WorldWideScience

Sample records for absolute neutron flux

  1. Measurement of absolute neutron flux in LWSCR based on the nuclear track method

    International Nuclear Information System (INIS)

    Sadeghzadeh, J.; Nassiri Mofakham, N.; Khajehmiri, Z.

    2012-01-01

    Highlights: ► Up to now the spectral parameters of thermal neutrons are measured with activation foils that are not always reliable in low flux systems. ► We applied a solid state nuclear track detector to measure the absolute neutron flux in the light water sub-critical reactor (LWSCR). ► Experiments concerning fission track detecting were performed and were investigated using the Monte Carlo code MCNP. ► The neutron fluxes obtained in experiment are in fairly good agreement with the results obtained by MCNP. - Abstract: In the present paper, a solid state nuclear track detector is applied to measure the absolute neutron flux in the light water sub-critical reactor (LWSCR) in Nuclear Science and Technology Research Institute (NSTRI). Up to now, the spectral parameters of thermal neutrons have been measured with activation foils that are not always reliable in low flux systems. The method investigated here is the irradiation method. Experiments concerning fission track detecting were performed. The experiment including neutron flux calculation method has also been investigated using the Monte Carlo code MCNP. The analysis shows that the values of neutron flux obtained by experiment are in fairly good agreement with the results obtained by MCNP. Thus, this method may be able to predict the absolute value of neutron flux at LWSCR and other similar reactors.

  2. Flux depression and the absolute measurement of the thermal neutron flux density

    International Nuclear Information System (INIS)

    Bensch, Friedrich.

    1977-01-01

    The thermal neutron flux depression in a diffusing medium by an absorbing foil has been treated in numerous papers. The results are re-examined in an attempt to find a uniform and physically meaningful representation of the 'activation correction'. This quantity can be split up into a combination of probabilities. Thus, it is possible to determine the activation correction for any moderator and foil material. Measurements confirm the utility of the concepts introduced

  3. Self-Powered Neutron Detector Qualification for Absolute On-Line In-Pile Neutron Flux Measurements in BR2

    Science.gov (United States)

    Vermeeren, L.; Wéber, M.

    2003-06-01

    A set of ten Self-Powered Neutron Detectors with Co, Rh and Ag emitters has been irradiated in several channels of the BR2 research reactor at SCK•CEN aiming at a comparison of their performance as thermal neutron flux detectors under various conditions. To allow for a correct interpretation of their signals, all detector sensitivity contributions (prompt and delayed) were calculated using a dedicated Monte Carlo model. The various contributions were also measured separately; the agreement between calculated and experimental data, including data from activation dosimetry, was excellent. Detailed neutron flux profiles were obtained from the SPND data, after correction for the finite detector lengths and for the slow response of delayed SPNDs.

  4. PC based system for absolute neutron flux-spectrum measurements. Final report for the period 1 April 1994 - 15 December 1997

    International Nuclear Information System (INIS)

    Dobrea, D.

    1998-01-01

    When measuring absolute neutron flux-spectra, thin detector foils are irradiated in a neutron field. The absolute activity of isotopes generated by activation or fission reactions (fission products) is then measured, using an efficiency calibrated high resolution gamma-ray spectroscopy system, and the absolute reaction rates for their production is determined. Finally the flux-spectrum is determined based upon the reaction rate values. A general method to obtain flux-spectra from the reaction rate is the unfolding method. The above process involves computations of photopeak area, reaction rate, flux perturbation corrections and flux-spectrum. The PC's are well suited for the data processing system outlined above. Using available interfaces, the PC's can be involved even in the data acquisition. Graphical facilities allow decision upon the data processing flow

  5. SYSTEMATIC UNCERTAINTIES IN THE SPECTROSCOPIC MEASUREMENTS OF NEUTRON STAR MASSES AND RADII FROM THERMONUCLEAR X-RAY BURSTS. III. ABSOLUTE FLUX CALIBRATION

    Energy Technology Data Exchange (ETDEWEB)

    Güver, Tolga [Istanbul University, Science Faculty, Department of Astronomy and Space Sciences, Beyazıt, 34119, Istanbul (Turkey); Özel, Feryal; Psaltis, Dimitrios [Department of Astronomy, University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Marshall, Herman [Center for Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Guainazzi, Matteo [European Space Astronomy Centre of ESA, P.O. Box 78, Villanueva de la Cañada, E-28691 Madrid (Spain); Díaz-Trigo, Maria [ESO, Karl-Schwarzschild-Strasse 2, D-85748 Garching bei München (Germany)

    2016-09-20

    Many techniques for measuring neutron star radii rely on absolute flux measurements in the X-rays. As a result, one of the fundamental uncertainties in these spectroscopic measurements arises from the absolute flux calibrations of the detectors being used. Using the stable X-ray burster, GS 1826–238, and its simultaneous observations by Chandra HETG/ACIS-S and RXTE /PCA as well as by XMM-Newton EPIC-pn and RXTE /PCA, we quantify the degree of uncertainty in the flux calibration by assessing the differences between the measured fluxes during bursts. We find that the RXTE /PCA and the Chandra gratings measurements agree with each other within their formal uncertainties, increasing our confidence in these flux measurements. In contrast, XMM-Newton EPIC-pn measures 14.0 ± 0.3% less flux than the RXTE /PCA. This is consistent with the previously reported discrepancy with the flux measurements of EPIC-pn, compared with EPIC MOS1, MOS2, and ACIS-S detectors. We also show that any intrinsic time-dependent systematic uncertainty that may exist in the calibration of the satellites has already been implicity taken into account in the neutron star radius measurements.

  6. Absolute measurements of the thermal neutron flux by the foil activation method using the 4πβ-γ coincidence technique

    International Nuclear Information System (INIS)

    Aranda Amado Furieri, R.C. de.

    1977-12-01

    An analysis of the correction factors required for the β-γ coincidence method is presented together with a listing of the various formulae involved in the determination of radioactive sources. The detection system including the activation detectores are described and the results are shown for the absolute measurements of thermal neutron flux carried out in the core of the Argonaut Reactor, at Instituto de Engenharia Nuclear (IEN), Brazil. (Author) [pt

  7. The final power calibration of the IPEN/MB-01 nuclear reactor for various configurations obtained from the measurements of the absolute average neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alexandre Fonseca Povoa da, E-mail: alexandre.povoa@mar.mil.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil); Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto Credidio; Lima, Ana Cecilia de Souza; Betti, Flavio; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The use of neutron activation foils is a widely spread technique applied to obtain nuclear parameters then comparing the results with those calculated using specific methodologies and available nuclear data. By irradiation of activation foils and subsequent measurement of its induced activity, it is possible to determine the neutron flux at the position of irradiation. The power level during operation of the reactor is a parameter which is directly proportional to the average neutron flux throughout the core. The objective of this work is to gather data from irradiation of gold foils symmetrically placed along a cylindrically configured core which presents only a small excess reactivity in order to derive the power generated throughout the spatial thermal and epithermal neutron flux distribution over the core of the IPEN/MB-01 Nuclear Reactor, eventually lending to a proper calibration of its nuclear channels. The foils are fixed in a Lucite plate then irradiated with and without cadmium sheaths so as to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux resulting from the gold foils irradiation, and the average power digitally indicated by the nuclear channel number 6, allows for the calibration of the nuclear channels of the reactor. The reactor power level obtained by thermal neutron flux mapping was (74.65 ± 2.45) watts to a mean counting per seconds of 37881 cps to nuclear channel number 10 a pulse detector, and 0.719.10{sup -5} ampere to nuclear linear channel number 6 (a non-compensated ionization chamber). (author)

  8. Notes on neutron flux measurement

    International Nuclear Information System (INIS)

    Alcala Ruiz, F.

    1984-01-01

    The main purpose of this work is to get an useful guide to carry out topical neutron flux measurements. Although the foil activation technique is used in the majority of the cases, other techniques, such as those based on fission chambers and self-powered neutron detectors, are also shown. Special interest is given to the description and application of corrections on the measurement of relative and absolute induced activities by several types of detectors (scintillators, G-M and gas proportional counters). The thermal arid epithermal neutron fluxes, as determined in this work, are conventional or effective (West cots fluxes), which are extensively used by the reactor experimentalists; however, we also give some expressions where they are related to the integrated neutron fluxes, which are used in neutron calculations. (Author) 16 refs

  9. Neutron flux monitor

    International Nuclear Information System (INIS)

    Oda, Naotaka.

    1993-01-01

    The device of the present invention greatly saves an analog processing section such as an analog filter and an analog processing circuit. That is, the device of the present invention comprises (1) a neutron flux detection means for detecting neutron fluxed in the reactor, (2) a digital filter means for dividing signals corresponding to the detected neutron fluxes into predetermined frequency band regions, (3) a calculation processing means for applying a calculation processing corresponding to the frequency band regions to the neutron flux detection signals divided by the digital filter means. With such a constitution, since the neutron detection signals are processed by the digital filter means, the accuracy is improved and the change for the property of the filter is facilitated. Further, when a neutron flux level is obtained, a calculation processing corresponding to the frequency band region can be conducted without the analog processing circuit. Accordingly, maintenance and accuracy are improved by greatly decreasing the number of parts. Further, since problems inherent to the analog circuit are solved, neutron fluxes are monitored at high reliability. (I.S.)

  10. Compact neutron flux monitor

    International Nuclear Information System (INIS)

    Madhavi, V.; Phatak, P.R.; Bahadur, C.; Bayala, A.K.; Jakati, R.K.; Sathian, V.

    2003-01-01

    Full text: A compact size neutron flux monitor has been developed incorporating standard boards developed for smart radiation monitors. The sensitivity of the monitors is 0.4cps/nV. It has been tested up to 2075 nV flux with standard neutron sources. It shows convincing results even in high flux areas like 6m away from the accelerator in RMC (Parel) for 106/107 nV. These monitors have a focal and remote display, alarm function with potential free contacts for centralized control and additional provision of connectivity via RS485/Ethernet. This paper describes the construction, working and results of the above flux monitor

  11. Neutron flux monitoring device

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro.

    1995-01-01

    In a neutron flux monitoring device, there are disposed a neutron flux measuring means for outputting signals in accordance with the intensity of neutron fluxes, a calculation means for calculating a self power density spectrum at a frequency band suitable to an object to be measured based on the output of the neutron flux measuring means, an alarm set value generation means for outputting an alarm set value as a comparative reference, and an alarm judging means for comparing the alarm set value with the outputted value of the calculation means to judge requirement of generating an alarm and generate an alarm in accordance with the result of the judgement. Namely, the time-series of neutron flux signals is put to fourier transformation for a predetermined period of time by the calculation means, and from each of square sums for real number component and imaginary number component for each of the frequencies, a self power density spectrum in the frequency band suitable to the object to be measured is calculated. Then, when the set reference value is exceeded, an alarm is generated. This can reliably prevent generation of erroneous alarm due to neutron flux noises and can accurately generate an alarm at an appropriate time. (N.H.)

  12. NEUTRON FLUX INTENSITY DETECTION

    Science.gov (United States)

    Russell, J.T.

    1964-04-21

    A method of measuring the instantaneous intensity of neutron flux in the core of a nuclear reactor is described. A target gas capable of being transmuted by neutron bombardment to a product having a resonance absorption line nt a particular microwave frequency is passed through the core of the reactor. Frequency-modulated microwave energy is passed through the target gas and the attenuation of the energy due to the formation of the transmuted product is measured. (AEC)

  13. Validation of absolute axial neutron flux distribution calculations with MCNP with 197Au(n,γ)198Au reaction rate distribution measurements at the JSI TRIGA Mark II reactor.

    Science.gov (United States)

    Radulović, Vladimir; Štancar, Žiga; Snoj, Luka; Trkov, Andrej

    2014-02-01

    The calculation of axial neutron flux distributions with the MCNP code at the JSI TRIGA Mark II reactor has been validated with experimental measurements of the (197)Au(n,γ)(198)Au reaction rate. The calculated absolute reaction rate values, scaled according to the reactor power and corrected for the flux redistribution effect, are in good agreement with the experimental results. The effect of different cross-section libraries on the calculations has been investigated and shown to be minor. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. From Hubble's NGSL to Absolute Fluxes

    Science.gov (United States)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  15. Reactor neutron flux measuring device

    International Nuclear Information System (INIS)

    Okutani, Yasushi; Hayakawa, Toshifumi.

    1994-01-01

    The present invention concerns a device for displaying an approximate neutron flux distribution to recognize the neutron flux distribution of the whole reactor in a short period of time. The device of the present invention displays, the results of measurement for neutron fluxes collected by a data collecting section on every results of the measurements at measuring points situating at horizontally identical positions of the reactor core. In addition, every results of the measurements at the measuring points situating at the identical height in the reactor core are accumulated, and the results of the integration are graphically displayed. With such procedures, the neutron flux distribution in the entire reactor is approximately displayed. Existent devices could not recognize the neutron flux distribution of the entire reactor at a glance and it took much time for the recognition. The device of the present invention can recognize the neutron flux distribution of the entire reactor in a short period of time. (I.S.)

  16. Absolute calibration of a cold and thermal neutron detector using monochromatic neutron beam

    Science.gov (United States)

    Choi, Jin Ha; Cude-Woods, Christopher; Ito, Takeyasu; Young, Albert

    2017-09-01

    Time of flight spectra for cold neutrons exiting the moderator volume of the LANSCE UCN source has been obtained using a commercial neutron scintillator, EJ-426, coupled to a Hamamatsu R1355. The absolute efficiency for this detector system was determined using a 37.4 meV (monochromatic) neutron beam from the Neutron Powder Diffraction Facility (NPDF) at North Carolina State University's PULSTAR reactor. We measured the absolute neutron flux at the NPDF through thin foil activation and explored threshold effects through analysis of the measured pulse height distribution for effectively pure neutron signals from the NPDF beam. Non-uniformity of the flux profile across the detector and the detection efficiency as a function of the point of incidence of neutrons on the scintillator was explored using a X-Y translation system to perform scans using either fixed or movable apertures. The results are generally consistent with our expectations for this system, and provide a quantitative assessment of the sensitivity of this system to cold and thermal neutrons. This project was funded by the National Science Foundation and the Department of Energy.

  17. Looking for high neutron fluxes

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1994-01-01

    The neutron is a powerful and versatile probe of both the structure and dynamics of condensed matter. However unlike other techniques such as X-ray, electron or light scattering, its interaction with matter is rather weak. Historically neutron scattering has always been intensity limited and scientists are always looking for more intense sources. These come in two kinds - fission reactors and spallation sources (in which neutrons are released from a target bombardment by beams). Unfortunately the power density of high flux reactors is approaching a technical limit and it will be difficult to achieve a large increase of neutron fluxes above typical present values as represented for example by the high flux reactor at ILL, Grenoble

  18. Neutron fluxes in test reactors

    Energy Technology Data Exchange (ETDEWEB)

    Youinou, Gilles Jean-Michel [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    Communicate the fact that high-power water-cooled test reactors such as the Advanced Test Reactor (ATR), the High Flux Isotope Reactor (HFIR) or the Jules Horowitz Reactor (JHR) cannot provide fast flux levels as high as sodium-cooled fast test reactors. The memo first presents some basics physics considerations about neutron fluxes in test reactors and then uses ATR, HFIR and JHR as an illustration of the performance of modern high-power water-cooled test reactors.

  19. High flux compact neutron generators

    International Nuclear Information System (INIS)

    Reijonen, J.; Lou, T.-P.; Tolmachoff, B.; Leung, K.-N.; Verbeke, J.; Vujic, J.

    2001-01-01

    Compact high flux neutron generators are developed at the Lawrence Berkeley National Laboratory. The neutron production is based on D-D or D-T reaction. The deuterium or tritium ions are produced from plasma using either a 2 MHz or 13.56 MHz radio frequency (RF) discharge. RF-discharge yields high fraction of atomic species in the beam which enables higher neutron output. In the first tube design, the ion beam is formed using a multiple hole accelerator column. The beam is accelerated to energy of 80 keV by means of a three-electrode extraction system. The ion beam then impinges on a titanium target where either the 2.4 MeV D-D or 14 MeV D-T neutrons are generated. The MCNP computation code has predicted a neutron flux of ∼10 11 n/s for the D-D reaction at beam intensity of 1.5 A at 150 kV. The neutron flux measurements of this tube design will be presented. Recently new compact high flux tubes are being developed which can be used for various applications. These tubes also utilize RF-discharge for plasma generation. The design of these tubes and the first measurements will be discussed in this presentation

  20. EUV mirror based absolute incident flux detector

    Science.gov (United States)

    Berger, Kurt W.

    2004-03-23

    A device for the in-situ monitoring of EUV radiation flux includes an integrated reflective multilayer stack. This device operates on the principle that a finite amount of in-band EUV radiation is transmitted through the entire multilayer stack. This device offers improvements over existing vacuum photo-detector devices since its calibration does not change with surface contamination.

  1. Neutron flux control systems validation

    International Nuclear Information System (INIS)

    Hascik, R.

    2003-01-01

    In nuclear installations main requirement is to obtain corresponding nuclear safety in all operation conditions. From the nuclear safety point of view is commissioning and start-up after reactor refuelling appropriate period for safety systems verification. In this paper, methodology, performance and results of neutron flux measurements systems validation is presented. Standard neutron flux measuring chains incorporated into the reactor protection and control system are used. Standard neutron flux measuring chain contains detector, preamplifier, wiring to data acquisition unit, data acquisition unit, wiring to display at control room and display at control room. During reactor outage only data acquisition unit and wiring and displaying at reactor control room is verified. It is impossible to verify detector, preamplifier and wiring to data acquisition recording unit during reactor refuelling according to low power. Adjustment and accurate functionality of these chains is confirmed by start-up rate (SUR) measurement during start-up tests after refuelling of the reactors. This measurement has direct impact to nuclear safety and increase operational nuclear safety level. Briefly description of each measuring system is given. Results are illustrated on measurements performed at Bohunice NPP during reactor start-up tests. Main failures and their elimination are described (Authors)

  2. Neutron flux enhancement at LASREF

    International Nuclear Information System (INIS)

    Sommer, W.F.; Ferguson, P.D.; Wechsler, M.S.

    1991-01-01

    The accelerator at the Los Alamos Meson Physics Facility produces a 1-mA beam of protons at an energy of 800 MeV. Since 1985, the Los Alamos Spallation Radiation Effects Facility (LASREF) has made use of the neutron flux that is generated as the incident protons interact with the nuclei in targets and a copper beam stop. A variety of basic and applied experiments in radiation damage and radiation effects have been completed. Recent studies indicate that the flux at LASREF can be increased by at least a factor of ten from the present level of about 5 E+17 m -2 s -1 . This requires changing the beam-stop material from Cu to W and optimizing the geometry of the beam-target interaction region. These studies are motivated by the need for a large volume, high energy, and high intensity neutron source in the development of materials for advanced energy concepts such as fusion reactors. 18 refs., 7 figs., 2 tabs

  3. Improvement of neutron source introduction method for absolute measurements of low reactor power

    International Nuclear Information System (INIS)

    Yamamoto, Toshihiro; Miyoshi, Yoshinori

    1999-01-01

    The neutron source introduction method was applied to absolute measurements of low reactor power at the Static Experiment Critical Facility STACY. To obtain the effective neutron source intensity more accurately, which is a key parameter for the source introduction method, the neutron source is newly defined as fission neutrons from the first fission reaction caused by neutrons emitted from the external neutron source. To obtain the newly defined effective neutron source intensity, the probability that a neutron from the external neutron source causes a fission reaction is calculated using the Monte Carlo code MCNP. This calculation took into consideration the three-dimensional complicated core structures. Furthermore, the fission reaction distribution, fundamental mode forward and adjoint flux distribution in a critical state were calculated using the three-dimensional transport code THREEDANT. Following the principle of the neutron source introduction method, an external neutron source was inserted near the STACY core tank and the reactor power was measured. The reactor powers by the neutron source introduction method were in good agreement with the ones from the analyses of the FP activity generated by high power operation. (author)

  4. The absolute energy flux envelopes of B type stars.

    Science.gov (United States)

    Underhill, A. B.

    1972-01-01

    Absolute energy flux envelopes covering the region of 1100 to 6000 A for main-sequence stars of types B3, B7 and A0 derived from published, ground-based observations and from spectrum scans with OAO-II are presented. These flux envelopes are compared with the predicted flux envelopes from lightly line-blanketed model atmospheres. The line blanketing at wavelengths shorter than 3000 A is severe, about one-half the predicted light being observed at 1600 A. These results demonstrate that a model which represents well the observed visible spectrum of a star may fail seriously for representing the ultraviolet spectrum.

  5. Spacecraft-produced neutron fluxes on Skylab

    Science.gov (United States)

    Quist, T. C.; Furst, M.; Burnett, D. S.; Baum, J. H.; Peacock, C. L., Jr.; Perry, D. G.

    1977-01-01

    Estimates of neutron fluxes in different energy ranges are reported for the Skylab spacecraft. Detectors composed of uranium, thorium, and bismuth foils with mica as a fission track recorder, as well as boron foils with cellulose acetate as an alpha-particle recorder, were deployed at different positions in the Orbital Workshop. It was found that the Skylab neutron flux was dominated by high energy (greater than 1 MeV) contributions and that there was no significant time variation in the fluxes. Firm upper limits of 7-15 neutrons/sq cm-sec, depending on the detector location in the spacecraft, were established for fluxes above 1 MeV. Below 1 MeV, the neutron fluxes were about an order of magnitude lower. The neutrons are interpreted as originating from the interactions of leakage protons from the radiation belt with the spacecraft.

  6. Measurements of neutron flux from an inertial-electrostatic confinement device

    International Nuclear Information System (INIS)

    Westenskow, G.A.

    1975-08-01

    A neutron-detection system was built for the purpose of measuring the neutron flux from an Inertial-Electrostatic Confinement Device located at Brigham Young University. A BF 3 proportional counter was used for absolute flux measurements and a pair of scintillation detectors was used to compare neutron output under different operating conditions. The detectors were designed to be compatible with the operating conditions of the device and to be able to measure small changes in neutron output. The detectors were calibrated using a Pu-Be source with corrections made for laboratory conditions. Performance of the counting system was checked and data were collected on the neutron flux from the device

  7. A fission ionization detector for neutron flux measurements at a spallation source

    Energy Technology Data Exchange (ETDEWEB)

    Wender, S.A. (Los Alamos National Lab., Los Alamos, NM (United States)); Balestrini, S. (Los Alamos National Lab., Los Alamos, NM (United States)); Brown, A. (Los Alamos National Lab., Los Alamos, NM (United States)); Haight, R.C. (Los Alamos National Lab., Los Alamos, NM (United States)); Laymon, C.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lee, T.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lisowski, P.W. (Los Alamos National Lab., Los Alamos, NM (United States)); McCorkle, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Nelson, R.O. (Los Alamos National Lab., Los Alamos, NM (United States)); Parker, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Hill, N.W. (Oak Ridge National Lab., Oak Ridge, TN (United States))

    1993-11-15

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  8. A fission ionization detector for neutron flux measurements at a spallation source

    International Nuclear Information System (INIS)

    Wender, S.A.; Balestrini, S.; Brown, A.; Haight, R.C.; Laymon, C.M.; Lee, T.M.; Lisowski, P.W.; McCorkle, W.; Nelson, R.O.; Parker, W.; Hill, N.W.

    1993-01-01

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  9. Isotopic characterization and thermal neutron flux determination of a PuBe neutron source.

    Science.gov (United States)

    Purty, Ravi Ankit; Akanchha; Prasad, Shikha

    2017-07-01

    The Indian Institute of Technology Kanpur (IIT Kanpur) possesses a PuBe neutron source facility with an initial activity of 5 Ci, dated September 1966 (nearly 50 years ago). An understanding of the present activity and the rate of its change will allow implementation of proper radiological safety procedures and future radiological safety planning. Knowing the absolute neutron flux will help us in future neutron activation studies. These details are also important to ensure proper security precautions. In our work, we attempt to identify the isotopic composition to determine the rate of change of the source and the absolute thermal neutron flux of plutonium beryllium (PuBe) sample at IIT Kanpur. We have used gamma-ray spectroscopy for determining the isotopic composition of the PuBe neutron source. After utilizing gamma-ray spectroscopy it is found that the source is composed of 239 Pu and a small amount of 241 Am is present as an impurity. The mass ratio of 241 Am to 239 Pu is found to be approximately 18.1µg/g with an uncertainty of 1.39%. Delayed gamma neutron activation analysis (DGNAA) is used to determine the thermal neutron flux of the same PuBe neutron source using copper, cobalt, nickel and cadmium samples. The average thermal neutron flux as calculated from DGNAA is approximately 1.27×10 3 n/(cm 2 -s) at 1cm above the PuBe neutron source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. EL-2 reactor: Thermal neutron flux distribution

    International Nuclear Information System (INIS)

    Rousseau, A.; Genthon, J.P.

    1958-01-01

    The flux distribution of thermal neutrons in EL-2 reactor is studied. The reactor core and lattices are described as well as the experimental reactor facilities, in particular, the experimental channels and special facilities. The measurement shows that the thermal neutron flux increases in the central channel when enriched uranium is used in place of natural uranium. However the thermal neutron flux is not perturbed in the other reactor channels by the fuel modification. The macroscopic flux distribution is measured according the radial positioning of fuel rods. The longitudinal neutron flux distribution in a fuel rod is also measured and shows no difference between enriched and natural uranium fuel rods. In addition, measurements of the flux distribution have been effectuated for rods containing other material as steel or aluminium. The neutron flux distribution is also studied in all the experimental channels as well as in the thermal column. The determination of the distribution of the thermal neutron flux in all experimental facilities, the thermal column and the fuel channels has been made with a heavy water level of 1825 mm and is given for an operating power of 1000 kW. (M.P.)

  11. Gravitational effects on planetary neutron flux spectra

    Science.gov (United States)

    Feldman, W. C.; Drake, D. M.; O'Dell, R. D.; Brinkley, F. W., Jr.; Anderson, R. C.

    1989-01-01

    The effects of gravity on the planetary neutron flux spectra for planet Mars, and the lifetime of the neutron, were investigated using a modified one-dimensional diffusion accelerated neutral-particle transport code, coupled with a multigroup cross-section library tailored specifically for Mars. The results showed the presence of a qualitatively new feature in planetary neutron leakage spectra in the form of a component of returning neutrons with kinetic energies less than the gravitational binding energy (0.132 eV for Mars). The net effect is an enhancement in flux at the lowest energies that is largest at and above the outermost layer of planetary matter.

  12. Neutron flux measurement utilizing Campbell technique

    International Nuclear Information System (INIS)

    Kropik, M.

    2000-01-01

    Application of the Campbell technique for the neutron flux measurement is described in the contribution. This technique utilizes the AC component (noise) of a neutron chamber signal rather than a usually used DC component. The Campbell theorem, originally discovered to describe noise behaviour of valves, explains that the root mean square of the AC component of the chamber signal is proportional to the neutron flux (reactor power). The quadratic dependence of the reactor power on the root mean square value usually permits to accomplish the whole current power range of the neutron flux measurement by only one channel. Further advantage of the Campbell technique is that large pulses of the response to neutrons are favoured over small pulses of the response to gamma rays in the ratio of their mean square charge transfer and thus, the Campbell technique provides an excellent gamma rays discrimination in the current operational range of a neutron chamber. The neutron flux measurement channel using state of the art components was designed and put into operation. Its linearity, accuracy, dynamic range, time response and gamma discrimination were tested on the VR-1 nuclear reactor in Prague, and behaviour under high neutron flux (accident conditions) was tested on the TRIGA nuclear reactor in Vienna. (author)

  13. Research on measurement of neutron flux in irradiation channels of research reactor

    International Nuclear Information System (INIS)

    Yin Zhitao; Lv Zheng; Wang Yulin; Zheng Wuqin

    2014-01-01

    Relative distribution of thermal neutron flux in the irradiation channel is measured by classical activation foil method. After that, on a representative point in the irradiation channel, neutron temperature and absolute neutron flux are also measured. Cadmium ratio correction method is used to check the experiment result in the end. Comparative analysis shows that the results from two different methods are agreed pretty well, which adds the credibility of experiment results. (authors)

  14. 242Pu absolute neutron-capture cross section measurement

    Science.gov (United States)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.

    2017-09-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ) cross section could be set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ) cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ) En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ) cross section.

  15. 242Pu absolute neutron-capture cross section measurement

    Directory of Open Access Journals (Sweden)

    Buckner M.Q.

    2017-01-01

    Full Text Available The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ cross section could be set according to the known 239Pu(n,f resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ cross section.

  16. Neutron flux stabilization in the NG-150 neutron generators

    International Nuclear Information System (INIS)

    Kuz'min, L.E.; Makarov, S.A.; Pronman, I.M.

    1986-01-01

    Problem of metal tritium target lifetime increase and neutron flux stabilization in the NG-150 neutron generators is studied. Possibility on neutron flux stabilization using the mass analyzer for low-angle (4 deg and 41 deg) mass separation of a beam in thre components, which fall on a target simultaneously, is confirmed experimentally. Basic generator parameters are: accelerating voltage of 150 kV, total beam current on a target of 1.5 mA, beam current density of 0.3-1.6 mA/cm 2 , beam diameter of 8 mm. The initial neutron flux on the targets of 0.73 mg/cm 2 thick constituted 1.1x10 11 ssup(-1). The neutron flux monitoring was accomplished from recoil proton recording by a plastic scintillator. Flux decrease by more than 5% served as a signel for measuring mass analyzer magnetic field providing beam displacement on a target and restoration of the given flux. The NG-150 generator neutron flux stabilization was attained during 2h

  17. An alternative method for the measurement of neutron flux

    Indian Academy of Sciences (India)

    Here, the neutron flux inferred from the neutron count rate obtained with R-12 SDD shows an excellent agreement with the flux inferred from the neutron dose rate in a non-dissipative medium. Keywords. Neutron dose; neutron flux; superheated droplet detector; bubble nucleation. PACS Nos 29.40.Rg; 29.40.–n; 29.25.Dz. 1.

  18. A theoretical model for predicting neutron fluxes for cyclic Neutron ...

    African Journals Online (AJOL)

    A theoretical model has been developed for prediction of thermal neutron fluxes required for cyclic irradiations of a sample to obtain the same activity previously used for the detection of any radionuclide of interest. The model is suitable for radiotracer production or for long-lived neutron activation products where the ...

  19. Thermal and epithermal neutron flux distributions measurement in thermal column of TRR using an experimental-simulation method.

    Science.gov (United States)

    Adeli, Ruhollah; Kasesaz, Yaser; Shirmardi, Seyed Pezhman; Ezaty, Arsalan

    2018-03-01

    For designing an appropriate neutron beam, the determination of neutron flux at any irradiation facility is an important key factor. Due to the importance of determining the thermal and epithermal neutron fluxes in a typical thermal column of a reactor, a simple and accurate technique is introduced in this study. Absolute thermal and epithermal fluxes were measured experimentally at a certain point using the foil activation method by neutron bombardment of bare and cadmium covered Au foils. The relative neutron fluxes were also derived simply by means of Monte Carlo simulation by accurate modelling of the reactor components. Finally, by normalization of the relative distribution flux with regard to information about the absolute neutron flux, the accurate thermal and epithermal neutron distributions were derived, separately. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  1. Dual neutron flux/temperature measurement sensor

    Science.gov (United States)

    Mihalczo, John T.; Simpson, Marc L.; McElhaney, Stephanie A.

    1994-01-01

    Simultaneous measurement of neutron flux and temperature is provided by a single sensor which includes a phosphor mixture having two principal constituents. The first constituent is a neutron sensitive 6LiF and the second is a rare-earth activated Y203 thermophosphor. The mixture is coated on the end of a fiber optic, while the opposite end of the fiber optic is coupled to a light detector. The detected light scintillations are quantified for neutron flux determination, and the decay is measured for temperature determination.

  2. Neutron flux measurement by mobile detectors

    International Nuclear Information System (INIS)

    Verchain, M.

    1987-01-01

    Various incore instrumentation systems and their technological evolution are first reviewed. Then, for 1300 MWe PWR nuclear power plant, temperature and neutron flux measurement are described. Mobile fission chambers, with their large measuring range and accurate location allow a good knowledge of the core. Other incore measures are possible because of flux detector thimble tubes inserted in the reactor core [fr

  3. Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor

    International Nuclear Information System (INIS)

    Yavar, A.R.; Sarmani, S.B.; Wood, A.K.; Fadzil, S.M.; Radir, M.H.; Khoo, K.S.

    2011-01-01

    Determination of thermal to fast neutron flux ratio (f fast ) and fast neutron flux (φ fast ) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The f fast and subsequently φ fast were determined using the absolute method. The f fast ranged from 48 to 155, and the φ fast was found in the range 1.03x10 10 -4.89x10 10 n cm -2 s -1 . These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

  4. Neutrons in the moon. [neutron flux and production rate calculations

    Science.gov (United States)

    Kornblum, J. J.; Fireman, E. L.; Levine, M.; Aronson, A.

    1973-01-01

    Neutron fluxes for energies between 15 MeV and thermal at depths of 0 to 300 g/sq cm in the moon are calculated by the discrete ordinate mathod with the ANISN code. With the energy spectrum of Lingenfelter et al. (1972). A total neutron-production rate for the moon of 26 plus or minus neutrons/sq cm sec is determined from the Ar-37 activity measurements in the Apollo 16 drill string, which are found to have a depth dependence in accordance with a neutron source function that decreases exponentially with an attenuation length of 155 g/sq cm.

  5. Measurements of thermal and fast neutron fluxes at the TRIGA reactor

    International Nuclear Information System (INIS)

    Zerdin, F.; Grabovsek, Z.; Klinc, T.; Solinc, H.

    1966-01-01

    Gold foils were placed at different positions in the TRIGA reactor core and in the experimental devices. Absolute values of the thermal neutron flux at these positions were obtained by coincidence method. Preliminary fast neutron spectrum was measured by threshold detector and by 'Li 6 sandwich' detector. A short description of the applied method and obtained measurements results are included [sl

  6. Absolute calibration of neutron detectors on the C-2U advanced beam-driven FRC

    Energy Technology Data Exchange (ETDEWEB)

    Magee, R. M., E-mail: rmagee@trialphaenergy.com; Clary, R.; Korepanov, S.; Jauregui, F.; Allfrey, I.; Garate, E.; Valentine, T.; Smirnov, A. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    In the C-2U fusion energy experiment, high power neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. The diagnosis of the fast ion pressure in these high-performance plasmas is therefore critical, and the measurement of the flux of neutrons from the deuterium-deuterium (D-D) fusion reaction is well suited to the task. Here we describe the absolute, in situ calibration of scintillation neutron detectors via two independent methods: firing deuterium beams into a high density gas target and calibration with a 2 × 10{sup 7} n/s AmBe source. The practical issues of each method are discussed and the resulting calibration factors are shown to be in good agreement. Finally, the calibration factor is applied to C-2U experimental data where the measured neutron rate is found to exceed the classical expectation.

  7. Neutron Flux Measurement Produced by BNCT Target using Proton Beam

    International Nuclear Information System (INIS)

    Ha, Jang Ho; Kim, Yong Kyun; Chai, Jong Seo; Kim, Jong Kyung

    2005-01-01

    We are investigating neutron production target system performance for boron captured neutron therapy (BNCT). The epithermal neutron is useful for this therapy and in present study we performed a simple method to measure neutron flux and energy, which are important for the accurate cancer therapy. The simple method and result of neutron flux and energy measurement experiment are presented

  8. Measurements of neutron flux in the RA reactor

    International Nuclear Information System (INIS)

    Raisic, N.

    1961-12-01

    This report includes the following separate parts: Thermal neutron flux in the experimental channels od RA reactor; Epithermal neutron flux in the experimental channels od RA reactor; Fast neutron flux in the experimental channels od RA reactor; Thermal neutron flux in the thermal column and biological experimental channel; Neutronic measurements in the RA reactor cell; Temperature reactivity coefficient of the RA reactor; design of the device for measuring the activity of wire [sr

  9. Criticality experiments to provide benchmark data on neutron flux traps

    International Nuclear Information System (INIS)

    Bierman, S.R.

    1988-06-01

    The experimental measurements covered by this report were designed to provide benchmark type data on water moderated LWR type fuel arrays containing neutron flux traps. The experiments were performed at the US Department of Energy Hanford Critical Mass Laboratory, operated by Pacific Northwest Laboratory. The experimental assemblies consisted of 2 /times/ 2 arrays of 4.31 wt % 235 U enriched UO 2 fuel rods, uniformly arranged in water on a 1.891 cm square center-to-center spacing. Neutron flux traps were created between the fuel units using metal plates containing varying amounts of boron. Measurements were made to determine the effect that boron loading and distance between the fuel and flux trap had on the amount of fuel required for criticality. Also, measurements were made, using the pulse neutron source technique, to determine the effect of boron loading on the effective neutron multiplications constant. On two assemblies, reaction rate measurements were made using solid state track recorders to determine absolute fission rates in 235 U and 238 U. 14 refs., 12 figs., 7 tabs

  10. Device for controlling neutron flux

    International Nuclear Information System (INIS)

    Hirukawa, Koji.

    1979-01-01

    Purpose: To separately provide a reflux-type control tube and a scramming control rod, and arrange respective control tube groups concentrically from the core to the outside, and add a monitoring material thereto, thereby simplifying control system, flattening and controlling the core power. Constitution: At the central part of four fuel assemblies there are arranged reflux type control tubes filled with a solution of a neutron control substance, and four of the fundamental units are assembled and scramming control rods and provided at the center of these fundamental units in a freely insertable and removable manner, thereby forming a unit. The units of reflux type control tubes filled with the solutions of the neutron control substances having different concentrations are arranged concentrically from the core to the outside. Further, a monitoring substance such as phosphoric acid or the like, displaying similar behaviors as the solution is added in the solution, and the concentration of the solution is continuously measured. (Sekiya, K.)

  11. Research on determine the absolute neutron output of distributed pulse generators

    International Nuclear Information System (INIS)

    Li Bojun; Tang Zhangkui; Wang Dong; Yang Gaozhao; Peng Taiping

    2009-01-01

    In order to determine the absolute neutron output of distributed pulse generators, we deduced equivalent length to deal with experimental data, according to the different layout and weighting of multiple pulse generators. The deposited energy in scintillation crystal and the integral flux which drilling through crystal interface was simulated by MCNP code. The result shows the simulated proportion of different distributed pulse generators is approximately agreed with experimental data. The validity of the equivalent length model was proved by the consistent results between calculation and experimental data. (authors)

  12. Self-powered neutron flux detector assembly

    International Nuclear Information System (INIS)

    Allan, C.J.; McIntyre, I.L.

    1980-01-01

    A self-powered neutron flux detector has both the central emitter electrode and its surrounding collector electrode made of inconel 600. The lead cables may also be made of inconel. Other nickel alloys, or iron, nickel, titamium, chromium, zirconium or their alloys may also be used for the electrodes

  13. Electronic Reliability and the Environmental Thermal Neutron Flux

    National Research Council Canada - National Science Library

    Clark, John

    2002-01-01

    .... The goal of this project is to characterize the environmental thermal neutron flux with respect to electronic reliability by performing measurements of the thermal neutron flux in various locations...

  14. Neutron flux enhancement in the NRAD reactor

    International Nuclear Information System (INIS)

    Weeks, A.A.; Heidel, C.C.; Imel, G.R.

    1988-01-01

    In 1987 a series of experiments were conducted at the NRAD reactor facility at Argonne National Laboratory - West (ANL-W) to investigate the possibility of increasing the thermal neutron content at the end of the reactor's east beam tube through the use of hydrogenous flux traps. It was desired to increase the thermal flux for a series of experiments to be performed in the east radiography cell, in which the enhanced flux was required in a relatively small volume. Hence, it was feasible to attempt to focus the cross section of the beam to a smaller area. Two flux traps were constructed from unborated polypropylene and tested to determine their effectiveness. Both traps were open to the entire cross-sectional area of the neutron beam (as it emerges from the wall and enters the beam room). The sides then converged such that at the end of the trap the beam would be 'focused' to a greater intensity. The differences in the two flux traps were primarily in length, and hence angle to the beam as the inlet and outlet cross-sectional areas were held constant. The experiments have contributed to the design of a flux trap in which a thermal flux of nearly 10 9 was obtained, with an enhancement of 6.61

  15. Neutron flux enhancement in the NRAD reactor

    International Nuclear Information System (INIS)

    Weeks, A.A.; Heidel, C.C.; Imel, G.R.

    1988-01-01

    In 1987 a series of experiments were conducted at the NRAD reactor facility at Argonne National Laboratory - West (ANL-W) to investigate the possibility of increasing the thermal neutron content at the end of the reactor's east beam tube through the use of hydrogenous flux traps. It was desired to increase the thermal flux for a series of experiments to be performed in the east radiography cell, in which the enhanced flux was required in a relatively small volume. Hence, it was feasible to attempt to focus the cross section of the beam to a smaller area. Two flux traps were constructed from unborated polypropylene and tested to determine their effectiveness. Both traps were open to the entire cross-sectional area of the neutron beam (as it emerges from the wall and enters the beam room). The sides then converged such that at the end of the trap the beam would be 'focused' to a greater intensity. The differences in the two flux traps were primarily in length, and hence angle to the beam as the inlet and outlet cross-sectional areas were held constant. It should be noted that merely placing a slab of polypropylene in the beam will not yield significant multiplication as neutrons are primarily scattered away

  16. Notes on neutron flux measurement; Notas sobre medida de flujos neutronicos

    Energy Technology Data Exchange (ETDEWEB)

    Alcala Ruiz, F.

    1984-07-01

    The main purpose of this work is to get an useful guide to carry out topical neutron flux measurements. Although the foil activation technique is used in the majority of the cases, other techniques, such as those based on fission chambers and self-powered neutron detectors, are also shown. Special interest is given to the description and application of corrections on the measurement of relative and absolute induced activities by several types of detectors (scintillators, G-M and gas proportional counters). The thermal arid epithermal neutron fluxes, as determined in this work, are conventional or effective (West cots fluxes), which are extensively used by the reactor experimentalists; however, we also give some expressions where they are related to the integrated neutron fluxes, which are used in neutron calculations. (Author) 16 refs.

  17. Neutron fluxes and spectra of the neutron guide tubes in the upgraded JRR-3

    International Nuclear Information System (INIS)

    Kawabata, Y.; Suzuki, M.; Tsuruno, A.; Onishi, N.

    1992-01-01

    A cold neutron source with two thermal and three cold neutron guide tubes has been installed in the upgraded JRR-3. Neutron fluxes, time-of-flight spectra and the gain of the cold neutron source were measured at the end of the neutron guide tubes. The neutron beam distributions were found by neutron radiography films. (orig.)

  18. An alternative method for the measurement of neutron flux

    Indian Academy of Sciences (India)

    Abstract. A simple and easy method for measuring the neutron flux is presented. This paper deals with the experimental verification of neutron dose rate–flux relationship for a non-dissipative medium. Though the neutron flux cannot be obtained from the dose rate in a dissipative medium, experimental result shows that for ...

  19. An alternative method for the measurement of neutron flux

    Indian Academy of Sciences (India)

    A simple and easy method for measuring the neutron flux is presented. This paper deals with the experimental verification of neutron dose rate–flux relationship for a non-dissipative medium. Though the neutron flux cannot be obtained from the dose rate in a dissipative medium, experimental result shows that for ...

  20. Simulation of neutron fluxes around the W7-X Stellarator

    International Nuclear Information System (INIS)

    Andersson, Jenny

    1999-12-01

    A new fusion experiment, the WENDELSTEIN 7-X Stellarator (W7-X), will be undertaken in Greifswald in Germany. Measurements of the neutron flux will provide information on fusion reaction rates and possibly also on ion temperatures as function of time. For this purpose moderating neutron counters will be designed, tested, calibrated and eventually used at W7-X. Extensive Monte-Carlo simulations have been performed in order to select the most suitable detector and moderator combination with a flat response function and highest achievable efficiency. Different detector configurations with different moderating materials have been tried out, showing that a 32 cm thick graphite moderating BF 3 -counter gives the desired flat response and sufficient efficiency. Neutron spectra calculations have been made for different torus models and the influence of floor, walls and ceiling (i.e. reactor hall) have been investigated. Presented results suggest that a more detailed torus model significantly reduces the number of neutron counts at the detector. Calculations including the reactor hall indicate a tendency of shifting the neutron spectra towards the thermal region. The main part of the scattered neutrons are back-scattered from the floor. Finally, calculations on the graphite moderating BF 3 -counter in the detailed torus environment were performed in order to assess the absolute response function under the influence of the reactor hall. The results show that the detector count rate will increase by only 5-7 % when the reactor hall is taken into account. With a stellarator generating 10 12 to 10 16 neutrons per second the detector count rate will be 2x10 5 to 2x10 9 neutrons per second

  1. A measurement of the absolute neutron beam polarization produced by an optically pumped 3He neutron spin filter

    International Nuclear Information System (INIS)

    Rich, D.R.; Bowman, J.D.; Crawford, B.E.; Delheij, P.P.J.; Espy, M.A.; Haseyama, T.; Jones, G.; Keith, C.D.; Knudson, J.; Leuschner, M.B.; Masaike, A.; Masuda, Y.; Matsuda, Y.; Penttilae, S.I.; Pomeroy, V.R.; Smith, D.A.; Snow, W.M.; Szymanski, J.J.; Stephenson, S.L.; Thompson, A.K.; Yuan, V.

    2002-01-01

    The capability of performing accurate absolute measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with an absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically pumped polarized 3 He spin filter and a relative transmission measurement technique. 3 He was polarized using the Rb spin-exchange method. We describe the measurement technique, present our results, and discuss some of the systematic effects associated with the method

  2. Generating energy dependent neutron flux maps for effective ...

    African Journals Online (AJOL)

    For activation analysis and irradiation scheme of miniature neutron source reactor, designers or engineers usually require information on thermal neutron flux levels and other energy group flux levels (such as fast, resonance and epithermal). A methodology for readily generating such flux maps and flux profiles for any ...

  3. Growth of zircaloy 4 under neutron flux

    International Nuclear Information System (INIS)

    Morize, P.; Baicry, J.; Morlot, G.; Sciers, P.; Lehmann, D.

    1982-06-01

    Between 300 and 385 0 C, and under neutron fluxes between 0.5 and 2.10 14 n/cm 2 /s, the growth of zircaloy tubes is nil in the plane perpendicular to the axis, and can be represented by the equation: Δl/l=4.6610 -14 (phit)sup(0.49) in the axial direction. In the area investigated, neither the irradiation temperature nor the instantaneous flux has any effect on the metallurgical state (relieved or recrystallized) [fr

  4. Strong flux of low-energy neutrons produced by thunderstorms.

    Science.gov (United States)

    Gurevich, A V; Antonova, V P; Chubenko, A P; Karashtin, A N; Mitko, G G; Ptitsyn, M O; Ryabov, V A; Shepetov, A L; Shlyugaev, Yu V; Vildanova, L I; Zybin, K P

    2012-03-23

    We report here for the first time about the registration of an extraordinary high flux of low-energy neutrons generated during thunderstorms. The measured neutron count rate enhancements are directly connected with thunderstorm discharges. The low-energy neutron flux value obtained in our work is a challenge for the photonuclear channel of neutron generation in thunderstorm: the estimated value of the needed high-energy γ-ray flux is about 3 orders of magnitude higher than that one observed.

  5. Systematic investigation of background sources in neutron flux measurements with a proton-recoil silicon detector

    Energy Technology Data Exchange (ETDEWEB)

    Marini, P., E-mail: marini@cenbg.in2p3.fr [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Mathieu, L. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Acosta, L. [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, México D.F. 01000 (Mexico); Aïche, M.; Czajkowski, S.; Jurado, B.; Tsekhanovich, I. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France)

    2017-01-01

    Proton-recoil detectors (PRDs), based on the well known standard H(n,p) elastic scattering cross section, are the preferred instruments to perform precise quasi-absolute neutron flux measurements above 1 MeV. The limitations of using a single silicon detector as PRD at a continuous neutron beam facility are investigated, with the aim of extending such measurements to neutron energies below 1 MeV. This requires a systematic investigation of the background sources affecting the neutron flux measurement. Experiments have been carried out at the AIFIRA facility to identify these sources. A study on the role of the silicon detector thickness on the background is presented and an energy limit on the use of a single silicon detector to achieve a neutron flux precision better than 1% is given.

  6. The measurements of thermal neutron flux distribution in a paraffin

    Indian Academy of Sciences (India)

    The term `thermal flux' implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 ms-1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of ...

  7. The measurements of thermal neutron flux distribution in a paraffin ...

    Indian Academy of Sciences (India)

    The term `thermal flux' implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 ms-1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of ...

  8. First flux measurement in a SINQ supermirror neutron guide

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, S.; Schlumpf, N.; Bauer, G. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    On Dec. 3, 1996, the Swiss spallation neutron source SINQ was taken into operation and produced its first neutrons successfully. The neutron spectrum within one of the supermirror guides was estimated by a chopper Time-of-Flight method. The result shows a 30% higher neutron intensity at the flux maximum than expected from previous Monte-Carlo simulations. (author) 1 fig., 4 refs.

  9. Radial Flux Distribution of Low-Energy Neutrons.

    Science.gov (United States)

    Higinbotham, J.

    1979-01-01

    Describes an experiment designed to illustrate the basic principle involved in the process of moderation of fast neutrons by water, and the monitoring of the low-energy neutron flux using indium as a probe. (GA)

  10. Investigating The Neutron Flux Distribution Of The Miniature Neutron Source Reactor MNSR Type

    International Nuclear Information System (INIS)

    Nguyen Hoang Hai; Do Quang Binh

    2011-01-01

    Neutron flux distribution is the important characteristic of nuclear reactor. In this article, four energy group neutron flux distributions of the miniature neutron source reactor MNSR type versus radial and axial directions are investigated in case the control rod is fully withdrawn. In addition, the effect of control rod positions on the thermal neutron flux distribution is also studied. The group constants for all reactor components are generated by the WIMSD code, and the neutron flux distributions are calculated by the CITATION code. The results show that the control rod positions only affect in the planning area for distribution in the region around the control rod. (author)

  11. Determination of TFTR far-field neutron detector efficiencies by local neutron flux spectrum measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jassby, D.L.; Ascione, G.; Kugel, H.W.; Roquemore, A.L.; Barcelo, T.W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Kumar, A. [University of California, Los Angeles, California 90024 (United States)

    1997-01-01

    Neutron detectors have often been located on the tokamak fusion test reactor (TFTR) test cell floor 3 m or more from the vacuum vessel for ease of detector access, to reduce radiation damage, minimize count saturation problems, and to avoid high magnetic fields. These detectors include Si surface-barrier diodes, fission chambers, natural diamond detectors, and T{sub 2} production in a moderated {sup 3}He cell. To evaluate the performance of these detectors during deuterium{endash}tritium (D{endash}T) operation, we determined the neutron flux spectrum incident on the principal detector enclosure using nuclide sample sets containing Al, Ti, Fe, Co, Cu, Zn, Ni, Zr, Nb, In, and Au activation foils. Foils were installed and then removed after ample exposure to TFTR D{endash}T neutrons. High efficiency, high purity Ge detectors were used for gamma spectroscopy of the irradiated foils. The incident neutron fluence and spectral distribution were unfolded from the measured results, and used to derive absolute detector efficiencies. {copyright} {ital 1997 American Institute of Physics.}

  12. The measurements of thermal neutron flux distribution in a paraffin ...

    Indian Academy of Sciences (India)

    neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger–. Muller counter and NaI(Tl)) was the aim of this project. The relative differences of the outcome of the experiments were between ...

  13. Device for measuring neutron-flux distribution density

    International Nuclear Information System (INIS)

    Rozenbljum, N.D.; Mitelman, M.G.; Kononovich, A.A.; Kirsanov, V.S.; Zagadkin, V.A.

    1977-01-01

    An arrangement is described for measuring the distribution of neutron flux density over the height of a nuclear reactor core and which may be used for monitoring energy release or for detecting deviations of neutron flux from an optimal level so that subsequent balance can be achieved. It avoids mutual interference of detectors. Full constructional details are given. (UK)

  14. The measurements of thermal neutron flux distribution in a paraffin ...

    Indian Academy of Sciences (India)

    at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger–. Muller counter and NaI(Tl)) was the aim of this project. The relative differences of the ...

  15. Far-Ultraviolet Absolute Flux of α Virginis

    Science.gov (United States)

    Morales, Carmen; Trapero, Joaquín; Gómez, José F.; Giménez, Álvaro; Orozco, Verónica; Bowyer, Stuart; Edelstein, Jerry; Korpela, Eric; Lampton, Michael; Cobb, Jeff

    2000-02-01

    We present the far-ultraviolet spectrum of α Virginis taken with Espectrógrafo Ultravioleta extremo para la Radiación Difusa (EURD) spectrograph on board MINISAT-01. The spectral range covered is from ~900 to 1080 Å with 5 Å spectral resolution. We have fitted Kurucz models to IUE spectra of α Vir and compared the extension of the model to our wavelengths with EURD data. This comparison shows that EURD fluxes are consistent with the prediction of the model within ~20%-30%, depending on the reddening assumed. EURD fluxes are consistent with Voyager observations but are ~60% higher than most previous rocket observations of α Vir. Based on the development and utilization of the Espectrógrafo Ultravioleta de Radiación Difusa, a collaboration of the Spanish Instituto Nacional de Técnica Aeroespacial and the Center for EUV Astrophysics, University of California, Berkeley.

  16. Analyzer of neutron flux in real time

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Carrillo M, R.A.; Balderas, E.G.

    1999-01-01

    With base in the study of the real signals of neutron flux of instability events occurred in the Laguna Verde nuclear power plant where the nucleus oscillation phenomena of the reactor are in the 0 to 2.5 Hz range, it has been seen the possibility about the development a surveillance and diagnostic equipment capable to analyze in real time the behavior of nucleus in this frequencies range. An important method for surveillance the stability of the reactor nucleus is the use of the Power spectral density which allows to determine the frequencies and amplitudes contained in the signals. It is used an instrument carried out by LabVIEW graphic programming with a data acquisition card of 16 channels which works at Windows 95/98 environment. (Author)

  17. Cadmium filtered neutron flux determination. Comparison of activation methods

    International Nuclear Information System (INIS)

    Ollui-Mboulou, Magloire.

    1979-01-01

    Neutron fluxes under cadmium filters are determined by the cadmium ratio and sandwich activation methods. The thermal neutron flux levels obtained with 7 detectors of different kinds: In, Au, Ag, W, Co, Mn, Zn are compared. The cadmium ratio method was used in locations for which the epithermal and thermal neutron flux ratio are quite different. By irradiating materials under different thicknesses of cadmium it was possible to establish experimental curves from which the flux depression factors for intermediate neutrons may be determined whatever the thickness of the filter used. Whereas the cadmium ratio method can only measure the mean flux above the cadmium cut-off energy the sandwich method enables the flux value to be determined in a narrow band around the resonance energy of each detector used [fr

  18. Absolute measurement of the DT primary neutron yield on the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Leeper R.J.

    2013-11-01

    Full Text Available The measurement of the absolute neutron yield produced in inertial confinement fusion target experiments conducted on the National Ignition Facility (NIF is essential in benchmarking progress towards the goal of achieving ignition on this facility. This paper describes three independent diagnostic techniques that have been developed to make accurate and precise DT neutron yield measurements on the NIF.

  19. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  20. Temporal variation of the neutron flux in the carousel facility of a TRIGA reactor

    International Nuclear Information System (INIS)

    Jacimovic, R.; Stegnar, P.; Trkov, A.

    2003-01-01

    In this work we focused on identifying quantitatively the temporal (time-dependent) variation of neutron flux in the carousel facility (CF) of TRIGA reactor at the 'Jozef Stefan' Institute (IJS) for core No. 176, set up in April 2002. The measurements are based on neutron detectors (ionisation chambers), which surround the graphite reflector of the reactor core. In principle, the variations of the neutron flux produce a systematic error in the results obtained by absolute or 'quasi' absolute measuring techniques (such as neutron activation analysis (NAA) by the k 0 -standardization method), which assume constant conditions during irradiation. The results of our study show that for typical irradiation of 20 hours in channels of the CF aligned in the direction of the ionisation chamber (safety channel) the time-dependent variation of the neutron flux is about 6-8%. In the k 0 method, which we are using for routine work at the IJS, this variation introduced a systematic error in the results up to 4.6%, depending on the half-life of investigated radionuclide. (author)

  1. Neutron flux measurement at the Baksan Underground Scintillation Telescope

    Science.gov (United States)

    Kochkarov, M. M.; Boliev, M. M.; Dzaparova, I. M.; Novoseltseva, R. V.; Novoseltsev, Yu. F.; Petkov, V. B.; Volchenko, V. I.; Volchenko, G. V.; Yanin, A. F.

    2018-01-01

    The characteristics of fast neutrons produced by cosmic-ray muons at the Baksan Underground Scintillation Telescope (BUST) are investigated. A novel approach to the problem consists in estimating the neutron flux by the production rate of the unstable radioactive nuclide 12 B in the ( n, p) reaction on carbon nuclei of the BUST organic scintillator. The processing of the data collected in 2002-2015 yielded {N_{{{12}_B}}} = 337 ± 2.5 events consistent with those of the reaction 12 C( n, p)12 B. For the BUST internal planes, the background of fast neutrons with E > 28.6 MeV is experimentally estimated as Φ ∝ 10-11cm-2 s-1. This is lower than the theoretically predicted total neutron flux by nearly two orders of magnitude. The disagreement with predictions is attributed to the suppression of neutron flux in the external scintillator planes of the detector.

  2. Measurements of neutron flux distributions in the core of the Ljubljana TRIGA Mark II Reactor

    International Nuclear Information System (INIS)

    Rant, J.; Ravnik, M.; Mele, I.; Dimic, V.

