WorldWideScience

Sample records for abnormal technetium pyrophosphate

  1. Increased incidence and clinical correlation of persistently abnormal technetium pyrophosphate myocardial scintigrams following acute myocardial infarction in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Nicod, P.; Lewis, S.E.; Corbett, J.C.; Buja, L.M.; Henderson, G.; Raskin, P.; Rude, R.E.; Willerson, J.T.

    1982-01-01

    Persistently abnormal /sup 99m/Tc stannous pyrophosphate myocardial scintigrams (PPi+) appear to be associated with a relatively poor prognosis after acute myocardial infarction (AMI). To assess the incidence and implications of PPi+, we performed a retrospective analysis in 29 patients with and 25 patients without diabetes mellitus who had abnormal myocardial scintigrams within 4 days of AMI and who had follow-up scintigrams at least 3 months after hospital discharge. There were no significant differences between patients with and without diabetes as regards age, incidence of transmural or nontransmural AMI, or degree of left ventricular dysfunction after AMI. Persistently abnormal PPi+ occurred more commonly in patients with diabetes than in nondiabetic patients (18 of 29, 62%, compared to 3 of 25, 12%; p less than 0.001). Patients with chronic PPi+ had more frequent cardiac complications following hospital discharge (p less than 0.005) including death, recurrent AMI, unstable angina, and intractable congestive heart failure. Postmortem analysis in two patients with diabetes and chronic PPi+ revealed marked myocytolysis. Thus, patients with diabetes mellitus have an increased incidence of post-AMI persistently abnormal technetium (PPi+) scintigrams and relatively poor prognosis following myocardial infarction

  2. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  3. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  4. Ligand-free, protein-bound technetium-99m iron-dextran enhancement of technetium pyrophosphate uptake in tumours

    International Nuclear Information System (INIS)

    Pojer, P.M.; Jakovljevic, A.C.; Wise, K.N.

    1985-01-01

    The biodistribution of technetium-99m was studied in T-cell lymphoma and selected organs of iron-dextran treated and control mice given technetium-99m pyrophosphate. The results showed that high serum iron levels increased tumour uptake of technetium pyrophosphate. This supports the hypothesis that technetium, in common with other metal-based tumour seeking radiopharmaceuticals, is transported to tumours as a ligand-free protein-bound cation. (U.K.)

  5. Investigation of the interaction of hydroxyapatite with technetium in association with stannous pyrophosphate

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Jette, D.; Somers, E.

    1981-01-01

    The individual components of technetium-99m stannous pyrophosphate were studied with respect to their interaction with hydroxyapatite. It is demonstrated that the role of the pyrophosphate molecule is one of a solubilizing and transporting molecule to carry the technetium atom to the site of the hydroxyapatite where the chelate disassociates and both the pyrophosphate and the technetium individually bind to the hydroxyapatite. The stannous ion is shown to associate with the hydroxyapatite also and although also solubilized by the pyrophosphate appears to be less strongly associated with the pyrophosphate. (author)

  6. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  7. Technetium-99m-pyrophosphate myocardial imaging in unstable angina

    International Nuclear Information System (INIS)

    Willerson, J.T.; Parkey, R.W.; Lewis, S.E.; Buja, L.M.; Bonte, F.J.

    1980-01-01

    The authors have found that approximately one third of patients with the syndrome of unstable angina pectoris have abnormal 99mTc-pyrophosphate myocardial scintigrams even in the absence of abnormal enzymes and electrocardiographic confirmation of the presence of acute myocardial necrosis. Thus, 99mTc-pyrophosphate myocardial imaging technique appears to represent a sensitive means to detect acute multicellular injury associated with the clinical syndrome of unstable angina pectoris even when cardiac enzymes are normal and the electrocardiogram does not definitively document the presence of acute myocardial necrosis. (Auth.)

  8. Technetium 99m pyrophosphate bone scintigraphy in the exploration of breast cancer bone metastases (analysis of 311 examinations)

    International Nuclear Information System (INIS)

    Bonichon, Francoise.

    1976-01-01

    Sodium pyrophosphate was chosen for its ease of application and the quality of the images it gives. The aim of this study, in the context of breast cancer exploration, is to examine: - its reliability for the detection of bone metastases, - the correlation of its results with other factors. The first part reviews the properties of sup(99m)Tc-labelled sodium pyrophosphate and the current hypotheses on the mechanism of its bone fixation, essential for an understanding of the image formation mechanism and for the interpretation of anomalies. Part two gives an analysis of 311 examinations carried out on 223 patients, obtained by the use of a coded file and modern data processing methods. The following are dealt with in turn: - material and methods, - the results themselves and especially their reliability for the whole skeleton and for one bone at a time, - discussion and comparison with published data. Sup(99m)Tc pyrophosphate bone scintigraphy is a simple examination easy to interpret and allows the whole skeleton to be explored. Abnormal scintigraphic images are: - seldom hypofixing lacunae, - usually 'hyperfixing centres' which point to a perilesional bone reaction and depend on: vascular factors, the affinity of technetium for the immature collagen fibres of the forming bone matrix, the affinity of pyrophosphate for the bone mineral substance [fr

  9. Technetium-99m--pyrophosphate bone scans in hyperparathyroidism

    International Nuclear Information System (INIS)

    Wiegmann, T.; Rosenthall, L.; Kaye, M.

    1977-01-01

    Most patients with primary hyperparathyroidism have normal 5-hr bone-to-soft-tissue ratios for /sup 99m/Tc-pyrophosphate. In contrast, all five patients with advanced secondary hyperparathyroidism in this study showed significant (p less than 0.001) increases of bone uptake. In the early period after parathyroidectomy, there was no quantitative or qualitative change in uptake. A limited decrease of bone uptake was observed only after prolonged periods of observation. In itself, parathyroid activity seems to have little direct influence on bone uptake of /sup 99m/Tc-pyrophosphate

  10. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    International Nuclear Information System (INIS)

    Patel, R.; Mishkin, F.S.

    1986-01-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal

  11. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Mishkin, F.S.

    1986-10-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal.

  12. Contribution of technetium pyrophosphate bone scintigraphy in the evaluation of prostate cancer extension based on 100 cases

    International Nuclear Information System (INIS)

    Oliveux, Alain.

    1976-01-01

    The aim of this work was to compare the results of technetium 99m pyrophosphate bone scintigraphy with those of the standard radiographic exploration of the skeleton in order to find out whether scintigraphic data allow an earlier and more accurate diagnosis of the presence of bone metastases. The dose administered is about 10MCi per patient; the recording is made 4 hours after intraveinous injection of the tracer. The documents are obtained in two stages: - first of all a whole-body scintigraph is carried out by means of an 'omniview' system adapted to the Picker dynacamera. This instrument gives an image of the entire body by translation of the patient's bed before the detection head of the camera; - immediately after the whole-body scan a series of static views is taken, especially on abnormal or doubtful areas. These documents have a better resolution than the reduced whole-body image and supply complementary data all the more valuable as they are directed towards the zones of interest. Analysis of our observations underlines the advantages of technetium 99m pyrophosphate bone scintigraphy in the evaluation of prostate neoplasm extension. This particularly sensitive method of investigation enables bone metastases to be detected earlier and more precisely in a patient presenting a neoplasm [fr

  13. Recognition of reversible and irreversible myocardial injury by technetium pyrophosphate extraction kinetics

    International Nuclear Information System (INIS)

    Silva, R.; Chen, Y.F.; Sell, T.L.; Lowe, J.E.; Jones, R.H.

    1987-01-01

    The need for a more accurate method of detecting episodes of myocardial ischemia during cardiac operations, particularly during the ischemic arrest interval, prompted us to investigate the usefulness of measuring the active extraction of technetium pyrophosphate in identifying and quantitating ischemic injury. Twenty-four adult mongrel dogs were subjected to cardiopulmonary bypass, and normothermic global ischemia was induced by cross-clamping the proximal aorta. Technetium pyrophosphate (1 mCi) was injected through a standard cardioplegia line with normal saline, simulating administration of cardioplegic solution, upon placement of the aortic cross-clamp (time 0), at 15, 30, 45, and 60 minutes of global ischemia, and with the onset and completion of ischemic contracture. Radioactive counts were recorded over the heart at 1 second intervals, and the extraction fraction and half-time of clearance were calculated. The extraction fraction increased from 0.22 at time 0 to 0.58 at 15 minutes, 0.82 at 30 minutes, 0.85 at 45 minutes, and 0.91 at 60 minutes. The halftime increased from a baseline of 114 seconds (time 0) to a maximum of 321 seconds at 60 minutes of ischemia. The onset and completion of ischemic contracture showed a return toward baseline of both the extraction fraction and halftime of clearance, with an extraction fraction of 0.44 and 0.46 and a halftime of 135 and 133 seconds, respectively. These data clearly show that reversible myocardial injury increased the extraction and reduced the clearance of technetium pyrophosphate and that the magnitude of change related to the extent of injury. The progression to irreversible myocardial injury decreased the active extraction of technetium pyrophosphate. This simple procedure for real-time documentation of myocardial injury promises to provide easily obtainable endpoints of injury for use during cardiac operations in humans

  14. Myocardial scintigraphy using pyrophosphate-technetium 99m. 367 cases

    Energy Technology Data Exchange (ETDEWEB)

    Degeorges, M; Roucayrol, J C; Sol, C; Comet, M; Vassilopoulos, J [Hopital Cochin, 75 - Paris (France)

    1977-04-30

    Pyrophosphate-sup(99m)Tc injected intravenously, is almost invariably fixed in the infarcted zone in transmural infarctions less than 8 days old. Fixation occurs in only 2/3 of cases of rudimentary infarction. The degree of fixation is more or less proportional to the size of the peak of creatine phosphokinase. After the 8th day following infarction, fixation is slight or nil. It is inconstant in pre-infarction syndrome or simple angina. This examination complements clinical, electrocardiographic and enzyme findings, in particular in the case of difficult diagnosis.

  15. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Dalton, D.R.

    1981-01-01

    The amount of tin(II) required for adequate reduction, complexation, and stability of technetium Tc 99m pertechnetate in radiopharmaceutical kits, and methods of preventing the loss of tin(II) during formulation of these lyophilized kits are investigated. Tin(II) loss from stannous chloride solutions was studied under several conditions, including room air versus nitrogen atmospheres, during vial filling in a laminar-flow hood with samples frozen on dry ice versus samples at room temperature, during lyophilization, and during storage under refrigerated, ambient, and elevated temperatures. Various amounts of stannous chloride, ranging from 5 to 1000 microgram/ml, were used in formulating sodium pertechnetate Tc 99m kits containing 100 mCi technetium Tc 99m and 0.4 microgram total technetium. Samples were removed at various times; hydrolyzed technetium, pertechnetate, and technetium Tc 99m pyrophosphate were isolated on instant thin-layer chromatography-silica gel and quantified with a scintillation counter. The time necessary to deoxygenate distilled water by nitrogen purging was measured. Several sources of stannous chloride were assayed for tin(II) content. Tin(II) loss occurs rapidly in solution (15% in one hour) unless continuously protected with nitrogen, and during vial filling in a laminar-flow hood unless frozen with dry ice. No substantial loss of tin(II) was detected during lyophilization or during storage of lyophilized product at any of the three temperatures. A minimum of 400 microgram tin(II) was required to provide 90% technetium Tc 99m pyrophosphate at six hours after preparation. Adequate deoxygenation of small quantities (450 ml) of water was accomplished in less than one hour. Some stannous chloride salts were highly oxidized in the dry state, and only high-purity elemental tin wire gave acceptable yields of tin

  16. Complexes of technetium with pyrophosphate, etidronate, and medronate

    International Nuclear Information System (INIS)

    Russell, C.D.; Cash, A.G.

    1979-01-01

    The reduction of [ 99 Tc]pertechnetate was studied as a function of pH in complexing media of pyrophosphate, methylene diphosphonate (MDP), and ethane-1, hydroxy-1, and 1-diphosphonate (HEDP). Test (sampled d-c) and normal-pulse polarography were used to study the reduction of pertechnetate, and normal-pulse polarography (sweeping in the anodic direction) to study the reoxidation of the products. Below pH 6 TcO 4 - was reduced to Tc(III), which could be reoxidized to Tc(IV). Above pH 10, TcO 4 - was reduced in two steps to Tc(V) and Tc(IV), each of which could be reoxidized to TcO 4 - . Between pH 6 and 10 the results differed according to the ligand present. In pyrophosphate and MDP, TcO 4 - was reduced in two steps to Tc(IV) and Tc(III); Tc(III) could be reoxidized in two steps to Tc(IV) and TcO 4 - . In HEDP, on the other hand, TcO 4 - was reduced in two steps to Tc(V) and Tc(III), and could be reoxidized to Tc(IV) and TcO 4 - . Additional waves were observed; they apparently led to unstable products

  17. Contribution of technetium 99m-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Capdepont, M.-T.

    1976-01-01

    This work examines the contribution of technetium 99m(sup(99m)Tc)-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis and attempts to define its importance in the diagnosis of lesions and their subsequent supervision in patients under treatment. 5 to 15 millicuries of sup(99m)Tc-labelled pyrophosphates are injected intraveinously. Bone uptake is strong and durable; 1.3% of the injected activity is found in the blood by the fifth hour. The skeleton may be explored: - either one segment at a tome with a scintillation camera, - or all at once and more quickly with a whole-body device taking front and black exposures. Bone scintigraphy appears as a basic technique in the study of infectious spondylodiscitis. Moreover the use of increasingly efficient equipment, the quantification of results and perhaps the development of new tracers augur well for a technique which is already acknowledged to be of fundamental interest [fr

  18. Diagnostic value of technetium pyrophosphate bone scintigraphy. Study of 277 patients

    International Nuclear Information System (INIS)

    Sainte-Croix, Annick.

    1975-01-01

    277 bone scintigraphs were carried out with 99m technetium pyrophosphate and an attempt was made, on the basis of this experience, to define the advantages and limits of the technique. 99m technetium pyrophosphate seems to be the isotope most suitable for bone scintigraphy. The scintillation camera bone scintigraphic examination is simple, allowing the whole skeleton to be explored in a relatively short time, and above all harmless since the total irradiation to which the organism is exposed throughout is no more than 0.07 rad. The broadest field of application of bone scintigraphy appears to be cancer: in 45 cases out of 66 it revealed bone metastases invisible radiologically and in 28 cases out of 90 the number of metastases observed was greater than that shown by X-rays. In 11 cases however radiologically visible bone metastases were not detected by scintigraphy. In spite of this reservation we consider bone scintigraphy to be a valuable technique, more sensitive than X-ray examinations in the detection of bone metastases of cancers [fr

  19. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  20. Early estimation of acute myocardial infarct size soon after coronary reperfusion using emission computed tomography with technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kambara, H.; Fudo, T.; Tamaki, S.; Nohara, R.; Takatsu, Y.; Hattori, R.; Tokunaga, S.; Kawai, C.

    1987-01-01

    Early appearance of positive findings on a technetium-99m pyrophosphate scan has been shown to be associated with the presence of a reperfused acute myocardial infarction (AMI). Early technetium-99m pyrophosphate imaging was performed by emission computed tomography to evaluate reperfusion and to test the feasibility of estimating infarct size soon after coronary reperfusion based on acute positive tomographic findings. Twenty-seven patients with transmural AMI who were treated with intracoronary urokinase infusion followed by percutaneous transluminal coronary angioplasty underwent pyrophosphate imaging 8.7 +/- 2.1 hours after the onset of AMI. None of the 8 patients in whom reperfusion was unsuccessful had acute positive findings. Of 19 patients in whom reperfusion was successful, 17 had acute positive findings (p less than 0.001). In these 17, tomographic infarct volumes were determined from reconstructed transaxial images. The threshold for areas of increased pyrophosphate uptake within the infarct was set at 60% of peak activity by the computerized edge-detection algorithm. The total number of pixels in all transaxial sections showing increased tracer uptake were added and multiplied by a size factor and 1.05 g/cm3 muscle to determine infarct volume. The correlations of tomographic infarct volumes with peak serum creatine kinase (CK) levels (r = 0.82) and with cumulative release of CK-MB isoenzyme (r = 0.89) were good. Moreover, the time to positive imaging was significantly shorter than that to peak CK level (8.5 +/- 2.3 vs 10.4 +/- 2.2 hours, p less than 0.005)

  1. Effect of EHDP on calcium accumulation and technetium-99m pyrophosphate uptake in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Buja, L.M.; Tofe, A.J.; Parkey, R.W.; Francis, M.D.; Lewis, S.E.; Kulkarni, P.V.; Bonte, F.J.; Willerson, J.T.

    1981-01-01

    Ethane-l-hydroxy-1,1-diphosphonate (EHDP) inhibits bone mineral growth. This study was performed to test the hypothesis that EHDP would interfere with the process of calcium uptake and deposition in evolving myocardial infarction and thereby influence other parameters, including technetium-99m pyrophosphate (Tc-99m PYP) uptake and scintigraphic visualization of the infarcts. Permanent occlusion of the left anterior descending coronary artery (LAD) was produced in beagles. In seven dogs, serum EHDP was maintained at 10-15 μg/ml for 24 hours by continuous i.v. infusion, and seven control dogs were infused with saline. The Tc-99m PYP was infected 2 hours before sacrifice. EHDP-treated dogs showed a mild decrease (20%) in mean calcium content of infarcted myocardium (102.4 +/- 6.4 μg [+/- SEM] per gram wet weight [n = 51] vs 126.7 +/- 9.5 [n = 49] [p -3 ] [n = 46] vs 28.9 +/- 4.3 [n = 46] [p < 0.005]) and a marked decrease (65%) in infarct-to-normal ratio (6.1 +/- 0.9 [n = 6] vs 15.9 +/- 3.7 [n = 6] [p < 0.05]). Positive relationships were demonstrated between myocardial Tc-99m PYP and calcium levels in the EHDP-treated dogs (r = 0.69) and the control dogs (r = 0.77). Infarct size and regional myocardial blood flow changes were similar in the EHDP-treated and control dogs. The average grade (0-4+) of the Tc-99m PYP myocardial scintigrams for infarcts greater than 3.5 g was 2.4 +/- 0.2 for control dogs and 1.1 +/- 0.4 for EHDP-treated dogs (p < 0.05). Thus, EHDP infusion at the dose tested produced a mild decrease in calcium accumulation in canine infarcts; however, it produced a greater reduction in Tc-99m PYP uptake in the infarcts

  2. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  3. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  4. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  5. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  6. Clinical significance of technetium-99m stannous pyrophosphate myocardial scintigrams in patients with acute and old myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Ikuo; Eno, Shin; Takeuchi, Masaaki

    1987-08-01

    Seventy-five consecutive patients with acute (43) or old (32) myocardial infarction (AMI, OMI) have been examined by myocardial scintiscanning with technetium-99m stannous pyrophosphate (PYP). Using Parker's classification, the PYP scans were graded as positive in 56 % of the AMI patients; in restricting to the PYP scans obtained within the first 3 days after the onset, the positive rate was 86 %. Positive or negative PYP scans for the AMI patients were independent of maximum creatine phosphokinase and infarct site. For OMI patients, the PYP scans were positive in 41 %, with decreased left ventricular function being more common than those having negative PYP scans. In the group of positive scans, clinical manifestations tended to be remarkable, which were likely due to persistent cardiac ischemia during chronic stage. (Namekawa, K.).

  7. Scintigraphic visualization of myocardial infarcts in baboons using thallium-201 and technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Frick, M P; Ponto, R A; Pyle, R B; Yasmineh, W G; Loken, M K

    1978-01-01

    Four baboons with myocardial infarcts were evaluated using thallium-201 for myocardial imaging and /sup 99m/Tc pyrophosphate for infarct visualization. Scintiphotographic findings were compared with the size of myocardial infarcts calculated from measurements of the activity of MB isoenzymes of creatine kinase (CK-MB) in serum and in the myocardium at autopsy, as described by Sobel's method. Lack of thallium-201 accumulation was noted in left ventricular infarcts of 3 of the 4 baboons. These same areas localized /sup 99m/Tc pyrophosphate administered 24 to 30 h after infarction.

  8. Effect of methylprednisolone upon technetium-99m pyrophosphate assessment of myocardial necrosis in the canine countershock model

    International Nuclear Information System (INIS)

    Schneider, R.M.; Hayslett, J.P.; Downing, S.E.; Berger, H.J.; Donabedian, R.K.; Zaret, B.L.

    1977-01-01

    RRepeat DC countershock reproducibly results in myocardial necrosis in dogs. In this model, myocardial technetium-/sup 99m/ pyrophosphate (PYP) uptake correlates linearly with tissue creatine kinase depletion (r = -0.83). The effect of pretreatment with methylprednisolone (MP) was studied with PYP in 25 dogs. In myocardium damaged by countershock, 12 MP dogs had higher tissue radioactivity sample:normal (S:N) ratios than control (P < 0.05), suggesting increased tissue injury. However, by several other measures of tissue damage, the two groups did not differ. MP-elevated PYP S:N ratios were explained by reduced PYP activity in normal myocardium of MP dogs. Further experiments in 21 dogs revealed that renal PYP clearance, which correlated with glomerular filtration rate (GFR) as measured by creatinine clearance, was increased in MP dogs, resulting in accelerated urinary excretion of PYP (46.9 +- 3.6 vs 35.8 +- 2.4 percent injected dose in one hour, P < 0.01), and reduced blood PYP. Thus, MP does not modify countershock-induced myocardial injury. However, by increasing GFR, MP increased PYP excretion, resulting in lowered blood and normal zone myocardial PYP, thereby spuriously affecting myocardial PYP tissue uptake data

  9. High-risk angina patient: identification by clinical features, hospital course, electrocardiography, and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p < 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p < 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup, with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  10. High-risk angina patient. Identification by clinical features, hospital course, electrocardiography and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +/- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p less than 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p less than 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  11. Clinical usefulness of technetium-99m pyrophosphate and Tl-201 myocardial imaging for the estimation of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Akio; Sato, Akihiko; Miyakoda, Hiroyuki; Watanabe, Toshiya; Itatsu, Hidetaka; Ueda, Osamu; Sakurai, Kuniteru; Kawai, Naoki; Sotobata, Iwao

    1985-04-01

    A correlative study was performed between the infarct size estimated by either technetium-99 pyrophosphate (Tc-PYP) or Tl-201 myocardial imaging, and the cumulative total creatinine phosphokinase activity (..sigma..CPK) or left ventricular ejection fraction (LVEF) in 40 patients with acute myocardial infarction. Tc-PYP infarct area (TcIA) and mean Tl-201 uptake ratio (MUR) were calculated as indices of myocardial infarct size. LVEF was evaluated by first pass method using Tc-PYP in the acute phase of myocardial infraction. In 23 patients with anterior myocardial infarction, a significant correlation was shown between either TcIA or anterior-wall MUR and ..sigma..CPK (r=0.81 and r=-0.69, respectively) and also between either TcIA or anterior-wall MUR and LVEF (r=-0.84 and r=0.80, respectively). In 17 patients with inferior myocardial infarction without additional involvement of right ventricular wall, inferior-wall MUR correlated with ..sigma..CPK (r=-0.74). No statically significant correlation was shown between TcIA and ..sigma..CPK, and also between either TcIA or inferior-wall MUR and LVEF. In conclusion, the infarct size estimated with Tc-PYP or Tl-201 myocardial imaging could be a useful clinical indicator of the severity of acute myocardial infarction especially in anterior wall. (author).

  12. Technetium-99m pyrophosphate myocardial scintigraphy in the diagnosis of acute rheumatic carditis

    International Nuclear Information System (INIS)

    Malhotra, A.; Radhakrishnan, S.; Reddy, K.S.; Gopinath, P.G.; Bhatia, M.L.

    1989-01-01

    Rheumatic fever (RF) and rheumatic heart disease (RHD) are major health problems in India. The most difficult decision to make in such a setting is whether a patient of acute rheumatic fever has acute rheumatic carditis or not. Physical signs such as a new cardiac murmur, cardiac enlargement, congestive cardiac failure although quoted as pointers to carditis are non-specific specially if the attack is superimposed on pre-existing RHD. Any investigation which will provide an answer to this problem would be very welcome. sup(99m)Tc pyrophosphate (Tc PYP) is a very sensitive indicator of myocardial necrosis in acute myocardial infarction. A study to determine the usefulness of this technique in diagnosis of rheumatic carditis in patients with unequivocal clinical evidence of myocarditis was undertaken. Results are reported. (author). 14 refs

  13. Technetium-99m pyrophosphate scintigraphy for the detection of acute myocardial infarction. How useful is it

    International Nuclear Information System (INIS)

    Desai, A.G.; Berger, B.C.; Shin, Y.W.; Park, C.H.; Madsen, M.T.

    1985-01-01

    To evaluate the contribution of Tc-99m pyrophosphate scintigraphy (TPS) on the overall management of patients suspected of having acute myocardial infarction (AMI), hospital records of 58 consecutive patients who underwent TPS, were evaluated in depth. The results indicate that TPS was essential for the diagnosis of AMI in 16% of the patients. TPS was most rewarding in perioperative patients and in patients with borderline or uninterpretable electrocardiographic and enzyme changes. Also, in some cases, TPS was able to confirm or exclude the diagnosis of AMI prior to the confirmation by serial electrocardiograms (ECG) and serial enzyme changes. TPS was less rewarding in patients with clinically low index of suspicion for AMI. It may also be confusing in patients with high clinical likelihood of AMI and a history of prior myocardial infarction because of the possibility of persistently positive TPS in some of these patients. Considering the limitations of ECGs, the cardiac enzymes, and atypical clinical presentations in the patient population we evaluated, TPS appears to be fairly accurate when the scintigraphic findings are compared with the final diagnosis at the time of discharge from the hospital

  14. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  15. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  16. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  17. Infarct size in patients with acute myocardial infarction estimated by emission computed tomography with technetium-99m pyrophosphate. Relation to creatine phosphokinase release

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Jun-ichi; Onodera, Sokichi; Imura, Suguru; Marutani, Yoshiaki; Takahori, Takashi; Nasuhara, Koh-ichi

    1986-09-01

    To evaluate the usefulness of single photon emission computed tomography (SPECT) with technetium-99m-pyrophosphate (/sup 99m/Tc-PYP) for estimating infarct size, we compared SPECT data with maximum creatine phosphokinase values. Background threshold was established in a series of phantom experiments. When a 40 % cut-off was applied, the SPECT data most closely approximated actual phantom volumes. Therefore, the 40 % cut-off level was used in the present study. In 10 patients with acute myocardial infarction, planar /sup 99m/Tc-PYP myocardial scintigraphy and SPECT using a rotating gamma camera were performed two days after the initial myocardial infarction episode. The maximum creatine phosphokinase value (CPKmax) was also measured repeatedly following the episode. When the infarct size measured by SPECT using transaxial images and calculated by the pixel counts, it correlated very closely with CPKmax (r = 0.94). Most studies so far have reported that the CPKmax level reflects infarct size. We conclude that the infarct size as measured by /sup 99m/Tc-PYP SPECT closely approximates the actual infarct size, and that this method is useful to determine the severity of infarcts clinically. Among the 10 patients in this series, three of five with infarcts greater than 60 ml died of pump failure. Therefore, we may be able to predict prognosis after accumulating more such cases and improving the methodology.

  18. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  19. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  20. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  1. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  2. Lutetium pyrophosphates

    International Nuclear Information System (INIS)

    Dzhabishvili, N.A.; Davitashvili, E.G.; Orlovskij, V.P.; Kargareteli, L.N.

    1986-01-01

    Reaction between lutetium nitrate and pyrophosphates of sodium, potassium and ammonium in aqueous solution is studied, using the method of residual concentrations. New compounds are isolated, their composition and physicochemical properties are considered. Data on solubility in the systems at 25 deg C are given. All the hydrate pyrophosphates are roentgenoamorphous, they are crystallized only when heated. Thermal decomposition of lutetium pyrophosphate is investigated

  3. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    International Nuclear Information System (INIS)

    Kondo, M.; Yuzuki, Y.; Arai, H.; Shimizu, K.; Morikawa, M.; Shimono, Y.

    1987-01-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) in group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion

  4. Technetium and technetium alloys

    International Nuclear Information System (INIS)

    Ijdo, W.L.

    1993-10-01

    This report presents the results of a literature survey on technetium and technetium alloys. The literature has been searched through 1993. The survey was focused on technetium and (binary cubic) technetium alloys, but other important information on technetium has not been omitted from this survey. This report has been written with the aim to collect more information about phase systems which could be of importance in the transmutation process by neutrons of technetium. With the information presented in this report, it should be possible to select a suitable technetium alloy for further investigation regarding to the transmutation process. (orig.)

  5. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  6. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  7. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  8. Calcium Pyrophosphate Deposition (CPPD)

    Science.gov (United States)

    ... Patient / Caregiver Diseases & Conditions Calcium Pyrophosphate Deposition (CPPD) Calcium Pyrophosphate Deposition (CPPD) Fast Facts The risk of ... young people, too. Proper diagnosis depends on detecting calcium pyrophosphate crystals in the fluid of an affected ...

  9. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

    International Nuclear Information System (INIS)

    Giordano, A.; Meduri, G.; Calcagni, M.L.; Marozzi, P.; Ficola, U.; Vaccaro, A.; Rubini, G.; Attard, M.; Li Puma, M.; Ricci, R.; Corsello, S.

    1999-01-01

    The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201 Tl (74 MBq), 99m Tc-pertechnetate (74 MBq) and 99m Tc-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201 Tl and 99m Tc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99m Tc-tetrofosmin showed a higher parathyroid/background ratio than 201 Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99m Tc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%). (orig.)

  10. Fever of unknown origin and the value of gallium-67 and technetium-99/sup m/ for defining abnormality of the spleen: a case report

    International Nuclear Information System (INIS)

    Coopersmith, A.; Ritchey, A.K.; Zinkham, W.H.

    1975-01-01

    A three-year-old white female with acute promyelocytic leukemia developed persistent fever after successful induction-remission therapy; many large monilial abscesses were later found in the grossly enlarged spleen. Although the technetium/sup 99M/-sulfur colloid scan prior to splenectomy suggested only a slight abnormality of the spleen, the gallium-67 citrate scintigraph showed a marked increase in gallium accumulation. The disparate results of the scanning techniques utilized in this patient suggest that it may be necessary to use more than one type of radiopharmaceutical to define an enlarged spleen, as well as the pathological process responsible for its enlargement

  11. Technetium chemistry

    International Nuclear Information System (INIS)

    Burns, C.; Bryan, J.; Cotton, F.; Ott, K.; Kubas, G.; Haefner, S.; Barrera, J.; Hall, K.; Burrell, A.

    1996-01-01

    Technetium chemistry is a young and developing field. Despite the limited knowledge of its chemistry, technetium is the workhorse for nuclear medicine. Technetium is also a significant environmental concern because it is formed as a byproduct of nuclear weapons production and fission-power generators. Development of new technetium radio-pharmaceuticals and effective environmental control depends strongly upon knowledge of basic technetium chemistry. The authors performed research into the basic coordination and organometallic chemistry of technetium and used this knowledge to address nuclear medicine and environmental applications. This is the final report of a three-year Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL)

  12. Increased technetium uptake is not equivalent to muscle necrosis: scintigraphic, morphological and intramuscular pressure analyses of sore muscles after exercise

    Science.gov (United States)

    Crenshaw, A. G.; Friden, J.; Hargens, A. R.; Lang, G. H.; Thornell, L. E.

    1993-01-01

    A scintigraphic technique employing technetium pyrophosphate uptake was used to identify the area of skeletal muscle damage in the lower leg of four runners 24 h after an ultramarathon footrace (160 km). Most of the race had been run downhill which incorporated an extensive amount of eccentric work. Soreness was diffuse throughout the posterior region of the lower leg. In order to interpret what increased technetium uptake reflects and to express extreme endurance related damages, a biopsy was taken from the 3-D position of abnormal uptake. In addition, intramuscular pressures were determined in the deep posterior compartment. Scintigraphs revealed increased technetium pyrophosphate uptake in the medial portion of the gastrocnemius muscle. For 3698 fibres analysed, 33 fibres (1%) were necrotic, while a few other fibres were either atrophic or irregular shaped. A cluster of necrotic fibres occurred at the fascicular periphery for one subject and fibre type grouping occurred for another. Ultrastructural analysis revealed Z-line streaming near many capillaries and variously altered subsarcolemmal mitochondria including some with paracrystalline inclusions. The majority of the capillaries included thickened and irregular shaped endothelial cells. Intramuscular pressures of the deep posterior compartment were slightly elevated (12-15 mmHg) for three of the four subjects. Increased technetium uptake following extreme endurance running does not just reflect muscle necrosis but also subtle fibre abnormalities. Collectively, these pathological findings are attributed to relative ischaemia occurring during the race and during pre-race training, whereas, intramuscular pressure elevations associated with muscle soreness are attributed to mechanical stress caused by extensive eccentric work during the race.

  13. Technetium complexation by macrocyclic compounds

    International Nuclear Information System (INIS)

    Li Fan Yu.

    1983-01-01

    Research in nuclear medicine are directed towards the labelling of biological molecules, however, sup(99m)Tc does not show sufficient affinity for these molecules. The aim of this study was to evaluate the ability of macrocyclic compounds to bind strongly technetium in order to be used as complexation intermediate. The reducing agents used were a stannous complex and sodium dithionite. Cryptates and polyesters are not good complexing agents. They form two complexes: a 2:1 sandwich complex or 3:2 and a 1:1 complex. Cyclams are good complexing agents for technetium their complexations strength was determined by competition with pyrophosphate, gluconate and DTPA. Using the method of ligand exchange, the oxidation state of technetium in the Tc-cyclam complex was IV or V. They are 1:1 cationic complexes, the complex charge is +1. The biodistribution in rats of labelling solutions containing (cyclam 14 ane N 4 ) C 12 H 25 shows a good urinary excretion without intoxication risks [fr

  14. Usefulness of scintigraphy with Tc-99m labelled pyrophosphate in the diagnosis of acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Zolna, J; Strzelecki, A; Bartoszewski, A; Kardaszewicz, P; Salamon, A; Waligorski, M

    1982-01-01

    In 32 patients with transmural myocardial infarction scintigraphy was done using technetium-99m pyrophosphate as a marker. The test was performed between 4 and 7 day after infarction onset. In the group of 18 patients with anterior wall infarction in 2 cases no cumulation of the radioisotope was observed while in 14 cases the absorption of pyro-phosphate estimated to correspond to grade 2 or 3 in Parkey's scoring system was observed. In the group of 14 patients with inferior wall infarction in 4 cases pyrophosphate was not absorbed or only in a small degree. In the remaining patients radioactivity absorption was estimated to correspond to Parkey's grades 2 or 3. In both groups the radioacti-vity was absorbed more intensely in cases with high creatine phosphoki-nase values.

  15. Technetium in environmental waters

    International Nuclear Information System (INIS)

    Malcolme-Lawes, D.J.; Robb, P.; Warwick, P.

    1983-01-01

    A method for the determination of technetium in a sample of environmental water is described. Technetium, in the TcO 4 - form, is extracted from the sample onto an anion-exchange resin from which it is removed subsequently by washing with 4 M sodium thiocyanate solution. The eluted technetium-thiocyanate complex is then subjected to solvent extraction, where the technetium is further concentrated into butan-2-one. The organic phase is evaporated onto a planchette and the β activity due to the technetium determined by an anticoincidence Geiger counter. Detection limits of 0.5 ng of technetium-99 have been obtained for the counter and sample volumes in excess of 500 cm 3 can be analysed readily. The sorption of several technetium compounds onto soil from a variety of water types has also been investigated. Preliminary results are presented and the importance of the chemical form of technetium used in such studies is discussed briefly. (author)

  16. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  17. Technetium compounds

    International Nuclear Information System (INIS)

    Murphy, C.A. de; Ferro F, G.

    2003-01-01

    The first radiopharmaceuticals of 99m Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of 99m Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the 99m Tc, present a high recognition In vivo for specific receivers. (Author)

  18. Ressonância magnética vs cintilografia com pirofosfato marcado com tecnécio-99m para a detecção de necrose miocárdica perioperatória Magnetic resonance vs technetium-99m pyrophosphate scintigraphy in the detection of perioperative myocardial necrosis

    Directory of Open Access Journals (Sweden)

    Guilherme Urpia Monte

    2008-08-01

    Full Text Available FUNDAMENTO: O infarto do miocárdio perioperatório (IMPO é uma complicação da cirurgia de revascularização miocárdica (CRM com potencial impacto prognóstico. A cintilografia miocárdica (CM com pirofosfato marcado com tecnécio-99m é utilizada no diagnóstico de IMPO, mas demonstra limitada sensibilidade para lesões subendocárdicas. A ressonância magnética cardiovascular (RMC, por sua vez, detém alta acurácia para a detecção de necrose miocárdica. OBJETIVO: Comparar a RMC e a CM para a detecção de IMPO após CRM. MÉTODOS: Foram estudados 24 pacientes portadores de doença arterial coronária crônica, com a técnica de realce tardio pela RMC e com a CM, antes e depois da CRM, analisando-se o surgimento de áreas de necrose miocárdica perioperatória (IMPO. Mensuraram-se também marcadores bioquímicos de lesão miocárdica (CKMB e troponina I, antes e depois da cirurgia. RESULTADOS: Dezenove pacientes completaram o estudo. Desses, 6 (32% apresentaram IMPO à RMC, e 4 (21% à CM (p = NS. Dos 323 segmentos do ventrículo esquerdo avaliados, 17 (5,3% exibiram necrose perioperatória à RMC, e 7 (2,2% à CM (p = 0,013. Observou-se moderada concordância entre os métodos (kappa = 0,46, havendo divergência, quanto ao diagnóstico de IMPO, em 4 (21% casos, a maioria com pequenas áreas de necrose perioperatória à RMC, não visualizadas à CM. Em todos os casos com IMPO à RMC, houve elevação significativa de CKMB e troponina I. CONCLUSÃO: Houve moderada concordância diagnóstica entre os métodos para a detecção de IMPO, mas a RMC permitiu a visualização de pequenas áreas de necrose miocárdica perioperatória, não identificadas pela CM e associadas à elevação de marcadores bioquímicos de lesão miocárdica.BACKGROUND: Perioperative myocardial infarction (POMI is a complication of coronary artery bypass grafting (CABG with a potential prognostic impact. Technetium-99m pyrophosphate myocardial scintigraphy (MS is

  19. Nitrosyl complexes of technetium; Nitrosylkomplexe des Technetiums

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, Janine

    2016-09-22

    The presented thesis describes syntheses and characterization of novel technetium nitrosyl compounds with various ligand systems. The main focus is the synthesis of low-valent technetium nitrosyl complexes with cyclopentadienyl ligands. [German] Gegenstand der vorliegenden Arbeit ist die Synthese und Charakterisierung neuer Technetiumnitrosylverbindungen mit unterschiedlichen Ligandensystemen. Hauptaugenmerk wurde dabei auf die Darstellung niedervalenter Tc(NO)-Verbindungen mit Cyclopentadienyl-Liganden gelegt.

  20. Muscle necrosis in the extremities: evaluation with Tc-99m pyrophosphate scanning--a retrospective review

    International Nuclear Information System (INIS)

    Timmons, J.H.; Hartshorne, M.F.; Peters, V.J.; Cawthon, M.A.; Bauman, J.M.

    1988-01-01

    A retrospective review was done of 34 extremities studied between 1981 and 1985 with technetium-99m pyrophosphate scanning; 22 were subsequently amputated. Results of detailed pathologic examination or immediate postoperative examination of the resected extremity were available in 16 cases. In these cases, scanning had allowed correct prediction of the level of amputation and of the specific areas of muscle infarction in 13 cases. In the one case in which amputation was performed for infection rather than muscle necrosis, the lack of necrosis was correctly predicted with the scan. The limited results of this study indicate that the Tc-99m pyrophosphate scan allows the location of necrotic muscle to be predicted accurately and may therefore be a useful adjunct in determining the best level for ultimate amputation. Special caution is required in those cases in which muscle necrosis is due to acute causes (e.g., traumatic thrombosis) rather than chronic vascular disease

  1. Magnetic resonance Imaging (MRI) and technetium-99m-methoxyisonitrile (MIBI) scintigraphy to evaluate the abnormal parathyroid gland and PEIT efficacy for secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Wada, Akihiko; Sugihara, Masaki; Sugimura, Kazuro; Kuroda, Hiroyuki

    1999-01-01

    Percutaneous ethanol injection therapy (PEIT) of the abnormal parathyroid gland is an effective treatment in patients with chronic renal failure with dialysis that tends to be unresponsive to medication. To evaluate the efficacy of PEIT, we investigated the correlation between serum intact PTH (iPTH), and the findings of MR imaging and 99m Tc-MIBI scintigraphy. PEIT was performed 32 times in 24 patients with secondary hyperparathyroidism. Both MR imaging and MIBI scintigraphy were performed before and after PEIT. The detectability of parathyroid lesions was evaluated by MRI and MIBI scintigraphy with reference to ultrasound (B-mode) findings (as a standard) and the comparison of each treatment was done between imaging changes and serum iPTH levels. In the small parathyroid glands ( 99m Tc-MIBI scintigraphy. The reduction of high signal intensity area after PEIT on T2-weighted MR images is considered an useful therapeutic evaluation guideline than the reduction of MIBI accumulation on scintigraphy. (author)

  2. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  3. Photoaffinity labeling of undecaprenyl pyrophosphate synthetase with a farnesyl pyrophosphate analogue

    International Nuclear Information System (INIS)

    Baba, T.; Muth, J.; Allen, C.M.

    1985-01-01

    The prenyl transferase undecaprenyl pyrophosphate synthetase was partially purified from the cytosolic fraction of Escherichia coli. Its enzymic products were characterized as a family of cis-polyprenyl phosphates, which ranged in carbon number from C55 to C25. The enzyme is constituted of two subunits of approximately 30,000 molecular weight. A radiolabeled photolabile analogue of t,t-farnesyl pyrophosphate, [ 3 H]2-diazo-3-trifluoropropionyloxy geranyl pyrophosphate, was shown to label Lactobacillus plantarum and E. coli undecaprenyl pyrophosphate synthetase on UV irradiation in the presence of isopentenyl pyrophosphate and divalent cations. The only labeled polypeptide migrated on electrophoresis in a sodium dodecyl sulfate-polyacrylamide gel at a molecular weight of approximately 30,000. No protein was radiolabeled when the natural substrate, t,t-farnesyl pyrophosphate was included in the irradiation mixture. Irradiation in the presence of MgCl 2 without isopentenyl pyrophosphate gave less labeling of the polypeptide. Irradiation with only isopentenyl pyrophosphate gave little labeling of the polypeptide. When the enzyme was irradiated with 3H-photoprobe, [ 14 C]isopentenyl pyrophosphate, and MgCl 2 , the labeled polypeptide gave a ratio of 14 C/ 3 H that indicated the product must also bind to the enzyme on irradiation. These results demonstrate the ability to radiolabel the allylic pyrophosphate binding site and possibly product binding site of undecaprenyl pyrophosphate synthetase by a process which is favored when both cosubstrate and divalent cations are present

  4. Technetium compounds and their field of application

    International Nuclear Information System (INIS)

    Zaitseva, L.L.; Velichko, A.V.; Vinogradov, I.V.

    1988-02-01

    This chapter reviews the different applications of technetium and technetium compounds in catalysis, corrosion inhibition, superconductivity of technetium alloys, diagnostic techniques, radioisotope generators and radiopharmaceuticals. 649 refs [fr

  5. Chemistry of Technetium

    International Nuclear Information System (INIS)

    Omori, Takashi

    2001-01-01

    Since the late 1970's the coordination chemistry of technetium has been developed remarkably. The background of the development is obviously related to the use of technetium radiopharmaceuticals for diagnosis in nuclear medicine. Much attention has also been denoted to the chemical behavior of environmental 99 Tc released from reprocessing plants. This review covers the several aspects of technetium chemistry, including production of radioisotopes, analytical chemistry and coordination chemistry. In the analytical chemistry, separation of technetium, emphasizing chromatography and solvent extraction, is described together with spectrophotometric determination of technetium. In the coordination chemistry of technetium, a characteristic feature of the chemistry of Tc(V) complexes is referred from the view point of the formation of a wide variety of highly stable complexes containing the Tc=O or Tc≡N bond. Kinetic studies of the preparation of Tc(III) complexes using hexakis (thiourea) technetium(III) ion as a starting material are summarized, together with the base hydrolysis reactions of Tc(III), Tc(IV) and Tc(V) complexes. (author)

  6. Thermal conductivity of technetium

    International Nuclear Information System (INIS)

    Minato, K.; Serizawa, H.; Fukuda, K.

    1998-01-01

    The thermal diffusivity of technetium was measured on a disk sample of 5 mm in diameter and 1 mm in thickness by the laser flash method from room temperature to 1173 K, and the thermal conductivity was determined by the measured thermal diffusivity and density, and the reported specific heat capacity. The thermal diffusivity of technetium decreases with increasing temperature though it is almost constant above 600 K. The thermal conductivity of technetium shows a minimum around 400 K, above which the thermal conductivity increases with temperature. The electronic and phonon components of the thermal conductivity were evaluated approximately. The increase in the thermal conductivity of technetium with temperature is due to the increase in the electronic component. (orig.)

  7. Electrochemistry of technetium

    International Nuclear Information System (INIS)

    Russell, C.D.; Alabama Univ., Birmingham

    1982-01-01

    Recent work on the electrochemistry of technetium is reviewed, covering the period 1973-1980. Topics include polarographic studies of aqueous pertechnetate, coulometric studies of aqueous pertechnetate at mercury cathodes, and electrochemistry of pertechnetate at solid electrodes. A review is also given of electrochemistry of other technetium compounds, non-aqueous systems, chemical redox reactions, and substitution reactions. Consideration is also given to studies of electrochemistry at tracer concentrations, electrolytic syntheses, standard electrode potentials, and electroanalytical methods. (author)

  8. Familial pyrophosphate arthropathy. Occurrence and Crystal Identification.

    Science.gov (United States)

    Bjelle, A

    1981-01-01

    Hereditary pyrophosphate arthropathy has been observed in three Swedish families and in a few other caucasian populations. The inheritance is most probably autosomal dominant with a variable penetrance. The most severe cases have been found in homozygotes among isolates of immigrants in Slovakia and Chile. Studies on genetic and etio-pathogenetic factors in hereditary pyrophosphate arthropathy, and the utilization of new diagnostic techniques for crystal identification, are important approaches towards a further understanding of the disease.

  9. sup(99m)Tc-pyrophosphate scintiscanning in diagnostic orthopaedics

    International Nuclear Information System (INIS)

    Rauscher, W.

    1983-01-01

    To assess the findings of nuclear skeletal examinations, the pathological course of the disease must be known as far as possible. Pyrophosphate is the substance that causes bone accumulation while the metastable technetium is a high-intensity gamma source. Positive scintiscan findings are obtained in all processes with clear changes in the bone structure, e.g. all stages of osteomyelitis, articular processes of different genesis, inflammations, or activations of the bone metabolism. In these cases also processes of the articular cartilage and, partly, the soft tissue will be imaged. Terminated processes and purely degenerative changes, which are rare in clinical practice, will remain quiescent. Examinations after trauma or after surgery show a typical healing process. Scintiscanning is particularly useful for examinations of skeletal parts that are difficult to image by radiological methods; on the other hand, it does not yield additional information on the fit of an endoprothesis. Primary skeletal tumours can be diagnosed with sufficient accuracy only by means of quantitative methods. Nuclear methods, with their accurate information on the dynamics of the bone metabolism, often yield valuable additional information for the purposes of diagnosis, therapy, and prognosis. (orig./MG) [de

  10. Final Report Technetium Monitor

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2003-01-01

    The Hanford River Protection Project Waste Treatment Plant (WTP) is required by the current contract to remove radioactive technetium FR-om stored caustic nuclear waste solutions. The Savannah River Technology Center (SRTC) has worked with typical envelopes of these wastes to optimize the removal process. To support the studies, SRTC developed a rapid on-line remote analyzer to monitor technetium and rhenium levels in solutions as well as track other metals in the solutions through the process operations. Rhenium was used as a non-radioactive substitute for technetium in process development studies. The remote monitor was based on inductively coupled plasma emission spectroscopy (ICPES). Fiber optic cable and extended RF cabling removed the plasma source FR-om the spectrometer and instrument electronics

  11. Technetium in chemistry and nuclear medicine

    International Nuclear Information System (INIS)

    Deutsch, E.; Nicolini, M.; Wagner, H.N.

    1983-01-01

    This volume explores the potential of technetium radiopharmaceuticals in clinical nuclear medicine. The authors examine the capabilities of synthetic inorganic chemists to synthesize technetium radiopharmaceuticals and the specific requirements of the nuclear medicine practitioner. Sections cover the chemistry of technetium, the production of radiopharmaceuticals labeled with technetium, and the use of technetium radiopharmaceuticals in nuclear medicine

  12. Ceramics based on calcium pyrophosphate nanopowders

    Directory of Open Access Journals (Sweden)

    Tatiana V. Safronova

    2013-03-01

    Full Text Available Present work is aimed at the fabrication of resorbable bioceramics based on calcium pyrophosphate (CPP from the synthesized powders of amorphous hydrated calcium pyrophosphate (AHCPP. Amorphous hydratedcalcium pyrophosphate in the form of nanopowders was precipitated from Ca(NO3 2 and (NH4 4P2O7 solutions at room temperature in the presence of PO3– ions. Crystalline CPP powder was fabricated from AHCPP by its thermal decomposition at 600 °C and consisted of β- and α- phase. Small particles, with the size less than 200 nm, were formed promoting sintering of the ceramic material. The final sample, sintered at 900 °C, exhibits microstructure with submicron grains, apparent density of 87% of theoretical density (TD and demonstrates tensile strength of 70 MPa.

  13. Extraosseous uptake of 99sup(m)technetium methylene diphosphonate

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of 99 sup(m)technetium methylene diphosphate ( 99 sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of 99 sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  14. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  15. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate- 99m Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate- 99m Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders. Cardiac

  16. Fluorido complexes of technetium

    International Nuclear Information System (INIS)

    Mariappan Balasekaran, Samundeeswari

    2013-01-01

    Fluorine chemistry has received considerable interest during recent years due to its significant role in the life sciences, especially for drug development. Despite the great nuclear medicinal importance of the radioactive metal technetium in radiopharmaceuticals, its coordination chemistry with the fluorido ligand is by far less explored than that of other ligands. Up to now, only a few technetium fluorides are known. This thesis contains the synthesis, spectroscopic and structural characterization of novel technetium fluorides in the oxidation states ''+1'', ''+2'', ''+4'' and ''+6''. In the oxidation state ''+6'', the fluoridotechnetates were synthesized either from nitridotechnetic(VI) acid or from pertechnetate by using reducing agent and have been isolated as cesium or tetraethylammonium salts. The compounds were characterized spectroscopically and structurally. In the intermediate oxidation state ''+4'', hexafluoridotechnetate(IV) was known for long time and studied spectroscopically. This thesis reports novel and improved syntheses and solved the critical issues of early publications such as the color, some spectroscopic properties and the structure of this key compound. Single crystal analyses of alkali metal, ammonium and tetramethylammonium salts of hexafluoridotechnetate(IV) are presented. In aqueous alkaline solutions, the ammonium salt of hexafluoridotechnetate(IV) undergoes hydrolysis and forms an oxido-bridged dimeric complex. It is the first step hydrolysis product of hexafluoridotechnetate(IV) and was characterized by spectroscopic and crystallographic methods. Low-valent technetium fluorides with the metal in the oxidation states of ''+2'' or ''+1'' are almost unknown. A detailed description of the synthesis and characterization of pentafluoridonitrosyltechnetate(II) is presented. The complex was isolated as alkali metal salts, and spectroscopic as well as structural features of the complexes are presented. Different salts of the trans

  17. Anomalous properties of technetium clusters

    International Nuclear Information System (INIS)

    Kryuchkov, S.V.

    1985-01-01

    On the basis of critical evaluation of literature data in the field of chemistry of technetium cluster compounds with ligands of a weak field a conclusion is made on specific, ''anomalous'' properties of technetium cluster complexes which consist in an increased ability of the given element to the formation of a series of binuclear and multinuclear clusters, similar in composition and structure and easily transforming in each other. The majority of technetium clusters unlike similar compounds of other elements are paramagnetic with one unpaired electron on ''metallic'' MO of loosening type. All theoretical conceptions known today on the electronic structure of technetium clusters are considered. It is pointed out, that the best results in the explanation of ''anomalous'' properties of technetium clusters can be obtained in the framework of nonempirical methods of self-consistent field taking into account configuration interactions. It is also shown, that certain properties of technetium clusters can be explained on the basis of qualitative model of Coulomb repulsion of metal atoms in clusters. The conclusion is made, that technetium position in the Periodic table, as well as recently detected technetium property to the decrease of effective charge on its atoms during M-M bond formation promote a high ability of the element to cluster formation both with weak field ligands and with strong field one

  18. Technetium discharges into the environment

    International Nuclear Information System (INIS)

    Luykx, F.

