbits of some of the thick-disk clusters.

  5. Ablation of tumor and inflammatory tissue with absolute ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Uflacker, R.; Paolini, R.M.; Nobrega, M.

    Absolute ethanol was used to ablate tumors, inflammatory lesions, and end-stage nephrosclerotic kidneys in 38 patients. Thirty patients had various types of renal tumors, and 3 had chronic end-stage renal failure with malignant hypertension. One patient had a fibrosarcoma of the right leg and one had a metastatis in the humerus from a renal carcinoma. A large adrenal carcinoma was treated with absolute ethanol in a patient who had liver metastases that were ablated one year after the first procedure. An additional patient had metastatic liver disease from a non-functioning adrenal carcinoma. The remaining patient had an extensive hypervascular inflammatory lesion (tuberculosis and aspergilloma) of the right upper pulmonary lobe. In addition to ethanol, coils were introduced in one patient and Gelfoam in another. The amount of ethanol used ranged from 5 to 50 ml. Twenty-two patients suffered from considerable transient pain during ethanol injection, but sedation was necessary in only 3 of them. Skin necrosis appeared in 2 patients requiring plastic reconstruction in one of them. Two patients died within 5 days of the procedure unrelated to the ablation. Two patients presented upper gastrointestinal bleeding within 2 days of the ethanol injection and one of these died in acute renal failure. One patient suffered from left colonic infarction after left renal tumor ablation, but survived for several months. Absolute ethanol was a useful and efficient sclerosing agent causing extensive tumor destruction and marked reduction of the vascularity in tumor and inflammatory lesions, but caused an 18% complication rate.

  6. 3D measurement of absolute radiation dose in grid therapy

    International Nuclear Information System (INIS)

    Trapp, J V; Warrington, A P; Partridge, M; Philps, A; Leach, M O; Webb, S

    2004-01-01

    Spatially fractionated radiotherapy through a grid is a concept which has a long history and was routinely used in orthovoltage radiation therapy in the middle of last century to minimize damage to the skin and subcutaneous tissue. With the advent of megavoltage radiotherapy and its skin sparing effects the use of grids in radiotherapy declined in the 1970s. However there has recently been a revival of the technique for use in palliative treatments with a single fraction of 10 to 20 Gy. In this work the absolute 3D dose distribution in a grid irradiation is measured for photons using a combination of film and gel dosimetry

  7. Optimal quantum error correcting codes from absolutely maximally entangled states

    Science.gov (United States)

    Raissi, Zahra; Gogolin, Christian; Riera, Arnau; Acín, Antonio

    2018-02-01

    Absolutely maximally entangled (AME) states are pure multi-partite generalizations of the bipartite maximally entangled states with the property that all reduced states of at most half the system size are in the maximally mixed state. AME states are of interest for multipartite teleportation and quantum secret sharing and have recently found new applications in the context of high-energy physics in toy models realizing the AdS/CFT-correspondence. We work out in detail the connection between AME states of minimal support and classical maximum distance separable (MDS) error correcting codes and, in particular, provide explicit closed form expressions for AME states of n parties with local dimension \

  8. Absolute vibrational numbering from isotope shifts in fragmentary spectroscopic data

    Science.gov (United States)

    Pashov, A.; Kowalczyk, P.; Jastrzebski, W.

    2018-05-01

    We discuss application of the isotope effect to establish the absolute vibrational numbering in electronic states of diatomic molecules. This is illustrated by examples of states with potential energy curves of both regular and irregular shape, with one or two potential minima. The minimum number of spectroscopic data (either term values or spectral line positions) necessary to provide a unique numbering is considered. We show that at favourable conditions just four term energies (or spectral lines) in one isotopologue and one term energy in the other suffice.

  9. Absolute photoionization cross-section of the methyl radical.

    Science.gov (United States)

    Taatjes, Craig A; Osborn, David L; Selby, Talitha M; Meloni, Giovanni; Fan, Haiyan; Pratt, Stephen T

    2008-10-02

    The absolute photoionization cross-section of the methyl radical has been measured using two completely independent methods. The CH3 photoionization cross-section was determined relative to that of acetone and methyl vinyl ketone at photon energies of 10.2 and 11.0 eV by using a pulsed laser-photolysis/time-resolved synchrotron photoionization mass spectrometry method. The time-resolved depletion of the acetone or methyl vinyl ketone precursor and the production of methyl radicals following 193 nm photolysis are monitored simultaneously by using time-resolved synchrotron photoionization mass spectrometry. Comparison of the initial methyl signal with the decrease in precursor signal, in combination with previously measured absolute photoionization cross-sections of the precursors, yields the absolute photoionization cross-section of the methyl radical; sigma(CH3)(10.2 eV) = (5.7 +/- 0.9) x 10(-18) cm(2) and sigma(CH3)(11.0 eV) = (6.0 +/- 2.0) x 10(-18) cm(2). The photoionization cross-section for vinyl radical determined by photolysis of methyl vinyl ketone is in good agreement with previous measurements. The methyl radical photoionization cross-section was also independently measured relative to that of the iodine atom by comparison of ionization signals from CH3 and I fragments following 266 nm photolysis of methyl iodide in a molecular-beam ion-imaging apparatus. These measurements gave a cross-section of (5.4 +/- 2.0) x 10(-18) cm(2) at 10.460 eV, (5.5 +/- 2.0) x 10(-18) cm(2) at 10.466 eV, and (4.9 +/- 2.0) x 10(-18) cm(2) at 10.471 eV. The measurements allow relative photoionization efficiency spectra of methyl radical to be placed on an absolute scale and will facilitate quantitative measurements of methyl concentrations by photoionization mass spectrometry.

  10. Absolute X-distribution and self-duality

    OpenAIRE

    Alexandru, Andrei; Horváth, Ivan

    2011-01-01

    Various models of QCD vacuum predict that it is dominated by excitations that are predominantly self-dual or anti-self-dual. In this work we look at the tendency for self-duality in the case of pure-glue SU(3) gauge theory using the overlap-based definition of the field-strength tensor. To gauge this property, we use the absolute X-distribution method which is designed to quantify the dynamical tendency for polarization for arbitrary random variables that can be decomposed in a pair of orthog...

  11. Predicting accurate absolute binding energies in aqueous solution

    DEFF Research Database (Denmark)

    Jensen, Jan Halborg

    2015-01-01

    Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic. In this paper I summarize some of the many factors that could easily contribute 1-3 kcal......-represented by continuum models. While I focus on binding free energies in aqueous solution the approach also applies (with minor adjustments) to any free energy difference such as conformational or reaction free energy differences or activation free energies in any solvent....

  12. Including district heating pipelines in absolute liability laws

    Energy Technology Data Exchange (ETDEWEB)

    Gronau, W

    1977-10-01

    On January 1, 1978 the provisions of the Act Amending the Rules of Liability Damages have entered into force. Formally this means that the provisions of the Reich Liability Act (Reichshaftpflichtgesetz, RHG) and those of the Act on Liability with Respect to Property Damage of Railways and Tramways (SHG) are now combined under the new term of Liability Act (Haftpflichtgesetz). In material terms it means that the district heat industry with its supply pipelines is subject to absolute liability. This creates a liability situation for this industry which has been existing for the electricity and gas industries since 1943 as a result of an amendment of the Reich Liability Act.

  13. Absolute continuity of the distribution of some Markov geometric series

    Institute of Scientific and Technical Information of China (English)

    Ai-hua; FAN; Ji-hong; ZHANG

    2007-01-01

    Let (∈n)≥0 be the Markov chain of two states with respect to the probability measure of the maximal entropy on the subshift space ∑A defined by Fibonacci incident matrix A.We consider the measure μλ of the probability distribution of the random series ∑∞n=0 εnλn (0 <λ< 1).It is proved that μλ is singular if λ∈ (0,√5-1/2) and that μλ is absolutely continuous for almost all λ∈ (√5-1/2,0.739).

  14. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively

  15. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  16. Faraday cup: absolute dosimetry for ELIMED beam line

    International Nuclear Information System (INIS)

    Leanza, R.; Romano, F.; Scuderi, V.; Amico, A.G.; Cuttone, G.; Larosa, G.; Milluzzo, G.; Petringa, G.; Pipek, J.; Cirrone, G.A.P.; Margarone, D.; Schillaci, F.

    2017-01-01

    The scientific community has shown a growing interest towards multidisciplinary applications of laser-driven beams. In this framework, the ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) beamline will be the first transport beamline dedicated to the medical and multidisciplinary studies with laser-accelerated ion beams. Detectors for dosimetry represent one of key-element of the ELIMED beamline, allowing a dose delivering with good result as required in the clinical applications. In this contribution, a Faraday Cup for absolute dosimetry, designed and realized at INFN-LNS, is described.

  17. An Algorithm for Solving the Absolute Value Equation

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří

    2009-01-01

    Roč. 18, - (2009), s. 589-599 E-ISSN 1081-3810 R&D Projects: GA ČR GA201/09/1957; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : absolute value equation * algorithm * regularity * singularity * theorem of the alternatives Subject RIV: BA - General Mathematics Impact factor: 0.892, year: 2009 http://www.math.technion.ac.il/iic/ ela / ela -articles/articles/vol18_pp589-599.pdf

  18. Communication: The absolute shielding scales of oxygen and sulfur revisited

    Energy Technology Data Exchange (ETDEWEB)

    Komorovsky, Stanislav; Repisky, Michal; Malkin, Elena; Ruud, Kenneth, E-mail: kenneth.ruud@uit.no [Centre for Theoretical and Computational Chemistry, University of Tromsø — The Arctic University of Norway, N-9037 Tromsø (Norway); Gauss, Jürgen [Institut für Physikalische Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, D-55128 Mainz (Germany)

    2015-03-07

    We present an updated semi-experimental absolute shielding scale for the {sup 17}O and {sup 33}S nuclei. These new shielding scales are based on accurate rotational microwave data for the spin–rotation constants of H{sub 2}{sup 17}O [Puzzarini et al., J. Chem. Phys. 131, 234304 (2009)], C{sup 17}O [Cazzoli et al., Phys. Chem. Chem. Phys. 4, 3575 (2002)], and H{sub 2}{sup 33}S [Helgaker et al., J. Chem. Phys. 139, 244308 (2013)] corrected both for vibrational and temperature effects estimated at the CCSD(T) level of theory as well as for the relativistic corrections to the relation between the spin–rotation constant and the absolute shielding constant. Our best estimate for the oxygen shielding constants of H{sub 2}{sup 17}O is 328.4(3) ppm and for C{sup 17}O −59.05(59) ppm. The relativistic correction for the sulfur shielding of H{sub 2}{sup 33}S amounts to 3.3%, and the new sulfur shielding constant for this molecule is 742.9(4.6) ppm.

  19. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    International Nuclear Information System (INIS)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron L. C.; Kristensen, Anders

    2014-01-01

    A class of photonic crystal resonant reflectors known as guided mode resonant filters are optical structures that are widely used in the field of refractive index sensing, particularly in biosensing. For the purposes of understanding and design, their behavior has traditionally been modeled numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken into account. Furthermore, it is demonstrated that the model is valid beyond the limit of low grating modulation, for periodically discontinuous waveguide layers, high refractive index contrasts, and highly dispersive media.

  20. DI3 - A New Procedure for Absolute Directional Measurements

    Directory of Open Access Journals (Sweden)

    A Geese

    2011-06-01

    Full Text Available The standard observatory procedure for determining a geomagnetic field's declination and inclination absolutely is the DI-flux measurement. The instrument consists of a non-magnetic theodolite equipped with a single-axis fluxgate magnetometer. Additionally, a scalar magnetometer is needed to provide all three components of the field. Using only 12 measurement steps, all systematic errors can be accounted for, but if only one of the readings is wrong, the whole measurement has to be rejected. We use a three-component sensor on top of the theodolites telescope. By performing more measurement steps, we gain much better control of the whole procedure: As the magnetometer can be fully calibrated by rotating about two independent directions, every combined reading of magnetometer output and theodolite angles provides the absolute field vector. We predefined a set of angle positions that the observer has to try to achieve. To further simplify the measurement procedure, the observer is guided by a pocket pc, in which he has only to confirm the theodolite position. The magnetic field is then stored automatically, together with the horizontal and vertical angles. The DI3 measurement is periodically performed at the Niemegk Observatory, allowing for a direct comparison with the traditional measurements.