    2008-01-01

    Recently the Ljubljana TRIGA Mark II Reactor has been refurbished and upgraded to pulsed operation. To verify the core design calculations using TRIGAP and PULSTR1 codes and to obtain necessary data for future irradiation and neutron beam experiments, an extensive experimental program of neutron flux mapping and neutron field characterization was carried out. Using the existing neutron measuring thimbles complete axial and radial distributions in two radial directions were determined for two different core configurations. For one core configuration the measurements were also carried out in the pulsed mode. For flux distributions thin Cu (relative measurements) and diluted Au wires (absolute values) were used. For each radial position the cadmium ratio was determined in two axial levels. The core configuration was rather uniform, well defined (fresh fuel of a single type, including fuelled followers) and compact (no irradiation channels or gaps), offering unique opportunity to test the computer codes for TRIGA reactor calculations. The neutron flux measuring procedures and techniques are described and the experimental results are presented. The agreement between the predicted and measured power peaking factors are within the error limits of the measurements (<±5%) and calculations (±10%). Power peaking occurs in the B ring, and in the A ring (centre) there is a significant flux depression. (authors)

  3. Global Maps of Lunar Neutron Fluxes from the LEND Instrument

    Science.gov (United States)

    Litvak, M. L.; Mitrofanov, I. G.; Sanin, A.; Malakhov, A.; Boynton, W. V.; Chin, G.; Droege, G.; Evans, L. G.; Garvin, J.; Golovin, D. V.; hide

    2012-01-01

    The latest neutron spectrometer measurements with the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) are presented. It covers more than 1 year of mapping phase starting on 15 September 2009. In our analyses we have created global maps showing regional variations in the flux of thermal (energy range neutrons (>0.5 MeV), and compared these fluxes to variances in soil elemental composition, and with previous results obtained by the Lunar Prospector Neutron Spectrometer (LPNS). We also processed data from LEND collimated detectors and derived a value for the collimated signal of epithermal neutrons based on the comparative analysis with the LEND omnidirectional detectors. Finally, we have compared our final (after the data reduction) global epithermal neutron map with LPNS data.

  4. Neutron flux profile monitor for use in a fission reactor

    Science.gov (United States)

    Kopp, Manfred K.; Valentine, Kenneth H.

    1983-01-01

    A neutron flux monitor is provided which consists of a plurality of fission counters arranged as spaced-apart point detectors along a delay line. As a fission event occurs in any one of the counters, two delayed current pulses are generated at the output of the delay line. The time separation of the pulses identifies the counter in which the particular fission event occured. Neutron flux profiles of reactor cores can be more accurately measured as a result.

  5. Determination of the neutron flux in the reactor zones with the strong neutron absorption and leakage

    International Nuclear Information System (INIS)

    Ljubenov, V.; Milosevic, M.

    2004-01-01

    The procedures for the numerical and experimental determination of the neutron flux in the zones with the strong neutron absorption and leakage are described in this paper. Numerical procedure is based on the SCALE-4.4a code system application with the use of Dancoff factor determined by the VEGA2DAN code. Experimental methodology consists of the irradiated foils activity measurement, and foil averaged neutron absorption cross-section determination via mentioned SCALE- 4.4a calculation procedure. The proposed procedures have been applied for the determination of the neutron flux in the internal neutron converter used with the RB reactor core configuration number 114. (author) [sr

  6. HAV-1-A multipurpose multimonitor for reactor neutron flux characterization

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Alvarez, I.; Herrera, E.; Lima, L.; Tores, J.; Lopez, M.C.; Ixquiac, M.

    1996-01-01

    A simple method non-solid multi monitor HAV-1 for the systematic evaluation of reactor neutron flux parameters for K o neutron activation analysis is presented. Solution of Au, Zr, Co, Zn, Sn, U and Th (deposited in filter paper) are used to study the parameters alpha and f. Dissolved Lu is used to neutron temperature (Tn) determination, according to the Wescott's formalism. A multipurpose multi monitor HAV-1 preparation, certification and evaluations presented

  7. Development of high flux thermal neutron generator for neutron activation analysis

    International Nuclear Information System (INIS)

    Vainionpaa, Jaakko H.; Chen, Allan X.; Piestrup, Melvin A.; Gary, Charles K.; Jones, Glenn; Pantell, Richard H.

    2015-01-01

    The new model DD110MB neutron generator from Adelphi Technology produces thermal (<0.5 eV) neutron flux that is normally achieved in a nuclear reactor or larger accelerator based systems. Thermal neutron fluxes of 3–5 · 10 7 n/cm 2 /s are measured. This flux is achieved using four ion beams arranged concentrically around a target chamber containing a compact moderator with a central sample cylinder. Fast neutron yield of ∼2 · 10 10 n/s is created at the titanium surface of the target chamber. The thickness and material of the moderator is selected to maximize the thermal neutron flux at the center. The 2.5 MeV neutrons are quickly thermalized to energies below 0.5 eV and concentrated at the sample cylinder. The maximum flux of thermal neutrons at the target is achieved when approximately half of the neutrons at the sample area are thermalized. In this paper we present simulation results used to characterize performance of the neutron generator. The neutron flux can be used for neutron activation analysis (NAA) prompt gamma neutron activation analysis (PGNAA) for determining the concentrations of elements in many materials. Another envisioned use of the generator is production of radioactive isotopes. DD110MB is small enough for modest-sized laboratories and universities. Compared to nuclear reactors the DD110MB produces comparable thermal flux but provides reduced administrative and safety requirements and it can be run in pulsed mode, which is beneficial in many neutron activation techniques

  8. Development of high flux thermal neutron generator for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko H., E-mail: hannes@adelphitech.com [Adelphi Technology, 2003 E Bayshore Rd, Redwood City, CA 94063 (United States); Chen, Allan X.; Piestrup, Melvin A.; Gary, Charles K. [Adelphi Technology, 2003 E Bayshore Rd, Redwood City, CA 94063 (United States); Jones, Glenn [G& J Jones Enterprice, 7486 Brighton Ct, Dublin, CA 94568 (United States); Pantell, Richard H. [Department of Electrical Engineering, Stanford University, Stanford, CA (United States)

    2015-05-01

    The new model DD110MB neutron generator from Adelphi Technology produces thermal (<0.5 eV) neutron flux that is normally achieved in a nuclear reactor or larger accelerator based systems. Thermal neutron fluxes of 3–5 · 10{sup 7} n/cm{sup 2}/s are measured. This flux is achieved using four ion beams arranged concentrically around a target chamber containing a compact moderator with a central sample cylinder. Fast neutron yield of ∼2 · 10{sup 10} n/s is created at the titanium surface of the target chamber. The thickness and material of the moderator is selected to maximize the thermal neutron flux at the center. The 2.5 MeV neutrons are quickly thermalized to energies below 0.5 eV and concentrated at the sample cylinder. The maximum flux of thermal neutrons at the target is achieved when approximately half of the neutrons at the sample area are thermalized. In this paper we present simulation results used to characterize performance of the neutron generator. The neutron flux can be used for neutron activation analysis (NAA) prompt gamma neutron activation analysis (PGNAA) for determining the concentrations of elements in many materials. Another envisioned use of the generator is production of radioactive isotopes. DD110MB is small enough for modest-sized laboratories and universities. Compared to nuclear reactors the DD110MB produces comparable thermal flux but provides reduced administrative and safety requirements and it can be run in pulsed mode, which is beneficial in many neutron activation techniques.

  9. Neutron flux optimization in irradiation channels at NUR research reactor

    International Nuclear Information System (INIS)

    Meftah, B.; Zidi, T.; Bousbia-Salah, A.

    2006-01-01

    Optimization of neutron fluxes in experimental channels is of great concern in research reactor utilization. The general approach used at the NUR research reactor for neutron flux optimization in irradiation channels is presented. The approach is essentially based upon a judicious optimization of the core configuration combined with the improvement of reflector characteristics. The method allowed to increase the thermal neutron flux for radioisotope production purposes by more than 800%. Increases of up to 60% are also observed in levels of useful fluxes available for neutron diffraction experiments (small angle neutron scattering (SANS), neutron reflectometry, etc.). Such improvements in the neutronic characteristics of the NUR reactor opened new perspectives in terms of its utilization. More particularly, it is now possible to produce at industrial scales major radio-isotopes for medicine and industry and to perform, for the first time, material testing experiments. The cost of the irradiations in the optimized configuration is generally small when compared to those performed in the old configuration and an average reduction factor of about of 10 is expected in the case of production of Molybdenum-99 (isotope required for the manufacturing of Technetium-99 medical kits). In addition to these important results, safety analysis studies showed that the more symmetrical nature of the core geometry leads to a more adequately balanced reactivity control system and contributes quite efficiently to the operational safety of the NUR reactor. Results of comparisons between calculations and measurements for a series of parameters of importance in reactor operation and safety showed good agreement

  10. Mars: The Terra Arabia Low Epithermal Neutron Flux Anomaly

    Science.gov (United States)

    Basilevsky, A. T.; Rodin, A. V.; Kozyrev, A. S.; Mitrofanov, I. G.; Neukum, G.; Werner, S. C.; Head, J. W.; Boynton, W.; Saunders, R. S.

    2004-01-01

    The High Energy Neutron Spectrometer (HEND) and Neutron Specrometer, part of the Mars Odyssey Gamma Ray Spectrometer suite of instruments, measured anomalously low epithermal neutron flux in two low-latitude areas, Terra Arabia and SW of Olympus Mons (SWOM). The low epithermal neutron flux, an indirect measure of Hydrogen abundance, is indicative of relatively high water content (in this case up to 8 mass percent) in the upper 1-2 m of the surface layer. The epithermal flux within the 60 degree latitude zone does not correlate with bedrock geology or topography but partially correlates (for Arabia) with thermal inertia. According to theoretical estimates for the current geologic epoch, ground ice should not be stable at this depth at these low latitudes so it was concluded that the anomalies are due to the presence of chemically bound water (e.g. clays, hydroxides or hydrosalts). Fast neutron flux, which is indicative of the presence of water at 20-30 cm depth, does not correlate in this latitude zone with the epithermal neutron flux. As a further step of the analysis a geotraverse including study of 152 high resolution MOC images within the Arabia anomaly was done by to find out if the area inside the anomaly differs from the neighboring areas by the presence of fluvial channels and layered deposits (possible links to chemically bound water) or in thickness and apparent texture of the surface layer. No differences were found.

  11. Neutron flux assessment of a neutron irradiation facility based on inertial electrostatic confinement fusion.

    Science.gov (United States)

    Sztejnberg Gonçalves-Carralves, M L; Miller, M E

    2015-12-01

    Neutron generators based on inertial electrostatic confinement fusion were considered for the design of a neutron irradiation facility for explanted organ Boron Neutron Capture Therapy (BNCT) that could be installed in a health care center as well as in research areas. The chosen facility configuration is "irradiation chamber", a ~20×20×40 cm(3) cavity near or in the center of the facility geometry where samples to be irradiated can be placed. Neutron flux calculations were performed to study different manners for improving scattering processes and, consequently, optimize neutron flux in the irradiation position. Flux distributions were assessed through numerical simulations of several models implemented in MCNP5 particle transport code. Simulation results provided a wide spectrum of combinations of net fluxes and energy spectrum distributions. Among them one can find a group that can provide thermal neutron fluxes per unit of production rate in a range from 4.1·10(-4) cm(-2) to 1.6·10(-3) cm(-2) with epithermal-to-thermal ratios between 0.3% and 13% and fast-to-thermal ratios between 0.01% to 8%. Neutron generators could be built to provide more than 10(10) n s(-1) and, consequently, with an arrangement of several generators appropriate enough neutron fluxes could be obtained that would be useful for several BNCT-related irradiations and, eventually, for clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium-Beryllium source

    Energy Technology Data Exchange (ETDEWEB)

    Didi, Abdessamad; Dadouch, Ahmed; Tajmouati, Jaouad; Bekkouri, Hassane [Advanced Technology and Integration System, Dept. of Physics, Faculty of Science Dhar Mehraz, University Sidi Mohamed Ben Abdellah, Fez (Morocco); Jai, Otman [Laboratory of Radiation and Nuclear Systems, Dept. of Physics, Faculty of Sciences, Tetouan (Morocco)

    2017-06-15

    Americium–beryllium (Am-Be; n, γ) is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci), yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: primarily, it will help us perform neutron activation analysis. Next, it will give us the opportunity to produce radio-elements with short half-lives. Am-Be single and multisource (5 sources) experiments were performed within an irradiation facility with a paraffin moderator. The resulting models mainly increase the thermal neutron flux compared to the traditional method with water moderator.

  13. Determination of spallation neutron flux through spectral adjustment techniques

    Science.gov (United States)

    Mosby, M. A.; Engle, J. W.; Jackman, K. R.; Nortier, F. M.; Birnbaum, E. R.

    2016-08-01

    The Los Alamos Isotope Production Facility (IPF) creates medical isotopes using a proton beam impinged on a target stack. Spallation neutrons are created in the interaction of the beam with target. The use of these spallation neutrons to produce additional radionuclides has been proposed. However, the energy distribution and magnitude of the flux is not well understood. A modified SAND-II spectral adjustment routine has been used with radioactivation foils to determine the differential neutron fluence for these spallation neutrons during a standard IPF production run.

  14. Determination of spallation neutron flux through spectral adjustment techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mosby, M.A., E-mail: mosbym@lanl.gov; Engle, J.W.; Jackman, K.R.; Nortier, F.M.; Birnbaum, E.R.

    2016-08-15

    The Los Alamos Isotope Production Facility (IPF) creates medical isotopes using a proton beam impinged on a target stack. Spallation neutrons are created in the interaction of the beam with target. The use of these spallation neutrons to produce additional radionuclides has been proposed. However, the energy distribution and magnitude of the flux is not well understood. A modified SAND-II spectral adjustment routine has been used with radioactivation foils to determine the differential neutron fluence for these spallation neutrons during a standard IPF production run.

  15. Verification of MCNP simulation of neutron flux parameters at TRIGA MK II reactor of Malaysia

    International Nuclear Information System (INIS)

    Yavar, A.R.; Khalafi, H.; Kasesaz, Y.; Sarmani, S.; Yahaya, R.; Wood, A.K.; Khoo, K.S.

    2012-01-01

    A 3-D model for 1 MW TRIGA Mark II research reactor was simulated. Neutron flux parameters were calculated using MCNP-4C code and were compared with experimental results obtained by k 0 -INAA and absolute method. The average values of φ th ,φ epi , and φ fast by MCNP code were (2.19±0.03)×10 12 cm −2 s −1 , (1.26±0.02)×10 11 cm −2 s −1 and (3.33±0.02)×10 10 cm −2 s −1 , respectively. These average values were consistent with the experimental results obtained by k 0 -INAA. The findings show a good agreement between MCNP code results and experimental results. - Highlights: ► We use 3-D neutronic model to enhance the utilization of the economical use of reactor.► The MCNP code is modified to analyze the neutronic parameters. ► The neutron flux distributions are homogeneous and consistent with experimental results. ► A complete simulation of the calculated neutron flux parameters in 40 RR irradiation channels is achieved.

  16. Accounting for the thermal neutron flux depression in voluminous samples for instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Overwater, R.M.W.; Hoogenboom, J.E.

    1994-01-01

    At the Delft University of Technology Interfaculty Reactor Institute, a facility has been installed to irradiate cylindrical samples with diameters up to 15 cm and weights up to 50 kg for instrumental neutron activation analysis (INAA) purposes. To be able to do quantitative INAA on voluminous samples, it is necessary to correct for gamma-ray absorption, gamma-ray scattering, neutron absorption, and neutron scattering in the sample. The neutron absorption and the neutron scattering are discussed. An analytical solution is obtained for the diffusion equation in the geometry of the irradiation facility. For samples with known composition, the neutron flux--as a function of position in the sample--can be calculated directly. Those of unknown composition require additional flux measurements on which least-squares fitting must be done to obtain both the thermal neutron diffusion coefficient D s and the diffusion length L s of the sample. Experiments are performed to test the theory

  17. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium Beryllium source

    OpenAIRE

    Didi, Abdessamad; Dadouch, A.; Jaï, O.; Tajmouati, J.; El Bekkouri, H.

    2017-01-01

    Americium–beryllium (Am-Be; n, γ) is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci), yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: pr...

  18. Distribution of thermal neutron flux around a PET cyclotron.

    Science.gov (United States)

    Ogata, Yoshimune; Ishigure, Nobuhito; Mochizuki, Shingo; Ito, Kengo; Hatano, Kentaro; Abe, Junichiro; Miyahara, Hiroshi; Masumoto, Kazuyoshi; Nakamura, Hajime

    2011-05-01

    The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 10(6) cm(-2) s(-1) and 1.7 × 10(6) cm(-2) s(-1) during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 10(5) cm(-2) s(-1) and 1.2 × 10(5) cm(-2) s(-1), respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm s, which corresponded to 0.1 μSv h(-1) in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit.

  19. Experimental evaluation of the neutrons flux of a irradiator with AmBe sources and its possibility of use in materials analysis

    International Nuclear Information System (INIS)

    Lima, Ruy Barros de

    2003-01-01

    This work had as a target to determine the irradiator thermal and over cadmium (epithermal and fast) neutrons flux , of the Nuclear Experimental Laboratory of the Nuclear Energy Center (CNEN) - IPEN, and the possibility of its use for Neutron Activation Analysis (NAA) by the absolute method. The neutrons flux quantification was performed indirectly by the gold naked and cadmium-covered foils activation technique. The neutrons flux was determined for two situations: with polyethylene block 5.0 cm thick and without the polyethylene block. The quantification of the elements present in the irradiated samples was obtained after the experimental determination of the incident neutrons flux in the irradiation position of the sample. Flux values along the irradiator axis were determined. Some materials were analyzed, presenting good agreement with reference values. (author)

  20. Self-powered neutron and gamma-ray flux detector

    International Nuclear Information System (INIS)

    Allan, C.J.; Shields, R.B.; Lynch, G.F.; Cuttler, J.M.

    1980-01-01

    A new type of self-powered neutron detector was developed which is sensitive to both the neutron and gamma-ray fluxes. The emitter comprises two parts. The central emitter core is made of materials that generate high-energy electrons on exposure to neutrons. The outer layer acts as a gamma-ray/electron converter, and since it has a higher atomic number and higher back-scattering coefficient than the collector, increases the net outflow or emmission of electrons. The collector, which is around the emitter outer layer, is insulated from the outer layer electrically with dielectric insulation formed from compressed metal-oxide powder. The fraction of electrons given off by the emitter that is reflected back by the collector is less than the fraction of electrons emitted by the collector that is reflected back by the emitter. The thickness of the outer layer needed to achieve this result is very small. A detector of this design responds to external reactor gamma-rays as well as to neutron capture gamma-rays from the collector. The emitter core is either nickel, iron or titanium, or alloys based on these metals. The outer layer is made of platinum, tantalum, osmium, molybdenum or cerium. The detector is particularly useful for monitoring neutron and gamma ray flux intensities in nuclear reactor cores in which the neutron and gamma ray flux intensities are closely proportional, are unltimately related to the fission rate, and are used as measurements of nuclear reactor power. (DN)

  1. Absolute measurement of the 242Pu neutron-capture cross section

    Science.gov (United States)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.; Dance Collaboration

    2016-04-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. The first direct measurement of the 242Pu(n ,γ ) cross section was made over the incident neutron energy range from thermal to ≈6 keV, and the absolute scale of the (n ,γ ) cross section was set according to the known 239Pu(n ,f ) resonance at En ,R=7.83 eV. This was accomplished by adding a small quantity of 239Pu to the 242Pu sample. The relative scale of the cross section, with a range of four orders of magnitude, was determined for incident neutron energies from thermal to ≈40 keV. Our data, in general, are in agreement with previous measurements and those reported in ENDF/B-VII.1; the 242Pu(n ,γ ) cross section at the En ,R=2.68 eV resonance is within 2.4 % of the evaluated value. However, discrepancies exist at higher energies; our data are ≈30 % lower than the evaluated data at En≈1 keV and are approximately 2 σ away from the previous measurement at En≈20 keV.

  2. Calculation of neutron flux in the presence of a source

    International Nuclear Information System (INIS)

    Planchard, J.

    1993-09-01

    Neutron sources are introduced into the reactors to initiate the chain reaction. For safety reasons, we have to know the distribution and evolution of the flux throughout the startup phase. The flux is calculated iteratively but convergence of the process can slow down arbitrarily as we approach criticality. A calculation method is presented, with a convergence speed which does not depend on the negative reactivity when it is small. (author). 7 refs

  3. An investigation of epithermal neutron fluxes from lunar impact basins

    Science.gov (United States)

    Sinitsyn, M. P.

    2016-12-01

    The article presents the distribution of epithermal neutron fluxes and hydrogen contents in lunar impact basins and mare formations across the entire equatorial lunar surface. A distribution of a suppression factor of epithermal neutron flux in seleno-graphic longitude has been obtained. As a result of the distribution it may be concluded that the suppression factor (a degree of neutron flux reduction relative to a maximum,located near crater Tycho) has the highest value in the near side marine basins. In the same places the largest amount of hydrogen is contained. In contrast, the lower hydrogen contents and, accordingly, the minimum neutron suppression factors correspond to the mare formations and impact basins on the far side. So, suppression of epithermal neutrons is almost completely absent in the mare Moscoviense. Therefore, the corresponding concentration of hydrogen is also rather insignificant there. Additionally, the results presented here indicate that the concentration of hydrogen is a very complicated function of age (maturity) of the lunar surface. This in turn points to the lack of a gradual accumulation of hydrogen with time over a period of several million years or more. Taking into account that the age of the far side impact basins of the Moon is, in general, more than the age of the same near side objects, it is possible to assume indigenous origin of the hydrogen in marine lavas.

  4. Review of unfolding methods for neutron flux dosimetry

    International Nuclear Information System (INIS)

    Stallmann, F.W.; Kam, F.B.K.

    1975-01-01

    The primary method in reactor dosimetry is the foil activation technique. To translate the activation measurements into neutron fluxes, a special data processing technique called unfolding is needed. Some general observations about the problems and the reliability of this approach to reactor dosimetry are presented. Current unfolding methods are reviewed. 12 references. (auth)

  5. Neutron scattering from an imperfect flux-line lattice

    International Nuclear Information System (INIS)

    Brandt, E.H.

    1978-01-01

    The diffraction of neutrons from the imperfect vortex lattice of a type-II superconductor is investigated. It is found that flux pinning leads not only to a broadening of the Bragg reflections but also to diffuse scattering into the first Brillouin zone, which at high fields exceeds Bragg scattering

  6. Flux-Vortex Pinning and Neutron Star Evolution

    Indian Academy of Sciences (India)

    M. Ali Alpar

    Flux-Vortex Pinning and Neutron Star Evolution. M. ALI ALPAR. Faculty of Engineering and Natural Sciences, Sabancı University, 34956, Istanbul, Turkey. E-mail: alpar@sabanciuniv.edu. MS received 22 May 2017; accepted 24 July 2017; published online 12 September 2017. Abstract. G. Srinivasan et al. (1990) proposed ...

  7. Study of the neutron flux distribution in acylindrical reactor

    Directory of Open Access Journals (Sweden)

    A. Vidal-Ferràndiz

    2017-08-01

    Full Text Available In the Energy Engineering Degree of the Universitat Politècnica de València, the students attend to the Nuclear Technology course, in which the basic knowledge of this technology is presented. A main objective of this technology is to obtain neutron population distribution inside a reactor core, in order to maintain the fission reaction chain. As this activity cannot be experimentally developed, mathematical modelling is of great importance to achieve such objective.  One of the computer laboratories proposed consists in the neutron flux determination analytically and numerically in a cylindrical geometry. The analytical solution makes use of the Bessel functions and is a good example of their applications. Alternatively, a numerical solution based on finite differences is used to obtain an approximate solution of the neutron flux. In this work, different discretizations of the cylindrical geometry are implemented and their results are compared.

  8. Methods and applications in high flux neutron imaging

    International Nuclear Information System (INIS)

    Ballhausen, H.

    2007-01-01

    This treatise develops new methods for high flux neutron radiography and high flux neutron tomography and describes some of their applications in actual experiments. Instead of single images, time series can be acquired with short exposure times due to the available high intensity. To best use the increased amount of information, new estimators are proposed, which extract accurate results from the recorded ensembles, even if the individual piece of data is very noisy and in addition severely affected by systematic errors such as an influence of gamma background radiation. The spatial resolution of neutron radiographies, usually limited by beam divergence and inherent resolution of the scintillator, can be significantly increased by scanning the sample with a pinhole-micro-collimator. This technique circumvents any limitations in present detector design and, due to the available high intensity, could be successfully tested. Imaging with scattered neutrons as opposed to conventional total attenuation based imaging determines separately the absorption and scattering cross sections within the sample. For the first time even coherent angle dependent scattering could be visualized space-resolved. New applications of high flux neutron imaging are presented, such as materials engineering experiments on innovative metal joints, time-resolved tomography on multilayer stacks of fuel cells under operation, and others. A new implementation of an algorithm for the algebraic reconstruction of tomography data executes even in case of missing information, such as limited angle tomography, and returns quantitative reconstructions. The setup of the world-leading high flux radiography and tomography facility at the Institut Laue-Langevin is presented. A comprehensive appendix covers the physical and technical foundations of neutron imaging. (orig.)

  9. Traceable Determination of the Absolute Neutron Emission Yields of UO2F2 Working Reference Materials

    International Nuclear Information System (INIS)

    LaFleur, A.M.; Swinhoe, M.T.; Mayo, D.R.; Sapp, B.A.; Croft, S.; Mayer, R.L.

    2013-06-01

    The nuclear material contained in the process equipment of a uranium enrichment plant (referred to as holdup) is an important component of the overall nuclear material inventory for the plant. Accurate quantification and verification of holdup is needed to improve international safeguards and nuclear material accountancy. This is also needed for criticality safety and waste disposition. Passive neutron and gamma-ray nondestructive assay (NDA) methods are used to measure the holdup in process equipment. A key advantage of neutron measurements is that neutrons are highly penetrating and can be measured through thick walled equipment. The dominant source of neutrons in the UO 2 F 2 holdup is from the 19 F(α, n) 22 Na reaction resulting from 234 U alpha decay when uranium is enriched. There is a considerable spread between different historic determinations of the 19 F(α, n) yield from uranium which limits the accuracy of modeling and the calibration of NDA instruments. Furthermore, the compound form and presence of water also significantly affects the neutron emission rate from the holdup. This paper describes a series of experimental measurements performed at Los Alamos National Laboratory (LANL) to determine the absolute neutron emission yield from 10 different UO 2 F 2 working reference materials (WRMs) fabricated at the Portsmouth Gaseous Diffusion Plant (PGDP). The Mini Epithermal Neutron Multiplicity Counter (Mini ENMC) and a NIST certified 252 Cf neutron source were used for these measurements. The high efficiency and short die-away time of the Mini ENMC provides the high measurement precision needed to certify the neutron emission yield. The experiment was designed to achieve sub 1% accuracy in the net counting rate on each item and to provide assurance that important factors such as instrument stability, item placement and background were well understood. The traceable neutron yields measured from the WRMs were used to determine a more accurate neutron yield

  10. Green's function approach to neutron flux discontinuities

    International Nuclear Information System (INIS)

    Saad, E.A.; El-Wakil, S.A.

    1980-01-01

    The present work is devoted to the presentation of analytical method for the calculation of elastically and inelastically slowed down neutrons in an infinite non-absorbing medium. On the basis of the central limit theory (CLT) and the integral transform technique the slowing down equation including inelastic scattering, in terms of the Green function of elastic scattering, is solved. The Green function is decomposed according to the number of collisions. Placzec discontinuity associated with elastic scattering in addition to two discontinuities due to inelastic scattering are investigated. Numerical calculations for Fe 56 show that the elastic discontinuity produces about 41.8% change in the collision density whilst the ratio of the inelastic collision density discontinuity at qsub(o)sup(+) to the Placzec discontinuity at usub(o) + 1n 1/oc gives 55.7 percent change. (author)

  11. Analysis of neutron flux measurement systems using statistical functions

    International Nuclear Information System (INIS)

    Pontes, Eduardo Winston

    1997-01-01

    This work develops an integrated analysis for neutron flux measurement systems using the concepts of cumulants and spectra. Its major contribution is the generalization of Campbell's theorem in the form of spectra in the frequency domain, and its application to the analysis of neutron flux measurement systems. Campbell's theorem, in its generalized form, constitutes an important tool, not only to find the nth-order frequency spectra of the radiation detector, but also in the system analysis. The radiation detector, an ionization chamber for neutrons, is modeled for cylindrical, plane and spherical geometries. The detector current pulses are characterized by a vector of random parameters, and the associated charges, statistical moments and frequency spectra of the resulting current are calculated. A computer program is developed for application of the proposed methodology. In order for the analysis to integrate the associated electronics, the signal processor is studied, considering analog and digital configurations. The analysis is unified by developing the concept of equivalent systems that can be used to describe the cumulants and spectra in analog or digital systems. The noise in the signal processor input stage is analysed in terms of second order spectrum. Mathematical expressions are presented for cumulants and spectra up to fourth order, for important cases of filter positioning relative to detector spectra. Unbiased conventional estimators for cumulants are used, and, to evaluate systems precision and response time, expressions are developed for their variances. Finally, some possibilities for obtaining neutron radiation flux as a function of cumulants are discussed. In summary, this work proposes some analysis tools which make possible important decisions in the design of better neutron flux measurement systems. (author)

  12. Absolute efficiency calibration of 6LiF-based solid state thermal neutron detectors

    Science.gov (United States)

    Finocchiaro, Paolo; Cosentino, Luigi; Lo Meo, Sergio; Nolte, Ralf; Radeck, Desiree

    2018-03-01

    The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of a promising low-cost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. A few configurations were studied with the GEANT4 simulation code, and the intrinsic efficiency of the corresponding detectors was calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured intrinsic detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.

  13. Pure commercial gold foils as neutron flux monitor: Neutron self-shielding assessment

    International Nuclear Information System (INIS)

    Haddad, Kh.; Haj-Hassan, H.; Helal, W.

    2007-01-01

    An assessment of pure commercial (99.9%) gold foils as neutron flux monitor was performed. A thin foils of pure commercial gold were prepared as an in-house reference material for neutron flux measurement. The assessed foils are available commercially and its cost is much less than the certified ones. Determination of the neutron self-shielding factors in these foils for both thermal and epithermal neutrons have been done experimentally. These foils show good results repeatability and good agreement with certified activation monitors. According to the well-known physical constants of the nuclide and its low cost comparing with certified foils, it can be used as an in-house reference monitor

  14. On the absolute calibration of a DT fusion neutron yield diagnostic

    Directory of Open Access Journals (Sweden)

    Ruiz C.L.

    2013-11-01

    Full Text Available Recent advances in Inertial Confinement Fusion (ICF experiments at Lawrence Livermore National Laboratory's National Ignition Facility (NIF have underscored the need for accurate total yield measurements of DT neutrons because yield measurements provide a measure of the predicted performance of the experiments. Future gas-puff DT experiments at Sandia National Laboratory's Z facility will also require similar measurements. For ICF DT experiments, the standard technique for measuring the neutron (14.1 MeV yield, counts the activity (counts/minute induced in irradiated copper samples. This activity occurs by the 63Cu(n,2n62Cu reaction where 62Cu decays by positrons (β+ with a half-life of 9.67 minutes. The calibrations discussed here employ the associated-particle method (APM, where the α (4He particles from the T(d,n4He reaction are measured to infer neutron fluxes on a copper sample. The flux induces 62Cu activity, measured in a coincidence counting system. The method leads to a relationship between a DT neutron yield and copper activity known as the F-factor. The goal in future experiments is to apply this calibration to measure the yield at NIF with a combined uncertainty approaching 5%.

  15. Stability of interlinked neutron vortex and proton flux tube arrays in a neutron star: equilibrium configurations

    Science.gov (United States)

    Drummond, L. V.; Melatos, A.

    2017-12-01

    Three-dimensional, Gross-Pitaevskii equation (GPE) simulations are presented of the interaction between neutron superfluid vortices and proton superconductor flux tubes in a rotating, harmonic trap, representing an idealized model of the outer core of a neutron star. Low-energy states of the neutron condensate are calculated by evolving the GPE in imaginary time in the presence of a prescribed, static, rectilinear flux tube array. The calculations are carried out as a function of the angle between the global magnetic and rotation axes, and the amplitude and sign of the current-current and density couplings between the neutron and proton condensates. It is found that the system is frustrated by the competition between vortex-vortex repulsion and vortex-flux-tube attraction (pinning), leading to the formation of vortex tangles and 'glassy' behaviour characterized by multiple metastable states spaced closely in energy. The dimensionless parameters in the simulations are ordered as one expects in a neutron star, but the dynamic range is many orders of magnitude smaller than in reality, so caution must be exercised when assessing the astrophysical implications. Nevertheless, the results suggest that tangled vorticity may be endemic in neutron star outer cores.

  16. Validation of Numerical Simulations of Activation by Neutron Flux

    International Nuclear Information System (INIS)

    Janski, Sylvain

    2016-01-01

    The knowledge of the radionuclide content of radioactive waste is of utmost importance for safety and waste management reasons. Numerical simulations are used at EDF-CIDEN to anticipate the dismantling and the radioactive waste management. The activation scheme by neutron flux developed at EDF-CIDEN comprises four steps: Step 1: Computing of a 3 dimensional multigroup neutron flux map. The mapping of the neutron flux is obtained on the basis of a neutron propagation calculation. The codes used are MCNP reference or TRIPOLI reference. Both solve the transport equation called the Boltzmann equation. The input data covers the microscopic cross-sections, the 3 dimensional geometry, the chemical compositions with no impurities and the computed neutron sources resulting in the neutrons emitted by the fuel assemblies. The neutron flux map is calculated at the nominal power rating conditions, and each flux is homogenized in a limited number of energy groups. Step 2: Calculation of the activities. The activities are calculated for each component or sub-component of interest. The code used is DARWIN-PEPIN (developed by the French CEA). It solves a system of Bateman equations. The input data covers the 3-dimensional neutron flux map calculated in step one, the microscopic cross sections, the radioactive decay series associated with the radioactive half-lives, the chemical compositions with impurities, and the history of irradiation resulting in the daily power production. The output data is the radioactive inventory of each component or sub-component of interest limited to a list of 143 radionuclides. Step 3: Waste classification. According to the radioactive inventory of each component or sub-component, and the waste classification criteria, a waste classification can be made. Basically the criteria are based on the levels of specific activity and radiotoxicity of 143 radionuclides. The distinction between the 'Long Life' and the 'Short Life' waste is

  17. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  18. Optimization of neutron flux distribution in Isotope Production Reactor

    International Nuclear Information System (INIS)

    Valladares, G.L.

    1988-01-01

    In order to optimize the thermal neutrons flux distribution in a Radioisotope Production and Research Reactor, the influence of two reactor parameters was studied, namely the Vmod / Vcomb ratio and the core volume. The reactor core is built with uranium oxide pellets (UO 2 ) mounted in rod clusters, with an enrichment level of ∼3 %, similar to LIGHT WATER POWER REATOR (LWR) fuel elements. (author) [pt

  19. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Johnson, M Gatu; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Magoon, J; Meyerhofer, D D; Sangster, T C; Shoup, M; Ulreich, J; Ashabranner, R C; Bionta, R M; Carpenter, A C; Felker, B; Khater, H Y; LePape, S; MacKinnon, A; McKernan, M A; Moran, M; Rygg, J R; Yeoman, M F; Zacharias, R; Leeper, R J; Fletcher, K; Farrell, M; Jasion, D; Kilkenny, J; Paguio, R

    2013-04-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  20. An alternative model for neutron flux maximization in research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Teruel, F.E.; Rizwan, Uddin [Illinois Univ. at Urbana-Champaign, Urbana, IL (United States)

    2005-07-01

    We present a core design for a new research reactor. The desired characteristics in this pool type research reactor of 10 MW power are: high thermal neutron fluxes, plenty of space to locate facilities in the reflector and an acceptable life cycle. In addition, the design is limited to standard fuel material of low enrichment uranium. Following the design of the German research reactor, FRM-II, which delivers high thermal neutron fluxes, an asymmetric cylindrical core with an inner and outer reflector is developed. This design concept analyzed using MCNP and ORIGEN2, achieves the desired features and allows further improvement. The final design is conservatively characterized by a life cycle of 41 days, a maximum thermal neutron flux peak in the reflector of 3.9 E 14 n.cm{sup -2} s{sup -1} and plenty of space to locate facilities and irradiate materials in the outer and inner reflector. This design may be used as a base for further development. (authors)

  1. High-accuracy determination of the neutron flux in the new experimental area nTOF-EAR2 at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Sabate-Gilarte, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Barbagallo, M.; Colonna, N.; Damone, L.; Belloni, F.; Mastromarco, M.; Tagliente, G.; Variale, V. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Bari (Italy); Gunsing, F.; Berthoumieux, E.; Diakaki, M.; Papaevangelou, T.; Dupont, E. [Universite Paris-Saclay, CEA Irfu, Gif-sur-Yvette (France); Zugec, P.; Bosnar, D. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Vlachoudis, V.; Aberle, O.; Brugger, M.; Calviani, M.; Cardella, R.; Cerutti, F.; Chiaveri, E.; Ferrari, A.; Kadi, Y.; Losito, R.; Macina, D.; Montesano, S.; Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Chen, Y.H.; Audouin, L.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Stamatopoulos, A.; Kokkoris, M.; Tsinganis, A.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Lerendegui-Marco, J.; Cortes-Giraldo, M.A.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Villacorta, A. [University of Salamanca, Salamanca (Spain); Cosentino, L.; Finocchiaro, P.; Piscopo, M. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Musumarra, A. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Universita di Catania, Dipartimento di Fisica, Catania (Italy); Andrzejewski, J.; Gawlik, A.; Marganiec, J.; Perkowski, J. [University of Lodz, Lodz (Poland); Becares, V.; Balibrea, J.; Cano-Ott, D.; Garcia, A.R.; Gonzalez, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Bacak, M.; Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Technische Universitaet Wien, Wien (Austria); Baccomi, R.; Milazzo, P.M. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (Italy); Barros, S.; Ferreira, P.; Goncalves, I.F.; Vaz, P. [Instituto Superior Tecnico, Lisbon (Portugal); Becvar, F.; Krticka, M.; Valenta, S. [Charles University, Prague (Czech Republic); Beinrucker, C.; Goebel, K.; Heftrich, T.; Reifarth, R.; Schmidt, S.; Weigand, M.; Wolf, C. [Goethe University Frankfurt, Frankfurt (Germany); Billowes, J.; Frost, R.J.W.; Ryan, J.A.; Smith, A.G.; Warren, S.; Wright, T. [University of Manchester, Manchester (United Kingdom); Caamano, M.; Deo, K.; Duran, I.; Fernandez-Dominguez, B.; Leal-Cidoncha, E.; Paradela, C.; Robles, M.S. [University of Santiago de Compostela, Santiago de Compostela (Spain); Calvino, F.; Casanovas, A.; Riego-Perez, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Castelluccio, D.M.; Lo Meo, S. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (Italy); Cortes, G.; Mengoni, A. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Domingo-Pardo, C.; Tain, J.L. [Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Heinitz, S.; Kivel, N.; Maugeri, E.A.; Schumann, D. [Paul Scherrer Institut (PSI), Villingen (Switzerland); Furman, V.; Sedyshev, P. [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation); Gheorghe, I.; Glodariu, T.; Mirea, M.; Oprea, A. [Horia Hulubei National Institute of Physics and Nuclear Engineering, Magurele (Romania); Goverdovski, A.; Ketlerov, V.; Khryachkov, V. [Institute of Physics and Power Engineering (IPPE), Obninsk (Russian Federation); Griesmayer, E.; Jericha, E.; Kavrigin, P.; Leeb, H. [Technische Universitaet Wien, Wien (Austria); Harada, H.; Kimura, A. [Japan Atomic Energy Agency (JAEA), Tokai-mura (Japan); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Heyse, J.; Schillebeeckx, P. [European Commission, Joint Research Centre, Geel (BE); Jenkins, D.G. [University of York, York (GB); Kaeppeler, F. [Karlsruhe Institute of Technology, Karlsruhe (DE); Katabuchi, T. [Tokyo Institute of Technology, Tokyo (JP); Lederer, C.; Lonsdale, S.J.; Woods, P.J. [University of Edinburgh, School of Physics and Astronomy, Edinburgh (GB); Licata, M.; Massimi, C.; Vannini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT); Mastinu, P. [Istituto Nazionale di Fisica Nucleare, Sezione di Legnaro, Legnaro (IT); Matteucci, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (IT); Universita di Trieste, Dipartimento di Astronomia, Trieste (IT); Mingrone, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Nolte, R. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (DE); Palomo-Pinto, F.R. [Universidad de Sevilla, Dept. Ingenieria Electronica, Escuela Tecnica Superior de Ingenieros, Sevilla (ES); Patronis, N. [University of Ioannina, Ioannina (GR); Pavlik, A. [University of Vienna, Faculty of Physics, Vienna (AT); Porras, J.I. [University of Granada, Granada (ES); Praena, J. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (ES); University of Granada, Granada (ES); Rajeev, K.; Rout, P.C.; Saxena, A.; Suryanarayana, S.V. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Rauscher, T. [University of Hertfordshire, Centre for Astrophysics Research, Hatfield (GB); University of Basel, Department of Physics, Basel (CH); Tarifeno-Saldivia, A. [Universitat Politecnica de Catalunya, Barcelona (ES); Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (ES); Ventura, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Wallner, A. [Australian National University, Canberra (AU)

    2017-10-15

    A new high flux experimental area has recently become operational at the nTOF facility at CERN. This new measuring station, nTOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20 m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2 meV to 100 MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the nTOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with {sup 197}Au foils in the beam. (orig.)

  2. High-accuracy determination of the neutron flux in the new experimental area n_TOF-EAR2 at CERN

    Science.gov (United States)

    Sabaté-Gilarte, M.; Barbagallo, M.; Colonna, N.; Gunsing, F.; Žugec, P.; Vlachoudis, V.; Chen, Y. H.; Stamatopoulos, A.; Lerendegui-Marco, J.; Cortés-Giraldo, M. A.; Villacorta, A.; Guerrero, C.; Damone, L.; Audouin, L.; Berthoumieux, E.; Cosentino, L.; Diakaki, M.; Finocchiaro, P.; Musumarra, A.; Papaevangelou, T.; Piscopo, M.; Tassan-Got, L.; Aberle, O.; Andrzejewski, J.; Bécares, V.; Bacak, M.; Baccomi, R.; Balibrea, J.; Barros, S.; Bečvář, F.; Beinrucker, C.; Belloni, F.; Billowes, J.; Bosnar, D.; Brugger, M.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Castelluccio, D. M.; Cerutti, F.; Chiaveri, E.; Cortés, G.; Deo, K.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Frost, R. J. W.; Furman, V.; Göbel, K.; García, A. R.; Gawlik, A.; Gheorghe, I.; Glodariu, T.; Gonçalves, I. F.; González, E.; Goverdovski, A.; Griesmayer, E.; Harada, H.; Heftrich, T.; Heinitz, S.; Hernández-Prieto, A.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Katabuchi, T.; Kavrigin, P.; Ketlerov, V.; Khryachkov, V.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Licata, M.; Lo Meo, S.; Lonsdale, S. J.; Losito, R.; Macina, D.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Montesano, S.; Nolte, R.; Oprea, A.; Palomo-Pinto, F. R.; Paradela, C.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, J. I.; Praena, J.; Quesada, J. M.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M. S.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Smith, A. G.; Suryanarayana, S. V.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlastou, R.; Wallner, A.; Warren, S.; Weigand, M.; Wolf, C.; Woods, P. J.; Weiss, C.; Wright, T.

    2017-10-01

    A new high flux experimental area has recently become operational at the n_TOF facility at CERN. This new measuring station, n_TOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2meV to 100MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the n_TOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with 197Au foils in the beam.

  3. Fusion neutron yield and flux calculation on HT-7 superconducting tokamak

    International Nuclear Information System (INIS)

    Fu Yanzhang; Zhu Yubao; Chen Juequan

    2006-01-01

    Neutron yield and flux have been numerically estimated on HT-7 tokamak. The total fusion neutron yield and neutron flux distribution on different positions and azimuth angles of the device are presented. Analyses on the errors induced by ion temperature and density distribution factors are given in detail. The results of the calculations provide a useful database for neutron diagnostics and neutron radiation protection. (authors)

  4. Neutron scattering at the high-flux isotope reactor

    International Nuclear Information System (INIS)

    Cable, J.W. Chakoumakos, B.C.; Dai, P.

    1995-01-01

    The title facilities offer the brightest source of neutrons in the national user program. Neutron scattering experiments probe the structure and dynamics of materials in unique and complementary ways as compared to x-ray scattering methods and provide fundamental data on materials of interest to solid state physicists, chemists, biologists, polymer scientists, colloid scientists, mineralogists, and metallurgists. Instrumentation at the High- Flux Isotope Reactor includes triple-axis spectrometers for inelastic scattering experiments, a single-crystal four diffractometer for crystal structural studies, a high-resolution powder diffractometer for nuclear and magnetic structure studies, a wide-angle diffractometer for dynamic powder studies and measurements of diffuse scattering in crystals, a small-angle neutron scattering (SANS) instrument used primarily to study structure-function relationships in polymers and biological macromolecules, a neutron reflectometer for studies of surface and thin-film structures, and residual stress instrumentation for determining macro- and micro-stresses in structural metals and ceramics. Research highlights of these areas will illustrate the current state of neutron science to study the physical properties of materials

  5. Correlation of the space distribution of the neutron flux and power in the reactor RA in Vinca

    International Nuclear Information System (INIS)

    Martinc, R.; Marinkov, L.; Bikit, I.; Kocic, A.; Veskovic, M.; Zivotic, Z.

    1984-01-01

    The neutron flux distribution in the reactor RA has been measured by the neutron activation detectors Zr, Dy and Co. The correlation of the neutron flux distribution and power distribution has been established by the homogeneous approach. (author)

  6. High Flux Isotope Reactor cold neutron source reference design concept

    International Nuclear Information System (INIS)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory's (ORNL's) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH 2 ) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH 2 cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept

  7. High Flux Isotope Reactor cold neutron source reference design concept

    Energy Technology Data Exchange (ETDEWEB)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R. [and others

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  8. On Line Neutron Flux Mapping in Fuel Coolant Channels of a Research Reactor

    International Nuclear Information System (INIS)

    Barbot, Loic; Domergue, Christophe; Villard, Jean-Francois; Destouches, Christophe; Braoudakis, George; Wassink, David; Sinclair, Bradley; Osborn, John-C.; Wu, Huayou; Blandin, C.; Thevenin, Mathieu; Corre, Gwenole; Normand, Stephane

    2013-06-01

    This work deals with the on-line neutron flux mapping of the OPAL research reactor. A specific irradiation device has been set up to investigate fuel coolant channels using subminiature fission chambers to get thermal neutron flux profiles. Experimental results are compared to first neutronic calculations and show good agreement (C/E ∼0.97). (authors)

  9. Shidaowan HTR Ex-Core Neutron Flux Monitoring Systems

    International Nuclear Information System (INIS)

    Artaud, Clark J.; Yang Shuping

    2014-01-01

    For the Huaneng Shandong Shidao Bay Nuclear Power Plant High Temperature Gas-Cooled Reactor Nuclear Power Plant Demonstration Project (HTR-PM) several neutron flux measurements are made outside the Reactor Pressure Vessel (RPV) performed by the Ex-core Neutron Flux Monitoring Systems (ENFMS). This paper will discuss the design of the ENFMS for the Shidaowan project. The unique design of this ENFMS includes a B-10 proportional counter for Source Range (SR) monitoring and a shared four-section guarded fission chamber detector assembly for both Intermediate Range (IR) and Power Range (PR) monitoring. The detectors hang from a suspension shielding device via wire rope. The IR channel ENFMS is completely qualified to survive Loss of Coolant Accidents (LOCA) and Main Steam Line Breaks (MSLB) per US NRC Reg Guide 1.97 Post Monitoring Requirements. The ENFMS will be qualified for Class 1E Safety-Related applications and also will undergo EMI / EMC testing per Reg Guide 1.180. Due to the long length of the HTR-PM core, the flux is measured at several axial positions. For the fission chamber based systems full advantage is taken of all the operating modes for fission chambers (pulse counting, mean square voltage (MSV), and linear current) to provide the Intermediate and Power Range signals. This paper describes the challenges in the development of the monitoring systems for the measurement of neutron flux within the ex core region. The selection of detector configuration and the associated signal processing will be discussed and compared with traditional PWR designs. The use of only analog signal processing techniques will also be elaborated on. (author)

  10. Upgrade of the compact neutron spectrometer for high flux environments

    Science.gov (United States)

    Osipenko, M.; Bellucci, A.; Ceriale, V.; Corsini, D.; Gariano, G.; Gatti, F.; Girolami, M.; Minutoli, S.; Panza, F.; Pillon, M.; Ripani, M.; Trucchi, D. M.

    2018-03-01

    In this paper new version of the 6Li-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. New metal contacts approaching ohmic conditions were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of the signal at detector side was implemented to improve its resolution. This preamplification is based on the RF transformer not sensitive to high neutron flux. The compact mechanical design allowed to reduce detector size to a tube of 1 cm diameter and 13 cm long. The spectrometer was tested in the thermal column of TRIGA reactor and at the DD neutron generator. The test results indicate an energy resolution of 300 keV (FWHM), reduced to 72 keV (RMS) excluding energy loss, and coincidence timing resolution of 160 ps (FWHM). The measured data are in agreement with Geant4 simulations except for larger energy loss tail presumably related to imperfections of metal contacts and glue expansion.

  11. Pursuing nuclear energy with no nuclear contamination - from neutron flux reactor to deuteron flux reactor

    International Nuclear Information System (INIS)

    Li, X. Z.; Wei, Q. M.; Liu, B.; Zhu, X. G.; Ren, S. L.

    2007-01-01

    Pursuing nuclear energy with no nuclear contamination has been a long endeavor since the first fission reactor in 1942. Four major concepts have been the key issues: i.e. resonance, negative feed back, self-sustaining, nuclear radiation. When nuclear energy was just discovered in laboratory, the key issue was to enlarge it from the micro-scale to the macro-scale. Slowing-down the neutrons was the key issue to enhance the fission cross-section in order to build-up the neutron flux through the chain-reactions using resonance between neutron and fissile materials. Once the chain-reaction was realized, the negative feed-back was the key issue to keep the neutron flux at the allowable level. The negative reaction coefficient was introduced by the thermal expansion, and the resonant absorption in cadmium or boron was used to have a self-sustaining fission reactor with neutron flux. Then the strong neutron flux became the origin of all nuclear contamination, and a heavy shielding limits the application of the nuclear energy. The fusion approach to nuclear energy was much longer; nevertheless, it evolved with the similar issues. The resonance between deuteron and triton was resorted to enlarge the fusion cross section in order to keep a self-sustaining hot plasma. However, the 14 MeV neutron emission became the origin of all nuclear contamination again. Deuteron plus helium-3 fusion reaction was proposed to avoid neutron emission although there are two more difficulties: the helium-3 is supposed to be carried back from the moon; and much more higher temperature plasma has to be confined while 50 years needed to realized the deuteron-triton plasma already. Even if deuteron plus helium-3 fusion plasma might be realized in a much higher temperature plasma, we still have the neutron emission from the deuteron-deuteron fusion reaction in the deuteron plus helium-3 fusion plasma. Polarized deuteron-deuteron fusion reaction was proposed early in 1980's to select the neutron

  12. Evaluation of neutron flux in the Pool Critical Assembly

    International Nuclear Information System (INIS)

    Lippincott, E.P.; Ruddy, F.H.; Gold, R.; Kellogg, L.S.; Roberts, J.H.

    1984-09-01

    A recently completed series of experiments in the Pool Critical Assembly (PCA) at Oak Ridge National Laboratory (ORNL) provided extensive neutron flux characterization of a mockup pressure vessel configuration. Considerable effort has been made to understand the uncertainties of the various measurements made in the PCA and to resolve discrepancies in the data. Additional measurements are available for similar configurations in the Oak Ridge Reactor-Poolside Facility (ORR-PSF) at ORNL and in the NESDIP facility in the UK. Comparisons of these results, together with associated neutron field calculations, enable a better evaluation of the actual uncertainties and realistic limits of accuracy to be assessed. Such assessments are especially valuable when the accuracy improvements of benchmark referencing are to be included and extrapolations to new configurations are made

  13. The reactor neutron flux and period measure meter

    International Nuclear Information System (INIS)

    Wei Ying

    1997-11-01

    The main performance indexes of developed reactor neutron flux and period measure meter (as an intermediate range measuring instrument of nuclear instrumentation system in nuclear power plant) are introduced. The meter's function, working principle, hardware constitution, application software, and the characteristics of the meter are described. The meter adopts the advanced digital technology, it can do calculating and processing by a microprocessor to get the values of power and period. It also can give the output singles as required. The characters of the meter are high accuracy, good ability to resist disturbance, small temperature coefficient and convenient for operation, etc

  14. Neutron scattering from the flux lattice in high temperature superconductors

    International Nuclear Information System (INIS)

    Paul, D.McK.; Forgan, E.M.; Cubitt, R.; Lee, S.L.; Mook, H.A.; Timmins, P.

    1992-01-01

    Neutron scattering has been used to observe diffraction from the flux-line lattice in high temperature superconductors. This technique is particularly useful in such system as it allows observations to be made over a wide range of temperature and magnetic field. Experiments on the systems K 0.4 Ba 0.6 BiO 3 and YBa 2 Cu 3 O 7-δ will be described with applied magnetic fields of up to 4 T and for temperatures from 2 K to Tc. (orig.)

  15. Generalized diffusion theory for calculating the neutron transport scalar flux

    International Nuclear Information System (INIS)

    Alcouffe, R.E.

    1975-01-01

    A generalization of the neutron diffusion equation is introduced, the solution of which is an accurate approximation to the transport scalar flux. In this generalization the auxiliary transport calculations of the system of interest are utilized to compute an accurate, pointwise diffusion coefficient. A procedure is specified to generate and improve this auxiliary information in a systematic way, leading to improvement in the calculated diffusion scalar flux. This improvement is shown to be contingent upon satisfying the condition of positive calculated-diffusion coefficients, and an algorithm that ensures this positivity is presented. The generalized diffusion theory is also shown to be compatible with conventional diffusion theory in the sense that the same methods and codes can be used to calculate a solution for both. The accuracy of the method compared to reference S/sub N/ transport calculations is demonstrated for a wide variety of examples. (U.S.)

  16. Development of highly efficient proton recoil counter telescope for absolute measurement of neutron fluences in quasi-monoenergetic neutron calibration fields of high energy

    International Nuclear Information System (INIS)

    Shikaze, Yoshiaki; Tanimura, Yoshihiko; Saegusa, Jun; Tsutsumi, Masahiro

    2010-01-01

    Precise calibration of monitors and dosimeters for use with high energy neutrons necessitates reliable and accurate neutron fluences being evaluated with use of a reference point. A highly efficient Proton Recoil counter Telescope (PRT) to make absolute measurements with use of a reference point was developed to evaluate neutron fluences in quasi-monoenergetic neutron fields. The relatively large design of the PRT componentry and relatively thick, approximately 2 mm, polyethylene converter contributed to high detection efficiency at the reference point over a large irradiation area at a long distance from the target. The polyethylene converter thickness was adjusted to maintain the same carbon density per unit area as the graphite converter for easy background subtraction. The high detection efficiency and thickness adjustment resulted in efficient absolute measurements being made of the neutron fluences of sufficient statistical precision over a short period of time. The neutron detection efficiencies of the PRT were evaluated using MCNPX code at 2.61x10 -6 , 2.16x10 -6 and 1.14x10 -6 for the respective neutron peak energies of 45, 60 and 75 MeV. The neutron fluences were determined to have been evaluated at an uncertainty of within 6.5% using analysis of measured data and the detection efficiencies. The PRT was also designed so as to be capable of simultaneously obtaining TOF data. The TOF data also increased the reliability of neutron fluence measurements and provided useful information for use in interpreting the source of proton events.

  17. Measurement of neutron and charged particle fluxes toward earthquake prediction

    Science.gov (United States)

    Maksudov, Asatulla U.; Zufarov, Mars A.

    2017-12-01

    In this paper, we describe a possible method for predicting the earthquakes, which is based on simultaneous recording of the intensity of fluxes of neutrons and charged particles by detectors, commonly used in nuclear physics. These low-energy particles originate from radioactive nuclear processes in the Earth's crust. The variations in the particle flux intensity can be the precursor of the earthquake. A description is given of an electronic installation that records the fluxes of charged particles in the radial direction, which are a possible response to the accumulated tectonic stresses in the Earth's crust. The obtained results showed an increase in the intensity of the fluxes for 10 or more hours before the occurrence of the earthquake. The previous version of the installation was able to indicate for the possibility of an earthquake (Maksudov et al. in Instrum Exp Tech 58:130-131, 2015), but did not give information about the direction of the epicenter location. In this regard, the installation was modified by adding eight directional detectors. With the upgraded setup, we have received both the predictive signals, and signals determining the directions of the location of the forthcoming earthquake, starting 2-3 days before its origin.