    1986-01-01

    Technetium-99 is the most important technetium isotope released to the environment because of its long life and its relatively high fission yield. Its release to date, mainly as a result of nuclear fuel reprocessing, is estimated to be of the order of 1000 TBq. The quantity from nuclear weapons testing would only be some 10-15% of this value. (author)

  19. Fluorido complexes of technetium

    Energy Technology Data Exchange (ETDEWEB)

    Mariappan Balasekaran, Samundeeswari

    2013-07-04

    Fluorine chemistry has received considerable interest during recent years due to its significant role in the life sciences, especially for drug development. Despite the great nuclear medicinal importance of the radioactive metal technetium in radiopharmaceuticals, its coordination chemistry with the fluorido ligand is by far less explored than that of other ligands. Up to now, only a few technetium fluorides are known. This thesis contains the synthesis, spectroscopic and structural characterization of novel technetium fluorides in the oxidation states ''+1'', ''+2'', ''+4'' and ''+6''. In the oxidation state ''+6'', the fluoridotechnetates were synthesized either from nitridotechnetic(VI) acid or from pertechnetate by using reducing agent and have been isolated as cesium or tetraethylammonium salts. The compounds were characterized spectroscopically and structurally. In the intermediate oxidation state ''+4'', hexafluoridotechnetate(IV) was known for long time and studied spectroscopically. This thesis reports novel and improved syntheses and solved the critical issues of early publications such as the color, some spectroscopic properties and the structure of this key compound. Single crystal analyses of alkali metal, ammonium and tetramethylammonium salts of hexafluoridotechnetate(IV) are presented. In aqueous alkaline solutions, the ammonium salt of hexafluoridotechnetate(IV) undergoes hydrolysis and forms an oxido-bridged dimeric complex. It is the first step hydrolysis product of hexafluoridotechnetate(IV) and was characterized by spectroscopic and crystallographic methods. Low-valent technetium fluorides with the metal in the oxidation states of ''+2'' or ''+1'' are almost unknown. A detailed description of the synthesis and characterization of pentafluoridonitrosyltechnetate(II) is presented. The

  20. Technetium behavior and recovery in soil

    International Nuclear Information System (INIS)

    Meinken, G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated

  1. Technetium Behavior and Recovery in Soil

    Energy Technology Data Exchange (ETDEWEB)

    Meinken,G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated soils.

  2. Substitution reactions of technetium complexes

    International Nuclear Information System (INIS)

    Omori, T.

    1997-01-01

    Substitution reactions of a series of technetium complexes are considered in comparison with corresponding reactions of rhenium. Rhenium and technetium complexes are rather inert in substitution reactions, the latter are characterized by greater rate constants when they proceed according to dissociative mechanism. In rare cases when k Tc /k Re id little it is assumed that the reaction proceeds according to the associative mechanism. (author)

  3. A novel approach towards the synthesis of pyrophosphate analogues of farnesyl pyrophosphate

    NARCIS (Netherlands)

    Valentijn, A.R.P.M.; Berg, O. van den; Marel, G.A. van der; Cohen, L.H.; Boom, J.H. van

    1994-01-01

    The synthesis of two new analogues (i.e. 3 and 4) of farnesyl pyrophosphate (FPP) containing a phosphonophosphate and a phosphonophosphonate moiety was accomplished via the phosphonomorpholidate. The latter was easily obtained by treatment of a phosphonic chloride with morpholine.

  4. Jointscintigraphy with 99m Tc-pyrophosphate

    International Nuclear Information System (INIS)

    Mirtl, B.; Leb, G.; Klein, G.; Goebel, R.; Eber, O.

    1975-01-01

    Joint scintigraphy was performed in 85 patients suffering from a variety of rheumatic diseases, using a gamma camera and line scanner. Tc-pyrophosphate was the radio nuclide employed; it accumulates selectively in the juxta-articular parts of the bone. The method provides an objective demonstration of inflammatory and degenerative rheumatic joint changes. More over scintigraphic changes can be demonstrated in joint disease which is too early to be clinically apparent or before there are any corresponding changes in serological parameters. The method is useful both in the localisation and staging of disease, in the evaluation of treatment and as an objective control of clinical skills. (orig.) [de

  5. Chemistry and structure of technetium complexes

    International Nuclear Information System (INIS)

    Baldas, J.; Boas, J.F.; Bonnyman, J.; Williams, G.A.

    1983-01-01

    The structures of tris(2-aminobenzenethiolato) technetium(VI) and dichlorobis(diethyldithiocarbamato) thionitrosyltechnetium(V) have been determined by single crystal x-ray diffraction analysis. The preparation and chemistry of thiocyanato complexes of technetium have been investigated

  6. β-pyrophosphate: A potential biomaterial for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Anastasiou, A.D., E-mail: a.anastasiou@leeds.ac.uk [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Strafford, S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Posada-Estefan, O. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Thomson, C.L. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Hussain, S.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Cambridge Graphene Centre, Engineering Department, University of Cambridge, 9, JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom); Edwards, T.J. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Malinowski, M. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Hondow, N. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Metzger, N.K.; Brown, C.T.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Routledge, M.N. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Brown, A.P. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Duggal, M.S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Jha, A. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2017-06-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  7. β-pyrophosphate: A potential biomaterial for dental applications

    International Nuclear Information System (INIS)

    Anastasiou, A.D.; Strafford, S.; Posada-Estefan, O.; Thomson, C.L.; Hussain, S.A.; Edwards, T.J.; Malinowski, M.; Hondow, N.; Metzger, N.K.; Brown, C.T.A.; Routledge, M.N.; Brown, A.P.; Duggal, M.S.; Jha, A.

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  8. Technetium-aspirin molecule complexes

    International Nuclear Information System (INIS)

    El-Shahawy, A.S.; Mahfouz, R.M.; Aly, A.A.M.; El-Zohry, M.

    1993-01-01

    Technetium-aspirin and technetium-aspirin-like molecule complexes were prepared. The structure of N-acetylanthranilic acid (NAA) has been decided through CNDO calculations. The ionization potential and electron affinity of the NAA molecule as well as the charge densities were calculated. The electronic absorption spectra of Tc(V)-Asp and Tc(V)-ATS complexes have two characteristic absorption bands at 450 and 600 nm, but the Tc(V)-NAA spectrum has one characteristic band at 450 nm. As a comparative study, Mo-ATS complex was prepared and its electronic absorption spectrum is comparable with the Tc-ATS complex spectrum. (author)

  9. OSTEOPOROSIS IN CALCIUM PYROPHOSPHATE CRYSTAL DEPOSITION DISEASE

    Directory of Open Access Journals (Sweden)

    S A Vladimirov

    2013-01-01

    Full Text Available Objective: to study the incidence of osteoporosis (OP in patients with calcium pyrophosphate crystal deposition disease (CPCDD. Subjects and methods. Eighty patients with CPCDD were examined. Bone mineral density (BMD of the forearm, lumbar spine, and femoral neck was determined by dual-energy X-ray absorptiometry. Laboratory diagnosis involved determination of the blood levels of C-reactive protein, parathyroid hormone, calcium, magnesium, and phosphorus and the daily urinary excretion of calcium and phosphates. Results. The patients with OP were significantly older than those with normal BMD and osteopenia. Forearm bones were the most common isolated location of OP and osteopenia. Injuries in the history, traumatic fractures, and the intake of diuretics were somewhat more common in the patients diagnosed with OP. The incidence of hyperparathyroidism did not differ significantly in the groups.

  10. Calcium pyrophosphate deposition disease: clinical manifestations

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2012-01-01

    Full Text Available Calcium pyrophosphate deposition (CPPD disease is an arthropathy caused by calcium pyrophosphate dihydrate (CPP crystal deposits in articular tissues, most commonly fibrocartilage and hyaline cartilage. According to EULAR, four different clinical presentations can be observed: 1 asymptomatic CPPD; 2 osteoarthritis (OA with CPPD; 3 acute CPP crystal arthritis; 4 chronic CPP inflammatory crystal arthritis. Acute CPP crystal arthritis is characterized by sudden onset of pain, swelling and tenderness with overlying erythema, usually in a large joint, most often the knee, wrist, shoulder, and hip. Occasionally, ligaments, tendons, bursae, bone and the spine can be involved. CPPD of the atlanto-occipital joint (crowned dens syndrome can cause periodic acute cervico-occipital pain with fever, neck stiffness and laboratory inflammatory syndrome. Chronic inflammatory arthritis is characterized by joint swelling, morning stiffness, pain, and high ESR and CRP. The relationship between OA and CPPD is still unclear. The main problem is whether such crystals are directly involved in the pathogenesis of OA or if they are the result of joint degeneration. Diagnosis is based on evaluation of history and clinical features, conventional radiology, and synovial fluid examination. Non-polarized light microscopy should be used initially to screen for CPPD crystals based upon their characteristic morphology, and compensated polarized light microscopy, showing the crystals to be weakly positive birefringent, is recommended for definitive identification, although this last pattern only occurs in about 20% of samples. The main goals of CPPD therapy are control of the acute or chronic inflammatory reaction and prevention of further episodes.

  11. Methanophosphagen: Unique cyclic pyrophosphate isolated from Methanobacterium thermoautotrophicum

    OpenAIRE

    Kanodia, Sushila; Roberts, Mary Fedarko

    1983-01-01

    A unique cyclic pyrophosphate compound has been detected at 10-12 mM intracellular concentration in Methanobacterium thermoautotrophicum by in vivo31P NMR. This compound has been extracted from cells and purified by anion-exchange chromatography. Studies with 1H, 13C, and 31P NMR and fast-atom-bombardment mass spectrometry have identified it as 2,3-cyclopyrophosphoglycerate, an intramolecularly cyclized pyrophosphate of 2,3-diphosphoglycerate. Chemical degradation to 2,3-diphosphoglycerate an...

  12. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  13. Oscillator strengths for neutral technetium

    International Nuclear Information System (INIS)

    Garstang, R.H.

    1981-01-01

    Oscillator strengths have been calculated for most of the spectral lines of TcI which are of interest in the study of stars of spectral type S. Oscillator strengths have been computed for the corresponding transitions in MnI as a partial check of the technetium calculations

  14. Technetium migration in natural clays

    International Nuclear Information System (INIS)

    Luebke, Maria

    2015-01-01

    The present work was performed within the joint research project ''Retention of repository relevant radionuclides in argillaceous rocks and saline systems'' (contract no.: 02E10981), funded by the Federal Ministry for Economic Affairs and Energy (BMWi). The aim was to obtain first insights into the interaction of the long-lived fission product technetium and natural clay with regard to a repository for high-level nuclear waste. For this purpose Opalinus Clay from Mont Terri (northern Switzerland) was used as a reference material. The nuclide technetium-99 will contribute to the radiotoxicity of spent nuclear fuel for more than thousand years due to its long half-live. In case of a leakage of the storage vessels, the geochemistry of technetium is determined by its oxidation state, at which only the oxidation states +IV and +VII are relevant. Because of the high solubility and low affinity to sorption on surfaces of minerals, Tc(VII) is considered to be very mobile and thus the most hazardous species. The focuses of this study therefore are diffusion experiments with this mobile species and investigations of the effect of ferrous iron on the mobility and speciation of technetium.rnThe interaction of technetium and Opalinus Clay was studied in sorption and diffusion experiments varying several parameters (pH value, addition of reducing agents, effect of oxygen, diffusion pathways). In the course of this study spatially resolved investigations of the speciation have been performed on Opalinus Clay thin sections and bore cores for the first time. In addition to the speciation, further information regarding elemental distributions and crystalline phases near technetium enrichments were obtained. Supplementary investigations of powder samples allowed determining the molecular structure of technetium on the clay surface.rnBoth the combination of sorption experiments with spectroscopic investigations and the diffusion experiment exhibit a reduction of Tc

  15. Technetium accumulation, fate, and behavior in plants

    International Nuclear Information System (INIS)

    Cataldo, D.A.; Wildung, R.E.; Garland, T.R.

    1978-01-01

    Technetium, a product of the nuclear fuel cycle, is highly soluble in water and mobile in soils as the pertechnetate ion (TcO - 4 ). Soluble ions in soil have the potential for competing with nutrient ions for membrane carrier sites involved in ion uptake by plants. A study was, therefore, undertaken to determine the availability, toxicity, and mechanism of pertechnetate uptake by soybean (Glycine max cv. Williams). Technetium was effectively accumulated by plants at soil concentrations of 0.01 to 0.1 μg/g and in nutrient culture at levels as low as 0.02 pg/ml. Plants grown on soils containing technetium at levels below 0.1 μg/g effectively removed up to 90% of the technetium from soil. Minimal mobilization of technetium from vegetative tissues to the seed occurred during senescence. Chemical analyses indicated that the xylem-mobile form of technetium was TcO 4 - . The uptake rate of technetium by intact plants was multiphasic over the concentration range of 0.01 to 10μM; this suggests active uptake and a specificity for technetium in the root absorption process. Because of the efficiency of technetium accumulation and the probability of its chemical toxicity, competition kinetic studies were undertaken to identify possible nutrient analogs. Nutrients effective in reducing technetium uptake included the Mn 2+ , SO 4 2- , H 2 PO 4 - , and MoO 4 2- ions

  16. Emission tomography with sup(99m)Tc-pyrophosphate in the diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Uusitalo, A.; Virjo, A.

    1985-01-01

    Electrocardiograms (ECG) and enzyme criteria are usually used to confirm the diagnosis of acute myocardial infarction in the case of chest pain. However, ECG is not always diagnostic. Elevated enzyme values may be due to causes other than myocardial infarction. In uncertain cases, the ECG and enzyme criteria can be supplemented by emission tomography, performed with technetium pyrophosphate that will accumulate in the site of infarction. Twenty-nine patients with suspected acute myocardial infarction were studied with emission tomography. Of these 12 had acute transmural infarction. Both enzyme tests and ECG were diagnostic in only 7 of these 12 cases, 4 had positive enzyme tests but a nondiagnostic ECG and in one case neither enzymes nor ECG were diagnostic. In 11 patients the infarcted myocardial area was detected with emission tomography. Six patients had acute nontransmural infarction. Only 2 of these had positive emission tomography. The chest pain was not due to infarction in 11 patients. All these patients had negative emission tomography. The sensitivity of emission tomography was 92% and specificity 100% in transmural acute infarction. In nontransmural infarction the specificity was only 33%. Emission tomography is a valuable diagnostic tool. It may be the decisive method when ECG and enzymes are not diagnostic. Emissin tomography also shows the localization and size of the infarcted area in the myocardium. (orig.)

  17. Experience based on 60 observations of scintigraphic bone exploration using pyrophosphates

    International Nuclear Information System (INIS)

    Mienville, J.-C.

    1975-01-01

    5 to 15 millicuries of technetium 99m-labelled pyrophosphates are injected intraveinously. 3 to 5 hours later, when the blood activity has dropped, the bone uptake is sufficient to give a good scintigraphic image of the skeleton. The skeleton may be explored one segment at a time, using a scanning scintigraph or a scintillation camera, or the whole skeleton front and back may be examined much more quickly with a 'whole-body' device. A study of 60 observations shows the large number of hyperfixations revealed by isotopic explorations in rheumatological diseases. A hyperfixation was observed in almost all bone localities of osteophilic cancers, osteonecrosis, Paget's disease, infections osteo-arthritis and algoneurodystrophy. On the other hand the isotopic test was found to be negative or inefficient in arthroses, osteoporosis and local bone manifestations of Kahler's or Hodgkin's disease. Finally inflammatory arthritis was detectable by scintigraphy in about half the cases studied. In reality a hyperfixation reflects a local rise in the metabolic activity of the bone at the moment of the examination. As a result the scintigraphic images lack specificity. This factor must therefore be accounted for in the patient's records and isotopic results compared with those of clinical and para-clinical examinations [fr

  18. Significance of Tc-99m pyrophosphate accumulation in unstable angina

    International Nuclear Information System (INIS)

    Tange, Shoichi; Kondo, Chisato; Ohta, Yoshiko; Kusakabe, Kiyoko; Shigeta, Akiko; Uchida, Tatsuro; Sumiyoshi, Tetsuya; Kaneko, Noboru; Hosoda, Saichi

    1993-01-01

    Tc-99m pyrophosphate (PYP) and Tl-201 simultaneous dual energy single photon emission computed tomography (SPECT) were performed in 33 patients with clinically unstable angina. According to the presence or absence of PYP accumulation in the myocardium, the patients were classified as PYP (+) group (n=22) and PYP (-) group (n=11). Clinical features, types of unstable angina, ECG changes, and serial creatine kinase (CK) data were compared in the two groups. The 'new angina at rest' type of unstable angina was more significantly common in the PYP (+) group (16/22) than the PYP (-) group (2/11). The remaining 6 patients in the PYP (+) group and 2 patients in the PYP (-) group had 'angina of effort with changing pattern'. There was a significant difference in the occurrence of ST elevation and ST depression between the group: 59% in the PYP (+) group vs. 18% in the PYP (-) group for ST elevation and 23% in the PYP (+) group vs. 64% in the PYP (-) group for ST depression. The PYP (+) group showed significant improvement in ejection fraction in the stable state (57±12%) as compared with the unstable state (62±11%), although there was no difference between the stable and unstable state in the PYP (-) group. Although wall motion abnormality index (WMI) was poorer in the PYP (+) group than the PYP (-) group, it improved to the same degree as the PYP (-) group one month later. These data suggest that the area showing PYP (+) may reflect stunned myocardium and that Tc-99m PYP accumulation may correlate with clinical features of unstable angina. (N.K.)

  19. Sample preparation and characterization of technetium metal

    International Nuclear Information System (INIS)

    Minato, Kazuo; Serizawa, Hiroyuki; Fukuda, Kousaku; Itoh, Mitsuo

    1997-10-01

    Technetium-99 is a long-lived fission product with a half-life of about 2.1 x 10 5 years, which decays by β-emission. For the transmutation of 99 Tc, research on solid technetium was started. Technetium metal powder purchased was analyzed by X-ray diffraction, γ-ray spectrometry, and inductively coupled plasma-atomic emission spectrometry and -mass spectrometry. The lattice parameters obtained were agreed with the reported values. The metallic impurity was about 15 ppm, where aluminum and iron contributed mainly. No impurity nuclide with γ-emission was found. Using the technetium metal powder, button-, rod-, and disk-shaped samples of technetium metal were prepared by arc-melting technique. Thermal diffusivity of technetium metal was measured on a disk sample from room temperature to 1173 K by laser flash method. The thermal diffusivity decreased with increasing temperature though it was almost constant above 600 K. (author)

  20. Behaviour of technetium in marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Kirchmann, R.; Van Baelen, J.; Hurtger, C.; Cogneau, M.; Van der Ben, D.; Verthe, C.; Bouquegneau, J.M.

    1985-01-01

    Uptake and distribution of technetium were studied in several green (Acetabularia acetabulum, Boergesenia forbesii, Ulva lactuca) and brown (Ascophyllum nodosum, Fucus serratus, Fucus spiralis and Fucus vesiculosus) marine algae. Technetium was supplied to the algae as Tc-95m-pertechnetate. Under laboratory conditions, the algae were capable of accumulating technetium, with the exception, however, of Boergesenia, which showed concentration factors (C.F.) comprised between 0.28 and 0.71. The concentration of technetium-99 in Fucus spiralis, collected along the Belgian coast, was measured by a radiochemical procedure. The intracellular distribution of technetium was studied by differential centrifugation in Acetabularia and by the puncturing technique in Boergesenia. The chemical forms of technetium penetrated into the cells were investigated by selective chemical extractions, molecular sieving and thin layer chromatography

  1. Behaviour of technetium in marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Kirchmann, R.; Baelen, J. van; Hurtgen, C.; Cogneau, M.; Ben, D. van der; Verthe, C.; Bouquegneau, J.M.

    1986-01-01

    Uptake and distribution of technetium were studied in several green (Acetabularia acetabulum, Boergesenia forbesii, Ulva lactuca) and brown (Ascophyllum nodosum, Fucus serratus, Fucus spiralis and Fucus vesiculosus) marine algae. Technetium was supplied to the algae as Tc-95-pertechnetate. Under laboratory conditions, the algae were capable of accumulating technetium, with the exception, however, of Boergesenia, which showed concentration factors (C.F.) comprised between 0.28 and 0.71. The concentration of technetium-99 in Fucus spiralis, collected along the Belgian coast, was measured by a radiochemical procedure. The intracellular distribution of technetium was studied by differential centrifugation in Acetabularia and by the puncturing technique in Boergesenia. The chemical forms of technetium penetrated into the cells were investigated by selective chemical extractions, molecular sieving and thin layer chromatography. (author)

  2. Renal 99M-technetium dimercaptosuccinic acid scintigraphy

    International Nuclear Information System (INIS)

    Ajdinovic, B.; Jaukovic, L.; Jankovic, Z.; Krstic, Z.

    2004-01-01

    99m-Technetium dimercaptosuccinic acid (99mTc-DMSA) whose ligand was used as a radioprotective agent and as a chelating compound for metal poisoning was reported to be an excellent renal imaging agent. As 99mTc-DMSA concentrates actively in the proximal convoluted tubule, it gives an image functional renal mass. Its integrity is dependent upon several factors, predominently intrarenal blood flow and intact enzyme function.Considering low radiation dose delivered by 99mTc DMSA and wide pediatric use of this radiopharmaceutical we calculate abnormal findings incidence (%).Results of 592 99m Tc-DMSA renal scintigraphy (348 children), which were classified as: 1. normal, 2. probably normal, 3. equivocal, 4. probably abnormal, 5. abnormal, are presented.Normal results were found in 269 patients (45,4%), 25% of whom was normal and 75% probably normal. Equivocal findings were found in 47 patients (7,9%). Abnormal results were presented in 276 patients (82% abnormal, 18% probably abnormal).The highest abnormal findings incidence was found in patients with congenital anomaly (88%), calculosis (87%) and policystic renal disease (79,3%). The lowest abnormal findings percentage was present in patients with urinary tract infection (12,9%) and arterial hypertension (17,3%)The role 99mTc-DMSA renal scintigraphy in pathology is clear in pyelonephrifis, hydronephrotic kidneys, and pediatric disease (urinary tract infections, congenital anomalies) and is confirmed by our results. (authors)

  3. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  4. Extraosseous uptake of /sup 99/sup(m)technetium methylene diphosphonate. Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of /sup 99/sup(m)technetium methylene diphosphate (/sup 99/sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of /sup 99/sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  5. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P [Wisconsin Univ., Milwaukee (USA). Dept. of Radiology

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  6. PLUTONIUM PURIFICATION PROCESS EMPLOYING THORIUM PYROPHOSPHATE CARRIER

    Science.gov (United States)

    King, E.L.

    1959-04-28

    The separation and purification of plutonium from the radioactive elements of lower atomic weight is described. The process of this invention comprises forming a 0.5 to 2 M aqueous acidffc solution containing plutonium fons in the tetravalent state and elements with which it is normally contaminated in neutron irradiated uranium, treating the solution with a double thorium compound and a soluble pyrophosphate compound (Na/sub 4/P/sub 2/O/sub 7/) whereby a carrier precipitate of thorium A method is presented of reducing neptunium and - trite is advantageous since it destroys any hydrazine f so that they can be removed from solutions in which they are contained is described. In the carrier precipitation process for the separation of plutonium from uranium and fission products including zirconium and columbium, the precipitated blsmuth phosphate carries some zirconium, columbium, and uranium impurities. According to the invention such impurities can be complexed and removed by dissolving the contaminated carrier precipitate in 10M nitric acid, followed by addition of fluosilicic acid to about 1M, diluting the solution to about 1M in nitric acid, and then adding phosphoric acid to re-precipitate bismuth phosphate carrying plutonium.

  7. Technetium recovery from high alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  8. Method of producing radioactive technetium-99M

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    A chromatographic process of producing high purity and high yield radioactive Technetium-99m. A solution containing Molybdenum-99m and Technetium-99m is placed on a chromatographic column and eluted with a neutral solvent system comprising an organic solvent and from about 0.1 to less than about 10% of water or from about 1 to less than about 70% of a solvent selected from the group consisting of aliphatic alcohols having 1 to 6 carbon atoms. The eluted solvent system containing the Technetium-99m is then removed leaving the Technetium-99m as a dry, particulate residue

  9. Sorption of radionuclide technetium on minerals

    International Nuclear Information System (INIS)

    Li Min; Fan Xianhua; Wei Liansheng; Zhang Yingjie; Jiao Haiyang

    2004-01-01

    The study on adsorption behavior of technetium on antimonial minerals is performed in batch experiments and the influence of adsorption time, mineral granularity, solid-liquid ratio, initial concentration, pH value and reducing ion. On technetium adsorption are considered according to adsorption ratios of hepta valent and quadrivalent technetium on stibnite and antimony ocher, the results show that reduction of technetium from heptavelence to quadrivalence could improve adsorption ratios, which provide reference data for selecting buffer-backfill materials in high level rad waste deep geological diplosal. (author)

  10. Technetium removal from aqueous wastes

    International Nuclear Information System (INIS)

    Fletcher, P.A.; Jones, C.P.; Junkison, A.R.; Turner, A.D.; Kavanagh, P.R.

    1992-03-01

    The research discussed in this report has compared several ''state of the art'' techniques for the removal of traces of the radionuclide, technetium, from aqueous wastes. The techniques investigated were: electrochemical reduction to an insoluble oxide, electrochemical ion exchange, seeded ultrafiltration and chemical reduction followed by filtration. Each technique was examined using a simulant based upon the waste generated by the Enhanced Actinide Removal Plant (EARP) at Sellafield. The technique selected for further investigation was direct electrochemical reduction which offers an ideal route for the removal of technetium from the stream (DFs 10-100) and can be operated continuously with a low power consumption 25 kW for the waste generated by EARP. Cell designs for scale up have been suggested to treat the 1000m 3 of waste produced every day. Future work is proposed to investigate the simultaneous removal of other key radionuclides, such as ruthenium, plutonium and cobalt as well as scale up of the resulting process and to investigate the effect of these other radionuclides on the efficiency of the electrochemical reduction technique for the removal of technetium. Total development and full scale plant costs are estimated to be of the order of 5 pounds - 10M, with a time scale of 5 -8 years to realisation. (author)

  11. Recovery of technetium from nuclear fuel wastes

    International Nuclear Information System (INIS)

    Carlin, W.W.

    1975-01-01

    Technetium is removed from aqueous, acidic waste solutions. The acidic waste solution is mixed with a flocculant, e.g., an alkaline earth metal hydroxide or oxide, to precipitate certain fission products. Technetium remains in solution and in the resulting supernatant alkaline aqueous phase. The supernatant alkaline aqueous phase is made acidic and electrolyzed in an electrolytic cell under controlled cathodic potential conditions to deposit technetium on the cathode. Elemental technetium is removed from the cathode. Technetium is separated from other plated fission product metals by extraction from an alkaline solution with an organic extractant, such as pyridine, having affinity for technetium. Technetium is separated from the organic extractant by steam distillation and the resulting aqueous phase treated with ammoniacal reagent to precipitate technetium as ammonium pertechnetate. The precipitate may be acidified to form an aqueous acidic solution of fission product metal values and the solution electrolyzed in an electrolytic cell under controlled cathodic potential conditions and at a potential sufficiently negative to plate out from the solution those fission product metals desired. The metal deposit is stripped from the cathode and stored until its radioactivity has diminished. (U.S.)

  12. Process for producing radioactive technetium 99 m

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    Active aluminium oxide containing Molybdenum 99 and technetium 99 m is treated with a neutral solvent consisting of water, methylethylketone and ethanol. Technetium 99 m remains on the chromatographic material after drying, in the form of a dry powder. Other aliphatic alcohols can also be utilised. (DG) [de

  13. Chemistry of technetium in the environment

    International Nuclear Information System (INIS)

    McFadden, K.M.

    1980-08-01

    Technetium release to the environment may occur during separation and recovery of spent nuclear fuels, or in disposal of aqueous waste from nuclear facilities, hospitals, or other users. The chemistry and sources of technetium are reviewed as a basis for prediction of its behavior in the environment

  14. Sodium pyrophosphate enhances iron bioavailability from bouillon cubes fortified with ferric pyrophosphate.

    Science.gov (United States)

    Cercamondi, Colin I; Duchateau, Guus S M J E; Harika, Rajwinder K; van den Berg, Robin; Murray, Peter; Koppenol, Wieneke P; Zeder, Christophe; Zimmermann, Michael B; Moretti, Diego

    2016-08-01

    Fe fortification of centrally manufactured and frequently consumed condiments such as bouillon cubes could help prevent Fe deficiency in developing countries. However, Fe compounds that do not cause sensory changes in the fortified product, such as ferric pyrophosphate (FePP), exhibit low absorption in humans. Tetra sodium pyrophosphate (NaPP) can form soluble complexes with Fe, which could increase Fe bioavailability. Therefore, the aim of this study was to investigate Fe bioavailability from bouillon cubes fortified with either FePP only, FePP+NaPP, ferrous sulphate (FeSO4) only, or FeSO4+NaPP. We first conducted in vitro studies using a protocol of simulated digestion to assess the dialysable and ionic Fe, and the cellular ferritin response in a Caco-2 cell model. Second, Fe absorption from bouillon prepared from intrinsically labelled cubes (2·5 mg stable Fe isotopes/cube) was assessed in twenty-four Fe-deficient women, by measuring Fe incorporation into erythrocytes 2 weeks after consumption. Fe bioavailability in humans increased by 46 % (P<0·005) when comparing bouillons fortified with FePP only (4·4 %) and bouillons fortified with FePP+NaPP (6·4 %). Fe absorption from bouillons fortified with FeSO4 only and with FeSO4+NaPP was 33·8 and 27·8 %, respectively (NS). The outcome from the human study is in agreement with the dialysable Fe from the in vitro experiments. Our findings suggest that the addition of NaPP could be a promising strategy to increase Fe absorption from FePP-fortified bouillon cubes, and if confirmed by further research, for other fortified foods with complex food matrices as well.

  15. Study of sorption of technetium on pyrrhotine

    International Nuclear Information System (INIS)

    Shen Dong; Fan Xianhua; Su Xiguang; Zeng Jishu

    2001-01-01

    The sorption behaviors of technetium on pyrrhotine are studied with batch experiment and dilute sulfuric acid is used to dissolve the technetium adsorbed on pyrrhotine. Sorption and desorption experiment are performed under aerobic and anaerobic conditions (inert gas box). The results show that a significant sorption of technetium on pyrrhotine is found under aerobic and anaerobic conditions, and the sorption on the mineral is supposed to be due to the reduction of TcO 4 - to insoluble TcO 2 ·nH 2 O. Desorption process of the sorbed technetium into dilute sulfuric acid is found to be different under aerobic and anaerobic conditions. On addition of H 2 O 2 to the leach solution a sudden increase of the technetium concentration is observed

  16. sup(99m)Tc-pyrophosphate and /sup 201/Tl myocardial scintigrams in a patient with myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M.; Nishimura, T.; Shimoto, Y.; Fuzioka, S.; Kobayashi, K. (Shimada City Hospital, Shizuoka (Japan))

    1981-09-01

    Myocardial necrosis in acute myocarditis was investigated by scintigraphy. sup(99m)Tc-pyrophosphate (PYP) and /sup 201/TI myocardial scintigrams were obtained on a patient with acute myocarditis due to mycoplasma infection. sup(99m)Tc-PYP myocardial scintigrams in the acute stage demonstrated grade 2+ findings, which remained until the chronic stage. /sup 201/TI myocardial scintigrams in the acute stage revealed impaired perfusion restricted to the posterolateral wall, and this decrease continued through the chronic stage. It was concluded that both of sup(99m)Tc-PYP and /sup 201/TI myocardial scintigrams can reveal abnormality of acute myocarditis.

  17. Radiologic features of a pyrophosphate-like arthropathy associated with long-term dialysis

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Martel, W.; Menerey, K.; Fox, I.H.; Swartz, R.

    1987-01-01

    In a series of 28 long-term dialysis patients with musculoskeletal complaints, the radiologic findings in six cases resembled those occurring in the arthropathy of idiopathic calcium pyrophosphate dihydrate deposition (CPPD) disease. These findings included osteophytes, subchondral cysts, and cartilage loss in the metacarpophalangeal joints, patellofemoral joints, wrists, and shoulders. Chondrocalcinosis was present in three of the six cases. There were no significant differences in renal function or levels of serum calcium, phosphorus, iron, ferritin, aluminum, or parathormone between these patients and a control group matched for sex and age. Long-term dialysis may be associated with a metabolic arthritis similar to the arthritis which occurs in CPPD deposition disease. The etiology may include deposition of CPPD crystals, hydroxyapatite, or other calcium-containing substances in joints, or it may be related to a number of dialysis-induced metabolic abnormalities. (orig.)

  18. Radiologic features of a pyrophosphate-like arthropathy associated with long-term dialysis

    Energy Technology Data Exchange (ETDEWEB)

    Braunstein, E.M.; Martel, W.; Menerey, K.; Fox, I.H.; Swartz, R.

    1987-08-01

    In a series of 28 long-term dialysis patients with musculoskeletal complaints, the radiologic findings in six cases resembled those occurring in the arthropathy of idiopathic calcium pyrophosphate dihydrate deposition (CPPD) disease. These findings included osteophytes, subchondral cysts, and cartilage loss in the metacarpophalangeal joints, patellofemoral joints, wrists, and shoulders. Chondrocalcinosis was present in three of the six cases. There were no significant differences in renal function or levels of serum calcium, phosphorus, iron, ferritin, aluminum, or parathormone between these patients and a control group matched for sex and age. Long-term dialysis may be associated with a metabolic arthritis similar to the arthritis which occurs in CPPD deposition disease. The etiology may include deposition of CPPD crystals, hydroxyapatite, or other calcium-containing substances in joints, or it may be related to a number of dialysis-induced metabolic abnormalities.

  19. EPR investigations on technetium compounds

    International Nuclear Information System (INIS)

    Abram, U.; Munze, R.; Kirmse, R.; Stach, J.

    1986-01-01

    Stimulated by the widespread use of the isotope /sup 99m/Tc in the field of nuclear medicine, there has been a substantial growth of interest in the chemistry of this man-made element. A particular need emerges for analytical methods allowing solution investigations of coordination compounds of technetium with low substance use. Considering these facts, Electron Paramagnetic Resonance Spectroscopy (EPR) appears to be a very suitable method because only very small amounts of the compounds are needed (lower than 1 mg). The resulting spectra give information regarding the valence state, symmetry and bonding properties of the compounds under study

  20. Technetium removal: preliminary flowsheet options

    International Nuclear Information System (INIS)

    Eager, K.M.

    1995-01-01

    This document presents the results of a preliminary investigation into options for preliminary flowsheets for 99Tc removal from Hanford Site tank waste. A model is created to show the path of 99Tc through pretreatment to disposal. The Tank Waste Remediation (TWRS) flowsheet (Orme 1995) is used as a baseline. Ranges of important inputs to the model are developed, such as 99Tc inventory in the tanks and important splits through the TWRS flowsheet. Several technetium removal options are discussed along with sensitivities of the removal schemes to important model parameters

  1. Synthesis and thermal behavior of double copper and potassium pyrophosphate

    International Nuclear Information System (INIS)

    Ciopec, Mihaela; Muntean, Cornelia; Negrea, Adina; Lupa, Lavinia; Negrea, Petru; Barvinschi, Paul

    2009-01-01

    This paper presents the synthesis and thermal behavior of double copper and potassium pyrophosphate, which can be used as a PK fertilizer containing copper as micronutrient. In order to find the conditions for the synthesis of this compound from copper sulphate and potassium pyrophosphate, various Cu 2+ :P 2 O 7 4- molar ratios (0:1-2:1), various molar concentrations of the solutions (0.075; 0.1; 0.15 and 0.2 mol L -1 ) and various temperatures (25, 50, 75 and 100 o C) have been used. The solid product synthesized in optimum conditions for the separation of micronutrient copper from the reaction mass (Cu 2+ :P 2 O 7 4- molar ratio 1:1, concentration 0.1 mol L -1 ) was subjected to a complex study: chemical analysis, thermal analysis, energy dispersive X-ray spectroscopy, scanning electron microscopy and X-ray diffractometry. During heating up to 1000 o C, K 2 Cu 3 (P 2 O 7 ) 2 .3H 2 O loses the crystallization water; several transformations of the phosphates also take place: the decomposition of pyrophosphates to ortho-phosphates; the transformation of ortho-phosphates; the polymerization of a fraction of ortho-phosphates to amorphous phosphates with longer chains; the reorganization of ortho-phosphates and poly-phosphates to pyrophosphates and their crystallization. The decomposition mechanism was confirmed when using the X-ray diffraction patterns of the compound, thermally treated at several temperatures.

  2. Dissolution behaviour of ferric pyrophosphate and its mixtures with soluble pyrophosphates: Potential strategy for increasing iron bioavailability.

    Science.gov (United States)

    Tian, Tian; Blanco, Elena; Smoukov, Stoyan K; Velev, Orlin D; Velikov, Krassimir P

    2016-10-01

    Ferric pyrophosphate (FePP) is a widely used iron source in food fortification and in nutritional supplements, due to its white colour, that is very uncommon for insoluble Fe salts. Although its dissolution is an important determinant of Fe adsorption in human body, the solubility characteristics of FePP are complex and not well understood. This report is a study on the solubility of FePP as a function of pH and excess of pyrophosphate ions. FePP powder is sparingly soluble in the pH range of 3-6 but slightly soluble at pH8. In the presence of pyrophosphate ions the solubility of FePP strongly increases at pH 5-8.5 due to formation a soluble complex between Fe(III) and pyrophosphate ions, which leads to an 8-10-fold increase in the total ionic iron concentration. This finding is beneficial for enhancing iron bioavailability, which important for the design of fortified food, beverages, and nutraceutical products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Sorption of radioactive technetium on pyrrhotine

    International Nuclear Information System (INIS)

    Shen, D.; Fan, X.H.; Su, X.G.; Zeng, J.S.; Dong, Y.

    2002-01-01

    The sorption behavior of technetium on pyrrhotine was studied with batch experiments and diluted sulfuric acid (less than 2.88 mol/l) was used to dissolve the technetium adsorbed on pyrrhotine. A significant sorption of technetium on pyrrhotine was observed under aerobic and anaerobic conditions, and the sorption on the mineral was supposed to be due to the reduction of TcO 4 - to insoluble TcO 2 x nH 2 O. Sorbed technetium on the mineral could be desorbed by diluted sulfuric acid. The maximum desorption ratio under aerobic conditions was much higher than that of under anaerobic conditions, meanwhile, the desorption rates under anaerobic conditions were higher than that of under aerobic conditions in the initial stage of the experiments. (author)

  4. Technetium behaviour under deep geological conditions

    International Nuclear Information System (INIS)

    Kumata, M.; Vandergraaf, T.T.

    1993-01-01

    The migration behaviour of technetium under deep geological conditions was investigated by performing column tests using groundwater and altered granitic rock sampled from a fracture zone in a granitic pluton at a depth of about 250 m. The experiment was performed under a pressure of about 0.7 MPa in a controlled atmosphere glove box at the 240 m level of the Underground Research Laboratory (URL) near Pinawa, Manitoba, Canada. The technetium was strongly sorbed on the dark mafic minerals in the column. With the exception of a very small unretarded fraction that was eluted with the tritiated water, no further breakthrough of technetium was observed. This strong sorption of technetium on the mineral surface was caused by reduction of Tc(VII), probably to Tc(IV) even though the groundwater was only mildly reducing. (author) 5 figs., 4 tabs., 15 refs

  5. Radiation decomposition of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1979-01-01

    Technetium-99m radiopharmaceuticals are shown to be subject to autoradiation-induced decomposition, which results in increasing abundance of pertechnetate in the preparation. This autodecomposition is catalyzed by the presence of oxygen, although the removal of oxygen does not prevent its occurrence. The initial appearance of pertechnetate in the radiopharmaceutical is shown to be a function of the amount of radioactivity, the quantity of stannous ion used, and the ratio of /sup 99m/Tc to total technetium in the preparation

  6. Oxidative dehydrogenation of isobutane over a titanium pyrophosphate catalyst

    Directory of Open Access Journals (Sweden)

    IOAN-CEZAR MARCU

    2005-06-01

    Full Text Available The catalytic properties of titanium pyrophosphate in the oxidative dehydrogenation of isobutane to isobutylene were investigated in the 400 – 550 ºC temperature range. Asignificant change of the product distribution and of the apparent activation energy of the reactionwas observed at about 490 ºC. This phenomenon, already observed in the oxidative dehydrogenation of n-butane, has been interpreted by the existence of two reaction mechanisms depending upon the reaction temperature. Comparison with the n-butane reaction allowed different activation pathways for the activation of alkanes to be proposed. The catalytic properties of TiP2O7 in the oxidative dehydrogenation of isobutane was also compared to those obtained previously with several other pyrophosphates and TiP2O7 was found to be less active and selective for this reaction.

  7. Studying thermal dehydration of double nickel alkali metal pyrophosphates

    International Nuclear Information System (INIS)

    Bykanova, T.A.; Lavrov, A.V.; AN SSSR, Moscow. Inst. Obshchej i Neorganicheskoj Khimii)

    1978-01-01

    The methods of thermogravimetry, paper chromatography, infrared spectroscopy and X-ray phase analysis were used in studying the process of thermal dehydration of pyrophosphates of the M 2 Ni 3 (P 2 O 7 ) 2 xnH 2 O type (where n=6, 10; M=Na, K, Rb, Cs, NH 4 ). The dehydration of Cs 2 Ni 3 (P 2 O 7 ) 2 x10H 2 O proceeds in a single stage (endothermal effect at 210 deg C). The exothermal effects at 730 and 690 deg C correspond to the crystallization of the amorphous dehydration products. It has been established that binary pyrophosphates of nickel with alkali metals decompose when heated into Ni 3 (PO 4 ) 2 +MPO 4

  8. Quality control for a group of pyrophosphate-Sn kits

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Hernandez, I.; Leyva, R.; Turino, D.

    1994-01-01

    The quality control for a group of Pyrophosphate-Sn kits for labeling with 99 m Tc is carry out at the Isotope Center. A general discussion takes place about the instrumental techniques for the determination of the kit constituent such as ligands, Sn(II), water, etc, as well as the control table for the evaluation of the warranty time. (author). 5 refs, 4 figs

  9. β-pyrophosphate: A potential biomaterial for dental applications

    OpenAIRE

    Anastasiou, AD; Strafford, S; Posada-Estefan, O; Thomson, CL; Hussaein, SA; Edwards, TJ; Malinowski, M; Hondow, N; Metzger, NK; Brown, CTA; Routledge, MN; Brown, AP; Duggal, MS; Jha, A

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluat...

  10. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  11. Controllable Fabrication of Amorphous Co-Ni Pyrophosphates for Tuning Electrochemical Performance in Supercapacitors.

    Science.gov (United States)

    Chen, Chen; Zhang, Ning; He, Yulu; Liang, Bo; Ma, Renzhi; Liu, Xiaohe

    2016-09-07

    Incorporation of two transition metals offers an effective method to enhance the electrochemical performance in supercapacitors for transition metal compound based electrodes. However, such a configuration is seldom concerned in pyrophosphates. Here, amorphous phase Co-Ni pyrophosphates are fabricated as electrodes in supercapacitors. Through controllably adjusting the ratios of Co and Ni as well as the calcination temperature, the electrochemical performance can be tuned. An optimized amorphous Ni-Co pyrophosphate exhibits much higher specific capacitance than monometallic Ni and Co pyrophosphates and shows excellent cycling ability. When employing Ni-Co pyrophosphates as positive electrode and activated carbon as a negative electrode, the fabricated asymmetric supercapacitor cell exhibits favorable capacitance and cycling ability. This study provides facile methods to improve the transition metal pyrophosphate electrodes for efficient electrodes in electrochemical energy storage devices.

  12. Expression, crystallization and preliminary crystallographic study of octaprenyl pyrophosphate synthase from Helicobacter pylori

    International Nuclear Information System (INIS)

    Zhang, Jinyong; Zhang, Xiaoli; Mao, Xuhu; Zou, Quanming; Li, Defeng

    2011-01-01

    Octaprenyl pyrophosphate synthase from H. pylori has been expressed, purified and crystallized, and a diffraction data set was collected to 2.00 Å resolution. Octaprenyl pyrophosphate synthase (OPPs) is involved in the synthesis of the side chains of ubiquinone and menaquinone and catalyzes consecutive condensation reactions of farnesyl pyrophosphate with isopentenyl pyrophosphate to generate polyprenyl pyrophosphate and pyrophosphate. In order to investigate the roles played by OPPs in the metabolism of ubiquinone and menaquinone and the enzymatic mechanisms of these enzymes, analysis of the structure–function relationship of OPPs from Helicobacter pylori was initiated. The gene for OPPs was cloned, the protein was expressed, purified and crystallized and a diffraction data set was collected to 2.00 Å resolution. The crystals belonged to space group P4 1 2 1 2 or P4 3 2 1 2, with unit-cell parameters a = b = 109.33, c = 103.41 Å

  13. A pyrophosphate-responsive gadolinium(III) MRI contrast agent.

    Science.gov (United States)

    Surman, Andrew J; Bonnet, Célia S; Lowe, Mark P; Kenny, Gavin D; Bell, Jimmy D; Tóth, Eva; Vilar, Ramon

    2011-01-03

    This study shows that the relaxivity and optical properties of functionalised lanthanide-DTPA-bis-amide complexes (lanthanide=Gd(3+) and Eu(3+) , DTPA=diethylene triamine pentaacetic acid) can be successfully modulated by addition of specific anions, without direct Ln(3+) /anion coordination. Zinc(II)-dipicolylamine moieties, which are known to bind strongly to phosphates, were introduced in the amide "arms" of these ligands, and the interaction of the resulting Gd-Zn(2) complexes with a range of anions was screened by using indicator displacement assays (IDAs). Considerable selectivity for polyphosphorylated species (such as pyrophosphate and adenosine-5'-triphosphate (ATP)) over a range of other anions (including monophosphorylated anions) was apparent. In addition, we show that pyrophosphate modulates the relaxivity of the gadolinium(III) complex, this modulation being sufficiently large to be observed in imaging experiments. To establish the binding mode of the pyrophosphate and gain insight into the origin of the relaxometric modulation, a series of studies including UV/Vis and emission spectroscopy, luminescence lifetime measurements in H(2) O and D(2) O, (17) O and (31) P NMR spectroscopy and nuclear magnetic resonance dispersion (NMRD) studies were carried out. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    OpenAIRE

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    Inositol pyrophosphates are messenger molecules incorporating the energetic pyrophosphate bond. Although they have been implicated in diverse biologic processes, their physiologic functions remain enigmatic. We show that the catalytic activity of inositol hexakisphosphate kinase 2 (IP6K2), one of the principal enzymes generating the inositol pyrophosphate IP7 (5-diphosphoinositolpentakisphosphate), mediates cancer cell migration and tumor metastasis both in cell culture and intact mice. In th...

  15. Prognostic value of myocardial infarct size index, obtained with technetium-99m pyrophosphate and thallium-201 chloride scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Masami [Kanazawa Univ. (Japan). School of Medicine

    1982-02-01

    In order to determine the usefulness of nuclear cardiology methods in evaluating infarction size and in predicting subsequent mortality, the infarction size index was calculated and their left ventricular ejection fraction (LVEF) was measured for 136 patients with acute myocardial infarction, by means of sup(99m)Tc- and /sup 201/Tl-scintigraphy. Sensitivity of sup(99m)Tc-scintigraphy was 84% (of 44 cases). The hot sup(99m)Tc-areas were measured by planimetry only in anterior transmural infarctions. For 15 patients followed for 25 months on the average, hot areas were 13.8 +- 10.8 cm/sup 2/ in survivors and 31.7 +- 18.2 cm/sup 2/ in non-survivors. Both a doughnut pattern and persistent hot area in scintigraphs were signs of poor prognosis. Sensitivity of /sup 201/Tl-scintigraphy was 86% (of 95 cases). The extent of /sup 201/Tl perfusion defects was determined in three views by the average ratio of the length of perfusion defects to that of the left ventricle (LV). Interobserver correlation was high (r = 0.89). As the percent /sup 201/Tl defect index increased, the peak value of creatine phosphokinase, the grade of Peel index, incidence of congestion on initial chest X-ray, and LV aneurysma all gradually increased. In 48 patients followed for 23 months on the average after discharge, the incidence of congestive heart failure and mortality also increased with the larger degree of percent /sup 201/Tl defect index. In particular, the prognosis was poor in patients who had the percent /sup 201/Tl defect index larger than 40%. The LVEF, measured with a computerized multi-crystal gamma camera, was well correlated with that of contrast ventriculography (r = 0.92). The patients who had severe LV dysfunction and the LVEF less than 31% also showed poor prognosis.

  16. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1977-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate is described. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  17. The abdominal technetium scan (a decade of experience)

    International Nuclear Information System (INIS)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.; Karp, M.P.; Jewett, T.C. Jr.

    1982-01-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans, 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients

  18. Effect of applied potential on electrochemically reduced technetium diphosphonate radiopharmaceuticals

    International Nuclear Information System (INIS)

    Martin, J.L. Jr.; Heineman, W.R.; Deutsch, E.

    1987-01-01

    Technetium diphosphonate radiopharmaceuticals continue to play a major role in diagnostic nuclear medicine. Their ability to provide both structural and functional information provides a unique advantage which even the more recent imaging techniques cannot provide. The Tc-99m isotope possesses nuclear decay characteristics which allow maximum organ imaging following intravenous injection while delivering a minimal radiation burden to the patient. Due to the diphosphonate ligands' strong affinity for bone, Tc-99m diphosphonate complexes are routinely used for the determination of bone abnormalities such as cancerous tumors. Electrochemical reduction provides the additional parameter needed to increase the yield of a single component. This work presents the effect of varying the applied potential of the mercury pool electrode at selected pH values. The result of this variation in applied potential is tracked by anion exchange chromatographic separation based on the negatively charged Tc-diphosphonate complexes. These chromatograms are compared to those obtained by standard chemical reduction

  19. Linkable thiocarbamoylbenzamidines as ligands for bioconjugation of Rhenium and Technetium; Kopplungsfaehige Thiocarbamoylbenzamidine als Liganden zur Biokonjugation von Rhenium und Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Gomez, Juan Daniel

    2015-04-27

    Bioconjugation reactions with Rhenium and Technetium are of high importance for the development of novel radiopharmaceuticals for nuclear medicine. In this thesis the possibilities for bioconjugation using linkable Thiocarmbamoylbenzamidines as ligands for the complexation of Rhenium and Technetium were examined.

  20. Technetium in the geologic environment - a literature survey

    International Nuclear Information System (INIS)

    Torstenfelt, B.; Allard, B.; Andersson, K.; Olofsson, U.

    1981-07-01

    The authors present a literature survey of technetium, discussing, in particular, the oxidation states, the chemistry of technetium in connection with spent nuclear fuel storage, the sorption of technetium in rock, clay, soil and sea bottom sediments. (G.T.H.)

  1. Technetium compounds; Compuestos de tecnecio

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, C.A. de [Instituto Nacional de Ciencias Medicas y Nutricion Salvador Zubiran, Vasco de Quiroga 15, 14000 Tlalpan D.F. (Mexico); Ferro F, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The first radiopharmaceuticals of {sup 99m} Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of {sup 99m} Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the {sup 99m} Tc, present a high recognition In vivo for specific receivers. (Author)

  2. Technetium Immobilization Forms Literature Survey

    Energy Technology Data Exchange (ETDEWEB)

    Westsik, Joseph H.; Cantrell, Kirk J.; Serne, R. Jeffrey; Qafoku, Nikolla

    2014-05-01

    Of the many radionuclides and contaminants in the tank wastes stored at the Hanford site, technetium-99 (99Tc) is one of the most challenging to effectively immobilize in a waste form for ultimate disposal. Within the Hanford Tank Waste Treatment and Immobilization Plant (WTP), the Tc will partition between both the high-level waste (HLW) and low-activity waste (LAW) fractions of the tank waste. The HLW fraction will be converted to a glass waste form in the HLW vitrification facility and the LAW fraction will be converted to another glass waste form in the LAW vitrification facility. In both vitrification facilities, the Tc is incorporated into the glass waste form but a significant fraction of the Tc volatilizes at the high glass-melting temperatures and is captured in the off-gas treatment systems at both facilities. The aqueous off-gas condensate solution containing the volatilized Tc is recycled and is added to the LAW glass melter feed. This recycle process is effective in increasing the loading of Tc in the LAW glass but it also disproportionally increases the sulfur and halides in the LAW melter feed which increases both the amount of LAW glass and either the duration of the LAW vitrification mission or the required supplemental LAW treatment capacity.

  3. The molybdenum-technetium solar neutrino experiment

    International Nuclear Information System (INIS)

    Schroeder, N.C.; Wolfsberg, K.; Rokop, D.J.

