WorldWideScience

Sample records for absolute frequency reference

  1. Frequency reference in VSAT

    Science.gov (United States)

    Cheah, Jonathon Y. C.

    1994-02-01

    A low cost technique of frequency reference distribution within a VSAT network is discussed. This technique allows the use of a modestly frequency stable oscillator as the master frequency reference in the hub of a star-connected VSAT network. The need for extremely frequency stable OCXOs in VSATs is completely avoided. This technique was successfully incorporated in the early commercial VSAT networks. It contributes partially to the low cost nature of some of the VSAT networks available today.

  2. Iodine frequency references for space

    International Nuclear Information System (INIS)

    Schuldt, Thilo; Braxmaier, Claus; Döringshoff, Klaus; Peters, Achim; Oswald, Markus; Johann, Ulrich

    2017-01-01

    Optical frequency references are a key element for the realization of future space missions. They are needed for missions related to tests of fundamental physics, gravitational wave detection, Earth observation and navigation and ranging. In missions such as GRACE follow-on or LISA the optical frequency reference is used as light source for high-sensitivity inter-satellite distance metrology. While cavity-based systems are current baseline e.g. for LISA, frequency stabilization on a hyperfine transition in molecular iodine near 532 nm is a promising alternative. Due to its absolute frequency, iodine standards crucially simplify the initial spacecraft acquisition procedures. Current setups fulfill the GRACE-FO and LISA frequency stability requirements and are realized near Engineering Model level. We present the current status of our developments on Elegant Breadboard (EBB) and Engineering Model (EM) level taking into account specific design criteria for space compatibility such as compactness (size iodine spectroscopy EM: 38 × 18 × 10 cm 3 ) and robustness. Both setups achieved similar frequency stabilities of ∼ 1 · 10 −14 at an integration time of 1 s and below 5 · 10 −15 at integration times between 10 s and 1000 s. Furthermore, we present an even more compact design currently developed for a sounding rocket mission with launch in 2017. (paper)

  3. Iodine frequency references for space

    Science.gov (United States)

    Schuldt, Thilo; Döringshoff, Klaus; Oswald, Markus; Johann, Ulrich; Peters, Achim; Braxmaier, Claus

    2017-05-01

    Optical frequency references are a key element for the realization of future space missions. They are needed for missions related to tests of fundamental physics, gravitational wave detection, Earth observation and navigation and ranging. In missions such as GRACE follow-on or LISA the optical frequency reference is used as light source for high-sensitivity inter-satellite distance metrology. While cavity-based systems are current baseline e.g. for LISA, frequency stabilization on a hyperfine transition in molecular iodine near 532 nm is a promising alternative. Due to its absolute frequency, iodine standards crucially simplify the initial spacecraft acquisition procedures. Current setups fulfill the GRACE-FO and LISA frequency stability requirements and are realized near Engineering Model level. We present the current status of our developments on Elegant Breadboard (EBB) and Engineering Model (EM) level taking into account specific design criteria for space compatibility such as compactness (size iodine spectroscopy EM: 38 × 18 × 10 cm3) and robustness. Both setups achieved similar frequency stabilities of ˜ 1 · 10-14 at an integration time of 1 s and below 5 · 10-15 at integration times between 10 s and 1000 s. Furthermore, we present an even more compact design currently developed for a sounding rocket mission with launch in 2017.

  4. Electrothermal frequency reference

    NARCIS (Netherlands)

    Makinwa, K.A.A.; Kashmiri, S.M.

    2011-01-01

    An electrothermal frequency-locked loop (EFLL) circuit is described. This EFLL circuit includes an oscillator in a feedback loop. A drive circuit in the EFLL circuit generates a first signal having a fundamental frequency, and an electrothermal filter (ETF) in the EFLL circuit provides a second

  5. Frequency Windows of Absolute Negative Conductance in Josephson Junctions

    OpenAIRE

    Machura, L.; Kostur, M.; Talkner, P.; Hanggi, P.; Luczka, J.

    2007-01-01

    We report on anomalous conductance in a resistively and capacitively shunted Josephson junction which is simultaneously driven by ac and dc currents. The dependence of the voltage across the junction on the frequency of the ac current shows windows of absolute negative conductance regimes, i.e. for a positive (negative) dc current, the voltage is negative (positive).

  6. The absolute frequency of the 87Sr optical clock transition

    DEFF Research Database (Denmark)

    Campbell, Gretchen K.; Ludlow, Andrew D.; Blatt, Sebastian

    2008-01-01

    The absolute frequency of the 1S0–3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6 × 10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After...... a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice clock to 1.5 × 10-16, the clock frequency is measured against a hydrogen maser which is simultaneously calibrated to the US primary frequency standard, the NIST Cs fountain clock, NIST-F1. The comparison...... is made possible using a femtosecond laser based optical frequency comb to phase coherently connect the optical and microwave spectral regions and by a 3.5 km fibre transfer scheme to compare the remotely located clock signals....

  7. New Reference Models for Pacific Absolute Plate Motion

    Science.gov (United States)

    Wessel, P.

    2012-12-01

    Absolute plate motion (APM) models are commonly derived by assuming that age-progressive seamount chains represent the surface expressions of mantle plumes; the chain geometries thus record the relative motion between plumes and plates. Traditionally, plumes have been assigned zero motion (i.e., the fixed hotspot hypothesis), and with this assumption the trails directly reflect plate motion. However, since the early 1970s arguments from sedimentary facies and marine magnetics have been marshaled against the fixity of hotspots, perhaps culminating with more recent and direct inferences of anomalous paleolatitudes for several seamounts in both the Emperor and Louisville chains. These data can broadly be explained by drifting plumes, but paleomagnetic data remain scarce and may allow for some true polar wander; furthermore, several age progressions are incomplete or inconsistent and the present locations of some hotspots are uncertain. Finally, APM models with moving hotspots derive largely from mantle flow modeling whose predictions do not match observations directly. Here, I present new absolute plate motion models for the Pacific plate back to 150 Ma. The first model assumes fixed hotspots and is meant to serve as a reference model representing the classic fixed hotspot hypothesis. It is an updated version of the Wessel and Kroenke [2008] model but now including all available chains, recently published age data and processed using improved modeling techniques. The second model uses the same data but also attempts to honor available data on hotspot mobility. It is intended to be a "work in progress" model that will be updated as additional paleolatitude or age data become available. These models can serve as test beds for tectonic hypothesis and be used to identify seamount chain segments where additional paleomagnetic or age observations would have the most impact.

  8. Absolute frequencies of water lines near 790 nm with 10-11 accuracy

    Science.gov (United States)

    Chen, J.; Hua, T.-P.; Tao, L.-G.; Sun, Y. R.; Liu, A.-W.; Hu, S.-M.

    2018-01-01

    Water lines in the infrared are convenient frequency references. We present absolute positions of several H216O ro-vibrational transitions around 790 nm using comb-locked cavity ring-down saturation spectroscopy. Lamb dips of 6 water lines with saturation power in the range of 70-130 kW/cm2 were observed and the line positions were determined with an accuracy of 25 kHz, corresponding to a fractional uncertainty of 6.6 × 10-11. The present work demonstrates the capability to considerably improve the accuracy of the water line positions in the infrared.

  9. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    Science.gov (United States)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  10. The Path to an Up-to-date Absolute Gravity Reference System

    Science.gov (United States)

    Wilmes, H.; Falk, R.; Wziontek, H.

    2014-12-01

    The determination of precise gravity field parameters is of great importance in a period in which earth sciences are achieving the necessary accuracy to monitor and document global change processes. This is the reason why experts from geodesy and metrology joined in a successful cooperation to make absolute gravity observations traceable to SI quantities, to improve the metrological kilogram definition and to monitor mass movements and smallest height changes for geodetic and geophysical applications. How can we determine such a gravity reference system and secure it over multiple decades? Precise knowledge of the gravity acceleration and definition of standards, models and corrections are an important prerequisite to the definition of the gravity system. Over more than three decades, the absolute gravity community cooperated successfully to obtain the gravity reference in comparisons at intervals of 4 years and to certify metrological equivalence between National Metrology Institutes. With increasing resolution of the absolute gravimeter sensors and new measurement principles it becomes obvious that such comparisons are not sufficient for all applications. Mainly for geodetic purposes it is necessary to sub-divide comparison intervals and maintain a connected network of gravity reference sites where compared absolute gravimeters operate together with superconducting gravimeters to derive a continuous gravity reference function. By means of this distributed monitoring of the gravity reference it will also be possible to relate observations of earlier absolute gravimeters to the present-day and to future instruments. It will be possible to include new sensors like atom interferometers and in future to relate the results of precise optical clocks. With co-located space geodetic sensors like GNSS, SLR and VLBI, these reference sites fulfill the conditions of a geodetic fundamental station as a component of IAG's Global Geodetic Observing System.

  11. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  12. High-precision absolute distance measurement using dual-laser frequency scanned interferometry under realistic conditions

    International Nuclear Information System (INIS)

    Yang, H.-J.; Nyberg, Sven; Riles, Keith

    2007-01-01

    In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. Dual lasers with oppositely scanning directions, combined with a multi-distance-measurement technique previously reported, were used to cancel drift errors and to suppress vibration effects and interference fringe uncertainties. Under realistic conditions, a precision about 0.2μm was achieved for a distance of 0.41m. With a precision that exceeds requirements, the frequency scanned interferometry is a promising high-precision optical alignment technique for International Linear Collider silicon tracker detector

  13. Quantifying discipline practices using absolute versus relative frequencies: clinical and research implications for child welfare.

    Science.gov (United States)

    Lindhiem, Oliver; Shaffer, Anne; Kolko, David J

    2014-01-01

    In the parent intervention outcome literatures, discipline practices are generally quantified as absolute frequencies or, less commonly, as relative frequencies. These differences in methodology warrant direct comparison as they have critical implications for study results and conclusions among treatments targeted at reducing parental aggression and harsh discipline. In this study, we directly compared the absolute frequency method and the relative frequency method for quantifying physically aggressive, psychologically aggressive, and nonaggressive discipline practices. Longitudinal data over a 3-year period came from an existing data set of a clinical trial examining the effectiveness of a psychosocial treatment in reducing parental physical and psychological aggression and improving child behavior (N = 139). Discipline practices (aggressive and nonaggressive) were assessed using the Conflict Tactics Scale. The two methods yielded different patterns of results, particularly for nonaggressive discipline strategies. We suggest that each method makes its own unique contribution to a more complete understanding of the association between parental aggression and intervention effects.

  14. Simplified absolute phase retrieval of dual-frequency fringe patterns in fringe projection profilometry

    Science.gov (United States)

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-04-01

    In fringe projection profilometry, a simplified method is proposed to recover absolute phase maps of two-frequency fringe patterns by using a unique mapping rule. The mapping rule is designed from the rounded phase values to the fringe order of each pixel. Absolute phase can be recovered by the fringe order maps. Unlike the existing techniques, where the lowest frequency of dual- or multiple-frequency fringe patterns must be single, the presented method breaks the limitation and simplifies the procedure of phase unwrapping. Additionally, due to many issues including ambient light, shadow, sharp edges, step height boundaries and surface reflectivity variations, a novel framework of automatically identifying and removing invalid phase values is also proposed. Simulations and experiments have been carried out to validate the performances of the proposed method.

  15. Absolute frequency measurement of the 1S0 - 3P0 transition of 171Yb

    International Nuclear Information System (INIS)

    Pizzocaro, Marco; Thoumany, Pierre; Clivati, Cecilia; Levi, Filippo; Calonico, Davide; Rauf, Benjamin; Bregolin, Filippo; Milani, Gianmaria

    2017-01-01

    We report the absolute frequency measurement of the unperturbed transition 1 S 0 - 3 P 0 at 578 nm in 171 Yb realized in an optical lattice frequency standard relative to a cryogenic caesium fountain. The measurement result is 518 295 836 590 863.59(31) Hz with a relative standard uncertainty of 5.9 10 * 10 -16 . This value is in agreement with the ytterbium frequency recommended as a secondary representation of the second in the International System of Units. (authors)

  16. Ultra-low-frequency vertical vibration isolator based on a two-stage beam structure for absolute gravimetry

    Science.gov (United States)

    Wang, G.; Wu, K.; Hu, H.; Li, G.; Wang, L. J.

    2016-10-01

    To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.

  17. Defining an absolute reference frame for 'clumped' isotope studies of CO 2

    Science.gov (United States)

    Dennis, Kate J.; Affek, Hagit P.; Passey, Benjamin H.; Schrag, Daniel P.; Eiler, John M.

    2011-11-01

    We present a revised approach for standardizing and reporting analyses of multiply substituted isotopologues of CO 2 (i.e., 'clumped' isotopic species, especially the mass-47 isotopologues). Our approach standardizes such data to an absolute reference frame based on theoretical predictions of the abundances of multiply-substituted isotopologues in gaseous CO 2 at thermodynamic equilibrium. This reference frame is preferred over an inter-laboratory calibration of carbonates because it enables all laboratories measuring mass 47 CO 2 to use a common scale that is tied directly to theoretical predictions of clumping in CO 2, regardless of the laboratory's primary research field (carbonate thermometry or CO 2 biogeochemistry); it explicitly accounts for mass spectrometric artifacts rather than convolving (and potentially confusing) them with chemical fractionations associated with sample preparation; and it is based on a thermodynamic equilibrium that can be experimentally established in any suitably equipped laboratory using commonly available materials. By analyzing CO 2 gases that have been subjected to established laboratory procedures known to promote isotopic equilibrium (i.e., heated gases and water-equilibrated CO 2), and by reference to thermodynamic predictions of equilibrium isotopic distributions, it is possible to construct an empirical transfer function that is applicable to data with unknown clumped isotope signatures. This transfer function empirically accounts for the fragmentation and recombination reactions that occur in electron impact ionization sources and other mass spectrometric artifacts. We describe the protocol necessary to construct such a reference frame, the method for converting gases with unknown clumped isotope compositions to this reference frame, and suggest a protocol for ensuring that all reported isotopic compositions (e.g., Δ 47 values; Eiler and Schauble, 2004; Eiler, 2007) can be compared among different laboratories and

  18. New design and facilities for the International Database for Absolute Gravity Measurements (AGrav): A support for the Establishment of a new Global Absolute Gravity Reference System

    Science.gov (United States)

    Wziontek, Hartmut; Falk, Reinhard; Bonvalot, Sylvain; Rülke, Axel

    2017-04-01

    After about 10 years of successful joint operation by BGI and BKG, the International Database for Absolute Gravity Measurements "AGrav" (see references hereafter) was under a major revision. The outdated web interface was replaced by a responsive, high level web application framework based on Python and built on top of Pyramid. Functionality was added, like interactive time series plots or a report generator and the interactive map-based station overview was updated completely, comprising now clustering and the classification of stations. Furthermore, the database backend was migrated to PostgreSQL for better support of the application framework and long-term availability. As comparisons of absolute gravimeters (AG) become essential to realize a precise and uniform gravity standard, the database was extended to document the results on international and regional level, including those performed at monitoring stations equipped with SGs. By this it will be possible to link different AGs and to trace their equivalence back to the key comparisons under the auspices of International Committee for Weights and Measures (CIPM) as the best metrological realization of the absolute gravity standard. In this way the new AGrav database accommodates the demands of the new Global Absolute Gravity Reference System as recommended by the IAG Resolution No. 2 adopted in Prague 2015. The new database will be presented with focus on the new user interface and new functionality, calling all institutions involved in absolute gravimetry to participate and contribute with their information to built up a most complete picture of high precision absolute gravimetry and improve its visibility. A Digital Object Identifier (DOI) will be provided by BGI to contributors to give a better traceability and facilitate the referencing of their gravity surveys. Links and references: BGI mirror site : http://bgi.obs-mip.fr/data-products/Gravity-Databases/Absolute-Gravity-data/ BKG mirror site: http

  19. Thermal-Diffusivity-Based Frequency References in Standard CMOS

    NARCIS (Netherlands)

    Kashmiri, S.M.

    2012-01-01

    In recent years, a lot of research has been devoted to the realization of accurate integrated frequency references. A thermal-diffusivity-based (TD) frequency reference provides an alternative method of on-chip frequency generation in standard CMOS technology. A frequency-locked loop locks the

  20. Absolute scale power measurements of frequency-locked coherent transition radiation

    Directory of Open Access Journals (Sweden)

    Roark A. Marsh

    2007-08-01

    Full Text Available We report the absolute power measurement of frequency-locked terahertz coherent transition radiation (CTR from a train of electron bunches produced by a 17.14 GHz accelerator. Frequency measurements were obtained by two independent techniques: a wave meter with a video diode detector, and a double heterodyne system. Good agreement was seen between these two techniques. The emitted radiation was observed to be a comb of frequencies that are harmonics of the 17.14 GHz accelerator frequency. The heterodyne receiver system showed that each of the emitted harmonics has a very narrow bandwidth, about 25 MHz, which corresponds to the transform-limited bandwidth for the bunch train length of 40 ns. The highest observed frequency was 377.08 GHz, the 22nd harmonic of the 17.14 GHz accelerator frequency. The emitted CTR power was measured on an absolute scale to test the theory of CTR. The power was compared with calculations made using an electric field integral equation (EFIE formulation and excellent agreement was obtained. This agreement serves as a valuable benchmark of the EFIE code, proof of both its validity and usefulness.

  1. Noninvasive absolute cerebral oximetry with frequency-domain near-infrared spectroscopy

    Science.gov (United States)

    Hallacoglu, Bertan

    Near-infrared spectroscopy (NIRS) measurements of absolute concentrations of oxy-hemoglobin and deoxy-hemoglobin in the human brain can provide critical information about cerebral physiology in terms of cerebral blood volume, blood flow, oxygen delivery, and metabolic rate of oxygen. We developed several frequency domain NIRS data acquisition and analysis methods aimed at absolute measurements of hemoglobin concentration and saturation in cerebral tissue of adult human subjects. Extensive experimental investigations were carried out in various homogenous and two-layered tissue-mimicking phantoms, and biological tissues. The advantages and limitations of commonly used homogenous models and inversion strategies were thoroughly investigated. Prior to human subjects, extensive studies were carried out in in vivo animal models. In rabbits, absolute hemoglobin oxygen desaturation was shown to depend strongly on surgically induced testicular torsion. Methods developed in this study were then adapted for measurements in the rat brain. Absolute values were demonstrated to discern cerebrovascular impairment in a rat model of diet-induced vascular cognitive impairment. These results facilitated the development of clinically useful optical measures of cerebrovascular health. In a large group of human subjects, employing a homogeneous model for absolute measurements was shown to be reliable and robust. However, it was also shown to be limited due to the relatively thick extracerebral tissue. The procedure we develop in this work and the thesis thereof performs a nonlinear inversion procedure with six unknown parameters with no other prior knowledge for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and

  2. LARS: An Absolute Reference Spectrograph for solar observations. Upgrade from a prototype to a turn-key system

    Science.gov (United States)

    Löhner-Böttcher, J.; Schmidt, W.; Doerr, H.-P.; Kentischer, T.; Steinmetz, T.; Probst, R. A.; Holzwarth, R.

    2017-10-01

    Context. We designed a Laser-based Absolute Reference Spectrograph (LARS) for ultra-precise solar observations. The high-resolution echelle spectrograph of the Vacuum Tower Telescope is supported by a laser frequency comb to calibrate the solar spectrum on an absolute wavelength scale. In this article, we describe the scientific instrument and focus on the upgrades carried out in the last two years to turn the prototype into a turn-key system. Aims: The goal was to improve the short-term and long-term stability of the systems, and to enable a user-friendly and more versatile operation of the instrument. Methods: The first upgrade involved the modernization of the frequency comb. The laser system generating the comb spectrum was renewed. The Fabry-Pérot cavities were adjusted to filter to a repetition frequency of 8 GHz. A technologically matured photonic crystal fiber was implemented for spectral broadening which simplified and stabilized the setup. The new control software facilitates an automated operation of the frequency comb. The second, quite recent upgrade was performed on the optics which feed the sunlight into a single-mode fiber connected to the spectrograph. A motorized translation stage was deployed to allow the automated selection of three different fields of view with diameters of 1'', 3'', and 10'' for the analysis of the solar spectrum. Results: The successful upgrades allow for long-term observations of up to several hours per day with a stable spectral accuracy of 1 m s-1 limited by the spectrograph. The instrument covers a wavelength range between 480 nm and 700 nm in the visible. Stable, user-friendly operation of the instrument is supported. The selection of the pre-aligned fiber to change the field of view can now be done within seconds. Conclusions: LARS offers the possibility to observe absolute wavelength positions of spectral lines and Doppler velocities in the solar atmosphere. First results demonstrate the capabilities of the instrument

  3. Absolute three-dimensional shape measurement with two-frequency square binary patterns.

    Science.gov (United States)

    Jiang, Chufan; Zhang, Song

    2017-11-01

    This paper presents a novel method to achieve absolute three-dimensional shape measurement solely using square binary patterns. This method uses six patterns: three low-frequency phase-shifted patterns and three phase-shifted high-frequency patterns. The phase obtained from the low-frequency phase temporally unwraps the phase obtained from high-frequency patterns. The projector is defocused such that the high-frequency patterns produce a high-quality phase, but the phase retrieved from low-frequency patterns has a large harmonic error that fails the two-frequency temporal phase unwrapping process. In this paper, we develop a computational framework to address the challenge. The proposed computational framework includes four major approaches to alleviate the harmonic error problem: (i) use more than one period of low-frequency patterns enabled by a geometric constraint-based phase unwrapping method; (ii) artificially apply a large Gaussian filter to low-frequency patterns before phase computation; (iii) create an error lookup table to compensate for harmonic error; and (iv) develop a boundary error correction method to alleviate problems associated with filtering. Both simulation and experimental results demonstrated the success of the proposed method.

  4. Quantifying Discipline Practices Using Absolute vs. Relative Frequencies: Clinical and Research Implications for Child Welfare

    Science.gov (United States)

    Lindhiem, Oliver; Shaffer, Anne; Kolko, David J.

    2014-01-01

    In the parent intervention outcome literatures, discipline practices are generally quantified as absolute frequencies or, less commonly, as relative frequencies. These differences in methodology warrant direct comparison as they have critical implications for study results and conclusions among treatments targeted at reducing parental aggression and harsh discipline. In this study, we directly compared the absolute frequency method and the relative frequency method for quantifying physically aggressive, psychologically aggressive, and nonaggressive discipline practices. Longitudinal data over a 3-year period came from an existing data set of a clinical trial examining the effectiveness of a psychosocial treatment in reducing parental physical and psychological aggression and improving child behavior (N = 139; Kolko et al., 2009). Discipline practices (both aggressive and nonaggressive) were assessed using the Conflict Tactics Scale (CTS; Straus et al., 1998). The two methods yielded different patterns of results, particularly for nonaggressive discipline strategies. We suggest that each method makes its own unique contribution to a more complete understanding of the association between parental aggression and intervention effects. PMID:24106146

  5. Coherent Frequency Reference System for the NASA Deep Space Network

    Science.gov (United States)

    Tucker, Blake C.; Lauf, John E.; Hamell, Robert L.; Gonzaler, Jorge, Jr.; Diener, William A.; Tjoelker, Robert L.

    2010-01-01

    The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex.

  6. Absolute-frequency measurements with a stabilized near-infrared optical frequency comb from a Cr:forsterite laser

    Science.gov (United States)

    Corwin, K. L.; Thomann, I.; Dennis, T.; Fox, R. W.; Swann, W.; Curtis, E. A.; Oates, C. W.; Wilpers, G.; Bartels, A.; Gilbert, S. L.; Hollberg, L.; Newbury, N. R.; Diddams, S. A.; Nicholson, J. W.; Yan, M. F.

    2004-02-01

    A frequency comb is generated with a chromium-doped forsterite femtosecond laser, spectrally broadened in a dispersion-shifted highly nonlinear fiber, and stabilized. The resultant evenly spaced comb of frequencies ranges from 1.1 to beyond 1.8 μm. The frequency comb was referenced simultaneously to the National Institute of Standards and Technology's optical frequency standard based on neutral calcium and to a hydrogen maser that is calibrated by a cesium atomic fountain clock. With this comb we measured two frequency references in the telecommunications band: one half of the frequency of the d/f crossover transition in 87Rb at 780 nm, and the methane ν2 + 2ν3 R(8) line at 1315 nm.

  7. Absolute frequency atlas from 915 nm to 985 nm based on laser absorption spectroscopy of iodine

    Science.gov (United States)

    Nölleke, Christian; Raab, Christoph; Neuhaus, Rudolf; Falke, Stephan

    2018-04-01

    This article reports on laser absorption spectroscopy of iodine gas between 915 nm and 985 nm. This wavelength range is scanned utilizing a narrow linewidth and mode-hop-free tunable diode-laser whose frequency is actively controlled using a calibrated wavelength meter. This allows us to provide an iodine atlas that contains almost 10,000 experimentally observed reference lines with an uncertainty of 50 MHz. For common lines, good agreement is found with a publication by Gerstenkorn and Luc (1978). The new rich dataset allows existing models of the iodine molecule to be refined and can serve as a reference for laser frequency calibration and stabilization.

  8. Have human activities changed the frequencies of absolute extreme temperatures in eastern China?

    Science.gov (United States)

    Wang, Jun; Tett, Simon F. B.; Yan, Zhongwei; Feng, Jinming

    2018-01-01

    Extreme temperatures affect populous regions, like eastern China, causing substantial socio-economic losses. It is beneficial to explore whether the frequencies of absolute or threshold-based extreme temperatures have been changed by human activities, such as anthropogenic emissions of greenhouse gases (GHGs). In this study, we compared observed and multi-model-simulated changes in the frequencies of summer days, tropical nights, icy days and frosty nights in eastern China for the years 1960-2012 by using an optimal fingerprinting method. The observed long-term trends in the regional mean frequencies of these four indices were +2.36, +1.62, -0.94, -3.02 days decade-1. The models performed better in simulating the observed frequency change in daytime extreme temperatures than nighttime ones. Anthropogenic influences are detectable in the observed frequency changes of these four temperature extreme indices. The influence of natural forcings could not be detected robustly in any indices. Further analysis found that the effects of GHGs changed the frequencies of summer days (tropical nights, icy days, frosty nights) by +3.48 ± 1.45 (+2.99 ± 1.35, -2.52 ± 1.28, -4.11 ± 1.48) days decade-1. Other anthropogenic forcing agents (dominated by anthropogenic aerosols) offset the GHG effect and changed the frequencies of these four indices by -1.53 ± 0.78, -1.49 ± 0.94, +1.84 ± 1.07, +1.45 ± 1.26 days decade-1, respectively. Little influence of natural forcings was found in the observed frequency changes of these four temperature extreme indices.

  9. Using saturated absorption spectroscopy on acetylene-filled hollow-core fibers for absolute frequency measurements

    Science.gov (United States)

    Knabe, Kevin

    Current portable near-infrared optical frequency references offer modest accuracy and instability compared to laboratory references. Low pressure reference cells are necessary to realize features narrower than the Doppler broadened overtone transitions, and most setups to date have occurred in free-space. Hollow-core photonic crystal fibers offer a potential alternative to free-space setups through their small cores (˜10's of mum) and low-loss guidance. Furthermore, HC-PCF can be made into fiber cells that could be directly integrated into existing telecommunications networks. Efforts were made to fabricate these fiber cells with a low pressure of molecules trapped inside, but this has proven to be quite challenging. Therefore, investigation of these fibers is conducted by placing the ends of the fiber inside vacuum chambers loaded with acetylene (12C2H2). The linewidths of several P branch nu1 +nu3 transitions (near 1.5 mum) are investigated as a function of acetylene pressure and optical pump power in three different HC-PCFs. Frequency modulation spectroscopy is then implemented on the acetylene-filled HC-PCF to generate sub-Doppler dispersion features that are useful for frequency stabilization using standard servo electronics. Instability and accuracy of this near-IR optical reference were then determined by analysis of heterodyne experiments conducted with frequency combs referenced to a GPS-disciplined rubidium oscillator. The instability and accuracy of this HC-PCF reference are within an order of magnitude of free-space experiments, as expected based on the ratio of linewidths observed in the two experiments. Therefore, HC-PCF has been shown to be suitable for potential frequency references. Further work is necessary to fabricate gas fiber cells with high optical transmission and low molecular contamination.

  10. JOKARUS - design of a compact optical iodine frequency reference for a sounding rocket mission

    Energy Technology Data Exchange (ETDEWEB)

    Schkolnik, Vladimir; Doeringshoff, Klaus; Gutsch, Franz Balthasar; Krutzik, Markus [Humboldt-Universitaet zu Berlin, Berlin (Germany); Oswald, Markus [Universitaet Bremen, Zentrum fuer angewandte Raumfahrttechnologie und Mikrogravitation (ZARM), Bremen (Germany); Schuldt, Thilo [Institut fuer Raumfahrtsysteme, Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Bremen (Germany); Braxmaier, Claus [Universitaet Bremen, Zentrum fuer angewandte Raumfahrttechnologie und Mikrogravitation (ZARM), Bremen (Germany); Institut fuer Raumfahrtsysteme, Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Bremen (Germany); Lezius, Matthias; Holzwarth, Ronald [Menlo Systems GmbH, Martinsried (Germany); Kuerbis, Christian; Bawamia, Ahmad [Leibniz-Institut fuer Hoechstfrequenztechnik, Ferdinand-Braun-Institut, Berlin (Germany); Peters, Achim [Humboldt-Universitaet zu Berlin, Berlin (Germany); Leibniz-Institut fuer Hoechstfrequenztechnik, Ferdinand-Braun-Institut, Berlin (Germany)

    2017-12-15

    We present the design of a compact absolute optical frequency reference for space applications based on hyperfine transitions in molecular iodine with a targeted fractional frequency instability of better than 3 x 10{sup -14} after 1 s. It is based on a micro-integrated extended cavity diode laser with integrated optical amplifier, fiber pigtailed second harmonic generation wave-guide modules, and a quasi-monolithic spectroscopy setup with operating electronics. The instrument described here is scheduled for launch end of 2017 aboard the TEXUS 54 sounding rocket as an important qualification step towards space application of iodine frequency references and related technologies. The payload will operate autonomously and its optical frequency will be compared to an optical frequency comb during its space flight. (orig.)

  11. Dissemination of optical-comb-based ultra-broadband frequency reference through a fiber network.

    Science.gov (United States)

    Nagano, Shigeo; Kumagai, Motohiro; Li, Ying; Ido, Tetsuya; Ishii, Shoken; Mizutani, Kohei; Aoki, Makoto; Otsuka, Ryohei; Hanado, Yuko

    2016-08-22

    We disseminated an ultra-broadband optical frequency reference based on a femtosecond (fs)-laser optical comb through a kilometer-scale fiber link. Its spectrum ranged from 1160 nm to 2180 nm without additional fs-laser combs at the end of the link. By employing a fiber-induced phase noise cancellation technique, the linewidth and fractional frequency instability attained for all disseminated comb modes were of order 1 Hz and 10-18 in a 5000 s averaging time. The ultra-broad optical frequency reference, for which absolute frequency is traceable to Japan Standard Time, was applied in the frequency stabilization of an injection-seeded Q-switched 2051 nm pulse laser for a coherent light detection and ranging LIDAR system.

  12. The web-based ASSO-food frequency questionnaire for adolescents: relative and absolute reproducibility assessment.

    Science.gov (United States)

    Filippi, Anna Rita; Amodio, Emanuele; Napoli, Giuseppe; Breda, João; Bianco, Antonino; Jemni, Monèm; Censi, Laura; Mammina, Caterina; Tabacchi, Garden

    2014-12-17

    A new food frequency questionnaire (FFQ) has been recently developed within the Italian Adolescents and Surveillance System for the Obesity prevention (ASSO) Project; it was found to be appropriate for ranking adolescents in food and nutrient levels of intake. The aim of this study was to assess the relative and absolute reproducibility of the ASSO-FFQ for 24 food groups, energy and 52 nutrients. A test-retest study was performed on two ASSO-FFQs administered one month apart of each other to 185 adolescents, aged 14-17 and attending secondary schools in Palermo (Italy). Wilcoxon test assessed differences in median daily intakes between the two FFQs. Agreement was evaluated by quintiles comparison and weighted kappa. Intraclass Correlation Coefficients (ICC) and Bland-Altman method assessed the relative and absolute reliability respectively. Significant difference (p food, water, soft drinks, carbohydrates and sugar. The subjects classified into the same or adjacent quintiles for food groups ranged from 62% (white bread) to 91% (soft drinks); for energy and nutrients from 64% (polyunsaturated fatty acids) to 90% (ethanol). Mean values of weighted kappa were 0.47 and 0.48, respectively for food groups and nutrients. Fair to good ICC values (>0.40) were assessed for thirteen food groups, energy and forty-three nutrients. Limits of Agreement were narrow for almost all food groups and all nutrients. The ASSO-FFQ is a reliable instrument for estimating food groups, energy and nutrients intake in adolescents.

  13. Traceable Determination of the Absolute Neutron Emission Yields of UO2F2 Working Reference Materials

    International Nuclear Information System (INIS)

    LaFleur, A.M.; Swinhoe, M.T.; Mayo, D.R.; Sapp, B.A.; Croft, S.; Mayer, R.L.

    2013-06-01

    The nuclear material contained in the process equipment of a uranium enrichment plant (referred to as holdup) is an important component of the overall nuclear material inventory for the plant. Accurate quantification and verification of holdup is needed to improve international safeguards and nuclear material accountancy. This is also needed for criticality safety and waste disposition. Passive neutron and gamma-ray nondestructive assay (NDA) methods are used to measure the holdup in process equipment. A key advantage of neutron measurements is that neutrons are highly penetrating and can be measured through thick walled equipment. The dominant source of neutrons in the UO 2 F 2 holdup is from the 19 F(α, n) 22 Na reaction resulting from 234 U alpha decay when uranium is enriched. There is a considerable spread between different historic determinations of the 19 F(α, n) yield from uranium which limits the accuracy of modeling and the calibration of NDA instruments. Furthermore, the compound form and presence of water also significantly affects the neutron emission rate from the holdup. This paper describes a series of experimental measurements performed at Los Alamos National Laboratory (LANL) to determine the absolute neutron emission yield from 10 different UO 2 F 2 working reference materials (WRMs) fabricated at the Portsmouth Gaseous Diffusion Plant (PGDP). The Mini Epithermal Neutron Multiplicity Counter (Mini ENMC) and a NIST certified 252 Cf neutron source were used for these measurements. The high efficiency and short die-away time of the Mini ENMC provides the high measurement precision needed to certify the neutron emission yield. The experiment was designed to achieve sub 1% accuracy in the net counting rate on each item and to provide assurance that important factors such as instrument stability, item placement and background were well understood. The traceable neutron yields measured from the WRMs were used to determine a more accurate neutron yield

  14. Simplified fringe order correction for absolute phase maps recovered with multiple-spatial-frequency fringe projections

    International Nuclear Information System (INIS)

    Ding, Yi; Peng, Kai; Lu, Lei; Zhong, Kai; Zhu, Ziqi

    2017-01-01

    Various kinds of fringe order errors may occur in the absolute phase maps recovered with multi-spatial-frequency fringe projections. In existing methods, multiple successive pixels corrupted by fringe order errors are detected and corrected pixel-by-pixel with repeating searches, which is inefficient for applications. To improve the efficiency of multiple successive fringe order corrections, in this paper we propose a method to simplify the error detection and correction by the stepwise increasing property of fringe order. In the proposed method, the numbers of pixels in each step are estimated to find the possible true fringe order values, repeating the search in detecting multiple successive errors can be avoided for efficient error correction. The effectiveness of our proposed method is validated by experimental results. (paper)

  15. Cusp map in the complex-frequency plane for absolute instabilities

    International Nuclear Information System (INIS)

    Kupfer, K.; Bers, A.; Ram, A.K.

    1987-01-01

    It is well known that absolute instabilities can be located by prescribed mappings from the complex-frequency plane to the wavenumber plane through the dispersion relation D(ω,k) = 0. However, in many systems of physical interest the dispersion relation is polynomial in ω while transcendental in k, and the implementation of this mapping procedure is particularly difficult. If one maps consecutive deformations of the Fourier integral path (originally along the real k axis) into the ω plane, points having (partialD/partialk) = 0 are readily detected by the distinctive feature of their local maps. It is shown that a simple topological relationship between these points and the image of the real k axis determines the stability characteristics of the system, without mapping from the ω plane back into the k-plane

  16. Absolute distance measurement with extension of nonambiguity range using the frequency comb of a femtosecond laser

    Science.gov (United States)

    Jang, Yoon-Soo; Lee, Keunwoo; Han, Seongheum; Lee, Joohyung; Kim, Young-Jin; Kim, Seung-Woo

    2014-12-01

    We revisit the method of synthetic wavelength interferometry (SWI) for absolute measurement of long distances using the radio-frequency harmonics of the pulse repetition rate of a mode-locked femtosecond laser. Our intention here is to extend the nonambiguity range (NAR) of the SWI method using a coarse virtual wavelength synthesized by shifting the pulse repetition rate. The proposed concept of NAR extension is experimentally verified by measuring a ˜13-m distance with repeatability of 9.5 μm (root-mean-square). The measurement precision is estimated to be 31.2 μm in comparison with an incremental He-Ne laser interferometer. This extended SWI method is found to be well suited for long-distance measurements demanded in the fields of large-scale precision engineering, geodetic survey, and future space missions.

  17. Accurate absolute frequencies of the ν1+ν3 band of 13C2H2 determined using an infrared mode-locked Cr:YAG laser frequency comb

    International Nuclear Information System (INIS)

    Madej, Alan A.; Bernard, John E.; John Alcock, A.; Czajkowski, Andrzej; Chepurov, Sergei

    2006-01-01

    Absolute frequency measurements, with up to 1x10 -11 level accuracies, are presented for 60 lines of the P and R branches for the ν 1 +ν 3 band of 13 C 2 H 2 at 1.5 μm (194 THz). The measurements were made using cavity-enhanced, diode-laser-based saturation spectroscopy. With one laser system stabilized to the P(16) line and a second laser system stabilized to the line whose frequency was to be determined, a Cr:YAG frequency comb was employed to accurately measure the tetrahertz level frequency intervals. The results are compared with recent work from other groups and indicate that these lines would form a basis for a high-quality atlas of reference frequencies for this region of the spectrum

  18. Advances in the Metrology of Absolute Value Assignments to Isotopic Reference Materials: Consequences from the Avogadro Project

    Science.gov (United States)

    Vocke, Robert; Rabb, Savelas

    2015-04-01

    All isotope amount ratios (hereafter referred to as isotope ratios) produced and measured on any mass spectrometer are biased. This unfortunate situation results mainly from the physical processes in the source area where ions are produced. Because the ionized atoms in poly-isotopic elements have different masses, such processes are typically mass dependent and lead to what is commonly referred to as mass fractionation (for thermal ionization and electron impact sources) and mass bias (for inductively coupled plasma sources.) This biasing process produces a measured isotope ratio that is either larger or smaller than the "true" ratio in the sample. This has led to the development of numerous fractionation "laws" that seek to correct for these effects, many of which are not based on the physical processes giving rise to the biases. The search for tighter and reproducible precisions has led to two isotope ratio measurement systems that exist side-by-side. One still seeks to measure "absolute" isotope ratios while the other utilizes an artifact based measurement system called a delta-scale. The common element between these two measurement systems is the utilization of isotope reference materials (iRMs). These iRMs are used to validate a fractionation "law" in the former case and function as a scale anchor in the latter. Many value assignments of iRMs are based on "best measurements" by the original groups producing the reference material, a not entirely satisfactory approach. Other iRMs, with absolute isotope ratio values, have been produced by calibrated measurements following the Atomic Weight approach (AW) pioneered by NBS nearly 50 years ago. Unfortunately, the AW is not capable of calibrating the new generation of iRMs to sufficient precision. So how do we get iRMs with isotope ratios of sufficient precision and without bias? Such a focus is not to denigrate the extremely precise delta-scale measurements presently being made on non-traditional and tradition

  19. Fringe order correction for the absolute phase recovered by two selected spatial frequency fringe projections in fringe projection profilometry.

    Science.gov (United States)

    Ding, Yi; Peng, Kai; Yu, Miao; Lu, Lei; Zhao, Kun

    2017-08-01

    The performance of the two selected spatial frequency phase unwrapping methods is limited by a phase error bound beyond which errors will occur in the fringe order leading to a significant error in the recovered absolute phase map. In this paper, we propose a method to detect and correct the wrong fringe orders. Two constraints are introduced during the fringe order determination of two selected spatial frequency phase unwrapping methods. A strategy to detect and correct the wrong fringe orders is also described. Compared with the existing methods, we do not need to estimate the threshold associated with absolute phase values to determine the fringe order error, thus making it more reliable and avoiding the procedure of search in detecting and correcting successive fringe order errors. The effectiveness of the proposed method is validated by the experimental results.

  20. Absolute parametric instability of low-frequency waves in a 2D ...

    Indian Academy of Sciences (India)

    Using the separation method, absolute parametric instability (API) of electrostatic waves in a magnetized pumped warm plasma is investigated. In this case the effect of static strong magnetic field is considered. The problem of strong magnetic field is solved in two-dimensional (2D) nonuniform plane plasma. Equations ...

  1. Possibility of the effect of absolute negative conductivity in quantum superlattice exposed to the high-frequency electromagnetic radiation

    Science.gov (United States)

    Kryuchkov, S. V.; Kukhar', E. I.

    2015-07-01

    Current density in superlattice placed in quantizing electric field and in high-frequency field of electromagnetic wave was calculated. The calculations were performed by taking into account an inelastic scattering of charge carriers by phonons. Possibility of the effect of absolute negative conductivity, i.e. the effect of appearance of electric current flowing in opposite direction than that of vector of quantizing electric field intensity, was shown. Such effect in graphene superlattices was discussed.

  2. Research on spectrum broadening covering visible light of a fiber femtosecond optical frequency comb for absolute frequency measurement

    Science.gov (United States)

    Xing, Shuai; Wu, Tengfei; Li, Shuyi; Xia, Chuanqing; Han, Jibo; Zhang, Lei; Zhao, Chunbo

    2018-03-01

    As a bridge connecting microwave frequency and optical frequency, femtosecond laser has important significance in optical frequency measurement. Compared with the traditional Ti-sapphire femtosecond optical frequency comb, with the advantages of compact structure, strong anti-interference ability and low cost, the fiber femtosecond optical frequency comb has a wider application prospect. An experiment of spectrum broadening in a highly nonlinear photonic crystal fiber pumped by an Er-fiber mode-locked femtosecond laser is studied in this paper. Based on optical amplification and frequency doubling, the central wavelength of the output spectrum is 780nm and the average power is 232mW. With the femtosecond pulses coupled into two different photonic crystal fibers, the coverage of visible spectrum is up to 500nm-960nm. The spectral shape and width can be optimized by changing the polarization state for satisfying the requirments of different optical frequencies measurement.

  3. An ultra-stable optical frequency reference for space

    Science.gov (United States)

    Schuldt, T.; Döringshoff, K.; Kovalchuk, E.; Pahl, J.; Gohlke, M.; Weise, D.; Johann, U.; Peters, A.; Braxmaier, C.

    2017-11-01

    We realized ultra-stable optical frequency references on elegant breadboard (EBB) and engineering model (EM) level utilizing Doppler-free spectroscopy of molecular iodine near 532nm. A frequency stability of about 1•10-14 at an integration time of 1 s and below 5•10-15 at integration times between 10 s and 100 s was achieved. These values are comparable to the currently best laboratory setups. Both setups use a baseplate made of glass material where the optical components are joint using a specific assembly-integration technology. Compared to the EBB setup, the EM setup is further developed with respect to compactness and mechanical and thermal stability. The EM setup uses a baseplate made of fused silica with dimensions of 380 x 180 x 40 mm3 and a specifically designed 100 x 100 x 30 mm3 rectangular iodine cell in nine-pass configuration with a specific robust cold finger design. The EM setup was subjected to thermal cycling and vibrational testing. Applications of such an optical frequency reference in space can be found in fundamental physics, geoscience, Earth observation, and navigation & ranging. One example is the proposed mSTAR (mini SpaceTime Asymmetry Research) mission, dedicated to perform a Kennedy-Thorndike experiment on a satellite in a sunsynchronous low-Earth orbit. By comparing an iodine standard to a cavity-based frequency reference and integration over 2 year mission lifetime, the Kennedy-Thorndike coefficient will be determined with up to two orders of magnitude higher accuracy than the current best ground experiment. In a current study, the compatibility of the payload with the SaudiSat-4 host vehicle is investigated.

  4. The absolute frequency reference unit for the methane-sensing lidar mission Merlin

    Science.gov (United States)

    Heinecke, D.; Liebherr, T.; Diekmann, C.; Baatzsch, A.; Herding, M.; Taha, M.; Birmuske, R.; Wang, X.; Battles, D.; Dahl, K.; Kiewe, B.; Schleisiek, K.; Beller, N.; Schafer, H.; Nicklaus, K.

    2017-09-01

    The French-German Methane Remote Sensing LIDAR Mission (MERLIN) planned for launch in 2020 aims to provide a global methane concentration map. The instrument is a differential absorption LIDAR (DIAL) system measuring the column-weighted dry-air mixing ratios of methane with a horizontal resolution of 50 km employing an absorption line at 1645 nm [1].

  5. Stabilization of the Absolute Frequency and Phase of a Compact, Low Jitter Modelocked Semiconductor Diode Laser

    National Research Council Canada - National Science Library

    Delfyett, Peter J., Jr

    2005-01-01

    .... To achieve this, an intracavity Pound-Drever-Hall technique was used on a 10 GHz harmonically mode-locked semiconductor ring laser and obtained a simultaneous optical frequency comb stabilization...

  6. Absolute parametric instability of low frequency waves in a 2-D nonuniform anisotropic warm plasma

    International Nuclear Information System (INIS)

    Zaki, N.G.

    2004-01-01

    Using the separation method, the problem of absolute parametric instability (API) of electrostatic waves in magnetized pumped warm plasma is investigated. In this case the effect of static strong magnetic field is considered. The problem of strong magnetic field is solved in 2-D nonuniform plane plasma. The equations which describe the spatial part of the electric potential are obtained. Also the growth rates and conditions of the parametric instability for periodic cases are obtained. It is found that the spatial nonuniformity of the plasma exerts a stabilizing effect on the API. It is shown that the growth rates of periodic and aperiodic API in warm plasma are reduced in comparison with a cold plasma case

  7. Absolute ozone densities in a radio-frequency driven atmospheric pressure plasma using two-beam UV-LED absorption spectroscopy and numerical simulations

    Science.gov (United States)

    Wijaikhum, A.; Schröder, D.; Schröter, S.; Gibson, A. R.; Niemi, K.; Friderich, J.; Greb, A.; Schulz-von der Gathen, V.; O'Connell, D.; Gans, T.

    2017-11-01

    The efficient generation of reactive oxygen species (ROS) in cold atmospheric pressure plasma jets (APPJs) is an increasingly important topic, e.g. for the treatment of temperature sensitive biological samples in the field of plasma medicine. A 13.56 MHz radio-frequency (rf) driven APPJ device operated with helium feed gas and small admixtures of oxygen (up to 1%), generating a homogeneous glow-mode plasma at low gas temperatures, was investigated. Absolute densities of ozone, one of the most prominent ROS, were measured across the 11 mm wide discharge channel by means of broadband absorption spectroscopy using the Hartley band centred at λ = 255 nm. A two-beam setup with a reference beam in Mach-Zehnder configuration is employed for improved signal-to-noise ratio allowing high-sensitivity measurements in the investigated single-pass weak-absorbance regime. The results are correlated to gas temperature measurements, deduced from the rotational temperature of the N2 (C 3 {{{\\Pi }}}u+ \\to B 3 {{{\\Pi }}}g+, υ = 0 \\to 2) optical emission from introduced air impurities. The observed opposing trends of both quantities as a function of rf power input and oxygen admixture are analysed and explained in terms of a zero-dimensional plasma-chemical kinetics simulation. It is found that the gas temperature as well as the densities of O and O2(b{}1{{{Σ }}}g+) influence the absolute O3 densities when the rf power is varied.

  8. Frequency of Medically Unexplained Symptoms in Homeopathy References of

    Directory of Open Access Journals (Sweden)

    Yavari M

    2011-06-01

    Full Text Available Background and Objectives: 25-50 percent of all patients who are visited by GPs, have complains that are not medically explained. Their management is a challenge for GPs. In homeopathy (a method of alternative medicine these symptoms are important for selection of remedies and in an effort to treat them. This study aimed at describing this existing situation by investigating the frequency of such complaints in the patients under study.Methods: This study is a cross-sectional study conducted in Isfahan in 2008 on 240 Patients who were visited in some of the clinics affiliated to Isfahan university of medical sciences. The patients were selected by convenient method. Data were gathered by the questionnaire and analyzed via SPSS 13.5 software using Chi-Square test.Results: Out of 240 patients, 150 were women (%65.4 and 90 were men(34.6%. 75.4 percent were 20-40 years old. 1.7 percent had no symptoms, 31.3 had 1-5 symptoms and 40.8 percent had 6-10 symptoms. The females had more symptoms than males. Symptoms of mind, GI, sleep and miscellaneous ones were 81.3, 80.4, 72.1 and 87.1 percent, respectively. The most frequent symptoms in each group were intrusive thought, salivation in sleep, waking frequently and dyspnea wearing tight collared clothes. Only 10.97 percent of patient referred to the physicians for these symptoms.Conclusion: The symptoms registered in homeopathy references have notable prevalence in the society but most of people with such symptoms will not go to a doctor for examination and treatment Therefore, it is very important to carry out more research regarding these symptoms. General population should receive more information and physicians, in turn, should use appropriate methods of therapy for treating these patients.

  9. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Science.gov (United States)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  10. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Directory of Open Access Journals (Sweden)

    Roman Windl

    2017-11-01

    Full Text Available Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  11. Traceable calibration of a horizontally polarised reference antenna with omnidirectional pattern at VHF frequencies for ILS field strength validation

    Science.gov (United States)

    Schrader, T.; Kleine-Ostmann, T.; Bredemeyer, J.

    2013-07-01

    We present a traceable calibration of a specially designed horizontally polarised reference antenna with an omnidirectional pattern in the E-plane for the frequency range between 105 MHz and 120 MHz. This antenna is used as a validation tool for absolute field strength measurements at the localizer transmitter of an instrument landing system (ILS) at airports and is carried by a helicopter. We investigate whether we can treat it as a dipole-like antenna in the calibration setup despite its disk-shape body. We also investigate the suitability of an anechoic chamber for antenna calibration though it was not designed for that purpose. The measurements are based on scattering parameters (S-parameters) which we apply in the 3-antenna-method (TAM or 3-AM) to obtain the antenna gain and the antenna factor, respectively. An uncertainty budget for the antenna gain calibration is derived. We also report on the first practical application of the calibrated reference antenna.