  18. A study on the optimum fast neutron flux for boron neutron capture therapy of deep-seated tumors.

    Science.gov (United States)

    Rasouli, Fatemeh S; Masoudi, S Farhad

    2015-02-01

    High-energy neutrons, named fast neutrons which have a number of undesirable biological effects on tissue, are a challenging problem in beam designing for Boron Neutron Capture Therapy, BNCT. In spite of this fact, there is not a widely accepted criterion to guide the beam designer to determine the appropriate contribution of fast neutrons in the spectrum. Although a number of researchers have proposed a target value for the ratio of fast neutron flux to epithermal neutron flux, it can be shown that this criterion may not provide the optimum treatment condition. This simulation study deals with the determination of the optimum contribution of fast neutron flux in the beam for BNCT of deep-seated tumors. Since the dose due to these high-energy neutrons damages shallow tissues, delivered dose to skin is considered as a measure for determining the acceptability of the designed beam. To serve this purpose, various beam shaping assemblies that result in different contribution of fast neutron flux are designed. The performances of the neutron beams corresponding to such configurations are assessed in a simulated head phantom. It is shown that the previously used criterion, which suggests a limit value for the contribution of fast neutrons in beam, does not necessarily provide the optimum condition. Accordingly, it is important to specify other complementary limits considering the energy of fast neutrons. By analyzing various neutron spectra, two limits on fast neutron flux are proposed and their validity is investigated. The results show that considering these limits together with the widely accepted IAEA criteria makes it possible to have a more realistic assessment of sufficiency of the designed beam. Satisfying these criteria not only leads to reduction of delivered dose to skin, but also increases the advantage depth in tissue and delivered dose to tumor during the treatment time. The Monte Carlo Code, MCNP-X, is used to perform these simulations. Copyright © 2014

  19. Development of self-powered neutron detectors for neutron flux monitoring in HCLL and HCPB ITER-TBM

    International Nuclear Information System (INIS)

    Angelone, M.; Klix, A.; Pillon, M.; Batistoni, P.; Fischer, U.; Santagata, A.

    2014-01-01

    Highlights: •Self powered neutron detector (SPND) is attractive neutron monitor for TBM in ITER. •In hard neutron spectra (e.g. TBM) there is the need to optimize their response. •Three state-of-the-art SPNDs were tested using fast and 14 MeV neutrons. •The response of SPNDs is much lower than in thermal neutron flux. •FISPACT calculations performed to find out candidate materials in hard spectra. -- Abstract: Self powered neutron detectors (SPND) have a number of interesting properties (e.g. small dimensions, capability to operate in harsh environments, absence of external bias), so they are attractive neutron monitors for TBM in ITER. However, commercially available SPNDs are optimized for operation in a thermal nuclear reactor where the neutron spectrum is much softer than that expected in a TBM. This fact can limit the use of SPND in a TBM since the effective cross sections for the production of beta emitters are much lower in a fast neutron spectrum. This work represents the first attempt to study SPNDs as neutron flux monitors for TBM. Three state-of-the-art SPND available on the market were bought and tested using fast neutrons at TAPIRO fast neutron source of ENEA Casaccia and with 14 MeV neutrons at the Frascati neutron generator (FNG). The results clearly indicate that in fast neutron spectra, the response of SPNDs is much lower than in thermal neutron flux. Activation calculations were performed using the FISPACT code to find out possible material candidates for SPND suitable for operation in TBM neutron spectra

  20. Feasibility study of Self Powered Neutron Detectors in Fast Reactors for detecting local change in neutron flux distribution

    International Nuclear Information System (INIS)

    Jammes, Christian; Filliatre, Philippe; Verma, Vasudha; Hellesen, Carl; Jacobsson Svard, Staffan

    2015-01-01

    Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor system. Diverse possibilities of detector systems installation have to be investigated with respect to practicality and feasibility according to the detection parameters. In this paper, we demonstrate the feasibility of using self powered neutron detectors as in-core detectors in fast reactors for detecting local change in neutron flux distribution. We show that the gamma contribution from fission products decay in the fuel and activation of structural materials is very small compared to the fission gammas. Thus, it is possible for the in-core SPND signal to follow changes in local neutron flux as they are proportional to each other. This implies that the signal from an in-core SPND can provide dynamic information on the neutron flux perturbations occurring inside the reactor core. (authors)

  1. A scintillating fission detector for neutron flux measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stange, Sy [Los Alamos National Laboratory; Esch, Ernst I [Los Alamos National Laboratory; Burgett, Eric A [Los Alamos National Laboratory; May, Iain [Los Alamos National Laboratory; Muenchausen, Ross E [Los Alamos National Laboratory; Taw, Felicia [Los Alamos National Laboratory; Tovesson, Fredrik K [Los Alamos National Laboratory

    2010-01-01

    Neutron flux monitors are commonly used for a variety of nuclear physics applications. A scintillating neutron detector, consisting of a liquid scintillator loaded with fissionable material, has been developed, characterized, and tested in the beam line at the Los Alamos Neutron Science Center, and shows a significant improvement in neutron sensitivity compared with a conventional fission chamber. Recent research on nanocomposite-based scintillators for gamma-ray detection indicates that this approach can be extended to load nanoparticles of fissionable material into a scintillating matrix, with up to three orders of magnitude higher loading than typical fission chambers. This will result in a rugged, cost-efficient detector with high efficiency, a short signal rise time, and the ability to be used in low neutron-flux environments. Initial efforts to utilize the luminescence of uranyl oxide to eliminate the need for wavelength-shifting dyes were unsuccessful. Excitation of uranyl compounds has been reported at wavelengths ranging from 266 nm to 532 nm. However, neither the 300 nm emission of toluene, nor the 350 nm emission of PPO, nor the 410 nm emission of POPOP resulted in significant excitation of and emission by uranyl oxide. As indicated by UV/visible spectroscopy, light emitted at these wavelengths was absorbed by the colored solution. {sup 235}U remains the most attractive candidate for a fissionable scintillator, due to its high fission cross-section and lack of a threshold fission energy, but all solutions containing molecular uranium compounds will be colored, most more highly than the U{sup 6+} compounds used here. Research is therefore continuing toward the fabrication of uranium nanoparticles, in which, due to Rayleigh scattering, the coloration should be less pronounced. The characterization of the thorium-loaded liquid scintillator and the fabrication of the 100 mL detectors for use at LANSCE demonstrated the feasibility of loading fissionable

  2. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium–Beryllium source

    Directory of Open Access Journals (Sweden)

    Abdessamad Didi

    2017-06-01

    Full Text Available Americium–beryllium (Am-Be; n, γ is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci, yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: primarily, it will help us perform neutron activation analysis. Next, it will give us the opportunity to produce radio-elements with short half-lives. Am-Be single and multisource (5 sources experiments were performed within an irradiation facility with a paraffin moderator. The resulting models mainly increase the thermal neutron flux compared to the traditional method with water moderator.

  3. Neutron Spectrum Parameters In Inner Irradiation Channel Of The Nigeria Research Reactor-1 (NIRR-1) For Use In Absolute And KO-NAA Methods

    International Nuclear Information System (INIS)

    Jonah, S.A; Balogun, G.I; Mayaki, M.C.

    2004-01-01

    In Nigeria, the first Nuclear Reactor achieved critically on February 03, 2004 at about 11:35 GMT and has been commissioned or training and research. It is a Miniature Neutron Source Reactor (MNSR), code-named Nigeria Research Reactor-1 (NIRR-1). NIRR-1 has a tan-in-pool structural configuration and a nominal thermal power rating of 30 Kw. With a built-in clean old core excess reactivity of 3.77 mk determined during the on-site zero and critically experimental, the reactor can operate for a n.cm-2 .s-1 in the inner irradiation channels). Under these conditions, the reactor can operate with the same fuel loading for over ten years with a burn-up of <1%. A detailed description of operating characteristics for NIRR-1, measured during the on-site zero-power and criticality experiments has been given elsewhere. In order to extend its utilization to include absolute and ko-NAA methods, the neutron spectrum parameters in the irradiation channels: power and critically experiments has been given elsewhere. In order to extend it's the irradiation channels: thermal-to-epithermal flux ration, F; and epithermal flux shape factor, a in both the inner and outer irradiation channels must be determined experimentally. In this work, we have developed and experimental procedure for monitoring the neutron spectrum parameters in an inner irradiation channel based on irradiation and gamma-ray counting of detector foils via (n,y), (n,p) and (n,a) dosimetry reactions. Results obtained indicate that a thermal neutron flux of (5.14+-0.02) x 1011 n/c m2.s determined by foil activation method in the inner irradiation channel, B2, at a power level of 15.5 kw corresponds to the flux indicators on the control console and the micro-computer control system respectively. Other parameters of the neutron spectrum determined for inner irradiation channel B2, are: a -0.0502+0.003; 18.92+-0.14; F = 3.87=0.23. The method was validated through the comparison of our result with published neutron spectrum

  4. Neutron flux characterization of californium-252 Neutron Research Facility at the University of Texas - Pan American by nuclear analytical technique

    Science.gov (United States)

    Wahid, Kareem; Sanchez, Patrick; Hannan, Mohammad

    2014-03-01

    In the field of nuclear science, neutron flux is an intrinsic property of nuclear reaction facilities that is the basis for experimental irradiation calculations and analysis. In the Rio Grande Valley (Texas), the UTPA Neutron Research Facility (NRF) is currently the only neutron facility available for experimental research purposes. The facility is comprised of a 20-microgram californium-252 neutron source surrounded by a shielding cascade containing different irradiation cavities. Thermal and fast neutron flux values for the UTPA NRF have yet to be fully investigated and may be of particular interest to biomedical studies in low neutron dose applications. Though a variety of techniques exist for the characterization of neutron flux, neutron activation analysis (NAA) of metal and nonmetal foils is a commonly utilized experimental method because of its detection sensitivity and availability. The aim of our current investigation is to employ foil activation in the determination of neutron flux values for the UTPA NSRF for further research purposes. Neutron spectrum unfolding of the acquired experimental data via specialized software and subsequent comparison for consistency with computational models lends confidence to the results.

  5. Measurement and simulation of thermal neutron flux distribution in the RTP core

    Science.gov (United States)

    Rabir, Mohamad Hairie B.; Jalal Bayar, Abi Muttaqin B.; Hamzah, Na’im Syauqi B.; Mustafa, Muhammad Khairul Ariff B.; Karim, Julia Bt. Abdul; Zin, Muhammad Rawi B. Mohamed; Ismail, Yahya B.; Hussain, Mohd Huzair B.; Mat Husin, Mat Zin B.; Dan, Roslan B. Md; Ismail, Ahmad Razali B.; Husain, Nurfazila Bt.; Jalil Khan, Zareen Khan B. Abdul; Yakin, Shaiful Rizaide B. Mohd; Saad, Mohamad Fauzi B.; Masood, Zarina Bt.

    2018-01-01

    The in-core thermal neutron flux distribution was determined using measurement and simulation methods for the Malaysian’s PUSPATI TRIGA Reactor (RTP). In this work, online thermal neutron flux measurement using Self Powered Neutron Detector (SPND) has been performed to verify and validate the computational methods for neutron flux calculation in RTP calculations. The experimental results were used as a validation to the calculations performed with Monte Carlo code MCNP. The detail in-core neutron flux distributions were estimated using MCNP mesh tally method. The neutron flux mapping obtained revealed the heterogeneous configuration of the core. Based on the measurement and simulation, the thermal flux profile peaked at the centre of the core and gradually decreased towards the outer side of the core. The results show a good agreement (relatively) between calculation and measurement where both show the same radial thermal flux profile inside the core: MCNP model over estimation with maximum discrepancy around 20% higher compared to SPND measurement. As our model also predicts well the neutron flux distribution in the core it can be used for the characterization of the full core, that is neutron flux and spectra calculation, dose rate calculations, reaction rate calculations, etc.

  6. Neutron Capture Cross Sections of Zr and La: Probing Neutron Exposure and Neutron Flux in Red Giant Stars

    CERN Multimedia

    Kitis, G; Wiescher, M; Dahlfors, M; Soares, J

    2002-01-01

    We propose to measure the neutron capture cross sections of $^{139}$La, of $^{93}$Zr (t$_{1/2}$)=1.5 10$^{6}$ yr), and of all the stable Zr isotopes at n_TOF. The aim of these measurements is to improve the accuracy of existing results by at least a factor of three in order to meet the quality required for using the s-process nucleosynthesis as a diagnostic tool for neutron exposure and neutron flux during the He burning stages of stellar evolution. Combining these results with a wealth of recent information coming from high-resolution stellar spectroscopy and from the detailed analysis of presolar dust grains will shed new light on the chemical history of the universe. The investigated cross sections are also needed for technological applications, in particular since $^{93}$Zr is one of the major long-lived fission products.

  7. Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

    Science.gov (United States)

    Tiyapun, K.; Chimtin, M.; Munsorn, S.; Somchit, S.

    2015-05-01

    The objective of this work is to demonstrate the method for validating the predication of the calculation methods for neutron flux distribution in the irradiation tubes of TRIGA research reactor (TRR-1/M1) using the MCNP computer code model. The reaction rate using in the experiment includes 27Al(n, α)24Na and 197Au(n, γ)198Au reactions. Aluminium (99.9 wt%) and gold (0.1 wt%) foils and the gold foils covered with cadmium were irradiated in 9 locations in the core referred to as CT, C8, C12, F3, F12, F22, F29, G5, and G33. The experimental results were compared to the calculations performed using MCNP which consisted of the detailed geometrical model of the reactor core. The results from the experimental and calculated normalized reaction rates in the reactor core are in good agreement for both reactions showing that the material and geometrical properties of the reactor core are modelled very well. The results indicated that the difference between the experimental measurements and the calculation of the reactor core using the MCNP geometrical model was below 10%. In conclusion the MCNP computational model which was used to calculate the neutron flux and reaction rate distribution in the reactor core can be used for others reactor core parameters including neutron spectra calculation, dose rate calculation, power peaking factors calculation and optimization of research reactor utilization in the future with the confidence in the accuracy and reliability of the calculation.

  8. Nuclear reactor neutron flux detection by gas optical detectors

    International Nuclear Information System (INIS)

    Dmitriev, A.B.; Il'yashenko, V.S.; Mis'kevich, A.I.; Salamakha, B.S.; Sarylov, V.N.

    1983-01-01

    A gas scintillation detector consisting of a neutron-sensitive volume with 10 B-coated walls connected with a photomultiplier through a hollow-type polished light guide 7m long and 12 mm in dia. is described. The results of measuring its sensitivity, linearity, temperature- and time-dependent stability are given. The detector was tested in the IRT-2000 reactor vertical channel. In the 4X10 7 -10 10 neutr./(cm 2 x s) flux density range the nonlinearity of the measured characteristic does not exceed 5% The detector sensitivity is 4.6x10S -5 pulse/neutr. x cm -2 . Variations in the detector readings during 420 h of reactor operation at nominal power do not exceed +-3.5%, which indicates a high detector stability. The conclusion is drawn that detectors filled with thw He+0.1% N 2 mixture possess the highest sensitivity

  9. The calculation of neutron flux using Monte Carlo method

    Science.gov (United States)

    Günay, Mehtap; Bardakçı, Hilal

    2017-09-01

    In this study, a hybrid reactor system was designed by using 99-95% Li20Sn80 + 1-5% RG-Pu, 99-95% Li20Sn80 + 1-5% RG-PuF4, and 99-95% Li20Sn80 + 1-5% RG-PuO2 fluids, ENDF/B-VII.0 evaluated nuclear data library and 9Cr2WVTa structural material. The fluids were used in the liquid first wall, liquid second wall (blanket) and shield zones of a fusion-fission hybrid reactor system. The neutron flux was calculated according to the mixture components, radial, energy spectrum in the designed hybrid reactor system for the selected fluids, library and structural material. Three-dimensional nucleonic calculations were performed using the most recent version MCNPX-2.7.0 the Monte Carlo code.

  10. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

    International Nuclear Information System (INIS)

    Miller, Marcelo E.; Sztejnberg, Manuel L.; Gonzalez, Sara J.; Thorp, Silvia I.; Longhino, Juan M.; Estryk, Guillermo

    2011-01-01

    Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global

  11. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments.

    Science.gov (United States)

    Miller, Marcelo E; Sztejnberg, Manuel L; González, Sara J; Thorp, Silvia I; Longhino, Juan M; Estryk, Guillermo

    2011-12-01

    A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comisión Nacional de Energía Atómica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Local mixed-field thermal neutron sensitivities and global thermal and mixed

  12. SINUPERM N: a new digital neutron flux density monitoring system

    International Nuclear Information System (INIS)

    Flick, H.A.

    1993-01-01

    The new SINUPERM N System is developed for Neutron Monitoring in nuclear power plants. The development was started in 1989 (with the design specification) and will be finished in 1993 (with the qualification). The first built will be the nuclear power plant in Borselle (Netherlands). The design is based on a microprocessor system with a digital signal processor for calculations and signal filtering. The separation between analogue-input signals and digital processing enables for each detector type special input modules and standard output interfaces e.g. field - bus. The wide range of the Neutron Flux Density from 10 -2 cm -2 s -1 up to 10 8 cm -2 s -1 for the out-of-pile instrumentation and up to 10 14 cm -2 s -1 for the in-core-instrumentation will be covered by the SINUPERM N system. The requirements to be met by the SINUPERM N system are the IEEE 323, IEC 987 and the German standard KTA-3503 for safety systems. Other standards for instrumentation and control systems like IEC 801, IEC 1131 and IEC 68 for EMV, climatic and seismic requirements are also included in the hardware type test. The software requirement depends on the IEC 880 standard. (author). 3 figs

  13. Digital module for neutron flux measurement by Campbell method

    International Nuclear Information System (INIS)

    Baratte, G.

    1987-02-01

    The study reported here concerns a wide range measurement channel for reactor control instrumentation but it may also be useful for specific measurements requiring the Campbell method. A wide range measurement channel allows the processing of the signal issued from a single fission chamber so it's possible to insure control of nuclear reactors in three different running modes: pulse processing, fluctuations and current. The study described in this note includes three parts: - the analogical wide range neutron measurement channel is presented in the first chapter; the fluctuation mode is thoroughly studied; the results of tests and proper limitations of analogical processing are summarized. A theoretical study of the neutron flux measurement by numerical calculation of the fluctuation signal variance is given in the second chapter. The digital module is described in the third chapter; the results of experiments are analysed. The validity of the digital method is proved by means of a practical realisation. The performances obtained with the digital fluctuation test model may be compared with those given by the analogical fluctuation channel which can be used for the control of lower fission rates. The digital module may also be used for any fluctuation measurement where very short response time and broad spectral band of analysis are not strictly necessary [fr

  14. Optimization of neutron flux using fission converter plates for Boron Neutron Capture Therapy study in Tehran reactor

    International Nuclear Information System (INIS)

    Hamidi, S.; Babaei, H.

    2003-01-01

    Boron Neutron Capture Therapy is a binary from of radiation therapy for treatment of deep seated brain tumor, based on the nuclear reaction that occur when boron ( 10 B) is exposed to the thermal neutrons. The stable isotope 10 B is irradiated with low energy or thermal neutrons to yield 4 He nuclei (i.e a particles) and recoiling 7 Li ions. These are absorbed in tumor cells and released their energy in them and destroy tumor cells. This work has tried to optimize neutron flux from Tehran reactor in order to be used in a Boron Neutron Capture Therapy program. Fission converter plates (20% enriched Uranium) have been applied to increase the neutron flux

  15. Neutron spectrum and flux of the cold neutron beam port (C2-3) in JRR-3M

    International Nuclear Information System (INIS)

    Kawabata, Yuji; Ebisawa, Toru; Tasaki, Seiji; Suzuki, Masatoshi; Soyama, Kazuhiko

    2000-03-01

    Neutron beam research in JRR-3M has been promoted and novel experiments using quite very low energy neutrons are proposed in these days. To cope with these new demands, the neutron spectrum and the flux at the end of the cold neutron beam (C2-3) were measured. Both of the time of flight method and the θ -2 θ method were used to measure the spectrum in the very long wavelength range until 4.5 nm. It showed the possibility of the very low energy neutron application. The neutron flux was also measured by the gold foil activation method and it is 2.3x10 8 n/cm 2 /s. These measured results shows the agreements with the results of the commissioning test of JRR-3M about 10 years ago. The aged deterioration of the cold guide tube is not found out. (author)

  16. Measurements of the thermal neutron flux for an accelerator-based photoneutron source.

    Science.gov (United States)

    Taheri, Ali; Pazirandeh, Ali

    2016-12-01

    To have access to an appropriate neutron source is one of the most demanding requirements for neutron studies. This is important specially in laboratory and clinical applications, which need more compact and accessible sources. The most known neutron sources are fission reactors and natural isotopes, but there is an increasing interest for using accelerator based neutron sources because of their advantages. In this paper, we shall present a photo-neutron source prototype which is designed and fabricated to be used for different neutron researches including in-laboratory neutron activation analysis and neutron imaging, and also preliminary studies in boron neutron capture therapy (BNCT). Series of experimental tests were conducted to examine the intensity and quality of the neutron field produced by this source. Monte-Carlo simulations were also utilized to provide more detailed evaluation of the neutron spectrum, and determine the accuracy of the experiments. The experiments demonstrated a thermal neutron flux in the order of 10 7 (n/cm 2 .s), while simulations affirmed this flux and showed a neutron spectrum with a sharp peak at thermal energy region. According to the results, about 60 % of produced neutrons are in the range of thermal to epithermal neutrons.

  17. Particle Filter-Based Recursive Data Fusion With Sensor Indexing for Large Core Neutron Flux Estimation

    Science.gov (United States)

    Tamboli, Prakash Kumar; Duttagupta, Siddhartha P.; Roy, Kallol

    2017-06-01

    We introduce a sequential importance sampling particle filter (PF)-based multisensor multivariate nonlinear estimator for estimating the in-core neutron flux distribution for pressurized heavy water reactor core. Many critical applications such as reactor protection and control rely upon neutron flux information, and thus their reliability is of utmost importance. The point kinetic model based on neutron transport conveniently explains the dynamics of nuclear reactor. The neutron flux in the large core loosely coupled reactor is sensed by multiple sensors measuring point fluxes located at various locations inside the reactor core. The flux values are coupled to each other through diffusion equation. The coupling facilitates redundancy in the information. It is shown that multiple independent data about the localized flux can be fused together to enhance the estimation accuracy to a great extent. We also propose the sensor anomaly handling feature in multisensor PF to maintain the estimation process even when the sensor is faulty or generates data anomaly.

  18. Thermal neutron flux distribution in ET-RR-2 reactor thermal column

    Directory of Open Access Journals (Sweden)

    Imam Mahmoud M.

    2002-01-01

    Full Text Available The thermal column in the ET-RR-2 reactor is intended to promote a thermal neutron field of high intensity and purity to be used for following tasks: (a to provide a thermal neutron flux in the neutron transmutation silicon doping, (b to provide a thermal flux in the neutron activation analysis position, and (c to provide a thermal neutron flux of high intensity to the head of one of the beam tubes leading to the room specified for boron thermal neutron capture therapy. It was, therefore, necessary to determine the thermal neutron flux at above mentioned positions. In the present work, the neutron flux in the ET-RR-2 reactor system was calculated by applying the three dimensional diffusion depletion code TRITON. According to these calculations, the reactor system is composed of the core, surrounding external irradiation grid, beryllium block, thermal column and the water reflector in the reactor tank next to the tank wall. As a result of these calculations, the thermal neutron fluxes within the thermal column and at irradiation positions within the thermal column were obtained. Apart from this, the burn up results for the start up core calculated according to the TRITION code were compared with those given by the reactor designer.

  19. Histological and Physiological Alterations Induced by Thermal Neutron Fluxes in Male Swiss Albino Mice

    International Nuclear Information System (INIS)

    Alzergy, A.A.; Emara, N.M.; Abd El-Latif, A.A.; El-Saady, S.M.M.; Emara, N.M.; Abd El-Latif, A.A.

    2010-01-01

    This work was performed to investigate the biological effects of different thermal neutron fluxes (0.27x10 8 , 0.52X10 8 , 1.089X10 8 , 2.16X10 8 and 4.32X10 8 ) on liver and kidney of male mice using neutron irradiation cell with Ra-Be(α,n) 3 mCi neutron source Leybold (55930). Exposed to various fluxes of thermal neutron induced a dramatic alterations in hepatic and renal functions as indicated by biochemical estimation of several parameters (bilirubin, SGT, and alkaline phosphate .Urea , total protein, and albumin) and confirmed by histological examinations Thermal neutron exposure induces marked increase in the serum activities of total bilirubin, alanine amino transaminase (ALT or GPT), and alkaline phosphate, whereas, urea, total protein and albumin showed marked decline as compared to control group. The physiological changes induced in thermal neutron fluxes dependent manner. Histopathological results revealed mild to severe type of necrosis, and degenerative changes in liver and kidney of male mice exposed to thermal neutron fluxes. Also it was found that the histopathological alterations induced in thermal neutron fluxes dependent manner. It was found that exposed to thermal neutron fluxes irradiation plays prominent role in the development of the physiological alterations in male Swiss albino mice. The Former up normalities as a result of the sequence events followed interaction of radiation with the former biological mater (liver and kidney) of male Swiss albino mice, which are, physical, physicochemical, chemical, and biological stages.

  20. Flux dependence of cluster formation in neutron-irradiated weld material

    International Nuclear Information System (INIS)

    Bergner, F; Ulbricht, A; Hein, H; Kammel, M

    2008-01-01

    The effect of neutron flux on the formation of irradiation-induced clusters in reactor pressure vessel (RPV) steels is an unresolved issue. Small-angle neutron scattering was measured for a neutron-irradiated RPV weld material containing 0.22 wt% impurity Cu. The experiment was focused on the influence of neutron flux on the formation of irradiation-induced clusters at fixed fluence. The aim was to separate and tentatively interpret the effect of flux on the characteristics of the cluster size distribution. We have observed a pronounced effect of neutron flux on cluster size, whereas the total volume fraction of irradiation-induced clusters is insensitive to the level of flux. The result is compatible with a rate theory model according to which the range of applied fluxes covers the transition from a flux-independent regime at lower fluxes to a regime of decelerating cluster growth. The results are confronted with measured irradiation-induced changes of mechanical properties. Despite the observed flux effect on cluster size, both yield stress increase and transition temperature shift turned out to be independent of flux. This is in agreement with the volume fraction of irradiation-induced clusters being insensitive to the level of flux

  1. Absolute measurement of the cross sections of neutron radiative capture for 23Na, Cr, 55Mn, Fe, Ni, 103Rh, Ta, 197Au and 238U in the 10-600keV energy range

    International Nuclear Information System (INIS)

    Le Rigoleur, Claude; Arnaud, Andre; Taste, Jean.

    1976-10-01

    The total energy weighting technique has been applied to measuring absolute neutron capture cross sections for 23 Na, Cr, 55 Mn, Fe, Ni, 103 Rh, Ta, 197 Au, 238 U in the 10-600keV energy range. A non hydrogeneous liquid scintillator was used to detect the gamma from the cascade. The neutron flux was measured with a 10 B INa(Tl) detector or a 6 Li glass scintillator of well known efficiency. The fast time-of-flight technique was used with on line digital computer data processing [fr

  2. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis.

    Science.gov (United States)

    Yuan, H S; Stevens, R C; Bau, R; Mosher, H S; Koetzle, T F

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanal-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH3)3 group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH3)3 groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2(1) (monoclinic), a = 18.564(6) A, b = 7.713(2) A, c = 23.361(8) A, beta = 94.18(4) degrees, V = 3336.0(5) A3, Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis).

  3. Spectral flux of the p-7Li(C Q-M neutron source measured by proton recoil telescope

    Directory of Open Access Journals (Sweden)

    Simakov S.P.

    2010-10-01

    Full Text Available The cyclotron-based fast neutron source at NPI produces mono-energetic neutron fields up to 35 MeV neutron energy using the p + 7Li(carbon backing reactions. To be applied for activation cross-section measurements, not only the intensity of neutron peak, but also the contribution of low-energy continuum in the spectra must be well determined. Simulations of the spectral flux from present source at a position of irradiated samples were performed using CYRIC TOF-data validated in the present work against LA150h by calculations with the transport Monte Carlo code MCNPX. Simulated spectra were tested by absolute measurements using a proton-recoil telescope technique. The recoil-proton spectrometer consisted of a shielded scattering chamber with polyethylene and carbon radiators and the ΔE1-ΔE2-E telescope of silicon-surface detectors located to the neutron beam axis at 45° in the laboratory system. Si-detectors were handled by usual data acquisition system. Dead-time – and pulse-overlap losses of events were determined from the count rate of pulse generator registered during duty cycle of accelerator operation. The proton beam charge and data were taken in the list mode for later replay and analysis. The calculations for 7Li(p,n and 12C(p,n reactions reasonably reproduce CYRIC TOF neutron source spectra. The influence of neutron source set-up (proton beam dimensions, 7Li-foil, carbon stopper, cooling medium, target support/chamber and the geometry-arrangement of irradiated sample on the spectral flux is discussed in details.

  4. Experimental study on the performance of an epithermal neutron flux monitor for BNCT.

    Science.gov (United States)

    Guan, Xingcai; Manabe, Masanobu; Tamaki, Shingo; Liu, Shuangtong; Sato, Fuminobu; Murata, Isao; Wang, Tieshan

    2016-07-01

    The performance of an epithermal neutron (0.5eVflux monitor designed for boron neutron capture therapy (BNCT) was experimentally studied by using a prototype monitor in an appropriate neutron field at the intense deuterium-tritium neutron source facility OKTAVIAN of Osaka University, Japan. It was convinced from the experimental results that the developed monitor worked well and the epithermal neutron fluxes in BNCT neutron sources can be measured within 5% by the monitor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Determination of neutron flux densities in WWR-S reactor core

    International Nuclear Information System (INIS)

    Tomasek, F.

    1989-04-01

    The method is described of determining neutron flux densities and neutron fluences using activation detectors. The basic definitions and relations for determining reaction rates, fluence and neutron flux as well as the characteristics of some reactions and of sitable activation detectors are reported. The flux densities were determined of thermal and fast neutrons and of gamma quanta in the WWR-S reactor core. The data measured in the period 1984-1987 are tabulated. Cross sections for the individual reactions were determined from spectra measurements processed using program SAND-II and cross section library ENDF-B IV. Neutron flux densities were also measured for the WWR-S reactor vertical channels. (E.J.). 10 figs., 8 tabs., 111 refs

  6. TORT/MCNP coupling method for the calculation of neutron flux around a core of BWR

    International Nuclear Information System (INIS)

    Kurosawa, M.

    2005-01-01

    For the analysis of BWR neutronics performance, accurate data are required for neutron flux distribution over the In-Reactor Pressure Vessel equipments taking into account the detailed geometrical arrangement. The TORT code can calculate neutron flux around a core of BWR in a three-dimensional geometry model, but has difficulties in fine geometrical modelling and lacks huge computer resource. On the other hand, the MCNP code enables the calculation of the neutron flux with a detailed geometry model, but requires very long sampling time to give enough number of particles. Therefore, a TORT/MCNP coupling method has been developed to eliminate the two problems mentioned above in each code. In this method, the TORT code calculates angular flux distribution on the core surface and the MCNP code calculates neutron spectrum at the points of interest using the flux distribution. The coupling method will be used as the DOT-DOMINO-MORSE code system. This TORT/MCNP coupling method was applied to calculate the neutron flux at points where induced radioactivity data were measured for 54 Mn and 60 Co and the radioactivity calculations based on the neutron flux obtained from the above method were compared with the measured data. (authors)

  7. TORT/MCNP coupling method for the calculation of neutron flux around a core of BWR.

    Science.gov (United States)

    Kurosawa, Masahiko

    2005-01-01

    For the analysis of BWR neutronics performance, accurate data are required for neutron flux distribution over the In-Reactor Pressure Vessel equipments taking into account the detailed geometrical arrangement. The TORT code can calculate neutron flux around a core of BWR in a three-dimensional geometry model, but has difficulties in fine geometrical modelling and lacks huge computer resource. On the other hand, the MCNP code enables the calculation of the neutron flux with a detailed geometry model, but requires very long sampling time to give enough number of particles. Therefore, a TORT/MCNP coupling method has been developed to eliminate the two problems mentioned above in each code. In this method, the TORT code calculates angular flux distribution on the core surface and the MCNP code calculates neutron spectrum at the points of interest using the flux distribution. The coupling method will be used as the DOT-DOMINO-MORSE code system. This TORT/MCNP coupling method was applied to calculate the neutron flux at points where induced radioactivity data were measured for 54Mn and 60Co and the radioactivity calculations based on the neutron flux obtained from the above method were compared with the measured data.

  8. Measuring planetary neutron albedo fluxes by remote gamma-ray sensing

    Science.gov (United States)

    Haines, E. L.; Metzger, A. E.

    1984-01-01

    In order to measure the planetary neutron albedo fluxes, a neutron-absorbing shield which emits gamma rays of characteristic energy and serves as a neutron detector, is added to a gamma-ray spectrometer (GRS). The gamma rays representing the neutron flux are observed against interference consisting of cosmic gamma rays, planetary continuum and line emission, and gamma rays arising from the interaction of cosmic rays with the GRS and the spacecraft. The uncertainty and minimum detection limits in neutron albedo fluxes are calculated for two missions, a lunar orbiter and a comet nucleus rendezvous. A GRS on a lunar orbiter at 100 km altitude detects a thermal neutron albedo flux as low as 0.002/sq cm/s and an expected flux of about 0.6/sq cm/s is measured with an uncertainty of 0.001/sq cm/s, for a 100 h observation period. For the comet nucleus, again in a 100 h observing period, a thermal neutron albedo flux is detected at a level of 0.006/sq cm/s and an expected flux of about 0.4/sq cm/s is measured with an uncertainty of 0.004/sq cm/s. The expanded geological capabilities made possible by this technique include improvements in H sensitivity, spatial resolution, and measurement depth; and an improved model of induced gamma-ray emission.

  9. International Fusion Material Irradiation Facility (IFMIF) neutron source term simulation and neutronics analyses of the high flux test module

    CERN Document Server

    Simakov, S P; Heinzel, V; Moellendorff, U V

    2002-01-01

    The report describes the new results of the development work performed at Forschungszentrum Karlsruhe on the neutronics of the International Fusion Materials Irradiation Facility (IFMIF). An important step forward has been done in the simulation of neutron production of the deuteron-lithium source using the Li(d,xn) reaction cross sections from evaluated data files. The developed Monte Carlo routine and d-Li reaction data newly evaluated at INPE Obninsk have been verified against available experimental data on the differential neutron yield from deuteron-bombarded thick lithium targets. With the modified neutron source three-dimensional distributions of neutron and photon fluxes, displacement and gas production rates and nuclear heating inside the high flux test module (HFTM) were calculated. In order to estimate the uncertainty resulting from the evaluated data, two independent libraries, recently released by INPE and LANL, have been used in the transport calculations. The proposal to use a reflector around ...

  10. A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

    Science.gov (United States)

    Judge, Darrell L.

    1994-01-01

    A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

  11. Measurement of in-phantom neutron flux and gamma dose in Tehran research reactor boron neutron capture therapy beam line.

    Science.gov (United States)

    Bavarnegin, Elham; Sadremomtaz, Alireza; Khalafi, Hossein; Kasesaz, Yaser

    2016-01-01

    Determination of in-phantom quality factors of Tehran research reactor (TRR) boron neutron capture therapy (BNCT) beam. The doses from thermal neutron reactions with 14N and 10B are calculated by kinetic energy released per unit mass approach, after measuring thermal neutron flux using neutron activation technique. Gamma dose is measured using TLD-700 dosimeter. Different dose components have been measured in a head phantom which has been designed and constructed for BNCT purpose in TRR. Different in-phantom beam quality factors have also been determined. This study demonstrates that the TRR BNCT beam line has potential for treatment of superficial tumors.

  12. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R.E.

    1981-10-12

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed.

  13. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    International Nuclear Information System (INIS)

    Williams, R.E.

    1981-01-01

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed

  14. Analysis of the neutron flux in an annular pulsed reactor by using finite volume method

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Mário A.B. da; Narain, Rajendra; Bezerra, Jair de L., E-mail: mabs500@gmail.com, E-mail: narain@ufpe.br, E-mail: jairbezerra@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Centro de Tecnologia e Geociências. Departamento de Energia Nuclear

    2017-07-01

    Production of very intense neutron sources is important for basic nuclear physics and for material testing and isotope production. Nuclear reactors have been used as sources of intense neutron fluxes, although the achievement of such levels is limited by the inability to remove fission heat. Periodic pulsed reactors provide very intense fluxes by a rotating modulator near a subcritical core. A concept for the production of very intense neutron fluxes that combines features of periodic pulsed reactors and steady state reactors was proposed by Narain (1997). Such a concept is known as Very Intense Continuous High Flux Pulsed Reactor (VICHFPR) and was analyzed by using diffusion equation with moving boundary conditions and Finite Difference Method with Crank-Nicolson formalism. This research aims to analyze the flux distribution in the Very Intense Continuous Flux High Pulsed Reactor (VICHFPR) by using the Finite Volume Method and compares its results with those obtained by the previous computational method. (author)

  15. Neutron spectra at different High Flux Isotope Reactor (HFIR) pressure vessel surveillance locations

    International Nuclear Information System (INIS)

    Remec, I.; Kam, F.B.

    1993-12-01

    This project addresses the potential problem of radiation embrittlement of reactor pressure vessel (RPV) supports. Surveillance specimens irradiated at the High Flux Isotope Reactor (HFIR) at relatively low neutron flux levels (about 1.5E + 8 cm -2 .s -1 ) and low temperatures (about 50 degrees C) showed embrittlement more rapidly than expected. Commercial power reactors have similar flux levels and temperatures at the level vessel support structures. The purposes of this work are to provide the neutron fluence spectra data that are needed to evaluate previously measured mechanical property changes in the HFIR, to explain the discrepancies in neutron flux levels between the nickel dosimeters and two other dosimeters, neptunium and beryllium, and to address any questions or peculiarities of the HFIR reactor environment. The current work consists of neutron and gamma transport calculations, dosimetry measurements, and least-squares logarithmic adjustment to obtain the best estimates for the neutron spectra and the related neutron exposure parameters. The results indicate that the fission rates in neptunium-237 (Np-237) and uranium-238 (U-238) and the helium production rates in beryllium-9 (Be-9) are dominated by photo-induced reactions. The displacements per atom rate for iron (dpa/s) from gamma rays is five times higher than the dpa/s from neutrons. The neutron fluxes in key 7, position 5 do not show any significant gradient in the surveillance capsule, but key 4 and key 2 showed differences in magnitude as well as in the shape of the spectrum. The stainless steel monitor in the V-notch of the Charpy specimens of the surveillance capsules is adequate to determine the neutron flux above 1.0 MeV at the desired V-notch location. Simultaneous adjustment of neutron and gamma fluxes with the measurements has been demonstrated and should avoid future problems with photo-induced reactions

  16. Measurement of angular distribution of neutron flux for the 6MeV race-track microtron based pulsed neutron source.

    Science.gov (United States)

    Patil, B J; Chavan, S T; Pethe, S N; Krishnan, R; Dhole, S D

    2010-09-01

    The 6MeV race track microtron based pulsed neutron source has been designed specifically for the elemental analysis of short lived activation products, where the low neutron flux requirement is desirable. Electrons impinges on a e-gamma target to generate bremsstrahlung radiations, which further produces neutrons by photonuclear reaction in gamma-n target. The optimisation of these targets along with their spectra were estimated using FLUKA code. The measurement of neutron flux was carried out by activation of vanadium at different scattering angles. Angular distribution of neutron flux indicates that the flux decreases with increase in the angle and are in good agreement with the FLUKA simulation.

  17. A development and integration of the concentration database for relative method, k0 method and absolute method in instrumental neutron activation analysis using Microsoft Access

    International Nuclear Information System (INIS)

    Hoh Siew Sin

    2012-01-01

    Instrumental Neutron Activation Analysis (INAA) is offen used to determine and calculate the concentration of an element in the sample by the National University of Malaysia, especially students of Nuclear Science Program. The lack of a database service leads consumers to take longer time to calculate the concentration of an element in the sample. This is because we are more dependent on software that is developed by foreign researchers which are costly. To overcome this problem, a study has been carried out to build an INAA database software. The objective of this study is to build a database software that help the users of INAA in Relative Method and Absolute Method for calculating the element concentration in the sample using Microsoft Excel 2010 and Microsoft Access 2010. The study also integrates k 0 data, k 0 Concent and k 0 -Westcott to execute and complete the system. After the integration, a study was conducted to test the effectiveness of the database software by comparing the concentrations between the experiments and in the database. Triple Bare Monitor Zr-Au and Cr-Mo-Au were used in Abs-INAA as monitor to determine the thermal to epithermal neutron flux ratio (f). Calculations involved in determining the concentration are the net peak area (N p ), the measurement time (t m ), the irradiation time (t irr ), k-factor (k), thermal to epithermal neutron flux ratio (f), the parameters of the neutron flux distribution epithermal (α) and detection efficiency (ε p ). For Com-INAA databases, reference material IAEA-375 Soil was used to calculate the concentration of elements in the sample. CRM, SRM are also used in this database. After the INAA database integration, a verification process was to examine the effectiveness of the Abs-INAA was carried out by comparing the sample concentration between the in database and the experiment. The result of the experimental concentration value of INAA database software performed with high accuracy and precision. ICC

  18. The development of ex-core neutron flux monitoring system for integral reactor

    International Nuclear Information System (INIS)

    Lee, J. K.; Kwon, H. J.; Park, H. Y.; Koo, I. S.

    2004-12-01

    Due to the arrangement of major components within the reactor vessel, the integral reactor has relatively long distance between the core support barrel and the reactor vessel when compared with the currently operating plants. So, a neutron flux leakage at the ex-vessel represents a relatively low flux level which may generate some difficulties in obtaining a wide range of neutron flux information including the source range one. This fact may have an impact upon the design and fabrication of an ex-core neutron flux detector. Therefore, it is required to study neutron flux detectors that are suitable for the installation location and characteristics of an integral reactor. The physical constraints of an integral reactor should be considered when one designs and develops the ex-core neutron flux monitoring detectors and their systems. As a possible installation location of the integral reactor ex-core neutron flux detector assembly, two candidate locations are considered, that is, one is between the core support barrel and the reactor vessel and the other is within the Internal Shielding Tank(IST). And, for these locations, some factors such as the environmental requirements and geometrical restrictions are investigated In the case of considering the inside of the IST as a ex-core neutron flux detector installation position, an electrical insulation problem and a low neutron flux measurement problem arose and when considering the inside of the reactor vessel, a detector's sensitivity variation problem, an electrical insulation problem, a detector's insertion and withdrawal problem, and a high neutron flux measurement problem were encountered. Through a survey of the detector installation of the currently operating plants and detector manufacturer's products, the proposed structure and specifications of an ex-core neutron flux detector are suggested. And, the joint ownership strategy for a proposed detector model is also depicted. At the end, by studying the ex

  19. Measurement with a free neutron beam of absolute neutron-proton forward elastic-scattering differential cross section at intermediate energies

    International Nuclear Information System (INIS)

    Terrien, Y.; Lugol, J.C.; Saudinos, J.

    1987-01-01

    The differential cross section in free n-p forward elastic scattering has been measured for incident neutron energies of 378, 481, 582, 683, 784, 884, and 1085 MeV and for momentum transfer 0.01 2 . The experiment used a recoil-detector ionization chamber which served at the same time as a gas target. Special care has been taken to obtain a precise absolute normalization

  20. Neutron scattering at the high flux isotope reactor at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Yethiraj, M.; Fernandez-Baca, J.A.

    1995-03-01

    Since its beginnings in Oak Ridge and Argonne in the late 1940`s, neutron scattering has been established as the premier tool to study matter in its various states. Since the thermal neutron wavelength is of the same order of magnitude as typical atomic spacings and because they have comparable energies to those of atomic excitations in solids, both structure and dynamics of matter can be studied via neutron scattering. The High Flux Isotope Reactor (HFIR) provides an intense source of neutrons with which to carry out these measurements. This paper summarizes the available neutron scattering facilities at the HFIR.

  1. Upper limit to the 1-20 MeV solar neutron flux.

    Science.gov (United States)

    Lockwood, J. A.; Ifedili, S. O.; Jenkins, R. W.

    1973-01-01

    The upper limit on the quiet time solar neutron flux from 1 to 20 MeV has been measured to be less than .002 neutrons at the 95% confidence level. This result is deduced from the OGO-6 neutron detector measurements of the 'day-night' effect near the equator at low altitudes for the period from June 7 to Dec. 23, 1969. The OGO-6 detector had very low (less than 4%) counting rate contributions from locally produced neutrons in the detecting system and the spacecraft and from charged-particle interactions in the neutron sensor.

  2. Determination of neutron flux with an arbitrary energy distribution by measurement of irradiated foils activity

    International Nuclear Information System (INIS)

    Ljubenov, V.; Milosevic, M.

    2003-01-01

    A procedure for the neutron flux determination in a neutron field with an arbitrary energy spectrum, based on the using of standard methods for the measurement of irradiated foils activity and on the application of the SCALE-4.4a code system for averaged cross section calculation is described in this paper. Proposed procedure allows to include the energy spectrum of neutron flux reestablished in the location of irradiated foils and the resonance self-shielding effects in the foils also. Example application of this procedure is given for the neutron flux determination inside the neutron filter with boron placed in the centre of heavy water critical assembly RB at the Vinca Institute (author)

  3. Design and fabrication of self-powered in-core neutron flux monitor assembly

    International Nuclear Information System (INIS)

    Chung, M.K.; Cho, S.W.; Kang, H.D.; Cho, K.K.; Cho, B.S.; Kang, S.S.

    1980-01-01

    This is the final report on the prototypical fabrication of an in-core neutron flux monitor detector assembly for a specific power reactor conducted by KAERI from July 1, 1978 to December 31, 1979. It is well known that power reactors require a large number of in-core neutron flux detector for reactor regulation and the structures of detector assemblies are different from reactor to reactor. Therefore, from the nature of this project, it should be noted here that the target model of the prototypical farbrication of an in-core neutron flux monitor detector assembly is a VFD-2 System for Wolsung CANDU. It is concluded that fabrication of in-core neutron flux monitor detector assembly for CANDU reactor is technically feasible and will bring economical benefit as much as 50 % of the unit price if they are fabricated in Korea by using partially materials which are available from local market. (author)

  4. On line local measurement of thermal neutron flux on BNCT patient using SPND

    International Nuclear Information System (INIS)

    Miller, M.E.; Sztejnberg Goncalves-Carralves, M.L.; Gonzalez, S.J.

    2006-01-01

    The first on-line neutron flux measurement on a patient using a self-powered neutron detector (SPND) was assessed during the fourth clinical trial of the Boron Neutron Capture Therapy (BNCT) Project carried out at the National Atomic Energy Commission of Argentina (CNEA) and the medical center Angel H. Roffo. The SPND was specially developed and assembled for BNCT by CNEA. Its small size, 1 cm sensible length and 1.9 mm diameter, allowed performing a localized measurement. Since the treated tumors were cutaneous melanomas of nodular type, the SPND was located on the patient's skin. The patient was exposed to three different and consecutive fields and in each of them the SPND was used to measure local thermal neutron fluxes at selected dosimetric reference points. The values of the measured fluxes agreed with the ones estimated by calculation. This trial also demonstrated the usefulness of the SPND for assessing flux on-line. (author)

  5. The Experimental Determination of Thermal Neutron Flux in the Radiochemistry Curriculum

    Science.gov (United States)

    Grant, Patrick M.

    1977-01-01

    Describes an experiment for determining the thermal neutron flux of the light-water nuclear reactor at the University of California, Irvine. The difficulty of the activity can be varied to match the student's level of proficiency. (SL)

  6. Measurement and evaluation of fast neutron flux of CT and OR5 irradiation hole in HANARO

    International Nuclear Information System (INIS)

    Yang, Seong Woo; Choo, Kee Nam; Lee, Seung-Kyu; Kim, Yong Kyun

    2012-01-01

    The irradiation test has been conducted to evaluate the irradiation performance of many materials by a material capsule at HANARO. Since the fast neutron fluence above 1 MeV is important for the irradiation test of material, it must be measured and evaluated exactly at each irradiation hole. Therefore, a fast neutron flux was measured and evaluated by a 09M-02K capsule irradiated in an OR5 irradiation hole and a 10M-01K capsule irradiated in a CT irradiation hole. Fe, Ni, and Ti wires as the fluence monitor were used for the detection of fast neutron flux. Before the irradiation test, the neutron flux and spectrum was calculated for each irradiation hole using an MCNP code. After the irradiation test, the activity of the fluence monitor was measured by an HPGe detector and the reaction rate was calculated. For the OR5 irradiation hole, the radial difference of the fast neutron flux was observed from a calculated data due to the OR5 irradiation hole being located outside the core. Furthermore, a control absorber rod was withdrawn from the core as the increase of the irradiation time at the same irradiation cycle, so the distribution of neutron flux was changed from the beginning to the end of the cycle. These effects were considered to evaluate the fast neutron flux. Neutron spectrums of the CT and OR5 irradiation hole were adjusted by the measured data. The fluxes of a fast neutron above 1 MeV were compared with calculated and measured value. Although the maximum difference was shown at 18.48%, most of the results showed good agreement. (author)

  7. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kronborg-Pettersson, N

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data.

  8. Neutron-flux profile monitor for use in a fission reactor

    Science.gov (United States)

    Kopp, M.K.; Valentine, K.H.

    1981-09-15

    A neutron flux monitor is provided which consists of a plurality of fission counters arranged as spaced-apart point detectors along a delay line. As a fission event occurs in any one of the counters, two delayed current pulses are generated at the output of the delay line. The time separation of the pulses identifies the counter in which the particular fission event occurred. Neutron flux profiles of reactor cores can be more accurately measured as a result.

  9. Abnormal changes in the density of thermal neutron flux in biocenoses near the earth surface.

    Science.gov (United States)

    Plotnikova, N V; Smirnov, A N; Kolesnikov, M V; Semenov, D S; Frolov, V A; Lapshin, V B; Syroeshkin, A V

    2007-04-01

    We revealed an increase in the density of thermal neutron flux in forest biocenoses, which was not associated with astrogeophysical events. The maximum spike of this parameter in the biocenosis reached 10,000 n/(sec x m2). Diurnal pattern of the density of thermal neutron flux depended only on the type of biocenosis. The effects of biomodulation of corpuscular radiation for balneology are discussed.

  10. The AUSTRON-target: the neutron flux of decoupled and poisoned moderators

    International Nuclear Information System (INIS)

    Muhrer, G.; Ninaus, W.; Schachinger, E.

    1995-01-01

    This paper discusses in some detail the time resolution of the thermal neutron flux pulse generated by decoupled, poisoned, ambient temperature water moderators in a flat target configured spallation source. The influence of the reflector material on the time resolution of the neutron pulse is also investigated. (author) 5 figs., 3 refs

  11. Transport calculation of neutron flux distribution in reflector of PW reactor

    International Nuclear Information System (INIS)

    Remec, I.

    1982-01-01

    Two-dimensional transport calculation of the neutron flux and spectrum in the equatorial plain of PW reactor, using computer program DOT 3, is presented. Results show significant differences between neutron fields in which test samples and reactor vessel are exposed. (author)

  12. Studies on the origin of neutron flux fluctuations- Final report; Untersuchungen der Ursachen fuer Neutronenflussschwankungen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Blaesius, Christoph; Herb, Joachim; Kuentzel, Matthias

    2016-01-15

    Aim of the project was to find possible explanations for the neutron flux fluctuations and their changes over the last decades in German PWR. Several models concerning thermal hydraulics, structural mechanics and neutron physics were evaluated. It was shown that up to now no models are available that could explain the observed phenomena. Future studies should focus on interdisciplinary coupling of different models.

  13. STS-36 onboard view of the 'Bonner Sphere', a neutron flux experiment

    Science.gov (United States)

    1990-01-01

    STS-36 experiment called the 'Bonner Sphere', a polyethylene object containing neutron activation foils in its core, is mounted on the middeck starboard wall of Atlantis, Orbiter Vehicle (OV) 104. Different sphere sizes - this one represents the larger ones - sample different portions of high energy neutron flux. The sphere is enclosed in a fire retardant nomex bag.

  14. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, H.S.H.; Stevens, R.C.; Bau, R. (Univ. of Southern California, Los Angeles, CA (United States)); Mosher, H.S. (Stanford Univ., CA (United States)); Koetzle, T.F. (Brookhaven National Lab., Upton, NY (United States))

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanol-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH[sub 3])[sub 3] group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH[sub 3])[sub 3] groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2[sub 1] (monoclinic), a = 18.564(6) [angstrom], b = 7.713(2) [angstrom], c = 23.361(8) [angstrom], [beta] = 94.18(4)[degrees], V = 3336.0(5) [angstrom][sup 3], Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis). 49 refs., 7 figs., 2 tabs.

  15. Neutron-diffraction investigations of flux-lines in superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Forgan, E.M. [Birmingham Univ. (United Kingdom); Lee, S.L. [Saint Andrews Univ. (United Kingdom); McKPaul, D. [Warwick Univ., Coventry (United Kingdom); Mook, H.A. [Oak Ridge National Lab., TN (United States); Cubitt, R. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    SANS has proved an extremely useful tool for investigating flux-line structures within the bulk of superconductors. With high-T{sub c} materials, the scattered intensities are weak, but careful measurements are giving important new information about flux lattices, flux pinning and flux-lattice melting. (author). 10 refs.

  16. Bayesian statistics applied to neutron activation data for reactor flux spectrum analysis

    International Nuclear Information System (INIS)

    Chiesa, Davide; Previtali, Ezio; Sisti, Monica

    2014-01-01

    Highlights: • Bayesian statistics to analyze the neutron flux spectrum from activation data. • Rigorous statistical approach for accurate evaluation of the neutron flux groups. • Cross section and activation data uncertainties included for the problem solution. • Flexible methodology applied to analyze different nuclear reactor flux spectra. • The results are in good agreement with the MCNP simulations of neutron fluxes. - Abstract: In this paper, we present a statistical method, based on Bayesian statistics, to analyze the neutron flux spectrum from the activation data of different isotopes. The experimental data were acquired during a neutron activation experiment performed at the TRIGA Mark II reactor of Pavia University (Italy) in four irradiation positions characterized by different neutron spectra. In order to evaluate the neutron flux spectrum, subdivided in energy groups, a system of linear equations, containing the group effective cross sections and the activation rate data, has to be solved. However, since the system’s coefficients are experimental data affected by uncertainties, a rigorous statistical approach is fundamental for an accurate evaluation of the neutron flux groups. For this purpose, we applied the Bayesian statistical analysis, that allows to include the uncertainties of the coefficients and the a priori information about the neutron flux. A program for the analysis of Bayesian hierarchical models, based on Markov Chain Monte Carlo (MCMC) simulations, was used to define the problem statistical model and solve it. The first analysis involved the determination of the thermal, resonance-intermediate and fast flux components and the dependence of the results on the Prior distribution choice was investigated to confirm the reliability of the Bayesian analysis. After that, the main resonances of the activation cross sections were analyzed to implement multi-group models with finer energy subdivisions that would allow to determine the

  17. Development and application of a detector for absolute measurement of neutron fluence rate in MeV region

    International Nuclear Information System (INIS)

    Silva Dias, M. da.

    1988-01-01

    The development and performance of the DTS (Dual Thin Scintillator) for the absolute measurement of the neutron fluence rate between 1 and 15 MeV is decribed. The DTS detector consists of a pair of organic scintillators in a dual configuration, where the incident produces a proton-recoil which is detected in a 2Π geometry therefore avoiding the effect of the escape of protons. Thin scintillators are used resulting in small multiple scattering corrections. The theoretical caluclations of detector efficiency and proton-recoil spectrum were performed by means of a Monte Carlos code - CARLO DTS. The calculated efficiency was compared to the experimental one at two neutron energies namely 2.446 MeV and 14.04 MeV applying the Time Correlated Associated Particle technique. The theoretical and experimental efficiencies agreed within the experimental uncertainties of 1.44% and 0.77%, respectively. The performance of the DTS has been verified in an absolute 235 U(n,f) cross section measurement between 1 and 6 MeV neutron energy. The cross section results were compared to those obtained replacing the DTS detector by the NBS (National Bureau of Standards, USA) Black Neutron Detector. The agreement was excellent in the overlapping energy interval of the two experiments (between 1 and 3 MeV), within the estimated uncertainly in the range of 1,0 to 1,7%. The agreement with the most recent evaluation from the ENDF/B-VI was excellent in almost all the energy range between 1 and 6 MeV. The 235 U(n,f) cross section, average over the 252 Cf fission neutron spectrum has been evaluated. The result including the cross section values of the present work was 1220 mb, in excellent agreement with the average value among the most recent measurements, 1227 +- 12 mb, and with the value 1213 mb, using the ENDF/B-VI data. (author) [pt

  18. Epithermal neutron flux characterization of the TRIGA Mark III reactor, Salazar, Mexico, for use in Internal Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Herrera Peraza, E.

    1996-01-01

    The non ideality of the epithermal neutron flux distribution at a reactor site parameter (made, using Chloramine-T method. Radiochemical purity and stability of the labelled product were determined by radiochromatography. The labelled Melagenine-II showed two radioactive fractions thermal-to-epithermal neutron ratio (f) were determined in the 3 typical irradiations positions of the TRIGA Mark III reactor of the National Nuclear Research Institute, Salazar, Mexico, using the Cd-ratio for multi monitor and bare bi-isotopic monitor methods respectively. This characterization is of use in the K o - method of neutron activation analysis, recently introduced at the Institute

  19. Measurements of periods, relative abundances and absolute yields of delayed neutrons from fast neutron induced fission of {sup 237}Np

    Energy Technology Data Exchange (ETDEWEB)

    Piksaikine, V. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-03-01

    The experimental method for measurements of the delayed neutron yields and period is presented. The preliminary results of the total yield, relative abundances and periods are shown comparing with the previously reported values. (J.P.N.)

  20. A Method for the neutron flux determination during the activation process

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; Khalil, M.I.

    2000-01-01

    The present work deals with an accurate method for determining the neutron flux coming out from a neutron source during the experimental measurements. Accordingly, a suitable detector, followed by preamplifier and amplifier, is connected to a data acquisition system designed specially for this purpose; and the number of neutrons detected during every sampling period is stored in the PC. The historical file can be used to compute the average or the integral flux during any time period; considering the detector efficiency, geometrical arrangement and the amplification gain

  1. Simulation of the Performance of a Fundamental Neutron Physics Beamline at the High Flux Isotope Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mahurin, R. [University of Tennessee, Knoxville (UTK); Greene, Geoffrey L [ORNL; Koehler, Paul Edward [ORNL; Cianciolo, Vince [ORNL

    2005-05-01

    We study the expected performance of the proposed fundamental neutron physics beamline at the upgraded High Flux Isotope Reactor at Oak Ridge National Laboratory. A curved neutron guide transmits the neutrons from the new cold source into a guide hall. A novel feature of the proposed guide is the use of vertical focusing to increase the flux for experiments that require relatively small cross-section beams. We use the simulation code IB to model straight, multi-channel curved, and tapered guides of various m values. Guide performance for the current NPDGamma and proposed abBA experiments is evaluated.