  1. Absolute counting of neutrophils in whole blood using flow cytometry.

    Science.gov (United States)

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  2. Achilles: A Homeric hero enamoured with the absolute.

    Science.gov (United States)

    Evzonas, Nicolas

    2017-07-21

    This article explores through a psychoanalytical lens the character of Achilles in Homer's Iliad, the matrix behind the Western conception of heroism. The contribution reveals the psychological link binding the words and acts of the most valiant of warriors in Antiquity, which is situated in myth and termed "the Eros of the absolute." The paroxystic ideality underlying the aforementioned myth, which is rooted in the anthropological need to believe, is at the origin of Achilles' legendary μῆνις, that is, the flood of rage triggered by contests for supremacy, aggravated by the loss of his war comrade, aroused by the drama of aging and death, and then transfigured through song and memory. The main claim of the author is that Iliad, despite its seeming lack of attention to interiority, is launched by the archetypal emotion of wrath and owes its appeal to its hero's embrace of heroic idealism in an excessive, radical and absolute way that results in a captivating narcissism and sadomasochistic antithesis of ideality. This argument leads to the conclusion that Homer is the Father of the "primitive horde" of affects. Copyright © 2017 Institute of Psychoanalysis.

  3. PROFIT AND LOSS ACCOUNT – SYNTHETIC EXPRESSION OF ABSOLUTE RETURN

    Directory of Open Access Journals (Sweden)

    MIRON VASILE CRISTIAN IOACHIM

    2017-08-01

    Full Text Available This study has as main objective the presentation of the current state of knowledge regarding the profit and loss account as part of the financial statements which express in absolute value the profitability of companies and the empirical analysis of these concepts based on the information submitted by OMV Petrom between 2011 and 2015. Thus, in the first part we present several approaches from the specialized literature regarding the aspects mentioned above. The second part follows a vertical and horizontal analysis of key indicators used for measuring the absolute return. For the horizontal analysis we pursued the evolution in time of the following indicators: Gross Margin, Earnings Before Interest and Taxes (EBIT, Financial Result, Gross and Net Result. The vertical analysis aimed to explain the formation of the Gross Result via EBIT (which was also analyzed through the Gross Margin and other specific elements and of the Financial Result (which was also analyzed through the different types of financial income and expenses. The results of the study revealed problems of profitability in the years 2014 and 2015 which, in our opinion, can be attributed to poor management of the commercial activity, exploration activity (research and development, distribution and financial activity.

  4. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  5. Absolute values of neutrino masses: status and prospects

    International Nuclear Information System (INIS)

    Bilenky, S.M.; Giunti, C.; Grifols, J.A.; Masso, E.

    2003-01-01

    Compelling evidences in favor of neutrino masses and mixing obtained in the last years in Super-Kamiokande, SNO, KamLAND and other neutrino experiments made the physics of massive and mixed neutrinos a frontier field of research in particle physics and astrophysics. There are many open problems in this new field. In this review we consider the problem of the absolute values of neutrino masses, which apparently is the most difficult one from the experimental point of view. We discuss the present limits and the future prospects of β-decay neutrino mass measurements and neutrinoless double-β decay. We consider the important problem of the calculation of nuclear matrix elements of neutrinoless double-β decay and discuss the possibility to check the results of different model calculations of the nuclear matrix elements through their comparison with the experimental data. We discuss the upper bound of the total mass of neutrinos that was obtained recently from the data of the 2dF Galaxy Redshift Survey and other cosmological data and we discuss future prospects of the cosmological measurements of the total mass of neutrinos. We discuss also the possibility to obtain information on neutrino masses from the observation of the ultra high-energy cosmic rays (beyond the GZK cutoff). Finally, we review the main aspects of the physics of core-collapse supernovae, the limits on the absolute values of neutrino masses from the observation of SN1987A neutrinos and the future prospects of supernova neutrino detection

  6. Improved Strategies and Optimization of Calibration Models for Real-time PCR Absolute Quantification

    Science.gov (United States)

    Real-time PCR absolute quantification applications rely on the use of standard curves to make estimates of DNA target concentrations in unknown samples. Traditional absolute quantification approaches dictate that a standard curve must accompany each experimental run. However, t...

  7. Characterization of near-infrared nonmetal atomic emission from an atmospheric helium microwave-induced plasma using a Fourier transform spectrophotometer

    International Nuclear Information System (INIS)

    Hubert, J.; Van Tra, H.; Chi Tran, K.; Baudais, F.L.

    1986-01-01

    A new approach for using Fourier transform spectroscopy (FTS) for the detection of atomic emission from an atmospheric helium plasma has been developed and the results obtained are described. Among the different types of plasma source available, the atmospheric pressure microwave helium plasma appears to be an efficient excitation source for the determination of nonmetal species. The more complete microwave plasma emission spectra of Cl, Br, I, S, O, P, C, N, and He in the near-infrared region were obtained and their corrected relative emission intensities are reported. This makes qualitative identification simple, and aids in the quantitative analysis of atomic species. The accuracy of the emission wavelengths obtained with the Fourier transform spectrophotometer was excellent and the resolution provided by the FTS allowed certain adjacent emission lines to be adequate for analytical applications

  8. A new on-axis micro-spectrophotometer for combining Raman, fluorescence and UV/Vis absorption spectroscopy with macromolecular crystallography at the Swiss Light Source.

    Science.gov (United States)

    Pompidor, Guillaume; Dworkowski, Florian S N; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R

    2013-09-01

    The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years.

  9. Aqueous photochemical reactions of chloride, bromide, and iodide ions in a diode-array spectrophotometer. Autoinhibition in the photolysis of iodide ions.

    Science.gov (United States)

    Kalmár, József; Dóka, Éva; Lente, Gábor; Fábián, István

    2014-03-28

    The aqueous photoreactions of three halide ions (chloride, bromide and iodide) were studied using a diode array spectrophotometer to drive and detect the process at the same time. The concentration and pH dependences of the halogen formation rates were studied in detail. The experimental data were interpreted by improving earlier models where the cage complex of a halogen atom and an electron has a central role. The triiodide ion was shown to exert a strong inhibiting effect on the reaction sequence leading to its own formation. An assumed chemical reaction between the triiodide ion and the cage complex interpreted the strong autoinhibition effect. It is shown that there is a real danger of unwanted interference from the photoreactions of halide ions when halide salts are used as supporting electrolytes in spectrophotometric experiments using a relatively high intensity UV light source.

  10. A new on-axis micro-spectrophotometer for combining Raman, fluorescence and UV/Vis absorption spectroscopy with macromolecular crystallography at the Swiss Light Source

    Science.gov (United States)

    Pompidor, Guillaume; Dworkowski, Florian S. N.; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R.

    2013-01-01

    The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years. PMID:23955041

  11. The study of temperature and UV light effect in anthocyanin extract from dragon fruit (Hylocereus costaricensis) rind using UV-Visible spectrophotometer

    Science.gov (United States)

    Purbaningtias, Tri Esti; Aprilia, Anisa Cahyani; Fauzi'ah, Lina

    2017-12-01

    This study aimed to determine the total of anthocyanin content in ethanol extract from super red dragon fruit rind. The extraction was affected by temperature and light conditions. The determination of anthocyanin's total content was performed with a variation of pH and analyzed by UV-Visible spectrophotometer. The results showed that the average contained total anthocyanins obtained at room temperature, 40 and 60 °C were 4.6757, 5.6108, 21.9757 mg/L, respectively. In higher temperatures, it was observed the more anthocyanin extracted. The concentration of anthocyanin extract without UV light was 2.5716 mg/L, it was less than UV light assisted extract, i.e. 5.3770 mg / L.

  12. A spectrophotometer-based diffusivity assay reveals that diffusion hindrance of small molecules in extracellular matrix gels used in 3D cultures is dominated by viscous effects.

    Science.gov (United States)

    Galgoczy, Roland; Pastor, Isabel; Colom, Adai; Giménez, Alicia; Mas, Francesc; Alcaraz, Jordi

    2014-08-01

    The design of 3D culture studies remains challenging due to the limited understanding of extracellular matrix (ECM)-dependent hindered diffusion and the lack of simple diffusivity assays. To address these limitations, we set up a cost-effective diffusivity assay based on a Transwell plate and the spectrophotometer of a Microplate Reader, which are readily accessible to cell biology groups. The spectrophotometer-based assay was used to assess the apparent diffusivity D of FITC-dextrans with molecular weight (4-70kDa) spanning the physiological range of signaling factors in a panel of acellular ECM gels including Matrigel, fibrin and type I collagen. Despite their technical differences, D data exhibited ∼15% relative difference with respect to FRAP measurements. Our results revealed that diffusion hindrance of small particles is controlled by the enhanced viscosity of the ECM gel in conformance with the Stokes-Einstein equation rather than by geometrical factors. Moreover, we provided a strong rationale that the enhanced ECM viscosity is largely contributed to by unassembled ECM macromolecules. We also reported that gels with the lowest D exhibited diffusion hindrance closest to the large physiologic hindrance of brain tissue, which has a typical pore size much smaller than ECM gels. Conversely, sparse gels (≤1mg/ml), which are extensively used in 3D cultures, failed to reproduce the hindered diffusion of tissues, thereby supporting that dense (but not sparse) ECM gels are suitable tissue surrogates in terms of macromolecular transport. Finally, the consequences of reduced diffusivity in terms of optimizing the design of 3D culture experiments were addressed in detail. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Application of the correction's system of bottom by deuterium's lamp of a spectrophotometer of atomic absorption to the obtaining of ultraviolet spectrums

    International Nuclear Information System (INIS)

    Villalobos Chaves, Alberto Enrique

    2002-01-01

    The correction system of bottom by lamp of deuterium's arch of a spectrophotometer of atomic absorption has been utilized with sweep's capacity of wavelength to get spectrums of ultraviolet absorption of samples in gaseous phase, whether in presence as in absence of flame, in the region between 200 nm and 365 nm. The spectral information was obtained after of a process of electronic subtraction of the source's signal, except for the source's signal plus the sample and its subsequent analysis by a programmed data's processor to give a report in terms of wavelength. The spectrums obtained in absence of flame were practiced in samples contained in a gas's sell for infrared spectroscopy with polyethylene's windows, it is located of the burner and directly in front to the radiation's beam, comparable spectrums with the reported in the literature were obtained and with a bigger resolution than the measure with an conventional ultraviolet absorption's spectrophotometer utilized like reference. The spectrums in presence of flame have been of flame have been obtained from dissolved samples and directly suctioned, it achieves to obtain spectral information that is normally not detected conveniently when it performs qualitative analysis by emission of flame in elements such like zinc, lead, cobalt, mercury and nickel among other. The information obtained on this way has been utilized like an alternative method to the elemental analysis by humid way with a view to increase the reliability of the results that have been utilized like basis in the determination of the tariff classification of imported or exported products. (Author) [es

  14. Regional absolute conductivity reconstruction using projected current density in MREIT

    International Nuclear Information System (INIS)

    Sajib, Saurav Z K; Kim, Hyung Joong; Woo, Eung Je; Kwon, Oh In

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a non-invasive technique for imaging the internal conductivity distribution in tissue within an MRI scanner, utilizing the magnetic flux density, which is introduced when a current is injected into the tissue from external electrodes. This magnetic flux alters the MRI signal, so that appropriate reconstruction can provide a map of the additional z-component of the magnetic field (B z ) as well as the internal current density distribution that created it. To extract the internal electrical properties of the subject, including the conductivity and/or the current density distribution, MREIT techniques use the relationship between the external injection current and the z-component of the magnetic flux density B = (B x , B y , B z ). The tissue studied typically contains defective regions, regions with a low MRI signal and/or low MRI signal-to-noise-ratio, due to the low density of nuclear magnetic resonance spins, short T 2 or T* 2 relaxation times, as well as regions with very low electrical conductivity, through which very little current traverses. These defective regions provide noisy B z data, which can severely degrade the overall reconstructed conductivity distribution. Injecting two independent currents through surface electrodes, this paper proposes a new direct method to reconstruct a regional absolute isotropic conductivity distribution in a region of interest (ROI) while avoiding the defective regions. First, the proposed method reconstructs the contrast of conductivity using the transversal J-substitution algorithm, which blocks the propagation of severe accumulated noise from the defective region to the ROI. Second, the proposed method reconstructs the regional projected current density using the relationships between the internal current density, which stems from a current injection on the surface, and the measured B z data. Combining the contrast conductivity distribution in the entire imaging

  15. Absolute luminosity measurement at LHCb with beam-gas imaging

    CERN Document Server

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam-Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used *van der Meer scan* method (VDM). The technique has been used in 10 LHC fills during 2012 including and also provided a first luminosity measurement for proton-lead collisions. This talk presents the principles of the gas injection and the improvements reached with the increased pressure. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch. Those uncertainties are becoming the dominating factor because the uncertainty on the total beam current have been reduced.