  12. A novel multi-dimensional absolute distance measurement system using a basic frequency modulated continuous wave radar and an external cavity laser with trilateration metrology

    Science.gov (United States)

    Xiong, Xingting; Qu, Xinghua; Zhang, Fumin

    2018-01-01

    We propose and describe a novel multi-dimensional absolute distance measurement system. This system incorporates a basic frequency modulated continuous wave (FMCW) radar and an second external cavity laser (ECL). Through the use of trilateration, the system in our paper can provide 3D resolution inherently range. However, the measured optical path length differences (OPD) is often variable in industrial environments and this will causes Doppler effect, which has greatly impact on the measurement result. With using the second ECL, the system can correct the Doppler effect to ensure the precision of absolute distance measurement. Result of the simulation will prove the influence of Doppler effect.

  13. The frequency of dietary references in homeopathic consultations.

    Science.gov (United States)

    Filho, Rubens Dolce

    2011-07-01

    A retrospective quantitative study on dietary references found in medical records of 2753 patients attending consultations from 10/1/1994 to 5/31/2007 was conducted. The symptoms found in the rubrics relating to food and drink aggravation and amelioration, aversion and craving of homeopathic repertories reflect diets at different places and times and do not correspond fully, to contemporary gastronomy. Desires for sweet and spicy foods were statistically more frequent, revealing the prevailing taste for such food among the studied population. Food cravings should be carefully analyzed before considering them as indications for choosing homeopathic therapy, they are less significant than aversions, aggravations and ameliorations. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Analysis and compensation of reference frequency mismatch in multiple-frequency feedforward active noise and vibration control system

    Science.gov (United States)

    Liu, Jinxin; Chen, Xuefeng; Yang, Liangdong; Gao, Jiawei; Zhang, Xingwu

    2017-11-01

    In the field of active noise and vibration control (ANVC), a considerable part of unwelcome noise and vibration is resulted from rotational machines, making the spectrum of response signal multiple-frequency. Narrowband filtered-x least mean square (NFXLMS) is a very popular algorithm to suppress such noise and vibration. It has good performance since a priori-knowledge of fundamental frequency of the noise source (called reference frequency) is adopted. However, if the priori-knowledge is inaccurate, the control performance will be dramatically degraded. This phenomenon is called reference frequency mismatch (RFM). In this paper, a novel narrowband ANVC algorithm with orthogonal pair-wise reference frequency regulator is proposed to compensate for the RFM problem. Firstly, the RFM phenomenon in traditional NFXLMS is closely investigated both analytically and numerically. The results show that RFM changes the parameter estimation problem of the adaptive controller into a parameter tracking problem. Then, adaptive sinusoidal oscillators with output rectification are introduced as the reference frequency regulator to compensate for the RFM problem. The simulation results show that the proposed algorithm can dramatically suppress the multiple-frequency noise and vibration with an improved convergence rate whether or not there is RFM. Finally, case studies using experimental data are conducted under the conditions of none, small and large RFM. The shaft radial run-out signal of a rotor test-platform is applied to simulate the primary noise, and an IIR model identified from a real steel structure is applied to simulate the secondary path. The results further verify the robustness and effectiveness of the proposed algorithm.

  15. Reference intervals for absolute and percentage immature platelet fraction using the Sysmex XN-10 automated haematology analyser in a UK population.

    Science.gov (United States)

    Ali, Usman; Knight, Gavin; Gibbs, Roz; Tsitsikas, Dimitris A

    2017-12-01

    Immature platelet fraction (IPF) estimation is a non-invasive and sensitive test that is available on recently introduced Sysmex XN-series of automated haematology analysers. It is a direct cellular indicator of thrombopoiesis. The aim of this study was to establish reference intervals for IPF, for both absolute (A-IPF) and percentage (%-IPF) measurements. A total of 2366 samples that met the inclusion criteria were assayed for full blood count on the Sysmex XN-10 and a non-parametric percentile method was used for calculating the reference intervals. After the outliers were excluded, the reference interval for %-IPF and A-IPF on Sysmex XN-10 were 1.6-10.1% and 4.37-23.21 × 10 9 /L in total individuals, respectively. There was a statistical significance noted between the sexes (p = .004) for %-IPF, therefore a sex-specific reference interval was established, which was 1.8-10.0% for the males and 1.5-10.1% for females. No significant difference in sex status for A-IPF and age status for both %-IPF and A-IPF was observed. A very poor correlation was estimated between age versus %-IPF, ρ = 0.0156, and age versus A-IPF, ρ = -0.0023, indicating that there is no overall biological relationship between age and these parameters. As expected, a strong correlation between %-IPF and A-IPF was noted which could be attributed to their inter-relatedness. This large-scale study showed comparable reference intervals with the previous studies for %-IPF and A-IPF in a UK population. It found the need to establish sex-specific reference intervals for %-IPF, but not for A-IPF, whereas reference intervals were found to be stable across the age range.

  16. A 2015 International Geomagnetic Reference Field (IGRF) candidate model based on Swarm’s experimental absolute magnetometer vector mode data

    DEFF Research Database (Denmark)

    Vigneron, Pierre; Hulot, Gauthier; Olsen, Nils

    2015-01-01

    to epoch 2015.0 and truncated at degree and order 13. The resulting ASM-only 2015.0 IGRF candidate model is compared to analogous models derived from the mission’s nominal data and to the now-published final 2015.0 IGRF model. Differences among models mainly highlight uncertainties enhanced by the limited...... data. Here, we report on how ASM-only scalar and vector data from the Alpha and Bravo satellites between November 29, 2013 (a week after launch) and September 25, 2014 (for on-time delivery of the model on October 1, 2014) could be used to build a very valuable candidate model for the 2015.......0 International Geomagnetic Reference Field (IGRF). A parent model was first computed, describing the geomagnetic field of internal origin up to degree and order 40 in a spherical harmonic representation and including a constant secular variation up to degree and order 8. This model was next simply forwarded...

  17. Reference absolute and indexed values for left and right ventricular volume, function and mass from cardiac computed tomography

    International Nuclear Information System (INIS)

    Stojanovska, Jadranka; Prasitdumrong, Hutsaya; Patel, Smita; Sundaram, Baskaran; Gross, Barry H.; Yilmaz, Zeynep N.; Kazerooni, Ella A.

    2014-01-01

    Left ventricular (LV) and right ventricular (RV) volumetric and functional parameters are important biomarkers for morbidity and mortality in patients with heart failure. To retrospectively determine reference mean values of LV and RV volume, function and mass normalised by age, gender and body surface area (BSA) from retrospectively electrocardiographically gated 64-slice cardiac computed tomography (CCT) by using automated analysis software in healthy adults. The study was approved by the institutional review board with a waiver of informed consent. Seventy-four healthy subjects (49% female, mean age 49.6±11) free of hypertension and hypercholesterolaemia with a normal CCT formed the study population. Analyses of LV and RV volume (end-diastolic, end-systolic and stroke volumes), function (ejection fraction), LV mass and inter-rater reproducibility were performed with commercially available analysis software capable of automated contour detection. General linear model analysis was performed to assess statistical significance by age group after adjustment for gender and BSA. Bland–Altman analysis assessed the inter-rater agreement. The reference range for LV and RV volume, function, and LV mass was normalised to age, gender and BSA. Statistically significant differences were noted between genders in both LV mass and RV volume (P-value<0.0001). Age, in concert with gender, was associated with significant differences in RV end-diastolic volume and LV ejection fraction (P-values 0.027 and 0.03). Bland–Altman analysis showed acceptable limits of agreement (±1.5% for ejection fraction) without systematic error. LV and RV volume, function and mass normalised to age, gender and BSA can be reported from CCT datasets, providing additional information important for patient management.

  18. Performance of transmit-reference radio system in frequency-selective fading channels

    NARCIS (Netherlands)

    Wang, Jing; Haartsen, J.C.

    2005-01-01

    Noise-based Transmit-Reference (TR) radio system is a simple and practical candidate for ultra-wideband (UWB) communication applications. This paper evaluates the performance of the Transmit-Reference radio system in a frequency-selective fading channel by theoretical analysis and computer

  19. Frequency-comb-assisted absolute calibration and linestrength of H12C13CH ro-vibrational transitions in the 2ν3 band

    Science.gov (United States)

    Di Sarno, Valentina; De Natale, Paolo; Tasseva, Jordanka; Santamaria, Luigi; Cané, Elisabetta; Tamassia, Filippo; Maddaloni, Pasquale

    2018-02-01

    We report on a precision spectroscopic study of room-temperature H12C13CH in the 6463-6520 cm-1 range, using a continuous-wave diode laser phase-locked to a near-infrared optical frequency comb synthesizer stabilized, in turn, against a GPS-disciplined rubidium clock. By tuning the comb repetition frequency, several ro-vibrational transitions in the P and R branches of the 2ν3 overtone band are recorded. Accuracy levels as low as 100 kHz, 5 ·10-10 in fractional terms, are obtained in the determination of absolute line-center frequencies. In addition, line intensities are measured for the first time, with a best fractional uncertainty of 1%, and used to retrieve the purely vibrational transition dipole moment in conjunction with the first-order Herman-Wallis factor. Finally, the pressure broadening coefficients γself are also derived for the studied transitions.

  20. Relative frequency and estimated minimal frequency of Lysosomal Storage Diseases in Brazil: Report from a Reference Laboratory

    Directory of Open Access Journals (Sweden)

    Roberto Giugliani

    2017-03-01

    Full Text Available Abstract Lysosomal storage diseases (LSDs comprise a heterogeneous group of more than 50 genetic conditions of inborn errors of metabolism (IEM caused by a defect in lysosomal function. Although there are screening tests for some of these conditions, diagnosis usually depends on specific enzyme assays, which are only available in a few laboratories around the world. A pioneer facility for the diagnosis of IEM and LSDs was established in the South of Brazil in 1982 and has served as a reference service since then. Over the past 34 years, samples from 72,797 patients were referred for investigation of IEM, and 3,211 were confirmed as having an LSD (4.41%, or 1 in 22, with 3,099 of these patients originating from Brazil. The rate of diagnosis has increased over time, in part due to the creation of diagnostic networks involving a large number of Brazilian services. These cases, referred from Brazilian regions, provide insight about the relative frequency of LSDs in the country. The large amount of data available allows for the estimation of the minimal frequency of specific LSDs in Brazil. The reported data could help to plan health care policies, as there are specific therapies available for most of the cases diagnosed.

  1. Flight-Like Optical Reference Cavity for GRACE Follow-On Laser Frequency Stabilization

    Science.gov (United States)

    Folkner, W. M.; deVine, G.; Klipstein, W. M.; McKenzie, K.; Spero, R.; Thompson, R.; Yu, N.; Stephens, M.; Leitch, J.; Pierce, R.; hide

    2011-01-01

    We describe a prototype optical cavity and associated optics that has been developed to provide a stable frequency reference for a future space-based laser ranging system. This instrument is being considered for inclusion as a technology demonstration on the recently announced GRACE follow-on mission, which will monitor variations in the Earth's gravity field.

  2. Control of the repeatability of high frequency multibeam echosounder backscatter by using natural reference areas

    Science.gov (United States)

    Roche, Marc; Degrendele, Koen; Vrignaud, Christophe; Loyer, Sophie; Le Bas, Tim; Augustin, Jean-Marie; Lurton, Xavier

    2018-01-01

    The increased use of backscatter measurements in time series for environmental monitoring necessitates the comparability of individual results. With the current lack of pre-calibrated multibeam echosounder systems for absolute backscatter measurement, a pragmatic solution is the use of natural reference areas for ensuring regular assessment of the backscatter measurement repeatability. This method mainly relies on the assumption of a sufficiently stable reference area regarding its backscatter signature. The aptitude of a natural area to provide a stable and uniform backscatter response must be carefully considered and demonstrated by a sufficiently long time-series of measurements. Furthermore, this approach requires a strict control of the acquisition and processing parameters. If all these conditions are met, stability check and relative calibration of a system are possible by comparison with the averaged backscatter values for the area. Based on a common multibeam echosounder and sampling campaign completed by available bathymetric and backscatter time series, the suitability as a backscatter reference area of three different candidates was evaluated. Two among them, Carré Renard and Kwinte, prove to be excellent choices, while the third one, Western Solent, lacks sufficient data over time, but remains a valuable candidate. The case studies and the available backscatter data on these areas prove the applicability of this method. The expansion of the number of commonly used reference areas and the growth of the number of multibeam echosounder controlled thereon could greatly contribute to the further development of quantitative applications based on multibeam echosounder backscatter measurements.

  3. The relative and absolute frequencies of angiosperm sexual systems: dioecy, monoecy, gynodioecy, and an updated online database.

    Science.gov (United States)

    Renner, Susanne S

    2014-10-01

    • Separating sexual function between different individuals carries risks, especially for sedentary organisms. Nevertheless, many land plants have unisexual gametophytes or sporophytes. This study brings together data and theoretical insights from research over the past 20 yr on the occurrence and frequency of plant sexual systems, focusing on the flowering plants.• A list of genera with dioecious species, along with other information, is made available (http://www.umsl.edu/∼renners/). Frequencies of other sexual systems are tabulated, and data on the genetic regulation, ecological context, and theoretical benefits of dioecy reviewed.• There are 15600 dioecious angiosperms in 987 genera and 175 families, or 5-6% of the total species (7% of genera, 43% of families), with somewhere between 871 to 5000 independent origins of dioecy. Some 43% of all dioecious angiosperms are in just 34 entirely dioecious clades, arguing against a consistent negative influence of dioecy on diversification. About 31.6% of the dioecious species are wind-pollinated, compared with 5.5-6.4% of nondioecious angiosperms. Also, 1.4% of all angiosperm genera contain dioecious and monoecious species, while 0.4% contain dioecious and gynodioecious species. All remaining angiosperm sexual systems are rare. Chromosomal sex determination is known from 40 species; environmentally modulated sex allocation is common. Few phylogenetic studies have focused on the evolution of dioecy.• The current focus is on the genetic mechanisms underlying unisexual flowers and individuals. Mixed strategies of sexual and vegetative dispersal, together with plants' sedentary life style, may often favor polygamous systems in which sexually inconstant individuals can persist. Nevertheless, there are huge entirely dioecious clades of tropical woody plants. © 2014 Botanical Society of America, Inc.

  4. How calibration and reference spectra affect the accuracy of absolute soft X-ray solar irradiance measured by the SDO/EVE/ESP during high solar activity

    Science.gov (United States)

    Didkovsky, Leonid; Wieman, Seth; Woods, Thomas

    2016-10-01

    The Extreme ultraviolet Spectrophotometer (ESP), one of the channels of SDO's Extreme ultraviolet Variability Experiment (EVE), measures solar irradiance in several EUV and soft x-ray (SXR) bands isolated using thin-film filters and a transmission diffraction grating, and includes a quad-diode detector positioned at the grating zeroth-order to observe in a wavelength band from about 0.1 to 7.0 nm. The quad diode signal also includes some contribution from shorter wavelength in the grating's first-order and the ratio of zeroth-order to first-order signal depends on both source geometry, and spectral distribution. For example, radiometric calibration of the ESP zeroth-order at the NIST SURF BL-2 with a near-parallel beam provides a different zeroth-to-first-order ratio than modeled for solar observations. The relative influence of "uncalibrated" first-order irradiance during solar observations is a function of the solar spectral irradiance and the locations of large Active Regions or solar flares. We discuss how the "uncalibrated" first-order "solar" component and the use of variable solar reference spectra affect determination of absolute SXR irradiance which currently may be significantly overestimated during high solar activity.

  5. Towards absolute quantification of allergenic proteins in food--lysozyme in wine as a model system for metrologically traceable mass spectrometric methods and certified reference materials.

    Science.gov (United States)

    Cryar, Adam; Pritchard, Caroline; Burkitt, William; Walker, Michael; O'Connor, Gavin; Burns, Duncan Thorburn; Quaglia, Milena

    2013-01-01

    Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.

  6. Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

    International Nuclear Information System (INIS)

    Niemi, K.; O'Connell, D.; Gans, T.; Oliveira, N. de; Joyeux, D.; Nahon, L.; Booth, J. P.

    2013-01-01

    Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N 2 /O 2 (4:1) admixtures. A maximum in the O-atom concentration of (9.1 ± 0.7)×10 20 m −3 was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 ± 0.4)×10 19 m −3 at 0.1 vol. %

  7. High frequency dielectric reference materials BCR projekt 43. Final report of phase 1

    International Nuclear Information System (INIS)

    Chantry, G.

    1980-01-01

    The Group of High Frequency Specialists from Belgium, France, Germany, The Netherlands and the UK, was awarded contracts in 1975 to carry out a programme of measurements on the high frequency dielectric properties of materials. The object of this first phase of a projected three phase programme was to establish the reliability of existing methods of measurement and to examine the possibilities of specifying and producing some standard reference materials, both liquid and solid, which could be used for calibrating and checking the performance of industrial measurement equipment. The liquids chosen for the first phase were cyclohexane, cis and trans decalin, chlorobenzene and 0.1, 1, and 10% solutions of chlorobenzene in cyclohexane. Each group had a limited frequency range over which it could make meaningful measurements but there was sufficient overlap to ensure that all random and systematic errors could be quantitatively assayed. The real (epsilon') and imaginary (epsilon'') components of the complex permittivity for all the liquids were measured over the frequency range 10 - 3,000 GHz and for the two most lossy liquids (chlorobenzene and 10% chlorobenzene in cyclohexane) this range was extended downwards to one GHz. The programme established for the first time the possible experimental imprecisions to be expected in high frequency dielecric measurements and showed that the chosen liquids could be useful standard reference materials if sufficiently pure specimens could be obtained commercially at a reasonable price. The programme did however reveal an unexpected snag in that the liquids, especially cyclohexane, were found to be rather more liable to contamination than expected. Since cyclohexane is a very low-loss liquid, only a small amount of a lossy contaminant need be absorbed to make the observed loss increase dramatically. This report contains all the measured results in both tabular and graphical form and in addition full technical details are given of the

  8. Frequency-stabilised laser reference system for trace-gas sensing applications from space

    Science.gov (United States)

    Matthey, Renaud; Affolderbach, Christoph; Mileti, Gaetano; Schilt, Stéphane; Werner, Daniela; Chin, Sanghoon; Abrardi, Laura; Thévenaz, Luc

    2017-11-01

    A four-wavelength low-power continuous-wave frequency laser reference system has been realised in the 935.4-nm range for water vapour differential absorption lidar (DIAL) applications. The system is built around laboratory extended-cavity and DFB diode lasers. Three lasers are directly locked to three water vapour absorption lines of different strength, whereas the wavelength of the fourth laser lies out of any absorption line (offline). On-line stabilisation is performed by wavelength modulation spectroscopy technique, while precise offline stabilisation is realised by an offset locking at 18.8 GHz. Offset frequency larger than 320 GHz has also been demonstrated at 1.55 μm, based on an all-fibre optical frequency comb. First steps towards the use of a photonic crystal fibre as ultra compact reference cell with long optical pathlength were realised. The developed techniques for direct and offset-lock laser stabilisation can also be applied to other gases and wavelengths, provided the required optical components are available for the laser wavelength considered.

  9. Exploiting elastic anharmonicity in aluminum nitride matrix for phase-synchronous frequency reference generation

    Science.gov (United States)

    Ghatge, Mayur; Tabrizian, Roozbeh

    2018-03-01

    A matrix of aluminum-nitride (AlN) waveguides is acoustically engineered to realize electrically isolated phase-synchronous frequency references through nonlinear wave-mixing. AlN rectangular waveguides are cross-coupled through a periodically perforated plate that is engineered to have a wide acoustic bandgap around a desirable frequency ( f1≈509 MHz). While the coupling plate isolates the matrix from resonant vibrations of individual waveguide constituents at f1, it is transparent to the third-order harmonic waves (3f1) that are generated through nonlinear wave-mixing. Therefore, large-signal excitation of the f1 mode in a constituent waveguide generates acoustic waves at 3f1 with an efficiency defined by elastic anharmonicity of the AlN film. The phase-synchronous propagation of the third harmonic through the matrix is amplified by a high quality-factor resonance mode at f2≈1529 MHz, which is sufficiently close to 3f1 (f2 ≅ 3f1). Such an architecture enables realization of frequency-multiplied and phase-synchronous, yet electrically and spectrally isolated, references for multi-band/carrier and spread-spectrum wireless communication systems.

  10. Absolute MR thermometry using nanocarriers.

    Science.gov (United States)

    Deckers, Roel; Sprinkhuizen, Sara M; Crielaard, Bart J; Ippel, Johannes H; Boelens, Rolf; Bakker, Chris J G; Storm, Gert; Lammers, Twan; Bartels, Lambertus W

    2014-01-01

    Accurate time-resolved temperature mapping is crucial for the safe use of hyperthermia-mediated drug delivery. We here propose a magnetic resonance imaging temperature mapping method in which drug delivery systems serve not only to improve tumor targeting, but also as an accurate and absolute nano-thermometer. This method is based on the temperature-dependent chemical shift difference between water protons and the protons in different groups of drug delivery systems. We show that the chemical shift of the protons in the ethylene oxide group in polyethylene glycol (PEG) is temperature-independent, whereas the proton resonance of water decreases with increasing temperature. The frequency difference between both resonances is linear and does not depend on pH and physiological salt conditions. In addition, we show that the proton resonance of the methyl group in N-(2-hydroxypropyl)-methacrylamide (HPMA) is temperature-independent. Therefore, PEGylated liposomes, polymeric mPEG-b-pHPMAm-Lac2 micelles and HPMA copolymers can provide a temperature-independent reference frequency for absolute magnetic resonance (MR) thermometry. Subsequently, we show that multigradient echo MR imaging with PEGylated liposomes in situ allows accurate, time-resolved temperature mapping. In conclusion, nanocarrier materials may serve as highly versatile tools for tumor-targeted drug delivery, acting not only as hyperthermia-responsive drug delivery systems, but also as accurate and precise nano-thermometers. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Mode-locked semiconductor laser for long and absolute distance measurement based on laser pulse repetition frequency sweeping: a comparative study between three types of lasers

    Science.gov (United States)

    Castro Alves, D.; Abreu, Manuel; Cabral, Alexandre; Rebordão, J. M.

    2017-08-01

    In this work we present a study on three types of semiconductor mode-locked lasers as possible sources for a high precision absolute distance metrology measurement concept based on pulse repetition frequency (PRF) sweep. In this work, we evaluated one vertical emission laser and two transversal emission sources. The topology of the gain element is quantum-well, quantum-dot and quantum-dash, respectively. Only the vertical emission laser has optical pump, whilst the others operate with electric pumping. The quantum-dash laser does not have a saturable absorber in its configuration but relies on a dispersion compensating fiber for generating pulses. The bottleneck of vertical emission laser is his high power density pump (4.5W/165μm), increasing the vulnerability of damaging the gain element. The other lasers, i.e., the single (quantum-dash) and double section (quantum-dot) lasers present good results either in terms of applicability to the metrology system or in terms of robustness. Using RF injection on the gain element, both lasers show good PRF stabilization results (better than σy(10ms) = 10-9 ) which is a requirement for the mentioned metrology technique.

  12. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  13. Frequency stabilization of a 2.05 μm laser using hollow-core fiber CO2 frequency reference cell

    Science.gov (United States)

    Meras, Patrick; Poberezhskiy, Ilya Y.; Chang, Daniel H.; Spiers, Gary D.

    2010-04-01

    We have designed and built a hollow-core fiber frequency reference cell, filled it with CO2, and used it to demonstrate frequency stabilization of a 2.05 μm Tm:Ho:YLF laser using frequency modulation (FM) spectroscopy technique. The frequency reference cell is housed in a compact and robust hermetic package that contains a several meter long hollow-core photonic crystal fiber optically coupled to index-guiding fibers with a fusion splice on one end and a mechanical splice on the other end. The package has connectorized fiber pigtails and a valve used to evacuate, refill it, or adjust the gas pressure. We have demonstrated laser frequency standard deviation decreasing from >450MHz (free-running) to laser wavelength is of particular interest for spectroscopic instruments due to the presence of many CO2 and H20 absorption lines in its vicinity. To our knowledge, this is the first reported demonstration of laser frequency stabilization at this wavelength using a hollow-core fiber reference cell. This approach enables all-fiber implementation of the optical portion of laser frequency stabilization system, thus making it dramatically more lightweight, compact, and robust than the traditional free-space version that utilizes glass or metal gas cells. It can also provide much longer interaction length of light with gas and does not require any alignment. The demonstrated frequency reference cell is particularly attractive for use in aircraft and space coherent lidar instruments for measuring atmospheric CO2 profile.

  14. 3C-Silicon Carbide Microresonators for Timing and Frequency Reference

    Directory of Open Access Journals (Sweden)

    Graham S. Wood

    2016-11-01

    Full Text Available In the drive to miniaturise and integrate reference oscillator components, microelectromechanical systems (MEMS resonators are excellent candidates to replace quartz crystals. Silicon is the most utilised resonator structural material due to its associated well-established fabrication processes. However, when operation in harsh environments is required, cubic silicon carbide (3C-SiC is an excellent candidate for use as a structural material, due to its robustness, chemical inertness and high temperature stability. In order to actuate 3C-SiC resonators, electrostatic, electrothermal and piezoelectric methods have been explored. Both electrothermal and piezoelectric actuation can be accomplished with simpler fabrication and lower driving voltages, down to 0.5 V, compared to electrostatic actuation. The vibration amplitude at resonance can be maximised by optimising the design and location of the electrodes. Electrical read out of the resonator can be performed with electrostatic or piezoelectric transduction. Finally, a great deal of research has focused on tuning the resonant frequency of a 3C-SiC resonator by adjusting the DC bias applied to the electrodes, with a higher (up to 160-times tuning range for electrothermal tuning compared to piezoelectric tuning. Electrothermal tuning lowers the frequency, while piezoelectric tuning can be used to raise the frequency.

  15. Measurement of absolute concentrations of individual compounds in metabolite mixtures by gradient-selective time-zero 1H-13C HSQC with two concentration references and fast maximum likelihood reconstruction analysis.

    Science.gov (United States)

    Hu, Kaifeng; Ellinger, James J; Chylla, Roger A; Markley, John L

    2011-12-15

    Time-zero 2D (13)C HSQC (HSQC(0)) spectroscopy offers advantages over traditional 2D NMR for quantitative analysis of solutions containing a mixture of compounds because the signal intensities are directly proportional to the concentrations of the constituents. The HSQC(0) spectrum is derived from a series of spectra collected with increasing repetition times within the basic HSQC block by extrapolating the repetition time to zero. Here we present an alternative approach to data collection, gradient-selective time-zero (1)H-(13)C HSQC(0) in combination with fast maximum likelihood reconstruction (FMLR) data analysis and the use of two concentration references for absolute concentration determination. Gradient-selective data acquisition results in cleaner spectra, and NMR data can be acquired in both constant-time and non-constant-time mode. Semiautomatic data analysis is supported by the FMLR approach, which is used to deconvolute the spectra and extract peak volumes. The peak volumes obtained from this analysis are converted to absolute concentrations by reference to the peak volumes of two internal reference compounds of known concentration: DSS (4,4-dimethyl-4-silapentane-1-sulfonic acid) at the low concentration limit (which also serves as chemical shift reference) and MES (2-(N-morpholino)ethanesulfonic acid) at the high concentration limit. The linear relationship between peak volumes and concentration is better defined with two references than with one, and the measured absolute concentrations of individual compounds in the mixture are more accurate. We compare results from semiautomated gsHSQC(0) with those obtained by the original manual phase-cycled HSQC(0) approach. The new approach is suitable for automatic metabolite profiling by simultaneous quantification of multiple metabolites in a complex mixture.

  16. Measurement of Absolute Concentrations of Individual Compounds in Metabolite Mixtures by Gradient-Selective Time-Zero 1H-13C HSQC (gsHSQC0) with Two Concentration References and Fast Maximum Likelihood Reconstruction Analysis

    Science.gov (United States)

    Hu, Kaifeng; Ellinger, James J.; Chylla, Roger A.; Markley, John L.

    2011-01-01

    Time-zero 2D 13C HSQC (HSQC0) spectroscopy offers advantages over traditional 2D NMR for quantitative analysis of solutions containing a mixture of compounds because the signal intensities are directly proportional to the concentrations of the constituents. The HSQC0 spectrum is derived from a series of spectra collected with increasing repetition times within the basic HSQC block by extrapolating the repetition time to zero. Here we present an alternative approach to data collection, gradient-selective time-zero 1H-13C HSQC0 in combination with fast maximum likelihood reconstruction (FMLR) data analysis and the use of two concentration references for absolute concentration determination. Gradient-selective data acquisition results in cleaner spectra, and NMR data can be acquired in both constant-time and non-constant time mode. Semi-automatic data analysis is supported by the FMLR approach, which is used to deconvolute the spectra and extract peak volumes. The peak volumes obtained from this analysis are converted to absolute concentrations by reference to the peak volumes of two internal reference compounds of known concentration: DSS (4,4-dimethyl-4-silapentane-1-sulfonic acid) at the low concentration limit (which also serves as chemical shift reference) and MES (2-(N-morpholino)ethanesulfonic acid) at the high concentration limit. The linear relationship between peak volumes and concentration is better defined with two references than with one, and the measured absolute concentrations of individual compounds in the mixture are more accurate. We compare results from semi-automated gsHSQC0 with those obtained by the original manual phase-cycled HSQC0 approach. The new approach is suitable for automatic metabolite profiling by simultaneous quantification of multiple metabolites in a complex mixture. PMID:22029275

  17. Changes in the frequency of food intake among children and teenagers: monitoring in a reference service

    Directory of Open Access Journals (Sweden)

    Larissa Soares Mariz

    2013-07-01

    Full Text Available PURPOSE: to identify changes in the food intake patterns among overweight children and teenagers, treated at a reference medical centre. METHOD: the method used is that of a cohort study, between April 2010 and April 2011. A total of 109 children and teenagers, either obese or overweight, took part in the study. The population was divided into two subgroups depending on the permanence period (more than 6 months, and less than 6 months off the treatment. The chi-square test and logistic regression were carried out. RESULTS: the group which had been longer off the treatment tended to consume more soft drinks, pasta and fried foods, and less fruit and vegetables. The group with less time showed an improvement, with a reduction of consumption of soft drinks and other goodies. There was confirmation of an increased risk for consumption of soft drinks, pasta and goodies in general, as also detachment from the treatment in adolescence. CONCLUSIONS: The group with a longer period of monitoring has had a positive change in food intake frequency. The main contribution made by this study is that of showing that multiprofissional treatment, including some nursing care, is efficient in progressively changing the food intake of children and adolescents who are overweight.

  18. An improved synchronous reference frame phase-locked loop for stand-alone variable speed constant frequency power generation systems

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Ke, Longzhang

    2017-01-01

    The phase-locked loop (PLL) based on conventional synchronous reference frame, i.e. dqPLL, is usually employed in grid-connected variable speed constant frequency (VSCF) power generation systems (PGSs). However, the voltage amplitude drop of stand-alone PGSs is often greater than that of the grid...

  19. Frequency and Informativeness of Gestural Cues Accompanying Generic and Particular Reference

    Science.gov (United States)

    Meyer, Meredith; Gelman, Susan A.; Stilwell, Sarah M.

    2015-01-01

    Generic noun phrases, or generics, refer to abstract categories ("Dogs" bark) rather than particular individuals ("Those dogs" bark). Study 1 investigated how parents use gestures in association with generic versus particular reference during naturalistic interactions with their 2- and 3-year-old children. Parents provided…

  20. High-precision, accurate optical frequency reference using a Fabry-Perót diode laser

    Science.gov (United States)

    Chang, Hongrok; Myneni, Krishna; Smith, David D.; Liaghati-Mobarhan, Hassan R.

    2017-06-01

    We show that the optical output of a temperature and current-tuned Fabry-Perót diode laser system, with no external optical feedback and in which the frequency is locked to Doppler-free hyperfine resonances of the 87Rb D2 line, can achieve high frequency stability and accuracy. Experimental results are presented for the spectral linewidth, frequency stability, and frequency accuracy of the source. Although our optical source is limited by a short-term spectral linewidth greater than 2 MHz, beat signal measurements from two such sources demonstrate a frequency stability of 1.1 kHz, or minimum Allan deviation of 4 ×1 0-12, at an integration time τ =15 s and with a frequency accuracy of 60 kHz at τ =300 s. We demonstrate the use of the optical source for the precision measurement of hyperfine level frequency spacings in the 5 P3 /2 excited state of 87Rb and provide an accurate frequency scale for optical spectroscopy.

  1. Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications

    Science.gov (United States)

    Burt, Eric A. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor); Larsen, Kameron (Inventor); Tjoelker, Robert L. (Inventor)

    2017-01-01

    An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.

  2. Frequency and molecular diagnosis of trichomoniasis in symptomatic women referred to laboratories in urmia north west Iran

    Directory of Open Access Journals (Sweden)

    Elham Shahnazi

    2017-07-01

    Full Text Available Objective: To obtain the frequency of trichomoniasis and molecular diagnosis among women referred to a laboratory in Urmia (north west Iran. Methods: In the cross sectional study during the year 2014-2015, women with complaints of abnormal discharge, itching, irritation and unpleasant odor were studied using convenience sampling. These people were referred to one of the laboratories in city by gynecologist. After preparing the checklist of underlying data, vaginal wet smear samples was prepared to direct microscopy and molecular assess. Results were analyzed with statistical tests. Results: Totally 39.2% of referred cases were 30-40 years old, and about 54.8% of referred were illiterate and primitive. The frequency of trichomoniasis was 11.1% and statistically there was no significant difference. There was no significant difference among the age, education level, method of contraception, marriage age, location, employment status and the number of delivery with T. vaginalis. Conclusion: T. vaginalis compared to other studies have a moderate frequency among women of Urmia. Because of the concordance of this infection with other sexual transmitted diseases, it is recommended further studies about the prevalence of trichomoniasis in Urmia.

  3. The manufacture and analysis of a reference defect for high frequency ultrasonic inspections of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Graf, M.A.

    1990-01-01

    Ultrasonic inspection has long been used to monitor CANDU reactor pressure tubes both during their manufacture and in service. Conventional 10 MHz inspection techniques have missed some inclusion-type defects, which were later discovered using high-frequency (100 MHz) techniques. The routine use of high-frequency techniques is being considered. A reference defect is needed to demonstrate the effectiveness and accuracy of this technique. A reference defect was manufactured by inserting small metallic inclusions along the radial centre line of a pressure tube wall. Two equal-length sections of tube were cut and machined so the inner diameter of one was equal to the outer diameter of the other. Sample defects in the form of thin shims and wires were placed on the outer surface of the smaller tube. The larger tube was fitted around it. The tubes were bonded together using the HIP (hot isostatic press) process. All of the defects were detectable at 10 MHz, and therefore the reference defect was not suitable to evaluate high-frequency techniques. Defects at least an order of magnitude smaller should be used. Cylindrical defects tend to be preferable to layered geometries from the point of view of their transparency to lower frequency signals. (L.L.) (3 refs., 4 figs.)

  4. Basic Restriction and Reference Level in Anatomically-based Japanese Models for Low-Frequency Electric and Magnetic Field Exposures

    Science.gov (United States)

    Takano, Yukinori; Hirata, Akimasa; Fujiwara, Osamu

    Human exposed to electric and/or magnetic fields at low frequencies may cause direct effect such as nerve stimulation and excitation. Therefore, basic restriction is regulated in terms of induced current density in the ICNIRP guidelines and in-situ electric field in the IEEE standard. External electric or magnetic field which does not produce induced quantities exceeding the basic restriction is used as a reference level. The relationship between the basic restriction and reference level for low-frequency electric and magnetic fields has been investigated using European anatomic models, while limited for Japanese model, especially for electric field exposures. In addition, that relationship has not well been discussed. In the present study, we calculated the induced quantities in anatomic Japanese male and female models exposed to electric and magnetic fields at reference level. A quasi static finite-difference time-domain (FDTD) method was applied to analyze this problem. As a result, spatially averaged induced current density was found to be more sensitive to averaging algorithms than that of in-situ electric field. For electric and magnetic field exposure at the ICNIRP reference level, the maximum values of the induced current density for different averaging algorithm were smaller than the basic restriction for most cases. For exposures at the reference level in the IEEE standard, the maximum electric fields in the brain were larger than the basic restriction in the brain while smaller for the spinal cord and heart.

  5. [Reference value for micronucleus frequency of peripheral blood lymphocytes in general Chinese population: a method of Monte Carlo simulation].

    Science.gov (United States)

    Teng, Jingjing; Duan, Huawei; Zheng, Yuxin

    2015-12-01

    To estimate the reference value for micronucleus frequency of peripheral blood lymphocytes in general Chinese population, and to guide the genotoxicity evaluation and risk analysis for populations exposed to environmental or occupational chemicals. A fulltext search was performed in CNKI with the key words of "micronucleus" and "human", and PubMed was searched with "cytokinesis-block micronucleus","CBMN","humans", and "adults", to obtain the articles published at home and abroad from 2001 to 2014 in which cytokinesis-block micronucleus (CBMN)assay was applied for micronucleus detection and populations not exposed to genotoxins were established as a control. Monte Carlo simulation was performed based on the micronucleus frequency, standard deviation, and sample size provided in these articles to calculate the micronucleus frequency for general population and to analyze the influence of sex, smoking, and drinking on micronucleus frequency. A total of 23 articles were included in the final analysis. The minimum mean micronucleus frequency was 0.39‰, and the maximum mean micronucleus frequency was 25.3‰. There were 1623 subjects in the control group in total (range 22~178, mean 70.6). Monte Carlo simulation was performed 100 times, and the mode of micronucleus frequency was 0 or 1‰; the values of P0, P25, P50 , P75, and P95 were 0‰, 1‰, 2‰~3‰, 5‰~6‰, and 14‰~19‰, respectively; the mean value was 4.36‰(range 4.22‰~4.57‰). With the application of one-sided 95% range(x±1.64 s), the upper limit of the range of reference value was calculated to be 13.46‰~14.75‰. The micronucleus frequency of peripheral blood lymphocytes in general Chinese population is 4.36‰, the interquartile range is 1‰~5‰ or 1‰~6‰, and the upper limit of reference value is 14.17‰. The factors of living area, sex, smoking, and drinking may influence micronucleus frequency.

  6. Reference-free quantification of EEG spectra: combining current source density (CSD) and frequency principal components analysis (fPCA).

    Science.gov (United States)

    Tenke, Craig E; Kayser, Jürgen

    2005-12-01

    Definition of appropriate frequency bands and choice of recording reference limit the interpretability of quantitative EEG, which may be further compromised by distorted topographies or inverted hemispheric asymmetries when employing conventional (non-linear) power spectra. In contrast, fPCA factors conform to the spectral structure of empirical data, and a surface Laplacian (2-dimensional CSD) simplifies topographies by minimizing volume-conducted activity. Conciseness and interpretability of EEG and CSD fPCA solutions were compared for three common scaling methods. Resting EEG and CSD (30 channels, nose reference, eyes open/closed) from 51 healthy and 93 clinically-depressed adults were simplified as power, log power, and amplitude spectra, and summarized using unrestricted, Varimax-rotated, covariance-based fPCA. Multiple alpha factors were separable from artifact and reproducible across subgroups. Power spectra produced numerous, sharply-defined factors emphasizing low frequencies. Log power spectra produced fewer, broader factors emphasizing high frequencies. Solutions for amplitude spectra showed optimal intermediate tuning, particularly when derived from CSD rather than EEG spectra. These solutions were topographically distinct, detecting multiple posterior alpha generators but excluding the dorsal surface of the frontal lobes. Instead a low alpha/theta factor showed a secondary topography along the frontal midline. CSD amplitude spectrum fPCA solutions provide simpler, reference-independent measures that more directly reflect neuronal activity. A new quantitative EEG approach affording spectral components is developed that closely parallels the concept of an ERP component in the temporal domain.

  7. Mineral concentrations in hair of Belgian elementary school girls: reference values and relationship with food consumption frequencies.

    Science.gov (United States)

    Vanaelst, Barbara; Huybrechts, Inge; Michels, Nathalie; Vyncke, Krishna; Sioen, Isabelle; De Vriendt, Tineke; Flórez, Maria R; Aramendía, Maite; Balcaen, Lieve; Resano, Martin; Vanhaecke, Frank; De Henauw, Stefaan

    2012-12-01

    Although evidence suggests that hair elements may reflect dietary habits and/or mineral intake, this topic remains controversial. This study therefore presents age-specific reference values for hair concentrations of Ca, Cu, Fe, Na, Mg, P and Zn using the LMS method of Cole, and investigates the relationship between dietary habits (i.e. food consumption frequencies) and hair mineral concentrations in 218 Belgian elementary school girls by reduced rank regression (RRR). Hair minerals were quantitatively determined via inductively coupled plasma-mass spectrometry after microwave-assisted acid digestion of 6-cm long vertex posterior hair samples. The Children's Eating Habits Questionnaire-Food Frequency Questionnaire was used to obtain information on food consumption frequency of 43 food items in the month preceding hair collection. The established reference ranges were in line with data for other childhood or adolescent populations. The retained RRR factors explained 40, 50, 45, 46, 44 and 48 % of the variation of Ca, Cu, Fe, Mg, P and Zn concentrations in hair, respectively. Although this study demonstrated that a large proportion of hair mineral variation may be influenced by food consumption frequencies in elementary school girls, a number of food groups known to be rich sources of minerals did not show a relation with certain hair minerals. Future research should focus on mechanisms and processes involved in mineral incorporation and accumulation in scalp hair, in order to fully understand the importance and influence of diet on hair minerals.

  8. Relative frequency of immature CD34+/CD90+ subset in peripheral blood following mobilization correlates closely and inversely with the absolute count of harvested stem cells in multiple myeloma patients

    Directory of Open Access Journals (Sweden)

    Balint Bela

    2017-01-01

    Full Text Available Background/Aim. Stem cells (SCs guarantee complete/longterm bone marrow (BM repopulation after SC-transplants. The aim of the study was to evaluate absolute count of total SCs (determined by ISHAGE-sequential-gating protocol – SCish and relative frequency of immature CD34+/CD90+ (CD90+SCish subset in peripheral blood (PB as predictive factors of mobilization and apheresis product (AP quality. Methods. Mobilization included chemotherapy and granulocytegrowth- factor (G-CSF. Harvesting was performed by Spectra- Optia-IDL-system. The SCsish were determined as a constitutional part of CD34+ cells in the “stem-cell-region” using FC- 500 flow-cytometer. In this study, the original ISHAGEsequential- gating protocol was modified by introduction of anti-CD90-PE monoclonal-antibody into the analysis of CD90 expression on SCish (CD90+SCish. The results were presented as a percentage of SCish per nucleated-cell count, absolute SCish count in μL of the PB or the AP, percentage of the CD90+SCish expressed to SCish and absolute CD90+SCish count in μL of the PB or the AP. Results. The absolute count of total SCish and CD90+SCish was significantly higher (p = 0.0007 and p = 0.0266, respectively in the AP than in the PB samples. The CD90+SCish/total SCish indexes from PB were higher than indexes from the AP (p = 0.039. The relative frequency of CD90+SCish showed a highly significant inverse correlation with the absolute count of total SCish in both, the PB and AP (p = 0.0003 and p = 0.0013 respectively. The relative frequency of CD90+SCish from the PB also showed a significant (p = 0.0002 inverse relationship with total SCish count in the AP. Patients with less than 10% CD90+SCish in the PB had evidently higher (p = 0.0025 total SCish count in the AP. Conclusion. We speculate that lower CD90+SCish yield in the AP is not a consequence of an inferior collection efficacy, but most likely a result of several still not fully resolved immature SC

  9. The Non-absoluteness of the Leading Position of the Frequency ——On the Vocabulary Design Criteria of Teaching Chinese to Speakers of Other Language

    Directory of Open Access Journals (Sweden)

    Ma Qinghua

    2017-10-01

    Full Text Available The design criteria of the vocabulary outline of the second language teaching vary according to the teaching objectives. Under the same objective, the criteria are often more than one. The multiple criteria are sometimes compatible and sometimes conflicting. Through analyzing and evaluating the advantages and disadvantages of the new Chinese Proficiency Test (HSK Vocabulary Outline, this paper reveals the interactions between the task objectives, the criterion conditions and processing strategies, as well as the interaction relationships between the multiple criteria features of the vocabulary outline designing process, and then abstracts the general principles and overall rules. The research results subvert the habitual knowledge that the frequency criterion position ranked first, which is always popular at least in the Chinese academic circle. It finds that the leading position of frequency criterion only exists in the criteria compatibility model. In the conflict model of the locutionary criteria, the stylistic criterion and syntactic criterion are strong criteria, while the word frequency criterion relegates to the weak position. In the conflict model of the locutionary and illocutionary criteria, the illocutionary criterion is strong criterion, while the locutionary criterion relegates to the weak position, which indicates that the language can’t be above its purpose of usage. This research is conducive to the improvement of the vocabulary outline. It also has certain practical significance to the disciplinary theories of Teaching Chinese to Speakers of Other Language or even to the whole second language teaching.

  10. All-fiber versatile laser frequency reference at 2 μm for CO2 space-borne lidar applications

    Science.gov (United States)

    Schilt, Stéphane; Matthey, Renaud; Hey Tow, Kenny; Thévenaz, Luc; Südmeyer, Thomas

    2017-12-01

    We present a frequency stabilized laser at 2051 nm based on a versatile all-fibered stabilization setup. A modulation sideband locking technique is implemented to lock the laser at a controlled frequency detuning from the center of the CO2 R(30) transition envisaged for space-borne differential absorption lidar (DIAL) applications. This method relies on the use of a compact all-fibered gas reference cell that makes the setup robust and immune to mechanically induced optical misalignments. The gas cell is fabricated using a hollow-core photonic crystal fiber filled with pure CO2 at a low pressure of 20 mbar and hermetically sealed at both ends by splices to silica fibers. Different configurations of this fibered cell have been developed and are presented. With this technique, frequency stabilities below 40 kHz at 1-s integration time and <100 kHz up to 1000-s averaging time were achieved for a laser detuning by around 1 GHz from the center of the CO2 transition. These stabilities are compliant with typical requirements for the reference seed source for a space CO2 DIAL.

  11. Realization of a frequency standard at 778 nm: absolute frequency measurement of the 2S-8S/D transitions in hydrogen and deuterium and determination of the Rydberg constant; Realisation d'un etalon de frequence a 778 nm: mesure absolue des frequences 2S-8S/D des atomes d'hydrogene et de deuterium et determination de la constante de rydberg

    Energy Technology Data Exchange (ETDEWEB)

    Beauvoir, B. de

    1996-12-15

    The purpose of this work is to design a 778 nm standard laser for performing an absolute measurement of 2S-8S/D frequencies of hydrogen and deuterium atoms. This frequency calibration is based on a 5S-5D two-photon transition of the rubidium atom. Metrological performance of this laser is 10 times as good as that of He-Ne laser calibrated on iodine. It has been shown that the passage of a laser radiation through an optic fiber does not deteriorate its metrological properties. 2S-8S/8D transitions have been excited in an atomic jet by a titanium-sapphire laser. Spurious effects can shift and broaden lines. In order to prevent these effects, a theoretical line has been shaped and adjusted on experimental signals. The frequency comparison between the excitation laser and the standard laser has led to the measurement of the absolute frequency of the line concerned. The value of the Rydberg constant has been deduced: R{sub {infinity}} = 109737.3156859 (10) cm{sup -1}. The comparison of experimental data between deuterium and hydrogen has allowed us to determine the value of the Lamb shift of the 2S state of deuterium: L(2S-2P) = 1059,230 (9) MHz.

  12. MeerKAT time and frequency reference optical network: Preliminary design analysis

    Directory of Open Access Journals (Sweden)

    Enoch K. Rotich Kipnoo

    2017-05-01

    Full Text Available The MeerKAT telescope is a precursor to the Square Kilometre Array, which will rely on optical fibres to link the telescope receivers to a central processor point. The main aspects to consider for the fibre transport are astronomical data transmission as well as timing, monitoring and control. The astronomical data streams from individual dishes to a central building, while the clock signal is distributed from a central point to remote dishes in the telescope array. The MeerKAT telescope, for instance, demands highly accurate and stable clock distribution over up to 12 km of optical fibre to remote dishes. The clock distribution is required for digitisation of astronomical signals. Phase stability is thus critical both for short-term and long-term requirements. In this work, we focused on the short-term stability. Phase noise measurements were performed on optical transmitters used to distribute the clock signals so as to ascertain their contribution to the overall clock jitter of the system. A maximum jitter requirement of 130 fs for a 1.712-GHz clock signal for MeerKAT time and reference is achieved using a distributed feedback laser. We found that with optimised modulation depth, additional passive optical components in the link do not significantly degrade the phase noise response. A distributed feedback laser was proven to be a suitable optical source that will meet the performance and link budget requirements for the MeerKAT telescope.

  13. Effect of different assumptions for brain water content on absolute measures of cerebral oxygenation determined by frequency-domain near-infrared spectroscopy in preterm infants: an observational study.

    Science.gov (United States)

    Demel, Anja; Wolf, Martin; Poets, Christian F; Franz, Axel R

    2014-08-19

    Brain-water content (BWC) decreases with maturation of the brain and potentially affects parameters of cerebral oxygenation determined by near-infrared spectroscopy (NIRS). Most commercially available devices do not take these maturational changes into account. The aim of this study was to determine the effect of different assumptions for BWC on parameters of cerebral oxygenation in preterm infants. Concentrations of oxy-, deoxy- and total hemoglobin and regional cerebral oxygen saturation (rcStO2) were calculated based on absolute coefficients of absorption and scattering determined by multi-distance Frequency-Domain-NIRS assuming BWCs of 75-95%, which may be encountered in newborn infants depending on gestational and postnatal age. This range of BWC gave rise to a linear modification of the assessed NIRS parameters with a maximum change of 10%. This may result in an absolute overestimation of rcStO2 by (median (range)) 4 (1-8)%, if the calculation is based on the lowest BWC (75%) in an extremely preterm infant with an anticipated BWC of 95%. Clinicians wishing to rely on parameters of cerebral oxygenation determined by NIRS should consider that maturational changes in BWC not taken into account by most devices may result in a deviation of cerebral oxygenation readings by up to 8% from the correct value.

