WorldWideScience

Sample records for abnormal pulsatility index

  1. Imaging findings of pulsatile tinnitus caused by sigmoid sinus abnormalities

    International Nuclear Information System (INIS)

    Liang Xihong; Wang Zhenchang; Gong Shusheng; Xia Yin; Wang Zhengyu; Yang Bentao; Yan Fei; Li Jing; Xian Junfang; Chen Guangli

    2010-01-01

    Objective: To study a rare CT finding of pulsatile tinnitus (PT) caused by sigmoid sinus abnormalities. Methods: The imaging data of PT caused by sigmoid sinus abnormalities were analyzed retrospectively in 15 patients (15 female). The median age was 45 years (24 to 63 years). The duration of persistence pulsatile tinnitus was from 0.5 year to 36.0 years (median time, 2.0 years). The tinnitus was at left side in 5 patients and right side in 10 patients. Fifteen patients underwent HRCT of the temporal bone. Of them, 12 patients underwent cerebral CT angiography and CT venogram (CTA/CTV), and 9 patients underwent cerebral digital subtraction angiography (DSA). Nine patients underwent transmastoid reconstruction surgery of the sigmoid sinus. Of them, the tinnitus was at left side in 2 patients and right side in 7 patients. Paired rank sum test was used to compare the cross-sectional area of the sigmoid sinus of the tinnitus side and normal side.Results: On HRCT, foca bony coarse defect is shown in the anterior sigmoid wall in 11 patients and anterolateral sigmoid wall in 4 patients. On CTA/CTV, the sigmoid sinus focally protuded into the adjacent mastoid air cells and formed diverticulum in 10 patients. The pulsatile tinnitus disappeared immediately after transmastoid reconstruction surgery of the sigmoid sinus in all 9 patients. The cross-sectional area of the sigmoid sinus of the tinnitus side was 100.6 (41.5-96.2)mm 2 , it was 77.0 (92.1-122.4)mm 2 in the nonmal side (Z=2.158, P=0.031). Conclusion: Focal bony defect of the sigmoid wall with sigmoid sinus diverticula is one of the causes which lead to pulsatile tinnitus, which can be easily identified by imaging examination. (authors)

  2. Renal artery pulsatility index and renal volume: Normal fetuses versus growth-retarded fetuses

    International Nuclear Information System (INIS)

    Lee, Kyung Soon; Woo, Bock Hi

    2001-01-01

    To evaluate the blood flow velocity waveform of the renal artery and renal volume of growth-retarded fetuses and to compare them with those of normal fetuses. Pulsatility index of the renal artery and renal volume measured by three-dimensional ultrasonography were obtained from seventy eight normal fetuses at the gestational age from twenty five to thirty nine weeks and eighteen intrauterine growth retarded fetuses whose weight was below ten percentile at birth. We studied changes of the pulsatility index of the renal artery and renal volume according to the gestational age and compared with those of growth-retarded fetuses. Pulsatility index (PI) of the fetal renal artery decreased throughout the gestational period (r=0.703, p<0.0001). In growth-retarded fetuses, despite of abnormal doppler velocity waveform of the middle cerebral artery, which was showing fetal hypoxia, the renal PI was not increased significantly. The fetal renal volume increased throughout the gestational period (r=0.834, p<0.0001) whereas in growth-retarded fetuses, all renal volume was below fifth percentile of normal fetuses. In growth-retarded fetuses, fetal renal volume was decreased significantly without change of the renal vascular flow. Therefore, the fetal renal volume measured by three-dimensional ultrasonography may be a helpful parameter in the diagnosis of growth-retarded fetuses.

  3. Increased uterine artery pulsatility index at 34 weeks and outcome of pregnancy.

    Science.gov (United States)

    Maroni, E; Youssef, A; Arcangeli, T; Nanni, M; De Musso, F; Contro, E; Kuleva, M; Bellussi, F; Pilu, G; Rizzo, N; Ghi, T

    2011-10-01

    To evaluate pregnancy outcome in patients with increased uterine artery (UtA) pulsatility at 34 weeks' gestation as an isolated finding. Normotensive women attending at 34 weeks' gestation for fetal growth assessment were enrolled in the study if fetal growth was appropriate for age and mean UtA pulsatility index (PI) was persistently above the 95(th) centile for gestational age. Patients were excluded with any of the following conditions: multiple pregnancy, sonographic suspicion of fetal anomaly or fetal growth restriction, history of chronic maternal disease, hypertensive disorder or diabetes in the current pregnancy or one or more adverse events in their past obstetric history. The control group consisted of age- and body mass index-matched low-risk women attending at 34 weeks with normal uterine artery Doppler since the midtrimester. Sixty-six normotensive patients with normal fetal growth and increased UtA-PI at 34 weeks were included in the study group. Women with abnormal Doppler findings compared with controls showed significantly lower gestational age at delivery (38.2 ± 1.6 vs. 38.9 ± 1.3 weeks, P = 0.006), birth weight (2942 ± 583 vs. 3404 ± 469 g, P UtA-PI as an isolated finding at 34 weeks' gestation is associated with an increased risk of delivering an SGA neonate. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  4. Uterine artery pulsatility index in hypertensive pregnancies: When does the index normalize in the puerperium?

    OpenAIRE

    Lee, Seung Mi; Jun, Jong Kwan; Sung, Su Jin; Choo, Sung Il; Cho, Jeong Yeon; Yang, Hye Jin; Park, Chan-Wook; Park, Joong Shin; Syn, Hee Chul

    2016-01-01

    Objective To investigate whether the uterine artery pulsatility index (UtA PI) of hypertensive pregnancies is higher than that of normal pregnancies in the puerperium, as well as in the antepartum period. Methods The UtA PI was measured in hypertensive (group 1) and normal pregnancies (group 2) during antepartum, immediate postpartum or late postpartum periods. Using the transvaginal approach, the bilateral uterine artery indices were measured. Results One hundred twenty-two women were enroll...

  5. High-flavanol and high-theobromine versus low-flavanol and low-theobromine chocolate to improve uterine artery pulsatility index: a double blind randomized clinical trial

    OpenAIRE

    Bujold, Emmanuel; Leblanc, Vicky; Lavoie-Lebel, Élise; Babar, Asma; Girard, Mario; Poungui, Lionel; Blanchet, Claudine; Marc, Isabelle; Lemieux, Simone; Abdous, Belkacem; Anassour-Laouan-Sidi, Elhadji; Dodin-Dewailly, Sylvie

    2016-01-01

    Objective: To evaluate the impact of high-flavanol and high-theobromine (HFHT) chocolate in women at risk of preeclampsia (PE). Study design: We conducted a single-center randomized controlled trial including women with singleton pregnancy between 11 and 14 weeks gestation who had bilateral abnormal uterine artery (UtA) waveforms (notching) and elevated pulsatility index (PI). Participants were randomized to either HFHT or low-flavanol and low-theobromine (LFLT) chocolate (30 g...

  6. Uterine artery pulsatility index in hypertensive pregnancies: When does the index normalize in the puerperium?

    Science.gov (United States)

    Lee, Seung Mi; Jun, Jong Kwan; Sung, Su Jin; Choo, Sung Il; Cho, Jeong Yeon; Yang, Hye Jin; Park, Chan-Wook; Park, Joong Shin; Syn, Hee Chul

    2016-11-01

    To investigate whether the uterine artery pulsatility index (UtA PI) of hypertensive pregnancies is higher than that of normal pregnancies in the puerperium, as well as in the antepartum period. The UtA PI was measured in hypertensive (group 1) and normal pregnancies (group 2) during antepartum, immediate postpartum or late postpartum periods. Using the transvaginal approach, the bilateral uterine artery indices were measured. One hundred twenty-two women were enrolled: group 1, hypertensive disease in pregnancy (11 cases in antepartum, 13 cases in immediate postpartum and 10 cases in late postpartum period); group 2, normal pregnancies (32 cases in antepartum, 29 cases in immediate postpartum and 27 cases in late postpartum). In antepartum and immediate postpartum periods, the mean UtA PI and the proportion of cases with an early diastolic notch were higher in group 1 than in group 2 (antepartum mean UtA PI, 1.14 in group 1 vs. 0.68 in group 2, P UtA PI, 1.30 vs. 1.08, P UtA PI of group 1 was still higher than that of group 2, although the proportion of cases with an early diastolic notch was not different (mean UtA PI, 1.43 vs. 1.20, P UtA PI in hypertensive pregnancies was still higher than normal pregnancies in puerperal periods, suggesting that more than several weeks are required to resolve increased uterine artery vascular impedance.

  7. The pulsatility index and the resistive index in renal arteries. Associations with long-term progression in chronic renal failure

    DEFF Research Database (Denmark)

    Petersen, L J; Petersen, J R; Talleruphuus, U

    1997-01-01

    The pulsatility index (PI) and the resistive index (RI) are used as pulsed-wave Doppler measurements of downstream renal artery resistance. PI and RI have been found to correlate with renal vascular resistance, filtration fraction and effective renal plasma flow in chronic renal failure. The aim...... of the present study was to evaluate the potential relationship between these indices and the rate of decline in renal function, as reflected by changes in different parameters of renal function in patients with chronic renal failure....

  8. The pulsatility index and the resistive index in renal arteries in patients with hypertension and chronic renal failure

    DEFF Research Database (Denmark)

    Petersen, L J; Petersen, J R; Ladefoged, S D

    1995-01-01

    The pulsatility index (PI) and the resistive index (RI) are used as pulsed-wave Doppler measurement of downstream renal artery resistance. Little information is available on their value in chronic renal failure and their correlation to parameters of renal function and haemodynamics. The aim...... was to compare PI and RI of renal arteries in healthy volunteers and in patients with hypertension and chronic renal failure, and furthermore to study the correlation of these indices to measurements of renal haemodynamics and function by standard methods in patients with renal failure and hypertension....

  9. Fetal umbilical artery Doppler pulsatility index and childhood neurocognitive outcome at 12 years

    OpenAIRE

    Mone, Fionnuala; McConnell, Barbara; Thompson, Andrew; Segurado, Ricardo; Hepper, Peter; Stewart, Moira C.; Dornan, James C; Ong, Stephen; McAuliffe, Fionnuala M.; Shields, Michael D.

    2016-01-01

    OBJECTIVE: To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks' gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years.METHODS: Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years o...

  10. PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method

    International Nuclear Information System (INIS)

    Hong, Hyeon Ji; Ji, Ho Seong; Kim, Kyung Chun

    2016-01-01

    Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent 10° from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

  11. First-trimester measurement of the ductus venosus pulsatility index and the prediction of congenital heart defects

    NARCIS (Netherlands)

    Timmerman, E.; Clur, S. A.; Pajkrt, E.; Bilardo, C. M.

    2010-01-01

    Objective This study was carried out to evaluate the additional predictive value of ductus venosus pulsatility index for veins (DV-PIV) in the identification of congenital heart defects (CHDs) in fetuses with an enlarged nuchal translucency (NT) and a normal karyotype. Methods All chromosomally

  12. The predictive value of the uterine artery pulsatility index during the early third trimester for the occurrence of adverse pregnancy outcomes depending on the maternal obesity.

    Science.gov (United States)

    Kim, Yeon Hee; Lee, Hee Joung; Shin, Jae Eun; Lee, Young; Shin, Jong Chul; Park, Tae Chul; Park, In Yang

    2015-01-01

    To identify the correlation between the pre-gravid maternal obesity and the uterine artery pulsatility index (UtA-PI) at 28-34 weeks' gestation, and to evaluate the predictive value of the UtA-PI for the occurrence of adverse outcomes depending on the maternal obesity. Between January 2010 and December 2011, 229 pregnant women were prospectively observed and analyzed. The UtA-PI during 28-34 weeks' gestation was estimated, with abnormal UtA-PI defined if the value was above the 95th centile for gestational age. The patients were classified, using a cut-off value for body mass index (BMI) of 25kg/m(2), into obese (pre-gravid BMI≥25kg/m(2)) and non-obese (pre-gravid BMIPI and estimated their contributions to adverse outcomes using regression analyses. The occurrence of abnormal UtA-PI in the women with pre-gravid BMI over 25kg/m(2) was significantly higher than those with normal pre-gravid BMI (OR: 2.49; 95% CI: 1.22-5.12). In multivariate analyses, the combination with abnormal UtA-PI and pre-gravid BMI over 25kg/m(2) contributed to the occurrence of preterm delivery (OR: 33.5; 95% CI: 7.63-147.21), gestational diabetes (OR: 3.98; 95% CI: 1.17-13.56) and pregnancy induced hypertension (OR: 12.71; 95% CI: 3.45-46.87), compared to the control group with pre-gravid BMI of 25kg/m(2) and less, and normal UtA-PI. Women with pre-gravid BMI over 25kg/m(2) show increased tendency of abnormal uterine artery pulsatility index during 28-34 weeks, which increases the risk of adverse pregnancy outcomes. Copyright © 2014 Asian Oceanian Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  13. Uterine artery Doppler pulsatility index at 11-38 weeks in ICSI pregnancies with egg donation.

    Science.gov (United States)

    Inversetti, Annalisa; Mandia, Luca; Candiani, Massimo; Cetin, Irene; Larcher, Alessandro; Savasi, Valeria; Papaleo, Enrico; Cavoretto, Paolo

    2018-01-26

    Uterine artery Doppler pulsatility index (UtA-PI) may be different in pregnancies with egg donation (ICSI-ED) as compared to conceptions with autologous intra-cytoplasmatic sperm injection (autologous ICSI) and to spontaneous conceptions (SC). One hundred and ninety-four pregnant women with different modes of conception (MC) were prospectively evaluated: 53 ICSI-ED, 36 autologous ICSI and 105 SC. To evaluate the effects of different MC on PI, multivariable linear regression (MLR) models predicting UtA-PI were fitted after adjustment for maternal age, body mass index, race, parity, smoking status and gestational age. In the first trimester, at MLR, autologous ICSI was not associated with a significantly different UtA-PI [estimate (EST) 0.01; 95% confidence interval (CI) -0.19, 0.2; P=0.9] when compared to SC. Conversely, MC by ICSI-ED was associated with lower first trimester UtA-PI (EST -0.32; CI -0.55, -0.08; P=0.01) when compared to SC. At MLR, MC by autologous ICSI and by ICSI-ED were not associated with significant differences in the second and third trimester UtA-PI when compared to SC. ICSI-ED conception presented lower UtA-PI when compared to SC at 11+0-13+6 weeks but not at later assessments. Correction of UtA-PI measurement specifying the origin of oocyte may be useful in first trimester screening.

  14. Pulsatility Index as a Diagnostic Parameter of Reciprocating Wall Shear Stress Parameters in Physiological Pulsating Waveforms.

    Directory of Open Access Journals (Sweden)

    Idit Avrahami

    Full Text Available Arterial wall shear stress (WSS parameters are widely used for prediction of the initiation and development of atherosclerosis and arterial pathologies. Traditional clinical evaluation of arterial condition relies on correlations of WSS parameters with average flow rate (Q and heart rate (HR measurements. We show that for pulsating flow waveforms in a straight tube with flow reversals that lead to significant reciprocating WSS, the measurements of HR and Q are not sufficient for prediction of WSS parameters. Therefore, we suggest adding a third quantity-known as the pulsatility index (PI-which is defined as the peak-to-peak flow rate amplitude normalized by Q. We examine several pulsating flow waveforms with and without flow reversals using a simulation of a Womersley model in a straight rigid tube and validate the simulations through experimental study using particle image velocimetry (PIV. The results indicate that clinically relevant WSS parameters such as the percentage of negative WSS (P[%], oscillating shear index (OSI and the ratio of minimum to maximum shear stress rates (min/max, are better predicted when the PI is used in conjunction with HR and Q. Therefore, we propose to use PI as an additional and essential diagnostic quantity for improved predictability of the reciprocating WSS.

  15. Pulmonary Artery Pulsatility Index Is Associated With Right Ventricular Failure After Left Ventricular Assist Device Surgery.

    Science.gov (United States)

    Morine, Kevin J; Kiernan, Michael S; Pham, Duc Thinh; Paruchuri, Vikram; Denofrio, David; Kapur, Navin K

    2016-02-01

    Right ventricular failure (RVF) is a major cause of morbidity and mortality after CF-LVAD implantation. We explored the association of pulmonary artery compliance (PAC), pulmonary artery elastance (PAE), and pulmonary artery pulsatility index (PAPi) in addition to established parameters as preoperative determinants of postoperative RVF after CF-LVAD surgery. We retrospectively reviewed 132 consecutive CF-LVAD implantations at Tufts Medical Center from 2008 to 2013. Clinical, hemodynamic, and echocardiographic data were studied. RVF was defined as the unplanned need for a right ventricular assist device or inotrope dependence for ≥14 days. Univariate analysis was performed. RVF occurred in 32 of 132 patients (24%). PAC and PAE were not changed, whereas the PAPi was lower among patients with versus without postoperative RVF (1.32 ± 0.46 vs 2.77 ± 1.16; P < .001). RA pressure, RA to pulmonary capillary wedge pressure ratio (RA:PCWP), and RV stroke work index (RVSWI) were also associated with RVF. Using receiver operating characteristic curve-derived cut-points, PAPi < 1.85 provided 94% sensitivity and 81% specificity (C-statistic = 0.942) for identifying RVF and exceeded the predictive value of RA:PCWP, RVSWI, or RA pressure alone. PAPi is a simple hemodynamic variable that may help to identify patients at high risk of developing RVF after LVAD implantation. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Cerebral Pulsatility Index Is Elevated in Patients with Elevated Right Atrial Pressure.

    Science.gov (United States)

    Lahiri, Shouri; Schlick, Konrad H; Padrick, Matthew M; Rinsky, Brenda; Gonzalez, Nestor; Jones, Heather; Mayer, Stephan A; Lyden, Patrick D

    2018-01-01

    Extracerebral venous congestion can precipitate intracranial hypertension due to obstruction of cerebral blood outflow. Conditions that increase right atrial pressure, such as hypervolemia, are thought to increase resistance to jugular venous outflow and contribute to cerebro-venous congestion. Cerebral pulsatility index (CPI) is considered a surrogate marker of distal cerebrovascular resistance and is elevated with intracranial hypertension. Thus, we sought to test the hypothesis that elevated right atrial pressure is associated with increased CPI compared to normal right atrial pressure. We retrospectively reviewed 61 consecutive patients with subarachnoid hemorrhage. We calculated CPI from transcranial Doppler studies and correlated these with echocardiographic measures of right atrial pressure. CPIs were compared from patients with elevated and normal right atrial pressure. There was a significant difference between CPI obtained from all patients with elevated right atrial pressure compared to those with normal right atrial pressure (P right and left hemispheric CPI from patients with both elevated and normal right atrial pressure. Patients with elevated right atrial pressure had significantly higher CPI compared to patients with normal right atrial pressure. These findings suggest that cerebro-venous congestion due to impaired jugular venous outflow may increase distal cerebrovascular resistance as measured by CPI. Since elevated CPI is associated with poor outcome in numerous neurological conditions, future studies are needed to elucidate the significance of these results in other populations. Copyright © 2017 by the American Society of Neuroimaging.

  17. Pulsatility Index in Aortic Coarctation: A Possible Way to Evaluate Factors Affecting Stenting Outcome

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Keramati

    2012-03-01

    Full Text Available Background: The pulsatility index (PI shows continuous blood flow to the end organs and is a significant factor believed to decrease in aortic coarctation. Correction of this factor is of great importance in the treatment of stenotic lesions of the aorta. However, there are minimal data regarding the trend of changes in the PI after stent implantation. Furthermore, the association between the PI and other echocardiographic indices in patients undergoing stent implantation is unclear. This study was designed to evaluate changes in the PI following stenting and its correlation with other echocardiographic indices. Methods: Twenty-three patients with a diagnosis of aortic coarctation consecutively underwent two-dimensional and Doppler echocardiographic imaging modalities twice (before and after stenting. The patients were divided into two groups based on the percentage of increase in the PI after stenting ( < 50% or ≥ 50%. The relation between the post-stenting PI and the baseline echocardiographic indices was assessed. Results: The PI was increased from 0.89 (SD = 0.30 to 1.75 (SD = 0.51 after stenting (p value < 0.001. Baseline diastolic/systolic velocity (D/S velocity ratio of the abdominal aorta (p value = 0.013, mean velocity (p value = 0.033, and peak gradient of the descending aorta (p value = 0.033 were significantly higher in the patients with ≥ 50% increase in the PI after stenting. Conclusion: Our findings showed that elevation in the PI after stenting was a predictable criterion in patients with aortic coarctation: it was predicted by some baseline clinical and echocardiographic indices. Baseline D/S ratio velocity of the abdominal aorta, mean velocity and peak gradient of the descending aorta, and baseline systolic blood pressure were the statistically significant indices to predict ≥ 50% increase in the PI in our patients.

  18. Increased pulsatility index supports diagnosis of vascular parkinsonism versus idiopathic Parkinson's disease.

    Science.gov (United States)

    Caba, L M; Ferrairó, J I T; Torres, I M; Costa, J F V; Muñoz, R B; Martin, A L

    2017-12-29

    The diagnosis of vascular parkinsonism (VP) is based on a series of clinical criteria and neuroimaging findings. An increase in transcranial Doppler ultrasonography pulsatility index (PI) has been described as a frequent finding in patients with VP. We aimed to confirm this association and to determine the PI value with the highest sensitivity and specificity for diagnosis of VP. PI was determined in all patients admitted to Hospital Universitari i Politècnic La Fe due to parkinsonism between January 2012 and June 2016. We assessed the probability of having VP based on PI values in patients with a definite diagnosis of either VP or idiopathic Parkinson's disease (IPD). A ROC curve was created to determine the PI value with the highest sensitivity and specificity. We assessed a total of 146 patients with suspected parkinsonism; 54 (37%) were diagnosed with IPD and 15 (10%) with VP. Patients with VP were significantly older than those with IPD (mean age of 79 vs 68.5, P=.00144) and had a higher PI (median of 1.29 [IQR: 1.09-1.38] vs 0.96 [IQR: 0.89-1.16], P=.01328). In our sample, a PI of 1.09 conferred 84% sensitivity and 70% specificity. In our series, the PI was significantly higher in patients with VP than in those with IPD. We therefore support the use of transcranial Doppler ultrasonography for the initial assessment of elderly patients with akinetic-rigid syndrome. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Reference ranges for uterine artery pulsatility index during the menstrual cycle: a cross-sectional study.

    Science.gov (United States)

    Guedes-Martins, Luís; Gaio, Rita; Saraiva, Joaquim; Cerdeira, Sofia; Matos, Liliana; Silva, Elisabete; Macedo, Filipe; Almeida, Henrique

    2015-01-01

    Cyclic endometrial neoangiogenesis contributes to changes in local vascular patterns and is amenable to non-invasive assessment with Doppler sonography. We hypothesize that the uterine artery (UtA) impedance, measured by its pulsatility index (PI), exhibits a regular pattern during the normal menstrual cycle. Therefore, the main study objective was to derive normative new day-cycle-based reference ranges for the UtA-PI during the entire cycle from days 1 to 34 according to the isolated time effect and potential confounders such as age and parity. From January 2009 to December 2012, a cross-sectional study of 1,821 healthy women undergoing routine gynaecological ultrasound was performed. The Doppler flow of the right and left UtA-PI was studied transvaginally by colour and pulsed Doppler imaging. The mean right and left values and the presence or absence of a bilateral protodiastolic notch were recorded. Reference intervals for the PI according to the cycle day were generated by classical linear regression. The majority of patients (97.5%) presented unilateral or bilateral UtA notches. The crude 5th, 50th, and 95th reference percentile curves of the UtA-PI at 1-34 days of the normal menstrual cycle were derived. In all curves, a progressive significant decrease occurred during the first 13 days, followed by an increase and recovery in the UtA-PI. The adjusted 5th, 50th, and 95th reference percentile curves for the effects of age and parity were also obtained. These two conditions generated an approximately identical UtA-PI pattern during the cycle, except with small but significant reductions at the temporal extremes. The median, 5th, and the 95th percentiles of the UtA-PI decrease during the first third of the menstrual cycle and recover to their initial values during the last two thirds of the cycle. The rates of decrease and recovery depend significantly on age and parity.

  20. Reference ranges for uterine artery pulsatility index during the menstrual cycle: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Luís Guedes-Martins

    Full Text Available Cyclic endometrial neoangiogenesis contributes to changes in local vascular patterns and is amenable to non-invasive assessment with Doppler sonography. We hypothesize that the uterine artery (UtA impedance, measured by its pulsatility index (PI, exhibits a regular pattern during the normal menstrual cycle. Therefore, the main study objective was to derive normative new day-cycle-based reference ranges for the UtA-PI during the entire cycle from days 1 to 34 according to the isolated time effect and potential confounders such as age and parity.From January 2009 to December 2012, a cross-sectional study of 1,821 healthy women undergoing routine gynaecological ultrasound was performed. The Doppler flow of the right and left UtA-PI was studied transvaginally by colour and pulsed Doppler imaging. The mean right and left values and the presence or absence of a bilateral protodiastolic notch were recorded. Reference intervals for the PI according to the cycle day were generated by classical linear regression.The majority of patients (97.5% presented unilateral or bilateral UtA notches. The crude 5th, 50th, and 95th reference percentile curves of the UtA-PI at 1-34 days of the normal menstrual cycle were derived. In all curves, a progressive significant decrease occurred during the first 13 days, followed by an increase and recovery in the UtA-PI. The adjusted 5th, 50th, and 95th reference percentile curves for the effects of age and parity were also obtained. These two conditions generated an approximately identical UtA-PI pattern during the cycle, except with small but significant reductions at the temporal extremes.The median, 5th, and the 95th percentiles of the UtA-PI decrease during the first third of the menstrual cycle and recover to their initial values during the last two thirds of the cycle. The rates of decrease and recovery depend significantly on age and parity.

  1. High-flavanol and high-theobromine versus low-flavanol and low-theobromine chocolate to improve uterine artery pulsatility index: a double blind randomized clinical trial.

    Science.gov (United States)

    Bujold, Emmanuel; Leblanc, Vicky; Lavoie-Lebel, Élise; Babar, Asma; Girard, Mario; Poungui, Lionel; Blanchet, Claudine; Marc, Isabelle; Lemieux, Simone; Belkacem, Abdous; Sidi, Elhadji Laouan; Dodin, Sylvie

    2017-09-01

    To evaluate the impact of high-flavanol and high-theobromine (HFHT) chocolate in women at risk of preeclampsia (PE). We conducted a single-center randomized controlled trial including women with singleton pregnancy between 11 and 14 weeks gestation who had bilateral abnormal uterine artery (UtA) waveforms (notching) and elevated pulsatility index (PI). Participants were randomized to either HFHT or low-flavanol and low-theobromine (LFLT) chocolate (30 grams daily for a total of 12 weeks). UtA PI, reported as multiple of medians (MoM) adjusted for gestational age, was assessed at baseline and 12 weeks after randomization. One hundred thirty-one women were randomized with mean gestational age of 12.4 ± 0.6 weeks and a mean UtA PI of 1.39 ± 0.31 MoM. UtA PI adjusted for gestational age significantly decreased from baseline to the second visit (12 weeks later) in the two groups (p UtA PI. Nevertheless, the improvement observed in both groups suggests that chocolate could improve placental function independently of flavanol and/or theobromine content.

  2. Insulin receptor signaling in the GnRH neuron plays a role in the abnormal GnRH pulsatility of obese female mice.

    Directory of Open Access Journals (Sweden)

    Sara A DiVall

    Full Text Available Infertility associated with obesity is characterized by abnormal hormone release from reproductive tissues in the hypothalamus, pituitary, and ovary. These tissues maintain insulin sensitivity upon peripheral insulin resistance. Insulin receptor signaling may play a role in the dysregulation of gonadotropin-releasing hormone (GnRH secretion in obesity, but the interdependence of hormone secretion in the reproductive axis and the multi-hormone and tissue dysfunction in obesity hinders investigations of putative contributing factors to the disrupted GnRH secretion. To determine the role of GnRH insulin receptor signaling in the dysregulation of GnRH secretion in obesity, we created murine models of diet-induced obesity (DIO with and without intact insulin signaling in the GnRH neuron. Obese control female mice were infertile with higher luteinizing hormone levels and higher GnRH pulse amplitude and total pulsatile secretion compared to lean control mice. In contrast, DIO mice with a GnRH specific knockout of insulin receptor had improved fertility, luteinizing hormone levels approaching lean mice, and GnRH pulse amplitude and total secretion similar to lean mice. Pituitary responsiveness was similar between genotypes. These results suggest that in the obese state, insulin receptor signaling in GnRH neurons increases GnRH pulsatile secretion and consequent LH secretion, contributing to reproductive dysfunction.

  3. Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke

    International Nuclear Information System (INIS)

    Bok, Tae Hoon; Kong, Qi; Nam, Kweon Ho; Choi, Jay Chol; Paeng, Dong Guk

    2012-01-01

    In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group (0.13±0.21 and 0.16±0.03). PIBE of CCA for the young group, however, was larger than that for the old group (0.70±0.21 and 0.32±0.01), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients (336±61 and 340±126 mg/dl) were more than that of the control group (264±38 and 43 mg/dl), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

  4. Predictive Value of Middle Cerebral Artery to Uterine Artery Pulsatility Index Ratio in Hypertensive Disorders of Pregnancy

    Directory of Open Access Journals (Sweden)

    Prashanth Adiga

    2015-01-01

    Full Text Available Aims and Objectives. (i To determine the predictive value of cerebrouterine (CU ratio (middle cerebral artery to uterine artery pulsatility index, MCA/UT PI in assessing perinatal outcome among hypertensive disorders of pregnancy. (ii To compare between CU ratio and CP ratio (MCA/Umbilical artery PI as a predictor of adverse perinatal outcome. Methods. A prospective observational study was done in a tertiary medical college hospital, from September 2012 to August 2013. One hundred singleton pregnancies complicated by hypertension peculiar to pregnancy were enrolled. Both CU and CP ratios were estimated. The perinatal outcomes were studied. Results. Both cerebrouterine and cerebroplacental ratios had a better negative predictive value in predicting adverse perinatal outcome. However, both CU and CP ratios when applied together were able to predict adverse outcomes better than individual ratios. The sensitivity, specificity, positive predictive value, and the negative predictive values for an adverse neonatal outcome with CU ratio were 61.3%, 70.3%, 56%, and 78.9%, respectively, compared to 42%, 57.5%, 62%, and 76% as with CP ratio. Conclusion. Cerebrouterine ratio and cerebroplacental ratio were complementary to each other in predicting the adverse perinatal outcomes. Individually, both ratios were reassuring for favorable perinatal outcome with high negative predictive value.