  2. Mitigation of end flux peaking in CANDU fuel bundles using neutron absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, D.; Chan, P.K., E-mail: dylan.pierce@rmc.ca [Royal Military College of Canada, Kingston ON, (Canada); Shen, W. [Canadian Nuclear Safety Commission, Ottawa ON, (Canada)

    2015-07-01

    End flux peaking (EFP) is a phenomenon where a region of elevated neutron flux occurs between two adjoining fuel bundles. These peaks lead to an increase in fission rate and therefore greater heat generation. It is known that addition of neutron absorbers into fuel bundles can help mitigate EFP, yet implementation in Canada Deuterium Uranium (CANDU) type reactors using natural uranium fuel has not been pursued. Monte Carlo N-Particle code (MCNP) 6.1 was used to simulate the addition of a small amount of neutron absorbers strategically within the fuel pellets. This paper will present some preliminary results collected thus far. (author)

  3. Measuring, Acquiring and recording of the neutron flux intensity at the cairo fourier diffractometer

    CERN Document Server

    Maayouf, R M A; Abdel-Hamid, A S

    2003-01-01

    A simple and low cost, data acquisition system is presented for measuring, acquiring and recording the instant variations of the neutron flux. The system applies especially designed PC acquisition board and software driver to acquire, periodically, the number of digital pulses that arrive from one or more neutron detectors during short sampling time intervals. It has been verified that the data collected from the detectors, using the present system, can be preserved and available for software analysis and statistical operations; such as computing the average and integral neutron flux during any time period.

  4. Modelisation and distribution of neutron flux in radium-beryllium source (226Ra-Be)

    Science.gov (United States)

    Didi, Abdessamad; Dadouch, Ahmed; Jai, Otman

    2017-09-01

    Using the Monte Carlo N-Particle code (MCNP-6), to analyze the thermal, epithermal and fast neutron fluxes, of 3 millicuries of radium-beryllium, for determine the qualitative and quantitative of many materials, using method of neutron activation analysis. Radium-beryllium source of neutron is established to practical work and research in nuclear field. The main objective of this work was to enable us harness the profile flux of radium-beryllium irradiation, this theoretical study permits to discuss the design of the optimal irradiation and performance for increased the facility research and education of nuclear physics.

  5. Measurement of spectra and neutron fluxes on artificial earth satellites from the Cosmos series

    Science.gov (United States)

    Dudkin, V. Y.; Kovalev, Y. Y.; Novikova, M. R.; Potapov, Y. V.; Skvortsov, S. S.; Smirennyy, L. N.

    1975-01-01

    In 1966-1967 measurements were carried out at the altitudes of 200 to 400 km to determine the spectra and fluxes of fast neutrons inside the hermetically sealed artificial earth satellites of the Cosmos series. The detectors used were nuclear emulsions of the B9 and BR types and an emulsion of the P9 type, filled with Li and P. Spectra and fluxes of neutrons in the range of energies from thermal energies to 10 MeV are presented. Neutron doses are also estimated.

  6. Analysis of Neutron Flux Using Monte Carlo Methods

    International Nuclear Information System (INIS)

    Picha, Roppon

    2007-08-01

    Full text: The energy profile of neutrons from a fission reactor core and a neutron irradiation setup are simulated. The neutron doses deposited inside casings of aluminum, cadmium, and tantalum are studied via MCNP simulations to estimate the doses received by materials with different types of shielding. It is found that the difference in dose reduction between cadmium and tantalum is most pronounced at the thermal energy region

  7. Preliminary Design of Neutron Flux and Spectrum Diagnostics in NT-TBM

    Science.gov (United States)

    Yang, Jinwei; Feng, Kaiming; Cheng, Zhi

    2007-04-01

    A special neutron diagnostic system is proposed that facilitates the measurement of neutron fluxes and spectra in the neutronics and tritium production-test blanket module (NT-TBM) without interrupting the operation of the International Thermal-nuclear Experimental Reactor (ITER), for studying the multiplication rate in the neutron multiplier and breeding ratio of tritium in the breeder. This system includes an encapsulated foil activation system, micro-fission chamber detectors (MFC), and a compact neutron spectrometer using a natural diamond detector (NDD). A helium coolant loop with a reasonable diameter is designed carefully for every measurement channel that ensures that the neutron detectors and preamplifiers would work well under a high temperature scenario and that the filling rates of the neutron multiplier (beryllium pebble) and tritium breeder material (Li4SiO4) would not decrease excessively (the expected value>=80%) due to the dimensions of the helium coolant loop.

  8. Measurement of the Absolute Proton and Helium Flux at the Top of the Atmosphere using IMAX

    DEFF Research Database (Denmark)

    Menn, W.; Hof, M.; Reimer, O.

    1996-01-01

    The balloon-borne experiment IMAX launched from Lynn Lake, Canada in 1992 has been used to measure the cosmic ray proton and helium spectra from 0.2 GV to approximately 100 GV. The IMAX apparatus was designed to search for antiprotons and light isotopes using a superconducting magnet spectrometer...... with ancillary scintillators, time-of-flight, and aerogel cherenkov detectors. High resolution drift chambers and MWPCs were used as the tracking devices. Using redundant detectors, an extensive examination of the instrument efficiency was carried out. We present the absolute spectra of protons and helium...

  9. Visualization of neutron flux and power distributions in TRIGA Mark II reactor as an educational tool

    International Nuclear Information System (INIS)

    Snoj, Luka; Ravnik, Matjaz; Lengar, Igor

    2008-01-01

    Modern Monte Carlo computer codes (e.g. MCNP) for neutron transport allow calculation of detailed neutron flux and power distribution in complex geometries with resolution of ∼1 mm. Moreover they enable the calculation of individual particle tracks, scattering and absorption events. With the use of advanced software for 3D visualization (e.g. Amira, Voxler, etc.) one can create and present neutron flux and power distribution in a 'user friendly' way convenient for educational purposes. One can view axial, radial or any other spatial distribution of the neutron flux and power distribution in a nuclear reactor from various perspectives and in various modalities of presentation. By visualizing the distribution of scattering and absorption events and individual particle tracks one can visualize neutron transport parameters (mean free path, diffusion length, macroscopic cross section, up-scattering, thermalization, etc.) from elementary point of view. Most of the people remember better, if they visualize the processes. Therefore the representation of the reactor and neutron transport parameters is a convenient modern educational tool for the (nuclear power plant) operators, nuclear engineers, students and specialists involved in reactor operation and design. The visualization of neutron flux and power distributions in Jozef Stefan Institute TRIGA Mark II research reactor is treated in the paper. The distributions are calculated with MCNP computer code and presented using Amira and Voxler software. The results in the form of figures are presented in the paper together with comments qualitatively explaining the figures. (authors)

  10. Fast neutron flux analyzer with real-time digital pulse shape discrimination

    Science.gov (United States)

    Ivanova, A. A.; Zubarev, P. V.; Ivanenko, S. V.; Khilchenko, A. D.; Kotelnikov, A. I.; Polosatkin, S. V.; Puryga, E. A.; Shvyrev, V. G.; Sulyaev, Yu. S.

    2016-08-01

    Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL-3 and GDT at the Budker Institute (Novosibirsk, Russia) requires sophisticated equipment for neutron-, gamma- diagnostics and upgrading data acquisition systems with online data processing. Measurement of fast neutron flux with stilbene scintillation detectors raised the problem of discrimination of the neutrons (n) from background cosmic particles (muons) and neutron-induced gamma rays (γ). This paper describes a fast neutron flux analyzer with real-time digital pulse-shape discrimination (DPSD) algorithm FPGA-implemented for the GOL-3 and GDT devices. This analyzer was tested and calibrated with the help of 137Cs and 252Cf radiation sources. The Figures of Merit (FOM) calculated for different energy cuts are presented.

  11. Calculation of intermediate neutron flux in the radial reflectors of graphite reactors, comparison with experiments

    International Nuclear Information System (INIS)

    Brisbois, J.; Vergnaud, T.; Oceraies, Y.

    1967-12-01

    In a graphite pile, EDF or Inca type reactor, it is necessary to know the value of the intermediate neutron flux at the output of the lateral reflector in order to determine more precisely the neutron flux at the level of ionisation chambers. A sub critical pile of graphite and natural uranium was built, allowing to reconstitute the geometry of the radiation sources and the disposition of inferior and lateral protections of these piles. This pile is supplied with thermal neutrons coming from the Nereide light water type reactor. Some measurements of intermediate neutron flux have been made in this pile in order to establish a formalism for neutron flux calculation in slowing down in a whole core-lateral reflector, from the distribution of the thermal neutrons flux in the core. The flux calculation is done by age theory in three dimensions, in two homogenous media, separated by an axially semi infinite and laterally finite plane. One of these media includes a distribution of source. The constants are modified in order to take into account the presence of empty channels in the stacking. These calculations are done by the Malaga code. The checking of the formalism has been made in a greater complex geometry of these reactors that introduces an uncertainty factor in the comparison of results. We can however tell that we estimate correctly the variation of the intermediate neutrons flux in the core as well as its descending in a holed lateral reflector. The ratio between the calculation and the experiment is inferior to 2 or 3. Most of the time to a factor 2 [fr

  12. Calculation of the absolute detection efficiency of a moderated 235U neutron detector on the tokamak fusion test reactor

    Science.gov (United States)

    Ku, L. P.; Hendel, H. W.; Liew, S. L.

    1989-08-01

    Neutron transport simulations have been carried out to calculate the absolute detection efficiency of a moderated 235U neutron detector which is used on the TFTR as part of the primary fission detector diagnostic system for measuring fusion power yields. Transport simulations provide a means by which the effects of variations in various shielding and geometrical parameters can be explored. These effects are difficult to study in calibration experiments. The calculational model, benchmarked against measurements, can be used to complement future detector calibrations, when the high level of radioactivity resulting from machine operation may severely restrict access to the tokamak. We present a coupled forward-adjoint algorithm, employing both the deterministic and Monte Carlo sampling methods, to model the neutron transport in the complex tokamak and detector geometries. Sensitivities of the detector response to the major and minor radii, and angular anisotropy of the neutron emission are discussed. A semiempirical model based on matching the calculational results with a small set of experiments produces good agreement (± 15%) for a wide range of source energies and geometries.

  13. Thermal neutron flux measurement using self-powered neutron detector (SPND) at out-core locations of TRIGA PUSPATI Reactor (RTP)

    Science.gov (United States)

    Ali, Nur Syazwani Mohd; Hamzah, Khaidzir; Mohamad Idris, Faridah; Hairie Rabir, Mohamad

    2018-01-01

    The thermal neutron flux measurement has been conducted at the out-core location using self-powered neutron detectors (SPNDs). This work represents the first attempt to study SPNDs as neutron flux sensor for developing the fault detection system (FDS) focusing on neutron flux parameters. The study was conducted to test the reliability of the SPND’s signal by measuring the neutron flux through the interaction between neutrons and emitter materials of the SPNDs. Three SPNDs were used to measure the flux at four different radial locations which located at the fission chamber cylinder, 10cm above graphite reflector, between graphite reflector and tank liner and fuel rack. The measurements were conducted at 750 kW reactor power. The outputs from SPNDs were collected through data acquisition system and were corrected to obtain the actual neutron flux due to delayed responses from SPNDs. The measurements showed that thermal neutron flux between fission chamber location near to the tank liner and fuel rack were between 5.18 × 1011 nv to 8.45 × 109 nv. The average thermal neutron flux showed a good agreement with those from previous studies that has been made using simulation at the same core configuration at the nearest irradiation facilities with detector locations.

  14. The absolute flux of protons and helium at the top of the atmosphere using IMAX

    DEFF Research Database (Denmark)

    Menn, W.; Hof, M.; Reimer, O.

    2000-01-01

    The cosmic-ray proton and helium spectra from 0.2 GeV nucleon(-1) to about 200 GeV nucleon(-1) have been measured with the balloon-borne experiment Isotope Matter-Antimatter Experiment (IMAX) launched from Lynn Lake, Manitoba, Canada, in 1992. IMAX was designed to search for antiprotons and light...... isotopes using a superconducting magnet spectrometer together with scintillators, a time-of-flight system, and Cherenkov detectors. Using redundant detectors, an extensive examination of the instrument efficiency was carried out. We present here the absolute spectra of protons and helium corrected.......15 +/- 1.03) x 10(3)R(-2.79+/-0.08) (m(2) GV s sr)(-1) for helium....

  15. Absolute neutron fluence measurements between 0.5 and 3 MeV and their intercomparisons

    International Nuclear Information System (INIS)

    Wu, M.W.; Guung, T.C.; Pei, C.C.; Yang, T.N.; Hwang, W.S.; Thomas, D.J.

    1999-01-01

    Primary standards of monoenergetic neutron fluences for 0.565, 1.5 and 2.5 MeV neutrons produced by the 7 Li(p,n) 7 Be reaction have been developed for the calibration of neutron dosimeters and spectrometers. The fluences for 0.565 MeV neutrons were measured using both H 2 and CH 4 proton recoil proportional counters with the measured spectra fitted to the modified SPEC-4 Monte Carlo simulations for the subtraction of gamma and recoil carbons. The fluences for 1.5 and 2.5 MeV neutrons were determined with vacuum-type proton recoil telescopes. Various uncertainties for each detector are analyzed and its overall uncertainty is 3.1% for gas counter and less than 3% for the telescope. These neutron fluence standards have been intercompared with those of the National Physical Laboratory of the United Kingdom by the use of two transfer instruments: a long counter and a 3 He detector. The comparison results will be presented and discussed

  16. The Absolute Total Delayed Neutron Yields, Relative Abundances and Half-Lives of Delayed Neutron Groups from Neutron Induced Fission of 232Th, 233U, 236U, 239Pu and 241Am

    International Nuclear Information System (INIS)

    Piksaikin, V.M.; Egorov, A.S.; Mitrofanov, K.V.

    2013-10-01

    The absolute total yield, relative yields and half-lives of individual delayed neutron groups produced from fast neutron-induced fission of 232 Th, 233 U, 236 U, 239 Pu and 241 Am are measured by performing cyclic irradiations of the sample and subsequently measuring the time dependence of the delayed neutron activity decay. The data are analysed using an iterative least-squares fitting procedure to estimate the temporary delayed neutron parameters both for the 6- and 8-group models at each incident neutron energy. The improved data contribute to the continuing effort to meet the data requirements emerging from the current trends in reactor technologies, including the growing interest in fuel recycling strategies and new concepts of actinide burners. (author)

  17. Obtaining absolute spatial flux measurements with a time-resolved pinhole camera

    International Nuclear Information System (INIS)

    Baker, K.L.; Porter, J.L.; Ruggles, L.E.; Fehl, D.L.; Chandler, G.A.; Vargas, M.; Mix, L.P.; Simpson, W.W.; Deeney, C.; Chrien, R.E.; Idzorek, G.C.

    1999-01-01

    A technique is described to determine the spatial x-ray flux emitted from a hohlraum wall and subsequently transmitted through a diagnostic hole. This technique uses x-ray diodes, bolometers, and a time-resolved pinhole camera to determine the spatial flux of x rays emitted through a hohlraum close-quote s diagnostic hole. The primary motivation for this analysis was the relatively long duration, nearly 100 ns, of the x-ray drive present in z-pinch driven hohlraums. This radiation causes plasma to ablate from the hohlraum walls surrounding the diagnostic hole and results in a partial obscuration that reduces the effective area over which diagnostics view the radiation. The effective change in area leads to an underestimation of the wall temperature when nonimaging diagnostics such as x-ray diodes and bolometers are used to determine power and later to infer a wall temperature. An analysis similar to the one described below is then necessary to understand the radiation environment present in x-ray driven hohlraums when these diagnostics are used and hole closure is important. copyright 1999 American Institute of Physics

  18. Validation of neutron flux redistribution factors in JSI TRIGA reactor due to control rod movements

    International Nuclear Information System (INIS)

    Kaiba, Tanja; Žerovnik, Gašper; Jazbec, Anže; Štancar, Žiga; Barbot, Loïc; Fourmentel, Damien; Snoj, Luka

    2015-01-01

    For efficient utilization of research reactors, such as TRIGA Mark II reactor in Ljubljana, it is important to know neutron flux distribution in the reactor as accurately as possible. The focus of this study is on the neutron flux redistributions due to control rod movements. For analyzing neutron flux redistributions, Monte Carlo calculations of fission rate distributions with the JSI TRIGA reactor model at different control rod configurations have been performed. Sensitivity of the detector response due to control rod movement have been studied. Optimal radial and axial positions of the detector have been determined. Measurements of the axial neutron flux distribution using the CEA manufactured fission chambers have been performed. The experiments at different control rod positions were conducted and compared with the MCNP calculations for a fixed detector axial position. In the future, simultaneous on-line measurements with multiple fission chambers will be performed inside the reactor core for a more accurate on-line power monitoring system. - Highlights: • Neutron flux redistribution due to control rod movement in JSI TRIGA has been studied. • Detector response sensitivity to the control rod position has been minimized. • Optimal radial and axial detector positions have been determined

  19. Neutron flux effect on the fracture toughness behavior of Tihange-III RPV material

    International Nuclear Information System (INIS)

    Gerard, R.; Chaouadi, R.; Bertolis, D.

    2015-01-01

    The question whether material test reactor (MTR) data can be used to supplement power reactor pressure vessel (RPV) surveillance data is still debated in the international community and its implications are particularly important in the perspective of long term operation (LTO). However, addressing the flux effect can be confusing if specific material and irradiation variables are not taken into account. This means that the answer to whether there is flux effect or not is neither 'no' nor 'yes' without specifying the application range. Indeed, neutron flux effect was recognized to occur in high Cu-containing steels in the low fluence range. But at high fluence, relevant for long term operation, it becomes difficult to clearly distinguish the differences between high flux and low flux. In this work, we irradiated the low Cu base metal and weld of the Tihange-III surveillance coupon in the BR2 reactor at high flux. The BR2 flux is about two orders of magnitude higher than the flux in the surveillance position. Tensile, Charpy impact and fracture toughness tests were performed on both the surveillance and MTR specimens and compared to assess the neutron flux effect. The results confirm that, at high fluence levels, the flux effect on mechanical properties is not significant, offering therefore the possibility of accelerated irradiation to investigate RPV embrittlement in the high fluence regime relevant for long term operation. (authors)

  20. Flux-Vortex Pinning and Neutron Star Evolution

    Indian Academy of Sciences (India)

    M. Ali Alpar

    2017-09-12

    Sep 12, 2017 ... evolution, outward motion of vortex lines will reduce the dipole magnetic moment in proportion to the rotation rate. The presence of a toroidal array of flux lines makes this mechanism inevitable and independent of the angle between the rotation and magnetic axes. The incompressibility of the flux-line array ...

  1. Observation of magnetic flux line structures in superconductors by small-angle neutron diffraction

    International Nuclear Information System (INIS)

    Forgan, E.M.; Cubitt, R.; Lee, S.L.; Paul, D.McK.; Mook, H.A.; Yethiraj, McK.; Bishop, D.A.; Gammel, P.L.; Kleiman, R.N.

    1993-01-01

    We describe the recent uses of the technique of small-angle neutron diffraction to investigate flux-line structures within the bulk of superconductors in the mixed state. Despite the small signal in superconductors with a long penetration depth, useful results have been obtained in both High-T c and heavy-fermion superconductors. These can give information about the perfection of the flux lattice, the values of characteristics lengths, the influence of crystal anisotropy and defects on the flux lattice structure and orientation, and on temperature and flux lattice melting effects. (orig.)

  2. Calculation of neutron fluxes in biological shield of the TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Bozic, M.; Zagar, T.; Ravnik, M.

    2001-01-01

    The complete calculation of neutron fluxes in biological shield and verification with experimental results is presented. Calculated results are obtained with TORT code (TORT-Three Dimensional Oak Ridge Discrete Ordinates Neutron/Photon Transport Code). Experimental results used for comparison are available from irradiation experiment with selected type of concrete and other materials in irradiation channel 4 in TRIGA Mark II reactor. These experimental results were used as a benchmark. Homogeneous type of problem (without inserted irradiation channel) and problem with asymmetry (inserted beam port 4, filled with different materials) were of interest for neutron flux calculation. Deviation from material data set up as original parameters is also considered (first of all presence of water in concrete and density of concrete) for type of concrete in biological shield and for selected type of concrete in irradiation channel. BUGLE-96 (47 neutron energy groups) library is used. Excellent agreement between calculated and experimental results for reaction rate is received.(author)

  3. Experimental measurements and theoretical simulations for neutron flux in self-serve facility of Dhruva reactor

    International Nuclear Information System (INIS)

    Rana, Y.S.; Mishra, Abhishek; Singh, Tej

    2016-06-01

    Dhruva is a 100 MW th tank type research reactor with natural metallic uranium as fuel and heavy water as coolant, moderator and reflector. The reactor is utilized for production of a large variety of radioisotopes for fulfilling growing demands of various applications in industrial, agricultural and medicinal sectors, and neutron beam research in condensed matter physics. The core consists of two on-power tray rods for radioisotope production and fifteen experimental beam holes for neutron beam research. Recently, a self-serve facility has also been commissioned in one of the through tubes in the reactor for carrying out short term irradiations. To get accurate information about neutron flux spectrum, measurements have been carried out in self-serve facility of Dhruva reactor. The present report describes measurement method, analysis technique and results. Theoretical estimations for neutron flux were also carried out and a comparison between theoretical and experimental results is made. (author)

  4. Calculations of neutron flux spectra induced in the earth's atmosphere by galactic cosmic rays.

    Science.gov (United States)

    Armstrong, T. W.; Chandler, K. C.; Barish, J.

    1973-01-01

    Calculations have been carried out to determine the neutron flux induced in the earth's atmosphere by galactic protons and alpha particles at solar minimum for a geomagnetic latitude of 42 N. Neutron flux spectra in the energy range from about 10 to the minus 8th to about 100,000 MeV at various depths in the atmosphere were calculated by using Monte Carlo and discrete ordinates methods, and various comparisons with experimental data are presented. The magnitude and shape of the calculated neutron leakage spectrum at the particular latitude considered support the theory that the cosmic ray albedo neutron decay (Crand) mechanism is the source of the protons trapped in the inner radiation belt.

  5. Development of network communication function for digitalized neutron flux monitoring instrument

    International Nuclear Information System (INIS)

    Li Kai; Zhang Liangju; Chen Xiaojun; Li Baoxiang

    2002-01-01

    It is essential for a digitalized Neutron Flux Monitoring Instrument to communicate with other parts of Instrumentation and Control System in a network environment, and it is fairly different from the case of traditional analogue nuclear instrumentation. How to satisfy all the requirements of different network structure and communication protocol, which might be adopted in different target nuclear power plant, is a key issue in the design and development of a digitalized neutron flux monitoring instrument. The author describes the overall communication scheme, mainly discusses the design idea and the requirements of the communication interfaces and the implementation of the RS-485 interface as an example of the digitalized neutron flux monitoring instrument, which is under development in the institute

  6. Where Tori Fear to Tread: Hypermassive Neutron Star Remnants and Absolute Event Horizons or Topics in Computational General Relativity

    Science.gov (United States)

    Kaplan, Jeffrey Daniel

    2014-01-01

    Computational general relativity is a field of study which has reached maturity only within the last decade. This thesis details several studies that elucidate phenomena related to the coalescence of compact object binaries. Chapters 2 and 3 recounts work towards developing new analytical tools for visualizing and reasoning about dynamics in strongly curved spacetimes. In both studies, the results employ analogies with the classical theory of electricity and magnetism, first (Ch. 2) in the post-Newtonian approximation to general relativity and then (Ch. 3) in full general relativity though in the absence of matter sources. In Chapter 4, we examine the topological structure of absolute event horizons during binary black hole merger simulations conducted with the SpEC code. Chapter 6 reports on the progress of the SpEC code in simulating the coalescence of neutron star-neutron star binaries, while Chapter 7 tests the effects of various numerical gauge conditions on the robustness of black hole formation from stellar collapse in SpEC. In Chapter 5, we examine the nature of pseudospectral expansions of non-smooth functions motivated by the need to simulate the stellar surface in Chapters 6 and 7. In Chapter 8, we study how thermal effects in the nuclear equation of state effect the equilibria and stability of hypermassive neutron stars. Chapter 9 presents supplements to the work in Chapter 8, including an examination of the stability question raised in Chapter 8 in greater mathematical detail.

  7. The microscopic investigation of structures of moving flux lines by neutron and muon techniques

    International Nuclear Information System (INIS)

    Forgan, E.M.; Charalambous, D.; Kealey, P.G.

    2002-01-01

    We have used a variety of microscopic techniques to reveal the structure and motion of flux line arrangements, when the flux lines in low T c type II superconductors are caused to move by a transport current. Using small-angle neutron scattering by the flux line lattice (FLL), we are able to demonstrate directly the alignment by motion of the nearest-neighbor FLL direction. This tends to be parallel to the direction of flux line motion, as had been suspected from two-dimensional simulations. We also see the destruction of the ordered FLL by plastic flow and the bending of flux lines. Another technique that our collaboration has employed is the direct measurement of flux line motion, using the ultra-high-resolution spectroscopy of the neutron spin-echo technique to observe the energy change of neutrons diffracted by moving flux lines. The muon spin rotation (μSR) technique gives the distribution of values of magnetic field within the FLL. We have recently succeeded in performing μSR measurements while the FLL is moving. Such measurements give complementary information about the local speed and orientation of the FLL motion. We conclude by discussing the possible application of this technique to thin film superconductors. (author)

  8. Energetic ion diagnostics using neutron flux measurements during pellet injection

    Energy Technology Data Exchange (ETDEWEB)

    Heidbrink, W.W.

    1986-01-01

    Neutron measurements during injection of deuterium pellets into deuterium plasmas on the Tokamak Fusion Test Reactor (TFTR) indicate that the fractional increase in neutron emission about 0.5 msec after pellet injection is proportional to the fraction of beam-plasma reactions to total fusion reactions in the unperturbed plasma. These observations suggest three diagnostic applications of neutron measurements during pellet injection: (1) measurement of the beam-plasma reaction rate in deuterium plasmas for use in determining the fusion Q in an equivalent deuterium-tritium plasma, (2) measurement of the radial profile of energetic beam ions by varying the pellet size and velocity, and (3) measurement of the ''temperature'' of ions accelerated during wave heating. 18 refs., 3 figs.

  9. Energetic ion diagnostics using neutron flux measurements during pellet injection

    International Nuclear Information System (INIS)

    Heidbrink, W.W.

    1986-01-01

    Neutron measurements during injection of deuterium pellets into deuterium plasmas on the Tokamak Fusion Test Reactor (TFTR) indicate that the fractional increase in neutron emission about 0.5 msec after pellet injection is proportional to the fraction of beam-plasma reactions to total fusion reactions in the unperturbed plasma. These observations suggest three diagnostic applications of neutron measurements during pellet injection: (1) measurement of the beam-plasma reaction rate in deuterium plasmas for use in determining the fusion Q in an equivalent deuterium-tritium plasma, (2) measurement of the radial profile of energetic beam ions by varying the pellet size and velocity, and (3) measurement of the ''temperature'' of ions accelerated during wave heating. 18 refs., 3 figs

  10. An observer-theoretic approach to estimating neutron flux distribution

    International Nuclear Information System (INIS)

    Park, Young Ho; Cho, Nam Zin

    1989-01-01

    State feedback control provides many advantages such as stabilization and improved transient response. However, when the state feedback control is considered for spatial control of a nuclear reactor, it requires complete knowledge of the distributions of the system state variables. This paper describes a method for estimating the flux spatial distribution using only limited flux measurements. It is based on the Luenberger observer in control theory, extended to the distributed parameter systems such as the space-time reactor dynamics equation. The results of the application of the method to simple reactor models showed that the flux distribution is estimated by the observer very efficiently using information from only a few sensors

  11. Nitrogen determination in wheat by neutron activation analysis using fast neutron flux from a thermal nuclear reactor

    International Nuclear Information System (INIS)

    Ramirez G, T.

    1976-01-01

    This is a study of the technique for the determination of nitrogen and other elements in wheat flour through activation analysis with fast neutrons from a thermal nuclear reactor. The study begins with an introduction about the basis of the analytical methods, the equipment used in activation analysis and a brief description of the neutrons source. In the study are included the experiments carried out in order to determine the flux form in the site of irradiation, the N-13 half life and the interference due to the sample composition. (author)

  12. Calculation of neutron flux distributions in BNCT using removal-diffusion theory

    Energy Technology Data Exchange (ETDEWEB)

    Niemkiewicz, J.; Blue, T.E.; Gupta, N.

    1994-12-31

    Boron neutron capture therapy (BNCT) is under investigation as a treatment modality for brain tumors. Successful routine use of BNCT will require a knowledge of the radiation dose distribution in a patient`s head prior to treatment. This will allow optimization of the treatment to fit the needs of individual patients. Determination of the dose distribution begins with calculation of the neutron flux distribution in the head. Most efforts to date have relied on Monte Carlo or discrete ordinates techniques to calculate this flux distribution. Use of removal-diffusion theory has the advantage of a relatively short computer time to complete a calculation. Previous work by our group has shown good agreement between neutron flux distributions calculated using removal-diffusion theory and Monte Carlo methods for parallel incident neutrons and a rectangular parallelepiped water phantom. This work compares neutron flux distributions calculated using removal-diffusion theory and Monte Carlo methods for a homogeneous ellipsoidal water phantom that models the human head.

  13. Feasibility of laser pumping with neutron fluxes from present-day large tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Jassby, D.L.

    1986-08-01

    The minimum fusion-neutron flux needed to observe nuclear-pumped lasing with tokamaks can be reduced substantially by optimizing neutron scattering into the laser cell, located between adjacent toroidal-field coils. The laser lines most readily pumped are probably the /sup 3/He-Ne lines at 0.633 ..mu.. and in the infrared, where the /sup 3/He-Ne gas is excited by energetic ions produced in the /sup 3/He(n,p)T reaction. These lines are expected to lase at the levels of D-T neutron flux foreseen for the TFTR in 1989 (>>10/sup 12/ n/cm/sup 2//s), while amplification should be observable at the existing levels of D-D neutron flux (greater than or equal to 5 x 10/sup 9/ n/cm/sup 2//s). Lasing on the 1.73 ..mu.. and 2.63 ..mu.. transitions of Xe may be observable at the maximum expected levels of D-T neutron flux in TFTR enhanced by scattering.

  14. Feasibility of laser pumping with neutron fluxes from present-day large tokamaks

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1986-08-01

    The minimum fusion-neutron flux needed to observe nuclear-pumped lasing with tokamaks can be reduced substantially by optimizing neutron scattering into the laser cell, located between adjacent toroidal-field coils. The laser lines most readily pumped are probably the 3 He-Ne lines at 0.633 μ and in the infrared, where the 3 He-Ne gas is excited by energetic ions produced in the 3 He(n,p)T reaction. These lines are expected to lase at the levels of D-T neutron flux foreseen for the TFTR in 1989 (>>10 12 n/cm 2 /s), while amplification should be observable at the existing levels of D-D neutron flux (≥ 5 x 10 9 n/cm 2 /s). Lasing on the 1.73 μ and 2.63 μ transitions of Xe may be observable at the maximum expected levels of D-T neutron flux in TFTR enhanced by scattering

  15. Effect of Different Thermal Neutron Fluxes on Blood of Male Mice

    International Nuclear Information System (INIS)

    Abd El-Latif, A.A.; Saeid, Kh. S.; Abd El-Latif, A.A.; Emara, N.M.; Emara, N.M.

    2010-01-01

    This work deals with the exposing of male mice to different fluxes of thermal neutron .Investigation has been performed by calculating of thermal neutron fluxes(0.27x10 8 N/cm 2 . 1h , 0.54x10 8 N/cm 2 . 1h, 1.08x10 8 N/cm 2 . 1h, 2.16x10 8 N/cm 2 . 3h and 4.32x10 8 N/cm 2 . 6h) which emitted from neutron irradiation cell with source Ra - Be (α,n) have activity 3 m. Ci made by leybold(55930) . The number and differential leucocytes counts types of white blood cells in million per cubic millimeter (W. B. Cs. mm -3 ) ,the number of platelets mm -3 ,the number of red blood cells in million per cubic millimeter (R. B. Cs. mm -3 ), the hemoglobin in Blood (mg/dl), the lymphocytes ,and the eosiniphil leucocytes in blood decrease with increasing thermal neutron fluxes. But neutrophile and monocytes in blood increase with increasing the thermal neutron fluxes

  16. Development of a position-sensitive fission counter and measurement of neutron flux distributions

    International Nuclear Information System (INIS)

    Yamagishi, Hideshi; Soyama, Kazuhiko; Kakuta, Tsunemi

    2001-08-01

    A position-sensitive fission counter (PSFC) that operates in high neutron flux and high gamma-ray background such as at the side of a power reactor vessel has been developed. Neutron detection using the PSFC with a solenoid electrode is based on a delay-line method. The PSFC that has the outer diameter of 25 mm and the sensitive length of 1000 mm was manufactured for investigation of the performances. The PSFC provided output current pulses that were sufficiently higher than the alpha noise, though the PSFC has a solenoid electrode and large electrode-capacitance. The S/N ratio of PSFC outputs proved to be higher than that of ordinary fission counters with 200 mm sensitive length. A performance test to measure neutron flux distributions by a neutron measuring system with the PSFC was carried out by the side of a graphite pile, W2.4 x H1.4 x L1.2 m, with neutron sources, Am-Be 370 GBq x 2. It was confirmed that the neutron flux distribution was well measured with the system. (author)

  17. Fast neutron flux analyzer with real-time digital pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Ivanova, A.A., E-mail: a.a.ivanova@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Zubarev, P.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Ivanenko, S.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Khilchenko, A.D. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Kotelnikov, A.I. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Polosatkin, S.V. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation); Puryga, E.A.; Shvyrev, V.G. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State Technical University, 630092 Novosibirsk (Russian Federation); Sulyaev, Yu.S. [Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2016-08-11

    Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL–3 and GDT at the Budker Institute (Novosibirsk, Russia) requires sophisticated equipment for neutron-, gamma- diagnostics and upgrading data acquisition systems with online data processing. Measurement of fast neutron flux with stilbene scintillation detectors raised the problem of discrimination of the neutrons (n) from background cosmic particles (muons) and neutron-induced gamma rays (γ). This paper describes a fast neutron flux analyzer with real-time digital pulse-shape discrimination (DPSD) algorithm FPGA-implemented for the GOL–3 and GDT devices. This analyzer was tested and calibrated with the help of {sup 137}Cs and {sup 252}Cf radiation sources. The Figures of Merit (FOM) calculated for different energy cuts are presented. - Highlights: • Electronic equipment for measurement of fast neutron flux with stilbene scintillator is presented. • FPGA-implemented digital pulse-shape discrimination algorithm by charge comparison method is shown. • Calibration of analyzer was carried out with {sup 137}Cs and {sup 252}Cf. • Figures of Merit (FOM) values for energy cuts from 1/8 Cs to 2 Cs are from 1.264 to 2.34 respectively.

  18. A neutronic feasibility study for LEU conversion of the High Flux Beam Reactor (HFBR)

    International Nuclear Information System (INIS)

    Pond, R.B.; Hanan, N.A.; Matos, J.E.

    1997-01-01

    A neutronic feasibility study for converting the High Flux Beam Reactor at Brookhaven National Laboratory from HEU to LEU fuel was performed at Argonne National Laboratory. The purpose of this study is to determine what LEU fuel density would be needed to provide fuel lifetime and neutron flux performance similar to the current HEU fuel. The results indicate that it is not possible to convert the HFBR to LEU fuel with the current reactor core configuration. To use LEU fuel, either the core needs to be reconfigured to increase the neutron thermalization or a new LEU reactor design needs to be considered. This paper presents results of reactor calculations for a reference 28-assembly HEU-fuel core configuration and for an alternative 18-assembly LEU-fuel core configuration with increased neutron thermalization. Neutronic studies show that similar in-core and ex-core neutron fluxes, and fuel cycle length can be achieved using high-density LEU fuel with about 6.1 gU/cm 3 in an altered reactor core configuration. However, hydraulic and safety analyses of the altered HFBR core configuration needs to be performed in order to establish the feasibility of this concept. (author)

  19. Digital Real-Time Multiple Channel Multiple Mode Neutron Flux Estimation on FPGA-based Device

    Directory of Open Access Journals (Sweden)

    Thevenin Mathieu

    2016-01-01

    Full Text Available This paper presents a complete custom full-digital instrumentation device that was designed for real-time neutron flux estimation, especially for nuclear reactor in-core measurement using subminiature Fission Chambers (FCs. Entire fully functional small-footprint design (about 1714 LUTs is implemented on FPGA. It enables real-time acquisition and analysis of multiple channels neutron's flux both in counting mode and Campbelling mode. Experimental results obtained from this brand new device are consistent with simulation results and show good agreement within good uncertainty. This device paves the way for new applications perspectives in real-time nuclear reactor monitoring.

  20. A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

    Science.gov (United States)

    Judge, Darrell L.

    1994-01-01

    We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

  1. "Monte Carlo simulation of neutron fluxes on an absolute scale - comparison to experiments"

    Czech Academy of Sciences Publication Activity Database

    Šaroun, Jan; Kulda, Jiří; Wildes, A.; Hiess, A.

    276/278, - (2000), s. 148-149 ISSN 0921-4526 R&D Projects: GA ČR GV202/97/K038; GA AV ČR KSK1048601 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.893, year: 2000

  2. Exotic geophysical phenomena observed in an environmental neutron flux study using EAS PRISMA detectors

    Directory of Open Access Journals (Sweden)

    Alekseenko Victor

    2017-01-01

    Full Text Available Some exotic geophysical events are observed by a global net of electron-neutron detectors (en-detectors developed in the framework of the PRISMA EAS project. Our en-detectors running both on the Earth's surface and underground are continuously measuring the environmental thermal neutron flux. Thermal neutrons are in equilibrium with media and are therefore sensitive to many geophysical phenomena, which are exotic for people studying ultra high-energy cosmic rays or carrying out low background experiments deep underground.

  3. PRORA - program for calculating neutron flux in reactor shielding

    International Nuclear Information System (INIS)

    Sindilaru, G.; Cuculeanu, V.

    1978-06-01

    In order to perform the reactor shielding calculations for the reactor design, it is necessary a fast, accurate method which should take into account the proper shielding geometry. Thus, the PRORA program calculates space-energy neutron distribution in the reactor shielding using age-diffusion approximation and the multigroup formalism. (author)

  4. Neutron flux measurement in the thermal column of the Malaysian TRIGA mark II reactor with MCNP verification

    International Nuclear Information System (INIS)

    Abdel Munem, E.; Shukri, A.; Tajuddin, A.A.

    2006-01-01

    A study of the thermal column of the Malaysian TRIGA Mark II reactor, forming part of a feasibility study for BNCT was proposed in 2001. In the current study, pure metals were used to measure the neutron flux at selected points in the thermal column and the neutron flux determined using SAND-II. Monte Carlo simulation of the thermal column was also carried out. The reactor core was homogenized and calculations of the neutron flux through the graphite stringers performed using MCNP5. The results show good agreement between the measured flux and the MCNP calculated flux. An obvious extension from this is that the MCNP neutron flux output can be utilized as an input spectrum for SAND-II for the flux iteration. (author)

  5. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  6. Neutron flux determinations in the reactors G2 and G3 during operation

    International Nuclear Information System (INIS)

    Boulinier, C.; Faurot, P.; Sagot, M.; Teste du Bailler, A.

    1961-01-01

    After demonstrating the sensitivity of the distribution of power in a production reactor to a deformation caused by dissymmetries of reactivity in the reactor, the authors describe the method of neutron flux determination devised for the reactors G2 and G3 under working conditions; the detector used is a tungsten or nickel wire, the γ activity of which is measured with an ionisation chamber. Several flux determinations are given as examples to illustrate the sensitivity of the method. (author) [fr

  7. Measurement of the energy spectrum of the neutrons inside the neutron flux trap assembled in the center of the reactor core IPEN/MB-01

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto Credidio; Santos, Diogo Feliciano dos; Jerez, Rogerio; Mura, Luis Felipe Liamos, E-mail: ubitelli@ipen.br, E-mail: credidiomura@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    This paper presents the neutron energy spectrum in the central position of a neutron flux trap assembled in the core center of the research nuclear reactor IPEN/MB-01 obtained by an unfolding method. To this end, have been used several different types of activation foils (Au, Sc, Ti, Ni, and plates) which have been irradiated in the central position of the reactor core (setting number 203) at a reactor power level of 64.57 ±2.91 watts . The activation foils were counted by solid-state detector HPGe (gamma spectrometry). The experimental data of nuclear reaction rates (saturated activity per target nucleus) and a neutron spectrum estimated by a reactor physics computer code are the main input data to get the most suitable neutron spectrum in the irradiation position obtained through SANDBP code: a neutron spectra unfolding code that use an iterative adjustment method. The adjustment resulted in 3.85 ± 0.14 10{sup 9} n cm{sup -2} s{sup -1} for the integral neutron flux, 2.41 ± 0.01 10{sup 9} n cm{sup -2} s{sup -1} for the thermal neutron flux, 1.09 ± 0.02 10{sup 9} n cm{sup -2} s{sup -1} for intermediate neutron flux and 3.41± 0.02 10{sup 8} n cm{sup -2} s{sup -1} for the fast neutrons flux. These results can be used to verify and validate the nuclear reactor codes and its associated nuclear data libraries, besides show how much is effective the use of a neutron flux trap in the nuclear reactor core to increase the thermal neutron flux without increase the operation reactor power level. The thermal neutral flux increased 4.04 ± 0.21 times compared with the standard configuration of the reactor core. (author)

  8. Measurement of the energy spectrum of the neutrons inside the neutron flux trap assembled in the center of the reactor core IPEN/MB-01

    International Nuclear Information System (INIS)

    Bitelli, Ulysses d'Utra; Mura, Luiz Ernesto Credidio; Santos, Diogo Feliciano dos; Jerez, Rogerio; Mura, Luis Felipe Liamos

    2013-01-01

    This paper presents the neutron energy spectrum in the central position of a neutron flux trap assembled in the core center of the research nuclear reactor IPEN/MB-01 obtained by an unfolding method. To this end, have been used several different types of activation foils (Au, Sc, Ti, Ni, and plates) which have been irradiated in the central position of the reactor core (setting number 203) at a reactor power level of 64.57 ±2.91 watts . The activation foils were counted by solid-state detector HPGe (gamma spectrometry). The experimental data of nuclear reaction rates (saturated activity per target nucleus) and a neutron spectrum estimated by a reactor physics computer code are the main input data to get the most suitable neutron spectrum in the irradiation position obtained through SANDBP code: a neutron spectra unfolding code that use an iterative adjustment method. The adjustment resulted in 3.85 ± 0.14 10 9 n cm -2 s -1 for the integral neutron flux, 2.41 ± 0.01 10 9 n cm -2 s -1 for the thermal neutron flux, 1.09 ± 0.02 10 9 n cm -2 s -1 for intermediate neutron flux and 3.41± 0.02 10 8 n cm -2 s -1 for the fast neutrons flux. These results can be used to verify and validate the nuclear reactor codes and its associated nuclear data libraries, besides show how much is effective the use of a neutron flux trap in the nuclear reactor core to increase the thermal neutron flux without increase the operation reactor power level. The thermal neutral flux increased 4.04 ± 0.21 times compared with the standard configuration of the reactor core. (author)

  9. Neutron flux mapping inside a cubic and a head PMMA phantom using indirect neutron radiography.

    Science.gov (United States)

    Tsai, Pi-En; Liu, Yuan-Hao; Huang, Chun-Kai; Liu, Hong-Ming; Jiang, Shiang-Huei

    2009-07-01

    This study aims to measure the two-dimensional (2D) neutron spatial distribution inside a cubic and a head PMMA phantom for the purpose of further comparison with the treatment planning. The measurements were made by using the indirect neutron radiography (INR), which utilized a thin copper foil and the imaging plate. The developed image provides satisfactory spatial resolution and very low statistical error (neutron radiography can be a quick and reliable method to provide a 2D neutron spatial distribution inside a phantom.

  10. Solid-state track recorder dosimetry device to measure absolute reaction rates and neutron fluence as a function of time

    Science.gov (United States)

    Gold, Raymond; Roberts, James H.

    1989-01-01

    A solid state track recording type dosimeter is disclosed to measure the time dependence of the absolute fission rates of nuclides or neutron fluence over a period of time. In a primary species an inner recording drum is rotatably contained within an exterior housing drum that defines a series of collimating slit apertures overlying windows defined in the stationary drum through which radiation can enter. Film type solid state track recorders are positioned circumferentially about the surface of the internal recording drum to record such radiation or its secondary products during relative rotation of the two elements. In another species both the recording element and the aperture element assume the configuration of adjacent disks. Based on slit size of apertures and relative rotational velocity of the inner drum, radiation parameters within a test area may be measured as a function of time and spectra deduced therefrom.

  11. Thermal–hydraulic analysis of a candidate design for ITER divertor neutron flux monitor (DNFM)

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Alexandrov, Evgeny; Batyunin, Alexander; Kashchuk, Yuri; Korban, Svetlana; Lyublin, Boris; Obudovsky, Sergey; Senik, Konstantin

    2013-01-01

    The key role in direct measurement of the ITER fusion power is assigned to the neutron diagnostic system for measurement of total neutron flux of the D–D and D–T fusion reaction with the help of a neutron flux monitor located under the divertor dome. High plasma heat loads in this position implies stringent requirements for the detector design and its cooling system to ensure the required temperature operation regime of the neutron detector. The paper describes the neutron flux monitor design developed in close collaboration with IO ITER diagnostic division. Two numerical models (hydraulic and thermal) built up to simulate the water flow in the cooling system and the temperature state of detector components are also presented and discussed. The numerical investigations carried out on the developed models have shown that only good thermal contact between the shell of the detector blocks and water-cooled casing of the monitor (fit, brazing) will provide the required temperature operation regimes of the most temperature-sensitive IFC electrodes. The obtained high temperature of the detector supports makes necessary an auxiliary direct cooling of the supports or their redesign so as to provide their higher thermal conductivity

  12. Neutron point-flux calculation by Monte Carlo

    International Nuclear Information System (INIS)

    Eichhorn, M.

    1986-04-01

    A survey of the usual methods for estimating flux at a point is given. The associated variance-reducing techniques in direct Monte Carlo games are explained. The multigroup Monte Carlo codes MC for critical systems and PUNKT for point source-point detector-systems are represented, and problems in applying the codes to practical tasks are discussed. (author)

  13. A transmission probability method for calculation of neutron flux distributions in hexagonal geometry

    International Nuclear Information System (INIS)

    Wasastjerna, F.; Lux, I.

    1980-03-01

    A transmission probability method implemented in the program TPHEX is described. This program was developed for the calculation of neutron flux distributions in hexagonal light water reactor fuel assemblies. The accuracy appears to be superior to diffusion theory, and the computation time is shorter than that of the collision probability method. (author)

  14. Uncovering flux line correlations in superconductors by reverse monte carlo refinement of neutron scattering data

    DEFF Research Database (Denmark)

    Laver, M.; Forgan, E.M.; Abrahamsen, Asger Bech

    2008-01-01

    We describe the use of reverse Monte Carlo refinement to extract structural information from angle-resolved data of a Bragg peak. Starting with small-angle neutron scattering data, the positional order of an ensemble of flux lines in superconducting Nb is revealed. We discuss the uncovered...

  15. Minimum activation martensitic alloys for surface disposal after exposure to neutron flux

    Science.gov (United States)

    Lechtenberg, Thomas

    1985-01-01

    Steel alloys for long-term exposure to neutron flux have a martensitic microstructure and contain chromium, carbon, tungsten, vanadium and preferably titanium. Activation of the steel is held to within acceptable limits for eventual surface disposal by stringently controlling the impurity levels of Ni, Mo, Cu, N, Co, Nb, Al and Mn.

  16. Computer program calculates gamma ray source strengths of materials exposed to neutron fluxes

    Science.gov (United States)

    Heiser, P. C.; Ricks, L. O.

    1968-01-01

    Computer program contains an input library of nuclear data for 44 elements and their isotopes to determine the induced radioactivity for gamma emitters. Minimum input requires the irradiation history of the element, a four-energy-group neutron flux, specification of an alloy composition by elements, and selection of the output.

  17. Determination of the neutron flux in n_TOF-EAR2 by activation and PPAC measurements

    CERN Document Server

    Villacorta Skarbeli, Aris

    2015-01-01

    This report summarizes the work carried out as summer student. The aim is to measure the neutron flux of the new experiment area of n_TOF with the combination of the results obtained with gold activation and a PPAC detector.

  18. Validation of neutron flux redistribution factors in JSI TRIGA reactor due to control rod movements.

    Science.gov (United States)

    Kaiba, Tanja; Žerovnik, Gašper; Jazbec, Anže; Štancar, Žiga; Barbot, Loïc; Fourmentel, Damien; Snoj, Luka

    2015-10-01

    For efficient utilization of research reactors, such as TRIGA Mark II reactor in Ljubljana, it is important to know neutron flux distribution in the reactor as accurately as possible. The focus of this study is on the neutron flux redistributions due to control rod movements. For analyzing neutron flux redistributions, Monte Carlo calculations of fission rate distributions with the JSI TRIGA reactor model at different control rod configurations have been performed. Sensitivity of the detector response due to control rod movement have been studied. Optimal radial and axial positions of the detector have been determined. Measurements of the axial neutron flux distribution using the CEA manufactured fission chambers have been performed. The experiments at different control rod positions were conducted and compared with the MCNP calculations for a fixed detector axial position. In the future, simultaneous on-line measurements with multiple fission chambers will be performed inside the reactor core for a more accurate on-line power monitoring system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. One procedure for determination of the neutron flux in the nuclear reactor fuel

    International Nuclear Information System (INIS)

    Bulovic, V.; Krtil, J.; Maksimovic, Z.; Martinc, R.

    1979-09-01

    Possibility of determination of the neutron flux in the fuel of a heavy water reactor has been examined. In determination of the flux an iterative procedure was used to compare calculated and measured contents of several fission products. The former contents were determined by calculation of the burning process balance and the latter by non-destructive gamma-spectrometric analysis of fuel. The obtained results prove the possibility of such determination of not only the average value of the flux but also of the change of its intensity during utilization of fuel (author) [sr

  20. Measurement of the fluence flux of monoenergetic neutrons on the Van de Graaff accelerator at Cadarache

    International Nuclear Information System (INIS)

    Szabo, Imre.

    1976-12-01

    This report is a compilation of the different fast neutron flux measurements performed by the Section d'Etudes et de Mesures en Neutrons Rapides (S.E.M.N.R.-CADARACHE) in the energy range extending from 10keV to 14.8 MeV. The facilities used and the methods developed are described. The analysis of the calibrations made during the last few years, led to a final set of values for the efficiency of the ''directional counter''. This counter was used as a reference for microscopic data measurements and also for neutron flux measurements carried out in other laboratories. The accuracy obtained in the 10keV-14MeV range varied from 2 to 3.5% (one standard deviation) [fr

  1. Absolute values of inelastic neutron scattering cross-sections calculated with account taken of the pre-equilibrium mechanism

    International Nuclear Information System (INIS)

    Jahn, H.

    1980-01-01

    Absolute values of secondary energy-dependent inelastic neutron scattering cross sections can be calculated either with the master equation pre-equilibrium formalism of Cline and Blann or with Blann's more recent geometry-dependent hybrid model. The master equation formalism was used at Dubna and Dresden to reproduce experimental results for 14 MeV incident energy. The geometry-dependent hybrid model was used at Karlsruhe to cover for a number of materials the whole range from 5 to 14 MeV incident energy and to reproduce smoothed experimental spectra at 7.45 and 14 MeV. Only the geometry-dependent hybrid model accounts for scattering in the diffuse nuclear surface and thus for a certain average over the direct interaction. It is also free of any fit parameters other than those of the usual optical model. The master equation calculations, on the other hand, are based on nucleon-nucleon scattering cross sections inserted into the high-energy approximation of Kikuchi and Kawai for the intranuclear transition rate. Other approaches require either mass- or energy-dependent or more global fit parameters for a satisfactory reproduction of experimental results, but a genuine prediction of the incident-energy dependence of the inelastic neutron cross section, especially below 14 MeV, is needed for transport and shielding calculations for instance in connection with fusion reactor design studies. (author)

  2. Neutron flux measurement in the central channel (XC-1) of TRIGA 14 MW LEU core

    International Nuclear Information System (INIS)

    BARBOS, D.; BUSUIOC, P.; ROTH, Cs.; PAUNOIU, C.

    2008-01-01

    The TRIGA 14 MW reactor, operated by Institute for Nuclear Research Pitesti, Romania, is a pool type reactor, and has a rectangular shape which holds fuel bundles and is surrounded with beryllium reflectors. Each fuel bundle is composed of 25 nuclear fuel rods. The TRIGA 14 MW reactor was commissioned 28 years ago with HEU fuel rods. The conversion was gradually achieved, starting in February 1992 and completed in March 2006. The full conversion of the 14 MW TRIGA Research Reactor was completed in May 2006 and each step of the conversion was achieved by removal of HEU fuel, replaced by LEU fuel, accompanied by a large set of theoretical evaluation and physical measurements intended to confirm the performances of gradual conversion. After the core full conversion, a program of measurements and comparisons with previous results of core physics and measurements is underway, allowing data acquisition for normal operation, demonstration of safety and economics of the converted core. Neutron flux spectrum measurements in the XC in the XC-1 water 1 water-filled channel were performed using multi multi-foil activation techniques. The neutron spectra and flux are obtained by unfolding from measured reaction rates using SAND II computer code. The integral neutron flux value for LEU core is greater of 13% than for the standard HEU core. Also thermal neutron flux value for converted LEU core is smaller by 0.38% than for the standard HEU core. These differences appear because the foil activation detectors have been irradiated using a pneumatic rabbit having a diameter of 32 mm, whereas foil irradiations in standard HEU core has been performed with a pneumatic rabbit having a diameter of 14 mm, and therefore the neutron spectra in LEU core is less thermalized and the weight of fast neutron is greater

  3. Neutron flux variations near the Earth’s crust. A possible tectonic activity detection

    Directory of Open Access Journals (Sweden)

    B. M. Kuzhevskij

    2003-01-01

    Full Text Available The present work contains some results of observations of neutron flux variations near the Earth’s surface. The Earth’s crust is determined to be a significant source of thermal and slow neutrons, originated from the interaction between the nuclei of the elements of the Earth’s crust and the atmosphere and α-particles, produced by decay of radioactive gases (Radon, Thoron and Actinon. In turn, variations of radioactive gases exhalation is connected with geodynamical processes in the Earth’s crust, including tectonic activity. This determined relation between the processes in the Earth’s crust and neutrons’ flux allow to use variations of thermal and slow neutrons’ flux in order to observe increasing tectonic activity and to develop methods for short-term prediction of natural hazards.

  4. Reactivity And Neutron Flux At Silicide Fuel Element In The Core Of RSG-GAS

    International Nuclear Information System (INIS)

    Hamzah, Amir

    2000-01-01

    In order to 4.8 and 5.2 gr U/cm exp 3 loading of U 3 Si 2 --Al fuel plates characterization, he core reactivity change and neutron flux depression had been done. Control rod calibration method was used to reactivity change measurement and neutron flux distribution was measured using foil activation method. Measurement of insertion of A-type of testing fuel element with U-loading above cannot be done due to technical reason, so the measurement using full type silicide fuel element of 2.96 gr U/cm exp 3 loading. The reactivity change measurement result of insertion in A-9 and C-3 is + 2.67 cent. The flux depression at silicide fuel in A-9 is 1.69 times bigger than oxide and in C-3 is 0.68 times lower than oxide

  5. Use of Germanium as comparator and integral monitor of neutron flux in activation analysis

    International Nuclear Information System (INIS)

    Furnari, Juan C.; Cohen, Isaac M.; Arribere, Maria A.; Kestelman, Abraham J.

    1997-01-01

    The possibility of using germanium as monitor of the thermal and epithermal components of the neutron flux, and comparator in parametric activation analysis, is discussed. The advantages and drawbacks associated to the use of this element are commented on, and the comparison with zirconium, in terms of the determination relative error, is performed. The utilisation of germanium as integral flux monitor, including the fast component of the neutron spectrum, is also discussed. Data corresponding to measurements of k 0 factor for the most relevant gamma transitions from Ge-75 and Be-77 are presented, as well as the results of the reference material analysis, employing germanium as flux monitor and comparator in a simultaneous way. (author). 8 refs., 3 figs., 2 tabs

  6. Reliable estimation of neutron flux in BWR reactor vessel using the tort code (2) application to neutron and gamma flux estimation

    International Nuclear Information System (INIS)

    Kurosawa, M.; Tsukiyama, T.; Hayashi, K.