  14. Frequency of Metabolic Risk Factors in Children with Urinary Tract Stones Referred to Hamadan Pediatric Nephrology Clinic

    Directory of Open Access Journals (Sweden)

    H.E. Momtaz

    2012-07-01

    Full Text Available Introduction & Objective: Urinary stones are among the most common complaints referred to nephrologist and urologists. Although incidence of urolithiasis is low in children compared to adults and only 7% of all urinary stones are diagnosed before the age of 16 but stones are detected more frequently in pediatric age group in recent years. Metabolic derangements, infection, neurogenic bladder and urinary obstruction are major risk factors of urolithiasis. Common metabolic risk factors of urolithiasis in children are hypercalciuria, uricosuria, hypocitraturia, hyperoxaluria, metabolic acidosis and cystinuria. There are many clinical studies about the frequency of these metabolic risk factors with different results reflecting difference in diet, geographic area and genetics in study populations. In this study we tried to evaluate the frequency of metabolic causes of urinary stones in children referred to Hamadan pediatric nephrology clinic.Materials & Methods: In this cross sectional-descriptive study 156 patients referred due to urinary stones to pediatric nephrology clinic underwent thorough metabolic evaluations including: serum calcium,phosphorus, uric acid, creatinine and non fasting random urine sample for calcium, creatinine , uric acid , oxalate, citrate and cystine . urine solute: creatinine ratios were calculated and compared with normative data.Results: Of 156 patients 136(87.2% had metabolic derangements including: hyperuricosuria in 71 (45.5%, hypercalciuria in 41(26.3%, hypocitraturia in 26 (16.7%, hyperoxaluria in 16(10.3%,cystinuria in 1(0.6% and metabolic acidosis in 39 (25%.Conclusion: High rate of metabolic derangement in pediatric urinary stone patients mandates proper metabolic evaluation in all of them. hyperuricosuria was the most common metbolic finding instead of hypercalciuria in this study. This could be due to differences in diet, geographic area and genetic background in various populations.(Sci J Hamadan Univ Med Sci

  15. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  16. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  17. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  18. Frequency and Clinical Manifestations of Scabies in Suspected Patients Referred to Health Centers of Kashan, Central Iran (2010 - 2014

    Directory of Open Access Journals (Sweden)

    Sima Rasti

    2017-02-01

    Full Text Available Background Scabies is one of the most common itching contagious skin disorder in the world. The agent of disease is Sarcoptes scabiei. Objectives This study was conducted to determine the frequency and clinical manifestations of S. scabies in suspected patients referred to health centers of Kashan during 2010 - 2014. Methods This cross-sectional study was performed on 129 patients suspected to Sarcoptes scabiei. The demographic and clinical symptoms for each of patients were recorded in questionnaire by interview. A deep skin scrap was prepared and wet smear were prepared using 10% KOH. By observation of each form of Sarcoptes was identified as positive sample. The data were recorded in Spss. ver 16.5 and analyzed by X2 and fisher exact tests. Results The results of this study showed that 28 (21.7 % were Sarcoptes positive. The frequency of sarcoptes was higher in males (23% than females (20.6%. The difference was not statistically significant. The most cases were isolated in spring and winter. Sarcoptes infestation was the most in elderly and patients undergone dialysis. There is significant difference between disease and age group and underlying disease (P = 0.03, P = 0.014; respectively. Erosion or pustule was the most clinical signs in positive cases. Conclusions The results of study showed that the rate of scabies infestation in Kashan is relatively high, and the most cases were in elderly patients. Health education to increase awareness of the families for prevention of scabies was recommended.

  19. Frequency of Intestinal Parasitic Infections among Individuals Referred to the Medical Center Laboratories in Nahavand City, Hamadan Province, Western Iran

    Directory of Open Access Journals (Sweden)

    Ali Haghighi

    2015-07-01

    Full Text Available Background: Intestinal parasitic infections (IPIs cause serious public health problem in the world, especially those located in tropical and subtropical areas. This study was conducted with the aim of obtaining frequency of intestinal parasites in referred people to the Nahavand city laboratories, Hamadan province, western Iran.Materials and Methods: A comparative cross-sectional study was conducted among checkup individuals and patients referred to laboratories of Nahavand County. A total of 371 stool samples (150 from checkup individuals and 221 from patients were selected by using systematic random sampling during summer 2014.  The stool specimens were examined macroscopically, and microscopically by using direct slide smear (saline wet mount and lugol staining, formaldehyde - diethyl ether concentration, trichrome staining and modified Ziehl-Neelsen staining techniques. The results were analyzed using SPSS version 16 and Chi-square test.Results: Ninety two patients (24.8% were infected with single or multiple intestinal parasites. The overall prevalence of IPIs in checkup individuals and patients was 21.3% and 27.1%, respectively. The frequency of the observed intestinal parasites was: Blastocystis spp. 72 (19.4%, Entamoeba coli 7 (1/9%, Endolimax nana 7 (1/9%, Giardia lamblia 5 (1/3%, Cryptosporidium spp. 3 (0.8%, Entamoeba hartmanni 3 (0.8%, Entamoeba histolitica/E. dispar 1 (0.3%, Trichomonas hominies 1 (0.3%, Chilomastix mesnili 1 (0.3%, Iodamoeba butschlii 1 (0.3% and Enterobius vermicularis egg l (0.3%.Conclusion: The proportion of observed protozoan parasites 91 (24.5% is higher than helminthes infection 1 (0.3%. The worm infections in Nahavand city was dramatically decreased over the past decades, induced increases in public health at the community level.  Blastocystis spp. was the predominant intestinal parasite in people referred to the Nahavand city laboratories.  Proportion of pathogenic IPIs among patients 4.07% (9 of 221 was

  20. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  1. Decoherence at absolute zero

    OpenAIRE

    Sinha, Supurna

    2005-01-01

    We present an analytical study of the loss of quantum coherence at absolute zero. Our model consists of a harmonic oscillator coupled to an environment of harmonic oscillators at absolute zero. We find that for an Ohmic bath, the offdiagonal elements of the density matrix in the position representation decay as a power law in time at late times. This slow loss of coherence in the quantum domain is qualitatively different from the exponential decay observed in studies of high temperature envir...

  2. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  3. Absolute metrology for space interferometers

    Science.gov (United States)

    Salvadé, Yves; Courteville, Alain; Dändliker, René

    2017-11-01

    The crucial issue of space-based interferometers is the laser interferometric metrology systems to monitor with very high accuracy optical path differences. Although classical high-resolution laser interferometers using a single wavelength are well developed, this type of incremental interferometer has a severe drawback: any interruption of the interferometer signal results in the loss of the zero reference, which requires a new calibration, starting at zero optical path difference. We propose in this paper an absolute metrology system based on multiplewavelength interferometry.

  4. Mapping of radio frequency electromagnetic field exposure levels in outdoor environment and comparing with reference levels for general public health.

    Science.gov (United States)

    Cansiz, Mustafa; Abbasov, Teymuraz; Kurt, M Bahattin; Celik, A Recai

    2018-03-01

    In this study, radio frequency electromagnetic field exposure levels were measured on the main streets in the city center of Diyarbakır, Turkey. Measured electric field levels were plotted on satellite imagery of Diyarbakır and were compared with exposure guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Exposure measurements were performed in dense urban, urban and suburban areas each day for 7 consecutive days. The measurement system consisted of high precision and portable spectrum analyzer, three-axis electric field antenna, connection cable and a laptop which was used to record the measurement samples as a data logger. The highest exposure levels were detected for two places, which are called Diclekent and Batıkent. It was observed that the highest instantaneous electric field strength value for Batıkent was 7.18 V/m and for Diclekent was 5.81 V/m. It was statistically determined that the main contributor band to the total exposure levels was Universal Mobile Telecommunications System band. Finally, it was concluded that all measured exposure levels were lower than the reference levels recommended by ICNIRP for general public health.

  5. Optimization of a digital lock-in algorithm with a square-wave reference for frequency-divided multi-channel sensor signal detection.

    Science.gov (United States)

    Zhang, Shengzhao; Li, Gang; Lin, Ling; Zhao, Jing

    2016-08-01

    A digital lock-in detection technique is commonly used to measure the amplitude and phase of a selected frequency signal. A technique that uses a square wave as the reference signal has an advantage over the one using a sinusoidal wave due to its easier implementation and higher computational efficiency. However, demodulating multiple-frequency composite signals using square wave reference may result in interference between channels. To avoid interference between channels and reduce the computational complexity, we modify the calculations and determine the optimal parameter settings of the low-pass filter and carrier frequency, as detailed in this paper. The results of our analysis show that when the length of the average filter and carrier frequencies are properly set, the interference between the channels is removed. This optimization produces the digital lock-in detection suitable for measuring multi-channel sensor signals.

  6. Absolute pitch--electrophysiological evidence.

    Science.gov (United States)

    Barnea, A; Granot, R; Pratt, H

    1994-02-01

    People who have the ability to label or to produce notes without any reference are considered to possess Absolute Pitch (AP). Others, who need a reference in order to identify the notes, possess Relative Pitch (RP). The AP ability is assumed to reflect a unique, language-like representation of non-lexical musical notes in memory. The purpose of this study was to examine this assumption by comparing Event Related Potentials (ERP) of musicians with and without AP, to lexical and non-lexical representation of musical material. Subjects were eighteen young adult musicians. Seven were AP and eleven RP. Auditory stimuli, presented through earphones, were piano notes (non-lexical) or a voice saying the note's name (lexical). Visual stimuli, presented on a computer display were note symbols (non-lexical) or letters (lexical). Subjects performed a number of tasks, combining the two modalities (visual and auditory) and stimulus types (lexical and non-lexical), and reaction times (RT), performance accuracy and evoked potentials were recorded. The tasks forced the subjects to transfer mental representations of musical material from one mode to another. Our most important findings were the differences, between groups, in the scalp distribution of P300 amplitudes. We conclude that absolute pitch possessors use the same internal language as relative pitch possessors, when possible, but the distribution of the underlying brain activity is different between AP and RP subjects.

  7. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  8. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 6. Approach to Absolute Zero 0.3 K. to a Few Milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 6 June 1997 pp 6-14. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/06/0006-0014 ...

  9. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 2. Approach to Absolute Zero From 4. 22 K. to 0. 3 K. R Srinivasan. Series Article Volume 2 Issue 2 February 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/02/0008-0016 ...

  10. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  11. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  12. Generation of optical frequencies out of the frequency comb of a femtosecond laser for DWDM telecommunication

    International Nuclear Information System (INIS)

    Kim, Y-J; Chun, B J; Kim, Y; Hyun, S; Kim, S-W

    2010-01-01

    We exploit the frequency comb of a fs laser as the frequency ruler to generate reference optical frequencies for multi-channel DWDM (dense wavelength-division-multiplexing) telecommunication. Our fiber-based scheme of single-mode extraction enables on-demand generation of optical frequencies within the telecommunication band with an absolute frequency uncertainty of 9.1×10 -13 . The linewidth of extracted optical modes is less than 1 Hz, and the instability is measured 2.3×10 -15 at 10 s averaging. This outstanding performance of optical frequency generation would lead to a drastic improvement of the spectral efficiency for the next-generation DWDM telecommunication

  13. Telling in-tune from out-of-tune: widespread evidence for implicit absolute intonation.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Huang, Alex; Rutstein, Brooke; Nusbaum, Howard C

    2017-04-01

    Absolute pitch (AP) is the rare ability to name or produce an isolated musical note without the aid of a reference note. One skill thought to be unique to AP possessors is the ability to provide absolute intonation judgments (e.g., classifying an isolated note as "in-tune" or "out-of-tune"). Recent work has suggested that absolute intonation perception among AP possessors is not crystallized in a critical period of development, but is dynamically maintained by the listening environment, in which the vast majority of Western music is tuned to a specific cultural standard. Given that all listeners of Western music are constantly exposed to this specific cultural tuning standard, our experiments address whether absolute intonation perception extends beyond AP possessors. We demonstrate that non-AP listeners are able to accurately judge the intonation of completely isolated notes. Both musicians and nonmusicians showed evidence for absolute intonation recognition when listening to familiar timbres (piano and violin). When testing unfamiliar timbres (triangle and inverted sine waves), only musicians showed weak evidence of absolute intonation recognition (Experiment 2). Overall, these results highlight a previously unknown similarity between AP and non-AP possessors' long-term musical note representations, including evidence of sensitivity to frequency.

  14. Absolute Memory for Tempo in Musicians and Non-Musicians.

    Science.gov (United States)

    Gratton, Irene; Brandimonte, Maria A; Bruno, Nicola

    2016-01-01

    The ability to remember tempo (the perceived frequency of musical pulse) without external references may be defined, by analogy with the notion of absolute pitch, as absolute tempo (AT). Anecdotal reports and sparse empirical evidence suggest that at least some individuals possess AT. However, to our knowledge, no systematic assessments of AT have been performed using laboratory tasks comparable to those assessing absolute pitch. In the present study, we operationalize AT as the ability to identify and reproduce tempo in the absence of rhythmic or melodic frames of reference and assess these abilities in musically trained and untrained participants. We asked 15 musicians and 15 non-musicians to listen to a seven-step `tempo scale' of metronome beats, each associated to a numerical label, and then to perform two memory tasks. In the first task, participants heard one of the tempi and attempted to report the correct label (identification task), in the second, they saw one label and attempted to tap the correct tempo (production task). A musical and visual excerpt was presented between successive trials as a distractor to prevent participants from using previous tempi as anchors. Thus, participants needed to encode tempo information with the corresponding label, store the information, and recall it to give the response. We found that more than half were able to perform above chance in at least one of the tasks, and that musical training differentiated between participants in identification, but not in production. These results suggest that AT is relatively wide-spread, relatively independent of musical training in tempo production, but further refined by training in tempo identification. We propose that at least in production, the underlying motor representations are related to tactus, a basic internal rhythmic period that may provide a body-based reference for encoding tempo.

  15. Precise frequency measurements of iodine hyperfine transitions at 671 nm.

    Science.gov (United States)

    Huang, Yao-Chin; Chen, Hsuan-Chen; Chen, Shih-En; Shy, Jow-Tsong; Wang, Li-Bang

    2013-03-01

    We report absolute frequency measurements on the a(1), a(10), and a(15) hyperfine components of the R(78) 4-6 line of (127)I(2). An external-cavity diode laser system at 671 nm is frequency-stabilized to the saturated absorption center obtained by modulation transfer spectroscopy in an iodine vapor cell. Its absolute frequency is measured by an optical frequency comb. The effect of pressure shift is investigated to obtain the absolute transition frequency at zero pressure. Our determination of the line centers reaches a precision of better than 40 kHz and will provide useful input for theoretical calculations. This frequency-stabilized laser can be used as a reference laser for the spectroscopy of lithium D lines.

  16. High accuracy absolute distance metrology

    Science.gov (United States)

    Swinkels, Bas L.; Bhattacharya, Nandini; Verlaan, Ad L.; Braat, Joseph J. M.

    2017-11-01

    One of ESA's future missions is the Darwin Space Interferometer, which aims to detect planets around nearby stars using optical aperture synthesis with free-flying telescopes. Since this involves interfering white (infra-red) light over large distances, the mission is not possible without a complex metrology system that monitors various speeds, distances and angles between the satellites. One of its sub-systems should measure absolute distances with an accuracy of around 70 micrometer over distances up to 250 meter. To enable such measurements, we are investigating a technique called frequency sweeping interferometry, in which a single laser is swept over a large known frequency range. Central to our approach is the use of a very stable, high finesse Fabry-Ṕerot cavity, to which the laser is stabilized at the endpoints of the frequency sweep. We will discuss the optical set-up, the control system that controls the fast sweeping, the calibration and the data analysis. We tested the system using long fibers and achieved a repeatability of 50 micrometers at a distance of 55 meters. We conclude with some recommendations for further improvements and the adaption for use in space.

  17. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...... to the lasso. The lasso is applied both directly as a calibration method and as a method to select important variables/wave lengths. It is demonstrated that the lasso algorithm, in general, leads to parameter estimates of which some are zero while others are quite large (compared to e.g. the traditional PLS...

  18. Absolute Gravimetry in Fennoscandia

    DEFF Research Database (Denmark)

    Pettersen, B. R; TImmen, L.; Gitlein, O.

    away from this central location. An oval shaped zero uplift isoline tracks the general western and northern coastline of Norway and the Kola peninsula. It returns southwest through Russian Karelia and touches the southern tip of Sweden and northern Denmark. The uplift area (as measured by present day...... motions) has its major axis in the direction of southwest to northeast and covers a distance of about 2000 km. Absolute gravimetry was made in Finland and Norway in 1976 with a rise-and fall instrument. A decade later the number of gravity stations was expanded by JILAg-5, in Finland from 1988, in Norway...... acquired by IfE (FG5-220), FGI (FG5-221), and UMB (FG5-226). New absolute gravity stations were established by the national mapping agencies in Denmark, Norway, and Sweden. The total number of prepared sites in Fennoscandia is now about 30. Most of them are co-located with permanent GPS, for many of which...

  19. An Initial Assessment of the Surface Reference Technique Applied to Data from the Dual-Frequency Precipitation Radar (DPR) on the GPM Satellite

    Science.gov (United States)

    Meneghini, Robert; Kim, Hyokyung; Liao, Liang; Jones, Jeffrey A.; Kwiatkowski, John M.

    2015-01-01

    It has long been recognized that path-integrated attenuation (PIA) can be used to improve precipitation estimates from high-frequency weather radar data. One approach that provides an estimate of this quantity from airborne or spaceborne radar data is the surface reference technique (SRT), which uses measurements of the surface cross section in the presence and absence of precipitation. Measurements from the dual-frequency precipitation radar (DPR) on the Global Precipitation Measurement (GPM) satellite afford the first opportunity to test the method for spaceborne radar data at Ka band as well as for the Ku-band-Ka-band combination. The study begins by reviewing the basis of the single- and dual-frequency SRT. As the performance of the method is closely tied to the behavior of the normalized radar cross section (NRCS or sigma(0)) of the surface, the statistics of sigma(0) derived from DPR measurements are given as a function of incidence angle and frequency for ocean and land backgrounds over a 1-month period. Several independent estimates of the PIA, formed by means of different surface reference datasets, can be used to test the consistency of the method since, in the absence of error, the estimates should be identical. Along with theoretical considerations, the comparisons provide an initial assessment of the performance of the single- and dual-frequency SRT for the DPR. The study finds that the dual-frequency SRT can provide improvement in the accuracy of path attenuation estimates relative to the single-frequency method, particularly at Ku band.

  20. Frequency of anti-Chlamydia trachomatis antibodies in infertile women referred to Tabriz Al-Zahra hospital

    Directory of Open Access Journals (Sweden)

    Mahtab Sattari

    2017-08-01

    Full Text Available Background: Infertility is one of the major issues in society and its incidence is estimated to be almost 10-15%. Chlamydia trachomatis (C. trachomatis is an important cause of sexually transmitted diseases leading to infertility. Objective: This study was designed to determine the frequency of anti-C. trachomatis antibodies in infertile women at Al-zahra hospital, Tabriz, Iran. Materials and Methods: In this cross-sectional study, the blood samples were collected randomly from 184 infertile women (case group and 100 pregnant women (control group. The frequency of specific IgG and IgM anti-C. trachomatis antibodies were evaluated using ELISA method. Results: The frequency of IgG anti-C. trachomatis antibody in the control and case groups was 18% and 35.88%, respectively. IgM anti-C. trachomatis antibody was found in 2% of controls and 5.44% of infertile women. Our results showed the significant differences between the case and control groups in anti-C. trachomatis antibodies (IgG, p=0.035 and IgM, p=0.004. Also, no significant relation was seen between the frequency of anti-C. trachomatis antibodies and age, location, and tubal factor infertility in our two study groups. Conclusion: According to high frequency of antibody anti-C. trachomatis among infertile women in competition to the control group, evaluation and treatment of Chlamydia infections is necessary in these patients

  1. The new Absolute Quantum Gravimeter (AQG): first results and perspectives

    Science.gov (United States)

    Bonvalot, Sylvain; Le Moigne, Nicolas; Merlet, Sebastien; Desruelle, Bruno; Lautier-Gaud, Jean; Menoret, Vincent; Vermeulen, Pierre

    2016-04-01

    Cold atom gravimetry represents one of the most innovative evolution in gravity instrumentation since the last 20 years. The concept of measuring the gravitational acceleration by dropping atoms and the development of the first instrumental devices during this last decade quickly revealed the promising perspectives of this new generation of gravity meters enabling accurate and absolute measurements of the Earth's gravity field for a wide range of applications (geophysics, geodesy, metrology, etc.). The Absolute Quantum Gravimeter (AQG) gravity meter, developed by MUQUANS (Talence, France - http://www.muquans.com/) with the support of RESIF, the French Seismologic and Geodetic Network (http://www.resif.fr/) belongs to this new generation of instruments. It also represents the first commercial device based on the utilization of advanced matter-wave interferometry techniques, which allow to characterize precisely the vertical acceleration experienced by a cloud of cold atoms. Recently, the first operational unit (AQG01) has been achieved as a compact transportable gravimeter with the aim of satisfying absolute gravity measurements in laboratory conditions under the following specifications: measurements the μGal level at a few Hz cycling frequency, sensitivity of 50μGal/√Hz, immunity to ground vibrations, easy and quickness of operation, automated continuous data acquisition for several months, etc. In order to evaluate the current performances of the AQG01, several experiments are carried out in collaboration between RESIF user's teams and the MUQUANS manufacturer on different reference gravity sites and laboratories in France. These measurements performed in indoor conditions including simultaneous observations with classical reference gravity instruments (corner-cube absolute gravity meters, relative superconducting meters) as well with the Cold Atom Gravity meter (CAG) developed by LNE-SYRTE, lead to a first objective characterization of the performances of

  2. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  3. Improved imputation of low-frequency and rare variants using the UK10K haplotype reference panel

    DEFF Research Database (Denmark)

    Huang, Jie; Howie, Bryan; Mccarthy, Shane

    2015-01-01

    Imputing genotypes from reference panels created by whole-genome sequencing (WGS) provides a cost-effective strategy for augmenting the single-nucleotide polymorphism (SNP) content of genome-wide arrays. The UK10K Cohorts project has generated a data set of 3,781 whole genomes sequenced at low de...

  4. Improved imputation of low-frequency and rare variants using the UK10K haplotype reference panel

    NARCIS (Netherlands)

    J. Huang (Jie); B. Howie (Bryan); S. McCarthy (Shane); Y. Memari (Yasin); K. Walter (Klaudia); J.L. Min (Josine L.); P. Danecek (Petr); G. Malerba (Giovanni); E. Trabetti (Elisabetta); H.-F. Zheng (Hou-Feng); G. Gambaro (Giovanni); J.B. Richards (Brent); R. Durbin (Richard); N.J. Timpson (Nicholas); J. Marchini (Jonathan); N. Soranzo (Nicole); S.H. Al Turki (Saeed); A. Amuzu (Antoinette); C. Anderson (Carl); R. Anney (Richard); D. Antony (Dinu); M.S. Artigas; M. Ayub (Muhammad); S. Bala (Senduran); J.C. Barrett (Jeffrey); I. Barroso (Inês); P.L. Beales (Philip); M. Benn (Marianne); J. Bentham (Jamie); S. Bhattacharya (Shoumo); E. Birney (Ewan); D.H.R. Blackwood (Douglas); M. Bobrow (Martin); E. Bochukova (Elena); P.F. Bolton (Patrick F.); R. Bounds (Rebecca); C. Boustred (Chris); G. Breen (Gerome); M. Calissano (Mattia); K. Carss (Keren); J.P. Casas (Juan Pablo); J.C. Chambers (John C.); R. Charlton (Ruth); K. Chatterjee (Krishna); L. Chen (Lu); A. Ciampi (Antonio); S. Cirak (Sebahattin); P. Clapham (Peter); G. Clement (Gail); G. Coates (Guy); M. Cocca (Massimiliano); D.A. Collier (David); C. Cosgrove (Catherine); T. Cox (Tony); N.J. Craddock (Nick); L. Crooks (Lucy); S. Curran (Sarah); D. Curtis (David); A. Daly (Allan); I.N.M. Day (Ian N.M.); A.G. Day-Williams (Aaron); G.V. Dedoussis (George); T. Down (Thomas); Y. Du (Yuanping); C.M. van Duijn (Cornelia); I. Dunham (Ian); T. Edkins (Ted); R. Ekong (Rosemary); P. Ellis (Peter); D.M. Evans (David); I.S. Farooqi (I. Sadaf); D.R. Fitzpatrick (David R.); P. Flicek (Paul); J. Floyd (James); A.R. Foley (A. Reghan); C.S. Franklin (Christopher S.); M. Futema (Marta); L. Gallagher (Louise); P. Gasparini (Paolo); T.R. Gaunt (Tom); M. Geihs (Matthias); D. Geschwind (Daniel); C.M.T. Greenwood (Celia); H. Griffin (Heather); D. Grozeva (Detelina); X. Guo (Xiaosen); X. Guo (Xueqin); H. Gurling (Hugh); D. Hart (Deborah); A.E. Hendricks (Audrey E.); P.A. Holmans (Peter A.); L. Huang (Liren); T. Hubbard (Tim); S.E. Humphries (Steve E.); M.E. Hurles (Matthew); P.G. Hysi (Pirro); V. Iotchkova (Valentina); A. Isaacs (Aaron); D.K. Jackson (David K.); Y. Jamshidi (Yalda); J. Johnson (Jon); C. Joyce (Chris); K.J. Karczewski (Konrad); J. Kaye (Jane); T. Keane (Thomas); J.P. Kemp (John); K. Kennedy (Karen); A. Kent (Alastair); J. Keogh (Julia); F. Khawaja (Farrah); M.E. Kleber (Marcus); M. Van Kogelenberg (Margriet); A. Kolb-Kokocinski (Anja); J.S. Kooner (Jaspal S.); G. Lachance (Genevieve); C. Langenberg (Claudia); C. Langford (Cordelia); D. Lawson (Daniel); I. Lee (Irene); E.M. van Leeuwen (Elisa); M. Lek (Monkol); R. Li (Rui); Y. Li (Yingrui); J. Liang (Jieqin); H. Lin (Hong); R. Liu (Ryan); J. Lönnqvist (Jouko); L.R. Lopes (Luis R.); M.C. Lopes (Margarida); J. Luan; D.G. MacArthur (Daniel G.); M. Mangino (Massimo); G. Marenne (Gaëlle); W. März (Winfried); J. Maslen (John); A. Matchan (Angela); I. Mathieson (Iain); P. McGuffin (Peter); A.M. McIntosh (Andrew); A.G. McKechanie (Andrew G.); A. McQuillin (Andrew); S. Metrustry (Sarah); N. Migone (Nicola); H.M. Mitchison (Hannah M.); A. Moayyeri (Alireza); J. Morris (James); R. Morris (Richard); D. Muddyman (Dawn); F. Muntoni; B.G. Nordestgaard (Børge G.); K. Northstone (Kate); M.C. O'donovan (Michael); S. O'Rahilly (Stephen); A. Onoufriadis (Alexandros); K. Oualkacha (Karim); M.J. Owen (Michael J.); A. Palotie (Aarno); K. Panoutsopoulou (Kalliope); V. Parker (Victoria); J.R. Parr (Jeremy R.); L. Paternoster (Lavinia); T. Paunio (Tiina); F. Payne (Felicity); S.J. Payne (Stewart J.); J.R.B. Perry (John); O.P.H. Pietiläinen (Olli); V. Plagnol (Vincent); R.C. Pollitt (Rebecca C.); S. Povey (Sue); M.A. Quail (Michael A.); L. Quaye (Lydia); L. Raymond (Lucy); K. Rehnström (Karola); C.K. Ridout (Cheryl K.); S.M. Ring (Susan); G.R.S. Ritchie (Graham R.S.); N. Roberts (Nicola); R.L. Robinson (Rachel L.); D.B. Savage (David); P.J. Scambler (Peter); S. Schiffels (Stephan); M. Schmidts (Miriam); N. Schoenmakers (Nadia); R.H. Scott (Richard H.); R.A. Scott (Robert); R.K. Semple (Robert K.); E. Serra (Eva); S.I. Sharp (Sally I.); A.C. Shaw (Adam C.); H.A. Shihab (Hashem A.); S.-Y. Shin (So-Youn); D. Skuse (David); K.S. Small (Kerrin); C. Smee (Carol); G.D. Smith; L. Southam (Lorraine); O. Spasic-Boskovic (Olivera); T.D. Spector (Timothy); D. St. Clair (David); B. St Pourcain (Beate); J. Stalker (Jim); E. Stevens (Elizabeth); J. Sun (Jianping); G. Surdulescu (Gabriela); J. Suvisaari (Jaana); P. Syrris (Petros); I. Tachmazidou (Ioanna); R. Taylor (Rohan); J. Tian (Jing); M.D. Tobin (Martin); D. Toniolo (Daniela); M. Traglia (Michela); A. Tybjaerg-Hansen; A.M. Valdes; A.M. Vandersteen (Anthony M.); A. Varbo (Anette); P. Vijayarangakannan (Parthiban); P.M. Visscher (Peter); L.V. Wain (Louise); J.T. Walters (James); G. Wang (Guangbiao); J. Wang (Jun); Y. Wang (Yu); K. Ward (Kirsten); E. Wheeler (Eleanor); P.H. Whincup (Peter); T. Whyte (Tamieka); H.J. Williams (Hywel J.); K.A. Williamson (Kathleen); C. Wilson (Crispian); S.G. Wilson (Scott); K. Wong (Kim); C. Xu (Changjiang); J. Yang (Jian); G. Zaza (Gianluigi); E. Zeggini (Eleftheria); F. Zhang (Feng); P. Zhang (Pingbo); W. Zhang (Weihua)

    2015-01-01

    textabstractImputing genotypes from reference panels created by whole-genome sequencing (WGS) provides a cost-effective strategy for augmenting the single-nucleotide polymorphism (SNP) content of genome-wide arrays. The UK10K Cohorts project has generated a data set of 3,781 whole genomes sequenced

  5. Estimating KIR Haplotype Frequencies on a Cohort of 10,000 Individuals: A Comprehensive Study on Population Variations, Typing Resolutions, and Reference Haplotypes.

    Directory of Open Access Journals (Sweden)

    Cynthia Vierra-Green

    Full Text Available The killer cell immunoglobulin-like receptors (KIR mediate human natural killer (NK cell cytotoxicity via activating or inhibiting signals. Although informative and functional haplotype patterns have been reported, most genotyping has been performed at resolutions that are structurally ambiguous. In order to leverage structural information given low-resolution genotypes, we performed experiments to quantify the effects of population variations, reference haplotypes, and genotyping resolutions on population-level haplotype frequency estimations as well as predictions of individual haplotypes. We genotyped 10,157 unrelated individuals in 5 populations (518 African American[AFA], 258 Asian or Pacific Islander[API], 8,245 European[EUR], 1,073 Hispanic[HIS], and 63 Native American[NAM] for KIR gene presence/absence (PA, and additionally half of the AFA samples for KIR gene copy number variation (CNV. A custom EM algorithm was used to estimate haplotype frequencies for each population by interpretation in the context of three sets of reference haplotypes. The algorithm also assigns each individual the haplotype pairs of maximum likelihood. Generally, our haplotype frequency estimates agree with similar previous publications to within <5% difference for all haplotypes. The exception is that estimates for NAM from the U.S. showed higher frequency association of cB02 with tA01 (+14% instead of tB01 (-8.5% compared to a previous study of NAM from south of the U.S. The higher-resolution CNV genotyping on the AFA samples allowed unambiguous haplotype-pair assignments for the majority of individuals, resulting in a 22% higher median typing resolution score (TRS, which measures likelihood of self-match in the context of population-specific haplo- and geno-types. The use of TRS to quantify reduced ambiguity with CNV data clearly revealed the few individuals with ambiguous genotypes as outliers. It is observed that typing resolution and reference haplotype set

  6. Estimating KIR Haplotype Frequencies on a Cohort of 10,000 Individuals: A Comprehensive Study on Population Variations, Typing Resolutions, and Reference Haplotypes.

    Science.gov (United States)

    Vierra-Green, Cynthia; Roe, David; Jayaraman, Jyothi; Trowsdale, John; Traherne, James; Kuang, Rui; Spellman, Stephen; Maiers, Martin

    2016-01-01

    The killer cell immunoglobulin-like receptors (KIR) mediate human natural killer (NK) cell cytotoxicity via activating or inhibiting signals. Although informative and functional haplotype patterns have been reported, most genotyping has been performed at resolutions that are structurally ambiguous. In order to leverage structural information given low-resolution genotypes, we performed experiments to quantify the effects of population variations, reference haplotypes, and genotyping resolutions on population-level haplotype frequency estimations as well as predictions of individual haplotypes. We genotyped 10,157 unrelated individuals in 5 populations (518 African American[AFA], 258 Asian or Pacific Islander[API], 8,245 European[EUR], 1,073 Hispanic[HIS], and 63 Native American[NAM]) for KIR gene presence/absence (PA), and additionally half of the AFA samples for KIR gene copy number variation (CNV). A custom EM algorithm was used to estimate haplotype frequencies for each population by interpretation in the context of three sets of reference haplotypes. The algorithm also assigns each individual the haplotype pairs of maximum likelihood. Generally, our haplotype frequency estimates agree with similar previous publications to within <5% difference for all haplotypes. The exception is that estimates for NAM from the U.S. showed higher frequency association of cB02 with tA01 (+14%) instead of tB01 (-8.5%) compared to a previous study of NAM from south of the U.S. The higher-resolution CNV genotyping on the AFA samples allowed unambiguous haplotype-pair assignments for the majority of individuals, resulting in a 22% higher median typing resolution score (TRS), which measures likelihood of self-match in the context of population-specific haplo- and geno-types. The use of TRS to quantify reduced ambiguity with CNV data clearly revealed the few individuals with ambiguous genotypes as outliers. It is observed that typing resolution and reference haplotype set influence

  7. Neutral Atom Frequency Reference in the Deep Ultraviolet with FractionalUncertainty=5.7×10-15

    Science.gov (United States)

    McFerran, J. J.; Yi, L.; Mejri, S.; Di Manno, S.; Zhang, W.; Guéna, J.; Le Coq, Y.; Bize, S.

    2012-05-01

    We present an assessment of the (6s2) S01↔(6s6p)P03 clock transition frequency in Hg199 with an uncertainty reduction of nearly 3 orders of magnitude and demonstrate an atomic quality factor Q of ˜1014. The Hg199 atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697±0.0011nm and at a lattice depth of 20ER. The atoms are loaded from a single-stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. We find the frequency of the clock transition to be 1128575290808162.0±6.4(syst)±0.3(stat)Hz (i.e., with fractionaluncertainty=5.7×10-15). Neither an atom number nor second order Zeeman dependence has yet been detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing, and detection.

  8. Neutral atom frequency reference in the deep ultraviolet with fractional uncertainty = 5.7×10(-15).

    Science.gov (United States)

    McFerran, J J; Yi, L; Mejri, S; Di Manno, S; Zhang, W; Guéna, J; Le Coq, Y; Bize, S

    2012-05-04

    We present an assessment of the (6s2) (1)S0 ↔ (6s6p)(3)P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly 3 orders of magnitude and demonstrate an atomic quality factor Q of ∼10(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697±0.0011  nm and at a lattice depth of 20E(R). The atoms are loaded from a single-stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. We find the frequency of the clock transition to be 1,128,575,290,808,162.0±6.4(syst)±0.3(stat)  Hz (i.e., with fractional uncertainty=5.7×10(-15)). Neither an atom number nor second order Zeeman dependence has yet been detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing, and detection.

  9. Improvement of the Positioning Accuracy of a Single Frequency Receiver using Observables of the Dual GPS Reference Stations

    Directory of Open Access Journals (Sweden)

    Byung-Kyu Choi

    2008-09-01

    Full Text Available With the growth of civil and commercial applications, the Global Navigation Satellite System(GNSS that provides the positioning, navigation, and timing information affects to our life. In order to meet all the requirements of civilian user, new positioning technology with the accuracy of 10cm level has been applied and the positioning accuracy is getting improved. In this study, dual coverage(DAEJ, SUWN GPS measurements were applied to improve the positioning accuracy for GPS L1 single frequency users. We processed some GPS data obtained from the distributed test sites in the wide area over Korea Peninsula. As a result, the combined solution output using dual coverage showed more improved positioning accuracy than that of single coverage.

  10. Absolute risk, absolute risk reduction and relative risk

    Directory of Open Access Journals (Sweden)

    Jose Andres Calvache

    2012-12-01

    Full Text Available This article illustrates the epidemiological concepts of absolute risk, absolute risk reduction and relative risk through a clinical example. In addition, it emphasizes the usefulness of these concepts in clinical practice, clinical research and health decision-making process.

  11. Frequency of Eyelid Malpositions and their Treatment Results in Patients Referred to Ophthalmology Clinics in Educational Yazd Hospitals

    Directory of Open Access Journals (Sweden)

    M Rafieian

    2012-10-01

    Full Text Available Introduction: Entropion and ectropion with involutional changes are the most common eyelid malpositions. Entropion is a condition in which the eyelid margin turns inwards against the globe and ectropion is a malposition in which the lid turns outwards or is pulled away its normal position from the globe. Knowledge of eyelid problems and their abnormalities is a key to plan a successful surgical procedure. Methods: This descriptive study lasted from Sep. 2008 to March 2009. We evaluated 78 patients with eyelid malpositions who referred to educational hospitals of Yazd. The patients were examined by an eye specialist. Each patient’s demographic data, type of eyelid malposition, specific treatment results and 6-month follow up of each patient were recorded by the questioners and then were analyzed statistically by SPSS13 software, chi-square and fisher exact test. Results: Among 78 cases, entropion was observed in 41 cases(52.6%, trichiasis in 31 cases(39.7%, ectropion in 27 cases(34.6% and distichiasis in 3 cases (3.8%. The Wies procedure proved to be influential in entropion treatment and lateral tarsal strip canthoplasty surgery also reported acceptable results in ectropion. Conclusion: The involutional changes were the most common causing factors for eyelid malpositions. Entropion appears most prevalently specially in right upper eyelid. The Wies and lateral tarsal strip canthoplasty procedures were thoroughly successful in treatment of entropion and ectropion of either upper or lower eyelids

  12. Investigating Frequency of Reasons for Referring to CBCT in a Private Imaging Center in Yazd from 2010 to 2012

    Directory of Open Access Journals (Sweden)

    B Rafii

    2013-08-01

    Full Text Available Introduction: A CBCT system (Cone Beam Computed Tomography is a new method in the application of radiography in dental science that provides three-dimensional data of the hard and soft tissue, without magnification or distotion. Information obtained via this diagnostic imaging can be utilized in treatment planning. Methods: In this retrospective descriptive study, the CBCT prescription of all dentists (DDS & Expert were investigated in a private Center of Oral and Maxillofacial Radiology (426 patients in Yazd from Oct 2010 to Dec 2012 (26 months and the following information was extracted: age, sex, years of prescription, reason of prescription, academic level of prescriber. Moreover, data was analyzed utilizing SPSS Version 16. Results: The study results revealed that 64.8% of patients aged between 30 to 60 years. Prevalence of male and female patients was approximately equal. Most CBCT prescriptions were by general dentists (44% and then it belonged to Oral and Maxillofacial Surgeons (32.2%. CBCT was requested most for implant (88%. Number of CBCT requests in 2010 was 18.5%; in 2011 was 29.3% and in 2012 was 52.1%. Conclusion: Patients referred for evaluation before implant involve one of the main reasons for the CBCT request. However, it seems that the using CBCT was not limited to implant and will be developed in oral and maxillofacial surgery, orthodontics, root canals therapy and other dental treatments.

  13. Frequency locking of compact laser-diode modules at 633 nm

    Science.gov (United States)

    Nölleke, Christian; Leisching, Patrick; Blume, Gunnar; Jedrzejczyk, Daniel; Pohl, Johannes; Feise, David; Sahm, Alexander; Paschke, Katrin

    2018-02-01

    This work reports on a compact diode-laser module emitting at 633 nm. The emission frequency can be tuned with temperature and current, while optical feedback of an internal DBR grating ensures single-mode operation. The laser diode is integrated into a micro-fabricated package, which includes optics for beam shaping, a miniaturized optical isolator, and a vapor cell as frequency reference. The achieved absolute frequency stability is below 10-8 , while the output power can be more than 10 mW. This compact absolute frequency-stabilized laser system can replace gas lasers and may be integrated in future quantum technology devices.

  14. Frequency Invsetigation of Restorations with Potentially of Periodontal Destruction in Participants Referred to Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    ME Khajaei-Jahromi

    2013-08-01

    Full Text Available Introduction: Defective restorations such as overhang, overcontour, open margin, residual cement or subgingival margin, lead to severe plaque accumulation and prevent using oral hygiene devices and finally they can cause gingival inflammation and periodontal destruction. Therefore, this study aimed to determine the frequency of restorations that have potentiality of periodontal destruction in participants referred to Faculty of dentistry, Shahid Sadoughi University of Medical Sciences in 2011. Methods: In this descriptive cross-sectional study, patients referred to Oral Medicine department were selected to reach 150 participants. All restorations were investigated regarding the existence of overhang, overcontour, open margin, subgingival margin, and residual cement. Results: Totally, 348 restorations were investigated that within 208 amalgam fillings, 88 fillings (42.30% were with overhang. Among 79 composite fillings, 17 fillngs (21.51% had overhang and overcountour. From 65 metal ceramic crowns, 21 crowns (32.30% had open margin and 15 crowns (23.70% had subgingival margins. Moreover, residual cement was not found. Conclusion: Existence of defective restorations which interfere with periodontal health such as amalgam overhang (it revealed most frequency in this study indicates that more attempts are required to decrease such flaws.

  15. A developmental study of latent absolute pitch memory.

    Science.gov (United States)

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  16. Frequency of abnormal findings in lumbar MRI in patients With non traumatic and non surgical low back pain referred to Imam-Khomeini Hospital

    Directory of Open Access Journals (Sweden)

    Leila Aghaghazvini

    2014-08-01

    Full Text Available Background: This study was conducted to determine the frequency of abnormal discal findings in lumbar MRI in patients with non traumatic non surgical low back pain who referred to Imam-Khomeini hospital Materials and methods: This study was conducted as a descriptive – analytical cross-sectional prospective survey among 280 consecutive patients who referred to Imam-Khomeini hospital in 2008 -2009. The data were collected by check list and analysis was done by SPSS 10 Results: The mean age of the patients was 40.98. 56.1% were female Abnormal MRI was seen in 83.2% and 72.9% had disc involvement including 40.7% central, 21.1% right and 36.3% left involvements, 25.75% had bulging, 62.85% protrusion, 11.05% extrusion and finally 0.35% had sequestration. Conclusion: It may be concluded that disc protrusion and bulging are the most common findings in MRI and according to excellent ability of MRI in diagnosis of herniation, MRI is recommended in patients with non surgical non traumatic low back pain.

  17. Musical Activity Tunes Up Absolute Pitch Ability

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Ribe, Lars Riisgaard

    2014-01-01

    Absolute pitch (AP) is the ability to identify or produce pitches of musical tones without an external reference. Active AP (i.e., pitch production or pitch adjustment) and passive AP (i.e., pitch identification) are considered to not necessarily coincide, although no study has properly compared...... that APs generally undershoot when adjusting musical pitch, a tendency that decreases when musical activity increases. Finally, APs are less accurate when adjusting the pitch to black key targets than to white key targets. Hence, AP ability may be partly practice-dependent and we speculate that APs may...

  18. Reference-independent wide field fluorescence lifetime measurements using Frequency-Domain (FD) technique based on phase and amplitude crossing point.

    Science.gov (United States)

    Yahav, Gilad; Barnoy, Eran; Roth, Nir; Turgeman, Lior; Fixler, Dror

    2017-09-01

    Fluorescence lifetime imaging microscopy (FLIM) is an essential tool in many scientific fields such as biology and medicine thanks to the known advantages of the fluorescence lifetime (FLT) over the classical fluorescence intensity (FI). However, the frequency domain (FD) FLIM technique suffers from its strong dependence on the reference and its compliance to the sample. In this paper, we suggest a new way to calculate the FLT by using the crossing point (CRPO) between the modulation and phase FLTs measured over several light emitting diode (LED) DC currents values instead of either method alone. This new technique was validated by measuring homogeneous substances with known FLT, where the CRPO appears to be the optimal measuring point. Furthermore, the CRPO method was applied in heterogeneous samples. It was found that the CRPO in known mixed solutions is the weighted average of the used solutions. While measuring B16 and lymphocyte cells, the CRPO of the DAPI compound in single FLT regions was measured at 3.5 ± 0.06 ns and at 2.83 ± 0.07 ns, respectively, both of which match previous reports and multi-frequency analyses. This paper suggests the CRPO as a new method to extract the FLT in problematic cases such as high MCP gains and heterogeneous environments. In traditional FD FLIM measurements, the variation in phase angle and modulation are measured. By measuring over varying DC currents, another variation is detected in the FLT determined through the phase and modulation methods, with the CRPO indicating the true FLT. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  20. Athermal fiber laser for the SWARM absolute scalar magnetometer

    Science.gov (United States)

    Fourcault, W.; Léger, J.-M.; Costes, V.; Fratter, I.; Mondin, L.

    2017-11-01

    The Absolute Scalar Magnetometer (ASM) developed by CEA-LETI/CNES is an optically pumped 4He magnetic field sensor based on the Zeeman effect and an electronic magnetic resonance whose effects are amplified by a laser pumping process [1-2]. Consequently, the role of the laser is to pump the 4He atoms at the D0 transition as well as to allow the magnetic resonance signal detection. The ASM will be the scalar magnetic reference instrument of the three ESA Swarm satellites to be launched in 2012 in order to carry out the best ever survey of the Earth magnetic field and its temporal evolution. The sensitivity and accuracy of this magnetometer based on 4He optical pumping depend directly on the characteristics of its light source, which is the key sub-system of the sensor. We describe in this paper the selected fiber laser architecture and its wavelength stabilization scheme. Its main performance in terms of spectral emission, optical power at 1083 nm and intensity noise characteristics in the frequency bands used for the operation of the magnetometer, are then presented. Environmental testing results (thermal vacuum cycling, vibrations, shocks and ageing) are also reported at the end of this paper.

  1. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is considered.

  2. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    Abstract. The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is ...

  3. High-frequency QRS analysis compared to conventional ST-segment analysis in patients with chest pain and normal ECG referred for exercise tolerance test.

    Science.gov (United States)

    Conti, Alberto; Alesi, Andrea; Aspesi, Giovanna; De Bernardis, Niccolò; Bianchi, Simone; Coppa, Alessandro; Donnini, Chiara; Grifoni, Caterina; Becucci, Alessandro; Casula, Claudia

    2015-01-01

    The novel analysis of high-frequency QRS components (HFQRS-analysis) has been proposed in patients with chest pain (CP) and normal electrocardiography (ECG) referred for exercise tolerance test (ex-ECG). The aim of the study was to compare the diagnostic value of ex-ECG with ex-HFQRS-analysis. Patients with CP and normal ECG, troponin, and echocardiography were considered. All patients underwent ex-ECG for conventional ST-segment-analysis and ex-HFQRS-analysis. A decrease ≥ 50% of the HFQRS signal intensity recorded in at least 2 contiguous leads was considered an index of ischemia, as ST-segment depression ≥ 2 mm or ≥ 1 mm and CP on ex-ECG. Exclusion criteria were: QRS duration ≥ 120 ms and inability to exercise. End-point: The composite of coronary stenosis ≥ 70% or acute coronary syndrome, revascularization, cardiovascular death at 3-month follow-up. Three-hundred thirty-seven patients were enrolled (age 60 ± 15 years). The percent-age of age-adjusted maximal predicted heart rate was 89 ± 10 beat per minute and the maximal systolic blood pressure was 169 ± 23 mm Hg. Nineteen patients achieved the end-point. In multivariate analysis, both ex-ECG and ex-HFQRS were predictors of the end-point. The ex-HFQRS-analysis showed higher sensitivity (63% vs. 26%; p ECG-analysis. Receiver operator characteristics analysis showed the incremental diagnostic value of HFQRS (area: 0.655, 95% CI 0.60-0.71) over conventional ex-ECG (0.608, CI 0.55-0.66) and CP score (0.530, CI 0.48-0.59), however without statistical significance in pairwise comparison by C-statistic. In patients with CP submitted to ex-ECG, the novel ex-HFQRS-analysis shows a valuable incremental diagnostic value over ST-segment-analysis.

  4. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  5. Absolute beam current monitoring in endstation c

    International Nuclear Information System (INIS)

    Bochna, C.

    1995-01-01

    The first few experiments at CEBAF require approximately 1% absolute measurements of beam currents expected to range from 10-25μA. This represents errors of 100-250 nA. The initial complement of beam current monitors are of the non intercepting type. CEBAF accelerator division has provided a stripline monitor and a cavity monitor, and the authors have installed an Unser monitor (parametric current transformer or PCT). After calibrating the Unser monitor with a precision current reference, the authors plan to transfer this calibration using CW beam to the stripline monitors and cavity monitors. It is important that this be done fairly rapidly because while the gain of the Unser monitor is quite stable, the offset may drift on the order of .5μA per hour. A summary of what the authors have learned about the linearity, zero drift, and gain drift of each type of current monitor will be presented

  6. Towards absolute laser spectroscopic CO2 isotope ratio measurements

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Knowledge of isotope composition of carbon dioxide (CO2) in the atmosphere is necessary to identify sources and sinks of this key greenhouse gas. In the last years, laser spectroscopic techniques such as cavity ring-down spectroscopy (CRDS) and tunable diode laser absorption spectroscopy (TDLAS) have been shown to perform accurate isotope ratio measurements for CO2 and other gases like water vapour (H2O) [1,2]. Typically, isotope ratios are reported in literature referring to reference materials provided by e.g. the International Atomic Energy Agency (IAEA). However, there could be some benefit if field deployable absolute isotope ratio measurement methods were developed to address issues such as exhausted reference material like the Pee Dee Belemnite (PDB) standard. Absolute isotope ratio measurements would be particularly important for situations where reference materials do not even exist. Here, we present CRDS and TDLAS-based absolute isotope ratios (13C/12C ) in atmospheric CO2. We demonstrate the capabilities of the used methods by measuring CO2 isotope ratios in gas standards. We compare our results to values reported for the isotope certified gas standards. Guide to the expression of uncertainty in measurement (GUM) compliant uncertainty budgets on the CRDS and TDLAS absolute isotope ratio measurements are presented, and traceability is addressed. We outline the current impediments in realizing high accuracy absolute isotope ratio measurements using laser spectroscopic methods, propose solutions and the way forward. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] B. Kühnreich, S. Wagner, J. C. Habig,·O. Möhler, H. Saathoff, V. Ebert, Appl. Phys. B 119:177-187 (2015). [2] E. Kerstel, L. Gianfrani, Appl. Phys. B 92, 439-449 (2008).

  7. Absolute frequency shifts of iodine cells for laser stabilization

    Czech Academy of Sciences Publication Activity Database

    Lazar, Josef; Hrabina, Jan; Jedlička, Petr; Číp, Ondřej

    2009-01-01

    Roč. 46, č. 5 (2009), s. 450-456 ISSN 0026-1394 R&D Projects: GA AV ČR IAA200650504; GA MŠk(CZ) LC06007; GA MŠk 2C06012; GA AV ČR KAN311610701; GA MPO 2A-1TP1/127; GA MPO FT-TA3/133 Institutional research plan: CEZ:AV0Z20650511 Keywords : laser stabilization * Nd :YAG laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.634, year: 2009

  8. Assessment of anxiety frequency and its trigger factors in patients referred to general dental offices in the city of Hamedan in 2005

    Directory of Open Access Journals (Sweden)

    Farhadinasab A.