  5. A mixture model of ductus venosus pulsatility index in screening for aneuploidies at 11-13 weeks' gestation.

    Science.gov (United States)

    Maiz, Nerea; Wright, David; Ferreira, Ana Fatima A; Syngelaki, Argyro; Nicolaides, Kypros H

    2012-01-01

    To assess the value of ductus venosus pulsatility index for veins (DV PIV) in screening for aneuploidies at 11-13 weeks' gestation. Fetal DV PIV was measured in singleton pregnancies undergoing first-trimester screening for aneuploidies. In euploid (n = 44,756) and aneuploid (202 cases of trisomy 21, 72 cases of trisomy 18 and 30 cases of trisomy 13) fetuses, DV PIV was best described by a mixture model of distributions. Performance of screening for aneuploidies by DV PIV alone and in combination with fetal nuchal translucency (NT) thickness and serum free β-hCG and PAPP-A was estimated. In euploid pregnancies there was a bimodal distribution of DV PIV with a dominant crown-rump length (CRL)-dependent part, accounting for around 97% of cases in Caucasians and around 93% in Afro-Caribbeans, and a smaller CRL-independent distribution. In aneuploidies the dominant part was the CRL-independent distribution, which accounted for around 85% cases of trisomies 21 and 18 and 70% of cases of trisomy 13. In screening for trisomy 21 by maternal age, NT and biochemistry at a risk cutoff of 1 in 100, the detection rate was 89.7% and false positive rate was 2.74%; with addition of DV PIV, the values were 93.5 and 1.63%, respectively. Measurement of DV PIV improves the performance of first-trimester combined test for aneuploidies. Copyright © 2012 S. Karger AG, Basel.

  6. Abnormal resting-state functional connectivity study in unilateral pulsatile tinnitus patients with single etiology: A seed-based functional connectivity study

    International Nuclear Information System (INIS)

    Lv, Han; Zhao, Pengfei; Liu, Zhaohui; Li, Rui; Zhang, Ling; Wang, Peng; Yan, Fei; Liu, Liheng; Wang, Guopeng; Zeng, Rong; Li, Ting; Dong, Cheng; Gong, Shusheng; Wang, Zhenchang

    2016-01-01

    Objective: Previous studies demonstrated altered regional neural activations in several brain areas in patients with pulsatile tinnitus (PT), especially indicating an important role of posterior cingulate cortex (PCC). However, few studies focused on the degree of functional connectivity (FC) of this area in PT patients. In this study, we will compare the FC of PCC in patients affected with this condition and normal controls by using resting-state functional magnetic resonance imaging (fMRI). Methods: Structural and functional MRI data were obtained from 36 unilateral PT patients with single etiology and 36 matched healthy controls. FC feature of the region of interest (PCC) were characterized using a seed-based correlation method with the voxels in the whole-brain. Results: Compared with healthy controls, patients showed significant decreased FC to the right middle temporal gyrus (MTG), right thalamus and bilateral insula. By contrast, PCC demonstrated increased functional connectivity between the precuneus, bilateral inferior parietal lobule and middle occipital gyrus. We also found correlations between the disease duration of PT and FC of PCC-right MTG (r = −0.616, p < 0.001). Conclusions: Unilateral PT patients could have abnormal FC to the PCC bilaterally in the brain. PCC, as a highly integrated brain area, is an example of nucleus that was involved in mediation between different neural networks. It might be a modulation core between visual network and auditory network. The decreased FC of MTG to PCC may indicate a down regulation of activity between PCC and auditory associated brain cortex. Decreased FC between limbic system (bilateral AI) and PCC may reflect the emotional message control in patient group. This study facilitated understanding of the underlying neuropathological process in patients with pulsatile tinnitus.

  7. Abnormal resting-state functional connectivity study in unilateral pulsatile tinnitus patients with single etiology: A seed-based functional connectivity study

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Han [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Neuroradiology Division, Department of Radiology, Stanford University, CA, 94305 (United States); Zhao, Pengfei [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Liu, Zhaohui [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730 (China); Li, Rui; Zhang, Ling; Wang, Peng [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Yan, Fei [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730 (China); Liu, Liheng [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Wang, Guopeng; Zeng, Rong [Department of Otolaryngology Head and Neck Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Li, Ting [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730 (China); Dong, Cheng [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Gong, Shusheng, E-mail: gongss@ccmu.edu.cn [Department of Otolaryngology Head and Neck Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China); Wang, Zhenchang, E-mail: cjr.wzhch@vip.163.com [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050 (China)

    2016-11-15

    Objective: Previous studies demonstrated altered regional neural activations in several brain areas in patients with pulsatile tinnitus (PT), especially indicating an important role of posterior cingulate cortex (PCC). However, few studies focused on the degree of functional connectivity (FC) of this area in PT patients. In this study, we will compare the FC of PCC in patients affected with this condition and normal controls by using resting-state functional magnetic resonance imaging (fMRI). Methods: Structural and functional MRI data were obtained from 36 unilateral PT patients with single etiology and 36 matched healthy controls. FC feature of the region of interest (PCC) were characterized using a seed-based correlation method with the voxels in the whole-brain. Results: Compared with healthy controls, patients showed significant decreased FC to the right middle temporal gyrus (MTG), right thalamus and bilateral insula. By contrast, PCC demonstrated increased functional connectivity between the precuneus, bilateral inferior parietal lobule and middle occipital gyrus. We also found correlations between the disease duration of PT and FC of PCC-right MTG (r = −0.616, p < 0.001). Conclusions: Unilateral PT patients could have abnormal FC to the PCC bilaterally in the brain. PCC, as a highly integrated brain area, is an example of nucleus that was involved in mediation between different neural networks. It might be a modulation core between visual network and auditory network. The decreased FC of MTG to PCC may indicate a down regulation of activity between PCC and auditory associated brain cortex. Decreased FC between limbic system (bilateral AI) and PCC may reflect the emotional message control in patient group. This study facilitated understanding of the underlying neuropathological process in patients with pulsatile tinnitus.

  8. Clinical outcomes of pulsatile and non-pulsatile mode of perfusion.

    Science.gov (United States)

    Haines, Nikkole; Wang, Shigang; Undar, Akif; Alkan, Tijen; Akcevin, Atif

    2009-03-01

    A longstanding debate remains over whether or not pulsatile flow provides better perfusion during cardiopulmonary bypass (CPB). This paper provides a guide for clinical investigation, as well as current laboratory and clinical evidence concerning pulsatile and non-pulsatile perfusion. This evidence is in the form of in vitro and in vivo experiments and clinical trials. We review the literature and provide personal experience from the Pediatric Cardiac Research Laboratories at the Penn State Hershey Children's Hospital. Pulsatility is emerging as the preferred perfusion method for CPB. Clinical evidence show better cardiac, renal, and pulmonary outcomes in patients receiving pulsatile perfusion. Furthermore, better cytokine, endothelin, and hormone levels and a higher respiratory index are shown in pulsatile perfusion modes compared with non-pulsatile perfusion modes. In recent years, evidence has amounted that supports a shift toward pulsatility in these procedures over non-pulsatility. Currently, more evaluation of circuit components and patient outcomes is needed.

  9. Reproducibility of first- and second-trimester uterine artery pulsatility index measured by transvaginal and transabdominal ultrasound.

    Science.gov (United States)

    Ferreira, A E G M T; Mauad Filho, F; Abreu, P S G; Mauad, F M; Araujo Júnior, E; Martins, W P

    2015-11-01

    To examine and compare the reproducibility of measurement of first- and second-trimester uterine artery pulsatility index (UtA-PI) using transabdominal (TAS) and transvaginal (TVS) ultrasound. This was an observational study including women ≥ 18 years of age, with a singleton pregnancy, in the first trimester (between 11 + 0 and 13 + 6 weeks' gestation) or second trimester (between 20 and 26 weeks' gestation). UtA-PI and angle of insonation were assessed by two observers (one with 15 and the other with 3 years of experience) using both TAS and TVS. The more experienced observer performed two scans alternated by the other observer. The acquisitions were completely independent and the observers were blinded to each other and to their own measurements. Reproducibility of the measurements by TVS and TAS was assessed using the concordance correlation coefficients (CCCs), intraclass correlation coefficients (ICCs) and limits of agreement (LoA). We analyzed data from 97 women in the first trimester and 96 in the second trimester. The mean ± SD UtA-PI was significantly higher when measured using TVS, compared with TAS, in both the first (1.60 ± 0.49 vs 1.52 ± 0.63, respectively; P = 0.03) and second (1.07 ± 0.33 vs 0.96 ± 0.32, respectively; P UtA-PI, assessment by TVS provides higher values and better insonation angle compared with TAS. The reproducibility of the ultrasound methods in both first and second trimesters of pregnancy was comparable and should not be considered as good. Future studies examining technical improvements with the aim of increasing the reproducibility of this technique should be encouraged. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  10. Do Flow and Pulsatility Index within the Accepted Ranges Predict Long-Term Outcomes after Coronary Artery Bypass Grafting?

    Science.gov (United States)

    Leon, Maximiliano De; Stanham, Roberto; Soca, Gerardo; Dayan, Victor

    2017-04-12

    Background  Transit-time flow measurement (TTFM) is the gold standard for intraoperative detection of graft failure. Several reports show that TTFM and distal coronary bed quality (DCBQ) may also be useful for midterm detection of graft failure. Nonetheless, there are no data regarding their predictive role on long-term outcomes. Methods  Patients with three-vessel disease who underwent isolated coronary artery bypass grafting (CABG) in 2006 and received at least one graft to the left anterior descending artery (LAD) or to the first obtuse marginal (OM1) or posterior descending artery (PDA) were included. Baseline characteristics, mean graft flow, pulsatility index, and subjective impression of DCBQ for each coronary territory were collected. Long-term cardiovascular (CV) and overall survival, operative mortality, and new percutaneous coronary intervention (PCI) were evaluated. Results  A total of 177 patients underwent isolated CABG. The OM1 was grafted in 131 patients, the LAD in 169 patients, and the PDA in 100 patients. Neither DQCB nor TTFM were predictors for new PCI. Independent predictors for overall survival were age, previous acute myocardial infarction (AMI), and DQCB of OM1 (odds ratio [OR] = 2.97; 95% confidence interval [CI]: 1.15-7.71). Age, previous AMI, and DCBQ of OM1 (OR = 2.5; 95% CI: 1.39-4.81) were independent predictors for CV survival. Conclusions  TTFM on patients with functioning grafts does not predict long-term survival or performance of new PCI. Subjective evaluation of distal coronary bed, especially of the OM1, has a strong impact on long-term outcomes. Georg Thieme Verlag KG Stuttgart · New York.

  11. Uterine artery pulsatility index in the three trimesters of pregnancy: effects of maternal characteristics and medical history.

    Science.gov (United States)

    Tayyar, A; Guerra, L; Wright, A; Wright, D; Nicolaides, K H

    2015-06-01

    To define the contribution of maternal variables that influence the measured uterine artery pulsatility index (UtA-PI) in screening for pregnancy complications. Maternal characteristics and medical history were recorded, and UtA-PI was measured, in women with a singleton pregnancy attending for three routine hospital visits at 11 + 0 to 13 + 6 weeks, 19 + 0 to 24 + 6 weeks and 30 + 0 to 34 + 6 weeks or 35 + 0 to 37 + 6 weeks' gestation. For pregnancies delivering phenotypically normal live births or stillbirths at ≥ 24 weeks' gestation, variables from maternal demographic characteristics and medical history that are important in the prediction of UtA-PI were determined from linear mixed-effects multiple regression. UtA-PI was measured in 90 484 cases in the first trimester, 66 862 cases in the second trimester and 33 470 cases in the third trimester of pregnancy. Significant independent contributions to UtA-PI were provided by gestational age, maternal age, weight, racial origin and a history of pre-eclampsia (PE) in the previous pregnancy. Random-effects multiple regression analysis was used to define the contribution of maternal variables that influence the measured UtA-PI and express the values as multiples of the median (MoM). The model was shown to provide an adequate fit of MoM values for all covariates both in pregnancies that developed PE and in those that did not. A model was fitted to express the measured UtA-PI as MoMs after adjustment for variables from maternal characteristics and medical history that affect this measurement. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  12. Abnormalities of the Single-Rooted Anterior Teeth: An Index for ...

    African Journals Online (AJOL)

    ) in the compared abnormalities of the single-rooted anterior teeth; indicating that the abnormalities of the single-rooted anterior teeth can serve as index for early detection of DM. Keywords: Diabetes mellitus, Epidemic, Diagnosis, Teeth, ...

  13. Hemodialysis using a valveless pulsatile blood pump.

    Science.gov (United States)

    Lee, Kyungsoo; Mun, Cho Hae; Lee, Sa Ram; Min, Byoung Goo; Yoo, Kyu Jae; Park, Yong Woo; Won, Yong Soon

    2008-01-01

    Research on pulsatile blood pumps for extracorporeal life support has been widely performed because of the proven advantageous effects of blood pulsation. However, studies on the use of pulsatile blood pumps for hemodialysis are limited, although available evidence demonstrates that pulsatile blood flow has a positive influence on dialysis outcome. Therefore, the authors designed a new pulsatile pump, which is characterized by minimal-occlusion of blood-containing tubing, no requirement for valves, and no blood flow regurgitation. In-vitro hemolysis tests were conducted using fresh bovine blood, and the normalized index of hemolysis was adopted to compare blood traumas induced by the devised pulsatile pump and a conventional roller pump. In addition, experimental hemodialyses with a canine renal failure model were performed using the devised pump. Normalized index of hemolysis levels obtained was much smaller for the devised pulse pump (45 +/- 21 mg/100 L) than for the roller pump (103 +/- 10 mg/100 L), and no technical problems were encountered during dialysis sessions. Blood and dialysate flow rates were maintained at predetermined values and molecular removal was satisfactory. Postdialysis urea and creatinine reduction ratios were 61.8% +/- 10.6% and 57.4% +/- 9.0%, respectively. Pulsatile flow has usually been generated using pulsatile devices containing valves, but the valves cause concern in terms of the clinical applications of these devices. However, the described pulsatile pump does not require valves, and yet no blood flow regurgitation was observed.

  14. Reference values for placental growth factor (PlGF) concentration and uterine artery doppler pulsatility index (PI) at 11-13(+6) weeks of gestation in the Polish population.

    Science.gov (United States)

    Kosiński, Przemysław; Samaha, Robert Brawura Biskupski; Bomba-Opoń, Dorota A; Kozłowski, Szymon; Lipa, Michał; Kaczyński, Bartosz; Zbucka-Kretowska, Monika; Lawicki, Sławomir; Szmitkowski, Maciej; Wolczyński, Sławomir; Wielgoś, Mirosław

    2014-07-01

    The aim of the study was to determine placental growth factor (PIGF) concentration and uterine artery (UtA) Doppler pulsatility index (PI) at 11-13(+6) weeks of gestation in the Polish population. A prospective study was performed in pregnant women who underwent routine ultrasound scan at 11-13(+6) weeks of gestation. All participants completed a questionnaire about their medical history demographics and current pregnancy. Mean arterial pressure (MAP) was calculated. Gestational age was confirmed by CRL and mean UtA PI was calculated. Blood samples were taken to measure beta HCG, PAPP-A and P/GF concentrations. Out of the 577 analyzed participants, 60 (10.4%) were found to have abnormal placentation disorders (20 -hypertensive disorders and 40-IUGR). The patients were subdivided into two groups, depending on pregnancy outcome: unaffected (n = 517) and affected (n = 60). The study did not confirm the anticipated correlation between maternal BMI and PIGF, but the concentration of PIGF was significantly increased in smokers. UtA PI values were not statistically significantly different depending on maternal age, BMI, method of conception, smoking or parity The study confirms that both, UtA PI and PIGF concentrations are CRL-dependent. Median MoM values for PIGF and UtA PI were obtained for each set of CRL measurements. Median PIGF MoM was decreased in pregnancies complicated by hypertensive disorders and IUGR as compared to the unaffected group. The established reference ranges for UtA PI and PIGF at 11-13(+6) weeks of gestation may be of clinical value in predicting placenta-associated diseases in early stages of pregnancy in the Polish population.

  15. [Abnormality of blood coagulation indexes in patients with de novo acute leukemia and its clinical significance].

    Science.gov (United States)

    Xiao, Fang-Fang; Hu, Kai-Xun; Guo, Mei; Qiao, Jian-Hui; Sun, Qi-Yun; Ai, Hui-Sheng; Yu, Chang-Lin

    2013-04-01

    To explore hemorrhage risk and the clinical significance of abnormal change of prothrombin time (PT), activated partial thromboplastin time (APTT), plasma fibrinogen (FIB), plasma thrombin time (TT) and d-dimer (D-D) in de novo acute leukemia (except for APL), the different bleeding manifestations of 114 cases of de novo acute leukemia with different coagulation indexes were analyzed retrospectively. The correlation between these blood coagulation indexes and the possible correlative clinical characteristics were analysed, including age, sex, type of acute leukemia, initial white blood cell(WBC) and platelet(Plt) count, the proportion of blast cells in bone marrow and cytogenetic abnormality of patients at diagnosis. The results indicated that the incidence of abnormal blood coagulation was as high as 78.1% for de novo AL patients. These patients with 5 normal blood coagulation indexes may have mild bleeding manifestation, but the more abnormal indexes, the more severe bleeding. Both PT and D-D were sensitive indexes for diagnosis of level II bleeding. Incidence of abnormal blood coagulation significantly correlates with the proportion of blast cells in bone marrow (χ(2) = 4.184, OR = 1.021, P coagulation. It is concluded that the coagulation and fibrinolysis are abnormal in most patients with de novo acute leukemia. More abnormal indexes indicate more severe bleeding, and both PT and D-D are sensitive indexes for diagnosis of level II bleeding. Higher proportion of blast cells in bone marrow predicts higher incidence of abnormal blood clotting. Acute leukemia with elderly age, high white blood cell count and adverse cytogenetics do not predict severer abnormal blood clotting. Detection of PT, APTT, TT, FIB, and D-D may help to judge whether the patients are in a state of hypercoagulability or disseminated intravenous coagulation, which will provide experiment evidences for early intervention and medication.

  16. PP057. The role of uterine artery pulsatility index for prediction of pregnancy outcome, in women affected by pre-eclampsia.

    Science.gov (United States)

    Gregorini, M E; Gerosa, V; Rovida, P L; Pagani, G; Platto, C; Valcamonico, A; Lojacono, A; Frusca, T

    2012-07-01

    Uterine artery (UtA) Pulsatility index assessed in the second trimester is known to be the best predictor of Pre-eclampsia (PE) in women with risk factors. The role of this index when PE occurs seems to be related with clinical outcome. To detect if there does exist a correlation between mean UtA PI, assessed at diagnosis of PE, and: (A) Gestational Age (GA) at delivery; (B) birth weight (BW) percentile. To detect the predictive value of mean UtA PI and the development of adverse pregnancy outcome (APO). Cohort study on 100 consecutive singleton pregnancies complicated with pre-eclampsia referred to our Department from January 2010 and December 2011. Doppler evaluations were performed from diagnosis to delivery. Mean UtA PI obtained at time of diagnosis of PE were analysed. PE was defined according to ISSHP criteria. Clinical and perinatal outcomes were reviewed. APO was defined as Apgar score less than 7 at five minutes, pH One case of stillbirth and four cases of neonatal death were observed. SGA occurred in 56/100 neonates; 52/95 (55%) live births were admitted to Neonatal Intensive Care Unit. Table 1. Mean UtA PI at diagnosis of PE was 1.40 (SD±0.28) in women that developed APO and 1.10 (SD±0.41) in women that did not develop APO (p=0.02). Pearson's Correlation coefficient for mean UtA PI and GA at Delivery was -0.533 (p=0.002); while for mean UtA PI and BW percentile was -0.466 (p=0.007). The prediction of subsequent development of APO, expressed as the area under ROC curve, was 61.6 (95% CI 0.44-0.79) for UtA PI at Diagnosis of PE. Our data confirm that mean UtA PI, assessed at diagnosis of PE, represent a good independent predictor for GA at delivery end BW percentile. However the predictive value for development of APO seems to be poor. Copyright © 2012. Published by Elsevier B.V.

  17. Inner Ear Conductive Hearing Loss and Unilateral Pulsatile Tinnitus Associated with a Dural Arteriovenous Fistula: Case Based Review and Analysis of Relationship between Intracranial Vascular Abnormalities and Inner Ear Fluids

    Directory of Open Access Journals (Sweden)

    Ettore Cassandro

    2015-01-01

    Full Text Available While pulsatile tinnitus (PT and dural arteriovenous fistula (DAVF are not rarely associated, the finding of a conductive hearing loss (CHL in this clinical picture is unusual. Starting from a case of CHL and PT, diagnosed to be due to a DAVF, we analyzed relationship between intracranial vascular abnormalities and inner ear fluids. DAVF was treated with endovascular embolization. Following this, there was a dramatic recovery of PT and of CHL, confirming their cause-effect link with DAVF. We critically evaluated the papers reporting this association. This is the first case of CHL associated with PT and DAVF. We describe the most significant experiences and theories reported in literature, with a personal analysis about the possible relationship between vascular intracranial system and labyrinthine fluids. In conclusion, we believe that this association may be a challenge for otolaryngologists. So we suggest to consider the possibility of a DAVF or other AVMs when PT is associated with CHL, without alterations of tympanic membrane and middle ear tests.

  18. Imaging in pulsatile tinnitus

    International Nuclear Information System (INIS)

    Madani, G.; Connor, S.E.J.

    2009-01-01

    Tinnitus may be continuous or pulsatile. Vascular lesions are the most frequent radiologically demonstrable cause of pulsatile tinnitus. These include congenital vascular anomalies (which may be arterial or venous), vascular tumours, and a variety of acquired vasculopathies. The choice of imaging depends on the clinical findings. If a mass is present at otoscopy, thin-section computed tomography (CT) is indicated. In the otoscopically normal patient, there is a range of possible imaging approaches. However, combined CT angiography and venography is particularly useful

  19. Imaging in pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Madani, G. [Radiology Department, St Mary' s Hospital, London (United Kingdom)], E-mail: gittamadani@yahoo.com; Connor, S.E.J. [Neuroradiology Department, King' s College Hospital, London (United Kingdom)

    2009-03-15

    Tinnitus may be continuous or pulsatile. Vascular lesions are the most frequent radiologically demonstrable cause of pulsatile tinnitus. These include congenital vascular anomalies (which may be arterial or venous), vascular tumours, and a variety of acquired vasculopathies. The choice of imaging depends on the clinical findings. If a mass is present at otoscopy, thin-section computed tomography (CT) is indicated. In the otoscopically normal patient, there is a range of possible imaging approaches. However, combined CT angiography and venography is particularly useful.

  20. Surface-length index: a novel index for rapid detection of right ventricles with abnormal ejection fraction using cardiac MRI.

    Science.gov (United States)

    Bonnemains, Laurent; Mandry, Damien; Menini, Anne; Stos, Bertrand; Felblinger, Jacques; Marie, Pierre-Yves; Vuissoz, Pierre-Andre

    2013-09-01

    To validate a new index, the surface-length index (SLI) based on area change in a short-axis view and length reduction in the horizontal long-axis view, which is used to quickly (right ventricles with an abnormal ejection fraction (EF) during a cardiac MRI examination. SLI can be used to avoid a complete delineation of the endocardial contours of normal right ventricles. Sixty patients (group A) were retrospectively included to calibrate the SLI formula by optimisation of the area under the ROC curves and SLI thresholds were chosen to obtain 100 % sensitivity. Another 340 patients (group B) were prospectively recruited to test SLI's capacity to detect right ventricles (RVs) with an abnormal EF (right ventricle ejection fraction (RVEF) with cine-MRI is time consuming. • Therefore, RVEF is not always assessed during cardiac MRI. • Surface-length index (SLI) allows rapid detection of abnormal RVEF during cardiac MRI. • SLI saves one third of the operator time. • Every cardiac MRI could include RVEF assessment by means of SLI.

  1. Reference centiles for the middle cerebral artery and umbilical artery pulsatility index and cerebro-placental ratio from a low-risk population - a Generalised Additive Model for Location, Shape and Scale (GAMLSS) approach.

    Science.gov (United States)

    Flatley, Christopher; Kumar, Sailesh; Greer, Ristan M

    2018-02-06

    The primary aim of this study was to create reference ranges for the fetal Middle Cerebral artery Pulsatility Index (MCA PI), Umbilical Artery Pulsatility Index (UA PI) and the Cerebro-Placental Ratio (CPR) in a clearly defined low-risk cohort using the Generalised Additive Model for Location, Shape and Scale (GAMLSS) method. Prospectively collected cross-sectional biometry and Doppler data from low-risk women attending the Mater Mother's Hospital, Maternal and Fetal Medicine Department in Brisbane, Australia between January 2010 and April 2017 were used to derive gestation specific centiles for the MCA PI, UA PI and CPR. All ultrasound scans were performed between 18 + 0 and 41 + 6 weeks gestation with recorded data for the MCA PI and/or UA PI. The GAMLSS method was used for the calculation of gestational age-adjusted centiles. Distributions and additive terms were assessed and the final model was chosen on the basis of the Global Deviance, Akaike information criterion (AIC) and Schwartz bayesian criterion (SBC), along with the results of the model and residual diagnostics as well as visual assessment of the centiles themselves. Over the study period 6013 women met the inclusion criteria. The MCA PI was recorded in 4473 fetuses, the UA PI in 6008 fetuses and the CPR was able to be calculated in 4464 cases. The centiles for the MCA PI used a fractional polynomial additive term and Box-Cox t (BCT) distribution. Centiles for the UA PI used a cubic spline additive term with BCT distribution and the CPR used a fractional polynomial additive term and a BCT distribution. We have created gestational centile reference ranges for the MCA PI, UA PI and CPR from a large low-risk cohort that supports their applicability and generalisability.

  2. Elevated augmentation index derived from peripheral arterial tonometry is associated with abnormal ventricular-vascular coupling.

    Science.gov (United States)

    Heffernan, Kevin S; Patvardhan, Eshan A; Hession, Michael; Ruan, Jenny; Karas, Richard H; Kuvin, Jeffrey T

    2010-09-01

    Although typically derived from the contour of arterial pressure waveform, augmentation index (AIx) may also be derived from the digital pulse volume waveform using finger plethysmography (peripheral arterial tonometry, PAT). Little is known regarding the physiologic correlates of AIx derived from PAT. In this study, we investigated the relation of PAT-AIx with measures of ventricular-vascular coupling. Pulse volume waves were measured via PAT and used to derive AIx. Using 2-dimensional echocardiography, effective arterial elastance index (EaI) was estimated as end-systolic pressure/stroke volume index. Left ventricular (LV) end-systolic elastance index (E(LV)I) was calculated as end-systolic pressure/end-systolic volume index. Ventricular-vascular coupling ratio was defined as EaI/E(LV)I. Given the bi-directional nature of ventricular-vascular uncoupling as measured by echocardiography, patients were separated into three groups: low EaI/E(LV)I (EaI/E(LV)I (mean 0.6-1.2, n = 16) and high EaI/E(LV)I (>1.2, n = 10). Adjusting for potential confounders (age, mean arterial pressure, height and heart rate), patients with optimal EaI/E(LV)I had lower AIx (1 +/- 4%, PEaI/E(LV)I (13 +/- 4%) and high EaI/E(LV)I (19 +/- 5%). Abnormal ventricular-vascular coupling, arising from either increased effective arterial elastance or increased ventricular elastance, is associated with increased AIx as measured by PAT. Additional research is needed to examine other vascular correlates of PAT-AIx.

  3. Association between maternal vascular murmur and the small-for-gestational-age fetus with abnormal umbilical artery Doppler flow

    DEFF Research Database (Denmark)

    Riknagel, Diana; Farlie, Richard; Hedegaard, Morten

    2017-01-01

    OBJECTIVE: To investigate the association between maternal vascular murmurs (MVMs) and fetal growth restriction (defined as small-for-gestational-age [SGA] fetus) and abnormal Doppler pulsatility index (PI) of the uterine and/or umbilical arteries. METHODS: A cross-sectional study of women aged 18...... participants had MVMs. There was a clear association between MVMs and a composite of SGA and an abnormal PI of the uterine and/or the umbilical artery (P

  4. Effect of Acute Resistance Exercise on Carotid Artery Stiffness and Cerebral Blood Flow Pulsatility

    Directory of Open Access Journals (Sweden)

    Wesley K Lefferts

    2014-03-01

    Full Text Available Arterial stiffness is associated with cerebral flow pulsatility. Arterial stiffness increases following acute resistance exercise (RE. Whether this acute RE-induced vascular stiffening affects cerebral pulsatility remains unknown. Purpose: To investigate the effects of acute RE on common carotid artery (CCA stiffness and cerebral blood flow velocity (CBFv pulsatility. Methods: Eighteen healthy men (22 ± 1 yr; 23.7 ± 0.5 kg∙m-2 underwent acute RE (5 sets, 5-RM bench press, 5 sets 10-RM bicep curls with 90 s rest intervals or a time control condition (seated rest in a randomized order. CCA stiffness (β-stiffness, Elastic Modulus (Ep and hemodynamics (pulsatility index, forward wave intensity and reflected wave intensity were assessed using a combination of Doppler ultrasound, wave intensity analysis and applanation tonometry at baseline and 3 times post-RE. CBFv pulsatility index was measured with transcranial Doppler at the middle cerebral artery (MCA. Results: CCA β-stiffness, Ep and CCA pulse pressure significantly increased post-RE and remained elevated throughout post-testing (p 0.05. There were significant increases in forward wave intensity post-RE (p0.05. Conclusion: Although acute RE increases CCA stiffness and pressure pulsatility, it may not affect CCA or MCA flow pulsatility. Increases in pressure pulsatility may be due to increased forward wave intensity and not pressure from wave reflections.

  5. Post-operative assessment of perfusion of Deep Inferior Epigastric Perforator (DIEP) free flaps via Pulsatility Index (PI) using a portable colour Doppler sonogram device.

    Science.gov (United States)

    Arya, Reza; Griffiths, Louisa; Figus, Andrea; King, David; Ramakrishnan, Venkat; Griffiths, Matthew

    2013-07-01

    PI as an independent indicator of resistance to flow is a widely-accepted alternative index to measurement of flow volume in vessels. This study aimed to determine the normal values and chronological trend of PI of abdominal wall free flaps in breast reconstruction and to revalidate its clinical relevance in post-operative monitoring of these flaps. 47 patients with breast reconstruction using DIEP, MS-TRAM and bi-pedicled DIEP flaps were assessed for PI of the supplying perforator vessels using a hand-held colour Doppler ultrasound device over 6 post-operative days. Triplicate measurements were obtained by one operator once daily concurrently with haemodynamic parameters. DIEP flaps demonstrate a descending trend of PI and resistance to blood flow post-operatively (p=0.005) similar to non-perforator free flaps. MS-TRAM flaps show higher initial PI values and vascular resistance compared to DIEP flaps (p=0.038). PI values show no correlation with haemodynamic parameters (r=0.2, n=38). Flaps with venous insufficiency demonstrate significantly higher values of PI (p=0.03). PI is an objective, non-invasive, efficient, easy-to-measure, reproducible and quickly-responsive indicator of perfusion of DIEP flaps. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Surface obstacles in pulsatile flow

    Science.gov (United States)

    Carr, Ian A.; Plesniak, Michael W.

    2017-11-01

    Flows past obstacles mounted on flat surfaces have been widely studied due to their ubiquity in nature and engineering. For nearly all of these studies, the freestream flow over the obstacle was steady, i.e., constant velocity, unidirectional flow. Unsteady, pulsatile flows occur frequently in biology, geophysics, biomedical engineering, etc. Our study is aimed at extending the comprehensive knowledge base that exists for steady flows to considerably more complex pulsatile flows. Characterizing the vortex and wake dynamics of flows around surface obstacles embedded in pulsatile flows can provide insights into the underlying physics in all wake and junction flows. In this study, we experimentally investigate the wake of two canonical obstacles: a cube and a circular cylinder with an aspect ratio of unity. Our previous studies of a surface-mounted hemisphere in pulsatile flow are used as a baseline for these two new, more complex geometries. Phase-averaged PIV and hot-wire anemometry are used to characterize the dynamics of coherent structures in the wake and at the windward junction of the obstacles. Complex physics occur during the deceleration phase of the pulsatile inflow. We propose a framework for understanding these physics based on self-induced vortex propagation, similar to the phenomena exhibited by vortex rings.