  16. ANALISIS ABSOLUTE DAN OBLIQUE DALAM BAHASA KERINCI ISOLEK PULAU TENGAH

    Directory of Open Access Journals (Sweden)

    Nova Rina

    2016-10-01

    Full Text Available This research study in phonological field, aims of this research to discribe rhyme alternation on form of absolute and oblique in Kerinci language isolect pulau tengah. The purpose of this research are 1 to documenting Kerinci language isolect Pulau Tengah that threatened by Indonesian standart, Jakarta Indonesia, Minangkabau language, and most seriously threathened by Kerinci koine 2 the result of this research about description of Kerinci language isolect Pulau Tengah will be useful for other Malayic language researcher especially in remote areas of Sumatera and 3 give langauge contribution significantly for Kerinci society especially for Pulau Tengah society. This research found 19 rhyme alternation in G-words, 20 rhyme alternation in K-words, 16 vocal sequences, 28 consonant clusters, 12 consonant sequences, and base on silable phonotactic rules in Kerinci language isolect Pulau Tengah, it found six rules; V, VC, CV, CVC, CCV, and CCVC.

  17. Absolute dimensions and evolutionary status of UW CMa

    International Nuclear Information System (INIS)

    Parthasarathy, M.

    1978-01-01

    Photoelectric B and V light curves of close binary system UW Canis Majoris (08.5 If + O-B) are analysed. Combining the photoelectric elements and the spectroscopic orbit absolute dimensions of the system are determined. The mass of the bright primary (08.5 If) component is found to be 19.3 solar masses and that of the faint secondary to be 23.2 solar masses. The primary has filled the Roche lobe and it is 1 to 2 mag over-luminous for its mass. The massive secondary component is most likely a main sequence star. Comparison with the theoretical evolutionary models of massive close binary systems undergoing case A of mass exchange indicate that UW CMa is close to the contact stage of evolution. (author)

  18. Moral foundations, worldviews, moral absolutism and belief in conspiracy theories.

    Science.gov (United States)

    Leone, Luigi; Giacomantonio, Mauro; Lauriola, Marco

    2017-09-05

    In the present research, we examined whether individual differences in basic moral concerns might be related to a greater endorsement of conspiracy theories. Building on the notion that conspiracy theories often deal with super-individual relevant events in which a group perspective is central, we proposed that individual differences in moral concerns pertaining to group- and community-concerns (i.e., binding moral foundations) rather than to individual well-being (i.e., individualising moral foundations) would be positively associated with conspiracy beliefs. We further hypothesised that such relations would be totally mediated by beliefs in a dangerous world and by embracing moral absolutism. We found support for these predictions in two community samples (Ns: 319; 514). Theoretical implications were discussed. © 2017 International Union of Psychological Science.

  19. Absolutism versus doceañista liberalism. The Visual Counterattack

    Directory of Open Access Journals (Sweden)

    Carlos Reyero

    2017-09-01

    Full Text Available The aim of this article is to identify some dominants themes within absolutists discourses and to sketch out how they are translated to images, in order to persuade against and to denigrate liberalism. Descriptions of public ornaments in events honoring king Ferdinand VII in 1814 and 1823 are used as the main reference sources. Absolutism is recognized looking for associations between images and words, resemblances, metaphors, symbols and iconographic matches. Visual imagery to achieve absolutist goal emphasized the primacy of the king, the rhetoric of vassalage, a strong motherland, the uniqueness of religion, and the exclusion of the political enemy. In order to totally eliminate the constitutional risk, the tradition was presented as a paradise of peace and happiness.

  20. Absolute Astrometry in the next 50 Years - II

    Science.gov (United States)

    Høg, E.

    2018-01-01

    With the Gaia astrometric satellite in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A space mission with Gaia-like astrometric performance is required, but not necessarily a Gaia-like satellite. A dozen science issues for a Gaia successor mission in twenty years, with launch about 2035, are presented and in this context also other possibilities for absolute astrometry with milliarcsecond (mas) or sub-mas accuracies are discussed in my report at http://arxiv.org/abs/1408.2190. In brief, the two missions (2013 and 2035) would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems, including exo-planet systems with long periods, to compact galaxies, quasars and Dark Matter substructures by data which cannot be surpassed in the next 50 years.

  1. An absolute scale for measuring the utility of money

    Science.gov (United States)

    Thomas, P. J.

    2010-07-01

    Measurement of the utility of money is essential in the insurance industry, for prioritising public spending schemes and for the evaluation of decisions on protection systems in high-hazard industries. Up to this time, however, there has been no universally agreed measure for the utility of money, with many utility functions being in common use. In this paper, we shall derive a single family of utility functions, which have risk-aversion as the only free parameter. The fact that they return a utility of zero at their low, reference datum, either the utility of no money or of one unit of money, irrespective of the value of risk-aversion used, qualifies them to be regarded as absolute scales for the utility of money. Evidence of validation for the concept will be offered based on inferential measurements of risk-aversion, using diverse measurement data.

  2. A SOLAR SPECTROSCOPIC ABSOLUTE ABUNDANCE OF ARGON FROM RESIK

    International Nuclear Information System (INIS)

    Sylwester, J.; Sylwester, B.; Phillips, K. J. H.; Kuznetsov, V. D.

    2010-01-01

    Observations of He-like and H-like Ar (Ar XVII and Ar XVIII) lines at 3.949 A and 3.733 A, respectively, with the RESIK X-ray spectrometer on the CORONAS-F spacecraft, together with temperatures and emission measures from the two channels of GOES, have been analyzed to obtain the abundance of Ar in flare plasmas in the solar corona. The line fluxes per unit emission measure show a temperature dependence like that predicted from theory and lead to spectroscopically determined values for the absolute Ar abundance, A(Ar) = 6.44 ± 0.07 (Ar XVII) and 6.49 ± 0.16 (Ar XVIII), which are in agreement to within uncertainties. The weighted mean is 6.45 ± 0.06, which is between two recent compilations of the solar Ar abundance and suggests that the photospheric and coronal abundances of Ar are very similar.

  3. Ensuring long-term stability of infrared camera absolute calibration.

    Science.gov (United States)

    Kattnig, Alain; Thetas, Sophie; Primot, Jérôme

    2015-07-13

    Absolute calibration of cryogenic 3-5 µm and 8-10 µm infrared cameras is notoriously instable and thus has to be repeated before actual measurements. Moreover, the signal to noise ratio of the imagery is lowered, decreasing its quality. These performances degradations strongly lessen the suitability of Infrared Imaging. These defaults are often blamed on detectors reaching a different "response state" after each return to cryogenic conditions, while accounting for the detrimental effects of imperfect stray light management. We show here that detectors are not to be blamed and that the culprit can also dwell in proximity electronics. We identify an unexpected source of instability in the initial voltage of the integrating capacity of detectors. Then we show that this parameter can be easily measured and taken into account. This way we demonstrate that a one month old calibration of a 3-5 µm camera has retained its validity.

  4. Absolute measurement of undulator radiation in the extreme ultraviolet

    International Nuclear Information System (INIS)

    Maezawa, H.; Kitamura, H.; Sasaki, T.; Mitani, S.; Osaka City Univ.; Suzuki, Y.; Kanamori, H.; Tamamushi, S.; Tokyo Univ.; Mikuni, A.; Tokyo Univ., Tanashi

    1983-01-01

    The spectral brightness of undulator radiation emitted by the model PMU-1 incorporated in the SOR-RING, the dedicated synchrotron radiation source in Tokyo, has been studied in the extreme ultraviolet region from 21.6 to 72.9 eV as a function of the electron energy #betta#, the field parameter K, and the angle of observation THETA in the absolute scale. A series of measurements covering the first and the second harmonic component of undulator radiation was compared with the fundamental formula lambdasub(n)=lambda 0 /2n#betta# 2 (1+K 2 /2+#betta# 2 THETA 2 ), and the effects of finite emittance were studied. The brightness at the first peak was smaller than the theoretical value, while an enhanced second harmonic component was observed. (orig.)

  5. Absolute measurement of the critical scattering cross section in cobalt

    International Nuclear Information System (INIS)

    Glinka, C.J.; Minkiewicz, V.J.; Passell, L.

    1975-01-01

    Small-angle neutron scattering techniques have been used to study the angular distribution of the critical scattering from cobalt above T/sub c/. These measurements have been put on an absolute scale by calibrating the critical scattering directly against the nuclear incoherent scattering from cobalt. In this way the interaction range r 1 , which appears in the classical and modified Ornstein--Zernike expressions for the asymptotic form of the spin pair correlation function and is related to the strength of the spin correlations, has been determined. We obtain r 1 /a = 0.46 +- 0.03 for the ratio of the interaction range to the nearest-neighbor distance in cobalt. This result is in good agreement with theoretical predictions. Lack of agreement among previous determinations of the ratio r 1 /a made in iron failed to provide a definitive comparison with theory

  6. A three-axis SQUID-based absolute vector magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Schönau, T.; Schmelz, M.; Stolz, R.; Anders, S.; Linzen, S.; Meyer, H.-G. [Department of Quantum Detection, Leibniz Institute of Photonic Technology, Jena 07745 (Germany); Zakosarenko, V.; Meyer, M. [Supracon AG, An der Lehmgrube 11, Jena 07751 (Germany)

    2015-10-15

    We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

  7. First derivative versus absolute spectral reflectance of citrus varieties

    Science.gov (United States)

    Blazquez, Carlos H.; Nigg, H. N.; Hedley, Lou E.; Ramos, L. E.; Sorrell, R. W.; Simpson, S. E.

    1996-06-01

    Spectral reflectance measurements from 400 to 800 nm were taken from immature and mature leaves of grapefruit ('McCarty' and 'Rio Red'), 'Minneola' tangelo, 'Satsuma' mandarin, 'Dancy' tangerine, 'Nagami' oval kumquat, and 'Valencia' sweet orange, at the Florida Citrus Arboretum, Division of Plant Industry, Winter Haven, Florida. Immature and mature leaves of 'Minneola' tangelo had greater percent reflectance in the 400 to 800 nm range than the other varieties and leaf ages measured. The slope of the citrus spectral curves in the 800 nm range was not as sharp as conventional spectrometers, but had a much higher reflectance value than those obtained with a DK-2 spectrometer. Statistical analyses of absolute spectral data yielded significant differences between mature and immature leaves and between varieties. First derivative data analyses did not yield significant differences between varieties.