    1991-01-01

    The authors are attempting to measure the time-averaged 8 B solar-neutrino flux over 10 Myr by measuring 98 Tc produced through the 98 Mo( nu ,e - ) reaction in a deeply buried molybdenum deposit. This will test the prediction of periodic mixing of the Sun's core over long time intervals. To separate technetium from 10,000-ton quantities of Henderson ore, the authors have taken advantage of the commercial processing of molybdenite. Technetium, volatilized during roasting of molybdenite to MoO 3 , was scrubbed from the gas stream and collected on anion exchange columns. After sample reduction and chemical separation and purification they measured technetium, as TcO 4 - , using negative thermal ionization mass spectrometry. Measurement of 99 Tc in spiked and 98 Tc in unspiked fractions from one sample gives an apparent solar neutrino production rate of 95.8 SNU. However, roaster memory probably invalidates this result

  4. Highvalent and organometallic technetium and rhenium compounds

    International Nuclear Information System (INIS)

    Oehlke, Elisabeth

    2010-01-01

    Diagnostic methods in nuclear medicine allow a detailed description of morphological organ structures and their function. The beta emitting isotope Tc-99 has optimal physical properties (140 keV gamma rays, half-life 6 h) and is therefore used for radiopharmaceuticals. The thesis is concerned with the search for new technetium complexes and their reproducible production. The (TcO3) core is of main interest. The second part of the thesis deals with organometallic technetium and rhenium complexes with carbonyl ligands and N-heterocyclic carbenes that show stability in aerobic aqueous solutions.

  5. Determination of technetium-99 from complex matrix

    International Nuclear Information System (INIS)

    Lixiong Wang; Lei Tang; Tongzai Yang; Yanqiu Yang; Liang Yang

    2013-01-01

    This paper reports an approach that can be used for efficient separation and determination of 99 Tc (as pertechnetate) after contamination of the environment by nuclear materials. The samples were decomposed by fusion in a mixture of potassium hydroxide and potassium nitrate. After fusion, technetium remains as the pertechnetate anion (TcO 4 - ). The technetium was isolated from the sample by technique combining solvent extraction, anion exchange, then, again, solvent extraction. After separation, 99 Tc was measured by isotope-dilution mass spectrometry with 97 Tc as spike. This method yielded nanogram detection limits for 99 Tc. (author)

  6. Determination of stability constants of pyrophosphate complexes. 2. Influence of divalent cations: the magnesium

    International Nuclear Information System (INIS)

    Courriere, P.; Guillemart, A.; Besnard, J.-C.

    1978-01-01

    The stability constants of the complexes of pyrophosphate with magnesium have been determined directly from the titration curves of sodium pyrophosphate in presence of Mg 2+ with hydrochloric acid by a least-square iterative method at the temperature of 25 0 C and at a ionic strength adjusted to unity [fr

  7. Pyrophosphate scan of the temporarily ischemized dog myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Veverkova, O.

    1981-12-01

    In 9 dogs a transient myocardial ischemia was provoked using complete occlusion of the ramus interventricularis anterior of the left coronary artery. The occlusion was removed after 5, 10 or 15 min. Four hrs after removal of the occlusion a scan of the myocardium was carried out using sup(99m)Tc-labelled pyrophosphate. In 7 out of 9 dogs under study the scan was markedly positive, in 2 dogs negative. ECG demonstrated ischemic changes practically in all dogs; the changes became normal after removal of the occlusion, namely in 5 to 35 min. The histological examination of the tissue demonstrated in all 9 dogs only a slight impairment of the myocardium.

  8. The pyrophosphate heart scintigram in children with progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Duska, F.; Nesvadba, Z.; Zdansky, P.; Novak, J.; Kubicek, J.; Kafka, P.; Vizda, J.; Mazurova, Y.; Karlova Univ., Hradec Kralove; Karlova Univ., Hradec Kralove

    1984-01-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index. (orig.) [de

  9. Pyrophosphate heart scintigram in children with progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Nesvadba, Z; Zdansky, P; Novak, J; Kubicek, J; Kafka, P; Vizda, J; Mazurova, Y

    1984-08-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index.

  10. Preoperative localization of parathyroid adenomas by technetium and thallium double-labeling scintigraphy. Difficulties linked to associated thyroid lesions

    International Nuclear Information System (INIS)

    Valensi, P.; Attali, J.R.; Sebaoun, J.; Bedig, G.; Paycha, F.; Tellier, P.; Vulpillat, M.; Sarfati, E.; Dubost, C.

    1989-01-01

    Technetium and thallium double-labeling scintigraphy with image subtraction was carried out on 63 patients suspected of having primary hyperparathyroidism, with or without thyroid involvement. Forty-four patients had a normal thyroid image with technetium. The positive foci located by double-labeling in patients who were to undergo surgery always coincided with parathyroid adenoma. In the 16 cases where the initial diagnosis of hyperparathyroidism was not substantiated, the double-labeling test was normal. Thus for these 44 patients, scintigraphy sensitivity was 75% and specificity was 100%. Nineteen patients had an abnormal thyroid image with technetium. In 7 cases, image subtraction following double-labeling yielded uninterpretable data. In 12 other patients, the positive foci located outside the thyroid by double-labeling coincided with a parathyroid adenoma, whereas this was true for only one patient whose positive foci were located inside the thyroid; a parathyroid adenoma was not detected preoperatively in 4 patients. This double-labeling test is thus useful in locating parathyroid adenomas when technetium scintigraphy of the thyroid is normal; when it is abnormal, double-labeling is advantageous only in cases of extrathyroid foci [fr

  11. Contributions to the coordination chemistry of technetium

    International Nuclear Information System (INIS)

    Lorenz, B.

    1989-08-01

    New types of technetium complexes were synthesized and analyzed by IR-, 1 H- and 99 Tc nmr as well as EPR spectra. They were tested for their potential catalytic activity in special organic reactions and their relevance to catalytic reactions, for example as intermediate compounds, is discussed in depth. 317 refs., 20 figs. (BBR) [de

  12. Electrochemical preparation of technetium hydroxyethylidene diphosphonate radiopharmaceuticals

    International Nuclear Information System (INIS)

    Scott, R.B.

    1984-01-01

    This work describes the liquid chromatographic and electrochemical analysis of electrogenerated technetium hydroxyethylidene diphosphonate (HEDP) complexes, and studies the effectiveness of the resulting bone imaging agents. Anion exchange High Performance Liquid Chromatography is used to separate components, and γ emission is used as the detection mode. The reaction mixtures were prepared at a series of reduction potentials and pH values, at both carrier added and no carrier added technetium levels. The results indicate that all three parameters affect the final complex composition to varying degrees. By optimizing the conditions, a preparation was made which results in a high percentage of a Tc-HEDP complex thought to be a very good home imager. This component was isolated chromatographically and injected into female Sprague-Dawley rats. Comparisons were run on the uptake for seven tissue types at two incubation times. Mercury and Reticulated Vitreous Carbon were used as the working electrode materials, and it is shown how reduced technetium will significantly alter the electrode characteristics, where a conditioned electrode will produce different complexes from those produced at fresh electrode material. By employing coulometric analysis as the preparation was reduced, an n value of 4 was calculated for a particular complex. This procedure involved tracking the radioactive technetium species carefully to account for all electrons used in the system. Finally, an electrochemical detection method for HEDP was explored, utilizing the property of mercury complexation. Anodic sweep Differential Pulse Polarography gives an analytical signal for HEDP at +0.250 V vs Ag/AgCl

  13. Synthesis and characterization of volatile technetium compound

    International Nuclear Information System (INIS)

    Childs, Bradley C.; Poineau, Frederic; Czerwinski, Ken R.

    2013-01-01

    Technetium-99 is an important fission (T 1/2 = 2.13.105 y) product of the nuclear industry. Technetium in its highest oxidation state (VII) is highly mobile and can represent a threat to the environment. There are over 55 million gallons of high level mixed waste located at the Hanford site. Waste tanks at the Hanford site contain Tc that could potentially leak, and in the context of management of technetium, a glass waste form was proposed to counteract the issue. In the process of synthesizing melt glass between the temperatures of 600°C and 1100°C, volatile technetium compounds were observed in the reaction tube. These compounds displayed characteristic colors based upon the reaction environments of either breathing air or nitrogen gas. A breathing air atmosphere produces a red compound that adheres to the walls of the reaction tube. An atmosphere of nitrogen gas produces a white compound that was observed on the walls of the reaction tube. (author)

  14. An introduction to technetium-99m generators

    International Nuclear Information System (INIS)

    Abrashkin, S.

    1984-02-01

    The role played by technetium-99m generators in diagnostic medicine, their physical and chemical fundamentals and their main technical characteristics are discussed. This report is intended as a general introduction to a group of reports which summarize the work done on the development and production of the generators, and research on the chemical and physical aspects of the generator systems

  15. Concentration of technetium by marine organisms

    International Nuclear Information System (INIS)

    Koyanagi, T.; Suzuki, Y.; Nakamura, R.; Nakahara, M.

    1990-01-01

    Accumulation and excretion of technetium by marine organisms were observed in radioisotope tracer experiments to determine concentration factors for estimating radiation dose to humans from radioactive pollution of marine environments. Marine fish, crustaceans, mollusks, echinoderms, and seaweeds were reared in sea water labeled with 95m Tc to observe uptake from sea water. The organisms were then transferred into unlabeled sea water for depuration experiments. Concentration factors were calculated from uptake and excretion rates. Also considered was the contribution of food-chain transfer of technetium, observed by administering labeled seaweeds to mollusks or echinoderms. Low accumulations were shown by fish, crustaceans, pelecypods and cephalopods, whereas high concentration factors were observed in gastropods and seaweeds. Species specificity or specific accumulation in special organs or tissues was not evident except in seaweed, where the difference was clearly species-associated. Relatively high rates of technetium retention were observed in the organisms administered labeled seaweed. The higher concentrations observed in gastropods, compared to those in pelecypods, were thought to result from different feed habits. The adaptability of some species as indicator organisms for monitoring 99 Tc in sea water was recognized, but the contribution of technetium to radiation dose was considered insignificant

  16. The origins of Technetium in the environment

    International Nuclear Information System (INIS)

    Scoppa, P.

    1986-01-01

    The origins of Technetium in the environment are briefly illustrated, taking into account its main sources represented by same plants of nuclear fuel cycle and by fallout fallowing nuclear explosion in atmosphere. An evaluation is also made of the TC-99 quantitees deriving from the production of nuclear power present in radioactive wastes before their final disposal

  17. Preparation of cerium doped calcium pyrophosphate: Study of luminescent behavior

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, I.B., E-mail: ivonne.berenice@gmail.com [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Roman-Lopez, J. [CONACYT Research Fellow-Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A.P. 70-543, 04510 México D.F., México (Mexico); Sosa, R. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico); Díaz-Góngora, J.A.I [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Azorín, J. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico)

    2016-05-15

    Thermoluminescent (TL) and photoluminescent (PL) band emissions of cerium doped calcium pyrophosphate (Ca{sub 2}O{sub 7}P{sub 2}:Ce{sup 3+}) were studied. Wet precipitation method was used to synthesize calcium pyrophosphate, doped with Ce{sup 3+} (1.0 at%) impurities, from orthophosphoric acid and calcium acetate, as raw materials. The effect of temperature annealing at 800 and 900 °C was investigated. X-Ray diffraction (XRD) and Scanning Electron Microscope (SEM) were used to characterize both as-precipitated and annealed powders samples. The PL emission spectrum of samples annealed at 900 °C displayed characteristics 5d–4f transitions of Ce{sup 3+} at 333 nm and 360 nm. TL measurements were carried out on as-precipitated and annealed samples from room temperature (RT) up to 350 °C. The TL results of annealed samples showed complex TL glow curves, a linear response in the absorbed dose range of 0.5–5 Gy and a good reproducibility after 10 cycles of irradiation-readout. The complex TL glow curves of annealed samples were analyzed by the methods of T{sub max}–T{sub Stop}, Initial Rise (IR) and Computational Glow-Curve Deconvolution (CGCD) assuming a General Order Kinetic (GOK).

  18. Technetium sorption by stibnite from natural water

    International Nuclear Information System (INIS)

    Peretroukhine, V.; Sergeant, C.; Deves, G.; Poulain, S.; Vesvres, M.H.; Thomas, B.; Simonoff, M.

    2006-01-01

    The sorption of technetium by powdered and polished mineral stibnite Sb 2 S 3 has been investigated in simulated and natural underground waters from the Meuse/Haute-Marne region (France). The sorption by powdered stibnite has been found to be complete under both aerobic and anaerobic conditions in batch experiments. The sorption rate is higher in the absence of oxygen than under aerobic condition. Increasing the temperature from 30 C to 60 C results in a rise of the sorption rate by 9.1 and 27 times under anaerobic and aerobic conditions, respectively. The observed differences in sorption kinetics in the presence and in absence of oxygen are explained by the interaction of oxygen with sulfide ion in aerobic conditions and by the reduction of technetium(VII) by iron(II) and by other impurities present in natural water and in the mineral, and by the subsequent sorption of Tc(IV) on stibnite under anaerobic conditions. The sorption on a polished mineral surface resulted in the formation of a technetium film, probably Tc 2 S 7 , with a thickness of 1-3 μg Tc/cm 2 pH 3-6 and 4-12 μg Tc/cm 2 at 9-12. The simultaneous formation of stibnite colloids with adsorbed technetium occurs at pH 9-12. The study of the technetium film on the mineral by proton induced X-ray emission analysis showed it to be at least one order of magnitude thinner on the SiO 2 impurities than on the main Sb 2 S 3 component and the iron impurities. (orig.)

  19. Investigating the pharmacodynamic and magnetic properties of pyrophosphate-bridged coordination complexes

    Science.gov (United States)

    Ikotun, Oluwatayo (Tayo) F.

    The multidentate nature of pyrophosphate makes it an attractive ligand for complexation of metal cations. The participation of pyrophosphate in a variety of biological pathways and its metal catalyzed hydrolysis has driven our investigation into its coordination chemistry. We have successfully synthesized a library of binuclear pyrophosphate bridge coordination complexes. The problem of pyrophosphate hydrolysis to phosphate in the presence of divalent metal ions was overcome by incorporating capping ligands such as 1,10-phenanthroline and 2,2'-bipyridine prior to the addition of the pyrophosphate. The magnetic properties of these complexes was investigated and magneto-structural analysis was conducted. The biological abundance of pyrophosphate and the success of metal based drugs such as cisplatin, prompted our investigation of the cytotoxic properties of M(II) pyrophosphate dimeric complexes (where M(II) is CoII, CuII, and NiII) in adriamycin resistant human ovarian cancer cells. Thess compounds were found to exhibit toxicity in the nanomolar to picomolar range. We conducted in vitro stability studies and the mechanism of cytoxicity was elucidated by performing DNA mobility and binding assays, enzyme inhibition assays, and in vitro oxidative stress studies.

  20. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  1. Technetium-labeled HM-PAO studies in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Smith, F.W.; Sharp, P.F.; Gemmell, H.; Evans, N.T.; MacDonald, A.F.

    1986-01-01

    Technetium-labeled hexamethyl-propyleneamineoxime (HM-PAO) is a promising radiopharmaceutical for the demonstration of cerebral blood flow. Twenty-four patients who had experienced either acute stroke (AS) or transient ischemic attack (TIA) were studied by x-ray CT and SPECT using technetium-labeled HM-PAO total of 26 studies. HM-PAO has a cerebral distribution similar to that of iodoamphetamine, but labeling with technetium allows good SPECT imaging on demand in any nuclear medicine department. In ten of the 16 patients who had experienced AS, findings on HM-PAO and CT studies correlated well. In six patients reduced cortical perfusion was detected on HM-PAO imaging, but only small infarcts in the internal capsule were seen on CT. In four of the eight patients who had experienced TIA, neither study revealed any abnormality. In the remaining four, areas of cortical underperfusion were seen on HM-PAO imaging, whereas the CT examination was normal. The findings in this study suggest that HM-PAO imaging is a more sensitive method for demonstrating the extent of cerebral underperfusion in cases of cerebrovascular accident

  2. Research program to investigate the fundamental chemistry of technetium

    Energy Technology Data Exchange (ETDEWEB)

    Shuh, David K.; Lukens, Wayne W.; Burns, Carol J.

    2003-12-19

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry that is necessary to address challenges to the safe, long-term remediation of high-level waste posed by this element. These challenges may be divided into two categories: unexpected behavior of technetium in high-level waste tanks at the Hanford and Savannah River Sites and the behavior of technetium in waste forms.

  3. Research program to investigate the fundamental chemistry of technetium

    International Nuclear Information System (INIS)

    Shuh, David K.; Lukens, Wayne W.; Burns, Carol J.

    2003-01-01

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry that is necessary to address challenges to the safe, long-term remediation of high-level waste posed by this element. These challenges may be divided into two categories: unexpected behavior of technetium in high-level waste tanks at the Hanford and Savannah River Sites and the behavior of technetium in waste forms

  4. X-ray electron investigation of technetium compounds

    International Nuclear Information System (INIS)

    Gerasimov, V.N.; Kryuchkov, S.V.; Kuzina, A.F.; Kulakov, V.M.; Pirozhkov, S.V.; Spitsyn, V.I.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii)

    1982-01-01

    Investigation results of a number of technetium compounds using the method of X-ray electron spectroscopy have been presented for the first time. Calculation of effective charge for compounds without Tc-Tc bond and cluster complexes with strong Tc-Tc bond is made. Strong interdependence of effective charge and properties of technetium clusters is shown. Binding energies for certain cluster complexes of technetium with halides are given

  5. Supplemental Report: Application of Emission Spectroscopy to Monitoring Technetium

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2000-01-01

    This report provides supplemental information to an earlier report BNF-98-003-0199, ''Evaluation of Emission Spectroscopy for the On-Line Analysis of Technetium''. In this report data is included from real Hanford samples as well as for solutions spiked with technetium. This supplemental work confirms the ability of ICP-ES to monitor technetium as it breaks through an ion exchange process

  6. Some aspects of the assay of technetium in environmental waters

    International Nuclear Information System (INIS)

    Robb, P.

    1983-09-01

    Technetium, as 99 Tc, was rapidly concentrated from large sample volumes (> 500 cm 3 ) by use of an anion exchange column after removal of ruthenium isotopes by precipitation. The bulk of the technetium can be removed from the resin by elution with sodium thiocyanate followed by further concentration by extraction with butan-2-one. Evaporation of solvent onto a planchette followed by measurement of emitted beta radiation can determine technetium levels. Method is capable of removing between 10 -15 and 10 -6 g of technetium from 500 cm 3 of water. (author)

  7. Sources and behavior of technetium in the environment

    International Nuclear Information System (INIS)

    Schulte, E.H.; Scoppa, P.

    1987-01-01

    Technetium is a man-made element produced in increasing amounts during the last decades. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is reviewed to evaluate its transfer and equilibrium distribution in aquatic and terrestrial ecosystems. Considerable effort has been expended in the last years in order to understand the biogeochemical processes responsible for the long-term behavior of technetium in the environment and its transfer through food chains as well as to identify critical pathways of the long-lived radioisotope Tc-99 from the environment to man. (Auth.)

  8. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Sandrock, D; Emrich, D [Goettingen Univ. (Germany). Abt. fuer Nuklearmedizin; Morguet, A J; Heim, A; Sold, G; Figulla, H R; Kreuzer, H [Goettingen Univ. (Germany). Abt. fuer Kardiologie und Pulmonologie

    1991-12-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG{sub 1} antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.).

  9. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    International Nuclear Information System (INIS)

    Munz, D.L.; Sandrock, D.; Emrich, D.; Morguet, A.J.; Heim, A.; Sold, G.; Figulla, H.R.; Kreuzer, H.

    1991-01-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG 1 antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.)

  10. Sorption behaviour of radioactive technetium in soils

    International Nuclear Information System (INIS)

    Xia Deying

    1996-01-01

    The sorption behaviour of technetium in different soils has been studied by batch experiments under aerobic conditions. The soil samples have been taken to study the characteristics and to derive the pH-Eh values. In addition, the activated carbon and reduced iron powder have been selected as additives to the JAERI sand according to the former research work, so that the technetium sorption behaviour in the artificial soils can be studied under similar conditions. The experimental results show that all these soil samples except for the gluey soil have a very small distribution coefficient for Tc, while the artificial soils have a very large distribution coefficient for Tc. Besides, for artificial soils, the distribution coefficient (R d ) values will become larger and larger when more additive is added and more contact time is allowed. The physico-chemical fixation processes and possible sorption modes have been discussed as well

  11. Geochemistry of natural technetium and plutonium

    International Nuclear Information System (INIS)

    Curtis, D.B.; Cappis, J.H.; Perrin, R.E.; Rokop, D.J.

    1987-01-01

    Technetium and plutonium in unprocessed nuclear reactor wastes are major concerns with regard to their containment in the geologic environment. Both nuclides have long half-lives; therefore, they will exist long after engineered barriers can be considered reliable. Consequently, strategies for the containment of these two elements depend on their retention in the geologic barrier until they have decayed to innocuous levels. Because these are the rarest elements in nature, there have been few direct observations of their geochemical behavior; predictions concerning their fate in the repository are based on properties that can be observed in the laboratory. The authors are attempting to complement the laboratory work by studying the geochemistry of natural plutonium and technetium. Ratios of anthropogenic to naturally occurring isotopes are discussed

  12. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  13. Study of ammonia synthesis using technetium catalysts

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Mikhajlenko, I.E.; Pokrovskaya, O.V.

    1982-01-01

    A study was made on catalytic properties of technetium in ammonia synthesis reaction. The preparation of technetium catalysts on ν-Al 2 O 3 , BaTiO 3 , BaO-ν-Al 2 O 3 substrates is described. The investigation of catalytic activity of catalysts was carried out at a pressure of 1 atm. in vertical reactor with volume rate of 15000 h - 1 in the temperature range of 350-425 deg. The amount of catalyst was 0.5-1 g, the volume- 0.5 ml, the size of granules- 2-3 mm. Rate constants of ammonia synthesis reaction were calculated. Seeming activation energies of the process have meanings wihtin the limits of 40-50 kcal/mol. It was shown that with increase in concentration of Tc on BaTiO 3 the catalytic activity rises in comparison with pure Tc. The reduction of catalytic activity with increase of metal content on Al 2 O 3 begins in the limits of 3.5-6.7% Tc/ν-Al 2 O 3 . The catalyst of 5.3% Tc/4.1% Ba/ν -Al 2 O 3 compound has the maximum activity. Technetium catalysts possess the stable catalytic activity and don't requre its reduction during several months

  14. Pyrophosphate as a central energy carrier in the hydrogen-producing extremely thermophilic Caldicellulosiruptor saccharolyticus

    NARCIS (Netherlands)

    Bielen, A.A.M.; Willquist, K.; Engman, J.; Oost, van der J.; Niel, van E.W.J.; Kengen, S.W.M.

    2010-01-01

    The role of inorganic pyrophosphate (PPi) as an energy carrier in the central metabolism of the extremely thermophilic bacterium Caldicellulosiruptor saccharolyticus was investigated. In agreement with its annotated genome sequence, cell extracts were shown to exhibit PPi-dependent

  15. Heterovalent Zr4+ - Cu2+ substitution in zirkonium pyrophosphate: From theoretical models to synthesis and utilization

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Šulcová, P.; Bosacka, M.; Filipek, E.; Vlček, Milan

    2015-01-01

    Roč. 35, č. 15 (2015), s. 4293-4305 ISSN 0955-2219 Institutional support: RVO:61389013 Keywords : zirconium pyrophosphate * cooper phosphates * thermal stability Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.933, year: 2015

  16. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease

    DEFF Research Database (Denmark)

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja

    2017-01-01

    OBJECTIVE: To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the ne...

  17. Pyrophosphate-Inhibition of Apatite Formation Studied by In Situ X-Ray Diffraction

    Directory of Open Access Journals (Sweden)

    Casper Jon Steenberg Ibsen

    2018-02-01

    Full Text Available The pathways to crystals are still under debate, especially for materials relevant to biomineralization, such as calcium phosphate apatite known from bone and teeth. Pyrophosphate is widely used in biology to control apatite formation since it is a potent inhibitor of apatite crystallization. The impacts of pyrophosphate on apatite formation and crystallization kinetics are, however, not fully understood. Therefore, we studied apatite crystallization in water by synchrotron in situ X-ray diffraction. Crystallization was conducted from calcium chloride (0.2 M and sodium phosphate (0.12 M at pH 12 where hydrogen phosphate is the dominant phosphate species and at 60 °C to allow the synchrotron measurements to be conducted in a timely fashion. Following the formation of an initial amorphous phase, needle shaped crystals formed that had an octacalcium phosphate-like composition, but were too small to display the full 3D periodic structure of octacalcium phosphate. At later growth stages the crystals became apatitic, as revealed by changes in the lattice constant and calcium content. Pyrophosphate strongly inhibited nucleation of apatite and increased the onset of crystallization from minute to hour time scales. Pyrophosphate also reduced the rate of growth. Furthermore, when the pyrophosphate concentration exceeded ~1% of the calcium concentration, the resultant crystals had reduced size anisotropy suggesting that pyrophosphate interacts in a site-specific manner with the formation of apatite crystals.

  18. Congenital Abnormalities

    Science.gov (United States)

    ... tube defects. However, there is also a genetic influence to this type of congenital anomaly. Unknown Causes The vast majority of congenital abnormalities have no known cause. This is particularly troubling for parents who plan to have more children, because there is no way to predict if ...

  19. Measurement and behaviour of technetium in fast reactor fuel reprocessing

    International Nuclear Information System (INIS)

    Ferguson, C.; Kyffin, T.W.

    1986-02-01

    A method is described for the spectrophotometric measurement of technetium in plant solutions from the reprocessing of fast reactor fuel. The technetium is selectively extracted using tri-iso-octylamine. After back extraction, thiocyanate is added, in the presence of tetrabutyl-ammonium hydroxide, to form the red hexa-thiocyanato anionic complex in a chloroform medium. The concentration of the technetium is then calculated from the spectrophotometric measurement of this complex. This method was applied to bulk samples, collected during a PFR fuel reprocessing campaign, to identify the main routes followed by technetium through the reprocessing plant. In order to understand the probable behaviour of technetium in the process plant streams, an investigation into the influence of plutonium IV nitrate on the extraction of Tc (VII) into 20%v/v tributyl phosphate/odourless kerosene solution from nitric acid solutions, was initiated. The results of this investigation, along with the known distribution coefficient for the extraction of the uranyl/technetium complex U0 2 (N0 3 )(Tc0 4 ).2TBP and the redox chemistry of technetium, are used to predict the probable behaviour of technetium in the process plant streams. This predicted behaviour is compared with the experimental results and reasonable agreement is obtained between experiment and theory, considering the history of the samples analysed. (author)

  20. Transfer of technetium from soil to paddy and upland rice

    International Nuclear Information System (INIS)

    Yanagisawa, Kei; Muramatsu, Yasuyuki

    1995-01-01

    Soil-plant transfer factors (concentration ratio between the plant and soil) of technetium in paddy and upland rice plants were obtained from laboratory experiments. The transfer factor is one of the most important parameters for environmental radiation dose assessment. Technetium tracer ( 95m TcO 4 - ) was added to the soil prior to rice cultivation. The transfer factor of technetium for the hulled grains (brown rice) of paddy rice (≤0.0002) was much lower than for that of upland rice (0.021). The transfer factors for both types of hulled grains were much lower than in the leaves. The technetium decontamination rate from hulled grains by polishing was 34%, the percentage of the weight decrease being 12%. The concentration of technetium in the soil solution collected from the paddy rice soil (flooded conditions) decreased rapidly with time due to its adsorption on the soil. In the upland rice soil (non-flooded) solution, the decrease in the technetium concentration was fairly slow. The low transfer factors for the paddy rice plants could be explained by the immobilization of technetium in the flooded soil. The oxidation-reduction potentials (Eh) in the flooded soil decreased rapidly with time. We conclude that technetium tracer added as TcO 4 - to flooded soil is readily transformed to an insoluble form (e.g.TcO 2 ) under the reducing conditions provided by flooding. (author)

  1. Accelerators for forming cationic technetium complexes useful as radiodiagnostic images

    International Nuclear Information System (INIS)

    Tweedle, M.F.

    1985-01-01

    This invention relates to compositions for making cationic radiodiagnostic agents and, in particular, to accelerator compounds for labelling such cationic radiodiagnostic agents, kits for preparing such 99m Tc-labelled cationic radiodiagnostic agents with technetium, and methods for labelling such cationic radiodiagnostic agents with technetium

  2. Search for technetium in natural tin metallurgical residues

    Energy Technology Data Exchange (ETDEWEB)

    Parker, C.W.

    1996-07-01

    Possible instability of baryons inside the nuclei might result in accumulation of rare isotopes in natural ores. In this respect, isotopes of technetium have certain advantages that can be useful in the search for technetium in nonradioactive ores by chemical methods. In this paper, we review the history of technetium research and discuss a new approach to the search for natural technetium associated with tin ores which appears to offer a rare possibility of discovering a smelting operation by-product such as flue dust, in which the volatile technetium heptoxide (Tc{sub 2}O{sub 7}), like rhenium heptoxide (Re{sub 2}O{sub 7}), would be expected to concentrate. Our concept of a search for technetium in these materials would be based on the assumption that traces of rhenium could occur in the ore and could be traced most easily by neutron activation of small samples. Such a procedure would confirm that an enrichment from the ore to the flue dust actually occurs with the rhenium and therefore should occur with technetium. Furthermore, this occurrence should identify the best location to search for technetium.

  3. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    International Nuclear Information System (INIS)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-01-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve

  4. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-08-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve.

  5. How good is technetium-99m mercaptoacetyltriglycine indirect cystography?

    International Nuclear Information System (INIS)

    Sadeleer, C. de; Boe, V. de; Keuppens, F.; Desprechins, B.; Verboven, M.; Piepsz, A.

    1994-01-01

    The aim of the present study was to estimate the sensitivity of indirect radionuclide cystography (IRC) performed with technetium-99m mercaptoacetyltriglycine (MAG3), in comparison with the micturition cystourethrography (MCUG) and direct radionuclide cystography (DRC), for the diagnosis of vesicoureteric reflux. Two groups of patients were selected: group I comprised 40 children who underwent IRC during the acute phase of urinary tract infection and an MCUG 6 weeks later; group II comprised 42 (other) children with known reflux, who underwent IRC and DRC during follow-up. Taking as the reference the total number of refluxing kidneys detected by means of any cystographic technique, 99m Tc-MAG3 ICR missed two-thirds of the refluxing kidneys. Most of the small refluxes were missed, but so too were 50% of the major refluxes. Taking as the reference 99m Tc dimercaptosuccinic acid (DMSA) scintigraphy, MCUG detected 91% of the patients with DMSA abnormalities on at least one kidney, DRC detected 95%, and IRC detected 46% and 43% respectively, in groups I and II. The use of 99m Tc-MAG3 IRC as the sole technique for the detection of vesicoureteric reflux gives rise to an unacceptable number of false-negative results. (orig.)

  6. A method for the determination of technetium in environmental waters

    International Nuclear Information System (INIS)

    Robb, P.; Warwick, P.; Malcolme-Lawes, D.J.

    1985-01-01

    A method is described which can be used to determine technetium-99 levels in a range of water types. Ruthenium isotopes which may interfere in the analysis are removed from the sample by precipitation before concentration of pertechnetate onto an ion-exchange column. Other nuclides can be removed from the column using NaOH before elution of the technetium using NaSCN. The technetium in the NaSNC eluent can then be extracted into butan-2-one which can be evaporated onto a planchette. Technetium-99m is used as a yield tracer and after this has decayed away to negligible levels. The amount of technetium on the planchette can be determined by measuring the rate of beta radiation emission from the final concentrate. (author)

  7. Corrosion and antifouling characteristics of technetium 99 in seawater

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Strekalov, P.V.; Balakhovskij, O.A.; Mikhajlovskij, Yu.N.

    1982-01-01

    The results are presented of studying the corrosive and antifouling properties of metallic technetium-99 in the Barents Sea and the Sea of Japan. Foil of 99 Tc glued on acrylic plastic served as a sample. High corrosion resistance and antifouling properties exhibited by 99 Tc in seawater point to favorable prospects of further studies aimed at development of new methods for protection against corrosion and fouling of metallic structures and parts with the use of technetium. The antifouling properties of technetium would evidently be used most efficiently when coating materials of high corrosion resistance to seawater (titanium, stainless steels, special alloys, etc.) with layers of technetium. The use of technetium for coating low-alloyed or carbon steels employed in seawater is yet problematic

  8. The labeling of kanamycin using radionuclide of technetium as an agent for early detection of infectious deseases

    International Nuclear Information System (INIS)

    Widyasari, E.; Zainuddin, M.N.; Nuraeni, W.

    2013-01-01

    Infectious diseases are still the leading cause of death in the world. Early detection and determination of the exact location of infection and accurate imaging through the use of nuclear techniques can facilitate treatment. Antibiotics radioactive labeled compound otherwise be able to be a solution to distinguish between infective and non-infective inflammatory. Kanamycin is an antibiotic used for the treatment of infections where other drugs such as penicillin and several other drugs that are less potent infection can not be used. This study aims to determine the optimum labeling conditions of 99m Tc-kanamycin in order to obtain high labeling efficiency. Kanamycin has successfully labeled with technetium-99m through indirect labeling method using pyrophosphate as a co-ligand. Labeling efficiency and determination of radiochemical purity of these compounds simultaneously determined by ascending paper chromatography using Whatman paper 3 as the stationary phase, and acetone as the mobile phase to separate the radiochemical impurities in the form of 99m Tc-pertechnetate; while impurities in the form of reduced 99m Tc-separated by using the stationary phase ITLC-SG and 0.5 N NaOH as mobile phase. The result showed that the optimal labeling conditions was obtained on the use of 6 mg kanamycin, 300 mg SnCl2, 1.5 mg of Na-pyrophosphate, and pH = 6. The incubation time of 0-30 min at room temperature, provide labeling efficiency of 96.54 ± 0.36%. The successful of kanamycin labeling with high efficiency makes 99m Tc-kanamycin potentially to be used as a radiopharmaceutical for the early detection of infectious diseases. (author)

  9. Biosynthesis of monoterpenes: Stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to camphane and isocamphane monoterpenes

    International Nuclear Information System (INIS)

    Croteau, R.; Gershenzon, J.; Wheeler, C.J.; Satterwhite, D.M.

    1990-01-01

    The conversion of geranyl pyrophosphate to (+)-bornyl pyrophosphate and (+)-camphene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this bound intermediate. In the case of (-)-bornyl pyrophosphate and (-)-camphene, isomerization of the substrate to the (+)-(3S)-linalyl intermediate precedes cyclization. The geranyl and linalyl precursors were shown to be mutually competitive substrates (inhibitors) of the relevant cyclization enzymes isolated from Salvia officinalis (sage) and Tanacetum vulgare (tansy) by the mixed substrate analysis method, demonstrating that isomerization and cyclization take place at the same active site. Incubation of partially purified enzyme preparations with (3R)-[1Z-3H]linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate gave rise to double-labeled (+)-bornyl pyrophosphate and (+)-camphene, whereas incubation of enzyme preparations catalyzing the antipodal cyclizations with (3S)-[1Z-3H]-linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate yielded double-labeled (-)-bornyl pyrophosphate and (-)-camphene. Each product was then transformed to the corresponding (+)- or (-)-camphor without change in the 3H:14C isotope ratio, and the location of the tritium label was deduced in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogen of the derived ketone. The finding that the 1Z-3H of the linalyl precursor was positioned at the endo-alpha-hydrogen of the corresponding camphor in all cases, coupled to the previously demonstrated retention of configuration at C1 of the geranyl substrate in these transformations, confirmed the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate and the cyclization of the latter via the anti,endo- conformer

  10. Technetium migration in natural clays; Migration von Technetium in natuerlichem Tongestein

    Energy Technology Data Exchange (ETDEWEB)

    Luebke, Maria

    2015-10-01

    The present work was performed within the joint research project ''Retention of repository relevant radionuclides in argillaceous rocks and saline systems'' (contract no.: 02E10981), funded by the Federal Ministry for Economic Affairs and Energy (BMWi). The aim was to obtain first insights into the interaction of the long-lived fission product technetium and natural clay with regard to a repository for high-level nuclear waste. For this purpose Opalinus Clay from Mont Terri (northern Switzerland) was used as a reference material. The nuclide technetium-99 will contribute to the radiotoxicity of spent nuclear fuel for more than thousand years due to its long half-live. In case of a leakage of the storage vessels, the geochemistry of technetium is determined by its oxidation state, at which only the oxidation states +IV and +VII are relevant. Because of the high solubility and low affinity to sorption on surfaces of minerals, Tc(VII) is considered to be very mobile and thus the most hazardous species. The focuses of this study therefore are diffusion experiments with this mobile species and investigations of the effect of ferrous iron on the mobility and speciation of technetium.rnThe interaction of technetium and Opalinus Clay was studied in sorption and diffusion experiments varying several parameters (pH value, addition of reducing agents, effect of oxygen, diffusion pathways). In the course of this study spatially resolved investigations of the speciation have been performed on Opalinus Clay thin sections and bore cores for the first time. In addition to the speciation, further information regarding elemental distributions and crystalline phases near technetium enrichments were obtained. Supplementary investigations of powder samples allowed determining the molecular structure of technetium on the clay surface.rnBoth the combination of sorption experiments with spectroscopic investigations and the diffusion experiment exhibit a reduction of Tc

  11. Evolution of technetium speciation in reducing grout

    Energy Technology Data Exchange (ETDEWEB)

    Lukens, Wayne W.; Bucher, Jerome J.; Shuh, David K.; Edelstein,Norman M.

    2003-11-24

    Cementitious waste forms (CWFs) are an important component of the strategy to immobilize high-level nuclear waste resulting from plutonium production by the U.S. Department of Energy (DOE). Technetium (99Tc) is an abundant fission product of particular concern in CWFs due to the high solubility and mobility of pertechnetate, TcO4-, the stable form of technetium in aerobic environments. CWFs can more effectively immobilize 99Tc if they contain additives that reduce mobile TcO4- to immobile Tc(IV) species. Leaching of 99Tc from reducing CWFs that contain Tc(IV) is much slower than for CWFs containing TcO4-. Previous X-ray absorption fine structure (XAFS) studies showed that the Tc(IV) species were oxidized to TcO4- in reducing grout samples prepared on a laboratory scale. Whether the oxidizer was atmospheric O2 or NO3- in the waste simulant was not determined. In actual CWFs, rapid oxidation of Tc(IV) by NO3- would be a concern, whereas oxidation by atmospheric O2 would be of less concern due to the slow diffusion and reaction of O2 with the reducing CWF. To address this uncertainty, two series of reducing grouts were prepared using TcO4- containing waste simulants with and without NO3-. In the first series of samples, the TcO4- was completely reduced using Na2S, and the samples were placed in containers that permitted O2 diffusion. In these samples, all of the technetium was initially present as aTc(IV) sulfide compound, TcSx, which was characterized using extended X-ray absorption fine structure (EXAFS) spectroscopy, and is likely Tc2S7. The TcSx initially present in the grout samples was steadily oxidized over 4 years. In the second series of samples, all of the TcO4- was not initially reduced, and the grout samples were placed in airtight containers. In these samples, the remaining TcO4- continued to be reduced as the samples aged, presumably due to the presence of reducing blast furnace slag. When samples in the second series were exposed to atmosphere, the

  12. Behavior of technetium in paddy soils

    International Nuclear Information System (INIS)

    Yanagisawa, K.; Muramatsu, Y.; Ban-Nai, T.

    1997-01-01

    In order to understand the chemical form of soluble technetium in paddy soil and its availability to a rice plant, soil incubation and uptake experiments have been carried out using 95m Tc as a tracer. The chemical form of the soluble Tc was observed by gel chromatography and found not to be pertechnetate, but rather to be associated with soluble organic matter. An uptake experiment with rice seedlings using nutrient solution showed that this Tc-organic matter complex was less available than pertechnetate. (author)

  13. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity.

    Science.gov (United States)

    Sakr, Tamer M; Khedr, Mohammed A; Rashed, Hassan M; Mohamed, Maged E

    2018-02-23

    l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl) phosphinyl) butyric acid ammonium salt (AHPB)), which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs), this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS), in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium ( 99m Tc)-phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  14. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity

    Directory of Open Access Journals (Sweden)

    Tamer M. Sakr

    2018-02-01

    Full Text Available l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl phosphinyl butyric acid ammonium salt (AHPB, which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs, this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS, in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium (99mTc–phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  15. Control of technetium at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Saraceno, A.J.

    1981-01-01

    Technetium-99 entered the gaseous diffusion complex as a volatile impurity in recycled uranium that was fed to the Paducah Gaseous Diffusion Plant. Subsequently, it entered the Oak Ridge and Portsmouth cascades as an impurity in Paducah product feed. Most of the technetium was adsorbed on cascade equipment in increasingly high concentrations as it moved up the cascade. Since the low energy beta radiation produced by technetium cannot penetrate cascade equipment, it presents no significant hazard to workers as long as it remains inside of equipment. However, when equipment that contains high concentrations of technetium is opened for maintenance or change-out, precautions are taken to ensure worker safety. Traps containing activated alumina are used at the plant vent streams to limit radioactive emissions as far as possible. Annual vent stream emissions have been well below DOE limits. To allow continued compliance, other potential trapping agents have been tested. Several that limit emissions more effectively than activated alumina have been found. Other traps containing magnesium fluoride are used in the upper cascade to reduce the technetium concentration. Waste solutions from decontamination can also contain technetium. These solutions must either be stored for controlled discharge or treated to remove the technetium. To allow the latter, an ion exchange facility is being installed for operation by the end of FY-1982. Liquid discharges at Portsmouth have usually been less than 5% of the DOE imposed limits

  16. Research program to investigate the fundamental chemistry of technetium

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, David A.; Buechele, Andrew C.; Lukens, Wayne W.; Muller, Isabelle S.; Shuh, David K.; Pegg, Ian L.

    2007-10-12

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry necessary to address challenges to the safe, long-term disposal of high-level nuclear waste posed by this element. The primary issues examined during the course of this project were the behavior of technetium and its surrogate rhenium during waste vitrification and glass corrosion. Since the redox behavior of technetium can play a large role in determining its volatility, one goal of this research was to better understand the behavior of technetium in glass as a function of the redox potential of the glass melt. In addition, the behavior of rhenium was examined, since rhenium is commonly used as a surrogate for technetium in waste vitrification studies. A number of glasses similar to Hanford Low Activity Waste (LAW) glasses were prepared under controlled atmospheres. The redox state of the glass was determined from the Fe(II)/Fe(III) ratio in the cooled glass, and the speciation of technetium and rhenium was determined by x-ray absorption fine structure (XAFS) spectroscopy. The behavior of rhenium and technetium during glass alteration was also examined using the vapor hydration test (VHT).

  17. The Role of Thiamine Pyrophosphate in Prevention of Cisplatin Ototoxicity in an Animal Model

    Directory of Open Access Journals (Sweden)

    Ozan Kuduban

    2013-01-01

    Full Text Available Objective. The aim of this study was to evaluate the effectiveness of thiamine pyrophosphate against cisplatin-induced ototoxicity in guinea pigs. Materials and Methods. Healthy guinea pigs (n=18 were randomly divided into three groups. Group 1 (n=6 received an intraperitoneal injection of saline solution and cisplatin for 7 days, group 2 (n=6 received an intraperitoneal injection of thiamine pyrophosphate and cisplatin for 7 days, and group 3 (n=6 received only intraperitoneal injection of saline for 7 days. The animals in all groups were sacrificed under anesthesia, and their cochleas were harvested for morphological and biochemical observations. Results. In group 1, receiving only cisplatin, cochlear glutathione concentrations, superoxide dismutase, and glutathione peroxidase activities significantly decreased (P<0.05 and malondialdehyde concentrations significantly increased (P<0.05 compared to the control group. In group 2, receiving thiamine pyrophosphate and cisplatin, the concentrations of enzymes were near those of the control group. Microscopic examination showed that outer hair cells, spiral ganglion cells, and stria vascularis were preserved in group 2. Conclusion. Systemic administration of thiamine pyrophosphate yielded statistically significant protection to the cochlea of guinea pigs from cisplatin toxicity. Further experimental animal studies are essential to determine the appropriate indications of thiamine pyrophosphate before clinical use.

  18. Technetium-99 in the Irish marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Smith, V.; Fegan, M.; Pollard, D.; Long, S.; Hayden, E.; Ryan, T.P

    2001-07-01

    Technetium-99 activity concentrations in seawater and biota from Irish coastal waters are presented. Time series measurements of {sup 99}Tc in seawater and Fucus vesiculosus from the western Irish Sea show that activity concentrations have increased in line with the increase in discharges of {sup 99}Tc from Sellafield. The peak in activity concentrations in both seawater and Fucus vesiculosus occurred in 1997 approximately two years after the peak in {sup 99}Tc discharges. The highest activity concentration recorded in Fucus vesiculosus showed a 29-fold increase over the mean concentration for the period 1988-1993. Technetium-99 activity concentrations were measured in fish, lobsters, prawns, mussels and oysters landed at major fishing ports on the east and northeast coasts of Ireland between 1996 and 1998. Concentration factors for {sup 99}Tc in the brown seaweed Fucus vesiculosus and certain species of fish, crustaceans and molluscs from the Irish Sea were estimated. In general, these concentration factors were higher than those in the literature which were derived from laboratory studies, but agreed well with values which were based on field studies. The mean committed effective doses to Irish typical and heavy seafood consumers due to {sup 99}Tc in the period 1996-1998 were 0.061 and 0.24 {mu}Sv, respectively.

  19. Research Program to Investigate the Fundamental Chemistry of Technetium

    International Nuclear Information System (INIS)

    Edelstein, Norman M.; Burns, Carol J.; Shuh, David D.; Lukens, Wayne

    2000-01-01

    Technetium (99Tc, half-life = 2.13x105 years, b-emitter) is one of the radionuclides of major concern for nuclear waste disposal. This concern is due to the long half-life of 99Tc, the ease with which pertechnetate, TcO4 -, migrates in the geosphere, and the corresponding regulatory considerations. The problem of mobility of pertechnetate in the environment is compounded by the fact that pertechnetate is the thermodynamically stable form of technetium in aerobic environments. These two factors present challenges for the safe, long term immobilization of technetium in waste forms. Because of the stability of pertechnetate, technetium has been assumed to exist as pertechnetate in the aqueous phase of nuclear waste tanks. However, recent studies indicate that a significant fraction of the technetium is in a different chemical form. This program addresses the fundamental solution chemistry of technetium in the waste tank environment, and in a second part, the stability of technetium in various waste forms. The chemistry of this element will be studied in aqueous solutions at high pH, with various added salts such as nitrate, nitrite, and organic complexants, and as a function of radiation dose, to determine whether radiolysis effects can reduce TcO4 -. A separate facet of this research is the search for chemical forms of technetium that may be thermodynamically and/or kinetically stable and may be incorporated in various waste forms for long term storage. This phase of the program will address the problem of the possible oxidation of lower valent technetium species in various waste form matrices and the subsequent leaching of the highly soluble TcO4 -

  20. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  1. Method of stably radiolabeling antibodies with technetium and rhenium

    International Nuclear Information System (INIS)

    Paik, C.H.; Reba, R.C.; Eckelman, W.C.

    1987-01-01

    A method is described for labeling antibodies or antibody fragments with radionuclides of technetium or rhenium to obtain stable labeling, comprising: reacting a reduced radioisotope of technetium or rhenium with an antibody or antibody fragment, or a diethylenetriaminepentaacetic acid conjugated antibody or antibody fragment, in the presence of free or carrier-bound diethylenetriaminepentaacetic acid (DTPA). The amount of DTPA is sufficient to substantially completely inhibit binding of the reduced technetium or rhenium to nonstable binding sites of the antibody or antibody fragment, or the DTPA-conjugated antibody or antibody fragment. The resultant stably labeled antibody or antibody fragment, or DTPA[conjugated antibody or antibody fragment is recovered

  2. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy

    International Nuclear Information System (INIS)

    Bodenant, V.

    1998-01-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  3. Ion exchange removal of technetium from salt solutions

    International Nuclear Information System (INIS)

    Walker, D.D.

    1983-01-01

    Ion exchange methods for removing technetium from waste salt solutions have been investigated by the Savannah River Laboratory (SRL). These experiments have shown: Commercially available anion exchange resins show high selectivity and capacity for technetium. In column runs, 150 column volumes of salt solution were passed through an ion exchange column before 50% 99 Tc breakthrough was reached. The technetium can be eluted from the resin with nitric acid. Reducing resins (containing borohydride) work well in simple hydroxide solutions, but not in simulated salt solutions. A mercarbide resin showed a very high selectivity for Tc, but did not work well in column operation

  4. Central role of pyrophosphate in acellular cementum formation.

    Directory of Open Access Journals (Sweden)

    Brian L Foster

    Full Text Available Inorganic pyrophosphate (PP(i is a physiologic inhibitor of hydroxyapatite mineral precipitation involved in regulating mineralized tissue development and pathologic calcification. Local levels of PP(i are controlled by antagonistic functions of factors that decrease PP(i and promote mineralization (tissue-nonspecific alkaline phosphatase, Alpl/TNAP, and those that increase local PP(i and restrict mineralization (progressive ankylosis protein, ANK; ectonucleotide pyrophosphatase phosphodiesterase-1, NPP1. The cementum enveloping the tooth root is essential for tooth function by providing attachment to the surrounding bone via the nonmineralized periodontal ligament. At present, the developmental regulation of cementum remains poorly understood, hampering efforts for regeneration. To elucidate the role of PP(i in cementum formation, we analyzed root development in knock-out ((-/- mice featuring PP(i dysregulation.Excess PP(i in the Alpl(-/- mouse inhibited cementum formation, causing root detachment consistent with premature tooth loss in the human condition hypophosphatasia, though cementoblast phenotype was unperturbed. Deficient PP(i in both Ank and Enpp1(-/- mice significantly increased cementum apposition and overall thickness more than 12-fold vs. controls, while dentin and cellular cementum were unaltered. Though PP(i regulators are widely expressed, cementoblasts selectively expressed greater ANK and NPP1 along the root surface, and dramatically increased ANK or NPP1 in models of reduced PP(i output, in compensatory fashion. In vitro mechanistic studies confirmed that under low PP(i mineralizing conditions, cementoblasts increased Ank (5-fold and Enpp1 (20-fold, while increasing PP(i inhibited mineralization and associated increases in Ank and Enpp1 mRNA.Results from these studies demonstrate a novel developmental regulation of acellular cementum, wherein cementoblasts tune cementogenesis by modulating local levels of PP(i, directing and

  5. Thermoluminescence of cerium and terbium -doped calcium pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Lozano R, I. B.; Diaz G, J. A. I., E-mail: jesus.roman@nucleares.unam.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The aim of this work is to report the thermoluminescence (Tl) response of Calcium Pyrophosphate phosphor doped with Cerium and Terbium impurities (Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+}). The phosphors were synthesized using the co-precipitation method and annealed at 900 degrees C by two hours for obtain the β phase. The intentional doping with Ce and Tb ions was 1 at.% and 0.1 at.%, whereas in the EDS results the concentration of impurities was 0.39 at.% and 0.05 at.%, respectively. The superficial morphology of phosphor is mainly composed by thin wafers of different size. All samples were exposed to gamma rays from {sup 60}Co in the Gammacell-200 irradiator. The Tl response of the phosphor was measured from Rt up to 350 degrees C and under nitrogen atmosphere in a Harshaw TLD 3500 reader. The glow curves of the Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+} powders showed a broad intense Tl peak centered at 165 degrees C and a shoulder at approximate 260 degrees C was observed. A linear Tl response in the range of absorbed dose of 0.2 to 10 Gy was obtained. Tl glow curves were analyzed using the initial rise (IR)and computerized glow curve deconvolution methods to evaluate the kinetics parameters such as activation energy (E), frequency factor (s) and kinetic order (b). (Author)

  6. Sup(99m)Tc-Sn-pyrophosphate complex. A stable, lyophilized radiopharmaceutical for skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Cvoric, J; Jovanovic, V; Bzenic, J [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia); Stefanovic, Lj; Selir, Z [Institute for Tuberculosis and Pectoral Diseases, Radioisotope Applications, Sremska Kamenica (Yugoslavia)

    1978-01-01

    After a systematic investigation of the different phosphate polymers, viz. hexametaphosphate, tripolyphosphate, meta- and diphosphonate, pyrophosphate (Na/sub 4/P/sub 2/O/sub 7/) was selected for sceletal scintigraphy. A procedure has been developed for obtaining a sup(99m)Tc-labelled Sn(II): PyP complex by addition of a sterile, apyrogenic pertechnetate solution from a sup(99m)Tc-generator to a lyophilized solution of Sn(II)-tetrasodium phosphate. ''Kit'' composition was determined on the basis of biodynamic data obtained when the Sn/pyrophosphate ratio, pH and other parameters were varied. In vivo distribution of different sup(99m)Tc-Sn-pyrophosphate complexes permitted the selection of the most suitable complex for sceletal scanning. The investigated complex is being successfully applied in human scintigraphy of bones in the Laboratory for Radioisotope Applications of the Institute for Tubercolosis and Pectoral Diseases in Sremska Kamenica.