    2001-01-01

    A neutron and gamma flux distribution around the core of BWR commercial plant in Japan was calculated, using a three-dimensional transport code, TORT in DOORS32 code system. In the external of the core, the bottom of the model was at an elevation of 150 cm below the bottom of active fuel, the top of the model was at an elevation of the top of the shroud head dome and the radial part of the model was to the outside of the reactor pressure vessel. The top guide beams were modeled explicitly to obtain the neutron and gamma flux distribution both in the beams and outside beams. The each control rod guide tube was also modeled with homogeneous region which included the blade wing and poison tubes so that we could obtain the neutron and gamma flux distribution around the each control rod guide tube. The calculation model mentioned above needed very large memory size which exceeded a few decade giga-bytes. As the using the splicing/coupling method had uncertainly at the splicing/coupling boundary, in this work the calculation was performed without this splicing/coupling method. On the other hand, radioactivity data were measured for a few pieces of the top guide beam, shroud and in-core monitor guide tube in the same plant which was analyzed in the above calculation. So the calculation results were able to be compared with those measured data as benchmarking and at the end of this task, the C/M values at these measured points were obtained and calculation model using TORT was evaluated. (authors)

  7. Photoneutron Flux Measurement via Neutron Activation Analysis in a Radiotherapy Bunker with an 18 MV Linear Accelerator

    Directory of Open Access Journals (Sweden)

    Çeçen Yiğit

    2017-01-01

    Full Text Available In cancer treatment, high energy X-rays are used which are produced by linear accelerators (LINACs. If the energy of these beams is over 8 MeV, photonuclear reactions occur between the bremsstrahlung photons and the metallic parts of the LINAC. As a result of these interactions, neutrons are also produced as secondary radiation products (γ,n which are called photoneutrons. The study aims to map the photoneutron flux distribution within the LINAC bunker via neutron activation analysis (NAA using indium-cadmium foils. Irradiations made at different gantry angles (0°, 90°, 180° and 270° with a total of 91 positions in the Philips SLI-25 linear accelerator treatment room and location-based distribution of thermal neutron flux was obtained. Gamma spectrum analysis was carried out with high purity germanium (HPGe detector. Results of the analysis showed that the maximum neutron flux in the room occurred at just above of the LINAC head (1.2x105 neutrons/cm2.s which is compatible with an americium-beryllium (Am-Be neutron source. There was a 90% decrease of flux at the walls and at the start of the maze with respect to the maximum neutron flux. And, just in front of the LINAC door, inside the room, neutron flux was measured less than 1% of the maximum.

  8. Apparatus for nuclear transmutation and power production using an intense accelerator-generated thermal neutron flux

    Science.gov (United States)

    Bowman, Charles D.

    1992-01-01

    Apparatus for nuclear transmutation and power production using an intense accelerator-generated thermal neutron flux. High thermal neutron fluxes generated from the action of a high power proton accelerator on a spallation target allows the efficient burn-up of higher actinide nuclear waste by a two-step process. Additionally, rapid burn-up of fission product waste for nuclides having small thermal neutron cross sections, and the practicality of small material inventories while achieving significant throughput derive from employment of such high fluxes. Several nuclear technology problems are addressed including 1. nuclear energy production without a waste stream requiring storage on a geological timescale, 2. the burn-up of defense and commercial nuclear waste, and 3. the production of defense nuclear material. The apparatus includes an accelerator, a target for neutron production surrounded by a blanket region for transmutation, a turbine for electric power production, and a chemical processing facility. In all applications, the accelerator power may be generated internally from fission and the waste produced thereby is transmuted internally so that waste management might not be required beyond the human lifespan.

  9. Measure of thermal neutron flux in the IPEN/MB-01 reactor using 197 Au wire activation detectors

    International Nuclear Information System (INIS)

    Marques, Andre Luis Ferreira

    1995-01-01

    This dissertation has aimed at developing a neutron flux measurement technique by means of detectors activation analysis. The main task of this work was the implementation of this thermal neutron flux measurement technique, using gold wires as activation detectors in the IPEN/MB-01 reactor core. The neutron thermal flux spatial distribution was obtained by gold wire activation technique, with wire diameters of 0.125 mm and 0.250 mm in seven selected reactor experimental channels. The values of thermal flux were about 10 9 neutrons/cm 2 .s. This experiment has been the first one conducted with gold wires in the IPEN/MB-01 reactor, being this technique implemented for use by experiments in flux mapping of the core

  10. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  11. Neutron flux measurement in the central channel (XC1) of TRIGA 14 MW LEU core

    International Nuclear Information System (INIS)

    Barbos, D.; Busuioc, P.; Paunoiu, C.; Roth, Cs.

    2008-01-01

    The full conversion of the 14 MW TRIGA Research Reactor was completed in May 2006 and each step of the conversion was achieved by removal of HEU fuel and replaced by LEU fuel. The operation was accompanied by a large set of theoretical evaluations and physical measurements intended to confirm the performances of gradual conversion. After the core full conversion, a program of measurements and comparisons with previous results of core physics and measurements is underway, allowing data acquisition for normal operation, demonstration of safety and economics of the converted core. Neutron flux spectrum measurements in the XC-1 water-filled channel were performed using multi-foil activation techniques. The neutron spectra and flux are obtained by unfolding from measured reaction rates using SAND II computer code. The integral flux measured value for LEU core and 14 MW reactor power is 4.66x10 14 n/cm 2 s. For standard core the integral neutron flux for 14 MW reactor power was 4.27x10 14 n/cm 2 s. (authors)

  12. Neutron Scattering Facilities at the Oak Ridge National Laboratory High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Selby, D. L.

    2013-01-01

    This paper will address four aspects of the neutron scattering science utilization of the High Flux Isotope Reactor (HFIR): 1) Since the last IGORR meeting, two instruments (IMAGINE- a single crystal diffractometer and a polarized beam station) have been declared operational. In addition, cold neutron beam line CG-1D has been fully devoted to imaging studies. One specific characteristic that will be discussed will be the neutron optics mirror system that has been used for the IMAGINE instrument in lieu of a conventional neutron guide. 2) For the last 15 years there has been a focused effort to fully utilize the open neutron beam positions at the High Flux Isotope Reactor (HFIR). With the addition of the new instruments and plans to build a new spin echo test station at beam port CG-4B we will have filled out all 16 presently available beam instrument positions. Therefore, at HFIR we are starting to shift our focus to major upgrades of existing instruments. Many of these instruments are now over 10 years old and new technology, including advances in neutron optics techniques, can provide significant increases in the utilization of the existing neutron beams. In addition, upgrades will allow the use of new sample environment equipment that is presently prohibited because of geometry restrictions. The plans for these upgrades and expected gains in performance will be discussed. 3) Another proposal to increase the utilization capabilities at HFIR is to build a new building next to the HB-4 cold neutron guide hall that would provide space for 9 lab facilities. These labs would include magnet, sample environment, polarization, and sample preparation support capabilities for the neutron scattering instruments. In addition, there is still a proposal being discussed with the United States Department of Energy to build a second moderator and guide hall tied to the HB-2 beam line at HFIR. The status of these two proposed major projects will be addressed. 4) Finally, the

  13. Flux effect on neutron irradiation embrittlement of reactor pressure vessel steels irradiated to high fluences

    International Nuclear Information System (INIS)

    Soneda, N.; Dohi, K.; Nishida, K.; Nomoto, A.; Iwasaki, M.; Tsuno, S.; Akiyama, T.; Watanabe, S.; Ohta, T.

    2011-01-01

    Neutron irradiation embrittlement of reactor pressure vessel (RPV) steels is of great concern for the long term operation of light water reactors. In particular, the embrittlement of the RPV steels of pressurized water reactors (PWRs) at very high fluences beyond 6*10 19 n/cm 2 , E > 1 MeV, needs to be understood in more depth because materials irradiated in material test reactors (MTRs) to such high fluences show larger shifts than predicted by current embrittlement correlation equations available worldwide. The primary difference between the irradiation conditions of MTRs and surveillance capsules is the neutron flux. The neutron flux of MTR is typically more than one order of magnitude higher than that of surveillance capsule, but it is not necessarily clear if this difference in neutron flux causes difference in mechanical properties of RPV. In this paper, we perform direct comparison, in terms of mechanical property and microstructure, between the materials irradiated in surveillance capsules and MTRs to clarify the effect of flux at very high fluences and fluxes. We irradiate the archive materials of some of the commercial reactors in Japan in the MTR, LVR-15, of NRI Rez, Czech Republic. Charpy impact test results of the MTR-irradiated materials are compared with the data from surveillance tests. The comparison of the results of microstructural analyses by means of atom probe tomography is also described to demonstrate the similarity / differences in surveillance and MTR-irradiated materials in terms of solute atom behavior. It appears that high Cu material irradiated in a MTR presents larger shifts than those of surveillance data, while low Cu materials present similar embrittlement. The microstructural changes caused by MTR irradiation and surveillance irradiation are clearly different

  14. Measurement of Neutron and Muon Fluxes 100~m Underground with the SciBath Detector

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, Lance [Indiana Univ., Bloomington, IN (United States)

    2014-01-01

    The SciBath detector is an 80 liter liquid scintillator detector read out by a three dimensional grid of 768 wavelength-shifting fibers. Initially conceived as a fine-grained charged particle detector for neutrino studies that could image charged particle tracks in all directions, it is also sensitive to fast neutrons (15-200 MeV). In fall of 2011 the apparatus performed a three month run to measure cosmic-induced muons and neutrons 100~meters underground in the FNAL MINOS near-detector area. Data from this run has been analyzed and resulted in measurements of the cosmic muon flux as \

  15. Measurement of moderated neutron fluxes using Au-La-Co-Mn sandwich detectors

    International Nuclear Information System (INIS)

    Costa, L.

    1967-03-01

    In order to measure the energy spectra of moderated neutrons in reactors or in their protections, it is possible to improve resonating detectors by using three of them together: the difference between the activities of the exterior detectors and that of the central detector is proportional to the neutron flux at the resonance energy. The sensitivity obtained is lower but the energy selectivity is better than with simple detectors. The object of this work has been to develop this technique for four substances: gold, lanthanum, cobalt and manganese which have resonance energies at 4.9 - 73.5 - 132 and 337 eV. (author) [fr

  16. Calculation of self-shielding coefficients, flux depression and cadmium factor for thermal neutron flux measurement of the IPEN/MB-01 reactor

    International Nuclear Information System (INIS)

    Marques, Andre Luis Ferreira; Ting, Daniel Kao Sun; Mendonca, Arlindo Gilson

    1996-01-01

    A calculation methodology of Flux Depression, Self-Shielding and Cadmium Factors is presented, using the ANISN code, for experiments conducted at the IPEN/MB-01 Research Reactor. The correction factors were determined considering thermal neutron flux and 0.125 e 0.250 mm diameter of 197 Au wires. (author)

  17. Accelerator-driven sub-critical research facility with low-enriched fuel in lead matrix: Neutron flux calculation

    Directory of Open Access Journals (Sweden)

    Avramović Ivana

    2007-01-01

    Full Text Available The H5B is a concept of an accelerator-driven sub-critical research facility (ADSRF being developed over the last couple of years at the Vinča Institute of Nuclear Sciences, Belgrade, Serbia. Using well-known computer codes, the MCNPX and MCNP, this paper deals with the results of a tar get study and neutron flux calculations in the sub-critical core. The neutron source is generated by an interaction of a proton or deuteron beam with the target placed inside the sub-critical core. The results of the total neutron flux density escaping the target and calculations of neutron yields for different target materials are also given here. Neutrons escaping the target volume with the group spectra (first step are used to specify a neutron source for further numerical simulations of the neutron flux density in the sub-critical core (second step. The results of the calculations of the neutron effective multiplication factor keff and neutron generation time L for the ADSRF model have also been presented. Neutron spectra calculations for an ADSRF with an uranium tar get (highest values of the neutron yield for the selected sub-critical core cells for both beams have also been presented in this paper.

  18. High-sensitive spectrometer of fast neutrons and the results of fast neutron background flux measurements at the Gallium-Germanium Solar Neutrino Experiment

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S

    2002-01-01

    The principle of operation, design, registration system and main characteristics of a fast neutron spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to neutron fluxes of 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 and lower. The detection efficiency of fast neutrons with simultaneous energy measurement was determined from Monte-Carlo simulation to be equal to 0.11+-0.01. The background counting rate in the detector corresponds to a neutron flux of (6.5+-2.1)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The natural neutron flux from the surrounding mine rock at the depth of 4600 m of water equivalent was measured to be (7.3+-2.4)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The flux of fast neutrons in the SAGE main room was measured to be <2.3x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in 1.0-11.0 MeV energy range.

  19. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  20. Calculated neutron dose rates and flux densities from implantable californium-252 point and line sources.

    Science.gov (United States)

    Shapiro, A; Schwartz, B; Windham, J P; Kereiakes, J G

    1976-01-01

    The results of neutron-transport flux-density and dose rate calculations for implantable Californium-252 point and line sources in essentially infinite tissue-equivalent material are presented. The point-source flux densities were obtained from a discrete ordinates calculation, and the point dose rates were established by multiplying the flux densities by their appropriate kerma factors. Line-source dose rates were evaluated by integrating the point dose rates over the length of the line source. Dose-rate data are given within a 20 X 20-cm region from the source center for source lengths of 1.5, 2, and 3 cm. The dose rates established by these calculations showed good agreement with an independent Monte Carlo calculation. Detailed point-source flux-density data as a function of energy and position are also given.

  1. Production of a pulseable fission-like neutron flux using a monoenergetic 14 MeV neutron generator and a depleted uranium reflector

    Science.gov (United States)

    Koltick, D.; McConchie, S.; Sword, E.

    2008-04-01

    The design and performance of a pulseable neutron source utilizing a D-T neutron generator and a depleted uranium reflector are presented. Approximately half the generator's 14 MeV neutron flux is used to produce a fission-like neutron spectrum similar to 252Cf. For every 14 MeV neutron entering the reflector, more than one fission-like neutron is reflected back across the surface of the reflector. Because delayed neutron production is more than two orders of magnitude below the prompt neutron production, the source takes full advantage of the generator's pulsed mode capability. Applications include all elemental characterization systems using neutron-induced gamma-ray spectroscopy. The source simultaneously emits 14 MeV neutrons optimal to excite fast neutron-induced gamma-ray signals, such as from carbon and oxygen, and fission-like neutrons optimal to induce neutron capture gamma-ray signals, such as from hydrogen, nitrogen, and chlorine. Experiments were performed, which compare well to Monte Carlo simulations, showing that the uranium reflector enhances capture signals by up to a factor of 15 compared to the absence of a reflector.

  2. Neutron flux of 100kW in the irradiation terminals of the IPR-R1 Triga Reactor

    International Nuclear Information System (INIS)

    Zangirolami, Dante Marco

    2009-01-01

    In this work, it was carried out a study of the neutron flux in the IPR-R1 TRIGA reactor irradiation facilities: rotary specimen rack (RSR), pneumatic transfer tube two (PTT2) and the central thimble (CT). The objective was to obtain the neutron flux profile on the RSR, which has forty irradiation positions, and also values for the thermal and epithermal neutron fluxes of some RSR positions and also of the PTT2 and of the CT facility. It was applied the neutron activation analysis of a reference material, Al-Au (0.1%) alloy. Irradiations were performed on 16 different dates. It was concluded that for the RSR, the average value of thermal and epithermal neutron fluxes depends on the vertical position of the reactor control rods. Neutron flux variations along the RSR form a characteristic profile, whose values depend on the location of the irradiation position in the reactor core and on the control rods vertical position. In the RSR, the obtained values of thermal and epithermal neutron flux were (8.1 +- 0.3) x 10 11 n.cm -2 .s -1 , and (3.4 +- 0.2)x10 10 n.cm -2 .s -1 , respectively. For the PTT2 and the CT, the values for the epithermal neutron flux were respectively (3.3 +- 0.2) x 10 9 n.cm -2 .s -1 and (2.6 +- 0.1) x 10 11 n.cm -2 .s -1 . For these facilities, the thermal neutron flux was estimated, and the obtained values were (2.4 +- 0.2) x 10 11 n.cm -2 .s -1 and (2.8 +- 0.1)x10 12 n.cm -2 .s -1 for the PTT2 and the CT, respectively. (author)

  3. Lunar neutron leakage fluxes as a function of composition and hydrogen content

    Science.gov (United States)

    Feldman, W. C.; Reedy, R. C.; Mckay, D. S.

    1991-01-01

    Areas of the moon that might have enhanced concentrations of hydrogen are discussed. The fluxes of thermal, epithermal, and fast neutrons escaping from the lunar surface were calculated for eight different compositions and several hydrogen contents. These flux ratios depend on composition and are very sensitive to the hydrogen content. Their measurement using flight-proven techniques from lunar orbit should allow detection and identification of hydrogen residing in either permanently shaded cold traps near the lunar poles or mature regoliths. Knowledge of composition, especially of Fe and Ti, improves the thresholds for hydrogen detection and also could allow identification of Gd and Sm.

  4. Measurement of the epithermal neutron flux of the Argonauta reactor by the Sandwich method

    International Nuclear Information System (INIS)

    Nascimento, H.M.

    1973-01-01

    A common method of obtaining information about the neutron spectrum in the energy range of 1 eV to a few keV is by using resonance sandwich detectors. A sandwich detector is usually made up of three foils placed one on top of the other, each having the same thickness and being made of the same material which has a pronounced absorption resonance. To make an adequate evaluation, the sandwich method was compared with one using an isolated detector. The results obtained from approximate theoretical calculations were checked experimentally, using In, Au and Mn foils, in an isotropic 1/E flux in the Argonaut Reactor at I.E.N. As practical application of this method, the deviation from a 1/E spectrum of the epithermal neutron flux in the core and external graphite reflector of the Argonaut Reactor has been measured with the sandwich foils previously calibrated in a 1/E spectrum. (author)

  5. Theoretical and experimental study of collectrons for epithermal neutron flux in reactors

    International Nuclear Information System (INIS)

    Agu, M.N.

    1986-01-01

    A theoretical study of nuclear reactions and electric charge displacements arising in sensitivity to thermal and epithermal neutrons in collectrons allowed a computer code conception. Collectrons in Rhodium, Silver, Cobalt, Hafnium, Erbium, Gadolinium and Holmium have been tested in different radiation fields given by neutron or gamma filters irradiated in different places of Melusine and Siloe reactors. Some emitters were covered with different steel, nickel or zircaloy thicknesses. Theoretical and experimental results are consistent; that validate the computer code and show possibilities and necessity of covering collectron emitters to reduce or cancel the gamma sensitivity and to improve response instantaneity. A selective measurement of epithermal neutron flux can by this way, made by associating two types of collectrons [fr

  6. Design of an automatic sample changer for the measurement of neutron flux by gamma spectrometry

    International Nuclear Information System (INIS)

    Gago, Javier; Bruna, Ruben; Baltuano, Oscar; Montoya, Eduardo; Descreaux, Killian

    2014-01-01

    This paper presents calculus, selection and components design for the construction of an automatic system in order to measure neutron flux in a working nuclear reactor by the gamma spectrometry technique using samples irradiated on the RP-10 nucleus. This system will perform the measurement of interchanging 100 samples in a programed and automatic way, reducing operation time by the user and obtaining more accurate measures. (authors).

  7. TMI-2 source and intermediate range neutron flux monitors data report

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-03-01

    This is a report on the preparation of data from the TMI-2 excore source and intermediate range neutron flux monitors for inclusion into the TMI Data Base. The sources of the as-recorded data are discussed as well as the process of transforming these data into digital form. The corrections to the as-recorded data are given and the data quality classification and uncertainty are established. The identifiers attached to each data set in the TMI Data Base are given

  8. Neutron flux and annealing effects on irradiation hardening of RPV materials

    Science.gov (United States)

    Chaouadi, R.; Gérard, R.

    2011-11-01

    This paper aims to examine an eventual effect of neutron flux, sometimes referred to as dose rate effect, on irradiation hardening of a typical A533B reactor pressure vessel steel. Tensile tests on both low flux (reactor surveillance data) and high flux (BR2 reactor) were performed in a large fluence range. The obtained results indicate two features. First, the surveillance data exhibit a constant (˜90 MPa) higher yield strength than the high flux data. However, this difference cannot be explained from a flux effect but most probably from differences in the initial tensile properties. The hardening kinetic of both low and high flux is the same. Annealing at low temperature, 345 °C/40 h, to eventually reveal unstable matrix damage did not affect both BR2 and surveillance specimens. This is confirmed by other annealing experimental data including both tensile and hardness measurements and tensile data on A508 forging and weld. It is suggested that the absence of flux effect on the tensile properties while different radiation-induced microstructures can be attributed to thermal ageing effects.

  9. Alternative method for thermal neutron flux measurements based on common boric acid as converter and Lr-15 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, D.; Greaves, E. D.; Sajo B, L.; Barros, H. [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Apdo. Postal 89000, Caracas (Venezuela, Bolivarian Republic of); Ingles, R. [Universidad Nacional de San Antonio Abad del Cusco, Av. de la Cultura No. 733, Cusco (Peru)

    2010-02-15

    A method to determine the flux and angular distribution of thermal neutrons with the use of Lr-115 detectors was developed. The use of the Lr-115 detector involves the exposure of a pressed boric acid sample (tablet) as a target, in tight contact with the track detector, to a flux of thermalized neutrons. The self-absorption effects in thin films or foil type thermal neutron detectors can be neglected by using the Lr-115 detector and boric acid tablet setup to operate via backside irradiation. The energy window and the critical angle-residual energy curve were determined by comparisons between the experimental and simulated track parameters. A computer program was developed to calculate the detector registration efficiency, so that the thermal neutron flux can be calculated from the track densities induced in the Lr-115 detector using the derived empirical formula. The proposed setup can serves as directional detector of thermal neutrons. (Author)

  10. Neutron flux characterisation of the Pavia TRIGA Mark II research reactor for radiobiological and microdosimetric applications.

    Science.gov (United States)

    Alloni, D; Prata, M; Salvini, A; Ottolenghi, A

    2015-09-01

    Nowadays the Pavia TRIGA reactor is available for national and international collaboration in various research fields. The TRIGA Mark II nuclear research reactor of the Pavia University offers different in- and out-core neutron irradiation channels, each characterised by different neutron spectra. In the last two years a campaign of measurements and simulations has been performed in order to guarantee a better characterisation of these different fluxes and to meet the demands of irradiations that require precise information on these spectra in particular for radiobiological and microdosimetric studies. Experimental data on neutron fluxes have been collected analysing and measuring the gamma activity induced in thin target foils of different materials irradiated in different TRIGA experimental channels. The data on the induced gamma activities have been processed with the SAND II deconvolution code and finally compared with the spectra obtained with Monte Carlo simulations. The comparison between simulated and measured spectra showed a good agreement allowing a more precise characterisation of the neutron spectra and a validation of the adopted method. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Improved collision probability method for thermal-neutron-flux calculation in a cylindrical reactor cell

    International Nuclear Information System (INIS)

    Bosevski, T.

    1986-01-01

    An improved collision probability method for thermal-neutron-flux calculation in a cylindrical reactor cell has been developed. Expanding the neutron flux and source into a series of even powers of the radius, one' gets a convenient method for integration of the one-energy group integral transport equation. It is shown that it is possible to perform an analytical integration in the x-y plane in one variable and to use the effective Gaussian integration over another one. Choosing a convenient distribution of space points in fuel and moderator the transport matrix calculation and cell reaction rate integration were condensed. On the basis of the proposed method, the computer program DISKRET for the ZUSE-Z 23 K computer has been written. The suitability of the proposed method for the calculation of the thermal-neutron-flux distribution in a reactor cell can be seen from the test results obtained. Compared with the other collision probability methods, the proposed treatment excels with a mathematical simplicity and a faster convergence. (author)

  12. Thermal neutron flux measurements in the rotary specimen rack of the IPR-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rose Mary G. do Prado; Rodrigues, Rogério R.; Souza, Luiz Claudio A., E-mail: souzarm@cdtn.br, E-mail: rrr@cdtn.br, E-mail: lcas@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The thermal neutron flux in the rotary specimen rack of the IPR-R1 TRIGA reactor at the Nuclear Technology Development Center (CDTN), Belo Horizonte, Brazil, has been measured by the neutron activation method, using bare and cadmium covered gold foils. Those foils were irradiated in the rotary specimen rack with the reactor at 100 kW. The reactor core configuration has 63 fuel elements, composed of 59 original aluminum-clad elements and 4 stainless steel-clad fuel elements. The gamma activities of the foils were measured using Ge spectrometer. The perturbations of the thermal neutron flux caused by the introduction of an absorbing foil into the medium were considered in order to obtain accurate determination of the flux. The thermal neutron flux obtained was 7.4 x 10{sup 11} n.cm{sup -2}.s{sup -1}. (author)

  13. First result of deuterium retention in neutron-irradiated tungsten exposed to high flux plasma in TPE

    Science.gov (United States)

    Shimada, Masashi; Hatano, Y.; Calderoni, P.; Oda, T.; Oya, Y.; Sokolov, M.; Zhang, K.; Cao, G.; Kolasinski, R.; Sharpe, J. P.

    2011-08-01

    With the Japan-US joint research project Tritium, Irradiations, and Thermofluids for America and Nippon (TITAN), an initial set of tungsten samples (99.99% purity, A.L.M.T. Co.) were irradiated by high flux neutrons at 323 K to 0.025 dpa in High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). Subsequently, one of the neutron-irradiated tungsten samples was exposed to a high-flux deuterium plasma (ion flux: 5 × 1021 m-2 s-1, ion fluence: 4 × 1025 m-2) in the Tritium Plasma Experiment (TPE) at Idaho National Laboratory (INL). The deuterium retention in the neutron-irradiated tungsten was 40% higher in comparison to the unirradiated tungsten. The observed broad desorption spectrum from neutron-irradiated tungsten and associated TMAP modeling of the deuterium release suggest that trapping occurs in the bulk material at more than three different energy sites.

  14. Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations.

    Science.gov (United States)

    Nakano, Y; Yamazaki, A; Watanabe, K; Uritani, A; Ogawa, K; Isobe, M

    2014-11-01

    Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

  15. Awareness, Preference, Utilization, and Messaging Research for the Spallation Neutron Source and High Flux Isotope Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Rebecca [Bryant Research, LLC; Kszos, Lynn A [ORNL

    2011-03-01

    Oak Ridge National Laboratory (ORNL) offers the scientific community unique access to two types of world-class neutron sources at a single site - the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR). The 85-MW HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world, and the SNS is one of the world's most intense pulsed neutron beams. Management of these two resources is the responsibility of the Neutron Sciences Directorate (NScD). NScD commissioned this survey research to develop baseline information regarding awareness of and perceptions about neutron science. Specific areas of investigative interest include the following: (1) awareness levels among those in the scientific community about the two neutron sources that ORNL offers; (2) the level of understanding members of various scientific communities have regarding benefits that neutron scattering techniques offer; and (3) any perceptions that negatively impact utilization of the facilities. NScD leadership identified users of two light sources in North America - the Advanced Photon Source (APS) at Argonne National Laboratory and the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory - as key publics. Given the type of research in which these scientists engage, they would quite likely benefit from including the neutron techniques available at SNS and HFIR among their scientific investigation tools. The objective of the survey of users of APS, NSLS, SNS, and HFIR was to explore awareness of and perceptions regarding SNS and HFIR among those in selected scientific communities. Perceptions of SNS and FHIR will provide a foundation for strategic communication plan development and for developing key educational messages. The survey was conducted in two phases. The first phase included qualitative methods of (1) key stakeholder meetings; (2) online interviews with user administrators of APS and NSLS; and (3) one

  16. Calculations of the thermal and fast neutron fluxes in the Syrian miniature neutron source reactor using the MCNP-4C code.

    Science.gov (United States)

    Khattab, K; Sulieman, I

    2009-04-01

    The MCNP-4C code, based on the probabilistic approach, was used to model the 3D configuration of the core of the Syrian miniature neutron source reactor (MNSR). The continuous energy neutron cross sections from the ENDF/B-VI library were used to calculate the thermal and fast neutron fluxes in the inner and outer irradiation sites of MNSR. The thermal fluxes in the MNSR inner irradiation sites were also measured experimentally by the multiple foil activation method ((197)Au (n, gamma) (198)Au and (59)Co (n, gamma) (60)Co). The foils were irradiated simultaneously in each of the five MNSR inner irradiation sites to measure the thermal neutron flux and the epithermal index in each site. The calculated and measured results agree well.

  17. Investigation of some possible changes in Am-Be neutron source configuration in order to increase the thermal neutron flux using Monte Carlo code

    Science.gov (United States)

    Basiri, H.; Tavakoli-Anbaran, H.

    2018-01-01

    Am-Be neutrons source is based on (α, n) reaction and generates neutrons in the energy range of 0-11 MeV. Since the thermal neutrons are widely used in different fields, in this work, we investigate how to improve the source configuration in order to increase the thermal flux. These suggested changes include a spherical moderator instead of common cylindrical geometry, a reflector layer and an appropriate materials selection in order to achieve the maximum thermal flux. All calculations were done by using MCNP1 Monte Carlo code. Our final results indicated that a spherical paraffin moderator, a layer of beryllium as a reflector can efficiently increase the thermal neutron flux of Am-Be source.

  18. Energy distribution of the neutron flux measurements at the Chilean Reactor RECH-1 using multi-foil neutron activation and the Expectation Maximization unfolding algorithm.

    Science.gov (United States)

    Molina, F; Aguilera, P; Romero-Barrientos, J; Arellano, H F; Agramunt, J; Medel, J; Morales, J R; Zambra, M

    2017-11-01

    We present a methodology to obtain the energy distribution of the neutron flux of an experimental nuclear reactor, using multi-foil activation measurements and the Expectation Maximization unfolding algorithm, which is presented as an alternative to well known unfolding methods such as GRAVEL. Self-shielding flux corrections for energy bin groups were obtained using MCNP6 Monte Carlo simulations. We have made studies at the at the Dry Tube of RECH-1 obtaining fluxes of 1.5(4)×10 13 cm -2 s -1 for the thermal neutron energy region, 1.9(5)×10 12 cm -2 s -1 for the epithermal neutron energy region, and 4.3(11)×10 11 cm -2 s -1 for the fast neutron energy region. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Neutron flux calculations for the Rossendorf research reactor in (hex)- and (hex,z)-geometry using SNAP-3D

    International Nuclear Information System (INIS)

    Koch, R.; Findeisen, A.

    1986-04-01

    The multigroup neutron diffusion theory code SNAP-3D has been used to perform time independent neutron flux and power calculations of the 10 MW Rossendorf research reactor of the type WWR-SM. The report describes these calculations, as well as the actual reactor configuration, some details of the code SNAP-3D, and two- and three-dimensional reactor models. For evaluating the calculations some flux values and control rod worths have been compared with those of measurements. (author)

  20. New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions.

    Science.gov (United States)

    Geslot, B; Vermeeren, L; Filliatre, P; Lopez, A Legrand; Barbot, L; Jammes, C; Bréaud, S; Oriol, L; Villard, J-F

    2011-03-01

    Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 × 10(20) n∕cm(2). A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

  1. The neutron small-angle camera D11 at the high-flux reactor, Grenoble

    International Nuclear Information System (INIS)

    Ibel, K.

    1976-01-01

    The neutron small-angle scattering system at the high-flux reactor in Grenoble consists of three major parts: the supply of cold neutrons via bent neutron guides; the small-angle camera D11; and the data handling facilities. The camera D11 has an overall length of 80 m. The effective length of the camera is variable. The full length of the collimator before the fixed sample position can be reduced by movable neutron guides; the second flight path of 40 m full length contains detector sites in various positions. Thus a large range of momentum transfers can be used with the same relative resolution. Scattering angles between 5 x 10 -4 and 0.5 rad and neutron wavelengths from 0.2 to 2.0 nm are available. A large-area position-sensitive detector is used which allows simultaneous recording of intensities scattered at different angles; it is a multiwire proportional chamber. 3808 elements of 1 cm 2 are arranged in a two-dimensional matrix. (Auth.)

  2. High-flux neutron source based on a liquid-lithium target

    Science.gov (United States)

    Halfon, S.; Feinberg, G.; Paul, M.; Arenshtam, A.; Berkovits, D.; Kijel, D.; Nagler, A.; Eliyahu, I.; Silverman, I.

    2013-04-01

    A prototype compact Liquid Lithium Target (LiLiT), able to constitute an accelerator-based intense neutron source, was built. The neutron source is intended for nuclear astrophysical research, boron neutron capture therapy (BNCT) in hospitals and material studies for fusion reactors. The LiLiT setup is presently being commissioned at Soreq Nuclear research Center (SNRC). The lithium target will produce neutrons through the 7Li(p,n)7Be reaction and it will overcome the major problem of removing the thermal power generated by a high-intensity proton beam, necessary for intense neutron flux for the above applications. The liquid-lithium loop of LiLiT is designed to generate a stable lithium jet at high velocity on a concave supporting wall with free surface toward the incident proton beam (up to 10 kW). During off-line tests, liquid lithium was flown through the loop and generated a stable jet at velocity higher than 5 m/s on the concave supporting wall. The target is now under extensive test program using a high-power electron-gun. Up to 2 kW electron beam was applied on the lithium flow at velocity of 4 m/s without any flow instabilities or excessive evaporation. High-intensity proton beam irradiation will take place at SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator currently in commissioning at SNRC.

  3. The HB-2D Polarized Neutron Development Beamline at the High Flux Isotope Reactor

    Science.gov (United States)

    Crow, Lowell; Hamilton, WA; Zhao, JK; Robertson, JL

    2016-09-01

    The Polarized Neutron Development beamline, recently commissioned at the HB-2D position on the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, provides a tool for development and testing of polarizers, polarized neutron devices, and prototyping of polarized neutron techniques. With available monochromators including pyrolytic graphite and polarizing enriched Fe-57 (Si), the instrument has operated at 4.25 and 2.6 Å wavelengths, using crystal, supermirror, or He-3 polarizers and analyzers in various configurations. The Neutron Optics and Development Team has used the beamline for testing of He-3 polarizers for use at other HFIR and Spallation Neutron Source (SNS) instruments, as well as a variety of flipper devices. Recently, we have acquired new supermirror polarizers which have improved the instrument performance. The team and collaborators also have continuing demonstration experiments of spin-echo focusing techniques, and plans to conduct polarized diffraction measurements. The beamline is also used to support a growing use of polarization techniques at present and future instruments at SNS and HFIR.

  4. Measured and Predicted Neutron Flux Distributions in a Material Surrounding a Cylindrical Duct

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, J.; Sandlin, R.

    1966-03-15

    The radial fast neutron flux attenuations in the material (iron) surrounding ducts of diameters 7, 9, and 15 cm and total duct length of about 1.5 m have been investigated with and without neutron scattering cans filled with D{sub 2}O in the duct. Experimentally the problem was solved by the use of foil activation techniques. Theoretically it was attacked by, in the first place, a Monte Carlo program specially written for this purpose and utilizing an importance sampling technique. In the second place non- and single-scattering removal flux codes were tried, and also simple hand calculations. The Monte Carlo results accounted well for the fast flux attenuation, while the non- and single-scattering methods overestimated the attenuation generally by a factor of 10 or less. Simple hand calculations using three empirical parameters could be fitted to the measured data within a factor of 1.2 - 1.3 at penetration depths greater than 3 - 4 cm. The distribution of the D{sub 2}O-scattered flux could well be described in terms of single scattering.

  5. Absolute measurements of fluxes from Cassiopeia A, Cygnus A, Taurus A, Virgo A at seven wavelengths in the 1.8-4.2 cm band

    International Nuclear Information System (INIS)

    Dmitrenko, L.V.; Snegireva, V.V.; Turchin, V.I.; Tsejtlin, N.M.; Voronkov, L.A.; Dmitrenko, D.A.; Kuznetsova, N.A.; Kholodilov, N.N.

    1981-01-01

    Results of absolute measurements of fluxes from Cassiopeia A, Cygnus A, Taurus A, Virgo A at 1.8-4.17 cm wavelengths are presented. Spectra are built in the wave range of 1.8-100 cm with the use of results obtained earlier. Variability has been detected in radiation of Taurus A as well as ''steps'' in the spectrum of Taurus A with the spectral index α=0 in the region of 2 cm and 3-4 cm [ru

  6. Uncertainties in measuring trace amounts of cobalt and europium with low-flux neutron activation analysis

    Directory of Open Access Journals (Sweden)

    Burnham Steven

    2017-01-01

    Full Text Available Neutron activation analysis is widely used for identification of elements and their quantities even in trace amounts in the samples of almost any type. The challenges in detecting trace amounts of particular elements are often associated with the neutron flux produced at the research reactors. Low-flux neutron activation analysis usually presents the biggest challenge when analyzing trace quantities of elements with lower magnitude of radiative capture cross-sections. In this paper, we present the methodology and the quantified uncertainties associated with the detection of trace amounts of cobalt and europium, using as an example concrete aggregates. Recent growing interest is in improving structural concrete (increasing its strength but reducing its activation in nuclear power plant environments. Aside from buildings, structural concrete is also used as a biological shield in nuclear power plant that become radioactive after exposure to neutron flux. Due to radiative capture interactions, artificial radionuclides are generated to high enough concentrations that classify concrete as low-level radioactive waste at the time of the plant's decommissioning. Disposal of this concrete adds to the expense of nuclear power plant financing and its construction. Three radionuclides, 60Co, 152Eu, and 154Eu, account for 99 % of total residual radioactivity of nuclear power plant decommissioned concrete. IAEA document RS-G-1.7, Application of the Concepts of Exclusion, Exemption, and Clearance, specifies clearance levels of radionuclides specific activities: a specific activity lower than 0.1 Bqg-1 for 60Co and 152Eu, and 154Eu allows for a concrete to be recycled after decommissioning of the nuclear power plant. Therefore, low-flux neutron activation analysis is used to test the detection limits of trace elements in samples of cement, coarse, and fine concrete aggregates. These samples are irradiated at the University of Utah's 100 kW TRIGA Reactor at

  7. Numeric modeling of HfO2 neutron flux sensor parameters during sensor burnup in the RBMK-1500 reactor

    International Nuclear Information System (INIS)

    Jurkevicius, A.; Remeikis, V.

    2001-01-01

    The isotopic composition of hafnium in the radial neutron flux sensor of the RBMK-1500 reactor, the rates of the neutron absorption on Hf isotopes and the neutron spectrum in the sensor were numerically modeled. The sequence SAS2 (Shielding Analysis Sequence) from the package SCALE 4.3 was used for calculations. It has been obtained that the main neutron absorber 167 Er isotope practically burns up completely at the 18 MW d/kgU burnup depth, and at that time the capture rate of thermal neutrons in erbium decreases ten-fold. The average neutron flux density was calculated 7.6*10 13 neutrons. Cm -2 S -1 in the RBMK-1500 reactor grating, when the nuclear fuel enriched with 235 U by 2.4% and with Er by 0.4% is used in a fuel assembly. When the sensor burnup reaches 28 MW d/kgU, the neutron absorption rate of 178 Hf exceeds the rate of 177 Hf. The overall neutron absorption rate in hafnium decreases 2.53 times due to the sensor burnup to 56 MW d/kgU. The corrective factors ξ d (I) at different integral flux I of the sensors were calculated. The obtained dependence ξ d (I) calculated numerically was compared to the experimental one determined by processing repeated calibration results of Hf sensors in RBMK-1500 reactors, as well as compared to the theoretical one currently used in the Ignalina NPP special mathematical algorithms. (author)

  8. A benchmark analysis of radiation flux distribution for Boron Neutron Capture Therapy of canine brain tumors

    International Nuclear Information System (INIS)

    Moran, J.M.

    1992-02-01

    Calculations of radiation flux and dose distributions for Boron Neutron Capture Therapy (BNCT) of brain tumors are typically performed using sophisticated three-dimensional analytical models based on either a homogeneous approximation or a simplified few-region approximation to the actual highly-heterogeneous geometry of the irradiation volume. Such models should be validated by comparison with calculations using detailed models in which all significant macroscopic tissue heterogeneities and geometric structures are explicitly represented as faithfully as possible. This work describes a validation exercise for BNCT of canine brain tumors. Geometric measurements of the canine anatomical structures of interest for this work were performed by dissecting and examining two essentially identical Labrador Retriever heads. Chemical analyses of various tissue samples taken during the dissections were conducted to obtain measurements of elemental compositions for tissues of interest. The resulting geometry and tissue composition data were then used to construct a detailed heterogeneous calculational model of the Labrador Retriever head. Calculations of three-dimensional radiation flux distributions pertinent to BNCT were performed for the model using the TORT discrete-ordinates radiation transport code. The calculations were repeated for a corresponding volume-weighted homogeneous tissue model. Comparison of the results showed that the peak neutron and photon flux magnitudes were quite similar for the two models (within 5%), but that the spatial flux profiles were shifted in the heterogeneous model such that the fluxes in some locations away from the peak differed from the corresponding fluxes in the homogeneous model by as much as 10-20%. Differences of this magnitude can be therapeutically significant, emphasizing the need for proper validation of simplified treatment planning models

  9. A benchmark analysis of radiation flux distribution for Boron Neutron Capture Therapy of canine brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Moran, J.M.

    1992-02-01

    Calculations of radiation flux and dose distributions for Boron Neutron Capture Therapy (BNCT) of brain tumors are typically performed using sophisticated three-dimensional analytical models based on either a homogeneous approximation or a simplified few-region approximation to the actual highly-heterogeneous geometry of the irradiation volume. Such models should be validated by comparison with calculations using detailed models in which all significant macroscopic tissue heterogeneities and geometric structures are explicitly represented as faithfully as possible. This work describes a validation exercise for BNCT of canine brain tumors. Geometric measurements of the canine anatomical structures of interest for this work were performed by dissecting and examining two essentially identical Labrador Retriever heads. Chemical analyses of various tissue samples taken during the dissections were conducted to obtain measurements of elemental compositions for tissues of interest. The resulting geometry and tissue composition data were then used to construct a detailed heterogeneous calculational model of the Labrador Retriever head. Calculations of three-dimensional radiation flux distributions pertinent to BNCT were performed for the model using the TORT discrete-ordinates radiation transport code. The calculations were repeated for a corresponding volume-weighted homogeneous tissue model. Comparison of the results showed that the peak neutron and photon flux magnitudes were quite similar for the two models (within 5%), but that the spatial flux profiles were shifted in the heterogeneous model such that the fluxes in some locations away from the peak differed from the corresponding fluxes in the homogeneous model by as much as 10-20%. Differences of this magnitude can be therapeutically significant, emphasizing the need for proper validation of simplified treatment planning models.

  10. A comparative study of the neutron flux spectra in the MNSR irradiation sites for the HEU and LEU cores using the MCNP4C code.

    Science.gov (United States)

    Dawahra, S; Khattab, K; Saba, G

    2015-10-01

    A comparative study for fuel conversion from the HEU to LEU in the Miniature Neutron Source Reactor (MNSR) has been performed in this paper using the MCNP4C code. The neutron energy and lethargy flux spectra in the first inner and outer irradiation sites of the MNSR reactor for the existing HEU fuel (UAl4-Al, 90% enriched) and the potential LEU fuels (U3Si2-Al, U3Si-Al, U9Mo-Al, 19.75% enriched and UO2, 12.6% enriched) were investigated using the MCNP4C code. The neutron energy flux spectra for each group was calculated by dividing the neutron flux by the width of each energy group. The neutron flux spectra per unit lethargy was calculated by multiplying the neutron energy flux spectra for each energy group by the average energy of each group. The thermal neutron flux was calculated by summing the neutron fluxes from 0.0 to 0.625 eV, the fast neutron flux was calculated by summing the neutron fluxes from 0.5 MeV to 10 MeV for the existing HEU and potential LEU fuels. Good agreements have been noticed between the flux spectra for the potential LEU fuels and the existing HEU fuels with maximum relative differences less than 10% and 8% in the inner and outer irradiation sites. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. A sensitivity study on neutron flux variation due to 10B concentration in dose calculation for BNCT

    International Nuclear Information System (INIS)

    Jung, Sang Hoon

    2006-02-01

    The effects of inclusion of 10 B concentration on neutron flux and dose in dose calculation were studied. In order to provide the quantitative effects of inclusion of 10 B concentrations on depressions of neutron and photon flux and dose, the fluxes and doses with voxel head phantoms for various 10 B concentrations homogeneously distributed were calculated by using MCNPX simulations. A lithium target system and beam shaping assembly, which have been developed at the Hanyang University, were used as epithermal neutron beam. The calculation results show that the neutron flux at the center of the head phantom decreases by approximately 5.4% per 10 ppm of 10 B concentration in comparison with the neutron flux in the case of boron-free. It was also observed that the tissue dose at the center of the head phantom is depressed by approximately 4.7% per 10 ppm of the 10 B concentration and the tumor dose by approximately 5.3% per 10 ppm. According to depth of tumors, it was observed that the depressions of the doses in the tumors are ranged in 3.7 ∼ 9.2%. The dose calculations in the case of boron-free show that it is overestimated in comparison with the dose calculations in the cases of the inclusion of 10 B concentrations for the normal tissue and the tumors. Therefore, in dose calculation for BNCT, the depressions of neutron flux and dose should be considered. The results in this study are available to setting up the depression ratios which can be used for converting neutron and gamma fluxes and doses in phantom with boron free into the fluxes and doses in phantom with inclusion of 10 B concentrations in treatment. It is expected that the depression ratios is practicable to dose evaluation for BNCT

  12. Verification of Monte Carlo calculations of the neutron flux in typical irradiation channels of the TRIGA reactor, Ljubljana

    NARCIS (Netherlands)

    Jacimovic, R; Maucec, M; Trkov, A

    2003-01-01

    An experimental verification of Monte Carlo neutron flux calculations in typical irradiation channels in the TRIGA Mark II reactor at the Jozef Stefan Institute is presented. It was found that the flux, as well as its spectral characteristics, depends rather strongly on the position of the

  13. Use of CITATION code for flux calculation in neutron activation analysis with voluminous sample using an Am-Be source

    International Nuclear Information System (INIS)

    Khelifi, R.; Idiri, Z.; Bode, P.

    2002-01-01

    The CITATION code based on neutron diffusion theory was used for flux calculations inside voluminous samples in prompt gamma activation analysis with an isotopic neutron source (Am-Be). The code uses specific parameters related to the energy spectrum source and irradiation system materials (shielding, reflector). The flux distribution (thermal and fast) was calculated in the three-dimensional geometry for the system: air, polyethylene and water cuboidal sample (50x50x50 cm). Thermal flux was calculated in a series of points inside the sample. The results agreed reasonably well with observed values. The maximum thermal flux was observed at a distance of 3.2 cm while CITATION gave 3.7 cm. Beyond a depth of 7.2 cm, the thermal flux to fast flux ratio increases up to twice and allows us to optimise the detection system position in the scope of in-situ PGAA

  14. A Numerical Method for Obtaining Monoenergetic Neutron Flux Distributions and Transmissions in Multiple-Region Slabs

    Science.gov (United States)

    Schneider, Harold

    1959-01-01

    This method is investigated for semi-infinite multiple-slab configurations of arbitrary width, composition, and source distribution. Isotropic scattering in the laboratory system is assumed. Isotropic scattering implies that the fraction of neutrons scattered in the i(sup th) volume element or subregion that will make their next collision in the j(sup th) volume element or subregion is the same for all collisions. These so-called "transfer probabilities" between subregions are calculated and used to obtain successive-collision densities from which the flux and transmission probabilities directly follow. For a thick slab with little or no absorption, a successive-collisions technique proves impractical because an unreasonably large number of collisions must be followed in order to obtain the flux. Here the appropriate integral equation is converted into a set of linear simultaneous algebraic equations that are solved for the average total flux in each subregion. When ordinary diffusion theory applies with satisfactory precision in a portion of the multiple-slab configuration, the problem is solved by ordinary diffusion theory, but the flux is plotted only in the region of validity. The angular distribution of neutrons entering the remaining portion is determined from the known diffusion flux and the remaining region is solved by higher order theory. Several procedures for applying the numerical method are presented and discussed. To illustrate the calculational procedure, a symmetrical slab ia vacuum is worked by the numerical, Monte Carlo, and P(sub 3) spherical harmonics methods. In addition, an unsymmetrical double-slab problem is solved by the numerical and Monte Carlo methods. The numerical approach proved faster and more accurate in these examples. Adaptation of the method to anisotropic scattering in slabs is indicated, although no example is included in this paper.

  15. Characterisation of CVD diamond detectors used for fast neutron flux monitoring

    CERN Document Server

    Foulon, F; Amosov, V N; Kaschuck, Y; Frunze, V; Tromson, D; Brambilla, A

    2002-01-01

    Natural diamond detectors (NDD) have been successfully used for fast neutron spectrometry on various fusion installations in plasma diagnostics. These detectors can work at high temperature, are radiation hard and exhibit a high energy resolution. However, the use of NDD is limited by the availability of IIa type diamonds exhibiting high electronic properties. With the recent advance in the growth of high quality chemically vapour deposited (CVD) diamond at LETI, CVD diamond appears to be a very promising material for plasma diagnostics. We present here for the first time results of the use of CVD diamond detectors for fast neutron flux monitoring on a neutron generator. The characteristics of CVD diamond detectors are compared with that of high quality NDD made by TRINITI. Pulse height spectra have been measured with CVD detectors and NDD under both 5.5 MeV alpha particles and 14.1 MeV neutrons. The quality of CVD diamond enables the recording of structured spectra allowing the distinction between the differ...

  16. Flux Gain for Next-Generation Neutron-Scattering Instruments Resulting From Improved Supermirror Performance

    International Nuclear Information System (INIS)

    Rehm, C.

    2001-01-01

    Next-generation spallation neutron source facilities will offer instruments with unprecedented capabilities through simultaneous enhancement of source power and usage of advanced optical components. The Spallation Neutron Source (SNS), already under construction at Oak Ridge National Laboratory and scheduled to be completed by 2006, will provide greater than an order of magnitude more effective source flux than current state-of-the-art facilities, including the most advanced research reactors. An additional order of magnitude gain is expected through the use of new optical devices and instrumentation concepts. Many instrument designs require supermirror (SM) neutron guides with very high critical angles for total reflection. In this contribution, they discuss how the performance of modern neutron scattering instruments depends on the efficiency of these supermirrors. They outline ideas for enhancing the performance of the SM coatings, particularly for improving the reflectivity at the position of the critical wave vector transfer. A simulation program has been developed which allows different approaches for SM designs to be studied. Possible instrument performance gains are calculated for the example of the SNS reflectometer

  17. Mock-up experiment at Birmingham University for BNCT project of Osaka University--Neutron flux measurement with gold foil.

    Science.gov (United States)

    Tamaki, S; Sakai, M; Yoshihashi, S; Manabe, M; Zushi, N; Murata, I; Hoashi, E; Kato, I; Kuri, S; Oshiro, S; Nagasaki, M; Horiike, H

    2015-12-01

    Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Large-area self-powered neutron-detectors for neutron-flux measurements in HTRs. Status of developmental work

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Serpekian, T.; Benninghofen, G.; Serafin, N.; Spillekothen, H.G.

    1982-06-01

    The development is described of the large-area SPN-detector as an out of core power monitoring system. Gadolinium or cobalt was used as the emitter. Response functions of the gadolinium SPN-detector were found with regard to the reactor power, the effect of the gamma field, its short-term behaviour following reactor shutdown and long-term behaviour during reactor operation. It was shown that a detector of 0.1 mm emitter thickness can withstand an integral thermal neutron flux of 2.10 20 nvt almost without efficiency loss thus indicating that the large-area gadolinium SPN-detector is a suitable means for power monitoring in large HTGR's

  19. Influence of neutron flux, frequency and temperature to electrical impedance of nano silica particles

    Directory of Open Access Journals (Sweden)

    Elchin Huseynov

    2014-11-01

    Full Text Available We studied electric impedance of SiO2 nanomaterial at its initial state and after being exposed to continuous neutron irradiation for up to 20 hours. In doing so we employed a flux of neutrons of 2x1013 n⋅cm−2s−1 while the frequency and temperature ranges amounted to 0,09 – 2.3 MHz and 100 – 400 K correspondingly. Analysis in terms of the Cole-Cole expression revealed that with increasing irradiation period the polarization and relaxation times decrease as a result of combination of nanoparticles. Moreover, it is demonstrated that the electric conductivity of samples, on the other hand, increases with the increasing irradiation period. At low temperatures formations of clusters at three distinct states with different energies were resolved.

  20. Evaluation of neutron flux in the WWR-SM reactor channel and in the irradiating zone of U-150 cyclotron

    International Nuclear Information System (INIS)

    Sadikov, I.I.; Zinov'ev, V.G.; Sadikova, Z.O.; Salimov, M.I.

    2006-01-01

    Full text: For effective work of a reactor, and correct planning of experiments related to the reactor irradiation of various materials it is required to control a neutron flux in the given irradiation point for a long irradiation period. For realization of research works on topazes ennobling under irradiation by reactor neutrons as well as by secondary neutrons produced in a cyclotron it is necessary to know the total neutron flux and spectra. To resolve the problem a technique for registration of neutrons with different energy and calculation of a neutrons spectrum in the given irradiation points in reactor channels and in cyclotron behind the nickel target has been developed. Neutron flux density and energy spectra were monitored by use of the following nuclear reactions: 59 Co(n,γ) 60 Co, 197 Au(n,γ) 198 Au, 58 Ni(n,p) 58 Co, 24 Mg(n,p) 24 Na, 48 Ti(n,p) 48 Sc, 46 Ti(n,p) 46 Sc, 54 Fe(n,p) 54 Mn, 89 Y(n,2n) 88 Y, 60 Ni(np) 60 Co. Gamma spectrometer composed of HPGe detector (Rel. Eff. - 15%) and Digital Spectra Analyzer DSA-1000 (Canberra Ind., USA) was used to measure gamma activity of irradiated samples. Acquired gamma spectra were processed by means of Genie 2000 standard software package. The σ(E) functions and neutron spectra were calculated by using the least squares method and approximating the tabular and experimental data with power polynomials. The developed technique was applied for the adjustment of the topazes irradiation regimes in the reactor core and under secondary neutrons flux from a nickel target in the cyclotron. The given technique allows to calculate a logarithmic spectrum of neutrons in a energy range from 0,025 eV up to 12 MeV with the uncertainty of about 10 %. (author)

  1. Analysis of traces at ORNL's new high-flux neutron activation laboratory

    International Nuclear Information System (INIS)

    Ricci, E.; Handley, T.H.; Dyer, F.F.

    1974-01-01

    The investigations are outlined, which are carried out in order to develop (preferably instrumental) methods for multielement analysis of various trace elements. For this reason a new High-Flux NAA Laboratory was constructed at ORNL's. A general review is given on the Laboratory, further some methods and applications are shown. In the field of comparator activation analysis comparative data are given on mercury determinations in various matrices, and on arsenic determination in grasshoppers. This later method was used to trace the transport of arsenic containing pesticides. Some data are given on absolute activation analysis of Na, Ci, Mn, Br, and Au, too. (K.A.)

  2. Visualization of Crust in Metallic Piping Through Real-Time Neutron Radiography Obtained with Low Intensity Thermal Neutron Flux

    Directory of Open Access Journals (Sweden)

    Leandro C. Luiz

    2017-06-01

    Full Text Available The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN/National Nuclear Energy Commission (CNEN reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows.

  3. Visualization of crust in metallic piping through real-time neutron radiography obtained with low intensity thermal neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Luiz, Leandro C.; Crispim, Verginia R. [Nuclear Engineering Program, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Ferreira, Francisco J. O. [National Nuclear Energy Commission, CNEN/IEN, Division Reactors, Rio de Janeiro (Brazil)

    2017-06-15

    The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN)/National Nuclear Energy Commission (CNEN) reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows.

  4. Visualization of crust in metallic piping through real-time neutron radiography obtained with low intensity thermal neutron flux

    International Nuclear Information System (INIS)

    Luiz, Leandro C.; Crispim, Verginia R.; Ferreira, Francisco J. O.

    2017-01-01

    The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN)/National Nuclear Energy Commission (CNEN) reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows

  5. Study of variation of materials patients room's door related of neutron flux iradiation

    Science.gov (United States)

    Nirmalasari, Yuliana Dian; Suparmi, A.; Sardjono, Y.

    2017-08-01

    The treatment chamber of patients has been simulating with MCNPX Code. Optimation of simulation design of Irradiation chamber is corresponding to ISO standards for 30 MeV cyclotron generator. The simulation has used the variation of door's materials that was applied at treatment room's door. The variation of materials was Stainless Steel 202 and Pb, the thickness Pb and stainless steel 202 with the thickness were 2 cm, respectively. Neutron flux that was radiated to stainless steel 202 in the sequence was 3.34195 × 105 n . Cm-2 s-1 and 8.41568 × 104 n . Cm-2 s-1, while for Pb was 4.01349 × 105 n . Cm-2 s-1 and 2.58058 × 104 n . Cm-2 s-1. The further, neutron flux that was radiated to Pb and stainless steel 202 with the thickness were 4 cm in sequence was 4.00601 × 105 n . Cm-2 s-1 and 1.71713 × 104 n . Cm-2 s-1 for Pb, while for SS 202 was 3.09925 × 105 n . Cm-2 s-1. From this ratio we concluded that material Pb absorbed higher neutron flux than material Stainless Steel 202. On the other hand, the cost of Pb was more expensive than Stainless Steel 202. In addition, the material Stainless Steel 202 was obtaine more easily than the material Pb. There fore to overcome the economics problem, can try to build the door with stainless still 202 sheet and Pb sheet together. The further, the neutron dose with 2 cm of thickness was 7.69603 × 10-2 Gy and 2.10623 × 10-2 Gy for SS 202, while for Pb was 4.19444 × 10-2 Gy and 1.50581 × 10-2 Gy. While the neutron dose with 4 cm of thickness for SS 202 was 9.39602 × 10-2 Gy and for Pb was 4.46541 × 10-2 Gy and 1.50502 × 10-2 Gy. We recommend that this simulation should be further optimized.

  6. Effect of neutron flux on the frequency dependencies of electrical conductivity of silicon nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Huseynov, E.; Garibli, A., E-mail: elchin.huse@yahoo.com [National Nuclear Research Center, Department of Nanotechnology and Radiation Material Science, 1073, Inshaatchilar pr. 4, Baku (Azerbaijan)

    2016-11-01

    It has been reviewed the frequency dependencies of electrical conductivity of nanoparticles affected by neutron flux at different times and initial state, at various constant temperatures such as 100, 200, 300 and 400 K. Measurements have been carried out at each temperature at the different 97 values of frequency in the 1 Hz - 1 MHz range. From interdependence between real and imaginary parts of electrical conductivity it has been determined the type of conductivity. Moreover, in the work it is given the mechanism of electrical conductivity according to the obtained results. (Author)

  7. Measurement and Analysis of the Neutron and Gamma-Ray Flux Spectra in a Neutronics Mock-Up of the HCPB Test Blanket Module

    International Nuclear Information System (INIS)

    Seidel, K.; Freiesleben, H.; Poenitz, E.; Klix, A.; Unholzer, S.; Batistoni, P.; Fischer, U.; Leichtle, D.