  8. Absolute dimensions and masses of eclipsing binaries. V. IQ Persei

    International Nuclear Information System (INIS)

    Lacy, C.H.; Frueh, M.L.; McDonald Observatory, Austin)

    1985-01-01

    New photometric and spectroscopic observations of the 1.7 day eclipsing binary IQ Persei (B8 + A6) have been analyzed to yield very accurate fundamental properties of the system. Reticon spectroscopic observations obtained at McDonald Observatory were used to determine accurate radial velocities of both stars in this slightly eccentric large light-ratio binary. A new set of VR light curves obtained at McDonald Observatory were analyzed by synthesis techniques, and previously published UBV light curves were reanalyzed to yield accurate photometric orbits. Orbital parameters derived from both sets of photometric observations are in excellent agreement. The absolute dimensions, masses, luminosities, and apsidal motion period (140 yr) derived from these observations agree well with the predictions of theoretical stellar evolution models. The A6 secondary is still very close to the zero-age main sequence. The B8 primary is about one-third of the way through its main-sequence evolution. 27 references

  9. Sub-nanometer periodic nonlinearity error in absolute distance interferometers

    Science.gov (United States)

    Yang, Hongxing; Huang, Kaiqi; Hu, Pengcheng; Zhu, Pengfei; Tan, Jiubin; Fan, Zhigang

    2015-05-01

    Periodic nonlinearity which can result in error in nanometer scale has become a main problem limiting the absolute distance measurement accuracy. In order to eliminate this error, a new integrated interferometer with non-polarizing beam splitter is developed. This leads to disappearing of the frequency and/or polarization mixing. Furthermore, a strict requirement on the laser source polarization is highly reduced. By combining retro-reflector and angel prism, reference and measuring beams can be spatially separated, and therefore, their optical paths are not overlapped. So, the main cause of the periodic nonlinearity error, i.e., the frequency and/or polarization mixing and leakage of beam, is eliminated. Experimental results indicate that the periodic phase error is kept within 0.0018°.

  10. Absolute cross-section measurements of inner-shell ionization

    Science.gov (United States)

    Schneider, Hans; Tobehn, Ingo; Ebel, Frank; Hippler, Rainer

    1994-12-01

    Cross section ratios for K- and L-shell ionization of thin silver and gold targets by positron and electron impact have been determined at projectile energies of 30 70 keV. The experimental results are confirmed by calculations in plane wave Born approximation (PWBA) which include an electron exchange term and account for the deceleration or acceleration of the incident projectile in the nuclear field of the target atom. We report first absolute cross sections for K- and L-shell ionization of silver and gold targets by lepton impact in the threshold region. We have measured the corresponding cross sections for electron (e-) impact with an electron gun and the same experimental set-up.

  11. Cosmic backgrounds of relic gravitons and their absolute normalization

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    Provided the consistency relations are not violated, the recent Bicep2 observations pin down the absolute normalization, the spectral slope and the maximal frequency of the cosmic graviton background produced during inflation. The properly normalized spectra are hereby computed from the lowest frequencies (of the order of the present Hubble rate) up to the highest frequency range in the GHz region. Deviations from the conventional paradigm cannot be excluded and are examined by allowing for different physical possibilities including, in particular, a running of the tensor spectral index, an explicit breaking of the consistency relations and a spike in the high-frequency tail of the spectrum coming either from a post-inflationary phase dominated by a stiff fluid of from the contribution of waterfall fields in a hybrid inflationary context. The direct determinations of the tensor to scalar ratio at low frequencies, if confirmed by the forthcoming observations, will also affect and constrain the high-frequencies...

  12. Absolute negative mobility induced by white Poissonian noise

    International Nuclear Information System (INIS)

    Spiechowicz, J; Łuczka, J; Hänggi, P

    2013-01-01

    We study the transport properties of inertial Brownian particles which move in a symmetric periodic potential and are subjected to both a symmetric, unbiased time-periodic external force and a biased Poissonian white shot noise (of non-zero average F) which is composed of a random sequence of δ-shaped pulses with random amplitudes. Upon varying the parameters of the white shot noise, one can conveniently manipulate the transport direction and the overall nonlinear response behavior. We find that within tailored parameter regimes the response is opposite to the applied average bias F of such white shot noise. This particular transport characteristic thus mimics that of a nonlinear absolute negative mobility (ANM) regime. Moreover, such white shot noise driven ANM is robust with respect to the statistics of the shot noise spikes. Our findings can be checked and corroborated experimentally by the use of a setup that consists of a single resistively and capacitively shunted Josephson junction device. (paper)

  13. The Absolute Reflectance and New Calibration Site of the Moon

    Science.gov (United States)

    Wu, Yunzhao; Wang, Zhenchao; Cai, Wei; Lu, Yu

    2018-05-01

    How bright the Moon is forms a simple but fundamental and important question. Although numerous efforts have been made to answer this question such as use of sophisticated electro-optical measurements and suggestions for calibration sites, the answer is still debated. An in situ measurement with a calibration panel on the surface of the Moon is crucial for obtaining the accurate absolute reflectance and resolving the debate. China’s Chang’E-3 (CE-3) “Yutu” rover accomplished this type of measurement using the Visible-Near Infrared Spectrometer (VNIS). The measurements of the VNIS, which were at large emission and phase angles, complement existing measurements for the range of photometric geometry. The in situ reflectance shows that the CE-3 landing site is very dark with an average reflectance of 3.86% in the visible bands. The results are compared with recent mission instruments: the Lunar Reconnaissance Orbiter Camera (LROC) Wide Angle Camera (WAC), the Spectral Profiler (SP) on board the SELENE, the Moon Mineralogy Mapper (M3) on board the Chandrayaan-1, and the Chang’E-1 Interference Imaging Spectrometer (IIM). The differences in the measurements of these instruments are very large and indicate inherent differences in their absolute calibration. The M3 and IIM measurements are smaller than LROC WAC and SP, and the VNIS measurement falls between these two pairs. When using the Moon as a radiance source for the on-orbit calibration of spacecraft instruments, one should be cautious about the data. We propose that the CE-3 landing site, a young and homogeneous surface, should serve as the new calibration site.

  14. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Reda, Ibrahim M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dooraghi, Michael R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Grobner, Julian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Thomann, Christian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Long, Chuck [National Oceanic and Atmospheric Administration; McComiskey, Allison [National Oceanic and Atmospheric Administration; Hall, Emiel [National Oceanic and Atmospheric Administration; Wacker, Stefan [Deutscher Wetterdienst

    2018-03-05

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

  15. Cylindrical Taylor states conserving total absolute magnetic helicity

    Science.gov (United States)

    Low, B. C.; Fang, F.

    2014-09-01

    The Taylor state of a three-dimensional (3D) magnetic field in an upright cylindrical domain V is derived from first principles as an extremum of the total magnetic energy subject to a conserved, total absolute helicity Habs. This new helicity [Low, Phys. Plasmas 18, 052901 (2011)] is distinct from the well known classical total helicity and relative total helicity in common use to describe wholly-contained and anchored fields, respectively. A given field B, tangential along the cylindrical side of V, may be represented as a unique linear superposition of two flux systems, an axially extended system along V and a strictly transverse system carrying information on field-circulation. This specialized Chandrasekhar-Kendall representation defines Habs and permits a neat formulation of the boundary-value problem (BVP) for the Taylor state as a constant-α force-free field, treating 3D wholly-contained and anchored fields on the same conceptual basis. In this formulation, the governing equation is a scalar integro-partial differential equation (PDE). A family of series solutions for an anchored field is presented as an illustration of this class of BVPs. Past treatments of the constant-α field in 3D cylindrical geometry are based on a scalar Helmholtz PDE as the governing equation, with issues of inconsistency in the published field solutions discussed over time in the journal literature. The constant-α force-free equation reduces to a scalar Helmholtz PDE only as special cases of the 3D integro-PDE derived here. In contrast, the constant-α force-free equation and the scalar Helmholtz PDE are absolutely equivalent in the spherical domain as discussed in Appendix. This theoretical study is motivated by the investigation of the Sun's corona but the results are also relevant to laboratory plasmas.

  16. THE ABSOLUTE MAGNITUDE OF RRc VARIABLES FROM STATISTICAL PARALLAX

    International Nuclear Information System (INIS)

    Kollmeier, Juna A.; Burns, Christopher R.; Thompson, Ian B.; Preston, George W.; Crane, Jeffrey D.; Madore, Barry F.; Morrell, Nidia; Prieto, José L.; Shectman, Stephen; Simon, Joshua D.; Villanueva, Edward; Szczygieł, Dorota M.; Gould, Andrew; Sneden, Christopher; Dong, Subo

    2013-01-01

    We present the first definitive measurement of the absolute magnitude of RR Lyrae c-type variable stars (RRc) determined purely from statistical parallax. We use a sample of 242 RRc variables selected from the All Sky Automated Survey for which high-quality light curves, photometry, and proper motions are available. We obtain high-resolution echelle spectra for these objects to determine radial velocities and abundances as part of the Carnegie RR Lyrae Survey. We find that M V,RRc = 0.59 ± 0.10 at a mean metallicity of [Fe/H] = –1.59. This is to be compared with previous estimates for RRab stars (M V,RRab = 0.76 ± 0.12) and the only direct measurement of an RRc absolute magnitude (RZ Cephei, M V,RRc = 0.27 ± 0.17). We find the bulk velocity of the halo relative to the Sun to be (W π , W θ , W z ) = (12.0, –209.9, 3.0) km s –1 in the radial, rotational, and vertical directions with dispersions (σ W π ,σ W θ ,σ W z ) = (150.4, 106.1, 96.0) km s -1 . For the disk, we find (W π , W θ , W z ) = (13.0, –42.0, –27.3) km s –1 relative to the Sun with dispersions (σ W π ,σ W θ ,σ W z ) = (67.7,59.2,54.9) km s -1 . Finally, as a byproduct of our statistical framework, we are able to demonstrate that UCAC2 proper-motion errors are significantly overestimated as verified by UCAC4

  17. Regional and site-specific absolute humidity data for use in tritium dose calculations

    International Nuclear Information System (INIS)

    Etnier, E.L.

    1980-01-01

    Due to the potential variability in average absolute humidity over the continental U.S., and the dependence of atmospheric 3 H specific activity on absolute humidity, availability of regional absolute humidity data is of value in estimating the radiological significance of 3 H releases. Most climatological data are in the form of relative humidity, which must be converted to absolute humidity for dose calculations. Absolute humidity was calculated for 218 points across the U.S., using the 1977 annual summary of U.S. Climatological Data, and is given in a table. Mean regional values are shown on a map. (author)

  18. Agreement between digital image analysis and clinical spectrophotometer in CIEL*C*h° coordinate differences and total color difference (ΔE) measurements of dental ceramic shade tabs.

    Science.gov (United States)

    Farah, Ra'fat I

    2016-01-01

    The objectives of this in vitro study were: 1) to test the agreement among color coordinate differences and total color difference (ΔL*, ΔC*, Δh°, and ΔE) measurements obtained by digital image analysis (DIA) and spectrophotometer, and 2) to test the reliability of each method for obtaining color differences. A digital camera was used to record standardized images of each of the 15 shade tabs from the IPS e.max shade guide placed edge-to-edge in a phantom head with a reference shade tab. The images were analyzed using image-editing software (Adobe Photoshop) to obtain the color differences between the middle area of each test shade tab and the corresponding area of the reference tab. The color differences for the same shade tab areas were also measured using a spectrophotometer. To assess the reliability, measurements for the 15 shade tabs were repeated twice using the two methods. The Intraclass Correlation Coefficient (ICC) and the Dahlberg index were used to calculate agreement and reliability. The total agreement of the two methods for measuring ΔL*, ΔC*, Δh°, and ΔE, according to the ICC, exceeded 0.82. The Dahlberg indices for ΔL* and ΔE were 2.18 and 2.98, respectively. For the reliability calculation, the ICCs for the DIA and the spectrophotometer ΔE were 0.91 and 0.94, respectively. High agreement was obtained between the DIA and spectrophotometer results for the ΔL*, ΔC*, Δh°, and ΔE measurements. Further, the reliability of the measurements for the spectrophotometer was slightly higher than the reliability of all measurements in the DIA.