  7. Estimation of abnormal temperature effects on elderly mortality in South Korea using the temperature deviation index

    Science.gov (United States)

    Choi, Giehae; Bae, Hyun-Joo; Lim, Youn-Hee

    2017-07-01

    Recent studies have revealed that the effect of temperature on mortality has changed over time. One of the major contributors to the changes is adaptation. We aimed to understand the relationship between elderly mortality and temperature anomaly using the temperature deviation index (TDI), which considers exposure history. Summertime (May to September) mortality data from 1996 to 2014 and meteorological data from 1971 to 2014 were obtained for 16 regions covering South Korea. The TDI was defined as the target day's temperature abnormality compared to previous 25 years' apparent temperature (AT). The relationship between the TDI and elderly mortality for each region was examined by generalized linear modeling with Poisson distribution. Pooled estimates were computed to yield a national effect estimate. Stratified analyses were performed using the percentiles of AT and TDI. Most regions showed positive linear associations, and the associations ranged from 0.4 to 4.3% increase per unit increase of the TDI. In the pooled analyses, a unit increase of the TDI was associated with a 1.4% increase (95% confidence interval [CI] 0.93-1.87) in elderly mortality. In the stratified analysis, the relationship between the TDI and elderly mortality was significant at or above the 75th percentile of AT (1.32% increase; 95% CI 0.47-2.22). We suggest a positive association between the TDI and elderly mortality in South Korea. The association observed particularly in the highest percentile of AT in the stratified analysis suggests independent effects of temperature anomaly in addition to those of absolute AT.

  8. Estimation of abnormal temperature effects on elderly mortality in South Korea using the temperature deviation index.

    Science.gov (United States)

    Choi, Giehae; Bae, Hyun-Joo; Lim, Youn-Hee

    2017-07-01

    Recent studies have revealed that the effect of temperature on mortality has changed over time. One of the major contributors to the changes is adaptation. We aimed to understand the relationship between elderly mortality and temperature anomaly using the temperature deviation index (TDI), which considers exposure history. Summertime (May to September) mortality data from 1996 to 2014 and meteorological data from 1971 to 2014 were obtained for 16 regions covering South Korea. The TDI was defined as the target day's temperature abnormality compared to previous 25 years' apparent temperature (AT). The relationship between the TDI and elderly mortality for each region was examined by generalized linear modeling with Poisson distribution. Pooled estimates were computed to yield a national effect estimate. Stratified analyses were performed using the percentiles of AT and TDI. Most regions showed positive linear associations, and the associations ranged from 0.4 to 4.3% increase per unit increase of the TDI. In the pooled analyses, a unit increase of the TDI was associated with a 1.4% increase (95% confidence interval [CI] 0.93-1.87) in elderly mortality. In the stratified analysis, the relationship between the TDI and elderly mortality was significant at or above the 75th percentile of AT (1.32% increase; 95% CI 0.47-2.22). We suggest a positive association between the TDI and elderly mortality in South Korea. The association observed particularly in the highest percentile of AT in the stratified analysis suggests independent effects of temperature anomaly in addition to those of absolute AT.

  9. Surface obstacles in pulsatile flow

    Science.gov (United States)

    Carr, Ian A.; Plesniak, Michael W.

    2016-11-01

    Flows past obstacles mounted on flat surfaces have been widely studied due to their ubiquity in nature and engineering. For nearly all of these studies, the freestream flow over the obstacle was steady, i.e. constant velocity unidirectional flow. Unsteady, pulsatile flows occur frequently in biology, geophysics, biomedical engineering, etc. Our study is aimed at extending the comprehensive knowledge base that exists for steady flows to considerably more complex pulsatile flows. Beyond the important practical applications, characterizing the vortex and wake dynamics of flows around surface obstacles embedded in pulsatile flows can provide insights into the underlying physics in all wake and junction flows. In this study, we experimentally investigated the wake of four canonical surface obstacles: hemisphere, cube, and circular cylinders with aspect ratio of 1:1 and 2:1. Phase-averaged PIV and hot-wire anemometry are used to characterize the dynamics of coherent structures in the wake and at the windward junction of the obstacles. Complex physics occur during the deceleration phase of the pulsatile inflow. We propose a framework for understanding these physics based on self-induced vortex propagation, similar to the phenomena exhibited by vortex rings. This material is based in part upon work supported by the National Science Foundation under Grant Number CBET-1236351, and GW Centeor Biomimetics and Bioinspired Engineering (COBRE).

  10. Distinct trends of pulsatility found at the necks of ruptured and unruptured aneurysms.

    Science.gov (United States)

    Patti, Jordan; Viñuela, Fernando; Chien, Aichi

    2014-03-01

    Aneurysm hemodynamics has been shown to be an important factor in aneurysm growth and rupture. Although pulsatility is essential for blood flow and vascular wall function, studies of pulsatile flow properties in brain aneurysm disease are limited. To investigate differences in pulsatility within a group of ruptured and unruptured aneurysms by implementing patient-specific pulsatile flow simulation. 41 of 311 internal carotid artery aneurysms were selected from an aneurysm database (29 unruptured and 12 ruptured) and used for patient-specific hemodynamic simulations of pulsatile flow. Flow pulsatility changes in ruptured and unruptured groups were analyzed by comparing different components of blood flow. Pulsatility index (PI) was used to quantify the pulsatility of blood flow in each group at the aneurysm neck, body, dome, and parent artery. Within the parent artery, PI did not significantly differ between ruptured and unruptured groups (0.58). Within unruptured aneurysms, values of PI similar to that of the parent artery were found (0.61). Trends of significantly higher PI (1.99) were found within ruptured aneurysms (p<0.001). These differences were localized at the aneurysm neck, where PI in ruptured (1.93) and unruptured (0.59) aneurysms was significantly different (p<0.001). A trend towards a lower PI, similar to that in the parent artery, was found in unruptured aneurysms, while ruptured aneurysms followed a trend of higher pulsatility. The difference was significant at the aneurysm neck, indicating that pulsatility and this location may be important aspects of aneurysm rupture and a useful predictor of the risk of aneurysm rupture.

  11. Quantitative Index and Abnormal Alarm Strategy Using Sensor-Dependent Vibration Data for Blade Crack Identification in Centrifugal Booster Fans.

    Science.gov (United States)

    Chen, Jinglong; Sun, Hailiang; Wang, Shuai; He, Zhengjia

    2016-05-09

    Centrifugal booster fans are important equipment used to recover blast furnace gas (BFG) for generating electricity, but blade crack faults (BCFs) in centrifugal booster fans can lead to unscheduled breakdowns and potentially serious accidents, so in this work quantitative fault identification and an abnormal alarm strategy based on acquired historical sensor-dependent vibration data is proposed for implementing condition-based maintenance for this type of equipment. Firstly, three group dependent sensors are installed to acquire running condition data. Then a discrete spectrum interpolation method and short time Fourier transform (STFT) are applied to preliminarily identify the running data in the sensor-dependent vibration data. As a result a quantitative identification and abnormal alarm strategy based on compound indexes including the largest Lyapunov exponent and relative energy ratio at the second harmonic frequency component is proposed. Then for validation the proposed blade crack quantitative identification and abnormality alarm strategy is applied to analyze acquired experimental data for centrifugal booster fans and it has successfully identified incipient blade crack faults. In addition, the related mathematical modelling work is also introduced to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection.

  12. Quantitative Index and Abnormal Alarm Strategy Using Sensor-Dependent Vibration Data for Blade Crack Identification in Centrifugal Booster Fans

    Directory of Open Access Journals (Sweden)

    Jinglong Chen

    2016-05-01

    Full Text Available Centrifugal booster fans are important equipment used to recover blast furnace gas (BFG for generating electricity, but blade crack faults (BCFs in centrifugal booster fans can lead to unscheduled breakdowns and potentially serious accidents, so in this work quantitative fault identification and an abnormal alarm strategy based on acquired historical sensor-dependent vibration data is proposed for implementing condition-based maintenance for this type of equipment. Firstly, three group dependent sensors are installed to acquire running condition data. Then a discrete spectrum interpolation method and short time Fourier transform (STFT are applied to preliminarily identify the running data in the sensor-dependent vibration data. As a result a quantitative identification and abnormal alarm strategy based on compound indexes including the largest Lyapunov exponent and relative energy ratio at the second harmonic frequency component is proposed. Then for validation the proposed blade crack quantitative identification and abnormality alarm strategy is applied to analyze acquired experimental data for centrifugal booster fans and it has successfully identified incipient blade crack faults. In addition, the related mathematical modelling work is also introduced to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection.

  13. Simultaneous retention index analysis of urinary amino acids and carboxylic acids for graphic recognition of abnormal state.

    Science.gov (United States)

    Paik, Man-Jeong; Lee, Hong-Jin; Kim, Kyoung-Rae

    2005-07-05

    Simultaneous profiling analysis of urinary amino acids (AAs) and carboxylic acids (CAs) was combined with retention index (I) analysis for graphic recognition of abnormal metabolic state. The temperature-programmed I values of the AA and CA standards measured as ethoxycarbonyl (EOC)/methoxime (MO)/tert-butyldimethylsilyl (TBDMS) derivatives were used as the reference I values. Urine samples were subjected to the sequential EOC, MO and TBDMS reactions for the analysis by gas chromatography (GC) and GC-mass spectrometry. The complex GC profiles were then transformed into their respective I patterns in bar graphic forms by plotting the normalized peak area ratios (%) of the identified AAs and CAs against their reference I values as the identification numbers. When the present method was applied to infant urine specimens from normal controls and patients with inherited metabolic diseases such as phenylketonuria, maple syrup urine disease, methylmalonic aciduria or isovaleric aciduria, each I pattern of bar graph more distinctly displayed quantitative abundances of urinary AAs and CAs in qualitative I scale, thus allowing graphic discrimination between normal and abnormal states.

  14. Occupational coke oven emissions exposure and risk of abnormal liver function: modifications of body mass index and hepatitis virus infection

    Energy Technology Data Exchange (ETDEWEB)

    Y. Hu; B. Chen; J. Qian; L. Jin; T. Jin; D. Lu [Fudan University, Shanghai (China). Department of Occupational and Environmental Health

    2010-03-15

    Occupational coke oven emissions (COEs) have been considered an important health issue. However, there are no conclusive data on human hepatic injury due to COE exposure. The association of COE exposure with liver function was explored and the effects of modification of potential non-occupational factors were assessed. 705 coke oven workers and 247 referents were investigated. Individual cumulative COE exposure was quantitatively estimated. Serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), {gamma}-glutamyl transferase, alkaline phosphatase, hepatitis B surface antigen and anti-hepatitis C antibody were measured. Among those with high COE exposure, the adjusted ORs of abnormal ALT and AST were 5.23 (95% CI 2.66 to 10.27) and 1.95 (95% CI 1.18 to 3.52), respectively. Overweight individuals (body mass index (BMI) {>=}25 kg/m{sup 2}) with high COE exposure had elevated risks of abnormal ALT (adjusted OR 23.93, 95% CI 8.73 to 65.62) and AST (adjusted OR 5.18, 95% CI 2.32 to 11.58). Risk of liver damage in hepatitis B virus- or hepatitis C virus-positive individuals with COE exposure was also elevated. Long-term exposure to COE increases the risk of liver dysfunction, which is more prominent among those with higher BMI and hepatitis virus infection. The risk assessment of liver damage associated with COE exposure should take BMI and hepatitis virus infection into consideration.

  15. Evaluation of chromosomal abnormalities by clg-FISH and association with proliferative and apoptotic indexes in multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Linardi, C.C.G.; Martinez, G.; Velloso, E.D.R.P.; Leal, A.M.; Kumeda, C.A.; Buccheri, V. [Disciplina de Hematologia e Hemoterapia, Departamento de Clínica Médica, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Azevedo, R.S. [Departamento de Patologia, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Peliçario, L.M.; Dorlhiac-Llacer, P. [Disciplina de Hematologia e Hemoterapia, Departamento de Clínica Médica, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2012-08-24

    Eighty-six newly diagnosed multiple myeloma (MM) patients from a public hospital of São Paulo (Brazil) were evaluated by cIg-FISH for the presence of del(13)(q14), t(4;14)(p16.3;q32) and del(17)(p13). These abnormalities were observed in 46.5, 9.3, and 7.0% of the patients, respectively. In order to identify the possible role of del(13)(q14) in the physiopathology of MM, we investigated the association between this abnormality and the proliferative and apoptotic indexes of plasma cells. When cases demonstrating t(4;14)(p16.3;q32) and del(17)(p13) were excluded from the analysis, we observed a trend towards a positive correlation between the proportion of cells carrying del(13)(q14) and plasma cell proliferation, determined by Ki-67 expression (r = 0.23, P = 0.06). On the other hand, no correlation between the proportion of cells carrying del(13)(q14) and apoptosis, determined by annexin-V staining, was detected (r = 0.05, P = 0.69). In general, patients carrying del(13)(q14) did not have lower survival than patients without del(13)(q14) (P = 0.15), but patients with more than 80% of cells carrying del(13)(q14) showed a lower overall survival (P = 0.033). These results suggest that, when del(13)(q14) is observed in a high proportion of malignant cells, it may have a role in determining MM prognosis. Another finding was a statistically significant lower overall survival of patients with t(4;14)(p16.3;q32) (P = 0.026). In the present study, almost half the patients with t(4;14)(p16.3;q32) died just after diagnosis, before starting treatment. This fact suggests that, in São Paulo, there may be even more patients with this chromosomal abnormality, but they probably die before being diagnosed due to unfavorable socioeconomic conditions. This could explain the low prevalence of this chromosomal abnormality observed in the present study.

  16. 21 CFR 870.4320 - Cardiopulmonary bypass pulsatile flow generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass pulsatile flow generator... Cardiopulmonary bypass pulsatile flow generator. (a) Identification. A cardiopulmonary bypass pulsatile flow generator is an electrically and pneumatically operated device used to create pulsatile blood flow. The...

  17. [Values of the sperm deformity index, acrosome abnormity rate, and sperm DNA fragmentation index of optimized sperm in predicting IVF fertilization failure].

    Science.gov (United States)

    Jiang, Wei-jie; Jin, Fan; Zhou, Li-ming

    2016-02-01

    To investigate the values of the sperm deformity index (SDI), acrosome abnormity rate (AAR), and DNA fragmentation index (DFI) of optimized sperm in the prediction of fertilization failure (fertilization rate fertilization (IVF). We selected 695 cycles of conventional IVF for pure oviductal infertility in this study, including 603 cycles of normal fertilization and 92 cycles of fertilization failure. On the day of oocyte retrieval, we examined sperm morphology, acrosome morphology, and DNA fragmentation using the Diff-Quik, PSA-FITC and SCD methods. We established the joint predictor (JP) by logistic equation and analyzed the values of different parameters in predicting fertilization failure with the receiver operating characteristic (ROC) curve. The fertilization rate was negatively correlated with SDI (r = - 0.07; P = 0.03), AAR (r = -0.49; P fertilization group were 1.24 ± 0.20, (7.75 ± 2.28)%, and (7.87 ± 3.15)%, and those in the fertilization failure group were 1.42 ± 0.15, (12.02 ± 3.06)%, and (13.32 ± 4.13)%, respectively, all with statistically significant differences between the two groups (P fertilization failure ( OR = 2.68, 14.11, and 3.85; P = 0.01, fertilization failure were approximately 1.45, 10%, and 12%. The SDI, AAR and DFI of optimized sperm are closely associated with the fertilization rate, and all have the value for predicting fertilization failure in IVF. The AAR is more valuable than the other single predictors, but JP is more effective than the AAR.

  18. Investigation of the pulsatile pipe flow

    Czech Academy of Sciences Publication Activity Database

    Adamec, J.; Nožička, J.; Kořenář, Josef

    2000-01-01

    Roč. 18, č. 2 (2000), s. 17-22 ISSN 0392-8764 Institutional research plan: CEZ:AV0Z2060917 Keywords : pulsatile flow * laminar-turbulent transition * reynolds normal stress Subject RIV: BK - Fluid Dynamics

  19. Adverse pregnancy outcomes after abnormal first-trimester screening for aneuploidy.

    Science.gov (United States)

    Goetzl, Laura

    2010-09-01

    Women with abnormal results of first trimester screening but with a normal karyotype are at risk for adverse pregnancy outcomes. A nuchal translucency of greater than 3.5 mm is associated with an increased risk of subsequent pregnancy loss, fetal infection, fetal heart abnormalities, and other structural abnormalities. Abnormal levels of first trimester analytes are also associated with adverse pregnancy outcomes, but the predictive value is less impressive. As a single marker, pregnancy-associated plasma protein (PAPP)-A level less than 1st percentile has a good predictive value for subsequent fetal growth restriction. Women with PAPP-A level less than 5th percentile should undergo subsequent risk assessment with routine maternal serum afetoprotein screening with the possible addition of uterine artery pulsatility index assessment in the midtrimester. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Mechanical buckling of artery under pulsatile pressure.

    Science.gov (United States)

    Liu, Qin; Han, Hai-Chao

    2012-04-30

    Tortuosity that often occurs in carotid and other arteries has been shown to be associated with high blood pressure, atherosclerosis, and other diseases. However the mechanisms of tortuosity development are not clear. Our previous studies have suggested that arteries buckling could be a possible mechanism for the initiation of tortuous shape but artery buckling under pulsatile flow condition has not been fully studied. The objectives of this study were to determine the artery critical buckling pressure under pulsatile pressure both experimentally and theoretically, and to elucidate the relationship of critical pressures under pulsatile flow, steady flow, and static pressure. We first tested the buckling pressures of porcine carotid arteries under these loading conditions, and then proposed a nonlinear elastic artery model to examine the buckling pressures under pulsatile pressure conditions. Experimental results showed that under pulsatile pressure arteries buckled when the peak pressures were approximately equal to the critical buckling pressures under static pressure. This was also confirmed by model simulations at low pulse frequencies. Our results provide an effective tool to predict artery buckling pressure under pulsatile pressure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Abnormal uterine artery Doppler velocimetry predicts adverse outcomes in patients with abnormal analytes.

    Science.gov (United States)

    Roeder, Hilary A; Dejbakhsh, Sheila Z; Parast, Mana M; Laurent, Louise C; Woelkers, Douglas A

    2014-10-01

    Our aim was to determine if uterine artery (UtA) Doppler studies would risk-stratify women with abnormal serum analytes on prenatal genetic screening into those at baseline and increased risk for preeclampsia and small-for-gestational age (SGA). This retrospective cohort study examined outcomes of patients with ⩾one abnormal analyte (PAPP-A3.0, AFP>2.5, inhibin>2.0, or unconjugated estriolUtA pulsatility index (PI). Preeclampsia, preterm preeclampsia, SGA (birthweight (BW) one abnormal analyte, UtA Doppler screening, and delivery outcomes. Twenty-four (18%) had an elevated UtA PI (PI>1.6); preeclampsia occurred in 16 (12%) and 26 (20%) delivered a SGA neonate. Abnormal UtA Doppler PI increased the likelihood of a composite outcome of preeclampsia or SGA from 27% to 71% (LR 6.48 (2.93, 14.30)); a negative UtA Doppler PI reduced the likelihood to 18% (LR 0.57 (0.42, 0.78)). Abnormal UtA Doppler PI increased the likelihood of a more severe composite outcome of preterm preeclampsia or IUGR from 11% to 39% (LR 5.49 (3.03, 9.97)); a negative UtA Doppler study reduced the likelihood to 4% (LR 0.35 (0.16, 0.80)). In patients with abnormal serum analytes, abnormal UtA Doppler PI is significantly associated with preeclampsia or SGA and improves the prediction of these adverse outcomes by 9-15-fold. Providers can incorporate UtA Doppler PI into an abbreviated surveillance regimen; they can be reassured that a normal study markedly decreases the risk of a severe early adverse outcome. Copyright © 2014 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  2. Glucocorticoid pulsatility : implications for brain functioning

    NARCIS (Netherlands)

    Sarabdjitsingh, Ratna Angela

    2010-01-01

    Pronounced ultradian and circadian rhythms in the hormones of the hypothalamic-pituitary-adrenal (HPA) axis (i.e. glucocorticoids), one of the body’s major neuroendocrine axes, were already demonstrated several decades ago. Until now, the clinical relevance of the pulsatile nature of glucocorticoids

  3. Pulsatile Proptosis due to Intraorbital Meningocele

    OpenAIRE

    Rumund, A. van; Verrips, A.; Verhagen, W.I.

    2017-01-01

    We present a case of a 79-year-old man with a non-symptomatic pulsatile proptosis of the left eye. Magnetic resonance imaging revealed a meningocele into the left orbit due to an osseous defect in the orbital roof.

  4. Flow characteristics around a deformable stenosis under pulsatile flow condition

    Science.gov (United States)

    Choi, Woorak; Park, Jun Hong; Byeon, Hyeokjun; Lee, Sang Joon

    2018-01-01

    A specific portion of a vulnerable stenosis is deformed periodically under a pulsatile blood flow condition. Detailed analysis of such deformable stenosis is important because stenotic deformation can increase the likelihood of rupture, which may lead to sudden cardiac death or stroke. Various diagnostic indices have been developed for a nondeformable stenosis by using flow characteristics and resultant pressure drop across the stenosis. However, the effects of the stenotic deformation on the flow characteristics remain poorly understood. In this study, the flows around a deformable stenosis model and two different rigid stenosis models were investigated under a pulsatile flow condition. Particle image velocimetry was employed to measure flow structures around the three stenosis models. The deformable stenosis model was deformed to achieve high geometrical slope and height when the flow rate was increased. The deformation of the stenotic shape enhanced jet deflection toward the opposite vessel wall of the stenosis. The jet deflection in the deformable model increased the rate of jet velocity and turbulent kinetic energy (TKE) production as compared with those in the rigid models. The effect of stenotic deformation on the pulsating waveform related with the pressure drop was analyzed using the TKE production rate. The deformable stenosis model exhibited a phase delay of the peak point in the waveform. These results revealed the potential use of pressure drop waveform as a diagnostic index for deformable stenosis.

  5. Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump.

    Science.gov (United States)

    Wang, Shigang; Rider, Alan R; Kunselman, Allen R; Richardson, J Scott; Dasse, Kurt A; Undar, Akif

    2009-01-01

    The objective of this study was to test different pulsatile flow settings of the PediVAS centrifugal pump to seek an optimum setting for pulsatile flow to achieve better pulsatile energy and minimal backflow. The PediVAS centrifugal pump and the conventional pediatric clinical circuit, including a pediatric membrane oxygenator, arterial filter, arterial cannula, and 1/4 in circuit tubing were used. The circuit was primed with 40% glycerin water mixture. Postcannula pressure was maintained at 40 mm Hg by a Hoffman clamp. The experiment was conducted at 800 ml/min of pump flow with a modified pulsatile flow setting at room temperature. Pump flow and pressure readings at preoxygenator and precannula sites were simultaneously recorded by a data acquisition system. The results showed that backflows appeared at flow rates of 200-800 ml/min (200 ml/min increments) with the default pulsatile flow setting and only at 200 ml/min with the modified pulsatile flow setting. With an increased rotational speed difference ratio and a decreased pulsatile width, the pulsatility increased in terms of surplus hemodynamic energy and total hemodynamic energy at preoxygenator and precannula sites. Backflows seemed at preoxygenator and precannula sites at a 70% of rotational speed difference ratio. The modified pulsatile flow setting was better than the default pulsatile flow setting in respect to pulsatile energy and backflow. The pulsatile width and the rotational speed difference ratio significantly affected pulsatility. The parameter of the rotational speed difference ratio can automatically increase pulsatility with increased rotational speeds. Further studies will be conducted to optimize the pulsatile flow setting of the centrifugal pump.

  6. Chrono pharmacotherapy: A pulsatile Drug Delivery

    Directory of Open Access Journals (Sweden)

    Huma Hameed

    2015-01-01

    Full Text Available Chronopharmacotherapy refers to a treatment in which controlled drug delivery is achieved according to circadian rhythms of disease by enhancing therapeutic outcomes and minimizing side effects. Colon targeting has gained great importance not only for the treatment of local diseases such as Crohn’s disease, inflammatory bowel disease and ulcerative colitis but also very important in systemic delivery of proteins/peptides, antiasthmatic drugs, antidiabetic agents and antihypertensive drugs, which mostly show their efficacy based on circadian rhythms of the body.Colon drug delivery is one of the difficult approaches to achieve the targeted and desired outcomes through pulsatile drug delivery by avoiding dose dumping.The main reasonbehind the use of pulsatile delivery is provision ofconstant drug release where a zero-order release is notpreferred. Chronopharmacotherapy in colon targeting play its role bymany systems such ascapsular systems, pulsatile system and osmotic systems, which are based on use of rupturable membranes and biodegradable polymers.The objective of this review article is to provide latest knowledge about drugs with chrono-pharmacological behavior entails night time dosing specially to the colon.

  7. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Niu, Yantao; Xian, Junfang [Capital Medical University, Department of Radiology, Beijing Tongren Hospital, Beijing (China)

    2016-01-15

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm{sup 2}), less so in PT patients (7.97 ± 5.17 mm{sup 2}). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  8. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    International Nuclear Information System (INIS)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang; Niu, Yantao; Xian, Junfang

    2016-01-01

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm 2 ), less so in PT patients (7.97 ± 5.17 mm 2 ). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  9. Anthropometric indexes outperform bioelectrical impedance analysis-derived estimates of body composition in identification of metabolic abnormalities in morbid obesity.

    Science.gov (United States)

    Perea, Verónica; Jiménez, Amanda; Flores, Lílliam; Ortega, Emilio; Coves, Maria J; Vidal, Josep

    2013-01-01

    The validity of anthropometric indexes in ascertaining the body composition (BC) in morbidly obese (MO) subjects has been questioned. Our objective was to evaluate, in MO subjects, whether bioelectrical impedance analysis (BIA) of BC is more closely associated with the metabolic syndrome (MS) and insulin resistance (IR) than are classic anthropometric measurements. The setting was a university hospital. The association between anthropometric (body mass index, waist circumference [WC]) and BIA (total fat mass [FM] [percentage of FM], truncal FM, android FM) estimates of BC, MS, and IR was evaluated in 784 white MO subjects (212 men and 572 women). BIA estimates were calculated using equations specific for MO subjects developed by our own group and validated against dual energy x-ray absorptiometry. The prevalence of the MS and IR was 78.6% and 88.6%, respectively. The body mass index was greater in women with the MS (P <.001) or IR (P <.001), and the WC was larger in subjects of both genders with the MS or IR (P <.001). Moreover, the WC correlated significantly with all the MS components (P <.05). In contrast, the percentage of FM, truncal FM, and android FM were significantly associated with the MS only in women. Stepwise logistic regression analysis demonstrated the WC as the only significant predictor of the MS or IR (both P <.001). Furthermore, receiver operating curve analysis showed WC was the most accurate BC parameter for the identification of subjects with the MS (area under the curve, WC = .681, P <.001) or IR (area under the curve, WC = .753, P <.001). In MO subjects, the BIA-derived indexes of total and central adiposity were not better predictors of the MS or IR than were traditional anthropometric measurements. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  10. Pulsatility index of renal artery in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Baik, Soon Koo; Kim, Kwan Hyun; Jeong, Yon Soo; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok

    2000-01-01

    As one of non-invasive methods evaluating disorders of renal perfusion using Doppler ultrasonography, PI represents the characteristics of the Doppler waveform more accurately than RI, and even when renal perfusion is severely impaired, objective estimation is possible because of using the mean velocity in its calculation. The purpose of this study is to find out the clinical usefulness of PI for evaluating disorder of renal function in patients with liver cirrhosis. The subjects were 167 patients including 89 of Child A and B groups, 39 of Child C group, and 39 of control group. We compared PI, RI, creatinine, serum renin activity and aldosterone level between each groups, and investigated the relationships of PI with creatinine clearance, serum renin activity, and aldosterone level. Meal PI was 1.00 ± 0.15 in control group, 1.17 ± 0.22 in Child A and B groups, and 1.30 ± 0.28 in Child C group, which showed significant difference between each groups (p<0.05). Also RI, creatinine clearance, serum renin activity and aldosterone level revealed significant difference between each groups (p<0.05). PI showed significant negative relationships with creatinine clearance (p=0.009), serum renin activity (p=0.06), and aldosterone level (p=0.001). Measurement of PI by Doppler ultrasonography is a useful non-invasive method for evaluation renal dysfunction in patients with liver cirrhosis.

  11. Positron emission particle tracking in pulsatile flow

    Science.gov (United States)

    Patel, Nitant; Wiggins, Cody; Ruggles, Arthur

    2017-05-01

    Positron emission particle tracking (PEPT) is increasingly used to understand the flow characteristics in complex systems. This research utilizes PEPT to measure pulsatile flow of frequency 2.1 Hz in an elastic Masterkleer PVC tube of 19 mm inner diameter and 3.2 mm wall thickness. Anion exchange resin beads are labeled with 18F and delivered to a pump driven flow loop with motorized ball valve used to develop the pulsatile flow. Data are collected in the tube with circular cross section, and measurements are also collected with a section of the tube pinched. Nominal flow velocities are near 1 m/s and Reynolds numbers near 20,000. Many thousand PEPT particle traces are collected and synchronized with the flow pulsation. These Lagrangian data are presented as a series of 20 still frames depicting the 3-D velocity field present during each phase of the flow pulsation. Pressure data are also collected to resolve the pressure wave front moving through the open elastic tube at velocity 15.2 m/s.

  12. Pulsatile flow in ventricular catheters for hydrocephalus

    Science.gov (United States)

    Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.

    2017-05-01

    The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.

  13. The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation.

    Science.gov (United States)

    Ahn, Chi Bum; Kang, Yang Jun; Kim, Myoung Gon; Yang, Sung; Lim, Choon Hak; Son, Ho Sung; Kim, Ji Sung; Lee, So Young; Son, Kuk Hui; Sun, Kyung

    2016-06-01

    Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation. Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement. To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous O2 saturation, and lactate were measured. The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used. After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow.

  14. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  15. Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader

    2017-12-01

    The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.

  16. Simulations of pulsatile suspension flow through bileaflet mechanical heart valves to quantify platelet damage

    Science.gov (United States)

    Yun, Brian; Aidun, Cyrus; Yoganathan, Ajit

    2012-11-01

    Studies have shown that high shear stress and long exposure times on platelets have a strong impact on thromboembolic complications in bileaflet mechanical heart valves (BMHVs). This numerical study quantifies the platelet damage incurred in pulsatile flow through various BMHV designs. The lattice-Boltzmann method with external boundary force (LBM-EBF) was implemented to simulate pulsatile flow and capture the dynamics and surface shear stresses of modeled platelets with realistic geometry. The platelets are released in key regions of interest in the geometry as well as at various times of the cardiac cycle. The platelet damage is quantified using a linear shear stress-exposure time blood damage index (BDI) model. The multiscale computational method used to quantitatively measure the BDI during the pulsatile flow has been validated as being able to accurately capture bulk BMHV fluid flow and for accurately quantifying platelet damage in BMHV flows. These simulations will further knowledge of the geometric features and cardiac cycle times that most affect platelet damage. This study will ultimately lead to optimization of BMHV design in order to minimize thromboembolic complications.