    2006-01-01

    The nuclear parameters of a breeding blanket, such as tritium production rate, nuclear heating, activation and dose rate, are calculated by integral folding of an energy dependent cross section (or coefficient) with the neutron (or gamma-ray) flux energy spectra. The uncertainties of the designed parameters are determined by the uncertainties of both the cross section data and the flux spectra obtained by transport calculations. Also the analysis of possible discrepancies between measured and calculated integral nuclear parameter represents a two-step procedure. First, the energy region and the amount of flux discrepancies has to be found out and second, the cross section data have to be checked. To this end, neutron and gamma-ray flux spectra in a mock-up of the EU Helium-Cooled Pebble Bed (HCPB) breeder Test Blanket Module (TBM), irradiated with 14 MeV neutrons, were measured and analysed by means of Monte Carlo transport calculations. The flux spectra were determined for the energy ranges that are relevant for the most important nuclear parameters of the TBM, which are the tritium production rate and the shielding capability. The fast neutron flux which determines the tritium production on 7 Li and dominates the shield design was measured by the pulse-height distribution obtained from an organic liquid scintillation detector. Simultaneously, the gamma-ray flux spectra were measured. The neutron flux at lower energies, down to thermal, which determines the tritium production on 6 Li, was measured with time-of-arrival spectroscopy. For this purpose, the TUD neutron generator was operated in pulsed mode (pulse width 10 μs, frequency 1 kHz) and the neutrons arriving at a 3 He proportional counter in the mock-up were recorded as a function of time after the source neutron pulse. The spectral distributions for the two positions in the mock-up, where measurements were carried out, were calculated with the Monte Carlo code MCNP, version 5, and nuclear data from the

  8. Neutron flux calculation and fluence in the encircling of the core and vessel of a reactor BWR

    International Nuclear Information System (INIS)

    Martinez C, E.

    2011-01-01

    One of the main objectives related to the safety of any nuclear power plant, including the nuclear power plant of Laguna Verde is to ensure the structural integrity of reactor pressure vessel. To identify and quantify the damage caused by neutron irradiation in the vessel of any nuclear reactor, it is necessary to know both the neutron flux and the neutron fluence that the vessel has been receiving during its operation lifetime, and that the damage observed by mechanical testing are products of microstructural effects induced by neutron irradiation; therefore, it is important the study and prediction of the neutron flux in order to have a better understanding of the damage that these materials are receiving. The calculation here described uses the DORT code, which solves the neutron transport equation in discrete ordinates in two dimensions (x-y, r-θ and r-z), according to a regulatory guide, it should make an approximation of the neutron flux in three dimensions by the so called synthesis method. It is called in that way because it achieves a representation of 3 Dimensional neutron flux combining or summarizing the fluxes calculated by DORT r-θ, r-z and r. This work presents the application of synthesis method, according to Regulatory Guide 1190, to determine the 3 Dimensional fluxes in internal BWR reactor using three different spatial meshes. The results of the neutron flux and fluence, using three different meshes in the directions r, θ and z were compared with results reported in the literature obtaining a difference not larger than 9.61%, neutron flux reached its maximum, 1.58 E + 12 n/cm 2 s, at a height H 4 (239.07 cm) and angle 32.236 o in the core shroud and 4.00 E + 09 n/cm 2 s at a height H 4 and angle 35.27 o in the inner wall of the reactor vessel, positions that are consistent to within ±10% over the ones reported in the literature. (Author)

  9. Determination and analysis of neutron flux distribution on radial Piercing beam port for utilization of Kartini research reactor

    International Nuclear Information System (INIS)

    Widarto

    2002-01-01

    Determination and analysis of neutron flux measurements on radial piercing beam port have been done as completion experimental data document and progressing on utilization of the Kartini research reactor purposes. The analysis and determination of the neutron flux have been carried out by using Au foils detector neutron activation analysis method which put on the radius of cross section (19 cm) and a long of radial piercing beam port (310 cm) Based on the calculation, distribution of the thermal neutron flux is around (8.3 ± 0.9) x 10 5 ncm -2 s -1 to (6.8 ± 0.5) x 10 7 ncm -2 s -1 and fast neutron is (5.0 ± 0.2) x 10 5 ncm -2 s -1 to (1.43 ± 0.6) x 10 7 ncm -2 s -1 . Analyzing by means of curve fitting method could be concluded that the neutron flux distribution on radial piercing beam port has profiled as a polynomial curve. (author)

  10. Method for measuring dose-equivalent in a neutron flux with an unknown energy spectra and means for carrying out that method

    Science.gov (United States)

    Distenfeld, Carl H.

    1978-01-01

    A method for measuring the dose-equivalent for exposure to an unknown and/or time varing neutron flux which comprises simultaneously exposing a plurality of neutron detecting elements of different types to a neutron flux and combining the measured responses of the various detecting elements by means of a function, whose value is an approximate measure of the dose-equivalent, which is substantially independent of the energy spectra of the flux. Also, a personnel neutron dosimeter, which is useful in carrying out the above method, comprising a plurality of various neutron detecting elements in a single housing suitable for personnel to wear while working in a radiation area.

  11. Analysis of JKT01 Neutron Flux Detector Measurements In RSG-GAS Reactor Using LabVIEW

    Science.gov (United States)

    Rokhmadi; Nur Rachman, Agus; Sujarwono; Taryo, Taswanda; Sunaryo, Geni Rina

    2018-02-01

    The RSG-GAS Reactor, one of the Indonesia research reactors and located in Serpong, is owned by the National Nuclear Energy Agency (BATAN). The RSG-GAS reactor has operated since 1987 and some instrumentation and control systems are considered to be degraded and ageing. It is therefore, necessary to evaluate the safety of all instrumentation and controls and one of the component systems to be evaluated is the performance of JKT01 neutron flux detector. Neutron Flux Detector JKT01 basically detects neutron fluxes in the reactor core and converts it into electrical signals. The electrical signal is then forwarded to the amplifier (Amplifier) to become the input of the reactor protection system. One output of it is transferred to the Main Control Room (RKU) showing on the analog meter as an indicator used by the reactor operator. To simulate all of this matter, a program to simulate the output of the JKT01 Neutron Flux Detector using LabVIEW was developed. The simulated data is estimated using a lot of equations also formulated in LabVIEW. The calculation results are also displayed on the interface using LabVIEW available in the PC. By using this simulation program, it is successful to perform anomaly detection experiments on the JKT01 detector of RSG-GAS Reactor. The simulation results showed that the anomaly JKT01 neutron flux using electrical-current-base are respectively, 1.5×,1.7× and 2.0×.

  12. Measurement of two-dimensional thermal neutron flux in a water phantom and evaluation of dose distribution characteristics

    International Nuclear Information System (INIS)

    Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Horiguchi, Yoji

    2001-03-01

    To evaluate nitrogen dose, boron dose and gamma-ray dose occurred by neutron capture reaction of the hydrogen at the medical irradiation, two-dimensional distribution of the thermal neutron flux is very important because these doses are proportional to the thermal neutron distribution. This report describes the measurement of the two-dimensional thermal neutron distribution in a head water phantom by neutron beams of the JRR-4 and evaluation of the dose distribution characteristic. Thermal neutron flux in the phantom was measured by gold wire placed in the spokewise of every 30 degrees in order to avoid the interaction. Distribution of the thermal neutron flux was also calculated using two-dimensional Lagrange's interpolation program (radius, angle direction) developed this time. As a result of the analysis, it was confirmed to become distorted distribution which has annular peak at outside of the void, though improved dose profile of the deep direction was confirmed in the case which the radiation field in the phantom contains void. (author)

  13. Measurement and calculation of spatial and energetic neutron flux in the IEA-R1 reactor core

    International Nuclear Information System (INIS)

    Bittelli, U.D.

    1988-01-01

    This work presents spatial and energetic flux distribution measured in the IEA-R1 reactor core. The thermal neutron flux was measured by gold activation foils (bare and covered with cadmium) in the fuel element number 108 (reaction: 197 Au(n,γ) 198 Au) at 451W overall reactor power. The fast neutron flux was measured by indium activation foils (reaction: 115 In(n,n') 115m In) in the fuel elements number 94 at 4510W overall reactor power. The neutron energy spectrum was adjusted by SAND II code with the data produced by the irradiation of seven activation detectors in the fuel element number 94 at 4510 W overall reactor power. The following reactions were used: 58 Fe(n,γ) 59 Fe, 232 Th(n,γ) 233 Th, 197 Au(n,γ) 198 Au, 59 Co(n,γ) 60 Co, 54 Fe(n,p) 54 Mn, 24 Mg(n,p) 24 Na, 47 Ti(n,p) 47 Sc, 48 Ti(n,p) 48 Sc and 115 In(n,n') 115m In. The experimental results compared to those obtained by CITATION (spatial distribution flux) and HAMMER (energetic distribution flux) code, showed good agreement. The results presented in this work are a good contribution for a better knowledge of spatial and energetic neutron flux distribution in the IEA-R1 reactor core, besides that the experimental procedure is easily applicable to another situations. (autor) [pt

  14. Performance testing of the neutron flux monitors from 10keV to 1MeV developed for BNCT: A preliminary study.

    Science.gov (United States)

    Guan, Xingcai; Manabe, Masanobu; Tamaki, Shingo; Sato, Fuminobu; Murata, Isao; Wang, Tieshan

    2017-07-01

    The neutron flux monitors from 10keV to 1MeV designed for boron neutron capture therapy (BNCT) were experimentally tested with prototype monitors in an appropriate neutron field produced at the intense deuterium-tritium neutron source facility OKTAVIAN of Osaka University, Japan. The experimental test results and related analysis indicated that the performance of the monitors was good and the neutron fluxes from 10keV to 1MeV of practical BNCT neutron sources can be measured within 10% by the monitors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

    Science.gov (United States)

    Bortolussi, S.; Protti, N.; Ferrari, M.; Postuma, I.; Fatemi, S.; Prata, M.; Ballarini, F.; Carante, M. P.; Farias, R.; González, S. J.; Marrale, M.; Gallo, S.; Bartolotta, A.; Iacoviello, G.; Nigg, D.; Altieri, S.

    2018-01-01

    University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been carried out, aimed at characterizing the neutron spectrum and the gamma dose component. The neutron spectrum has been measured by means of multifoil neutron activation spectrometry and a least squares unfolding algorithm; gamma dose was measured using alanine dosimeters. Results show that in a reference position the thermal neutron flux is (1.20 ± 0.03) ×1010 cm-2 s-1 when the reactor is working at the maximum power of 250 kW, with the epithermal and fast components, respectively, 2 and 3 orders of magnitude lower than the thermal component. The ratio of the gamma dose with respect to the thermal neutron fluence is 1.2 ×10-13 Gy/(n/cm2).

  16. Analysis of Neutron Flux Distribution in Rsg-Gas Reactor With U-Mo Fuels

    Directory of Open Access Journals (Sweden)

    Taswanda Taryo

    2004-01-01

    Full Text Available The use of U-Mo fuels in research reactors seems to be promising and, recently, world researchers have carried out these such activities actively. The National Nuclear Energy Agency (BATAN which owns RSG-GAS reactor available in Serpong Research Center for Atomic Energy should anticipate this trend. It is, therefore, this research work on the use of U-Mo fuels in RSG-GAS reactor should be carried out. The work was focused on the analysis of neutron flux distribution in the RSG-GAS reactor using different content of molybdenum in U-Mo fuels. To begin with, RSG-GAS reactor core model was developed and simulated into X, Y and Z dimensions. Cross section of materials based on the developed cells of standard and control fuels was then generated using WIMS-D5-B. The criticality calculations were finally carried out applying BATAN-2DIFF code. The results showed that the neutron flux distribution obtained in U-Mo-fuel-based RSG-GAS core is very similar to those achieved in the 300-gram sillicide-fuel-based RSG-GAS reactor core. Indeed, the utilization of the U-Mo RSG-GAS core can be very similar to that of the high-density sillicide reactor core and even could be better in the future.

  17. Flux weighted method for solution of stiff neutron dynamic equations and its application

    International Nuclear Information System (INIS)

    Li Huiyun; Jiao Huixian

    1987-12-01

    To analyze reactivity event for nuclear power plants, it is necessary to solve the neutron dynamic equations, which is a group of typical stiff constant differential equations. Very small time steps could only be adopted when the group of equations is solved by common methods. However, a large time steps might be selected if the Flux Weighted Medthod introduced in this paper is used. Generally, weighted factor θ i1 is set as a constant. Naturally, this treatment method can decrease the accuracy of calculation for the increase of the steadiness of solving the equations. An accurate theoretical formula of 4 x 4 matrix of θ i1 is rigorously derived so that the accuracy of calculation is ensured, as well as the steadiness of solved equations is increased. This method have the advantage over classical Runge-kutta Method and other methods. The time steps could be increased by a factor of 1 ∼ 3 orders of magnitude so as to save a lot of computating time. The programe solving neutron dynamic equation, which is prepared by using Flux Weighted Method, could be sued for real time analog of training simulator, as well as for analysis and computation of reactivity event (including rod jumping out event)

  18. Neutron and Gamma Fluxes and dpa Rates for HFIR Vessel Beltline Region (Present and Upgrade Designs)

    Energy Technology Data Exchange (ETDEWEB)

    Blakeman, E.D.

    2001-01-11

    The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) is currently undergoing an upgrading program, a part of which is to increase the diameters of two of the four radiation beam tubes (HB-2 and HB-4). This change will cause increased neutron and gamma radiation dose rates at and near locations where the tubes penetrate the vessel wall. Consequently, the rate of radiation damage to the reactor vessel wall at those locations will also increase. This report summarizes calculations of the neutron and gamma flux (particles/cm{sup 2}/s) and the dpa rate (displacements/atom/s) in iron at critical locations in the vessel wall. The calculated dpa rate values have been recently incorporated into statistical damage evaluation codes used in the assessment of radiation induced embrittlement. Calculations were performed using models based on the discrete ordinates methodology and utilizing ORNL two-dimensional and three-dimensional discrete ordinates codes. Models for present and proposed beam tube designs are shown and their results are compared. Results show that for HB-2, the dpa rate in the vessel wall where the tube penetrates the vessel will be increased by {approximately}10 by the proposed enlargement. For HB-4, a smaller increase of {approximately}2.6 is calculated.

  19. Use of higher order signal moments and high speed digital sampling technique for neutron flux measurements

    Science.gov (United States)

    Baers, L. B.; Gutierrez, T. Rivero; Mendoza, R. A. Carrillo; Santana, G. Jimenez

    1993-08-01

    The second (conventional variance or Campbell signal), the third, and the modified fourth order central signal moments associated with the amplified and filtered currents from two electrodes of an ex-core neutron sensitive fission detector were measured versus the reactor power of the 1-MW TRIGA reactor in Mexico City. Two channels of a high-speed (400-MHz) multiplexing data sampler and an analog-to-digital converter with 12-b resolution and 1-Mword buffer memory were used. The data were further retrieved into a PC, and estimates for autocorrelation and cross-correlation moments up to the fifth order, coherence, skewness, excess, etc., quantities were calculated offline. Five-mode operation of the detector was achieved, including conventional counting rates and currents in agreement with theory and the authors' previous results with analog techniques. The signals are proportional to the neutron flux and reactor power in some flux ranges. The suppression of background noise is improved and the lower limit of the measurement range is extended as the order of moment is increased, in agreement with theory.

  20. Calculation of gamma-rays and fast neutrons fluxes with the program Mercure-4

    International Nuclear Information System (INIS)

    Baur, A.; Dupont, C.; Totth, B.

    1978-01-01

    The program MERCURE-4 evaluates gamma ray or fast neutron attenuation, through laminated or bulky three-dimensionnal shields. The method used is that of line of sight point attenuation kernel, the scattered rays being taken into account by means of build-up factors for γ and removal cross sections for fast neutrons. The integration of the point kernel over the range of sources distributed in space and energy, is performed by the Monte-Carlo method, with an automatic adjustment of the importance functions. Since it is operationnal the program MERCURE-4 has been intensively used for many various problems, for example: - the calculation of gamma heating in reactor cores, control rods and shielding screens, as well as in experimental devices and irradiation loops; - the evaluation of fast neutron fluxes and corresponding damage in structural materials of reactors (vessel steels...); - the estimation of gamma dose rates on nuclear instrumentation in the reactors, around the reactor circuits and around spent fuel shipping casks

  1. Activation analysis of stainless steel flux monitors using 252Cf neutron sources

    International Nuclear Information System (INIS)

    Williams, J.G.; Newton, T.H. Jr.; Cogburn, C.O.

    1984-01-01

    Activation analysis was performed on stainless steel beads from a chain which is used in reactor pressure vessel surveillance experiments at the Arkansas Power and Light Company reactors. The beads allow monitoring of two fast and three thermal neutron induced reactions: 58 Ni(n,p) 58 Co, 54 Fe(n,p) 54 Mn, 58 Fe(n,γ) 59 Fe, 59 Co(n,γ) 60 Co and 50 Cr(n,γ) 51 Cr. The analysis was performed using 12 beads from various positions along 5 different batches of chain and standard materials in an H 2 O moderator tank using two intense californium sources which had a total neutron emission rate of 3.97 x 10 10 /s. Semiconductor gamma spectrometers were used to count the products of the above reactions in the specimens. The percentage by weight of the iron, chromium and cobalt in the beads were found to be 62.1%, 20.2% and 0.120%, respectively. The excellent uniformity found in the bead compositions demonstrates the reproducibility of the experimental techniques and enhances considerably the value of the beads as neutron flux montitors

  2. Thermoluminescent dosemeters (TLD) exposed to high fluxes of gamma radiation, thermal neutrons and protons

    International Nuclear Information System (INIS)

    Gambarini, G.; Martini, M.; Meinardi, F.; Raffaglio, C.; Salvadori, P.; Scacco, A.; Sichirollo, A.E.

    1996-01-01

    Thermoluminescent dosemeters (TLD), widely experimented and utilized in personal dosimetry, have some advantageous characteristics which induce one to employ them also in radiotherapy. The new radiotherapy techniques are aimed at selectively depositing a high dose in cancerous tissues. This goal is reached by utilising both conventional and other more recently proposed radiation, such as thermal neutrons and heavy charged particles. In these inhomogeneous radiation fields a reliable mapping of the spatial distribution of absorbed dose is desirable, and the utilized dosemeters have to give such a possibility without notably perturbing the radiation field with the materials of the dosemeters themselves. TLDs, for their small dimension and their tissue equivalence for most radiation, give good support in the mapping of radiation fields. After exposure to the high fluxes of therapeutic beams, some commercial TL dosemeters have shown a loss of reliability. An investigation has therefore be performed, both on commercial and on laboratory made phosphors, in order to investigate their behaviour in such radiation fields. In particular the thermal neutron and gamma ray mixed field of the thermal column of a nuclear reactor, of interest for Boron Neutron Capture Therapy (B.N.C.T.) and a proton beam, of interest for proton therapy, were considered. Here some results obtained with new TL phosphors exposed in such radiation fields are presented, after a short description of some radiation damage effect on commercial LiF TLDs exposed in the (n th ,γ) field of the thermal column of a reactor. (author)

  3. Average fast neutron flux in three energy ranges in the Quinta assembly irradiated by two types of beams

    Directory of Open Access Journals (Sweden)

    Strugalska-Gola Elzbieta

    2017-01-01

    Full Text Available This work was performed within the international project “Energy plus Transmutation of Radioactive Wastes” (E&T - RAW for investigations of energy production and transmutation of radioactive waste of the nuclear power industry. 89Y (Yttrium 89 samples were located in the Quinta assembly in order to measure an average high neutron flux density in three different energy ranges using deuteron and proton beams from Dubna accelerators. Our analysis showed that the neutron density flux for the neutron energy range 20.8 - 32.7 MeV is higher than for the neutron energy range 11.5 - 20.8 MeV both for protons with an energy of 0.66 GeV and deuterons with an energy of 2 GeV, while for deuteron beams of 4 and 6 GeV we did not observe this.

  4. Monte Carlo estimation of the influence of elastic scattering anisotropy on the neutron flux in a nuclear reactor cell

    International Nuclear Information System (INIS)

    Kocic, A.

    1974-01-01

    Anisotropy of neutron elastic scattering is a problem of special importance in solving the Boltzmann transport equation numerically. This is not the case when Monte Carlo method is applied. Estimation of the influence of elastic scattering anisotropy on the neutron flux is treated in order to justify the application of Monte Carlo method which is computer time consuming. Correlation procedure was applied for the study of this influence. One group case was used as an example to enable comparison of other methods

  5. Stability of interlinked neutron vortex and proton flux-tube arrays in a neutron star - II. Far-from-equilibrium dynamics

    Science.gov (United States)

    Drummond, L. V.; Melatos, A.

    2018-03-01

    The equilibrium configurations of neutron superfluid vortices interacting with proton superconductor flux tubes in a rotating, harmonic trap are non-trivial in general, when the magnetorotational symmetry is broken. A non-zero angle θ between the magnetic and rotation axes leads to tangled vorticity due to competition between vortex-vortex repulsion and vortex-flux-tube pinning. Here, we investigate the far-from-equilibrium behaviour of the vortices, as the trap decelerates, by solving the time-dependent, stochastic, Gross-Pitaevskii equation numerically in three dimensions. The numerical simulations reveal new vortex behaviours. Key geometrical attributes of the evolving vortex tangle are characterized, as is the degree to which pinning impedes the deceleration of the neutron condensate as a function of η, the pinning strength, and θ. The simulated system is a partial analogue of the outer core of a decelerating neutron star, albeit in a very different parameter regime.

  6. Irradiation effects in fused quartz 'Suprasil' as a detector of fission fragments under high flux of reactor neutrons

    International Nuclear Information System (INIS)

    Moraes, O.M.G. de.

    1984-01-01

    A systematic study about the registration characteristics of synthetic fused quartz 'Suprasil I' use as a detector of fission fragments under high flux of reactor neutrons and the effects of irradiation on it was performed. Fission fragments of 252 Cf, gamma radiation doses of of 60 Co up to 150 MGy, and integrated neutrons fluxes up to 10 20 n/cm 2 were used. A model to explain the effects on track registration and development characteristics of 'Suprasil I' irradiated on reactors were proposed, based on the obtained results for efficiency an for annealing. (C.G.C.) [pt

  7. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  8. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. Neutron physics

    International Nuclear Information System (INIS)

    Beckurts, K.H.; Wirtz, K.

    1974-01-01

    This textbook consists of four sections which deal with the following subjects: 1. Production of neutrons and their interactions with the nuclei; neutron sources; neutron detectors; cross-section measurements. 2. Theory of neutron interactions with macroscopic media; neutron slowing down; space distribution of moderated neutrons; neutron thermalization; neutron scattering. 3. Radioactive probe measurements of thermal neutron fluxes; activation by means of epithermal neutrons; threshold detectors of fast neutrons; neutron calibration. 4. Neutron energy; slowing down kernels; neutron age; diffusion length and absorption of neutrons

  10. Upper limits to the quiet-time solar neutron flux from 10 to 100 MeV

    Science.gov (United States)

    Moon, S.; Simnett, G. M.; White, R. S.

    1976-01-01

    A large-area solid-angle double-scatter neutron telescope was flown to search for solar neutrons on three balloon flights in 1971 and 1972. The first two flights were launched from Palestine, Texas, and the third from Cape Girardeau, Missouri. The float altitude on each flight was at about 5 g/sq cm residual atmosphere. Neutrons from 10 to 100 MeV were measured. No solar flares occurred during the flights. Upper limits to the quiet-time solar neutron fluxes at the 95-per cent confidence level are 2.8, 4.6, 9.6, and 9.0 x 10 to the -4th power neutron/sq cm/sec in the energy intervals of 10-30, 30-50, 50-100, and 10-100 MeV, respectively.

  11. Neutronic characterization of cylindrical core of minor excess reactivity in the nuclear reactor IPEN/MB-01 from the measure of neutron flux distribution and its reactivity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Aredes, Vitor O.G.; Mura, Luiz E.C.; Santos, Diogo F. dos; Silva, Alexandre P. da, E-mail: ubitelli@ipen.br, E-mail: vitoraredes@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    When compared to a rectangular parallelepiped configuration the cylindrical configuration of a nuclear reactor core has a better neutron economy because in this configuration the probability of the neutron leakage is smaller, causing an increase in overall reactivity in the system to the same amount of fuel used. In this work we obtained a critical cylindrical configuration with the control rods 89.50% withdraw from the active region of the IPEN/MB-01 core. This is the cylindrical configuration minimum possible excess of reactivity. Thus we obtained a cylindrical configuration with a diameter of only 28 fuel rods with lowest possible excess of reactivity. For this purpose, 112 peripheral fuel rods are removed from standard reactor core (rectangular parallelepiped of 28x28 fuel rods). In this configuration the excesses of reactivity is approximated 279 pcm. From there, we characterize the neutron field by measuring the spatial distribution of the thermal and epithermal neutron flux for the reactor operating power of 83 watts measured by neutron noise analysis technique and 92.08± 0.07 watts measured by activation technique [10]. The values of thermal and epithermal neutron flux in different directions, axial, radial north-south and radial east-west, are obtained in the asymptotic region of the reactor core, away from the disturbances caused by the reflector and control bar, by irradiating thin gold foils infinitely diluted (1% Au - 99% Al) with and without (bare) cadmium cover. In addition to the distribution of neutron flux, the moderator temperature coefficient, the void coefficient, calibration of the control rods were measured. (author)

  12. Neutron metrology in the L.F.R. Neutron flux density spectrum in the inner graphite reflector of the L.F.R

    International Nuclear Information System (INIS)

    Zsolnay, E.M.

    1979-01-01

    The neutron spectrum in the vertical central plug of the Low Flux Reactor has been determined experimentally. Sets of activation and fission detectors have been irradiated, and the neutron spectrum has been unfolded with aid of 3 special computer programs SAND-II, RFSP-JUEL and CRYSTAL BALL. Using these 3 programs calculations are made on the improvement ratio, which is defined as the ratio of the variance of the input flux density to that of the output flux density. A Monte Carlo error analysis is made to examine the quality of the 3 solution spectra. The results obtained with the different computer codes were compared, and showed a general agreement. The experiment confirmed that the shape of the spectrum in the intermediate energy region is near the 1/E pattern. (author)

  13. Determination flux in the Reactor JEN-1; Medida de flujos de neutrones en el nucleo del Reactor JEN-1

    Energy Technology Data Exchange (ETDEWEB)

    Manas Diaz, L.; Montes Ponce de leon, J.

    1960-07-01

    This report summarized several irradiations that have been made to determine the neutron flux distributions in the core of the JEN-1 reactor. Gold foils of 380 {mu} gr and Mn-Ni (12% de Ni) of 30 mg have been employed. the epithermal flux has been determined by mean of the Cd radio. The resonance integral values given by Macklin and Pomerance have been used. (Author) 9 refs.

  14. Design of a new neutron delivery system for high flux source

    International Nuclear Information System (INIS)

    Boffy, Romain

    2016-01-01

    could expect, these drastic differences lead to their behaviour under thermal neutron flux. The results show that N-BK7 and S-BSL7 are structurally the most stable under radiation. Macroscopically, such stability results in the fact that these two materials show very slow swelling as a function of radiation dose. In contrast, the two other glasses are much more reactive. The whole glass structure compacts upon radiation. Specifically, the silica network and the boron units tend to blend, leading to an increase in density up to some saturation, followed by a very slow expansion of the same order as shown by N-BK7 and S-BSL7. Such findings allowed us to explain the drastic differences in the radiation limits for macroscopic surface splintering for these materials when they are used in neutron guides. (author)

  15. Optimization of the testing volumes with respect to neutron flux levels in the two-target high flux D-Li neutron source for the international fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Kelleher, W.P.; Varsamis, G.L.

    1989-01-01

    An economic and fusion-relevant source of high-energy neutrons is an essential element in the fusion nuclear technology and development program. This source can be generated by directing a high energy deuteron beam onto a flowing liquid lithium target, producing neutrons via the D-Lithium stripping reaction. Previous work on this type of source concentrated on a design employing one deuteron beam of modest amperage. This design was shown to have a relatively small testing volume with high flux gradients and was therefor considered somewhat unattractive from a materials testing standpoint. A design using two lithium targets and two high-amperage beams has recently been proposed. This two beam design has been examined in an effort to maximize the test volume while minimizing the flux gradients and minimizing the effect of radiation damage on one target due to the other. A spatial, energy and angle dependent neutron source modeling the D-Lithium source was developed. Using this source, a 3-dimensional map of uncollided flux within the test volume was calculated. The results showed that the target separation has little effect on the available experimental volume and that a testing volume of ∼35 liters is available with a volume averaged flux above 10 14 n/cm 2 /s. The collided flux within the test volume was then determined by coupling the source model with a Monte Carlo code. The spectral effects of the high-energy tail in the flux were examined and evaluated as to possible effects on materials response. Calculations comparing the radiation damage to materials from the D-Lithium source to that cause by a standard DT fusion first-wall neutron flux spectrum showed that the number of appm and dpa, as well as the ratio appm/dpa and dpa/MW/m 2 are within 30% for the two sources. 8 refs., 8 figs

  16. Determination, by neutron diffraction, of basic interaction forces for flux pinning in superconductors

    International Nuclear Information System (INIS)

    Lippmann, G.; Schelten, J.; Schmatz, W.

    1976-01-01

    A new method has been developed for the determination of the basic interaction force exerted on the flux lines in type II superconductors. From neutron diffraction by flux line lattices in the two-phase system Nb with Nb 2 N precipitates of a well defined metallurgical structure, it is observed that the flux lines are bent due to the presence of pinning centres. A measure for the bending is the width of the rocking curve which is rather directly related to the main basic interaction force (f 2 )sup(1/2). For four specimens with different number densities of precipitates from 1.3 x 10 17 to 1.3 x 10 18 m -3 the force (f 2 )sup(1/2) has been evaluated as a function of the flux density B from the angular widths of the measured rocking curves. These widths ranged from 6' to 4 0 . The basic interaction forces were independent of the number density; at B/Bsub(c2) = 0.5 a value (f 2 )sup(1/2) = 2 x 10 -10 N was obtained. The maximum interaction force K 0 obtained from the pinning force densities for one sample agreed well with (f 2 )sup(1/2). Reasonable agreements result from further comparisons of (f 2 )sup(1/2) with K 0 at B = 0 calculated from superconductivity parameters and also with K 0 S measured by Antesberger and Ullmaier (Antesberger, G. and Ullmaier, H.; 1974, Phil. Mag., vol. 29, 1101) on the alloy NbTa which has a precipitate structure similar to that of the Nb samples. (author)

  17. Analyzer of neutron flux in real time; Analizador de flujo neutronico en tiempo real

    Energy Technology Data Exchange (ETDEWEB)

    Rojas S, A.S.; Carrillo M, R.A.; Balderas, E.G. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    With base in the study of the real signals of neutron flux of instability events occurred in the Laguna Verde nuclear power plant where the nucleus oscillation phenomena of the reactor are in the 0 to 2.5 Hz range, it has been seen the possibility about the development a surveillance and diagnostic equipment capable to analyze in real time the behavior of nucleus in this frequencies range. An important method for surveillance the stability of the reactor nucleus is the use of the Power spectral density which allows to determine the frequencies and amplitudes contained in the signals. It is used an instrument carried out by LabVIEW graphic programming with a data acquisition card of 16 channels which works at Windows 95/98 environment. (Author)

  18. Infinite-dimensional observer theory for dynamic estimation of neutron flux and xenon distributions

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Ho; Cho, Nam Zin [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1991-07-01

    This paper describes a method for reconstructing the measurable and unmeasurable state variables in a nuclear reactor from output measurement data, which can be used to generate input of a feedback control system or to serve as a core observer (estimator) in reactor transient. The method is based on the Luenberger-type observer theory that is extended to infinite-dimensional distributed parameter systems. The method was applied to a simple reactor model in one spatial dimension and one energy group with xenon dynamics which exhibited spatial oscillations. The observer designed was tested by using model-based data for measurement output. The results showed that the spatial distributions of iodine, xenon and neutron flux were estimated by the observer very well using information from a finite number of sensors.

  19. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    CERN Document Server

    Murazaki, M; Uno, Y

    2003-01-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of +-13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, alpha, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and sup 3 He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, ...

  20. Determination of Reactivity and Neutron Flux Using Modified Neural Network for HTGR

    Directory of Open Access Journals (Sweden)

    M. Subekti

    2017-08-01

    Full Text Available Nuclear kinetic calculations based on point kinetic model have been generally applied as the standard method for neutronics codes. As the central control rod (C-CR withdrawal test has demonstrated in a prismatic core type high-temperature gas-cooled reactor (HTGR named High Temperature Engineering Test Reactor (HTTR, the transient calculation of kinetic parameter, reactivity, and neutron fluxes, requires a new method to shorten calculation-process time. Development of neural network method was applied to point kinetic model as the necessity of real-time calculation that could work in parallel with the digital reactivity meter. The combination of Time Delayed Neural Network (TDNN and Jordan Recurrent Neural Network (Jordan RNN named TD-Jordan RNN was the result of the modeling approach. The application of TD-Jordan RNN with adequate learning, tested offline, determined results accurately even when signal inputs were noisy. Furthermore, the preprocessing for neural network input utilized noise reduction as one of the equations to transform two of twelve time-delayed inputs into power corrected inputs.

  1. 232Th, 233Pa, and 234U capture cross-section measurements in moderated neutron flux

    Science.gov (United States)

    Bringer, O.; Isnard, H.; AlMahamid, I.; Chartier, F.; Letourneau, A.

    2008-07-01

    The Th-U cycle was studied through the evolution of a 100 μg 232Th sample irradiated in a moderated neutron flux of 8.010 14 n/cm 2/s, intensity close to that of a thermal molten salt reactor. After 43 days of irradiation and 6 months of cooling, a precise mass spectrometric analysis, using both TIMS and MC-ICP-MS techniques, was performed, according to a rigorous methodology. The measured thorium and uranium isotopic ratios in the final irradiated sample were then compared with integral simulations based on evaluated data; an overall good agreement was seen. Four important thermal neutron-capture cross-sections were also extracted from the measurements, 232Th (7.34±0.21 b), 233Pa (38.34±1.78 b), 234U (106.12±3.34 b), and 235U (98.15±11.24 b). Our 232Th and 235U results confirmed existing values whereas the cross-sections of 233Pa and 234U (both key parameters) have been redefined.

  2. Neutron-gamma flux and dose calculations in a Pressurized Water Reactor (PWR

    Directory of Open Access Journals (Sweden)

    Brovchenko Mariya

    2017-01-01

    Full Text Available The present work deals with Monte Carlo simulations, aiming to determine the neutron and gamma responses outside the vessel and in the basemat of a Pressurized Water Reactor (PWR. The model is based on the Tihange-I Belgian nuclear reactor. With a large set of information and measurements available, this reactor has the advantage to be easily modelled and allows validation based on the experimental measurements. Power distribution calculations were therefore performed with the MCNP code at IRSN and compared to the available in-core measurements. Results showed a good agreement between calculated and measured values over the whole core. In this paper, the methods and hypotheses used for the particle transport simulation from the fission distribution in the core to the detectors outside the vessel of the reactor are also summarized. The results of the simulations are presented including the neutron and gamma doses and flux energy spectra. MCNP6 computational results comparing JEFF3.1 and ENDF-B/VII.1 nuclear data evaluations and sensitivity of the results to some model parameters are presented.

  3. Neutron-gamma flux and dose calculations in a Pressurized Water Reactor (PWR)

    Science.gov (United States)

    Brovchenko, Mariya; Dechenaux, Benjamin; Burn, Kenneth W.; Console Camprini, Patrizio; Duhamel, Isabelle; Peron, Arthur

    2017-09-01

    The present work deals with Monte Carlo simulations, aiming to determine the neutron and gamma responses outside the vessel and in the basemat of a Pressurized Water Reactor (PWR). The model is based on the Tihange-I Belgian nuclear reactor. With a large set of information and measurements available, this reactor has the advantage to be easily modelled and allows validation based on the experimental measurements. Power distribution calculations were therefore performed with the MCNP code at IRSN and compared to the available in-core measurements. Results showed a good agreement between calculated and measured values over the whole core. In this paper, the methods and hypotheses used for the particle transport simulation from the fission distribution in the core to the detectors outside the vessel of the reactor are also summarized. The results of the simulations are presented including the neutron and gamma doses and flux energy spectra. MCNP6 computational results comparing JEFF3.1 and ENDF-B/VII.1 nuclear data evaluations and sensitivity of the results to some model parameters are presented.

  4. A new monitor set for the determination of neutron flux parameters in short-time k0-NAA

    Czech Academy of Sciences Publication Activity Database

    Kubešová, Marie; Kučera, Jan; Fikrle, Marek

    2011-01-01

    Roč. 656, č. 1 (2011), s. 61-64 ISSN 0168-9002 R&D Projects: GA ČR GA202/09/0363 Institutional research plan: CEZ:AV0Z10480505 Keywords : Short-time activation analysis * ko standartizacion * neutron flux parameters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.207, year: 2011

  5. Analytical evaluation of neutron diffusion equation for the geometry of very intense continuous high flux pulsed reactor

    International Nuclear Information System (INIS)

    Narain, Rajendra

    1995-01-01

    Using the concept of Very Intense Continuous High Flux Pulsed Reactor to obtain a rotating high flux pulse in an annular core an analytical treatment for the quasi-static solution with a moving reflector is presented. Under quasi-static situation, time averaged values for important parameters like multiplication factor, flux, leakage do not change with time. As a result the instantaneous solution can be considered to be separable in time and space after correcting for the coordinates for the motion of the pulser. The space behaviour of the pulser is considered as exp(-αx 2 ). Movement of delayed neutron precursors is also taken into account. (author). 4 refs

  6. The effect of cadmium shielding on the spatial neutron flux distribution inside one of the outer irradiation sites

    International Nuclear Information System (INIS)

    Shaaban, I.

    2009-06-01

    A permanent epithermal neutron irradiation facility was designed in the Syrian Miniature Neutron Source Reactor (MNSR) by using the cadmium (cylindrical vial 1.0 mm in thickness, 38.50 mm in diameter and 180 mm in length) as thermal neutron shielding material, for a permanent epithermal neutron activation analysis (ENAA). This site was designed by shielding the internal surface of the aluminum tube of the first outer irradiation site in the MNSR reactor. I was used the activation detectors 0.1143% Au-Al alloy foils with 0.1 mm thickness and 2.0 mm diameter for measurement the thermal neutron flux, epithermal and R c d=A b are/A c over ratio in the outer irradiation site. Distribution of the thermal neutron flux in the outer irradiation capsule has been found numerically using MCNP-4C code with and without cadmium shield, and experimentally by irradiating five copper wires using the outer irradiation capsule. Good agreements were obtained between the calculated and the measured results. (author)

  7. Comparison of neutron fluxes obtained by 2-D and 3-D geometry with different shielding libraries in biological shield of the TRIGA MARK II reactor

    International Nuclear Information System (INIS)

    Bozic, M.; Zagar, T.; Ravnik, M.

    2003-01-01

    Neutron fluxes in different spatial locations in biological shield are obtained with TORT code (TORT-Three Dimensional Oak Ridge Discrete Ordinates Neutron/Photon Transport Code). Libraries used with TORT code were BUGLE-96 library (coupled library with 47 neutron groups and 20 gamma groups) and VITAMIN-B6 library (coupled library with 199 neutron groups and 42 gamma groups). BUGLE-96 library is derived from VITAMIN-B6 library. 2-D and 3-D models for homogeneous type of problem (without inserted beam port 4) and problem with asymmetry (non-homogeneous problem; inserted beam port 4, filled with different materials) were of interest for neutron flux calculation. The main purpose is to verify the possibility for using 2-D approximation model instead of large 3-D model in some calculations. Another purpose of this paper was to compare neutron spectral constants obtained from neutron fluxes (3-D model) determined with smaller BUGLE-96 library with new constants obtained from fluxes calculated with bigger VITAMIN-B6 library. These neutron spectral constants are used in isotopic calculation with SCALE code package (ORIGEN-S). In past only neutron spectral constants determined by neutron fluxes from BUGLE-96 library were used. Experimental results used for isotopic composition comparison are available from irradiation experiment with selected type of concrete and other materials in beam port 4 (irradiation channel 4) in TRIGA Mark II reactor. These experimental results were used as a benchmark in this paper. (author)

  8. Methods and applications in high flux neutron imaging; Methoden und Anwendungen fuer bildgebende Verfahren mit hohen Neutronenfluessen

    Energy Technology Data Exchange (ETDEWEB)

    Ballhausen, H.

    2007-02-07

    This treatise develops new methods for high flux neutron radiography and high flux neutron tomography and describes some of their applications in actual experiments. Instead of single images, time series can be acquired with short exposure times due to the available high intensity. To best use the increased amount of information, new estimators are proposed, which extract accurate results from the recorded ensembles, even if the individual piece of data is very noisy and in addition severely affected by systematic errors such as an influence of gamma background radiation. The spatial resolution of neutron radiographies, usually limited by beam divergence and inherent resolution of the scintillator, can be significantly increased by scanning the sample with a pinhole-micro-collimator. This technique circumvents any limitations in present detector design and, due to the available high intensity, could be successfully tested. Imaging with scattered neutrons as opposed to conventional total attenuation based imaging determines separately the absorption and scattering cross sections within the sample. For the first time even coherent angle dependent scattering could be visualized space-resolved. New applications of high flux neutron imaging are presented, such as materials engineering experiments on innovative metal joints, time-resolved tomography on multilayer stacks of fuel cells under operation, and others. A new implementation of an algorithm for the algebraic reconstruction of tomography data executes even in case of missing information, such as limited angle tomography, and returns quantitative reconstructions. The setup of the world-leading high flux radiography and tomography facility at the Institut Laue-Langevin is presented. A comprehensive appendix covers the physical and technical foundations of neutron imaging. (orig.)

  9. Estimation of neutron flux and xenon distributions via observer-based control theory

    Energy Technology Data Exchange (ETDEWEB)

    Park, Y.H.; Cho, N.Z. (Korea Advanced Inst. of Science and Technology, Dept. of Nuclear Engineering, P.O. Box 150, Cheongryang, Seoul (KR))

    1992-05-01

    State feedback control provides many advantages, such as stabilization and improved transient response. However, when state feedback control is considered for spatial control of a nuclear reactor, it requires complete knowledge of the distributions of the system state variables. Also, if the reactor is in a transient, flux mapping systems that are based on steady-state conditions are not appropriate for an accurate representation of the operating state of the reactor. In this paper a method is described for reconstructing the measurable and unmeasurable state variables in a nuclear reactor from output measurement data, which can be used to generate input for a feedback control system or serve as a core observer (estimator) in a reactor transient. The method is based on a Luenberger-type observer theory that is extended to infinite-dimensional distributed parameter systems. The method was applied to a simple reactor model in one spatial dimension and one energy group with xenon dynamics that exhibited spatial oscillations. The resulting observer was tested by using model-based data for measurement output. The results show that the spatial distributions of iodine, xenon, and neutron flux are estimated very well be the observer using information from a finite number of sensors.

  10. Improvement in the calibration time of absolute emission rate of radioisotopic neutron sources using vanadyl sulfate bath

    International Nuclear Information System (INIS)

    Khabaz, Rahim

    2012-01-01

    In this study, for calibration of emission rate of radioisotopic neutron sources, a suitable vanadium salt was proposed instead manganese sulfate because the shorter half-life of 52 V would facilitate faster neutron yield measurements to be made with a shorter delay time between subsequent measurements. Using Monte Carlo method, different correction factors of manganese and vanadyl sulfate baths were calculated and compared with each other. The results showed that for having an appropriate efficiency of VBS, high concentrations of solution must be used. - Highlights: ► The widely used method for measurement of emission rate of radioisotopic neutron sources is MBS. ► One of limitations of MBS is time required for activation to saturation and background measurement. ► The aim of this study is to evaluate a calibration method by VBS with about one-hour full-cycle time. ► The relative efficiency per neutron of VBS was just about half that obtained from MBS. ► The relative efficiency of VBS is compensated with increasing the concentration of solution.

  11. Small angle neutron scattering on an absolute intensity scale and the internal surface of diatom frustules from three species of differing morphologies.

    Science.gov (United States)

    Garvey, C J; Strobl, M; Percot, A; Saroun, J; Haug, J; Vyverman, W; Chepurnov, V A; Ferris, J M

    2013-05-01

    The internal nanostructure of the diatoms Cyclotella meneghiniana, Seminavis robusta and Achnanthes subsessilis was investigated using small angle neutron scattering (SANS) to examine thin biosilica samples, consisting of isotropic (powder) from their isolated cell walls. The interpretation of SANS data was assisted by several other measurements. The N2 adsorption, interpreted within the Branuer-Emmet-Teller isotherm, yielded the specific surface area of the material. Fourier transform infrared (FTIR) and Raman spectroscopy indicates that the isolated material is amorphous silica with small amounts of organic cell wall materials acting as a filling material between the silica particles. A two-phase (air and amorphous silica) model was used to interpret small angle neutron scattering data. After correction for instrumental resolution, the measurements on two SANS instruments covered an extended range of scattering vectors 0.0011 nm(-1) scattering vectors, q, on an absolute scale of intensity for each sample. Each of the samples gave a characteristic scattering curve where log (intensity) versus log (q) has a -4 dependence, with other features superimposed. In the high-q regime, departure from this behaviour was observed at a length-scales equivalent to the proposed unitary silica particle. The limiting Porod scattering law was used to determine the specific area per unit of volume of each sample illuminated by the neutron beam. The Porod behaviour, and divergence from this behaviour, is discussed in terms of various structural features and the proposed mechanisms for the bio-assembly of unitary silica particles in frustules.

  12. Dependence of absolute photon flux on infrared absorbance alteration and surface roughness on photoresist polymers irradiated with vacuum ultraviolet photons emitted from HBr plasma

    Science.gov (United States)

    Zhang, Yan; Takeuchi, Takuya; Ishikawa, Kenji; Hayashi, Toshio; Takeda, Keigo; Sekine, Makoto; Hori, Masaru

    2017-12-01

    The absolute fluxes of vacuum ultraviolet (VUV) photons emitted from HBr plasma were analyzed and the effects of VUV photons on a photoresist polymer in ArF-excimer-laser (193 nm) lithography were quantitatively investigated on the basis of the infrared spectra attributed to the C=O region. The spectral peak intensity assigned to the methacrylic acid (MAA) in the photoresist drastically decreased owing to the loss of this monomer caused by the irradiation of VUV photons at dosages below 16 × 1016 photons/cm2. X-ray photoelectron spectroscopy observation showed that the removed monomer moved to the surface and generated volatile products that induced a decrease in film thickness. As a consequence, the surface became rough during the early-stage irradiation at dosages lower than 16 × 1016 photons/cm2 owing to the monomer loss of MAA with volatile product formation and subsequent cross-linking reactions.

  13. Low energy neutron background in deep underground laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Best, Andreas, E-mail: andreas.best@lngs.infn.it [INFN, Laboratori Nazionali del Gran Sasso (LNGS), 67100 Assergi (Italy); Department of Physics and The Joint Institute for Nuclear Astrophysics, University of Notre Dame, Notre Dame, IN 46556 (United States); Görres, Joachim [Department of Physics and The Joint Institute for Nuclear Astrophysics, University of Notre Dame, Notre Dame, IN 46556 (United States); Junker, Matthias [INFN, Laboratori Nazionali del Gran Sasso (LNGS), 67100 Assergi (Italy); Kratz, Karl-Ludwig [Department for Biogeochemistry, Max-Planck-Institute for Chemistry, 55020 Mainz (Germany); Laubenstein, Matthias [INFN, Laboratori Nazionali del Gran Sasso (LNGS), 67100 Assergi (Italy); Long, Alexander [Department of Physics and The Joint Institute for Nuclear Astrophysics, University of Notre Dame, Notre Dame, IN 46556 (United States); Nisi, Stefano [INFN, Laboratori Nazionali del Gran Sasso (LNGS), 67100 Assergi (Italy); Smith, Karl; Wiescher, Michael [Department of Physics and The Joint Institute for Nuclear Astrophysics, University of Notre Dame, Notre Dame, IN 46556 (United States)

    2016-03-11

    The natural neutron background influences the maximum achievable sensitivity in most deep underground nuclear, astroparticle and double-beta decay physics experiments. Reliable neutron flux numbers are an important ingredient in the design of the shielding of new large-scale experiments as well as in the analysis of experimental data. Using a portable setup of {sup 3}He counters we measured the thermal neutron flux at the Kimballton Underground Research Facility, the Soudan Underground Laboratory, on the 4100 ft and the 4850 ft levels of the Sanford Underground Research Facility, at the Waste Isolation Pilot Plant and at the Gran Sasso National Laboratory. Absolute neutron fluxes at these laboratories are presented.

  14. Flux calculations for the upgrade of the SANS facility at the Petten-reactor

    International Nuclear Information System (INIS)

    Uca, O.; Ohms, C.; Youtsos, A.G.

    2006-01-01

    The absolute flux at the sample position of the Small-Angle Neutron Scattering instrument is an important parameter in instrument construction. In this paper, analytical expressions are obtained to calculate the flux at the sample position. The used approach has been validated on different instruments. An increase of the flux with two orders of magnitude is foreseen after completion of the upgrade

  15. Evaluation of the current fast neutron flux monitoring instrumentation applied to LFR demonstrator ALFRED. Capabilities and limitations

    International Nuclear Information System (INIS)

    Lepore, Luigi; Remetti, Romolo; Cappelli, Mauro

    2015-01-01

    Among Gen IV projects for future nuclear power plants, Lead Fast Reactors (LFR) seem to be a very interesting solution due to their benefits in terms of fuel cycle, coolant-safety and waste management. The novelty of the matter causes some open issues about coolant chemical aspect, structural aspects, monitoring instrumentation, etc. Particularly hard neutron flux spectra would make traditional neutron instrumentation unfit to all reactor conditions, i.e. source, intermediate, and power range. Identification of new models of nuclear instrumentation specialized for LFR neutron flux monitoring asks for an accurate evaluation of the environment the sensor will work in. In this study, thermal-hydraulics and chemical conditions for LFR core environment will be assumed, as the neutron flux will be studied extensively by means of the Monte Carlo transport code MCNPX. The core coolant’s high temperature drastically reduces the candidate instrumentation, because only some kind of fission chambers and Self Powered Neutron Detectors can be operated in such an environment. This work aims to evaluate the capabilities of the available instrumentation (usually designed for Sodium Fast Reactors, SFRs) when exposed to the neutron spectrum derived from ALFRED, a pool-type small-power LFR project to demonstrate the feasibility of this technology into the European framework. This paper shows that such instruments do follow the power evolution, but they are not completely suitable to detect the whole range of reactor power. Some improvements are then possible in order to increase the signal-to-noise ratio, by optimizing each instrument in the range of reactor power, such to get the best solution. Some new detector designs are here proposed, and the possibilities for prototyping and testing by means of a fast reactor investigated. (author)

  16. Determination of nitrogen in wheat flour through Activation analysis using Fast neutron flux of a Thermal nuclear reactor

    International Nuclear Information System (INIS)

    Ramirez G, T.

    1976-01-01

    In this work is done a technical study for determining Nitrogen (protein) and other elements in wheat flour Activation analysis, with Fast neutrons from a Thermal nuclear reactor. Initially it is given an introduction about the basic principles of the methods of analysis. Equipment used in Activation analysis and a brief description of the neutron source (Thermal nuclear reactor). The realized experiments for determining the flux form in the irradiation site, the half life of N-13 and the interferences due to the sample composition are included too. Finally, the obtained results by Activation and the Kjeldahl method are tabulated. (Author)

  17. Summary of RETRAN calculations on La Salle 2 neutron flux oscillation event performed at JAERI

    International Nuclear Information System (INIS)

    Araya, Fumimasa; Hirano, Masashi; Yoshida, Kazuo; Matsumoto, Kiyoshi; Yokobayashi, Masao; Kohsaka, Atsuo

    1990-01-01

    This paper reviews the major results obtained from the analyses of the LaSalle 2 neutron flux oscillation event with the RETRAN code, which have been performed at Japan Atomic Energy Research Institute. A method to determine instability threshold was developed and applicability of the method was validated by thermal-hydraulic instability experiment analyses. The instability map specific to LaSalle 2 was drawn with the method. Also, the LaSalle 2 event was simulated and the calculated locus of the event was drawn on the instability map. By performing sensitivity calculations, effects of axial power distribution and radial power peaking on the stability was quantitatively determined within the scope of point nuclear kinetics model. The calculated results showed that the core inlet subcooling and the power distribution were important at the event. In conclusion: On the LaSalle 2 neutron flux oscillation event, a series of calculations was performed to obtain in-depth understanding of the phenomena involved in the event. As for the analyses of the instability experiments, the calculated trends were in good agreement with those of the experiments. This showed the method had applicability to the instability problem. As for the La Salle 2 event analyses, by plotting the calculated locus of the event on the instability map, it was shown that the oscillation started due that the core state entered into the unstable region according to the increase in core inlet subcooling. On the flow control operating map, it was shown that the operating region became covered by the unstable region in accordance with the increase in core inlet subcooling. As for the sensitivity calculations on the power distribution, it was shown that the power distribution had large effects on the instability boundary especially in the region of the non-dimensional power to flow ratio less than 0.5. It was also shown that the effects of the power distribution in the transient calculations with alternative

  18. Absolute efficiency response curves of a HpGe detector in the 60-1500 keV energy range for an Am-Be neutron induced prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Turhan, S.; Vural, M.; Cakir, I.T.; Demirel, H.; Demirbas, A.; Yucel, H.

    2004-01-01

    Full text: A 20 Ci 241 Am-Be neutron source has been used in conjunction with a n-type HPGe for prompt gamma-ray neutron activation analysis of some elements such as boron, carbon, nitrogen, gadolinium, samarium, etc. The characteristic absolute efficiency response curves of the detector for different sample geometries (point, ampoule and tube) in the presence of Li 2 CO 3 powder case and/or cadmium cap, which both have been used to shield detector against neutrons, have been measured in the energy range of 60-1500 keV by using mono-energetic and multi-gamma emitting radionuclide calibrated point and standard ampoule sources. All absolute efficiency measurements were carried out at a source-to-detector distance of 77,5 and 15 cm at which coincidence summing effects are negligible to reduce neutron and gamma-ray background in vicinity of detector used for PGA purposes

  19. Direct observation of current-induced flux flow in a type-II superconductor by neutron diffraction

    International Nuclear Information System (INIS)

    Schelten, J.; Ullmaier, H.; Lippmann, G.

    1975-01-01

    Lattice planes that are in reflection position at rest must be rotated in order to keep them reflecting when the lattice is moving. This principle was applied to observe the motion of flux lines caused by a transport current in an almost ideal type-II NbTa superconductor. The periodic arrangement of flux lines was found to persist up to transport currents 20 times larger than the critical current, corresponding to a mean flux velocity of 1 msec -1 . The velocities determined by neutron diffraction are in agreement with the value E/B, where E is the macroscopic electric field across a current-carrying superconductor and B is the flux density

  20. Determination of neutron fluxes at the self-shielded PET cyclotron and the electron liniac apparatus of Tokushima University Hospital using activation foil method

    International Nuclear Information System (INIS)

    Sakama, Minoru; Tanii, Takashi; Maezawa, Hiroshi; Saze, Takuya; Maeda, Kouji; Sato, Kazuo; Honda, Eiichi; Nishitani, Hiromu

    2008-01-01

    Up till now, from a radiation safety management point of view, it has been discussed to construct guidelines on estimation of neutron fluxes produced via operating various medical small accelerators and to establish uniformly the clearance system related to having neutron activation effects into each accelerator facility. That is, it was the aim of this investigation to accumulate the data on estimation basis of neutron flux measurements at those medical small accelerators by an activation foil method. In this work, the neutron fluxes at the self-shielded PET cyclotron and the electron liniac apparatus of Tokushima University Hospital have been measured as the medical small accelerator. As a result, for the self-shielded PET cyclotron, it was found that the thermal neutron flux is (1.04±0.05) x10 7 cm -2 s -1 and the fast neutron fluxes are distributed over the range 1x10 4 (the neutron energy E n =9 MeV) to 1x10 7 (E n =1.5 MeV) cm -2 s -1 into the radiation shelter, and while the thermal neutron fluxes would be distributed over the range 5.0x10 1 to 9.9x10 1 cm -2 s -1 and then the fast neutron dose leakages were not detected outside there. For the 6/10 MV electron liniac apparatus, it was also found that nearly the same thermal neutron fluxes would be distributed all around the liniac room and those measured values are over the range (1.01±0.18)x10 3 to (1.32±0.10)x10 3 cm -2 s -1 . (author)

  1. Neutron flux distribution inside the cylindrical core of minor excess of reactivity in the IPEN/MB-01 reactor and comparison with citation code and MCNP- 5 code

    Energy Technology Data Exchange (ETDEWEB)

    Aredes, Vitor Ottoni; Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto C.; Santos, Diogo Feliciano dos; Lima, Ana Cecilia de Souza, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This study aims to determine the distribution of thermal neutron flux in the IPEN/MB-01 nuclear reactor core assembled with cylindrical core configuration of minor excess of reactivity with 568 fuel rods (28 fuel rods in diameter). The thermal neutron flux at the positions of irradiation derive from the method of reaction rate using gold foils. The experiment consists in inserting gold activations foils with and without cadmium coverage (cadmium boxes with 0.0502 cm thickness) in several positions throughout the active core. After irradiation, activity induced by nuclear reaction rates over gold foils is assessed by gamma ray spectrometry using a high-purity germanium (HPGe) detector. Experimental results are compared to those derived from calculations performed using a three dimensional CITATION diffusion code and MCNP-5 code and a proper nuclear data library. While calculated neutron flux data shows good agreement with experimental values in regions with little disturbance in the neutron flux, also showing that in the region of the reflectors of neutrons and near the control rods, the diffusion theory is not very precise. The average value of thermal neutron flux obtained experimentally compared to the calculated value by CITATION code and MCNP-5 code respectively show a difference of 1.18% and 0.84% at a nuclear power level of 74.65 ± 3.28 % watts. The average measured value of thermal neutron flux is 4.10 10{sup 8} ± 5.25% n/cm{sup 2}s. (author)

  2. Neutron scattering from the flux-line lattice in Bi2Sr2CaCu2O8+#gamma#

    DEFF Research Database (Denmark)

    Paul, D.M.; Forgan, E.M.; Cubitt, R.