  19. An Absolute Valve for the ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Jones, Ch.; Chuilon, B.; Michael, W.

    2006-01-01

    In the ITER reference design a fast shutter was included to limit tritium migration into the beamline vacuum enclosures. The need was recently identified to extend the functionality of the fast shutter to that of an absolute valve in order to facilitate injector maintenance procedures and to satisfy safety requirements in case of an in-vessel loss of coolant event. Three concepts have been examined satisfying the ITER requirements for speed of actuation, sealing performance over the required lifetime, and pressure differential in fault scenarios, namely: a rectangular closure section; a circular cross section; and a rotary JET-type valve. The rectangular section represents the most efficient usage of the available space envelope and leads to a minimum-mass system, although it requires greater total force for a given load per unit length of seal. However, a metallic seal of the '' hard/hard '' type, where the seal relies on the elastic properties of the material and does not utilise any type of spring device, can provide the required seal performance with typical loading of 200 kg/cm. The conceptual design of the proposed absolute valve will be presented. The aperture dimensions are 1.45 m high by 0.6 m wide, with minimum achievable leak rate of 1 · 10 -9 mbarl/s and maximum pressure differential of 3 bar across the valve. Sealing force is provided using two seal plates, linked by a 3 mm thick ' omega ' diaphragm, by pressurisation of the interspace to 8 bar; this allows for a relative movement of the plates of 2 mm. Movement of the device perpendicular to the beam direction is carried out using a novel magnetic drive in order to transmit the motive force across the vacuum boundary, similar to that demonstrated on a test-rig in an earlier study. The conceptual design includes provision of all the services such as pneumatics and water cooling to cope with the heat loads from neutral beams in quasi steady-state operation and from the ITER plasma. A future programme

  20. THE ABSOLUTE MAGNITUDE OF RRc VARIABLES FROM STATISTICAL PARALLAX

    Energy Technology Data Exchange (ETDEWEB)

    Kollmeier, Juna A.; Burns, Christopher R.; Thompson, Ian B.; Preston, George W.; Crane, Jeffrey D.; Madore, Barry F.; Morrell, Nidia; Prieto, José L.; Shectman, Stephen; Simon, Joshua D.; Villanueva, Edward [Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Szczygieł, Dorota M.; Gould, Andrew [Department of Astronomy, The Ohio State University, 4051 McPherson Laboratory, Columbus, OH 43210 (United States); Sneden, Christopher [Department of Astronomy, University of Texas at Austin, TX 78712 (United States); Dong, Subo [Institute for Advanced Study, 500 Einstein Drive, Princeton, NJ 08540 (United States)

    2013-09-20

    We present the first definitive measurement of the absolute magnitude of RR Lyrae c-type variable stars (RRc) determined purely from statistical parallax. We use a sample of 242 RRc variables selected from the All Sky Automated Survey for which high-quality light curves, photometry, and proper motions are available. We obtain high-resolution echelle spectra for these objects to determine radial velocities and abundances as part of the Carnegie RR Lyrae Survey. We find that M{sub V,RRc} = 0.59 ± 0.10 at a mean metallicity of [Fe/H] = –1.59. This is to be compared with previous estimates for RRab stars (M{sub V,RRab} = 0.76 ± 0.12) and the only direct measurement of an RRc absolute magnitude (RZ Cephei, M{sub V,RRc} = 0.27 ± 0.17). We find the bulk velocity of the halo relative to the Sun to be (W{sub π}, W{sub θ}, W{sub z} ) = (12.0, –209.9, 3.0) km s{sup –1} in the radial, rotational, and vertical directions with dispersions (σ{sub W{sub π}},σ{sub W{sub θ}},σ{sub W{sub z}}) = (150.4, 106.1, 96.0) km s{sup -1}. For the disk, we find (W{sub π}, W{sub θ}, W{sub z} ) = (13.0, –42.0, –27.3) km s{sup –1} relative to the Sun with dispersions (σ{sub W{sub π}},σ{sub W{sub θ}},σ{sub W{sub z}}) = (67.7,59.2,54.9) km s{sup -1}. Finally, as a byproduct of our statistical framework, we are able to demonstrate that UCAC2 proper-motion errors are significantly overestimated as verified by UCAC4.

  1. Absolute Thermal SST Measurements over the Deepwater Horizon Oil Spill

    Science.gov (United States)

    Good, W. S.; Warden, R.; Kaptchen, P. F.; Finch, T.; Emery, W. J.

    2010-12-01

    Climate monitoring and natural disaster rapid assessment require baseline measurements that can be tracked over time to distinguish anthropogenic versus natural changes to the Earth system. Disasters like the Deepwater Horizon Oil Spill require constant monitoring to assess the potential environmental and economic impacts. Absolute calibration and validation of Earth-observing sensors is needed to allow for comparison of temporally separated data sets and provide accurate information to policy makers. The Ball Experimental Sea Surface Temperature (BESST) radiometer was designed and built by Ball Aerospace to provide a well calibrated measure of sea surface temperature (SST) from an unmanned aerial system (UAS). Currently, emissive skin SST observed by satellite infrared radiometers is validated by shipborne instruments that are expensive to deploy and can only take a few data samples along the ship track to overlap within a single satellite pixel. Implementation on a UAS will allow BESST to map the full footprint of a satellite pixel and perform averaging to remove any local variability due to the difference in footprint size of the instruments. It also enables the capability to study this sub-pixel variability to determine if smaller scale effects need to be accounted for in models to improve forecasting of ocean events. In addition to satellite sensor validation, BESST can distinguish meter scale variations in SST which could be used to remotely monitor and assess thermal pollution in rivers and coastal areas as well as study diurnal and seasonal changes to bodies of water that impact the ocean ecosystem. BESST was recently deployed on a conventional Twin Otter airplane for measurements over the Gulf of Mexico to access the thermal properties of the ocean surface being affected by the oil spill. Results of these measurements will be presented along with ancillary sensor data used to eliminate false signals including UV and Synthetic Aperture Radar (SAR

  2. Athermal fiber laser for the SWARM absolute scalar magnetometer

    Science.gov (United States)

    Fourcault, W.; Léger, J.-M.; Costes, V.; Fratter, I.; Mondin, L.

    2017-11-01

    The Absolute Scalar Magnetometer (ASM) developed by CEA-LETI/CNES is an optically pumped 4He magnetic field sensor based on the Zeeman effect and an electronic magnetic resonance whose effects are amplified by a laser pumping process [1-2]. Consequently, the role of the laser is to pump the 4He atoms at the D0 transition as well as to allow the magnetic resonance signal detection. The ASM will be the scalar magnetic reference instrument of the three ESA Swarm satellites to be launched in 2012 in order to carry out the best ever survey of the Earth magnetic field and its temporal evolution. The sensitivity and accuracy of this magnetometer based on 4He optical pumping depend directly on the characteristics of its light source, which is the key sub-system of the sensor. We describe in this paper the selected fiber laser architecture and its wavelength stabilization scheme. Its main performance in terms of spectral emission, optical power at 1083 nm and intensity noise characteristics in the frequency bands used for the operation of the magnetometer, are then presented. Environmental testing results (thermal vacuum cycling, vibrations, shocks and ageing) are also reported at the end of this paper.

  3. Absolute Dimensions of Contact Binary Stars in Baade Window

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    1999-12-01

    Full Text Available The light curves of the representative 6 contact binary stars observed by OGLE Project of searching for dark matter in our Galaxy have been analyzed by the method of the Wilson and Devinney Differential Correction to find photometric solutions. The orbital inclinations of these binaries are in the range of 52 deg - 69 deg which is lower than that of the solar neighborhood binaries. The Roche lobe filling factor of these binaries are distributed in large range of 0.12 - 0.90. Since absence of spectroscopic observations for these binaries we have found masses of the 6 binary systems based on the intersection between Kepler locus and locus derived from Vandenberg isochrones in the mass - luminosity plane. Then absolute dimensions and distances have been found by combining the masses and the photometric solutions. The distances of the 6 binary systems are distributed in the range of 1 kpc - 6 kpc. This distance range is the limiting range where the contact binaries which have period shorter than a day are visible. Most contact binaries discovered in the Baade window do not belong to the Galactic bulge.

  4. Absolute measurement of neutron fluxes inside the reactor core

    International Nuclear Information System (INIS)

    Ajdacic, S. V.

    1964-10-01

    The subject of this work is the development and study of two methods of neutron measurements in nuclear reactors, the new method of high neutron flux measurements and the Li 6 -semiconductor neutron spectrometer. This work is presented in four sections: Section I. The introduction explains the need for neutron measurements in reactors. A critical survey is given of the existing methods of high neutron flux measurement and methods of fast neutron spectrum determination. Section II. Theoretical basis of the work of semiconductor counters and their most important characteristics are given. Section III. The main point of this section is in presenting the basis of the new method which the author developed, i.e., the long-tube method, and the results obtained by it, with particular emphasis on absolute measurement of high neutron fluxes. Advantages and limitations of this method are discussed in details at the end of this section. Section IV. A comparison of the existing semiconductor neutron spectrometers is made and their advantages and shortcomings underlined. A critical analysis of the obtained results with the Li 6 -semiconductor spectrometer with plane geometry is given. A new type of Li 6 -semiconductor spectrometer is described, its characteristics experimentally determined, and a comparison of it with a classical Li 6 -spectrometer made (author)

  5. Praising the Ruler: Panegyrical Poetry and Russian Absolutism

    Directory of Open Access Journals (Sweden)

    Joachim Klein

    2015-12-01

    Full Text Available It is difficult to overrate the importance of the panegyric tradition for early modern Russian literature. Between the middle of the 17th to the end of the 18th century, it was practiced in many different genres—almost all Russian poets praised the ruler. This poetry deserves our interest as a specific form of political literature. As such it is not only relevant for the cult of the Russian monarchs, but it also sheds some light on the political mentality of their loyal—and literate—subjects in the age of Russian absolutism. Panegyrical poetry is per definitionem a thoroughly affirmative, noncritical form of political literature. But this did not prevent it from offering a certain scope for the expression of diverse and even contradictory political ideals. This can be exemplified by the panegyrical poems written in the early 1760s in the context of the coup d’état staged by Catherine II and against the backdrop of the Russo-Prussian peace treaty initiated by her predecessor, Peter III. In this situation, a fundamental difference of opinion about the tasks of the monarch and the mission of the Russian state emerged.

  6. Estimation of Cumulative Absolute Velocity using Empirical Green's Function Method

    International Nuclear Information System (INIS)

    Park, Dong Hee; Yun, Kwan Hee; Chang, Chun Joong; Park, Se Moon

    2009-01-01

    In recognition of the needs to develop a new criterion for determining when the OBE (Operating Basis Earthquake) has been exceeded at nuclear power plants, Cumulative Absolute Velocity (CAV) was introduced by EPRI. The concept of CAV is the area accumulation with the values more than 0.025g occurred during every one second. The equation of the CAV is as follows. CAV = ∫ 0 max |a(t)|dt (1) t max = duration of record, a(t) = acceleration (>0.025g) Currently, the OBE exceedance criteria in Korea is Peak Ground Acceleration (PGA, PGA>0.1g). When Odesan earthquake (M L =4.8, January 20th, 2007) and Gyeongju earthquake (M L =3.4, June 2nd, 1999) were occurred, we have had already experiences of PGA greater than 0.1g that did not even cause any damage to the poorly-designed structures nearby. This moderate earthquake has motivated Korea to begin the use of the CAV for OBE exceedance criteria for NPPs. Because the present OBE level has proved itself to be a poor indicator for small-to-moderate earthquakes, for which the low OBE level can cause an inappropriate shut down the plant. A more serious possibility is that this scenario will become a reality at a very high level. Empirical Green's Function method was a simulation technique which can estimate the CAV value and it is hereby introduced

  7. An Absolute Phase Space for the Physicality of Matter

    International Nuclear Information System (INIS)

    Valentine, John S.

    2010-01-01

    We define an abstract and absolute phase space (''APS'') for sub-quantum intrinsic wave states, in three axes, each mapping directly to a duality having fundamental ontological basis. Many aspects of quantum physics emerge from the interaction algebra and a model deduced from principles of 'unique solvability' and 'identifiable entity', and we reconstruct previously abstract fundamental principles and phenomena from these new foundations. The physical model defines bosons as virtual continuous waves pairs in the APS, and fermions as real self-quantizing snapshots of those waves when simple conditions are met. The abstraction and physical model define a template for the constitution of all fermions, a template for all the standard fundamental bosons and their local interactions, in a common framework and compactified phase space for all forms of real matter and virtual vacuum energy, and a distinct algebra for observables and unobservables. To illustrate our scheme's potential, we provide examples of slit experiment variations (where the model finds theoretical basis for interference only occurring between two final sources), QCD (where we may model most attributes known to QCD, and a new view on entanglement), and we suggest approaches for other varied applications. We believe this is a viable candidate for further exploration as a foundational proposition for physics.