  17. Indexed

    CERN Document Server

    Hagy, Jessica

    2008-01-01

    Jessica Hagy is a different kind of thinker. She has an astonishing talent for visualizing relationships, capturing in pictures what is difficult for most of us to express in words. At indexed.blogspot.com, she posts charts, graphs, and Venn diagrams drawn on index cards that reveal in a simple and intuitive way the large and small truths of modern life. Praised throughout the blogosphere as “brilliant,” “incredibly creative,” and “comic genius,” Jessica turns her incisive, deadpan sense of humor on everything from office politics to relationships to religion. With new material along with some of Jessica’s greatest hits, this utterly unique book will thrill readers who demand humor that makes them both laugh and think.

  18. Cerebrovascular pulsatility in patients with sleep-disordered breathing.

    Science.gov (United States)

    Ramos, Alberto R; Cabral, Digna; Lee, David J; Sacco, Ralph L; Rundek, Tatjana

    2013-05-01

    The aim of our study is to determine the association between the pulsatility index (PI), a surrogate of cerebral small vessel disease and sleep-disordered breathing (SDB). We conducted a transcranial Doppler ultrasound (TCD) study of 19 consecutive patients free of stroke and cardiovascular disease, referred for the evaluation of SDB. TCD was performed by a certified technologist. Subsequent polysomnography was performed according to the practice parameters of the American Academy of Sleep Medicine. We evaluated the association between the apnea-hypopnea index (AHI), the oxygen nadir, the blood flow velocities, and the Gosling PI, for the middle cerebral artery. We performed Spearman's rank correlation and nonparametric regression to evaluate the relationship between AHI, oxygen levels, and the PI. Median age was 48 years (range 37-83), with 52 % male sex (n = 10), and median BMI of 29.9 (range 25-40.4). The median AHI was 16.4 (0.2-69). The median PI was 0.97 (0.72-1.89) cm/s. The PI correlated with the AHI (rho = 0.44; p = 0.004) and with age (rho = 0.57; p = 0.001). Nonparametric regression adjusting for age showed a positive association between the AHI and the PI (standardized estimate = 0.88; p = 0.002). There was no relation between the oxygen nadir and the PI. We observed increased PI in patients with SDB during wakefulness. The PI could potentially be an estimate of cerebral small vessel disease in patients with SDB and hence allow evaluating cerebral hemodynamics during wakefulness with a clinically relevant device.

  19. A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system.

    Science.gov (United States)

    Herreros, Jesús; Berjano, Enrique J; Sales-Nebot, Laura; Más, Pedro; Calvo, Irene; Mastrobuoni, Stefano; Mercé, Salvador

    2008-06-01

    Previous studies have demonstrated the potential advantages of pulsatile flow as compared with continuous flow. However, to date, physiologic pumps have been technically complex and their application has therefore remained in the experimental field. We have developed a new type of centrifugal pump, which can provide pulsatile as well as continuous flow. The inner wall of a centrifugal pump is pulsed by means of a flexible membrane, which can be accurately controlled by means of either a hydraulic or pneumatic driver. The aim of this study was to assess the hydraulic behavior of the new pump in terms of surplus hemodynamic energy (SHE). We conducted experiments using a mock circulatory system including a membrane oxygenator. No differences were found in the pressure-flow characteristics between the new pump and a conventional centrifugal pump, suggesting that the inclusion of the flexible membrane does not alter hydraulic performance. The value of SHE rose when systolic volume was increased. However, SHE dropped when the percentage of ejection time was reduced and also when the continuous flow (programmed by the centrifugal console) increased. Mean flow matched well with the continuous flow set by the centrifugal console, that is, the pulsatile component of the flow was exclusively controlled by the pulsatile console, and was therefore independent of the continuous flow programmed by the centrifugal console. The pulsatility of the new pump was approximately 25% of that created with a truly pulsatile pump.

  20. Arduino control of a pulsatile flow rig.

    Science.gov (United States)

    Drost, S; de Kruif, B J; Newport, D

    2018-01-01

    This note describes the design and testing of a programmable pulsatile flow pump using an Arduino micro-controller. The goal of this work is to build a compact and affordable system that can relatively easily be programmed to generate physiological waveforms. The system described here was designed to be used in an in-vitro set-up for vascular access hemodynamics research, and hence incorporates a gear pump that delivers a mean flow of 900 ml/min in a test flow loop, and a peak flow of 1106 ml/min. After a number of simple identification experiments to assess the dynamic behaviour of the system, a feed-forward control routine was implemented. The resulting system was shown to be able to produce the targeted representative waveform with less than 3.6% error. Finally, we outline how to further increase the accuracy of the system, and how to adapt it to specific user needs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Congenital Abnormalities

    Science.gov (United States)

    ... Stages Ages and Stages Prenatal Baby (0-12 mos.) Toddler 1-3yrs. Preschool 3-5yrs Grade School ... Categories of Congenital Abnormalities Chromosome Abnormalities Chromosomes are structures that carry genetic material inherited from one generation ...

  2. Pulsatile insulin secretion, impaired glucose tolerance and type 2 diabetes.

    Science.gov (United States)

    Satin, Leslie S; Butler, Peter C; Ha, Joon; Sherman, Arthur S

    2015-04-01

    Type 2 diabetes (T2DM) results when increases in beta cell function and/or mass cannot compensate for rising insulin resistance. Numerous studies have documented the longitudinal changes in metabolism that occur during the development of glucose intolerance and lead to T2DM. However, the role of changes in insulin secretion, both amount and temporal pattern, has been understudied. Most of the insulin secreted from pancreatic beta cells of the pancreas is released in a pulsatile pattern, which is disrupted in T2DM. Here we review the evidence that changes in beta cell pulsatility occur during the progression from glucose intolerance to T2DM in humans, and contribute significantly to the etiology of the disease. We review the evidence that insulin pulsatility improves the efficacy of secreted insulin on its targets, particularly hepatic glucose production, but also examine evidence that pulsatility alters or is altered by changes in peripheral glucose uptake. Finally, we summarize our current understanding of the biophysical mechanisms responsible for oscillatory insulin secretion. Understanding how insulin pulsatility contributes to normal glucose homeostasis and is altered in metabolic disease states may help improve the treatment of T2DM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Pulsatile insulin secretion, impaired glucose tolerance and type 2 diabetes

    Science.gov (United States)

    Satin, Leslie S.; Butler, Peter C.; Ha, Joon; Sherman, Arthur S.

    2015-01-01

    Type 2 diabetes (T2DM) results when increases in beta cell function and/or mass cannot compensate for rising insulin resistance. Numerous studies have documented the longitudinal changes in metabolism that occur during the development of glucose intolerance and lead to T2DM. However, the role of changes in insulin secretion, both amount and temporal pattern has been understudied. Most of the insulin secreted from pancreatic beta cells of the pancreas is released in a pulsatile pattern, which is disrupted in T2DM. Here we review the evidence that changes in beta cell pulsatility occur during the progression from glucose intolerance to T2DM in humans, and contribute significantly to the etiology of the disease. We review the evidence that insulin pulsatility improves the efficacy of secreted insulin on its targets, particularly hepatic glucose production, but also examine evidence that pulsatility alters or is altered by changes in peripheral glucose uptake. Finally, we summarize our current understanding of the biophysical mechanisms responsible for oscillatory insulin secretion. Understanding how insulin pulsatility contributes to normal glucose homeostasis and is altered in metabolic disease states may help improve the treatment of T2DM. PMID:25637831

  4. Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation.

    Directory of Open Access Journals (Sweden)

    Oleksandr V Popovych

    Full Text Available High-frequency (HF deep brain stimulation (DBS is the gold standard for the treatment of medically refractory movement disorders like Parkinson's disease, essential tremor, and dystonia, with a significant potential for application to other neurological diseases. The standard setup of HF DBS utilizes an open-loop stimulation protocol, where a permanent HF electrical pulse train is administered to the brain target areas irrespectively of the ongoing neuronal dynamics. Recent experimental and clinical studies demonstrate that a closed-loop, adaptive DBS might be superior to the open-loop setup. We here combine the notion of the adaptive high-frequency stimulation approach, that aims at delivering stimulation adapted to the extent of appropriately detected biomarkers, with specifically desynchronizing stimulation protocols. To this end, we extend the delayed feedback stimulation methods, which are intrinsically closed-loop techniques and specifically designed to desynchronize abnormal neuronal synchronization, to pulsatile electrical brain stimulation. We show that permanent pulsatile high-frequency stimulation subjected to an amplitude modulation by linear or nonlinear delayed feedback methods can effectively and robustly desynchronize a STN-GPe network of model neurons and suggest this approach for desynchronizing closed-loop DBS.

  5. Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation.

    Science.gov (United States)

    Popovych, Oleksandr V; Lysyansky, Borys; Rosenblum, Michael; Pikovsky, Arkady; Tass, Peter A

    2017-01-01

    High-frequency (HF) deep brain stimulation (DBS) is the gold standard for the treatment of medically refractory movement disorders like Parkinson's disease, essential tremor, and dystonia, with a significant potential for application to other neurological diseases. The standard setup of HF DBS utilizes an open-loop stimulation protocol, where a permanent HF electrical pulse train is administered to the brain target areas irrespectively of the ongoing neuronal dynamics. Recent experimental and clinical studies demonstrate that a closed-loop, adaptive DBS might be superior to the open-loop setup. We here combine the notion of the adaptive high-frequency stimulation approach, that aims at delivering stimulation adapted to the extent of appropriately detected biomarkers, with specifically desynchronizing stimulation protocols. To this end, we extend the delayed feedback stimulation methods, which are intrinsically closed-loop techniques and specifically designed to desynchronize abnormal neuronal synchronization, to pulsatile electrical brain stimulation. We show that permanent pulsatile high-frequency stimulation subjected to an amplitude modulation by linear or nonlinear delayed feedback methods can effectively and robustly desynchronize a STN-GPe network of model neurons and suggest this approach for desynchronizing closed-loop DBS.

  6. Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation

    Science.gov (United States)

    Lysyansky, Borys; Rosenblum, Michael; Pikovsky, Arkady; Tass, Peter A.

    2017-01-01

    High-frequency (HF) deep brain stimulation (DBS) is the gold standard for the treatment of medically refractory movement disorders like Parkinson’s disease, essential tremor, and dystonia, with a significant potential for application to other neurological diseases. The standard setup of HF DBS utilizes an open-loop stimulation protocol, where a permanent HF electrical pulse train is administered to the brain target areas irrespectively of the ongoing neuronal dynamics. Recent experimental and clinical studies demonstrate that a closed-loop, adaptive DBS might be superior to the open-loop setup. We here combine the notion of the adaptive high-frequency stimulation approach, that aims at delivering stimulation adapted to the extent of appropriately detected biomarkers, with specifically desynchronizing stimulation protocols. To this end, we extend the delayed feedback stimulation methods, which are intrinsically closed-loop techniques and specifically designed to desynchronize abnormal neuronal synchronization, to pulsatile electrical brain stimulation. We show that permanent pulsatile high-frequency stimulation subjected to an amplitude modulation by linear or nonlinear delayed feedback methods can effectively and robustly desynchronize a STN-GPe network of model neurons and suggest this approach for desynchronizing closed-loop DBS. PMID:28273176

  7. Three-dimensional ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

    Science.gov (United States)

    El-Sharkawy, Mohamed; El-Mazny, Akmal; Ramadan, Wafaa; Hatem, Dina; Abdel-Hafiz, Aly; Hammam, Mohamed; Nada, Adel

    2016-03-16

    Ultrasonography has been extensively used in women suspected of having a gynecological malignancy. The aim of this study is to evaluate the efficacy of 3D ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding. This cross-sectional study included 78 premenopausal women with abnormal uterine bleeding scheduled for hysteroscopy and endometrial curettage. The endometrial thickness (ET), uterine artery pulsatility index (PI) and resistance index (RI), and endometrial volume (EV) and 3D power Doppler vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were measured and compared with hysteroscopic and histopathologic findings. The ET (P uterine artery PI and RI and endometrial FI were not significantly different between the two groups. The best marker for discrimination between benign and malignant endometrium was the VI with an area under the ROC curve of 0.88 at a cutoff value of 0.81%. 3D ultrasonography and power Doppler, especially endometrial VI, may be useful for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

  8. Pulsatile flow effects on the hemodynamics of intracranial aneurysms.

    Science.gov (United States)

    Le, Trung B; Borazjani, Iman; Sotiropoulos, Fotis

    2010-11-01

    High-resolution numerical simulations are carried out to systematically investigate the effect of the incoming flow waveform on the hemodynamics and wall shear stress patterns of an anatomic sidewall intracranial aneurysm model. Various wave forms are constructed by appropriately scaling a typical human waveform such that the waveform maximum and time-averaged Reynolds numbers, the Womersley number (α), and the pulsatility index (PI) are systematically varied within the human physiologic range. We show that the waveform PI is the key parameter that governs the vortex dynamics across the aneurysm neck and the flow patterns within the dome. At low PI, the flow in the dome is similar to a driven cavity flow and is characterized by a quasi-stationary shear layer that delineates the parent artery flow from the recirculating flow within the dome. At high PI, on the other hand, the flow is dominated by vortex ring formation, transport across the neck, and impingement and breakdown at the distal wall of the aneurysm dome. We further show that the spatial and temporal characteristics of the wall shear stress field on the aneurysm dome are strongly correlated with the vortex dynamics across the neck. We finally argue that the ratio between the characteristic time scale of transport by the mean flow across the neck and the time scale of vortex ring formation can be used to predict for a given sidewall aneurysm model the critical value of the waveform PI for which the hemodynamics will transition from the cavity mode to the vortex ring mode.

  9. Long-Term Durability Test for the Left Ventricular Assist System EVAHEART under the Physiologic Pulsatile Load.

    Science.gov (United States)

    Kitano, Tomoya; Iwasaki, Kiyotaka

    The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.

  10. Fluid-structure interaction simulation of pulsatile ventricular assist devices

    Science.gov (United States)

    Long, C. C.; Marsden, A. L.; Bazilevs, Y.

    2013-11-01

    In this paper we present a collection of fluid-structure interaction (FSI) computational techniques that enable realistic simulation of pulsatile Ventricular Assist Devices (VADs). The simulations involve dynamic interaction of air, blood, and a thin membrane separating the two fluids. The computational challenges addressed in this work include large, buckling motions of the membrane, the need for periodic remeshing of the fluid mechanics domain, and the necessity to employ tightly coupled FSI solution strategies due to the very strong added mass effect present in the problem. FSI simulation of a pulsatile VAD at realistic operating conditions is presented for the first time. The FSI methods prove to be robust, and may be employed in the assessment of current, and the development of future, pulsatile VAD designs.

  11. Loss of inverse relationship between pulsatile insulin and glucagon secretion in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Menge, Björn A; Grüber, Lena; Jørgensen, Signe M

    2011-01-01

    In patients with type 2 diabetes, glucagon levels are often increased. Furthermore, pulsatile secretion of insulin is disturbed in such patients. Whether pulsatile glucagon secretion is altered in type 2 diabetes is not known.......In patients with type 2 diabetes, glucagon levels are often increased. Furthermore, pulsatile secretion of insulin is disturbed in such patients. Whether pulsatile glucagon secretion is altered in type 2 diabetes is not known....

  12. Pulsatile operation of a continuous-flow right ventricular assist device (RVAD) to improve vascular pulsatility.

    Science.gov (United States)

    Ng, Boon C; Kleinheyer, Matthias; Smith, Peter A; Timms, Daniel; Cohn, William E; Lim, Einly

    2018-01-01

    Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9-15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states.

  13. Generation of tunable and pulsatile concentration gradients via microfluidic network

    KAUST Repository

    Zhou, Bingpu

    2014-06-04

    We demonstrate a compact Polydimethylsiloxane microfluidic chip which can quickly generate ten different chemical concentrations simultaneously. The concentration magnitude of each branch can be flexibly regulated based on the flow rate ratios of the two injecting streams. The temporal/pulsatile concentration gradients are achieved by integrating on-chip pneumatic actuated valves controlled by the external signals. The temporal concentration gradients can also be tuned precisely by varying applied frequency and duty cycle of the trigger signal. It is believed that such microdevice will be potentially used for some application areas of producing stable chemical gradients as well as allowing fast, pulsatile gradient transformation in seconds.

  14. Flush-mounted hot film anemometer accuracy in pulsatile flow.

    Science.gov (United States)

    Nandy, S; Tarbell, J M

    1986-08-01

    The accuracy of a flush-mounted hot film anemometer probe for wall shear stress measurements in physiological pulsatile flows was evaluated in fully developed pulsatile flow in a rigid straight tube. Measured wall shear stress waveform based on steady flow anemometer probe calibrations were compared to theoretical wall shear stress waveforms based on well-established theory and measured flow rate waveforms. The measured and theoretical waveforms were in close agreement during systole (average deviation of 14 percent at peak systole). As expected, agreement was poor during diastole because of flow reversal and diminished frequency response at low shear rate.

  15. Does the location of a vascular loop in the cerebellopontine angle explain pulsatile and non-pulsatile tinnitus?

    Energy Technology Data Exchange (ETDEWEB)

    Nowe, V.; Wang, X.L.; Gielen, J.; Goethem, J.Van; Oezsarlak, Oe.; De Schepper, A.M.; Parizel, P.M. [University of Antwerp, Department of Radiology, Edegem (Belgium); Ridder, D. De [University of Antwerp, Department of Neurosurgery, Edegem (Belgium); Heyning, P.H.Van de [University of Antwerp, Department of Otorhinolaryngology, Edegem (Belgium)

    2004-12-01

    The purpose was to investigate patients with unexplained pulsatile and non-pulsatile tinnitus by means of MR imaging of the cerebellopontine angle (CPA) and to correlate the clinical subtype of tinnitus with the location of a blood vessel (in the internal auditory canal or at the cisternal part of the VIIIth cranial nerve). Clinical presentation of tinnitus and perceptive hearing loss were correlated. In 47 patients with unexplained tinnitus, an MR examination of the CPA was performed. Virtual endoscopy reconstructions were obtained using a 3D axial thin-section high-resolution heavily T2-weighted gradient echo constructive interference in steady state (CISS) data-set. High-resolution T2-weighted CISS images showed a significantly higher number of vascular loops in the internal auditory canal in patients with arterial pulsatile tinnitus compared to patients with non-pulsatile tinnitus (P<0.00001). Virtual endoscopy images were used to investigate vascular contacts at the cisternal part of the VIIIth cranial nerve in patients with low pitch and high pitch non-pulsatile tinnitus. A significantly different distribution of the vascular contacts (P=0.0320) was found. Furthermore, a correlation between the clinical presentation of non-pulsatile tinnitus (high pitch and low pitch) and the perceptive hearing loss was found (P=0.0235). High-resolution heavily T2-weighted CISS images and virtual endoscopy of the CPA can be used to evaluate whether a vascular contact is present in the internal auditory canal or at the cisternal part of the VIIIth cranial nerve and whether the location of the vascular contact correlates with the clinical subtype of tinnitus. Our findings suggest that there is a tonotopical structure of the cisternal part of the VIIIth cranial nerve. A correlation between the clinical presentation of tinnitus and hearing loss was found. (orig.)

  16. Does the location of a vascular loop in the cerebellopontine angle explain pulsatile and non-pulsatile tinnitus?

    International Nuclear Information System (INIS)

    Nowe, V.; Wang, X.L.; Gielen, J.; Goethem, J.Van; Oezsarlak, Oe.; De Schepper, A.M.; Parizel, P.M.; Ridder, D. De; Heyning, P.H.Van de

    2004-01-01

    The purpose was to investigate patients with unexplained pulsatile and non-pulsatile tinnitus by means of MR imaging of the cerebellopontine angle (CPA) and to correlate the clinical subtype of tinnitus with the location of a blood vessel (in the internal auditory canal or at the cisternal part of the VIIIth cranial nerve). Clinical presentation of tinnitus and perceptive hearing loss were correlated. In 47 patients with unexplained tinnitus, an MR examination of the CPA was performed. Virtual endoscopy reconstructions were obtained using a 3D axial thin-section high-resolution heavily T2-weighted gradient echo constructive interference in steady state (CISS) data-set. High-resolution T2-weighted CISS images showed a significantly higher number of vascular loops in the internal auditory canal in patients with arterial pulsatile tinnitus compared to patients with non-pulsatile tinnitus (P<0.00001). Virtual endoscopy images were used to investigate vascular contacts at the cisternal part of the VIIIth cranial nerve in patients with low pitch and high pitch non-pulsatile tinnitus. A significantly different distribution of the vascular contacts (P=0.0320) was found. Furthermore, a correlation between the clinical presentation of non-pulsatile tinnitus (high pitch and low pitch) and the perceptive hearing loss was found (P=0.0235). High-resolution heavily T2-weighted CISS images and virtual endoscopy of the CPA can be used to evaluate whether a vascular contact is present in the internal auditory canal or at the cisternal part of the VIIIth cranial nerve and whether the location of the vascular contact correlates with the clinical subtype of tinnitus. Our findings suggest that there is a tonotopical structure of the cisternal part of the VIIIth cranial nerve. A correlation between the clinical presentation of tinnitus and hearing loss was found. (orig.)

  17. Leaback of Pulsatile Flow of Particle Fluid Suspension Model of ...

    African Journals Online (AJOL)

    Leaback of Pulsatile Flow of Particle Fluid Suspension Model of Blood Under Periodic Body Acceleration. ... The variation in body acceleration amplitude though affects the velocity profile in the capillary tubes, it has no effect on the leakback in the tubes. Leakback is mainly determined by the balance of the viscous drag and ...

  18. Experimental Investigation of Pulsatile Flow in Circular Tubes

    Czech Academy of Sciences Publication Activity Database

    Adamec, J.; Nožička, J.; Hanus, D.; Kořenář, Josef

    2001-01-01

    Roč. 17, č. 5 (2001), s. 1133-1136 ISSN 0748-4658 Institutional research plan: CEZ:AV0Z2060917 Keywords : pulsatile flow * laminar-turbulent transition * reynolds normal stress Subject RIV: BK - Fluid Dynamics Impact factor: 0.418, year: 2001

  19. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  20. Circadian changes in pulsatile TSH release in primary hypothyroidism

    NARCIS (Netherlands)

    Adriaanse, R.; Brabant, G.; Prank, K.; Endert, E.; Wiersinga, W. M.

    1992-01-01

    We evaluated pulsatile and circadian TSH secretion in primary hypothyroidism. In a prospective study, blood was sampled every 10 minutes during 24 hours for assay of TSH (IRMA). Thyroid hormones and TSH responsiveness to TRH were then measured. Nine patients with overt primary hypothyroidism, seven

  1. Meiotic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    Chapter 19, describes meiotic abnormalities. These include nondisjunction of autosomes and sex chromosomes, genetic and environmental causes of nondisjunction, misdivision of the centromere, chromosomally abnormal human sperm, male infertility, parental age, and origin of diploid gametes. 57 refs., 2 figs., 1 tab.

  2. Nonlinear analysis and prediction of pulsatile hormone secretion

    Energy Technology Data Exchange (ETDEWEB)

    Prank, K. [Abteilung Klinische Endokrinologie, Medizinische Hochschule Hannover, D-30623 Hannover (Germany)]|[Howard Hughes Medical Institute and Computational Neurobiology Laboratory, The Salk Institute, San Diego, California 92186-5800 (United States); Kloppstech, M. [Abteilung Klinische Endokrinologie, Medizinische Hochschule Hannover, D-30623 Hannover (Germany); Nowlan, S.J. [Howard Hughes Medical Institute and Computational Neurobiology Laboratory, The Salk Institute, San Diego, California 92186-5800 (United States); Harms, H.M.; Brabant, G.; Hesch, R. [Abteilung Klinische Endokrinologie, Medizinische Hochschule Hannover, D-30623 Hannover (Germany); Sejnowski, T.J. [Howard Hughes Medical Institute and Computational Neurobiology Laboratory, The Salk Institute, San Diego, California 92186-5800 (United States)

    1996-06-01

    Pulsatile hormone secretion is observed in almost every hormonal system. The frequency of episodic hormone release ranges from approximately 10 to 100 pulses in 24 hours. This temporal mode of secretion is an important feature of intercellular information transfer in addition to a dose-response dependent regulation. It has been demonstrated in a number of experiments that changes in the temporal pattern of pulsatile hormone secretion specifically regulate cellular and organ function and structure. Recent evidence links osteoporosis, a disease characterized by loss of bone mass and structure, to changes in the dynamics of pulsatile parathyroid hormone (PTH) secretion. In our study we applied nonlinear and linear time series prediction to characterize the secretory dynamics of PTH in both healthy human subjects and patients with osteoporosis. Osteoporotic patients appear to lack periods of high predictability found in normal humans. In contrast to patients with osteoporosis patients with hyperparathyroidism, a condition which despite sometimes reduced bone mass has a preserved bone architecture, show periods of high predictability of PTH secretion. Using stochastic surrogate data sets which match certain statistical properties of the original time series significant nonlinear determinism could be found for the PTH time series of a group of healthy subjects. Using classical nonlinear analytical techniques we could demonstrate that the irregular pattern of pulsatile PTH secretion in healthy men exhibits characteristics of deterministic chaos. Pulsatile secretion of PTH in healthy subjects seems to be a first example of nonlinear determinism in an apparently irregular hormonal rhythm in human physiology. {copyright} {ital 1996 American Institute of Physics.}

  3. Walking abnormalities

    Science.gov (United States)

    ... include: Arthritis of the leg or foot joints Conversion disorder (a mental disorder) Foot problems (such as a ... injuries. For an abnormal gait that occurs with conversion disorder, counseling and support from family members are strongly ...

  4. What is the definition of pulsatile umbilical venous flow in twin-twin transfusion syndrome?

    Science.gov (United States)

    Russell, Zoi; Quintero, Rubén A; Kontopoulos, Eftichia V

    2008-12-01

    The aim of the study was to derive an objective definition of pulsatile umbilical venous flow (PUVF). Pulsed Doppler waveform analysis of the umbilical vein was performed in stages III and IV twin-twin transfusion syndrome (TTTS) patients. In patients with PUVF, the umbilical vein maximum (Vmax) and the umbilical vein minimum velocity (Vmin) and the resistance index for the umbilical vein (UVRI) = (100 x [Vmax - Vmin]/Vmax) were assessed. PUVF was noted in 130 of 226 stages III and IV TTTS patients. Digital images were available for analysis in 65 of 130 patients (50%). The minimum UVRI associated with PUVF was 16% for stages III and IV TTTS. There was a trend for increasing UVRI with stage (P = .052). Stage IV patients were more likely to have an UVRI greater than 30% (P = .02). PUVF can be defined as an UVRI greater than 15%. A scale definition of PUVF may further facilitate assessment of the degree of fetal hemodynamic compromise.

  5. Pulsatile blood flow, shear force, energy dissipation and Murray's Law

    Directory of Open Access Journals (Sweden)

    Bengtsson Hans-Uno

    2006-08-01

    Full Text Available Abstract Background Murray's Law states that, when a parent blood vessel branches into daughter vessels, the cube of the radius of the parent vessel is equal to the sum of the cubes of the radii of daughter blood vessels. Murray derived this law by defining a cost function that is the sum of the energy cost of the blood in a vessel and the energy cost of pumping blood through the vessel. The cost is minimized when vessel radii are consistent with Murray's Law. This law has also been derived from the hypothesis that the shear force of moving blood on the inner walls of vessels is constant throughout the vascular system. However, this derivation, like Murray's earlier derivation, is based on the assumption of constant blood flow. Methods To determine the implications of the constant shear force hypothesis and to extend Murray's energy cost minimization to the pulsatile arterial system, a model of pulsatile flow in an elastic tube is analyzed. A new and exact solution for flow velocity, blood flow rate and shear force is derived. Results For medium and small arteries with pulsatile flow, Murray's energy minimization leads to Murray's Law. Furthermore, the hypothesis that the maximum shear force during the cycle of pulsatile flow is constant throughout the arterial system implies that Murray's Law is approximately true. The approximation is good for all but the largest vessels (aorta and its major branches of the arterial system. Conclusion A cellular mechanism that senses shear force at the inner wall of a blood vessel and triggers remodeling that increases the circumference of the wall when a shear force threshold is exceeded would result in the observed scaling of vessel radii described by Murray's Law.

  6. Pulsatile fluidic pump demonstration and predictive model application

    International Nuclear Information System (INIS)

    Morgan, J.G.; Holland, W.D.

    1986-04-01

    Pulsatile fluidic pumps were developed as a remotely controlled method of transferring or mixing feed solutions. A test in the Integrated Equipment Test facility demonstrated the performance of a critically safe geometry pump suitable for use in a 0.1-ton/d heavy metal (HM) fuel reprocessing plant. A predictive model was developed to calculate output flows under a wide range of external system conditions. Predictive and experimental flow rates are compared for both submerged and unsubmerged fluidic pump cases

  7. Pulsatility role in cylinder flow dynamics at low Reynolds number

    KAUST Repository

    Qamar, Adnan

    2012-01-01

    We present dynamics of pulsatile flow past a stationary cylinder characterized by three non-dimensional parameters: the Reynolds number (Re), non-dimensional amplitude (A) of the pulsatile flow velocity, and Keulegan-Carpenter number (KC = Uo/Dωc). This work is motivated by the development of total artificial lungs (TAL) device, which is envisioned to provide ambulatory support to patients. Results are presented for 0.2 ≤ A ≤ 0.6 and 0.57 ≤ KC ≤ 2 at Re = 5 and 10, which correspond to the operating range of TAL. Two distinct fluid regimes are identified. In both regimes, the size of the separated zone is much greater than the uniform flow case, the onset of separation is function of KC, and the separation vortex collapses rapidly during the last fraction of the pulsatile cycle. The vortex size is independent of KC, but with an exponential dependency on A. In regime I, the separation point remains attached to the cylinder surface. In regime II, the separation point migrates upstream of the cylinder. Two distinct vortex collapse mechanisms are observed. For A < 0.4 and all KC and Re values, collapse occurs on the cylinder surface, whereas for A > 0.4 the separation vortex detaches from the cylinder surface and collapses at a certain distance downstream of the cylinder. The average drag coefficient is found to be independent of A and KC, and depends only on Re. However, for A > 0.4, for a fraction of the pulsatile cycle, the instantaneous drag coefficient is negative indicating a thrust production. © 2012 American Institute of Physics.

  8. Coupling the Guyton model to pulsatile ventricles using a multiresolution modelling environment.

    OpenAIRE

    Le Rolle, Virginie; Ojeda, David; Madeleine, Raphael; Carrault, Guy; Hernández, Alfredo,

    2010-01-01

    International audience; In this paper, we propose the substitution of the original, non-pulsatile cardiac sub-model of the Guyton model by an elastance-based pulsatile model of the heart, including interventricular interaction through the septum. Parameters of this cardiac model were identified by comparing the simulations obtained from the original Guyton model with those obtained from the proposed integrated, pulsatile model, during the 5 minutes simulation of a sudden severe muscle exercis...

  9. Luteinizing hormone pulsatility in females following radiation therapy for central nervous system malignancies

    International Nuclear Information System (INIS)

    Brasacchio, R.A.; Constine, L.S.; Woolf, P.; Raubertas, R.F.; Veldhuis, J.D.; Muhs, A.G.