  7. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy; Les radiopharmaceutiques marques au technetium-99m et la radiopharmacie

    Energy Technology Data Exchange (ETDEWEB)

    Bodenant, V

    1998-10-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  8. Review of technetium behavior in relation to nuclear waste disposal

    International Nuclear Information System (INIS)

    Paquette, J.; Reid, J.A.K.; Rosinger, E.L.J.

    1992-05-01

    This report contains available information which determine possible methods of the transfer of technetium element from waste disposal facilities to the biosphere. It also includes possible effects upon human beings and environment. 65 refs., 4 tabs., 3 figs

  9. Preparation and quality control of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  10. Physical chemical quality control of the molybdenum technetium generator

    International Nuclear Information System (INIS)

    Olive, E.; Cruz, J.; Isaac, M.; Gamboa, R.; D'Alessandro, K.; Desdin, L.F.

    1995-01-01

    Comparative operational procedure imported molybdenum technetium generators have been made. Procedures for determination of chemical, radiochemical and radionuclidic purities that may be applied in Hospital's laboratories and in the quality control of generators production are developed

  11. Biosynthesis of monoterpenes. Enantioselectivity in the enzymatic cyclization of (+)- and (-)-linalyl pyrophosphate to (+)- and (-)-pinene and (+)- and (-)-camphene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Cane, D.E.; Chang, C.C.

    1988-01-01

    Cyclase I from Salvia officinalis leaf catalyzes the conversion of geranyl pyrophosphate to the stereo-chemically related bicyclic monoterpenes (+)-alpha-pinene and (+)-camphene and to lesser quantities of monocyclic and acyclic olefins, whereas cyclase II from this plant tissue converts the same acyclic precursor to (-)-alpha-pinene, (-)-beta-pinene and (-)-camphene as well as to lesser amounts of monocyclics and acyclics. These antipodal cyclizations are considered to proceed by the initial isomerization of the substrate to the respective bound tertiary allylic intermediates (-)-(3R)- and (+)-(3S)-linalyl pyrophosphate. [(3R)-8,9-14C,(3RS)-1E-3H]Linalyl pyrophosphate (3H:14C = 5.14) was tested as a substrate with both cyclases to determine the configuration of the cyclizing intermediate. This substrate with cyclase I yielded alpha-pinene and camphene with 3H:14C ratios of 3.1 and 4.2, respectively, indicating preferential, but not exclusive, utilization of the (3R)-enantiomer. With cyclase II, the doubly labeled substrate gave bicyclic olefins with 3H:14C ratios of from 13 to 20, indicating preferential, but not exclusive, utilization of the (3S)-enantiomer in this case. (3R)- and (3S)-[1Z-3H]linalyl pyrophosphate were separately compared to the achiral precursors [1-3H]geranyl pyrophosphate and [1-3H]neryl pyrophosphate (cis-isomer) as substrates for the cyclizations. With cyclase I, geranyl, neryl, and (3R)-linalyl pyrophosphate gave rise exclusively to (+)-alpha-pinene and (+)-camphene, whereas (3S)-linayl pyrophosphate produced, at relatively low rates, the (-)-isomers. With cyclase II, geranyl, neryl, and (3S)-linalyl pyrophosphate yielded exclusively the (-)-isomer series, whereas (3R)-linalyl pyrophosphate afforded the (+)-isomers at low rates

  12. Under used technetium-99m generators

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2001-01-01

    Health care reform truly has become a global issue and it will undoubtedly have a dramatic impact on the future of nuclear medicine business in particular. A bigger concern within the nuclear medicine community is its competitiveness with other modalities and cost effectiveness.Technetium-99m and its generators are playing key role for the majority of diagnostic scans performed in the world today. Availability of ''9''9''mTc can be increased if it is separated from ''9''9Mo after much shorter growth times. After proper planning with the extra ''9''9''mTc, a significant number of scans can be performed or we would be able to order approximately 30% low activity ''9''9Tc generators to fulfill our requirements

  13. Technetium-99m-human fibrinogen

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.S.

    1975-01-01

    Exogenous fibrinogen has been successfully labeled with /sup 99m/Tc using a modified electrolytic method. The exact labeling mechanism has not been determined. Experimental data suggest that the labeling process of /99m/Tc-fibrinogen is quite similar to that of /sup 99m/Tc-human serum albumin as reported earlier by Benjamin. Technetium-99m-fibrinogen is stable in human plasma or in 1 percent buffered human serum albumin. A binding efficiency of 76 percent has been achieved with approximately 25 percent clottable protein. The entire labeling procedure requires less than 1 hr of preparation time. This short labeling time in a closed system may allow development of a practical method for labeling autologous fibrinogen, thus eliminating the risk of hepatitis transmission. (U.S.)

  14. Labeling of creatinine with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Yurt Lambrecht, F. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications, Inst. of Nuclear Sciences; Durkan, K. [Dokuz Eylul Univ., Buca, Izmir (Turkey). Chemistry Technicianship Program, Izmir Vocational School; Soylu, A. [Dokuz Eylul Univ., Narlidere, Izmir (Turkey). Dept. of Pediatrics, Medical Faculty

    2004-07-01

    Creatinine is a clinically important index of renal glomerular filtration rate. Urine creatinine levels can be used as a screening test to evaluate kidney function or can be part of the creatinine clearance test. In case of kidney dysfunction or muscle disorders the creatinine concentration in serum/plasma may rise to a higher value than in healthy body. Technetium- 99m has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. {sup 99m}Tc is utilized to label molecules and cells, used as radiopharmaceuticals, and also to label biological species. It presents many desirable characteristics. SnCl{sub 2} method is frequently used as a reducing agent in the {sup 99m}Tc- labeling process. Creatinine metabolism might be investigated by using labeled {sup 99m}Tc- creatinine in healthy or uremic rats. (orig.)

  15. Anionic sorbents for arsenic and technetium species

    International Nuclear Information System (INIS)

    Lucero, Daniel A.; Moore, Robert Charles; Bontchev, Ranko Panayotov; Hasan, Ahmed Ali Mohamed; Zhao, Hongting; Salas, Fred Manuel; Holt, Kathleen Caroline

    2003-01-01

    Two sorbents, zirconium coated zeolite and magnesium hydroxide, were tested for their effectiveness in removing arsenic from Albuquerque municipal water. Results for the zirconium coated zeolite indicate that phosphate present in the water interfered with the sorption of arsenic. Additionally, there was a large quantity of iron and copper present in the water, corrosion products from the piping system, which may have interfered with the uptake of arsenic by the sorbent. Magnesium hydroxide has also been proven to be a strong sorbent for arsenic as well as other metals. Carbonate, present in water, has been shown to interfere with the sorption of arsenic by reacting with the magnesium hydroxide to form magnesium carbonate. The reaction mechanism was investigated by FT-IR and shows that hydrogen bonding between an oxygen on the arsenic species and a hydrogen on the Mg(OH)2 is most likely the mechanism of sorption. This was also confirmed by RAMAN spectroscopy and XRD. Technetium exists in multiple oxidation states (IV and VII) and is easily oxidized from the relatively insoluble Tc(IV) form to the highly water soluble and mobile Tc(VII) form. The two oxidation states exhibit different sorption characteristics. Tc(VII) does not sorb to most materials whereas Tc(IV) will strongly sorb to many materials. Therefore, it was determined that it is necessary to first reduce the Tc (using SnCl2) before sorption to stabilize Tc in the environment. Additionally, the effect of carbonate and phosphate on the sorption of technetium by hydroxyapatite was studied and indicated that both have a significant effect on reducing Tc sorption

  16. The performance of gel technetium-99m generator

    International Nuclear Information System (INIS)

    Liu Yishu

    2004-01-01

    Technetium-99m, as one of the important radionuclides in nuclear medical science, has been widely used for diseases diagnosis in both developed and developing countries for many years. Technetium-99m can be obtained from both fission-type and gel-type Tc-99m generator. Fission-type generator was prepared by Molybdenum-99 separated from fission products of uranium-235 and gel-type was prepared by irradiating nature MoO 3 in reactor, and a series of chemical and physical processes. This paper briefly describes the manufacturing technical process of gel-type Technetium-99 generator, including the preparation of target containing nature MoO 3 , the target irradiation in reactor, gel preparation, gel filtration and drying, dried gel cracking, generator loading and activity calibration of generator. The performances of gel-type Technetium-99m generator, such as elution efficiency, elution profile, the pH, Mo breakthrough, Zirconium content, radiochemical purity, radionuclidic purity, sterility and pyrogencity of eluate, are also expatiated in detail. Comparing with fission-type Technetium-99m generator, the defects of gel-type Technetium-99m generator are enumerated and their overcoming solutions are recommended in this paper. (author)

  17. Study of the synthesis of ammonia over technetium catalysts

    International Nuclear Information System (INIS)

    Spetsyn, V.I.; Mikhailenko, I.E.; Pokrovskaya, O.V.

    1982-01-01

    The catalytic properties of technetium in the synthesis of ammonia have been studied in the present work. Technetium catalysts according to specific yield surpass all know catalysts for the synthesis of ammonia. The enhanced catalytic activity of technetium compared to manganese and rhenium is apparently explained by the presence of the radioactivity of 99 Tc. The processes of adsorption, orientation of the adsorbed molecules, and their binding energies can differ during radiation action. Irradiation of the carrier, occurring through #betta#-emission of 99 Tc, with doses of 4-8 x 10 3 rad/day, increased the number of defects in the crystal structure where stabilization of technetium atoms was possible. The existence of charged centers can cause an increase in the dissociative chemisorption of nitrogen, which is the limiting stage of the process. Technetium catalysts possess a stable catalytic activity and do not require its restoration for several months. Results suggest that the use of technetium as a catalyst for the synthesis of ammonia has real advantages and potential possibilities

  18. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    International Nuclear Information System (INIS)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patients were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy

  19. Visualization of rhabdomyolysis with scintigraphy with Tc99m pyrophosphate: presentation of a clinical case

    International Nuclear Information System (INIS)

    Pruzzo C, Rossana; Amaral P, Horacio; Morales K, Barbara; Hurtado, Ester

    2000-01-01

    We present a case of secondary rhabdomyolysis due to vascular ischemia after dissection of the proximal aorta and obstruction of the left femoral artery after cocaine consumption. A Tc99m-pyrophosphate whole body scan demonstrated the presence of rhabdomyolysis in both lower extremities (Au)

  20. Determination of pyrophosphate and sulfate using polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles.

    Science.gov (United States)

    Terenteva, E A; Apyari, V V; Dmitrienko, S G; Garshev, A V; Volkov, P A; Zolotov, Yu A

    2018-04-01

    Positively charged polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles (PHMG-AgNPs) were prepared and applied as a colorimetric probe for single-step determination of pyrophosphate and sulfate. The approach is based on the nanoparticles aggregation leading to change in their absorption spectra and color of the solution. Due to both electrostatic and steric stabilization these nanoparticles show decreased sensitivity relatively to many common anions, which allows for simple and rapid direct single-step determination of pyrophosphate and sulfate. Effects of different factors (time of interaction, pH, concentrations of anions and the nanoparticles) on aggregation of PHMG-AgNPs and analytical performance of the procedure were investigated. The method allows for the determination of pyrophosphate and sulfate in the range of 0.16-2μgmL -1 and 20-80μgmL -1 with RSD of 2-5%, respectively. The analysis can be performed using either spectrophotometry or naked-eye detection. Practical application of the method was shown by the example of pyrophosphate determination in baking powder sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Tc-99m pyrophosphate scanning after ischemic exercise in McArdle's disease

    International Nuclear Information System (INIS)

    Uno, Hideaki; Kawano, Keizo; Yukawa, Susumu; Nomoto, Hiroshi

    1982-01-01

    In order to clarify the mechanism of muscle contracture induced by ischemic exercise in a patient with McArdle's disease, bone scanning with Tc-99m pyrophosphate was performed. The clinical diagnosis was established in the patient based on the biochemical examinations of skeletal muscle biopsy. Ischemic exercise was done initially on the left forearm and then 20 hours later on the right forearm. Two hours later, 15 mCi of Tc-99m pyrophosphate was infused through the left antecubital vein. Exactly 4 hours later, a conventional bone scanning was carried out. In the patient with McArdle's disease, muscle contracture developed in both forearms during the ischemic exercise. Conventional bone scanning showed increased Tc-99m pyrophosphate labeling of the right forearm muscles at 2 hours after ischemic exercise. However, increased labeling of the left forearm muscles was not found at 22 hours after ischemic exercise. In the control, no muscle contracture developed during ischemic exercise and bone scan showed no increase in Tc-99m pyrophosphate labeling in the antebrachial region. These findings suggest that the basis of muscle contracture appears to be an increased concentration of Ca in muscle cells due to a failure of sarcoplasmic reticulum to reaccumulate Ca at ischemic exercise. (author)

  2. Stabilization through precipitation in a system of colloidal iron(III) pyrophosphate salts

    NARCIS (Netherlands)

    van Leeuwen, Y.M.; Velikov, K.P.; Kegel, W.K.

    2012-01-01

    The ionic strength of a solution decreases during the precipitation of an insoluble salt, which can cause an initially unstable colloidal system to stabilize during its formation. We show this effect in the precipitation and aging of colloidal iron(III) pyrophosphate, where we observe two distinct

  3. Hyaline cartilage involvement in patients with gout and calcium pyrophosphate deposition disease. An ultrasound study.

    Science.gov (United States)

    Filippucci, E; Riveros, M Gutierrez; Georgescu, D; Salaffi, F; Grassi, W

    2009-02-01

    The main aim of the present study was to determine the sensitivity, specificity and accuracy of ultrasonography (US) in detecting monosodium urate and calcium pyrophosphate dihydrate crystals deposits at knee cartilage level using clinical definite diagnosis as standard reference. A total of 32 patients with a diagnosis of gout and 48 patients with pyrophosphate arthropathy were included in the study. Fifty-two patients with rheumatoid arthritis (RA), psoriatic arthritis or osteoarthritis (OA) were recruited as disease controls. All diagnoses were made using an international clinical criterion. US examinations were performed by an experienced sonographer, blind to clinical and laboratory data. Hyaline cartilage was assessed to detect two US findings recently indicated as indicative of crystal deposits: hyperechoic enhancement of the superficial margin of the hyaline cartilage and hyperechoic spots within the cartilage layer not generating a posterior acoustic shadow. Hyperechoic enhancement of the chondrosynovial margin was found in at least one knee of 14 out of 32 (43.7%) patients with gout and in a single knee of only one patient affected by pyrophosphate arthropathy (specificity=99%). Intra-cartilaginous hyperechoic spots were detected in at least one knee of 33 out of 48 (68.7%) patients with pyrophosphate arthropathy and in two disease controls one with OA and the second with RA (specificity=97.6%). The results of the present study indicate that US may play a relevant role in distinguishing cartilage involvement in patients with crystal-related arthropathy. The selected US findings were found to be highly specific.

  4. Sensor Function for Butyrophilin 3A1 in Prenyl Pyrophosphate Stimulation of Human Vγ2Vδ2 T Cells

    Science.gov (United States)

    Wang, Hong; Morita, Craig T.

    2016-01-01

    Vγ2Vδ2 T cells play important roles in human immunity to pathogens and in cancer immunotherapy by responding to isoprenoid metabolites, such as (E)-4-hydroxy-3-methyl-but-2-enyl pyrophosphate and isopentenyl pyrophosphate. The Ig superfamily protein butyrophilin (BTN)3A1 was shown to be required for prenyl pyrophosphate stimulation. We proposed that the intracellular B30.2 domain of BTN3A1 binds prenyl pyrophosphates, resulting in a change in the extracellular BTN3A1 dimer that is detected by Vγ2Vδ2 TCRs. Such B30.2 binding was demonstrated recently. However, other investigators reported that the extracellular BTN3A1 IgV domain binds prenyl pyrophosphates, leading to the proposal that the Vγ2Vδ2 TCR recognizes the complex. To distinguish between these mechanisms, we mutagenized residues in the two binding sites and tested the mutant BTN3A1 proteins for their ability to mediate prenyl pyrophosphate stimulation of Vγ2Vδ2 T cells to proliferate and secrete TNF-α. Mutagenesis of residues in the IgV site had no effect on Vγ2Vδ2 T cell proliferation or secretion of TNF-α. In contrast, mutagenesis of residues within the basic pocket and surrounding V regions of the B30.2 domain abrogated prenyl pyrophosphate-induced proliferation. Mutations of residues making hydrogen bonds to the pyrophosphate moiety also abrogated TNF-α secretion, as did mutation of aromatic residues making contact with the alkenyl chain. Some mutations further from the B30.2 binding site also diminished stimulation, suggesting that the B30.2 domain may interact with a second protein. These findings support intracellular sensing of prenyl pyrophosphates by BTN3A1 rather than extracellular presentation. PMID:26475929

  5. Technetium 99-m labeled radio-diagnostic agents employing stannous tartrate and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1976-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung. 31 claims, no drawings

  6. Assessment of Technetium in the Savannah River Site Environment

    International Nuclear Information System (INIS)

    Carlton, W.H.; Denham, M.; Evans, A.G.

    1993-07-01

    Assessment of Technetium in the Savannah River Site Environment is the last in a series of eight documents on individual radioisotopes released to the environment as a result of SRS operations. The earlier documents describe the environmental consequences of tritium cesium, iodine, uranium plutonium, strontium, and carbon. Technetium transport and metabolism have been studied by the nuclear industry because it is a fission product of uranium, and by the medical community because 99m Tc commonly is used as a diagnostic imaging agent in nuclear medicine. Technetium has been produced at SRS during the operation of five production reactors. The only isotope with environmental significance is 99 Tc. Because of the small activities of 99 Tc relative to other fission products, such as 90 Sr and 137 Cs, no measurements were made of releases to either the atmosphere or surface waters. Dose calculations were made in this document using conservative estimates of atmospheric releases and from a few measurements of 99 Tc concentrations in the Savannah River. Technetium in groundwater has been found principally in the vicinity of the separation areas seepage basins. Technetium is soluble in water and follows groundwater flow with little retardation. While most groundwater samples are negative or show little technetium a few samples have levels slightly above the limits set by the EPA for drinking water. The overall radiological impact of SRS 99 Tc releases on the offsite maximally exposed individual during 38 years of operations can be characterized by maximum individual doses of 0.1 mrem (atmospheric) and 0.8 mrem (liquid), compared with a dose of 13,680 mrem from non-SRS sources during the same time period. Technetium releases have resulted in a negligible risk to the environment and the population it supports

  7. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    International Nuclear Information System (INIS)

    Perani, D.; Di Piero, V.; Vallar, G.

    1988-01-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ([/sup 99m/Tc]HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data

  8. Clinical evaluation of salivary gland imaging with technetium-99m pertechnetate 43 cases

    International Nuclear Information System (INIS)

    Huang Daming

    1989-01-01

    Salivary gland imaging in 36 patients with benign or malignant tumor all showed the size, extent and location of tumor in parotid glands. There was no pseudonegative diagnosis in salivary gland imaging, but in sailography there were three cases with pseudo-negative diagnosis. The authors believe salivary gland imaging with Technetium-99m pertechnetate although is nonspecific for Warthin's tumor of parotid gland, and is also not able to differentiate malignant tumor from benign tumor of salivary gland, but radionuclide examination is a safe and simple diagnostic technnique and proves to have greater sensitivity in demonstrating abnormalities of salivary gland than that of routine sailography. Contrast salivarry gland imaging with sailography one can differentiate inflammation from tumor and benign from malignant tumor

  9. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  10. TESTING GUIDELINES FOR TECHNETIUM-99 ADSORPTION ON ACTIVATED CARBON

    International Nuclear Information System (INIS)

    Byrnes, M.E.

    2010-01-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs) will

  11. TESTING GUIDELINES FOR TECHNETIUM-99 ABSORPTION ON ACTIVATED CARBON

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2010-09-08

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs

  12. Final Report, Research Program to Investigate the Fundamental Chemistry of Technetium

    International Nuclear Information System (INIS)

    Lukens, Wayne W. Jr.; Fickes, Michael J.; Bucher, Jerome J.; Burns, Carol J.; Edelstein, Norman M.; Shuh, David K.

    2000-01-01

    The purpose is to increase the basic scientific understanding of technetium chemistry to better understand the behavior of technetium in chemical environments relevant to DOE. Two important areas in need of study are the behavior of technetium in highly alkaline solutions similar to high-level nuclear waste, and its behavior in different waste forms. This research program addressed these two needs. Two separate approaches were used in this program. The first focus was to understand the basic solution chemistry of technetium, which underlies its behavior in the highly alkaline environment of the nuclear waste tanks located at the Savannah River and Hanford Sites. The specific problems at these sites are related to the anomalous oxidation state of technetium (Schroeder 1995). Although, at high pH, technetium should exist in its highest oxidation state as TcO 4 - , soluble, lower-valent technetium species have been observed in certain wastes. The specific unknowns that this program sought to answer are the nature of lower valent technetium species that can be formed in highly alkaline solution and whether pertechnetate undergoes radiolytic reduction in highly alkaline solution when nitrate is present in excess. The second focus area is the behavior of technetium immobilized in various waste forms. The behavior of technetium in cement wastes was examined to gain information about its long-term stability. Specifically, this research examined the oxidation of reduced technetium species by components present in high-level waste that are incorporated into cement waste along with technetium

  13. The quality control of technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1983-08-01

    The methods of quality control used for technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment are described for both non-fission and fission derived sources of sodium pertechnetate, technetium-99m labelled radipopharmaceuticals, and reagent kits produced for technetium-99m labelling

  14. Experimental measurements of the solubility of technetium under near-field conditions

    International Nuclear Information System (INIS)

    Pilkington, N.J.; Wilkins, J.D.

    1988-05-01

    The solubility of technetium in contact with hydrated technetium dioxide under near-field conditions has been measured experimentally. The values obtained were changed little by a change in pH or in the filtration method used. The presence of organic degradation products increased slightly the solution concentration of technetium. (author)

  15. Final Report, Research Program to Investigate the Fundamental Chemistry of Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Lukens Jr., Wayne W.; Fickes, Michael J.; Bucher, Jerome J.; Burns, Carol J.; Edelstein, Norman M.; Shuh, David K.

    2000-12-23

    The purpose is to increase the basic scientific understanding of technetium chemistry to better understand the behavior of technetium in chemical environments relevant to DOE. Two important areas in need of study are the behavior of technetium in highly alkaline solutions similar to high-level nuclear waste, and its behavior in different waste forms. This research program addressed these two needs. Two separate approaches were used in this program. The first focus was to understand the basic solution chemistry of technetium, which underlies its behavior in the highly alkaline environment of the nuclear waste tanks located at the Savannah River and Hanford Sites. The specific problems at these sites are related to the anomalous oxidation state of technetium (Schroeder 1995). Although, at high pH, technetium should exist in its highest oxidation state as TcO{sub 4}{sup {minus}}, soluble, lower-valent technetium species have been observed in certain wastes. The specific unknowns that this program sought to answer are the nature of lower valent technetium species that can be formed in highly alkaline solution and whether pertechnetate undergoes radiolytic reduction in highly alkaline solution when nitrate is present in excess. The second focus area is the behavior of technetium immobilized in various waste forms. The behavior of technetium in cement wastes was examined to gain information about its long-term stability. Specifically, this research examined the oxidation of reduced technetium species by components present in high-level waste that are incorporated into cement waste along with technetium.

  16. Sorption characteristics of technetium on crosslinked chitosan from aqueous solution

    International Nuclear Information System (INIS)

    Pivarciova, L.; Rosskopfova, O.; Galambos, M.; Rajec, P.

    2014-01-01

    Sorption of technetium on crosslinked chitosan was studied using batch techniques in static arrangement of experiment under aerobic conditions at laboratory temperature. The adsorption of technetium was rapid and the percentage of the technetium sorption was > 98 %. In the pH range of 3-11 adsorption of technetium on crosslinked chitosan was > 98 %. The competition effect of Fe 3+ towards TcO 4 - sorption on crosslinked chitosan was stronger than the competition effect of other observed cations. The selectivity of crosslinked chitosan for these cations in solution with the concentration above 1·10 -3 mol·dm -3 was in the order Fe 3+ > Ca 2+ > Na + > Fe 2+ . The competition effect of (ClO 4 ) - towards TcO 4 - sorption was stronger than the competition effect of (SO 4 ) 2 - ions. From these results it can be expected that crosslinked chitosan could be a suitable sorbent for the immobilization of technetium in the liquid radioactive waste. (authors)

  17. Uptake and distribution of technetium in several marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Gerber, G.B.; Garten, C.T. Jr.; Vandecasteele, C.M.; Myttenaere, C.; Van Baelen, J.; Cogneau, M.; van der Ben, D.

    1983-01-01

    The uptake or chemical form of technetium in different marine algae (Acetabularia, Cystoseira, Fucus) has been examined and a simple model to explain the uptake of technetium in the unicellular alga, Acetabularia, has been conceptualized. At low concentrations in the external medium, Acetabularia can rapidly concentrate technetium. Concentration factors in excess of 400 can be attained after a time of about 3 weeks. At higher mass concentrations in the medium, uptake of technetium by Acetabularia becomes saturated resulting in a decreased concentration factor (approximately 10 after 4 weeks). Approximately 69% of the total radioactivity present in /sup 95m/Tc labelled Acetabularia is found in the cell cytosol. In Fucus vesiculosus, labelled with /sup 95m/Tc, a high percentage of technetium is present in soluble ionic forms while approximately 40% is bound, in this brown alga, in proteins and polysaccharides associated with cell walls. In the algal cytosol of Fucus vesiculosus, about 45% of the /sup 95m/Tc appears to be present as anionic TcO - 4 and the remainder is bound to small molecules. 8 references, 5 figures, 1 table

  18. Complexes of technetium with polyhydric ligands

    International Nuclear Information System (INIS)

    Hwang, L.L.Y.; Ronca, N.; Solomon, N.A.; Steigman, J.

    1985-01-01

    Polyhydric complexes of Tc(V) show absorption bands near 500 nm, with molar absorptivity coefficients of about 100. The shorter-chain compounds like ethylene glycol produce complexes which quickly disproportionate to Tc(IV) (as TcO 2 ) and Tc(VII) (as TcO 4 - ) on acidification. The longer-chain ligands like mannitol and gluconate do not. However, while the mannitol complex shows no change in spectrum from pH 12 to pH 3, the gluconate and glucoheptonate compounds show a definite spectral change on acidification, starting at pH 5. Electrophoresis similarity showed a change in mobility with pH for Tc-glucoheptonate, but none for Tc-mannitol. It was concluded that the carboxylic acid group of glucoheptonate was not binding the technetium. In 25 molal choline chloride the glucoheptonate-Tc mole ratio was 1:1 or less. A similar result emerged from a similar experiment in methylcellosolve as solvent. (author)

  19. Technetium cyanide chemistry: synthesis and characterization of technetium(III) and -(V) cyanide complexes

    International Nuclear Information System (INIS)

    Trop, H.S.; Jones, A.G.; Davison, A.

    1980-01-01

    Several new technetium cyanide complexes have been prepared and characterized. The reaction of ammonium hexaiodotechnetate(IV) with potassium cyanide in refluxing aqueous methanol under nitrogen yields potassium heptacyanotechnetate(III) dihydrate, K 4 Tc(CN) 7 .2H 2 O (1). Infrared and Raman measurements indicate that 1 has a pentagonal bipyramidal structure (D/sub 5h/) in both solid and solution. Aqueous solutions of 1 are air sensitive, decomposing to potassium oxopentacyanotechnetate(V) tetrahydrate, K 2 TcO(CN) 5 .4H 2 O (2). This species can also be prepared from the reaction of TcO 2 .xH 2 O with hot aqueous potassium cyanide solutions. Hydrolysis of 2 in water yields potassium trans-dioxo-tetracyanotechnetate(V), K 3 TcO 2 (CN) 4 (3). Preparation of 3 can also be achieved from the treatment of [TcO 2 (Py) 4 ]ClO 4 .2H 2 O with aqueous potassium cyanide. Infrared and Raman measurements on 3 are consistent with the proposed trans-dioxo (D/sub 4h/) structure. Reaction of the oxotetrachlorotechnetate(V) anion, TcOCl 4 , with potassium cyanide in methanol produces trans-oxomethoxytetracyanotechnetate(V). [TcO(OMe)(CN) 4 ] (4). The full details of the synthesis and characterization of these interesting technetium(III) and -(V) complexes, as well as observations on the infrared and Raman spectra of trans-dioxo metal complexes and the hydrolysis of species 2, are presented

  20. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  1. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  2. Thallium-201 and technetium-99m pertechnetate subtraction scintigraphy in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Koizumi, Mitsuru; Goto, Masafumi; Nomura, Toshiharu; Fujioka, Mutsuhisa; Watari, Tsutomu

    1992-01-01

    A reliable technique for detecting and localizing abnormal parathyroid tissue has been a persistent problem. We evaluated thallium-technetium (Tl/Tc) subtraction scintigraphy in 16 patients with clinical biochemical evidence of hyperparathyroidism prior to other diagnostic methods and surgery. Seven patients had surgery and were confirmed to have parathyroid adenoma or hyperplasia. The other methods included ultrasonography (US) in 6 patients, computed tomography (CT) in 10 patients, magnetic resonance imaging (MRI) in 8 patients, and bone scintigraphy in 7 patients. In patients who had several imaging modalities, the detection rate was significantly better for Tl/Tc subtraction scan than for US, CT or MRI. Bote scintigraphy, though not so sensitive as Tl/Tc subtraction studies, was an important tool for evaluating metabolic bone disorder including hyperparathyroidism and renal osteodystrophy. Thus, Tl/Tc subtraction scan is more useful for diagnosis when hyperparathyroidism is suspected if both Tl/Tc subtraction scan and bone scan are performed. The detectability depended on the mass size, and detection of abnormal glands was greater for adenoma than for hyperplasia. The results suggest that Tl/Tc subtraction scan is a simple, non-invasive and useful tool for locating parathyroid abnormality even when compared with MRI. (author)

  3. Technetium behaviour in Boom Clay - a laboratory and field study

    Energy Technology Data Exchange (ETDEWEB)

    Baston, G.M.N.; Ilett, D.J.; Cowper, M.M.; Pilkington, N.J.; Tweed, C.J.; Williams, S.J. [AEA Technology plc, Harwell, Didcot, Oxfordshire (United Kingdom); Canniere, P.R. de; Wang, L. [SCK.CEN, Waste and Disposal Project, Boeretang, Mol (Belgium)

    2002-07-01

    This paper describes a study of technetium solubility and migration under chemical conditions representative of those prevailing in a Boom Clay environment. Laboratory and in situ measurements yielded similar aqueous concentrations of technetium, of about 1 x 10{sup -8} mol dm{sup -3}, close to the concentrations measured for hydrated technetium(IV) oxide TcO{sub 2}.1.6H{sub 2}O in the solubility studies. From fitting the curves of the Tc concentrations as function of time, distribution coefficient (K{sub d}) values were estimated to lie between 0.8 cm{sup 3} g{sup -1} and 1.8 cm{sup 3} g{sup -1}. Exposure of the system at 80 C and to {gamma}-radiation dose rates of several hundred Gy h{sup -1} resulted in only minor differences in behaviour. (orig.)

  4. Technetium behaviour in Boom Clay - a laboratory and field study

    International Nuclear Information System (INIS)

    Baston, G.M.N.; Ilett, D.J.; Cowper, M.M.; Pilkington, N.J.; Tweed, C.J.; Williams, S.J.; Canniere, P.R. de; Wang, L.

    2002-01-01

    This paper describes a study of technetium solubility and migration under chemical conditions representative of those prevailing in a Boom Clay environment. Laboratory and in situ measurements yielded similar aqueous concentrations of technetium, of about 1 x 10 -8 mol dm -3 , close to the concentrations measured for hydrated technetium(IV) oxide TcO 2 .1.6H 2 O in the solubility studies. From fitting the curves of the Tc concentrations as function of time, distribution coefficient (K d ) values were estimated to lie between 0.8 cm 3 g -1 and 1.8 cm 3 g -1 . Exposure of the system at 80 C and to γ-radiation dose rates of several hundred Gy h -1 resulted in only minor differences in behaviour. (orig.)

  5. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  6. Importance of scintigraphy of the myocardium with Csup(99m)-Tc-pyrophosphate in the diagnosis of myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Botnar' , V I; Dvoskina, I S [Inst. Kardiologii Vsesoyuznogo Kardiologicheskogo Nauchnogo Tsentra AN SSSR

    1983-10-01

    The following aspects of the method of scintigraphy of the myocardium with sup(99m)Tc-pyrophosphate as test sensitivity, possibility of estimating necrosis focus, prognostic importance of the method, scintigram dynamics in case of acute infarction, pyrophosphate accumulation in myocardial cells are considered. Advantages and prospects of the method for visualization of acute myocardium infarction focus and in cases of other pathological states are pointed out.

  7. Insolubilization of technetium by microorganisms in waterlogged soils

    International Nuclear Information System (INIS)

    Ishii, Nobuyoshi; Tagami, Keiko

    2003-01-01

    In order to clarify the technetium behavior in paddy field ecosystem, insolubilization of technetium in the water covering waterlogged soils was studied. Fourteen soils collected from paddy fields (9 samples) and upland fields (5 samples) were waterlogged for 7 days. After the collection of water covering the waterlogged soils, a radio tracer 95m TcO 4 - was added to the water. After 4 days incubation of the water, the tracer was separated into four fractions: insoluble, pertechnetate, cationic, and other forms of technetium. On an average, 13% of the 95m TcO 4 - changed to insoluble forms and the maximum ratio of the insolubilization was 76%. This result shows that insolubilization of technetium can occur in the water covering the waterlogged soils. Subsequently, mechanisms of Tc insolubilization were studied using the sample that showed the maximum insolubilization of Tc among the soil samples. When microorganisms were removed from the water by filtration, insoluble forms of Tc decreased to 3.6%. In contrast, the insolubilization ratio increased to 86% by the addition of organic substrates. The insolubilization, therefore, was caused by microorganisms. Furthermore, the addition of antibiotics on bacteria resulted in 23% of the insolubilization, while the antibiotic on fungi did not affect on the insolubilization. If the insolubilization were caused by biosorption, the insolubilization ratio would not decrease for the sample added antibiotics on bacteria. Therefore, these results suggest that the insolubilization of technetium is caused by bioaccumulation of living bacteria. Because the cultures with 95m TcO 4 - were incubated under aerobic conditions, technetium-insolubilizing microorganisms would presumably be aerobic bacteria. (author)

  8. Absorption of technetium by plants in relation to soil type contamination level and time

    Energy Technology Data Exchange (ETDEWEB)

    Mousny, J.M.; Myttenaere, C. (Louvain Univ. (Belgium). Lab. de Physiologie Vegetale)

    1981-01-01

    Plants of Pisum sativum (var. Merveille de Kelvedon) were grown on seven typical european soils contaminated with different levels of /sup 99/Tc(0.17; 1.7 and 17 ..mu..Ci/kg). Added initially as pertechnetate, the technetium absorption has been studied for three successive cultures. The translocation of technetium from soil to plant leaves is high, but its transfer is reduced in soils rich in organic matter (Fen) or poorly drained (Braunerde). Aging reduces the technetium transfer and modify its relative distribution in plant (relatively more technetium is found in fruits); these results let suppose some modification of the technetium chemical form in soils with time.

  9. Study on interference of technetium in spectrophotometric estimation of uranium

    International Nuclear Information System (INIS)

    Revathi, P.; Saipriya, K.; Madhavan Kutty, V.K.; Srinivasa Rao, G.; Vijayakumar, N.; Kumar, T.

    2015-01-01

    Estimation of uranium is essential for process control purposes as well as to arrive optimum parameters for further waste management in reprocessing industry. Uranium estimation is done by spectrophotometry using ammonium thiocyanate, DBM, PAR and Br-PADAP as chromogenic reagents for colour development. Extractive spectrophotometry can also be used to eliminate some of the interfering ions. During inter method comparison, technetium was found to be interfering in the thiocyanate spectrophotometry. This study is an effort to find out the extent of technetium interference in the estimation of uranium by spectrophotometry using the above said chromogenic reagents. (author)

  10. Determination of technetium by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Kaye, J.H.; Ballou, N.E.

    1978-01-01

    A detection limit of 6 x 10 -11 g has been achieved for measurement of technetium by graphite furnace atomic absorption spectrometry. A commercially available, demountable, hollow cathode lamp was used and both argon and neon were used as fill gases for the lamp. The range of applicability of the method, when the unresolved 2614.23 to 2615.87 A doublet is used for analysis, is from 60 pg to at least 3 ng of technetium per aliquot analyzed. 3 figures, 1 table

  11. Selective sorption of technetium from groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.M. [Oak Ridge National Lab., TN (United States)

    1997-10-01

    Groundwater used for processing uranium or plutonium at DOE sites is frequently contaminated with the radionuclide {sup 99}Tc. DOE`s Paducah and Portsmouth sites are typical of the contamination problem. Solutions contaminated with radionuclides were poured into lagoons and burial pits, which created a plume that has seeped into the sandy aquifers below the vadose zone. Technetium is the principal radioactive metal-ion contaminant in Paducah site ground-water, and it is present at a concentration of about 25 ng/L. At Portsmouth, Tc is present in the groundwater at a concentration that varies greatly with distance from the source, and concentrations of >400 ng/L have been reported. Commercially available anion-exchange resins can remove the TcO{sub 4}{sup {minus}} ion in the presence of typical anions found in groundwater, but improving the selectivity will result in substantial cost savings in terms of the quantity of resin needed and the scale of the equipment required to treat huge flows rates. The pertechnetate anion is strongly sorbed on commercially-available strong-base anion-exchange resins, but in view of the low (typically nanomolar) concentrations of Tc involved, enhanced selectivity for the pertechnetate anion over other anions commonly found in groundwater such as chloride, sulfate, and nitrite will be needed. The authors have prepared and evaluated new anion-exchange resins that were designed to be highly selective for pertechnetate. The technology involves building those features that are known to enhance the selectivity of pertechnetate over other anions into the exchange sites of the resin (hydrophobicity), while at the same time maintaining favorable exchange kinetics.

  12. Behavior of technetium in freshwater environments

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G.; Frank, M.L.; Hoffman, F.O.; DeAngelis, D.L.

    1984-01-01

    In a previous study, /sup 95m/Tc, as a pertechnetate, was released to a small, experimental, freshwater pond, and the concentrations were determined in biotic and abiotic components of the pond ecosystem. A simple mathematical model was developed to predict the concentration of /sup 95m/Tc in fish and snails. Results from this study indicated that uptake through the food chain was an important source of technetium to the higher trophic levels (i.e., fish). In the current study, an experimental pond was spiked with /sup 95m/Tc in the pertechnetate form, and the concentrations of /sup 95m/Tc were measured in the lower trophic levels. Emphasis was placed on measuring the concentration of /sup 95m/Tc in zooplankton, benthic invertebrates, and the aquatic macrophyte Elodea canadensis. Fish were excluded from the pond to allow the development of a large zooplankton population. The concentration of /sup 95m/Tc in water decreased from 0.75 Bq/mL 1 h after the pond was spiked, to 0.21 Bq/mL at 20 d. Throughout the experiment, at least 98% of the /sup 95m/Tc in the water was in the dissolved fraction (0.4 ..mu..m). Zooplankton accumulated /sup 95m/Tc rapidly, having concentration factors (Bq/g sample wet wt. divided by Bq/g water) ranging from 3 at 4 h to 36 at 20 d. Concentration factors ranged from 3 to 8 for benthic insects and from 1 to 62 for the aquatic macrophyte.

  13. Distribution of technetium-99 in surface soils

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2000-01-01

    Technetium-99 ( 99 Tc) is an important fission product which has been widely distributed in the environment as a result of fallout from nuclear weapons testing. In order to improve our understanding of the behavior of 99 Tc in the environment, it is essential that we obtain more reliable information on the levels, distribution and fate of 99 Tc in the environment. In this study, the concentration of global fallout 99 Tc, in several surface soil samples (0 - 20 cm) collected in Japan, were determined by ICP-MS (inductively coupled plasma mass spectroscopy). The range of 99 Tc in rice paddy field, upland field and other soils determined in this study were 0.006 - 0.11, 0.004 - 0.008 and 0.007 - 0.02 Bq kg -1 dry, respectively. 137 Cs was used as a comparative indicator for the source of 99 Tc, because the fission yields from 235 U and 239 Pu were about the same (ca. 6%) for the two isotopes, and the behavior and distribution of 137 Cs in the environment is reasonably well understood. The 137 Cs contents in rice paddy field, upland field and other soils range between 1.7 - 28, 1.4 - 9.2 and -1 dry, respectively. The activity ratios of 99 Tc/ 137 Cs in all soil samples were (0.6 - 5.9) x 10 -3 . Most of the measured ratios were one order of magnitude higher than the theoretical one obtained from fission. However, this ratio in soil, presumably depends on not only both the characteristic of radionuclides and the soil, but also on their contents after deposition to the earth's surface. (author)

  14. Configuration Entropy Calculations for Complex Compounds Technetium

    International Nuclear Information System (INIS)

    Muhayatun; Susanto Imam Rahayu; Surdia, N.M.; Abdul Mutalib

    2002-01-01

    Recently, the study of technetium complexes is rapidly increasing, due to the benefit of 99m Tc complexes (one of Tc nuclear isomers), which are widely used for diagnostics. Study of the structure-stability relationship of Tc complexes based on solid angle has been done by Kung using a Solid Angle Factor Sum (SAS). The SAS is hypothesized to be related to stability. SAS has been used by several researchers either for synthesis or designing the reaction route of the Tc complex formation and predicting the geometry of complex structures. Although the advantages of the SAS were very gratifying, but the model does not have the theoretical basis which is able to explain the correlation of steric parameters to physicochemical properties of complexes especially to those connected to a complex's stability. To improve the SAS model, in this research the model was modified by providing a theoretical basis for SAS. The results obtained from the correlation of the SAS value to the thermodynamic stability parameters of simple complexes show the values to have a similar trend as the standard entropy (S 0 ). The entropy approximation model was created by involving some factors which are not used in Kung's model. Entropy optimization to the bond length (ML) has also been done to several complexes. The calculations of SAS value using the calculated R for more than 100 Tc complexes provide a normalized mean value of 0.8545 ± 0.0851 and have similar curve profiles as those of Kung's model. The entropy value can be obtained by multiplying the natural logarithm of the a priori degeneracy of a certain distribution (Ω) and the Boltzmann constant. The results of Ω and In Ω of the Tc complexes have a narrow range. The results of this research are able to provide a basic concept for the SAS to explain the structure-stability relationship and to improve Kung's model. (author)

  15. Behavior of technetium in freshwater environments

    International Nuclear Information System (INIS)

    Blaylock, B.G.; Frank, M.L.; Hoffman, F.O.; DeAngelis, D.L.

    1984-01-01

    In a previous study, /sup 95m/Tc, as a pertechnetate, was released to a small, experimental, freshwater pond, and the concentrations were determined in biotic and abiotic components of the pond ecosystem. A simple mathematical model was developed to predict the concentration of /sup 95m/Tc in fish and snails. Results from this study indicated that uptake through the food chain was an important source of technetium to the higher trophic levels (i.e., fish). In the current study, an experimental pond was spiked with /sup 95m/Tc in the pertechnetate form, and the concentrations of /sup 95m/Tc were measured in the lower trophic levels. Emphasis was placed on measuring the concentration of /sup 95m/Tc in zooplankton, benthic invertebrates, and the aquatic macrophyte Elodea canadensis. Fish were excluded from the pond to allow the development of a large zooplankton population. The concentration of /sup 95m/Tc in water decreased from 0.75 Bq/mL 1 h after the pond was spiked, to 0.21 Bq/mL at 20 d. Throughout the experiment, at least 98% of the /sup 95m/Tc in the water was in the dissolved fraction (0.4 μm). Zooplankton accumulated /sup 95m/Tc rapidly, having concentration factors (Bq/g sample wet wt. divided by Bq/g water) ranging from 3 at 4 h to 36 at 20 d. Concentration factors ranged from 3 to 8 for benthic insects and from 1 to 62 for the aquatic macrophyte

  16. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    Science.gov (United States)

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    The inositol pyrophosphates, molecular messengers containing an energetic pyrophosphate bond, impact a wide range of biologic processes. They are generated primarily by a family of three inositol hexakisphosphate kinases (IP6Ks), the principal product of which is diphosphoinositol pentakisphosphate (IP7). We report that IP6K2, via IP7 synthesis, is a major mediator of cancer cell migration and tumor metastasis in cell culture and in intact mice. IP6K2 acts by enhancing cell-matrix adhesion and decreasing cell–cell adhesion. This action is mediated by IP7-elicited nuclear sequestration and inactivation of the tumor suppressor liver kinase B1 (LKB1). Accordingly, inhibitors of IP6K2 offer promise in cancer therapy. PMID:25617365

  17. Effect of intra-articular yttrium-90 on chronic pyrophosphate arthropathy of the knee

    International Nuclear Information System (INIS)

    Doherty, M.; Dieppe, P.A.

    1981-01-01

    Fifteen patients with bilateral, symmetrical chronic pyrophosphate arthropathy of the knee were given intra-articular injections of yttrium-90 (5 mCi) plus steroid (triamcinolone hexacetonide, 20 mg) into one knee, and saline plus steroid into the other (control) knee. Allocation of the 90 Y injection was random and double blind. After 6 months there was significantly less pain, inactivity stiffness, joint-line tenderness, and effusion in the 90 Y-injected knees than in the controls (p 90 Y-injected and control knees in the changes in range of movement (p 90 Y may be of benefit in chronic pyrophosphate arthropathy, a disease for which there is no treatment. The predilection of this condition to affect the knees of the elderly makes such treatment highly suitable because the joint lends itself readily to injection and the procedure carries very few actual or potential risks in this age group. (author)

  18. Study of the chemical behaviour of technetium during irradiated fuels reprocessing

    International Nuclear Information System (INIS)

    Zelverte, A.

    1988-04-01

    This paper deals with the preparation of the lower oxidation states +III +IV and +V of technetium in nitric acid and its behaviour during the reprocessing of nuclear fuels (PUREX process). The first part of this work is a bibliographical study of this element in solution without any strong ligand. By chemical and electrochemical technics, pentavalent, tetravalent and trivalent technetium species, were prepared in nitric acid. The following chemical reactions are studied: - trivalent and tetravalent technetium oxidation by nitrate ion. - hydrazine and tetravalent uranium oxidation catalysed by technetium: in those reactions, we point out unequivocally the prominent part of trivalent and tetravalent technetium, - technetium behaviour towards hydroxylamine. Technetium should not cause any disturbance in the steps where hydroxylamine is employed to destroy nitrous acid and hydrazine replacement by hydroxylamine in uranium-plutonium partition could contribute to a best reprocessing of nuclear fuels [fr

  19. The chemical speciation of technetium in the environment: a literature survey

    International Nuclear Information System (INIS)

    Sparkes, S.T.; Long, S.E.

    1987-07-01

    This report reviews the current understanding of the chemical forms and behaviour of technetium in the environment. Technetium (VII) is the dominant species in most systems, however when reducing conditions arise technetium (IV) species predominate. Pertechnetate is a highly mobile ion in aqueous media and can exhibit significant environmental transfer. Technetium (IV) is readily sorbed by sediments and is able to complex with various ligands which subsequently determine its fate. Complexation with high molecular weight organic moieties reduces the availability of technetium although this is not necessarily the case with smaller molecules. In plants, technetium is absorbed as TcO 4 - and can become incorporated into organic molecules. The technetium present in such forms is generally considered less available for uptake by the ingesting animal than aqueous TcO 4 - , although significant transfer of this element has been reported from food into eggs. Areas of potential future interest are suggested. (author)

  20. Arabidopsis type I proton-pumping pyrophosphatase expresses strongly in phloem, where it is required for pyrophosphate metabolism and photosynthate partitioning.

    Science.gov (United States)

    Pizzio, Gaston A; Paez-Valencia, Julio; Khadilkar, Aswad S; Regmi, Kamesh; Patron-Soberano, Araceli; Zhang, Shangji; Sanchez-Lares, Jonathan; Furstenau, Tara; Li, Jisheng; Sanchez-Gomez, Concepcion; Valencia-Mayoral, Pedro; Yadav, Umesh P; Ayre, Brian G; Gaxiola, Roberto A

    2015-04-01

    Phloem loading is a critical process in plant physiology. The potential of regulating the translocation of photoassimilates from source to sink tissues represents an opportunity to increase crop yield. Pyrophosphate homeostasis is crucial for normal phloem function in apoplasmic loaders. The involvement of Arabidopsis (Arabidopsis thaliana) type I proton-pumping pyrophosphatase (AVP1) in phloem loading was analyzed at genetic, histochemical, and physiological levels. A transcriptional AVP1 promoter::GUS fusion revealed phloem activity in source leaves. Ubiquitous AVP1 overexpression (35S::AVP1 cassette) enhanced shoot biomass, photoassimilate production and transport, rhizosphere acidification, and expression of sugar-induced root ion transporter genes (POTASSIUM TRANSPORTER2 [KUP2], NITRATE TRANSPORTER2.1 [NRT2.1], NRT2.4, and PHOSPHATE TRANSPORTER1.4 [PHT1.4]). Phloem-specific AVP1 overexpression (Commelina Yellow Mottle Virus promoter [pCOYMV]::AVP1) elicited similar phenotypes. By contrast, phloem-specific AVP1 knockdown (pCoYMV::RNAiAVP1) resulted in stunted seedlings in sucrose-deprived medium. We also present a promoter mutant avp1-2 (SALK046492) with a 70% reduction of expression that did not show severe growth impairment. Interestingly, AVP1 protein in this mutant is prominent in the phloem. Moreover, expression of an Escherichia coli-soluble pyrophosphatase in the phloem (pCoYMV::pyrophosphatase) of avp1-2 plants resulted in severe dwarf phenotype and abnormal leaf morphology. We conclude that the Proton-Pumping Pyrophosphatase AVP1 localized at the plasma membrane of the sieve element-companion cell complexes functions as a synthase, and that this activity is critical for the maintenance of pyrophosphate homeostasis required for phloem function. © 2015 American Society of Plant Biologists. All Rights Reserved.

  1. Identification of Farnesyl Pyrophosphate and N-Arachidonylglycine as Endogenous Ligands for GPR92*S⃞

    OpenAIRE

    Oh, Da Young; Yoon, Jung Min; Moon, Mi Jin; Hwang, Jong-Ik; Choe, Han; Lee, Ju Yeon; Kim, Jae Il; Kim, Sunoh; Rhim, Hyewhon; O'Dell, David K.; Walker, J. Michael; Na, Heung Sik; Lee, Min Goo; Kwon, Hyuk Bang; Kim, Kyungjin

    2008-01-01

    A series of small compounds acting at the orphan G protein-coupled receptor GPR92 were screened using a signaling pathway-specific reporter assay system. Lipid-derived molecules including farnesyl pyrophosphate (FPP), N-arachidonylglycine (NAG), and lysophosphatidic acid were found to activate GPR92. FPP and lysophosphatidic acid were able to activate both Gq/11- and Gs-mediated signaling pathways, whereas NAG activated only the Gq/11-mediated signaling pathway. Co...

  2. Effect of mitomycin-c on biodistribution of 99 mTc-sodium pyrophosphate radiopharmaceuticals in mice; Efeito da mitomicina-c na biodistribuicao do radiofarmaco pirofosfato de sodio marcado com Tecnecio-99m em camundongos

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Maria L.; Braga, Ana C.S.; Gutfilen, Bianca; Bernardo-Filho, Mario [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)

    1997-12-01

    The desirable characteristics of technetium-99 have stimulated the development of labeling techniques for different molecular and cellular. It is generally acceptable that a variety of factors other than disease can alter the biodistribution of radiopharmaceutical and one such factor is the drug therapy. The absence of knowledge of these factors may result in an unexpected behavior of the radiopharmaceutical. Since patients on chemotherapeutic treatment ca be submitted, for different reasons, to a nuclear medicine procedure, we have studied in mice, the effect of mitomycin-C on the biodistribution of the radiopharmaceutical {sup 99m} Tc-pyrophosphate ({sup 99m} Tc-PYP). Mitomycin-C is an antineoplastic agent obtained from Streptomyces caesptosus. It was administered 0,15 mg of mitomycin-C in Balb/c in Balb/c female mice with an interval of 72 hours. After one hour of the last dose, 0.3 ml of {sup 99m} Tc-PYP (7.4 MBq) were injected after 0.5 h the animals were sacrificed. The organs were isolated, weighted and counted in a well counter. The percentages of radioactivity per gran of organs (% rad/g) were calculated and statistics analyses were performed (wilcoxon). The results have shown that the % rad/g has increased in pancreas, stomach, bone and lungs. These increased of radioactivity can be justified by the metabolic process or the therapeutic effect of mitomycin-C. (author). 8 refs., 2 tabs.