  8. Characterization of a digital camera as an absolute tristimulus colorimeter

    Science.gov (United States)

    Martinez-Verdu, Francisco; Pujol, Jaume; Vilaseca, Meritxell; Capilla, Pascual

    2003-01-01

    An algorithm is proposed for the spectral and colorimetric characterization of digital still cameras (DSC) which allows to use them as tele-colorimeters with CIE-XYZ color output, in cd/m2. The spectral characterization consists of the calculation of the color-matching functions from the previously measured spectral sensitivities. The colorimetric characterization consists of transforming the RGB digital data into absolute tristimulus values CIE-XYZ (in cd/m2) under variable and unknown spectroradiometric conditions. Thus, at the first stage, a gray balance has been applied over the RGB digital data to convert them into RGB relative colorimetric values. At a second stage, an algorithm of luminance adaptation vs. lens aperture has been inserted in the basic colorimetric profile. Capturing the ColorChecker chart under different light sources, the DSC color analysis accuracy indexes, both in a raw state and with the corrections from a linear model of color correction, have been evaluated using the Pointer'86 color reproduction index with the unrelated Hunt'91 color appearance model. The results indicate that our digital image capture device, in raw performance, lightens and desaturates the colors.

  9. Targeting LDL Cholesterol: Beyond Absolute Goals Toward Personalized Risk.

    Science.gov (United States)

    Leibowitz, Morton; Cohen-Stavi, Chandra; Basu, Sanjay; Balicer, Ran D

    2017-06-01

    The aim of this study was to review and assess the evidence for low-density lipoprotein cholesterol (LDL-C) treatment goals as presented in current guidelines for primary and secondary prevention of cardiovascular disease. Different sets of guidelines and clinical studies for secondary prevention have centered on lower absolute LDL-C targets [achieve greater reductions in cardiovascular risk. Population-based risk models serve as the basis for statin initiation in primary prevention. Reviews of current population risk models for primary prevention show moderate ability to discriminate [with c-statistics ranging from 0.67 to 0.77 (95% CIs from 0.62 to 0.83) for men and women] with poor calibration and overestimation of risk. Individual clinical trial data are not compelling to support specific LDL-C targets and percent reductions in secondary prevention. Increasing utilization of electronic health records and data analytics will enable the development of individualized treatment goals in both primary and secondary prevention.

  10. ATLAS ALFA—measuring absolute luminosity with scintillating fibres

    CERN Document Server

    Franz, S

    2009-01-01

    ALFA is a high-precision scintillating fibre tracking detector under construction for the absolute determination of the LHC luminosity at the ATLAS interaction point. This detector, mounted in so-called Roman Pots, will track protons elastically scattered under μrad angles at IP1.In total there are four pairs of vertically arranged detector modules which approach the LHC beam axis to mm distance. Each detector module consists of ten layers of two times 64 scintillating fibres each (U and V planes). The fibres are coupled to 64 channels Multi-Anodes PhotoMultipliers Tubes read out by compact front-end electronics. Each detector module is complemented by so-called overlap detectors: Three layers of two times 30 scintillating fibres which will be used to measure the relative positioning of two vertically arranged main detectors. The total number of channels is about 15000. Conventional plastic scintillator tiles are mounted in front of the fibre detectors and will serve as trigger counter. The extremely restric...

  11. Absolute measurement of neutron fluxes inside the reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Ajdacic, S V [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1964-10-15

    The subject of this work is the development and study of two methods of neutron measurements in nuclear reactors, the new method of high neutron flux measurements and the Li{sup 6}-semiconductor neutron spectrometer. This work is presented in four sections: Section I. The introduction explains the need for neutron measurements in reactors. A critical survey is given of the existing methods of high neutron flux measurement and methods of fast neutron spectrum determination. Section II. Theoretical basis of the work of semiconductor counters and their most important characteristics are given. Section III. The main point of this section is in presenting the basis of the new method which the author developed, i.e., the long-tube method, and the results obtained by it, with particular emphasis on absolute measurement of high neutron fluxes. Advantages and limitations of this method are discussed in details at the end of this section. Section IV. A comparison of the existing semiconductor neutron spectrometers is made and their advantages and shortcomings underlined. A critical analysis of the obtained results with the Li{sup 6}-semiconductor spectrometer with plane geometry is given. A new type of Li{sup 6}-semiconductor spectrometer is described, its characteristics experimentally determined, and a comparison of it with a classical Li{sup 6}-spectrometer made (author)

  12. An absolute calibration system for millimeter-accuracy APOLLO measurements

    Science.gov (United States)

    Adelberger, E. G.; Battat, J. B. R.; Birkmeier, K. J.; Colmenares, N. R.; Davis, R.; Hoyle, C. D.; Huang, L. R.; McMillan, R. J.; Murphy, T. W., Jr.; Schlerman, E.; Skrobol, C.; Stubbs, C. W.; Zach, A.

    2017-12-01

    Lunar laser ranging provides a number of leading experimental tests of gravitation—important in our quest to unify general relativity and the standard model of physics. The apache point observatory lunar laser-ranging operation (APOLLO) has for years achieved median range precision at the  ∼2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in situ. The system consists of a high-repetition-rate (80 MHz) laser emitting short (motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.

  13. A nonmusical paradigm for identifying absolute pitch possessors

    Science.gov (United States)

    Ross, David A.; Olson, Ingrid R.; Marks, Lawrence E.; Gore, John C.

    2004-09-01

    The ability to identify and reproduce sounds of specific frequencies is remarkable and uncommon. The etiology and defining characteristics of this skill, absolute pitch (AP), have been very controversial. One theory suggests that AP requires a specific type of early musical training and that the ability to encode and remember tones depends on these learned musical associations. An alternate theory argues that AP may be strongly dependent on hereditary factors and relatively independent of musical experience. To date, it has been difficult to test these hypotheses because all previous paradigms for identifying AP have required subjects to employ knowledge of musical nomenclature. As such, these tests are insensitive to the possibility of discovering AP in either nonmusicians or musicians of non-Western training. Based on previous literature in pitch memory, a paradigm is presented that is intended to distinguish between AP possessors and nonpossessors independent of the subjects' musical experience. The efficacy of this method is then tested with 20 classically defined AP possessors and 22 nonpossessors. Data from these groups strongly support the validity of the paradigm. The use of a nonmusical paradigm to identify AP may facilitate research into many aspects of this phenomenon.

  14. Nobel Lecture: From the Big Bang to the Nobel Prize and beyond

    Science.gov (United States)

    Mather, John C.

    NASA’s Cosmic Background Explorer satellite mission, the COBE, laid the foundations for modern cosmology by measuring the spectrum and anisotropy of the cosmic microwave background radiation and discovering the cosmic infrared background radiation. I describe the history of the COBE project, its scientific context, the people who built it, and the scientific results. The COBE observed the universe on the largest scales possible by mapping the cosmic microwave and infrared background radiation fields and determining their spectra. It produced conclusive evidence that the hot Big Bang theory of the early universe is correct, showed that the early universe was very uniform but not perfectly so, and that the total luminosity of post Big Bang objects is twice as great as previously believed. The COBE concept was developed by a Mission Definition Study Team appointed by NASA in 1976, based on three competing proposals submitted in 1974. The COBE was built in-house by Goddard Space Flight Center, with a helium cryostat provided by Ball Aerospace, and was launched on a Delta rocket built by McDonnell Douglas. It is in a circular orbit 900km above the Earth, in a plane inclined 99° to the equator and roughly perpendicular to the line to the Sun. It carried three instruments, a far infrared absolute spectrophotometer (FIRAS), a differential microwave radiometer with three channels (DMR), and a diffuse infrared background experiment (DIRBE). The helium cryostat cooled the FIRAS and DIRBE for 10months until the helium was exhausted, but operations continued for a total of 4years . Subsequent observations have confirmed the COBE results and led to measurements of the main cosmological parameters with a precision of a few percent.

  15. Absolute Paleointensity Techniques: Developments in the Last 10 Years (Invited)

    Science.gov (United States)

    Bowles, J. A.; Brown, M. C.

    2009-12-01

    The ability to determine variations in absolute intensity of the Earth’s paleomagnetic field has greatly enhanced our understanding of geodynamo processes, including secular variation and field reversals. Igneous rocks and baked clay artifacts that carry a thermal remanence (TRM) have allowed us to study field variations over timescales ranging from decades to billions of years. All absolute paleointensity techniques are fundamentally based on repeating the natural process by which the sample acquired its magnetization, i.e. a laboratory TRM is acquired in a controlled field, and the ratio of the natural TRM to that acquired in the laboratory is directly proportional to the ancient field. Techniques for recovering paleointensity have evolved since the 1930s from relatively unsophisticated (but revolutionary for their time) single step remagnetizations to the various complicated, multi-step procedures in use today. These procedures can be broadly grouped into two categories: 1) “Thellier-type” experiments that step-wise heat samples at a series of temperatures up to the maximum unblocking temperature of the sample, progressively removing the natural remanence (NRM) and acquiring a laboratory-induced TRM; and 2) “Shaw-type” experiments that combine alternating field demagnetization of the NRM and laboratory TRM with a single heating to a temperature above the sample’s Curie temperature, acquiring a total TRM in one step. Many modifications to these techniques have been developed over the years with the goal of identifying and/or accommodating non-ideal behavior, such as alteration and multi-domain (MD) remanence, which may lead to inaccurate paleofield estimates. From a technological standpoint, perhaps the most significant development in the last decade is the use of microwave (de)magnetization in both Thellier-type and Shaw-type experiments. By using microwaves to directly generate spin waves within the magnetic grains (rather than using phonons

  16. Field measurements of the global UV-B radiation: a comparison between a broad-band radiometer and a Brewer spectrophotometer

    International Nuclear Information System (INIS)

    Anav, A.; Moriconi, M.L.; Di Menno, M.; Giannoccolo, S.

    1996-01-01

    The spectral responsivity shape plays an important role in the prospect of a wide use of broad-band meters in the UV-B monitoring. As most UV-B broad-band meters have a responsivity approximating an erythemal action spectrum, a measurement campaign was planned to verify if such an instrument could be successfully used to measure the unfiltered global irradiance. A Yankee radiometer mod. UV-B 1 and a Brewer spectrophotometer, considered as a reference meter, were compared for this purpose. A short theoretical treatment of the Yankee radiometer response and some results of the comparison are shown. Only clear-sky days data are selected so that the UV-B radiation reaching the ground could be modelled as the sum of the direct and isotropic diffuse components. The comparison results show a good agreement between the two instruments and confirm the capability of a broad-band UV-B radiometer of correctly measuring the global irradiance

  17. Influence of Light Conditions and Light Sources on Clinical Measurement of Natural Teeth Color using VITA Easyshade Advance 4,0® Spectrophotometer. Pilot Study.

    Science.gov (United States)

    Posavec, Ivona; Prpić, Vladimir; Zlatarić, Dubravka Knezović

    2016-12-01

    The purpose of this study was to evaluate and compare lightness (L), chroma (C) and hue (h), green-red (a) and blue-yellow (b) character of the color of maxillary right central incisors in different light conditions and light sources. Two examiners who were well trained in digital color evaluation participated in the research. Intraclass correlation coefficients (ICCs) were used to analyze intra- and interobserver reliability. The LCh and L*a*b* values were determined at 08.15 and at 10.00 in the morning under three different light conditions. Tooth color was assessed in 10 subjects using intraoral spectrophotometer VITA Easyshade Advance 4.0 ® set at the central region of the vestibular surface of the measured tooth. Intra- and interobserver ICC values were high for both examiners and ranged from 0.57 to 0.99. Statistically significant differences in LCh and L*a*b* values measured in different time of the day and certain light condition were not found (p>0.05). Statistically significant differences in LCh and L*a*b* values measured under three different light conditions were not found, too (p>0.05). VITA Easyshade Advance 4.0 ® is reliable enough for daily clinical work in order to assess tooth color during the fabrication of esthtic appliances because it is not dependent on light conditions and light sources.