    1997-01-01

    Purpose: Females incidentally irradiated to the hypothalamic-pituitary axis (H/P-A) during radiation therapy (RT) for brain tumors may become oligoamenorrheic. We previously demonstrated that these women are hypoestrogenemic but frequently have near normal or only moderately decreased basal luteinizing hormone (LH) levels and maintain appropriate peak pituitary responses to exogenous gonadotropin releasing hormone (GnRH). We postulated that hypothalamic injury resulting in abnormal LH pulsatility could explain this complex of findings. This investigation intended to characterize this hypothalamic injury and test two potentially corrective pharmacologic interventions. Catecholamines (specifically dopamine) and opiates are known to suppress pituitary LH release through inhibition of the pituitary gonadotropes or of the GnRH neuronal terminals in the hypothalamus. Radiation-induced dysfunction of the catecholaminergic or opiate control mechanisms might translate into an increase in dopamine or opiate release or receptor responsiveness, which in turn would inhibit pulsatile gonadotropin secretion, leading to reduced LH pulsatility and to gonadal dysfunction. We therefore determined the pattern of LH release in normal controls and in patients, at baseline as well as after administration of the dopamine receptor antagonist metoclopramide (MCP), and the opiate-receptor antagonist naloxone (NAL). Methods: Patient eligibility criteria included RT to the H/P-A for a non-H/P-A CNS tumor, usually astrocytoma, with subsequent hypoestrogenemia and oligo-amenorrhea. Patients and normal volunteers were studied first under control conditions and then using MCP and NAL in a randomized cross-over manner at monthly intervals. Serum samples for LH determination were taken every 10 minutes for 12 hours during an overnight hospital stay. MCP (10 mg) was administered as an IV bolus every 4.5 hours, and NAL was administered as a continuous infusion (1.6 mg/hour). The following morning each

  10. Detection of Hb Rothschild HBB: c.[112T>A or 112T>C], Through High Index of Suspicion on Abnormal Pulse Oximetry.

    Science.gov (United States)

    Alli, Nazeer A; Wessels, Piet; Rampersad, Narisha; Clark, Barnaby E; Thein, Swee Lay

    2017-03-01

    We describe a case with a low oxygen affinity hemoglobin (Hb) variant who presented with cyanosis in the absence of cardiopulmonary disease. The patient, a 27-year-old pregnant female (P1G2), complained of a productive cough and bluish discoloration of the lips that started 3 days prior to seeking attention. She had no previous episodes and has generally been in good health. A positive family history of cyanosis was obtained in one sibling. Systematic examination, notably the cardiorespiratory system, revealed no abnormalities. The arterial Hb oxygen saturation (SpO 2 ) on pulse oximetry was 81.0% and Hb separation studies revealed an Hb variant identified as Hb Rothschild [β37(C3)Trp→Arg] (HBB: c.[112 T>A or 112 T>C]) by gene sequencing. The amino acid substitution (Trp→Arg) is an important contact point at the α1β2 interface and favors a T-quaternary state of the Hb tetramer. This leads to a low oxygen affinity state, which results in premature release of oxygen and drop in oxygen saturation. In the absence of cardiopulmonary disease, a decreased oxygen saturation reading, with or without cyanosis, should arouse suspicion for a possible dysHb.

  11. An Optimization Formulation for Characterization of Pulsatile Cortisol Secretion

    Directory of Open Access Journals (Sweden)

    Rose Taj Faghih

    2015-08-01

    Full Text Available Cortisol is released to relay information to cells to regulate metabolism and reaction to stress and inflammation. In particular, cortisol is released in the form of pulsatile signals. This low-energy method of signaling seems to be more efficient than continuous signaling. We hypothesize that there is a controller in the anterior pituitary that leads to pulsatile release of cortisol, and propose a mathematical formulation for such controller, which leads to impulse control as opposed to continuous control. We postulate that this controller is minimizing the number of secretory events that result in cortisol secretion, which is a way of minimizing the energy required for cortisol secretion; this controller maintains the blood cortisol levels within a specific circadian range while complying with the first order dynamics underlying cortisol secretion. We use an l0-norm cost function for this controller, and solve a reweighed l1-norm minimization algorithm for obtaining the solution to this optimization problem. We use 4 examples to illustrate the performance of this approach: (i a toy problem that achieves impulse control, (ii two examples that achieve physiologically plausible pulsatile cortisol release, (iii an example where the number of pulses is not within the physiologically plausible range for healthy subjects while the cortisol levels are within the desired range. This novel approach results in impulse control where the impulses and the obtained blood cortisol levels have a circadian rhythm and an ultradian rhythm that are in agreement with the known physiology of cortisol secretion. The proposed formulation is a first step in developing intermittent controllers for curing cortisol deficiency. This type of bio-inspired pulse controllers can be employed for designing non-continuous controllers in brain-machine interface design for neuroscience applications.

  12. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    Science.gov (United States)

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  13. Changes in intracranial venous blood flow and pulsatility in Alzheimer's disease: A 4D flow MRI study.

    Science.gov (United States)

    Rivera-Rivera, Leonardo A; Schubert, Tilman; Turski, Patrick; Johnson, Kevin M; Berman, Sara E; Rowley, Howard A; Carlsson, Cynthia M; Johnson, Sterling C; Wieben, Oliver

    2017-06-01

    Cerebral blood flow, arterial pulsation, and vasomotion may be important indicators of cerebrovascular health in aging and diseases of aging such as Alzheimer's disease. Noninvasive markers that assess these characteristics may be helpful in the study of co-occurrence of these diseases and potential additive and interacting effects. In this study, 4D flow MRI was used to measure intra-cranial flow features with cardiac-gated phase contrast MRI in cranial arteries and veins. Mean blood flow and pulsatility index as well as the transit time of the peak flow from the middle cerebral artery to the superior sagittal sinus were measured in a total of 104 subjects comprising of four groups: (a) subjects with Alzheimer's disease, (b) age-matched controls, (c) subjects with mild cognitive impairment, and (d) a group of late middle-aged with parental history of sporadic Alzheimer's disease. The Alzheimer's disease group exhibited: a significant decrease in mean blood flow in the superior sagittal sinus, transverse sinus, middle cerebral artery, and internal carotid arteries; a significant decrease of the peak and end diastolic blood flow in the middle cerebral artery and superior sagittal sinus; a faster transmission of peak flow from the middle cerebral artery to the superior sagittal sinus and increased pulsatility index along the carotid siphon.

  14. Holographic laser Doppler imaging of pulsatile blood flow

    Science.gov (United States)

    Bencteux, Jeffrey; Pagnoux, Pierre; Kostas, Thomas; Bayat, Sam; Atlan, Michael

    2015-06-01

    We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded optical signal was linked to local instantaneous out-of-plane motion of the skin at velocities of a few hundreds of microns per second and compared to blood pulse monitored by plethysmoraphy during an occlusion-reperfusion experiment.

  15. Comparison between induction effect with pulsatile and continuous oxytocin administration on outcomes of pregnancy in the pregnant women referring to Tabriz 29 Bahman hospital in 2006

    Directory of Open Access Journals (Sweden)

    fahimeh Sehhati

    2008-04-01

    Full Text Available Abstract Background: Insufficient uterine activity or hypotonic uterine contraction is a common reason and the cause of abnormal labor progress that can be corrected with oxytocin. Realizing this fact that undue prolongation of labor may contribute to prenatal morbidity has resulted in using oxytocin infusion in different kinds of ineffective uterine contractions. Materials and methods: In this study, one hundred pregnant women in 29 Bahman hospital participated in a quasi-experimental research and were divided randomly into 2 groups of pulsatile induction as well as continuous induction and were compared in terms of pregnancy outcomes including progress of labor, hyperstimulation, mood of delivery, third stage duration, newborn’s Apgar score, and hyperbilirobinemia. Results: There were no significant differences between the two groups in progress of labor, hyperstimulation rate, newborn’s Apgar score, and hyperbilirobinemia (p>0.05 however, significant differences were observed in labor duration (p=0.022, mood of delivery (p=0.008, and dose of oxytocin (p<0.0005. Conclusion: According to the findings of this study, administration of oxytocin with the feedback pulsatile oxytocin system is easier and more physiologic to establish the effective uterine contraction and reduces duration of labor and cesarean section rate. Moreover, the average dose of oxytocin administered is significantly less in the pulsatile induction group.

  16. Pulsatile cardiopulmonary bypass and renal function in elderly patients undergoing aortic valve surgery

    NARCIS (Netherlands)

    Milano, Aldo Domenico; Dodonov, Mikhail; Van Oeveren, Willem; Onorati, Francesco; Gu, Y. John; Tessari, Maddalena; Menon, Tiziano; Gottin, Leonardo; Faggian, Giuseppe

    OBJECTIVES: To evaluate if pulsatile cardiopulmonary bypass (CPB) has any protective influence on renal function in elderly patients undergoing aortic valve replacement (AVR). METHODS: Forty-six patients (>= 75 years old) with aortic valve stenosis underwent AVR with either pulsatile perfusion (PP)

  17. Pulsatile luteinising hormone releasing hormone for ovulation induction in subfertility associated with polycystic ovary syndrome

    NARCIS (Netherlands)

    Bayram, N.; van Wely, M.; Vandekerckhove, P.; Lilford, R.; van der Veen, F.

    2000-01-01

    BACKGROUND: In normal menstrual cycles, gonadotrophin releasing hormone (GnRH) secretion is pulsatile, with intervals of 60-120 minutes in the follicular phase. Treatment with pulsatile GnRH infusion by the intra-venous or subcutaneous route using a portable pump has been used successfully in

  18. Pulsatile tinnitus as the presenting symptom in a patient with posterior reversible encephalopathy syndrome.

    Science.gov (United States)

    Mohammed, Hassan; Briggs, Mayen; Phillips, John

    2016-09-01

    We present a case of posterior reversible encephalopathy syndrome (PRES) presenting with pulsatile tinnitus. We highlight the significance of a detailed neurological and cardiovascular assessment including the measurement of blood pressure in patients presenting with pulsatile tinnitus. Case presentation and literature review. One patient with undiagnosed PRES, who presented to our ear, nose and throat surgery department with pulsatile tinnitus is discussed. Symptoms, signs, investigations and treatments are presented. A literature review is also included. Pulsatile tinnitus can be the presenting symptom of neurovascular disorders, some of which might have serious sequelae if not treated promptly. Detailed neurological and cardiovascular history is recommended in addition to radiological investigations in patients presenting with pulsatile tinnitus.

  19. Prediction and control of neural responses to pulsatile electrical stimulation

    Science.gov (United States)

    Campbell, Luke J.; Sly, David James; O'Leary, Stephen John

    2012-04-01

    This paper aims to predict and control the probability of firing of a neuron in response to pulsatile electrical stimulation of the type delivered by neural prostheses such as the cochlear implant, bionic eye or in deep brain stimulation. Using the cochlear implant as a model, we developed an efficient computational model that predicts the responses of auditory nerve fibers to electrical stimulation and evaluated the model's accuracy by comparing the model output with pooled responses from a group of guinea pig auditory nerve fibers. It was found that the model accurately predicted the changes in neural firing probability over time to constant and variable amplitude electrical pulse trains, including speech-derived signals, delivered at rates up to 889 pulses s-1. A simplified version of the model that did not incorporate adaptation was used to adaptively predict, within its limitations, the pulsatile electrical stimulus required to cause a desired response from neurons up to 250 pulses s-1. Future stimulation strategies for cochlear implants and other neural prostheses may be enhanced using similar models that account for the way that neural responses are altered by previous stimulation.

  20. Growth hormone pulsatility profile characteristics following acute heavy resistance exercise.

    Science.gov (United States)

    Nindl, B C; Hymer, W C; Deaver, D R; Kraemer, W J

    2001-07-01

    This investigation examined the hypothesis that acute heavy resistance exercise (AHRE) would increase overnight concentrations of circulating human growth hormone (hGH). Ten men (22 +/- 1 yr, 177 +/- 2 cm, 79 +/- 3 kg, 11 +/- 1% body fat) underwent two overnight blood draws sampled every 10 min from 1700 to 0600: a control and an AHRE condition. The AHRE was conducted from 1500 to 1700 and was a high-volume, multiset exercise bout. Three different immunoassays measured hGH concentrations: the Nichols immunoradiometric assay (Nichols IRMA), National Institute of Diabetes and Digestive and Kidney Diseases radioimmunoassay (NIDDK RIA), and the Diagnostic Systems Laboratory immunofunctional assay (DSL IFA). The Pulsar peak detection system was used to evaluate the pulsatility profile characteristics of hGH. Maximum hGH was lower in the exercise (10.7 microg/l) vs. the control (15.4 microg/l) condition. Mean pulse amplitude was lower in the exercise vs. control condition when measured by the Nichols IRMA and the DSL IFA. A differential pattern of release was also observed after exercise in which hGH was lower in the first half of sleep but higher in the second half. We conclude that AHRE does influence the temporal pattern of overnight hGH pulsatility. Additionally, because of the unique molecular basis of the DSL IFA, this influence does have biological relevance because functionally intact molecules are affected.

  1. Modeling of pulsatile flow-dependent nitric oxide regulation in a realistic microvascular network.

    Science.gov (United States)

    Wang, Ruofan; Pan, Qing; Kuebler, Wolfgang M; Li, John K-J; Pries, Axel R; Ning, Gangmin

    2017-09-01

    Hemodynamic pulsatility has been reported to regulate microcirculatory function. To quantitatively assess the impact of flow pulsatility on the microvasculature, a mathematical model was first developed to simulate the regulation of NO production by pulsatile flow in the microcirculation. Shear stress and pressure pulsatility were selected as regulators of endothelial NO production and NO-dependent vessel dilation as feedback to control microvascular hemodynamics. The model was then applied to a real microvascular network of the rat mesentery consisting of 546 microvessels. As compared to steady flow conditions, pulsatile flow increased the average NO concentration in arterioles from 256.8±93.1nM to 274.8±101.1nM (Pflow as compared to steady flow conditions. Network perfusion and flow heterogeneity were improved under pulsatile flow conditions, and vasodilation within the network was more sensitive to heart rate changes than pulse pressure amplitude. The proposed model simulates the role of flow pulsatility in the regulation of a complex microvascular network in terms of NO concentration and hemodynamics under varied physiological conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Pulsatile haemodynamic parameters are predictors of survival in paediatric pulmonary arterial hypertension

    NARCIS (Netherlands)

    Douwes, Johannes M.; Roofthooft, Marcus T. R.; Bartelds, Beatrijs; Talsma, Melle D.; Hillege, Hans L.; Berger, Rolf M. F.

    2013-01-01

    Background: There is a need for reliable prognostic parameters in pulmonary arterial hypertension (PAH), especially in children. Pulsatile components of the right ventricular afterload, represented by pulmonary arterial compliance (PACi) and pulmonary stroke volume (PSVi), may provide important

  3. Hydrodynamic characteristics of mechanical heart valve prostheses in steady and pulsatile flow

    Czech Academy of Sciences Publication Activity Database

    Klimeš, František; Kořenář, Josef

    2002-01-01

    Roč. 9, č. 4 (2002), s. 249-258 ISSN 1210-2717 Institutional research plan: CEZ:AV0Z2060917 Keywords : mechanical heart valve prostheses * flow visualization- steady and pulsatile flow Subject RIV: BO - Biophysics

  4. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-03-06

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.

  5. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-01-01

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases. PMID:25744850

  6. Right ventricular response to pulsatile load is associated with early right heart failure and mortality after left ventricular assist device.

    Science.gov (United States)

    Grandin, E Wilson; Zamani, Payman; Mazurek, Jeremy A; Troutman, Gregory S; Birati, Edo Y; Vorovich, Esther; Chirinos, Julio A; Tedford, Ryan J; Margulies, Kenneth B; Atluri, Pavan; Rame, J Eduardo

    2017-01-01

    Right ventricular (RV) adaptation to afterload is crucial for patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. We hypothesized that stratifying patients by RV pulsatile load, using pulmonary arterial compliance (PAC), and RV response to load, using the ratio of central venous to pulmonary capillary wedge pressure (CVP:PCWP), would identify patients at high risk for early right heart failure (RHF) and 6-month mortality after cf-LVAD. During the period from January 2008 to June 2014, we identified 151 patients at our center with complete hemodynamics prior to cf-LVAD. Pulsatile load was estimated using PAC indexed to body surface area (BSA), according to the formula: indexed PAC (PACi) = [SV / (PA systolic - PA diastolic )] / BSA, where SV is stroke volume and PA is pulmonary artery. Patients were divided into 4 hemodynamic groups by PACi and CVP:PCWP. RHF was defined as the need for unplanned RVAD, inotropic support ≥14 days or death due to RHF within 14 days. Risk factors for RHF and 6-month mortality were examined using logistic regression and Cox proportional hazards modeling. Sixty-one patients (40.4%) developed RHF and 34 patients (22.5%) died within 6 months. Patients with RHF had lower PACi (0.92 vs 1.17 ml/mm Hg/m 2 , p = 0.008) and higher CVP:PCWP (0.48 vs 0.37, p = 0.001). Higher PACi was associated with reduced risk of RHF (adjusted odds ratio [adj-OR] 0.61, 95% confidence interval [CI] 0.39 to 0.94, p = 0.025) and low PACi with increased risk of 6-month mortality (adjusted hazard ratio [adj-HR] 3.18, 95% CI 1.40 to 7.25, p = 0.006). Compared to patients with low load (high PACi) and adequate right heart response to load (low CVP:PCWP), patients with low PACi and high CVP:PCWP had an increased risk of RHF (OR 4.74, 95% CI 1.23 to 18.24, p = 0.02) and 6-month mortality (HR 8.68, 95% CI 2.79 to 26.99, p < 0.001). A hemodynamic profile combining RV pulsatile load and response to load identifies patients at high

  7. Cerebrovascular blood oxygenation level dependent pulsatility at baseline and following acute exercise among healthy adolescents.

    Science.gov (United States)

    Theyers, Athena E; Goldstein, Benjamin I; Metcalfe, Arron Ws; Robertson, Andrew D; MacIntosh, Bradley J

    2018-01-01

    Arterial stiffness is linked to cerebral small vessel damage and neurodegeneration, but barriers to accessing deep cerebrovascular anatomy limit our ability to assess the brain. This study describes an adaptation of a cardiac-related scrubbing method as a means of generating blood oxygenation level-dependent pulsatility maps based on the cardiac cycle. We examine BOLD pulsatility at rest, based on the non-parametric deviation from null metric, as well as changes following acute physiological stress from 20 min of moderate-intensity cycling in 45 healthy adolescents. We evaluate the influence of repetition time (TR) and echo time (TE) using simulated and multi-echo empirical data, respectively. There were tissue-specific and voxel-wise BOLD pulsatility decreases 20 min following exercise cessation. BOLD pulsatility detection was comparable over a range of TR and TE values when scan volumes were kept constant; however, short TRs (≤500 ms) and TEs (∼14 ms) acquisitions would yield the most efficient detection. Results suggest cardiac-related BOLD pulsatility may represent a robust and easily adopted method of mapping cerebrovascular pulsatility with voxel-wise resolution.

  8. Recent Advancement and Technological Aspects of Pulsatile Drug Delivery System - A Laconic Review.

    Science.gov (United States)

    Pandit, Vinay; Kumar, Ajay; Ashawat, Mahendra S; Verma, Chander P; Kumar, Pravin

    2017-01-01

    Pulsatile drug delivery system (PDDS) shows potential significance in the field of drug delivery to release the maximum amount of drug at a definite site and at specific time. PDDS are mainly time controlled delivery devices having a definite pause period for drug release, which is not affected by acidity, alkalinity, motility and enzymes present in the gastrointestinal tract. Pulsatile medication possess the potential to deliver the drugs in the therapy of diseases where drug dose is essential during sleep, drugs having greater first pass metabolism and absorption at precise location in digestive tract. The review article, discuss the general concepts, marketed formulations and patents or any other recent advancement in pulsatile release technology. It also highlights on diseases requiring therapy by pulsatile release, various researches on herbal pulsatile formulations and quality control aspects of PDDS. Pulsatile medication possess the potential to deliver the drugs in the therapy of diseases where drug dose is essential during sleep, drugs having greater first pass metabolism and absorption at precise location in digestive tract. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. On the quantification and visualization of transient periodic instabilities in pulsatile flows.

    Science.gov (United States)

    Khan, Muhammad Owais; Chnafa, Christophe; Gallo, Diego; Molinari, Filippo; Morbiducci, Umberto; Steinman, David A; Valen-Sendstad, Kristian

    2017-02-08

    Turbulent-like flows without cycle-to-cycle variations are more frequently being reported in studies of cardiovascular flows. The associated stimuli might be of mechanobiological relevance, but how to quantify them objectively is not obvious. Classical Reynolds decomposition, where the flow is separated into mean and fluctuating velocity components, is not applicable as the phase-average is zero. We therefore expanded on established techniques and present the idea, analogous to Reynolds decomposition, to decompose a flow with transient instabilities into low- versus high frequency components, respectively, to discriminate flow instabilities from the underlying cardiac pulsatility. Transient wall shear stress and velocity signals derived from computational fluid dynamic simulations were transferred to the frequency domain. A high-pass filter was applied to subtract the 99% most-energy-containing frequencies, which gave a cut-off frequency of 25Hz. We introduce here the spectral power index, and compute the fluctuating kinetic energy, based on the high-pass filtered velocity components, both being frequency-based operators. The efficacy was evaluated in an aneurysm model for multiple flow rates demonstrating transition to turbulent-like flows. The frequency-based operators were found to better correlate with the qualitatively observed flow instabilities compared to conventional descriptors, like time-averaged wall shear stress or oscillatory shear index. We demonstrate how the high frequencies beyond the physiological range could be analyzed and/or transferred back to the time domain for quantification and visualization purposes. We have introduced general frequency-based operators, easily extendable to other cardiovascular territories based on a posteriori heuristic filtering that allows for separation, isolation, and quantification of cycle-invariant turbulent-like flows. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Abnormal Head Position

    Science.gov (United States)

    ... Frequently Asked Questions Español Condiciones Chinese Conditions Abnormal Head Position En Español Read in Chinese What is an abnormal head posture? An abnormal or compensatory head posture occurs ...

  11. Dying art of a history and physical: pulsatile tinnitus.

    Science.gov (United States)

    Lee, Jonathan; Fekete, Zoltan

    2017-11-27

    Modern medicine often leaves the history and physical by the wayside. Physicians instead skip directly to diagnostic modalities like MRI and angiography. In this case report, we discuss a patient who presented with migraine symptoms. Auscultation revealed signs of pulsatile tinnitus. Further imaging concluded that it was secondary to a type I dural arteriovenous fistula. Thanks to a proper and thorough history and physical, the patient was streamlined into an accurate and efficient work-up leading to symptomatic relief and quality of life improvement. Imaging is a powerful adjunctive technique in modern medicine, but physicians must not rely on machines to diagnose their patients. If this trend continues, it will have a tremendous negative impact on the cost and calibre of healthcare. Our hope is that this case will spread awareness in the medical community, urging physicians to use the lost art of a history and physical. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Pulsatile blood pump with a linear drive actuator.

    Science.gov (United States)

    Fukunaga, Kazuyoshi; Homma, Akihiko; Funakubo, Akio; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Kitamura, Soichiro; Fukui, Yasuhiro

    2007-01-01

    The main purpose of this study was to develop an implantable direct-electromagnetic left ventricular assist system driven by a linear actuator (linear LVAS). The linear LVAS is a pulsatile pump with a pusher plate that is driven directly by a linear oscillatory actuator (LOA) without any movement converters. This prototype pump unit with a LOA was 100 mm in diameter, 50 mm in thickness, and weighed 740 g. The full-fill/full-eject driving method was applied to the control algorithm. In addition, a mechanism to detect and release sucking was realized to overcome this problem that accompanies the active-filling type of VAS. The performance of the linear LVAS was evaluated in a long-term animal experiment using a goat (56 kg). The goat survived for 42 days. The reason why we terminated this experiment was that thrombus was found in the pump. There was no frictional debris found around the LOA. The linear LVAS did not exhibit electrical or mechanical problems during the first animal experiment.

  13. Increasing LH pulsatility in women with hypothalamic amenorrhoea using intravenous infusion of Kisspeptin-54.

    Science.gov (United States)

    Jayasena, Channa N; Abbara, Ali; Veldhuis, Johannes D; Comninos, Alexander N; Ratnasabapathy, Risheka; De Silva, Akila; Nijher, Gurjinder M K; Ganiyu-Dada, Zainab; Mehta, Amrish; Todd, Catriona; Ghatei, Mohammad A; Bloom, Stephen R; Dhillo, Waljit S

    2014-06-01

    Hypothalamic amenorrhea (HA) is the one of the most common causes of period loss in women of reproductive age and is associated with deficient LH pulsatility. High-dose kisspeptin-54 acutely stimulates LH secretion in women with HA, but chronic administration causes desensitization. GnRH has paradoxical effects on reproductive activity; we therefore hypothesized that a dose-dependent therapeutic window exists within which kisspeptin treatment restores the GnRH/LH pulsatility in women with HA. The aim of the study was to determine whether constant iv infusion of kisspeptin-54 temporarily increases pulsatile LH secretion in women with HA. Five patients with HA each underwent six assessments of LH pulsatility. Single-blinded continuous iv infusion of vehicle or kisspeptin-54 (0.01, 0.03, 0.10, 0.30, or 1.00 nmol/kg/h) was administered. The LH pulses were detected using blinded deconvolution. Kisspeptin increased LH pulsatility in all patients with HA, with peak responses observed at different doses in each patient. The mean peak number of pulses during infusion of kisspeptin-54 was 3-fold higher when compared with vehicle (number of LH pulses per 8 h: 1.6 ± 0.4, vehicle; 5.0 ± 0.5, kisspeptin-54, P < .01 vs vehicle). The mean peak LH pulse secretory mass during kisspeptin-54 was 6-fold higher when compared with vehicle (LH pulse secretory mass in international units per liter: 3.92 ± 2.31, vehicle; 23.44 ± 12.59, kisspeptin-54; P < .05 vs vehicle). Kisspeptin-54 infusion temporarily increases LH pulsatility in women with HA. Furthermore, we have determined the dose range within which kisspeptin-54 treatment increases basal and pulsatile LH secretion in women with HA. This work provides a basis for studying the potential of kisspeptin-based therapies to treat women with HA.

  14. Concurrent use of continuous and pulsatile flow Ventricular Assist Device on a fontan patient: A simulation study.

    Science.gov (United States)

    Di Molfetta, Arianna; Ferrari, Gianfranco; Iacobelli, Roberta; Filippelli, Sergio; Amodeo, Antonio

    2017-01-01

    The aim of this work is to develop and test a lumped parameter model of the cardiovascular system to simulate the concurrent use of pulsatile (PVAD) and continuous flow (CVAD) ventricular assist device (VAD) on Fontan patients. Echocardiographic and hemodynamic data of five Fontan patients were retrospectively collected and used to simulate the patients' baseline hemodynamics. Then, for each patient, the following assistance modality was simulated for the cavopulmonary and the single ventricle (SV): (a) CVAD for cavopulmonary assistance (RCF) and PVAD assisting the SV (LCF) (RPF + LCF), (b) CVAD assisting SV and PVAD for cavopulmonary assistance (LPF + RCF). The numerical model can well reproduce patients' baseline. The cardiac output increases more importantly in the LCF + RPF configuration (35 vs. 8%). Ventricular volume decreases more evidently in the configuration LCF + RPF (28 vs. 6%), atrial pressure decreases in the LCF + RPF modality (10%), while it slightly increases in the RCF + LPF modality. The pulmonary arterial pressure slightly decreases (increases) in the configuration RCF + LPF (LCF + RPF). Ventricular external work increases in both configurations because of the total increment of the cardiac output. However, artero-ventricular coupling improves in both configurations: RCF + LPF-14%, LCF + RPF-41%. The pulsatility index decreases (increases) by 8% (13.8%) in the configuration LCF + RPF (RCF + LPF). A model could permit us to simulate extreme physiological conditions of the implantation of both CF and PF VAD on the Fontan patient and could permit to choose the proper VAD on the base of patients' condition. The configuration LCF + RPF seems to maximize the hemodynamic benefits. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Uric acid association with pulsatile and steady components of central and peripheral blood pressures.

    Science.gov (United States)

    Lepeytre, Fanny; Lavoie, Pierre-Luc; Troyanov, Stéphan; Madore, François; Agharazii, Mohsen; Goupil, Rémi

    2018-03-01

    Whether the cardiovascular risk attributed to elevated uric acid levels may be explained by changes in central and peripheral pulsatile and/or steady blood pressure (BP) components remains controversial. In a cross-sectional analysis of normotensive and untreated hypertensive participants of the CARTaGENE populational cohort, we examined the relationship between uric acid, and both pulsatile and steady components of peripheral and central BP, using sex-stratified linear regressions. Of the 20 004 participants, 10 161 individuals without antihypertensive or uric acid-lowering drugs had valid pulse wave analysis and serum uric acid levels. In multivariate analysis, pulsatile components of BP were not associated with uric acid levels, whereas steady components [mean BP (MBP), peripheral and central DBP] were all associated with higher levels of uric acid levels in women and men (all P uric acid levels but not for MBP-adjusted cSBP. Peripheral and cSBP, which are aggregate measures of pulsatile and steady BP, were also associated with uric acid levels in women (β = 0.063 and 0.072, respectively, both P uric acid levels. Serum uric acid levels appear to be associated with both central and peripheral steady but not pulsatile BP, regardless of sex.

  16. Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device.

    Science.gov (United States)

    Date, Kazuma; Nishimura, Takashi; Arakawa, Mamoru; Takewa, Yoshiaki; Kishimoto, Satoru; Umeki, Akihide; Ando, Masahiko; Mizuno, Toshihide; Tsukiya, Tomonori; Ono, Minoru; Tatsumi, Eisuke

    2017-03-01

    Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART ® ; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to ventricular pacing. We shifted the timing of increasing RS from -60 to +60 ms in the systolic phase. We found significant increases in all the following parameters when assessments of delayed timing (+60 ms) were compared with assessments of advanced timing (-60 ms): pulse pressure, mean dP/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.

  17. Static and Functional Hemodynamic Profiles of Women with Abnormal Uterine Artery Doppler at 22-24 Weeks of Gestation.

    Science.gov (United States)

    Vårtun, Åse; Flo, Kari; Widnes, Christian; Acharya, Ganesh

    2016-01-01

    To compare cardiac function, systemic hemodynamics and preload reserve of women with increased (cases) and normal (controls) uterine artery (UtA) pulsatility index (PI) at 22-24 weeks of gestation. A prospective cross-sectional study of 620 pregnant women. UtA blood flow velocities were measured using Doppler ultrasonography, and PI was calculated. Mean UtA PI ≥ 1.16 (90th percentile) was considered abnormal. Maternal hemodynamics was investigated at baseline and during passive leg raising (PLR) using impedance cardiography (ICG). Preload reserve was defined as percent increase in stroke volume (SV) 90 seconds after passive leg raising compared to baseline. Mean UtA PI was 1.49 among cases (n = 63) and 0.76 among controls (n = 557) (p UtA PI had higher blood pressure and systemic vascular resistance, but similar functional hemodynamic profile at 22-24 weeks compared to controls. Further studies are needed to clarify whether functional hemodynamic assessment using ICG can be useful in predicting pregnancy complications.