  3. Volatility literature of chlorine, iodine, cesium, strontium, technetium, and rhenium; technetium and rhenium volatility testing

    International Nuclear Information System (INIS)

    Langowski, M.H.; Darab, J.G.; Smith, P.A.

    1996-03-01

    A literature review pertaining to the volatilization of Sr, Cs, Tc (and its surrogate Re), Cl, I and other related species during the vitrification of Hanford Low Level Waste (LLW) streams has been performed and the relevant information summarized. For many of these species, the chemistry which occurs in solution prior to the waste stream entering the melter is important in dictating their loss at higher temperatures. In addition, the interactive effects between the species being lost was found to be important. A review of the chemistries of Tc and Re was also performed. It was suggested that Re would indeed act as an excellent surrogate for Tc in non-radioactive materials testing. Experimental results on Tc and Re loss from sodium aluminoborosilicate melts of temperatures ranging from 900--1350 degrees C performed at PNL are reported and confirm that Re behaves in a nearly identical manner to that of technetium

  4. Biogeochemical Controls on Technetium Mobility in Biogeochemical Controls on Technetium Mobility in FRC Sediments

    International Nuclear Information System (INIS)

    Lloyd, J.R.; McBeth, J.M.; Livens, F.R.; Bryan, N.D.; Ellis, B.; Sharma, H.; Burke, I.T.; Morris, K.

    2004-01-01

    Technetium-99 is a priority pollutant at numerous DOE sites, due to its long half-life (2.1 x 10 5 years), high mobility as Tc(VII) in oxic waters, and bioavailability as a sulfate analog. 99 Tc is far less mobile under anaerobic conditions, forming insoluble Tc(IV) precipitates. As anaerobic microorganisms can reduce soluble Tc(VII) to insoluble Tc(IV), microbial metabolism may have the potential to treat sediments and waters contaminated with Tc. Baseline studies of fundamental mechanisms of Tc(VII) bioreduction and precipitation (reviewed by Lloyd et al, 2002) have generally used pure cultures of metal-reducing bacteria, in order to develop conceptual models for the biogeochemical cycling of Tc. There is, however, comparatively little known about interactions of metal-reducing bacteria with environmentally relevant trace concentrations of Tc, against a more complex biogeochemical background provided by mixed microbial communities in the subsurface. The objective of this new NABIR project is to probe the site specific biogeochemical conditions that control the mobility of Tc at the FRC (Oak Ridge, TN). This information is required for the rational design of in situ bioremediation strategies for technetium-contaminated subsurface environments. We will use a combination of geochemical, mineralogical, microbiological and spectroscopic techniques to determine the solubility and phase associations of Tc in FRC sediments, and characterize the underpinning biogeochemical controls. A key strength of this project is that many of the techniques we are using have already been optimized by our research team, who are also studying the biogeochemical controls on Tc mobility in marine and freshwater sediments in the UK in a NERC funded companion study.

  5. Fluoridonitrosyl complexes of technetium(I) and technetium(II). Synthesis, characterization, reactions, and DFT calculations.

    Science.gov (United States)

    Balasekaran, Samundeeswari Mariappan; Spandl, Johann; Hagenbach, Adelheid; Köhler, Klaus; Drees, Markus; Abram, Ulrich

    2014-05-19

    A mixture of [Tc(NO)F5](2-) and [Tc(NO)(NH3)4F](+) is formed during the reaction of pertechnetate with acetohydroxamic acid (Haha) in aqueous HF. The blue pentafluoridonitrosyltechnetate(II) has been isolated in crystalline form as potassium and rubidium salts, while the orange-red ammine complex crystallizes as bifluoride or PF6(-) salts. Reactions of [Tc(NO)F5](2-) salts with HCl give the corresponding [Tc(NO)Cl4/5](-/2-) complexes, while reflux in neat pyridine (py) results in the formation of the technetium(I) cation [Tc(NO)(py)4F](+), which can be crystallized as hexafluoridophosphate. The same compound can be synthesized directly from pertechnetate, Haha, HF, and py or by a ligand-exchange procedure starting from [Tc(NO)(NH3)4F](HF2). The technetium(I) cation [Tc(NO)(NH3)4F](+) can be oxidized electrochemically or by the reaction with Ce(SO4)2 to give the corresponding Tc(II) compound [Tc(NO)(NH3)4F](2+). The fluorido ligand in [Tc(NO)(NH3)4F](+) can be replaced by CF3COO(-), leaving the "[Tc(NO)(NH3)4](2+) core" untouched. The experimental results are confirmed by density functional theory calculations on [Tc(NO)F5](2-), [Tc(NO)(py)4F](+), [Tc(NO)(NH3)4F](+), and [Tc(NO)(NH3)4F](2+).

  6. Detection of pulmonary hemorrhage with technetium-labeled red cells

    International Nuclear Information System (INIS)

    Winzelberg, G.G.; Laman, D.; Sachs, M.; Miller, W.H.

    1981-01-01

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung

  7. Coordination chemistry of technetium as related to nuclear medicine

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Richards, P.

    1982-01-01

    Significant advances have been made in the area of technetium coordination chemistry during the last five years. The main driving force behind this recent surge of interest in the field has been due to the practical application of technetium-99m in the rapidly growing speciality of nuclear medicine. Technetium-99 is one of the products of nuclear fission reactions, but it was the development of the molybdenum-99-technetium-99m generator about two decades ago that provided the basis for the development of radiopharmaceuticals routinely used in modern diagnostic applications. The chemistry of this element has proven to be quite rich owing to its multiple oxidation states and variable geometry. This can be attributed to its position in the middle of the periodic table. Diagnostic radiopharmaceuticals comprise predominantly III, IV and V oxidation states of Tc and involve a variety of coordination complexes. Even though the chemistry of Tc has been slow to evolve, recent synthetic advances have provided a more scientific basis for the study of a number of compounds with diverse coordination geometries and structures. Ligands with oxygen, nitrogen and sulfur donor atoms have been utilized to elucidate various aspects of the coordination chemistry of Tc. Single crystal X-ray structural analysis has been extensively used to characterize Tc complexes and thus construct a firm foundation for the study of synthetic and mechanistic aspects of the chemistry of this element. (author)

  8. Evaluation of reflux oesophagitis with technetium-99m-labelled ...

    African Journals Online (AJOL)

    Sucralfate binds with denuded protein to form a stable complex to protect the damaged mucosa. By utilising this property, technetium-99m-labelled sucraJfate can be used to demonstrate ulceration in the upper gastro-intestinal tract. Aim: The aim of this study was to evaluate 99mTc-labelled sucralfate in the diagnosis of ...

  9. Investigation on chemistry of model compounds of technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    Muenze, R.; Hartmann, E.

    1983-01-01

    The report summarized experimental and theoretical results concerning the chemical structures and the biodistribution of hydrophilic technetium chelates with hydroxycarboxylic and aminopolycarboxylic acids, thiol compounds and aliphatic and aromatic nitrogen compounds as ligands. Methods which are suitable for synthesizing and characterizing defined chelates of Tc(V), Tc(IV) and Tc(III) have been developed for crystlline substances and species in solution, respectively. For certain types of technetium chelates three dimensional structure models were calculated from atomic parameters. The electron energies and electron distribution of Tc(V) thiol compounds were calculated by quantum chemical methods in order to interprete physical properties of these substances. Biodistribution studies revealed relationships between the osteotropic behaviour and the structure of phosphorous and non-phosphorous technetium chelates and between the kidney uptake and ligand exchange ability of Tc(V) hydroxycarboxylates. Important parameters for the production of technetium-99m kits have been elaborated and used for the optimization of radiopharmaceuticals (bone-, kidney and hepatobiliaer agents). (author)

  10. Technetium and diazotrophic organisms: toxicity, localization, transfer factors

    International Nuclear Information System (INIS)

    Vandecasteele, C.M.; Delmotte, A.; Roucoux, P.; Hove, C. van

    1982-01-01

    Three diazotrophic organisms, together with one leguminous organism in symbiosis with one of them, were cultivated in the presence of various quantities of technetium, of which the localization, transfer factors and toxicity were studied in relation to the age of the organisms and their type of metabolism. The paper discusses the biochemical aspects of the results. (author)

  11. Membrane-based separation technologies for cesium, strontium, and technetium

    International Nuclear Information System (INIS)

    Kafka, T.

    1996-01-01

    This work is one of two parallel projects that are part of an ESP task to develop high-capacity, selective, solid extractants for cesium, strontium, and technetium from nuclear wastes. In this subtask, Pacific Northwest National Laboratory (PNNL) is collaborating with 3M, St. Paul, Minnesota, working in cooperation with IBC Advanced Technologies, American Fork, Utah

  12. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    1976-01-01

    A method of preparing improved technetium-99m labelled radiodiagnostic agents by reducing sup(99m)Tc-pertechnetate with stannous tartrate is given. Human serum albumine (HSA) and 1-hydroxyethylidene-1,1-disodiumphosphonate (HEDSPA), which are useful in scintigraphic examinations of the lung and bone, were labelled in this way

  13. Technetium: The First Radioelement on the Periodic Table

    Science.gov (United States)

    Johnstone, Erik V.; Yates, Mary Anne; Poineau, Frederic; Sattelberger, Alfred P.; Czerwinski, Kenneth R.

    2017-01-01

    The radioactive nature of technetium is discussed using a combination of introductory nuclear physics concepts and empirical trends observed in the chart of the nuclides and the periodic table of the elements. Trends such as the enhanced stability of nucleon pairs, magic numbers, and Mattauch's rule are described. The concepts of nuclear binding…

  14. Immobilization of technetium and nitrate in cement-based materials

    International Nuclear Information System (INIS)

    Tallent, O.K.; McDaniel, E.W.; Del Cul, G.D.; Dodson, K.E.; Trotter, D.R.

    1987-01-01

    The leachabilities of technetium and nitrate wastes immobilized in cement-based grouts have been investigated. Factors found to affect the leachabilities include grout mix ratio, grout fluid density, dry solid blend composition, and waste concentration. 10 refs., 7 figs., 3 tabs

  15. Technetium-99m ceftizoxime kit preparation

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento

    2005-01-01

    The aim of this work was to prepare a kit of 99 m Tc-ceftizoxime ( 99m Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99m Tc pertechnetate solution (Na 99m Tc O 4- ) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99m Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99m Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99 m Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99m Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ( 99m Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes. (author)

  16. Technetium-99m ceftizoxime kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento [Minas Gerais Univ. Federal, Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Martin-Comin, Josep [Bellvitge Univ., Barcelona (Spain)

    2005-10-15

    The aim of this work was to prepare a kit of {sup 99}m Tc-ceftizoxime ({sup 99m} Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium {sup 99m} Tc pertechnetate solution (Na {sup 99m} Tc O{sub 4-}) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the {sup 99m} Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of {sup 99m} Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for {sup 99}m Tc-CFT were 27.16 {+-} 0.23 and 27.17 {+-} 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 {+-} 0.33 and 29.43 {+-} 0.26, respectively. The results for the biodistribution of {sup 99m} Tc-CFT in infected animals furnished a ratio of 1.97 {+-} 0.31, 2.10 {+-} 0.42 and 2.01 {+-} 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ({sup 99m} Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with {sup 99m} technetium-labeled ceftizoxime for the

  17. Biosynthesis of monoterpenes. Stereochemistry of the enzymatic cyclizations of geranyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Wheeler, C.J.; Felton, N.M.

    1989-01-01

    The conversion of geranyl pyrophosphate to (+)-alpha-pinene and to (-)-beta-pinene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)- and to (+)-(3S)-linalyl pyrophosphate, respectively, and the subsequent cyclization of the anti, endo-conformer of these bound intermediates by mirror-image sequences which should result in the net retention of configuration at C1 of the geranyl precursor. Incubation of (1R)-[2-14C,1-3H]- and (1S)-[2-14C,1-3H]geranyl pyrophosphate with (+)-pinene cyclase and with (-)-pinene cyclase from common sage (Salvia officinalis) gave labeled (+)-alpha- and (-)-beta-pinene of unchanged 3H/14C ratio in all cases, and the (+)- and (-)-olefins were stereoselectively converted to (+)- and (-)-borneol, respectively, which were oxidized to the corresponding (+)- and (-)-isomers of camphor, again without change in isotope ratio. The location of the tritium was determined in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogens of these derived ketones. The results indicated that the configuration at C1 of the substrate was retained in the enzymatic transformations to the (+)- and (-)-pinenes, which is entirely consistent with the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate, transoid to cisoid rotation, and anti, endo-cyclization of the latter. The absolute stereochemical elements of the antipodal reaction sequences were confirmed by the selective enzymatic conversions of (3R)- and (3S)-1Z-[1-3H]linalyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene, respectively, and by the location of the tritium in the derived camphors as before. The summation of the results fully defines the overall stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to the antipodal pinenes

  18. Preoperative imaging in primary hyperparathyroidism. Role of thallium-technetium subtraction scintigraphy

    International Nuclear Information System (INIS)

    Foster, G.S.; Bekerman, C.; Blend, M.J.; Byrom, E.; Pinsky, S.M.

    1989-01-01

    Primary hyperparathyroidism, although often silent clinically, may lead to significant morbidity if it remains untreated. In more than 95% of all cases the cause is a parathyroid adenoma or glandular hyperplasia. Regression of disease follows successful surgical excision of the abnormal parathyroid gland. Recurrent or persistent hyperparathyroidism is most commonly caused by solitary adenomas, which may have an ectopic location. Preoperative localization of lesions may improve postoperative cure rates and decrease morbidity. Thallium T1 201 chloride-technetium Tc 99m pertechnetate subtraction scintigraphy was performed on 15 patients with primary hyperparathyroidism. The sensitivity and specificity for detection of abnormal glands were 90% and 95%, respectively. False-positive or false-negative results were minimize by strict adherence to a protocol and by the use of well-defined diagnostic criteria. Because of the superior sensitivity and specificity, this modality should be the primary imaging method of choice for preoperative evaluation of primary hyperparathyroidism. The relative role of other imaging modalities is also discussed. 31 references

  19. Studies on the mechanism of pyrophosphate-mediated uptake of iron from transferrin by isolated rat-liver mitochondria

    International Nuclear Information System (INIS)

    Konopka, K.; Romslo, I.; Bergen Univ.

    1981-01-01

    1. Respiring rat liver mitochondria accumulate iron released from transferrin by pyrophosphate. The amount of iron accumulated is 1-1.5 nmol mg protein -1 h -1 , or approximately 60% of the amount of iron mobilized from transferrin. 2. The uptake declines if respiration is inhibited, substrate is depleted, or the experiments are run under anaerobic conditions. Substrate, depletion and respiratory inhibitors are less inhibitory under anaerobic conditions. 3. More than 80% of the amount of iron accumulated by aerobic, actively respiring mitochondria can be chelated by bathophenanthroline sulphonate, and with deuteroporphyrin included, up to 30% of the amount of iron accumulated is recovered as deuteroheme. Iron accumulated by respiration-inhibited mitochondria under aerobic conditions is not available for heme synthesis. 4. With time the uptake of iron increases eightfold relative to the uptake of pyrophosphate. 5. The results are compatible with a model in which ferric iron is mobilized from transferrin by pyrophosphate, ferric iron pyrophosphate is bound to the mitochondria, iron is reduced, dissociates from pyrophosphate and is taken up by the mitochondria. Ferrous irons thus formed is available for heme synthesis. (orig.) [de

  20. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  1. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  2. Tooth - abnormal colors

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003065.htm Tooth - abnormal colors To use the sharing features on this page, please enable JavaScript. Abnormal tooth color is any color other than white to yellowish- ...

  3. Abnormal uterine bleeding

    Science.gov (United States)

    Anovulatory bleeding; Abnormal uterine bleeding - hormonal; Polymenorrhea - dysfunctional uterine bleeding ... ACOG committee opinion no. 557: Management of acute abnormal uterine bleeding in nonpregnant reproductive-aged women. Reaffirmed 2015. www. ...

  4. Method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions

    Science.gov (United States)

    Horwitz, E. Philip; Delphin, Walter H.

    1979-07-24

    A method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions containing these and other values by contacting the waste solution with an extractant of tricaprylmethylammonium nitrate in an inert hydrocarbon diluent which extracts the palladium and technetium values from the waste solution. The palladium and technetium values are recovered from the extractant and from any other coextracted values with a strong nitric acid strip solution.

  5. Potent inhibition of mammalian ribonucleases by 3', 5'-pyrophosphate-linked nucleotides.

    Science.gov (United States)

    Russo, N; Shapiro, R

    1999-05-21

    Molecular modeling based on the crystal structure of the complex of bovine pancreatic RNase A with the inhibitor 5'-diphosphoadenosine 3'-phosphate (ppAp) (Leonidas, D. D., Shapiro, R., Irons, L. I., Russo, N., and Acharya, K. R. (1997) Biochemistry 36, 5578-5588) was used to design new inhibitors that extend into unoccupied regions of the enzyme active site. These compounds are dinucleotides that contain an unusual 3',5'-pyrophosphate linkage and were synthesized in solution by a combined chemical and enzymatic procedure. The most potent of them, 5'-phospho-2'-deoxyuridine 3'-pyrophosphate, P' --> 5'-ester with adenosine 3'-phosphate (pdUppAp), binds to RNase A with Ki values of 27 and 220 nM at pH 5.9 and 7, respectively. These values are 6-9-fold lower than those for ppAp and 50-fold lower than that for the transition state analogue, uridine vanadate. pdUppAp has broad specificity; it is an effective inhibitor of at least two other members of the pancreatic RNase superfamily, human RNase-2 (eosinophil-derived neurotoxin) and RNase-4, which share only 36-44% sequence identity with the pancreatic enzyme. The potency of pdUppAp and the other inhibitors described here depends critically on the extended internucleotide linkage; the pyrophosphate group enhances dinucleotide binding to the three RNases by 2.1-2.9 orders of magnitude, as compared with a monophosphate. These data give further insight into the organization of the catalytic centers of the various RNases. Moreover, the new class of inhibitors provides a useful means by which to probe the biological actions of these and other related enzymes.

  6. Calcium pyrophosphate dihydrate crystal deposition disease presenting as a pseudotumor of the temporomandibular joint

    International Nuclear Information System (INIS)

    Vargas, A.; Teruel, J.; Pont, J.; Velayos, A.; Trull, J.; Lopez, E.

    1997-01-01

    We report a case of a 66-year-old white woman with calcium pyrophosphate dihydrate (CPPD) crystal deposition disease. The patient related a 2-month history of swelling with tenderness over the left pre-auricular region. A CT scan suggested a synovial chondromatosis. Surgical removal was done and histologic study showed CPPD crystals. This disease rarely involves the temporomandibular joint (TMJ) and is not usually considered in the differential diagnosis. To our knowledge, only 14 cases have been reported in the literature. (orig.)

  7. Rapid efflux of Ca2+ from heart mitochondria in the presence of inorganic pyrophosphate.

    Science.gov (United States)

    Vercesi, A; Lehninger, A L

    1984-01-13

    Inorganic pyrophosphate (PPi) in the intracellular concentration range causes rapid efflux of Ca2+ from rat heart mitochondria oxidizing pyruvate + malate in a low Na+ medium. Half-maximal rates of Ca2+ efflux were given by 20 microM PPi. During and after PPi-stimulated Ca2+ efflux the mitochondria retain their structural integrity and complete respiratory control. Carboxyatractyloside inhibits PPi-stimulated Ca2+ efflux, indicating PPi must enter the matrix in order to promote Ca2+ efflux. Heart mitochondria have a much higher affinity for PPi uptake and PPi-induced Ca2+ efflux than liver mitochondria.

  8. Detection of metastatic bone cancer by scintiscanning with sup(99m)Tc labelled sodium pyrophosphate

    International Nuclear Information System (INIS)

    Kromer, Bernard.

    1973-01-01

    Bone scanning with sup(99m)Tc sodium pyrophosphate was performed in 65 patients with primary neoplasms, using a gamma-camera. The scans are compared to those obtained with 85 Sr and 87 Sr. Sup(99m)Tc appears to be superior to the other two in the detection of metastatic bone lesions, mainly because of its physical characteristics (high yield of 140 KeV photons, short physical half-life). The advantages related to these characteristics are emphasized: possibility of rapid and systematic investigation of the whole skeleton using a gamma-camera; low dose irradiation of the patient which enables frequent repetitive studies to be performed [fr

  9. Gitelman syndrome disclosed by calcium pyrophosphate deposition disease: early diagnosis by ultrasonographic study

    Directory of Open Access Journals (Sweden)

    A. Zabotti

    2016-06-01

    Full Text Available Gitelman’s syndrome is a rare autosomal-recessive tubular disorder characterized by hypomagnesemia and hypocalciuria associated to hypokalemia. The clinical spectrum is wide and usually characterized by chronic fatigue, cramps, muscle weakness and paresthesiae. We describe a case of a 43 year-old male patient with early onset of knee arthritis and no other symptoms. Ultrasound revealed diffuse and confluent hyperechoic deposits in cartilage, fibrocartilage of the menisci and synovium and calcium pyrophosphate crystals were observed in the synovial fluid of the knee. The concomitant presence of hypomagnesemia, hypocalciuria and hypokalemia made clear the diagnosis of Gitelman’s syndrome associated with chondrocalcinosis.

  10. Scintigraphic diagnosis of acute nontransmural myocardial infarction using sup(99m)Tc-labelled pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Novak, J; Vizda, J; Kafka, P; Kubicek, J; Veverkova, O [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1980-04-01

    In 10 patients with acute non-transmural myocardial lesion, the heart muscle was examined by scintigraphy. The scan was negative in 4 patients, positive in 6. No obvious relationship was observed between the degree and character of sup(99m)Tc-pyrophosphate cumulation in the myocardial lesion and the results of other laboratory tests. The actual site of non-transmural lesion cannot be determined by scan. Although scintigraphy alone cannot decide whether a non-transmural necrosis or mere ischemic heart disease is involved, the method is a valuable addition to other diagnostic techniques presently in use.

  11. Computer assisted analysis of sup(99m)Tc pyrophosphate bone uptake in Paget's disease

    International Nuclear Information System (INIS)

    Maayan, M.L.; Eisenberg, J.; Volpert, E.; Shai, F.; Mroczek, R.

    1982-01-01

    The present clinical study describes a method of evaluation of Paget's disease bone by computer assisted analysis of activity curves obtained over normal and pathological portions of the skeleton in the same patient. The data obtained lead to a differential diagnosis between Paget's and metastatic disease of the bone, as well as an evaluation of subsequent therapy. The results indicate a higher bone activity, (expressed by bone flow and bone uptake, of sup(99m)Tc pyrophosphate) in Paget's than in metastatic disease of the bone, as well as a normalization of these parameters after prolonged therapy of Paget's patients with salmon calcitonin

  12. Bronchoalveolar lavage and technetium-99m glucoheptonate imaging in chronic eosinophilic pneumonia

    International Nuclear Information System (INIS)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    1984-01-01

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined

  13. Abdominal scanning with technetium-99m pertechnetate localizes ectopic gastric mucosa in the jejunum: case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Karakatsanis, K.G.; Chatzipavlidou, V. (Thessaloniki Univ. (Greece). Dept. of Nuclear Medicine); Zafiriadou, E. (Thessaloniki Univ. (Greece). 2. Dept. of Paediatric Surgery); Mavroudis, N. (Hippocrateion Hospital, Thessaloniki (Greece). Dept. of Diagnostic Radiology); Patsiaoura, K.; Gotzamani-Psarrakos, A. (Hippocrateion Hospital, Thessaloniki (Greece). Dept. of Pathology)

    1993-06-01

    A 16-year old male patient was admitted to hospital because of a fainting episode which was accompanied by diarrhoea that was dark red. All investigations were normal except a low haematocrit, a technetium-99m pertechnetate abdominal scan, which showed a large area of moderate activity in the upper left abdomen, and digital subtraction angiography, which showed bleeding in the same area where the abnormal finding on the pertechnetate scan was found. Ectopic gastric mucosa and a deep ulcer in an otherwise normal jejunum were found during the urgent exploratory laparotomy. (orig.).

  14. Method for radiolabeling proteins with technetium-99m

    International Nuclear Information System (INIS)

    Crockford, D.R.; Rhodes, B.A.

    1984-01-01

    In accordance with this invention, a substrate to be radiolabeled with technetium-99m is admixed with a buffered stannous chloride composition having a pH between about 4.5 and about 8.5 wherein the stannous chloride is produced from a non-oxidized tin source, the buffered stannous chloride is purged of oxygen and the buffer comprises a mixture of alkali metal biphthalate and an alkali metal tartrate. Alternatively, the buffer may include alkali metal borate or gentisate. The stannous chloride solution is admixed with the buffer and the resultant mixture is neutralized with sodium hydroxide. The neutralized solution then is admixed with the substrate eventually to be radiolabeled with technetium-99m. This solution is allowed to incubate for several hours (usually over 15 hours) in the absence of oxygen and at room temperature

  15. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  16. Preparation of a generator of technetium-99m

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    Practical description is given of equipment and operations necessary in the preparation of an isotopic generator of technetium-99m. The preparation and application of the active solution and throughly washed of the chromatographic column have been studied in order to allow molibdenum-99 to be adsorbed on a small band, and the solution of tectium-99m to be eluted with high efficiency and purity. The equipment and accesories used are easy and safety to manage, simplifying operations to be carried out with the active product, eliminating the sterile environment in the shielded cell, and facilitating the preparation of the solution of technetium-99m in sterile and pyrogen-free conditions.(author) [es

  17. Behavior of technetium in nuclear waste vitrification processes.

    Science.gov (United States)

    Pegg, Ian L

    Nearly 100 tests were performed with prototypical melters and off-gas system components to investigate the extents to which technetium is incorporated into the glass melt, partitioned to the off-gas stream, and captured by the off-gas treatment system components during waste vitrification. The tests employed several simulants, spiked with 99m Tc and Re (a potential surrogate), of the low activity waste separated from nuclear wastes in storage in the Hanford tanks, which is planned for immobilization in borosilicate glass. Single-pass technetium retention averaged about 35 % and increased significantly with recycle of the off-gas treatment fluids. The fraction escaping the recycle loop was very small.

  18. Physics of the missing atoms: technetium and promethium

    International Nuclear Information System (INIS)

    Aspden, H.

    1987-01-01

    Technetium (Z = 43) and promethium (Z = 61) are by far the least abundant of all atoms below the radioactive elements (Z = 84 onwards). Their scarcity confirms theoretical predictions emerging from a theory of the photon derived from synchronous lattice electrodynamics. This theory has given precise theoretical values for the fine-structure constant and the constant of gravitation G and is now shown in this paper to indicate resonant interactions between the vacuum lattice oscillations and technetium and promethium. In the case of promethium there is strong reason for believing that this atom can assume supergravitational or antigravitational properties, accounting for its scarcity. This paper not only adds support to the earlier theoretical work on the photon and gravitation, but suggests a research route that might lead to new technology based on controlled interactions with gravity fields

  19. Technetium labelled plasminogen activator - a potential reagent for thrombus detection

    Energy Technology Data Exchange (ETDEWEB)

    Paulsma-De Waal, J.H.; Boer, A.C. de; Cox, P.H.; Pillay, M.; Stassen, J.H.; Collen, D.

    1987-12-01

    The preparation of a technetium labelled plasminogen activator complex using a solid phase labelling technique is described. The labelled complex showed no significant loss of fibrinolytic activity in vitro and showed in vivo a rapid uptake in thrombi in an animal model and in human volunteer patients with known thrombi when injected into a vein draining to the thrombotic region. Systemic injection showed no uptake in the thrombi probably due to rapid sequestration of the complex by the liver.

  20. Overview of nuclear medicine and the role of technetium

    International Nuclear Information System (INIS)

    Eckelman, W.C.

    1987-01-01

    One of the driving forces for the elucidation of the chemistry of 99 Tc was the discovery of the Molybdenum Technetium generator. Since this generator system produces no-carrier-added 99 Tc, these studies at the nanomolar level mostly involve chromatography, and that analytical tool is then used to link the no-carrier added and carrier chemistry. These well-defined 99 Tc compounds are used in vivo to measure perfusion, but biochemical probes offer an exciting target for further exploration

  1. Effect of humic acid on sorption of technetium by alumina

    International Nuclear Information System (INIS)

    Kumar, S.; Rawat, N.; Kar, A.S.; Tomar, B.S.; Manchanda, V.K.

    2011-01-01

    Highlights: → Tc sorption on alumina has been studied under aerobic as well anaerobic condition over pH 3-10. → Effect of humic acid on sorption of Tc by alumina has been investigated. → Linear additive modeling and surface complexation modeling were carried out to delineate the role of humic acid in Tc(IV) sorption in ternary system of Tc(IV)-humic acid-alumina. → Sorption of humic acid onto alumina and strong complexation of Tc(IV) with humic acid were found to govern the sorption of Tc(IV) in the ternary system. - Abstract: Sorption of technetium by alumina has been studied in absence as well as in presence of humic acid using 95 Tc m as a tracer. Measurements were carried out at fixed ionic strength (0.1 M NaClO 4 ) under varying pH (3-10) as well as redox (aerobic and reducing anaerobic) conditions. Under aerobic conditions, negligible sorption of technetium was observed onto alumina both in absence and in presence of humic acid. However, under reducing conditions (simulated with [Sn(II)] = 10 -6 M), presence of humic acid enhanced the sorption of technetium in the low pH region significantly and decreased at higher pH with respect to that in absence of humic acid. Linear additive as well as surface complexation modeling of Tc(IV) sorption in presence of humic acid indicated the predominant role of sorbed humic acid in deciding technetium sorption onto alumina.

  2. Multi-organ technetium complexes production and use thereof

    International Nuclear Information System (INIS)

    Koehler, G.A.; Pestel, G.M.

    1976-01-01

    Chemical complexes, useful as radiopharmaceuticals, are formed by reacting technetium-99m with substituted or unsubstituted alkyl monophosphonic acids and certain ester derivatives thereof. The complexes are formed by reducing pertechnetate ion chemically or electrolytically in the presence of the phosphonic acid. By chemical modification of the phosphonic acid complexing agent, it is possible to ''tailor'' complexes for kidney, liver or bone imaging. The complexes are normally used in a physiologically acceptable aqueous medium. 20 Claims, No Drawings

  3. Molecular Engineering of Technetium and Rhenium Based Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zubieta, J.

    2003-01-01

    The research was based on the observation that despite the extraordinarily rich coordination chemistry of technetium and rhenium and several notable successes in reagent design, the extensive investigations by numerous research groups on a variety of N 2 S 2 and N 3 S donor type ligands and on HYNIC have revealed that the chemistries of these ligands with Tc and Re are rather complex, giving rise to considerable difficulties in the development of reliable procedures for the development of radiopharmaceutical reagents

  4. Mew organometallic complexes of technetium in different oxidation states

    International Nuclear Information System (INIS)

    Joachim, J.E.

    1993-09-01

    New organometallic compounds of Tc(I), Tc(III) and Tc(VII) were synthesized and their properties examined. These compounds were correlated with their homologous compounds of manganese and rhenium, which were also synthesized by the same route. The molecular and crystal structures of most technetium complexes and of the homologous complexes of manganese and rhenium were determined by single crystal X-ray diffraction. (orig.) [de

  5. Relationship between bone uptake of /sup 99m/Tc-pyrophosphate and hydroxyproline in blood and urine

    International Nuclear Information System (INIS)

    Wiegmann, T.; Kirsh, J.; Rosenthall, L.; Kaye, M.

    1976-01-01

    In a group of hospital patients with various diseases, the urinary hydroxyproline-to-creatinine ratio showed a significant correlation (r = 0.63; p is less than 0.001) with the 5-hr bone-to-soft-tissue ratio for /sup 99m/Tc-pyrophosphate uptake. In patients on chronic hemodialysis, a similar correlation was found between the 5-hr bone-to-soft-tissue ratio and hydroxyproline levels in plasma and serum. The findings suggest that /sup 99m/Tc-pyrophosphate binding by bone is related to collagen metabolism

  6. Thermal neutron cross section measurements for technetium-99

    International Nuclear Information System (INIS)

    Yates, M.A.; Schroeder, N.C.; Fowler, M.M.

    1993-01-01

    Technetium, because of its long half-like (213,000 years) and ability to migrate in the environment, is a primary contributor to the long-term radioactivity related risk associated with geologic nuclear waste disposal. One proposal for converting technetium to an environmentally benign element investigating transmutation with an accelerator-based system, (i.e., Accelerator Transmutation of Waste, ATW). Planning for efficient processing of technetium through the transmuter will require knowledge of the thermal neutron cross section for the 99 Tc (n,γ) 100 Tc reaction. The authors have recently remeasured this cross section. Weighed aliquots (19-205 μg) of a NIST traceable 99 Tc standard were irradiated for 30-150 sec using the pneumatic open-quotes rabbitclose quotes system of LANL's Omega West Reactor. The two gamma rays from the 15.7-sec half-life product were measured immediately after irradiation on a high-resolution Ge detector. Thermal fluxes were measured using gold foils and Cd wrapped gold foils. The observation cross section is 19 ± 1 b. This agrees well with the 1977 value but has half the uncertainty

  7. Non-Pertechnetate Technetium Sensor Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Crawford, Amanda D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Heineman, William R. [Univ. of Cincinnati, OH (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Branch, Shirmir D. [Univ. of Cincinnati, OH (United States)

    2014-09-01

    There remain several significant uncertainties in the understanding and modeling of the fate and speciation of 99Tc in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as a non-pertechnetate species that has not been identified and, based on experimentation to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetate species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work done in FY 2014 exploring the chemistry of a low-valence technetium species, [Tc(CO)3(H2O)3]+, a compound of interest due to its implication in the speciation of alkaline-soluble technetium in several Hanford tank waste supernatants. Progress made in FY 2014 was sponsored by the Department of Energy’s Office of Environmental Management and is summarized in this report.

  8. Technetium-99m ceftizoxime kit preparation

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT, with stability and biological activity preserved, able to identify a septic focus (E. coli in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL. After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4- with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli, the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.O objetivo deste trabalho foi preparar um kit de Tc

  9. Method of preparation of technetium-99m labelled radio-diagnostic agents and a stable non radio-active carrier

    International Nuclear Information System (INIS)

    1975-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents is described by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  10. High pressure liquid chromatographic assay of technetium in solutions of sodium pertechnetate produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1985-12-01

    High pressure liquid chromatography (HPLC) is used for the assay of nanogram quantities of technetium and to determine technetium in decayed pharmaceutical products, derived from three methods of manufacture. These methods of manufacture give comparably low levels of technetium-99, at the time of collection of the solution. However, when the solutions are used to produce ready-to-inject technetium-99m, high levels of technetium-99 are present at the time of calibration, which is the day after the collection date. Where sensitive reagent kits are to be labelled, freshly collected solutions of technetium-99m should be used. The HPLC assay is a valuable technique for the quality control of technetium-based radiopharmaceuticals, and for investigation of methods of manufacture of technetium-99m. Experimental studies confirmed the findings of previous workers

  11. Experimental substantiation of myocardial affection visualization by means of pyrophosphate-sup(99m)Tc

    Energy Technology Data Exchange (ETDEWEB)

    Shepeleva, I I; Saprygin, D B; Saks, V A; Kramer, A A; Kashtelyan, L S [Akademiya Meditsinskikh Nauk SSSR, Moscow. Vsesoyuznyj Kardiologicheskij Nauchnyj Tsentr; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Serdechno-Sosudistoj Khirurgii)

    1979-03-01

    To study the mechanisms of accumulation of the pyrophosphate-sup(99m)TcSn complex a model of an isolated rat heart perfused according to Langendorf under conditions was used. The results of the experiment showed that intensive accumulation of the radionuclide in the myocardium began already at the first minutes of anoxia, i.e. at the stage of reversible changes when reoxygenation brought about a drop in the level of accumulated radioactivity down to the normal limit. Anoxia lasting for 5 minutes led to a 10 per cent accumulation of the entire dose of radioactivity in the myocardium, that lasting for 10 minutes-up to 18 per cent. As a result of a 5-minute reoxygenation after a 10-minute anoxia the level of accumulated radioactivity fell down to 4-5 per cent. Reoxygenation after s 20-30-minute anoxia produced no effect on the curve of the radionuclide accumulation in the heart. Alongside radiometric studies the content of macroergs (ATP and creatine phosphate) in the norm and in development of anoxia was determined. The accumulation of the pyrophosphate-sup(99m)TcSn complex in the myocardial cells is closely connected with energy metabolism of the cell and, is apparently, caused by changes in the cell membrane permeability by this complex.

  12. Comparison of pyrophosphate and gluconate scan of dog hearts with experimental cardiomyopathy

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Kafka, P.; Kubicek, J.; Vizda, J.; Mazurova, Y.; Veverkova, O.

    1983-01-01

    High intravenous doses of theophylline with adrenalin were used to produce experimental cardiomyopathy in dogs. This damage was visualized scintigraphically using either sup(99m)Tc-pyrophosphate (10 dogs) or sup(99m)Tc-gluconate (another 10 dogs). Scintigraphic examinations using sup(99m)Tc-pyrophosphate were carried out 48 hours after the damage had developed: in two dogs the examination was negative, in two cases boundary, in 6 cases the scintigraphic finding was clearly positive. sup(99m)Tc-gluconate was used in the examination of 5 animals four hours after the damage had developed. In this case the scan was significantly positive in all cases. The gluconate scan was made 24 hours after damage, again in 5 dogs. Here the positive change was less explicit, in one case the finding was negative. Histological examination of the affected myocardium showed in all cases a very light damage, in many instances on the limit of resolution by light microscopy. The findings were always degenerative (dystrophic) changes and microcirculation disorders without any necrosis. The work showed that both studied radiopharmaceutical preparations are a very sensitive but nonspecific indicator of non-ischemic disorders of the myocardium. For sup(99m)Tc-gluconate this is an original finding. (author)

  13. Use of pyrophosphate-/sup 99m/Tc in diagnosis of malignant tumors of bones

    Energy Technology Data Exchange (ETDEWEB)

    Kasatkin, Yu N; Purizhanskii, I I; Survila, Z P; Agranat, V Z; Korsunskii, V N

    1976-10-01

    Pyrophosphate-/sup 99m/Tc was administered intravenously in a dose of 0.05 to 0.08 mCi per 1 kg body weight of the patient. Studies were made after 4, 6, and 24 hours with fixed and movable detectors. During investigations a gamma-chamber magnetic memory and a 4096-channel analyzer were also used. A quantitative processing of the material was made. The authors determined distribution of the preparation in normal and pathological bone tissue. A total of 142 patients with tumors of the bone tissue were examined; 858 radioisotope measurements were made. An analysis of accumulation of pyrophosphate-/sup 99m/Tc in primary osteogenic tumors in systemic affections of the bones and bone metastases was made. There is a relation between the concentration of the radiopharmaceutical preparation and the morphological structure of the tumor. Reduction in the accumulation of the radioactive indicator took place after radiation and medicinal effect, this made it possible to judge the regression of the tumor.

  14. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho [Dept. of Radiology, Saga Medical School (Japan); Matsui, Makoto; Kuroda, Yasuo [Dept. of Neurology, Saga Medical School (Japan)

    2001-12-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  15. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    International Nuclear Information System (INIS)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho; Matsui, Makoto; Kuroda, Yasuo

    2001-01-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  16. Plant abnormality inspection device

    International Nuclear Information System (INIS)

    Takenaka, Toshio.

    1990-01-01

    The present invention concerns a plant abnormality inspection device for conducting remote or automatic patrolling inspection in a plant and, more particularly, relates to such a device as capable of detecting abnormal odors. That is, the device comprises a moving device for moving to a predetermined position in the plant, a plurality of gas sensors for different kind of gases to be inspected mounted thereon, a comparator for comparing the concentration of a gas detected by the gas sensor with the normal gas concentration at the predetermined position and a judging means for judging the absence or presence of abnormality depending on the combination of the result of the comparison and deliverying a signal if the state is abnormal. As a result, a slight amount of gas responsible to odors released upon abnormality of the plant can be detected by a plurality of gas sensors for different kinds gases to rapidly and easily find abnormal portions in the plant. (I.S.)

  17. ASSESSMENT OF TECHNETIUM LEACHABILITY IN CEMENT-STABILIZED BASIN 43 GROUNDWATER BRINE

    International Nuclear Information System (INIS)

    Duncan, J.B.; Cooke, G.A.; Lockrem, L.L.

    2009-01-01

    This report documents the effort to sequester technetium by the use of getters, reductants (tin(II) apatite and ferrous sulfate), sorbents (A530E and A532E ion exchange resins), and cementitious waste form. The pertechnetate form of technetium is highly soluble and mobile in aerobic (oxidizing) environments.

  18. Determination of Technetium-99 in Environmental Samples by Solvent Extraction at Controlled Valence

    DEFF Research Database (Denmark)

    Chen, Q.J.; Aarkrog, A.; Dahlgaard, H.

    1989-01-01

    Distribution coefficients of technetium and ruthenium are determined under different conditions with CCl4, cyclohexanone, and 5% tri-isooctylamine (TIOA)/xylene. A method for analyzing 99Tc in environmental samples has been developed by solvent extraction in which the valences of technetium...

  19. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  20. Ligand-free, protein-bound technetium-99m. Evidence for tumour localisation

    International Nuclear Information System (INIS)

    Jakovljevic, A.C.; Pojer, P.M.

    1984-11-01

    An hypothesis that cations accumulate in tumours independent of ligand is tested. A preparation of technetium-99m known to be ligand-free (that is, the technetium is protein bound and no other ligand is injected) has been shown to accumulate in a T-cell lymphoma

  1. Tumoral calcium pyrophosphate dihydrate deposition disease with bone destruction in the shoulder. CT an MR findings in two cases

    International Nuclear Information System (INIS)

    Mizutani, H.; Ohba, S.; Sasaki, S.; Ando, K.; Mizutani, M.; Matsushita, Y.; Ohtsuka, T.; Terazawa, T.; Ijima, S.

    1998-01-01

    We report on specific CT and MR features in two cases of tumoral calcium pyrophosphate dihydrate deposition disease in the shoulder with unusually large tumors. CT revealed features that were specific to the disease. MR was useful for detecting the extent of the mass and for obtaining information on adjacent soft-tissue and bone-marrow changes. (orig.)

  2. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Khalkhali, I.; Diggles, L. E.; Cutrone, J. A.; Mishkin, F. S. [Los Angeles Medical Center, Torrance (United States). Dept. of Radiology; Iraniha, S. [Los Angeles Medical Center, Torrance (United States). Surgery

    1997-09-01

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992.

  3. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    International Nuclear Information System (INIS)

    Khalkhali, I.; Diggles, L. E.; Cutrone, J. A.; Mishkin, F. S.; Iraniha, S.

    1997-01-01

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992

  4. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  5. Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Pons, F.; Vidal-Sicart, S.; Fuster, D.; Herranz, R.; Torregrosa, J.V.; Sabater, L.; Fernandez-Cruz, L.

    1997-01-01

    Technetium-99m sestamibi scintigraphy has become a valuable tool in locating parathyroid glands in patients with primary hyperparathyroidism. The aim of this study was to evaluate its usefulness in secondary hyperparathyroidism. Twenty patients were injected intravenously with 740 MBq of 99m Tc-sestamibi and images were obtained at 15 min and 2 h post injection. All patients underwent parathyroid ultrasonography (US) as well as bilateral surgical neck exploration and 64 parathyroid glands were removed. US revealed at least one enlarged gland in 15/20 patients (75%), while 99m Tc-sestamibi scintigraphy showed focal areas of increased uptake in at least one gland in 17/20 patients (85%). When imaging results for all glands were evaluated according to surgical results, sensitivity was 54% for parathyroid scintigraphy and 41% for US, and specificity was 89% for both imaging techniques. There was a discrepancy between the two imaging modalities in 28 glands (35%). The mean surgical weight of US-positive glands (1492±1436 mg) was significantly higher than that of US-negative glands (775±703 mg) (P 99m Tc-sestamibi scintigraphy are complementary imaging techniques in the preoperative localization of abnormal parathyroid glands in patients with secondary hyperparathyroidism. The limited sensitivity of the techniques means that patients will still require bilateral neck exploration; therefore routine preoperative parathyroid scanning in renal patients is not justified. (orig.)

  6. The Evaluation of Novel Tin Materials for the Removal of Technetium from Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Kent E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wellman, Dawn M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-06-30

    Technetium-99 (99Tc) is present at several U.S. Department of Energy (DOE) facilities, including the Hanford, Oak Ridge, Paducah, Portsmouth, and Savannah River sites. Due to its mobility, persistence, and toxicity in the environment, developing means to immobilize and/or remove technetium from the environment is currently a top priority for DOE. However, there are currently very few approaches that effectively manage the risks of technetium to human health and the environment. The objective of this study is to evaluate novel synthetic materials that could enable direct removal of technetium from groundwater. The following report •assesses the viability of existing methodologies for synthesis of tin (II) apatite for in situ formation and remediation of 99Tc within the subsurface environment •discusses the development of alternative methodologies for production of tin (II) apatite •evaluates nanoporous tin phosphate materials for removal of technetium from groundwater.

  7. Clearance of technetium-99m-DTPA and HRCT findings in the evaluation of patients with Idiopathic Pulmonary Fibrosis

    Directory of Open Access Journals (Sweden)

    Karkavitsas Nikolaos

    2006-02-01

    Full Text Available Abstract Background Clearance of inhaled technetium-labeled diethylenetriamine pentaacetate (99mTc-DTPA is a marker of epithelial damage and an index of lung epithelial permeability. The aim of this study was to investigate the role of 99mTc-DTPA scan in patients with Idiopathic Pulmonary Fibrosis (IPF. Our hypothesis is that the rate of pulmonary 99mTc-DTPA clearance could be associated with extent of High Resolution Computed Tomography (HRCT abnormalities, cell differential of bronchoalveolar lavage fluid (BALF and pulmonary function tests (PFTs in patients with IPF. Methods We studied prospectively 18 patients (14 male, 4 female of median age 67yr (range 55–81 with histologically proven IPF. HRCT scoring included the mean values of extent of disease. Mean values of these percentages represented the Total Interstitial Disease Score (TID. DTPA clearance was analyzed according to a dynamic study using a Venticis II radioaerosol delivery system. Results The mean (SD TID score was 36 ± 12%, 3 patients had mild, 11 moderate and 4 severe TID. Abnormal DTPA clearance half-time (t1/2 Conclusion Our data suggest that 99mTc-DTPA lung scan is not well associated with HRCT abnormalities, PFTs, and BALF cellularity in patients with IPF. Further studies in large scale of patients are needed to define the role of this technique in pulmonary fibrosis.

  8. Defining Abnormally Low Tenders

    DEFF Research Database (Denmark)

    Ølykke, Grith Skovgaard; Nyström, Johan

    2017-01-01

    The concept of an abnormally low tender is not defined in EU public procurement law. This article takes an interdisciplinary law and economics approach to examine a dataset consisting of Swedish and Danish judgments and verdicts concerning the concept of an abnormally low tender. The purpose...

  9. Investigations on the structures of sup(99m)Tc and 113Sn pyrophosphate complexes and of sup(99m)Tc and 113Sn ethane hydroxy diphosphate complexes

    International Nuclear Information System (INIS)

    Hohloch, M.

    1980-01-01

    The complex formation of double labelling of bivalent 113 Sn and reduced, quadrovalent sup(99m)Tc with pyrophosphate (PPi) or ethane hydroxy diphosphorate (EHDP) has been investigated by means of in vivo distribution in the rat. The molar rates of sup(99m)Tc and 113 Sn to PPi resp. EHDP, as well as the pH-value and the initial concentration is varied. Furthermore, both elements were oxidized with H 2 O 2 in the alkaline medium. Four typical sup(99m)Tc and two typical 113 Sn in-vivo distribution patterns can be differentiated: 1. Pertechnetate, characterized by a strong enrichment in the stomach, forms when all Sn-II has been oxidized to Sn-IV in the preparation. 2. One bone-seeking 113 Sn-II PPi (EHDP) complex and a sup(99m)Tc-IV PPi (EHDP) complex each, which are formed at least equimolar ratio of Sn to PPi (EHDP) and suffiently high concentration of PPi (EHDP) in the physiological pH-value. 3. A non-bone-seeking sup(99m)Tc-IV compound, which is enriched in the kidneys instead, is formed in the weakly alkaline medium or at low PPi (EHDP) concentration. This is probably monomeric technetium dioxide dihydrate. 4. A sup(99m)Tc as well as a Sn colloid is formed at deficient ligand concentration (PPi or EHDP to Sn). The chemical composition of the complexes is discussed the possible reaction courses are illustrated in the following diagrams. (orig./MG) [de

  10. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  11. Non-pertechnetate Technetium Sensor Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Branch, Shirmir D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Univ. of Cincinnati, OH (United States); Lines, Amanda M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Heineman, William R. [Univ. of Cincinnati, OH (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-03-24

    Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 (99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetate species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO)3(H2O)3]+, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.

  12. Technetium and neptunium reactions in basalt/groundwater systems

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Kelmers, A.D.; Kessler, J.H.; Clark, R.J.; Johnson, J.S. Jr.; Young, G.C.; Case, F.I.; Westmoreland, C.G.

    1985-01-01

    Sorption isotherms and apparent concentration limits for Tc(VII) and Np(V) for a variety of groundwater/basalt systems were determined using Grande Ronde basalt samples representative of the Hanford Site candidate high-level waste repository. Under oxic redox conditions (air present), little or no sorption of technetium was observed; neptunium exhibited low to moderate sorption ratios. Under anoxic redox conditions (oxygen-free), low to moderate sorption of technetium was often observed, but the extent of sorption was highly dependent upon the groundwater composition and the method of pretreatment (if any) of the basalt. Sorption isotherms for technetium under reducing redox conditions (hydrazine added) indicate an apparent concentration limit of approximately 10 -6 mol/l Tc. No apparent concentration limit was found for neptunium for concentrations in groundwater up to 10 -6 mol/l and 8 x 10 -7 mol/l under oxic and reducing (hydrazine added) redox conditions, respectively. Valence control and valence analysis experiments suggest that the sorption or precipitation of Tc and Np from groundwater in the presence of basalt may result from a heterogeneous reaction occurring on the surface of the basalt. One of the critical factors of this reduction reaction appears to be the accessibility of the reactive ferrous iron component of the basalt. The laboratory simulation of groundwater redox conditions representative of the repository environment through the use of solution phase redox reagents is of questionable validity, and information obtained by such experimental methods may not be defensible for site performance assessment calculations. Anoxic experiments conducted in an argon-filled glove box appear better suited for the laboratory simulation of in situ redox conditions. 15 references, 6 figures

  13. Technetium and neptunium reactions in basalt/groundwater systems

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Kelmers, A.D.; Kessler, J.H.; Clark, R.J.; Johnson, J.S. Jr.; Young, G.C.; Case, F.I.; Westmoreland, C.G.; Florida State Univ., Tallahassee)

    1984-01-01

    Sorption isotherms and apparent concentration limits for Tc(VII) and Np(V) for a variety of groundwater/basalt systems were determined using Grande Ronde basalt samples representative of the Hanford Site candidate high-level waste repository. Under oxic redox conditions (air present), little or no sorption of technetium was observed; neptunium exhibited low to moderate sorption ratios. Under anoxic redox conditions (oxygen-free), low to moderate sorption of technetium was often observed, but the extent of sorption was highly dependent upon the groundwater composition and the method of pretreatment (if any) of the basalt. Sorption isotherms for technetium under reducing redox conditions (hydrazine added) indicate an apparent concentration limit of approximately 10 -6 mol/L Tc. No apparent concentration limit was found for neptunium for concentrations in groundwater up to approx. 10 -6 mol/L and 8 x 10 -7 mol/L under oxic and reducing (hydrazine added) redox conditions, respectively. Valence control and valence analysis experiments suggest that the sorption or precipitation of Tc and Np from groundwater in the presence of basalt may result from a heterogeneous reaction occurring on the surface of the basalt. One of the critical factors of this reduction reaction appears to be the accessibility of the reactive ferrous iron component of the basalt. The laboratory simulation of groundwater redox conditions representative of the repository environment through the use of solution phase redox reagents is of questionable validity, and information obtained by such experimental methods may not be defensible for site performance assessment calculations. Anoxic experiments conducted in an argon-filled glove box appear better suited for the laboratory simulation of in situ redox conditions. 15 refs., 6 tabs

  14. Can aquatic macrophytes mobilize technetium by oxidizing their rhizosphere?

    International Nuclear Information System (INIS)

    Sheppard, S.C.; Evenden, W.G.

    1991-01-01

    Technetium (Tc) is very mobile in aerated surface environments, but is essentially immobile and biologically unavailable in anaerobic sediments. Aquatic macrophyte roots penetrate anaerobic sediments, carrying O 2 downward and frequently creating oxidizing conditions in their rhizosphere. The authors hypothesized that this process could mobilize otherwise unavailable Tc, possibly leading to incorporation of Tc into human or animal foods. Through experiments with rice (Oryza sativa L.), and with a novel artificial macrophyte root, they concluded that this pathway is unlikely to be important for annual plants, especially in soils with a high biological oxygen demand. The relatively slow oxidation of Tc limited its mobilization by short-lived root systems

  15. Technetium scanning in Kaposi's sarcoma and its simulators

    International Nuclear Information System (INIS)

    Gunnoe, R.; Kalivas, J.