    1995-01-01

    Neutron small-angle diffraction has been used to investigate the flux-line lattice structure within single crystals of the high-temperature superconductor Bi2.15Sr1.95CaCu2O8+x. The diffracted intensity goes rapidly to zero as the magnetic field or the temperature is increased. Melting at low...... fields as a function of temperature coincides with the appearence of finite resistance within the superconducting state. At low temperatures the diffracted intensity disappears in fields greater than similar to 70 mT, probably due to the decomposition of the flux-line lattice into randomly pinned 2d...

  3. Neutron flux measurements at the TRIGA reactor in Vienna for the prediction of the activation of the biological shield.

    Science.gov (United States)

    Merz, Stefan; Djuricic, Mile; Villa, Mario; Böck, Helmuth; Steinhauser, Georg

    2011-11-01

    The activation of the biological shield is an important process for waste management considerations of nuclear facilities. The final activity can be estimated by modeling using the neutron flux density rather than the radiometric approach of activity measurements. Measurement series at the TRIGA reactor Vienna reveal that the flux density next to the biological shield is in the order of 10(9)cm(-2)s(-1) at maximum power; but it is strongly influenced by reactor installations. The data allow the estimation of the final waste categorization of the concrete according to the Austrian legislation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Disentanglement time of the crystallites in RPDM irradiated with a low neutron flux

    International Nuclear Information System (INIS)

    Mocellini, R.R.; Lambri, O.A.; Celauro, C.A.; Rodriguez Garraza, A.L.; Sorichetti, P.A.

    2006-01-01

    Electrical insulators of organic type are composed by a rigid nucleus of some type of epoxy resin and for a housing commonly made of EPDM (ethylene-propylene-diene monomer). In the electrical industry, organic insulators with housings made of different kinds of rubber have been employed since more than 20 years in high voltage transmission lines. However, the mechanisms of deterioration of the rubber are still unclear. In fact the progressive deterioration can to produce the unexpected failure of the material. The wide range of mechanical and electrical properties achieved by the polymers cannot be obtained with other type of material. Organic insulators have the advantages of low density, easy handling and good resistance to vandalism. However, environmental agents can damage them. In fact, rain, dust deposition, corona effect and ultraviolet radiation, among others, deteriorate the quality of the polymeric housing employed as watersheds. In the present work we analyse the disentanglement of the crystalline phase in the EPDM by means of the application of an electro-rheological model, recently published. We have performed dynamical mechanical analysis in EPDM samples obtained from commercial insulators. Samples were checked under different doses of irradiation with a low neutron flux. Irradiated sample with the largest crystalline degree exhibits the smallest relaxation time. Cross-linking process developed during the irradiation would appear to have a small effect on the disentanglement of crystals, in contrast to the chain-scission process. (author)

  5. Design and construction of a 10B coated ion chamber for the measurement of a thermal neutron flux

    International Nuclear Information System (INIS)

    Vite T, M.

    1979-01-01

    A model of an ionization chamber cover with 10 B, for the measurement of thermal neutron flux is presented, the developed chamber is made of a cylindrical vessel in which interior exist 7 aluminium electrodes which by electrodeposition were covered with a coat of 10 B with a thickness of 0.68 mg/cm 2 . Once the chamber is filled with N 2 to a pressure of 1.33 atm., it was exposed to a flux of thermal neutrons at the order 10 4 n/cm 2 -seg obtaining an ionization current of 10 -11 amp. which can be easily distinguished from the leak current which order is of 10 -12 amp. The conventional electronics associated to the chamber allows to process the ionization current in pulse form. The relation of noise to signal is approximately of 8, for which the pulses can be differentiated from the electronic noise without any problem. (author)

  6. Verification of Monte Carlo calculations of the neutron flux in the carousel channels of the TRIGA Mark II reactor, Ljubljana

    International Nuclear Information System (INIS)

    Jacimovic, R.; Maucec, M.; Trkov, A.

    2002-01-01

    In this work experimental verification of Monte Carlo neutron flux calculations in the carousel facility (CF) of the 250 kW TRIGA Mark II reactor at the Jozef Stefan Institute is presented. Simulations were carried out using the Monte Carlo radiation-transport code, MCNP4B. The objective of the work was to model and verify experimentally the azimuthal variation of neutron flux in the CF for core No. 176, set up in April 2002. '1'9'8Au activities of Al-Au(0.1%) disks irradiated in 11 channels of the CF covering 180'0 around the perimeter of the core were measured. The comparison between MCNP calculation and measurement shows relatively good agreement and demonstrates the overall accuracy with which the detailed spectral characteristics can be predicted by calculations.(author)

  7. Production of a faithful realistic phantom to human head and thermal neutron flux measurement on the brain surface. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Uchiyama, Junzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Endo, Kiyoshi; Yamamoto, Tetsuya; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan)

    2002-12-01

    Thermal neutron flux is determined using the gold wires in current BNCT irradiation, so evaluation of arbitrary points after the irradiation is limited in the quantity of these detectors. In order to make up for the weakness, dose estimation of a patient is simulated by a computational dose calculation supporting system. In another way without computer simulation, a medical irradiation condition can be replicate experimentally using of realistic phantom which was produced from CT images by rapid prototyping technique. This phantom was irradiated at a same JRR-4 neutron beam as clinical irradiation condition of the patient and the thermal neutron distribution on the brain surface was measured in detail. This experimental evaluation technique using a realistic phantom is applicable to in vitro cell irradiation experiments for radiation biological effects as well as in-phantom experiments for dosimetry under the nearly medical irradiation condition of patient. (author)

  8. Production of a faithful realistic phantom to human head and thermal neutron flux measurement on the brain surface. Cooperative research

    CERN Document Server

    Yamamoto, K; Kishi, T; Kumada, H; Matsumura, A; Nose, T; Torii, Y; Uchiyama, J; Yamamoto, T

    2002-01-01

    Thermal neutron flux is determined using the gold wires in current BNCT irradiation, so evaluation of arbitrary points after the irradiation is limited in the quantity of these detectors. In order to make up for the weakness, dose estimation of a patient is simulated by a computational dose calculation supporting system. In another way without computer simulation, a medical irradiation condition can be replicate experimentally using of realistic phantom which was produced from CT images by rapid prototyping technique. This phantom was irradiated at a same JRR-4 neutron beam as clinical irradiation condition of the patient and the thermal neutron distribution on the brain surface was measured in detail. This experimental evaluation technique using a realistic phantom is applicable to in vitro cell irradiation experiments for radiation biological effects as well as in-phantom experiments for dosimetry under the nearly medical irradiation condition of patient.

  9. EURISOL-DS Multi-MWatt Hg Target: Neutron flux and fission rate calculations for the MAFF configuration

    CERN Document Server

    Romanets, Y; Vaz, P; Herrera-Martinez, A; Kadi, Y; Kharoua, C; Lettry, J; Lindroos, M

    The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims at producing high intensity radioactive ion beams produced by neutron induced fission on a fissile target (235U) surrounding a liquid mercury converter. A proton beam of 1 GeV and 4 MW impinges on the Hg converter generating by spallation reactions high neutron fluxes. In this work the state-of-the-art Monte Carlo codes MCNPX and FLUKA were used to assess the neutronics performance of the system which geometry, inspired from the MAFF concept, allows a versatile manipulation of the fission targets. The objective of the study was to optimize the geometry of the system and the materials used in the fuel and reflector elements of the system, in order to achieve the highest possible fission rate.

  10. Survey of the thermal and fast neutron flux distribution in the core of IPR-R1 reactor

    International Nuclear Information System (INIS)

    Guimaraes, R.R.R.

    1985-01-01

    A methodology to obtain the neutron flux distribution inside the core of a reactor is presented, aiming to analyze specifications for increasing reactor power. The activation measurement technique with irradiation of steel eletrodes of 700 mm of lenght, put in acrylic rods was used. In the detection process and in the counting of activation product, a Ge (Li) detector with high resolution and a scanning mechanical system, constructed and projected in CDTN (Nuclear Technology Development Center) were used. (E.G.) [pt

  11. Measurement of the thermal and fast neutron flux in a research reactor with a Li and Th loaded optical fibre detector

    CERN Document Server

    Yamane, Y; Misawa, T; Karlsson, J K H; Pázsit, I

    1999-01-01

    The spatial dependence of thermal and fast neutron flux was measured axially in the core of a 1 MW research reactor. The measurements were made by a thin optical fibre detector with a neutron sensitive ZnS(Ag) scintillation tip. For thermal neutrons sup 6 Li was used, whereas for fast neutrons sup 2 sup 3 sup 2 Th was used as neutron converter. The spatial dependence was measured by moving the fibre axially with a uniform speed. The measurement takes a few minutes, compared to up to 10 h with the conventional wire activation method. Comparison with traditional measurements shows a good agreement. (author)

  12. Numerical effects in the neutron flux calculations into WWER-type reactor vessels by Monte Carlo method

    International Nuclear Information System (INIS)

    Alvarez Cardona, C.M.; Rodriguez Gual, M.; Hernandez Valle, S.

    2001-01-01

    The calculation of neutron fluxes and fluence into reactor pressure vessel is a regulatory requirement in the stages of the design, operation and plan lifetime extension. The reactor vessel is considered a unique and non-substitutable part of the NPP that undergoes degradation. The main source of the aging comes from the fast neutron damage induced in the steel crystalline lattice. Due to the proximity of the core edge to the vessel inner surface; the vessel steel is exposed to high fast neutron fluence. The effect of this irradiation on the mechanical properties becomes more acute because of the impurities measured in the Russian steel alloys. In the present paper, a PC version of the Monte Carlo 3-D HEXANN-EVALU system is used for the estimation of the WWER reactor pressure vessel irradiation. It was selected on the basis of its flexible options that on the other hand need to be quantified in connection with the desired magnitudes. The parameters that control the random walk of neutrons as well as the efficiency increasing options included in the code are studied in order to identify their impact in the final results for fluxes and fluence in the reactor pressure vessel. As a result an optimal set of parameters is suggested. (authors)

  13. Characterization of the neutron flux in the Hohlraum of the thermal column of the TRIGA Mark III reactor of the ININ

    International Nuclear Information System (INIS)

    Delfin L, A.; Palacios, J.C.; Alonso, G.

    2006-01-01

    Knowing the magnitude of the neutron flux in the reactor irradiation facilities, is so much importance for the operation of the same one, like for the investigation developing. Particularly, knowing with certain precision the spectrum and the neutron flux in the different positions of irradiation of a reactor, it is essential for the evaluation of the results obtained for a certain irradiation experiment. The TRIGA Mark III reactor account with irradiation facilities designed to carry out experimentation, where the reactor is used like an intense neutron source and gamma radiation, what allows to make irradiations of samples or equipment in radiation fields with components and diverse levels in the different facilities, one of these irradiation facilities is the Thermal Column where the Hohlraum is. In this work it was carried out a characterization of the neutron flux inside the 'Hohlraum' of the irradiation facility Thermal Column of the TRIGA Mark III reactor of the Nuclear Center of Mexico to 1 MW of power. It was determined the sub cadmic neutron flux and the epi cadmic by means of the neutron activation technique of thin sheets of gold. The maps of the distribution of the neutron flux for both energy groups in three different positions inside the 'Hohlraum' are presented, these maps were obtained by means of the irradiation of undressed thin activation sheets of gold and covered with cadmium in arrangements of 10 x 12, located parallel to 11.5 cm, 40.5 cm and 70.5 cm to the internal wall of graphite of the installation in inverse address to the position of the reactor core. Starting from the obtained values of neutron flux it was found that, for the same position of the surface of irradiation of the experimental arrangement, the relative differences among the values of neutron flux can be of 80%, and that the differences among different positions of the irradiation surfaces can vary until in a one order of magnitude. (Author)

  14. Enrichment of57Fe isotope in neutron flux of nuclear reactors observed by Mössbauer spectroscopy.

    Science.gov (United States)

    Sawicki, Jerzy A

    2018-02-01

    The abundance of 57 Fe isotope in nuclear reactor core materials can be considerably enriched by neutron-capture 56 Fe(n,γ) reactions. This is demonstrated using the sections of Zr-2.5 wt.%Nb pressure tubes removed from two CANDU* reactors. The tubes contained 0.11 and 0.04wt% Fe and were irradiated for about 10 effective full power years (EFPY) up to ~10 26 n/m 2 fast neutron (E > 1MeV) fluencies. The Mössbauer spectra of 57 Fe in irradiated samples indicated up to 10 times larger areas than unirradiated off-cuts from the same pressure tubes. The observed effect is in accord with the values calculated for known thermal neutron-capture cross-sections and resonance capture integrals, neutron flux profiles and spectra, and times of irradiation. The build-up of 57 Fe facilitated recording Mössbauer absorption spectra of alloys with minor amount of Fe down to ~ 400ppm, despite intense background radiation emitted by samples. These findings can open new possibilities in post-irradiation studies of alloys used in nuclear reactors and in other objects subjected to large neutron fluencies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Experimental and MCNP5 based evaluation of neutron and gamma flux in the irradiation ports of the University of Utah research reactor

    Directory of Open Access Journals (Sweden)

    Noble Brooklyn

    2012-01-01

    Full Text Available Neutron and gamma flux environment of various irradiation ports in the University of Utah training, research, isotope production, general atomics reactor were experimentally assessed and fully modeled using the MCNP5 code. The experimental measurements were based on the cadmium ratio in the irradiation ports of the reactor, flux profiling using nickel wire, and gamma dose measurements using thermo luminescence dosimeter. Full 3-D MCNP5 reactor model was developed to obtain the neutron flux distributions of the entire reactor core and to compare it with the measured flux focusing at the irradiation ports. Integration of all these analysis provided the updated comprehensive neutron-gamma flux maps of the existing irradiation facilities of the University of Utah TRIGA reactor.

  16. Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez

    Czech Academy of Sciences Publication Activity Database

    Kubešová, Marie; Kučera, Jan

    2012-01-01

    Roč. 293, č. 2 (2012), s. 665-674 ISSN 0236-5731 R&D Projects: GA ČR GA202/09/0363 Institutional support: RVO:61389005 Keywords : Neutron activation analysis * K(0) standardization * Neutron flux parameters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.467, year: 2012

  17. VSOP, Neutron Spectra, 2-D Flux Synthesis, Fuel Management, Thermohydraulics Calculation

    International Nuclear Information System (INIS)

    Teuchert, E.; Haas, K.A.

    1995-01-01

    1 - Description of problem or function: VSOP (Very Superior Old Programs) is a system of codes linked together for the simulation of reactor life histories. It comprises neutron cross section libraries and processing routines, repeated neutron spectrum evaluation, 2-D and 3-D diffusion calculation, depletion and shut-down features, in- core and out-of-pile fuel management, fuel cycle cost analysis, and thermal hydraulics (steady state and transient). Various techniques have been employed to accelerate the iterative processes and to optimize the internal data transfer. The code system has been used extensively for comparison studies of thermal reactors, their fuel cycles, thermal transients, and safety assessment. Besides its use in research and development work for the Gas Cooled High Temperature Reactor, the system has been applied successfully to Light Water and Heavy Water Reactors, MAGNOX, and RBMK. 2 - Method of solution: The nuclear data for 184 isotopes are contained in two libraries. Fast and epithermal data in a 68 group GAM-I structure have been prepared mainly from ENDF/B-V and JEF-1. Resonance cross section data are given as input. Thermal data in a 30 group THERMOS structure have been collapsed from a 96 group THERMALIZATION (GATHER) library by a relevant neutron energy spectrum generated by the THERMALIZATION code. Graphite scattering matrices are based on the Young phonon spectrum in graphite. The neutron spectrum is calculated by a combination of the GAM and THERMOS codes. They can simultaneously be employed for many core regions differing in temperature, burnup, and fuel element lay-out. The thermal cell code THERMOS has been extended to treat the grain structure of the coated particles inside the fuel elements, and the epithermal GAM code uses modified cross sections for the resonance absorbers prepared from double heterogeneous ZUT-DGL calculations. The diffusion module of the code is CITATION with 2 - 8 energy groups. It provides the neutron

  18. CUP-A New High-Flux Irradiation Position at the ANITA Neutron Facility at TSL

    Czech Academy of Sciences Publication Activity Database

    Prokofiev, A. V.; Passoth, E.; Hjalmarsson, A.; Majerle, Mitja

    2014-01-01

    Roč. 61, č. 4 (2014), s. 1929-1936 ISSN 0018-9499. [European Conference on Radiation and its Effects on Components and Systems (RADECS). Oxford, 23.09.2013-27.09.2013] Institutional support: RVO:61389005 Keywords : accelerated testing * integrated circuit radiation effects * neutron beams * neutron detectors * neutron radiation effects * radiation facilities * single event effects * soft error rates * terrestrial radiation environments * test facilities Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.283, year: 2014

  19. Measurement system of gamma, X, thermal and/or fast neutron flux

    International Nuclear Information System (INIS)

    Siffert, P.; Regal, R.; Koebel, J.M.; Teissier, C.

    1987-01-01

    The system includes detection means of gamma or/and X radiation, detection means of gamma and/or X radiation from thermal neutrons, detection means of gamma and/or X radiation from thermal and/or fast neutrons. It includes also processing devices of the signals given by the detection means able to get a linear combination of the detected signals. These processing devices give a signal selectively representative of photon, thermal or fast neutron rate [fr

  20. A monitor for neutron flux measurements up to 20 MeV.

    Science.gov (United States)

    Ohrn, A; Blomgren, J; Park, H; Khurana, S; Nolte, R; Schmidt, D; Wilhelmsen, K

    2007-01-01

    A liquid scintillation detector aimed for neutron energy and fluence measurements in the energy region neutron fields. Careful measurements of the proton light output function and the response matrix have been performed allowing for the application of unfolding techniques using existing codes. The response matrix is used to characterise monoenergetic neutron fields produced by the T(d,n) at a low-energy deuteron accelerator installed at the Swedish Defense Research Agency (FOI).

  1. Small angle neutron scattering study of the magnetic flux-line lattice in single crystal 2H-NbSe2

    DEFF Research Database (Denmark)

    Gammel, P.L.; Huse, D.A.; Kleiman, R.N.

    1994-01-01

    We report on a small angle neutron scattering study of the flux-line lattice in single crystal 2H-NbSe2. As the magnetic field is tilted away from the crystalline c axis, we find distortions in the flux lattice as would be expected for a mass anisotropy GAMMA = 10.1 +/- 0.9. However, we find...

  2. Use of Neutron Probe to Quantify the Soil Moisture Flux in Layers of Cultivated Soil by Chickpea

    International Nuclear Information System (INIS)

    El- Gendy, R.W.

    2008-01-01

    This work aims to use the neutron moisture meter and the soil moisture retention curve to quantify the soil moisture flux in the soil profile of Nubarria soil in Egypt at 15, 30, 45, and 60-cm depths during the growth season of Chickpea. This method depends on the use of in situ θ measurements via neutron moisture meter and soil matric suction using model of the soil moisture retention curve at different soil depths, which can be determined in situ. Total hydraulic potential values at the different soil depths were calculated as a function (θ) using the derivative model. The gradient of hydraulic potential at any soil depth can be obtained by detecting of the hydraulic potential within the soil profile. The soil water fluxes at the different soil depths were calculated using In situ measured unsaturated hydraulic conductivity and the gradient of hydraulic potential, which correlated with soil moisture contents as measured by neutron probe. Values of hydraulic potentials after and before irrigation indicate that the direction of soil moisture movement was downward after irrigation and was different before next irrigation. Collecting active roots for water absorption of chickpea were defined from direction of soil water movement from up and down to a certain soil depth was 19 cm depth from the soil surface. Active rooting depth was 53 cm depth, which separates between evapotranspiration and gravity effects The soil water fluxes after and before the next irrigation of chickpea were 1.2453, 0.8613, 0.8197 and 0.6588 cm/hr and 0.0037, - 0.0270,- 0.1341, and 0.2545 cm/hr at 15, 30, 45 and 60 cm depths, respectively. The negative values at 30 and 45 cm depth before the next irrigation indicates there were up ward movement for soil water flux, where finding collecting active roots for water absorption of chickpea at 19 cm depth. Direction of soil water movement, soil water flux, collecting active roots for water absorption and active rooting depth can be determined using

  3. Axial and radial distribution of neutron fluxes in the irradiation channels of the Ghana Research Reactor-1 using foil activation analysis and Monte Carlo

    International Nuclear Information System (INIS)

    Abrefah, G.R.

    2009-02-01

    The Monte-Carlo method and experimental methods were used to determine the neutron fluxes in the irradiation channels of the Ghana Research Reactor -1. The MCNP5 code was used for this purpose to simulate the radial and axial distribution of the neutron fluxes within all the ten irradiation channels. The results obtained were compared with the experimental results. After the MCNP simulation and experimental procedure, it was observed that axially, the fluxes rise to a peak before falling and then finally leveling out. Axially and radially, it was also observed that the fluxes in the centre of the channels were lower than on the sides. Radially, the fluxes dip in the centre while it increases steadily towards the sides of the channels. The results have shown that there are flux variations within the irradiation channels both axially and radially. (au)

  4. Neutron flux uncertainty and covariances for spectrum adjustment and estimation of WWER-1000 pressure vessel fluences

    International Nuclear Information System (INIS)

    Boehmer, Bertram

    2000-01-01

    Results of estimation of the covariance matrix of the neutron spectrum in the WWER-1000 reactor cavity and pressure vessel positions are presented. Two-dimensional calculations with the discrete ordinates transport code DORT in r-theta and r-z-geometry used to determine the neutron group spectrum covariances including gross-correlations between interesting positions. The new Russian ABBN-93 data set and CONSYST code used to supply all transport calculations with group neutron data. All possible sources of uncertainties namely caused by the neutron gross sections, fission sources, geometrical dimensions and material densities considered, whereas the uncertainty of the calculation method was considered negligible in view of the available precision of Monte Carlo simulation used for more precise evaluation of the neutron fluence. (Authors)

  5. Automated absolute activation analysis with californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg /sup 252/Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from /sup 17/O. Detection sensitivities of < or = 400 ppB for natural uranium and 8 ppB (< or = 0.5 (nCi/g)) for /sup 239/Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level.

  6. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  7. Thermal neutron diffusion parameters dependent on the flux energy distribution in finite hydrogenous media

    International Nuclear Information System (INIS)

    Drozdowicz, K.

    1999-01-01

    Macroscopic parameters for a description of the thermal neutron transport in finite volumes are considered. A very good correspondence between the theoretical and experimental parameters of hydrogenous media is attained. Thermal neutrons in the medium possess an energy distribution, which is dependent on the size (characterized by the geometric buckling) and on the neutron transport properties of the medium. In a hydrogenous material the thermal neutron transport is dominated by the scattering cross section which is strongly dependent on energy. A monoenergetic treatment of the thermal neutron group (admissible for other materials) leads in this case to a discrepancy between theoretical and experimental results. In the present paper the theoretical definitions of the pulsed thermal neutron parameters (the absorption rate, the diffusion coefficient, and the diffusion cooling coefficient) are based on Nelkin's analysis of the decay of a neutron pulse. Problems of the experimental determination of these parameters for a hydrogenous medium are discussed. A theoretical calculation of the pulsed parameters requires knowledge of the scattering kernel. For thermal neutrons it is individual for each hydrogenous material because neutron scattering on hydrogen nuclei bound in a molecule is affected by the molecular dynamics (characterized with internal energy modes which are comparable to the incident neutron energy). Granada's synthetic model for slow-neutron scattering is used. The complete up-dated formalism of calculation of the energy transfer scattering kernel after this model is presented in the paper. An influence of some minor variants within the model on the calculated differential and integral neutron parameters is shown. The theoretical energy-dependent scattering cross section (of Plexiglas) is compared to experimental results. A particular attention is paid to the calculation of the diffusion cooling coefficient. A solution of an equation, which determines the

  8. Enhancement of flux pinning properties in nanosized MgO added Bi-2212 superconductor through neutron irradiation

    Science.gov (United States)

    Mohiju, Zaahidah'Atiqah; Hamid, Nasri A.; Abdullah, Yusof

    2017-01-01

    For superconducting material to maintain high critical current density, Jc in any applications, effective flux pinning centers are needed. The addition of small size MgO particles in bulk Bi2Sr2CaCu2O8 (Bi-2212) superconductor has been proven to enhance the effective flux pinning centers in the superconducting material by creating a desired microstructure with appropriate defects. To further enhance the pinning properties, radiation is one of the convenient ways to improve the microstructure of the material that has correlation with basic properties of superconductors. Neutron irradiation is one of the niche techniques that can be used to perform the task. Defects with larger radius have dimension comparable to the coherence length of the material and thus improved its superconducting properties. In this paper, a small amount of nanosized MgO particles was used to create defects in the Bi-2212 superconducting material. The Bi-2212/MgO compounds were heat treated, followed by partial melting and slow cooling. Part of the samples was subjected to neutron irradiation using the TRIGA-MARK-II research reactor at the Malaysian Nuclear Agency. Characterization of non-irradiated and irradiated samples was performed via the temperature dependence on electrical resistance measurements, X-ray Diffraction Patterns (XRD), and Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray (EDX) analysis. From the analysis, there was changed in the critical current density and transition temperature of samples subjected to neutron irradiation due to formation of point defects in the microstructure. Higher critical current density indicates better flux pinning properties in the Bi-2212/MgO compounds.

  9. Neutrons in biology

    International Nuclear Information System (INIS)

    Funahashi, Satoru; Niimura, Nobuo.

    1993-01-01

    The start of JRR-3M in 1990 was a great epoch to the neutron scattering research in Japan. Abundant neutron beam generated by the JRR-3M made it possible to widen the research field of neutron scattering in Japan. In the early days of neutron scattering, biological materials were too difficult object to be studied by neutrons not only because of their complexity but also because of the strong incoherent scattering by hydrogen. However, the remarkable development of the recent neutron scattering and its related sciences, as well as the availability of higher flux, has made the biological materials one of the most attractive subjects to be studied by neutrons. In early September 1992, an intensive workshop titled 'Neutrons in Biology' was held in Hitachi City by making use of the opportunity of the 4th International Conference on Biophysics and Synchrotron Radiation (BSR92) held in Tsukuba. The workshop was organized by volunteers who are eager to develop the researches in this field in Japan. Numbers of outstanding neutron scattering biologists from U.S., Europe and Asian countries met together and enthusiastic discussions were held all day long. The editors believe that the presentations at the workshop were so invaluable that it is absolutely adequate to put them on record as an issue of JAERI-M and to make them available for scientists to refer to in order to further promote the research in the future. (author)

  10. Computation of higher spherical harmonics moments of the angular flux for neutron transport problems in spherical geometry

    International Nuclear Information System (INIS)

    Sahni, D.C.; Sharma, A.

    2000-01-01

    The integral form of one-speed, spherically symmetric neutron transport equation with isotropic scattering is considered. Two standard problems are solved using normal mode expansion technique. The expansion coefficients are obtained by solving their singular integral equations. It is shown that these expansion coefficients provide a representation of all spherical harmonics moments of the angular flux as a superposition of Bessel functions. It is seen that large errors occur in the computation of higher moments unless we take certain precautions. The reasons for this phenomenon are explained. They throw some light on the failure of spherical harmonics method in treating spherical geometry problems as observed by Aronsson

  11. A one-dimensional, one-group absorption-production nodal method for neutron flux and power distributions calculations

    International Nuclear Information System (INIS)

    Ferreira, C.R.

    1984-01-01

    It is presented the absorption-production nodal method for steady and dynamical calculations in one-dimension and one group energy. It was elaborated the NOD1D computer code (in FORTRAN-IV language). Calculations of neutron flux and power distributions, burnup, effective multiplication factors and critical boron concentration were made with the NOD1D code and compared with results obtained through the CITATION code, which uses the finite difference method. The nuclear constants were produced by the LEOPARD code. (M.C.K.) [pt

  12. Numerical effects in the neutron flux calculations into WWER-type reactor vessels using the Monte Carlo

    International Nuclear Information System (INIS)

    Garcia Yip, F.; Alvarez Cardona, C.M.; Rodriguez Gual, M.; Hernandez Valle, S.

    2000-01-01

    In the present paper, a PC version of the Monte Carlo 3-D HEXANN-EVALU system is used for the estimation of the WWER reactor pressure vessel irradiation. It was selected on the basis of its flexible options that, however, need to be quantified in connection with the desired magnitudes. The parameters that control the random walk of neutrons, as well as the efficiency increasing options included in the code, are studied in order to identify their impact on the final results for fluxes and fluence in the reactor pressure vessel. As a result, an optimal set of parameters is suggested. (authors)

  13. Flux

    DEFF Research Database (Denmark)

    Ravn, Ib

    . FLUX betegner en flyden eller strømmen, dvs. dynamik. Forstår man livet som proces og udvikling i stedet for som ting og mekanik, får man et andet billede af det gode liv end det, som den velkendte vestlige mekanicisme lægger op til. Dynamisk forstået indebærer det gode liv den bedst mulige...... kanalisering af den flux eller energi, der strømmer igennem os og giver sig til kende i vore daglige aktiviteter. Skal vores tanker, handlinger, arbejde, samvær og politiske liv organiseres efter stramme og faste regelsæt, uden slinger i valsen? Eller skal de tværtimod forløbe ganske uhindret af regler og bånd...

  14. Neutron scattering in applied research: possibilities for medium-flux research reactors

    International Nuclear Information System (INIS)

    Reijonen, H.

    1977-01-01

    The possibilities for neutron scattering techniques in applied research are reviewed. The areas covered are magnetism, determination of hydrogen self-diffusion constants and ionic mobility in superionic conductors, liquid crystals, molecular solids, polymers, surface chemistry and catalysts, colloids biology, physical metallurgy and neutron diagnostics. Established applications and new proposals for research projects are presented in various degrees of detail. Small angle scattering techniques, physical metallurgy and biology were identified as having particular potential. Prospective users should be realistically informed of the possibilities of neutron scattering techniques. (author)

  15. Neutron slowing down and transport in an infinite medium: 2, The scalar flux at large distances/small lethargies

    International Nuclear Information System (INIS)

    Cacuci, D.G.

    1987-01-01

    A companion paper has presented a Generalized Age-Theory expression for the scalar flux PSI 0 /sup G/(x,u) due to a plane isotropic source emitting neutrons in an infinite medium with cross sections that are constant in energy. The range of validity for this Generalized Age-Theory expression has also been determined as p = x/(2u) ≤ R(A), where R(A), the range of validity, is a function of the scatterer's mass. The purpose of this paper is to present the expression for the scalar flux Psi 0 /sup G/(x,u) in the complementary region in phase-space, i.e., where p > R(A)

  16. Evaluation of neutron flux in Al-Au alloy of different dimensions in the TRIGA IPR-R1 reactor using Monte Carlos Method

    International Nuclear Information System (INIS)

    Salome, Jean Anderson Dias

    2012-01-01

    Neutron Activation Analysis technique is applied in several procedures determining chemical elements - range of trace to percentage - in many materials; in radiochemical processes; archaeological and geological studies, in nuclear medicine and biochemical analysis and in forensic cases. It consists in submit a sample to a neutron flux and measure the induced activity by gamma spectrometry. Although it is a very useful method, the technique presents a limitation related to sample dimensions. The technique is applied in samples with micrograms to milligrams, or a few microliters to milliliters, when the density is negligible. In this work, using the Monte Carlo MCNP5 code, the effects of irradiated samples of different dimensions were simulated in the reactor TRIGA IPR-R1 of CDTN/CNEN, evaluating the total and thermal neutron fluxes. The values were compared to experimental values of thermal neutron flux determined for 11 most representative irradiation channels in the rotary rack. Statistical tests were used to evaluate the MCNP models. The results pointed out that a sample with 0.43 cm high, 0.48 cm radius and 1100 g.L -1 density, can be analyzed as it were a punctual sample, like soil sample, without disturbance of thermal neutron in the sample. For the total neutron flux, it can be concluded the same. Besides, 97% of the results are inside 95% confidence interval related to experimental values, as well as, 97% of the results are satisfactory for z-score. It points out the good performance of the modeling. (author)

  17. A base to standardize data processing of cadmium ratio RCd and thermal neutron flux measurements on reactor

    International Nuclear Information System (INIS)

    Li Zhaohuan

    1993-08-01

    The cadmium ratio R Cd and thermal neutron flux are usually measured in a reactor. But its data process is rather complex. The results from same measured data differ by different existing process methods. The purpose of this work is to standardize data processing in R Cd and thermal neutron flux measurements. A natural choice for this purpose is to derive a R Cd formula based on standard average thermal activation cross section and resonance integral and to define related parameters or factors that provide an unique base for comparison between different measurements in laboratories. The parameters or factors include E c , F m , F m ' and G th ' in thermal energy region due to upper truncated Maxwellian distribution and E Cd , F Cd , G r and S r in intermediate energy region. They are the function of multiple variables. The Au foil is used as an example to demonstrate their behaviors by chosen figures and tables which provide for practical data process by hand. The work also discusses limitation of R Cd measurement in terms of so called available and optimum region and notes that Co and Mn foils have a much wider available region among Au, In, Mn, W and Co, the commonly used detector foils

  18. The energy dependence of the cosmic-ray neutron leakage flux in the range 0.01-10 MeV.

    Science.gov (United States)

    Jenkins, R. W.; Ifedili, S. O.; Lockwood, J. A.; Razdan, H.

    1971-01-01

    Measurement of the cosmic-ray neutron leakage flux and energy spectrum in the range 1 to 10 MeV by a neutron detector on the Ogo 6 satellite from June 7 to Sept. 30, 1969. The same detector simultaneously measured the total leakage flux, having 75% of its response to the leakage flux in the interval from 1 keV to 1 MeV. For a neutron energy spectrum of the form AE to the minus gamma in the range from 1 to 10 MeV, the upper limit to gamma for polar regions was found to be 1.0 and for the equatorial regions was 1.2. For the polar regions, the lower limit to gamma was found to be 0.8. This energy spectrum at 1 to 10 MeV is slightly flatter than Newkirk (1963) predicted.

  19. The CG-1D Neutron Imaging Beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

    Science.gov (United States)

    Santodonato, Lou; Bilheux, Hassina; Bailey, Barton; Bilheux, Jean; Nguyen, Phong; Tremsin, Anton; Selby, Doug; Walker, Lakeisha

    The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better ;smoothing; of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 μSv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ∼ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 μs timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

  20. Neutronics Conversion Analyses of the Laue-Langevin Institute (ILL) High Flux Reactor (RHF)

    Energy Technology Data Exchange (ETDEWEB)

    Bergeron, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States); Calzavara, Y. [Inst. Laue-Langevin (ILL), Grenoble (France)

    2014-09-30

    The following report describes the neutronics results obtained with the MCNP model of the RHF U7Mo LEU reference design that has been established in 2010 during the feasibility analysis. This work constitutes a complete and detailed neutronics analysis of that LEU design using models that have been significantly improved since 2010 and the release of the feasibility report. When possible, the credibility of the neutronics model is tested by comparing the HEU model results with experimental data or other codes calculations results. The results obtained with the LEU model are systematically compared to the HEU model. The changes applied to the neutronics model lead to better comparisons with experimental data or improved the calculation efficiency but do not challenge the conclusion of the feasibility analysis. If the U7Mo fuel is commercially available, not cost prohibitive, a back-end solution is established and if it is possible to manufacture the proposed element, neutronics analyses show that the performance of the reactor would not be challenged by the conversion to LEU fuel.

  1. Comparison of neutron fluxes in an 18-MeV unshielded cyclotron room and a 16.5-MeV self-shielded cyclotron room.

    Science.gov (United States)

    Fujibuchi, Toshioh; Horitsugi, Genki; Yamaguchi, Ichiro; Eto, Akihisa; Iwamoto, Yasuo; Obara, Satoshi; Iimori, Takashi; Masuda, Yoshitada; Watanabe, Hiroshi; Hatazawa, Jun

    2012-07-01

    Some medical compact cyclotrons have self-shielding to reduce neutron fluxes. Thermal neutron fluxes in an 18-MeV unshielded cyclotron room and in a 16.5-MeV self-shielded cyclotron room were evaluated. In addition, the radioactivities in concrete and metals due to thermal neutrons in the cyclotron rooms for 30 years were calculated of operation such that the sum of the ratio of the nuclide concentration to the nuclide clearance level was equal to 1. The thermal neutron flux from the unshielded cyclotron was approximately 10(2) cm(-2) s(-1), whereas that from the self-shielded cyclotron was approximately 10(2) cm(-2) s(-1). The thermal neutron fluxes for concrete, stainless steel, vessel steel, and aluminum that reached their clearance levels were 9.80 × 10(4), 2.17 × 10(3), 1.87 × 10(4), and 2.41 × 10(5) cm(-2) s(-1), respectively. The specific activities in the cyclotron room were found to be sufficiently below the clearance level when the self-shield was employed.

  2. Photoneutrons from a beryllium reflector: a potential source of problems with Zr-Au flux monitors ink0standardization based neutron activation analysis.

    Science.gov (United States)

    Koster-Ammerlaan, M J J; Bode, P; Winkelman, A J M

    The assumption that the shape of the epithermal neutron spectrum can be described, in any research reactor, by the 1/ E 1+α function is a fundamental starting point of the k 0 standardization. This assumption may be questioned from a reactor physics viewpoint. The type of moderator, the existence of neutron reflectors, the additional production of (γ, n ) neutrons and resonance capture by construction materials may be different for each reactor, with consequences for the shape of the neutron spectrum. This dependency may explain that various practitioners reported contradicting experiences with the use of Zr-Au flux monitors for the determination of the α-parameter. An objective view on the influence of the design of the reactor and irradiation facility on the shape of the neutron spectrum can be obtained by modeling. This has been applied in the Reactor Institute Delft for reactor configurations in which the irradiation facilities face the fuel elements with the presence of beryllium reflector elements. The Monte Carlo calculations indicate a distortion of the 1/ E 1+α relationship at the higher energy edge of the epithermal neutron spectrum. This distortion is attributed to the formation and thermalisation of both photoneutrons and ( n , 2 n ) produced fast neutrons in the beryllium, and has a direct impact on the resonance activation of 95 Zr, other than represented by the 1/ E 1+α function. The obtained relationship between neutron flux and neutron energy was also used for estimating the f -value and compared with the value obtained by the Delft Cr-Mo-Au flux monitor.

  3. Neutron flux determination at the horizontal beam tubes of the Rossendorf research reactor RFR

    International Nuclear Information System (INIS)

    Stephan, I.; Schneider, B.; Boehmer, B.; Boehme, K.; Mehner, H.C.

    1992-01-01

    To characterize the irradiation possibilities of the RFR, in particular the values concerning the steel tubes, diffusion- and transport-theoretical calculations have been made and supported by experiments. The measurements also served to provide secured data for the experts on the ad hoc committee ''Rossendorf Research Reactor'' to assess the neutron situation of German research reactors. (orig.) [de

  4. Neutron activation of patients following boron neutron capture therapy of brain tumors at the high flux reactor (HFR) Petten (EORTC Trials 11961 and 11011).

    Science.gov (United States)

    Wittig, Andrea; Moss, Raymond L; Stecher-Rasmussen, Finn; Appelman, Klaas; Rassow, Jürgen; Roca, Antoanetta; Sauerwein, Wolfgang

    2005-12-01

    At the High Flux Reactor (HFR), Petten, The Netherlands, EORTC clinical trials of Boron Neutron Capture Therapy (BNCT) have been in progress since 1997. BNCT involves the irradiation of cancer patients by a beam of neutrons, with an energy range of predominantly 1 eV to 10 keV. The patient is infused with a tumor-seeking, (10)B-loaded compound prior to irradiation. Neutron capture in the (10)B atoms results in a high local radiation dose to the tumor cells, whilst sparing the healthy tissue. Neutron capture, however, also occurs in other atoms naturally present in tissue, sometimes resulting in radionuclides that will be present after treatment. The patient is therefore, following BNCT, radioactive. The importance of this induced activity with respect to the absorbed dose in the patient as well as to the radiation exposure of the staff has been investigated. As a standard radiation protection procedure, the ambient dose equivalent rate was measured on all patients following BNCT using a dose ratemeter. Furthermore, some of the patients underwent measurements using a gamma-ray spectrometer to identify which elements and confirm which isotopes are activated. Peak levels, i.e., at contact and directly after irradiation, are of the order of 40-60 muSv/h, falling to < 10 muSv/h 30-50 min after treatment. The average ambient dose equivalent in the first 2 h at a distance of 2 m from the patient is in the order of 2.5 muSv. The ambient dose equivalent rate in 2 m distance from the patient's head at the earliest time of leaving the reactor center (20 min after the end of treatment) is far less than 1 muSv/h. The main radioisotopes were identified as (38)Cl, (49)Ca, and (24)Na. Furthermore, in two patients, the isotopes (198)Au and (116m)In were also present. The initial activity is predominantly due to (49)Ca, whilst the remaining activity is predominantly due to (24)Na. The absorbed dose resulting from the activated isotopes in the irradiated volume is in the order of < 1

  5. The flat flux problem in one-speed neutron transport theory

    International Nuclear Information System (INIS)

    Williams, M.M.R.

    2003-01-01

    The classic flat flux problem in nuclear reactor physics, first solved by Goertzel using diffusion theory, is extended to one-speed transport theory. A numerical solution is obtained for a general two region problem in which the inner region has a flat flux and the outer one a spatially variable flux. For the exact solution, plane geometry is employed with the optical path representation. This solution allows the accuracy of a more flexible but approximate method to be assessed. A feature of the problem which has not been noted before is that in the region of flat flux the current is not zero. The reason for this is explained and is used to assess the accuracy of the approximation method. Diffusion theory is shown to be a poor but not unreasonable approximation. However, to make it viable it is necessary to introduce generalised function solutions to the diffusion equation. The theory is illustrated in detail by numerical calculations. It is shown that a flat flux in one speed theory corresponds to a maximum fuel loading. This is in contrast to the multigroup case for which it is a minimum loading

  6. THERMAL NEUTRON FLUX MAPPING ON A TARGET CAPSULE AT RABBIT FACILITY OF RSG-GAS REACTOR FOR USE IN k0-INAA

    Directory of Open Access Journals (Sweden)

    Sutisna Sutisna

    2015-03-01

    Full Text Available Instrumental neutron activation analysis based on the k0 method (k0-INAA requires the availability of the accurate reactor parameter data, in particular a thermal neutron flux that interact with a targets inside the target capsule. This research aims to determine and map the thermal neutron flux inside the capsule and irradiation channels used for the elemental quantification using the k0-AANI. Mapping of the thermal neutron flux (фth on two type of irradiation capsule have been done for RS01 and RS02 facilities of RSG-GAS reactor. Thermal neutron flux determined using Al-0,1%Au alloy through 197Au(n,g 198Au nuclear reaction, while the flux mapping done using statistics R. Thermal neutron flux are calculated using k0-IAEA software provided by IAEA. The results showed the average thermal neutron flux is (5.6±0.3×10+13 n.cm-2.s-1; (5.6±0.4×10+13 n.cm-2.s-1; (5.2±0.4×10+13 n.cm-2.s-1 and (5.3±0.4×10+13 n.cm-2.s-1 for Polyethylene capsule of 1st , 2nd, 3rd and 4th layer respectively. In the case of Aluminum capsule, the thermal neutron flux was lower compared to that on Polyethylene capsule. There were (3.0±0.2×10+13 n.cm-2.s-1; (2.8±0.1×10+13 n.cm-2.s-1; (3.2±0.3×10+13 n.cm-2.s-1 for 1st, 2nd and 3rd layers respectively. For each layer in the capsule, the thermal neutron flux is not uniform and it was no degradation flux in the axial direction, both for polyethylene and aluminum capsules. Contour map of eight layer on polyethylene capsule and six layers on aluminum capsule for RS01 and RS02 irradiation channels had a similar pattern with a small diversity for all type of the irradiation capsule. Keywords: thermal neutron, flux, capsule, NAA   Analisis aktivasi neutron instrumental berbasis metode k0 (k0-AANI memerlukan ketersediaan data parameter reaktor yang akurat, khususnya data fluks neutron termal yang berinteraksi dengan inti sasaran di dalam kapsul target. Penelitian ini bertujuan menentukan dan memetakan fluks neutron termal

  7. An Interpretation of the Neutron Scattering Data on Flux Lattices of Superconductors

    OpenAIRE

    Chang, D.; Mou, C. -Y.; Rosenstein, B.; Wu, C. L.

    1997-01-01

    Small angle neutron diffraction experiments are analyzed using recently developed and properly generalized one-field effective free energy method. In the case of experiment of Keimer et al on YBCO, we show that the fourfold symmetry of the underlying crystal is explicitly broken, but the reflection with respect to the [110] and [1\\={1}0] axes remains a symmetry. The vortex lattice also becomes generally oblique instead of rectangular body centered. Unexpectedly rich phase diagram is described.

  8. Analysis of neutron flux depression across the pellet radius in CANDU fuel elements

    International Nuclear Information System (INIS)

    Sim, K.S.; Suk, H.C.

    1998-08-01

    The TUBRNP model, originally developed to perform the analysis of the flux depression across the pellet radius in LWR fuel elements, was improved for the application to CANDU fuel elements. The improved model was verified through comparison with existing CANDU model named FLUXDEP in prediction for various fuel conditions. A sensitivity study was also performed to investigate the effects on the flux depression of fuel initial enrichment and burnup, the contents of isotopes U-234 and U-236 and pellet diameter. (author). 9 refs., 8 figs

  9. Xenon poisoning method for the determination of the average thermal neutron flux, macroscopic fission and total absorption cross sections

    International Nuclear Information System (INIS)

    Durmayaz, A.; Sisman, A.; Cetin Sisman, F.; Yavuz, H.

    1997-01-01

    The paper presents the xenon poisoning method as an experimental way to determine the average thermal neutron flux (anti φ), the average macroscopic fission cross section (anti Σ f ) and the average total macroscopic absorption cross section (anti Σ a ) together with the reactivity change due to the 135 Xe poisoning. The predictions for the reactivity change due to the 135 Xe poisoning are in good agreement with the results of the experiments. The results of anti φ, anti Σ f and anti Σ a obtained by using the xenon poisoning method are also in satisfactorily agreement with the predictions of TRIGAP and WIMS-D/4 computer codes. The temperature coefficients of the reactivity for the fuel and tank water have also been determined experimentally during this study. (orig.) [de

  10. Reactivity and neutron flux measurements in IPEN/MB-01 reactor with B4C burnable poison

    International Nuclear Information System (INIS)

    Fer, Nelson Custodio; Moreira, Joao Manoel Losada

    2000-01-01

    Burnable poison rods, made of B 4 C- Al 2 O 3 pellets with 5.01 mg/cm 3 10 B concentration, have been manufactured for a set of experiments in the IPEN/MB-01 zero-power reactor. Several core parameters which are affected by the burnable poisons rods have been measured. The principal results, for the situation in which the burnable poison rods are located near the absorber rods of a control rod, are they cause a 29% rod worth shadowing, a reduction of 39% in the local void coefficient of reactivity, a reduction of 4.8% in the isothermal temperature coefficient of reactivity, and a reduction of 9% in the thermal neutron flux in the region where the burnable poison rods are located. These experimental results will be used for the validation of burnable poison calculation methods in the CTMSP. (author)

  11. Complementary system for monitoring and control of neutron flux during a fuel outage and during reactor start up stage

    International Nuclear Information System (INIS)

    Lichkov, R.

    2000-01-01

    The present work is an example for that, how with modern technical instruments is possible to compensate disadvantage and to increase technical resources of the old systems, without a change of given system totally with new one. The system detail design and implementation was possible mostly, due to the international conferences and courses organised by IAEA and technical information provided by the agency. The designed system plays a role of complementary system to the in-situ operational systems for monitoring and control of the reactor core neutron flux, allowing its measurement and control during a fuel outage and during reactor start up stage. Additionally, the system recalculates the reactivity in beta units and according to its value the reactor criticality fixed up reactivity is defined. (author)

  12. Design and construction of an automatic measurement electronic system and graphical neutron flux for the subcritical reactor

    International Nuclear Information System (INIS)

    Gonzalez M, J.L.; Balderas, E.G.; Rivero G, T.

    1997-01-01

    The National Institute of Nuclear Research (ININ) has in its installations with a nuclear subcritical reactor which was designed and constructed with the main purpose to be used in the nuclear sciences education in the Physics areas and Reactors engineering. Within the nuclear experiments that can be realized in this reactor are very interesting those about determinations of neutron and gamma fluxes spectra, since starting from these some interesting nuclear parameters can be obtained. In order to carry out this type of experiments different radioactive sources are used which exceed the permissible doses by far to human beings. Therefore it is necessary the remote handling as of the source as of detectors used in different experiments. In this work it is presented the design of an electronic system which allows the different positions inside of the tank of subcritical reactor at ININ over the radial and axial axes in manual or automatic ways. (Author)

  13. Calibration of the nuclear power channels for the cylindrical configuration of the IPEN/MB-01 reactor obtained from the measurements of the spatial neutron flux distribution in the reactor core through the irradiation of gold foils

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Silva, Alexandre F. Povoa da; Mura, Luiz Ernesto Credidio; Aredes, Vitor Ottoni Garcia; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br, E-mail: alexpovoa@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The activation foil is one of the most used techniques to obtain and compare nuclear parameters from the nuclear data libraries, given by a gamma spectrometry system. Through the measurements of activity induced in the foils, it is possible to determine the neutron flux profile exactly where it has been irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. The objective of this work is to obtain, for a cylindrical configuration, the power generation through a spatial thermal neutron flux distribution in the core of IPEN/MB-01 Reactor, by irradiating gold foils positioned symmetrically into the core. They are put in a Lucite plate which will not interfere in the analysis of the neutron flux, because of its low microscopic absorption cross section for the analyzed neutrons. The foils are irradiated with and without cadmium covered small plates, to obtain the thermal and epithermal neutron flux, through specific equations. The correlation between the average power neutron flux, as a result of the foil's irradiation, and the average power digital neutron flux of the nuclear power channels, allows the calibration of the nuclear channels of the reactor. This same correlation was done in 2008 with the reactor in a rectangular configuration, which resulted in a specific calibration of the power level operation. This calibration cannot be used in the cylindrical configuration, because the nuclear parameters could change, which may lead to a different neutron profile. Furthermore, the precise knowledge of the power neutron flux in the core also validates the mathematics used to calculate the power neutron flux. (author)

  14. Structural stability of the square flux line lattice in YNi2B2C and LuNi2B2C studied with small angle neutron scattering

    DEFF Research Database (Denmark)

    Eskildsen, M.R.; Gammel, P.L.; Barber, B.P.

    1997-01-01

    We have studied the flux line lattice in YNi2B2C and LuNi2B2C, the nonmagnetic end members of the borocarbide superconductors using small angle neutron scattering and transport. For fields, H parallel to c, we find a square symmetric lattice which disorders rapidly above H/H-c2 similar to 0.2, well...

  15. Experimental study of angular neutron flux spectra on a slab surface to assess nuclear data and calculational methods for a fusion reactor design

    International Nuclear Information System (INIS)

    Oyama, Yukio

    1988-06-01

    This paper presents an experimental approach to interpret the results of integral experiments for fusion neutronics research. The measurement is described of the angular neutron flux on a restricted area of slab assemblies with D-T neutron bombardment by using the time-of-flight (TOF) method with an NE213 neutron detector over an energy range from 0.05 to 15 MeV. A two bias scheme was developed to obtain an accurate detection efficiency over a wide energy range. The detector-collimator response function was introduced to define the restricted surface area and to determine the effective measured area. A series of measurements of the angular neutron flux on slabs of fusion blanket materials, i.e., Be, C, and Li 2 O, as functions of neutron leaking angle and slab thickness have been performed to examine neutron transport characteristics in bulk materials. The calculational analyses of the experimental results have been also carried out by using Monte Carlo neutron transport codes, i.e., MORSE-DD and MCNP. The existing nuclear data files, i.e., JENDL-3PR1, -3PR2, ENDF/B-IV and -V were tested by comparing with the experimental results. From the comparisons, the data on C and 7 Li in the present files are fairly sufficient. Those on beryllium, however, is insufficient for the estimation of high threshold reactions such as tritium production in a fusion reactor blanket design. It is also found that the total and elastic cross sections are more important for accurate predictions of neutronic parameters at deep position. The comparisons between the measured and calculated results provide information to understand the results of the previous integral experiments for confirmation of accuracy of fusion reactor designs. (author)

  16. Study of the effect of the energy spectrum and of the total flux on the damage produced by neutrons in solids

    International Nuclear Information System (INIS)

    Dulieu, P.C.

    1967-01-01

    In the first part are studied the general relationships between the physical effects produced by neutrons in solids, and the total flux and neutron energy spectrum; some examples are given. The second part, describes the application to a silicon damage detector whose principle is to use the damage produced in a PIN Junction for measuring the neutron flux (intermediate and fast) received by the detector. Chapter I is devoted to the experimental determination of the energy given to the atoms by a primary in the silicon. The results and conclusions drawn from this determination make it possible to consider, in chapter II, the calculation of the detectors response characteristics.Chapter III deals with the measurement of the detectors response function and it is noted that good agreement is obtained between the calculation and experimental results. The whole of the second part constitutes a test of the methods presented in the first part. (author) [fr

  17. Study of neutronic flux in IPR-R1 reactor with MCNPX; Estudo do fluxo neutronico no reator IPR-R1 com o MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Melo, J.A.S.; Castrillo, L.S., E-mail: julio.angelo@poli.br, E-mail: lazara@poli.br [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica; Oliveira, R.M.B.M., E-mail: romero.matias@educacao.pe.gov.br [Secretaria Executiva de Educacao do Estado de Pernambuco (SEE), Recife, PE (Brazil)

    2016-11-01

    MCNPX computer code, one of the latest versions of code MCNP transport were used to study the flux distribution and its neutronic fluence as a function of energy in two research reactor irradiation IPR-R1. The model developed was validated with research conducted by Dalle (2005). Initially, in the simulation is considered fresh fuel whose core configuration contained three neutron rods control, being two of them 100% ejected while the other inserted 3,1 x 10{sup -1} m deep, as adopted in the literature situation. The neutron source used was the critical type, through KSRC card. The results of the neutron flow and neutronic fluence were obtained in the central tube and the turntable on a range of energy spectrum that ranged from 1.0 x 10{sup -9} MeV to 10 MeV, showing good correlations with the model used in validation. Finally, a hypothetical situation wherein the three reactor control rods are ejected simultaneously was simulated. The simulation results showed an increase in the neutron flux of 7% in the central tube and 5% on the turntable.

  18. Epithermal neutron flux distribution and its impact on (n, γ) activation analysis result

    International Nuclear Information System (INIS)

    Jovanovich, S.; Pukotich, P.; Zejnilovich, R.; Corte, F. de; Moens, L.; Hoste, J.; Simonitis, A.

    1985-01-01

    The differences are discussed between the simplified model, introduced to derive the generally accepted ideal 1/E - law, and the conditions existing in an actual reactor. For absolute and comparator types of (n, γ) activation analysis (NAA), the semiempirical 1/Esup(1+α) form is a better approximation - necessary to introduce, but sufficient for practical purposes. Parameter α, being a measure of the epithermal nonideality, is a characteristics of the reactor site. The impact of this nonideality on NAA result is outlined, together with the method for appropriate correction

  19. Last Improvements of the CALMOS Calorimeter Dedicated to Thermal Neutron Flux and Nuclear Heating Measurements inside the OSIRIS Reactor

    Science.gov (United States)

    Carcreff, H.; Salmon, L.; Lepeltier, V.; Guyot, J. M.; Bouard, E.

    2018-01-01

    Nuclear heating inside an MTR reactor needs to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. To improve the nuclear heating knowledge, an innovative calorimetric system CALMOS has been studied, manufactured and tested for the 70MWth OSIRIS reactor operated by CEA. This device is based on a mobile calorimetric probe which can be inserted in any in-core experimental location and can be moved axially from the bottom of the core to 1000 mm above the core mid-plane. Obtained results and advantages brought by the first CALMOS-1 equipment have been already presented. However, some difficulties appeared with this first version. A thermal limitation in cells did not allow to monitor nuclear heating up to the 70 MW nominal power, and some significant discrepancies were observed at high heating rates between results deduced from the calibration and those obtained by the "zero method". Taking this feedback into account, the new CALMOS-2 calorimeter has been designed both for extending the heating range up to 13W.g-1 and for improving the "zero method" measurement thanks to the implementation of a 4-wires technique. In addition, the new calorimeter has been designed as a real operational measurement system, well suited to characterize and to follow the radiation field evolution throughout the reactor cycle. To meet this requirement, a programmable system associated with a specific software allows automatic complete cell mobility in the core, the data acquisition and the measurements processing. This paper presents the analysis of results collected during the 2015 comprehensive measurement campaign. The 4-wires technique was tested up to around a 4 W.g-1 heating level and allowed to quantify discrepancies between "zero" and calibration methods. Thermal neutron flux and nuclear heating measurements from CALMOS-1 and CALMOS-2 are compared. Thermal neutron flux distributions, obtained with the Self-Power Neutron

  20. Last Improvements of the CALMOS Calorimeter Dedicated to Thermal Neutron Flux and Nuclear Heating Measurements inside the OSIRIS Reactor

    Directory of Open Access Journals (Sweden)

    Carcreff H.