  18. Orexin-A suppresses the pulsatile secretion of luteinizing hormone via beta-endorphin.

    Science.gov (United States)

    Irahara, M; Tamura, T; Matuzaki, T; Saito, S; Yasui, T; Yamano, S; Kamada, M; Aono, T

    2001-02-16

    Orexins, the novel hypothalamic neuropeptides that stimulate feeding behavior, have been shown to suppress the pulsatile secretion of LH in ovariectomized rats. However, the mechanism of this action is still not clear. We examined the effect of naloxone, a specific opioid antagonist, on the suppression of the pulsatile secretion of LH by orexins to determine whether beta-endorphin is involved in this suppressive effect. We administered orexins intracerebroventricularly and injected naloxone intravenously in ovariectomized rats, and we measured the serum LH concentration to analyze the pulsatile secretion. Administration of orexin-A significantly reduced the mean LH concentration and the pulse frequency, but coadministration of naloxone significantly restored the mean LH concentration and the pulse frequency. Administration of orexin-B also significantly reduced the mean LH concentration and the pulse frequency, and coadministration of naloxone did not restore them. These results indicate that orexin-A, but not orexin-B, suppresses GnRH secretion via beta-endorphin.

  19. Superior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications

    Directory of Open Access Journals (Sweden)

    Neema Praveen

    2009-01-01

    Full Text Available Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.

  20. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Geir Ringstad

    Full Text Available Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43. Pulse pressure gradients were also similar in patients and healthy controls (P = .26, and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97. Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate

  1. Obstructive Hydrocephalus Secondary to Enlarged Virchow-Robin Spaces: A Rare Cause of Pulsatile Tinnitus.

    Science.gov (United States)

    Donaldson, Christopher; Chatha, Gurkirat; Chandra, Ronil V; Goldschlager, Tony

    2017-05-01

    Obstructive hydrocephalus secondary to enlarged Virchow-Robin Spaces (VRS) is a rare entity, with only a few cases reported in the literature. Presenting symptoms vary widely from headaches to dizziness. We report a case of a 31-year-old man who presented with pulsatile tinnitus and magnetic resonance imaging showing obstructive hydrocephalus secondary to tumefactive VRS. After a cerebrospinal fluid diversion procedure in the form of an endoscopic third ventriculostomy, he had almost complete resolution of his symptoms. This is the first case of obstructive hydrocephalus secondary to enlarged VRS, presenting with pulsatile tinnitus. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Effects of pulsatile L-DOPA treatment in the double lesion rat model of striatonigral degeneration (multiple system atrophy).

    Science.gov (United States)

    Stefanova, N; Lundblad, M; Tison, F; Poewe, W; Cenci, M A; Wenning, G K

    2004-04-01

    We examined the role of a striatal lesion in the development of L-DOPA-induced abnormal involuntary movements (AIMs) using the double lesion rat model of striatonigral degeneration (SND), the underlying neuropathological substrate of parkinsonism associated with multiple system atrophy (MSA-P), in comparison to a Parkinson's disease (PD) rat model. L-DOPA administration reliably induced AIMs in SND and PD rats in a dose-dependent fashion. AIMs occurred significantly earlier in SND compared to PD rats. There was a mild, but significant, transient increase of orolingual AIMs during the first week of low-dose L-DOPA treatment in SND. Whereas L-DOPA significantly improved contralateral forelimb akinesia in PD rats, there was no beneficial effect in SND rats. Striatal FosB/Delta FosB up-regulation in SND and PD rats correlated with the severity of L-DOPA-induced dyskinesias. Pulsatile L-DOPA administration in the double lesion SND rat model replicates salient features of the human disease MSA-P, including loss of the anti-akinetic L-DOPA response and induction of dyskinesias with transient orolingual predominance.

  3. Tooth - abnormal colors

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003065.htm Tooth - abnormal colors To use the sharing features on this page, please enable JavaScript. Abnormal tooth color is any color other than white to yellowish- ...

  4. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  5. Abnormal uterine bleeding

    Science.gov (United States)

    Anovulatory bleeding; Abnormal uterine bleeding - hormonal; Polymenorrhea - dysfunctional uterine bleeding ... ACOG committee opinion no. 557: Management of acute abnormal uterine bleeding in nonpregnant reproductive-aged women. Reaffirmed 2015. ACOG. ...

  6. Pulsatile protein release from monodisperse liquid-core microcapsules of controllable shell thickness

    Science.gov (United States)

    Xia, Yujie; Pack, Daniel W.

    2014-01-01

    Purpose Pulsatile delivery of proteins, in which release occurs over a short time after a period of little or no release, is desirable for many applications. This paper investigates the effect of biodegradable polymer shell thickness on pulsatile protein release from biodegradable polymer microcapsules. Methods Using precision particle fabrication (PPF) technology, monodisperse microcapsules were fabricated encapsulating bovine serum albumin (BSA) in a liquid core surrounded by a drug-free poly(lactide-co-glycolide) (PLG) shell of uniform, controlled thickness from 14 to 19 μm. Results When using high molecular weight PLG (Mw 88 kDa), microparticles exhibited the desired core-shell structure with high BSA loading and encapsulation efficiency (55-65%). These particles exhibited very slow release of BSA for several weeks followed by rapid release of 80-90% of the encapsulated BSA within seven days. Importantly, with increasing shell thickness the starting time of the pulsatile release could be controlled from 25 to 35 days. Conclusions Biodegradable polymer microcapsules with precisely controlled shell thickness provide pulsatile release with enhanced control of release profiles. PMID:24831313

  7. Partial thickness autologus calvarial bone orbitocranioplasty for a sphenorbital encephalocele presenting as pulsatile exophthalmos

    OpenAIRE

    Trivedi, Adarsh; Garg, Amrish Kumar; Hiran, Subodh

    2015-01-01

    Basal encephalocele accounts only 1.5% of all encephaloceles. But Sphenorbital encephalocele is the rarest cause of herniation of brain into orbit leading to pulsatile exphothalmos. Authors presenting a case of sphenorbital encephalocele in a 16 yrs old girl successsfully managed by orbitcranioplasty by partilal thickness autologus calvarial bone graft.

  8. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  9. Pulsatile hyperglucagonemia fails to increase hepatic glucose production in normal man

    International Nuclear Information System (INIS)

    Paolisso, G.; Scheen, A.J.; Luyckx, A.S.; Lefebvre, P.J.

    1987-01-01

    To study the metabolic effects of pulsatile glucagon administration, six male volunteers were submitted to a 260-min glucose-controlled glucose intravenous infusion using the Biostator. The endogenous secretion of the pancreatic hormones was inhibited by somatostatin, basal insulin secretion was replaced by a continuous insulin infusion, and glucagon was infused intravenously in two conditions at random: either continuously or intermittently. Blood glucose levels and glucose infusion rate were monitored continuously by the Biostator, and classical methodology using a D-[3- 3 H]glucose infusion allowed the authors to study glucose turnover. While basal plasma glucagon levels were similar in both conditions, they plateaued at 189 +/- 38 pg ml -1 during continuous infusion and varied between 95 and 501 pg x ml -1 during pulsatile infusion. When compared with continuous administration, pulsatile glucagon infusion 1) initially induced a similar increase in endogenous (hepatic) glucose production and blood glucose, 2) did not prevent the so-called evanescent effect of glucagon on blood glucose, and 3) after 3 h tended to reduce rather than increase hepatic glucose production. In conclusion, in vivo pulsatile hyperglucanemia in normal man fails to increase hepatic glucose production

  10. An in vitro experimental study of flow past aortic valve under varied pulsatile conditions

    Science.gov (United States)

    Zhang, Ruihang; Zhang, Yan

    2017-11-01

    Flow past aortic valve represents a complex fluid-structure interaction phenomenon that involves pulsatile, vortical, and turbulent conditions. The flow characteristics immediately downstream of the valve, such as the variation of pulsatile flow velocity, formation of vortices, distribution of shear stresses, are of particular interest to further elucidate the role of hemodynamics in various aortic diseases. However, the fluid dynamics of a realistic aortic valve is not fully understood. Particularly, it is unclear how the flow fields downstream of the aortic valve would change under varied pulsatile inlet boundary conditions. In this study, an in vitro experiment has been conducted to investigate the flow fields downstream of a silicone aortic valve model within a cardiovascular flow simulator. Phased-locked Particle Image Velocimetry measurements were performed to map the velocity fields and Reynolds normal and shear stresses at different phases in a cardiac cycle. Temporal variations of pressure across the valve model were measured using high frequency transducers. Results have been compared for different pulsatile inlet conditions, including varied frequencies (heart rates), magnitudes (stroke volumes), and cardiac contractile functions (shapes of waveforms).

  11. Pulsatile secretion of thyrotropin during fasting: a decrease of thyrotropin pulse amplitude

    NARCIS (Netherlands)

    Romijn, J. A.; Adriaanse, R.; Brabant, G.; Prank, K.; Endert, E.; Wiersinga, W. M.

    1990-01-01

    The effect of fasting on circadian and pulsatile TSH secretion was investigated in eight healthy subjects (four men and four women in the follicular phase). Each subject was studied twice, once during 24 h with normal food intake and once during the last 24 h of a 60-h fast. Blood was sampled every

  12. Time and pH dependent colon specific, pulsatile delivery of theophylline for nocturnal asthma.

    Science.gov (United States)

    Mastiholimath, V S; Dandagi, P M; Jain, S Samata; Gadad, A P; Kulkarni, A R

    2007-01-02

    In this study, investigation of an oral colon specific, pulsatile device to achieve time and/or site specific release of theophylline, based on chronopharmaceutical consideration. The basic design consists of an insoluble hard gelatin capsule body, filled with eudragit microcapsules of theophylline and sealed with a hydrogel plug. The entire device was enteric coated, so that the variability in gastric emptying time can be overcome and a colon-specific release can be achieved. The theophylline microcapsules were prepared in four batches, with Eudragit L-100 and S-100 (1:2) by varying drug to polymer ratio and evaluated for the particle size, drug content and in vitro release profile and from the obtained results; one better formulation was selected for further fabrication of pulsatile capsule. Different hydrogel polymers were used as plugs, to maintain a suitable lag period and it was found that the drug release was controlled by the proportion of polymers used. In vitro release studies of pulsatile device revealed that, increasing the hydrophilic polymer content resulted in delayed release of theophylline from microcapsules. The gamma scintigraphic study pointed out the capability of the system to release drug in lower parts of GIT after a programmed lag time for nocturnal asthma. Programmable pulsatile, colon-specific release has been achieved from a capsule device over a 2-24h period, consistent with the demands of chronotherapeutic drug delivery.

  13. Effects of Thoratec pulsatile ventricular assist device timing on the abdominal aortic wave intensity pattern.

    Science.gov (United States)

    Jahren, Silje Ekroll; Amacher, Raffael; Weber, Alberto; Most, Henriette; Flammer, Shannon Axiak; Traupe, Tobias; Stoller, Michael; de Marchi, Stefano; Vandenberghe, Stijn

    2014-10-15

    Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging, and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculoaortic cannulation. The start of PVAD ejection was synchronized to the native R wave and delayed between 0 and 90% of the cardiac cycle in 10% steps or phase shifts (PS). Pressure and velocity signals were registered, with the use of a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe that noninvasive WIA could potentially be used clinically to assess the mechanical load of the LV and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding. Copyright © 2014 the American Physiological Society.

  14. Pulsatile Lavage of Musculoskeletal Wounds Causes Muscle Necrosis and Dystrophic Calcification in a Rat Model.

    Science.gov (United States)

    Chiaramonti, Alexander M; Robertson, Astor D; Nguyen, Thao P; Jaffe, David E; Hanna, E Lex; Holmes, Robert; Barfield, William R; Fourney, William L; Stains, Joseph P; Pellegrini, Vincent D

    2017-11-01

    Adequate irrigation of open musculoskeletal injuries is considered the standard of care to decrease bacterial load and other contaminants. While the benefit of debris removal compared with the risk of further seeding by high-pressure lavage has been studied, the effects of irrigation on muscle have been infrequently reported. Our aim in the present study was to assess relative damage to muscle by pulsatile lavage compared with bulb-syringe irrigation. In an animal model of heterotopic ossification, 24 Sprague-Dawley rats underwent hindlimb blast amputation via detonation of a submerged explosive, with subsequent through-the-knee surgical amputation proximal to the zone of injury. All wounds were irrigated and underwent primary closure. In 12 of the animals, pulsatile lavage (20 psi [138 kPa]) was used as the irrigation method, and in the other 12 animals, bulb-syringe irrigation was performed. A third group of 6 rats did not undergo the blast procedure but instead underwent surgical incision into the left thigh muscle followed by pulsatile lavage. Serial radiographs of the animals were made to monitor the formation of soft-tissue radiopaque lesions until euthanasia at 6 months. Image-guided muscle biopsies were performed at 8 weeks and 6 months (at euthanasia) on representative animals from each group. Histological analysis was performed with hematoxylin and eosin, alizarin red, and von Kossa staining on interval biopsy and postmortem specimens. All animals managed with pulsatile lavage, with or without blast injury, developed soft-tissue radiopaque lesions, whereas no animal that had bulb-syringe irrigation developed these lesions (p = 0.001). Five of the 12 animals that underwent blast amputation with pulsatile lavage experienced wound complications, whereas no animal in the other 2 groups experienced wound complications (p = 0.014). Radiopaque lesions appeared approximately 10 days postoperatively, increased in density until approximately 16 weeks, then

  15. Static and Functional Hemodynamic Profiles of Women with Abnormal Uterine Artery Doppler at 22-24 Weeks of Gestation.

    Directory of Open Access Journals (Sweden)

    Åse Vårtun

    Full Text Available To compare cardiac function, systemic hemodynamics and preload reserve of women with increased (cases and normal (controls uterine artery (UtA pulsatility index (PI at 22-24 weeks of gestation.A prospective cross-sectional study of 620 pregnant women. UtA blood flow velocities were measured using Doppler ultrasonography, and PI was calculated. Mean UtA PI ≥ 1.16 (90th percentile was considered abnormal. Maternal hemodynamics was investigated at baseline and during passive leg raising (PLR using impedance cardiography (ICG. Preload reserve was defined as percent increase in stroke volume (SV 90 seconds after passive leg raising compared to baseline.Mean UtA PI was 1.49 among cases (n = 63 and 0.76 among controls (n = 557 (p < 0.0001. Eighteen (28.6% cases and 53 (9.5% controls developed pregnancy complications (p <0.0001. The mean arterial pressure and systemic vascular resistance were 83 mmHg and 1098.89±293.87 dyne s/cm5 among cases and 79 mmHg and 1023.95±213.83 dyne s/cm5 among controls (p = 0.007 and p = 0.012, respectively. Heart rate, SV and cardiac output were not different between the groups. Both cases and controls responded with a small (4-5% increase in SV in response to PLR, but the cardiac output remained unchanged. The preload reserve was not significantly different between two groups.Pregnant women with abnormal UtA PI had higher blood pressure and systemic vascular resistance, but similar functional hemodynamic profile at 22-24 weeks compared to controls. Further studies are needed to clarify whether functional hemodynamic assessment using ICG can be useful in predicting pregnancy complications.

  16. Increasing awareness with recognition of pulsatile tinnitus for nurse practitioners in the primary care setting: A case study.

    Science.gov (United States)

    Vecchiarelli, Kelly; Amar, Arun Paul; Emanuele, Donna

    2017-09-01

    Pulsatile tinnitus is a whooshing sound heard synchronous with the heartbeat. It is an uncommon symptom affecting fewer than 10% of patients with tinnitus. It often goes unrecognized in the primary care setting. Failure to recognize this symptom can result in a missed or delayed diagnosis of a potentially life-threatening condition known as a dural arteriovenous fistula. The purpose of this case study is to provide a structured approach to the identification of pulsatile tinnitus and provide management recommendations. A case study and review of pertinent literature. Pulsatile tinnitus usually has a vascular treatable cause. A comprehensive history and physical examination will alert the nurse practitioner (NP) when pulsatile tinnitus is present. Auscultation in specific areas of the head can detect audible or objective pulsatile tinnitus. Pulsatile tinnitus that is audible to the examiner is an urgent medical condition requiring immediate consultation and referral. Knowledge of pulsatile tinnitus and awareness of this often treatable condition directs the NP to perform a detailed assessment when patients present with tinnitus, directs appropriate referral for care and treatment, and can reduce the risk of delayed or missed diagnosis. ©2017 American Association of Nurse Practitioners.

  17. Clinical effectiveness of centrifugal pump to produce pulsatile flow during cardiopulmonary bypass in patients undergoing cardiac surgery.

    Science.gov (United States)

    Gu, Y John; van Oeveren, Willem; Mungroop, Hubert E; Epema, Anne H; den Hamer, Inez J; Keizer, Jorrit J; Leuvenink, Ron P; Mariani, Massimo A; Rakhorst, Gerhard

    2011-02-01

    Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate whether the Rotaflow centrifugal pump produces effective pulsatile flow during CPB and whether the pulsatile flow in this setting is clinically effective in adult patients undergoing cardiac surgery. Thirty-two patients undergoing CPB for elective coronary artery bypass grafting were randomly allocated to a pulsatile perfusion group (n = 16) or a nonpulsatile perfusion group (n = 16). All patients were perfused with the Rotaflow centrifugal pump. In the pulsatile group, the centrifugal pump was adjusted to the pulsatile mode (60 cycles/min) during aortic cross-clamping, whereas in the nonpulsatile group, the pump was kept in its nonpulsatile mode during the same period of time. Compared with the nonpulsatile group, the pulsatile group had a higher pulse pressure (P centrifugal pump is associated with a small gain of EEP and SHE, which does not seem to be clinically effective in adult cardiac surgical patients. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Is the use of low-pressure pulsatile lavage for pressure ulcer management associated with environmental contamination with Acinetobacter baumannii?

    Science.gov (United States)

    Ho, Chester H; Johnson, Tova; Miklacic, Joan; Donskey, Curtis J

    2009-10-01

    Ho CH, Johnson T, Miklacic J, Donskey CJ. Is the use of low-pressure pulsatile lavage for pressure ulcer management associated with environmental contamination with Acinetobacter baumannii? To determine the extent of environmental contamination associated with low-pressure pulsatile lavage of stage III or IV pressure ulcers in patients with spinal cord injury (SCI) when routine infection control precautions are used for wounds colonized or infected with Acinetobacter baumannii. Prospective investigation in which pressure ulcer cultures and environmental cultures were obtained before and after low-pressure pulsatile lavage treatment, and before and after regular dressing changes. Environmental cultures included the patient's bedrail and settle plates placed 0.6, 1.5, and 2.4m from the wound to assess airborne spread of A. baumannii. SCI inpatient unit in a Department of Veterans Affairs Medical Center. Inpatients (N=15) with SCI receiving daily low-pressure pulsatile lavage treatment for stage III or IV pressure ulcers with standard dressing change, as well as regular dressing changes without low-pressure pulsatile lavage at other times of the day. Standard, regular dressing changes and dressing changes with low-pressure pulsatile lavage. Comparison of frequency of environmental contamination with A. baumannii associated with low-pressure pulsatile lavage versus regular dressing changes. Of the 15 SCI inpatients meeting inclusion criteria, 9 (60%) grew A. baumannii from their wounds. Of the 9 patients with wound cultures positive for A. baumannii, only 1 (11%) had environmental contamination with this organism after performance of low-pressure pulsatile lavage, and the same patient had environmental contamination after a standard dressing change. The antibiotic susceptibility patterns of the wound and environmental A. baumannii isolates were identical. Low-pressure pulsatile lavage using the infection control methods described is not associated with an increased

  19. The association between the pulse pressure gradient at the cranio-cervical junction derived from phase-contrast magnetic resonance imaging and invasively measured pulsatile intracranial pressure in symptomatic patients with Chiari malformation type 1.

    Science.gov (United States)

    Frič, Radek; Lindstrøm, Erika Kristina; Ringstad, Geir Andre; Mardal, Kent-André; Eide, Per Kristian

    2016-12-01

    In symptomatic Chiari malformation type 1 (CMI), impaired intracranial compliance (ICC) is associated with an increased cranio-spinal pulsatile pressure gradient. Phase-contrast magnetic resonance imaging (MRI) represents a non-invasive modality for the assessment of the pulse pressure gradient at the cranio-cervical junction (CCJ). We wished to explore how the MRI-derived pulse pressure gradient (MRI-dP) compares with invasively measured pulsatile intracranial pressure (ICP) in CMI, and with healthy controls. From phase-contrast MRI of CMI patients and healthy controls, we computed cerebrospinal fluid (CSF) flow velocities and MRI-dP at the CCJ. We assessed bidirectional flow and compared the flow between the anterior and the posterior subarachnoid space at the CCJ. We computed total intracranial volume (ICV), ventricular CSF volume (VV), and posterior cranial fossa volume (PCFV). We analyzed the static and pulsatile ICP scores from overnight monitoring in CMI patients. Five CMI patients and four healthy subjects were included. The CMI group had a significantly larger extent of tonsillar ectopia, smaller PCFV, and a smaller area of CSF in the FM. The pulsatile ICP (mean ICP wave amplitude, MWA) was abnormally increased in 4/5 CMI patients and correlated positively with MRI-dP. However, the MRI-dP as well as the CSF flow velocities did not differ significantly between CMI and healthy subjects. Moreover, bidirectional flow was observed in both CMI as well as healthy subjects, with no significant difference. In symptomatic CMI patients, we found a significant association between the pulse pressure gradient at the CCJ derived from phase-contrast MRI and the pulsatile ICP (MWA) measured invasively. However, the MRI-dP was close to identical in CMI patients and healthy subjects. Moreover, the CSF flow velocities at the CCJ and the occurrence of bidirectional flow were not different in CMI patients and healthy individuals. Further studies are required to determine the

  20. PULSATILE ARTERIAL PRESSURE (PAP AND VASCULAR REMODELLING INDICES: SEARCH OF EARLY SYMPTOMS OF CARDIOVASCULAR PATHOLOGY IN CHILDREN

    Directory of Open Access Journals (Sweden)

    O. V. Kozhevnikova

    2015-01-01

    Full Text Available Objective: To determine the standards of pulsatile arterial pressure (PAP in healthy children and the possibility to use PAP as an indicator of the condition of vessels in children with increased body mass index (BMI. Methods: The results of non-invasive arteriography in children aged 3–17 years with normal (apparently healthy children, n =291 and increased BMI (n =211 are presented. A group of children with normal BMI was formed by dispensary examinations in schools and kindergartens. Children with increased BMI (secondary nature of overweight and obesity are excluded were observed as outpatients. The PAP analysis was carried out in regard to age, sex, height, and BMI. The interaction of PAP with other hemodynamics and vascular remodelling indices was investigated. Results: PAP percentile tables in healthy children by age and growth groups are obtained. PAP above the 90th percentile is diagnosed in 7.2% of apparently healthy children, in 7.7% of overweight and in 22.4% of obese children. The dependence of the PAP rate on age, height and BMI is shown. The connection of high PAP in overweight children with signs of the vascular wall remodelling is established. Conclusion: The presented percentile tables of PAP rates in healthy children with normal BMI can be used to detect increased PAP in children at risk of cardiovascular disease developing.

  1. Precise position control of a helical magnetic robot in pulsatile flow using the rotating frequency of the external magnetic field

    Directory of Open Access Journals (Sweden)

    Jongyul Kim

    2017-05-01

    Full Text Available We propose a position control method for a helical magnetic robot (HMR that uses the rotating frequency of the external rotating magnetic field (ERMF to minimize the position fluctuation of the HMR caused by pulsatile flow in human blood vessels. We prototyped the HMR and conducted several experiments in pseudo blood vessel environments with a peristaltic pump. We experimentally obtained the relation between the flow rate and the rotating frequency of the ERMF required to make the HMR stationary in a given pulsatile flow. Then we approximated the pulsatile flow by Fourier series and applied the required ERMF rotating frequency to the HMR in real time. Our proposed position control method drastically reduced the position fluctuation of the HMR under pulsatile flow.

  2. Defining Abnormally Low Tenders

    DEFF Research Database (Denmark)

    Ølykke, Grith Skovgaard; Nyström, Johan

    2017-01-01

    The concept of an abnormally low tender is not defined in EU public procurement law. This article takes an interdisciplinary law and economics approach to examine a dataset consisting of Swedish and Danish judgments and verdicts concerning the concept of an abnormally low tender. The purpose...

  3. Surgical management of pulsatile tinnitus secondary to jugular bulb or sigmoid sinus diverticulum with review of literature.

    Science.gov (United States)

    Yeo, W X; Xu, S H; Tan, T Y; Low, Y M; Yuen, H W

    Jugular bulb and sigmoid sinus anomalies are well-known causes of vascular pulsatile tinnitus. Common anomalies reported in the literature include high-riding and/or dehiscent jugular bulb, and sigmoid sinus dehiscence. However, cases of pulsatile tinnitus due to diverticulosis of the jugular bulb or sigmoid sinus are less commonly encountered, with the best management option yet to be established. In particular, reports on surgical management of pulsatile tinnitus caused by jugular bulb diverticulum have been lacking in the literature. To report two cases of pulsatile tinnitus with jugular bulb and/or sigmoid sinus diverticulum, and their management strategies and outcomes. In this series, we describe the first reported successful case of pulsatile tinnitus due to jugular bulb diverticulum that was surgically-treated. Two patients diagnosed with either jugular bulb and/or sigmoid sinus diverticulum, who had presented to the Otolaryngology clinic with pulsatile tinnitus between 2016 and 2017, were studied. Demographic and clinical data were obtained, including their management details and clinical outcomes. Two cases (one with jugular bulb diverticulum and one with both sigmoid sinus and jugular bulb diverticula) underwent surgical intervention, and both had immediate resolution of pulsatile tinnitus post-operatively. This was sustained at subsequent follow-up visits at the outpatient clinic, and there were no major complications encountered for both cases intra- and post-operatively. Transmastoid reconstruction/resurfacing of jugular bulb and sigmoid sinus diverticulum with/without obliteration of the diverticulum is a safe and effective approach in the management of bothersome pulsatile tinnitus arising from these causes. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Nanoscaffold matrices for size-controlled, pulsatile transdermal testosterone delivery: nanosize effects on the time dimension

    Science.gov (United States)

    Malik, Ritu; Tondwal, Shailesh; Venkatesh, K. S.; Misra, Amit

    2008-10-01

    Pulsatile transdermal testosterone (T) has applications in hormone supplementation and male contraception. Pulsatile T delivery was achieved by assembling crystalline and nanoparticulate T in nucleation-inhibiting polymer matrices of controlled porosity. Different interference patterns observed from various polymeric films containing T were due to the various particle sizes of T present in the polymer matrices. Scanning electron microscopy was used to determine the size and shape of T crystals. Skin-adherent films containing T nanoparticles of any size between 10-500 nm could be prepared using pharmaceutically acceptable vinylic polymers. Drug release and skin permeation profiles were studied. The dissolution-diffusion behavior of nanoparticles differed from crystalline and molecular states. Nanosize may thus be used to engineer chronopharmacologically relevant drug delivery.

  5. Pulsatile turbulent flow through pipe bends at high Dean and Womersley numbers

    International Nuclear Information System (INIS)

    Kalpakli, Athanasia; Örlü, Ramis; Tillmark, Nils; Alfredsson, P Henrik

    2011-01-01

    Turbulent pulsatile flows through pipe bends are prevalent in internal combustion engine components which consist of bent pipe sections and branching conduits. Nonetheless, most of the studies related to pulsatile flows in pipe bends focus on incompressible, low Womersley and low Dean number flows, primarily because they aim in modeling blood flow, while internal combustion engine related flows have mainly been addressed in terms of integral quantities and consist of single point measurements. The present study aims at bridging the gap between these two fields by means of time-resolved stereoscopic particle image velocimetry measurements in a pipe bend with conditions that are close to those encountered in exhaust manifolds. The time/phase-resolved three-dimensional cross-sectional flow-field 3 pipe diameters downstream the pipe bend is captured and the interplay between different secondary motions throughout a pulse cycle is discussed.

  6. Estimation of Several Turbulent Fluctuation Quantities Using an Approximate Pulsatile Flow Model

    Energy Technology Data Exchange (ETDEWEB)

    Dechant, Lawrence J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    Turbulent fluctuation behavior is approximately modeled using a pulsatile flow model analogy.. This model follows as an extension to the turbulent laminar sublayer model developed by Sternberg (1962) to be valid for a fully turbulent flow domain. Here unsteady turbulent behavior is modeled via a sinusoidal pulsatile approach. While the individual modes of the turbulent flow fluctuation behavior are rather crudely modeled, approximate temporal integration yields plausible estimates for Root Mean Square (RMS) velocity fluctuations. RMS pressure fluctuations and spectra are of particular interest and are estimated via the pressure Poisson expression. Both RMS and Power Spectral Density (PSD), i.e. spectra are developed. Comparison with available measurements suggests reasonable agreement. An additional fluctuating quantity, i.e. RMS wall shear fluctuation is also estimated, yielding reasonable agreement with measurement.

  7. Pulsatile flow-induced angiogenesis: role of G(i) subunits.

    Science.gov (United States)

    Cullen, John P; Sayeed, Shariq; Sawai, Rebecca S; Theodorakis, Nicholas G; Cahill, Paul A; Sitzmann, James V; Redmond, Eileen M

    2002-10-01

    Angiogenesis plays a key role in the growth and function of normal and pathological tissues. We investigated the effect of pulsatile flow on endothelial cell (EC) in vitro angiogenic activity. Bovine aortic ECs were exposed to "static" or "flow" (1.2 to 67.0 mL/min, shear stress 1.4 to 19.2 dyne/cm2) conditions for 2 to 24 hours. After exposure, angiogenesis was measured as tubule formation on Matrigel, and EC migration was assessed by filter migration assay. Pulsatile flow increased angiogenesis and EC migration in a temporal and force-dependent manner, with a maximal effect at 16 hours (13.2 dyne/cm2). Pertussis toxin completely inhibited the effect of pulsatile flow on angiogenesis and migration. Transfection of ECs with inhibitory mutants of the alpha subunit of G(i)1 or G(i)3, but not G(i)2, inhibited the flow-induced angiogenic response by 61+/-2% and 32+/-6%, respectively, whereas transfection with constitutively activated mutants of the alpha subunit of G(i)1 or G(i)3, but not G(i)2, increased the flow-induced response by 202+/-23% and 70+/-4%, respectively. In contrast, inhibition of Gbetagamma by the carboxy terminal fragment of beta-adrenergic receptor kinase overexpression increased the flow-induced response by 82+/-8%. These results suggest that pulsatile flow stimulates angiogenesis and that this effect is mediated by activation of G(ialpha)1 or G(ialpha)3, but not Gbetagamma, subunits.

  8. Lateralization effects on functional connectivity of the auditory network in patients with unilateral pulsatile tinnitus as detected by functional MRI.