    1982-01-01

    The clinical picture of ulcerated purple plaques on the legs often suggests several diagnoses: Kaposi's sarcoma, stasis dermatitis, atrophie blanche (livedoid vasculitis), and a poorly understood condition called acroangiodermatitis of Favre-Chaix (pseudo-Kaposi's sarcoma). Even the skin biopsy may not always be conclusive. We describe our experience with three patients with pseudo-Kaposi's sarcoma, one with true Kaposi's sarcoma and two with atrophie blanche. Clinical and histopathologic similarities among these three conditions pointed up the need for additional confirmatory studies, i.e., isotope scanning. The technetium scan was positive in both Kaposi's sarcoma and pseudo-Kaposi's sarcoma but negative in atrophie blanche

  16. Experimental study and quality control of a technetium-99 generator

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    The performarce of a generator of technetium-99m to be used in nuclear medicine is studied. The most interesting characteristic of this generator is the use of a U-shaped chromatographuc column so as to improve its efficiency and design without increasing the weight of its shield. With the aim of improving certain aspects of the generator, molibdenum-99 was applied to adecuate pH, pirogens were removed from the column set up before application, application was effected on a dry column, the smallest alumina particles were separated on the column, etc. The most important parameters of an isotopic generator are studied, and the corresponding quality controls performed. (author)

  17. Environmental behavior of technetium-99 and iodine-129

    International Nuclear Information System (INIS)

    Garland, T.R.; Schreckhise, R.G.

    1982-01-01

    The environmental behavior of technetium-99 and iodine-129 was once thought to be similar, particularly with respect to their soil solubility and biological interactions. Over the past several years, the comparative behavior of these two anions has been studied with respect to their fate in natural environments (both aquatic and terrestrial). The mechanisms studied include physical, chemical and biological parameters that account for differences in soil behavior, cycling between soil and/or air to vegetation, adsorption and metabolism in plants, and their availability and fate following ingestion by animals

  18. Mass spectral analysis of cationic and neutral technetium complexes

    International Nuclear Information System (INIS)

    Unger, S.E.; McCormick, T.J.; Nunn, A.N.; Treher, E.N.

    1986-01-01

    Cationic and neutral technetium compounds have been characterized by mass spectrometry using a variety of ionization methods. These compounds include octahedral cationic complexes containing phosphorous and arsenic ligands such as DIPHOS and DIARS and neutral complexes containing PnAO and dimethylglyoxime, DMG, or cyclohexanedione dioxime, CDO, ligands. Boronate esters incorporating methyl and butyl derivatives of the DMG and CDO dioximes represent a new class of seven-coordinate Tc radiopharmaceuticals whose characterization by mass spectrometry has not previously been described. These complexes show promise as myocardial imaging agents. (author)

  19. Pyrophosphate synthesis in iron mineral films and membranes simulating prebiotic submarine hydrothermal precipitates

    Science.gov (United States)

    Barge, Laura M.; Doloboff, Ivria J.; Russell, Michael J.; VanderVelde, David; White, Lauren M.; Stucky, Galen D.; Baum, Marc M.; Zeytounian, John; Kidd, Richard; Kanik, Isik

    2014-03-01

    Cells use three main ways of generating energy currency to drive metabolism: (i) conversion of adenosine diphosphate (ADP) to adenosine triphosphate (ATP) by the proton motive force through the rotor-stator ATP synthase; (ii) the synthesis of inorganic phosphate˜phosphate bonds via proton (or sodium) pyrophosphate synthase; or (iii) substrate-level phosphorylation through the direct donation from an active phosphoryl donor. A mechanism to produce a pyrophosphate bond as “energy currency” in prebiotic systems is one of the most important considerations for origin of life research. Baltscheffsky (1996) suggests that inorganic pyrophosphate (PO74-; PPi) may have preceded ATP/ADP as an energy storage molecule in earliest life, produced by an H+ pyrophosphatase. Here we test the hypothesis that PPi could be synthesized in inorganic precipitates simulating hydrothermal chimney structures transected by thermal and/or ionic gradients. Appreciable yields of PPi were obtained via substrate phosphorylation by acetyl phosphate within the iron sulfide/silicate precipitates at temperatures expected for an alkaline hydrothermal system. The formation of PPi only occurred in the solid phase, i.e. when both Pi and the phosphoryl donor were precipitated with Fe-sulfides or Fe-silicates. The amount of Ac-Pi incorporated into the precipitate was a significant factor in the amount of PPi that could form, and phosphate species were more effectively incorporated into the precipitate at higher temperatures (⩾50 to >85 °C). Thus, we expect that the hydrothermal precipitate would be more enriched in phosphate (and especially, Ac-Pi) near the inner margins of a hydrothermal mound where PPi formation would be at a maximum. Iron sulfide and iron silicate precipitates effectively stabilized Ac-Pi and PPi against hydrolysis (relative to hydrolysis in aqueous solution). Thus it is plausible that PPi could accumulate as an energy currency up to useful concentrations for early life in a

  20. Study of irradiated bone: Part III. /sup 99m/Tc pyrophosphate autoradiographic changes

    International Nuclear Information System (INIS)

    King, M.A.; Corriveau, O.; Casarett, G.W.; Weber, D.A.

    1978-01-01

    The macroautoradiographic and microautoradiographic localization of /sup 99m/Tc-pyrophosphate (/sup 99m/TcPPi) was studied in x-irradiated bone of rabbits up to one year post-irradiation. In cortical bone, /sup 99m/TcPPi was concentrated on bone surfaces near vasculature. Both forming and resorbing bone surfaces were comparably labeled at 2 hrs post-injection. Uptake on the surface of sites of haversian bone remodeling was observed to be at least part of the increased /sup 99m/TcPPi observed in irradiated bone in camera images. In irradiated trabecular bone 12 months following irradiation, a patchy decrease in /sup 99m/TcPPi uptake was correlated with localized decreases in vasculature

  1. The effect of preparation method on the proton conductivity of indium doped tin pyrophosphates

    DEFF Research Database (Denmark)

    Anfimova, Tatiana; Lie-Andersen, T.; Jensen, E. Pristed

    2015-01-01

    Indium doped tin pyrophosphates were prepared by three synthetic routes. A heterogeneous synthesis from metal oxides with excess phosphoric acid produces crystalline phosphate particles with a phosphorus rich amorphous phase along the grain boundaries. The amorphous phase prevents the agglomeration...... decrease in conductivity as well as significant agglomeration of the particles, as evident in TEM and from particle size distribution measurements. Homogeneous synthesis with soluble metal acetates or chlorides as precursors results in a single crystalline phase with a small particle size, but strongly...... agglomerated, and a low conductivity at 10- 7-10- 6 Scm- 1 level. Further impregnation of the agglomerates with phosphoric acid does not lead to formation of the phosphorus rich amorphous layers on the surface of the crystals. An intermediate conductivity of 10- 3 Scm- 1 was observed for the acid treated...

  2. Prognosis of ischemic heart disease based on pyrophosphate scan of myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1982-11-01

    A brief survey is given of the present knowledge of the problems, based on literary data. Pyrophosphate myocardial scan is an important examination in establishing the diagnosis of acute myocardial infarction and some other myocardial diseases. Apart from this, it is of great importance in determining the prognosis. In the early phase of the disease, an apparently worse prognosis is found in patients with extensive lesion, and in those with an infarction intensively accumulating the radiopharmaceutical. In a certain number of infarctions, scintigraphic examination is positive over several months; usually the radiopharmaceutical disappears within two weeks. Patients with long-persisting positivity have a markedly worse prognosis. On the basis of early and late heart scan, it is thus possible to estimate the future fate of patients w+th ischemic heart disease. Large and long-persisting lesions serve as a warning for the physician.

  3. Identification of monoclinic calcium pyrophosphate dihydrate and hydroxyapatite in human sclera using Raman microspectroscopy.

    Science.gov (United States)

    Chen, Ko-Hua; Li, Mei-Jane; Cheng, Wen-Ting; Balic-Zunic, Tonci; Lin, Shan-Yang

    2009-02-01

    Raman microspectroscopy was first used to determine the composition of a calcified plaque located at the pterygium-excision site of a 51-year-old female patient's left nasal sclera after surgery. It was unexpectedly found that the Raman spectrum of the calcified sample at 1149, 1108, 1049, 756, 517, 376 and 352/cm was similar to the Raman spectrum of monoclinic form of calcium pyrophosphate dihydrate (CPPD) crystal, but differed from the Raman spectrum of triclinic form of CPPD. An additional peak at 958/cm was also observed in the Raman spectrum of the calcified plaque, which was identical to the characteristic peak at 958/cm of hydroxyapatite (HA). This is the first study to report the spectral biodiagnosis of both monoclinic CPPD and HA co-deposited in the calcified plaque of a patient with sclera dystrophic calcification using Raman microspectroscopy.

  4. Partial oxidation of D-xylose to maleic anhydride and acrylic acid over vanadyl pyrophosphate

    International Nuclear Information System (INIS)

    Ghaznavi, Touraj; Neagoe, Cristian; Patience, Gregory S.

    2014-01-01

    Xylose is the second most abundant sugar after glucose. Despite its tremendous potential to serve as a renewable feedstock, few commercial processes exploit this resource. Here, we report a new technology in which a two-fluid nozzle atomizes a xylose-water solution into a capillary fluidized bed operating above 300 °C. Xylose-water droplets form at the tip of the injector, vaporize then react with a heterogeneous mixed oxide catalyst. A syringe pump metered the solution to the reactor charged with 1 g of catalyst. Product yield over vanadyl pyrophosphate was higher compared to molybdenum trioxide-cobalt oxide and iron molybdate; it reached 25% for maleic anhydride, 17% for acrylic acid and 11% for acrolein. Gas residence time was 0.2 s. The catalyst was free of coke even after operating for 4 h – based on a thermogravimetric analysis of catalyst withdrawn from the reactor. Below 300 °C, powder agglomerated at the tip of the injector at 300 °C; it also agglomerated with a xylose mass fraction of 7% in water. - Highlights: • D-xylose reacts to form maleic anhydride and acrylic acid above 250 °C. • Vanadyl pyrophosphate is both active and selective for maleic and acrylic acid. • Acid and acrolein yield approaches 50% for a xylose mass fraction of 3% in water. • Catalyst agglomerates at low temperatures and high xylose aqueous mass fraction. • Atomization quality is a determining factor to minimize agglomeration

  5. Crystallographic and thermodynamic characterization of phenylaminopyridine bisphosphonates binding to human farnesyl pyrophosphate synthase.

    Directory of Open Access Journals (Sweden)

    Jaeok Park

    Full Text Available Human farnesyl pyrophosphate synthase (hFPPS catalyzes the production of the 15-carbon isoprenoid farnesyl pyrophosphate. The enzyme is a key regulator of the mevalonate pathway and a well-established drug target. Notably, it was elucidated as the molecular target of nitrogen-containing bisphosphonates, a class of drugs that have been widely successful against bone resorption disorders. More recently, research has focused on the anticancer effects of these inhibitors. In order to achieve increased non-skeletal tissue exposure, we created phenylaminopyridine bisphosphonates (PNP-BPs that have bulky hydrophobic side chains through a structure-based approach. Some of these compounds have proven to be more potent than the current clinical drugs in a number of antiproliferation assays using multiple myeloma cell lines. In the present work, we characterized the binding of our most potent PNP-BPs to the target enzyme, hFPPS. Co-crystal structures demonstrate that the molecular interactions designed to elicit tighter binding are indeed established. We carried out thermodynamic studies as well; the newly introduced protein-ligand interactions are clearly reflected in the enthalpy of binding measured, which is more favorable for the new PNP-BPs than for the lead compound. These studies also indicate that the affinity of the PNP-BPs to hFPPS is comparable to that of the current drug risedronate. Risedronate forms additional polar interactions via its hydroxyl functional group and thus exhibits more favorable binding enthalpy; however, the entropy of binding is more favorable for the PNP-BPs, owing to the greater desolvation effects resulting from their large hydrophobic side chains. These results therefore confirm the overall validity of our drug design strategy. With a distinctly different molecular scaffold, the PNP-BPs described in this report represent an interesting new group of future drug candidates. Further investigation should follow to

  6. Chromosomal abnormalities and autism

    Directory of Open Access Journals (Sweden)

    Farida El-Baz

    2016-01-01

    Conclusion: Chromosomal abnormalities were not detected in the studied autistic children, and so the relation between the genetics and autism still needs further work up with different study methods and techniques.

  7. Chromosomal Abnormalities in ADHD

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-07-01

    Full Text Available The prevalence of fragile X syndrome, velocardiofacial syndrome (VCFS, and other cytogenetic abnormalities among 100 children (64 boys with combined type ADHD and normal intelligence was assessed at the NIMH and Georgetown University Medical Center.

  8. "Jeopardy" in Abnormal Psychology.

    Science.gov (United States)

    Keutzer, Carolin S.

    1993-01-01

    Describes the use of the board game, Jeopardy, in a college level abnormal psychology course. Finds increased student interaction and improved application of information. Reports generally favorable student evaluation of the technique. (CFR)

  9. Abnormal Uterine Bleeding

    Science.gov (United States)

    ... especially the progestin-only pill (also called the “mini-pill”) can actually cause abnormal bleeding for some ... Basics Sports Safety Injury Rehabilitation Emotional Well-Being Mental Health Sex and Birth Control Sex and Sexuality ...

  10. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  11. The aqueous corrosion behavior of technetium - Alloy and composite materials

    International Nuclear Information System (INIS)

    Jarvinen, G.; Kolman, D.; Taylor, C.; Goff, G.; Cisneros, M.; Mausolf, E.; Poineau, F.; Koury, D.; Czerwinski, K.

    2013-01-01

    Metal waste forms are under study as possible disposal forms for technetium and other fission products. The alloying of Tc is desirable to reduce the melting point of the Tc-containing metal waste form and potentially improve its corrosion resistance. Technetium-nickel composites were made by mixing the two metal powders and pressing the mixture to make a pellet. The as-pressed composite materials were compared to sintered composites and alloys of identical composition in electrochemical corrosion tests. As-pressed samples were not robust enough for fine polishing and only a limited number of corrosion tests were performed. Alloys and composites with 10 wt% Tc appear to be more corrosion resistant at open circuit than the individual components based on linear polarization resistance and polarization data. The addition of 10 wt% Tc to Ni appears beneficial at open circuit, but detrimental upon anodic polarization. Qualitatively, the polarizations of 10 wt% Tc alloys and composites appear like crude addition of Tc plus Ni. The 1 wt% Tc alloys behave like pure Ni, but some effect of Tc is seen upon polarization. Cathodic polarization of Tc by Ni appears feasible based on open circuit potential measurements, however, zero resistance ammetry and solution measurements are necessary to confirm cathodic protection

  12. Analysis of americium, plutonium and technetium solubility in groundwater

    International Nuclear Information System (INIS)

    Takeda, Seiji

    1999-08-01

    Safety assessments for geologic disposal of radioactive waste generally use solubilities of radioactive elements as the parameter restricting the dissolution of the elements from a waste matrix. This study evaluated americium, plutonium and technetium solubilities under a variety of geochemical conditions using the geochemical model EQ3/6. Thermodynamic data of elements used in the analysis were provided in the JAERI-data base. Chemical properties of both natural groundwater and interstitial water in buffer materials (bentonite and concrete) were investigated to determine the variations in Eh, pH and ligand concentrations (CO 3 2- , F - , PO 4 3- , SO 4 2- , NO 3 - and NH 4 + ). These properties can play an important role in the complexation of radioactive elements. Effect of the groundwater chemical properties on the solubility and formation of chemical species for americium, plutonium and technetium was predicted based on the solubility analyses under a variety of geochemical conditions. The solubility and speciation of the radioactive elements were estimated, taking into account the possible range of chemical compositions determined from the groundwater investigation. (author)

  13. The retention mechanism of technetium-99m-HM-PAO

    DEFF Research Database (Denmark)

    Neirinckx, R D; Burke, J F; Harrison, R C

    1988-01-01

    Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation of the b......Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation....... This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99mTc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data...

  14. Labelling of metaiodobenzylguanidine (MIBG) with Technetium-99m radionuclide

    International Nuclear Information System (INIS)

    Maula Eka Sriyani; Dini Natanegara; Aang Hanafiah Ws

    2015-01-01

    Various neuroendocrine tumors and their metastases are able to localized and staged by Metaiodobenzylguanidine (MIBG). MIBG is a molecule that has a chemical structure similarities with noradrenaline in the adrenal. The research on 131 I-MIBG has been successfully conducted in the tumor imaging. This research of preparing 99m Tc-MIBG that will be used as a diagnostic agent for adrenal tumors was carried out. MIBG labeling activities with technetium-99m radionuclide were carried out through labeling of MIBG with technetium-99m and radiochemical purity analysis. The labeling of MIBG was carried out using both direct and indirect methods with diethylene triamine pentaacetic acid (DTPA) as a co-ligand. Determination of 99m Tc-MIBG labeling efficiency was performed using paper chromatography with Whatman 3MM/dried acetone and Whatman 31ET/acetonitrile 50%. The results of labeling efficiency using the indirect method with DTPA as a co-ligand was obtained 93.44 ± 1.93%, which the concentration of MIBG was 2 mg/0.5 mL H 2 O, concentration of co-ligand was 37,5 μg of SnCl 2 .2H 2 O and DTPA of 1,125 mg at pH 6.5 for 15 minutes incubation in the room temperature ( 25 °C). (author)

  15. Monoclonal anti-elastin antibody labelled with technetium-99m

    International Nuclear Information System (INIS)

    Oliveira, Marcia B.N. de; Silva, Claudia R. da; Araujo, Adriano C. de; Bernardo Filho, Mario; Porto, Luis Cristovao M.S.; Gutfilen, Bianca; Souza, J.E.Q.; Frier, Malcolm

    1999-01-01

    Technetium-99m ( 99m Tc) is widely employed in nuclear medicine due to its desirable physical, chemical and biological properties. Moreover, it is easily available and normally is inexpensive. A reducing agent is necessary to label cells and molecules with 99m Tc and stannous chloride (Sn C L 2 ) is usually employed. Elastin is the functional protein component of the elastic fiber and it is related with some diseases such as arteriosclerosis, pulmonary emphysema and others. The present study refers to the preparation of the 99m Tc labeled monoclonal anti-elastin antibody. The monoclonal antibody was incubated with an excess of 2-iminothiolane. The free thiol groups created, were capable of binding with the reduced technetium. Labeling was an exchange reaction with 99m Tc-glucoheptonate. The labeled preparation was left at 4 deg C for one hour. Then, it was passed through a Sephadex G50 column. Various fractions were collected and counted. A peak corresponding to the radiolabeled antibody was obtained. Stability studies of the labelled anti-elastin were performed at 0,3 6, 24 hours, at both 4 deg C or room temperature. The biodistribution pattern of the 99m Tc-anti-elastin was studied in healthy male Swiss mice. The immunoreactivity was also determined. An useful labeled-anti-elastin was obtained to future immunoscintigraphic investigations. (author)

  16. Biomedical tracers: technetium-99 m complexing sulfur polydentate ligands

    International Nuclear Information System (INIS)

    Bendennoune, A.

    1994-01-01

    Cyclic and acyclic tetra sulfur ligands have been synthesized and some of them have been labelled with technetium-99m. These works have two different aims: 1- Development of methods permitting to obtain easily potential technetium complexing sulfur polydentate chelates. 2- Research of positive and neutral complexes of this metal likely to replace thalium-201 in the coronary flow estimation and [TcO-HMPAO] sup 0 complex in the cerebral scintigraphy, respectively. In this work, first, different ways for obtaining dithioetherdithiols and cyclic tetrathioethers containing functional groups have been carried out, then complexation of the core of nitrutechnetium (TcN) sup 2+ at tracers scale, by dithioetherdithiols, using exchange reaction with [sup 9 sup 9 sup m TcNCl sub 4 ] sup - ion complex or sup 99 sup m TcN Cl sub 2 [P(CH sub 2 CH sub 2 CN) sub 3 ] sub 2 has been studied. Finally, biological distribution in swiss mouse of these technetiated complexes has been studied. 135 refs., 30 figs., 13 tabs. (F.M.)

  17. Stripping voltammetric behavior of technetium at various chemically modified electrodes

    International Nuclear Information System (INIS)

    Dick, R.

    1990-09-01

    In monitoring of nuclear processing plants and storage facilities the necessity arises of assaying traces of the artificial radioactive element technetium. The oxidation states IV and VII are of particular interest. Stripping voltammetry is among the methods of assay which are suited for this purpose. It allows an enhanced selectivity to be achieved by preconcentration of the analyte and of an oxidation state of the analyte, respectively, at the electrode used. This specific enrichment is successful after appropriate chemical modification of the electrode through immobilization of a Tc-specific reagent. When various approaches of chemical modification of a glassy carbon electrode were examined, the tetraphenylarsonium chloride extractant, which is highly selective with respect to technetium, proved to be the best suited reagent, capable of fixation both by ionic and by covalent bonding on an electrodeposited polymer film. For ionic immobilization the reagent was reacted to m-sulfophenyltriphenyl arsonium and then bound to a copolymer of vinylferrocene and vinylpyridine, which had been provided with cations. It was possible to enrich Tc(VII) at such an electrode and to determine it by stripping voltammetry down to a concentration of 1x10 -8 M after 5 minutes enrichment time. (orig./EF) [de

  18. Nature`s uncommon elements: Plutonium and technetium

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, D.; Fabryka-Martin, J.; Dixon, P. [Los Alamos National Lab., NM (United States). Chemical Science and Technology Div.; Cramer, J. [Atomic Energy of Canada Ltd., Pinawa, Manitoba (Canada). Whiteshell Lab.

    1998-01-06

    The authors have taken advantage of the extremely sensitive method of thermal ionization mass spectrometry to measure technetium and plutonium concentrations in sample masses that are smaller by as much as three orders of magnitude than those used in the early research efforts. The work reported in this paper extends the understanding of the geochemistry of plutonium and technetium by developing detailed descriptions of their associations in well characterized geologic samples, and by using modern neutron-transport modeling tools to better interpret the meaning of the results. Analyses were conducted on samples from three uranium ore deposits selected for their contrasting geochemical environments. The Cigar Lake deposit is an unweathered, unaltered primary ore in a reducing environment which is expected to closely approximate a system that is closed with respect to uranium and its products. The Koongarra deposit is a shallow system, both altered and weathered, subject to active ground water flow. Finally, a sample from the Beaverlodge deposit is included because it is a commercially-available uranium ore standard that allows demonstration of the precision of the analytical results.

  19. The aqueous corrosion behavior of technetium - Alloy and composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Jarvinen, G.; Kolman, D.; Taylor, C.; Goff, G.; Cisneros, M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Mausolf, E.; Poineau, F.; Koury, D.; Czerwinski, K. [Department of Chemistry, University of Nevada, Las Vegas, Las Vegas, NV 89154 (United States)

    2013-07-01

    Metal waste forms are under study as possible disposal forms for technetium and other fission products. The alloying of Tc is desirable to reduce the melting point of the Tc-containing metal waste form and potentially improve its corrosion resistance. Technetium-nickel composites were made by mixing the two metal powders and pressing the mixture to make a pellet. The as-pressed composite materials were compared to sintered composites and alloys of identical composition in electrochemical corrosion tests. As-pressed samples were not robust enough for fine polishing and only a limited number of corrosion tests were performed. Alloys and composites with 10 wt% Tc appear to be more corrosion resistant at open circuit than the individual components based on linear polarization resistance and polarization data. The addition of 10 wt% Tc to Ni appears beneficial at open circuit, but detrimental upon anodic polarization. Qualitatively, the polarizations of 10 wt% Tc alloys and composites appear like crude addition of Tc plus Ni. The 1 wt% Tc alloys behave like pure Ni, but some effect of Tc is seen upon polarization. Cathodic polarization of Tc by Ni appears feasible based on open circuit potential measurements, however, zero resistance ammetry and solution measurements are necessary to confirm cathodic protection.

  20. Determination of degradation conditions of exchange resins containing technetium

    International Nuclear Information System (INIS)

    Rivera S, A.; Monroy G, F.; Quintero P, E.

    2014-10-01

    The quantification of Tc-99 in spent exchange resins, coming from nuclear power plants, is indispensable to define their administration. The Tc-99 is a pure beta emitter of 210000 years of half-life, volatile and of a high mobility in water and soil. For this reason, the objective of this work is to establish a digestion method of ionic exchange resins containing technetium that retains more than 95% of this radioisotope. Mineralization tests were carried out of a resin Amberlite IRN-150 by means of an oxidation heat, in acid medium, varying the resin mass, the medium volume, the media type, the temperature and the digestion time. The digested samples were analyzed by gas chromatography to estimate the grade of their degradation. The 99m Tc was used as tracer to determine the technetium percentage recovered after mineralizing the resin. The digestion process depends on the temperature and the resin mass. At higher temperature better mineralization of samples and to greater resin mass to a constant temperature, less degradation of the resin. The spectra beta of the 99m Tc and 99 Tc are presented. (Author)

  1. Labelling of biological structures with technetium 99 m

    International Nuclear Information System (INIS)

    Bernardo Filho, M.

    1988-01-01

    The labelling of red blood cells (RBC) with technetium 99m ( 99m Tc) depends on several factors, as the stannous ion (Sn ++ ) concentration, the time and temperature of incubation, the anticoagulant utilized, the presence of plasma proteins (PP) and others. Although the blinding of 99m Tc with hemoglobin and PP are similar, they appear to have specific characteristics as demonstrated by precipitation with alcohol, acetone, trichloroacetic acid, hydrochloric acid and mercury chloride. The bacterial cultures labeled with Technetium- 99m , at optimal Sn ++ ion concentration, presents a large stability and their viability is not altered by this treatment. The electrophoretic mobility, the hydrophobicity, the cationized ferritin distribution and the adherence to human buccal epithelial cells are not modified either. The possibility of labelling with 99m Tc of planaria and cercariae of Schistossoma mansoni evaluative cycle increases the utilization of this radionuclide to an experimental level. The results described with the labelling of these biological structures with 99m Tc demonstrated that stable labeled and viable operations are obtained. (author)

  2. Biosynthesis of (+)-cis- and (+)-trans-sabinene hydrate from geranyl pyrophosphate by a soluble enzyme system from sweet marjoram (Majorana hortensis)

    International Nuclear Information System (INIS)

    Hallahan, T.W.

    1988-01-01

    A soluble enzyme preparation from the leaves of sweet marjoram (Majorana hortensis Moench) catalyzes the divalent cation-dependent cyclization of [1- 3 H]geranyl pyrophosphate to the bicyclic monoterpene alcohols (+)-cis- and (+)-trans-[6 3 H]sabinene hydrate, providing labeling patterns consistent with current mechanistic considerations. The two enzymatic activities were inseparable by several chromatographic procedures, and differential inactivation studies suggesting that the two activities reside with the same enzyme. The enzymatic cyclization is considered to proceed by the initial ionization and isomerization of geranyl pyrophosphate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this enzyme bound tertiary allylic intermediate to the monocyclic (+)-(4R)-α-terpinyl cation. A 1,2-hydride shift and a second cyclization with water capture of the resulting cation completes the reaction sequence. No free intermediates were detectable in the conversion of geranyl pyrophosphate to the sabinene hydrates as determined by isotopic dilution experiments

  3. Scintigraphy with /sup 111/In-labeled antimyosin F(ab)/sub 2/ monoclonal antibody and /sup 99m/Tc-pyrophosphate in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T.; Schuemichen, C.; Hohenloser, S.; Kasper, W.; Meinertz, T.

    1988-02-01

    A report is presented of the scintigraphic diagnosis of a generalized rhabdomyolysis with myocardial involvement using /sup 111/In labelled antimyosin F(ab)/sub 2/ monoclonal antibodies as compared to /sup 99m/Tc pyrophosphate.

  4. Influence of synthesis conditions on physicochemical parameters and corrosion inhibiting activity of strontium pyrophosphates SrMIIP2O7 (MII = Mg and Zn).

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Dohnalová, Ž.; Šulcová, P.; Bělina, P.; Vlček, Milan

    2016-01-01

    Roč. 93, 1 April 2016 (2016), s. 77-86 ISSN 0300-9440 Institutional support: RVO:61389013 Keywords : anticorrosive properties * paint coating * pyrophosphate Subject RIV: CA - Inorganic Chemistry Impact factor: 2.858, year: 2016

  5. Abnormal sound detection device

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji.

    1995-01-01

    Only components synchronized with rotation of pumps are sampled from detected acoustic sounds, to judge the presence or absence of abnormality based on the magnitude of the synchronized components. A synchronized component sampling means can remove resonance sounds and other acoustic sounds generated at a synchronously with the rotation based on the knowledge that generated acoustic components in a normal state are a sort of resonance sounds and are not precisely synchronized with the number of rotation. On the other hand, abnormal sounds of a rotating body are often caused by compulsory force accompanying the rotation as a generation source, and the abnormal sounds can be detected by extracting only the rotation-synchronized components. Since components of normal acoustic sounds generated at present are discriminated from the detected sounds, reduction of the abnormal sounds due to a signal processing can be avoided and, as a result, abnormal sound detection sensitivity can be improved. Further, since it is adapted to discriminate the occurrence of the abnormal sound from the actually detected sounds, the other frequency components which are forecast but not generated actually are not removed, so that it is further effective for the improvement of detection sensitivity. (N.H.)

  6. Technetium-99 in lobsters from the western Irish sea

    International Nuclear Information System (INIS)

    Fegan, Mary

    1999-05-01

    Technetium-99, the most important radionuclide of technetium release to the environment, is a pure beta emitter with a half-life of 2.13 x 10(5) years. It behaves conservatively in seawater and is likely to remain available to biota for a long time. The dominant and most stable form of technetium in oxygenated seawater is the pertechnetate ion, Tco4. The principle source of radionuclide contamination of the Irish Sea has been the liquid waste discharges of low level radionuclide effluent from the spent nuclear fuel reprocessing plant at Sellafield on the Cumbria Coast. In 1994 the annual discharge authorization limit for 99Tc was increased from 10 TBq to 200 TBq. Lobster concentrates 99Tc to a high degree with concentration factors of 1x 10(3) reported in the literature. The mean 99Tc activity concentrations in lobsters caught close to Sellafield were reported to have risen by a factor of 20 in 2 years from 390 Bq/kg (wet weight) in 1993 to 8300 Bq/kg (wet weight) in 1995. This study was undertaken to determine the 99Tc activity concentration in lobsters from the western Irish Sea. Lobsters were collected from the east and north east coasts of Ireland over the period June 1997 to July 1998 and analysed using a radioanalytical method which was based on the anion-exchange seperation of technetium as pertechnetate. A gas-flow proportional counter was used to measure to 99Tc activity concentration in each sample. Technetium-99 activity concentrations were measured in the muscle from the tail, the right and the left claws and also in the green gland, the hepatopancreas and the cardiac fore-gut. The results of the measurements showed, as expected, that the 99Tc activity concentrations were not as high as those in the samples from the Cumbrian coast. The mean 99Tc activity concentrations, over the sampling period, in the tail, right and left claw muscles were 214, 124 and 136 BQ/kg (wet weight) respectively. The mean 99Tc activity concentrations in the green gland

  7. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  8. The radiochemical purity of technetium-99m-tin-diethylene-triamino-pentaacetic acid (DTPA) complex

    International Nuclear Information System (INIS)

    Besnard, M.; Costerousse, O.; Merlin, L.; Coehn, Y.

    1975-01-01

    The effect on radiochemical purity was studied as a function of the storage period of tin-DTPA solution and of the technetium-complex solution. The quantity of the pertechnetate ions present in the solution is determined by ascending paper chromatography, and an attempt was made to clarify the bond type of technetium by a spectrophotometric method. The tin-DTPA solutions for complexing of the reduced technetium are stable over a period of 8 weeks. The yield of the radiopharmaceutical product is better than 95%. (G.Gy.)

  9. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  10. Studies in technetium chemistry, Project 1: Evaluation of technetium acetylacetonates as potential cerebral blood flow agents, Project 2

    International Nuclear Information System (INIS)

    Jones, A.G.; Packard, A.B.; Treves, S.; Davison, A.

    1990-01-01

    Although the emphasis in our original submission was on N 2 S 2 and N 3 S coordinating ligands in technetium(V), we have now broadened the chemistry studies into areas that encompass new systems that allow the generation of neutral complexes. This change was based upon developments that have taken place in our basic chemistry studies that could bear on one of the original aims of this work, i.e., the design of complexes designed to penetrate cellular membranes and to remain trapped in target tissues. Among these topics are oxotechnetium(V) complexes containing amine and alcoholate ligands, coordination compounds containing the alternative technetium(V) nitrido core and the synthesis at macroscopic levels of a tetradentate ''umbrella'' ligand that successfully binds the metal. Basic studies with the original bisamide-bisthiol ligand system have continued with the identification of the products formed when aqueous solutions of the complex [TcO(ema)] - are acidified. This material is isolatable as yellow/brown crystals when HCl is added to the tetraphenylarsonium salt of the complex synthesized according to published procedures. Elemental analysis, FAB(+) mass spectrometry and 1 H NMR results were consistent with the formulation TcO(ema)H. Infrared spectra showed a dramatic shift in the Tc = O stretch to 966 cm -1 , as distinct from 945 cm -1 in the original complex

  11. Hemodynamic changes as a result of experimental heart failure in sheep as observed with technetium 99m

    International Nuclear Information System (INIS)

    Van Rooyen, J.M.

    1978-01-01

    The aim of this project is to study heart failure in sheep that have gousiekte by using technetium 99m to determine the blood flow. Gousiekte is a congestive cardiomyopathy that occurs in ruminant animals. It is characterised by a latent period of 2-6 weeks followed by a sudden death. It appears that during gousiekte the stroke volume decreases with about 40% and the PFI increases with more than a 100%. The decrease in stroke volume is observed by means of an electromagnetic bloodflow meter. The greater change in PFI than stroke volume during gousiekte is a sign that there is congestive failure of the left ventricle. A decrease in ejection fraction has been observed by a loss of value lower than 30% after the final congestive phase has been reached. Normally 7,4 plus minus 0,3 contractions of a sheep's heart are needed to pump the blood from the right to left side of the heart. Complete congestive failure during gousiekte can decrease the effectiveness of the heart so that 50 contractions are needed, in other words a PFI value of 50. Two phases can be distinguished during the development of gousiekte namely a compensation phase and a decompensation phase. The PFI as criterion is used to establish the influence of certain drugs with an inotropic effect and to establish whether a gousiekte heart can protentiate after administration of the drugs. The findings are positive which shows than energy abnormalities are not primary causes of gousiekte. As a model for heart failure gousiekte can be compared with other well known models of heart failure such a volume overload, pressure overload and coronary ligatures in sheep. The by-product of this research is the development and possible application of the technetium isotope method to diagnose heart failure in sheep

  12. Scintigraphic myocardial imaging with sup(99m)Tc-labelled pyrophosphate of experimentally produced cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Mazurova, Y.; Bradna, P.

    1981-12-01

    Scintigraphic examination of the myocardium using sup(99m)Tc-labelled pyrophosphate was carried out in 10 dogs with experimentally produced cardiomyopathy. This was brought by introvenous administration of high doses of adrenalin and theophylline. The scan was positive in 8 out of 10 dogs. Hot foci were very extensive. The degree of accumulation was however low (2+). Histological examination of the myocardium using the light microscope showed only scarcely distinguishable damage to the tissue without the presence of necrosis. ECG examinations were normal in all cases. By means of sup(99m)Tc-labelled pyrophosphate even very small myocardial disorders can thus be detected. This fact may be of clinical importance for an early diagnosis of heart lesions.

  13. Three-dimensional structure of phosphoribosyl pyrophosphate synthetase from E. coli at 2.71 Å resolution

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, V. I., E-mail: inna@ns.crys.ras.ru, E-mail: tostars@mail.ru, E-mail: ugama@yandex.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Abramchik, Yu. A. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Zhukhlistova, N. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Muravieva, T. I.; Esipov, R. S. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Kuranova, I. P. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-01-15

    Phosphoribosyl pyrophosphate synthetase from Escherichia coli was cloned, purified, and crystallized. Single crystals of the enzyme were grown under microgravity. The X-ray diffraction data set was collected at the Spring-8 synchrotron facility and used to determine the three-dimensional structure of the enzyme by the molecular-replacement method at 2.71 Å resolution. The active and regulatory sites in the molecule of E. coli phosphoribosyl pyrophosphate synthetase were revealed by comparison with the homologous protein from Bacillus subtilis, the structure of which was determined in a complex with functional ligands. The conformations of polypeptide-chain fragments surrounding and composing the active and regulatory sites were shown to be identical in both proteins.

  14. Determination of the vitality of the femoral head with sup(99m)Tc-Sn-pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Greiff, J.

    1980-01-01

    A series of 14 patients who for various reasons were scheduled for total hip replacement were investigated. sup(99m)Tc-Sn-pyrophosphate scintigraphy and tetracycline labelling of the bone structure was performed prior to surgery, and subsequently the femoral heads were submitted to histological evaluation on decalcified as well as non-decalcified slides. The evaluation of the scintigraphs was performed by a specialist in nuclear medicine and the histological slides were evaluated by a pathologist, in the both cases without the radiological findings or the clinical history. The scintigraphic evaluations of the vitality of the femoral head were in all cases verified by the histological examination, whereas the radiological findings in three cases failed to demonstrate that a femoral head necrosis actually was present. From this study it can be concluded that sup(99m)Tc-Sn-pyrophosphate scintigraphy is an excellent method of assessing bone vitality in the femoral head. (author)

  15. Thermal lens study of thermo-optical properties and concentration quenching of Er3+-doped lead pyrophosphate based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C. C. [Universidade Federal do Ceara, Ceara, Brazil; Rocha, U. [Grupo de Fotônica e Fluidos Complexos, Instituto de Física, Brazil; Guedes, Ilde [Universidade Federal do Ceara, Ceara, Brazil; Vermelho, M. V. D. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil; Boatner, Lynn A [ORNL; Jacinto, C. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil

    2012-01-01

    In this work, we have used the thermal lens technique combined with conventional spectroscopy to characterize the thermo-optical properties of Er3+-doped lead pyrophosphate-based glasses. More precisely, we have investigated and quantified experimentally the fluorescence quantum efficiencies of the Er3+ levels, and we describe the role of concentration quenching effects. The fluorescence quantum efficiency of the 4I13/2 level is very high when compared to other phosphate glasses, while that of the green-coupled levels is very small. Other important photonic materials parameters, such as the thermal diffusivity and temperature coefficient of the optical path length change, were obtained and compared with those of other glass systems. The cumulative results obtained here for the Er-doped lead pyrophosphate glass show that this material is a good candidate for photonic applications with a characteristic Er3+ infrared emission around 1550 nm.

  16. Improved performance of Nb-doped vanadyl pyrophosphate, catalyst for n-butane oxidation to maleic anhydride

    Energy Technology Data Exchange (ETDEWEB)

    Pavarelli, G.; Caldarelli, A.; Cavani, F. [Bologna Univ. (Italy). Dipt. di Chimica Industriale ' Toso Montanari' ; Cortelli, C.; Luciani, S. [Polynt SpA, Scanzorosciate (Italy)

    2013-11-01

    We report here about an investigation on the role of Nb{sup 5+} when used as a promoter for vanadyl pyrophosphate, catalyst for the oxidation of n-butane to maleic anhydride. The effect of Nb was very complex, a function of both its amount and the reaction temperature used. The optimal catalytic behavior was shown for very low Nb contents, i.e., for a V/Nb atomic ratio as low as 150. The main role of Nb was that of accelerating the formation of a limited amount of {gamma}-VOPO{sub 4} on the surface of vanadyl pyrophosphate, by accelerating the oxidation of V{sup 4+} into V{sup 5+} under reaction conditions. (orig.)

  17. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    International Nuclear Information System (INIS)

    Batista, J.F.; Galiano, M.C.; Torres, L.A.; Hernandez, M.C.; Sosa, F.; Perera, A.; Perez, M.

    1995-01-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of 99m Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of 99m Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  18. Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease

    International Nuclear Information System (INIS)

    Sullo, P.; Cuocolo, A.; Nicolai, E.; Cardei, S.; Nappi, A.; Squame, F.; Covelli, E.M.; Pace, L.; Salvatore, M.

    1996-01-01

    The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99m Tc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (≥50% luminal stenosis) (n=50) had an abnormal 99m Tc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall senstivity, specificity and diagnostic accuracy in the detection of individual stenosed vissels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P 75%). (orig.)

  19. A new application of stannic pyrophosphate in nuclear medicine: scintigraphy of choroid plexus, morphological and quantitative study

    International Nuclear Information System (INIS)

    Tovar, G. de; Akerman, M.; Panneciere, C.; Perez, R.

    1975-01-01

    It was shown that the concentration of pertechnetate (Tc 99m) in the choroid plexus can be increased by previous injection of stannic pyrophosphate. This phenomenon affords an excellent morphological study of these structures, which trace most of the cerebral ventricles. An isotopic ventricle scintigraph is thus obtained by simple intraveinous injection. Furthermore a dynamic study supplies information on the functional activity of choroid plexus, of special interest in research on the pathology of the cerebrospinal fluid [fr

  20. Post-traumatic avascular necrosis of the femoral head predicted by preoperative technetium-99m antimony-colloid scan: an experimental and clinical study

    International Nuclear Information System (INIS)

    Turner, J.H.

    1983-01-01

    Technetium-99m antimony colloid was used to visualize the bone marrow of the head of the femur within twenty-four hours after interruption of the blood supply by subcapital osteotomy and section of the ligamentum teres in thirteen rabbits and within twenty-four hours after a subcapital fracture in thirty patients. Of the rabbits, all showed loss of marrow radioactivity over the affected femoral head. Bone-imaging with technetium-99m methylene diphosphonate, in contrast, failed to demonstrate any abnormality in the avascular head of the femur for as long as forty-eight hours after osteotomy. This difference between the marrow scan and the bone scan was attributed to earlier loss of function in the marrow cells than in the osteocytes. The thirty patients who had a preoperative scan within twenty-four hours after sustaining a subcapital fracture were treated by internal fixation with a Richards screw and plate and were followed for as long as two years, or until the patient died or radiographs showed evidence of avascular necrosis. The preoperative technetium-99m antimony-colloid activity in the head of the fractured femur was normal in sixteen patients and absent in fourteen; two of the fourteen had no activity in either hip, which precluded assessment of the fractured hip in these patients. In fifteen of the sixteen hips, preservation of the uptake in the marrow of the head of the fractured femur preoperatively predicted normal healing. Late segmental collapse developed in the remaining hip. In eleven of the twelve patients who had loss of marrow activity in the femoral head preoperatively, avascular necrosis developed within two years

  1. The characteristics of pyrophosphate: D-fructose-6-phosphate 1-phosphotransferases from Sansevieria trifasciata leaves and Phaseolus coccineus stems.

    Science.gov (United States)

    Kowalczyk, S

    1987-01-01

    Three different molecular forms of pyrophosphate-dependent phosphofructokinase have been isolated: one from Sansevieria trifasciata leaves and two from Phaseolus coccineus stems. The form isolated from S. trifasciata has the molecular weight of about 115,000. The apparent molecular weights for the two forms from mung bean were approximately 220,000 and 450,000. All three forms have the same pH optima, an absolute requirement for Mg2+ ions both in the forward and reverse reaction, but differ in their sensitivity toward fructose 2,6-bisphosphate. Kinetic properties of the partially purified enzymes have been investigated in the presence and absence of fructose 2,6-bisphosphate. Pyrophosphate-dependent phosphofructokinase from S. trifasciata exhibited hyperbolic kinetics with all substrates tested. The saturation curves of the enzyme (form A) from mung bean for pyrophosphate, fructose 6-phosphate and fructose 1,6-bisphosphate were sigmoidal in the absence of fructose 2,6-bisphosphate. In the presence of fructose 2,6-bisphosphate these kinetics became hyperbolic.

  2. Cofortification of ferric pyrophosphate and citric acid/trisodium citrate into extruded rice grains doubles iron bioavailability through in situ generation of soluble ferric pyrophosphate citrate complexes.

    Science.gov (United States)

    Hackl, Laura; Cercamondi, Colin I; Zeder, Christophe; Wild, Daniela; Adelmann, Horst; Zimmermann, Michael B; Moretti, Diego

    2016-05-01

    Iron fortification of rice is a promising strategy for improving iron nutrition. However, it is technically challenging because rice is consumed as intact grains, and ferric pyrophosphate (FePP), which is usually used for rice fortification, has low bioavailability. We investigated whether the addition of a citric acid/trisodium citrate (CA/TSC) mixture before extrusion increases iron absorption in humans from FePP-fortified extruded rice grains. We conducted an iron absorption study in iron-sufficient young women (n = 20), in which each participant consumed 4 different meals (4 mg Fe/meal): 1) extruded FePP-fortified rice (No CA/TSC); 2) extruded FePP-fortified rice with CA/TSC added before extrusion (CA/TSC extruded); 3) extruded FePP-fortified rice with CA/TSC solution added after cooking and before consumption (CA/TSC solution); and 4) nonextruded rice fortified with a FeSO4 solution added after cooking and before consumption (reference). Iron absorption was calculated from erythrocyte incorporation of stable iron isotopes 14 d after administration. In in vitro experiments, we assessed the soluble and dialyzable iron from rice meals in which CA/TSC was added at different preparation stages and from meals with different iron:CA:TSC ratios. Fractional iron absorption was significantly higher from CA/TSC-extruded meals (3.2%) than from No CA/TSC (1.7%) and CA/TSC solution (1.7%; all P solubility and dialyzability were higher in CA/TSC-extruded rice than in rice with No CA/TSC and CA/TSC solution, and solubility increased with higher amounts of added CA and TSC in extruded rice. Iron bioavailability nearly doubled when CA/TSC was extruded with FePP into fortified rice, resulting in iron bioavailability comparable to that of FeSO4 We attribute this effect to an in situ generation of soluble FePP citrate moieties during extrusion and/or cooking because of the close physical proximity of FePP and CA/TSC in the extruded rice matrix. This trial was registered at

  3. Immobilization and Limited Reoxidation of Technetium-99 by Fe(II)-Goethite

    Energy Technology Data Exchange (ETDEWEB)

    Um, Wooyong; Chang, Hyun-shik; Icenhower, Jonathan P.; Qafoku, Nikolla; Smith, Steven C.; Serne, R. Jeffrey; Buck, Edgar C.; Kukkadapu, Ravi K.; Bowden, Mark E.; Westsik, Joseph H.; Lukens, Wayne W.

    2010-09-30

    This report summarizes the methodology used to test the sequestration of technetium-99 present in both deionized water and simulated Hanford Tank Waste Treatment and Immobilization Plant waste solutions.

  4. Analysis of one thousand liver scans carried out using technetium phytate

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, J; de Laforte, C; Roux, F; Bisset, J P; Paulin, R [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France)

    1977-10-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen, and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver.

  5. Analysis of one thousand liver scans carried out using technetium phytate

    International Nuclear Information System (INIS)

    Pasquier, J.; Laforte, C. de; Roux, F.; Bisset, J.P.; Paulin, R.

    1977-01-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver [fr

  6. Chemistry of rhenium and technetium. II. Schiff base complexes with polyfunctional amino acids

    International Nuclear Information System (INIS)

    Du Preez, J.G.H.; Gerber, T.I.A.; Fourie, P.J.; Van Wyk, A.J.

    1984-01-01

    Amino acid Schiff base technetium(V) complexes of salicylaldehyde with l-cysteine, l-serine, l-histodine, l-threonine, l-glutamic acid and l-tryptophan have been preapred by direct reaction and by constituent combination. The amino acid part of the ligands coordinates to the technetium through the carboxylate group, while the other available functional group of the amino acids plays a more minor role as blocking group or in intramolecular bonding. 3 tables

  7. A method for the preparation of lipophilic macrocyclic technetium-99m complexes

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.

    1991-01-01

    A procedure for the preparation of technetium complexes applicable as diagnostic radiopharmaceuticals is suggested and documented with 27 examples. Technetium-99m is reacted with a suitable complexant selected from the class of alkylenamine oximes containing 2 or 3 carbon atoms in the alkylene group. The lipophilic macrocyclic complexes possess an amine, amide, carboxy, carboxy ester, hydroxy or alkoxy group or a suitable electron acceptor group. (M.D.). 7 tabs

  8. Obtention of scintillography images by low density lipoproteins labelled with technetium 99

    International Nuclear Information System (INIS)

    Silva, S.; Coelho, I.; Zanardo, E.; Pileggi, F.; Meneguethi, C.; Maranhao, R.C.

    1992-01-01

    The low density lipoproteins carry the most part of the cholesterol in the blood plasma. These lipoproteins are labelled with technetium-99-m and have been used for obtaining images in nuclear medicine. The introduction of this technique is presented, aiming futures clinical uses. Scintillographic images are obtained 25 minutes and 24 hours after the injection of 3 m Ci of low density lipoproteins - technetium-99 m in rabbits. (C.G.C.)

  9. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  10. Solidification/stabilization of technetium in cement-based grouts

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Bostick, W.D.; Spence, R.D.; Shoemaker, J.L.

    1990-01-01

    Mixed low-level radioactive and chemically hazardous process treatment wastes from the Portsmouth Gaseous Diffusion Plant are stabilized by solidification in cement-based grouts. Conventional portland cement and fly ash grouts have been shown to be effective for retention of hydrolyzable metals (e.g., lead, cadmium, uranium and nickel) but are marginally acceptable for retention of radioactive Tc-99, which is present in the waste as the highly mobile pertechnate anion. Addition of ground blast furnace slag to the grout is shown to reduce the leachability of technetium by several orders of magnitude. The selective effect of slag is believed to be due to its ability to reduce Tc(VII) to the less soluble Tc(IV) species. 12 refs., 4 tabs

  11. Mechanisms of sorption of neptunium and technetium on argillaceous materials

    International Nuclear Information System (INIS)

    Hooker, P.J.; West, J.M.; Noy, D.J.

    1986-01-01

    It is of pressing concern to understand the behaviour of radionuclides in the environment and in particular long-lived ones (e.g. Np-237 and Te-99) in argillaceous rocks. Clay formations have been chosen as likely candidates for holding low level radioactive waste repositories and in the event of leakage of radionuclides into the geosphere some knowledge of their fate is required in a far-field safety assessment study. The objectives of this present work were to examine the properties of neptunium and technetium in ground-waters associated with clay-rich materials and to ascertain the variations in sorption of these radionuclides under different environmental conditions and to use the information in a forecast of transport through a clay layer

  12. The determination of technetium-99 in environmental materials

    International Nuclear Information System (INIS)

    Harvey, B.R.; Ibbett, R.D.; Williams, K.J.; Lovett, M.B.

    1991-01-01

    The Aquatic Environment Protection Division of the Directorate of Fisheries Research (DFR), Lowestoft carries out analyses, on a routine basis, for a considerable range of radionuclides in a wide variety of environmental materials. Technetium-99 is included in the list of radionuclides for which analysis is regularly carried out as part of the DFR monitoring programme. Its determination is inevitably somewhat labour-intensive and over the years the procedures used have changed to accommodate increasing demands for information on the environmental behaviour of the nuclide. Reliable analytical procedures for the radiochemical separation and assaying of 99 Tc are thus important. Radiometric and gravimetric analyses described in this publication have been developed over a substantial period of time and have given excellent results in international intercomparison exercises. (author)

  13. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    International Nuclear Information System (INIS)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-01-01

    Technetium-99m albumin-sucralfate ([/sup 99m/Tc]Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of [/sup 99m/Tc]Su for detecting various grades of esophagitis. [/sup 99m/Tc]Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, [/sup 99m/Tc]Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa

  14. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    International Nuclear Information System (INIS)

    Buckland-Wright, J.C.; Lynch, J.A.; Macfarlane, D.G.; Homoeopathic Hospital, Tunbridge; Fogelman, I.; Emery, P.

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.)

  15. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    Energy Technology Data Exchange (ETDEWEB)

    Buckland-Wright, J.C.; Lynch, J.A. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy); Macfarlane, D.G. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy Homoeopathic Hospital, Tunbridge (UK). Dept. of Rheumatology); Fogelman, I. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Nuclear Medicine); Emery, P. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Rheumatology)

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.).

  16. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-07-01

    Technetium-99m albumin-sucralfate ((/sup 99m/Tc)Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of (/sup 99m/Tc)Su for detecting various grades of esophagitis. (/sup 99m/Tc)Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, (/sup 99m/Tc)Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa.

  17. Extraction of technetium from simulated Hanford tank wastes

    International Nuclear Information System (INIS)

    Chaiko, D.J.; Vojta, Y.; Takeuchi, M.