  18. [Variation in soil Mn fractions as affected by long-term manure amendment using atomic absorption spectrophotometer in a typical grassland of inner Mongolia].

    Science.gov (United States)

    Fu, Ming-ming; Jiang, Yong; Bai, Yong-fei; Zhang, Yu-ge; Xu, Zhu-wen; Li, Bo

    2012-08-01

    The effect of sheep manure amendment on soil manganese fractions was conducted in a 11 year experiment at inner Mongolia grassland, using sequential extraction procedure in modified Community Bureau of Reference, and determined by atomic absorption spectrophotometer. Five treatments with dry sheep manure addition rate 0, 50, 250, 750, and 1500 g x m(-2) x yr(-1), respectively, were carried out in this experiment. Results showed that the recovery rate for total Mn was 91.4%-105.9%, as the percentage recovered from the summation of the improved BCR results with aqua regia extractable contents, and it was 97.2%-102.9% from certified soil reference materials. Plant available exchangeable Mn could be enhanced by 47.89%, but reducible and total Mn contents decreased significantly under heavy application of manure at depth of 0-5 cm. The effect of manure amendment on Mn fractions was greater in 0-5 cm than in 5-10 cm soil layer. The results are benefit to micronutrient fractions determination and nutrient management in grassland soils.

  19. iHWG-μNIR: a miniaturised near-infrared gas sensor based on substrate-integrated hollow waveguides coupled to a micro-NIR-spectrophotometer.

    Science.gov (United States)

    Rohwedder, J J R; Pasquini, C; Fortes, P R; Raimundo, I M; Wilk, A; Mizaikoff, B

    2014-07-21

    A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.

  20. Effect of vital bleaching with solutions containing different concentrations of hydrogen peroxide and pineapple extract as an additive on human enamel using reflectance spectrophotometer: An in vitro study.

    Science.gov (United States)

    Vejai Vekaash, Chitra Janardhanan; Kumar Reddy, Tripuravaram Vinay; Venkatesh, Kondas Vijay

    2017-01-01

    This study aims to evaluate the color change in human enamel bleached with three different concentrations of hydrogen peroxide, containing pineapple extract as an additive in two different timings, using reflectance spectrophotometer. The study aimed to investigate the bleaching efficacy on natural teeth using natural enzymes. Baseline color values of 10 randomly selected artificially stained incisors were obtained. The specimens were divided into three groups of 20 teeth each: Group 1 - 30% hydrogen peroxide, Group II - 20% hydrogen peroxide, and Group III - 10% hydrogen peroxide. One half of the tooth was bleached with hydrogen peroxide, and other was bleached with hydrogen peroxide and pineapple extract for 20 min (Subgroup A) and 10 min (Subgroup B). The results were statistically analyzed using student's t -test. The mean ΔE values of Group IA (31.62 ± 0.9), Group IIA (29.85 ± 1.2), and Group IIIA (28.65 ± 1.2) showed statistically significant higher values when compared to the mean Δ E values of Group 1A (25.02 ± 1.2), Group IIA (22.86 ± 1.1), and Group IIIA (16.56 ± 1.1). Identical results were obtained in Subgroup B. The addition of pineapple extract to hydrogen peroxide resulted in effective bleaching.

  1. In situ analysis of proteins at high temperatures mediated by capillary-flow hydrothermal UV-vis spectrophotometer with a water-soluble chromogenic reagent.

    Science.gov (United States)

    Kawamura, Kunio; Nagayoshi, Hiroki; Yao, Toshio

    2010-05-14

    In situ monitoring of quantities, interactions, and conformations of proteins is essential for the study of biochemistry under hydrothermal environments and the analysis of hyperthermophilic organisms in natural hydrothermal systems on Earth. We have investigated the potential of a capillary-flow hydrothermal UV-vis spectrophotometer (CHUS) for performing in situ measurements of proteins and determining their behavior at extremely high temperatures, in combination with a chromogenic reagents probe, which interacts with the proteins. The spectral shift obtained using a combination of water-soluble porphyrin (TPPS) and bovine serum albumin (BSA) was the best among the spectral shifts obtained using different combinations of chromogenic reagents and proteins. The association behavior of TPPS with BSA was investigated in detail using CHUS at temperatures up to 175 degrees C and the association constant (K(ass)) of TPPS with BSA was successfully determined at temperatures up to 100 degrees C. The lnK(ass) values were inversely proportional to the T(-1) values in the temperature range 50-100 degrees C. These analyses showed for the first time that the decrease of association of TPPS with BSA is due to the conformational change, fragmentation, and/or denaturing of BSA rather than the decrease of the hydrophobic association between TPPS and BSA. This study conclusively demonstrates the usability of the CHUS system with a chromogenic reagent as an in situ detection and measurement system for thermostable proteins at extremely high temperatures. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Spectroscopic studies of model photo-receptors: validation of a nanosecond time-resolved micro-spectrophotometer design using photoactive yellow protein and α-phycoerythrocyanin.

    Science.gov (United States)

    Purwar, Namrta; Tenboer, Jason; Tripathi, Shailesh; Schmidt, Marius

    2013-09-13

    Time-resolved spectroscopic experiments have been performed with protein in solution and in crystalline form using a newly designed microspectrophotometer. The time-resolution of these experiments can be as good as two nanoseconds (ns), which is the minimal response time of the image intensifier used. With the current setup, the effective time-resolution is about seven ns, determined mainly by the pulse duration of the nanosecond laser. The amount of protein required is small, on the order of 100 nanograms. Bleaching, which is an undesirable effect common to photoreceptor proteins, is minimized by using a millisecond shutter to avoid extensive exposure to the probing light. We investigate two model photoreceptors, photoactive yellow protein (PYP), and α-phycoerythrocyanin (α-PEC), on different time scales and at different temperatures. Relaxation times obtained from kinetic time-series of difference absorption spectra collected from PYP are consistent with previous results. The comparison with these results validates the capability of this spectrophotometer to deliver high quality time-resolved absorption spectra.

  3. Determination of arsenic concentration in tiger tooth croaker (Otolithes ruber and indian halibut (Psettodes erumei using hydride generation atomic absorption spectrophotometer

    Directory of Open Access Journals (Sweden)

    E Rahimi

    2011-11-01

    Full Text Available Heavy metal contaminants in fish are of particular interest because of their potential risk to human. This study was undertaken to determine the levels of arsenic in two fish type including tiger tooth croaker and Indian halibut  in Esfahan. A total of 42 fish samples including 28 tiger tooth croaker (Otolithes ruber and 14 Indian halibut (Psettodes erumei were collected from retails of Esfahan from May 2010 to January 2011. For detection of arsenic contamination, the edible muscles of  fish samples were analyzed by hydride generation atomic absorption spectrophotometer. The arsenic contamination in fish samples were found to be in the range of 11 to 98 µg/kg. Concentration of arsenic in tiger tooth croaker and Indian halibut was 11-56 and 32-98 µg/kg, respectively. Arsenic concentrations were below the limit was acceptable to the World Health Organization. According to the results, the concentration of arsenic did not exceed the maximum acceptable intake limit.

  4. Development of a graphite probe calorimeter for absolute clinical dosimetry

    International Nuclear Information System (INIS)

    Renaud, James; Seuntjens, Jan; Sarfehnia, Arman; Marchington, David

    2013-01-01

    The aim of this work is to present the numerical design optimization, construction, and experimental proof of concept of a graphite probe calorimeter (GPC) conceived for dose measurement in the clinical environment (U.S. provisional patent 61/652,540). A finite element method (FEM) based numerical heat transfer study was conducted using a commercial software package to explore the feasibility of the GPC and to optimize the shape, dimensions, and materials used in its design. A functioning prototype was constructed inhouse and used to perform dose to water measurements under a 6 MV photon beam at 400 and 1000 MU/min, in a thermally insulated water phantom. Heat loss correction factors were determined using FEM analysis while the radiation field perturbation and the graphite to water absorbed dose conversion factors were calculated using Monte Carlo simulations. The difference in the average measured dose to water for the 400 and 1000 MU/min runs using the TG-51 protocol and the GPC was 0.2% and 1.2%, respectively. Heat loss correction factors ranged from 1.001 to 1.002, while the product of the perturbation and dose conversion factors was calculated to be 1.130. The combined relative uncertainty was estimated to be 1.4%, with the largest contributors being the specific heat capacity of the graphite (type B, 0.8%) and the reproducibility, defined as the standard deviation of the mean measured dose (type A, 0.6%). By establishing the feasibility of using the GPC as a practical clinical absolute photon dosimeter, this work lays the foundation for further device enhancements, including the development of an isothermal mode of operation and an overall miniaturization, making it potentially suitable for use in small and composite radiation fields. It is anticipated that, through the incorporation of isothermal stabilization provided by temperature controllers, a subpercent overall uncertainty will be achieved.

  5. Absolute pitch: effects of timbre on note-naming ability.

    Science.gov (United States)

    Vanzella, Patrícia; Schellenberg, E Glenn

    2010-11-11

    Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP possessors to identify. A musician's first instrument may also affect performance and extend the sensitive period for acquiring accurate AP. A large sample of AP possessors was recruited on-line. Participants were required to identity test tones presented in four different timbres: piano, pure tone, natural (sung) voice, and synthesized voice. Note-naming accuracy was better for non-vocal (piano and pure tones) than for vocal (natural and synthesized voices) test tones. This difference could not be attributed solely to vibrato (pitch variation), which was more pronounced in the natural voice than in the synthesized voice. Although starting music lessons by age 7 was associated with enhanced note-naming accuracy, equivalent abilities were evident among listeners who started music lessons on piano at a later age. Because the human voice is inextricably linked to language and meaning, it may be processed automatically by voice-specific mechanisms that interfere with note naming among AP possessors. Lessons on piano or other fixed-pitch instruments appear to enhance AP abilities and to extend the sensitive period for exposure to music in order to develop accurate AP.

  6. Accurate absolute measurement of trapped Cs atoms in a MOT

    International Nuclear Information System (INIS)

    Talavera O, M.; Lopez R, M.; Carlos L, E. de; Jimenez S, S.

    2007-01-01

    A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrologia, CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (σ + - σ - ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is l MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to 6 x 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%. (Author)

  7. Intraplate Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K. G.; Camelbeeck, T.

    2007-12-01

    We have conducted repeated absolute gravity (AG) measurements across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken since 2000 and repeated twice a year. Our analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36.7 nm s-2/year equivalent to 18.4 mm/yr is due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nms-2 to 43±29 nms-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. In Ostend, the AG time series agrees with tide gauge data, global mean sea level and altimeter measurements but disagrees with the CGPS. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes in an intraplate context.

  8. Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K.; Camelbeeck, T.

    2009-05-01

    Repeated absolute gravity (AG) measurements have been performed across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken in 2000 and repeated twice a year. Analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36 nm -2/year, equivalent to 18 mm/yr, is at least in parts due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nm s-2 to 43±29 nm s-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes.

  9. Absolute pitch: effects of timbre on note-naming ability.

    Directory of Open Access Journals (Sweden)

    Patrícia Vanzella

    2010-11-01

    Full Text Available Absolute pitch (AP is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names, it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP possessors to identify. A musician's first instrument may also affect performance and extend the sensitive period for acquiring accurate AP.A large sample of AP possessors was recruited on-line. Participants were required to identity test tones presented in four different timbres: piano, pure tone, natural (sung voice, and synthesized voice. Note-naming accuracy was better for non-vocal (piano and pure tones than for vocal (natural and synthesized voices test tones. This difference could not be attributed solely to vibrato (pitch variation, which was more pronounced in the natural voice than in the synthesized voice. Although starting music lessons by age 7 was associated with enhanced note-naming accuracy, equivalent abilities were evident among listeners who started music lessons on piano at a later age.Because the human voice is inextricably linked to language and meaning, it may be processed automatically by voice-specific mechanisms that interfere with note naming among AP possessors. Lessons on piano or other fixed-pitch instruments appear to enhance AP abilities and to extend the sensitive period for exposure to music in order to develop accurate AP.