    2008-10-01

    Full Text Available "nBackground and Aim: Oral health is a sign of overall health. Sometimes fear of dental office deprives  patients from receiving proper care. This problem decreases the self-esteem of dentists and can also reduce health indices. Understanding anxiety factors may help solve this problem. The purpose of this study was to assess anxiety in patients undergoing treatment in dental offices in the city of Hamedan. "nMaterials and Methods: In this analytic cross sectional study patients above 9 years old and referred to general dental offices in Hamedan were randomly selected and surveyed with questionnaires in two stages. The first questionnaire included 17 standard items based on Dental Anxiety Scale (DAS and screened anxious patients. Then 400 anxious patients were evaluated with a questionnaire of 64 items based on Corah scale. Data were analyzed by SPSS 13 with multivariate analysis of variance. P<0.05 was considered as the level of significance. "nResults: Factors related to dental office environment with 31.1%, those related to personal imaginations with 19.4% and factor concerning office management and dental treatment each with 19.1% frequency showed to be most related to anxiety in patients. Improper rest-rooms (46.3%, blood stains in the environment (44.5% and dirty dentist's gowns (43.8% were reported to be the most prominent environmental factors. Among the factors originated from personal imaginations, the risk of disease transmission was accounted for the most justifiable source of anxiety (67.3%. Regarding factors concerning office management, dentist's nervous behavior (47.8% and his carelessness to the patient (46.8% were considered as the most significant anxiety sources. Extraction, injection and root canal therapy (48.3%, 44.5%, 44.3% were the treatment related factors of higher importance respectively. Previous painful treatment experience (47.3% and poor oral hygiene of the dentist (34.5% were reported to be among the

  9. Cosmic backgrounds of relic gravitons and their absolute normalization

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    Provided the consistency relations are not violated, the recent Bicep2 observations pin down the absolute normalization, the spectral slope and the maximal frequency of the cosmic graviton background produced during inflation. The properly normalized spectra are hereby computed from the lowest frequencies (of the order of the present Hubble rate) up to the highest frequency range in the GHz region. Deviations from the conventional paradigm cannot be excluded and are examined by allowing for different physical possibilities including, in particular, a running of the tensor spectral index, an explicit breaking of the consistency relations and a spike in the high-frequency tail of the spectrum coming either from a post-inflationary phase dominated by a stiff fluid of from the contribution of waterfall fields in a hybrid inflationary context. The direct determinations of the tensor to scalar ratio at low frequencies, if confirmed by the forthcoming observations, will also affect and constrain the high-frequencies...

  10. Preliminary results of absolute wavelength calibration of imaging X-ray crystal spectrometer on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Xiayun [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Wang, Fudi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Chen, Jun [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Lyu, Bo, E-mail: blu@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Yingying; Fu, Jia; Xu, Liqing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Shi, Yuejiang [University of Science and Technology of China, Hefei 230026 (China); Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Ye, Minyou [University of Science and Technology of China, Hefei 230026 (China); Wan, Baonian [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2015-10-15

    Highlights: • The absolute wavelength calibration method for X-ray crystal spectrometer using X-ray fluorescence of the appropriate materials was first tested on EAST, and the preliminary experimental results were obtained. • The experimental results were thoroughly discussed and suggestion for further improvements of the experimental arrangement was proposed. • Rotation calibration of X-ray crystal spectrometer on EAST using MHD frequency was presented when the absolute wavelength calibration method is unavailable currently. - Abstract: Imaging X-ray crystal spectrometers (XCS) are currently operating on several major tokamaks to provide profiles of ion temperature and rotation velocity. In order to acquire absolute rotation velocity, several indirect methods were pursued previously, however the direct and effective method is to use known X-ray lines for wavelength calibration. One way to produce standard spectral lines is X-ray fluorescence, which could be excited by X-rays from tokamak plasmas. As part of the upgrade of XCS system on EAST, wavelength calibration was studied using cadmium's L-shell lines, namely Lα{sub 1} line (3.9564 Å) and Lα{sub 2} line (3.9650 Å) as the reference wavelength. The Geant 4 code was used to optimize foil thickness to achieve a reasonable X-ray fluorescence intensity. The Cd foil was placed between the beryllium window and crystal and could be retracted to provide in situ wavelength calibration. The detailed arrangement and preliminary wavelength calibration results of imaging X-ray crystal spectrometer on EAST are presented, plus the calibration using MHD frequency.

  11. Adjustment and testing comparison of absolute gravimeters in November 2013

    Directory of Open Access Journals (Sweden)

    Alena Pešková

    2017-07-01

    Full Text Available This paper is focused on a comparison measurement processing of absolute gravimeters in 2013. The comparison deals with a number of various types of absolute gravimeters and includes also an absolute gravimeter from Geodetic observatory Pecný. Comparative measurements are performed to detect systematic errors of gravimeters. A result of processing is most likely value of a gravity and a systematic error of individual devices. Measured values are input to a adjustment with condition a sum of systematic errors is zero. A part of this process is also verification following output: (i value of a posteriori standard deviation, (ii size of corrections and (iii statistical significance of systematic errors. The results of adjustment are 15 gravity values on the reference places and 25 systematic errors of measuring instruments. Result shows that the presence of systematic errors in measurements is not statistically provable because the systematic errors are similarly sized as their standard deviation.

  12. "Absolute" sterility and "absolute" freedom from particle contamination.

    Science.gov (United States)

    Knapp, J Z

    1998-01-01

    Until the recent past, sterility of an injectable product was only discussed in absolute terms. Any description of sterility other than as an absolute could simply not be envisioned. While dealing in absolute yes/no statements is philosophically satisfying, these yes/no statements can't accommodate all real world scientific problems. Among these problems is the sterility problems faced in the mass production of injectable compounds. Many descriptions of procedures employed to achieve sterility in parenteral production batches were reported in the literature. The theoretical framework that could unite the widespread observations and practices into practical methodology was missing until recently. Production line control of the sterility of injectable products was essentially based on gut evaluations. The present achievement of rational, production line control of product sterility is based on the recognition that product sterility could not be simply regarded as a sharply edged yes/no affair. The present rational control is based on the fact that the sterility of a product is determined by the degree of contamination in the product prior to sterilization and to the parameters of the sterilization process. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. The essential laboratory measurements on which this conclusion was based is due to Pflug (1-3). He assembled a theoretical framework, based on experimental data, that characterizes the sterility achieved in an injectable product with a single number. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. As in many disciplines, the ability to achieve an objective evaluation of this important attribute provided the basis for scientific analysis, improved control and thus improved production and reduced cost. An equivalent framework is essential for the communication and

  13. Auditory working memory predicts individual differences in absolute pitch learning.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Koch, Rachelle; Nusbaum, Howard C

    2015-07-01

    Absolute pitch (AP) is typically defined as the ability to label an isolated tone as a musical note in the absence of a reference tone. At first glance the acquisition of AP note categories seems like a perceptual learning task, since individuals must assign a category label to a stimulus based on a single perceptual dimension (pitch) while ignoring other perceptual dimensions (e.g., loudness, octave, instrument). AP, however, is rarely discussed in terms of domain-general perceptual learning mechanisms. This is because AP is typically assumed to depend on a critical period of development, in which early exposure to pitches and musical labels is thought to be necessary for the development of AP precluding the possibility of adult acquisition of AP. Despite this view of AP, several previous studies have found evidence that absolute pitch category learning is, to an extent, trainable in a post-critical period adult population, even if the performance typically achieved by this population is below the performance of a "true" AP possessor. The current studies attempt to understand the individual differences in learning to categorize notes using absolute pitch cues by testing a specific prediction regarding cognitive capacity related to categorization - to what extent does an individual's general auditory working memory capacity (WMC) predict the success of absolute pitch category acquisition. Since WMC has been shown to predict performance on a wide variety of other perceptual and category learning tasks, we predict that individuals with higher WMC should be better at learning absolute pitch note categories than individuals with lower WMC. Across two studies, we demonstrate that auditory WMC predicts the efficacy of learning absolute pitch note categories. These results suggest that a higher general auditory WMC might underlie the formation of absolute pitch categories for post-critical period adults. Implications for understanding the mechanisms that underlie the

  14. Absolute polarization determinations of 33 pulsars using the Green Bank Telescope

    Science.gov (United States)

    Force, Megan M.; Demorest, Paul; Rankin, Joanna M.

    2015-11-01

    Absolute polarimetry observations of 33 pulsars were carried out with the Green Bank Telescope in the 1100-1900 MHz band using the Green Bank Ultimate Pulsar Processing Instrument. This group was selected to help complete a larger sample for which accurate proper-motion measurements were available. A combination of profile analysis using the core/double cone model and polarization-angle fitting methods were applied to estimate the `fiducial' longitude of the magnetic axis for each star and refer the linear polarization angle at that point to infinite frequency. As had been found previously, a number of the pulsars are found to have fiducial polarization directions that fall either along or at right angles to their proper-motion directions, whereas upwards of a third of the stars studied show alignments that are neither parallel nor orthogonal.

  15. Absolute Wavelength Control of Lasers for Active Sensing in Space, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop compact absolute wavelength references to weak molecular transitions, which is a challenge characteristic to space-based active sensing. The...

  16. Regional neonatal brain absolute thermometry by 1H MRS.

    Science.gov (United States)

    Bainbridge, Alan; Kendall, Giles S; De Vita, Enrico; Hagmann, Cornelia; Kapetanakis, Andrew; Cady, Ernest B; Robertson, Nicola J

    2013-04-01

    Therapeutic hypothermia is standard care for infants with moderate to severe encephalopathy. (1) H MRS thermometry (MRSt) measures regional brain absolute temperature using the temperature-dependent water chemical shift. This study evaluates the clinical feasibility of MRSt in human neonates, and correlates white matter (WM) and thalamus (Thal) MRSt with conventional rectal temperature (Trectal ) measurement. Fifty-six infants born at term underwent perinatal MRSt for suspected hypoxic-ischaemic brain injury and 33 infants born preterm had MRSt at a term-equivalent age; 56 of the 89 had Trectal measured after MRSt of either a Thal or posterior WM voxel, or both. MRSt used point-resolved spectroscopy (no water suppression; TR = 1370 ms; TE = 288 ms; 1.5 × 1.5 × 1.5 cm(3) Thal and 1.1 × 1.3 × 1.4 cm(3) WM voxels). Time domain data were phase and frequency corrected before summation and motion-corrupted data were excluded from further analysis using simple criteria [preprocessing + quality assurance (QA)]. Two published water temperature-dependence calibrations [both using cerebral creatine (Cr), choline (Cho) and N-acetylaspartate (Naa) as independent reference peaks] were compared. The temperature measurements derived from Cr, Cho and Naa were combined to give a single amplitude-weighted combination temperature (TAWC ). WM and Thal TAWC correlated linearly with Trectal (Thal slope, 0.82 ± 0.04, R(2) = 0.85, p < 0.05; WM slope, 0.95 ± 0.04, R(2) = 0.78, p < 0.05). Preprocessing + QA improved the correlation between WM TAWC and Trectal (R(2) increased from 0.27 to 0.78, p < 0.001). Both calibration datasets showed specific inconsistencies between the temperatures calculated using Cr, Cho and Naa reference peaks when applied to this neonatal dataset. Neonatal MRSt is clinically feasible. Preprocessing + QA improved MRSt reliability in WM. The consideration of MRSt calibration internal biases is necessary before combining MRSt temperatures from multiple

  17. Making Astrology Scientific with Negative Absolute Temperature and Holography

    OpenAIRE

    Bartlett, Rodney

    2016-01-01

    This article was written after reading Astronomy magazine's column "Strange Universe" by Bob Berman. Toeing the traditional line of his fellow astronomers, he claims astrology is just a bit of fun, and that it has no scientific support. If we only focus on today's science, he's spot on - it has no support. But I refer to some science involving holograms and negative absolute temperatures to show that astrology would have scientific support in a new science based on cosmic unification, it w...

  18. Convective blueshifts in the solar atmosphere. I. Absolute measurements with LARS of the spectral lines at 6302 Å

    Science.gov (United States)

    Löhner-Böttcher, J.; Schmidt, W.; Stief, F.; Steinmetz, T.; Holzwarth, R.

    2018-03-01

    Context. The solar convection manifests as granulation and intergranulation at the solar surface. In the photosphere, convective motions induce differential Doppler shifts to spectral lines. The observed convective blueshift varies across the solar disk. Aim. We focus on the impact of solar convection on the atmosphere and aim to resolve its velocity stratification in the photosphere. Methods: We performed high-resolution spectroscopic observations of the solar spectrum in the 6302 Å range with the Laser Absolute Reference Spectrograph at the Vacuum Tower Telescope. A laser frequency comb enabled the calibration of the spectra to an absolute wavelength scale with an accuracy of 1 m s-1. We systematically scanned the quiet Sun from the disk center to the limb at ten selected heliocentric positions. The analysis included 99 time sequences of up to 20 min in length. By means of ephemeris and reference corrections, we translated wavelength shifts into absolute line-of-sight velocities. A bisector analysis on the line profiles yielded the shapes and convective shifts of seven photospheric lines. Results: At the disk center, the bisector profiles of the iron lines feature a pronounced C-shape with maximum convective blueshifts of up to -450 m s-1 in the spectral line wings. Toward the solar limb, the bisectors change into a "\\"-shape with a saturation in the line core at a redshift of +100 m s-1. The center-to-limb variation of the line core velocities shows a slight increase in blueshift when departing the disk center for larger heliocentric angles. This increase in blueshift is more pronounced for the magnetically less active meridian than for the equator. Toward the solar limb, the blueshift decreases and can turn into a redshift. In general, weaker lines exhibit stronger blueshifts. Conclusions: Best spectroscopic measurements enabled the accurate determination of absolute convective shifts in the solar photosphere. We convolved the results to lower spectral

  19. Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: Theoretical assessment of the induced electric fields

    NARCIS (Netherlands)

    J. Bakker (Jan); M.M. Paulides (Maarten); E. Neufeld; A. Christ (A.); X.C. Chen (X. C.); N. Kuster (Niels); G.C. van Rhoon (Gerard)

    2012-01-01

    textabstractTo avoid potentially adverse health effects, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined reference levels for time varying magnetic fields. Restrictions on the electric fields induced in the human body are provided based on biological response

  20. Neural sensitivity to absolute and relative anticipated reward in adolescents.

    Directory of Open Access Journals (Sweden)

    Jatin G Vaidya

    Full Text Available Adolescence is associated with a dramatic increase in risky and impulsive behaviors that have been attributed to developmental differences in neural processing of rewards. In the present study, we sought to identify age differences in anticipation of absolute and relative rewards. To do so, we modified a commonly used monetary incentive delay (MID task in order to examine brain activity to relative anticipated reward value (neural sensitivity to the value of a reward as a function of other available rewards. This design also made it possible to examine developmental differences in brain activation to absolute anticipated reward magnitude (the degree to which neural activity increases with increasing reward magnitude. While undergoing fMRI, 18 adolescents and 18 adult participants were presented with cues associated with different reward magnitudes. After the cue, participants responded to a target to win money on that trial. Presentation of cues was blocked such that two reward cues associated with $.20, $1.00, or $5.00 were in play on a given block. Thus, the relative value of the $1.00 reward varied depending on whether it was paired with a smaller or larger reward. Reflecting age differences in neural responses to relative anticipated reward (i.e., reference dependent processing, adults, but not adolescents, demonstrated greater activity to a $1 reward when it was the larger of the two available rewards. Adults also demonstrated a more linear increase in ventral striatal activity as a function of increasing absolute reward magnitude compared to adolescents. Additionally, reduced ventral striatal sensitivity to absolute anticipated reward (i.e., the difference in activity to medium versus small rewards correlated with higher levels of trait Impulsivity. Thus, ventral striatal activity in anticipation of absolute and relative rewards develops with age. Absolute reward processing is also linked to individual differences in Impulsivity.

  1. Intracortical myelination in musicians with absolute pitch: Quantitative morphometry using 7‐T MRI

    Science.gov (United States)

    Knösche, Thomas R.

    2016-01-01

    Abstract Absolute pitch (AP) is known as the ability to recognize and label the pitch chroma of a given tone without external reference. Known brain structures and functions related to AP are mainly of macroscopic aspects. To shed light on the underlying neural mechanism of AP, we investigated the intracortical myeloarchitecture in musicians with and without AP using the quantitative mapping of the longitudinal relaxation rates with ultra‐high‐field magnetic resonance imaging at 7 T. We found greater intracortical myelination for AP musicians in the anterior region of the supratemporal plane, particularly the medial region of the right planum polare (PP). In the same region of the right PP, we also found a positive correlation with a behavioral index of AP performance. In addition, we found a positive correlation with a frequency discrimination threshold in the anterolateral Heschl's gyrus in the right hemisphere, demonstrating distinctive neural processes of absolute recognition and relative discrimination of pitch. Regarding possible effects of local myelination in the cortex and the known importance of the anterior superior temporal gyrus/sulcus for the identification of auditory objects, we argue that pitch chroma may be processed as an identifiable object property in AP musicians. Hum Brain Mapp 37:3486–3501, 2016. © 2016 Wiley Periodicals, Inc. PMID:27160707

  2. Intracortical myelination in musicians with absolute pitch: Quantitative morphometry using 7-T MRI.

    Science.gov (United States)

    Kim, Seung-Goo; Knösche, Thomas R

    2016-10-01

    Absolute pitch (AP) is known as the ability to recognize and label the pitch chroma of a given tone without external reference. Known brain structures and functions related to AP are mainly of macroscopic aspects. To shed light on the underlying neural mechanism of AP, we investigated the intracortical myeloarchitecture in musicians with and without AP using the quantitative mapping of the longitudinal relaxation rates with ultra-high-field magnetic resonance imaging at 7 T. We found greater intracortical myelination for AP musicians in the anterior region of the supratemporal plane, particularly the medial region of the right planum polare (PP). In the same region of the right PP, we also found a positive correlation with a behavioral index of AP performance. In addition, we found a positive correlation with a frequency discrimination threshold in the anterolateral Heschl's gyrus in the right hemisphere, demonstrating distinctive neural processes of absolute recognition and relative discrimination of pitch. Regarding possible effects of local myelination in the cortex and the known importance of the anterior superior temporal gyrus/sulcus for the identification of auditory objects, we argue that pitch chroma may be processed as an identifiable object property in AP musicians. Hum Brain Mapp 37:3486-3501, 2016. © 2016 Wiley Periodicals, Inc. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.

  3. Study of the Frequency of Specific Low Back Pain and the Factors Affecting on thePatients Referring to Clinics of Shahid Sadoughi Hospital

    OpenAIRE

    Mohammad Reza Sobhan; Seyyed Mohammadjalil Abrisham; Mohammad Ghoraishian; Masoud Heidarnejad; Mina Khorshidi

    2017-01-01

    Introduction: Low back pain is the most common reason for all physician visits and many people experience it during their life. The reason for this study was to show the frequency analysis of the causes of back pain and  analyzing their association with some clinical and demographic findings. Methods: This analytic cross sectional study was performed on the patients visited in the Clinics of Yazd Shahid Sadoughi Hospital in 2013. Patients with low back pain due to paraclinical finding...

  4. Preliminary investigation of the roles of military background and posttraumatic stress symptoms in frequency and recidivism of intimate partner violence perpetration among court-referred men.

    Science.gov (United States)

    Hoyt, Tim; Wray, Alisha M; Rielage, Jennifer Klosterman

    2014-04-01

    Significant rates of intimate partner violence (IPV) perpetration have been identified among men with military backgrounds. Research indicates posttraumatic stress symptoms place military men at increased risk for IPV perpetration, but may be negatively associated with IPV among nonmilitary samples. However, no previous studies have directly compared court-referred IPV offenders with and without military experience, which may have clinical implications if posttraumatic stress symptoms are differentially associated with IPV perpetration across these two samples. Twenty court-referred IPV offenders with military background were demographically matched with 40 court-referred IPV offenders without military background. As anticipated, self- and partner-report of physically assaultive acts and injurious acts during baseline assessment showed significantly greater physical assault and injury perpetrated by offenders with military background. However, 1-year follow-up data on convictions indicated a significantly lower rate of recidivism among offenders with military background than among nonmilitary offenders. As hypothesized, symptoms of posttraumatic stress at intake showed a significant positive correlation with IPV perpetration among offenders with military background; however, this relationship showed a negative correlation among offenders without military background. Clinical implications are discussed including treatment avenues, such as Veterans Courts and other incarceration diversion programs, which may be particularly appropriate for offenders with military backgrounds.

  5. Absolute and Functional Iron Deficiency Anemia among Different Tumors in Cancer Patients in South Part of Iran, 2014

    Science.gov (United States)

    Hashemi, Seyed Mehdi; Mashhadi, Mohammad Ali; Mohammadi, Mehdi; Ebrahimi, Maryam; Allahyari, Abolghasem

    2017-01-01

    Background: Anemia is a common problem in cancer patients. This study aimed to investigate the frequency rate of absolute and functional iron deficiency anemia among different tumors and its distribution in different stages of cancer in solid tumors. Materials and Methods: This study was performed on 597 patients with cancer referred to Ali-Ebne-Abitaleb Hospital in Zahedan. Laboratory tests included serum iron, transferrin saturation, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and complete blood count (CBC). The malignancy type and stages were recorded. Data were analysed using SPSS statistics software (Ver.19). Results: Four hundred and fifty-seven patients (76.5 %) diagnosed with solid tumors and 140 (23.5%) suffered from hematologic malignancies. Among patients with solid tumors, functional iron deficiency had the highest rate (300 patients had anemia and 243 (53.2%) of whom were functionally iron deficient), but in hematologic malignancies most of patients had not iron deficiency (66 patients had not iron deficiency against 12 patients had absolute iron deficiency and 62 patients had functional iron deficiency anemia) (P-value=0.021). No significant differences were observed among the various stages of cancers in terms of degrees of iron deficiency (P>0.05). Conclusion: The results of the study showed that solid tumors had a higher rate of absolute and functional iron deficiency anemia, compared to hematologic malignancies. But there was no difference between the different stages of the disease. PMID:28989585

  6. Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: theoretical assessment of the induced electric fields

    Science.gov (United States)

    Bakker, J. F.; Paulides, M. M.; Neufeld, E.; Christ, A.; Chen, X. L.; Kuster, N.; van Rhoon, G. C.

    2012-04-01

    To avoid potentially adverse health effects, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined reference levels for time varying magnetic fields. Restrictions on the electric fields induced in the human body are provided based on biological response data for peripheral nerve stimulation and the induction of phosphenes. Numerical modeling is commonly used to assess the induced electric fields for various exposure configurations. The objective of this study was to assess the variations of the electric fields induced in children and adults and to compare the exposure at reference levels with the basic restrictions as function of anatomy. We used the scalar potential finite element method to calculate the induced electric fields in six children and two adults when exposed to uniform magnetic fields polarized in three orthogonal directions. We found that the induced electric fields are within the ICNIRP basic restrictions in nearly all cases. In PNS tissues, we found electric fields up to 95% (upper uncertainty limit due to discretization errors, k = 2) of the ICNIRP basic restrictions for exposures at the general public reference levels. For occupational reference levels, we found an over-exposure of maximum 79% (k = 2) in PNS tissues. We further found that the ICNIRP recommendations on spatial averaging in 2 × 2 × 2 mm3 contiguous tissue volumes and removal of peak values by the 99th percentile cause the results to depend strongly on the grid discretization step (i.e. an uncertainty of more than 50% at 2 mm) and the number of distinguished tissues in the anatomical models. The computational results obtained by various research institutes should be robust for different discretization settings and various anatomical models. Therefore, we recommend considering alternative routines for small anatomical structures such as non-contiguous averaging without taking the 99th percentile in future guidelines leading to consistent

  7. Absolutely summing multilinear operators: a Panorama | Pellegrino ...

    African Journals Online (AJOL)

    This paper has a twofold purpose: to present an overview of the theory of absolutely summing operators and its different generalizations for the multilinear setting, and to sketch the beginning of a research project related to an objective search of “perfect” multilinear extensions of the ideal of absolutely summing operators.

  8. MEAN OF MEDIAN ABSOLUTE DERIVATION TECHNIQUE MEAN ...

    African Journals Online (AJOL)

    eobe

    The accurate estimation of noise variance in an image is the first important stage ... lung image was lung image was developed. developed. developed. The development of mean of median absolute derivation technique development of mean of median absolute .... that are non-real numbers during initial processing.

  9. Quantum nonequilibrium equalities with absolute irreversibility

    Science.gov (United States)

    Funo, Ken; Murashita, Yûto; Ueda, Masahito

    2015-07-01

    We derive quantum nonequilibrium equalities in absolutely irreversible processes. Here by absolute irreversibility we mean that in the backward process the density matrix does not return to the subspace spanned by those eigenvectors that have nonzero weight in the initial density matrix. Since the initial state of a memory and the postmeasurement state of the system are usually restricted to a subspace, absolute irreversibility occurs during the measurement and feedback processes. An additional entropy produced in absolutely irreversible processes needs to be taken into account to derive nonequilibrium equalities. We discuss a model of a feedback control on a qubit system to illustrate the obtained equalities. By introducing N heat baths each composed of a qubit and letting them interact with the system, we show how the entropy reduction via feedback control can be converted into work. An explicit form of extractable work in the presence of absolute irreversibility is given.

  10. Survey of doses and frequency of X-ray examinations on children at the intensive care unit of a large reference pediatric hospital

    International Nuclear Information System (INIS)

    Pedrosa de Azevedo, Ana Cecilia; Osibote, Adelaja Otolorin; Bastos Boechat, Marcia Cristina

    2006-01-01

    Objective: This work aims to evaluate the entrance surface dose (ESD), the body organ dose (BOD) and the effective dose (E) resulting from pediatric radiological procedures with the use of portable X-ray equipments. Materials and methods: The software DoseCal was used to evaluate the doses imparted to patients. The children were classified according to their weight and age groups, and the study included three sectors of the intensive care unit of a large reference pediatric hospital in Rio de Janeiro. Results: A total of 518 radiographs have been performed (424 for chest and 94 for abdomen). The statistical data were compared with previously published results. The BOD is presented for the most exposed organs. Conclusion: The mean value of ESD and E varied widely among neonates. The highest number of radiographs per infant peaked 33 for chest examination in the age group 0-1 year

  11. The PMA Catalogue: 420 million positions and absolute proper motions

    Science.gov (United States)

    Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.

    2017-07-01

    We present a catalogue that contains about 420 million absolute proper motions of stars. It was derived from the combination of positions from Gaia DR1 and 2MASS, with a mean difference of epochs of about 15 yr. Most of the systematic zonal errors inherent in the 2MASS Catalogue were eliminated before deriving the absolute proper motions. The absolute calibration procedure (zero-pointing of the proper motions) was carried out using about 1.6 million positions of extragalactic sources. The mean formal error of the absolute calibration is less than 0.35 mas yr-1. The derived proper motions cover the whole celestial sphere without gaps for a range of stellar magnitudes from 8 to 21 mag. In the sky areas where the extragalactic sources are invisible (the avoidance zone), a dedicated procedure was used that transforms the relative proper motions into absolute ones. The rms error of proper motions depends on stellar magnitude and ranges from 2-5 mas yr-1 for stars with 10 mag < G < 17 mag to 5-10 mas yr-1 for faint ones. The present catalogue contains the Gaia DR1 positions of stars for the J2015 epoch. The system of the PMA proper motions does not depend on the systematic errors of the 2MASS positions, and in the range from 14 to 21 mag represents an independent realization of a quasi-inertial reference frame in the optical and near-infrared wavelength range. The Catalogue also contains stellar magnitudes taken from the Gaia DR1 and 2MASS catalogues. A comparison of the PMA proper motions of stars with similar data from certain recent catalogues has been undertaken.

  12. Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

    Science.gov (United States)

    Kubalak, David; Hadjimichael, Theodore; Ohl, Raymond; Slotwinski, Anthony; Telfer, Randal; Hayden, Joseph

    2012-01-01

    Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a

  13. The absolute environmental performance of buildings

    DEFF Research Database (Denmark)

    Brejnrod, Kathrine Nykjær; Kalbar, Pradip; Petersen, Steffen

    2017-01-01

    sustainability for the standard house were proposed focusing on three measures: minimizing environmental impacts from building construction, minimizing impacts from energy consumption during use phase, and reducing the living area per person. In an intermediate path, absolute sustainability can be obtained...... by reducing the impacts from construction by 89%, use phase energy consumption by 80%, and the living area by 60%.......Our paper presents a novel approach for absolute sustainability assessment of a building's environmental performance. It is demonstrated how the absolute sustainable share of the earth carrying capacity of a specific building type can be estimated using carrying capacity based normalization factors...

  14. Frequency of fall-related injuries of female patients referred to the trauma center in the city of Kashan from years 2005 to 2008

    Directory of Open Access Journals (Sweden)

    Sayyah Mansour

    2013-02-01

    Full Text Available 【Abstract】 Objective: Falls are one of the life events leading to injury and in serious cases cause high morbidity and mortality. This research was conducted to determine the fall incidence among female population of Kashan city from the years 2005 to 2008. Methods: This was a retrospective research using existing data from the data bank of trauma center of Kashan University of Medical Sciences. Records of all the female patients treated at local hospitals with complete hospitalisation kept at the center were examined for 4 con-secutive years from 2005 to 2008. Results: A total of 2 094 female patients’ records were examined. A significantly higher incidence of injuy occurred in 2008 compared to 2005 (P<0.0001. In addition, the highest frequency of injury occurred in age group above 65 years (31.9% and in group with elementary education level (42.8%. Conclusion: The results showed that fall incidences occurred in the old age group above 65 years. Fall injuries at this age may cause disability. Therefore, preventive mea-sures should be taken, such as increasing the awareness of the aging population about the seriousness of fall incidence and encouraging the aged individuals to get involved in fitness program to remain physical fit and healthy. Key words: Accidental falls; Wounds and injuries; Female

  15. Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Shafer, R. A.; Eplee, R. E.; Isaacman, R. B.; Fixsen, D. J.; Read, S. M.; Meyer, S. S.; Weiss, R.; Wright, E. L.

    1991-01-01

    The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.

  16. ASTEROID ABSOLUTE MAGNITUDES V10.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2006 March 14 batch of Minor Planet Circulars.

  17. ASTEROID ABSOLUTE MAGNITUDES V11.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2007 April 2 batch of Minor Planet Circulars.

  18. ASTEROID ABSOLUTE MAGNITUDES V12.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2008 April 20 batch of Minor Planet Circulars.

  19. ASTEROID ABSOLUTE MAGNITUDES V7.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set tabulates the IAU-adopted absolute V magnitude and slope parameter for all numbered asteroids as of the given stop date. The data set is updated yearly.

  20. ASTEROID ABSOLUTE MAGNITUDES V9.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2005 April 7 batch of Minor Planet Circulars.

  1. ASTEROID ABSOLUTE MAGNITUDES V8.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2004 April 15 batch of Minor Planet Circulars

  2. Absolutely uniform illumination of laser fusion pellets

    International Nuclear Information System (INIS)

    Schmitt, A.J.

    1984-01-01

    Absolutely uniform illumination of spherical laser fusion pellets is possible when the energy deposition from a single beam is given by a simple cos 2 theta distribution. Conditions can be derived for which the laser beam targeting angles allow this absolute illumination uniformity. Configurations based upon the cube and higher order Platonic solids satisfy the constraints, as well as an infinite class of other less symmetric configurations

  3. Absolutely uniform illumination of laser fusion pellets

    International Nuclear Information System (INIS)

    Schmitt, A.J.

    1984-01-01

    Absolutely uniform illumination of spherical laser fusion pellets is possible when the energy deposition from a single laser beam is given by a simple cos 2 theta distribution. Conditions can be derived for which the laser beam targeting angles allow this absolute illumination uniformity. Configurations based upon the cube and higher order Platonic solids satisfy the constraints, as well as infinite class of other less symmetric configurations

  4. Absolute distance measurements using two-mode laser telemetry

    Science.gov (United States)

    Lintz, Michel.; Courde, C.; Brillet, A.; Man, C. N.

    2017-11-01

    A novel laser ranging method is described that uses a two-mode laser source, and detection of the phase of the return beam. The design eliminates the cyclic error usually associated with phase measurements and provides unambiguous, absolute distance determination. Measurements of an ≍ 8m path are obtained at a beat frequency of 13 GHz. We analyse the ≍1 μm stability of the data obtained with this preliminary implementation, and expect that an improved version will allow accuracies well below 1 μm, for the kilometer-scale distances involved in satellite formation flight.

  5. Elementary, Middle, and High School Students Vary in Frequency and Purpose When Using Online Digital References. A review of: Silverstein, Joanne. “Just Curious: Children’s Use of Digital Reference for Unimposed Queries and Its Importance in Informal Education.” Library Trends 54.2 (Fall 2005: 228‐44.

    Directory of Open Access Journals (Sweden)

    Julie Stephens

    2006-12-01

    Full Text Available Objective – To determine 1 how and with what frequency children use digital references to answer their own unimposed questions; 2 whether digital reference services support their self‐initiated learning; 3 whether digital reference services support the transfer of student motivation and curiosity from the formal to the informal; and 4 what instructional and software designers should consider in creating tools that support learning.Design – Inductive analysis.Setting – Virtual Reference Desk’s (VRD Learning Center (http://vrd.askvrd.org/ and the National Science Foundation’s (NSFdigital reference service (http://www.esteme.org during Excellence in Science, Technology, Engineering, and Mathematics Education Week (ESTEME, April 11‐16, 2005.Subjects – Elementary (K‐5, middle (6‐8,and high school (9‐12 students from the general public. One hundred fourteen questions were analyzed, however there is no indication of the number of different students who submitted the questions.Methods – This study was conducted using a pool of 600 questions from students, teachers, parents, and the general public that were submitted to two digital reference services intended for students. Three hundred experts in the fields of Math and Science volunteered to answer the submitted questions during Excellence in Science, Technology, Engineering, and Mathematics Education Week. Because the digital services employed a pull‐down menu to describe the user as a student, teacher, parent, etc., the questions could be narrowed to those submitted by students. The questions were also narrowed to those marked as “just curious” from a question purpose menu that contained categories including “written report,” “science fair project,” and “just curious.” A total of 114 unique questions from elementary, middle, and high school students were analyzed to determine the study objectives. The 114 questions were loaded into a qualitative software

  6. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    Directory of Open Access Journals (Sweden)

    Sammie eTarenskeen

    2015-11-01

    Full Text Available The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a between-participants design, however, we find similar rates of pattern and size overspecification, which are both lower than the rate of colour overspecification. This indicates that although many speakers are more likely to include colour than pattern (probably because colour is more salient, they may also treat pattern like colour due to a tendency towards consistency. We find no increase in size overspecification when the salience of size is increased, suggesting that speakers are more likely to include absolute than relative attributes. However, we do find an increase in size overspecification when mentioning the attributes is triggered, which again shows that speakers tend refer in a consistent manner, and that there are circumstances in which even size overspecification is frequently produced.

  7. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  8. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    Science.gov (United States)

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed.

  9. Application of x-ray fluorescence (XRF) absolute analysis method for silica refractories

    International Nuclear Information System (INIS)

    Asakura, Hideo; Yamada, Yasujiro; Kansai, Kouhei; Tomatsu, Ichirou; Murata, Mamoru

    2015-01-01

    X-ray fluorescence (XRF) analysis is a rapid and precise quantitative analytical method for the determination of major and trace elements in many industries and academics. XRF analytical values are relative due to the use of the calibration curves calculated from measuring the reference standard materials such as Japanese Refractory Reference Materials (JRRM) series with certified values determined by wet chemical analysis. The development of the XRF analytical method from relative to absolute analysis will help much to determine the absolute values of samples from the fields where reference standard samples have not been prepared, and thus can be applied widely in many industries. The implement of the absolute XRF analysis for silica refractories requires high purity reagents and/or reference standard solution for the binary basic calibration curve, and theoretical matrix correction coefficients for the multi-components silica refractories analysis. The reproducibility and repeatability of this method for Al 2 O 3 5 mass% sample were 0.009 and 0.006 mass% in Al 2 O 3 and showed better values that those of ICP-AES recognized as an absolute method in JIS R 2212-2, which yielded 0.028 and 0.031 mass%, respectively. The XRF absolute analysis for JRRM 200 series, 201a and 205a does not show a bias but coincides with their certified values. (author)

  10. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  11. The Absolute Normal Scores Test for Symmetry

    Science.gov (United States)

    Penfield, Douglas A.; Sachdeva, Darshan

    1976-01-01

    The absolute normal scores test is described as a test for the symmetry of a distribution of scores about a location parameter. The test is compared to the sign test and the Wilcoxon test as an alternative to the "t"-test. (Editor/RK)

  12. The Theory of Absolute Reaction Rates

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 7. The Theory of Absolute Reaction Rates. Henry Eyring. Classics Volume 17 Issue 7 July 2012 pp 704-711. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/017/07/0704-0711. Author Affiliations.

  13. 49 CFR 236.709 - Block, absolute.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Block, absolute. 236.709 Section 236.709 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION...

  14. Thin-film magnetoresistive absolute position detector

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1990-01-01

    The subject of this thesis is the investigation of a digital absolute posi- tion-detection system, which is based on a position-information carrier (i.e. a magnetic tape) with one single code track on the one hand, and an array of magnetoresistive sensors for the detection of the information on the

  15. Det demokratiske argument for absolut ytringsfrihed

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2014-01-01

    Artiklen diskuterer den påstand, at absolut ytringsfrihed er en nødvendig forudsætning for demokratisk legitimitet med udgangspunkt i en rekonstruktion af et argument fremsat af Ronald Dworkin. Spørgsmålet er, hvorfor ytringsfrihed skulle være en forudsætning for demokratisk legitimitet, og hvorf...

  16. Absolute Distance Measurements with Tunable Semiconductor Laser

    Czech Academy of Sciences Publication Activity Database

    Mikel, Břetislav; Číp, Ondřej; Lazar, Josef

    T118, - (2005), s. 41-44 ISSN 0031-8949 R&D Projects: GA AV ČR(CZ) IAB2065001 Keywords : tunable laser * absolute interferometer Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  17. Stimulus Probability Effects in Absolute Identification

    Science.gov (United States)

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  18. systemic complications following absolute alcohol embolisation of ...

    African Journals Online (AJOL)

    of the superficial temporal (STA), middle meningeal. (MMA) and occipital ... external jugular vein. Absolute alcohol was injected into the feeder artery using the intermittent pulsed spray technique in aliquots of 1 ml. A total of 55 ml of alcohol was injected. ... cells, vessel wall necrosis resulting in thrombosis and permanent ...

  19. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  20. Absolute tightness: the chemists hesitate to invest

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The safety requirements of industries as nuclear plants and the strengthening of regulations in the field of environment (more particularly those related to volatile organic compounds) have lead the manufacturers to build absolute tightness pumps. But these equipments do not answer all the problems and represent a high investment cost. In consequence, the chemists hesitate to invest. (O.L.)

  1. Absolute chronology and stratigraphy of Lepenski Vir

    Directory of Open Access Journals (Sweden)

    Borić Dušan

    2007-01-01

    Full Text Available In the last decade, a number of specialist analyses were made on the material from old excavations of Mesolithic-Neolithic sites in the Danube Gorges. These new results altered significantly our understanding of the Lepenski Vir culture. The question of chronology of this regional phenomenon has been acute since the discovery of Lepenski Vir in the 1960s, and it remains of key importance for understanding the character of Mesolithic-Neolithic transformations in this and the neighbouring regions. The most heated debate was fuelled by the initial stratigraphic and chronological attribution of the type-site itself. There remained the question about the adequate dating of the most prominent phase at this site characterized by buildings with trapezoidal bases covered with limestone floors and with rectangular stone-lined hearths placed in the centre of these features. There have been suggestions that these features also contain Early Neolithic Starčevo type pottery and other similar items of material culture and should thus be dated to the Early Neolithic historical context. Moreover, the first series of conventional radiocarbon determinations (21 dates also suggested that the absolute chronology of these features should be confined to the period from around 6400-5500 cal BC (Fig. 1. Due to the importance of defining more precisely the chronology for the start of construction of these particular features at Lepenski Vir and for establishing the life-span of these buildings and their associated material culture, we have AMS (Accelerator Mass Spectrometry dated a number of contexts from this site. The results are presented in this paper. The project was made possible through the Oxford Radiocarbon Accelerate Dating Service (ORADS programme funded by the Arts and Humanities Research Council (AHRC and the Natural Environment Research Council (NERC of the Great Britain. Apart from those dates presented in this paper, there are 29 previously published

  2. The Absolute Shielding Constants of Heavy Nuclei: Resolving the Enigma of the (119)Sn Absolute Shielding.

    Science.gov (United States)

    Malkin, Elena; Komorovsky, Stanislav; Repisky, Michal; Demissie, Taye B; Ruud, Kenneth

    2013-02-07

    We demonstrate that the apparent disagreement between experimental determinations and four-component relativistic calculations of the absolute shielding constants of heavy nuclei is due to the breakdown of the commonly assumed relation between the electronic contribution to the nuclear spin-rotation constants and the paramagnetic contribution to the NMR shielding constants. We demonstrate that this breakdown has significant consequences for the absolute shielding constant of (119)Sn, leading to errors of about 1000 ppm. As a consequence, we expect that many absolute shielding constants of heavy nuclei will be in need of revision.

  3. Consequences count: against absolutism at the end of life.

    Science.gov (United States)

    Snelling, Paul C

    2004-05-01

    There has been a considerable amount of debate in the nursing literature about euthanasia, and especially the distinctions between acts and omissions, and killing and letting die. These distinctions are required by opponents of euthanasia to justify allowing some cases of passive euthanasia while forbidding all cases of active euthanasia. This paper adds to the debate by arguing that the position that absolutely forbids euthanasia is theoretically inconsistent. The paper first considers the place of moral theory in analysing moral problems, within the framework of the principles of biomedical ethics. It is argued that despite a moral pluralism that operates in many areas, the legal status of euthanasia is based upon an absolute deontological position against deliberate killing, which cannot be overridden by appeals to favourable consequences. In order that certain forms of passive euthanasia can be allowed, this position allows distinctions within three pairs of concepts--acts and omissions, killing and letting die, and ordinary and extraordinary means. A further method of justifying certain actions near the end of life is the doctrine of double effect. These paired concepts and the doctrine of double effect are analysed with special reference to their consequences. The application of the doctrine of double effect and the three distinctions relies on consideration of their consequences, allowing in practice what in theory is denied. This is important because it weakens the absolute case against euthanasia, which disallows any direct consequentialist appeal. If consequences count in the application of the doctrine and the distinctions, then they should also count directly prior to their application. This strengthens the argument for active euthanasia in certain cases.

  4. Absolute versus relative ascertainment of pedophilia in men.

    Science.gov (United States)

    Blanchard, Ray; Kuban, Michael E; Blak, Thomas; Cantor, James M; Klassen, Philip E; Dickey, Robert

    2009-12-01

    There are at least two different criteria for assessing pedophilia in men: absolute ascertainment (their sexual interest in children is intense) and relative ascertainment (their sexual interest in children is greater than their interest in adults). The American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, 3rd edition (DSM-III) used relative ascertainment in its diagnostic criteria for pedophilia; this was abandoned and replaced by absolute ascertainment in the DSM-III-R and all subsequent editions. The present study was conducted to demonstrate the continuing need for relative ascertainment, particularly in the laboratory assessment of pedophilia. A total of 402 heterosexual men were selected from a database of patients referred to a specialty clinic. These had undergone phallometric testing, a psychophysiological procedure in which their penile blood volume was monitored while they were presented with a standardized set of laboratory stimuli depicting male and female children, pubescents, and adults.The 130 men selected for the Teleiophilic Profile group responded substantially to prepubescent girls but even more to adult women; the 272 men selected for the Pedophilic Profile group responded weakly to prepubescent girls but even less to adult women. In terms of absolute magnitude, every patient in the Pedophilic Profile group had a lesser penile response to prepubescent girls than every patient in the Teleiophilic Profile group. Nevertheless, the Pedophilic Profile group had a significantly greater number of known sexual offenses against prepubescent girls, indicating that they contained a higher proportion of true pedophiles. These results dramatically demonstrate the utility-or perhaps necessity-of relative ascertainment in the laboratory assessment of erotic age-preference.

  5. ARCADE 2 MEASUREMENT OF THE ABSOLUTE SKY BRIGHTNESS AT 3-90 GHz

    International Nuclear Information System (INIS)

    Fixsen, D. J.; Kogut, A.; Wollack, E.; Levin, S.; Seiffert, M.; Limon, M.; Lubin, P.; Mirel, P.; Singal, J.; Villela, T.; Wuensche, C. A.

    2011-01-01

    The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an in situ reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the cosmic microwave background (CMB) temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an excess radio rise of 54 ± 6 mK at 3.3 GHz in addition to a CMB temperature of 2.731 ± 0.004 K. Combining the ARCADE 2 data with data from the literature shows an excess power-law spectrum of T = 24.1 ± 2.1 (K) (ν/ν 0 ) -2.599±0.036 from 22 MHz to 10 GHz (ν 0 = 310 MHz) in addition to a CMB temperature of 2.725 ± 0.001 K.

  6. From direct to absolute mass measurements a study of the accuracy of ISOLTRAP

    CERN Document Server

    Kellerbauer, A G; Bollen, G; Herfurth, F; Kluge, H J; Kuckein, M; Sauvan, E; Scheidenberger, C; Schweikhard, L

    2003-01-01

    For a detailed study of the accuracy of the Penning trap mass spectrometer ISOLTRAP all expected sources of uncertainty were investigated with respect to their contributions to the uncertainty of the final result. In the course of these investigations, cross-reference measurements with singly charged carbon clusters $^{12}$C$^{+}_{n}$ were carried out. The carbon cluster ions were produced by use of laser-induced desorption, fragmentation, and ionization of C$_{60}$ fullerenes and injected into and stored in the Penning trap system. The comparison of the cyclotron frequencies of different carbon clusters has provided detailed insight into the residual systematic uncertainty of \\acro{ISOLTRAP} and yielded a value of $8 \\cdot 10^{-9}$. This also represents the current limit of mass accuracy of the apparatus. Since the unified atomic mass unit is defined as 1/12 of the mass of the $^{12}$C atom, it will be possible to carry out absolute mass measurements with \\acro{ISOLTRAP} in the future.\\\\[1\\baselineskip] PACS...

  7. Enhancement of speech-relevant auditory acuity in absolute pitch possessors

    Directory of Open Access Journals (Sweden)

    Nobuo eMasataka

    2011-05-01

    Full Text Available AbstractAbsolute pitch (AP is the ability to identify the frequency or musical name of a specific tone, or to identify a tone without comparing it with any objective reference tone. While AP has recently been shown to be associated with morphological changes and neurophysiological adaptations in the planum temporale, a cortical area in the brain involved in speech perception processes, no behavioral evidence of speech-relevant auditory acuity in any AP possessors has hitherto been reported. In order to seek such evidence, in the present study, 15 professional musicians with AP and 14 without AP, all of whom had acquired Japanese as their first language, were asked to identify isolated Japanese syllables as quickly as possible after these syllables were presented auditorily. When the mean latency to the syllable identification was compared, it was significantly shorter in AP possessors than in non-AP possessors whether the presented syllables were those used as Japanese labels representing the 7 tones constituting an octave or not. The latency to hear the stimuli per se did not differ according to whether the participants were AP possessors or not. The results indicate the possibility that possessing AP provides one with extraordinarily enhanced acuity to individual syllables per se as fundamental units of a segmented word in the speech stream.

  8. From Hubble's NGSL to Absolute Fluxes

    Science.gov (United States)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  9. Trapped individual ion at absolute zero temperature

    Science.gov (United States)

    Yu, Nan; Dehmelt, Hans; Nagourney, Warren

    1989-01-01

    Laser cooling and ion trapping have progressed to such an extent that one can now speak of realizing a confined atom at absolute zero temperature. In this short publication, we analyze an experiment toward such realization using a single Ba+ ion in a miniature rf trap. The Ba+ ion is first laser-cooled to the limit where the ion spends most of its time in the zero-point energy state. Then a test sequence allows one to verify whether or not the ion is actually in its zero-point state. The test sequence may also serve as a device for state selection of an atom at absolute zero temperature. PMID:16594054

  10. Information structure and reference tracking in complex sentences

    CERN Document Server

    Gijn, Rik van; Matic, Dejan

    2014-01-01

    This paper discusses argument marking and reference tracking in Mekens complex clauses and their correlation to information structure. The distribution of pronominal arguments in Mekens simple clauses follows an absolutive pattern with main verbs. Complex clauses maintain the morphological absolutive argument marking, but show a nominative pattern with respect to argument reference tracking, since transitive and intransitive subjects function as syntactic pivots. The language extends the use of argument-marking verb morphology to control the reference of discourse participants across clauses.

  11. Interpolation of uniformly absolutely continuous operators

    Czech Academy of Sciences Publication Activity Database

    Cobos, F.; Gogatishvili, Amiran; Opic, B.; Pick, L.

    2013-01-01

    Roč. 286, 5-6 (2013), s. 579-599 ISSN 0025-584X R&D Projects: GA ČR GA201/08/0383 Institutional support: RVO:67985840 Keywords : uniformly absolutely continuous operators * interpolation * type of an interpolation method Subject RIV: BA - General Mathematics Impact factor: 0.658, year: 2013 http://onlinelibrary.wiley.com/doi/10.1002/ mana .201100205/full

  12. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  13. Benzofuranoid and bicyclooctanoid neolignans:absolute configuration

    International Nuclear Information System (INIS)

    Alvarenga, M.A. de; Giesbrecht, A.M.; Gottlieb, O.R.; Yoshida, M.

    1977-01-01

    The naturally occuring benzofuranoid and bicyclo (3,2,1) octanoid neolignans have their relative configurations established by 1 H and 13 C NMR, inclusively with aid of the solvent shift technique. Interconversion of the benzofuranoid type compounds, as well as for a benzofuranoid to a bicyclooctanoid derivate, make ORD correlations, ultimately with (2S, 3S) - and (2R,3R)-2,3- dihydrobenzofurans, possible, and led to the absolute configurations of both series of neolignans [pt

  14. Mapping the absolute electromagnetic field strength of individual field components inside a photonic crystal

    NARCIS (Netherlands)

    Denis, T.; Reijnders, B.; Lee, J.H.H.; Vos, Willem L.; Boller, Klaus J.; van der Slot, Petrus J.M.

    2013-01-01

    We present a method to map the absolute electromagnetic field strength inside photonic crystals. We demonstrate our method by applying it to map the electric field component Ez of a two-dimensional photonic crystal slab at microwave frequencies. The slab is placed between two mirrors to create a

  15. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  16. Absolute configuration of verticillane diterpenoids by vibrational circular dichroism.

    Science.gov (United States)

    Cerda-García-Rojas, Carlos M; García-Gutiérrez, Hugo A; Hernandez-Hernandez, Juan D; Roman-Marín, Luisa U; Joseph-Nathan, Pedro

    2007-07-01

    Good agreement between theoretical and experimental vibrational circular dichroism curves of (1S,11S,12S)-(+)-verticilla-3E,7E-dien-12-ol (1) established the absolute configuration of this natural diterpene isolated from Bursera suntui. Molecular modeling of 1 was carried out using the Monte Carlo protocol followed by geometry optimization at the B3LYP 6-31G(d,p) level of theory. The 12-membered ring of 1 was found in a single preferred chair-chair-chair-chair conformation. In the six-membered ring a chair prevails over a distorted boat, and the C-OH bond rotation generates three predominant rotamers. Validation of the minimum energy conformation for 1 was achieved by comparison of theoretical and experimental infrared frequencies, vicinal 1H NMR coupling constants, and X-ray diffraction data. This study confirms that (+)-verticillol 1 isolated from Bursera species has the 1S,11S,12S absolute configuration that corresponds to the same enantiomeric series as verticillanes from Sciadopitys and Taxus, while verticillanes from Jackiella and Jungermannia have antipodal structures.