    Science.gov (United States)

    Lv, Han; Zhao, Pengfei; Liu, Zhaohui; Liu, Xuehuan; Ding, Heyu; Liu, Liheng; Wang, Guopeng; Xie, Jing; Zeng, Rong; Chen, Yuchen; Yang, Zhenghan; Gong, Shusheng; Wang, Zhenchang

    2018-02-02

    Unilateral pulsatile tinnitus (PT) was proved to be a kind of disease with brain functional abnormalities within and beyond the auditory network (AN). However, changes in patterns of the lateralization effects of PT are yet to be established. Relationship between the AN and other brain networks in PT patients is also a scientific question need to be answered. In this study, we recruited 23 left-sided, 23 right-sided PT (LSPT, RSPT) patients and 23 normal controls (NC). We combined applied independent component analysis and seed-based functional connectivity (FC) analysis to investigate alteration feature of the FC of the AN by using resting-state functional magnetic resonance imaging (rs-fMRI). Compared with NC, LSPT patients demonstrated disconnected FC within the AN on both sides. Disrupted network integrity between AN and several brain functional networks, including executive control network, self-perceptual network and the limbic network, was also demonstrated in LSPT patient group bilaterally. In contrast, compared with NC, RSPT demonstrated decreased FC within the AN on the left side, but significant increased FC within the AN on the right side (symptomatic side). Enhanced FC between AN and executive control network, self-perceptual network and limbic network was also found mainly on the right side in patients with RSPT. Positive FC between the auditory network and the limbic network may be a reason to explain why RSPT patients are willing to be in the clinic. Briefly, LSPT exhibit disrupted network integrity in brain functional networks. But RSPT is featured by enhanced FC within AN and between networks, especially on the right (symptomatic) side. Corroboration of featured FC helps to reveal the pathophysiological changing process of the brain in patients with PT, providing imaging-based biomarker to distinguish PT from other kind of tinnitus. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Experimental study on quantitative evaluation of slow pulsatile flow of CSF with cine MRI

    International Nuclear Information System (INIS)

    Matsuda, Masao

    1991-01-01

    The present study was designed to evaluate the slow pulsatile flow of cerebrospinal fluid (CSF) quantitatively with cine MRI in phantom experiment for the clinical application. The flow phantom was constructed from a plastic tube with a narrow channel to represent the central aqueduct. The phantom was filled with water to represent the CSF. The second tube filled with stationary water was positioned beside the flow phantom and acted as a control for no-flow signal strength. The ratio of signal intensity in regions of interest for the flow phantom and the control was measured. Not only the actual velocity curve of the flowing water through the phantom but also the temporal profile of signal intensity showed two main peaks with other small peaks in one cycle. This suggested a close relationship between signal intensity of cine MRI and flow velocity. A significant correlation between the signal intensity ratio and the velocity was obtained on cine MRI pulse sequences. Cine MRI was thus found to have the ability to give quantitative information about slow pulsatile flow. The most suitable pulse sequence was fast imaging with steady state free precession pulse sequence at the flip angle between 50 and 90 degrees. This preliminary study suggests that the slow pulsatile flow of CSF passing along the aqueduct can be visualized and measured. Thus, the sequence proposed has a potential for the investigation of normal and disturbed CSF circulation and the mapping of the flow pattern in different pathological conditions. (N.K.)

  10. Vortex propagation around a wall-mounted obstacle in pulsatile flow

    Science.gov (United States)

    Carr, Ian A.; Plesniak, Michael W.

    2015-11-01

    Wall-mounted obstacles are prevalent in nature and engineering applications. Physiological flows observed in human vocal fold pathologies, such as polyps, can be modeled by flow over a wall-mounted protuberance. Despite their prevalence, studies of wall-mounted obstacles have been restricted to steady (constant velocity) freestream flow. In biological and geophysical applications, pulsatile flow is much more common, yet effects of pulsatility on the wake of a wall-mounted obstacle remain to be extensively studied. This study aims to characterize the complex physics produced in this unsteady, separated flow. Experiments were performed in a low-speed wind tunnel with a set of rotating vanes, which produce the pulsatile inflow waveform. Instantaneous and phase-averaged particle image velocimetry (PIV) results acquired around a hemispherical obstacle are presented and compared. A mechanism based on self-induced vortex propagation, analogous to that in vortex rings, is proposed to explain the observed dynamics of coherent structures. Predictions of the propagation velocity based on analytical expressions for vortex rings in a viscous fluid are compared to the experimentally measured propagation velocity. Effects of the unsteady boundary layer on the observed physics are explored. This material is based in part upon work supported by the National Science Foundation under Grant Number CBET-1236351, and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  11. Plant abnormality diagnosis device

    International Nuclear Information System (INIS)

    Saeki, Akira.

    1992-01-01

    The device of the present invention diagnose an abnormal event occurred in a large-scaled plant, such as a nuclear power plant. The device comprises the following four functions. (1) Abnormality candidates are estimated based on an intelligence base storing characteristics established between the characteristics/functions and physical amounts of the plant components, and detected abnormality and measured values. Among the candidates, one which coincidents with the measured value such as an actual process amount is judged as a first cause. (2) In addition, a real time plant behavior is estimated based on parameters determining a plant operation mode. The candidate for the abnormality cause is estimated by the comparison between the result of the estimation and the measured value such as a process amount. (3) Characteristics established between the characteristics/functions and the physical amount of the plant components are structured stepwise thereby identifying the first abnormality cause. (4) Inactuated or failed portions of the components for restoring the abnormality to normal state are identified based on the intelligence base simultaneously with the estimation for the first abnormality cause. (I.S.)

  12. Neuroendocrine function in survivors of childhood acute lymphocytic leukemia and non-Hodgkins lymphoma: a study of pulsatile growth hormone and gonadotropin secretions

    International Nuclear Information System (INIS)

    Mauras, N.; Sabio, H.; Rogol, A.D.

    1988-01-01

    To assess the neuroendocrine function of long-term survivors of childhood hematologic malignancies, 10 patients who had acute lymphocytic leukemia and two who had non-Hodgkins lymphoma (NHL) (mean age 13.5 +/- 1 year) were studied, who were treated with similar chemotherapeutic regimens with or without 2400 rads of prophylactic cranial irradiation. Pharmacologic growth hormone (GH) stimulation tests and three graded doses of the GH-releasing hormone (1-40-OH-GRH, 0.1, 0.3, and 1 microgram/kg) were administered. Venous sampling for GH and gonadotropin determinations was done at 20-min intervals for 24 h, and a new computerized pulse detection algorithm was used to analyze pulses. All the patients who had neuroendocrine abnormalities were in the cranially irradiated group. Two of the 12 patients were GH deficient, and had abnormal 24-h secretory profiles, blunted GH responses to pharmacologic stimuli, and minimal responses to the three doses of GRH. The pulsatile properties of luteinizing hormone (LH) were normal in 10 of the 12 nongonadally irradiated patients, irrespective of previous cranial irradiation and pubertal stage, when compared with available normative data

  13. Estimating right ventricular stroke work and the pulsatile work fraction in pulmonary hypertension.

    Science.gov (United States)

    Chemla, Denis; Castelain, Vincent; Zhu, Kaixian; Papelier, Yves; Creuzé, Nicolas; Hoette, Susana; Parent, Florence; Simonneau, Gérald; Humbert, Marc; Herve, Philippe

    2013-05-01

    The mean pulmonary artery pressure (mPAP) replaces mean systolic ejection pressure (msePAP) in the classic formula of right ventricular stroke work (RVSW) = (mPAP - RAP) × stroke volume, where RAP is mean right atrial pressure. Only the steady work is thus taken into account, not the pulsatile work, whereas pulmonary circulation is highly pulsatile. Our retrospective, high-fidelity pressure study tested the hypothesis that msePAP was proportional to mPAP, and looked at the implications for RVSW. Eleven patients with severe, precapillary pulmonary hypertension (PH) (six patients with idiopathic pulmonary arterial hypertension and five with chronic thromboembolic PH; mPAP = 57 ± 10 mm Hg) were studied at rest and during mild to moderate exercise. Eight non-PH control subjects were also studied at rest (mPAP = 16 ± 2 mm Hg). The msePAP was averaged from end diastole to dicrotic notch. In the full data set (53 pressure-flow points), mPAP ranged from 14 to 99.5 mm Hg, cardiac output from 2.38 to 11.1 L/min, and heart rate from 53 to 163 beats/min. There was a linear relationship between msePAP and mPAP (r² = 0.99). The msePAP matched 1.25 mPAP (bias, -0.5 ± 2.6 mm Hg). Results were similar in the resting non-PH group and in resting and the exercising PH group. This implies that the classic formula markedly underestimates RVSW and that the pulsatile work may be a variable 20% to 55% fraction of RVSW, depending on RAP and mPAP. At rest, RVSW in patients with PH was twice as high as that of the non-PH group (P work fraction was similar between the two groups (26 ± 4% vs 24 ± 1%) because of the counterbalancing effects of high RAP (11 ± 5 mm Hg vs 4 ± 2 mm Hg), which increases the fraction, and high mPAP, which decreases the fraction. Our study favored the use of an improved formula that takes into account the variable pulsatile work fraction: RVSW = (1.25 mPAP - RAP) × stroke volume. Increased RAP and increased mPAP have opposite effects on the pulsatile work

  14. Influence of microvascular sutures on shear strain rate in realistic pulsatile flow.

    Science.gov (United States)

    Wain, R A J; Smith, D J; Hammond, D R; Whitty, J P M

    2018-03-06

    Arterial thrombus formation is directly related to the mechanical shear experienced by platelets within flow. High shear strain rates (SSRs) and large shear gradients cause platelet activation, aggregation and production of thrombus. This study, for the first time, investigates the influence of pulsatile flow on local haemodynamics within sutured microarterial anastomoses. We measured physiological arterial waveform velocities experimentally using Doppler ultrasound velocimetry, and a representative example was applied to a realistic sutured microarterial geometry. Computational geometries were created using measurements taken from sutured chicken femoral arteries. Arterial SSRs were predicted using computational fluid dynamics (CFD) software, to indicate the potential for platelet activation, deposition and thrombus formation. Predictions of steady and sinusoidal inputs were compared to analyse whether the addition of physiological pulse characteristics affects local intravascular flow characteristics. Simulations were designed to evaluate flow in pristine and hand-sutured microarterial anastomoses, each with a steady-state and sinusoidal pulse component. The presence of sutures increased SSR max in the anastomotic region by factors of 2.1 and 2.3 in steady-state and pulsatile flows respectively, when compared to a pristine vessel. SSR values seen in these simulations are analogous to the presence of moderate arterial stenosis. Steady-state simulations, driven by a constant inflow velocity equal to the peak systolic velocity (PSV) of the measured pulsatile flow, underestimated SSRs by ∼ 9% in pristine, and ∼ 19% in sutured vessels compared with a realistic pulse. Sinusoidal flows, with equivalent frequency and amplitude to a measured arterial waveform, represent a slight improvement on steady-state simulations, but still SSRs are underestimated by 1-2%. We recommend using a measured arterial waveform, of the form presented here, for simulating pulsatile flows

  15. Chromosomal Abnormalities in ADHD

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-07-01

    Full Text Available The prevalence of fragile X syndrome, velocardiofacial syndrome (VCFS, and other cytogenetic abnormalities among 100 children (64 boys with combined type ADHD and normal intelligence was assessed at the NIMH and Georgetown University Medical Center.

  16. "Jeopardy" in Abnormal Psychology.

    Science.gov (United States)

    Keutzer, Carolin S.

    1993-01-01

    Describes the use of the board game, Jeopardy, in a college level abnormal psychology course. Finds increased student interaction and improved application of information. Reports generally favorable student evaluation of the technique. (CFR)

  17. Chromosomal abnormalities and autism

    Directory of Open Access Journals (Sweden)

    Farida El-Baz

    2016-01-01

    Conclusion: Chromosomal abnormalities were not detected in the studied autistic children, and so the relation between the genetics and autism still needs further work up with different study methods and techniques.

  18. [Evaluation of circulatory state using pulse oximeter: 2. PI (perfusion index) x PVI (pleth variability index)].

    Science.gov (United States)

    Kaneda, Toru; Suzuki, Toshiyasu

    2009-07-01

    Pulse oximeter expressed by SpO2 is used for monitoring respiratory state during operation and in ICU. Perfusion index (PI) and pleth variability index (PVI) as new indexes are calculated from pulse oximeter (Masimo SET Radical-7, Masimo Corp., USA, 1998) waveforms. And these indices were used as parameters to evaluate the circulatory state. For PI calculation, the pulsatile infrared signal is indexed against the nonpulsatile infrared signal and expressed as a percentage. It might thus be of future value in assessment of perioperative changes in peripheral perfusion. PVI is a measure of a dynamic change in PI that occurs during complete respiratory cycle. It might be thought that PVI, an index automatically derived from the pulse oximeter waveform analysis, had potentially clinical applications for noninvasive hypovolemia detection and fluid responsiveness monitoring.

  19. Abnormal sound detection device

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji.

    1995-01-01

    Only components synchronized with rotation of pumps are sampled from detected acoustic sounds, to judge the presence or absence of abnormality based on the magnitude of the synchronized components. A synchronized component sampling means can remove resonance sounds and other acoustic sounds generated at a synchronously with the rotation based on the knowledge that generated acoustic components in a normal state are a sort of resonance sounds and are not precisely synchronized with the number of rotation. On the other hand, abnormal sounds of a rotating body are often caused by compulsory force accompanying the rotation as a generation source, and the abnormal sounds can be detected by extracting only the rotation-synchronized components. Since components of normal acoustic sounds generated at present are discriminated from the detected sounds, reduction of the abnormal sounds due to a signal processing can be avoided and, as a result, abnormal sound detection sensitivity can be improved. Further, since it is adapted to discriminate the occurrence of the abnormal sound from the actually detected sounds, the other frequency components which are forecast but not generated actually are not removed, so that it is further effective for the improvement of detection sensitivity. (N.H.)

  20. Impact of the postpump resistance on pressure-flow waveform and hemodynamic energy level in a neonatal pulsatile centrifugal pump.

    Science.gov (United States)

    Wang, Shigang; Haines, Nikkole; Richardson, J Scott; Dasse, Kurt A; Undar, Akif

    2009-01-01

    This study tested the impact of different postpump resistances on pulsatile pressure-flow waveforms and hemodynamic energy output in a mock extracorporeal system. The circuit was primed with a 40% glycerin-water mixture, and a PediVAS centrifugal pump was used. The pre- and postpump pressures and flow rates were monitored via a data acquisition system. The postpump resistance was adjusted using a Hoffman clamp at the outlet of the pump. Five different postpump resistances and rotational speeds were tested with nonpulsatile (NP: 5000 RPM) and pulsatile (P: 4000 RPM) modes. No backflow was found when using pulsatile flow. With isoresistance, increased arterial resistances decreased pump flow rates (NP: from 1,912 ml/min to 373 ml/min; P: from 1,485 ml/min to 288 ml/min), increased postpump pressures (NP: from 333 mm Hg to 402 mm Hg; P: from 223 mm Hg to 274 mm Hg), and increased hemodynamic energy output with pulsatile mode. Pump flow rate correlated linearly with rotational speed (RPMs) of the pump, whereas postpump pressures and hemodynamic energy outputs showed curvilinear relationships with RPMs. The maximal pump flow rate also increased from 618 ml/min to 4,293 ml/min with pulsatile mode and from 581 ml/min to 5,665 ml/min with nonpulsatile mode. Results showed that higher postpump resistance reduced the pump flow range, and increased postpump pressure and surplus hemodynamic energy output with pulsatile mode. Higher rotational speeds also generated higher pump flow rates, postpump pressures, and increased pulsatility.

  1. Efeito do sulfato de magnésio sobre o índice de pulsatilidade das artérias uterinas, umbilical e cerebral média fetal de acordo com a persistência da incisura protodiastólica da artéria uterina na pré-eclâmpsia grave Effect of magnesium sulfate on pulsatility index of uterine, umbilical and fetal middle cerebral arteries according to the persistence of bilateral diastolic notch of uterine arteries in patients with severe preeclampsia

    Directory of Open Access Journals (Sweden)

    Alex Sandro Rolland Souza

    2009-02-01

    ção intravenosa de 6 g do sulfato de magnésio nas pacientes com pré-eclâmpsia grave, ocorre uma diminuição da pressão arterial e do IP das artérias uterinas, umbilicais e cerebral média fetal, além de aumento da frequência cardíaca materna, não influenciada pela presença de incisura protodiastólica bilateral nas artérias uterinas.PURPOSE: to evaluate the effect of magnesium sulphate on the pulsatility index (PI of the uterine, umbilical and fetal middle cerebral arteries, according to the persistency or not of the bilateral protodiastolic notch of the uterine arteries in severe pre-eclampsia. METHODS: a cohort study including 40 pregnant women with severe pre-eclampsia, 23 of them presenting bilateral protodiastolic notch, and 17, unilateral/absent notch. The patients were submitted to Doppler velocimetry before and 20 minutes after the intravenous administration of 6 g of magnesium sulphate. The examination was carried out with the patient in semi-Fowler position, the sonograms being obtained during fetal inactivity, in apnea and absent uterine contraction periods. All the exams were performed by two researchers, the average being considered as the final result. Wilcoxon's test was used to compare the PI, before and after magnesium sulphate in both groups. The difference between the two measurements (before and after magnesium sulphate was compared between the groups (bilateral incision and unilateral/absent incision using the Mann-Whitney test. RESULTS: there was a significant increase in the maternal heart rate (MHR and decrease in the maternal blood pressure, and in the PI medians of the two uterine arteries and in the fetal middle cerebral artery, after magnesium sulphate in both groups. There was a significant decrease in the PI of the left uterine artery and in the umbilical artery, only in the protodiastolic unilateral/absent notch group. Nevertheless, it was not found any significant difference regarding the PI of the right uterine artery, or the cerebral

  2. KNDy (Kisspeptin/Neurokinin B/Dynorphin) Neurons Are Activated during Both Pulsatile and Surge Secretion of LH in the Ewe

    Science.gov (United States)

    Merkley, Christina M.; Porter, Katrina L.; Coolen, Lique M.; Hileman, Stanley M.; Billings, Heather J.; Drews, Sara; Goodman, Robert L.

    2012-01-01

    KNDy (kisspeptin/neurokinin B/dynorphin) neurons of the arcuate nucleus (ARC) appear to mediate the negative feedback actions of estradiol and are thought to be key regulators of pulsatile LH secretion. In the ewe, KNDy neurons may also be involved with the positive feedback actions of estradiol (E2) to induce the LH surge, but the role of kisspeptin neurons in the preoptic area (POA) remains unclear. The goal of this study was to identify which population(s) of kisspeptin neurons is (are) activated during the LH surge and in response to the removal of E2-negative feedback, using Fos as an index of neuronal activation. Dual-label immunocytochemistry for kisspeptin and Fos was performed on sections containing the ARC and POA from ewes during the luteal phase of the estrous cycle, or before or after the onset of the LH surge (experiment 1), and from ovary-intact, short-term (24 h) and long-term (>30 d) ovariectomized (OVX) ewes in anestrus (experiment 2). The percentage of kisspeptin neurons expressing Fos in both the ARC and POA was significantly higher during the LH surge. In contrast, the percentage of kisspeptin/Fos colocalization was significantly increased in the ARC, but not POA, after both short- and long-term E2 withdrawal. Thus, POA kisspeptin neurons in the sheep are activated during, and appear to contribute to, E2-positive feedback, whereas ARC kisspeptin (KNDy) neurons are activated during both surge and pulsatile modes of secretion and likely play a role in mediating both positive and negative feedback actions of E2 on GnRH secretion in the ewe. PMID:22989631

  3. Local pulsatile PTH delivery regenerates bone defect via enhanced bone remodeling in a cell-free scaffold

    Science.gov (United States)

    Dang, Ming; Koh, Amy J.; Jin, Xiaobing; McCauley, Laurie K.; Ma, Peter X.

    2016-01-01

    Parathyroid hormone (PTH) is currently the only FDA-approved anabolic drug to treat osteoporosis, and is systemically administered through daily injections. A new local pulsatile PTH delivery device was developed from biodegradable polymers to expand PTH’s application from osteoporosis treatment to spatially controlled local bone defect regeneration in this work. This is the first time that local pulsatile PTH delivery has been demonstrated to promote bone regeneration via enhanced bone remodeling. The biodegradable delivery device was designed to locally deliver PTH in a preprogrammed pulsatile manner. The PTH delivery was utilized to facilitate the regeneration of a bone defect spatially defined with a cell-free biomimetic nanofibrous (NF) scaffold. The local pulsatile PTH delivery (daily pulse for 21 days) not only promoted the regeneration of a critical-sized bone defect with negligible systemic side effects in a mouse model, but also advantageously achieved higher quality regenerated bone than the standard systemic PTH injection. These results demonstrate a promising and novel pulsatile PTH delivery device for spatially defined local bone regeneration. PMID:27835763

  4. Local pulsatile PTH delivery regenerates bone defects via enhanced bone remodeling in a cell-free scaffold.

    Science.gov (United States)

    Dang, Ming; Koh, Amy J; Jin, Xiaobing; McCauley, Laurie K; Ma, Peter X

    2017-01-01

    Parathyroid hormone (PTH) is currently the only FDA-approved anabolic drug to treat osteoporosis, and is systemically administered through daily injections. A new local pulsatile PTH delivery device was developed from biodegradable polymers to expand the application of PTH from systemic treatment to spatially controlled local bone defect regeneration in this work. This is the first time that local pulsatile PTH delivery has been demonstrated to promote bone regeneration via enhanced bone remodeling. The biodegradable delivery device was designed to locally deliver PTH in a preprogrammed pulsatile manner. The PTH delivery was utilized to facilitate the regeneration of a bone defect spatially defined with a cell-free biomimetic nanofibrous (NF) scaffold. The local pulsatile PTH delivery (daily pulse for 21 days) not only promoted the regeneration of a critical-sized bone defect with negligible systemic side effects in a mouse model, but also advantageously achieved higher quality regenerated bone than the standard systemic PTH injection. These results demonstrate a promising and novel pulsatile PTH delivery device for spatially defined local bone regeneration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Perfusion index in preterm infants during the first 3 days of life : Reference values and relation with clinical variables

    NARCIS (Netherlands)

    Alderliesten, Thomas; Lemmers, Petra M A; Baerts, Willem; Groenendaal, Floris; Van Bel, Frank

    2015-01-01

    Background: The perfusion index (PI) derived from pulse oximetry readings represents the ratio of pulsatile (arterial blood) and nonpulsatile contributors to infrared light absorption. PI has been shown to correlate with cardiac performance. In theory, PI is readily available on every pulse

  6. Tonsillar pulsatility before and after surgical decompression for children with Chiari malformation type 1: an application for true fast imaging with steady state precession

    Energy Technology Data Exchange (ETDEWEB)

    Radmanesh, Alireza [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Washington University School of Medicine, Mallinckrodt Institute of Radiology, St Louis, MO (United States); Greenberg, Jacob K.; Smyth, Matthew D.; Limbrick, David D. [Washington University School of Medicine, Department of Neurosurgery, St Louis, MO (United States); Chatterjee, Arindam; Sharma, Aseem [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St Louis, MO (United States)

    2015-04-01

    We hypothesize that surgical decompression for Chiari malformation type 1 (CM-1) is associated with statistically significant decrease in tonsillar pulsatility and that the degree of pulsatility can be reliably assessed regardless of the experience level of the reader. An Institutional Review Board (IRB)-approved Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study was performed on 22 children with CM-1 (8 males; mean age 11.4 years) who had cardiac-gated true-FISP sequence and phase-contrast cerebrospinal fluid (CSF) flow imaging as parts of routine magnetic resonance (MR) imaging before and after surgical decompression. The surgical technique (decompression with or without duraplasty) was recorded for each patient. Three independent radiologists with different experience levels assessed tonsillar pulsatility qualitatively and quantitatively and assessed peritonsillar CSF flow qualitatively. Results were analyzed. To evaluate reliability, Fleiss kappa for multiple raters on categorical variables and intra-class correlation for agreement in pulsatility ratings were calculated. After surgical decompression, the degree of tonsillar pulsatility appreciably decreased, confirmed by t test, both qualitatively (p values <0.001, <0.001, and 0.045 for three readers) and quantitatively (amount of decrease/p value for three readers 0.7 mm/<0.001, 0.7 mm/<0.001, and 0.5 mm/0.022). There was a better agreement among the readers in quantitative assessment of tonsillar pulsatility (kappa 0.753-0.834), compared to qualitative assessment of pulsatility (kappa 0.472-0.496) and qualitative assessment of flow (kappa 0.056 to 0.203). Posterior fossa decompression with duraplasty led to a larger decrease in tonsillar pulsatility, compared to posterior fossa decompression alone. Tonsillar pulsatility in CM-1 is significantly reduced after surgical decompression. Quantitative assessment of tonsillar pulsatility was more reliable across readers than

  7. In Vitro Evaluation of ECG-Synchronized Pulsatile Flow Using the i-cor Diagonal Pump in Neonatal and Pediatric ECLS Systems.

    Science.gov (United States)

    Moroi, Morgan; Force, Madison; Wang, Shigang; Kunselman, Allen R; Ündar, Akif

    2018-02-23

    The objective was to assess the i-cor electrocardiogram-synchronized diagonal pump in terms of hemodynamic energy properties for off-label use in neonatal and pediatric extracorporeal life support (ECLS) circuits. The neonatal circuit consisted of an i-cor pump and console, a Medos Hilite 800 LT oxygenator, an 8Fr arterial cannula, a 10Fr venous cannula, 91 cm of 0.6-cm ID arterial tubing, and 91 cm of 0.6-cm ID venous tubing. The pediatric circuit was identical except it included a 12Fr arterial cannula, a 14Fr venous cannula, and a Medos Hilite 2400 LT oxygenator. Neonatal trials were conducted at 36°C with hematocrit 40% using varying flow rates (200-600 mL/min, 200 mL increments) and postarterial cannula pressures (40-100 mm Hg, 20 mm Hg increments) under nonpulsatile mode and pulsatile mode with various pulsatile amplitudes (1000-4000 rpm, 1000 rpm increments). Pediatric trials were conducted at different flow rates (800-1600 mL/min, 400 mL/min increments). Mean pressure and energy equivalent pressure increased with increasing postarterial cannula pressure, flow rate, and pulsatile amplitude. Physiologic-like pulsatility was achieved between pulsatile amplitudes of 2000-3000 rpm. Pressure drops were greatest across the arterial cannula. Pulsatile flow generated significantly higher total hemodynamic energy (THE) levels than nonpulsatile flow. THE levels at postarterial cannula site increased with increasing postarterial cannula pressure, pulsatile amplitude, and flow rate. No surplus hemodynamic energy (SHE) was generated under nonpulsatile mode. Under pulsatile mode, preoxygenator SHE increased with increasing postarterial cannula pressure and pulsatile amplitude, but decreased with increasing flow rate. The i-cor system can provide nonpulsatile and pulsatile flow for neonatal and pediatric ECLS. Pulsatile amplitudes of 2000-3000 rpm are recommended for use in neonatal and pediatric patients. © 2018 International Center for Artificial Organs and

  8. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  9. In vitro measurement of stenotic human aortic valve orifice area in a pulsatile flow model. Validation of the continuity equation.

    Science.gov (United States)

    Perakis, A C; Montarello, J K; Rosenthal, E; Boyd, E G; Yates, A K; Deverall, P B; Curry, P V; Sowton, E

    1990-06-01

    Aortic valve orifice area estimation in patients with aortic stenosis may be obtained non-invasively using several Doppler echocardiographic methods. Their validity has been established by correlation with catheterization data using the Gorlin formula, with its inherent limitations, and small discrepancies between the methods are present. To evaluate these differences further, 15 patients with severe aortic stenosis (mean transvalvular gradient 70, range 40-130 mmHg) had aortic valve area estimations by Doppler echocardiography using two variations of the continuity equation. The intact valves removed at valve replacement surgery were then mounted in a pulsatile model and the anatomical area was measured (mean 0.67 +/- 0.17 cm-2) from video recordings during flow at 5.4 l min-1. Aortic valve area calculated using the integrals of the velocity-time curves measured at the left ventricular outflow tract and aortic jet (mean 0.65 +/- 0.17 cm2) correlated best with the anatomical area (r = 0.87, P less than 0.001). The area derived by using the ratio of maximum velocities from the left ventricular outflow tract and aortic jet (mean 0.69 +/- 0.18 cm2) also correlated well with the anatomical area (r = 0.79, P less than 0.001). The index between the left ventricular outflow tract and aortic jet maximum velocities was less than or equal to 0.25 in all. In patients with severe aortic stenosis the aortic valve area can be reliably estimated using Doppler echocardiography.

  10. Pulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy

    International Nuclear Information System (INIS)

    Farzam, Parisa; Zirak, Peyman; Durduran, Turgut; Binzoni, Tiziano

    2013-01-01

    The cardiac cycle related pulsatile behavior of the absorption and scattering coefficients of diffuse light and the corresponding alterations in hemoglobin concentrations in the human patella was studied. The pulsations in scattering is considerably smaller than absorption. The difference in amplitude of absorption coefficient pulsations for different wavelengths was translated to pulsations in oxygenated and deoxygenated hemoglobin, which leads to strong pulsations in the total hemoglobin concentration and oxygen saturation. The physiological origin of the observed signals was confirmed by applying a thigh-cuff. Moreover, we have investigated the optical and physiological properties of the patella bone and their changes in response to arterial cuff occlusion. (paper)

  11. Electroresponsive polymer-carbon nanotube hydrogel hybrids for pulsatile drug delivery in vivo.

    Science.gov (United States)

    Servant, Ania; Methven, Laura; Williams, Rhodri P; Kostarelos, Kostas

    2013-06-01

    Drug release triggered by an external non-invasive stimulus is of great interest for the development of new drug delivery systems. The preparation of an electroresponsive multiwalled carbon nanotube/poly(methylacrylic acid) (MWNT/PMAA)-based hybrid material is reported. The hydrogel hybrids achieve a controlled drug release upon the ON/OFF application of an electric field, giving rise to in vitro and in vivo pulsatile release profiles. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Pulsatile Varicose Veins Secondary to Severe Tricuspid Regurgitation: Report of a Case Successfully Managed by Endovenous Laser Treatment.

    Science.gov (United States)

    Chihara, Shingo; Sawada, Kentaro; Tomoeda, Hiroshi; Aoyagi, Shigeaki

    2017-02-01

    We report a case of pulsatile varicose veins successfully managed by endovenous laser treatment (EVLT) of the great saphenous vein (GSV). A 77-year-old woman taking an anticoagulant was transferred to our hospital for pulsatile varicose veins complicated with repeated venous bleeding from an ulcer of her left lower leg. Doppler echocardiography showed severe tricuspid regurgitation, and duplex ultrasonography revealed an arterial-like pulsating flow in the saphenofemoral junction and along the GSV, but an arteriovenous fistula, obstruction of the deep veins, and the distal incompetent perforators were not detected. Because of a significant bleeding risk due to elevated venous pressure and anticoagulant therapy, EVLT was performed for the GSV, which resulted in the complete occlusion of the GSV and healing of the ulcer. EVLT presents a safe and useful therapeutic technique for pulsatile varicose veins in the limbs. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Jointly Amplified Basal and Pulsatile Growth Hormone (GH) Secretion and Increased Process Irregularity in Women with Anorexia Nervosa

    DEFF Research Database (Denmark)

    Støving, R K; Veldhuis, J D; Flyvbjerg, A

    1999-01-01

    Anorexia nervosa (AN) is associated with multiple endocrine alterations. In the majority of AN patients, basal and GHRH-stimulated serum GH levels are increased. The metabolic effects of GH are known to be related to its pulsatile secretory pattern. The present study was performed to examine GH...... mass, and burst duration were each significantly increased in women with AN compared to those in normal weight women. A 4-fold increase in daily pulsatile GH secretion was accompanied by a 20-fold increase in basal (nonpulsatile) GH secretion. There were significant negative correlations between BMI...... and the basal as well as pulsatile GH secretion rates. Moreover, AN patients exhibited significantly greater GH approximate entropy scores than the controls, denoting marked irregularity of the GH release process. In contrast to previous reports in healthy fasting subjects, cortisol levels in AN patients were...