  10. The need for an established allocation method when assessing absolute sustainability on a product level

    DEFF Research Database (Denmark)

    Ryberg, Morten; Owsianiak, Mikolaj; Hauschild, Michael Zwicky

    2015-01-01

    Assessment of absolute sustainability within life cycle assessment (LCA) framework is operational on the country scale. However, it is difficult to apply the existing approaches to products, which are typically the scope of LCAs. How should we assess whether a chair is (absolutely) sustainable? I...... allocation keys specific to each product group, e.g. mass for furniture, or economic revenue for IT. The proposed method facilitates assessment of absolute sustainability of products within the LCA framework....

  11. Absolute measurement of the viscosity of classical and quantum fluids by rotating-cylinder viscometers

    International Nuclear Information System (INIS)

    Donnelly, R.J.; LaMar, M.M.

    1987-01-01

    We discuss the use of rotating-cylinder viscometers to determine absolute shear viscosities of classical fluids and of helium II in the context of past and current knowledge of the stability and flow of these fluids between concentric cylinders. We identify a problem in measuring the absolute viscosity when the inner cylinder is rotating and the outer cylinder is at rest. We conclude by discussing the design of viscometers for absolute viscosity measurements in helium I and helium II

  12. Binomial Distribution Sample Confidence Intervals Estimation 7. Absolute Risk Reduction and ARR-like Expressions

    Directory of Open Access Journals (Sweden)

    Andrei ACHIMAŞ CADARIU

    2004-08-01

    Full Text Available Assessments of a controlled clinical trial suppose to interpret some key parameters as the controlled event rate, experimental event date, relative risk, absolute risk reduction, relative risk reduction, number needed to treat when the effect of the treatment are dichotomous variables. Defined as the difference in the event rate between treatment and control groups, the absolute risk reduction is the parameter that allowed computing the number needed to treat. The absolute risk reduction is compute when the experimental treatment reduces the risk for an undesirable outcome/event. In medical literature when the absolute risk reduction is report with its confidence intervals, the method used is the asymptotic one, even if it is well know that may be inadequate. The aim of this paper is to introduce and assess nine methods of computing confidence intervals for absolute risk reduction and absolute risk reduction – like function.Computer implementations of the methods use the PHP language. Methods comparison uses the experimental errors, the standard deviations, and the deviation relative to the imposed significance level for specified sample sizes. Six methods of computing confidence intervals for absolute risk reduction and absolute risk reduction-like functions were assessed using random binomial variables and random sample sizes.The experiments shows that the ADAC, and ADAC1 methods obtains the best overall performance of computing confidence intervals for absolute risk reduction.

  13. Autoshaping as a psychophysical paradigm: Absolute visual sensitivity in the pigeon

    Science.gov (United States)

    Passe, Dennis H.

    1981-01-01

    A classical conditioning procedure (autoshaping) was used to determine absolute visual threshold in the pigeon. This method provides the basis for a standardized visual psychophysical paradigm. PMID:16812228

  14. Absolute carrier phase effects in the two-color excitation of dipolar molecules

    International Nuclear Information System (INIS)

    Brown, Alex; Meath, W.J.; Kondo, A.E.

    2002-01-01

    The pump-probe excitation of a two-level dipolar (d≠0) molecule, where the pump frequency is tuned to the energy level separation while the probe frequency is extremely small, is examined theoretically as an example of absolute phase control of excitation processes. The state populations depend on the probe field's absolute carrier phase but are independent of the pump field's absolute carrier phase. Interestingly, the absolute phase effects occur for pulse durations much longer and field intensities much weaker than those required to see such effects in single pulse excitation

  15. Absolute cross sections from the ''boomerang model'' for resonant electron-molecule scattering

    International Nuclear Information System (INIS)

    Dube, L.; Herzenberg, A.

    1979-01-01

    The boomerang model is used to calculate absolute cross sections near the 2 Pi/sub g/ shape resonance in e-N 2 scattering. The calculated cross sections are shown to satisfy detailed balancing. The exchange of electrons is taken into account. A parametrized complex-potential curve for the intermediate N 2 /sup ts-/ ion is determined from a small part of the experimental data, and then used to calculate other properties. The calculations are in good agreement with the absolute cross sections for vibrational excitation from the ground state, the absolute cross section v = 1 → 2, and the absolute total cross section

  16. Development of a Shear Deformable Element Using the Absolute Nodal Coordinate Formulation

    National Research Council Canada - National Science Library

    Omar, Mohamed

    2000-01-01

    .... The effect of the shear deformation is accounted for without the need for introducing Timoshenko's shear coefficient By using the absolute coordinates, the nonlinear strain-displacement relationships...

  17. Absolute cardiovascular risk in a Fiji medical zone.

    Science.gov (United States)

    Gyaneshwar, Rajat; Naidu, Swaran; Raban, Magdalena Z; Naidu, Sheetal; Linhart, Christine; Morrell, Stephen; Tukana, Isimeli; Taylor, Richard

    2016-02-09

    The population of Fiji has experienced emergence of non-communicable disease (NCD) and a plateau in life expectancy over the past 20 years. A mini-STEPS survey (n = 2765) was conducted in Viseisei in Western Fiji to assess NCD risk factors (RFs) in i-Taukei (Melanesians) and those of Indian descent aged 25-64 years (response 73 %). Hypertension (HT) was defined as systolic blood pressure (BP) ≥140 mmHg or diastolic BP ≥90 mmHg or on medication for HT; type 2 diabetes mellitus (T2DM) as fasting plasma glucose ≥7.0 mmol/L or on medication for T2DM; and obesity as a body mass index (kilograms/height(metres)(2)) ≥30. Data were age-adjusted to 2007 Fiji Census. Associations between RFs and ethnicity/education were investigated. Comparisons with Fiji STEPS surveys were undertaken, and the absolute risk of a cardiovascular disease (CVD) event/death in 10 years was estimated from multiple RF charts. NCD/RFs increased with age except excessive alcohol intake and daily smoking (women) which declined. Daily smoking was higher in men 33 % (95 % confidence interval: 31-36) than women 14 % (12-116); women were more obese 40 % (37-43) than men 23 % (20-26); HT was similar in men 37 % (34-40) and women 34 % (31-36), as was T2DM in men 15 % (13-17) and women 17 % (15-19). i-Taukei men had an odds ratio (OR) of 0.41 (0.28-0.58) for T2DM compared to Indians (1.00); and i-Taukei (both sexes) had a higher OR for obesity and low fruit/vegetable intake, daily smoking, excessive alcohol intake and HT in females. Increasing education correlated with lesser smoking, but with higher obesity and lower fruit/vegetable intake. Compared to the 2011 Fiji STEPS survey, no significant differences were evident in obesity, HT or T2DM prevalences. The proportion (40-64 years) classified at high or very high risk (≥20 %) of a CVD event/death (over 10 years) based on multiple RFs was 8.3 % for men (8.1 % i-Taukei, 8.5 % Indian), and 6.7 % for women (7.9 % i-Taukei, 6.0 % Indian). The results

  18. The absolute magnitude distribution of Kuiper Belt objects

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, Wesley C. [Herzberg Institute of Astrophysics, 5071 West Saanich Road, Victoria, BC V9E 2E7 (Canada); Brown, Michael E. [Division of Geological and Planetary Sciences, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Morbidelli, Alessandro [Laboratoire Lagrange, UMR7293, Université de Nice Sophia-Antipolis, CNRS, Observatoire de la Côte d' Azur, BP 4229, F-06304 Nice (France); Parker, Alex [Department of Astronomy, University of California at Berkeley, Berkeley, CA 94720 (United States); Batygin, Konstantin, E-mail: wesley.fraser@nrc.ca [Institute for Theory and Computation, Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS 51, Cambridge, MA 02138 (United States)

    2014-02-20

    Here we measure the absolute magnitude distributions (H-distribution) of the dynamically excited and quiescent (hot and cold) Kuiper Belt objects (KBOs), and test if they share the same H-distribution as the Jupiter Trojans. From a compilation of all useable ecliptic surveys, we find that the KBO H-distributions are well described by broken power laws. The cold population has a bright-end slope, α{sub 1}=1.5{sub −0.2}{sup +0.4}, and break magnitude, H{sub B}=6.9{sub −0.2}{sup +0.1} (r'-band). The hot population has a shallower bright-end slope of, α{sub 1}=0.87{sub −0.2}{sup +0.07}, and break magnitude H{sub B}=7.7{sub −0.5}{sup +1.0}. Both populations share similar faint-end slopes of α{sub 2} ∼ 0.2. We estimate the masses of the hot and cold populations are ∼0.01 and ∼3 × 10{sup –4} M {sub ⊕}. The broken power-law fit to the Trojan H-distribution has α{sub 1} = 1.0 ± 0.2, α{sub 2} = 0.36 ± 0.01, and H {sub B} = 8.3. The Kolmogorov-Smirnov test reveals that the probability that the Trojans and cold KBOs share the same parent H-distribution is less than 1 in 1000. When the bimodal albedo distribution of the hot objects is accounted for, there is no evidence that the H-distributions of the Trojans and hot KBOs differ. Our findings are in agreement with the predictions of the Nice model in terms of both mass and H-distribution of the hot and Trojan populations. Wide-field survey data suggest that the brightest few hot objects, with H{sub r{sup ′}}≲3, do not fall on the steep power-law slope of fainter hot objects. Under the standard hierarchical model of planetesimal formation, it is difficult to account for the similar break diameters of the hot and cold populations given the low mass of the cold belt.

  19. The absolute magnitude distribution of Kuiper Belt objects

    International Nuclear Information System (INIS)

    Fraser, Wesley C.; Brown, Michael E.; Morbidelli, Alessandro; Parker, Alex; Batygin, Konstantin

    2014-01-01

    Here we measure the absolute magnitude distributions (H-distribution) of the dynamically excited and quiescent (hot and cold) Kuiper Belt objects (KBOs), and test if they share the same H-distribution as the Jupiter Trojans. From a compilation of all useable ecliptic surveys, we find that the KBO H-distributions are well described by broken power laws. The cold population has a bright-end slope, α 1 =1.5 −0.2 +0.4 , and break magnitude, H B =6.9 −0.2 +0.1 (r'-band). The hot population has a shallower bright-end slope of, α 1 =0.87 −0.2 +0.07 , and break magnitude H B =7.7 −0.5 +1.0 . Both populations share similar faint-end slopes of α 2 ∼ 0.2. We estimate the masses of the hot and cold populations are ∼0.01 and ∼3 × 10 –4 M ⊕ . The broken power-law fit to the Trojan H-distribution has α 1 = 1.0 ± 0.2, α 2 = 0.36 ± 0.01, and H B = 8.3. The Kolmogorov-Smirnov test reveals that the probability that the Trojans and cold KBOs share the same parent H-distribution is less than 1 in 1000. When the bimodal albedo distribution of the hot objects is accounted for, there is no evidence that the H-distributions of the Trojans and hot KBOs differ. Our findings are in agreement with the predictions of the Nice model in terms of both mass and H-distribution of the hot and Trojan populations. Wide-field survey data suggest that the brightest few hot objects, with H r ′ ≲3, do not fall on the steep power-law slope of fainter hot objects. Under the standard hierarchical model of planetesimal formation, it is difficult to account for the similar break diameters of the hot and cold populations given the low mass of the cold belt.

  20. Global change and the measurement of absolute sea-level

    Science.gov (United States)

    Diamante, John M.; Pyle, Thomas E.; Carter, William E.; Scherer, Wolfgang

    -300) required for global climate research programmes (WYRTKI and PUGH, 1984) need to be upgraded to “sea-level observatory” status, in terms of sensors and geodetic control, to build a two tier sea-level network that will provide the data needed to solve many problems of both relative and absolute sea-level change. Such a network will provide basic information supporting research on a wide range of questions related to “global change”.