  17. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  18. Absolutism versus doceañista liberalism. The Visual Counterattack

    Directory of Open Access Journals (Sweden)

    Carlos Reyero

    2017-09-01

    Full Text Available The aim of this article is to identify some dominants themes within absolutists discourses and to sketch out how they are translated to images, in order to persuade against and to denigrate liberalism. Descriptions of public ornaments in events honoring king Ferdinand VII in 1814 and 1823 are used as the main reference sources. Absolutism is recognized looking for associations between images and words, resemblances, metaphors, symbols and iconographic matches. Visual imagery to achieve absolutist goal emphasized the primacy of the king, the rhetoric of vassalage, a strong motherland, the uniqueness of religion, and the exclusion of the political enemy. In order to totally eliminate the constitutional risk, the tradition was presented as a paradise of peace and happiness.

  19. Absolute calibration of Doppler coherence imaging velocity images

    Science.gov (United States)

    Samuell, C. M.; Allen, S. L.; Meyer, W. H.; Howard, J.

    2017-08-01

    A new technique has been developed for absolutely calibrating a Doppler Coherence Imaging Spectroscopy interferometer for measuring plasma ion and neutral velocities. An optical model of the interferometer is used to generate zero-velocity reference images for the plasma spectral line of interest from a calibration source some spectral distance away. Validation of this technique using a tunable diode laser demonstrated an accuracy better than 0.2 km/s over an extrapolation range of 3.5 nm; a two order of magnitude improvement over linear approaches. While a well-characterized and very stable interferometer is required, this technique opens up the possibility of calibrated velocity measurements in difficult viewing geometries and for complex spectral line-shapes.

  20. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Reda, Ibrahim M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dooraghi, Michael R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Grobner, Julian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Thomann, Christian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Long, Chuck [National Oceanic and Atmospheric Administration; McComiskey, Allison [National Oceanic and Atmospheric Administration; Hall, Emiel [National Oceanic and Atmospheric Administration; Wacker, Stefan [Deutscher Wetterdienst

    2018-03-05

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

  1. Absolute Priority for a Vehicle in VANET

    Science.gov (United States)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  2. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  3. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lotze, Stephan, E-mail: lotze@amolf.nl; Versluis, Jan [FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam (Netherlands); Olijve, Luuk L. C.; Schijndel, Luuk van; Milroy, Lech G.; Voets, Ilja K. [Laboratory of Macromolecular and Organic Chemistry, Department of Chemical Engineering and Chemistry, and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Bakker, Huib J., E-mail: bakker@amolf.nl [FOM Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands)

    2015-11-28

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces.

  4. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    Science.gov (United States)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  5. Absolute and Relative Time-Consistent Revealed Preferences

    OpenAIRE

    T. DEMUYNCK

    2007-01-01

    We introduce an Absolute (Relative) Time-consistent Axiom of Revealed Preference which characterizes the consistency of a choice function with the property of absolute (relative) time-consistency and impatience. The axiom requires that the absolute (relative) time-consistent and impatient closure of the revealed preference relation does not conflict with the strict revealed preference relation.

  6. Analysis of absolute flatness testing in sub-stitching interferometer

    Science.gov (United States)

    Jia, Xin; Xu, Fuchao; Xie, Weimin; Xing, Tingwen

    2016-09-01

    Sub-aperture stitching is an effective way to extend the lateral and vertical dynamic range of a conventional interferometer. The test accuracy can be achieved by removing the error of reference surface by the absolute testing method. When the testing accuracy (repeatability and reproducibility) is close to 1nm, in addition to the reference surface, other factors will also affect the measuring accuracy such as environment, zoom magnification, stitching precision, tooling and fixture, the characteristics of optical materials and so on. In the thousand level cleanroom, we establish a good environment system. Long time stability, temperature controlled at 22°+/-0.02°.The humidity and noise are controlled in a certain range. We establish a stitching system in the clean room. The vibration testing system is used to test the vibration. The air pressure testing system is also used. In the motion system, we control the tilt error no more than 4 second to reduce the error. The angle error can be tested by the autocollimator and double grating reading head.

  7. A high-precision mechanical absolute-rotation sensor.

    Science.gov (United States)

    Venkateswara, Krishna; Hagedorn, Charles A; Turner, Matthew D; Arp, Trevor; Gundlach, Jens H

    2014-01-01

    We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad/√Hz above 30 mHz and 0.2 nrad/√Hz above 100 mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 μm above the pivot, giving an excellent horizontal displacement rejection of better than 3 × 10(-5) rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad/√Hz sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced Laser Interferometer Gravitational-wave Observatory.

  8. Absolute ion hydration enthalpies from absolute hardness and some VBT relationships

    Science.gov (United States)

    Kaya, Savaş; Fernandes de Farias, Robson

    2018-01-01

    In the present work, absolute hydration enthalpies are calculated from ion absolute hardness for a series of +1 and -1 ions. The calculated values are compared with those previously reported (Housecroft, 2017) [2] and relationships between Vm-1/3 and absolute hardness are stablished. The following empirical equations have been derived, for cations and anions, respectively: ΔhydHo = -(9.645 η+ + 245.930) and ΔhydHo = -(64.601 η- + 12.321). In such equations, η+ and η- are the absolute hardness. It is shown that for d block monocations (Cu+, Ag+ and Au+), hydration enthalpy is closely related with Clementi effective nuclear charge by the equation: ΔhydHo = -(9.645 η+ + 245.930) (Zeff/(n - 1)), where n is the main quantum number. Furthermore, is shown that a typical VBT parameter (Vm-1/3) is related with η+ and η- values and so, with the energies of the frontier orbitals, that is, is stablished a direct relationship between a structural parameter available by X-ray data and the energy of atomic/molecular orbitals.

  9. How is an absolute democracy possible?

    Directory of Open Access Journals (Sweden)

    Joanna Bednarek

    2011-01-01

    Full Text Available In the last part of the Empire trilogy, Commonwealth, Negri and Hardt ask about the possibility of the self-governance of the multitude. When answering, they argue that absolute democracy, understood as the political articulation of the multitude that does not entail its unification (construction of the people is possible. As Negri states, this way of thinking about political articulation is rooted in the tradition of democratic materialism and constitutes the alternative to the dominant current of modern political philosophy that identifies political power with sovereignty. The multitude organizes itself politically by means of the constitutive power, identical with the ontological creativity or productivity of the multitude. To state the problem of political organization means to state the problem of class composition: political democracy is at the same time economic democracy.

  10. Absolute negative mobility in the anomalous diffusion

    Science.gov (United States)

    Chen, Ruyin; Chen, Chongyang; Nie, Linru

    2017-12-01

    Transport of an inertial Brownian particle driven by the multiplicative Lévy noise was investigated here. Numerical results indicate that: (i) The Lévy noise is able to induce absolute negative mobility (ANM) in the system, while disappearing in the deterministic case; (ii) the ANM can occur in the region of superdiffusion while disappearing in the region of normal diffusion, and the appropriate stable index of the Lévy noise makes the particle move along the opposite direction of the bias force to the maximum degree; (iii) symmetry breaking of the Lévy noise also causes the ANM effect. In addition, the intrinsic physical mechanism and conditions for the ANM to occur are discussed in detail. Our results have the implication that the Lévy noise plays an important role in the occurrence of the ANM phenomenon.

  11. MLU and IPSyn measuring absolute complexity

    Directory of Open Access Journals (Sweden)

    Lea Nieminen

    2009-05-01

    Full Text Available This article compares the results of Mean Length of Utterance (MLU and Index of Productive Syntax (IPSyn with the structural complexity of spontaneous utterances produced by 30-month-old Finnish children in a semi-structured playing situation. The comparison was carried out in order to determine the aspects of structural complexity which can be detected with MLU and IPSyn. This research adopts the frameworks of absolute complexity together with a multidimensional view of utterance structure and, furthermore, applies it through Utterance Analysis (UA. The results of the comparison between the metrics and changes in structural complexity discovered by UA reveal that MLU and IPSyn do function as measures of structural complexity but only if used in close relation to each other. Because they focus on different aspects of utterances, the results of both metrics should be interpreted in relation to one another.DOI: http://dx.doi.org/10.5128/ERYa5.11

  12. A geometrically exact beam element based on the absolute nodal coordinate formulation

    Energy Technology Data Exchange (ETDEWEB)

    Gerstmayr, Johannes [Linz Center of Mechatronics GmbH (Austria)], E-mail: Johannes.gerstmayr@jku.at; Matikainen, Marko K., E-mail: marko.matikainen@lut.fi; Mikkola, Aki M. [Lappeenranta University of Technology, Department of Mechanical Engineering, Institute of Mechatronics and Virtual Engineering (Finland)], E-mail: aki.mikkola@lut.fi

    2008-11-15

    In this study, Reissner's classical nonlinear rod formulation, as implemented by Simo and Vu-Quoc by means of the large rotation vector approach, is implemented into the framework of the absolute nodal coordinate formulation. The implementation is accomplished in the planar case accounting for coupled axial, bending, and shear deformation. By employing the virtual work of elastic forces similarly to Simo and Vu-Quoc in the absolute nodal coordinate formulation, the numerical results of the formulation are identical to those of the large rotation vector formulation. It is noteworthy, however, that the material definition in the absolute nodal coordinate formulation can differ from the material definition used in Reissner's beam formulation. Based on an analytical eigenvalue analysis, it turns out that the high frequencies of cross section deformation modes in the absolute nodal coordinate formulation are only slightly higher than frequencies of common shear modes, which are present in the classical large rotation vector formulation of Simo and Vu-Quoc, as well. Thus, previous claims that the absolute nodal coordinate formulation is inefficient or would lead to ill-conditioned finite element matrices, as compared to classical approaches, could be refuted. In the introduced beam element, locking is prevented by means of reduced integration of certain parts of the elastic forces. Several classical large deformation static and dynamic examples as well as an eigenvalue analysis document the equivalence of classical nonlinear rod theories and the absolute nodal coordinate formulation for the case of appropriate material definitions. The results also agree highly with those computed in commercial finite element codes.

  13. A geometrically exact beam element based on the absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Gerstmayr, Johannes; Matikainen, Marko K.; Mikkola, Aki M.

    2008-01-01

    In this study, Reissner's classical nonlinear rod formulation, as implemented by Simo and Vu-Quoc by means of the large rotation vector approach, is implemented into the framework of the absolute nodal coordinate formulation. The implementation is accomplished in the planar case accounting for coupled axial, bending, and shear deformation. By employing the virtual work of elastic forces similarly to Simo and Vu-Quoc in the absolute nodal coordinate formulation, the numerical results of the formulation are identical to those of the large rotation vector formulation. It is noteworthy, however, that the material definition in the absolute nodal coordinate formulation can differ from the material definition used in Reissner's beam formulation. Based on an analytical eigenvalue analysis, it turns out that the high frequencies of cross section deformation modes in the absolute nodal coordinate formulation are only slightly higher than frequencies of common shear modes, which are present in the classical large rotation vector formulation of Simo and Vu-Quoc, as well. Thus, previous claims that the absolute nodal coordinate formulation is inefficient or would lead to ill-conditioned finite element matrices, as compared to classical approaches, could be refuted. In the introduced beam element, locking is prevented by means of reduced integration of certain parts of the elastic forces. Several classical large deformation static and dynamic examples as well as an eigenvalue analysis document the equivalence of classical nonlinear rod theories and the absolute nodal coordinate formulation for the case of appropriate material definitions. The results also agree highly with those computed in commercial finite element codes

  14. WHY DOES LEIBNIZ NEED ABSOLUTE TIME?

    Directory of Open Access Journals (Sweden)

    NICOLÁS VAUGHAN C.

    2007-08-01

    Full Text Available Resumen: En este ensayo pongo en contraposición dos doctrinas conspicuamenteleibnicianas: la doctrina del tiempo relacional e ideal, y la doctrina de la armonía preestablecida. Argumentaré que si todas las substancias están necesariamentecoordinadas, entonces no tiene sentido negar el carácter absoluto y real del tiempo. En la primera sección describiré la concepción newtoniana y clarkeana del tiempo absoluto; en la segunda discutiré la crítica leibniciana a dicha concepción, crítica sobre la que se erige su doctrina relacional e ideal del tiempo; en la tercera sección daré un vistazo a la metafísica monádica madura de Leibniz, haciendo especial énfasis en la doctrina de la armonía preestablecida; finalmente, en la última sección sugeriré la existencia de una tensión irreconciliable entre estas dos doctrinas.Abstract: In this paper I bring together two characteristically Leibnizean doctrines:the doctrine of relational and ideal time, and the doctrine of preestablished harmony. I will argue that, if every substance is necessarily connected with another, then it makes no sense to deny absolute and real time. In the first section, I will describe Newton’s and Clarke’s conception of absolute time; then, in the second section, I will consider Leibniz’s critique of that conception, on which he bases his ideal and relational doctrine of time. In the third section I will look briefly at Leibniz’s mature monadic metaphysics, taking special account of his doctrine of preestablished harmony. In the last section, I will suggest that there is an irreconcilable tension between these two doctrines.

  15. UNBIASED MOMENT-RATE SPECTRA AND ABSOLUTE SITE EFFECTS IN THE KACHCHH BASIN, INDIA, FROM THE ANALYSIS OF THE AFTERSHOCKS OF THE 2001 Mw 7.6 BHUJ EARTHQUAKE

    Energy Technology Data Exchange (ETDEWEB)

    Malagnini, L; Bodin, P; Mayeda, K; Akinci, A

    2005-05-04

    What can be learned about absolute site effects on ground motions and about earthquake source spectra from recordings at temporary seismic stations, none of which could be considered a 'reference' (hard rock) site, for which no geotechnical information is available, in a very poorly instrumented region? This challenge motivated our current study of aftershocks of the 2001 Mw 7.6 Bhuj earthquake, in Western India. Crustal attenuation and spreading relationships based on the same data used here were determined in an earlier study. In this paper we decouple the ambiguity between absolute source radiation and site effects by first computing robust estimates of moment-rate spectra of about 200 aftershocks in each of two depth ranges. Using these new estimates of sourcespectra, and our understanding of regional wave propagation, we extract the absolute site terms of the sites of the temporary deployment. Absolute site terms (one for each component of the ground motion, for each station) are computed in an average sense, via an L{sub 1}-norm minimization, and results for each site are averaged over wide ranges of azimuths and takeoff angles. The Bhuj deployment is characterized by a variable shallow geology, mostly of soft sedimentary units. Vertical site terms in the region were observed to be almost featureless and slightly < 1.0 within wide frequency ranges. As a result, H/V spectral ratios mimic the absolute behaviors of absolute horizontal site terms, and they generally overpredict them. On the contrary, with respect to the results for sedimentary rock sites (limestone, dolomite) obtained by Malagnini et al. (2004), H/V spectral ratios in their study did not have much in common with absolute horizontal site terms. Spectral ratios between the vector sum of the computed horizontal site terms for the temporary deployment with respect to the same quantity computed at the hardest rock station available, BAC1, are seriously biased by its non-flat, non

  16. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  17. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Santos, Emilie M.M.; Yoo, Albert J.; Beenen, Ludo F.; Majoie, Charles B.; Berkhemer, Olvert A.; Blanken, Mark D. den; Wismans, Carrie; Niessen, Wiro J.; Marquering, Henk A.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  18. An absolute nuclear magnetic resonance magnetometer

    International Nuclear Information System (INIS)

    Salvi, A.

    1961-10-01

    After an introduction in which the various work undertaken since the discovery of nuclear magnetic resonance is rapidly reviewed, the author describes briefly In the first chapter three types of NMR magnetometers, giving the advantages and disadvantages of each of them and deducing from this the design of the apparatus having the greatest number of qualities Chapter II is devoted to the crossed coil nuclear oscillator which operates continuously over a wide range (800 gamma). To avoid an error due to a carrying over the frequency, the measurement is carried out using bands of 1000 γ. Chapter III deals with frequency measurements. The author describes an original arrangement which makes possible the frequency-field conversion with an accuracy of ± 5 x 10 -6 , and the differential measurement between two nuclear oscillators. The report finishes with a conclusion and a few recordings. (author) [fr

  19. Linking the microwave and optical frequency domains with a phase-coherent bridge

    International Nuclear Information System (INIS)

    Luiten, A.

    2000-01-01

    Full text: It has been a long-standing dream of physicists and engineers to be able to examine (and manipulate) optical frequency signals in the same ways that are possible with radio-frequency and microwave signals. A great deal of effort has been invested at a number of national research facilities to develop a technology which can measure the frequency of just one optical frequency signal. In contrast to the complexity of these systems of the past, we now stand at the threshold of a new period in which it will become commonplace to measure the frequency of signals throughout the visible and infrared parts of the spectrum. It will even be possible to measure the absolute phase of an optical signal at an instant in time. This development will allow the construction of a relatively simple 'clock-work' that can convert the output of a future generation of optical clocks into useful electronic signals. The fundamental concept of this new generation of frequency chains is the exact measurement of large optical frequency intervals in terms of a microwave or radio-frequency reference signal. This can now be achieved in a single step by using the output of a mode-locked femtosecond laser as a 'frequency ruler' in the optical domain: the periodic sequence of pulses at the output of this laser can be viewed equivalently as an equally spaced comb of frequency markers in frequency space. Comparison of this frequency ruler' with the frequency interval can immediately yield the width of the interval. Using well-known nonlinear optical techniques it is possible to relate the measured frequency interval to the absolute frequency of some desired optical signal. In this talk I will discuss the particular design that we are using at University of Western Australia together with the remarkable recent results of the groups at Max-Planck Institut fur Quantenoptik-Garching and NlST-Boulder. In the near future we expect to be able to synthesize high quality optical radiation (linewidth

  20. Audio-visual interactions uniquely contribute to resolution of visual conflict in people possessing absolute pitch.

    Directory of Open Access Journals (Sweden)

    Sujin Kim

    Full Text Available Individuals possessing absolute pitch (AP are able to identify a given musical tone or to reproduce it without reference to another tone. The present study sought to learn whether this exceptional auditory ability impacts visual perception under stimulus conditions that provoke visual competition in the form of binocular rivalry. Nineteen adult participants with 3-19 years of musical training were divided into two groups according to their performance on a task involving identification of the specific note associated with hearing a given musical pitch. During test trials lasting just over half a minute, participants dichoptically viewed a scrolling musical score presented to one eye and a drifting sinusoidal grating presented to the other eye; throughout the trial they pressed buttons to track the alternations in visual awareness produced by these dissimilar monocular stimuli. On "pitch-congruent" trials, participants heard an auditory melody that was congruent in pitch with the visual score, on "pitch-incongruent" trials they heard a transposed auditory melody that was congruent with the score in melody but not in pitch, and on "melody-incongruent" trials they heard an auditory melody completely different from the visual score. For both groups, the visual musical scores predominated over the gratings when the auditory melody was congruent compared to when it was incongruent. Moreover, the AP participants experienced greater predominance of the visual score when it was accompanied by the pitch-congruent melody compared to the same melody transposed in pitch; for non-AP musicians, pitch-congruent and pitch-incongruent trials yielded equivalent predominance. Analysis of individual durations of dominance revealed differential effects on dominance and suppression durations for AP and non-AP participants. These results reveal that AP is accompanied by a robust form of bisensory interaction between tonal frequencies and musical notation that boosts

  1. What is Needed for Absolute Paleointensity?

    Science.gov (United States)

    Valet, J. P.

    2015-12-01

    Many alternative approaches to the Thellier and Thellier technique for absolute paleointensity have been proposed during the past twenty years. One reason is the time consuming aspect of the experiments. Another reason is to avoid uncertainties in determinations of the paleofield which are mostly linked to the presence of multidomain grains. Despite great care taken by these new techniques, there is no indication that they always provide the right answer and in fact sometimes fail. We are convinced that the most valid approach remains the original double heating Thellier protocol provided that natural remanence is controlled by pure magnetite with a narrow distribution of small grain sizes, mostly single domains. The presence of titanium, even in small amount generates biases which yield incorrect field values. Single domain grains frequently dominate the magnetization of glass samples, which explains the success of this selective approach. They are also present in volcanic lava flows but much less frequently, and therefore contribute to the low success rate of most experiments. However the loss of at least 70% of the magnetization at very high temperatures prior to the Curie point appears to be an essential prerequisite that increases the success rate to almost 100% and has been validated from historical flows and from recent studies. This requirement can easily be tested by thermal demagnetization while low temperature experiments can document the detection of single domain magnetite using the δFC/δZFC parameter as suggested (Moskowitz et al, 1993) for biogenic magnetite.

  2. Comparison of absolute neutrophil to CD4 lymphocyte values as a ...

    African Journals Online (AJOL)

    1.5 x 109/L is therefore obviously not appropriate for people of negroid descent whose lower reference limit is ANC 1.3 x 109/L.6,7 Neutropenia remains the most common predisposing factor to infections in cancer pa- tients.1,8,9 The accepted definition of neutropenia is an absolute neutrophil count ≤ 1.5 x 109/L,8 though ...

  3. Dynamic Analysis of Offshore Oil Pipe Installation Using the Absolute Nodal Coordinate Formulation

    DEFF Research Database (Denmark)

    Nielsen, Jimmy D; Madsen, Søren B; Hyldahl, Per Christian

    2013-01-01

    The Absolute Nodal Coordinate Formulation (ANCF) has shown promising results in dynamic analysis of structures that undergo large deformation. The method relaxes the assumption of infinitesimal rotations. Being based in a fixed inertial reference frame leads to a constant mass matrix and zero......, are included to mimic the external forces acting on the pipe during installation. The scope of this investigation is to demonstrate the ability using the ANCF to analyze the dynamic behavior of an offshore oil pipe during installation...

  4. Absolute Calibration of Si iRMs used for Measurements of Si Paleo-nutrient proxies

    Science.gov (United States)

    Vocke, R. D., Jr.; Rabb, S. A.

    2016-12-01

    Silicon isotope variations (reported as δ30Si and δ29Si, relative to NBS28) in silicic acid dissolved in ocean waters, in biogenic silica and in diatoms are extremely informative paleo-nutrient proxies. The resolution and comparability of such measurements depend on the quality of the isotopic Reference Materials (iRMs) defining the delta scale. We report new absolute Si isotopic measurements on the iRMs NBS28 (RM 8546 - Silica Sand), Diatomite, and Big Batch using the Avogadro measurement approach and comparing them with prior assessments of these iRMs. The Avogadro Si measurement technique was developed by the German Physikalish-Technische Bundesanstalt (PTB) to provide a precise and highly accurate method to measure absolute isotopic ratios in highly enriched 28Si (99.996%) material. These measurements are part of an international effort to redefine the kg and mole based on the Planck constant h and the Avogadro constant NA, respectively (Vocke et al., 2014 Metrologia 51, 361, Azuma et al., 2015 Metrologia 52 360). This approach produces absolute Si isotope ratio data with lower levels of uncertainty when compared to the traditional "Atomic Weights" method of absolute isotope ratio measurement calibration. This is illustrated in Fig. 1 where absolute Si isotopic measurements on SRM 990, separated by 40+ years of advances in instrumentation, are compared. The availability of this new technique does not say that absolute Si isotopic ratios are or ever will be better for normal Si isotopic measurements when seeking isotopic variations in nature, because they are not. However, by determining the absolute isotopic ratios of all the Si iRM scale artifacts, such iRMs become traceable to the metric system (SI); thereby automatically conferring on all the artifact-based δ30Si and δ29Si measurements traceability to the base SI unit, the mole. Such traceability should help reduce the potential of bias between different iRMs and facilitate the replacement of delta

  5. Photonic microwave signals with zeptosecond-level absolute timing noise

    Science.gov (United States)

    Xie, Xiaopeng; Bouchand, Romain; Nicolodi, Daniele; Giunta, Michele; Hänsel, Wolfgang; Lezius, Matthias; Joshi, Abhay; Datta, Shubhashish; Alexandre, Christophe; Lours, Michel; Tremblin, Pierre-Alain; Santarelli, Giorgio; Holzwarth, Ronald; Le Coq, Yann

    2017-01-01

    Photonic synthesis of radiofrequency (RF) waveforms revived the quest for unrivalled microwave purity because of its ability to convey the benefits of optics to the microwave world. In this work, we perform a high-fidelity transfer of frequency stability between an optical reference and a microwave signal via a low-noise fibre-based frequency comb and cutting-edge photodetection techniques. We demonstrate the generation of the purest microwave signal with a fractional frequency stability below 6.5 × 10-16 at 1 s and a timing noise floor below 41 zs Hz-1/2 (phase noise below -173 dBc Hz-1 for a 12 GHz carrier). This outperforms existing sources and promises a new era for state-of-the-art microwave generation. The characterization is achieved through a heterodyne cross-correlation scheme with the lowermost detection noise. This unprecedented level of purity can impact domains such as radar systems, telecommunications and time-frequency metrology. The measurement methods developed here can benefit the characterization of a broad range of signals.

  6. Marx on absolute and relative wages

    OpenAIRE

    Levrero, Enrico Sergio

    2009-01-01

    The aim of this paper is to clarify some aspects of Marx's analysis of the determinants of wages and of the peculiarities of labour as a commodity, concentrating upon three related issues. The first is that of Marx's notion of the subsistence (or natural) wage rate: subsistence wage will be shown to stem, according to Marx, from socially determined conditions of reproduction of an efficient labouring class. The second issue refers to the distinction between the natural and the market wage rat...

  7. A Fiducial Reference Stie for Satellite Altimetry in Crete, Greece

    Science.gov (United States)

    Mertikas, Stelios; Donlon, Craig; Mavrocordatos, Constantin; Bojkov, Bojan; Femenias, Pierre; Parrinello, Tommaso; Picot, Nicolas; Desjonqueres, Jean-Damien; Andersen, Ole Baltazar

    2016-08-01

    With the advent of diverse satellite altimeters and variant measuring techniques, it has become mature in the scientific community, that an absolute reference Cal/Val site is regularly maintained to define, monitor, control the responses of any altimetric system.This work sets the ground for the establishment of a Fiducial Reference Site for ESA satellite altimetry in Gavdos and West Crete, Greece. It will consistently and reliably determine (a) absolute altimeter biases and their drifts; (b) relative bias among diverse missions; but also (c) continuously and independently connect different missions, on a common and reliable reference and also to SI-traceable measurements. Results from this fiducial reference site will be based on historic Cal/Val site measurement records, and will be the yardstick for building up capacity for monitoring climate change. This will be achieved by defining and assessing any satellite altimeter measurements to known, controlled and absolute reference signals with different techniques, processes and instrumentation.

  8. Robust laser frequency stabilization by serrodyne modulation.

    Science.gov (United States)

    Kohlhaas, Ralf; Vanderbruggen, Thomas; Bernon, Simon; Bertoldi, Andrea; Landragin, Arnaud; Bouyer, Philippe

    2012-03-15

    We report the relative frequency stabilization of a distributed feedback erbium-doped fiber laser on an optical cavity by serrodyne frequency shifting. A correction bandwidth of 2.3 MHz and a dynamic range of 220 MHz are achieved, which leads to a strong robustness against large disturbances up to high frequencies. We demonstrate that serrodyne frequency shifting reaches a higher correction bandwidth and lower relative frequency noise level compared to a standard acousto-optical modulator based scheme. Our results allow us to consider promising applications in the absolute frequency stabilization of lasers on optical cavities.

  9. Evaluation of the absolute regional temperature potential

    Directory of Open Access Journals (Sweden)

    D. T. Shindell

    2012-09-01

    Full Text Available The Absolute Regional Temperature Potential (ARTP is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90–28° S, 28° S–28° N, 28–60° N and 60–90° N as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within ±20% of the actual responses, though there are some exceptions for 90–28° S and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the ±20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39–45% and 9–39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  10. Absolute Radiometric Calibration of KOMPSAT-3A

    Directory of Open Access Journals (Sweden)

    H. Y. Ahn

    2016-06-01

    Full Text Available This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A performed by the Korea Aerospace Research Institute (KARI and the Pukyong National University Remote Sensing Group (PKNU RSG in 2015.The primary stages of this study are summarized as follows: (1 A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2 To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4. Correlations between top-of-atmosphere (TOA radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  11. Absolute parameters of young stars: QZ Carinae

    Science.gov (United States)

    Walker, W. S. G.; Blackford, M.; Butland, R.; Budding, E.

    2017-09-01

    New high-resolution spectroscopy and BVR photometry together with literature data on the complex massive quaternary star QZ Car are collected and analysed. Absolute parameters are found as follows. System A: M1 = 43 (±3), M2 = 19 (+3 -7), R1 = 28 (±2), R2 = 6 (±2), (⊙); T1 ˜ 28 000, T2 ˜ 33 000 K; System B: M1 = 30 (±3), M2 = 20 (±3), R1 = 10 (±0.5), R2 = 20 (±1), (⊙); T1 ˜ 36 000, T2 ˜ 30 000 K (model dependent temperatures). The wide system AB: Period = 49.5 (±1) yr, Epochs, conjunction = 1984.8 (±1), periastron = 2005.3 (±3) yr, mean separation = 65 (±3), (au); orbital inclination = 85 (+5 -15) deg, photometric distance ˜2700 (±300) pc, age = 4 (±1) Myr. Other new contributions concern: (a) analysis of the timing of minima differences (O - C)s for the eclipsing binary (System B); (b) the width of the eclipses, pointing to relatively large effects of radiation pressure; (c) inferences from the rotational widths of lines for both Systems A and B; and (d) implications for theoretical models of early-type stars. While feeling greater confidence on the quaternary's general parametrization, observational complications arising from strong wind interactions or other, unclear, causes still inhibit precision and call for continued multiwavelength observations. Our high-inclination value for the AB system helps to explain failures to resolve the wide binary in the previous years. The derived young age independently confirms membership of QZ Car to the open cluster Collinder 228.

  12. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Planck absolute entropy of a rotating BTZ black hole

    Science.gov (United States)

    Riaz, S. M. Jawwad

    2018-04-01

    In this paper, the Planck absolute entropy and the Bekenstein-Smarr formula of the rotating Banados-Teitelboim-Zanelli (BTZ) black hole are presented via a complex thermodynamical system contributed by its inner and outer horizons. The redefined entropy approaches zero as the temperature of the rotating BTZ black hole tends to absolute zero, satisfying the Nernst formulation of a black hole. Hence, it can be regarded as the Planck absolute entropy of the rotating BTZ black hole.

  14. Do individuals with Williams syndrome possess absolute pitch?

    Science.gov (United States)

    Martínez-Castilla, Pastora; Sotillo, María; Campos, Ruth

    2013-01-01

    Although absolute pitch (AP) is a rare skill in typical development, individuals with Williams syndrome (WS) are often referred to as possessing this musical ability. However, there is paucity of research on the topic. In this article, 2 studies were conducted to evaluate AP in WS. In Study 1, seven musically trained individuals with WS, 14 musically trained typically developing controls matched for chronological age, and 2 experienced musicians with AP completed a pitch-identification task. Although the task was a classical assessment of AP, it required participants to have musical knowledge, and the availability and accessibility of musically trained individuals with WS is very low. In Study 2, a paradigm suitable for evaluating AP in individuals without musical training was used, which made it possible to evaluate a larger group of participants with WS. A pitch memory test for isolated tones was presented to 27 individuals with WS, 54 typically developing peers matched for chronological age, and the 2 musicians with AP. Both individuals with WS and their controls obtained low results in the two studies. They showed an arbitrary pattern of response, and their performance was far from that of musicians with AP. Therefore, participants with WS did not appear to possess AP. Unlike what is usually claimed, results suggest that AP is not a remarkable ability in WS and that, as in the typically developing population, this musical ability is also rare in individuals with WS.

  15. A nonmusical paradigm for identifying absolute pitch possessors

    Science.gov (United States)

    Ross, David A.; Olson, Ingrid R.; Marks, Lawrence E.; Gore, John C.

    2004-09-01

    The ability to identify and reproduce sounds of specific frequencies is remarkable and uncommon. The etiology and defining characteristics of this skill, absolute pitch (AP), have been very controversial. One theory suggests that AP requires a specific type of early musical training and that the ability to encode and remember tones depends on these learned musical associations. An alternate theory argues that AP may be strongly dependent on hereditary factors and relatively independent of musical experience. To date, it has been difficult to test these hypotheses because all previous paradigms for identifying AP have required subjects to employ knowledge of musical nomenclature. As such, these tests are insensitive to the possibility of discovering AP in either nonmusicians or musicians of non-Western training. Based on previous literature in pitch memory, a paradigm is presented that is intended to distinguish between AP possessors and nonpossessors independent of the subjects' musical experience. The efficacy of this method is then tested with 20 classically defined AP possessors and 22 nonpossessors. Data from these groups strongly support the validity of the paradigm. The use of a nonmusical paradigm to identify AP may facilitate research into many aspects of this phenomenon.

  16. Genomic DNA-based absolute quantification of gene expression in Vitis.

    Science.gov (United States)

    Gambetta, Gregory A; McElrone, Andrew J; Matthews, Mark A

    2013-07-01

    Many studies in which gene expression is quantified by polymerase chain reaction represent the expression of a gene of interest (GOI) relative to that of a reference gene (RG). Relative expression is founded on the assumptions that RG expression is stable across samples, treatments, organs, etc., and that reaction efficiencies of the GOI and RG are equal; assumptions which are often faulty. The true variability in RG expression and actual reaction efficiencies are seldom determined experimentally. Here we present a rapid and robust method for absolute quantification of expression in Vitis where varying concentrations of genomic DNA were used to construct GOI standard curves. This methodology was utilized to absolutely quantify and determine the variability of the previously validated RG ubiquitin (VvUbi) across three test studies in three different tissues (roots, leaves and berries). In addition, in each study a GOI was absolutely quantified. Data sets resulting from relative and absolute methods of quantification were compared and the differences were striking. VvUbi expression was significantly different in magnitude between test studies and variable among individual samples. Absolute quantification consistently reduced the coefficients of variation of the GOIs by more than half, often resulting in differences in statistical significance and in some cases even changing the fundamental nature of the result. Utilizing genomic DNA-based absolute quantification is fast and efficient. Through eliminating error introduced by assuming RG stability and equal reaction efficiencies between the RG and GOI this methodology produces less variation, increased accuracy and greater statistical power. © 2012 Scandinavian Plant Physiology Society.

  17. Absolute IGS antenna phase center model igs08.atx: status and potential improvements

    Science.gov (United States)

    Schmid, R.; Dach, R.; Collilieux, X.; Jäggi, A.; Schmitz, M.; Dilssner, F.

    2016-04-01

    On 17 April 2011, all analysis centers (ACs) of the International GNSS Service (IGS) adopted the reference frame realization IGS08 and the corresponding absolute antenna phase center model igs08.atx for their routine analyses. The latter consists of an updated set of receiver and satellite antenna phase center offsets and variations (PCOs and PCVs). An update of the model was necessary due to the difference of about 1 ppb in the terrestrial scale between two consecutive realizations of the International Terrestrial Reference Frame (ITRF2008 vs. ITRF2005), as that parameter is highly correlated with the GNSS satellite antenna PCO components in the radial direction.

  18. Accurate absolute measurement of trapped Cs atoms in a MOT

    International Nuclear Information System (INIS)

    Talavera O, M.; Lopez R, M.; Carlos L, E. de; Jimenez S, S.

    2007-01-01

    A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrologia, CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (σ + - σ - ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is l MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to 6 x 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%. (Author)

  19. Precision spectroscopy with a frequency-comb-calibrated solar spectrograph

    Science.gov (United States)

    Doerr, H.-P.

    2015-06-01

    The measurement of the velocity field of the plasma at the solar surface is a standard diagnostic tool in observational solar physics. Detailed information about the energy transport as well as on the stratification of temperature, pressure and magnetic fields in the solar atmosphere are encoded in Doppler shifts and in the precise shape of the spectral lines. The available instruments deliver data of excellent quality and precision. However, absolute wavelength calibration in solar spectroscopy was so far mostly limited to indirect methods and in general suffers from large systematic uncertainties of the order of 100 m/s. During the course of this thesis, a novel wavelength calibration system based on a laser frequency comb was deployed to the solar Vacuum Tower Telescope (VTT), Tenerife, with the goal of enabling highly accurate solar wavelength measurements at the level of 1 m/s on an absolute scale. The frequency comb was developed in a collaboration between the Kiepenheuer-Institute for Solar Physics, Freiburg, Germany and the Max Planck Institute for Quantum Optics, Garching, Germany. The efforts cumulated in the new prototype instrument LARS (Lars is an Absolute Reference Spectrograph) for solar precision spectroscopy which is in preliminary scientific operation since~2013. The instrument is based on the high-resolution echelle spectrograph of the VTT for which feed optics based on single-mode optical fibres were developed for this project. The setup routinely achieves an absolute calibration accuracy of 60 cm/s and a repeatability of 2.5 cm/s. An unprecedented repeatability of only 0.32 cm/s could be demonstrated with a differential calibration scheme. In combination with the high spectral resolving power of the spectrograph of 7x10^5 and virtually absent internal scattered light, LARS provides a spectral purity and fidelity that previously was the domain of Fourier-transform spectrometers only. The instrument therefore provides unique capabilities for

  20. An Absolute Valve for the ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Jones, Ch.; Chuilon, B.; Michael, W.

    2006-01-01

    In the ITER reference design a fast shutter was included to limit tritium migration into the beamline vacuum enclosures. The need was recently identified to extend the functionality of the fast shutter to that of an absolute valve in order to facilitate injector maintenance procedures and to satisfy safety requirements in case of an in-vessel loss of coolant event. Three concepts have been examined satisfying the ITER requirements for speed of actuation, sealing performance over the required lifetime, and pressure differential in fault scenarios, namely: a rectangular closure section; a circular cross section; and a rotary JET-type valve. The rectangular section represents the most efficient usage of the available space envelope and leads to a minimum-mass system, although it requires greater total force for a given load per unit length of seal. However, a metallic seal of the '' hard/hard '' type, where the seal relies on the elastic properties of the material and does not utilise any type of spring device, can provide the required seal performance with typical loading of 200 kg/cm. The conceptual design of the proposed absolute valve will be presented. The aperture dimensions are 1.45 m high by 0.6 m wide, with minimum achievable leak rate of 1 · 10 -9 mbarl/s and maximum pressure differential of 3 bar across the valve. Sealing force is provided using two seal plates, linked by a 3 mm thick ' omega ' diaphragm, by pressurisation of the interspace to 8 bar; this allows for a relative movement of the plates of 2 mm. Movement of the device perpendicular to the beam direction is carried out using a novel magnetic drive in order to transmit the motive force across the vacuum boundary, similar to that demonstrated on a test-rig in an earlier study. The conceptual design includes provision of all the services such as pneumatics and water cooling to cope with the heat loads from neutral beams in quasi steady-state operation and from the ITER plasma. A future programme

  1. Absolute density measurements in the middle atmosphere

    Directory of Open Access Journals (Sweden)

    M. Rapp

    2001-05-01

    Full Text Available In the last ten years a total of 25 sounding rockets employing ionization gauges have been launched at high latitudes ( ~ 70° N to measure total atmospheric density and its small scale fluctuations in an altitude range between 70 and 110 km. While the determination of small scale fluctuations is unambiguous, the total density analysis has been complicated in the past by aerodynamical disturbances leading to densities inside the sensor which are enhanced compared to atmospheric values. Here, we present the results of both Monte Carlo simulations and wind tunnel measurements to quantify this aerodynamical effect. The comparison of the resulting ‘ram-factor’ profiles with empirically determined density ratios of ionization gauge measurements and falling sphere measurements provides excellent agreement. This demonstrates both the need, but also the possibility, to correct aerodynamical influences on measurements from sounding rockets. We have determined a total of 20 density profiles of the mesosphere-lower-thermosphere (MLT region. Grouping these profiles according to season, a listing of mean density profiles is included in the paper. A comparison with density profiles taken from the reference atmospheres CIRA86 and MSIS90 results in differences of up to 40%. This reflects that current reference atmospheres are a significant potential error source for the determination of mixing ratios of, for example, trace gas constituents in the MLT region.Key words. Middle atmosphere (composition and chemistry; pressure, density, and temperature; instruments and techniques

  2. Absolute density measurements in the middle atmosphere

    Directory of Open Access Journals (Sweden)

    M. Rapp

    Full Text Available In the last ten years a total of 25 sounding rockets employing ionization gauges have been launched at high latitudes ( ~ 70° N to measure total atmospheric density and its small scale fluctuations in an altitude range between 70 and 110 km. While the determination of small scale fluctuations is unambiguous, the total density analysis has been complicated in the past by aerodynamical disturbances leading to densities inside the sensor which are enhanced compared to atmospheric values. Here, we present the results of both Monte Carlo simulations and wind tunnel measurements to quantify this aerodynamical effect. The comparison of the resulting ‘ram-factor’ profiles with empirically determined density ratios of ionization gauge measurements and falling sphere measurements provides excellent agreement. This demonstrates both the need, but also the possibility, to correct aerodynamical influences on measurements from sounding rockets. We have determined a total of 20 density profiles of the mesosphere-lower-thermosphere (MLT region. Grouping these profiles according to season, a listing of mean density profiles is included in the paper. A comparison with density profiles taken from the reference atmospheres CIRA86 and MSIS90 results in differences of up to 40%. This reflects that current reference atmospheres are a significant potential error source for the determination of mixing ratios of, for example, trace gas constituents in the MLT region.

    Key words. Middle atmosphere (composition and chemistry; pressure, density, and temperature; instruments and techniques

  3. A study on photonic crystal slab waveguide with absolute photonic band gap

    Directory of Open Access Journals (Sweden)

    Katsumasa Satoh

    2018-02-01

    Full Text Available Most of the conventional photonic crystal (PhC slab waveguides have a photonic bandgap (PBG only for one polarization state of two orthogonal polarization states. In this paper, westudy on an absolute PBG that can realize PBG for both polarizations in the same frequency range anddemonstrate that an absolute PBG can be realized in PhC structures proposed here. In the numericalanalysis and design of PhC structures, we employ the two-dimensional finite element method (FEMbased on the effective index method (EIM. First, we propose two-types of PhC structures with anabsolute PBG and show that a steering type PhC is superior to an air-ring type PhC to obtain a widebandabsolute PBG. It is also shown that the optimized steering type PhC has the absolute PBG whosebandwidth of 164 nm at the center wavelength of 1.55 μm. Furthermore, we design PhC waveguidesbased on the obtained PhC structure having an absolute PBG in order to obtain guided modes for bothpolarization states within the same wavelength range. The transmission properties of the designed PhCwaveguides are also investigated and 60 degree bends which are required in compact photonic circuitsare designed. From these results, the possibility to realize compact polarization multiplexing photonicdevices is shown.

  4. Robust power system frequency control

    CERN Document Server

    Bevrani, Hassan

    2014-01-01

    This updated edition of the industry standard reference on power system frequency control provides practical, systematic and flexible algorithms for regulating load frequency, offering new solutions to the technical challenges introduced by the escalating role of distributed generation and renewable energy sources in smart electric grids. The author emphasizes the physical constraints and practical engineering issues related to frequency in a deregulated environment, while fostering a conceptual understanding of frequency regulation and robust control techniques. The resulting control strategi

  5. Does Absolute Synonymy exist in Owere-Igbo? | Omego | AFRREV ...

    African Journals Online (AJOL)

    Among Igbo linguistic researchers, determining whether absolute synonymy exists in Owere–Igbo, a dialect of the Igbo language predominantly spoken by the people of Owerri, Imo State, Nigeria, has become a thorny issue. While some linguistic scholars strive to establish that absolute synonymy exists in the lexical ...

  6. Determination of Absolute Zero Using a Computer-Based Laboratory

    Science.gov (United States)

    Amrani, D.

    2007-01-01

    We present a simple computer-based laboratory experiment for evaluating absolute zero in degrees Celsius, which can be performed in college and undergraduate physical sciences laboratory courses. With a computer, absolute zero apparatus can help demonstrators or students to observe the relationship between temperature and pressure and use…

  7. Nonlinear optical response of a gold surface in the visible range: A study by two-color sum-frequency generation spectroscopy. I. Experimental determination.

    Science.gov (United States)

    Dalstein, L; Revel, A; Humbert, C; Busson, B

    2018-04-07

    We experimentally determine the effective nonlinear second-order susceptibility of gold over the visible spectral range. To reach that goal, we probe by vibrational two-color sum-frequency generation spectroscopy the methyl stretching region of a dodecanethiol self-assembled monolayer adsorbed on a gold film. The sum-frequency generation spectra show a remarkable shape reversal when the visible probe wavelength is tuned from 435 to 705 nm. After correcting from Fresnel effects, the methyl stretching vibrations serve as an internal reference, allowing to extract the dispersion of the absolute phase and relative amplitude of the effective nonlinear optical response of gold in the visible range.

  8. Implications of an absolute simultaneity theory for cosmology and universe acceleration.

    Directory of Open Access Journals (Sweden)

    Edward T Kipreos

    Full Text Available An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT, has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift-distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe.

  9. Implications of an absolute simultaneity theory for cosmology and universe acceleration.

    Science.gov (United States)

    Kipreos, Edward T

    2014-01-01

    An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift-distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe.

  10. Implications of an Absolute Simultaneity Theory for Cosmology and Universe Acceleration

    Science.gov (United States)

    Kipreos, Edward T.

    2014-01-01

    An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift–distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe. PMID:25536116

  11. Absolute testing of flats in sub-stitching interferometer by rotation-shift method

    Science.gov (United States)

    Jia, Xin; Xu, Fuchao; Xie, Weimin; Li, Yun; Xing, Tingwen

    2015-09-01

    Most of the commercial available sub-aperture stitching interferometers measure the surface with a standard lens that produces a reference wavefront, and the precision of the interferometer is generally limited by the standard lens. The test accuracy can be achieved by removing the error of reference surface by the absolute testing method. When the testing accuracy (repeatability and reproducibility) is close to 1nm, in addition to the reference surface, other factors will also affect the measuring accuracy such as environment, zoom magnification, stitching precision, tooling and fixture, the characteristics of optical materials and so on. We establish a stitching system in the thousand level cleanroom. The stitching system is including the Zygo interferometer, the motion system with Bilz active isolation system at level VC-F. We review the traditional absolute flat testing methods and emphasize the method of rotation-shift functions. According to the rotation-shift method we get the profile of the reference lens and the testing lens. The problem of the rotation-shift method is the tilt error. In the motion system, we control the tilt error no more than 4 second to reduce the error. In order to obtain higher testing accuracy, we analyze the influence surface shape measurement accuracy by recording the environment error with the fluke testing equipment.

  12. Tracking frequency laser distance gauge

    International Nuclear Information System (INIS)

    Phillips, J.D.; Reasenberg, R.D.

    2005-01-01

    Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require laser distance gauges of substantially improved performance. We describe a laser gauge, based on Pound-Drever-Hall locking, in which the optical frequency is adjusted to maintain an interferometer's null condition. This technique has been demonstrated with pm performance. Automatic fringe hopping allows it to track arbitrary distance changes. The instrument is intrinsically free of the nm-scale cyclic bias present in traditional (heterodyne) high-precision laser gauges. The output is a radio frequency, readily measured to sufficient accuracy. The laser gauge has operated in a resonant cavity, which improves precision, can suppress the effects of misalignments, and makes possible precise automatic alignment. The measurement of absolute distance requires little or no additional hardware, and has also been demonstrated. The proof-of-concept version, based on a stabilized HeNe laser and operating on a 0.5 m path, has achieved 10 pm precision with 0.1 s integration time, and 0.1 mm absolute distance accuracy. This version has also followed substantial distance changes as fast as 16 mm/s. We show that, if the precision in optical frequency is a fixed fraction of the linewidth, both incremental and absolute distance precision are independent of the distance measured. We discuss systematic error sources, and present plans for a new version of the gauge based on semiconductor lasers and fiber-coupled components

  13. Mini-implants and miniplates generate sub-absolute and absolute anchorage.

    Science.gov (United States)

    Consolaro, Alberto

    2014-01-01

    The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces. Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

  14. Mini-implants and miniplates generate sub-absolute and absolute anchorage

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-06-01

    Full Text Available The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces.Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

  15. Measuring Absolute RNA Copy Numbers at High Temporal Resolution Reveals Transcriptome Kinetics in Development

    Directory of Open Access Journals (Sweden)

    Nick D.L. Owens

    2016-01-01

    Full Text Available Transcript regulation is essential for cell function, and misregulation can lead to disease. Despite technologies to survey the transcriptome, we lack a comprehensive understanding of transcript kinetics, which limits quantitative biology. This is an acute challenge in embryonic development, where rapid changes in gene expression dictate cell fate decisions. By ultra-high-frequency sampling of Xenopus embryos and absolute normalization of sequence reads, we present smooth gene expression trajectories in absolute transcript numbers. During a developmental period approximating the first 8 weeks of human gestation, transcript kinetics vary by eight orders of magnitude. Ordering genes by expression dynamics, we find that “temporal synexpression” predicts common gene function. Remarkably, a single parameter, the characteristic timescale, can classify transcript kinetics globally and distinguish genes regulating development from those involved in cellular metabolism. Overall, our analysis provides unprecedented insight into the reorganization of maternal and embryonic transcripts and redefines our ability to perform quantitative biology.

  16. Intraplate Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K. G.; Camelbeeck, T.

    2007-12-01

    We have conducted repeated absolute gravity (AG) measurements across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken since 2000 and repeated twice a year. Our analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36.7 nm s-2/year equivalent to 18.4 mm/yr is due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nms-2 to 43±29 nms-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. In Ostend, the AG time series agrees with tide gauge data, global mean sea level and altimeter measurements but disagrees with the CGPS. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes in an intraplate context.

  17. Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K.; Camelbeeck, T.

    2009-05-01

    Repeated absolute gravity (AG) measurements have been performed across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken in 2000 and repeated twice a year. Analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36 nm -2/year, equivalent to 18 mm/yr, is at least in parts due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nm s-2 to 43±29 nm s-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes.

  18. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  19. A linewidth-narrowed and frequency-stabilized dye laser for application in laser cooling of molecules.

    Science.gov (United States)

    Dai, D P; Xia, Y; Yin, Y N; Yang, X X; Fang, Y F; Li, X J; Yin, J P

    2014-11-17

    We demonstrate a robust and versatile solution for locking the continuous-wave dye laser for applications in laser cooling of molecules which need linewidth-narrowed and frequency-stabilized lasers. The dye laser is first stabilized with respect to a reference cavity by Pound-Drever-Hall (PDH) technique which results in a single frequency with the linewidth 200 kHz and short-term stabilization, by stabilizing the length of the reference cavity to a stabilized helium-neon laser we simultaneously transfer the ± 2 MHz absolute frequency stability of the helium-neon laser to the dye laser with long-term stabilization. This allows the dye laser to be frequency chirped with the maximum 60 GHz scan range while its frequency remains locked. It also offers the advantages of locking at arbitrary dye laser frequencies, having a larger locking capture range and frequency scanning range to be implemented via software. This laser has been developed for the purpose of laser cooling a molecular magnesium fluoride beam.