    2018-01-01

    Full Text Available Nuclear heating inside an MTR reactor needs to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. To improve the nuclear heating knowledge, an innovative calorimetric system CALMOS has been studied, manufactured and tested for the 70MWth OSIRIS reactor operated by CEA. This device is based on a mobile calorimetric probe which can be inserted in any in-core experimental location and can be moved axially from the bottom of the core to 1000 mm above the core mid-plane. Obtained results and advantages brought by the first CALMOS-1 equipment have been already presented. However, some difficulties appeared with this first version. A thermal limitation in cells did not allow to monitor nuclear heating up to the 70 MW nominal power, and some significant discrepancies were observed at high heating rates between results deduced from the calibration and those obtained by the “zero method”. Taking this feedback into account, the new CALMOS-2 calorimeter has been designed both for extending the heating range up to 13W.g-1 and for improving the “zero method” measurement thanks to the implementation of a 4-wires technique. In addition, the new calorimeter has been designed as a real operational measurement system, well suited to characterize and to follow the radiation field evolution throughout the reactor cycle. To meet this requirement, a programmable system associated with a specific software allows automatic complete cell mobility in the core, the data acquisition and the measurements processing. This paper presents the analysis of results collected during the 2015 comprehensive measurement campaign. The 4-wires technique was tested up to around a 4 W.g-1 heating level and allowed to quantify discrepancies between “zero” and calibration methods. Thermal neutron flux and nuclear heating measurements from CALMOS-1 and CALMOS-2 are compared. Thermal neutron flux distributions

  1. Neutron and gamma characterization within the FFTF reactor cavity

    International Nuclear Information System (INIS)

    Bunch, W.L.; Carter, L.L.; Moore, F.S.; Werner, E.J.; Wilcox, A.D.; Wood, M.R.

    1980-08-01

    Neutron and gamma ray measurements were made within the reactor cavity of the Fast Flux Test Facility (FFTF) to establish the operating characteristics of the Ex-Vessel Flux Monitoring (EVFM) system as a function of reactor power level. A significant effort was made to obtain absolute flux values in order that the measurements could be compared directly with shield design calculations. Good agreement was achieved for neutrons and for both the prompt and delayed components of the gamma ray field. 8 figures, 3 tables

  2. Production Potential of 47Sc Using Spallation Neutron Flux at the Los Alamos Isotope Production Facility

    Science.gov (United States)

    2014-03-27

    up, and high-fidelity delayed-gamma emission. MCNP6 is a fusion of MCNPX and MCNP5. MCNP5 allows for neutral particle and electron transport, while...bins will be listed [20]. This tally, in combination with the eighth entry on MCNPs LCA physics model card entry, NOACT, is very useful in extracting...19 and 23 (K, Ca, Sc, Ti, and V) resulting from direct neutron reactions. The 8th LCA entry of NOACT=-2 forces the model to assume all particles react

  3. The new digital neutron flux measuring system in Wuergassen nuclear power plant

    International Nuclear Information System (INIS)

    Pilhofer, K.H.

    1994-01-01

    The 670 MW boiling water reactor of Wuergassen Nuclear Power Plant became critical for the first time on October 22, 1971. A very important criterion for all components is the reliability. With the dew digital neutron flow-measuring system TK250, the development of the failure rate is very positive. On the occasion of the 1993 revision, the existing 12 electronic cubicles were replaced by 4 new ones. Within only three weeks, all connections to the detectors, to the safety system, the control room, the signal system and the process calculator have been made. (orig.) [de

  4. Results of a neutron flux perturbation experiment with Babcock and Wilcox Owners Group surveillance capsules

    International Nuclear Information System (INIS)

    Snidow, N.L.; Hassler, L.A.

    1989-01-01

    The Babcock and Wilcox Owners Group (B and WOG) Flux Perturbation Experiment in the Oak Ridge National Laboratory Poolside Facility simulated the thermal shield, downcomer, pressure vessel, and cavity region of a B and W-designed 177-fuel assembly reactor by an arrangement of steel slabs and a void box. Two simulated surveillance capsules located in the downcomer were irradiated as part of the NRC-sponsored Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Pregram. The capsules contained extensive dosimetry provided B and W and the Hanford Engineering Development Laboratory (HEDL). Dosimeters were also located outside of the capsules in the downcomer region. Flux distributions were calculated throughout the test configuration using the two-dimensional DOT 4.3 transport theory code. The calculated and measured data are compared in this paper

  5. Determination of neutron flux distribution by using ANISN, a one-dimensional discrete S sub n ordinates transport code with anisotropic scattering

    Science.gov (United States)

    Ghorai, S. K.

    1983-01-01

    The purpose of this project was to use a one-dimensional discrete coordinates transport code called ANISN in order to determine the energy-angle-spatial distribution of neutrons in a 6-feet cube rock box which houses a D-T neutron generator at its center. The project was two-fold. The first phase of the project involved adaptation of the ANISN code written for an IBM 360/75/91 computer to the UNIVAC system at JSC. The second phase of the project was to use the code with proper geometry, source function and rock material composition in order to determine the neutron flux distribution around the rock box when a 14.1 MeV neutron generator placed at its center is activated.

  6. Absolute determination of neutron detection efficiencies of NE213 detectors using a sup 2 sup 5 sup 2 Cf source in time-of-flight measurements

    CERN Document Server

    Schmidt, D

    2001-01-01

    Neutron detection efficiencies of NE213 scintillation detectors were determined by comparison of the measured neutron time-of-flight spectrum of a sup 2 sup 5 sup 2 Cf source deposited in a parallel-plate, low-mass ionization chamber with its reference neutron energy distribution. Measurement conditions and parameters were systematically varied to study their influence on the efficiencies obtained. The efficiencies derived from the measurement were compared with well-established efficiencies of the detectors used. These efficiencies were calculated with a Monte Carlo code and corrected after comparison with a proton recoil telescope in neutron fluence measurements. Details of the measurement and the data analysis including the corrections needed are discussed.

  7. HERITAGE: the concept of a giant flux neutron reflectometer for the exploration of 3-d structure of free-liquid and solid interfaces in thin films

    Energy Technology Data Exchange (ETDEWEB)

    Mattauch, S., E-mail: s.mattauch@fz-juelich.de [JCNS at MLZ, Forschungszentrum-Jülich GmbH, 85747 Garching (Germany); Ioffe, A. [JCNS at MLZ, Forschungszentrum-Jülich GmbH, 85747 Garching (Germany); Lott, D. [Helmholtz Zentrum Geesthacht, 21502 Geesthacht (Germany); Bottyán, L. [Wigner Research Center for Physics, 1525 Budapest (Hungary); Daillant, J. [Synchrotron Soleil L' Orme des Merisiers Saint-Aubin, BP 48 91192 Gif-sur-Yvette (France); Markó, M. [Wigner Research Center for Physics, 1525 Budapest (Hungary); Menelle, A. [Laboratoire Léon Brillouin CEA/CNRS, CEA Saclay, 91191 Gif sur Yvette (France); Sajti, S.; Veres, T. [Wigner Research Center for Physics, 1525 Budapest (Hungary)

    2017-01-01

    The instrumental concept of HERITAGE – a reflectometer with a horizontal sample geometry – well fitted to the long pulse structure of a neutron source is presented. It is constitutes a new class of reflectometers achieving the unprecedentedly high flux for classical specular reflectometry combined with off-specular reflectometry and grazing incidence small-angle scattering (GISANS), thus resulting in a complete 3-d exploration of lateral and in depth structures in thin films. This is achieved by specially designed neutron guides. In the horizontal direction (perpendicular to the scattering plane) the guide's elliptic shape focusses the neutrons onto the sample. In the vertical direction a multichannel geometry provides a smooth divergence distribution at the sample position while accepting the entire beam from a compact high-brilliance flat moderator. The modular collimation setup of HERITAGE provides extremely high flexibility in respect to sample geometries and environments, including the possibility to study virtually all types of solid and liquid interfaces, statically or kinetically. The use of multiple beam illumination allows for reflectivity and GISANS measurements at liquid interfaces both from above and below without a need to move the sample. This concept assures the delivery of the maximum possible and usable flux to the sample in both reflectivity and GISANS measurement regimes. The presented design outperforms the flux of all present-day and already for the ESS planned reflectometers and GISANS setups in flux and in measuring time for standard samples.

  8. Atmospheric neutrons

    International Nuclear Information System (INIS)

    Preszler, A.M.; Moon, S.; White, R.S.

    1976-01-01

    Additional calibrations of the University of California double-scatter neutron and additional analysis corrections lead to the slightly changed neutron fluxes reported here. The theoretical angular distributions of Merker (1975) are in general agreement with our experimental fluxes but do not give the peaks for vertical upward and downward moving neutrons. The theoretical neutron escape current J 2 /sub pi/ (Merker, 1972; Armstrong et al., 1973) is in agreement with the experimental values from 10 to 100 MeV. Our experimental fluxes agree with those of the Kanbach et al. (1974) in the overlap region from 70 to 100 MeV

  9. Calibration issues for neutron diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sadler, G.J. [JET Joint Undertaking, Abingdon (United Kingdom); Adams, J.M. [AEA Technology, Harwell (United Kingdom); Barnes, C.W. [Los Alamos National Lab., NM (United States)] [and others

    1997-12-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next.

  10. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  11. Determination of nitrogen in wheat flour through Activation analysis using Fast neutron flux of a Thermal nuclear reactor; Determinacion de nitrogeno en harina de trigo mediante analisis por activacion empleando el flujo de neutrones rapidos de un reactor nuclear termico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez G, T

    1976-07-01

    In this work is done a technical study for determining Nitrogen (protein) and other elements in wheat flour Activation analysis, with Fast neutrons from a Thermal nuclear reactor. Initially it is given an introduction about the basic principles of the methods of analysis. Equipment used in Activation analysis and a brief description of the neutron source (Thermal nuclear reactor). The realized experiments for determining the flux form in the irradiation site, the half life of N-13 and the interferences due to the sample composition are included too. Finally, the obtained results by Activation and the Kjeldahl method are tabulated. (Author)

  12. Consequences of the embrittlement of channels following neutron irradiation in a High Flux Reactor

    International Nuclear Information System (INIS)

    Bauer, E.

    1987-01-01

    Channel failure is an incident that the reactor design takes into account and whose consequences have been studied and accepted during the safety analysis of the facilities. The study of the failure modes (Chapter 3) has shown that the embrittlement of the material due to neutron irradiation does not constitute a fact that could fundamentally change the probability of failure compared to a new reactor. The mechanical properties of the irradiated material in elastic regime are not below the values of the new material. In this respect, the second part of the AG3 NET - HFR test program, whose results are available, does not raise concerns, given the very high mechanical properties of the irradiated material. Consequently, no preventive provisions have to be made, since the irradiated material is compatible with its use as structural material for the channels. The study of the failure modes also demonstrated that mechanical blows applied to irradiated material could lead to destruction because of the reduced plastic deformability. However, this risk only arises when the reactor is shut down during maintenance operations that require access to equipment placed inside the channels

  13. Experimental assessment of incineration rates of actinides in high intensity neutron fluxes

    International Nuclear Information System (INIS)

    Deruelle, O.

    2001-01-01

    The Mini-inca project develops new experimental facilities and computational methods to carry out integral measurements of actinide transmutation in given irradiation conditions. 2 types of irradiations are foreseen: -) short irradiations to have a precise determination of unknown nuclear parameters such as capture and fission cross sections including branching ratios; -) long irradiations of mono-isotopic sample or known mixtures of isotopes to determine transmutation rates in given high intensity neutron spectra. Irradiations will be carried out in the ILL reactor in Grenoble. A new detection system named Mini-inca chamber has been developed and installed at the ILL reactor, it allows accurate alpha-gamma spectroscopy just after irradiation and even between successive irradiations of the same sample. The advantages of alpha-gamma spectroscopy to determine the composition of the sample are that it is fast, it needs no chemistry and it is non-destructive. The first validation experiments have been performed and their results concerning the irradiation of a Pu-242 target are presented. (A.C.)

  14. Neutron source

    Science.gov (United States)

    Cason, J.L. Jr.; Shaw, C.B.

    1975-10-21

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap.

  15. Neutron source

    International Nuclear Information System (INIS)

    Cason, J.L. Jr.; Shaw, C.B.

    1975-01-01

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap

  16. T2K off-axis near detector νμ flux measurement and absolute momentum scale calibration of the off-axis near detector tracker

    International Nuclear Information System (INIS)

    Blaszczyk, F.

    2011-09-01

    In this thesis we present the results from the ν μ energy spectrum measurement at T2K's near detector and T2K's near detector tracker absolute momentum scale calibration. First we review the main historical steps and the current state of the art of neutrino physics as well as the theoretical framework required to understand the thesis physics analyses presented later on. In particular we focus on the neutrino oscillation parametrization and the neutrino-matter interaction models. We then describe T2K, an off-axis long baseline neutrino oscillation experiment in Japan which consists of a muon neutrino beam sent from J-PARC to Super- Kamiokande, with a magnetized near detector located at 280 m from the neutrino production site. T2K's main goals are measuring the last unknown angle of the PMNS matrix θ 13 through the search of ν e appearance in the ν μ beam and measuring precisely the atmospheric parameters through muon neutrino disappearance. We briefly describe the detectors, in particular the near detector tracker and its performance. We then present the analyses tools, such as the reconstruction techniques used and how the neutrino charged current interaction events needed for the energy spectrum measurement are selected. The main goal of the thesis, the muon neutrino energy spectrum measurement done with the first T2K data is explained next. We give the motivations for such measurement, the results obtained with the first T2K data sample, and the different systematic errors studied. Finally, the absolute momentum scale calibration of T2K's near detector tractor, done through the reconstruction of the neutral kaon invariant mass, is explained. (author)

  17. Concept for Inclusion of Analytical and Computational Capability in Optical Plume Anomaly Detection (OPAD) for Measurement of Neutron Flux

    Science.gov (United States)

    Patrick, Marshall Clint; Cooper, Anita E.; Powers, W. T.

    2004-01-01

    Researchers are working on many fronts to make possible high-speed, automated classification and quantification of constituent materials in numerous environments. NASA's Marshall Space Flight Center has implemented a system for rocket engine flowfields/plumes. The Optical Plume Anomaly Detector (OPAD) system was designed to utilize emission and absorption spectroscopy for monitoring molecular and atomic particulates in gas plasma. An accompanying suite of tools and analytical package designed to utilize information collected by OPAD is known as the Engine Diagnostic Filtering System (EDiFiS). The current combination of these systems identifies atomic and molecular species and quantifies mass loss rates in H2/O2 rocket plumes. Capabilities for real-time processing are being advanced on several fronts, including an effort to hardware encode components of the EDiFiS for health monitoring and management. This paper addresses the OPAD with its tool suites, and discusses what is considered a natural progression: a concept for taking OPAD to the next logical level of high energy physics, incorporating fermion and boson particle analyses in measurement of neutron flux.

  18. On an analytical evaluation of the flux and dominant eigenvalue problem for the steady state multi-group multi-layer neutron diffusion equation

    International Nuclear Information System (INIS)

    Ceolin, Celina; Schramm, Marcelo; Bodmann, Bardo Ernst Josef; Vilhena, Marco Tullio Mena Barreto de

    2014-01-01

    In this work the authors solved the steady state neutron diffusion equation for a multi-layer slab assuming the multi-group energy model. The method to solve the equation system is based on an expansion in Taylor Series resulting in an analytical expression. The results obtained can be used as initial condition for neutron space kinetics problems. The neutron scalar flux was expanded in a power series, and the coefficients were found by using the ordinary differential equation and the boundary and interface conditions. The effective multiplication factor k was evaluated using the power method. We divided the domain into several slabs to guarantee the convergence with a low truncation order. We present the formalism together with some numerical simulations.

  19. On an analytical evaluation of the flux and dominant eigenvalue problem for the steady state multi-group multi-layer neutron diffusion equation

    Energy Technology Data Exchange (ETDEWEB)

    Ceolin, Celina; Schramm, Marcelo; Bodmann, Bardo Ernst Josef; Vilhena, Marco Tullio Mena Barreto de [Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica; Bogado Leite, Sergio de Queiroz [Comissao Nacional de Energia Nuclear, Rio de Janeiro (Brazil)

    2014-11-15

    In this work the authors solved the steady state neutron diffusion equation for a multi-layer slab assuming the multi-group energy model. The method to solve the equation system is based on an expansion in Taylor Series resulting in an analytical expression. The results obtained can be used as initial condition for neutron space kinetics problems. The neutron scalar flux was expanded in a power series, and the coefficients were found by using the ordinary differential equation and the boundary and interface conditions. The effective multiplication factor k was evaluated using the power method. We divided the domain into several slabs to guarantee the convergence with a low truncation order. We present the formalism together with some numerical simulations.

  20. Setup for polarized neutron imaging using in situ3He cells at the Oak Ridge National Laboratory High Flux Isotope Reactor CG-1D beamline.

    Science.gov (United States)

    Dhiman, I; Ziesche, Ralf; Wang, Tianhao; Bilheux, Hassina; Santodonato, Lou; Tong, X; Jiang, C Y; Manke, Ingo; Treimer, Wolfgang; Chatterji, Tapan; Kardjilov, Nikolay

    2017-09-01

    In the present study, we report a new setup for polarized neutron imaging at the ORNL High Flux Isotope Reactor CG-1D beamline using an in situ 3 He polarizer and analyzer. This development is very important for extending the capabilities of the imaging instrument at ORNL providing a polarized beam with a large field-of-view, which can be further used in combination with optical devices like Wolter optics, focusing guides, or other lenses for the development of microscope arrangement. Such a setup can be of advantage for the existing and future imaging beamlines at the pulsed neutron sources. The first proof-of-concept experiment is performed to study the ferromagnetic phase transition in the Fe 3 Pt sample. We also demonstrate that the polychromatic neutron beam in combination with in situ 3 He cells can be used as the initial step for the rapid measurement and qualitative analysis of radiographs.

  1. Setup for polarized neutron imaging using in situ 3He cells at the Oak Ridge National Laboratory High Flux Isotope Reactor CG-1D beamline

    Science.gov (United States)

    Dhiman, I.; Ziesche, Ralf; Wang, Tianhao; Bilheux, Hassina; Santodonato, Lou; Tong, X.; Jiang, C. Y.; Manke, Ingo; Treimer, Wolfgang; Chatterji, Tapan; Kardjilov, Nikolay

    2017-09-01

    In the present study, we report a new setup for polarized neutron imaging at the ORNL High Flux Isotope Reactor CG-1D beamline using an in situ 3He polarizer and analyzer. This development is very important for extending the capabilities of the imaging instrument at ORNL providing a polarized beam with a large field-of-view, which can be further used in combination with optical devices like Wolter optics, focusing guides, or other lenses for the development of microscope arrangement. Such a setup can be of advantage for the existing and future imaging beamlines at the pulsed neutron sources. The first proof-of-concept experiment is performed to study the ferromagnetic phase transition in the Fe3Pt sample. We also demonstrate that the polychromatic neutron beam in combination with in situ 3He cells can be used as the initial step for the rapid measurement and qualitative analysis of radiographs.

  2. Prospects for a new cold neutron beam measurement of the neutron lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Greene, Geoffrey L [ORNL; Snow, William M [ORNL; Dewey, M. [National Institute of Standards and Technology (NIST), Gaithersburg, MD; Gilliam, D [National Institute of Standards and Technology (NIST), Gaithersburg, MD; Nico, Jeffrey S [ORNL; Coakley, K [National Institute of Standards and Technology (NIST), Boulder; Yue, A [University of Tennessee, Knoxville (UTK); Laptev, A [Los Alamos National Laboratory (LANL); Wietfeldt, F [Tulane University

    2009-01-01

    In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

  3. Prospects for a new cold neutron beam measurement of the neutron lifetime

    Science.gov (United States)

    Dewey, M.; Coakley, K.; Gilliam, D.; Greene, G.; Laptev, A.; Nico, J.; Snow, W.; Wietfeldt, F.; Yue, A.

    2009-12-01

    In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

  4. Prospects for a new cold neutron beam measurement of the neutron lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, M., E-mail: mdewey@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Coakley, K., E-mail: kevin.coakley@nist.go [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Gilliam, D., E-mail: david.gilliam@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Greene, G., E-mail: greenegl@ornl.go [Department of Physics, University of Tennessee, Knoxville, TN 37996 (United States); Physics Division, Oak Ridge National Lab, Building 6010, Oak Ridge, TN 37831 (United States); Laptev, A., E-mail: alaptev@nist.go [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Nico, J., E-mail: jnico@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Snow, W., E-mail: wsnow@indiana.ed [Indiana University/IUCF, Bloomington, IN 47408 (United States); Wietfeldt, F., E-mail: few@tulane.ed [Tulane University, New Orleans, LA 70118 (United States); Yue, A., E-mail: ayue@nist.go [Department of Physics, University of Tennessee, Knoxville, TN 37996 (United States)

    2009-12-11

    In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

  5. Neutron flux depression in the UO2-PuO2 (15 to 30%) fuel rods from IVO-FR2-Vg7-Irradiation experiment

    International Nuclear Information System (INIS)

    Lopez Jimenez, J.; Fernandez Marron, J.L.

    1983-01-01

    The thermal-neutron flux depression within a fuel rod has a great influence on the radial temperature profile of the rod, especially for high enrichment fuel. For this reason, a study was made about the UO 2 -PuO 2 (15 to 30% PuO 2 ) fuel pins for the KfK-JEN joint irradiation program IVO, in the FR2 reactor. Different methods (diffusion, Bonalumi, successive generations) were compared and a new approach (parabolic approximation) was developed. (author)

  6. Neutron Flux Depression in the UO2-PuO2 (15 to 30%) Fuel Rods from IVO-FR2-Vg7-Irradiation Experiment

    International Nuclear Information System (INIS)

    Lopez Jimenez, J.; Fernandez Marron, J.L.

    1983-01-01

    The thermal-neutron flux depression within a fuel rod has a great influence in the radial temperature profile of the rod, especially for high enrichment fuel. For this reason, a study was made about the UO 2 -PUO 2 (15 to 30% PUO 2 ) fuel pins for the KfK-JEN joint irradiation program IVO, in the FR2 reactor. Different methods (diffusion, Bonalumi, successive generations) were compared and a new approach (parabolic approximation) was developed. (Author) 22 refs

  7. The influence of the number of activation detectors on the Seibersdorf - Milano intercomparison of neutron flux density spectra by WINDOWS code

    International Nuclear Information System (INIS)

    Ertek, C.

    1981-02-01

    This work is a continuation of the work performed within the IAEA programme on standardization of reactor radiation measurements, one of the important objectives of which is the assistance to laboratories in Member States to implement or intercompare the multiple foil activation techniques for different neutron field measurements. The importance of these techniques is well recognized. In CESNEF-FERMI Politecnico di Milano, Italy, they have installed near the core of a water boiler of 50kW, a neutron filter made of B 4 C in order to obtain a neutron flux density spectrum that could be of utility in intercalibration problems connected with irradiation in fast assemblies. Dr. V. Sangiust from CESNEF kindly sent the input guess neutron flux density spectrum and a series of measured reaction rates to be treated by the IAEA Seibersdorf laboratory using the SAND-II and the WINDOWS unfolding codes. The meaningful comparison using partly the same ENDF/B IV cross section data is performed. In the present work we extended the investiga tion using WINDOWS unfolding code for different numbers of activation fo ils or reaction rates

  8. Measure of thermal neutron flux in the IPEN/MB-01 reactor using {sup 197} Au wire activation detectors; Medida do fluxo de neutrons termicos do reator IPEN/MB-01 com detectores de ativacao de fios de {sup 197} Au

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Andre Luis Ferreira

    1995-12-31

    This dissertation has aimed at developing a neutron flux measurement technique by means of detectors activation analysis. The main task of this work was the implementation of this thermal neutron flux measurement technique, using gold wires as activation detectors in the IPEN/MB-01 reactor core. The neutron thermal flux spatial distribution was obtained by gold wire activation technique, with wire diameters of 0.125 mm and 0.250 mm in seven selected reactor experimental channels. The values of thermal flux were about 10{sup 9} neutrons/cm{sup 2}.s. This experiment has been the first one conducted with gold wires in the IPEN/MB-01 reactor, being this technique implemented for use by experiments in flux mapping of the core 73 refs., 60 figs., 31 tabs.

  9. Small angle neutron scattering on an absolute intensity scale and the internal surface of diatom frustules from three species of differing morphologies

    Czech Academy of Sciences Publication Activity Database

    Garvey, C. J.; Strobl, M.; Percot, A.; Šaroun, Jan; Haug, J.; Vyverman, W.; Chepurnov, V. A.; Ferris, J. M.

    2013-01-01

    Roč. 42, č. 5 (2013), s. 395-404 ISSN 0175-7571 Institutional support: RVO:61389005 Keywords : biosilica * diffusion limited aggregation * small angle neutron scattering * Raman spectroscopy * infrared spectroscopy * Porod law * BET isotherm * biomineralisation Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.474, year: 2013 http://link.springer.com/content/pdf/10.1007%2Fs00249-013-0889-x.pdf

  10. Measurement of the high-energy neutron flux on the surface of the natural uranium target assembly QUINTA irradiated by deuterons of 4- and 8-GeV energy

    International Nuclear Information System (INIS)

    Adam, J.; Baldin, A.A.; Chilap, V.

    2014-01-01

    Experiments with a natural uranium target assembly QUINTA exposed to 4- and 8 GeV deuteron beams of the Nuclotron accelerator at the Joint Institute for Nuclear Research (Dubna) are analyzed. The 129 I, 232 Th, 233 U, 235 U, nat U, 237 Np, 238 Pu, 239 Pu and 241 Am radioactive samples were installed on the surface of the QUINTA set-up and irradiated with secondary neutrons. The neutron flux through the RA samples was monitored by Al foils. The reaction rates of 27 Al(n, y 1 ) 24 Na, 27 Al(n, y 2 ) 22 Na and 27 Al(n, y 3 ) 7 Be reactions with the effective threshold energies of 5, 27 and 119 MeV were measured at both 4- and 8-GeV deuteron beam energies. The average neutron fluxes between the effective threshold energies and the effective ends of the neutron spectra (which are 800 or 1000 MeV for energy of 4- or 8-GeV deuterons) were determined. The evidence for the intensity shift of the neutron spectra to higher neutron energies with the increase of the deuteron energy from 4 to 8 GeV was found from the ratios of the average neutron fluxes. The reaction rates and the average neutron fluxes were calculated with MCNPX2.7 and MARS15 codes.

  11. Detection and elimination of the electromagnetic interferences in the neutron flux measurement circuit, Source Range; Deteccion y eliminacion de interferencias electromagneticas en el circuito de medicion de flujo neutronico, rango de fuente

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, J. M.; Esguivillas, L.; Valle, J. L.

    2010-07-01

    This paper compiles an experience in Asco I Nuclear Power Plant about electromagnetic interferences associated to the neutron flux measurement system, Source Range Asco I NPP. The circuit affected is the proportional detector (BF3) located outside the reactor vessel to measure the neutron leakage in shutdown and in start-up.

  12. Time-dependent flux from pulsed neutrons revealed by superconducting Nb current-biased kinetic inductance detector with 10B converter operated at 4 K

    International Nuclear Information System (INIS)

    Miyajima, Shigeyuki; Narukami, Yoshito; Shishido, Hiroaki; Yoshioka, Naohito; Ishida, Takekazu; Fujimaki, Akira; Hidaka, Mutsuo; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Arai, Masatoshi

    2015-01-01

    We have demonstrated a new superconducting detector for a neutron based on Nb superconductor meanderline with a 10 B conversion layer. We use a current-biased kinetic inductance detector (CB-KID), which is composed of a meanderline, for detection of a neutron with high spatial resolution and fast response. The thickness of Nb meanderlines is 40 nm and widths are 3 μm, 1 μm, and 0.6 μm. The CB-KIDs are fabricated at the center of the Si chip of the size 22 mm × 22 mm and the total area of CB-KIDs covers 8 mm × 8 mm. The chip was cooled to a temperature lower than 4 K below the transition temperature of Nb using a Gifford-McMahon (GM) cryocooler. The Nb CB-KIDs with a 10 B conversion layer output the voltage by irradiating pulsed neutrons at the material life science experimental facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC) center. The response time of CB-KIDs is about a few tens ns. We have also obtained the time dependence of neutron flux generated from pulsed neutrons using a CB-KID. Experimental results were in good agreement with the simulated results. (author)

  13. Development of a computer code for neutronic calculations of a hexagonal lattice of nuclear reactor using the flux expansion nodal method

    Directory of Open Access Journals (Sweden)

    Mohammadnia Meysam

    2013-01-01

    Full Text Available The flux expansion nodal method is a suitable method for considering nodalization effects in node corners. In this paper we used this method to solve the intra-nodal flux analytically. Then, a computer code, named MA.CODE, was developed using the C# programming language. The code is capable of reactor core calculations for hexagonal geometries in two energy groups and three dimensions. The MA.CODE imports two group constants from the WIMS code and calculates the effective multiplication factor, thermal and fast neutron flux in three dimensions, power density, reactivity, and the power peaking factor of each fuel assembly. Some of the code's merits are low calculation time and a user friendly interface. MA.CODE results showed good agreement with IAEA benchmarks, i. e. AER-FCM-101 and AER-FCM-001.

  14. Industrial production and purification of 32P by sulfur irradiation with partially moderated neutron fluxes and target melting

    International Nuclear Information System (INIS)

    Alanis, J.; Navarrete, M.

    2007-01-01

    Target purification of S α is carried out by distillation at 444±2 deg C under N atmosphere and diluting the vapors in CS 2 . The solution is filtered through fiberglass, Teflon and cellulose to obtain S α by CS 2 evaporation. Once 30 g of this target are irradiated with fast neutron fluxes from 4.5 to 7.4 x 10 12 n x cm -2 x s -1 from 6 to 12 hours, the nuclear reaction 32 S(n,p) 32 P takes place. So, the irradiated S α sample is placed in a Pyrex container situated inside a furnace as the most important piece of equipment in one aluminum and Lucite glove box. The distillation of irradiated sulfur takes place at 444±2 deg C under N atmosphere during 1-2 hours. The vapors are connected to a sulfur diluter containing 20% CS 2 aqueous solution, followed by an activated carbon filter and the two similar additional sulfur diluters. Once cooled, the distillation chamber keeps the radioactive, carrier-free 32 P stuck to the wall. Then 25-50 ml of 0.1N HCl acid was injected by suction and heated again at 110±2 deg C during 1 hour. The corresponding chemical reaction takes place and the labeled H 3 32 PO 4 solution is produced. In such a way, industrial production of 32 P labeled molecules has started in Mexico, with an initial production of 3700-5550 MBq per week. (author)

  15. Measurement of neutron captured cross-sections in 1-2 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gi Dong; Kim, Young Sek; Kim, Jun Kon; Yang, Tae Keun [Korea Institutes of Geoscience and Mineral Resources, Taejeon (Korea)

    2001-04-01

    The measurement of neutron captured reaction cross sections was performed to build the infra system for the production of nuclear data. MeV neutrons were produced with TiT target and {sup 3}T(p,n){sup 3}He reaction. The characteristics of TiT thin film was analyzed with ERD-TOF and RBS. The results was published at Journal of the Korea Physical Society (SCI registration). The energy, the energy spread and the flux of the produced neutron were measured. The neutron excitation functions of {sup 12}C and {sup 16}O were obtained to confirm the neutron energy and neutron energy spread. The neutron energy spread found to be 1.3 % at the neutron energy of 2.077 MeV. The {sup 197}Au(n,{gamma}) reaction was performed to obtain the nerutron flux. The maximum neutron flux found to be 1 x 10{sup 8} neutrons/sec at the neutron energy of 2 MeV. The absolute efficiency of liquid scintillation detector was obtained in the neutron energy of 1 - 2 MeV. The fast neutron total reaction cross sections of Cu, Fe, and Au were measured with sample in-out method. Also the neutron captured reaction cross sections of {sup 63}Cu were measured with fast neutron activation method. The measurement of neutron total reaction cross sections and the neutron captured reaction cross sections with fast neutrons were first tried in Korea. The beam pulsing system was investigated and the code of calculating the deposition spectrums for primary gamma rays was made to have little errors at nuclear data. 25 refs., 28 figs., 14 tabs. (Author)

  16. A semi-experimental nodal synthesis method for the on-line reconstruction of three-dimensional neutron flux-shapes and reactivity

    International Nuclear Information System (INIS)

    Jacqmin, R.P.

    1991-01-01

    The safety and optimal performance of large, commercial, light-water reactors require the knowledge at all time of the neutron-flux distribution in the core. In principle, this information can be obtained by solving the time-dependent neutron diffusion equations. However, this approach is complicated and very expensive. Sufficiently accurate, real-time calculations (time scale of approximately one second) are not yet possible on desktop computers, even with fast-running, nodal kinetics codes. A semi-experimental, nodal synthesis method which avoids the solution of the time-dependent, neutron diffusion equations is described. The essential idea of this method is to approximate instantaneous nodal group-fluxes by a linear combination of K, precomputed, three-dimensional, static expansion-functions. The time-dependent coefficients of the combination are found from the requirement that the reconstructed flux-distribution agree in a least-squares sense with the readings of J (≥K) fixed, prompt-responding neutron-detectors. Possible numerical difficulties with the least-squares solution of the ill-conditioned, J-by-K system of equations are brought under complete control by the use of a singular-value-decomposition technique. This procedure amounts to the rearrangement of the original, linear combination of K expansion functions into an equivalent more convenient, linear combination of R (≤K) orthogonalized ''modes'' of decreasing magnitude. Exceedingly small modes are zeroed to eliminate any risk of roundoff-error amplification, and to assure consistency with the limited accuracy of the data. Additional modes are zeroed when it is desirable to limit the sensitivity of the results to measurement noise

  17. A semi-experimental nodal synthesis method for the on-line reconstruction of three-dimensional neutron flux-shapes and reactivity. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Jacqmin, Robert P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    1991-12-10

    The safety and optimal performance of large, commercial, light-water reactors require the knowledge at all time of the neutron-flux distribution in the core. In principle, this information can be obtained by solving the time-dependent neutron diffusion equations. However, this approach is complicated and very expensive. Sufficiently accurate, real-time calculations (time scale of approximately one second) are not yet possible on desktop computers, even with fast-running, nodal kinetics codes. A semi-experimental, nodal synthesis method which avoids the solution of the time-dependent, neutron diffusion equations is described. The essential idea of this method is to approximate instantaneous nodal group-fluxes by a linear combination of K, precomputed, three-dimensional, static expansion-functions. The time-dependent coefficients of the combination are found from the requirement that the reconstructed flux-distribution agree in a least-squares sense with the readings of J (≥K) fixed, prompt-responding neutron-detectors. Possible numerical difficulties with the least-squares solution of the ill-conditioned, J-by-K system of equations are brought under complete control by the use of a singular-value-decomposition technique. This procedure amounts to the rearrangement of the original, linear combination of K expansion functions into an equivalent more convenient, linear combination of R (≤K) orthogonalized ``modes`` of decreasing magnitude. Exceedingly small modes are zeroed to eliminate any risk of roundoff-error amplification, and to assure consistency with the limited accuracy of the data. Additional modes are zeroed when it is desirable to limit the sensitivity of the results to measurement noise.

  18. A semi-experimental nodal synthesis method for the on-line reconstruction of three-dimensional neutron flux-shapes and reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Jacqmin, R.P.

    1991-12-10

    The safety and optimal performance of large, commercial, light-water reactors require the knowledge at all time of the neutron-flux distribution in the core. In principle, this information can be obtained by solving the time-dependent neutron diffusion equations. However, this approach is complicated and very expensive. Sufficiently accurate, real-time calculations (time scale of approximately one second) are not yet possible on desktop computers, even with fast-running, nodal kinetics codes. A semi-experimental, nodal synthesis method which avoids the solution of the time-dependent, neutron diffusion equations is described. The essential idea of this method is to approximate instantaneous nodal group-fluxes by a linear combination of K, precomputed, three-dimensional, static expansion-functions. The time-dependent coefficients of the combination are found from the requirement that the reconstructed flux-distribution agree in a least-squares sense with the readings of J ({ge}K) fixed, prompt-responding neutron-detectors. Possible numerical difficulties with the least-squares solution of the ill-conditioned, J-by-K system of equations are brought under complete control by the use of a singular-value-decomposition technique. This procedure amounts to the rearrangement of the original, linear combination of K expansion functions into an equivalent more convenient, linear combination of R ({le}K) orthogonalized modes'' of decreasing magnitude. Exceedingly small modes are zeroed to eliminate any risk of roundoff-error amplification, and to assure consistency with the limited accuracy of the data. Additional modes are zeroed when it is desirable to limit the sensitivity of the results to measurement noise.

  19. Fast neutron induced flux pinning in Tl-based high-Tc single crystals and thin films, highly textured tapes and melt-textured bulk 123-superconductors

    International Nuclear Information System (INIS)

    Brandstaetter, G.; Samadi Hosseinalli, G.; Kern, C.; Sauerzopf, F.M.; Schulz, G.W.; Straif, W.; Yang, X.; Weber, H.W.; Hu, Q.Y.

    1999-01-01

    Various compounds (TI-2223, TI-1223, TI-2212) as well as material forms (single crystals, thin films, ceramics, tapes) of TI-based high temperature superconductors were investigated by magnetic and transport techniques. TI-2223 has a very 'low lying' irreversibility line (H parallel e) and negligible critical current densities J c at 77 K. However, the irreversibility line shifts to higher fields and temperatures and J c is strongly enhanced, even at 77 K, after fast neutron irradiation. In contrast, the related TI-1223 compound has a much steeper irreversibility line (H parallel c) similar to that of Y-123. J c is significant up to 77 K, even in the unirradiated state, and can be largely improved by neutron irradiation. Transport measurements made on TI-1223 tapes still show much lower critical current densities. TI-2212 and Tl-2223 thin films have J c 's at 77 K, which are comparable to those of TI-1223 single crystals. Transport measurements on highly textured Bi-2223 tapes as well as flux profile measurements on Nd-123 bulk superconductors confirm the beneficial effects of neutron induced defects (collision cascades) for flux pinning. (author)

  20. Neutron monitors and muon detectors for solar modulation studies: Interstellar flux, yield function, and assessment of critical parameters in count rate calculations

    Science.gov (United States)

    Maurin, D.; Cheminet, A.; Derome, L.; Ghelfi, A.; Hubert, G.

    2015-01-01

    Particles count rates at given Earth location and altitude result from the convolution of (i) the interstellar (IS) cosmic-ray fluxes outside the solar cavity, (ii) the time-dependent modulation of IS into Top-of-Atmosphere (TOA) fluxes, (iii) the rigidity cut-off (or geomagnetic transmission function) and grammage at the counter location, (iv) the atmosphere response to incoming TOA cosmic rays (shower development), and (v) the counter response to the various particles/energies in the shower. Count rates from neutron monitors or muon counters are therefore a proxy to solar activity. In this paper, we review all ingredients, discuss how their uncertainties impact count rate calculations, and how they translate into variation/uncertainties on the level of solar modulation ϕ (in the simple Force-Field approximation). The main uncertainty for neutron monitors is related to the yield function. However, many other effects have a significant impact, at the 5-10% level on ϕ values. We find no clear ranking of the dominant effects, as some depend on the station position and/or the weather and/or the season. An abacus to translate any variation of count rates (for neutron and μ detectors) to a variation of the solar modulation ϕ is provided.

  1. Calculation of the neutron flux and fluence in the covering of the nucleus and the vessel of a BWR; Calculo del flujo neutronico y fluencia en la envolvente del nucleo y la vasija de un reactor nuclear BWR

    Energy Technology Data Exchange (ETDEWEB)

    Martinez C, E.; Del Valle G, E. [IPN, Escuela Superior de Fisica y Matematicas, U. P. Adolfo Lopez Mateos, Col. Lindavista, 07738 Mexico D. F. (Mexico); Longoria G, L. C., E-mail: evalle@esfm.ipn.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    One of the main objectives related with the safety in any nuclear power plant, including the nuclear power plant of Laguna Verde, is to guarantee the structural integrity of the pressure vessel of the reactor. To identify and quantifying the damage caused be neutron irradiation in the vessel of any nuclear reactor, is necessary to know as much the neutron flux as the fluence that it has been receiving during their time of operation life, since the observables damages by means of tests mechanics are products of micro-structural effects, induced by neutron irradiation, therefore, is important the study and prediction of the neutron flux to have a better knowledge of the damage that are receiving these materials. In our calculation the code DORT was used, which solves the transport equation in discreet coordinates and in two dimensions (x-y, r-{theta} and r-z), in accord to the regulator guide, it requires to make and approach of the neutron flux in three dimensions by means of the Synthesis Method. Whit this method is possible to achieve a representation of the flux in 3D combining or synthesizing the calculated fluxes by DORT code in r-{theta}, r-z and r. In this work the application of the Synthesis Method is presented, according to the Regulator Guide 1.190, to determine the fluxes 3D in the interns of a BWR using three different space meshes. (Author)

  2. Spectral Flux of the p-(7)Li(C) Q-M Neutron Source Measured by Proton Recoil Telescope

    Czech Academy of Sciences Publication Activity Database

    Bém, Pavel; Götz, Miloslav; Šimečková, Eva; Štefánik, Milan; Fischer, U.; Simakov, SP.; Honusek, Milan; Novák, Jan

    2011-01-01

    Roč. 59, č. 2 (2011), s. 1577-1580 ISSN 0374-4884 Institutional research plan: CEZ:AV0Z10480505 Keywords : ND2010 * Nuclear data * Neutron sources * Quasi-monoenergetic spectrum * Neutron detection Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.447, year: 2011

  3. First In-Core Simultaneous Measurements of Nuclear Heating and Thermal Neutron Flux Obtained With the Innovative Mobile Calorimeter CALMOS Inside the OSIRIS Reactor

    Science.gov (United States)

    Carcreff, Hubert; Salmon, Laurent; Bubendorff, Jacques; Lepeltier, Valérie

    2016-10-01

    Nuclear heating inside a MTR reactor has to be known in order to design and run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. Calorimeter working modes, measurement procedures, main modeling and experimental results and expected advantages of this new technique have been already presented in previous papers. However, these first in-core measurements were not performed beyond 6 W · g-1, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 1014 n · cm-2 · s-1 and nuclear heating up to 12 W · g-1. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a comparison is made between results obtained by the probe calibration coefficient and the zero methods. Thermal neutron flux evaluation from SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with recent experimental data obtained up to 12 W · g-1. Finally, the experience feedback led us to improvement perspectives. A second device is

  4. Influence of Different Moderator Materials on Characteristics of Neutron Fluxes Generated under Irradiation of Lead Target with Proton Beams

    CERN Document Server

    Sosnin, A N; Polanski, A; Petrochenkov, S A; Golovatyuk, V M; Krivopustov, M I; Bamblevski, V P; Westmeier, W; Odoj, R; Brandt, R; Robotham, H; Hashemi-Nezhad, S R; Zamani-Valassiadou, M

    2002-01-01

    Neutron fields generated in extended heavy (Z\\geq 82) targets under irradiation with proton beams at energies in the range of 1 GeV are investigated. Influence of different moderators on the spectra and multiplicities of neutrons escaping the surface of the assembly consisting of a lead target (\\varnothing 8 cm\\times 20 cm or \\varnothing 8cm\\times 50 cm) screened by variable thickness of polyethylene or graphite, respectively, was compared in the present work. It is shown that the effectiveness of graphite as a material used in such assemblies to moderate spallation neutrons down to thermal energies is significantly lower than that of paraffin.

  5. Calibration of the nuclear power channels of the IPEN/MB-01 reactor obtained from the measurements of the spatial thermal neutron flux distribution in the reactor core through the irradiation of infinitely diluted gold foils

    International Nuclear Information System (INIS)

    Goncalves, Lucas Batista

    2008-01-01

    Several nuclear parameters are obtained through the gamma spectrometry of targets irradiated in a research reactor core and this is the case of the activation foils which make possible, through the measurements of the activity induced, to determine the neutron flux in the place where they had been irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. This work aims to get the power operation of the reactor through of spatial neutron flux distribution in the core of IPEN/MB-01 reactor by the irradiation of infinitely diluted gold foils and prudently located in its interior. These foils were made in the form of metallic alloy in concentration levels such that the phenomena of flux disturbance, as the self-shielding factors to neutrons become worthless. These activation foils has only 1% of dispersed gold atoms in an aluminium matrix content of 99% of this element. The irradiations of foils have been carried through with and without cadmium plate. The total correlation between the average thermal neutron flux obtained by irradiation of infinitely diluted activation foils and the average digital value of current of the nuclear power channels 5 and 6 (non-compensated ionization chambers - CINC), allow the calibration of the nuclear channels of the IPEN/MB-01 reactor. (author)

  6. The diffusional pulsed cooling of the thermal neutron flux in small two-region systems. Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Wiacek, U.

    2006-06-01

    The thermal neutron transport in small unhomogeneous system and namely in two- layers where the first one -outer moderator is of hydride type (polyethylene or plexiglas) and the second one - inner is made with other materials is investigated. The diffusional cooling of neutrons has been calculated by means of monte Carlo simulations using MCPN code. Because of un consistency of calculated and measured data the MCPN code library has been modified for polyethylene and plexiglas

  7. High-flux white neutron source based on p(35)-Be reactions for activation experiments at NPI

    Czech Academy of Sciences Publication Activity Database

    Štefánik, Milan; Bém, Pavel; Götz, Miloslav; Katovsky, K.; Majerle, Mitja; Novák, Jan; Šimečková, Eva

    2014-01-01

    Roč. 104, NOV (2014), s. 306-309 ISSN 0969-806X. [1st International Conference on Dosimetry and its Applications (ICDA). Prague, 23.6.2013-28.6.2013] R&D Projects: GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : neutron generator * accelerator * dosimetry foils activation method * neutron spectrometry * Gamma-spectrometry * reaction rate Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.380, year: 2014

  8. Measurements of the neutron capture cross sections and incineration potentials of minor-actinides in high thermal neutron fluxes: Impact on the transmutation of nuclear wastes; Mesures des sections efficaces de capture et potentiels d'incineration des actinides mineurs dans les hauts flux de neutrons: Impact sur la transmutation des dechets

    Energy Technology Data Exchange (ETDEWEB)

    Bringer, O

    2007-10-15

    This thesis comes within the framework of minor-actinide nuclear transmutation studies. First of all, we have evaluated the impact of minor actinide nuclear data uncertainties within the cases of {sup 241}Am and {sup 237}Np incineration in three different reactor spectra: EFR (fast), GT-MHR (epithermal) and HI-HWR (thermal). The nuclear parameters which give the highest uncertainties were thus highlighted. As a result of fact, we have tried to reduce data uncertainties, in the thermal energy region, for one part of them through experimental campaigns in the moderated high intensity neutron fluxes of ILL reactor (Grenoble). These measurements were focused onto the incineration and transmutation of the americium-241, the curium-244 and the californium-249 isotopes. Finally, the values of 12 different cross sections and the {sup 241}Am isomeric branching ratio were precisely measured at thermal energy point. (author)

  9. Neutron-Induced Failures in Semiconductor Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-06

    This slide presentation explores single event effect, environmental neutron flux, system response, the Los Alamos Neutron Science Center (LANSCE) neutron testing facility, examples of SEE measurements, and recent interest in thermal neutrons.

  10. APPLE-3: improvement of APPLE for neutron and gamma-ray flux, spectrum and reaction rate plotting code, and of its code manual

    International Nuclear Information System (INIS)

    Kawasaki, Hiromitu; Maki, Koichi; Seki, Yasushi.

    1991-03-01

    A code APPLE was produced in 1976 for calculating and plotting tritium breeding ratio and tritium production rate distributions. That code was improved as 'APPLE-2' in 1982, to calculate and plot not only tritium breeding ratio but also distributions of neutron and gamma-ray fluxes, their spectra, nuclear heating rates and other reaction rates, and dose rate distributions during operation and after shutdown in 1982. The code APPLE-2 can calculate and plot these nuclear properties derived from neutron and gamma-ray fluxes by ANISN (one dimensional transport code), DOT3.5 (two dimensional transport code) and MORSE (three dimensional Monte Carlo code). We revised the code APPLE-2 as 'APPLE-3' by adding many functions to the APPLE-2 code in accordance with users' requirements proposed in recent progress of fusion reaction nuclear design. With minor modification of APPLE-2, a number of inconsistencies have been found between the code manual and the input data in the code. In the present report, the new functions added to APPLE-2 and improved users' manual are explained. (author)

  11. Characterization of the neutron flux in the Hohlraum of the thermal column of the TRIGA Mark III reactor of the ININ; Caracterizacion del flujo neutronico en el Hohlraum de la columna termica del reactor TRIGA Mark III del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Delfin L, A.; Palacios, J.C.; Alonso, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: adl@nuclear.inin.mx

    2006-07-01

    Knowing the magnitude of the neutron flux in the reactor irradiation facilities, is so much importance for the operation of the same one, like for the investigation developing. Particularly, knowing with certain precision the spectrum and the neutron flux in the different positions of irradiation of a reactor, it is essential for the evaluation of the results obtained for a certain irradiation experiment. The TRIGA Mark III reactor account with irradiation facilities designed to carry out experimentation, where the reactor is used like an intense neutron source and gamma radiation, what allows to make irradiations of samples or equipment in radiation fields with components and diverse levels in the different facilities, one of these irradiation facilities is the Thermal Column where the Hohlraum is. In this work it was carried out a characterization of the neutron flux inside the 'Hohlraum' of the irradiation facility Thermal Column of the TRIGA Mark III reactor of the Nuclear Center of Mexico to 1 MW of power. It was determined the sub cadmic neutron flux and the epi cadmic by means of the neutron activation technique of thin sheets of gold. The maps of the distribution of the neutron flux for both energy groups in three different positions inside the 'Hohlraum' are presented, these maps were obtained by means of the irradiation of undressed thin activation sheets of gold and covered with cadmium in arrangements of 10 x 12, located parallel to 11.5 cm, 40.5 cm and 70.5 cm to the internal wall of graphite of the installation in inverse address to the position of the reactor core. Starting from the obtained values of neutron flux it was found that, for the same position of the surface of irradiation of the experimental arrangement, the relative differences among the values of neutron flux can be of 80%, and that the differences among different positions of the irradiation surfaces can vary until in a one order of magnitude. (Author)

  12. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  13. Neutron in biology

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1997-01-01

    Neutron in biology can provide an experimental method of directly locating relationship of proteins and DNA. However, there are relatively few experimental study of such objects since it takes a lot of time to collect a sufficient number of Bragg reflections and inelastic spectra due to the low flux of neutron illuminating the sample. Since a next generation neutron source of JAERI will be 5MW spallation neutron source and its effective neutron flux will be 10 2 to 10 3 times higher than the one of JRR-3M, neutron in biology will open a completely new world for structural biology. (author)

  14. Local Neutron Flux Distribution Measurements by Wire-Dosimetry in the AMMON Experimental Program in the EOLE Reactor

    Directory of Open Access Journals (Sweden)

    Gruel A.

    2016-01-01

    Full Text Available Dosimetry measurements were carried out during the AMMON experimental program, in the EOLE facility. Al-0.1 wt% Au wires were positioned along curved fuel plates of JHR-type assemblies to investigate the azimuthal and axial gold capture rate profiles, directly linked to the thermal and epithermal flux. After irradiation, wires were cut into small segments (a few mm, and the gold capture rate of each part was measured by gamma spectrometry on the MADERE platform. This paper presents results in the “hafnium” configuration, and more specifically the azimuthal flux profile characterization. The final uncertainty on each measured wire lies below 1% (at 2 standard deviations. Experimental profiles are in a good agreement against Monte Carlo calculations, and the 4% capture rate increase at the plate edge is well observed. The flux dissymmetry due to assembly position in the core is also measured, and shows a 10% discrepancy between the two edges of the plate.

  15. TEM and SEM study of nano SiO2 particles exposed to influence of neutron flux

    Directory of Open Access Journals (Sweden)

    Elchin Huseynov

    2016-07-01

    Full Text Available Before and after neutron irradiation, in order to identify the “adhesion” in silica nanoparticles, analyses have been conducted on transmission electron microscope (TEM at small nano dimensions. Simultaneously, at relatively larger nano dimensions, the surfaces of the samples were observed by the scanning electron microscope (SEM. Moreover, analyses of the samples with SAED (selected area electron diffraction technology on TEM device used for determining the structure of the nanomaterial. From TEM analyses, it has been found that little “adhesion” is observed at small dimensions (maximum 70 nm under the influence of neutron irradiation and this “adhesion” directly influences the electrophysical properties of nanomaterials.

  16. How to calculate uncertainties of neutron flux parameters and uncertainties of analysis results in k(0)-NAA?

    Czech Academy of Sciences Publication Activity Database

    Kubešová, Marie; Kučera, Jan

    2012-01-01

    Roč. 293, č. 1 (2012), s. 87-94 ISSN 0236-5731 R&D Projects: GA ČR GA202/09/0363; GA ČR GD202/09/H086 Institutional support: RVO:61389005 Keywords : neutron activation analysis * K(0) standardization * uncertainty * kragten approach Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.467, year: 2012

  17. New experimental space for irradiating samples by RA reactor fast neutron flux at temperatures up to 100 deg C

    International Nuclear Information System (INIS)

    Pavicevic, M.; Novakovic, M.; Zecevic, V.

    1961-01-01

    The objective of this paper is to present adaptation of the RA reactor which would enable samples irradiation by fast neutrons and describe new experimental possibilities. New experimental space was achieved using hollow fuel elements which have been reconstructed to enable placement of irradiation capsules inside the tube. This paper includes thermal analysis and describes problems related to operation, safety and radiation protection issues which arise from using reconstructed fuel elements

  18. The computer card Accuspec FMS-Canberra in the relaxation time of thermal neutron flux pulses measuring system; Karta komputerowa Accuspec FMS-Canberra w systemie pomiaru stalej zaniku impulsowego strumienia neutronow termicznych

    Energy Technology Data Exchange (ETDEWEB)

    Igielski, A.; Burda, J.; Gabanska, B.; Krynicka, E. [The H. Niewodniczanski Inst. of Nuclear Physics, Cracow (Poland)

    1997-12-31

    In this paper the theoretical basis and a measuring method of the relaxation time of pulsed thermal neutron flux is described. The developed measuring system based on the Accuspec FMS computer card of Canberra is presented. The methods of testing and test results are also described 8 refs, 5 figs, 3 tabs

  19. 14 MeV calibration of JET neutron detectors—phase 1: calibration and characterization of the neutron source

    Science.gov (United States)

    Batistoni, P.; Popovichev, S.; Cufar, A.; Ghani, Z.; Giacomelli, L.; Jednorog, S.; Klix, A.; Lilley, S.; Laszynska, E.; Loreti, S.; Packer, L.; Peacock, A.; Pillon, M.; Price, R.; Rebai, M.; Rigamonti, D.; Roberts, N.; Tardocchi, M.; Thomas, D.; Contributors, JET

    2018-02-01

    In view of the planned DT operations at JET, a calibration of the JET neutron monitors at 14 MeV neutron energy is needed using a 14 MeV neutron generator deployed inside the vacuum vessel by the JET remote handling system. The target accuracy of this calibration is  ±10% as also required by ITER, where a precise neutron yield measurement is important, e.g. for tritium accountancy. To achieve this accuracy, the 14 MeV neutron generator selected as the calibration source has been fully characterised and calibrated prior to the in-vessel calibration of the JET monitors. This paper describes the measurements performed using different types of neutron detectors, spectrometers, calibrated long counters and activation foils which allowed us to obtain the neutron emission rate and the anisotropy of the neutron generator, i.e. the neutron flux and energy spectrum dependence on emission angle, and to derive the absolute emission rate in 4π sr. The use of high resolution diamond spectrometers made it possible to resolve the complex features of the neutron energy spectra resulting from the mixed D/T beam ions reacting with the D/T nuclei present in the neutron generator target. As the neutron generator is not a stable neutron source, several monitoring detectors were attached to it by means of an ad hoc mechanical structure to continuously monitor the neutron emission rate during the in-vessel calibration. These monitoring detectors, two diamond diodes and activation foils, have been calibrated in terms of neutrons/counts within  ±5% total uncertainty. A neutron source routine has been developed, able to produce the neutron spectra resulting from all possible reactions occurring with the D/T ions in the beam impinging on the Ti D/T target. The neutron energy spectra calculated by combining the source routine with a MCNP model of the neutron generator have been validated by the measurements. These numerical tools will be key in analysing the results from the in

  20. ON THE EVOLUTION OF THE INNER DISK RADIUS WITH FLUX IN THE NEUTRON STAR LOW-MASS X-RAY BINARY SERPENS X-1

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Chia-Ying; Morgan, Robert A.; Cackett, Edward M. [Department of Physics and Astronomy, Wayne State University, 666 W. Hancock, Detroit, MI 48202 (United States); Miller, Jon M. [Department of Astronomy, The University of Michigan, 500 Church Street, Ann Arbor, MI 48109-1046 (United States); Bhattacharyya, Sudip [Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, Mumbai 400005 (India); Strohmayer, Tod E., E-mail: ft8320@wayne.edu [X-Ray Astrophysics Lab, Astrophysics Science Division, NASA’s Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2016-11-01

    We analyze the latest Suzaku observation of the bright neutron star (NS) low-mass X-ray binary Serpens X-1 taken in 2013 October and 2014 April. The observation was taken using the burst mode and only suffered mild pile-up effects. A broad iron line is clearly detected in the X-ray spectrum. We test different models and find that the iron line is asymmetric and best interpreted by relativistic reflection. The relativistically broadened iron line is generally believed to originate from the innermost regions of the accretion disk, where strong gravity causes a series of special and general relativistic effects. The iron line profile indicates an inner radius of ∼8 R {sub G}, which gives an upper limit on the size of the NS. The asymmetric iron line has been observed in a number of previous observations, which gives several inner radius measurements at different flux states. We find that the inner radius of Serpens X-1 does not evolve significantly over the range of L / L {sub Edd} ∼ 0.4–0.6, and the lack of flux dependence of the inner radius implies that the accretion disk may be truncated outside of the innermost stable circular orbit by the boundary layer, rather than the stellar magnetic field.