    1993-01-01

    Aqueous biphasic separation systems are being developed for the treatment of liquid radioactive wastes. These extraction systems are based on the use of polyethylene glycols (PEGs) for the selective extraction and recovery of long-lived radionuclides, such as 129 I, 75 Se, and 99 Tc, from caustic solutions containing high concentrations of nitrate, nitrite, and carbonate. Because of the high ionic strengths of supernatant liquids in Hanford underground storage tanks, aqueous biphasic systems can be generated by simply adding aqueous PEG solutions directly to the waste solution. In the process, anionic species like I - and TcO 4 - are selectively transferred to the less dense PEG phase. The partition coefficient for a wide range of inorganic cations and anions, such as sodium, potassium, aluminum, nitrate, nitrate, and carbonate, are all less than one. The authors present experimental data on extraction of technetium from several simulated Hanford tank wastes at 25 degree and 50 degree C

  18. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  19. Technetium-99m DMSA preparation: Trivial issues causing severe problems

    International Nuclear Information System (INIS)

    Kumar, V.

    1997-01-01

    Urinary tract infection (UTI) in children involving renal parenchyma, upper collecting system or bladder is one of the major causes for consideration in the diagnosis and management of paediatric nuclear medicine. Acute pyelonephritis is one of the prime causes of morbidity associated with urinary tract infection in children which can lead to progressive renal damage. Technetium-99m dimercaptosuccinic acid (DMSA) is used extensively for the assessment of UTI in paediatrics. The radiopharmaceutical preparation could be influenced by several factors, most of them are trivial, but invariably have severe impact on the quality of the scintiphotographs. This communication is mainly to highlight some of the issues related to 99 mTc-DMSA preparation and the possible precautionary measures that need to be taken to obviate unwarranted problems. (author)

  20. Technetium in late-type stars. I. Observations

    International Nuclear Information System (INIS)

    Little-Marenin, I.R.; Little, S.J.

    1979-01-01

    An analysis of about 90 spectra (11 or 13A/mm) of nonvariable and variable (mostly Mira variables) M, MS, S, CS, and C stars for the presence of the radioactive element technetium (T/sub 1/2/approx. =2 x 10 5 y) suggests that Tc is most often present at certain variability periods. Stars with no Tc I lines in their spectra can be found at most periods (P-bar=234/sup d/), whereas stars with Tc I lines have periods in most cases in excess of 300 days (P-bar=330/sup d/ +- 83/sup d/). Interpreting our data in terms of kinematic studies by Feast (1963) suggests that the stars with Tc are Pop I and that variables without Tc are largely Pop II type stars

  1. Sup(99m) Technetium - labeled red blood cells 'in vitro'

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Souza Moura, I.N. de; Boasquevisque, E.M.

    1983-01-01

    A simple technique for the preparation of sup(99m) Tc labeled red blood cells using a comercial kit is described. To each 3ml of plain blood with anti-coagulant was added 1ml of solution of commercial kit with 6.8 μg of stannous chloride. This mixture was incubated in water bath, at 37 0 C, for 60 minutes. Then technetium-99m was added and the mixture was left for another ten minutes, in water bath, at 37 0 C. Under these conditions there was the best labeling of the red blood cells. Similar results were obtained with a solution of stannous chloride prepared freshly. The labeling is strong for 6.8 μg stannous chloride because the labeling was not removed by the several washes of the red blood cells or by the left in water bath. (Author) [pt

  2. Study of the catalytic activity of supported technetium catalysts

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Mikhailenko, I.E.; Pokorovskaya, O.V.

    1985-01-01

    The radioactive d metal 43 Tc 99 has catalytic properties in the synthesis of ammonia. For the purpose of reducing the quantity of the radioactive metal and of increasing the specific surface, the active component was applied to BaTiO 3 and gamma-Al 2 O 3 supports. This paper uses charcoal as a support and a table presents the catalytic activity of the samples during the synthesis of ammonia. X-ray diffractometric investigation of the catalysts was carried out with the use of Cu K /SUB alpha/ radiation. It is shown that the catalysts. The values of the specific rate constants of technetium in the catalysts. The values of the specific rate constants remain practically constant for all the catalyst samples studied, attesting to the absence of a specific metal-support interaction during the synthesis of ammonia

  3. Uptake of technetium from seawater by red abalone Haliotis rufescens

    International Nuclear Information System (INIS)

    Spies, R.B.

    1975-01-01

    Technetium accumulation from seawater by the abalone Haliotis rufescens was studied with 95 Tc. Concentration factors, uptake rates, steady state concentrations, and biological half-lives were determined experimentally for whole-body uptake. Whole-body concentration factors ranged from 135 to 205; biological half-life was 60 days. Changes in concentration factors were determined for six tissues during the uptake period. The highest activities were in the order of: digestive gland>gill>kidneys>heart>gonad>columnar muscle. Dead shells accumulated little activity compared to shells of living abalone. Gills and digestive system appear to be the routes of entry. Autoradiography shows that of the muscular tissues the outer edge of the foot and epipodium are the most active and the edible columnar muscle the least active. (author)

  4. Thallium-technetium-subtraction scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Adalet, I.; Hawkins, T.; Clark, F.; Wilkinson, R.

    1994-01-01

    Between 1983 and 1992 thallium-technetium subtraction scintigraphy (TTS) was performed on 74 patients with clinical and biochemical evidence of hyperparathyroidism. Twenty-five of the 53 investigations since 1988 were conducted on patients with renal failure with a suspicion of secondary hyperparathyroidism. In a retrospective study we have evaluated radioisotope scintigraphy for patients with adenoma and for renal failure patients with possible parathyroid hyperplasia. Thirty of 74 patients underwent neck exploration. Scintigraphy detected 17 of 24 parathyroid adenomas (sensitivity 71%). In contrast, in six renal patients who came to operation, scintigraphy localised only 5 of 20 hyperplastic parathyroid glands (sensitivity 25%) and in one renal patient we localised a parathyroid adenoma. A review of the literature shows low detection rates for hyperplasia by TTS to be a common observation. Based on these findings a rational approach is offered for parathyroid localisation in renal patients prior to neck exploration. (orig.)

  5. Synthesis of new Technetium 99 agents from aryl piperozine derivatives

    International Nuclear Information System (INIS)

    Zenati, Kaouther

    2012-01-01

    This work arises in the context of developing specific radiopharmaceuticals for serotoninergic 5-HT 1A receptors, for scintigraphic imaging by SPECT. these being involved in several neuropathology. Starting from new derivative of Technetium cytectrene bearing the methoxyphenyl piperazine moiety that have revealed an impressive brain uptake (2.47 pour cent ID/G), we thought to obtain an other radiocomplexe characterized by a more stable brain retention. To do this we added a spacer amino propyl to the first ligand 1-((2methoxyphenyl) piperazine carboxamide ferrocene, thus obtaining 1(3-aminopropyl) 4 (2-methoxyphenyl piperazine) ferrocene carboxamide. We report here the synthesis of the tricarbonyl 99mT c radioligand, its characterization and its biological study. The biodistribution is characterized by a very large uptake in the lungs and relatively slow depuration.Brain absorption is reduced compared to the analogue of origin with equivalent cerebral retention time.

  6. Studies of technetium chemistry. Pt.8. The regularities of the bond length and configuration of rhenium and technetium complexes in crystals

    International Nuclear Information System (INIS)

    Liu Guozheng; Liu Boli

    1995-01-01

    Some bond length regularities in MO 6 , MO-4, MX 5 α and MX 4 αβ moieties of technetium and rhenium compounds are summarized and rationalized by cavity model. The chemical properties of technetium and rhenium are so similar that their corresponding complexes have almost the same configuration and M-X bond lengths when they are in cavity-controlled state. Technetium and Rhenium combine preferably with N, O, F, S, Cl and Br when they are in higher oxidation states (>3), but preferably with P, Se etc. when they are in lower oxidation states ( 4 αβ is approximately constant; (2) the average M-X bond length of MX 6 varies moderately with the oxidation state of M; (3) the bond length of M-X trans to M-α in MX 5 α has a linear relationship with the angle

  7. Sorption of iodine, chlorine, technetium and cesium in soil

    International Nuclear Information System (INIS)

    Soederlund, M.; Lusa, M.; Lehto, J.; Hakanen, M.; Vaaramaa, K.

    2011-01-01

    The safety assessment of final disposal of spent nuclear fuel will include an estimate for the behavior of waste nuclides in the biosphere. As a part of this estimate also the sorption of radioactive iodine, chlorine, technetium and cesium in soil is to be considered. The chemistry and the sorption of these radionuclides in soils are described in this literature survey. Behavior of I-129, Cl-36 and Tc-99 in the environment is of great interest because of their long half-lives and relatively high mobilities. The importance of Cs-135 arises from its high content in spent nuclear fuel and long physical half-life, even though it is considered relatively immobile in soil. Factors affecting the migration and sorption of radionuclides in soils can be divided into elemental and soil specific parameters. The most important elemental factor is the speciation of the element, which is influenced by the soil redox potential, pH and complex forming ligands. Soil micro-organisms can either serve as sorbents for radionuclides or affect their speciation by altering the prevailing soil redox conditions. Soil organic matter content and mineral properties have a marked influence on the retention of radionuclides. The sorption of anionic radionuclides such as I-, Cl- and TcO 4 - is pronounced in the presence of organic matter. Clay minerals are known to bound cesium effectively. The effect of speciation of radioactive iodine, chlorine, technetium and cesium in soil is considered in this study, as well as the effect of soil micro-organisms, organic matter and mineral properties. (orig.)

  8. Preparation of L-asparagine complex with technetium

    International Nuclear Information System (INIS)

    Persano, S.C.M.

    1981-01-01

    The preparation of technetium chelated to L-asparagine is aimed at for obtention of potentially useful radiopharmaceutical in nuclear medicine. The reduction of pertechnetate anion ( 99 TcO - 4 and sup(99m) TcO - 4 ) using hydrazine as a reducing agent is studied with use of polarographic spectrophotometric and chromatographic methods. Spectrophotometric determination shows that the aqueous solution of amonium sup(-99m) Tc pertechnetate absorbs at 244, 248 and 290 nm. After reduction the species absorbs at 330 and near 495-530 nm. Polarographic measurements with 0,1 N NaOH electrolyte show a half-wave potential E sub(1/2 = -0,82 V for technetium +VII. After the addition of increasing amounts of hydrazine into a solution containing Tc+VII, the half wave potential shifts to more positives values, indicating the reduction of Tc+VII. Chromatographic determinations are in good agreement with polarographic analysis, emphatizing reduction of Tc+IV by hydrazine. The reduced 99 Tc shows ability of being incorporated into L-asparagine forming a cristalline compound with melting point 118.6 0 C. Infrared absorption spectrometry shows that amino and carboxyl groups are bound to the metal in this complex. The yield of sup(99m) Tc incorporation into L-asparagine at 60 0 C in 30 minutes is up to 95%. The labeled complex can be presented as a radiopharmaceutical product. Tissue distribution performed in groups of normal and bearing lymphoma Walker 256 Wistar rats (50-60) shows that the radiopharmaceutical concentrates seletively in the tumor and is fastly excreted by the kidney and it doesn't have significant affinity for any organ, being so adequate for the formation of tumoral images. (Authors) [pt

  9. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  10. Assessment of gastric motility using meal labeled with technetium-99m sulfur colloid

    International Nuclear Information System (INIS)

    Matolo, N.M.; Stadalnik, R.C.

    1983-01-01

    During a 2 year period, 83 patients with gastric motility problems were evaluated using radionuclide imaging. The patients presented with epigastric distress, postprandial fullness, pain, nausea, vomiting, and diarrhea; signs and symptoms suggestive of either gastroparesis or gastric outlet obstruction. Upper gastrointestinal series or endoscopy, or both, demonstrated no mechanical obstruction. After oral administration of a 300 g meal labeled with 600 muCi of technetium-99m sulfur colloid, a gastric emptying study consisting of serial images and data acquisition was performed. Of the patients studied, 52 had had peptic ulcer surgery, 17 were suspected of having gastroesophageal reflux, 8 were diabetic and suspected of having visceral enteropathy, and 6 had a history of irritable bowel syndrome. The normal mean gastric half emptying time was 77 +/- 16 minutes. Of the patients who had had gastric surgery, 90.4 percent had abnormal emptying: 69.2 percent had delayed gastric emptying and 21.2 percent had rapid gastric emptying time; 9.6 percent had normal emptying time. Of the gastroesophageal reflux group, all but two had normal gastric emptying time; 65 percent demonstrated gastroesophageal reflux within 15 minutes. Two of the patients with irritable bowel syndrome had prolonged emptying; the rest had normal emptying. All diabetic patients with gastroparesis had prolonged gastric emptying time, and all responded favorably to metoclopramide. Of the patients who previously had peptic ulcer surgery and had prolonged emptying time, 72 percent also responded favorably to metoclopramide. We conclude that radionuclide gastric imaging is a useful diagnostic test for the measurement of gastric emptying in patients with a variety of gastrointestinal motility disorders and may be helpful in assessing medical therapy and selecting those who may be candidates for surgery

  11. An investigation of the effect of the quantity of stannous ion on the quality of technetium-99m labelled albumin

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1981-01-01

    The importance of maintaining a low ratio of stannous ion to albumin molecules in order to obtain a high quality technetium-99m labelled albumin is demonstrated. It is further shown that the direct preparation of technetium-99m albumin by reduction of the technetium-99m pertechnetate with stannous ion inevitably leads to the contamination of the product with a certain amount of tin colloid which is also labelled with technetium-99m. It is demonstrated that this can be avoided by utilizing labelling techniques involving the initial formation of other technetium chelates which are less stable than the albumin complex under certain conditions, adding the albumin to that preparation, adjusting the conditions and thus allowing the albumin to become labelled with technetium-99m via an exchange with the original chelating agent. (author)

  12. CT of pleural abnormalities

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.)

  13. CT of pleural abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.).

  14. Neurologic abnormalities in murderers.

    Science.gov (United States)

    Blake, P Y; Pincus, J H; Buckner, C

    1995-09-01

    Thirty-one individuals awaiting trial or sentencing for murder or undergoing an appeal process requested a neurologic examination through legal counsel. We attempted in each instance to obtain EEG, MRI or CT, and neuropsychological testing. Neurologic examination revealed evidence of "frontal" dysfunction in 20 (64.5%). There were symptoms or some other evidence of temporal lobe abnormality in nine (29%). We made a specific neurologic diagnosis in 20 individuals (64.5%), including borderline or full mental retardation (9) and cerebral palsy (2), among others. Neuropsychological testing revealed abnormalities in all subjects tested. There were EEG abnormalities in eight of the 20 subjects tested, consisting mainly of bilateral sharp waves with slowing. There were MRI or CT abnormalities in nine of the 19 subjects tested, consisting primarily of atrophy and white matter changes. Psychiatric diagnoses included paranoid schizophrenia (8), dissociative disorder (4), and depression (9). Virtually all subjects had paranoid ideas and misunderstood social situations. There was a documented history of profound, protracted physical abuse in 26 (83.8%) and of sexual abuse in 10 (32.3%). It is likely that prolonged, severe physical abuse, paranoia, and neurologic brain dysfunction interact to form the matrix of violent behavior.

  15. Structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate and two molecules of inorganic phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaeok [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); Lin, Yih-Shyan [McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); Tsantrizos, Youla S. [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); Berghuis, Albert M., E-mail: albert.berghuis@mcgill.ca [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); McGill University, 3775 Rue University, Montreal, QC H3A 2B4 (Canada)

    2014-02-19

    A co-crystal structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate, YS0470, and two molecules of inorganic phosphate has been determined. The identity of the phosphate ligands was confirmed by anomalous diffraction data. Human farnesyl pyrophosphate synthase (hFPPS) produces farnesyl pyrophos@@phate, an isoprenoid essential for a variety of cellular processes. The enzyme has been well established as the molecular target of the nitrogen-containing bisphosphonates (N-BPs), which are best known for their antiresorptive effects in bone but are also known for their anticancer properties. Crystal structures of hFPPS in ternary complexes with a novel bisphosphonate, YS0470, and the secondary ligands inorganic phosphate (P{sub i}), inorganic pyrophosphate (PP{sub i}) and isopentenyl pyrophosphate (IPP) have recently been reported. Only the co-binding of the bisphosphonate with either PP{sub i} or IPP resulted in the full closure of the C-@@terminal tail of the enzyme, a conformational change that is required for catalysis and that is also responsible for the potent in vivo efficacy of N-BPs. In the present communication, a co-crystal structure of hFPPS in complex with YS0470 and two molecules of P{sub i} is reported. The unusually close proximity between these ligands, which was confirmed by anomalous diffraction data, suggests that they interact with one another, with their anionic charges neutralized in their bound state. The structure also showed the tail of the enzyme to be fully disordered, indicating that simultaneous binding of two P{sub i} molecules with a bisphosphonate cannot induce the tail-closing conformational change in hFPPS. Examination of homologous FPPSs suggested that this ligand-dependent tail closure is only conserved in the mammalian proteins. The prevalence of P{sub i}-bound hFPPS structures in the PDB raises a question regarding the in vivo relevance of P{sub i} binding to the function of the enzyme.

  16. Nitrido-technetium(V) complexes with amino acids: Preparation and X-ray crystal structure of the L-cysteinate ethyl ester technetium(V) complex

    International Nuclear Information System (INIS)

    Marchi, A.; Rossi, R.; Marvelli, L.; Bertolasi, V.

    1993-01-01

    Technetium-99m is the radionuclide of choice in diagnostic nuclear medicine due to its ideal photon energy of 140 keV and half-life of 6 h. Neutral, stable, and lipophilic technetium complexes with diamino dithiol ligands (DADT) have been widely studied as potential brain perfusion agents and a 99m Tc complex of N,N'-1,2-ethylenediylbis(L-cysteine diethyl ester) (L,L-ECD) has been proposed as a marker of regional cerebral blood flow. It crosses the blood brain barrier (BBB) and is retained in the brain owing to enzymatic hydrolysis of one ester group yielding to a more polar species. More recently, 99m Tc-cysteine complex has been evaluated in animal distribution studies for tumor diagnosis, but its chemical structure has not been determined. A large number of transition metal complexes with amino acids and peptides have been synthesized and structurally characterized to understand their interactions with proteins and antibodies, as well as biocatalytic processes, but only a limited number of rhenium and technetium compounds have been reported. Up to now, the only technetium complex to be characterized by X-ray analysis that contains amino acids as ligand is [TcO(L,L-ECD)]. The author's interest in the nitrido-technetium chemistry is due to the discovery of a new method for preparing radiopharmaceuticals containing the [ 99m Tc triple-bond N] 2+ core. In this communication the authors report the synthesis and characterization of nitrido-technetium complexes with L-cysteine ethyl ester (CYS-OEt), L-cysteine (CYS) and cysteamine (CSA) and the first X-ray crystal structure of a [TcN] 2+ -amino acid complex

  17. High-resolution structures of Lactobacillus salivarius transketolase in the presence and absence of thiamine pyrophosphate.

    Science.gov (United States)

    Lukacik, Petra; Lobley, Carina M C; Bumann, Mario; Arena de Souza, Victoria; Owens, Raymond J; O'Toole, Paul W; Walsh, Martin A

    2015-10-01

    Probiotic bacterial strains have been shown to enhance the health of the host through a range of mechanisms including colonization, resistance against pathogens, secretion of antimicrobial compounds and modulation of the activity of the innate immune system. Lactobacillus salivarius UCC118 is a well characterized probiotic strain which survives intestinal transit and has many desirable host-interaction properties. Probiotic bacteria display a wide range of catabolic activities, which determine their competitiveness in vivo. Some lactobacilli are heterofermentative and can metabolize pentoses, using a pathway in which transketolase and transaldolase are key enzymes. L. salivarius UCC118 is capable of pentose utilization because it encodes the key enzymes on a megaplasmid. The crystal structures of the megaplasmid-encoded transketolase with and without the enzyme cofactor thiamine pyrophosphate have been determined. Comparisons with other known transketolase structures reveal a high degree of structural conservation in both the catalytic site and the overall conformation. This work extends structural knowledge of the transketolases to the industrially and commercially important Lactobacillus genus.

  18. Sensitivity of {sup 99m}Tc-pyrophosphate scintigraphy in diagnosis of acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Hee; Park, Tai Que; Chae, Yoo Soon; Kim, Yang Sook [Maryknoll Hospital, Busan (Korea, Republic of)

    1991-01-15

    To assess the difference of the diagnostic sensitivity of {sup 99m}Tc-Pyrophosphate (PYP) myocardial scintigraphy in acute transmural infarction and acute subendocardial infarction, we analyzed 38 patients with a confirmed transmural infarct, 10 with a subendocardial infarct, 2 with old myocardial infarct, and 10 with other cardiovascular disease (2 unstable angina, 6 stable angina, 1 Prinzmetal angina, and 1 atrial fibrillation) according to Berman's criteria for scintigraphic assessment and then come to conclusion; When only focal myocardial uptake wa used as a criteria for positivity, the diagnostic sensitivity of {sup 99m}Tc-PYP scintigraphy in acute subendocardial myocardial infarction was only 40% (4/10) compared with 86.8% (33/38) of acute transmural myocardial infarction. There was no case that was interpreted as focal myocardial uptake in 2 old myocardial infarction and 10 other cardiovascular disease. The incidence of complication was higher in doughnut pattern of myocardial uptake 50% (3/6) than in non-doughnut focal patterns 19.4% (6/31). It is concluded that focal myocardial uptake is a sensitive indicator suggesting acute myocardial necrosis and that {sup 99m}Tc-PYP myocardial scintigraphy is a sensitive technique for diagnosing acute transmural myocardial infarction, but a insensitive method in acute subendocardial infarction, and that the doughnut pattern of myocardial uptake an provide clues to the patient's future course.

  19. Biomineralizing synthesis of mesoporous hydroxyapatite-calcium pyrophosphate polycrystal using ovalbumin as biosurfactant

    International Nuclear Information System (INIS)

    Zhao Hongshi; He Wen; Wang Yingjun; Yue Yuanzheng; Gao Xingguo; Li Zhengmao; Yan Shunpu; Zhou Weijia; Zhang Xudong

    2008-01-01

    Mesoporous polycrystals of hydroxyapatite-calcium pyrophosphate (HA-CPP) are synthesized via a biomineralizing route using ovalbumin as natural biosurfactant. The mesoporous structure of HA-CPP is characterized by means of X-ray diffraction (XRD), N 2 adsorption-desorption isotherms (NADI), Fourier transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM), atom force microscopy (AFM), polarization microscopy (PLM) and stereomicroscopy. The results show that the crystalline grains with an average diameter of 13.2 nm are uniformly distributed along the protein molecule chains, and this results in microsphere-like particles with diameters of 200-300 nm. The highly ordered pores involved in microspheres are found to be approximately 6.6 nm by small-angle XRD. The formation of lyotropic calcium liquid crystal (CLC) plays a key role in the formation and stabilization of the mesoporous structure. A schematic illustration is used to reveal the mechanism of protein-medicated HA-CPP biomineralization, which employs the protein tertiary structure to explain the formation of the porous particles

  20. Scintigraphic diagnosis of experimentally induced pericarditis in dogs using 99sup(m)Tc-labelled pyrophosphate

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubizek, J.; Simon, J.; Veverkova, O.; Karlova Universita, Hradec Kralove

    1981-01-01

    In the present paper the possibilities of scintigraphic diagnosis of experimental pericarditis are discussed. Pericarditis was induced by either talc or formaldehyde intrapericardially. In all animals the administration of talc as well as formaldehyde produced inflammatory changes which were more serious after formaldehyde. The scan of the talc pericarditis was carried out on the 7th day after operation and of the formaldehyde pericarditis on the 3rd, 7th and 14th day. No positive scintigraphic finding was made in any of the experimental animals, apart from a massive incorporation in the operation scars. The counting of radioactive impulses after the exstirpation of the tissue samples confirmed the scintigraphic findings. Statistical evaluation did not reveal any essential difference between the accumulation of the radiopharmaceutical into the pericarditis as well as into the pericardial bag in comparison with the control animals. Although our model does not exactly reflect the situation of patients suffering from pericarditis it may be assumed that pyrophosphate scintigraphy is not suitable for the diagnosis of acute pericarditis in clinical practice. (orig.) [de

  1. Novel phosphate-activated macrophages prevent ectopic calcification by increasing extracellular ATP and pyrophosphate

    Science.gov (United States)

    Villa-Bellosta, Ricardo; Hamczyk, Magda R.; Andrés, Vicente

    2017-01-01

    Purpose Phosphorus is an essential nutrient involved in many pathobiological processes. Less than 1% of phosphorus is found in extracellular fluids as inorganic phosphate ion (Pi) in solution. High serum Pi level promotes ectopic calcification in many tissues, including blood vessels. Here, we studied the effect of elevated Pi concentration on macrophage polarization and calcification. Macrophages, present in virtually all tissues, play key roles in health and disease and display remarkable plasticity, being able to change their physiology in response to environmental cues. Methods and results High-throughput transcriptomic analysis and functional studies demonstrated that Pi induces unpolarized macrophages to adopt a phenotype closely resembling that of alternatively-activated M2 macrophages, as revealed by arginine hydrolysis and energetic and antioxidant profiles. Pi-induced macrophages showed an anti-calcifying action mediated by increased availability of extracellular ATP and pyrophosphate. Conclusion We conclude that the ability of Pi-activated macrophages to prevent calcium-phosphate deposition is a compensatory mechanism protecting tissues from hyperphosphatemia-induced pathologic calcification. PMID:28362852

  2. Calcium pyrophosphate dihydrate and hydroxyapatite crystals in a patient with rheumatoid arthritis: Acase report

    Directory of Open Access Journals (Sweden)

    Shereen R Kamel

    2017-01-01

    Full Text Available The association between rheumatoid arthritis (RA and calcium pyrophosphate dihydrate (CPPD crystal deposits can now be easily identified by MSUS, which is a noninvasive technique that can be applied to patients with painful joints and enthesis that are unexplained by rheumatoid activity. In this paper, we report an Egyptian case of a 51-year-old man who had rheumatoid arthritis since 7 years and developed bilateral knee and heel pain of 1.5 months’ duration with gradual onset and progressive course. Radiography revealed features of RA in both hands, as well as features of severe osteoarthritis in both knees with no signs of chondrocalcinosis. Ultrasonography of the joints, Achilles tendon, and plantar fascia detected knee, Achilles tendon, and plantar fascia calcifications, which are characteristic of CPPD, and supraspinatus calcification, which is characteristic of hydroxyapatite (HA deposition. Further investigations revealed no evidence of metabolic disorders. CPPD and HA crystals were identified in his synovial fluid. Subclinical affection with CPPD and HA crystals in RA can be easily detected by ultrasonography, which allows early management to prevent future attacks in RA patients that could lead to exacerbation of joint symptoms that may be missed as rheumatoid disease activity. Diet control and colchicine treatment may be more effective if started early before exacerbation.

  3. Control of plant phosphate homeostasis by inositol pyrophosphates and the SPX domain.

    Science.gov (United States)

    Jung, Ji-Yul; Ried, Martina K; Hothorn, Michael; Poirier, Yves

    2018-02-01

    Proteins containing a SPX domain are involved in phosphate (Pi) homeostasis, including Pi transport and adaptation to Pi deficiency. The SPX domain harbors a basic surface binding Pi at low affinity and inositol pyrophosphates (PP-InsPs) at high affinity. Genetic and biochemical studies revealed that PP-InsPs serve as ligands for the SPX domain. Residues in the PHO1 SPX domain involved in PP-InsPs binding are critical for its Pi export activity, and the interaction between SPX proteins and the PHR1 transcription factor, which results in PHR1 inactivation, is promoted by PP-InsPs. Changes in PP-InsPs levels in response to Pi deficiency may thus contribute to the adaptation of plants to stress via the modulation of the activity of SPX-containing proteins and their interactors. Modulating PP-InsP levels or the affinity/specificity of the SPX domain for PP-InsP could potentially be used to engineer crops to maintain high yield under reduced Pi fertilizer input. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Kinetics of pyrophosphate-driven proton uptake by acidocalcisomes of Leptomonas wallacei

    International Nuclear Information System (INIS)

    Moraes Moreira, Bernardo Luiz; Soares Medeiros, Lia Carolina A.; Miranda, Kildare; Souza, Wanderley de; Hentschel, Joachim; Plattner, Helmut; Barrabin, Hector

    2005-01-01

    In this work, we show the kinetics of pyrophosphate-driven H + uptake by acidocalcisomes in digitonin-permeabilized promastigotes of Leptomonas wallacei. The vacuolar proton pyrophosphatase activity was optimal in the pH range of 7.5-8.0, was inhibited by imidiodiphosphate, and was completely dependent on K + and PPi. H + was released with the addition of Ca 2+ , suggesting the presence of a Ca 2+ /H + antiport. In addition, X-ray elemental mapping associated with energy-filtering transmission electron microscopy showed that most of the Ca, Na, Mg, P, K, Fe, and Zn were located in acidocalcisomes. L. wallacei immunolabeled with antibodies against Trypanosoma cruzi pyrophosphatase show intense fluorescence in cytoplasmatic organelles of size and distribution similar to the acidocalcisomes. Altogether, the results show that L. wallacei acidocalcisomes possess a H + -pyrophosphatase with characteristics of type I V-H + -PPase. However, we did not find any evidence, either for the presence of H + -ATPases or for Na + /H + exchangers in these acidocalcisomes

  5. Pyrophosphate levels strongly influence ascorbate and starch content in tomato fruit

    Directory of Open Access Journals (Sweden)

    Sonia eOsorio

    2013-08-01

    Full Text Available Ascorbate (vitamin C deficiency leads to low immunity, scurvy, and other human diseases and is therefore a global health problem. Given that plants are major ascorbate sources for humans, biofortification of this vitamin in our foodstuffs is of considerable importance. Ascorbate is synthetized by a number of alternative pathways: (i from the glycolytic intermediates D-glucose-6P (the key intermediates are GDP-D-mannose and L-galactose, (ii from the breakdown of the cell wall polymer pectin which uses the methyl ester of D-galacturonic acid as precursor and (iii from myo-inositol as precursor via myo-inositol oxygenase. We report here the engineering of fruit-specific overexpression of a bacterial pyrophosphatase, which hydrolyzes the inorganic pyrophosphate (PPi to orthophosphate (Pi. This strategy resulted in increased vitamin C levels up to 2.5 fold in ripe fruit as well as increasing in the major sugars, sucrose and glucose, yet decreasing the level of starch. When considered together, these finding indicate an intimate linkage between ascorbate and sugar biosynthesis in plants. Moreover, the combined data reveal the importance of PPi metabolism in tomato fruit metabolism and development.

  6. Photoaffinity labeling of cAMP-dependent protein kinase by 4-azido-2-nitrophenyladenylyl pyrophosphate

    International Nuclear Information System (INIS)

    Johnson, D.R.; Ho, H.T.; Wong, S.S.

    1986-01-01

    A photoaffinity analogue of ATP, 4-azido-2-nitrophenyl-adenylyl pyrophosphate (ANAP) has been synthesized to investigate the topographical interaction between the catalytic and the regulatory subunits of the bovine heart type II cAMP-dependent protein kinase. The synthesis involves coupling of 4-azido-2-nitrophenyl phosphate with adenosine 5'-monophosphomorpholidate. ANAP has an absorption maximum at 260 nm (molar absorptivity = 35.4 x 10 3 M -1 cm -1 ) and a shoulder at 320 nm. Kinetically, ANAP inhibits the enzyme competitively against ATP with a Ki of 0.37 mM. The catalytic subunit is inactivated by ANAP upon photolysis in the presence of magnesium ion. ATP protects the enzyme from photoinactivation but the regulatory subunit does not. Gel electrophoretic analysis of the enzyme labeled by [ 14 C]ANAP shows that the photoincorporated ANAP is associated mainly with the catalytic subunit, even when the regulator dimer is in twelve fold excess. Little or no ANAP is found incorporated into the regulator subunit. The data suggest that the photoreactive portion of ANAP does not lie within reach of the regulatory protein when the analogue is bound to the catalytic subunit

  7. Clinical evaluation of skeletal scintigraphy with sup(99m)Tc-pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Sugiura, I; Sasaki, T; Kaneko, M; Watanabe, M [Nagoya Univ. (Japan). Faculty of Medicine

    1975-04-01

    Following about 10 mCi of intravenous administration of sup(99m)Tc-pyrophosphate, skeletal scintiphotography was performed in various skeletal diseases. Skeletal scintiphotograms were taken at about 2 to 3 hours after the administration of the radioisotope with Nuclear Chicago Rho/Gamma III scinticamera. The frontal, occipital and bilateral views of the skull, posterior and lateral views of the spine, anterior and posterior views of ribs, anterior and posterior views of the pelvis and either anterior and posterior views of extremities were scintiphotographed. 17 cases were studied of primary bone tumor (7 benign, 10 malignant), 20 cases of osseous metastasis and 20 cases of non-tumorous conditions. In malignant and benign bone tumors radioactivity is increased at the site of bony changes except for myeloma and leukaemia. In osseous metastasis radioactivity is increased at the site of lesion, even in the early stage. In non-tumorous conditions, radioactivity is also increased at the site of bony changes except for old healed osteomyelitis, old healed tuberculosis of bone and osteoporosis in Cushing's syndrome.

  8. Passivation of Cu-Zn alloy on low carbon steel electrodeposited from a pyrophosphate medium

    Science.gov (United States)

    Yavuz, Abdulcabbar; Yakup Hacıibrahimoğlu, M.; Bedir, Metin

    2018-01-01

    The motivation of this study is to understand whether zinc-based alloy also has a passivation behaviour similar to zinc itself. Cu-Zn alloys were electrodeposited potentiostatically from a pyrophosphate medium on a carbon steel electrode and their corrosion behaviours were studied. Pt and carbon steel electrodes were used in order to examine the corrosion/passivation behaviour of bare Cu, bare Zn and Cu-Zn alloy coatings. The passivation behaviour of all brass-modified electrodes having Zn content between 10% and 100% was investigated. The growth potential affects the morphology and structure of crystals. The brass coatings are more porous than their pure components. The crystalline structure of Cu-Zn alloys can be obtained by changing the deposition potential. The zinc content in brass increases when the deposition voltage applied decreases. However, the growth potential and the ratio of zinc in brass do not affect the passivation behaviour of the resulting alloys. The coatings obtained by applying different growth potentials were immersed in tap water for 24 h to compare their corrosion behaviours with carbon steel having pitting formation.

  9. Prognostic value of technetium-99m-labeled single-photon emission computerized tomography in the follow-up of patients after their first myocardial revascularization surgery

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2003-01-01

    Full Text Available OBJECTIVE: To assess the prognostic value of Technetium-99m-labeled single-photon emission computerized tomography (SPECT in the follow-up of patients who had undergone their first myocardial revascularization. METHODS: We carried out a retrospective study of 280 revascularized patients undergoing myocardial scintigraphy under stress (exercise or pharmacological stress with dipyridamole and at rest according to a 2-day protocol. A set of clinical, stress electrocardiographic and scintigraphic variables was assessed. Cardiac events were classified as "major" (death, infarction, unstable angina and "any" (major event or coronary angioplasty or new myocardial revascularization surgery. RESULTS: Thirty-six major events occurred as follows: 3 deaths, 11 infarctions, and 22 unstable anginas. In regard to any event, 22 angioplasties and 7 new surgeries occurred in addition to major events, resulting a total of 65 events. The sensitivity of scintigraphy in prognosticating a major event or any event was, respectively, 55% and 58%, showing a negative predictive value of 90% and 83%, respectively. Diabetes mellitus, inconclusive stress electrocardiography, and a scintigraphic visualization of left ventricular enlargement were significant variables for the occurrence of a major event. On multivariate analysis, abnormal myocardial scintigraphy was a predictor of any event. CONCLUSION: Myocardial perfusion tomography with Technetium-99m may be used to identify high-risk patients after their first myocardial revascularization surgery.

  10. Analysis of Technetium Species and Fractions in Natural Seaweed Using Biochemical Separation and ICP-MS Measurement

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Qiao, Jixin

    2016-01-01

    An extremely high accumulation and retention of technetium in marine plants, especially brown seaweed, makes it a unique bioindicator of technetium. In the present work, a novel approach was developed for the speciation analysis of technetium in seaweed, wherein a series of biochemical separations....... Besides the inorganic species of TcO4-, most of technetium (>75%) combined with organic components of seaweed such as algin, cellulose, and pigment. This investigation could provide important fundamental knowledge for studying the processes and mechanisms of 99Tc accumulation in the natural seaweed....

  11. Studies on quality control of technetium-99m labelling kits

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo

    1987-12-01

    Various experiments for the quality control of Tc-99m labelled radiopharmaceuticals such as Tc-99m-phytate, Tc-99m-MDP, Tc-99m-Tin Colloid, Tc-99m-DISIDA, Tc-99m-DTPA,Tc-99m-DMSA, Tc-99m-Gulcoheptonate, TC-99m-Pyrophosphate, Tc-99m-HSA, and Tc-99m-HAM were carried out. Labelling yield and radiochemical purity of each of the instant labelling kit of KAERI made were determined by means of radiochromatography. Biodistribution in mice and whole body or specific organ imagings of rabbits were also carried out and discussed the relationship between the data of biodistributions and radiochemical purities. Labelling yeilds were above 98% for almost all of the labelling kits. The radio-pharmaceuticals were accumulated at each target organ with moderate specifities. In case of radiochemical purity of above 98%, the biodistribution and gamma imagings were also better. The kits of MDP and DISIDA were stable at least for four moths while the other kits at least eight months. (Author)

  12. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    International Nuclear Information System (INIS)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.; Kass, R.M.; Raymond, M.J.; Garcia, E.V.; Chaux, A.; Matloff, J.M.; Berman, D.S.

    1984-01-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and left ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers

  13. Bone marrow immunoscintigraphy using technetium-99m anti-granulocyte antibody in multiple myeloma

    International Nuclear Information System (INIS)

    Sohn, Sang-Kyun; Kim, Dong-Hwan; Park, So-Hyang; Ahn, Byeong-Cheol; Lee, Sang-Woo; Chun, Kyung-Ah; Kim, Jung-Gyun; Lee, Kyu Bo; Lee, Jaetae; Song, Hong-Suk

    2002-01-01

    Conventional skeletal radiography and bone scan have certain limitations in the initial evaluation of bone and bone marrow lesions in multiple myeloma (MM). In this study we investigated the value of bone marrow immunoscintigraphy (BMIS) using anti-granulocyte monoclonal antibody (AGA) for the diagnosis of bone involvement of MM, in comparison with bone scan and skeletal radiography. Whole-body BMIS using technetium-99m-labelled AGA was performed in 22 MM patients (15 male, 7 female) and the imaging findings compared with those of skeletal radiography and 99m Tc-methylene diphosphonate bone scan. The findings of bone marrow aspiration and serum biochemical findings were also compared with BMIS findings. Abnormal findings of BMIS were defined as presence of a focal photon defect in the axial skeleton or expansion of peripheral bone marrow. A total of 124 focal lesions were detected in 19 subjects (86%) by skeletal radiography, bone scan or BMIS. BMIS detected 92 lesions (74%) in 19 subjects, whereas skeletal radiography detected 58 focal lesions (47%) in 14 and bone scan 40 lesions (32%) in 11. Fifty-one (41%) of the 124 lesions were only seen on BMIS. Spine and pelvic lesions were better visualised by BMIS, whereas skull lesions were better seen with skeletal radiography, and bone scan detected more lesions in the ribs. Marrow expansion was noted in 15 subjects (68%) on BMIS, and its grade correlated with marrow cellularity and myeloma cell percentage in bone marrow aspirates (P=0.0055 and P=0.0541, respectively). BMIS revealed abnormal lesions in one of three stage II patients and 17 out of 19 stage III patients. The number of lesions of the thoracolumbar vertebrae on BMIS was correlated with cellularity (P=0.0393), but not with myeloma cell percentage (P=0.1262). These findings suggest that the results of BMIS with 99m Tc-labelled AGA correlate with clinical stage, and thus reflect the functional status of bone marrow in MM patients. BMIS might be useful for the

  14. Nitrofurantoin and congenital abnormalities

    DEFF Research Database (Denmark)

    Czeizel, A.E.; Rockenbauer, M.; Sørensen, Henrik Toft

    2001-01-01

    or fetuses with Down’s syndrome (patient controls), 23 (2.8%) pregnant women were treated with nitrofurantoin. The above differences between population controls and cases may be connected with recall bias, because the case-control pair analysis did not indicate a teratogenic potential of nitrofurantoin use......Objective: To study human teratogenic potential of oral nitrofurantoin treatment during pregnancy. Materials and Methods: Pair analysis of cases with congenital abnormalities and matched population controls in the population-based dataset of the Hungarian Case-Control Surveillance of Congenital...... during the second and the third months of gestation, i.e. in the critical period for major congenital abnormalities. Conclusion: Treatment with nitrofurantoin during pregnancy does not present detectable teratogenic risk to the fetus....

  15. Neurological abnormalities predict disability

    DEFF Research Database (Denmark)

    Poggesi, Anna; Gouw, Alida; van der Flier, Wiesje

    2014-01-01

    To investigate the role of neurological abnormalities and magnetic resonance imaging (MRI) lesions in predicting global functional decline in a cohort of initially independent-living elderly subjects. The Leukoaraiosis And DISability (LADIS) Study, involving 11 European centres, was primarily aimed...... at evaluating age-related white matter changes (ARWMC) as an independent predictor of the transition to disability (according to Instrumental Activities of Daily Living scale) or death in independent elderly subjects that were followed up for 3 years. At baseline, a standardized neurological examination.......0 years, 45 % males), 327 (51.7 %) presented at the initial visit with ≥1 neurological abnormality and 242 (38 %) reached the main study outcome. Cox regression analyses, adjusting for MRI features and other determinants of functional decline, showed that the baseline presence of any neurological...

  16. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  17. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Konirova, R.; Vecernik, P.; Jedinakova-Krizova, V.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. It is generally known that bentonite materials show an excellent cation-exchange capacity and, on the other hand, a poor uptake of anions. Technetium occurs under aerobic conditions in its most stable oxidation state (+VII) as pertechnetate, which makes a question of its sorption on bentonite more complex when compared with e.g. Cs + or Sr 2+ . To increase the K d values for technetium sorption on bentonite, it is necessary to carry out the experiments under anaerobic conditions in the presence of reducing agent, which is capable to lower the oxidation state of technetium which enables its successful immobilization. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing conditions. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ , Fe) with bentonite, the effect of solid:aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. (authors)

  18. Abnormal pressures as hydrodynamic phenomena

    Science.gov (United States)

    Neuzil, C.E.

    1995-01-01

    So-called abnormal pressures, subsurface fluid pressures significantly higher or lower than hydrostatic, have excited speculation about their origin since subsurface exploration first encountered them. Two distinct conceptual models for abnormal pressures have gained currency among earth scientists. The static model sees abnormal pressures generally as relict features preserved by a virtual absence of fluid flow over geologic time. The hydrodynamic model instead envisions abnormal pressures as phenomena in which flow usually plays an important role. This paper develops the theoretical framework for abnormal pressures as hydrodynamic phenomena, shows that it explains the manifold occurrences of abnormal pressures, and examines the implications of this approach. -from Author

  19. Synthesis and Properties of Metallic Technetium and Technetium-Zirconium Alloys as Transmutation Target and Radioactive waste storage form in the UREX+1 Process

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Thomas [Idaho State University/Idaho National Laboratory, 1776 Science Center Drive, Idaho Falls, ID 83402 (United States)]|[Harry Reid Center, University Nevada - Las Vegas, 4505 Maryland Parkway, Las Vegas, NV (United States); Poineau, Frederic; Czerwinski, Kenneth R. [Harry Reid Center, University Nevada - Las Vegas, 4505 Maryland Parkway, Las Vegas, NV (United States)

    2008-07-01

    In the application of UREX+1 process, technetium will be separated together with uranium and iodine within the first process step. After the separation of uranium, technetium and iodine must be immobilized by their incorporation in a suitable waste storage-form. Based on recent activities within the AFCI community, a potential candidate as waste storage form to immobilize technetium is to alloy the metal with excess zirconium. Alloys in the binary Tc-Zr system may act as potential transmutation targets in order to transmute Tc-99 into Ru-100. We are presenting first results in the synthesis of metallic technetium, and the synthesis of equilibrium phases in the binary Tc-Zr system at 1400 deg. C after arc-melting and isothermal annealing under inert conditions. Samples were analyzed using X-ray powder diffraction, Rietveld analysis, scanning electron microscopy, and electron probe micro-analysis, which allows us to construct the binary Tc-Zr phase diagram for the isothermal section at 1400 deg. C. (authors)

  20. Development of a remote spectroelectrochemical sensor for technetium as pertechnetate

    Science.gov (United States)

    Monk, David James

    Subsurface contamination by technetium (Tc) is of particular concern in the monitoring, characterization, and remediation of underground nuclear waste storage tanks, processing areas, and associated surroundings at the Hanford Site and other U.S. DOE sites nationwide. The concern over this radioactive element arises for two reasons. First, its most common isotope, 99Tc, has an extremely long lifetime of 2.15 x 105 years. Second, it's most common chemical form in environmental conditions, pertechnetate (TcO4-), exhibits very fast migration through soils and readily presents itself to any nearby aquifer. Standard procedures of sampling and analysis in a laboratory prove to be slow and costly in the case of subsurface contamination by radioactive materials. It is highly desirable to develop sensors for these materials that possess the capability of either in-situ or on-site placement for continuous monitoring or immediate analysis of collected samples. These sensors need to possess adequate detection limit and selectivity, rapid response, reversibility (many measurements with one sensor), the ability to perform remotely, and ruggedness. This dissertation describes several areas of the continued work toward a sensor for 99Tc as TcO4-. Research initially focused on developing spectroelectrochemical instrumentation and a disposable sensing element, engineered to address the need to perform remote measurements. The instrument was then tested using samples containing 99Tc, resulting in the development of ancillary equipment and techniques to address concerns associated with performing experiments on radioactive materials. In these tests, the electrochemistry of TcO4 - was demonstrated to be irreversible. Electrochemical reduction of TcO4- on a bare or polymer modified electrode resulted in the continuous build up of technetium oxide (TcO2) on the electrode surface. This TcO2 formed in visual quantities in these films during electrochemistry, and proved to be non-ideal for

  1. Speciation of technetium in acidic media: effect of α radiations

    International Nuclear Information System (INIS)

    Denden, Ibtihel

    2013-01-01

    This project is part of the fundamental study of technetium speciation in highly acidic medium. The behaviour of technetium in HTFMS was carried out in the absence then in the presence of a irradiation. Given these two different conditions, spectrophotometric results of Tc(VII) reduction are similar. XAS analysis indicates the formation of a cyclic dimer of Tc(IV) complexed to triflate ligands and formulated asTc 2 O 2 (CF 3 SO 3 ) 4 (H 2 O)4. This compound is linearized to Tc(IV)-O-Tc(IV) with the increase of HTFMS concentration. At high concentration of HTFMS +98% (11.15 M), the protonated species TcO 3 (OH)(H 2 O) 2 which is formed in the absence of external ionizing radiations, is reduced to the V oxidation state under a irradiation. Structural characterization by EXAFS spectroscopy and DFT calculations suggests the formation of monomer species of Tc(V)-triflate complexes where [OTc(F 3 CSO 3 ) 2 (H 2 O)2] + and [OTc(F 3 CSO 3 ) 2 (OH) 2 ] - compounds were proposed. In concentrated H 2 SO 4 (CH 2 SO 4 ≥ 12 M), a-radiolysis experiments of Tc(VII) were performed in order to compare the radiolytic behaviour of Tc(VII) in both comparable media HTFMS and H 2 SO 4 . XANES studies show that radiolytic reduction of Tc(VII) leads to the formation of Tc(V)-Tc(VII) mixture in H 2 SO 4 13 M and just Tc(V) in 18 M of H 2 SO 4 . The analysis of EXAFS spectra is consistent with the formation of [TcO(HSO 4 ) 3 (H 2 O) 2 ] and [TcO(HSO 4 )3(H 2 O)(OH)] - monomer complexes in H 2 SO 4 13 M and [Tc(HSO 4 ) 3 (SO 4 )(H 2 O)] and [Tc(HSO 4 ) 3 (SO 4 )(OH)] - species at 18 M of H 2 SO 4 . (author)

  2. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Morse, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO4-). Perrhenate (ReO4-) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of

  3. Relative bioavailability of micronized, dispersible ferric pyrophosphate added to an apple juice drink.

    Science.gov (United States)

    Roe, Mark A; Collings, Rachel; Hoogewerff, Jurian; Fairweather-Tait, Susan J

    2009-03-01

    Food iron fortification is a sustainable and relatively simple strategy to reduce/prevent iron deficiency but is a challenge for the food industry because of possible adverse organoleptic changes caused by the added iron. A micronized dispersible ferric pyrophosphate, trademarked as SunActive Fe, has recently been developed. SunActive Fe has a small particle size, is water soluble and may be suitable for fortifying liquid products. To determine the relative bioavailability of SunActive Fe and its suitability for addition to pure apple juice. Iron absorption from SunActive Fe added to pure apple juice (Minute Maid) was compared with absorption from ferrous sulphate, a highly bioavailable form of iron, in 15 women with relatively low iron stores. Both forms of iron were enriched with an iron stable isotope and iron absorption from the apple juice drinks was calculated from the isotopic enrichment of red blood cells 14 days after the last test meal. Although mean absorption of iron from SunActive Fe was significantly lower than from ferrous sulphate (5.5% compared with 9.1%), the mean bioavailability of SunActive Fe iron relative to ferrous sulphate was 0.6, indicating that it is a good source of bioavailable iron. Iron Absorption from SunActive Fe was positively correlated (r = 0.97, P = 0.01) with absorption from ferrous sulphate, and negatively correlated with serum ferritin concentration (ferrous sulphate r = -0.81, P apple juice and is a potentially useful fortificant for liquid food products.

  4. Ultrasonographic findings of Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease.

    Science.gov (United States)

    Ellabban, Abdou S; Kamel, Shereen R; Abo Omar, Hanaa A S; El-Sherif, Ashraf M H; Abdel-Magied, Rasha A

    2012-04-01

    The aims of the study were to detect the frequency of involvement of the Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease (CPPD) by high-frequency gray-scale ultrasonography (US) and power Doppler sonography (PDS) and to correlate these findings with demographic and clinical data. Two groups of patients were enrolled: group I (38 patients with CPPD) and group II (22 patients with knee OA). US/PDS examination of the heels was performed to both groups. In the CPPD group, US/PDS examination of the Achilles tendon revealed: calcification in 57.9%, enthesophytosis in 57.9%, enthesopathy in 23.7%, vascular sign in 21%, bursitis in 13.2%, and cortical bone irregularity in 10.5%. US/PDS examination of plantar fascia in the CPPD group revealed: calcification in 15.8%, cortical bone irregularity in 78.9%, enthesophytosis in 60.5%, and planter fasciitis in 42.1%. In patients with CPPD, age was significantly correlated with enthesophytosis and deep retrocalcaneal bursitis (p = 0.01 and p = 0.04, respectively). Heel tenderness and posterior talalgia were significantly correlated with Achilles tendon enthesopathy, vascular sign, and deep retrocalcaneal bursitis (p = 0.0001 for each). Inferior talalgia was significantly correlated with plantar fasciitis (p = 0.0001). The sensitivity of ultrasonography for detection of calcifications in Achilles tendon and plantar fascia was 57.9% and 15.8%, respectively, and the specificity was 100% for both. To conclude, ultrasonographic Achilles tendon and plantar fascia calcifications are frequent findings in patients with CPPD. These calcifications have a high specificity and can be used as a useful indirect sign of CPPD.

  5. Membrane Topology and Biochemical Characterization of the Escherichia coli BacA Undecaprenyl-Pyrophosphate Phosphatase.

    Directory of Open Access Journals (Sweden)

    Guillaume Manat

    Full Text Available Several integral membrane proteins exhibiting undecaprenyl-pyrophosphate (C55-PP phosphatase activity were previously identified in Escherichia coli that belonged to two distinct protein families: the BacA protein, which accounts for 75% of the C55-PP phosphatase activity detected in E. coli cell membranes, and three members of the PAP2 phosphatidic acid phosphatase family, namely PgpB, YbjG and LpxT. This dephosphorylation step is required to provide the C55-P carrier lipid which plays a central role in the biosynthesis of various cell wall polymers. We here report detailed investigations of the biochemical properties and membrane topology of the BacA protein. Optimal activity conditions were determined and a narrow-range substrate specificity with a clear preference for C55-PP was observed for this enzyme. Alignments of BacA protein sequences revealed two particularly well-conserved regions and several invariant residues whose role in enzyme activity was questioned by using a site-directed mutagenesis approach and complementary in vitro and in vivo activity assays. Three essential residues Glu21, Ser27, and Arg174 were identified, allowing us to propose a catalytic mechanism for this enzyme. The membrane topology of the BacA protein determined here experimentally did not validate previous program-based predicted models. It comprises seven transmembrane segments and contains in particular two large periplasmic loops carrying the highly-conserved active site residues. Our data thus provide evidence that all the different E. coli C55-PP phosphatases identified to date (BacA and PAP2 catalyze the dephosphorylation of C55-PP molecules on the same (outer side of the plasma membrane.