  20. Absolute parametric instability of low-frequency waves in a 2D ...

    Indian Academy of Sciences (India)

    waves in a 2D nonuniform anisotropic warm plasma. N G ZAKI. Plasma and Nuclear ... describing the parametric exci- tation of surface waves at the boundary of isotropic plasma (vacuum) to within ..... Fifteenth National Radio Science Conference, IEEE Catalog Number 98EX109, ISBN. 0-7803-4310-7, Helwan Univ., Cairo, ...

  1. Absolute parametric instability of low-frequency waves in a 2D ...

    Indian Academy of Sciences (India)

    solved in two-dimensional (2D) nonuniform plane plasma. Equations which describe the spatial part of the electric potential are obtained. Also, the growth rates and conditions of the parametric instability for periodic and aperiodic cases are obtained. It is found that the spatial nonuniformity of the plasma exerts a stabilizing ...

  2. [Assessment of Hepatitis C Virus Diversity in Addition to the Frequency of Genotypes in Samples Analyzed Between 2009 and 2014 at the Reference Laboratory of National Health Institute Dr. Ricardo Jorge].

    Science.gov (United States)

    Pádua, Elizabeth; Avó, Ana Patricia; Almeida, Catarina; Água Doce, Ivone; Cortes Martins, Helena

    2015-01-01

    The identification of genotypes was essential for the prognosis and treatment of hepatitis C virus chronic patients in recent years. The aims of the study were to know the frequency of genotypes diagnosed in the last six years at the laboratory, and reveal the contribution of an in-house assay for molecular characterization of viruses. The genotyping of hepatitis C virus by LiPA was performed in 923 samples, mostly from male individuals. The subtyping of hepatitis C virus by an in-house assay to target regions in the Core/E1 and/or NS5B was performed in 112 samples. We observed a high prevalence of genotype 1 (56.6%), with a frequency of subtype 1a four times higher compared to 1b. All cases of genotype 3 (27.5%) were subtype 3a. For the cases of genotype 4 (12.9%), it were identified subtypes 4a (65.5%), 4d (31%), 4b (1.7%) and 4c (1.7%). Recombinants intragenotype 2, the RF1_2k/1b, and mixed infections, were also identified. The most prevalent subtypes (1a and 3a) obtained are usually described in injecting drug users. Although most of the samples analysed match to inmates (78.4%), we cannot exclude any possible risk behaviors associated with illicit drug use. The high prevalence of subtype 1a, the frequency and diversity of genotype 4, and the identification of recombined virus suggest modification of the molecular pattern of hepatitis C virus infection described in the past. The in-house assay proved to be useful for the correct classification of hepatitis C virus and improving knowledge about the diversity of virus circulating in the country.

  3. Frequency standards

    CERN Document Server

    Riehle, Fritz

    2006-01-01

    Of all measurement units, frequency is the one that may be determined with the highest degree of accuracy. It equally allows precise measurements of other physical and technical quantities, whenever they can be measured in terms of frequency.This volume covers the central methods and techniques relevant for frequency standards developed in physics, electronics, quantum electronics, and statistics. After a review of the basic principles, the book looks at the realisation of commonly used components. It then continues with the description and characterisation of important frequency standards

  4. Prognostic Value of Absolute versus Relative Rise of Blood ...

    African Journals Online (AJOL)

    maternal outcome than a relative rise in the systolic/diastolic blood pressure from mid pregnancy, which did not reach this absolute level. We conclude that in the Nigerian obstetric population, the practice of diagnosing pregnancy hypertension on ...

  5. Efficacy of intrahepatic absolute alcohol in unrespectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Hameed, K.; Khan, I.U.; Shah, S.

    2001-01-01

    To determine efficacy of intrahepatic absolute alcohol injection in researchable hepatocellular carcinoma. A randomized, controlled, experimental and interventional clinical trial. Gastroenterology Department, PGMI, Hayatabad Medical Complex, Peshawar during the period from June, 1998 to June, 2000. Thirty patients were treated by percutaneous, intrahepatic absolute alcohol injection sin repeated sessions, 33 patients were not given or treated with alcohol to serve as control. Both the groups were comparable for age, sex and other baseline characteristics. Absolute alcohol therapy significantly improved quality of life of patients, reduced the tumor size and mortality as well as showed significantly better results regarding survival (P< 0.05) than the patients of control group. We conclude that absolute alcohol is a beneficial and safe palliative treatment measure in advanced hepatocellular carcinoma (HCC). (author)

  6. Changes in Absolute Sea Level Along U.S. Coasts

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map shows changes in absolute sea level from 1960 to 2016 based on satellite measurements. Data were adjusted by applying an inverted barometer (air pressure)...

  7. A 20-40 MHz low-power clock oscillator with open-loop frequency calibration and temperature compensation

    Science.gov (United States)

    Lee, Dongsoo; Kim, Hongjin; Lee, Kang-Yoon

    2014-05-01

    In this paper, a 20-40 MHz low-power clock oscillator is presented to provide the frequency reference in data interface applications. The frequency source is referenced to a frequency-calibrated and temperature-compensated 2.5 GHz LC VCO that is implemented with a bondwire inductor. Class-C type VCO is adopted in order to improve the phase noise and reduce the current consumption. A full digital frequency calibration circuit is proposed to cover the wide output frequency range minimizing the frequency variation. External crystal oscillator (REF_CLK) is used only for the absolute frequency calibration at the initial programming stage and is not needed after the programming stage. On the other hand, temperature compensation is performed in an analogue way by controlling the varactor in the LC VCO. This chip is fabricated using 0.18-µm CMOS with the option of lateral PNP transistor. Lateral PNP transistors are used in the temperature compensation circuits. It can be implemented laterally in standard CMOS process. The power consumption is 4.8 mW from a 1.8 V supply. The accuracy of the frequency is ±58 ppm from -20°C to 80°C. The nominal phase noise at 1 MHz and period jitter is -122 dBc/Hz and 2 ps, respectively, when the output frequency is 25 MHz.

  8. Absolute Continuity of Stable Foliations for Mappings of Banach Spaces

    Science.gov (United States)

    Blumenthal, Alex; Young, Lai-Sang

    2017-09-01

    We prove the absolute continuity of stable foliations for mappings of Banach spaces satisfying conditions consistent with time- t maps of certain classes of dissipative PDEs. This property is crucial for passing information from submanifolds transversal to the stable foliation to the rest of the phase space; it is also used in proofs of ergodicity. Absolute continuity of stable foliations is well known in finite dimensional hyperbolic theory. On Banach spaces, the absence of nice geometric properties poses some additional difficulties.

  9. Single frequency semiconductor lasers

    CERN Document Server

    Fang, Zujie; Chen, Gaoting; Qu, Ronghui

    2017-01-01

    This book systematically introduces the single frequency semiconductor laser, which is widely used in many vital advanced technologies, such as the laser cooling of atoms and atomic clock, high-precision measurements and spectroscopy, coherent optical communications, and advanced optical sensors. It presents both the fundamentals and characteristics of semiconductor lasers, including basic F-P structure and monolithic integrated structures; interprets laser noises and their measurements; and explains mechanisms and technologies relating to the main aspects of single frequency lasers, including external cavity lasers, frequency stabilization technologies, frequency sweeping, optical phase locked loops, and so on. It paints a clear, physical picture of related technologies and reviews new developments in the field as well. It will be a useful reference to graduate students, researchers, and engineers in the field.

  10. Micrometry combined with profile mapping for the absolute measurement of Integrated Column Density (ICD) and for accurate X-ray mass attenuation coefficients using XERT

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M. Tauhidul; Rae, Nicholas A.; Glover, Jack L.; Barnea, Zwi [School of Physics, University of Melbourne, Victoria 3010 (Australia); Chantler, Christopher T., E-mail: chantler@physics.unimelb.edu.a [School of Physics, University of Melbourne, Victoria 3010 (Australia)

    2010-07-21

    Absolute values of the column densities [{rho}t]{sub c} of four gold foils were measured using micrometry combined with the 2D X-ray attenuation profile. The absolute calibration of [{rho}t]{sub c} was made with a reference foil and the [{rho}t]{sub c} of other foils were determined following the thickness transfer method. By this method, we obtain absolute calibration to 0.1% or better which was not possible using only the X-ray map of a single foil over its central region.

  11. Frequency Synthesiser

    NARCIS (Netherlands)

    Drago, Salvatore; Sebastiano, Fabio; Leenaerts, Dominicus M.W.; Breems, Lucien J.; Nauta, Bram

    2016-01-01

    A low power frequency synthesiser circuit (30) for a radio transceiver, the synthesiser circuit comprising: a digital controlled oscillator configured to generate an output signal having a frequency controlled by an input digital control word (DCW); a feedback loop connected between an output and an

  12. Frequency synthesiser

    NARCIS (Netherlands)

    Drago, S.; Sebastiano, Fabio; Leenaerts, Dominicus Martinus Wilhelmus; Breems, Lucien Johannes; Nauta, Bram

    2010-01-01

    A low power frequency synthesiser circuit (30) for a radio transceiver, the synthesiser circuit comprising: a digital controlled oscillator configured to generate an output signal having a frequency controlled by an input digital control word (DCW); a feedback loop connected between an output and an

  13. Distance measurement using frequency-modulated continuous-wave ladar with calibration by a femtosecond frequency comb

    Science.gov (United States)

    Liu, Yang; Yang, Linghui; Lin, Jiarui; Zhu, Jigui

    2018-01-01

    Precise distance measurement is of interest for large-scale manufacturing, future space satellite missions, and other industrial applications. The ranging system with femtosecond optical frequency comb (FOFC) could offer high accuracy, stability and direct traceability to SI definition of the meter. Here, we propose a scheme for length measurement based on the frequency-modulated continuous-wave (FMCW) ladar with a FOFC. In this scheme, the reference interferometer in the FMCW ladar is calibrated by the intensity detection using the FOFC in the time domain within an optical wavelength resolution. With analysis of the theoretical model, this system has the potential to a high-speed, high-accuracy absolute distance measurement. Then, based on the experimental results, the evaluation of the performance of the calibration of the reference arm is discussed. In addition, the performance of this system is evaluated by a single position measurement with different tuning velocities of wavelength. The experimental results show that the reproducibility of the distance measurement is 10-5 level.

  14. Absolute space-time and realism in Lorentz invariant interpretations of quantum mechanics

    Science.gov (United States)

    Combourieu, Marie-Christine; Vigier, Jean-Pierre

    1993-04-01

    The assertion that Lorentz invariance must necessarily be violated in models aimed at giving a realistic account of quantum theory is shown to be incorrect. Assuming that an absolute curved system ofaxes forms the envelope of Local inertial frames where the 2.7 K radiation field as the preferred frame is isotropic, we demonstrate that Lorentz invariance, as well as covariance, stil apply to quantum mechanics in all frames of reference whenever Einstein and de Broglie's theory of light, recently revisited by Vigier [IEEE Trans. Plasma Sci. 18 (1990) 64; in: Proc. ISQM-SAT Conf.], is considered.

  15. A beam position measurement system using quadrupole magnets magnetic centra as the position reference

    International Nuclear Information System (INIS)

    Roejsel, P.

    1994-01-01

    This measurement system uses a method to measure the beam position with high precision in a storage ring with respect to the quadrupole magnets magnetic centra that is used as the absolute position reference. The absolute position of the pickup elements does not affect the beam position measurements so a calibration of the pickup elements absolute position can be done in situ. This paper describes the system, and shows results from a working system at the MAX I storage ring. (orig.)

  16. Electro optic sensor for high precision absolute distance measurement using multiwavelength interferometry.

    Science.gov (United States)

    Sharma, Sucheta; Eiswirt, Peter; Petter, Jürgen

    2018-02-05

    A prototype multi-wavelength interferometric, phase shifting distance sensor based on linear electro optic effect has been demonstrated in this work to improve the measurement speed of a commercial four-wavelength interferometer. Experimental results revealed the phase modulation ability of the sensor, preserving equivalent efficiency for nanometer-scale absolute distance measurement similar to present piezoelectricity driven mechanical phase modulation. The electro optic sensor working under free beam propagation can significantly overcome the limitations experienced by mechanical phase modulation technique such as the restricted value for the modulating frequency and as well the high driving voltage requirement.

  17. Three-dimensional absolute and convective instabilities in mixed convection of a viscoelastic fluid through a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Silvia C. [Laboratoire de Mecanique de Lille, UMR CNRS 8107 - Universite Lille I, Bld. Paul Langevin, 59655 Villeneuve d' Ascq cedex (France); Ouarzazi, Mohamed Najib, E-mail: najib.ouarzazi@univ-lille1.f [Laboratoire de Mecanique de Lille, UMR CNRS 8107 - Universite Lille I, Bld. Paul Langevin, 59655 Villeneuve d' Ascq cedex (France)

    2010-06-07

    By using the mathematical formalism of absolute and convective instabilities we study the nature of unstable three-dimensional disturbances of viscoelastic flow convection in a porous medium with horizontal through-flow and vertical temperature gradient. Temporal stability analysis reveals that among three-dimensional (3D) modes the pure down-stream transverse rolls are favored for the onset of convection. In addition, by considering a spatiotemporal stability approach we found that all unstable 3D modes are convectively unstable except the transverse rolls which may experience a transition to absolute instability. The combined influence of through-flow and elastic parameters on the absolute instability threshold, wave number and frequency is then determined, and results are compared to those of a Newtonian fluid.

  18. Three-dimensional absolute and convective instabilities in mixed convection of a viscoelastic fluid through a porous medium

    International Nuclear Information System (INIS)

    Hirata, Silvia C.; Ouarzazi, Mohamed Najib

    2010-01-01

    By using the mathematical formalism of absolute and convective instabilities we study the nature of unstable three-dimensional disturbances of viscoelastic flow convection in a porous medium with horizontal through-flow and vertical temperature gradient. Temporal stability analysis reveals that among three-dimensional (3D) modes the pure down-stream transverse rolls are favored for the onset of convection. In addition, by considering a spatiotemporal stability approach we found that all unstable 3D modes are convectively unstable except the transverse rolls which may experience a transition to absolute instability. The combined influence of through-flow and elastic parameters on the absolute instability threshold, wave number and frequency is then determined, and results are compared to those of a Newtonian fluid.

  19. Active low-frequency vertical vibration isolation system for precision measurements

    Science.gov (United States)

    Wu, Kang; Li, Gang; Hu, Hua; Wang, Lijun

    2017-01-01

    Low-frequency vertical vibration isolation systems play important roles in precision measurements to reduce seismic and environmental vibration noise. Several types of active vibration isolation systems have been developed. However, few researches focus on how to optimize the test mass install position in order to improve the vibration transmissibility. An active low-frequency vertical vibration isolation system based on an earlier instrument, the Super Spring, is designed and implemented. The system, which is simple and compact, consists of two stages: a parallelogram-shaped linkage to ensure vertical motion, and a simple spring-mass system. The theoretical analysis of the vibration isolation system is presented, including terms erroneously ignored before. By carefully choosing the mechanical parameters according to the above analysis and using feedback control, the resonance frequency of the system is reduced from 2.3 to 0.03 Hz, a reduction by a factor of more than 75. The vibration isolation system is installed as an inertial reference in an absolute gravimeter, where it improved the scatter of the absolute gravity values by a factor of 5. The experimental results verifies the improved performance of the isolation system, making it particularly suitable for precision experiments. The improved vertical vibration isolation system can be used as a prototype for designing high-performance active vertical isolation systems. An improved theoretical model of this active vibration isolation system with beam-pivot configuration is proposed, providing fundamental guidelines for vibration isolator design and assembling.

  20. Absolute Calibration of Si iRMs used for Si Paleo-nutrient proxies

    Science.gov (United States)

    Vocke, Robert; Rabb, Savelas

    2016-04-01

    The Avogadro Project is an ongoing international effort, coordinated by the International Bureau of Weights and Measures (BIPM) and the International Avogadro Coordination (IAC) to redefine the SI unit mole in terms of the Avogadro constant and the SI unit kg in terms of the Planck constant. One of the outgrowths of this effort has been the development of a novel, precise and highly accurate method to measure calibrated (absolute) isotopic ratios that are traceable to the SI (Vocke et al., 2014 Metrologia 51, 361, Azuma et al., 2015 Metrologia 52 360). This approach has also been able to produce absolute Si isotope ratio data with lower levels of uncertainty when compared to the traditional "Atomic Weights" method of absolute isotope ratio measurement. Silicon isotope variations (reported as delta(Si30)and delta(Si29)) in silicic acid dissolved in ocean waters, in biogenic silica and in diatoms are extremely informative paleo-nutrient proxies. The utility and comparability of such measurements however depends on calibration with artifact isotopic Reference Materials (iRMs). We will be reporting new measurements on the iRMs NBS-28 (RM 8546 - Silica Sand), Diatomite, Big Batch and SRM 990 using the Avogadro measurement approach, comparing them with prior assessments of these iRMs.

  1. Absolute Navigation Information Estimation for Micro Planetary Rovers

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2016-03-01

    Full Text Available This paper provides algorithms to estimate absolute navigation information, e.g., absolute attitude and position, by using low power, weight and volume Microelectromechanical Systems-type (MEMS sensors that are suitable for micro planetary rovers. Planetary rovers appear to be easily navigable robots due to their extreme slow speed and rotation but, unfortunately, the sensor suites available for terrestrial robots are not always available for planetary rover navigation. This makes them difficult to navigate in a completely unexplored, harsh and complex environment. Whereas the relative attitude and position can be tracked in a similar way as for ground robots, absolute navigation information, unlike in terrestrial applications, is difficult to obtain for a remote celestial body, such as Mars or the Moon. In this paper, an algorithm called the EASI algorithm (Estimation of Attitude using Sun sensor and Inclinometer is presented to estimate the absolute attitude using a MEMS-type sun sensor and inclinometer, only. Moreover, the output of the EASI algorithm is fused with MEMS gyros to produce more accurate and reliable attitude estimates. An absolute position estimation algorithm has also been presented based on these on-board sensors. Experimental results demonstrate the viability of the proposed algorithms and the sensor suite for low-cost and low-weight micro planetary rovers.

  2. Relative and absolute risk in epidemiology and health physics

    International Nuclear Information System (INIS)

    Goldsmith, R.; Peterson, H.T. Jr.

    1983-01-01

    The health risk from ionizing radiation commonly is expressed in two forms: (1) the relative risk, which is the percentage increase in natural disease rate and (2) the absolute or attributable risk which represents the difference between the natural rate and the rate associated with the agent in question. Relative risk estimates for ionizing radiation generally are higher than those expressed as the absolute risk. This raises the question of which risk estimator is the most appropriate under different conditions. The absolute risk has generally been used for radiation risk assessment, although mathematical combinations such as the arithmetic or geometric mean of both the absolute and relative risks, have also been used. Combinations of the two risk estimators are not valid because the absolute and relative risk are not independent variables. Both human epidemiologic studies and animal experimental data can be found to illustrate the functional relationship between the natural cancer risk and the risk associated with radiation. This implies that the radiation risk estimate derived from one population may not be appropriate for predictions in another population, unless it is adjusted for the difference in the natural disease incidence between the two populations

  3. Comb-referenced frequency-sweeping interferometry for precisely measuring large stepped structures.

    Science.gov (United States)

    Zhang, Weipeng; Wei, Haoyun; Yang, Honglei; Wu, Xuejian; Li, Yan

    2018-02-10

    A precise 3D surface measurement method for large stepped structures without height ambiguity is proposed based on optical-frequency-comb-referenced frequency-sweeping interferometry and Fourier-transformed fractional phase retrieval. Unlike other interferometry that depends on the absolute phase value for several certain wavelengths, this method obtains results from the phase change during frequency sweeping and thus remains free from the confined non-ambiguity range. By reference to an optical frequency comb, the relative uncertainty from the tunable laser frequency was reduced by three orders of magnitude, and the sweeping frequency range can be precisely determined. Besides, the fractional phase can be rapidly retrieved in only one step using a Fourier transform method, with advantages of high accuracy and immunity to light intensity fluctuation and mechanical vibration noise. Samples of step heights from 1 μm to 1 mm were measured, and the standard uncertainty was 45 nm. This permits applications such as quality assurance in microelectronics production and micro-electro-mechanical system (MEMS) manufacture.

  4. Absolute marine gravimetry with matter-wave interferometry.

    Science.gov (United States)

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.

  5. Spatiotemporal Evolution of Stimulated Raman Scattering in the Absolute and Convective Regimes

    International Nuclear Information System (INIS)

    Feng Wu; Li Xibo; Zheng Chunyang

    2013-01-01

    A three-wave interaction (3WI) code is developed to study the stimulated Raman scattering (SRS) in both absolute and convective regimes. In the simulations, the time and spatial evolutions of a plasma wave are described by temporal growth rate and spatial factor, respectively. The spatial factors in different phases and different instability regimes are investigated. It is found that the spatial factor is caused by the finite velocity of the pump wave in the first phase and by damping in the last phase. With inclusion of the spatial factor, the temporal growth rate decreases and the threshold for SRS for a finite frequency mismatch increases. Meanwhile, the effects of wave frequency mismatch on the temporal growth rate are also discussed. (basic plasma phenomena)

  6. Frequency Comparison of [Formula: see text] Ion Optical Clocks at PTB and NPL via GPS PPP.

    Science.gov (United States)

    Leute, J; Huntemann, N; Lipphardt, B; Tamm, Christian; Nisbet-Jones, P B R; King, S A; Godun, R M; Jones, J M; Margolis, H S; Whibberley, P B; Wallin, A; Merimaa, M; Gill, P; Peik, E

    2016-07-01

    We used precise point positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled [Formula: see text] ions operated at the National Physical Laboratory (NPL), U.K. and the Physikalisch-Technische Bundesanstalt (PTB), Germany. At both institutes, an active hydrogen maser serves as a flywheel oscillator which is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the (2)S1/2(F=0)-(2)D3/2(F=2) electric quadrupole transition in [Formula: see text] via an optical femtosecond frequency comb. To profit from long coherent GPS-link measurements, we extrapolate the fractional frequency difference over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS-link instability. We determined the total statistical uncertainty consisting of the GPS-link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference [Formula: see text] of -1.3×10(-15) with a combined uncertainty of 1.2×10(-15) for a total measurement time of 67 h. This result is consistent with an agreement of the frequencies realized by both optical clocks and with recent absolute frequency measurements against caesium fountain clocks within the corresponding uncertainties.

  7. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Directory of Open Access Journals (Sweden)

    Sander K R van Zon

    Full Text Available The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender.The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender.Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups.Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and

  8. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Science.gov (United States)

    van Zon, Sander K R; Bültmann, Ute; Mendes de Leon, Carlos F; Reijneveld, Sijmen A

    2015-01-01

    The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender. The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender. Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups. Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and health outcome

  9. Mapping with MAV: Experimental Study on the Contribution of Absolute and Relative Aerial Position Control

    Science.gov (United States)

    Skaloud, J.; Rehak, M.; Lichti, D.

    2014-03-01

    This study highlights the benefit of precise aerial position control in the context of mapping using frame-based imagery taken by small UAVs. We execute several flights with a custom Micro Aerial Vehicle (MAV) octocopter over a small calibration field equipped with 90 signalized targets and 25 ground control points. The octocopter carries a consumer grade RGB camera, modified to insure precise GPS time stamping of each exposure, as well as a multi-frequency/constellation GNSS receiver. The GNSS antenna and camera are rigidly mounted together on a one-axis gimbal that allows control of the obliquity of the captured imagery. The presented experiments focus on including absolute and relative aerial control. We confirm practically that both approaches are very effective: the absolute control allows omission of ground control points while the relative requires only a minimum number of control points. Indeed, the latter method represents an attractive alternative in the context of MAVs for two reasons. First, the procedure is somewhat simplified (e.g. the lever-arm between the camera perspective and antenna phase centers does not need to be determined) and, second, its principle allows employing a single-frequency antenna and carrier-phase GNSS receiver. This reduces the cost of the system as well as the payload, which in turn increases the flying time.

  10. Mapping with MAV: Experimental Study on the Contribution of Absolute and Relative Aerial Position Control

    Directory of Open Access Journals (Sweden)

    J. Skaloud

    2014-03-01

    Full Text Available This study highlights the benefit of precise aerial position control in the context of mapping using frame-based imagery taken by small UAVs. We execute several flights with a custom Micro Aerial Vehicle (MAV octocopter over a small calibration field equipped with 90 signalized targets and 25 ground control points. The octocopter carries a consumer grade RGB camera, modified to insure precise GPS time stamping of each exposure, as well as a multi-frequency/constellation GNSS receiver. The GNSS antenna and camera are rigidly mounted together on a one-axis gimbal that allows control of the obliquity of the captured imagery. The presented experiments focus on including absolute and relative aerial control. We confirm practically that both approaches are very effective: the absolute control allows omission of ground control points while the relative requires only a minimum number of control points. Indeed, the latter method represents an attractive alternative in the context of MAVs for two reasons. First, the procedure is somewhat simplified (e.g. the lever-arm between the camera perspective and antenna phase centers does not need to be determined and, second, its principle allows employing a single-frequency antenna and carrier-phase GNSS receiver. This reduces the cost of the system as well as the payload, which in turn increases the flying time.

  11. Camera-based speckle noise reduction for 3-D absolute shape measurements.

    Science.gov (United States)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen; Fischer, Andreas

    2016-05-30

    Simultaneous position and velocity measurements enable absolute 3-D shape measurements of fast rotating objects for instance for monitoring the cutting process in a lathe. Laser Doppler distance sensors enable simultaneous position and velocity measurements with a single sensor head by evaluating the scattered light signals. The superposition of several speckles with equal Doppler frequency but random phase on the photo detector results in an increased velocity and shape uncertainty, however. In this paper, we present a novel image evaluation method that overcomes the uncertainty limitations due to the speckle effect. For this purpose, the scattered light is detected with a camera instead of single photo detectors. Thus, the Doppler frequency from each speckle can be evaluated separately and the velocity uncertainty decreases with the square root of the number of camera lines. A reduction of the velocity uncertainty by the order of one magnitude is verified by the numerical simulations and experimental results, respectively. As a result, the measurement uncertainty of the absolute shape is not limited by the speckle effect anymore.

  12. Clinical application of absolute ethanol as an embolizing material

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Chang, Kee Hyun; Han, Man Chung

    1982-01-01

    Transcatheter infusion of absolute ethanol was applied clinically in 3 cases of artificial embolization: 25 yrs old female with bilateral renal angiomyolipoma, 19 yrs old female with right paralumbar liposarcoma and 25 yrs old male with hypernephroma of right kidney. Selective or subselective manual infusion was made and 9 to 22 cc of pure ethanol was delivered in a speed of 1 to 2 cc per second. The sclerosing effect of absolute ethanol was potent. However, all 3 cases revealed mild post-embolization syndrome

  13. Absolute Stability Analysis of a Phase Plane Controlled Spacecraft

    Science.gov (United States)

    Jang, Jiann-Woei; Plummer, Michael; Bedrossian, Nazareth; Hall, Charles; Jackson, Mark; Spanos, Pol

    2010-01-01

    Many aerospace attitude control systems utilize phase plane control schemes that include nonlinear elements such as dead zone and ideal relay. To evaluate phase plane control robustness, stability margin prediction methods must be developed. Absolute stability is extended to predict stability margins and to define an abort condition. A constrained optimization approach is also used to design flex filters for roll control. The design goal is to optimize vehicle tracking performance while maintaining adequate stability margins. Absolute stability is shown to provide satisfactory stability constraints for the optimization.

  14. Absolute gain measurement by the image method under mismatched condition

    Science.gov (United States)

    Lee, Richard Q.; Baddour, Maurice F.

    1987-01-01

    Purcell's image method for measuring the absolute gain of an antenna is particularly attractive for small test antennas. The method is simple to use and utilizes only one antenna with a reflecting plane to provide an image for the receiving antenna. However, the method provides accurate results only if the antenna is matched to its waveguide. In this paper, a waveguide junction analysis is developed to determine the gain of an antenna under mismatched condition. Absolute gain measurements for two standard gain horn antennas have been carried out. Experimental results agree closely with published data.

  15. Absolute and conditional convergence within Sonora state municipalities, 1989- 2004

    Directory of Open Access Journals (Sweden)

    Joaquín Bracamontes Neváre

    2008-07-01

    Full Text Available This paper tries to identify the existence of convergence, absolut as muchas conditional, for the municipalities that conform the state of Sonora. Taking as abase the methodologic excercise of Mankiw, Romer and Weill (1992 that considersthe first model of Solow (1956 and makes an extension of it including thehuman capital, evidence shows that there is no tendency for poor municipalitiesto grow more quickly than rich municipalities, which means that there is no processof convergence –nor absolute or conditional– in the municipalities of Sonora,independently of the development layer in which these are classified: municipalitieswith high, average or low development.

  16. Total synthesis and absolute configuration of the marine norditerpenoid xestenone.

    Science.gov (United States)

    Ota, Koichiro; Kurokawa, Takao; Kawashima, Etsuko; Miyaoka, Hiroaki

    2009-11-24

    Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  17. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  18. Tv & video engineer's reference book

    CERN Document Server

    Jackson, K G

    1991-01-01

    TV & Video Engineer's Reference Book presents an extensive examination of the basic television standards and broadcasting spectrum. It discusses the fundamental concepts in analogue and digital circuit theory. It addresses studies in the engineering mathematics, formulas, and calculations. Some of the topics covered in the book are the conductors and insulators, passive components, alternating current circuits; broadcast transmission; radio frequency propagation; electron optics in cathode ray tube; color encoding and decoding systems; television transmitters; and remote supervision of unatten

  19. Compact precision wavelength reference for O2 sensing at 1.27 um for ASCENDS Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop compact absolute wavelength references to weak molecular transitions, which is a challenge characteristic to space-based active sensing. The...

  20. Frecuencia de tuberculosis pulmonar y extrapulmonar en un hospital de referencia de la provincia de Córdoba: 1991-2003 Frequency of pulmonary and extrapulmonary tuberculosis in a reference hospital in Córdoba province: 1991-2003

    Directory of Open Access Journals (Sweden)

    P.A. Soldá

    2005-06-01

    Full Text Available La tuberculosis continúa siendo un grave problema de salud pública, ocasionando aproximadamente tres millones de muertes anuales en el mundo. A pesar del avance tecnológico en los métodos diagnósticos, no es posible controlar la enfermedad sin programas de vigilancia y seguimiento que supervisen la finalización de los tratamientos y la cura definitiva del paciente. En este trabajo se determinó la frecuencia de casos de tuberculosis pulmonar, extrapulmonar y localización pulmonar y extrapulmonar asociadas, en pacientes que asistieron al Hospital Tránsito Cáceres de Allende en un período de trece años (1991-2003. También se observó el beneficio de sembrar en el medio de Stonebrink para una mayor recuperación de Mycobacterium bovis y se evaluó el aporte de la baciloscopia en los materiales extrapulmonares. Se diagnosticaron 790 casos de tuberculosis, 723 correspondieron a localización pulmonar y 48 a extrapulmonar (pleural 31, renal 7, ganglionar 5, meníngea 2, genital 1, pericárdica 1 y digestiva 1 y 19 a asociación de localización pulmonar y extrapulmonar. De los 723 casos pulmonares, 9 fueron causados por M. bovis; todos desarrollaron en el medio de cultivo de Stonebrink y solamente uno en el medio de Lowenstein Jensen. El examen baciloscópico de las muestras extrapulmonares resultó positivo en cuatro casos.Tuberculosis continues to be a serious problem of public health causing nearly three million deaths per year all over the world. Despite technologic improvements in the diagnostic methods, it is not possible to control the disease in the absence of surveillance and treatment follow-up programs supervising the ending of treatments, and definitive cure of patients. The frequency of pulmonary and extrapulmonary tuberculosis, and simultaneous pulmonary and extrapulmonary tuberculosis localization among patients assisted at Tránsito Cáceres de Allende Hospital during thirteen years (1991-2003, was determined. The benefit

  1. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  2. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    Science.gov (United States)

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  3. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    NARCIS (Netherlands)

    Hernandez, E. M.; Juarez, A. M.; Kilcoyne, A. L. D.; Aguilar, A.; Hernandez, L.; Antillon, A.; Macaluso, D.; Morales-Mori, A.; Gonzalez-Magana, O.; Hanstorp, D.; Covington, A. M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    The photoionization of Cl+ leading to Cl2+ was measured in the photon energy range of 19.5-28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl+ ion beam with a photon beam of

  4. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    Science.gov (United States)

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises,…

  5. Mechanism for an absolute parametric instability of an inhomogeneous plasma

    Science.gov (United States)

    Arkhipenko, V. I.; Budnikov, V. N.; Gusakov, E. Z.; Romanchuk, I. A.; Simonchik, L. V.

    1984-05-01

    The structure of plasma oscillations in a region of parametric spatial amplification has been studied experimentally for the first time. A new mechanism for an absolute parametric instability has been observed. This mechanism operates when a pump wave with a spatial structure more complicated than a plane wave propagates through a plasma which is inhomogeneous along more than one dimension.

  6. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2015-01-01

    The global absolute poverty rates of the World Bank demonstrate a continued decline of poverty in developing countries between 1983 and 2012. However, the methodology applied to derive these results has received extensive criticism by scholars for requiring the application of PPP exchange rates and

  7. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2017-01-01

    The widely applied “dollar-a-day” methodology identifies global absolute poverty as declining precipitously since the early 80’s throughout the developing world. The methodological underpinnings of the “dollar-a-day” approach have been questioned in terms of adequately representing equivalent

  8. An improved generalized Newton method for absolute value equations.

    Science.gov (United States)

    Feng, Jingmei; Liu, Sanyang

    2016-01-01

    In this paper, we suggest and analyze an improved generalized Newton method for solving the NP-hard absolute value equations [Formula: see text] when the singular values of A exceed 1. We show that the global and local quadratic convergence of the proposed method. Numerical experiments show the efficiency of the method and the high accuracy of calculation.

  9. Multipliers for the absolute Euler summability of Fourier series

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    (Math. Sci.), Vol. 111, No. 2, May 2001, pp. 203–219. Printed in India. Multipliers for the absolute Euler summability of Fourier series. PREM CHANDRA. School of Studies in Mathematics, Vikram University, Ujjain 456 010, India. MS received 30 December 1999; revised 30 October 2000. Abstract. In this paper, the author ...

  10. Predicting accurate absolute binding energies in aqueous solution

    DEFF Research Database (Denmark)

    Jensen, Jan Halborg

    2015-01-01

    Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic. In this paper I summarize some of the many factors that could easily contribute 1-3 kcal...

  11. Planck absolute entropy of a rotating BTZ black hole

    Indian Academy of Sciences (India)

    S. M. Jawwad Riaz

    2018-03-06

    Mar 6, 2018 ... Abstract. In this paper, the Planck absolute entropy and the Bekenstein–Smarr formula of the rotating. Banados–Teitelboim–Zanelli (BTZ) black hole are presented via a complex thermodynamical system con- tributed by its inner and outer horizons. The redefined entropy approaches zero as the ...

  12. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  13. 20 CFR 404.1205 - Absolute coverage groups.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Absolute coverage groups. 404.1205 Section 404.1205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY...) Employees of a State's political subdivision performing services in connection with that subdivision's...

  14. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Pie Valls, B; Pietrzyk, B; Pilar, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; du Pree, T; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shao, B; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skottowe, H P; Skwarnicki, T; Smith, A C; Smith, N A; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Styles, N; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Vervink, K; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Voong, D; Vorobyev, A; Voss, H; Wacker, K; Wandernoth, S; Wang, J; Ward, D R; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  15. Dominated operators, absolutely summing operators and the strict ...

    African Journals Online (AJOL)

    b(X;E) be the space of all E-valued bounded continuous functions on X, equipped with the strict topology β. We study dominated and absolutely summing operators T : Cb(X;E) → F. We derive that if X is a locally compact Hausdorff space and E ...

  16. NIST Stars: Absolute Spectrophotometric Calibration of Vega and Sirius

    Science.gov (United States)

    Deustua, Susana; Woodward, John T.; Rice, Joseph P.; Brown, Steven W.; Maxwell, Stephen E.; Alberding, Brian G.; Lykke, Keith R.

    2018-01-01

    Absolute flux calibration of standard stars, traceable to SI (International System of Units) standards, is essential for 21st century astrophysics. Dark energy investigations that rely on observations of Type Ia supernovae and precise photometric redshifts of weakly lensed galaxies require a minimum accuracy of 0.5 % in the absolute color calibration. Studies that aim to address fundamental stellar astrophysics also benefit. In the era of large telescopes and all sky surveys well-calibrated standard stars that do not saturate and that are available over the whole sky are needed. Significant effort has been expended to obtain absolute measurements of the fundamental standards Vega and Sirius (and other stars) in the visible and near infrared, achieving total uncertainties between1% and 3%, depending on wavelength, that do not meet the needed accuracy. The NIST Stars program aims to determine the top-of-the-atmosphere absolute spectral irradiance of bright stars to an uncertainty less than 1% from a ground-based observatory. NIST Stars has developed a novel, fully SI-traceable laboratory calibration strategy that will enable achieving the desired accuracy. This strategy has two key components. The first is the SI-traceable calibration of the entire instrument system, and the second is the repeated spectroscopic measurement of the target star throughout the night. We will describe our experimental strategy, present preliminary results for Vega and Sirius and an end-to-end uncertainty budget

  17. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.

    2011-04-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional support for our model of enantioinduction in the palladium(II)-catalyzed oxidative kinetic resolution of secondary alcohols. © 2010 Elsevier Ltd. All rights reserved.

  18. DESIGN AND CONSTRUCTION OF AN ABSOLUTE GRAVITY METER

    African Journals Online (AJOL)

    An absolute gravimeter which has been designed and constructed consists of a timing circuit which measures the time a body takes to fall between two points separated by a known distance. The time of fall and the known distance are used to calculate the acceleration of gravity at the point of experimentation.

  19. Absolutely continuous spectrum and spectral transition for some ...

    Indian Academy of Sciences (India)

    Absolutely continuous spectrum and spectral transition for some continuous random operators. M KRISHNA. Institute of Mathematical Sciences, Taramani, Chennai 600 113, India. E-mail: krishna@imsc.res.in. MS received 28 February 2010; revised 6 June 2011. Dedicated to Barry Simon for his 65th birthday. Abstract.

  20. Relative versus Absolute Stimulus Control in the Temporal Bisection Task

    Science.gov (United States)

    de Carvalho, Marilia Pinhiero; Machado, Armando

    2012-01-01

    When subjects learn to associate two sample durations with two comparison keys, do they learn to associate the keys with the short and long samples (relational hypothesis), or with the specific sample durations (absolute hypothesis)? We exposed 16 pigeons to an ABA design in which phases A and B corresponded to tasks using samples of 1 s and 4 s,…

  1. Use of absolute lymphocyte count or neutrophil ingestion rate of ...

    African Journals Online (AJOL)

    The present study was designed to evaluate absolute lymphocyte count or neutrophil ingestion rate of NBT as alternative indices to CD4+ T cell count in the management of HIV/AIDS subjects. 158 adult participants (male = 70, female = 88) were recruited for the study and grouped as: (i) Symptomatic HIV subjects with or ...

  2. Necessity and sufficiency conditions for the absolute null ...

    African Journals Online (AJOL)

    We are inspired by the works of Chukwu [1], Eke [2], Schinterdorf and Barmish [4] to unveil necessary and sufficient conditions for the absolute null controllability of a linear delay perturbed system with zero in the domain of null controllability. Journal of the Nigerian Association of Mathematical Physics Vol. 10 2006: pp. 549- ...

  3. Absolute Stability of Discrete-Time Systems with Delay

    Directory of Open Access Journals (Sweden)

    Medina Rigoberto

    2008-01-01

    Full Text Available We investigate the stability of nonlinear nonautonomous discrete-time systems with delaying arguments, whose linear part has slowly varying coefficients, and the nonlinear part has linear majorants. Based on the "freezing" technique to discrete-time systems, we derive explicit conditions for the absolute stability of the zero solution of such systems.

  4. DOES ABSOLUTE SYNONYMY EXIST IN OWERE-IGBO?

    African Journals Online (AJOL)

    USER

    or emotional overtones, etc. These are explained below: A. Contextual Differences: One of the implications of absolute synonymy is that it must be possible for synonyms to be used interchangeably in all sentence contexts. But our analyses of the sentences above as given by native speakers indicated that there are some ...

  5. The Absolute and the Relative Dimensions of Constitutional Rights

    Czech Academy of Sciences Publication Activity Database

    Alexy, Robert

    2017-01-01

    Roč. 37, č. 1 (2017), s. 31-47 ISSN 0143-6503 Keywords : constitutional rights * judicial review * proportionality Subject RIV: AG - Legal Sciences OBOR OECD: Law Impact factor: 1.242, year: 2016 https://academic.oup.com/ojls/article/37/1/31/2669583/The-Absolute-and-the-Relative-Dimensions-of

  6. Absolute intensity calibration for ECE measurements on EAST

    International Nuclear Information System (INIS)

    Liu Yong; Liu Xiang; Zhao Hailin

    2014-01-01

    In this proceeding, the results of the in-situ absolute intensity calibration for ECE measurements on EAST are presented. A 32-channel heterodyne radiometer system and a Michelson interferometer on EAST have been calibrated independently, and preliminary results from plasma operation indicate a good agreement between the electron temperature profiles obtained with different systems. (author)

  7. Fabricating the absolute fake: America in contemporary pop culture

    NARCIS (Netherlands)

    Kooijman, J.

    2008-01-01

    Onze wereld wordt gedomineerd door de Amerikaanse popcultuur. Fabricating the Absolute Fake onderzoekt de dynamiek van Amerikanisering aan de hand van hedendaagse films, televisieprogramma's en popsterren die reflecteren op de vraag wat het betekent om Amerikaan in een mondiale popcultuur te zijn.

  8. On quantum harmonic oscillator being subjected to absolute ...

    Indian Academy of Sciences (India)

    On quantum harmonic oscillator being subjected to absolute potential state. SWAMI NITYAYOGANANDA. Ramakrishna Mission Ashrama, R.K. Beach, Visakhapatnam 530 003, India. E-mail: nityayogananda@gmail.com. MS received 1 May 2015; accepted 6 May 2016; published online 3 December 2016. Abstract.

  9. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the ∑ n ≤ N f(n)$ with explicit error term. As a corollary we obtain new results about sum-of-divisors functions and Jordan's totient functions.

  10. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    , Chennai 600 113, India. E-mail: biswajyoti@imsc.res.in. MS received 9 May 2015; revised 9 July 2015. Abstract. For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the sum. ∑.

  11. Standardization approaches in absolute quantitative proteomics with mass spectrometry.

    Science.gov (United States)

    Calderón-Celis, Francisco; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo

    2017-07-31

    Mass spectrometry-based approaches have enabled important breakthroughs in quantitative proteomics in the last decades. This development is reflected in the better quantitative assessment of protein levels as well as to understand post-translational modifications and protein complexes and networks. Nowadays, the focus of quantitative proteomics shifted from the relative determination of proteins (ie, differential expression between two or more cellular states) to absolute quantity determination, required for a more-thorough characterization of biological models and comprehension of the proteome dynamism, as well as for the search and validation of novel protein biomarkers. However, the physico-chemical environment of the analyte species affects strongly the ionization efficiency in most mass spectrometry (MS) types, which thereby require the use of specially designed standardization approaches to provide absolute quantifications. Most common of such approaches nowadays include (i) the use of stable isotope-labeled peptide standards, isotopologues to the target proteotypic peptides expected after tryptic digestion of the target protein; (ii) use of stable isotope-labeled protein standards to compensate for sample preparation, sample loss, and proteolysis steps; (iii) isobaric reagents, which after fragmentation in the MS/MS analysis provide a final detectable mass shift, can be used to tag both analyte and standard samples; (iv) label-free approaches in which the absolute quantitative data are not obtained through the use of any kind of labeling, but from computational normalization of the raw data and adequate standards; (v) elemental mass spectrometry-based workflows able to provide directly absolute quantification of peptides/proteins that contain an ICP-detectable element. A critical insight from the Analytical Chemistry perspective of the different standardization approaches and their combinations used so far for absolute quantitative MS-based (molecular and

  12. Symmetry, Reference Frames, and Relational Quantities in Quantum Mechanics

    Science.gov (United States)

    Loveridge, Leon; Miyadera, Takayuki; Busch, Paul

    2018-02-01

    We propose that observables in quantum theory are properly understood as representatives of symmetry-invariant quantities relating one system to another, the latter to be called a reference system. We provide a rigorous mathematical language to introduce and study quantum reference systems, showing that the orthodox "absolute" quantities are good representatives of observable relative quantities if the reference state is suitably localised. We use this relational formalism to critique the literature on the relationship between reference frames and superselection rules, settling a long-standing debate on the subject.

  13. A fiducial reference site for satellite altimetry in Crete, Greece

    DEFF Research Database (Denmark)

    Mertikas, Stelios; Donlon, Craig; Mavrokordatos, Constantin

    With the advent of diverse satellite altimeters and variant measuring techniques, it has become mature in the scientific community, that an absolute reference Cal/Val site is regularly maintained to define, monitor, control the responses of any altimetric system. This work sets the ground for the...

  14. Quantification of silane molecules on oxidized silicon: are there options for a traceable and absolute determination?

    Science.gov (United States)

    Dietrich, P M; Streeck, C; Glamsch, S; Ehlert, C; Lippitz, A; Nutsch, A; Kulak, N; Beckhoff, B; Unger, W E S

    2015-10-06

    Organosilanes are used routinely to functionalize various support materials for further modifications. Nevertheless, reliable quantitative information about surface functional group densities after layer formation is rarely available. Here, we present the analysis of thin organic nanolayers made from nitrogen containing silane molecules on naturally oxidized silicon wafers with reference-free total reflection X-ray fluorescence (TXRF) and X-ray photoelectron spectroscopy (XPS). An areic density of 2-4 silane molecules per nm(2) was calculated from the layer's nitrogen mass deposition per area unit obtained by reference-free TXRF. Complementary energy and angle-resolved XPS (ER/AR-XPS) in the Si 2p core-level region was used to analyze the outermost surface region of the organic (silane layer)-inorganic (silicon wafer) interface. Different coexisting silicon species as silicon, native silicon oxide, and silane were identified and quantified. As a result of the presented proof-of-concept, absolute and traceable values for the areic density of silanes containing nitrogen as intrinsic marker are obtained by calibration of the XPS methods with reference-free TXRF. Furthermore, ER/AR-XPS is shown to facilitate the determination of areic densities in (mono)layers made from silanes having no heteroatomic marker other than silicon. After calibration with reference-free TXRF, these areic densities of silane molecules can be determined when using the XPS component intensity of the silane's silicon atom.

  15. Absolute spectroscopy near 7.8 {\\mu} m with a comb-locked extended-cavity quantum-cascade-laser

    KAUST Repository

    Lamperti, Marco

    2017-07-31

    We report the first experimental demonstration of frequency-locking of an extended-cavity quantum-cascade-laser (EC-QCL) to a near-infrared frequency comb. The locking scheme is applied to carry out absolute spectroscopy of N2O lines near 7.87 {\\\\mu}m with an accuracy of ~60 kHz. Thanks to a single mode operation over more than 100 cm^{-1}, the comb-locked EC-QCL shows great potential for the accurate retrieval of line center frequencies in a spectral region that is currently outside the reach of broadly tunable cw sources, either based on difference frequency generation or optical parametric oscillation. The approach described here can be straightforwardly extended up to 12 {\\\\mu}m, which is the current wavelength limit for commercial cw EC-QCLs.

  16. The HST Large Programme on ω Centauri. III. Absolute Proper Motion

    Science.gov (United States)

    Libralato, Mattia; Bellini, Andrea; Bedin, Luigi R.; Moreno D., Edmundo; Fernández-Trincado, José G.; Pichardo, Barbara; van der Marel, Roeland P.; Anderson, Jay; Apai, Dániel; Burgasser, Adam J.; Fabiola Marino, Anna; Milone, Antonino P.; Rees, Jon M.; Watkins, Laura L.

    2018-02-01

    In this paper, we report a new estimate of the absolute proper motion (PM) of the globular cluster NGC 5139 (ω Cen) as part of the HST large program GO-14118+14662. We analyzed a field 17 arcmin southwest of the center of ω Cen and computed PMs with epoch spans of ∼15.1 years. We employed 45 background galaxies to link our relative PMs to an absolute reference-frame system. The absolute PM of the cluster in our field is ({μ }α \\cos δ ,{μ }δ )=(-3.341+/- 0.028,-6.557+/- 0.043) mas yr‑1. Upon correction for the effects of viewing perspective and the known cluster rotation, this implies that for the cluster center of mass ({μ }α \\cos δ ,{μ }δ )=(-3.238+/- 0.028,-6.716+/- 0.043) mas yr‑1. This measurement is direct and independent, has the highest random and systematic accuracy to date, and will provide an external verification for the upcoming Gaia Data Release 2. It also differs from most reported PMs for ω Cen in the literature by more than 5σ, but consistency checks compared to other recent catalogs yield excellent agreement. We computed the corresponding Galactocentric velocity, calculated the implied orbit of ω Cen in two different Galactic potentials, and compared these orbits to the orbits implied by one of the PM measurements available in the literature. We find a larger (by about 500 pc) perigalactic distance for ω Cen with our new PM measurement, suggesting a larger survival expectancy for the cluster in the Galaxy.

  17. Simulation and analysis of spectroscopic filter of rotational Raman lidar for absolute measurement of atmospheric temperature

    Science.gov (United States)

    Li, Qimeng; Li, Shichun; Hu, Xianglong; Zhao, Jing; Xin, Wenhui; Song, Yuehui; Hua, Dengxin

    2018-01-01

    The absolute measurement technique for atmospheric temperature can avoid the calibration process and improve the measurement accuracy. To achieve the rotational Raman temperature lidar of absolute measurement, the two-stage parallel multi-channel spectroscopic filter combined a first-order blazed grating with a fiber Bragg grating is designed and its performance is tested. The parameters and the optical path structure of the core cascaded-device (micron-level fiber array) are optimized, the optical path of the primary spectroscope is simulated and the maximum centrifugal distortion of the rotational Raman spectrum is approximately 0.0031 nm, the centrifugal ratio of 0.69%. The experimental results show that the channel coefficients of the primary spectroscope are 0.67, 0.91, 0.67, 0.75, 0.82, 0.63, 0.87, 0.97, 0.89, 0.87 and 1 by using the twelfth channel as a reference and the average FWHM is about 0.44 nm. The maximum deviation between the experimental wavelength and the theoretical value is approximately 0.0398 nm, with the deviation degree of 8.86%. The effective suppression to elastic scattering signal are 30.6, 35.2, 37.1, 38.4, 36.8, 38.2, 41.0, 44.3, 44.0, 46.7 dB. That means, combined with the second spectroscope, the suppression at least is up to 65 dB. Therefore we can fine extract single rotational Raman line to achieve the absolute measurement technique.

  18. Absolute choline concentration measured by quantitative proton MR spectroscopy correlates with cell density in meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Qiang [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan)]|[West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China); Shibata, Yasushi; Kawamura, Hiraku; Matsumura, Akira [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan); Isobe, Tomonori [Kitasato University, Department of Medical Technology, School of Allied Health Sciences, Minato, Tokyo (Japan); Anno, Izumi [University of Tsukuba, Department of Radiology, Institute of Clinical Medicine, Tsukuba, Ibaraki (Japan); Gong, Qi-Yong [West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China)]|[University of Liverpool, Division of Medical Imaging, Faculty of Medicine, Liverpool (United Kingdom)

    2009-01-15

    This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Average Cho concentration of all meningiomas before correction was 2.95 {+-} 0.86 mmol/kg wet weight. It was increased to 3.23 {+-} 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 {+-} 119 cells/HPF, and average proliferation index was 2.93 {+-} 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. (orig.)

  19. Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.

    2017-09-01

    The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.

  20. Inversion of Multi-Station Schumann Resonance Background Records for Global Lightning Activity in Absolute Units

    Science.gov (United States)

    Williams, E. R.; Mushtak, V. C.; Guha, A.; Boldi, R. A.; Bor, J.; Nagy, T.; Satori, G.; Sinha, A. K.; Rawat, R.; Hobara, Y.; Sato, M.; Takahashi, Y.; Price, C. G.; Neska, M.; Alexander, K.; Yampolski, Y.; Moore, R. C.; Mitchell, M. F.; Fraser-Smith, A. C.

    2014-12-01

    Every lightning flash contributes energy to the TEM mode of the natural global waveguide that contains the Earth's Schumann resonances. The modest attenuation at ELF (0.1 dB/Mm) allows for the continuous monitoring of the global lightning with a small number of receiving stations worldwide. In this study, nine ELF receiving sites (in Antarctica (3 sites), Hungary, India, Japan, Poland, Spitsbergen and USA) are used to provide power spectra at 12-minute intervals in two absolutely calibrated magnetic fields and occasionally, one electric field, with up to five resonance modes each. The observables are the extracted modal parameters (peak intensity, peak frequency and Q-factor) for each spectrum. The unknown quantities are the geographical locations of three continental lightning 'chimneys' and their lightning source strengths in absolute units (C2 km2/sec). The unknowns are calculated from the observables by the iterative inversion of an evolving 'sensitivity matrix' whose elements are the partial derivatives of each observable for all receiving sites with respect to each unknown quantity. The propagation model includes the important day-night asymmetry of the natural waveguide. To overcome the problem of multiple minima (common in inversion problems of this kind), location information from the World Wide Lightning Location Network has been used to make initial guess solutions based on centroids of stroke locations in each chimney. Results for five consecutive days in 2009 (Jan 7-11) show UT variations with the African chimney dominating on four of five days, and America dominating on the fifth day. The amplitude variations in absolute source strength exceed that of the 'Carnegie curve' of the DC global circuit by roughly twofold. Day-to-day variations in chimney source strength are of the order of tens of percent. Examination of forward calculations performed with the global inversion solution often show good agreement with the observed diurnal variations at

  1. Henry More and the development of absolute time.

    Science.gov (United States)

    Thomas, Emily

    2015-12-01

    This paper explores the nature, development and influence of the first English account of absolute time, put forward in the mid-seventeenth century by the 'Cambridge Platonist' Henry More. Against claims in the literature that More does not have an account of time, this paper sets out More's evolving account and shows that it reveals the lasting influence of Plotinus. Further, this paper argues that More developed his views on time in response to his adoption of Descartes' vortex cosmology and cosmogony, providing new evidence of More's wider project to absorb Cartesian natural philosophy into his Platonic metaphysics. Finally, this paper argues that More should be added to the list of sources that later English thinkers - including Newton and Samuel Clarke - drew on in constructing their absolute accounts of time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Absolute gravimetry - for monitoring climate change and geodynamics in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil

    be detected in Greenland, resulting from the loading and unloading of ice during winter and summer. Besides this kind of elastic signal, there will also be a more general trend due to the development of the ice. As already indicated, the two geophysical signals under investigation give rise to a vertical...... with the GPS data, it is possible to separate the different signals. The method used in this study is absolute gravimetry. An absolute gravimeter of the A10 type has been purchased by DTU Space for this purpose. This instrument can measure gravity changes as small as 6µGal (= 60nm=s2), which provides...... investigated with different processing methods. These preliminary results of the gravity measurements in Greenland are interesting new data which suggest that as more measurements become available it will be possible, along with the GPS data, to separate the different geodynamical processes and thereby give...

  3. Synesthesia and rhythm. The road to absolute cinema

    Directory of Open Access Journals (Sweden)

    Ricardo Roncero Palomar

    2017-05-01

    Full Text Available Absolute cinema, developed during the historical avant-garde, con-tinued with a long artistic tradition that linked musical with visual experience. Due to cinema as médium of expression, this filmmakers were able to work with the moving image to develop concepts such as rhythm, also with more complex figures than the colored spots that other devices could create at those time. This study starts with the published texts in 1704 by Newton about color, and provides an overview of those artistic highlights that link image and sound, and which creates the origins of absolute cinema. The connections and equivalences between the visual and sound experiences used by these filmmakers are also studied in order to know if there was a continuous line with the origins of these studies or if there was a rupture and other later investigations were able to have more repercussion in their works.

  4. Absolute configuration assignment of (+)-fluralaner using vibrational circular dichroism.

    Science.gov (United States)

    Kong, John; Joyce, Leo A; Liu, Jinchu; Jarrell, Tiffany M; Culberson, J Chris; Sherer, Edward C

    2017-12-01

    The absolute configurations of the separated enantiomers of fluralaner, a racemic animal health product used to prevent fleas and ticks, have been assigned using vibrational circular dichroism (VCD). The crystallographic structure of the active enantiomer (+)-fluralaner has previously been shown to have the (S) configuration using small molecule crystallography. We sought a faster analytical method to determine the absolute configuration of the separated enantiomers. When comparing the measured IR (infrared) and VCD spectra, it is apparent that the amide carbonyl groups appear in the IR but are nearly absent in the VCD. Computational work to calculate the VCD and IR using in vacuo models, implicit solvation, and explicitly solvated complexes has implicated conformational averaging of the carbonyl VCD intensities. © 2017 Wiley Periodicals, Inc.

  5. Absolute efficiencies of X-ray screens for fluoroscopy

    International Nuclear Information System (INIS)

    Giakoumakis, G.E.

    1989-01-01

    The absolute X-ray efficiencies of phosphor screens made of various materials (ZnCdS:Ag, CsI:Na, Y 2 O 2 S:Tb, Gd 2 O 2 S:Tb, CaWO 4 and ZnS:Cu) are reported. The measurements have been carried out under fluoroscopic conditions for tube voltages ranging from 50 to 250 kV and for screen weights from 20 to 200 mg cm -2 . There is also, for comparison, a set of measurements concerning the behaviour of the screens under soft X-rays (20-50 kV) excitation. All the experimental results are discussed on the basis of an improved Hammaker-Ludwig model and analytical expressions are presented permitting the theoretical calculation of the absolute efficiency of the screens. (author)

  6. Absolute dating of the Aegean Late Bronze Age

    International Nuclear Information System (INIS)

    Warren, P.M.

    1987-01-01

    A recent argument for raising the absolute date of the beginning of the Aegean Late Bronze (LB) Age to about 1700 B.C. is critically examined. It is argued here that: (1) the alabaster lid from Knossos did have the stratigraphical context assigned to it by Evans, in all probability Middle Minoan IIIA, c. 1650 B.C.; (2) the attempt to date the alabastron found in an early Eighteenth Dynasty context at Aniba to Late Minoan IIIA:1 is open to objections; (3) radiocarbon dates from Aegean LB I contexts are too wide in their calibrated ranges and too inconsistent both within and between site sets to offer any reliable grounds at present for raising Aegean LB I absolute chronology to 1700 B.C. Other evidence, however, suggests this period began about 1600 B.C., i.e. some fifty years earlier than the conventional date of 1550 B.C. (author)

  7. Absolute limit on rotation of gravitationally bound stars

    Science.gov (United States)

    Glendenning, N. K.

    1994-03-01

    The authors seek an absolute limit on the rotational period for a neutron star as a function of its mass, based on the minimal constraints imposed by Einstein's theory of relativity, Le Chatelier's principle, causality, and a low-density equation of state, uncertainties which can be evaluated as to their effect on the result. This establishes a limiting curve in the mass-period plane below which no pulsar that is a neutron star can lie. For example, the minimum possible Kepler period, which is an absolute limit on rotation below which mass-shedding would occur, is 0.33 ms for a M = 1.442 solar mass neutron star (the mass of PSR1913+16). If the limit were found to be broken by any pulsar, it would signal that the confined hadronic phase of ordinary nucleons and nuclei is only metastable.

  8. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  9. Absolute scale-based imaging position encoder with submicron accuracy

    Science.gov (United States)

    Anisimov, Andrey G.; Pantyushin, Anton V.; Lashmanov, Oleg U.; Vasilev, A. S.; Timofeev, Alexander N.; Korotaev, Valery V.; Gordeev, Sergey V.

    2013-04-01

    Study is devoted to experimental research and development of absolute imaging position encoder based on standard calibrated scale of invar alloy with 1 mm spacing. The encoder uses designed imaging system as a vernier and absolute magnetic encoder as a rough indication. The features of optical design, choice and use of imaging system as long as indexes images processing algorithm are described. A shadow method was implemented: indexes images on a CCD array are formed by the lens focused at the scale surface; the laser module lights up the scale through a beam-splitting prism by a parallel beam. Further dark indexes images on a light scale background are detected and analyzed to estimate the encoder position. Full range of experimental tests was set to calibrate the encoder and to estimate the accuracy. As a result, accuracy close to 1 μm at 1 m was achieved.

  10. ABSOLUTE AND COMPARATIVE SUSTAINABILITY OF FARMING ENTERPRISES IN BULGARIA

    Directory of Open Access Journals (Sweden)

    H. Bachev

    2017-04-01

    Full Text Available Evaluating absolute and comparative sustainability of farming enterprises is among the most topical issues for researchers, farmers, investors, administrators, politicians, interests groups and public at large. Nevertheless, in Bulgaria and most East European countries there are no comprehensive assessments on sustainability level of Bulgarian farms of different juridical type. This article applies a holistic framework and assesses absolute and comparative sustainability major farming structures in Bulgaria - unregistered farms of Natural Persons, Sole Traders, Cooperatives, and Companies. First, method of the study is outlined, and overall characteristics of surveyed farming enterprises presented. After that an assessment is made of integral, governance, economic, social, environmental sustainability of farming structures of different juridical type. Next, structure of farming enterprises with different sustainability levels is analyzed. Finally, conclusion from the study and directions for further research and amelioration of sustainability assessments suggested.

  11. 2002 reference document; Document de reference 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  12. Single and multispecies reference points for Baltic fish stocks

    DEFF Research Database (Denmark)

    Gislason, Henrik

    1999-01-01

    Single and multispecies models are used to examine the effect of species interaction on biological reference points for cod, herring, and sprat in the Baltic. The results demonstrate that reference points are different in single and multispecies contexts. Reference points for fishing mortality...... based on single-species yield and SSB calculations are difficult to use when natural mortality depends on the absolute abundance of the predators and their alternative prey. Reference points based on maximizing total yield from the system may lead to impractical results when species interact...... reference points. Management advice based on biomass reference points will also differ. In the single species situation the combinations of cod and pelagic fishing effort for which the equilibrium spawning- stock biomass of the three species is above the biomass reference points forms a rectangular area...

  13. Absolute bunch length measurements by incoherent radiation fluctuation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Stupakov, Gennady; Zolotorev, Max; Filippetto, Daniele; Jagerhofer, Lukas

    2008-09-29

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  14. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; /LBL, Berkeley; Stupakov, G.V.; /SLAC; Zolotorev, M.S.; /LBL, Berkeley; Filippetto, D.; /INFN, Rome; Jagerhofer, L.; /Vienna, Tech. U.

    2009-12-09

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  15. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  16. Purely absolutely continuous spectrum for almost Mathieu operators

    International Nuclear Information System (INIS)

    Chulaevsky, V.; Delyon, F.

    1989-01-01

    Using a recent result of Sinai, the authors prove that the almost Mathieu operators acting on l 2 (Z), (H αλ Psi)(n) = Ψ(n + 1) + Ψ(n - 1) + λ cos(ωn + α) Ψ(n), have a purely absolutely continuous spectrum for almost all α provided that ω is a good irrational and λ is sufficiently small. Furthermore, the generalized eigenfunctions are quasiperiodic

  17. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    International Nuclear Information System (INIS)

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1 rc covering ∼2600-3300 A after removing optical light, and u ∼ 3000-4000 A) compared to a mid-UV filter (uvm2 ∼2000-2400 A). The uvw1 rc - b colors show a scatter of ∼0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, ∼1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  18. Decreasing Absolute Risk Aversion and Option Pricing Bounds

    OpenAIRE

    Antonella Basso; Paolo Pianca

    1997-01-01

    In this paper efficient bounds for the price of a call option are obtained using the decreasing absolute risk aversion (DARA) dominance rule. Such lower and upper bounds are obtained minimizing and maximizing, respectively, the objective function of a nonlinear optimization problem. An explicit formula (related to an exponential utility function) is given for the special case of three states of nature. A large number of experiments have been carried out and the numerical results support the c...

  19. On the Plane Geometry with Generalized Absolute Value Metric

    Directory of Open Access Journals (Sweden)

    A. Bayar

    2008-01-01

    Full Text Available Metric spaces are among the most important widely studied topics in mathematics. In recent years, Mathematicians began to investigate using other metrics different from Euclidean metric. These metrics also find their place computer age in addition to their importance in geometry. In this paper, we consider the plane geometry with the generalized absolute value metric and define trigonometric functions and norm and then give a plane tiling example for engineers underlying Schwarz's inequality in this plane.

  20. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  1. Absolute Pitch: Effects of Timbre on Note-Naming Ability

    OpenAIRE

    Vanzella, Patr?cia; Schellenberg, E. Glenn

    2010-01-01

    Background Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP poss...

  2. Blastic plasmacytoid dendritic cell neoplasm with absolute monocytosis at presentation

    Directory of Open Access Journals (Sweden)

    Jaworski JM

    2015-02-01

    Full Text Available Joseph M Jaworski,1,2 Vanlila K Swami,1 Rebecca C Heintzelman,1 Carrie A Cusack,3 Christina L Chung,3 Jeremy Peck,3 Matthew Fanelli,3 Micheal Styler,4 Sanaa Rizk,4 J Steve Hou1 1Department of Pathology and Laboratory Medicine, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 2Department of Pathology, Mercy Fitzgerald Hospital, Darby, PA, USA; 3Department of Dermatology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 4Department of Hematology/Oncology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Blastic plasmacytoid dendritic cell neoplasm is an uncommon malignancy derived from precursors of plasmacytoid dendritic cells. Nearly all patients present initially with cutaneous manifestations, with many having extracutaneous disease additionally. While response to chemotherapy initially is effective, relapse occurs in most, with a leukemic phase ultimately developing. The prognosis is dismal. While most of the clinical and pathologic features are well described, the association and possible prognostic significance between peripheral blood absolute monocytosis (>1.0 K/µL and blastic plasmacytoid dendritic cell neoplasm have not been reported. We report a case of a 68-year-old man who presented with a rash for 4–5 months. On physical examination, there were multiple, dull-pink, indurated plaques on the trunk and extremities. Complete blood count revealed thrombocytopenia, absolute monocytosis of 1.7 K/µL, and a negative flow cytometry study. Biopsy of an abdominal lesion revealed typical features of blastic plasmacytoid dendritic cell neoplasm. Patients having both hematologic and nonhematologic malignancies have an increased incidence of absolute monocytosis. Recent studies examining Hodgkin and non-Hodgkin lymphoma patients have suggested that this is a negative prognostic factor. The association between

  3. Absolute Stock Returns and Trading Volumes: Psychological Insights

    Directory of Open Access Journals (Sweden)

    Andrey Kudryavtsev

    2017-07-01

    Full Text Available The present study explores the effect of anchoring on stock trading volumes. I hypothesize that if on the days when the market index rises (falls, a given stock's return is higher (lower than the market return, potentially perceived as a psychological "anchor", then investors may treat that as a salient event and subsequently increase their trading activity in the stock. Employing a large sample of daily price and trading volume data, I find support for this hypothesis, documenting that average abnormal daily stock trading volumes are significantly higher on the days when absolute daily stock returns are higher than the contemporaneous absolute market returns. This effect is found to be stronger on the days of negative stock and market returns, suggesting that on these days, investors are probably more inclined to treat the market returns as anchors when making their trading decisions. The effect remains significant after controlling for other potentially influential factors, including contemporaneous and lagged actual and absolute stock and market returns, historical stock returns and volatilities, and company-specific events, like earnings announcements and dividend payments.

  4. A vibration correction method for free-fall absolute gravimeters

    Science.gov (United States)

    Qian, J.; Wang, G.; Wu, K.; Wang, L. J.

    2018-02-01

    An accurate determination of gravitational acceleration, usually approximated as 9.8 m s-2, has been playing an important role in the areas of metrology, geophysics, and geodetics. Absolute gravimetry has been experiencing rapid developments in recent years. Most absolute gravimeters today employ a free-fall method to measure gravitational acceleration. Noise from ground vibration has become one of the most serious factors limiting measurement precision. Compared to vibration isolators, the vibration correction method is a simple and feasible way to reduce the influence of ground vibrations. A modified vibration correction method is proposed and demonstrated. A two-dimensional golden section search algorithm is used to search for the best parameters of the hypothetical transfer function. Experiments using a T-1 absolute gravimeter are performed. It is verified that for an identical group of drop data, the modified method proposed in this paper can achieve better correction effects with much less computation than previous methods. Compared to vibration isolators, the correction method applies to more hostile environments and even dynamic platforms, and is expected to be used in a wider range of applications.

  5. Bio-Inspired Stretchable Absolute Pressure Sensor Network.

    Science.gov (United States)

    Guo, Yue; Li, Yu-Hung; Guo, Zhiqiang; Kim, Kyunglok; Chang, Fu-Kuo; Wang, Shan X

    2016-01-02

    A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4'' wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles.

  6. Philosophy as Inquiry Aimed at the Absolute Knowledge

    Directory of Open Access Journals (Sweden)

    Ekaterina Snarskaya

    2017-09-01

    Full Text Available Philosophy as the absolute knowledge has been studied from two different but closely related approaches: historical and logical. The first approach exposes four main stages in the history of European metaphysics that marked out types of “philosophical absolutism”: the evolution of philosophy brought to light metaphysics of being, method, morals and logic. All of them are associated with the names of Aristotle, Bacon/Descartes, Kant and Hegel. Then these forms are considered in the second approach that defined them as subject-matter of philosophy as such. Due to their overall, comprehensive character, the focus of philosophy on them justifies its claim on absoluteness as far as philosophy is aimed at comprehension of the world’s unity regardless of the philosopher’s background, values and other preferences. And that is its prerogative since no other form of consciousness lays down this kind of aim. Thus, philosophy is defined as an everlasting attempt to succeed in conceiving the world in all its multifold manifestations. This article is to try to clarify the claim of philosophy on the absolute knowledge.

  7. Use of intensity quotients and differences in absolute structure refinement

    International Nuclear Information System (INIS)

    Parsons, Simon; Flack, Howard D.; Wagner, Trixie

    2013-01-01

    Differences and quotients can be defined using Friedel pairs of reflections and applied in refinement to enable absolute structure to be determined precisely even for light atom crystal structures. Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement

  8. Absolutely minimal extensions of functions on metric spaces

    International Nuclear Information System (INIS)

    Milman, V A

    1999-01-01

    Extensions of a real-valued function from the boundary ∂X 0 of an open subset X 0 of a metric space (X,d) to X 0 are discussed. For the broad class of initial data coming under discussion (linearly bounded functions) locally Lipschitz extensions to X 0 that preserve localized moduli of continuity are constructed. In the set of these extensions an absolutely minimal extension is selected, which was considered before by Aronsson for Lipschitz initial functions in the case X 0 subset of R n . An absolutely minimal extension can be regarded as an ∞-harmonic function, that is, a limit of p-harmonic functions as p→+∞. The proof of the existence of absolutely minimal extensions in a metric space with intrinsic metric is carried out by the Perron method. To this end, ∞-subharmonic, ∞-superharmonic, and ∞-harmonic functions on a metric space are defined and their properties are established

  9. Absolute activity determination of I-125 in the thyroid

    International Nuclear Information System (INIS)

    Pelled, O.; German, U.; Kol, R.; Levinson, S.; Laichter, Y.

    1997-01-01

    I-125 has been widely used in nuclear medicine and as a tracer in different experiments. The dose equivalent to the thyroid Tom internal contamination of 1-125, can be estimated by in-vivo monitoring of the thyroid or through bioassay of urine . The in-vivo monitoring of the thyroid can be carried out by counting the photon emission from the decay of the 1-125 , by a Nal(Tl) detector calibrated with a thyroid phantom. This direct method is sensitive , but due to the low photon energy (27keV to 35keV), the counting efficiency depends strongly on the variations of the thyroid mass , thyroid depth below the surface , thyroid shape and detector position . It is estimated that the uncertainty of the activity determination can reach several hundred percents . A mewed for absolute determination of the activity of a '251 source based on the counting rate values of file 27 keV photons and the 54 keV coincidence photo peak, which diminishes the geometry dependence of the counting efficiency , was applied to determine the uptake of 125-I in human thyroid In this work we checked also the application of the absolute determination method wife high sensitivity phoswich detectors. We compare the results of calculations of interval exposure to 125-I for a real case, evaluated by the absolute determination method and by the direct method. (authors)

  10. 242Pu absolute neutron-capture cross section measurement

    Science.gov (United States)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.

    2017-09-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ) cross section could be set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ) cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ) En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ) cross section.

  11. 242Pu absolute neutron-capture cross section measurement

    Directory of Open Access Journals (Sweden)

    Buckner M.Q.

    2017-01-01

    Full Text Available The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ cross section could be set according to the known 239Pu(n,f resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ cross section.

  12. Conversion frequence

    International Nuclear Information System (INIS)

    Sauteret, C.

    1987-03-01

    The experimental evidence of short wavelength for laser inertial confinement has strongly increased the interest in high efficiency harmonic conversion of powerful Nd: glass lasers. This work describes our high power harmonic conversion experiments performed using the same laser apparatus for doubling, tripling the three high power 1064 nm P102, OCTAL and PHEBUS lasers. In addition to the understanding the physics of harmonic conversion, this work includes the basic concepts allows us to improve the technique such as non colinear schemes, to extend this method to other frequencies (fourth generation) and to predict some physical limits [fr

  13. Frequency ratio of two optical clock transitions in 171Yb+ and constraints on the time variation of fundamental constants.

    Science.gov (United States)

    Godun, R M; Nisbet-Jones, P B R; Jones, J M; King, S A; Johnson, L A M; Margolis, H S; Szymaniec, K; Lea, S N; Bongs, K; Gill, P

    2014-11-21

    Singly ionized ytterbium, with ultranarrow optical clock transitions at 467 and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of 6×10(-16). Combining our results with those from other experiments, we report a threefold improvement in the constraint on the time variation of the proton-to-electron mass ratio, μ/μ=0.2(1.1)×10(-16)  yr(-1), along with an improved constraint on time variation of the fine structure constant, α/α=-0.7(2.1)×10(-17)  yr(-1).

  14. Reference Manual: Navy Message Words and Word Frequencies.

    Science.gov (United States)

    1981-12-29

    ALAMOS 26 ALAN I ALAPAYEVSKLES 2 ALARM I ALARMIST 5 It BACHENKO AND PARKER 2 ALASKA 1 ALASSIRI 2 ALB 1 ALBANOV 26 ALBANY 6 ALBERT 7 ALBORAN 2 ALCON I...HOE I HOFFERT 1 HOFFMAN 2 HOFFMEISTER 2 HOHSING 6 HOIST 6 HOISTING I HOKO 6 HOLA 9 HOLD I HOLDERS 26 HOLDING 2 HOLDS 6 HOLE 7 HOLIDAY 4 HOLIDAYS 2...15 LPLA I LPR 2 LR 8 LSD 2 LSE 1 LSM 55 LST I LSU 6 LT 2 LTAC I LTC 2 LTCDR 7 LTCOL 2 LTD 29 LTJG 3 LTN 56 LTR 9 LTRS 3 LU 2 LUALLIN 7 LUANDA 1 LUBE

  15. Absolute determination of deuterium content of heavy water standards by distillation and mass spectrometry

    International Nuclear Information System (INIS)

    Thurston, W.M.; James, M.W.D.

    1984-01-01

    An absolute method for heavy water standardization is described which is based on linear extrapolation to 100% D 2 O. The method uses a reflux column attached to a boiler containing the sample to be standardized. With the column operating at equilibrium under total reflux, samples from both the top and bottom of the column are converted to hydrogen and mass analyzed by use of an arbitrary D 2 O scale. To minimize mass spectrometer errors, the difference between top and bottom HD/total ion current is measured at the sample concentration and at several other slightly higher HD concentrations. The difference values vary linearly with the HDO concentration in the boiler. The linear relationship is extrapolated to zero HD difference as would be observed if 100% D 2 O were used. The extrapolated value on the arbitrary D 2 O scale is compared with 100% and any discrepancy represents an adjustment required to establish an absolute scale. The method has been tested at both the D 2 O and H 2 O ends of the range and has shown that the accuracy of the method is within the precision of 0.0006 mass % D 2 O. 8 references, 6 figures, 2 tables

  16. Repeated absolute gravity measurements for monitoring slow intraplate vertical deformation in Western Europe

    Science.gov (United States)

    Van Camp, M. J.; de Viron, O.; Scherneck, H.; Hinzen, K. G.; Williams, S. D.; Lecocq, T.; Quinif, Y.; Camelbeeck, T.

    2011-12-01

    In continental plate interiors, ground surface movements are at the limit of the noise level and close to or below the accuracy of current geodetic techniques. Absolute gravity measurements are valuable to quantify slow vertical movements, as this instrument is drift free and, unlike GPS, independent of the terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformation in the area. The AG measurements, repeated once or twice a year, can resolve elusive gravity changes with a precision better than 3.7 nm/s2/yr (95% confidence interval) after 11 years, even in difficult conditions. After 8-15 years (depending on the station), we find that the gravity rates of change lie in the [-3.1, 8.1] nm/s2/yr interval and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. After correcting for the GIA, the inferred gravity rates and consequently, the vertical land movements, reduce to zero within the uncertainty level at all stations except Jülich (due to man-induced subsidence) and Sohier (possibly, an artefact due to the shortness of the time series at that station).

  17. Tectonic, Climatic and Anthropogenic Vertical Land Movements in Western Europe by Repeated Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M. J.; de Viron, O.; Lecocq, T.; Hinzen, K. G.; Quinif, Y.; Williams, S. D.; Camelbeeck, T.

    2010-12-01

    In continental plate interiors, tectonic deformations are small and the associated ground surface movements remain close to or below the accuracy of current geodetic techniques, and at the limit of the noise level. An absolute gravimeter is an appropriate tool to quantify slow vertical movements, as this instrument, based on length and time standards, is drift free and does not depend on any terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformations in the area. After 7-13 years (depending on the station), we find evidence that the movements are no larger than a few millimeter per year and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. This demonstrates the importance of precisely modeling the GIA effects in order to investigate intraplate tectonic deformations at the sub-millimeter level. This study also shows that AG measurements, repeated once or twice a year, can resolve vertical velocities at the 1.0 mm/yr level after 10 years, even in difficult conditions, provided that the gravimeter is carefully maintained.

  18. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  19. Guide to listing references.

    Science.gov (United States)

    2005-01-01

    The introduction of listing references. It introduces the reference of printed sources, CD-ROMs, websites, unpublished papers and program manuals, tapes, or other documentation for models. Meanwhile, it describes some examples to use Chicago Manual o...

  20. CMS Statistics Reference Booklet

    Data.gov (United States)

    U.S. Department of Health & Human Services — The annual CMS Statistics reference booklet provides a quick reference for summary information about health expenditures and the Medicare and Medicaid health...

  1. VBE reference framework

    NARCIS (Netherlands)

    Afsarmanesh, H.; Camarinha-Matos, L.M.; Ermilova, E.; Camarinha-Matos, L.M.; Afsarmanesh, H.; Ollus, M.

    2008-01-01

    Defining a comprehensive and generic "reference framework" for Virtual organizations Breeding Environments (VBEs), addressing all their features and characteristics, is challenging. While the definition and modeling of VBEs has become more formalized during the last five years, "reference models"

  2. Frequência etiológica da hipertensão pulmonar em ambulatório de referência na Bahia Frecuencia etiológica de la hipertensión pulmonar en un ambulatorio de referencia en Bahia Etiological frequency of pulmonary hypertension in a reference outpatient clinic in Bahia, Brazil

    Directory of Open Access Journals (Sweden)

    Cesar Machado

    2009-12-01

    etiologies, with possible geographic influences; however, few studies have described the etiological frequency of PH, especially in our country. It is not clear whether there is an association between etiology and pulmonary pressure level or symptom intensity. OBJECTIVES: 1 to describe the etiological prevalence of PH in the state of Bahia, Brazil; 2 to evaluate whether the etiology is a determinant factor for the pulmonary pressure level; 3 to evaluate whether the etiology is a determinant factor for functional class; 4 to identify the other predictors of pulmonary pressure level and functional class. METHODS: The present was an observational, cross-sectional study that analyzed individuals with PH treated at the Magalhaes Neto Outpatient Clinic, between June 2005 and December 2007. PH was defined as pulmonary artery systolic pressure (PASP > 40 mmHg measure at the echocardiogram. Patients with chronic obstructive pulmonary disease or ventricular disease were excluded from the study. RESULTS: A total of 48 patients with PASP = 86 ± 24 mmHg were studied. Regarding the etiology, 42% of the patients were classified as idiopathic, followed by 25% as schistosomatic, 19% as congenital cardiopathy and 10% of chronic pulmonary embolism. A longer time of disease predicted higher pressures in patients with cardiopathy. Individuals with schistosomiasis had the best functional performance when compared to the others (456 ± 58 vs. 299 ± 138 meters, p=0.005. The schistosomatic etiology and younger age presented better functional class. CONCLUSIONS: 1 the idiopathic classification is the most prevalent, with schistosomiasis being the most frequent specific cause in our country; 2 patients with schistosomatic etiology and of younger age present better functional class. 3 the congenital cardiopathy results in a higher pressure level in the pulmonary artery, probably due to the longer duration of the disease.

  3. Absolute quantification of Bovine Viral Diarrhea Virus (BVDV) RNA by the digital PCR technique

    International Nuclear Information System (INIS)

    Flatschart, R B; Almeida, D O; Medeiros, M N; Granjeiro, J M; Folgueras-Flatschart, A V; Heinemann, M B

    2015-01-01

    The quality control of cell lines used in research and industry is critical to ensure confidence in experimental results and to guarantee the safety of biopharmaceuticals to consumers. The BVDV is a common adventitious agent in many cell lines. We preliminarly evaluate the use of Digital Droplet PCR (ddPCR) for the detection and enumeration of genome copies of BVDV in cell culture and on FBS. The application of a commercial Real-Time PCR kit with the ddPCR technique was successful on different matrices. The technique allowed the absolute quantification of the genome without the use of calibration standards, suggesting its promising application on the development of reference materials for quantification of nucleic acids

  4. Absolute quantification of Bovine Viral Diarrhea Virus (BVDV) RNA by the digital PCR technique

    Science.gov (United States)

    Flatschart, R. B.; Almeida, D. O.; Heinemann, M. B.; Medeiros, M. N.; Granjeiro, J. M.; Folgueras-Flatschart, A. V.

    2015-01-01

    The quality control of cell lines used in research and industry is critical to ensure confidence in experimental results and to guarantee the safety of biopharmaceuticals to consumers. The BVDV is a common adventitious agent in many cell lines. We preliminarly evaluate the use of Digital Droplet PCR (ddPCR) for the detection and enumeration of genome copies of BVDV in cell culture and on FBS. The application of a commercial Real-Time PCR kit with the ddPCR technique was successful on different matrices. The technique allowed the absolute quantification of the genome without the use of calibration standards, suggesting its promising application on the development of reference materials for quantification of nucleic acids.

  5. Absolute sensitivity of phase measurement in an SU(1,1) type interferometer

    Science.gov (United States)

    Du, Wei; Jia, Jun; Chen, J. F.; Ou, Z. Y.; Zhang, Weiping

    2018-03-01

    Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The interferometer is phase locked to a point with the largest quantum noise cancellation, and a simulated phase modulation is added in one arm of SU(1,1) interferometer. Both the signal and noise level are estimated at the same frequency range, and we obtain 3dB improvement in sensitivity for the SU(1,1) interferometer over the Mach-Zehnder interferometer. Our results demonstrate a direct phase estimation, and may pave the way for practical applications of nonlinear interferometer.

  6. Absolute sensitivity of phase measurement in an SU(1,1) type interferometer.

    Science.gov (United States)

    Du, Wei; Jia, Jun; Chen, J F; Ou, Z Y; Zhang, Weiping

    2018-03-01

    Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer, and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The interferometer is phase locked to a point with the largest quantum noise cancellation, and a simulated phase modulation is added in one arm of the SU(1,1) interferometer. Both the signal and noise level are estimated at the same frequency range, and we obtained 3 dB improvement in sensitivity for the SU(1,1) interferometer over the Mach-Zehnder interferometer. Our results demonstrate a direct phase estimation and may pave the way for practical applications of a nonlinear interferometer.

  7. EMISAR: An Absolutely Calibrated Polarimetric L- and C-band SAR

    DEFF Research Database (Denmark)

    Christensen, Erik Lintz; Skou, Niels; Dall, Jørgen

    1998-01-01

    and low cross-polar contamination. Digital technology has been utilized to realize a flexible and highly stable radar with variable resolution, swath width, and imaging geometry. Thermal control and several calibration loops have been built into the system to ensure system stability and absolute......EMISAR is a high-resolution (2×2 m), fully polarimetric, dual-frequency (L- and C-band) synthetic aperture radar (SAR) system designed for remote-sensing applications. The SAR is operated at high altitudes on a Gulfstream G-3 jet aircraft. The system is very well calibrated and has low sidelobes...... calibration. Accurately measured antenna gains and radiation patterns are included in the calibration. The processing system is developed to support data calibration, which is the key to most of the current applications. Recent interferometric enhancements are important for many scientific applications...

  8. The absolute radiometric calibration of the advanced very high resolution radiometer

    Science.gov (United States)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-01-01

    An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

  9. The absolute radiometric calibration of the advanced very high resolution radiometer

    Science.gov (United States)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-10-01

    An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

  10. Reference Management and Citation

    OpenAIRE

    Ebrahim, Nader Ale

    2014-01-01

    Reference Management system offers an easy way of collecting references from online databases, organizing them in a database, and citing them in documents in Microsoft Word. Documents can be shared with colleagues/publish online. A reference management system can facilitate the keeping track of the literature.

  11. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    Science.gov (United States)

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and

  12. Bridging the gap between perceptual and cognitive perspectives on absolute pitch.

    Science.gov (United States)

    Elmer, Stefan; Rogenmoser, Lars; Kühnis, Jürg; Jäncke, Lutz

    2015-01-07

    Absolute pitch (AP) refers to the rare ability to identify the chroma of a tone or to produce a specific pitch without reference to keyality (e.g., G or C). Previously, AP has been proposed to rely on the distinctive functional-anatomical architecture of the left auditory-related cortex (ARC), this specific trait possibly enabling an optimized early "categorical perception". In contrast, currently prevailing models of AP postulate that cognitive rather than perceptual processes, namely "pitch labeling" mechanisms, more likely constitute the bearing skeleton of AP. This associative memory component has previously been proposed to be dependent, among other mechanisms, on the recruitment of the left dorsolateral prefrontal cortex (DLPFC) as well as on the integrity of the left arcuate fasciculus, a fiber bundle linking the posterior supratemporal plane with the DLPFC. Here, we attempted to integrate these two apparently conflicting perspectives on AP, namely early "categorical perception" and "pitch labeling". We used electroencephalography and evaluated resting-state intracranial functional connectivity between the left ARC and DLPFC in a sample of musicians with and without AP. Results demonstrate significantly increased left-hemispheric theta phase synchronization in AP compared with non-AP musicians. Within the AP group, this specific electrophysiological marker was predictive of absolute-hearing behavior and explained ∼30% of variance. Thus, we propose that in AP subjects the tonal inputs and the corresponding mnemonic representations are tightly coupled in such a manner that the distinctive electrophysiological signature of AP can saliently be detected in only 3 min of resting-state measurements. Copyright © 2015 the authors 0270-6474/15/350366-06$15.00/0.

  13. Simple method for absolute calibration of geophones, seismometers, and other inertial vibration sensors

    International Nuclear Information System (INIS)

    Kann, Frank van; Winterflood, John

    2005-01-01

    A simple but powerful method is presented for calibrating geophones, seismometers, and other inertial vibration sensors, including passive accelerometers. The method requires no cumbersome or expensive fixtures such as shaker platforms and can be performed using a standard instrument commonly available in the field. An absolute calibration is obtained using the reciprocity property of the device, based on the standard mathematical model for such inertial sensors. It requires only simple electrical measurement of the impedance of the sensor as a function of frequency to determine the parameters of the model and hence the sensitivity function. The method is particularly convenient if one of these parameters, namely the suspended mass is known. In this case, no additional mechanical apparatus is required and only a single set of impedance measurements yields the desired calibration function. Moreover, this measurement can be made with the device in situ. However, the novel and most powerful aspect of the method is its ability to accurately determine the effective suspended mass. For this, the impedance measurement is made with the device hanging from a simple spring or flexible cord (depending on the orientation of its sensitive axis). To complete the calibration, the device is weighed to determine its total mass. All the required calibration parameters, including the suspended mass, are then determined from a least-squares fit to the impedance as a function of frequency. A demonstration using both a 4.5 Hz geophone and a 1 Hz seismometer shows that the method can yield accurate absolute calibrations with an error of 0.1% or better, assuming no a priori knowledge of any parameters

  14. Assessment of the Absolute Excitatory Level of the Retina by Flicker ERG.

    Science.gov (United States)

    Tanimoto, Naoyuki; Seeliger, Mathias W

    2018-01-01

    Electroretinography (ERG) is important for functional diagnostics of the retina. Types of information about retinal function obtainable by ERG differ depending on recording conditions, e.g., a combination of light stimulus and adaptation. In terms of stimulation, single-flash and flicker stimuli are frequently used because response properties have been well investigated, allowing an assessment of fundamental retinal functionality; for example, how photoreceptors and bipolar cells, including signal transmission between them, are affected under pathological conditions. Usually, ERGs are recorded with a nonzero lower cutoff frequency of amplifiers to avoid certain artifacts, and additionally, responses are averaged over time so that non-event-related signals are cancelled out. However, the improved signal quality is associated with a loss of information. Especially in steady-state flicker ERG, information about the absolute baseline of recordings is missing because the prestimulus baseline is not included on the recording trace as well as because a zero response is obtained in all cases in which the signal baseline stays constant for a sufficient amount of time. In other words, it is impossible to tell from the conventional flicker ERG whether a zero signal is obtained under conditions of maximal or no excitation of the visual system. In this chapter, we describe a direct current ERG protocol (featuring a lower cutoff frequency of zero) with repetitive single flashes mimicking conventional flicker that contains a defined onset. Using this recording protocol, it is possible to assess not only the absolute excitatory level of the retina but also the development of steady-state responses from the single flash response.

  15. Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

    Science.gov (United States)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2013-01-01

    A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

  16. Updated Absolute Age Estimates for the Tolstoj and Caloris Basins, Mercury

    Science.gov (United States)

    Ernst, C. M.; Denevi, B. W.; Ostrach, L. R.

    2016-12-01

    Time-stratigraphic systems are developed to provide a framework to derive the relative ages of terrains across a given planet, estimate their absolute ages, and aid cross-planet comparisons. Mercury's time-stratigraphic system was modeled after that of the Moon, with five systems defined on the basis of geologic mapping using Mariner 10 images. From oldest to youngest, Mercury's time-stratigraphic system contains the pre-Tolstojan, Tolstojan, Calorian, Mansurian, and Kuiperian systems. The formations of the Tolstoj and Caloris basins mark the start of the Tolstojan and Calorian systems, respectively. The Mansurian and Kuiperian systems are defined by the type craters for which they are named. The completion of MESSENGER's global image dataset marks an appropriate time to re-assess the time-stratigraphic system of the innermost planet. Recent work suggests the Mansurian and Kuiperian systems may have begun as recently as 1.7 Ga and 280 Ma, respectively (Banks et al., 2016). We used MESSENGER data to re-evaluate the relative and absolute ages of the Tolstoj and Caloris basins in to complete the reassessment of Mercury's time-stratigraphic system. We redefine basin rim units for Tolstoj and Caloris determine the crater size-frequency distribution for craters larger than 10 km in diameter. Two models for crater production are used to derive absolute ages from the crater counts: Marchi et al., 2009 (M) using a main belt asteroid-like impactor size-frequency distribution, hard rock crater scaling relations, target strength of 2e7 dyne/cm2, and target and projectile densities of 3.4 g/cm3 and 2.6 g/cm3; and Le Feuvre and Wieczorek 2011 (L&W) using non-porous scaling relations. We find N(20) values (the number of craters ≥ 20 km in diameter per million square km) for the Caloris rim of 37 ± 7 and for the Tolstoj rim of 93 ± 15. We derived model ages of 3.9 Ga (M) and 3.7 Ga (L&W) for Tolstoj and 3.7 Ga (M) and 3.1 Ga (L&W) for Caloris. Analysis to refine the ages using

  17. Automated absolute activation analysis with californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg /sup 252/Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from /sup 17/O. Detection sensitivities of < or = 400 ppB for natural uranium and 8 ppB (< or = 0.5 (nCi/g)) for /sup 239/Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level.

  18. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  19. Absolute dating methods for the Southern African Cainozoic

    Energy Technology Data Exchange (ETDEWEB)

    Patridge, T.C. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Anatomy); Netterburg, F. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Inst. for Transport and Road Research); Vogel, J.C. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Physical Research Lab.); Sellschop, J.P.F. (University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit)

    1984-09-01

    Those absolute dating methods other than radiocarbon which appear most useful for the Southern African Cainozoic are uranium disequilibrium, amino acid racemization, thermoluminescence, electron spin resonance, potassium/argon, and accelerator mass spectrometry. Although they are comparative dating methods only, the palaeo- and archaeomagnetic techniques appear most promising. More than one method is necessary to cover the ages and types of Southern African materials. The need for local dating services justifies the establishment of further Cainozoic dating facilities in South Africa. The necessary equipment is already available, or could be developed by adapting existing apparatus, so that only additional staff and funding would be required.

  20. Absolute nondestructive quantitative determination of uranium in special nuclear materials

    International Nuclear Information System (INIS)

    Dragnev, T.; Damyanov, B.; Grozev, G.; Karamanova, J.

    1985-01-01

    An absolute nondestructive method for quantitative measurement of uranium concentration and enrichment in special nuclear materials is proposed. The method uses intrinsic calibration and portable instrumentation and the particularly suitable for IAEA safequards applications. The intrinsic calibration accumulates the positive experience of the previous measurements and the results will be continuously improving. It is possible to measure standards in laboratories and use the results for analysis at different time and places. The tests show a good agreement with known classical methods and better results in some cases

  1. The absolute energy flux envelopes of B type stars.

    Science.gov (United States)

    Underhill, A. B.

    1972-01-01

    Absolute energy flux envelopes covering the region of 1100 to 6000 A for main-sequence stars of types B3, B7 and A0 derived from published, ground-based observations and from spectrum scans with OAO-II are presented. These flux envelopes are compared with the predicted flux envelopes from lightly line-blanketed model atmospheres. The line blanketing at wavelengths shorter than 3000 A is severe, about one-half the predicted light being observed at 1600 A. These results demonstrate that a model which represents well the observed visible spectrum of a star may fail seriously for representing the ultraviolet spectrum.

  2. Absolute gravimetry on the agulhas negras calibration line

    OpenAIRE

    Sousa, Mauro Andrade de; Santos, Alcides Antonio dos

    2010-01-01

    The Agulhas Negras Gravity Calibration Line was established in the mid 1980s using LaCoste & Romberg gravimeters model "G" only. Five gravity stations were irregularly positioned along its 200 km length, spanning a total range of 627 mGal. The new absolute gravimeter Micro-g Solutions A-10 #011 of Observatório Nacional was taken to each calibration station and new measurements were made. The local vertical gravity gradient was also measured at each calibration station. This report shows their...

  3. Absolute Mass Scale Calibration Using Z->mumu

    CERN Document Server

    Aleksa, Martin

    1999-01-01

    Detailed simulations have been performed, investigating the possibility of calibrating the absolute mass scale of the muon spectrometer by using Z->mumu A sample of 10000 events was processed through DICE/ATRECON applying different scale factors to the magnetic field as a function of phi and eta. It is shown that these scale factors could be retrieved with high accuracy together with the muon energy loss as a function of eta. It is shown that the energy loss in the barrel region could be found with an accuracy of 45 MeV while calibrating at the same time 2 magnetic field scale factors with an accuracy of 0.001.

  4. Quantum bath refrigeration towards absolute zero: challenging the unattainability principle.

    Science.gov (United States)

    Kolář, M; Gelbwaser-Klimovsky, D; Alicki, R; Kurizki, G

    2012-08-31

    A minimal model of a quantum refrigerator, i.e., a periodically phase-flipped two-level system permanently coupled to a finite-capacity bath (cold bath) and an infinite heat dump (hot bath), is introduced and used to investigate the cooling of the cold bath towards absolute zero (T=0). Remarkably, the temperature scaling of the cold-bath cooling rate reveals that it does not vanish as T→0 for certain realistic quantized baths, e.g., phonons in strongly disordered media (fractons) or quantized spin waves in ferromagnets (magnons). This result challenges Nernst's third-law formulation known as the unattainability principle.

  5. Exponential bound in the quest for absolute zero

    Science.gov (United States)

    Stefanatos, Dionisis

    2017-10-01

    In most studies for the quantification of the third law of thermodynamics, the minimum temperature which can be achieved with a long but finite-time process scales as a negative power of the process duration. In this article, we use our recent complete solution for the optimal control problem of the quantum parametric oscillator to show that the minimum temperature which can be obtained in this system scales exponentially with the available time. The present work is expected to motivate further research in the active quest for absolute zero.

  6. An Algorithm for Solving the Absolute Value Equation

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří

    2009-01-01

    Roč. 18, - (2009), s. 589-599 E-ISSN 1081-3810 R&D Projects: GA ČR GA201/09/1957; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : absolute value equation * algorithm * regularity * singularity * theorem of the alternatives Subject RIV: BA - General Mathematics Impact factor: 0.892, year: 2009 http://www.math.technion.ac.il/iic/ ela / ela -articles/articles/vol18_pp589-599.pdf

  7. Absolute coverage of the saturated cesium silicon interfaces

    Science.gov (United States)

    Sherman, William Benjamin

    Metal/semiconductor interfaces are of great interest for a variety of reasons. They shed light on surface metal/semiconductor transitions, and they form Schottky barriers, which are of scientific as well as significant technological importance (primarily for the production of high speed, low-power logic circuitry). The cesium/silicon interfaces are of particular interest since the oxide forms a Negative Electron Affinity state. Cesium does not mix with the bulk silicon, so the interface is very abrupt, and the electronic structure of cesium is easier to understand than that of the transition metals. Further, cesium (like other alkali metals at room temperature) forms a single atomic layer on the various silicon faces and then the coverage saturates (i.e. atoms stop sticking to the surface). This makes the cesium/silicon interfaces ideal model systems of the metal/semiconductor interface. In spite of their importance, the detailed structures of the cesium saturated silicon faces are still uncertain. Numerous structural models have been proposed and many of them have quite different absolute coverages. Thus absolute coverage measurements can effectively distinguish between the various models. Rutherford Backscattering Spectrometry (RBS) provides an ideal measurement of absolute coverage since its results can be directly interpreted without dependence upon any structural model. A new beam line has been set up on the Laboratory for Research on the Structure of Matter's tandem accelerator. The Ultrahigh Vacuum system is equipped with an Auger Electron Spectrometer, a Low Energy Electron Diffraction system, a retarding field method work function analyzer, a cesium doser, a Medium Energy Ion Scattering two dimensional toroidal analyzer and a Rutherford Backscattering: Spectrometry (RBS) solid state ion detector. It has been used to manufacture saturated Cs/Si(100)-2 x 1 and Cs/Si(111)-7 x 7 interfaces and measure their absolute coverage via RBS. The coverage for the Si

  8. Optimal quantum error correcting codes from absolutely maximally entangled states

    Science.gov (United States)

    Raissi, Zahra; Gogolin, Christian; Riera, Arnau; Acín, Antonio

    2018-02-01

    Absolutely maximally entangled (AME) states are pure multi-partite generalizations of the bipartite maximally entangled states with the property that all reduced states of at most half the system size are in the maximally mixed state. AME states are of interest for multipartite teleportation and quantum secret sharing and have recently found new applications in the context of high-energy physics in toy models realizing the AdS/CFT-correspondence. We work out in detail the connection between AME states of minimal support and classical maximum distance separable (MDS) error correcting codes and, in particular, provide explicit closed form expressions for AME states of n parties with local dimension \

  9. Physics of Non-Inertial Reference Frames

    International Nuclear Information System (INIS)

    Kamalov, Timur F.

    2010-01-01

    Physics of non-inertial reference frames is a generalizing of Newton's laws to any reference frames. It is the system of general axioms for classical and quantum mechanics. The first, Kinematics Principle reads: the kinematic state of a body free of forces conserves and equal in absolute value to an invariant of the observer's reference frame. The second, Dynamics Principle extended Newton's second law to non-inertial reference frames and also contains additional variables there are higher derivatives of coordinates. Dynamics Principle reads: a force induces a change in the kinematic state of the body and is proportional to the rate of its change. It is mean that if the kinematic invariant of the reference frame is n-th derivative with respect the time, then the dynamics of a body being affected by the force F is described by the 2n-th differential equation. The third, Statics Principle reads: the sum of all forces acting a body at rest is equal to zero.

  10. A 'Global Reference' Comparator for Biosimilar Development.

    Science.gov (United States)

    Webster, Christopher J; Woollett, Gillian R

    2017-08-01

    Major drug regulators have indicated in guidance their flexibility to accept some development data for biosimilars generated with reference product versions licensed outside their own jurisdictions, but most authorities require new bridging studies between these versions and the versions of them licensed locally. The costs of these studies are not trivial in absolute terms and, due to the multiplier effect of required repetition by each biosimilar sponsor, their collective costs are substantial. Yet versions of biologics licensed in different jurisdictions usually share the same development data, and any manufacturing changes between versions have been justified by a rigorous comparability process. The fact that a biosimilar is usually expected to be licensed in multiple jurisdictions, in each case as similar to the local reference product, confirms that minor analytical differences between versions of reference biologics are typically inconsequential for clinical outcomes and licensing. A greatly simplified basis for selecting a reference comparator, that does not require conducting new bridging studies, is proposed and justified based on the shared data of the reference product versions as well as the proof offered where biosimilars have already been approved. The relevance of this proposal to the interchangeability designation available in the US is discussed.