  6. Effect of inorganic additive sodium pyrophosphate tetrabasic on positive electrolytes for a vanadium redox flow battery

    International Nuclear Information System (INIS)

    Park, Se-Kook; Shim, Joonmok; Yang, Jung Hoon; Jin, Chang-Soo; Lee, Bum Suk; Lee, Young-Seak; Shin, Kyoung-Hee; Jeon, Jae-Deok

    2014-01-01

    Sodium pyrophosphate tetrabasic (SPT) is employed as an inorganic additive in the positive electrolyte of a vanadium redox flow battery (VRFB) to improve its long-term stability and electrochemical performance. The results of precipitation tests show that the long-term stability of positive electrolytes (2 MV(V) solution in 4 M total sulfates with 0.05 M SPT additive) is improved compared to the blank one. UV-vis and cyclic voltammetry (CV) measurements also suggest that the addition of SPT can effectively delay the formation of precipitation in positive electrolytes, and no new substances are formed in V(V) electrolytes with SPT. The calcined precipitates extracted from the electrolytes with and without a SPT additive are identified as V 2 O 5 by X-ray diffraction (XRD) analysis. A VRFB single-unit cell employing positive electrolytes with an additive exhibits the high energy efficiency of 74.6% at a current density of 40 mA cm 2 at the 500 th cycle at 20°C, compared to 71.8% for the cell employing the electrolyte without an additive. Moreover, the cell employing the electrolyte with an additive exhibits less discharge capacity fading during cycling in comparison with the pristine one. The disassembled cell without an additive shows a large number of V 2 O 5 precipitation particles on the felt electrode after 500 cycles. Meanwhile, the felt electrode of the cell with an additive has little precipitation. That precipitation gives rise to an imbalance between the positive and negative half-cell electrolytes, which results in a significant capacity loss. The additive has shown positive results under limited laboratory short-term and small-scale conditions

  7. Identification of the inorganic pyrophosphate metabolizing, ATP substituting pathway in mammalian spermatozoa.

    Science.gov (United States)

    Yi, Young-Joo; Sutovsky, Miriam; Kennedy, Chelsey; Sutovsky, Peter

    2012-01-01

    Inorganic pyrophosphate (PPi) is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1) in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF) rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS) and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies.

  8. Identification of the inorganic pyrophosphate metabolizing, ATP substituting pathway in mammalian spermatozoa.

    Directory of Open Access Journals (Sweden)

    Young-Joo Yi

    Full Text Available Inorganic pyrophosphate (PPi is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1 in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies.

  9. Isoprenoid Pyrophosphate-Dependent Transcriptional Regulation of Carotenogenesis in Corynebacterium glutamicum

    Directory of Open Access Journals (Sweden)

    Petra Peters-Wendisch

    2017-04-01

    Full Text Available Corynebacterium glutamicum is a natural producer of the C50 carotenoid decaprenoxanthin. The crtEcg0722crtBIYEb operon comprises most of its genes for terpenoid biosynthesis. The MarR-type regulator encoded upstream and in divergent orientation of the carotenoid biosynthesis operon has not yet been characterized. This regulator, named CrtR in this study, is encoded in many actinobacterial genomes co-occurring with terpenoid biosynthesis genes. CrtR was shown to repress the crt operon of C. glutamicum since DNA microarray experiments revealed that transcript levels of crt operon genes were increased 10 to 70-fold in its absence. Transcriptional fusions of a promoter-less gfp gene with the crt operon and crtR promoters confirmed that CrtR represses its own gene and the crt operon. Gel mobility shift assays with purified His-tagged CrtR showed that CrtR binds to a region overlapping with the −10 and −35 promoter sequences of the crt operon. Isoprenoid pyrophosphates interfered with binding of CrtR to its target DNA, a so far unknown mechanism for regulation of carotenogenesis. The molecular details of protein-ligand interactions remain to be studied. Decaprenoxanthin synthesis by C. glutamicum wild type was enhanced 10 to 30-fold upon deletion of crtR and was decreased 5 to 6-fold as result of crtR overexpression. Moreover, deletion of crtR was shown as metabolic engineering strategy to improve production of native and non-native carotenoids including lycopene, β-carotene, C.p. 450 and sarcinaxanthin.

  10. Feeling Abnormal: Simulation of Deviancy in Abnormal and Exceptionality Courses.

    Science.gov (United States)

    Fernald, Charles D.

    1980-01-01

    Describes activity in which student in abnormal psychology and psychology of exceptional children classes personally experience being judged abnormal. The experience allows the students to remember relevant research, become sensitized to the feelings of individuals classified as deviant, and use caution in classifying individuals as abnormal.…

  11. ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease

    International Nuclear Information System (INIS)

    Galli, M.; Marcassa, C.; Bosimini, E.; Zoccarato, O.; Comazzi, F.; Giannuzzi, P.

    1997-01-01

    To investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor ≥1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0.001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion. (orig./MG). With 5 figs., 4 tabs

  12. Development of Dy3+ activated K2MgP2O7 pyrophosphate phosphor for energy saving lamp

    International Nuclear Information System (INIS)

    Kohale, R.L.; Dhoble, S.J.

    2013-01-01

    Present work reports, synthesis of Dy 3+ activated K 2 MgP 2 O 7 pyrophosphate phosphor by using modified solid state diffusion that has been studied for its X-ray diffraction pattern (XRD). Furthermore, the chromaticity coordinate values were estimated from emission spectra of K 2 MgP 2 O 7 . The photoluminescence emission spectra of the phosphors having an excitation at around 351 nm (mercury free) showed two distinguishing bands centered at around 485 nm (blue) and 575 nm (yellow) corresponding to 4 F 9/2 → 6 H 15/2 and 4 F9 /2 → 6 H 13/2 transitions of Dy 3+ , respectively. These phosphors have strong absorption in the near UV region. K 2 MgP 2 O 7 pyrophosphate phosphor is suitable for color converter using UV light as the primary light source, which can be used as a blue/yellow phosphor excited by n-UV LED chip and mixed with other color emission phosphors to obtain white light. The 300–400 nm is Hg-free excitation (mercury excitation is 85% 254 nm wavelength of light and 15% other wavelengths), which is characteristic of solid-state lighting phosphors. Hence PL emission in trivalent dysprosium may be efficient photoluminescent materials for solid-state lighting phosphors. The intact study reveals that the present phosphor have promising applications in the lamp industry especially for solid state lighting (mercury-free excited lamp phosphor) and white light LED. -- Highlights: ► Dy 3+ activated pyrophosphate based phosphor prepared by modified solid state diffusion. ► PL emission spectrum of Dy 3+ ion under 351 nm excitation (Hg-free). ► PL emission at 485 nm (blue), 575 nm (yellow) emission. ► K 2 MgP 2 O 7 : Dy 3+ is expected to be a potential candidate for application in n-UV white LEDs and solid state lighting

  13. Redox Additive-Improved Electrochemically and Structurally Robust Binder-Free Nickel Pyrophosphate Nanorods as Superior Cathode for Hybrid Supercapacitors.

    Science.gov (United States)

    Sankar, Kalimuthu Vijaya; Seo, Youngho; Lee, Su Chan; Chan Jun, Seong

    2018-03-07

    For several decades, one of the great challenges for constructing a high-energy supercapacitor has been designing electrode materials with high performance. Herein, we report for the first time to our knowledge a novel hybrid supercapacitor composed of battery-type nickel pyrophosphate one-dimensional (1D) nanorods and capacitive-type N-doped reduced graphene oxide as the cathode and anode, respectively, in an aqueous redox-added electrolyte. More importantly, ex situ microscopic images of the nickel pyrophosphate 1D nanorods revealed that the presence of the battery-type redox additive enhanced the charge storage capacity and cycling life as a result of the microstructure stability. The nickel pyrophosphate 1D nanorods exhibited their maximum specific capacitance (8120 mF cm -2 at 5 mV s -1 ) and energy density (0.22 mWh cm -2 at a power density of 1.375 mW cm -2 ) in 1 M KOH + 75 mg K 3 [Fe(CN) 6 ] electrolyte. On the other side, the N-doped reduced graphene oxide delivered an excellent electrochemical performance, demonstrating that it was an appropriate anode. A hybrid supercapacitor showed a high specific capacitance (224 F g -1 at a current density of 1 A g -1 ) and high energy density (70 Wh kg -1 at a power density of 750 W kg -1 ), as well as a long cycle life (a Coulombic efficiency of 96% over 5000 cycles), which was a higher performance than most of those in recent reports. Our results suggested that the materials and redox additive in this novel design hold great promise for potential applications in a next-generation hybrid supercapacitor.

  14. Exercises to Improve Gait Abnormalities

    Science.gov (United States)

    ... Articles Directories Videos Resources Contact Exercises to Improve Gait Abnormalities Home » Article Categories » Exercise and Fitness Font Size: A A A A Exercises to Improve Gait Abnormalities Next Page The manner of how a ...

  15. Pregnancy Complications: Umbilical Cord Abnormalities

    Science.gov (United States)

    ... Umbilical cord abnormalities Umbilical cord abnormalities Now playing: E-mail to a friend Please fill in all fields. ... blood supply) to the baby. The two arteries transport waste from the baby to the placenta (where ...

  16. Molecular cloning and expression of Chimonanthus praecox farnesyl pyrophosphate synthase gene and its possible involvement in the biosynthesis of floral volatile sesquiterpenoids.

    Science.gov (United States)

    Xiang, Lin; Zhao, Kaige; Chen, Longqing

    2010-01-01

    Farnesyl pyrophosphate (FPP) synthase catalyzes the biosynthesis of FPP, which is the precursors of sesquiterpenoids such as floral scent volatiles, from isopentenyl pyrophosphate (IPP) and dimethylallyl pyrophosphate (DMAPP). cDNA encoding wintersweet (Chimonanthus praecox L.) FPP synthase was isolated by the RT-PCR and RACE methods. The deduced amino acid sequence showed a high identity to plant FPP synthases. Expression of the gene in Escherichia coli yielded FPPS activity that catalyzed the synthesis of FPP as a main product. Tissue-specific and developmental analyses of the mRNA levels of CpFPPS and volatile sesquiterpenoids levels in C. praecox flowers revealed that the FPPS may play a regulatory role in floral volatile sesquiterpenoids of wintersweet. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  17. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    International Nuclear Information System (INIS)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto; Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins; Brasileiro, Luis Porto

    2015-01-01

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  18. Molybdenum and technetium cycle in the environment. Physical chemical evolution and mobility in soils and plants

    International Nuclear Information System (INIS)

    Saas, A.; Denardi, J.L.; Colle, C.; Quinault, J.M.

    1980-01-01

    Molybdenum 99 and technetium 99 from liquid discharges of base nuclear installations (reactors, reprocessing plants, UF 6 treatment, etc.) can reach the environment via irrigation waters and atmospheric deposits. The contribution to the soil by irrigation results in a physical-chemical transformation, the results of which, in the case of technetium 99, could be volatilization via microbes. The changes in the physical-chemical forms of technetium in different soils reveals the preponderant effect of the initial amount deposited. The determination of the rate of technetium and molybdenum assimilation shows a certain similarity in behaviour; yet the localization of these isotopes is not the same. The transfer of molybdenum and technetium via the root system is different in its intensity; this is mainly due to different physical-chemical forms. Finally, each isotope has an optimum assimilation threshold and a toxicity threshold. The study of the physical-chemical evolution and the mobility in the soil-plant-water table system of these two isotopes shows a new aspect with respect to certain transfer channels to the human being [fr

  19. Reduction And Sequestration Of Pertechnetate To Technetium Dioxide And Protection From Reoxidation

    International Nuclear Information System (INIS)

    Duncan, J. B.; Johnson, J. M.; Moore, R. C.; Hagerty, K.; Rhodes, R. N.; Huber, H. J.; Moore, W. P.

    2012-01-01

    This effort is part of the technetium management initiative and provides data for the handling and disposition of technetium. To that end, the objective of this effort was to challenge tin(lI)apatite (Sn(II)apatite) against double-shell tank 241-AN-105 simulant spiked with pertechnetate (TcO 4 ). The Sn(II)apatite used in this effort was synthesized on site using a recipe developed at and provided by Sandia National Laboratories; the synthesis provides a high quality product while requiring minimal laboratory effort. The Sn(ll)apatite reduces pertechnetate from the mobile +7 oxidation state to the non-mobile +4 oxidation state. It also sequesters the technetium and does not allow for re-oxidization to the mobile +7 state under acidic or oxygenated conditions within the tested period of time (6 weeks). Previous work indicated that the Sn(II) apatite can achieve an ANSI leachability index in Cast Stone of 12.8. The technetium distribution coefficient for Sn(lI)apatite exhibited a direct correlation with the pH of the technetium-spiked simulant media

  20. The incorporation of technetium into a representative low-activity waste glass

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Bowers, D.L.; Buck, E.C.; Emery, J.W.

    1997-01-01

    A glass that has been tested to understand the corrosion behavior of waste glasses with high soda contents for immobilizing Hanford incidental wastes has been made by melting crushed glass with either TcO 2 or NaTcO 4 at 1,100--1,300 C. Incorporation of technetium in the glass was affected by solubility or kinetic effects. Metallic technetium inclusions formed in all the TcO 2 -doped glasses. Inclusions also formed in glasses with added NaTcO 4 that were melted at 1,100 C, but a glass melted at 1,200 C did not contain detectable inclusions. The presence of Tc-bearing inclusions complicates the interpretation of results from dissolution tests because of the simultaneous release of technetium from more than one phase, the unknown surface areas of each phase, and the possible incorporation of technetium that is released from one phase into another phase. A glass containing about 0.15 mass % Tc dissolved in the glass is being used in dissolution tests to study the release behavior of technetium

  1. Determination of a method to inhibit technetium migration at the repository

    International Nuclear Information System (INIS)

    Statler, V.; Tulenko, J.; Cloke, P.

    1990-01-01

    The long-term migration of 99 Tc (213,000-yr half-life) must be considered when examining the disposal of spent nuclear fuel in a geologic repository. This report outlines an investigation of the effects of iron, tin, stannous chloride, copper, manganese, and vanadium as reactants added to a mixture of technetium and J-13 well water to cause technetium precipitation. The J-13 well water was chosen because it is representative of the groundwater located at Yucca Mountain. A state-of-the-art computer software package, EQ3/6, was developed at Lawrence Livermore National Laboratory and was utilized in this study to project the result when metallic iron, tin, copper, manganese, and vanadium and the compound stannous chloride are individually added to a mixture of metallic technetium and J-13 well water. The computer codes in this study indicate that the problems associated with technetium migration at the federal repository are not insurmountable if a reactant capable of producing reducing conditions to the incoming groundwater is integrated into the waste package. Further work will focus on the laboratory experimentation to validate the computer results and to determine the best materials and configurations to inhibit technetium migration at the repository

  2. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  3. The peculiarities of electrochemical deposition and morphology of ZnMn alloy coatings obtained from pyrophosphate electrolyte

    Directory of Open Access Journals (Sweden)

    Bučko Mihael M.

    2011-01-01

    Full Text Available The first successful attempt to electrodeposit ZnMn alloy coatings from alkaline bath was made only a few years ago. In this kind of solution, potassium pyrophosphate (K4P2O7 serves both as a complexing agent and as the basic electrolyte. The aim of this work was to study the electrodeposition process and properties of ZnMn alloy coatings deposited from pyrophosphate solution, with a new kind of alkaline pyrophosphate bath. Namely, chloride salts were used as the source of metal ions and ascorbic acid was used as reducing agent. The composition of the plating solution was as follows: 1 mol dm-3 K4P2O7 + 0.017 mol dm-3 ascorbic acid + 0.05 mol dm-3 ZnCl2 + 0.05 mol dm-3 MnCl2•4H2O. Cathodic processes during the alloy electrodeposition were investigated using linear voltammetry. The influence of addition of small amounts of ascorbic acid on the cathodic processes was established. It was shown that this substance inhibits hydrogen evolution and increases the current efficiency of alloy deposition. The current efficiency in the plating bath examined was in the range of 25 and 30%, which was quite higher as compared to the results reported in the literature for electrodeposition of ZnMn alloy from pyrophosphate bath. Electrodeposition of ZnMn alloys was performed galvanostatically on steel panels, at current densities of 20120 mA cm-2. The coatings with the best appearance were obtained at current densities between 30 and 80 mA cm-2. The surface morphology studies, based on atomic force microscopy measurements, showed that morphology of the deposits is highly influenced by deposition current density. ZnMn coating deposited at 30 mA cm-2 was more compact and possessed more homogeneous structure (more uniform agglomeration size than the coating deposited at 80 mA cm-2. Such dependence of morphology on the current density could be explained by the high rate of hydrogen evolution reaction during the electrodeposition process.

  4. Sequential scintigraphy of the kidneys and joints with 99mTc-pyrophosphate in patients with rheumatic arthritis

    International Nuclear Information System (INIS)

    Askerov, N.M.; Dzhafarov, G.A.

    1990-01-01

    The proposed method of sequential scintigraphy of the kidneys and joints in a single administration of 99m Tc-pyrophosphate permits obtaining objective information on function and topography of the kidneys and pyodestructive processes in the joints. Dynamic scintigraphy helps to assess visually renal hemodynamics and the anatomotopographic position of the kidney and to obtain exhaustive information on accumulative-evacuatory function of each kidney individually. Scintigraphy also helps to investigate all the joints and to detect pyoinflammatory changes in them. The proposed method considerably reduces the time of investigation and lessens radiation exposure of patients, permitting repeated investigations to assess and correct the treatment of patients with rheumatic arthritis

  5. Experimental study of the radiation effects on the bone growth. Changes in Tc-99m pyrophosphate bone imaging

    International Nuclear Information System (INIS)

    Ohtake, H.; Sakai, Y.; Morita, S.; Kikuchi, S.; Bussaka, Y.; Oshibuchi, M.; Fukae, S.; Kaneyuki, Y.; Umezaki, N.

    1983-01-01

    Bones of immature rabbits during growth period were irradiated and followed up with bone scintigraphy with Tc-99m pyrophosphate. The accumulation ratio of radionuclide was decreased on the irradiated bone from an early period compared to the control side, and the decrease was more pronounced as the dose of irradiation increased. In groups irradiated with less than 4,000 rad, the ratio reached the minimum at 5 weeks, followed by a gradual recovery. These changes were evaluated with reference to the inhibition on longitudinal growth of the bone

  6. Kit for preparing a technetium-99m myocardial imaging agent

    International Nuclear Information System (INIS)

    Woulfe, S.R.; Deutsch, E.A.; Dyszlewski, M.; Neumann, W.L.

    1992-01-01

    This patent describes a kit for preparing a technetium 99m myocardial imaging agent. It comprises a first vial containing a lyophilized pyrogen free, sterile mixture of an effective reducing agent and a first ligand having the following general formula: wherein the R 1 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde and nitrile; the R 2 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde, and nitrile; the X and Y groups may be the same or different and are selected from the group consisting of oxygen and sulfur; and n is equal to 1 or 2; and a second vial containing a lyophilized pyrogen free, sterile protected salt of a phosphine ligand

  7. Absence of young white dwarf companions to five technetium stars

    Energy Technology Data Exchange (ETDEWEB)

    Smith, V.V.; Lambert, D.L.

    1987-10-01

    A search for hot companions to five stars of type MS and S has been carried out using the IUE satellite. No hot companions were detected for the MS stars HR 85, 4647, 6702, and 8062, and the S star HR 8714. Limits on the luminosities of possible white dwarf companions provide lower limits of 2-5x10 to the 8th yr to the ages of any degenerate companions. All five stars exhibit strong Tc I lines, and the presence of technetium, with a half-life of 2.1x10 to the 5th yr, signifies recent nucleosynthesis. The limits on the ages of possible white dwarf companions that are equal to or greater than 1000 half-lives of Tc exclude the possibility that the s-process elemental enhancement seen in these MS and S stars resulted from mass transfer from a more highly evolved companion (as is probably the mechanism by which barium stars are created). These MS and S stars represent a sample of true thermally pulsing asymptotic giant-branch stars. 41 references.

  8. Technetium Chemistry in HLW: Role of Organic Complexants

    International Nuclear Information System (INIS)

    Hess, Nancy J.; Blanchard, David L. Jr.; Campbell, James A.; Cho, Herman M.; Rai, Dhanpat Rai; Xia, Yuanxian; Conradson, Steven D.

    2002-01-01

    Technetium complexation with organic compounds in tank waste plays a significant role in the redox chemistry of Tc and the partitioning of Tc between the supernatant and sludge components in waste tanks. These processes need to be understood so that strategies to effectively remove Tc from high-level nuclear waste prior to waste immobilization can be developed and so that longterm consequences of Tc remaining in residual waste after sludge removal can be evaluated. Only limited data on the stability of Tc-organic complexes exists, and even less thermodynamic data on which to develop predictive models of Tc chemical behavior is available. To meet these challenges, we present a research program to study Tc-speciation in actual tank waste using state-of-the-art analytical organic chemistry, separations, and speciation techniques. On the basis of such studies, we will acquire thermodynamic data for the identified Tc-organic complexes over a wide range of chemical conditions in order to develop credible models to predict Tc speciation in tank waste and Tc behavior during waste pretreatment processing and in waste tank residuals

  9. Condensation mechanisms of tetravalent technetium in chloride media

    International Nuclear Information System (INIS)

    Poineau, F.

    2004-10-01

    In deep storage technetium can exist in degree IV or III. Recent studies on Tc(IV) have shown that Tc n O y (4n-2y)+ , Tc IV (μ-O) 2 Tc IV structure, is a precursor for precipitation of TcO 2 . Few data are available on Tc n O y (4n-2y)+ Subject of this thesis is the mechanism of condensation of Tc(IV) leading to this form. Kinetic studies have shown that the condensation of Tc IV Cl 5 (H 2 O) - in chloride media leads to a dimer. XAS studies resulted in a linear structure Tc IV -O-Tc IV . This compound, formulated as Tc 2 OCl 10 4- , is stable at pH = 0.3, it undergoes cyclization to Tc n O y (4n-2y)+ at pH =1.5 and is oxidized to TcO 4 - under α radiation. In 3 M chloride media, TcO 2 lead to formation Tc 2 OCl 10 4- at pH = 0.3 and to Tc n O y (4n-2y)+ at pH = 1.5. An electrochemical cell permitting 'in situ' XAS measurement was developed. XANES studies have shown that the reduction of Tc(VII) lead to a Tc(IV)/Tc(III) mixture. (author)

  10. Technetium behavior in sulfide and ferrous iron solutions

    International Nuclear Information System (INIS)

    Lee, S.Y.; Bondietti, E.A.

    1982-01-01

    Pertechnetate oxyanion ( 99 TcO 4- ), a potentially mobile species in leachate from a breached radioactive waste repository, was removed from a brine solution by precipitation with sulfide, iron, and ferrous sulfide at environmental pH's. Maghemite (ν-Fe 2 O 3 ) and geothite (α-FeOOH) were the dominant minerals in the precipitate obtained from the TcO 4- -ferrous iron reaction. The observation of small particle size and poor crystallinity of the minerals formed in the presence of Tc suggested that the Tc was incorporated into the mineral structure after reduction to a lower valence state. Amorphous ferrous sulfide, an initial phase precipitating in the TcO 4- -ferrous iron-sulfide reaction, was transformed to goethite and hematite (α-Fe 2 O 3 ) on aging. The black precipitate obtained from the TcO 4- -sulfide reaction was poorly crystallized technetium sulfide (Tc 2 S 7 ) which was insoluble in both acid and alkaline solution in the absence of strong oxidents. The results suggested that ferrous- and/or sulfide-bearing groundwaters and minerals in host rocks or backfill barriers could reduce the mobility of Tc through the formation of less-soluble Tc-bearing iron and/or sulfide minerals

  11. Biodistribution of 99m technetium labeled creatinine in healthy rats

    International Nuclear Information System (INIS)

    Yilmaz, O.; Soylu, A.; Kavukcu, S.; Lambrecht, F. Yurt; Durkan, K.

    2007-01-01

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with 99m technetium ( 99m Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 ± 2% under optimum conditions (pH 7 and 100 μg stannous chloride). Rats (N 12) were injected intravenously with 99m Tc creatinine and their blood and visceral organs were evaluated for 99m Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of 99m Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  12. Quality control of technetium-labelled lung imaging agents

    International Nuclear Information System (INIS)

    Chervu, L.R.; Vallabhajosula, S.R.; Blaufox, M.D.

    1977-01-01

    A study has been made of the labelling of macroaggregated albumin particles (MAA) with sup(99m)Tc using three commercial kits, and the results compared with those obtained with albumin microspheres. The tagging efficiency was measured by three different methods, and the chemistry and radiochemical nature of the sup(99m)Tc-MAA supernates or eluates were also investigated. The total body distribution of the sup(99m)Tc-MAA supernates was determined in mice after tail-vein injection. The results indicated that technetium-labelled MAA preparations may contain sup(99m)Tc-tagged albumin, similar to human serum albumin in solution. The nature of labelling pattern of MAA and the albumin microspheres indicated that the macroaggregates and microspheres were not completely or uniformly labelled during a one-step addition of pertechnetate. The lung aggregates had a large residual labelling capacity. Consideration is given to the significance of these results in lung perfusion studies. (U.K.)

  13. Absorption behavior of technetium and rhenium through plant roots

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2004-01-01

    The absorption behavior of technetium (Tc) and rhenium (Re) through plant roots was studied using nutrient solution culture. Radish samples, grown in culture solutions for 20-30 days in a green house, were transferred into plastic vessels containing nutrient solutions contaminated with multi-tracer solutions including Tc-95m and Re-183. The plant samples were grown individually for 1-7 days under laboratory conditions. The activities of radionuclides in nutrient solutions and oven-dried plant parts (roots, fleshy roots and leaves) were measured with Ge detecting systems. The concentrations of Tc-95m and Re-183 in the nutrient solutions after harvesting the plants were almost the same as those in the initial solution. Possibly, the radionuclides were taken up with water through plant roots. The distributions of Tc and Re in the plants showed no differences, thus, soluble Tc and Re absorption by plant samples were the same. It is suggested that Re could be used as a geochemical tracer of Tc in the soil environment. (author)

  14. Technetium labeling of dextran incorporating cysteamine as a ligand

    International Nuclear Information System (INIS)

    Matsunaga, Kazuhisa; Hara, Kazumichi; Imamura, Takeshi; Fujioka, Toshihiro; Takata, Jiro; Karube, Yoshiharu

    2005-01-01

    Introduction: Technetium-99m-labeled dextran is a useful imaging agent for procedures such as angiocardiography and lymphoscintigraphy. To improve the availability of 99m Tc-labeled dextran, we designed a cysteamine ligand system for dextran labeling. Methods: Cysteamine derivatized dextran was synthesized as follows. Dextran was oxidized with sodium periodate, coupled with cysteamine and reduced with sodium borohydride to provide the desired amine ligand. The cysteamine-dextran conjugate was then labeled with reduced 99m Tc. Whole-body scintigraphy and biodistribution were examined following injection of the 99m Tc-labeled cysteamine-conjugated dextran ( 99m Tc-cysteamine-dextran) in ICR mice. Lymphoscintigraphy was performed after intradermal injection of 99m Tc-cysteamine-dextran in SD rats. Results: The cysteamine-derived dextran was easily labeled with reduced 99m Tc in greater than 96% yield. 99m Tc-cysteamine-dextran has a higher chelation stability against diethylenetriamine pentaacetic acid (DTPA) than the 99m Tc-dextran. Axillary lymph nodes were clearly visible after intradermal injection of 99m Tc-cysteamine-dextran in rats. Conclusion: These results suggest that 99m Tc-cysteamine-dextran is available for lymphoscintigraphy. This methodology could expand the usage of 99m Tc-labeled dextran, particularly for diagnostic purposes

  15. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  16. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  17. Study on the behaviour of technetium-99 in soil environment

    International Nuclear Information System (INIS)

    Morita, S.; Katagiri, H.; Watanabe, H.; Akatsu, Y.; Ishiguro, H.

    1996-01-01

    Technetium-99 (Tc-99) is an important radionuclide for environmental assessment around nuclear fuel cycle facilities, because it has a long half-life and relatively high mobility in the environment. Its determination method, distribution and behaviour in the environment have been studied. While the method using an anti-coincidence type low background gas flow counter has been principally utilized as the conventional determination method for Tc-99, in recent years other determination methods such as neutron activation analysis and liquid scintillation counting method have also been considered. However, these methods are not effective to determine Tc-99 in environmental samples. because their detection limits are not low enough and measuring times are needed. Inductively Coupled Plasma Mass Spectrometer (ICP-MS) is a quantitative and qualitative analysis apparatus having superior characteristics such as extremely low detection limit, high resolution, high precision short measurement time and capability for simultaneous multi-elements analysis. This study developed an analysis technique to acquire field data. As the results, several information regarding the distribution and behaviour of Tc-99 in the surface soil environment was obtained. (author)

  18. Technetium-99m DTPA renal flow studies in Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nally, J.V.; Clarke, H.S.; Windham, J.P.; Grecos, G.P.; Gross, M.L.; Potvin, W.J.

    1985-01-01

    Computer-assisted dynamic renal studies were performed on a group of 14 mongrel dogs before and after the induction of unilateral renal artery stenosis. Ninety-second technetium-99m diethylenetriaminepentaacetic acid ([/sup 99m/Tc]DTPA), 15-min [/sup 99m/Tc]DTPA, and 30-min iodine-131 orthoiodohippurate ([ 131 I]hippuran) time-activity curves were analyzed and correlated with reduction of renal blood flow as measured by electromagnetic flow probe and PAH clearance techniques. For blood flow reductions greater than 33%, the [/sup 99m/Tc]DTPA studies were judged diagnostic of unilateral renal artery stenosis in all cases, whereas the [ 131 I]hippuran time-activity curves were indicative of stenosis in only six of ten studies. Thus, in this model we find the computer-assisted 90-sec [/sup 99m/Tc]DTPA renal flow study to be superior to conventional [ 131 I]hippuran renography in the diagnosis of moderate-to-serve unilateral renal artery stenosis

  19. Characterization of electrochemically and chemically generated technetium diphosphonate radiopharmaceuticals

    International Nuclear Information System (INIS)

    Martin, J.L. Jr.

    1987-01-01

    Tc-Methylene diphosphonate, (MDP), the skeletal imaging ligand is most use in radiopharmacies, is the first metal-ligand complex prepared electrochemically in this work. A similar systematic evaluation of electrochemically reduced Tc-dimethylaminomethylene diphosphonate (DMAD) is presented. DMAD as well as MDP have been characterized by anion exchange HPLC following NaBH4 reduction. The goal is twofold. First, the effect of varying the applied potential on the resultant chromatographic distribution of complexes is investigated. Secondly, the combination(s) of applied potential and preparation pH which preferentially directs the formation of technetium diphosphonate complexes previously shown to be superior skeletal imaging agents is determined. EXAFS, extended x-ray absorption fine structure spectroscopy, is applied to the analysis of dilute solutions (10mM) of electrochemically and chemically reduced Tc-MDP complexes. Further characterizations of electrochemically and chemically generated complexes are performed using in-vitro and in-vivo physiological techniques of biodistribution and blood clearance studies on Sprague Dawley rats and beagle dogs respectively. Finally, in-vitro and in-vivo dilution studies were performed using water, human and dog urine, to determine the influence of the physiological environment on clinically prepared and injected radiopharmaceuticals

  20. Technetium Inventory, Distribution, and Speciation in Hanford Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pegg, Ian L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-11-13

    The purpose of this report is three fold: 1) assemble the available information regarding Tc inventory, distribution between phases, and speciation in Hanford’s 177 storage tanks into a single, detailed, comprehensive assessment; 2) discuss the fate (distribution/speciation) of Tc once retrieved from the storage tanks and processed into final waste forms; and 3) discuss/document in less detail the available data on the inventory of Tc in other “pools” such as the vadose zone below inactive cribs and trenches, below single-shell tanks (SSTs) that have leaked, and in the groundwater below the Hanford Site. This report was revised in September 2014 to add detail and correct inaccuracies in Section 5.0 on the fate of technetium (Tc) recycle from the off-gas systems downstream of the low-activity waste (LAW) melters back to the melters, based on several reports that were not found in the original literature search on the topic. The newly provided reports, from experts active in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) glass studies, the Vitreous State Laboratory at The Catholic University of America (VSL) melter and off-gas system demonstrations and overall WTP systems analysis, were not originally found on electronic databases commonly searched. The major revisions to Section 5.0 also required changes to Section 7.0 (Summary and Conclusions) and this executive summary.

  1. An introduction to technetium in the gaseous diffusion cascades

    International Nuclear Information System (INIS)

    Simmons, D.W.

    1996-09-01

    The radioisotope technetium-99 ( 99 Tc) was introduced into the gaseous diffusion plants (GDP) as a contaminant in uranium that had been reprocessed from spent nuclear reactor fuel. 99 Tc is a product of the nuclear fission of uranium-235 ( 235 U). The significantly higher emitted radioactivity of 99 Tc generates concern in the enrichment complex and warrants increased attention (1) to the control of all site emissions, (2) to worker exposures and contamination control when process equipment requires disassembly and decontamination, and (3) to product purity when the enriched uranium hexafluoride (UF 6 ) product is marketed to the private sector. A total of 101,268 metric tons of RU (∼96% of the total) was fed at the Paducah Gaseous Diffusion Plant (PGDP) between FY1953 and FY1976. An additional 5600 metric tons of RU from the government reactors were fed at the Oak Ridge Gaseous Diffusion Plant (ORGDP), plus an approximate 500 tons of foreign reactor returns. Only a small amount of RU was fed directly at the Portsmouth Gaseous Diffusion Plant (PORTS). The slightly enriched PGDP product was then fed to either the ORGDP or PORTS cascades for final enrichment. Bailey estimated in 1988 that of the 606 kg of Tc received at PGDP from RU, 121 kg was subsequently re-fed to ORGDP and 85 kg re-fed to PORTS

  2. Technetium-99m in nuclear medicine and radiation protection experience

    International Nuclear Information System (INIS)

    Ninkovic, M. M.; Raicevic, J. J.; Pavlovic, S.; Glisic, R.

    2002-01-01

    The one of the major contributors to personnel exposure whithin nuclear medicine laboratories is primarily now ubiquitous 99 Mo- 99m Tc generators. These generators, first available about more than forthy years ago, are now providing large quantities of 99m Tc radioactive source daily in the most laboratories, both for direct injection, as a per-technetate ion, and through the utilization of the kits for the preparation of dipherent radiopharmaceuticals. The safe and efficient utilization of technetium-99m in nuclear medicine, as other radionuclides, begin with the design, construction and operation of the 'Hot'Laboratory area, where radionuclide are stored and patient doses are prepared. Regardless of the specific physical configuration, suitable facilities need to be provided and good working practices established in order to get these principal objectives: (a) keep radiation exposure to personnel at ALARA levels; (b) prevent contamination of personnel; (c) prevent contamination of measuring instruments (including imaging devices such as gamma cameras and rectilinear scanners), and (d) prevent spread of contamination to places or persons outside the laboratory

  3. Technetium-99m sestamibi: an indicator of breast cancer invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Schillaci, O. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Scarpini, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Mingazzini, P.L. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Di Macio, L. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Banci, M. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Danieli, R. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Zerilli, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Limiti, M.R. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Centi Colella, A. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy))

    1994-09-01

    As recently shown, angiogenesis is the most reliable marker of breast cancer invasiveness. Unfortunately it must be assessed by immunohistochemistry on tissue specimens. We have used technetium-99m sestamibi, a marker of regional blood flow in other organs that often but not always images breast cancer, to assess the invasiveness of this tumour. Nineteen patients, ten with nodal metastases and nine without any metastases, were studied with [sup 99m]Tc-sestamibi scintigraphy before operation. Angiogenesis was quantitatively assessed by immunohistochemical staining of endothelia for factor VIII. All the node-positive (N+) patients at surgical revesion showed a positive [sup 99m]Tc-sestamibi scan of the primary tumour and all the N-patients were negative. Nine out of ten N+ and sestamibi-positive tumours showed more than 135 microvessels/mm[sup 2] and one showed 99 microvessels/mm[sup 2]; by contrast there were 71.6[+-]12.1 microvessels/mm[sup 2] in the nine N- and sestamibi-negative tumours. Our study suggests that [sup 99m]Tc-sestamibi is a marker of breast cancer invasiveness: its uptake is related to angiogenesis and, possibly, to oxidative metabolism of the tumour. (orig.)

  4. Normal and abnormal growth plate

    International Nuclear Information System (INIS)

    Kumar, R.; Madewell, J.E.; Swischuk, L.E.

    1987-01-01

    Skeletal growth is a dynamic process. A knowledge of the structure and function of the normal growth plate is essential in order to understand the pathophysiology of abnormal skeletal growth in various diseases. In this well-illustrated article, the authors provide a radiographic classification of abnormal growth plates and discuss mechanisms that lead to growth plate abnormalities

  5. [Penile congenital abnormalities].

    Science.gov (United States)

    Boillot, B; Teklali, Y; Moog, R; Droupy, S

    2013-07-01

    Congenital abnormalities of the penis are usually diagnosed at birth and pose aesthetic and functional problems sometimes requiring surgical management. A literature review was conducted on Medline considering the articles listed until January 2012. Hypospadias is the most common malformation (1 in 250 boys. Familial forms: 7%). The causes remain hypothetical but the doubling of the incidence in 30 years could be linked to fetal exposure to endocrine disruptors "estrogen-like" used in the food industry in particular. Surgical treatment is usually intended to improve the aesthetic appearance but sometimes, in case of significant curvature or posterior meatus, necessary for normal sexual life and fertility. Other malformations (epispades, buried penis, transpositions, twists and preputial abnormalities) as well as management for functional or aesthetic consequences of these malformations in adulthood require complex surgical care in a specialized environment. The improvement of surgical techniques and pediatric anesthesia allows an early and effective specialized surgical approach of penile malformations. Management of sequelae in adulthood must be discussed and requires experience of surgical techniques on pediatric and adult penis. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Role of technetium-99m sestamibi scintimammography and contrast-enhanced magnetic resonance imaging for the evaluation of indeterminate mammograms

    International Nuclear Information System (INIS)

    Tiling, R.; Moser, R.; Meyer, G.; Tatsch, K.; Hahn, K.; Khalkhali, I.; Sommer, H.; Willemsen, F.; Pfluger, T.

    1997-01-01

    This study evaluated and compared technetium-99m sestamibi scintimammography (SMM) and breast magnetic resonance imaging (MRI) results in patients with indeterminate mammograms to determine whether either technique can improve the sensitivity and specificity for the diagnosis of breast carcinoma. From 123 consecutive patients who underwent physical examination, mammography, SMM, and histopathologic confirmation, a subgroup of 82 patients presenting with indeterminate mammograms was studied. Sixty-eight patients underwent contrast-enhanced MRI. SMM results were scored on the basis of the intensity and pattern of sestamibi uptake. MRI images were scored on the basis of signal intensity increase after administration of contrast material as well as the enhancement pattern and speed of gadolinium uptake. The results obtained with the two techniques were compared and related to the final histopathologic diagnoses. Considering indeterminate findings as positive, the sensitivity of SMM was 79% and the specificity, 70%. MRI displayed a sensitivity of 84% and a specificity of 49%. When indeterminate results were considered negative, the sensitivity and specificity of SMM were 62% and 83%, respectively. MRI revealed a sensitivity and specificity of 56% and 79%, respectively. The calculated sensitivities and specificities demonstrate the diagnostic limitations of both SMM and MRI in the evaluation of patients with indeterminate mammographic findings. Due to the higher specificity, SMM may be the preferred modality in the evaluation of selected patients with breast abnormalities. (orig.)

  7. Evaluation of dysthymic disorder with technetium-99 m hexamethylpropylene amine oxime brain single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sarikaya, A.; Cermik, T.F. [Department of Nuclear Medicine, Trakya University, Faculty of Medicine, Edirne (Turkey); Karasin, E.; Abay, E. [Department of Psychiatry, Trakya University, Faculty of Medicine, Edirne (Turkey); Berkarda, S.

    1999-03-01

    Dysthymic disorder is a chronic disorder characterised by the presence of a depressed mood and is classified as a distinct category in DSM-IV, separately from major depression. Although brain imaging studies have been performed in major depressive disease, there have to date been no reports of such studies in dysthymic disorder. In this study 36 patients with dysthymic disorder were compared with 16 normal subjects using technetium-99m hexamethylpropylene amine oxime brain single-photon emission tomography. A relative blood flow ratio was calculated for each region of interest using the average tissue activity in the region divided by activity in the cerebellum. There were significant differences in the bilateral inferior frontal, bilateral parietal, right superior frontal and left posterior temporal regions in the patients with dysthymic disorder compared with the healthy controls. These findings support the hypothesis that the biological bases for dysthymic disorder and major depression are similar. Recognition of these regional abnormalities may have clinical utility in both the diagnosis and the treatment of dysthymic disorder. Further studies are needed to confirm our results and to assess the influence of treatment in patients with dysthymic disorder. (orig.) With 1 fig., 1 tab., 26 refs.

  8. Evaluation of dysthymic disorder with technetium-99 m hexamethylpropylene amine oxime brain single-photon emission tomography

    International Nuclear Information System (INIS)

    Sarikaya, A.; Cermik, T.F.; Karasin, E.; Abay, E.; Berkarda, S.

    1999-01-01

    Dysthymic disorder is a chronic disorder characterised by the presence of a depressed mood and is classified as a distinct category in DSM-IV, separately from major depression. Although brain imaging studies have been performed in major depressive disease, there have to date been no reports of such studies in dysthymic disorder. In this study 36 patients with dysthymic disorder were compared with 16 normal subjects using technetium-99m hexamethylpropylene amine oxime brain single-photon emission tomography. A relative blood flow ratio was calculated for each region of interest using the average tissue activity in the region divided by activity in the cerebellum. There were significant differences in the bilateral inferior frontal, bilateral parietal, right superior frontal and left posterior temporal regions in the patients with dysthymic disorder compared with the healthy controls. These findings support the hypothesis that the biological bases for dysthymic disorder and major depression are similar. Recognition of these regional abnormalities may have clinical utility in both the diagnosis and the treatment of dysthymic disorder. Further studies are needed to confirm our results and to assess the influence of treatment in patients with dysthymic disorder. (orig.)

  9. Roentgenologic abnormalities in Down's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Takehiko; Russell, W J; Komatsuda, Michio; Neriishi, Shotaro

    1968-07-25

    Roentgenograms of 28 patients with Down's syndrome were reviewed with emphasis on all previously reported abnormalities and any possible additional ones. Most of the abnormalities occurred with the same frequency as previously reported, but some less frequently reported findings were also seen. One abnormal vertebral measurement found in this series may be an additional stigma of Down's syndrome. All of the 27 cases studied cytogenetically had chromosomal abnormalities consistent with this disease. This study emphasizes the need for roentgenologic norms for the Japanese, and the desirability of combining chromosome studies with roentgenological abnormalities and clinical observations in diagnosing Down's syndrome. 19 references, 2 figures, 5 tables.

  10. Transmutation of technetium into stable ruthenium in high flux conceptual research reactor

    International Nuclear Information System (INIS)

    Amrani, N.; Boucenna, A.

    2007-01-01

    The effectiveness of transmutation for the long lived fission product technetium-99 in high flux research reactor, considering its large capture cross section in thermal and epithermal region is evaluated. The calculation of Ruthenium concentration evolution under irradiation was performed using Chain Solver 2.20 code. The approximation used for the transmutation calculation is the assumption that the influence of change in irradiated materials structures on the reactor operator mode characteristics is insignificant. The results on Technetium transmutation in high flux research reactor suggested an effective use of this kind of research reactors. The evaluation brings a new concept of multi-recycle Technetium transmutation using HFR T RAN (High Flux Research Reactor for Transmutation)

  11. Performance testing of blast furnace slag for immobilization of technetium in grout

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Spence, R.D.; Evans-Brown, B.S.; Morgan, I.L.; Shoemaker, J.L.; Bostick, W.D.

    1988-01-01

    This paper presents preliminary results of a grout development effort to identify grout formulas that can satisfactorily sequester 99 Tc contained in an existing Portsmouth Gaseous Diffusion Plant waste. Technetium is of particular concern to the US Nuclear Regulatory Commission (NRC) because of its mobility and biological activity. The mobility of technetium results in large part from the movement of the pertechnate anion [prevalent in low-level radioactive waste (LLW)] through soil and geologic strata with little or no interaction with the surrounding matrix. Ground blast furnace slag has been shown to improve the leach resistance of cement-based waste forms, particularly in regard to technetium. This improved performance has been attributed to fewer and smaller pores in the solidified slags (versus a neat cement paste) and to the reduction of the pertechnate ion to a less soluble form. 9 refs., 2 tabs

  12. Diffusion of 99-technetium in bentonite under aerobic and anaerobic conditions

    International Nuclear Information System (INIS)

    Vecernik, P.; Jedinakova-Krizova, V.; Vokal, A.

    2006-01-01

    Diffusion experiments were performed with 99 Tc and Re (a model of technetium) in the form of pertechnetate and perrhenate in bentonite from the Rokle locality (Czech Republic). The through diffusion method was used, and the apparent diffusion coefficients (D a ) were evaluated. The effects of the particle mesh-size, bulk densities, and aerobic or anaerobic conditions on the diffusion were studied in view of the fact that oxidizing or reducing conditions influence the chemical forms of technetium and rhenium. In the presence of oxygen, technetium and rhenium occur in oxidation state VII, as anions which are soluble and mobile in the environment, whereas in reducing conditions they occur in lower oxidation states, mainly as insoluble oxides or hydroxides. Aerobic experiments were carried out in common laboratory conditions, anaerobic experiments were performed under nitrogen

  13. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  14. Technetium electrochemistry. 7. Electrochemical and spectroelectrochemical studies on technetium(III) and -(II) complexes containing polypyridyl ligands

    International Nuclear Information System (INIS)

    Wilcox, B.E.; Deutsch, E.

    1991-01-01

    The redox properties of a series of technetium(III/II) complexes of the general formula cis(X), trans(P)-[Tc III/II X 2 (PR w R') 2 L] 10+ , where X = Cl or Br, PR 2 R' = dimethylphenylphosphine or ethyldiphenylphosphine, and L = 2,2'-bipyridine (bpy), 4,4'-dimethyl-2,2'-bipyridine (Me 2 bpy), or 1,10-phenanthroline (phen), were investigated in 0.1 M TEAP/acetonitrile by cyclic voltammetry at a platinum-disk electrode. These complexes exhibit diffusion-controlled, 1-equiv Tc(IV)/Tc(III) redox couples and also Tc(III)/Tc(II) redox couples. Spectropotentiostatic experiments on three complexes of this class in 0.5 M TEAP/DMF confirm the 1-equiv character of the Tc(III)/Tc(II) couple. The electrochemical behavior of Tc(II) complexes of the general formula trans(P)-[TcX(PR 2 R') 2 terpy] + , terpy = 2,2':6',2 double-prime-terpyridine, was also investigated under the same conditions as above. These complexes exhibit diffusion-controlled, 1-equiv Tc(III)/Tc(II) redox couples and Tc(II)/Tc(I) redox couples. Spectropotentiostatic experiments on trans(P)-[TcCl(PMe 2 Ph) 2 terpy] + confirm the 1-equiv character of the Tc(III)/Tc(II) couple but show that the Tc(II)/Tc(I) couple is not reversible on the spectropotentiostatic time scale

  15. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    Energy Technology Data Exchange (ETDEWEB)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables.

  16. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    International Nuclear Information System (INIS)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables

  17. Fundamental chemistry, characterization, and separation of technetium complexes in Hanford waste. 1998 annual progress report

    International Nuclear Information System (INIS)

    Ashley, K.R.; Blanchard, D.L. Jr.; Schroeder, N.C.

    1998-01-01

    'The ultimate goal of this proposal is to separate technetium from Hanford tank waste. The recent work has shown that a large portion of the technetium is not pertechnetate (TcO 4 - ) and is not easily oxidized. This has serious repercussions for technetium partitioning schemes because they are designed to separate this chemical form. Rational attempts to oxidize these species to TcO 4 - for processing or to separate the non-pertechnetate species themselves would be facilitated by knowing the identity of these complexes and understanding their fundamental chemistry. Tank characterization work has not yet identified any of the non-pertechnetate species. However, based on the types of ligands available and the redox conditions in the tank, a reasonable speculation can be made about the types of species that may be present. Thus, this proposal will synthesize and characterize the relevant model complexes of Tc(III), Tc(IV), and Tc(V) that may have formed under tank waste conditions. Once synthesized, these complexes will be used as standards for developing and characterizing the non-pertechnetate species in actual waste using instrumental techniques such as capillary electrophoresis electrospray mass spectrometry (CE-MS), x-ray absorbance spectroscopy (EXAFS and XANES), and multi-nuclear NMR (including 99 Tc NMR). The authors study the redox chemistry of the technetium complexes so that more efficient and selective oxidative methods can be used to bring these species to TcO 4 - for processing purposes. They will also study their ligand substitution chemistry which could be used to develop separation methods for non-pertechnetate species. Understanding the fundamental chemistry of these technetium complexes will enable technetium to be efficiently removed from the Hanford tank waste and help DOE to fulfill its remediation mission. This report summarizes the first 8 months of a 3-year project.'

  18. Separation, Concentration, and Immobilization of Technetium and Iodine from Alkaline Supernate Waste

    Energy Technology Data Exchange (ETDEWEB)

    James Harvey; Michael Gula

    1998-12-07

    Development of remediation technologies for the characterization, retrieval, treatment, concentration, and final disposal of radioactive and chemical tank waste stored within the Department of Energy (DOE) complex represents an enormous scientific and technological challenge. A combined total of over 90 million gallons of high-level waste (HLW) and low-level waste (LLW) are stored in 335 underground storage tanks at four different DOE sites. Roughly 98% of this waste is highly alkaline in nature and contains high concentrations of nitrate and nitrite salts along with lesser concentrations of other salts. The primary waste forms are sludge, saltcake, and liquid supernatant with the bulk of the radioactivity contained in the sludge, making it the largest source of HLW. The saltcake (liquid waste with most of the water removed) and liquid supernatant consist mainly of sodium nitrate and sodium hydroxide salts. The main radioactive constituent in the alkaline supernatant is cesium-137, but strontium-90, technetium-99, and transuranic nuclides are also present in varying concentrations. Reduction of the radioactivity below Nuclear Regulatory Commission (NRC) limits would allow the bulk of the waste to be disposed of as LLW. Because of the long half-life of technetium-99 (2.1 x 10 5 y) and the mobility of the pertechnetate ion (TcO 4 - ) in the environment, it is expected that technetium will have to be removed from the Hanford wastes prior to disposal as LLW. Also, for some of the wastes, some level of technetium removal will be required to meet LLW criteria for radioactive content. Therefore, DOE has identified a need to develop technologies for the separation and concentration of technetium-99 from LLW streams. Eichrom has responded to this DOE-identified need by demonstrating a complete flowsheet for the separation, concentration, and immobilization of technetium (and iodine) from alkaline supernatant waste.

  19. Ictal Cardiac Ryhthym Abnormalities.

    Science.gov (United States)

    Ali, Rushna

    2016-01-01

    Cardiac rhythm abnormalities in the context of epilepsy are a well-known phenomenon. However, they are under-recognized and often missed. The pathophysiology of these events is unclear. Bradycardia and asystole are preceded by seizure onset suggesting ictal propagation into the cortex impacting cardiac autonomic function, and the insula and amygdala being possible culprits. Sudden unexpected death in epilepsy (SUDEP) refers to the unanticipated death of a patient with epilepsy not related to status epilepticus, trauma, drowning, or suicide. Frequent refractory generalized tonic-clonic seizures, anti-epileptic polytherapy, and prolonged duration of epilepsy are some of the commonly identified risk factors for SUDEP. However, the most consistent risk factor out of these is an increased frequency of generalized tonic-clonic seizures (GTC). Prevention of SUDEP is extremely important in patients with chronic, generalized epilepsy. Since increased frequency of GTCS is the most consistently reported risk factor for SUDEP, effective seizure control is the most important preventive strategy.

  20. A Rare Stapes Abnormality

    Directory of Open Access Journals (Sweden)

    Hala Kanona

    2015-01-01

    Full Text Available The aim of this study is to increase awareness of rare presentations, diagnostic difficulties alongside management of conductive hearing loss and ossicular abnormalities. We report the case of a 13-year-old female reporting progressive left-sided hearing loss and high resolution computed tomography was initially reported as normal. Exploratory tympanotomy revealed an absent stapedius tendon and lack of connection between the stapes superstructure and footplate. The footplate was fixed. Stapedotomy and stapes prosthesis insertion resulted in closure of the air-bone gap by 50 dB. A review of world literature was performed using MedLine. Middle ear ossicular discontinuity can result in significant conductive hearing loss. This can be managed effectively with surgery to help restore hearing. However, some patients may not be suitable or decline surgical intervention and can be managed safely conservatively.