  11. The instantaneous frequency rate spectrogram

    Science.gov (United States)

    Czarnecki, Krzysztof

    2016-01-01

    An accelerogram of the instantaneous phase of signal components referred to as an instantaneous frequency rate spectrogram (IFRS) is presented as a joint time-frequency distribution. The distribution is directly obtained by processing the short-time Fourier transform (STFT) locally. A novel approach to amplitude demodulation based upon the reassignment method is introduced as a useful by-product. Additionally, an estimator of energy density versus the instantaneous frequency rate (IFR) is proposed and referred to as the IFR profile. The energy density is estimated based upon both the classical energy spectrogram and the IFRS smoothened by the median filter. Moreover, the impact of an analyzing window width, additive white Gaussian noise and observation time is tested. Finally, the introduced method is used for the analysis of the acoustic emission of an automotive engine. The recording of the engine of a Lamborghini Gallardo is analyzed as an example.

  12. The Lean Reference Collection: Improving Functionality through Selection and Weeding.

    Science.gov (United States)

    Nolan, Christopher W.

    1991-01-01

    Discusses references collections in academic libraries and offers guidelines for placing materials in a reference collection that focus on their suitability for true reference functions and the expected frequency of use. Problems with poorly managed collections are discussed, and the importance of selection policies and weeding are emphasized. (37…

  13. Research on absolute measurement of 222Rn/220Rn concentrations based on a single small scintillation cell and delay-time method

    International Nuclear Information System (INIS)

    Zhou Jianbo; Zhao Xiuliang; Yu Hong; Xiao Yongjun; Wu Yongyan

    2009-01-01

    A single small scintillation with delay-time method is used to measure radon and thoron concentrations in their mixed atmosphere-of absolute measurement of radon and thoron concentrations was discussed. The conditions of using radon to test this method was described and a experiment was designed to prove it. Compare to the reference number, Its margin of error was -2.9%∼+3.4%, and the best time of the measurement of radon was 10-45 minutes. In conclusion, a single small scintillation cell could be used for absolute measurement radon and thoron concentrations. (authors)

  14. SI-traceable absolute distance measurement over more than 800 meters with sub-nanometer interferometry by two-color inline refractivity compensation

    Science.gov (United States)

    Meiners-Hagen, Karl; Meyer, Tobias; Mildner, Jutta; Pollinger, Florian

    2017-11-01

    In this work, we demonstrate two-color inline refractivity compensation in a heterodyne synthetic wavelength interferometer for a measurement of absolute distances over several hundred meters with sub-millimeter accuracy. Two frequency-doubled Nd:YAG lasers with a coherence length of more than 1 km are used as light sources. Direct SI traceability is achieved by controlling the lasers' frequency difference in the radio frequency regime. The resulting synthetic wavelengths at 532 nm and 1064 nm are used for the absolute distance measurement and dispersion-based inline refractive index compensation. A standard deviation of 50 μm is achieved for distances up to 864 m. This performance corresponds to a standard deviation of the observable, the difference of the four optical wavelengths, on a sub-nanometer level. Comparison against white light interferometry confirms sub-millimeter accuracy over this distance. Temporally resolved data over 864 m provide quantitative insights into the influence of chromatic beam paths.

  15. The Determination of Absolute Sea level Rise in New Zealand

    Science.gov (United States)

    Hannah, J.; Denys, P. H.; Beavan, R. J.

    2010-12-01

    Long term sea level trends at five New Zealand tide gauges with records > 60 yr in length have been determined through to the end of 2008. These gauges, with a wide spatial distribution, reveal an average relative sea level rise across of 1.7 ± 0.1 mm/yr. When a Glacial Isostatic adjustment (GIA) is applied using Peltier’s ICE 5G (v1.2) model, this estimated trend rises to 2.0 mm/yr. However, the absolute trends, when calculated using approximately 10 years of cGPS data at the four gauges with the longest records (Auckland, Wellington, Lyttelton and Dunedin), show a sea level rise of only 1.2 ± 0.4 mm/yr. If the Wellington gauge (located in the transitional plate boundary zone) is removed, this absolute trend rises to 1.4 mm/yr. This paper outlines how the above results were obtained and discusses proposed future research directions. It also includes previously unpublished data on relative sea level trends as determined at a further four New Zealand tide gauge sites.

  16. PROFIT AND LOSS ACCOUNT – SYNTHETIC EXPRESSION OF ABSOLUTE RETURN

    Directory of Open Access Journals (Sweden)

    MIRON VASILE CRISTIAN IOACHIM

    2017-08-01

    Full Text Available This study has as main objective the presentation of the current state of knowledge regarding the profit and loss account as part of the financial statements which express in absolute value the profitability of companies and the empirical analysis of these concepts based on the information submitted by OMV Petrom between 2011 and 2015. Thus, in the first part we present several approaches from the specialized literature regarding the aspects mentioned above. The second part follows a vertical and horizontal analysis of key indicators used for measuring the absolute return. For the horizontal analysis we pursued the evolution in time of the following indicators: Gross Margin, Earnings Before Interest and Taxes (EBIT, Financial Result, Gross and Net Result. The vertical analysis aimed to explain the formation of the Gross Result via EBIT (which was also analyzed through the Gross Margin and other specific elements and of the Financial Result (which was also analyzed through the different types of financial income and expenses. The results of the study revealed problems of profitability in the years 2014 and 2015 which, in our opinion, can be attributed to poor management of the commercial activity, exploration activity (research and development, distribution and financial activity.

  17. Use of intensity quotients and differences in absolute structure refinement

    Science.gov (United States)

    Parsons, Simon; Flack, Howard D.; Wagner, Trixie

    2013-01-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  18. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    International Nuclear Information System (INIS)

    Hernández, E.M.; Juárez, A.M.; Kilcoyne, A.L.D.; Aguilar, A.; Hernández, L.; Antillón, A.; Macaluso, D.; Morales-Mori, A.; González-Magaña, O.; Hanstorp, D.; Covington, A.M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    2015-01-01

    The photoionization of Cl + leading to Cl 2+ was measured in the photon energy range of 19.5–28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl + ion beam with a photon beam of highly monochromatic synchrotron radiation at the Advanced Light Source at Lawrence Berkeley National Laboratory. The measured photoionization of Cl + consists of several autoionization resonances surperimposed on the direct photoionization signal. Most of the prominent resonances are assigned to members of Rydberg series originating from the singlet ground state and from metastable triplet levels within the ground-state configuration of Cl + . The direct ionization cross section is no larger than 12 Mb. - Highlights: • The single photoionization absolute cross section of Cl + ion was measured. • Numerous resonances were identified as belonging to Rydberg series. • A large population of the metastable Cl + ( 1 D 2 ) was identified. • Identified resulting Cl 2+ state terms correspond to 2 D 5/2 and 2 D 3/2

  19. Absolute values of neutrino masses: status and prospects

    International Nuclear Information System (INIS)

    Bilenky, S.M.; Giunti, C.; Grifols, J.A.; Masso, E.

    2003-01-01

    Compelling evidences in favor of neutrino masses and mixing obtained in the last years in Super-Kamiokande, SNO, KamLAND and other neutrino experiments made the physics of massive and mixed neutrinos a frontier field of research in particle physics and astrophysics. There are many open problems in this new field. In this review we consider the problem of the absolute values of neutrino masses, which apparently is the most difficult one from the experimental point of view. We discuss the present limits and the future prospects of β-decay neutrino mass measurements and neutrinoless double-β decay. We consider the important problem of the calculation of nuclear matrix elements of neutrinoless double-β decay and discuss the possibility to check the results of different model calculations of the nuclear matrix elements through their comparison with the experimental data. We discuss the upper bound of the total mass of neutrinos that was obtained recently from the data of the 2dF Galaxy Redshift Survey and other cosmological data and we discuss future prospects of the cosmological measurements of the total mass of neutrinos. We discuss also the possibility to obtain information on neutrino masses from the observation of the ultra high-energy cosmic rays (beyond the GZK cutoff). Finally, we review the main aspects of the physics of core-collapse supernovae, the limits on the absolute values of neutrino masses from the observation of SN1987A neutrinos and the future prospects of supernova neutrino detection

  20. Android quick APIs reference

    CERN Document Server

    Cinar, Onur

    2015-01-01

    The Android Quick APIs Reference is a condensed code and APIs reference for the new Google Android 5.0 SDK. It presents the essential Android APIs in a well-organized format that can be used as a handy reference. You won't find any technical jargon, bloated samples, drawn out history lessons, or witty stories in this book. What you will find is a software development kit and APIs reference that is concise, to the point and highly accessible. The book is packed with useful information and is a must-have for any mobile or Android app developer or programmer. In the Android Quick APIs Refe

  1. What refers? How?

    OpenAIRE

    Barber, Alexander

    2011-01-01

    “Guns don’t kill people, people kill people.” This National Rifle Association slogan has a popular analogue in the philosophy of language: words don’t refer to things, people refer to things. This paper looks at how the question of what refers (Words/concepts? People? Both? Neither?) intersects with the phenomenon of opacity. The discussion is used to motivate an important revision to standard intention-based accounts of speaker reference, one that takes due account of the fact that distinct ...

  2. Improved Strategies and Optimization of Calibration Models for Real-time PCR Absolute Quantification

    Science.gov (United States)

    Real-time PCR absolute quantification applications rely on the use of standard curves to make estimates of DNA target concentrations in unknown samples. Traditional absolute quantification approaches dictate that a standard curve must accompany each experimental run. However, t...

  3. Regional absolute conductivity reconstruction using projected current density in MREIT

    International Nuclear Information System (INIS)

    Sajib, Saurav Z K; Kim, Hyung Joong; Woo, Eung Je; Kwon, Oh In

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a non-invasive technique for imaging the internal conductivity distribution in tissue within an MRI scanner, utilizing the magnetic flux density, which is introduced when a current is injected into the tissue from external electrodes. This magnetic flux alters the MRI signal, so that appropriate reconstruction can provide a map of the additional z-component of the magnetic field (B z ) as well as the internal current density distribution that created it. To extract the internal electrical properties of the subject, including the conductivity and/or the current density distribution, MREIT techniques use the relationship between the external injection current and the z-component of the magnetic flux density B = (B x , B y , B z ). The tissue studied typically contains defective regions, regions with a low MRI signal and/or low MRI signal-to-noise-ratio, due to the low density of nuclear magnetic resonance spins, short T 2 or T* 2 relaxation times, as well as regions with very low electrical conductivity, through which very little current traverses. These defective regions provide noisy B z data, which can severely degrade the overall reconstructed conductivity distribution. Injecting two independent currents through surface electrodes, this paper proposes a new direct method to reconstruct a regional absolute isotropic conductivity distribution in a region of interest (ROI) while avoiding the defective regions. First, the proposed method reconstructs the contrast of conductivity using the transversal J-substitution algorithm, which blocks the propagation of severe accumulated noise from the defective region to the ROI. Second, the proposed method reconstructs the regional projected current density using the relationships between the internal current density, which stems from a current injection on the surface, and the measured B z data. Combining the contrast conductivity distribution in the entire imaging

  4. Direct and Absolute Quantification of over 1800 Yeast Proteins via Selected Reaction Monitoring.

    Science.gov (United States)

    Lawless, Craig; Holman, Stephen W; Brownridge, Philip; Lanthaler, Karin; Harman, Victoria M; Watkins, Rachel; Hammond, Dean E; Miller, Rebecca L; Sims, Paul F G; Grant, Christopher M; Eyers, Claire E; Beynon, Robert J; Hubbard, Simon J

    2016-04-01

    Defining intracellular protein concentration is critical in molecular systems biology. Although strategies for determining relative protein changes are available, defining robust absolute values in copies per cell has proven significantly more challenging. Here we present a reference data set quantifying over 1800Saccharomyces cerevisiaeproteins by direct means using protein-specific stable-isotope labeled internal standards and selected reaction monitoring (SRM) mass spectrometry, far exceeding any previous study. This was achieved by careful design of over 100 QconCAT recombinant proteins as standards, defining 1167 proteins in terms of copies per cell and upper limits on a further 668, with robust CVs routinely less than 20%. The selected reaction monitoring-derived proteome is compared with existing quantitative data sets, highlighting the disparities between methodologies. Coupled with a quantification of the transcriptome by RNA-seq taken from the same cells, these data support revised estimates of several fundamental molecular parameters: a total protein count of ∼100 million molecules-per-cell, a median of ∼1000 proteins-per-transcript, and a linear model of protein translation explaining 70% of the variance in translation rate. This work contributes a "gold-standard" reference yeast proteome (including 532 values based on high quality, dual peptide quantification) that can be widely used in systems models and for other comparative studies. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  5. Direct and Absolute Quantification of over 1800 Yeast Proteins via Selected Reaction Monitoring*

    Science.gov (United States)

    Lawless, Craig; Holman, Stephen W.; Brownridge, Philip; Lanthaler, Karin; Harman, Victoria M.; Watkins, Rachel; Hammond, Dean E.; Miller, Rebecca L.; Sims, Paul F. G.; Grant, Christopher M.; Eyers, Claire E.; Beynon, Robert J.

    2016-01-01

    Defining intracellular protein concentration is critical in molecular systems biology. Although strategies for determining relative protein changes are available, defining robust absolute values in copies per cell has proven significantly more challenging. Here we present a reference data set quantifying over 1800 Saccharomyces cerevisiae proteins by direct means using protein-specific stable-isotope labeled internal standards and selected reaction monitoring (SRM) mass spectrometry, far exceeding any previous study. This was achieved by careful design of over 100 QconCAT recombinant proteins as standards, defining 1167 proteins in terms of copies per cell and upper limits on a further 668, with robust CVs routinely less than 20%. The selected reaction monitoring-derived proteome is compared with existing quantitative data sets, highlighting the disparities between methodologies. Coupled with a quantification of the transcriptome by RNA-seq taken from the same cells, these data support revised estimates of several fundamental molecular parameters: a total protein count of ∼100 million molecules-per-cell, a median of ∼1000 proteins-per-transcript, and a linear model of protein translation explaining 70% of the variance in translation rate. This work contributes a “gold-standard” reference yeast proteome (including 532 values based on high quality, dual peptide quantification) that can be widely used in systems models and for other comparative studies. PMID:26750110

  6. Effects of Warmness and Spatial Nonuniformity of the Plasma Waveguide on Periodic Absolute Parametric Instability

    International Nuclear Information System (INIS)

    Zaki, N.G.; Bekheit, A.H.

    2011-01-01

    The periodic absolute parametric instability (API) of the low-frequency oscillations excited by a monochromatic pumping field of arbitrary amplitude in a warm I-D nonuniform magneto active plasma is investigated. One can use the separation method to solve the two-fluid plasma equations which describe the system. The method used enables us to determine the frequencies and growth rates of unstable modes and the self-consistent electric field. Plasma electrons are considered to have a thermal velocity. One can examine different solutions for the spatial equation in the following cases: A) API in uniform Plasma B) API in nonuniform plasma, we study this case for two variants: B.1) Exact harmonic oscillator and B.2) Bounded harmonic oscillator (bounded plasma). Increment is found in the buildup of the oscillations, and it is shown that the spatial nonuniformity of the plasma exerts a stabilizing effect on the parametric instability. It is shown that the growth rate of API in warm plasma is reduced compared to cold plasma. It is found also that the warmness of the plasma has no effect on the solution of the space part of the problem ( only through the separation constant )

  7. Marketing Reference Services.

    Science.gov (United States)

    Norman, O. Gene

    1995-01-01

    Relates the marketing concept to library reference services. Highlights include a review of the literature and an overview of marketing, including research, the marketing mix, strategic plan, marketing plan, and marketing audit. Marketing principles are applied to reference services through the marketing mix elements of product, price, place, and…

  8. The Reference Return Ratio

    DEFF Research Database (Denmark)

    Nicolaisen, Jeppe; Faber Frandsen, Tove

    2008-01-01

    The paper introduces a new journal impact measure called The Reference Return Ratio (3R). Unlike the traditional Journal Impact Factor (JIF), which is based on calculations of publications and citations, the new measure is based on calculations of bibliographic investments (references) and returns...

  9. Geographies of High Frequency Trading

    DEFF Research Database (Denmark)

    Grindsted, Thomas Skou

    2016-01-01

    This paper investigates the geographies of high frequency trading. Today shares shift hands within micro seconds, giving rise to a form of financial geographies termed algorithmic capitalism. This notion refers to the different spatio-temporalities produced by high frequency trading, under...... the valuation of time. As high frequency trading accelerates financial markets, the paper examines the spatio-temporalities of automated trading by the ways in which the speed of knowledge exploitation in financial markets is not only of interest, but also the expansion between different temporalities....... The paper demonstrates how the intensification of time-space compression produces radical new dynamics in the financial market and develops information rent in HFT as convertible to a time rent and a spatio-temporal rent. The final section discusses whether high frequency trading only responds to crises...

  10. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis.

    Science.gov (United States)

    Yuan, H S; Stevens, R C; Bau, R; Mosher, H S; Koetzle, T F

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanal-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH3)3 group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH3)3 groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2(1) (monoclinic), a = 18.564(6) A, b = 7.713(2) A, c = 23.361(8) A, beta = 94.18(4) degrees, V = 3336.0(5) A3, Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis).

  11. On Frequency Combs in Monolithic Resonators

    Directory of Open Access Journals (Sweden)

    Savchenkov A. A.

    2016-06-01

    Full Text Available Optical frequency combs have become indispensable in astronomical measurements, biological fingerprinting, optical metrology, and radio frequency photonic signal generation. Recently demonstrated microring resonator-based Kerr frequency combs point the way towards chip scale optical frequency comb generator retaining major properties of the lab scale devices. This technique is promising for integrated miniature radiofrequency and microwave sources, atomic clocks, optical references and femtosecond pulse generators. Here we present Kerr frequency comb development in a historical perspective emphasizing its similarities and differences with other physical phenomena. We elucidate fundamental principles and describe practical implementations of Kerr comb oscillators, highlighting associated solved and unsolved problems.

  12. Absolute Astrometry in the next 50 Years - II

    Science.gov (United States)

    Høg, E.

    2018-01-01

    With the Gaia astrometric satellite in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A space mission with Gaia-like astrometric performance is required, but not necessarily a Gaia-like satellite. A dozen science issues for a Gaia successor mission in twenty years, with launch about 2035, are presented and in this context also other possibilities for absolute astrometry with milliarcsecond (mas) or sub-mas accuracies are discussed in my report at http://arxiv.org/abs/1408.2190. In brief, the two missions (2013 and 2035) would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems, including exo-planet systems with long periods, to compact galaxies, quasars and Dark Matter substructures by data which cannot be surpassed in the next 50 years.

  13. Absolute configuration of cembrane diterpenoids from Bursera multijuga.

    Science.gov (United States)

    Hernández-Hernández, Juan D; García-Gutiérrez, Hugo A; Román-Marín, Luisa U; Torres-Blanco, Yunuen I; Cerda-García-Rojas, Carlos M; Joseph-Nathan, Pedro

    2014-09-01

    The stems of Bursera multijuga afforded (-)-(1S,3E,7R,8R,11E)-7,8-epoxycembra-3,11-dien-1-ol (1) and its acetate 2, together with cembrene A (3), nephthenol (4), and cembrenol (5). The structures of 1 and 2 were elucidated by 1D and 2D NMR, HRESIMS, and X-ray diffraction. The conformational preference of flexible 1 was studied by molecular modeling at the DFT B3LYP/DGDZVP level of theory. Good agreement between calculated and experimental vibrational circular dichroism curves established the absolute configuration of 1. This is the first time that cembrane derivatives have been isolated from the genus Bursera.

  14. Ensuring long-term stability of infrared camera absolute calibration.

    Science.gov (United States)

    Kattnig, Alain; Thetas, Sophie; Primot, Jérôme

    2015-07-13

    Absolute calibration of cryogenic 3-5 µm and 8-10 µm infrared cameras is notoriously instable and thus has to be repeated before actual measurements. Moreover, the signal to noise ratio of the imagery is lowered, decreasing its quality. These performances degradations strongly lessen the suitability of Infrared Imaging. These defaults are often blamed on detectors reaching a different "response state" after each return to cryogenic conditions, while accounting for the detrimental effects of imperfect stray light management. We show here that detectors are not to be blamed and that the culprit can also dwell in proximity electronics. We identify an unexpected source of instability in the initial voltage of the integrating capacity of detectors. Then we show that this parameter can be easily measured and taken into account. This way we demonstrate that a one month old calibration of a 3-5 µm camera has retained its validity.

  15. Absolute dimensions and evolutionary status of UW CMa

    International Nuclear Information System (INIS)

    Parthasarathy, M.

    1978-01-01

    Photoelectric B and V light curves of close binary system UW Canis Majoris (08.5 If + O-B) are analysed. Combining the photoelectric elements and the spectroscopic orbit absolute dimensions of the system are determined. The mass of the bright primary (08.5 If) component is found to be 19.3 solar masses and that of the faint secondary to be 23.2 solar masses. The primary has filled the Roche lobe and it is 1 to 2 mag over-luminous for its mass. The massive secondary component is most likely a main sequence star. Comparison with the theoretical evolutionary models of massive close binary systems undergoing case A of mass exchange indicate that UW CMa is close to the contact stage of evolution. (author)

  16. Measured and modelled absolute gravity changes in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil; Forsberg, René; Strykowski, Gabriel

    2014-01-01

    In glaciated areas, the Earth is responding to the ongoing changes of the ice sheets, a response knownas glacial isostatic adjustment (GIA). GIA can be investigated through observations of gravity change.For the ongoing assessment of the ice sheets mass balance, where satellite data are used...... in Greenland. Theresult is compared with the initial measurements of absolute gravity (AG) change at selected GreenlandNetwork (GNET) sites.We find that observations are highly influenced by the direct attraction from the ice and ocean. Thisis especially evident in the measurements conducted at the GNET...... station near the Helheim Glacier.The effect of the direct attraction diminishes at sites that are more than one degree from the source.Here, the dominant signal is the effect of the elastic signal from present day ice mass changes. We findagreement between the measured and modelled gravity changes at all...

  17. Measured and modelled absolute gravity changes in Greenland

    Science.gov (United States)

    Nielsen, J. Emil; Forsberg, Rene; Strykowski, Gabriel

    2014-01-01

    In glaciated areas, the Earth is responding to the ongoing changes of the ice sheets, a response known as glacial isostatic adjustment (GIA). GIA can be investigated through observations of gravity change. For the ongoing assessment of the ice sheets mass balance, where satellite data are used, the study of GIA is important since it acts as an error source. GIA consists of three signals as seen by a gravimeter on the surface of the Earth. These signals are investigated in this study. The ICE-5G ice history and recently developed ice models of present day changes are used to model the gravity change in Greenland. The result is compared with the initial measurements of absolute gravity (AG) change at selected Greenland Network (GNET) sites.

  18. Absolute distance measurement by two-point-diffraction interferometry

    International Nuclear Information System (INIS)

    Rhee, Hyug-Gyo; Kim, Seung-Woo

    2002-01-01

    We present a point-diffraction interferometer that has been specially devised to perform absolute distance measurements in three dimensions. It is composed of two main parts: One is a target that moves in three dimensions, and the other is a stationary two-dimensional array of photodetectors. The target is made of point-diffraction sources that emit two spherical wave fronts, whose interference is monitored by the photodetectors. Application of a phase-shifting technique allows the phase values of the photodetectors to be precisely measured, which are then fitted to a geometric model of multilateration so as to determine the xyz location of the target by minimization of least-squares errors. Experimental results show that the proposed diffraction interferometer is capable of measuring the xyz coordinates of the target with a volumetric uncertainty of less than 1.0 μm over a working volume of a 100-mm side

  19. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    Science.gov (United States)

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  20. Absolute Measurement of Tilts via Fourier Analysis of Interferograms

    Science.gov (United States)

    Toland, Ronald W.

    2004-01-01

    The Fourier method of interferogram analysis requires the introduction of a constant tilt into the interferogram to serve as a carrier signal for information on the figure of the surface under test. This tilt is usually removed in the first steps of analysis and ignored thereafter. However, in the problem of aligning optical components and systems, knowledge of part orientation is crucial to proper instrument performance. This paper outlines an algorithm which uses the normally ignored carrier signal in Fourier analysis to compute an absolute tilt (orientation) of the test surface. We also provide a brief outline of how this technique, incorporated in a rotating Twyman-Green interferometer, can be used in alignment and metrology of optical systems.

  1. The neurocognitive components of pitch processing: insights from absolute pitch.

    Science.gov (United States)

    Wilson, Sarah J; Lusher, Dean; Wan, Catherine Y; Dudgeon, Paul; Reutens, David C

    2009-03-01

    The natural variability of pitch naming ability in the population (known as absolute pitch or AP) provides an ideal method for investigating individual differences in pitch processing and auditory knowledge formation and representation. We have demonstrated the involvement of different cognitive processes in AP ability that reflects varying skill expertise in the presence of similar early age of onset of music tuition. These processes were related to different regions of brain activity, including those involved in pitch working memory (right prefrontal cortex) and the long-term representation of pitch (superior temporal gyrus). They reflected expertise through the use of context dependent pitch cues and the level of automaticity of pitch naming. They impart functional significance to structural asymmetry differences in the planum temporale of musicians and establish a neurobiological basis for an AP template. More generally, they indicate variability of knowledge representation in the presence of environmental fostering of early cognitive development that translates to differences in cognitive ability.

  2. Development of the absolute standardization apparatus for radon-222 activity.

    Science.gov (United States)

    Liang, Juncheng; Yang, Zhijie; Wang, Liyuan; Li, Zexi; Zhang, Ming; Liu, Haoran; Yuan, Daqing

    2018-04-01

    A defined solid angle counting apparatus for radon-222 activity absolute measurement is presented. Two home-made vacuum sealed radium-226 sources with radioactivity of 500kBq and 3MBq are used to minimize the impact from gas impurities. The defined solid angle is calculated using precisely measured geometrical parameters by several algorithms. The result from Monte Carlo simulation agrees with results obtained by other methods within the estimated uncertainty limit. Alpha particle's scattering behavior in the measurement chamber and collimator is simulated by the geant4 code and a total scattering alpha particle ratio of 0.23% as well as a relative uncertainty contribution to activity measurement of 0.02% to 0.09% are estimated. A typical total combined standard uncertainty of 0.28% is evaluated for the radon activity primary measurement. Copyright © 2017. Published by Elsevier Ltd.

  3. Absolute luminosity measurement at LHCb with beam-gas imaging

    CERN Document Server

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam-Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used *van der Meer scan* method (VDM). The technique has been used in 10 LHC fills during 2012 including and also provided a first luminosity measurement for proton-lead collisions. This talk presents the principles of the gas injection and the improvements reached with the increased pressure. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch. Those uncertainties are becoming the dominating factor because the uncertainty on the total beam current have been reduced.

  4. Gravitational Acceleration as a Cue for Absolute Size and Distance

    Science.gov (United States)

    Hecht, Heiko; Kaiser, Mary K.; Banks, Martin S.; Hart, Sandra G. (Technical Monitor)

    1994-01-01

    When an object's motion is influenced by gravity, such as the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In three experiments, we examined the ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory parallel to the gravitational vector. The simulated objects were three balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify which ball was presented and the distance at which it was presented. The results of Experiment 1 showed that size and distance judgments were significantly better than chance, but not as accurate as expected if the information contained in the dynamics of free fall were used fully utilized. The results of Experiment 2 showed that acceleration information is used, but that observers can also make use of velocity information. Finally, the results of Experiment 3 showed that observers can use projected size information, but that their size and distance judgments are much more accurate when motion information is present as well. These results show that observers can use the information in the dynamics of free fall to estimate absolute size and distance, but their estimates are not as accurate as they could be if the information were used effectively.

  5. Cylindrical Taylor states conserving total absolute magnetic helicity

    Science.gov (United States)

    Low, B. C.; Fang, F.

    2014-09-01

    The Taylor state of a three-dimensional (3D) magnetic field in an upright cylindrical domain V is derived from first principles as an extremum of the total magnetic energy subject to a conserved, total absolute helicity Habs. This new helicity [Low, Phys. Plasmas 18, 052901 (2011)] is distinct from the well known classical total helicity and relative total helicity in common use to describe wholly-contained and anchored fields, respectively. A given field B, tangential along the cylindrical side of V, may be represented as a unique linear superposition of two flux systems, an axially extended system along V and a strictly transverse system carrying information on field-circulation. This specialized Chandrasekhar-Kendall representation defines Habs and permits a neat formulation of the boundary-value problem (BVP) for the Taylor state as a constant-α force-free field, treating 3D wholly-contained and anchored fields on the same conceptual basis. In this formulation, the governing equation is a scalar integro-partial differential equation (PDE). A family of series solutions for an anchored field is presented as an illustration of this class of BVPs. Past treatments of the constant-α field in 3D cylindrical geometry are based on a scalar Helmholtz PDE as the governing equation, with issues of inconsistency in the published field solutions discussed over time in the journal literature. The constant-α force-free equation reduces to a scalar Helmholtz PDE only as special cases of the 3D integro-PDE derived here. In contrast, the constant-α force-free equation and the scalar Helmholtz PDE are absolutely equivalent in the spherical domain as discussed in Appendix. This theoretical study is motivated by the investigation of the Sun's corona but the results are also relevant to laboratory plasmas.

  6. Comparison of prognostic impact of absolute lymphocyte count, absolute monocyte count, absolute lymphocyte count/absolute monocyte count prognostic score and ratio in patients with diffuse large B cell lymphoma.

    Science.gov (United States)

    Markovic, Olivera; Popovic, Lazar; Marisavljevic, Dragomir; Jovanovic, Darjana; Filipovic, Branka; Stanisavljevic, Dejana; Matovina-Brko, Gorana; Hajder, Jelena; Matkovic, Tatjana; Živkovic, Radmila; Stanisavljevic, Natasa; Todorović, Milena; Petrovic, Dragana; Mihaljevic, Biljana

    2014-03-01

    The combination of absolute lymphocyte count (ALC) and absolute monocyte count (AMC) at diagnosis has prognostic relevance in patients with diffuse large B cell lymphoma (DLBCL). The present study was designed to investigate the prognostic significance of ALC and AMC and to determine whether ALC/AMC ratio or ALC/AMC prognostic score is better predictor of outcome in DLBCL. We retrospectively analyzed the prognostic significance of ALC and AMC, ALC/AMC ratio and ALC/AMC prognostic score at diagnosis in 222 DLBCL patients treated with R-CHOP. ROC analysis showed that optimal cut-off values of AMC and ALC/AMC ratio with the best sensitivity and specificity were 0.59×10(9)/L and 2.8, respectively. Cut-off of ALC was determined according to the literature data (1×10(9)/L). Low ALC, high AMC, low ALC/AMC ratio and high ALC/AMC prognostic score were in significant association with lower rate of therapy response and survival. In contrast, these parameters were not in significant correlation with relapse rate. The patients with low ALC, "high" AMC, low ALC/AMC ratio and high ALC/AMC prognostic score at diagnosis had significantly shorter EFS and OS. In multivariate analysis all tested parameters (ALC, AMC, ALC/AMC prognostic score and ALC/AMC ratio) are independent risk factors along with "bulky" disease and IPI. All tested parameters (ALC, AMC, ALC/AMC score and ALC/AMC ratio) may be useful prognostic factors in DLBCL patients. ALC/AMC score has a slight advantage as it allows the classification of patients into three prognostic groups. Further studies are needed to determine which of these parameters has the highest predictive value. Copyright © 2014 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  7. Recent developments in time-frequency analysis

    CERN Document Server

    Loughlin, Patrick

    1998-01-01

    Recent Developments in Time-Frequency Analysis brings together in one place important contributions and up-to-date research results in this fast moving area. Recent Developments in Time-Frequency Analysis serves as an excellent reference, providing insight into some of the most challenging research issues in the field.

  8. Testing hypotheses on frequency effects in first language acquisition

    DEFF Research Database (Denmark)

    Kjærbæk, Laila; Basbøll, Hans

    2015-01-01

    On the basis of extensive literature studies, Ambridge, Kidd, Rowland and Theakston (2015) present five theses on frequency effects on language acquisition: i) the Levels and Kinds Thesis argues that frequency effects exist at all levels and are of many different kinds (e.g., type and token...... frequency effects as well as absolute and relative frequency effects); ii) the Age of Acquisition Thesis argues that all other things being equal, frequent forms will be acquired before less frequent forms. Since all other things are not equal, this claim does not entail a one-to-one relationship between...... frequency and age of acquisition; iii) the Prevent Error Thesis argues that high-frequency forms prevent (or reduce) errors in contexts in which they are the target; iv) the Cause Error Thesis argues that high-frequency forms also cause errors in contexts in which a competing, related lower-frequency form...

  9. An absolute index (Ab-index to measure a researcher's useful contributions and productivity.

    Directory of Open Access Journals (Sweden)

    Akshaya Kumar Biswal

    Full Text Available Bibliographic analysis has been a very powerful tool in evaluating the effective contributions of a researcher and determining his/her future research potential. The lack of an absolute quantification of the author's scientific contributions by the existing measurement system hampers the decision-making process. In this paper, a new metric system, Absolute index (Ab-index, has been proposed that allows a more objective comparison of the contributions of a researcher. The Ab-index takes into account the impact of research findings while keeping in mind the physical and intellectual contributions of the author(s in accomplishing the task. The Ab-index and h-index were calculated for 10 highly cited geneticists and molecular biologist and 10 young researchers of biological sciences and compared for their relationship to the researchers input as a primary author. This is the first report of a measuring method clarifying the contributions of the first author, corresponding author, and other co-authors and the sharing of credit in a logical ratio. A java application has been developed for the easy calculation of the Ab-index. It can be used as a yardstick for comparing the credibility of different scientists competing for the same resources while the Productivity index (Pr-index, which is the rate of change in the Ab-index per year, can be used for comparing scientists of different age groups. The Ab-index has clear advantage over other popular metric systems in comparing scientific credibility of young scientists. The sum of the Ab-indices earned by individual researchers of an institute per year can be referred to as Pr-index of the institute.

  10. Absolute local sea surface in the Vanuatu Archipelago from GPS, satellite altimetry and pressure gauge data

    Science.gov (United States)

    Cheng, K. K.; Ballu, V.; Bouin, M.; Calmant, S.; Shum, C.

    2004-12-01

    Water height measurements provided by seafloor tide gauges are a combination of sea level variation and local ground motion. Both signals are of scientific interest, but they must be separated in order to be useful. A reliable estimation of the vertical ground motion is important in very seismically areas such as the Pacific Ocean rim. One promising method to separate the two contributions is to use satellite altimetry which gives absolute water height that is independent of the local ground motion. However, the altimeter data must be calibrated using ground truth measurements. Once different components of the signal are separated, bottom pressure gauges can be used to detect vertical movements of the seafloor. The Vanuatu Archipelago is part of the Pacific "ring of fire", where plates are quickly converging. In this area, movements are very rapid and the seismic activity is intense, which gives a good opportunity to study deformation and seismic cycle. To get an integrate picture of vertical deformation over one plate and between the two plates, one needs to be able to monitor vertical movements on both underwater and emerged areas. We conducted an experiment in this area to compare measurements from bottom pressure gauges located beneath altimetry satellite tracks with sea surface altitude measurements from GPS. Two bottom pressure gauge are immerged since Nov. 1999 in this region. In order to perform absolute calibration for multiple satellite altimeters that overfly the region, we conducted 2 campaigns of GPS measurements of instantaneous sea surface height onboard the R/V Alis and using a GPS buoy. We present results of GPS computations for the March 2003 and March 2004 campaigns. These sea level GPS measurements are compared with multiple altimeter-measured sea surface heights, and sampling differences and high frequency variations were removed using continuous pressure gauge data. The observed discrepancies are likely to be explained by local geoid

  11. Absolute Paleointensity Study of Miocene Tiva Canyon Tuff, Yucca Mountain, Nevada

    Science.gov (United States)

    Patiman, A.; Bowles, J.

    2014-12-01

    Unoriented samples from the ~12.7 Ma Tiva Canyon (TC) tuff from Yucca Mountain, Nevada are studied in terms of magnetic properties and geomagnetic paleointensity. The magnetic mineralogy and magnetic properties of the TC tuff have previously been well documented, and the remanence-carrier in ~15-m thick zones at the top and bottom of the unit is dominantly is single domain (SD) to superparamagnetic (SP) magnetite, which may be considered ideal for absolute paleointensity studies. Among one of the several episodic volcanic eruptions of the Southwestern Nevada Volcanic Field (SWNVF), the welded TC tuff belongs to the Paintbrush Group. Here we present magnetic properties from two previously unreported sections of the TC tuff, as well as Thellier-type absolute paleointensity estimates. Samples were collected from the lower ~7 m at the base of the flow. Magnetic properties studied include hysteresis, bulk magnetic susceptibility, frequency-dependent susceptibility, and anhysteretic remanent magnetization acquisition. Magnetic property results are consistent with earlier work, showing that the main magnetic mineral is magnetite. SP samples are dominant from the lower ~1 m to ~3.6 m basal unit while the middle unit of ~3.7 m to 7.0 m mainly consists of SD samples. The paleointensity results are closely tied to the stratigraphic height and magnetic properties linked to domain state. The SD samples have consistent absolute paleointensity values 32.40±0.22 uT, VADM 5.74*1022 A.m2 and behaved ideally during paleointensity experiments. The SP samples have consistently higher paleointensity and less ideal behavior, but would likely pass many traditional quality-control tests. Since the magnetite has been interpreted to form by precipitation out of the glass post-emplacement, but at temperatures higher than the Curie temperature, we tentatively interpret the SD remanence to be a primary thermal remanent magnetization and the paleointensity result to be a valid estimate of

  12. Regional and site-specific absolute humidity data for use in tritium dose calculations

    International Nuclear Information System (INIS)

    Etnier, E.L.

    1980-01-01

    Due to the potential variability in average absolute humidity over the continental U.S., and the dependence of atmospheric 3 H specific activity on absolute humidity, availability of regional absolute humidity data is of value in estimating the radiological significance of 3 H releases. Most climatological data are in the form of relative humidity, which must be converted to absolute humidity for dose calculations. Absolute humidity was calculated for 218 points across the U.S., using the 1977 annual summary of U.S. Climatological Data, and is given in a table. Mean regional values are shown on a map. (author)

  13. LINQ Pocket Reference

    CERN Document Server

    Albahari, Joseph

    2008-01-01

    Ready to take advantage of LINQ with C# 3.0? This guide has the detail you need to grasp Microsoft's new querying technology, and concise explanations to help you learn it quickly. And once you begin to apply LINQ, the book serves as an on-the-job reference when you need immediate reminders. All the examples in the LINQ Pocket Reference are preloaded into LINQPad, the highly praised utility that lets you work with LINQ interactively. Created by the authors and free to download, LINQPad will not only help you learn LINQ, it will have you thinking in LINQ. This reference explains: LINQ's ke

  14. Regular Expression Pocket Reference

    CERN Document Server

    Stubblebine, Tony

    2007-01-01

    This handy little book offers programmers a complete overview of the syntax and semantics of regular expressions that are at the heart of every text-processing application. Ideal as a quick reference, Regular Expression Pocket Reference covers the regular expression APIs for Perl 5.8, Ruby (including some upcoming 1.9 features), Java, PHP, .NET and C#, Python, vi, JavaScript, and the PCRE regular expression libraries. This concise and easy-to-use reference puts a very powerful tool for manipulating text and data right at your fingertips. Composed of a mixture of symbols and text, regular exp

  15. CSS Pocket Reference

    CERN Document Server

    Meyer, Eric

    2011-01-01

    When you're working with CSS and need a quick answer, CSS Pocket Reference delivers. This handy, concise book provides all of the essential information you need to implement CSS on the fly. Ideal for intermediate to advanced web designers and developers, the 4th edition is revised and updated for CSS3, the latest version of the Cascading Style Sheet specification. Along with a complete alphabetical reference to CSS3 selectors and properties, you'll also find a short introduction to the key concepts of CSS. Based on Cascading Style Sheets: The Definitive Guide, this reference is an easy-to-us

  16. Olfactory Reference Syndrome

    Directory of Open Access Journals (Sweden)

    Alper Evrensel

    2015-12-01

    Full Text Available Olfactory reference syndrome is a delusional disorder in which the patient persistently and falsely believes that his or her body emits a foul odor. The disease is considered a variant of somatic type of delusional disorder under the diagnostic systems. Similarities between olfactory reference syndrome and obsessive compulsive disorder have also been noted. The etiopathogenesis of the disorder has not yet been clarified. Antidepressants, antipsychotics and psychotherapy are used in the treatment of this disorder. The aim of this article was to review clinical features, neurobiology, differantial diagnosis, classification problems and treatment of olfactory reference syndrome.

  17. Windows Powershell Pocket Reference

    CERN Document Server

    Holmes, Lee

    2009-01-01

    This portable reference to Windows PowerShell summarizes both the command shell and scripting language, and provides a concise reference to the major tasks that make PowerShell so successful. Written by Microsoft PowerShell team member Lee Holmes, and excerpted from his Windows PowerShell Cookbook, Windows PowerShell Pocket Reference offers up-to-date coverage of PowerShell's 1.0 release. It's an ideal on-the-job tool for Windows administrators who don't have time to plow through huge books or search online.

  18. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  19. R quick syntax reference

    CERN Document Server

    Tollefson, Margot

    2014-01-01

    The R Quick Syntax Reference is a handy reference book detailing the intricacies of the R language. Not only is R a free, open-source tool, R is powerful, flexible, and has state of the art statistical techniques available. With the many details which must be correct when using any language, however, the R Quick Syntax Reference makes using R easier.Starting with the basic structure of R, the book takes you on a journey through the terminology used in R and the syntax required to make R work. You will find looking up the correct form for an expression quick and easy. With a copy of the R Quick

  20. Underwater Sound Reference Division

    Data.gov (United States)

    Federal Laboratory Consortium — The Underwater Sound Reference Division (USRD) serves as the U.S. standardizing activity in the area of underwater acoustic measurements, as the National Institute...

  1. Toxicity Reference Database

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Toxicity Reference Database (ToxRefDB) contains approximately 30 years and $2 billion worth of animal studies. ToxRefDB allows scientists and the interested...

  2. Genetics Home Reference: adermatoglyphia

    Science.gov (United States)

    ... individuals have had difficulty entering countries that require fingerprinting for identification. In some families, adermatoglyphia occurs without ... Genetics Home Reference Celebrates Its 15th Anniversary National DNA Day 2018 Newborn Screening Saves Lives Act Turns ...

  3. Python essential reference

    CERN Document Server

    Beazley, David M

    2009-01-01

    Python Essential Reference is the definitive reference guide to the Python programming language — the one authoritative handbook that reliably untangles and explains both the core Python language and the most essential parts of the Python library. Designed for the professional programmer, the book is concise, to the point, and highly accessible. It also includes detailed information on the Python library and many advanced subjects that is not available in either the official Python documentation or any other single reference source. Thoroughly updated to reflect the significant new programming language features and library modules that have been introduced in Python 2.6 and Python 3, the fourth edition of Python Essential Reference is the definitive guide for programmers who need to modernize existing Python code or who are planning an eventual migration to Python 3. Programmers starting a new Python project will find detailed coverage of contemporary Python programming idioms.

  4. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  5. Reflectance Reference Targets (OTTER)

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Spectral reflectance measurements of flat field targets as reference points representative of pseudo-invariant targets as measured by Spectron SE590...

  6. Reflectance Reference Targets (OTTER)

    Data.gov (United States)

    National Aeronautics and Space Administration — Spectral reflectance measurements of flat field targets as reference points representative of pseudo-invariant targets as measured by Spectron SE590 spectrophotometer

  7. Genetics Home Reference: coloboma

    Science.gov (United States)

    ... 447-70. Review. Citation on PubMed Gongal PA, French CR, Waskiewicz AJ. Aberrant forebrain signaling during early ... 3):191-7. Citation on PubMed More from Genetics Home Reference Bulletins March is Trisomy Awareness Month ...

  8. Reference Climatological Stations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Reference Climatological Stations (RCS) network represents the first effort by NOAA to create and maintain a nationwide network of stations located only in areas...

  9. Enterprise Reference Library

    Science.gov (United States)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and

  10. Electronics engineer's reference book

    CERN Document Server

    Turner, L W

    1976-01-01

    Electronics Engineer's Reference Book, 4th Edition is a reference book for electronic engineers that reviews the knowledge and techniques in electronics engineering and covers topics ranging from basics to materials and components, devices, circuits, measurements, and applications. This edition is comprised of 27 chapters; the first of which presents general information on electronics engineering, including terminology, mathematical equations, mathematical signs and symbols, and Greek alphabet and symbols. Attention then turns to the history of electronics; electromagnetic and nuclear radiatio

  11. 2002 reference document

    International Nuclear Information System (INIS)

    2002-01-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  12. Reference Man anatomical model

    Energy Technology Data Exchange (ETDEWEB)

    Cristy, M.

    1994-10-01

    The 70-kg Standard Man or Reference Man has been used in physiological models since at least the 1920s to represent adult males. It came into use in radiation protection in the late 1940s and was developed extensively during the 1950s and used by the International Commission on Radiological Protection (ICRP) in its Publication 2 in 1959. The current Reference Man for Purposes of Radiation Protection is a monumental book published in 1975 by the ICRP as ICRP Publication 23. It has a wealth of information useful for radiation dosimetry, including anatomical and physiological data, gross and elemental composition of the body and organs and tissues of the body. The anatomical data includes specified reference values for an adult male and an adult female. Other reference values are primarily for the adult male. The anatomical data include much data on fetuses and children, although reference values are not established. There is an ICRP task group currently working on revising selected parts of the Reference Man document.

  13. Absolute Thermal SST Measurements over the Deepwater Horizon Oil Spill

    Science.gov (United States)

    Good, W. S.; Warden, R.; Kaptchen, P. F.; Finch, T.; Emery, W. J.

    2010-12-01

    Climate monitoring and natural disaster rapid assessment require baseline measurements that can be tracked over time to distinguish anthropogenic versus natural changes to the Earth system. Disasters like the Deepwater Horizon Oil Spill require constant monitoring to assess the potential environmental and economic impacts. Absolute calibration and validation of Earth-observing sensors is needed to allow for comparison of temporally separated data sets and provide accurate information to policy makers. The Ball Experimental Sea Surface Temperature (BESST) radiometer was designed and built by Ball Aerospace to provide a well calibrated measure of sea surface temperature (SST) from an unmanned aerial system (UAS). Currently, emissive skin SST observed by satellite infrared radiometers is validated by shipborne instruments that are expensive to deploy and can only take a few data samples along the ship track to overlap within a single satellite pixel. Implementation on a UAS will allow BESST to map the full footprint of a satellite pixel and perform averaging to remove any local variability due to the difference in footprint size of the instruments. It also enables the capability to study this sub-pixel variability to determine if smaller scale effects need to be accounted for in models to improve forecasting of ocean events. In addition to satellite sensor validation, BESST can distinguish meter scale variations in SST which could be used to remotely monitor and assess thermal pollution in rivers and coastal areas as well as study diurnal and seasonal changes to bodies of water that impact the ocean ecosystem. BESST was recently deployed on a conventional Twin Otter airplane for measurements over the Gulf of Mexico to access the thermal properties of the ocean surface being affected by the oil spill. Results of these measurements will be presented along with ancillary sensor data used to eliminate false signals including UV and Synthetic Aperture Radar (SAR

  14. Recommended reference materials for realization of physicochemical properties density

    CERN Document Server

    Herington, E F G

    1976-01-01

    This book first presents the nomenclature and units used in the determination of densities of liquids and solids, followed by a general description of the apparatus and the methods used in the measurement of density, with particular reference to the pycnometric, hydrostatic weighing, magnetic float, and temperature flotation methods. The use of water as a density reference material is then explained, focusing on the isotopic composition of Standard Mean Ocean Water (SMOW) and the absolute density of SMOW as a function of temperature. Problems due to the effect of pressure and dissolved gases o

  15. On quantum harmonic oscillator being subjected to absolute ...

    Indian Academy of Sciences (India)

    In this paper, assuming a boundary condition that the product of momentum and position, or the product of energy density and position remains constant in the QHO, it is established that a particle subjected to increasing frequencies becomes gradually subtler to transform into a very high dormant potential energy. This very ...

  16. Absolute quantum yield measurements for the formation of oxygen ...

    Indian Academy of Sciences (India)

    ... under collision-free conditions by vacuum ultraviolet laser-induced fluorescence. The use of narrow-band probe laser radiation, generated via resonant third-order sum-difference frequency conversion of dye laser radiation in Krypton, allowed the measurement of the nascent O(3P=2,1,0) fine-structure state distribution: ...

  17. On quantum harmonic oscillator being subjected to absolute

    Indian Academy of Sciences (India)

    In a quantum harmonic oscillator (QHO), the energy of the oscillator increases with increased frequency. In this paper, assuming a boundary condition that the product of momentum and position, or the product of energy density and position remains constant in the QHO, it is established that a particle subjected to increasing ...

  18. Greening the NetFPGA Reference Router

    Directory of Open Access Journals (Sweden)

    Feng Guo

    2016-06-01

    Full Text Available Energy efficiency is an important criterion in the design of next generation networks for both economic and environmental concerns. This paper presents an energy-efficient router that is able to dynamically adapt its routing capability in response to real-time traffic load, achieving energy proportional routing. The NetFPGA reference router, which operates at one of two frequencies (125 MHz or 62.5 MHz, requires a board reset to switch frequencies. We have modified the reference router to allow dynamic switching among five operating frequencies. Experiments with real traces indicate that, compared to the reference router, a 10% power reduction can be achieved through dynamic frequency scaling. When the router is further modified to support green traffic engineering and Ethernet port shut-down, power consumption can be reduced by 46% while maintaining the required quality of service. This allows the router to meet the instantaneous performance requirements while minimizing power dissipation. Similar results can be expected when these general power-saving principles are applied in future commercial routers.

  19. Gravitational acceleration as a cue for absolute size and distance?

    Science.gov (United States)

    Hecht, H.; Kaiser, M. K.; Banks, M. S.

    1996-01-01

    When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.

  20. Absolute Dimensions of Contact Binary Stars in Baade Window

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    1999-12-01

    Full Text Available The light curves of the representative 6 contact binary stars observed by OGLE Project of searching for dark matter in our Galaxy have been analyzed by the method of the Wilson and Devinney Differential Correction to find photometric solutions. The orbital inclinations of these binaries are in the range of 52 deg - 69 deg which is lower than that of the solar neighborhood binaries. The Roche lobe filling factor of these binaries are distributed in large range of 0.12 - 0.90. Since absence of spectroscopic observations for these binaries we have found masses of the 6 binary systems based on the intersection between Kepler locus and locus derived from Vandenberg isochrones in the mass - luminosity plane. Then absolute dimensions and distances have been found by combining the masses and the photometric solutions. The distances of the 6 binary systems are distributed in the range of 1 kpc - 6 kpc. This distance range is the limiting range where the contact binaries which have period shorter than a day are visible. Most contact binaries discovered in the Baade window do not belong to the Galactic bulge.