  14. A theoretical computerized study for the electrical conductivity of arterial pulsatile blood flow by an elastic tube model.

    Science.gov (United States)

    Shen, Hua; Zhu, Yong; Qin, Kai-Rong

    2016-12-01

    The electrical conductivity of pulsatile blood flow in arteries is an important factor for the application of the electrical impedance measurement system in clinical settings. The electrical conductivity of pulsatile blood flow depends not only on blood-flow-induced red blood cell (RBC) orientation and deformation but also on artery wall motion. Numerous studies have investigated the conductivity of pulsatile blood based on a rigid tube model, in which the effects of wall motion on blood conductivity are not considered. In this study, integrating Ling and Atabek's local flow theory and Maxwell-Fricke theory, we develop an elastic tube model to explore the effects of wall motion as well as blood flow velocity on blood conductivity. The simulation results suggest that wall motion, rather than blood flow velocity, is the primary factor that affects the conductivity of flowing blood in arteries. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Nitrofurantoin and congenital abnormalities

    DEFF Research Database (Denmark)

    Czeizel, A.E.; Rockenbauer, M.; Sørensen, Henrik Toft

    2001-01-01

    Objective: To study human teratogenic potential of oral nitrofurantoin treatment during pregnancy. Materials and Methods: Pair analysis of cases with congenital abnormalities and matched population controls in the population-based dataset of the Hungarian Case-Control Surveillance of Congenital...

  16. CT of pleural abnormalities

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.)

  17. Chromosomal abnormalities and autism

    African Journals Online (AJOL)

    Farida El-Baz

    2015-06-19

    Jun 19, 2015 ... ORIGINAL ARTICLE. Chromosomal abnormalities and autism. Farida El-Baz a. , Mohamed Saad Zaghloul a. , Ezzat El Sobky a. ,. Reham M Elhossiny a,. *, Heba Salah a. , Neveen Ezy Abdelaziz b a Pediatric Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt b Children with Special ...

  18. Association between the extent of sigmoid sinus dehiscence and an occurrence of pulsatile tinnitus: a retrospective imaging study

    International Nuclear Information System (INIS)

    Dong, C.; Zhao, P.; Liu, Z.; Xu, W.; Lv, H.; Pang, S.; Wang, Z.

    2016-01-01

    Aim: To assess the extent of sigmoid sinus dehiscence (SSD) on high-resolution computed tomography venography (HRCTV) or high-resolution computed tomography (HRCT) images in pulsatile tinnitus (PT) and non-PT groups to determine whether there is an association between the extent of SSD and occurrence of PT. Materials and methods: Twenty-eight SSD patients with ipsilateral PT and 28 age- and gender-matched SSD patients without PT who underwent HRCTV or HRCT were enrolled in this study and categorised into two groups: “PT group” and “non-PT group”. The extent of SSD in each group was calculated and compared. Results: The largest transverse diameter and largest vertical diameter of SSD in the PT group were 6.21±1.7 and 6.15±2.19 mm, respectively. The largest transverse diameter and largest vertical diameter of SSD in the non-PT group were 3.06±1.38 and 2.51±1.03 mm, respectively. The extent of SSD was statistically different between the two groups (p<0.001; p<0.001). Conclusions: As a cause of PT, SSD can also occur in individuals without PT symptoms. Preliminary findings suggest that there may be a potential correlation between the extent of SSD and an occurrence of PT. - Highlights: • We compared the extent of sigmoid sinus dehiscence in pulsatile tinnitus and non-pulsatile tinnitus groups. • The sigmoid sinus dehiscence in the pulsatile tinnitus patients was larger than those in non-pulsatile tinnitus patients. • There may be a potential correlation between the extent of sigmoid sinus dehiscence and an occurrence of pulsatile tinnitus.

  19. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  20. Correlation between vortices and wall shear stress in a curved artery model under pulsatile flow conditions

    Science.gov (United States)

    Cox, Christopher; Plesniak, Michael W.

    2017-11-01

    One of the most physiologically relevant factors within the cardiovascular system is the wall shear stress. The wall shear stress affects endothelial cells via mechanotransduction and atherosclerotic regions are strongly correlated with curvature and branching in the human vasculature, where the shear stress is both oscillatory and multidirectional. Also, the combined effect of curvature and pulsatility in cardiovascular flows produces unsteady vortices. In this work, our goal is to assess the correlation between multiple vortex pairs and wall shear stress. To accomplish this, we use an in-house high-order flux reconstruction Navier-Stokes solver to simulate pulsatile flow of a Newtonian blood-analog fluid through a rigid 180° curved artery model. We use a physiologically relevant flow rate and generate results using both fully developed and uniform entrance conditions, the latter motivated by the fact that flow upstream to a curved artery may not be fully developed. Under these two inflow conditions, we characterize the evolution of various vortex pairs and their subsequent effect on several wall shear stress metrics. Supported by GW Center for Biomimetics and Bioinspired Engineering.

  1. Pulsatile growth hormone release in Turner's syndrome and short normal children.

    Science.gov (United States)

    Ghizzoni, L; Lamborghini, A; Ziveri, M; Volta, C; Panza, C; Balestrazzi, P; Bernasconi, S

    1990-09-01

    To determine whether the quantitative and qualitative aspects of GH secretion in girls with Turner's syndrome are similar to those of short-normal children we studied the 24-h GH secretion of 10 patients with Turner's syndrome and 9 short-normal children with comparable auxological features. GH profiles, obtained by 30-min sampling, were analysed by the Pulsar programme. The pulsatile GH release over the 24 h in Turner's syndrome was similar to that in normal children. However, when the GH release over the 12 day and night hours were separately analysed, only normal children showed a night-time increase in the sum of peak amplitudes. Moreover, patients with Turner's syndrome had significantly decreased number and frequency of peaks in the night-time compared with short children. In short-normal children but not in Turner's syndrome, height velocity was related to the 24-h integrated concentration of GH, area under the curve over zero-line and over baseline, sum of peak areas, and amplitudes. Night-time GH area over zero-line and over baseline, mean peak amplitude, height area, sum of peak area and amplitudes were positively correlated with height velocity in short children, whereas in Turner's syndrome height velocity was related to daytime parameters only. In conclusion, girls with Turner's syndrome have a discrete pattern of pulsatile GH release. However, the relation of GH secretion to growth in these patients, is uncertain.

  2. Anti-inflammatory effect with high intensity focused ultrasound-mediated pulsatile delivery of diclofenac.

    Science.gov (United States)

    Wang, Chih-Yu; Yang, Chih-Hui; Lin, Yung-Sheng; Chen, Chih-Hsin; Huang, Keng-Shiang

    2012-02-01

    A pulsatile ultrasound controlled drug release platform with diclofenac-loaded alginate microcapsules (fabricated with a home-made electrostatic device, 75% embedded rate) was established to evaluate anti-inflammation efficiency. Better anti-inflammation efficiency was found using the ultrasound system and the drug delivery can be adjusted based on the programmed ultrasound cycle. The results of the in vitro study show that an approx. 30% higher drug release rate was obtained by using continuous ultrasound irradiation (9-Watt, 180 min), and an approx. 16% higher drug release rate was obtained by using pulsatile ultrasound irradiation (9-Watt, 60 min) compared to without ultrasound activation. For the in vivo study, the anti-inflammatory test with carrageenan-induced rat's paw edema shows that diclofenac-loaded microcapsules followed by ultrasound irradiation (9-Watt, 60 min) contributed to an 81% inhibition rate, which was significantly higher than diclofenac only (approx. 60% higher). In addition, because of their heat conducting properties, gold nanoparticles encapsulated in the diclofenac-loaded microcapsules resulted in better drug release efficiency, but tended to depress the anti-inflammation effect. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    Energy Technology Data Exchange (ETDEWEB)

    Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in; Majee, Sreeparna

    2015-08-15

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field.

  4. The model of laminar pulsatile flow in tubes in rolling motion

    International Nuclear Information System (INIS)

    Yan, B.H.; Yu, L.; Yang, Y.H.

    2010-01-01

    The laminar pulsatile flow in tubes in rolling motion is investigated theoretically. The theoretical model of laminar flow in rolling motion is developed and the velocity correlation is also derived. The effect of rolling motion on velocity and frictional resistance factor is analyzed. The rolling motion mainly affects on the laminar flow by the tangential force. The centrifugal force does not affect on the flow. The tangential force affects on the flow in axial direction, its radial effect is very weak and could be omitted. There are two critical rolling points in rolling motion. After the first critical rolling point, the flowing velocity next to the wall reverses. Moreover, the flow rate at the tube cross-section becomes negative after the second critical rolling point. The buoyancy force is only one part of the effects that affects on the average velocity of a natural circulation system in rolling motion. The effect of Womersley number on the velocity is significant, which can not only affect on the average velocity but also on the oscillating period and velocity amplitude. The rolling motion does not affect on the average frictional resistance of laminar pulsatile flow. If the rolling motion is very serious, the flow is at a transitional or turbulent flow state, in this case the effect of rolling motion on the average frictional resistance is considerable.

  5. Biological Time Series Analysis Using a Context Free Language: Applicability to Pulsatile Hormone Data

    Science.gov (United States)

    Dean, Dennis A.; Adler, Gail K.; Nguyen, David P.; Klerman, Elizabeth B.

    2014-01-01

    We present a novel approach for analyzing biological time-series data using a context-free language (CFL) representation that allows the extraction and quantification of important features from the time-series. This representation results in Hierarchically AdaPtive (HAP) analysis, a suite of multiple complementary techniques that enable rapid analysis of data and does not require the user to set parameters. HAP analysis generates hierarchically organized parameter distributions that allow multi-scale components of the time-series to be quantified and includes a data analysis pipeline that applies recursive analyses to generate hierarchically organized results that extend traditional outcome measures such as pharmacokinetics and inter-pulse interval. Pulsicons, a novel text-based time-series representation also derived from the CFL approach, are introduced as an objective qualitative comparison nomenclature. We apply HAP to the analysis of 24 hours of frequently sampled pulsatile cortisol hormone data, which has known analysis challenges, from 14 healthy women. HAP analysis generated results in seconds and produced dozens of figures for each participant. The results quantify the observed qualitative features of cortisol data as a series of pulse clusters, each consisting of one or more embedded pulses, and identify two ultradian phenotypes in this dataset. HAP analysis is designed to be robust to individual differences and to missing data and may be applied to other pulsatile hormones. Future work can extend HAP analysis to other time-series data types, including oscillatory and other periodic physiological signals. PMID:25184442

  6. In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump.

    Science.gov (United States)

    Herreros, Jesús; Ubilla, Matías; Berjano, Enrique J; Vila-Nuñez, Juan E; Páramo, José A; Sola, Josu; Mercé, Salvador

    2010-02-01

    The aim of this study was to assess platelet dysfunction and damage to organs after extracorporeal circulation using a pump based on a new method that adds a pulsatile flow to the continuous flow provided by a centrifugal pump. The continuous component of the total flow (2-3 L/min) is created by a Bio-Pump centrifugal pump, while the pulsatile component is created by the pulsating of an inner membrane pneumatically controlled by an intra-aortic counterpulsation balloon console (systolic volume of 37.5 mL in an asynchronous way with a frequency of 60 bpm). Six pigs were subjected to a partial cardiopulmonary bypass lasting 180 min and were sacrificed 60 min after extracorporeal circulation was suspended. The hematological study included the measurement of hematocrit, hemoglobin, leukocytes, and platelet function. The new pump did not significantly alter either platelet count or platelet function. In contrast, hematocrit and hemoglobin were significantly reduced during extracorporeal circulation (approximately 5% P = 0.011, and 2 g/dL P = 0.01, respectively). The leukocyte count during extracorporeal circulation showed a tendency to decrease, but this was not significant. In general, the short-term use of the new pump (4 h) did not cause any serious morphological damage to the heart, lung, kidney, or liver. The results suggest that the hemodynamic performance of the new pump is similar to a conventional centrifugal pump and could therefore be appropriate for use in extracorporeal circulation.

  7. Computational fluid dynamics analysis and PIV validation of a bionic vortex flow pulsatile LVAD.

    Science.gov (United States)

    Xu, Liang; Yang, Ming; Ye, Lin; Dong, Zhaopeng

    2015-01-01

    Hemocompatibility is highly affected by the flow field in Left Ventricular Assistant Devices (LVAD). An asymmetric inflow and outflow channel arrangement with a 45° intersection angle with respect to the blood chamber is proposed to approximate the vascular structure of the aorta and left atrium on the left ventricle. The structure is expected to develop uninterruptible vortex flow state which is similar to the flow state in human left ventricle. The Computational Fluid Dynamics (CFD) asymmetric model is simulated using ANSYS workbench. To validate the velocity field calculated by CFD, a Particle Image Velocimetry (PIV) experiment is conducted. The CFD results show that the proposed blood chamber could generate a shifting vortex flow that would be redirected to the aorta during ejection to form a persistent recirculating flow state, which is similar to the echocardiographic flow state in left ventricle. Both the PIV and the CFD results show the development of a persistent vortex during the pulsatile period. Comparison of the qualitative flow pattern and quantitative probed velocity histories in a pulsatile period shows a good agreement between the CFD and PIV data. The goal of developing persistent quasi intra-ventricle vortex flow state in LVAD is realized.

  8. Laser Doppler anemometer measurements of pulsatile flow in a model carotid bifurcation.

    Science.gov (United States)

    Ku, D N; Giddens, D P

    1987-01-01

    Hemodynamics at the human carotid bifurcation is important to the understanding of atherosclerotic plaque initiation and progression as well as to the diagnosis of clinically important disease. Laser Doppler anemometry was performed in a large scale model of an average human carotid. Pulsatile waveforms and physiologic flow divisions were incorporated. Disturbance levels and shear stresses were computed from ensemble averages of the velocity waveform measurements. Flow in the common carotid was laminar and symmetric. Flow patterns in the sinus, however, were complex and varied considerably during the cycle. Strong helical patterns and outer wall flow separation waxed and waned during each systole. The changing flow patterns resulted in an oscillatory shear stress at the outer wall ranging from -13 to 9 dyn cm-2 during systole with a time-averaged mean of only -0.5 dyn cm-2. This contrasts markedly with an inner wall shear stress range of 17-50, (mean 26) dyn cm-2. The region of transient separation was confined to the carotid sinus outer wall with no reverse velocities detected in the distal internal carotid. Notable disturbance velocities were also time-dependent, occurring only during the deceleration phase of systole and the beginning of diastole. The present pulsatile flow studies have aided in identifying hemodynamic conditions which correlate with early intimal thickening and predict the physiologic level of flow disturbances in the bulb of undiseased internal carotid arteries.

  9. Effects of continuous and pulsatile PTH treatments on rat bone marrow stromal cells

    International Nuclear Information System (INIS)

    Yang Chiming; Frei, Hanspeter; Burt, Helen M.; Rossi, Fabio

    2009-01-01

    Bone marrow stromal cells (MSCs) differentiation and proliferation are controlled by numerous growth factors and hormones. Continuous parathyroid hormone (PTH) treatment has been shown to decrease osteoblast differentiation, whereas pulsatile PTH increases osteoblast differentiation. However, the effects of PTH treatments on MSCs have not been investigated. This study showed continuous PTH treatment in the presence of dexamethasone (DEX) promoted osteogenic differentiation of rat MSCs in vitro, as demonstrated by increased alkaline phosphatase (ALP) activity, number of ALP expressing cells, and up-regulation of PTH receptor-1, ALP, and osteocalcin mRNA expressions. In contrast, pulsatile PTH treatment was found to suppress osteogenesis of rat MSCs, possibly by promoting the maintenance of undifferentiated cells. Additionally, the observed effects of PTH were strongly dependent on the presence of DEX. MSC proliferation however was not influenced by PTH independent of treatment regimen and presence or absence of DEX. Furthermore, our work raised the possibility that PTH treatment may modulate stem/progenitor cell activity within MSC cultures.

  10. A pulsatile flow model for in vitro quantitative evaluation of prosthetic valve regurgitation

    Directory of Open Access Journals (Sweden)

    S. Giuliatti

    2000-03-01

    Full Text Available A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

  11. Neurological abnormalities predict disability

    DEFF Research Database (Denmark)

    Poggesi, Anna; Gouw, Alida; van der Flier, Wiesje

    2014-01-01

    To investigate the role of neurological abnormalities and magnetic resonance imaging (MRI) lesions in predicting global functional decline in a cohort of initially independent-living elderly subjects. The Leukoaraiosis And DISability (LADIS) Study, involving 11 European centres, was primarily aimed...... at evaluating age-related white matter changes (ARWMC) as an independent predictor of the transition to disability (according to Instrumental Activities of Daily Living scale) or death in independent elderly subjects that were followed up for 3 years. At baseline, a standardized neurological examination.......0 years, 45 % males), 327 (51.7 %) presented at the initial visit with ≥1 neurological abnormality and 242 (38 %) reached the main study outcome. Cox regression analyses, adjusting for MRI features and other determinants of functional decline, showed that the baseline presence of any neurological...

  12. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  13. Feeling Abnormal: Simulation of Deviancy in Abnormal and Exceptionality Courses.

    Science.gov (United States)

    Fernald, Charles D.

    1980-01-01

    Describes activity in which student in abnormal psychology and psychology of exceptional children classes personally experience being judged abnormal. The experience allows the students to remember relevant research, become sensitized to the feelings of individuals classified as deviant, and use caution in classifying individuals as abnormal.…

  14. Abnormal glucose tolerance and lipid abnormalities in Indian ...

    African Journals Online (AJOL)

    Discussion. Regardless of varying diagnostic classification, abnormal glucose tolerance is a well-documented risk factor. 16 Abnormalities in. Because ofthe small number offemale MI survivors, the effect of obesity and abnormal glucose tolerance on lipid levels was studied in the male patients only. There was no significant.

  15. Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices.

    Science.gov (United States)

    Medvitz, Richard B; Kreider, James W; Manning, Keefe B; Fontaine, Arnold A; Deutsch, Steven; Paterson, Eric G

    2007-01-01

    An unsteady computational fluid dynamic methodology was developed so that design analyses could be undertaken for devices such as the 50cc Penn State positive-displacement left ventricular assist device (LVAD). The piston motion observed in vitro was modeled, yielding the physiologic flow waveform observed during pulsatile experiments. Valve closure was modeled numerically by locally increasing fluid viscosity during the closed phase. Computational geometry contained Bjork-Shiley Monostrut mechanical heart valves in mitral and aortic positions. Cases for computational analysis included LVAD operation under steady-flow and pulsatile-flow conditions. Computations were validated by comparing simulation results with previously obtained in vitro particle image velocimetry (PIV) measurements. The steady portion of the analysis studied effects of mitral valve orientation, comparing the computational results with in vitro data obtained from mock circulatory loop experiments. The velocity field showed good qualitative agreement with the in vitro PIV data. The pulsatile flow simulations modeled the unsteady flow phenomena associated with a positive-displacement LVAD operating through several beat cycles. Flow velocity gradients allowed computation of the scalar wall strain rate, an important factor for determining hemodynamics of the device. Velocity magnitude contours compared well with PIV data throughout the cycle. Computational wall shear rates over the pulsatile cycle were found to be in the same range as wall shear rates observed in vitro.

  16. Multidetector CT imaging of mechanical prosthetic heart valves : quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods

  17. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias

    2011-01-01

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall

  18. Clinical Effectiveness of Centrifugal Pump to Produce Pulsatile Flow During Cardiopulmonary Bypass in Patients Undergoing Cardiac Surgery

    NARCIS (Netherlands)

    Gu, Y. John; van Oeveren, Willem; Mungroop, Hubert E.; Epema, Anne H.; den Hamer, Inez J.; Keizer, Jorrit J.; Leuvenink, Ron P.; Mariani, Massimo A.; Rakhorst, Gerhard

    Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate

  19. Pulsatile delivery of a leucine supplement during long-term continuous enteral feeding enhances lean growth in term neonatal pigs

    Science.gov (United States)

    Neonatal pigs are used as a model to study and optimize the clinical treatment of infants who are unable to maintain oral feeding. Using this model, we have previously shown that pulsatile administration of leucine during continuous feeding over 24 h via orogastric tube enhanced protein synthesis in...

  20. Pulsatile urea excretion in the ureagenic toadfish Opsanus beta: an analysis of rates and routes

    Science.gov (United States)

    Wood; Hopkins; Hogstrand; Walsh

    1995-01-01

    This study focused on the rates and routes of urea-N and ammonia-N excretion in the ureagenic toadfish and on the possibility that urea-N excretion occurs in pulses. Experimental approaches included the following: confinement in small individual containers with automated hourly sampling of water to follow temporal excretion patterns; divided chambers to separate excretion from the anterior and posterior parts of the fish; collection of urine and rectal fluid via chronic indwelling catheters; and gavage with [14C]-labelled polyethylene glycol 4000 to detect regurgitation of gastrointestinal fluids. When a standardized 'crowding' pre-treatment was employed to induce ureotelic behaviour, the fish exhibited significant elevations in the activity of glutamine synthetase in liver, kidney and gills, elevated plasma and bile urea-N levels, but unchanged ammonia-N and urea-N levels in most other body fluids. Unencumbered ureotelic fish confined in small containers excreted 82 % of their waste-N as urea-N and 18 % as ammonia-N; almost all (94 %) of this urea-N excretion occurred in a single pulse of less than 3 h duration about once every 24 h. This daily pulse did not occur by regurgitation of gut fluids, by excretion through prominent pores behind the pectoral fins or by discharge of rectal fluid or urine. Intestinal and urinary excretion accounted for less than 10 % of whole-body urea-N excretion and a negligible fraction of ammonia-N excretion. Pulsatile urea-N excretion occurred at the head end across the gills and/or body surface. Ammonia-N excretion, which was not pulsatile, also occurred largely through the head end. However, once the toadfish had been placed in divided chambers, urea-N excretion became continuous rather than pulsatile, and ammonia-N excretion increased greatly. A severe stress response was indicated by high levels of plasma cortisol, and the skin, which lacks scales, became a significant route of both ammonia-N and urea-N excretion. We speculate

  1. Exercises to Improve Gait Abnormalities

    Science.gov (United States)

    ... Articles Directories Videos Resources Contact Exercises to Improve Gait Abnormalities Home » Article Categories » Exercise and Fitness Font Size: A A A A Exercises to Improve Gait Abnormalities Next Page The manner of how a ...

  2. Prediction of low birth weight: the placental T2* estimated by MRI versus the uterine artery pulsatility index

    DEFF Research Database (Denmark)

    Sinding, Marianne Munk; Peters, David Alberg; Frøkjær, Jens Brøndum

    , Niels Uldbjerg6, Anne Sørensen1, 4 INSTITUTIONS (ALL): 1. Department of Obstetrics and Gynecology, Aalborg University Hospital, Aalborg, Denmark. 2. Department of Clinical Engineering, Central Denmark Region, Aarhus, Denmark. 3. Department of Radiology, Aalborg University Hospital, Aalborg, Denmark. 4...... was a selected, mixed population regarding the risk of low birth weight. According to our national guidelines, pregnancies with ultrasound estimated fetal weight (EFW) pregnancies at 20-40 weeks' gestation, of which 68 had an EFW ≥ -15% and 28...... using a non-linear least squares fitting algorithm. Placental T2* Z-scores were calculated using a linear regression model based on normal pregnancies previously published by our group. We defined low birth weight by a Z-score

  3. Correlation of liver enzymes and sonographic findings with pulsatile index of middle cerebral and basilar arteries in nonalcoholic fatty liver

    Directory of Open Access Journals (Sweden)

    Gholamreza Rezamand

    2014-04-01

    Conclusion: Considering the increase of cerebral arteries PI in advanced liver disease, absence of increase in vascular PI of patients in the present study could be attributed to the short duration of disease from diagnosis to perform TCD, lack of advanced liver involvement (absence of liver dysfunction and the response effect to treatment before the TCD. Therefore, to assess vascular changes over time, repeating the TCD with assess other parameters such as Fibroscan and K18 factor that has more compatibility of liver function, could help to understand the pathophysiology of liver diseases and its effect on vascular resistance.

  4. Intra- and inter-observer reproducibility and generalizability of first trimester uterine artery pulsatility index by transabdominal and transvaginal ultrasound

    NARCIS (Netherlands)

    Marchi, Laura; Zwertbroek, Eva; Snelder, Judith; Kloosterman, Maaike; Bilardo, Caterina Maddalena

    2016-01-01

    Objectives The primary aim of the study was to assess intra-observer and inter-observer reproducibility and generalizability (general reliability) of first trimester Doppler measurements of uterine arteries (UtA) performed both transabdominally (TA) and transvaginally (TV). Secondary aims were to

  5. [Penile congenital abnormalities].

    Science.gov (United States)

    Boillot, B; Teklali, Y; Moog, R; Droupy, S

    2013-07-01

    Congenital abnormalities of the penis are usually diagnosed at birth and pose aesthetic and functional problems sometimes requiring surgical management. A literature review was conducted on Medline considering the articles listed until January 2012. Hypospadias is the most common malformation (1 in 250 boys. Familial forms: 7%). The causes remain hypothetical but the doubling of the incidence in 30 years could be linked to fetal exposure to endocrine disruptors "estrogen-like" used in the food industry in particular. Surgical treatment is usually intended to improve the aesthetic appearance but sometimes, in case of significant curvature or posterior meatus, necessary for normal sexual life and fertility. Other malformations (epispades, buried penis, transpositions, twists and preputial abnormalities) as well as management for functional or aesthetic consequences of these malformations in adulthood require complex surgical care in a specialized environment. The improvement of surgical techniques and pediatric anesthesia allows an early and effective specialized surgical approach of penile malformations. Management of sequelae in adulthood must be discussed and requires experience of surgical techniques on pediatric and adult penis. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Development and Evaluation of Dual Cross-Linked Pulsatile Beads for Chronotherapy of Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Abanesh kumar Bansal

    2013-01-01

    Full Text Available In the present investigation, pulsatile release beads were prepared by ionic gelation technique. Lornoxicam dual cross-linked beads were prepared by dropping dispersed phase of lornoxicam, pectin, and sodium alginate into the dispersion phase of different concentrations of calcium chloride solution followed by aluminium chloride solution. The formulated beads were further coated by Eudragit L & S 100 in the ratio 1 : 2 w/w in order to achieve desired lag time. In vitro release study showed lag time of 5–8 h before release of lornoxicam from the formulated beads. Thus, formulated dual cross-linked beads when administered at bed time may release lornoxicam when needed most for chronotherapeutics of early morning rheumatoid arthritis attacks in chronic patients.

  7. Pulsatile lavage irrigator tip, a rare radiolucent retained foreign body in the pelvis: a case report

    Directory of Open Access Journals (Sweden)

    Archdeacon Michael T

    2011-05-01

    Full Text Available Abstract Retained foreign bodies after surgery have the potential to cause serious medical complications for patients and bring fourth serious medico-legal consequences for surgeons and hospitals. Standard operating room protocols have been adopted to reduce the occurrence of the most common retained foreign bodies. Despite these precautions, radiolucent objects and uncounted components/pieces of instruments are at risk to be retained in the surgical wound. We report the unusual case of a retained plastic pulsatile lavage irrigator tip in the surgical wound during acetabulum fracture fixation, which was subsequently identified on routine postoperative computed tomography. Revision surgery was required in order to remove the retained object, and the patient had no further complications.

  8. Implantable batteryless device for on-demand and pulsatile insulin administration

    Science.gov (United States)

    Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin

    2017-04-01

    Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.

  9. Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound

    DEFF Research Database (Denmark)

    Olesen, Jacob Bjerring; Traberg, Marie Sand; Pihl, Michael Johannes

    2013-01-01

    This paper demonstrates how pressure gradients in a pulsatile flow environment can be measured non-invasively using ultrasound. The proposed method relies on vector velocity fields acquired from ultrasound data. 2-D flow data are acquired at 18-23 frames/sec using the Transverse Oscillation...... approach. Pressure gradients are calculated from the measured velocity fields using the Navier-Stokes equation. Velocity fields are measured during constant and pulsating flow on a carotid bifurcation phantom and on a common carotid artery in-vivo. Scanning is performed with a 5 MHz BK8670 linear...... transducer using a BK Medical 2202 UltraView Pro Focus scanner. The calculated pressure gradients are validated through a finite element simulation of the constant flow model. The geometry of the flow simulation model is reproduced using MRI data, thereby providing identical flow domains in measurement...

  10. New insights into mammalian signaling pathways using microfluidic pulsatile inputs and mathematical modeling

    Science.gov (United States)

    Sumit, M.; Takayama, S.; Linderman, J. J.

    2016-01-01

    Temporally modulated input mimics physiology. This chemical communication strategy filters the biochemical noise through entrainment and phase-locking. Under laboratory conditions, it also expands the observability space for downstream responses. A combined approach involving microfluidic pulsatile stimulation and mathematical modeling has led to deciphering of hidden/unknown temporal motifs in several mammalian signaling pathways and has provided mechanistic insights, including how these motifs combine to form distinct band-pass filters and govern fate regulation under dynamic microenvironment. This approach can be utilized to understand signaling circuit architectures and to gain mechanistic insights for several other signaling systems. Potential applications include synthetic biology and biotechnology, in developing pharmaceutical interventions, and in developing lab-on-chip models. PMID:27868126

  11. New insights into mammalian signaling pathways using microfluidic pulsatile inputs and mathematical modeling.

    Science.gov (United States)

    Sumit, M; Takayama, S; Linderman, J J

    2017-01-23

    Temporally modulated input mimics physiology. This chemical communication strategy filters the biochemical noise through entrainment and phase-locking. Under laboratory conditions, it also expands the observability space for downstream responses. A combined approach involving microfluidic pulsatile stimulation and mathematical modeling has led to deciphering of hidden/unknown temporal motifs in several mammalian signaling pathways and has provided mechanistic insights, including how these motifs combine to form distinct band-pass filters and govern fate regulation under dynamic microenvironment. This approach can be utilized to understand signaling circuit architectures and to gain mechanistic insights for several other signaling systems. Potential applications include synthetic biology and biotechnology, in developing pharmaceutical interventions, and in developing lab-on-chip models.

  12. Computation of residence time in the simulation of pulsatile ventricular assist devices

    Science.gov (United States)

    Long, C. C.; Esmaily-Moghadam, M.; Marsden, A. L.; Bazilevs, Y.

    2014-10-01

    A continuum-based model of particle residence time for moving-domain fluid mechanics and fluid-structure interaction (FSI) computations is proposed, analyzed, and applied to the simulation of an adult pulsatile ventricular assist device (PVAD). Residence time is a quantity of clinical interest for blood pumps because it correlates with thrombotic risk. The proposed technique may be easily implemented in any flow or FSI solver. In the context of PVADs the results of the model may be used to assess how efficiently the pump moves the blood through its interior. Three scalar measures of particle residence time are also proposed. These scalar quantities may be used in the PVAD design with the goal of reducing thrombotic risk.

  13. A Rare Stapes Abnormality

    Directory of Open Access Journals (Sweden)

    Hala Kanona

    2015-01-01

    Full Text Available The aim of this study is to increase awareness of rare presentations, diagnostic difficulties alongside management of conductive hearing loss and ossicular abnormalities. We report the case of a 13-year-old female reporting progressive left-sided hearing loss and high resolution computed tomography was initially reported as normal. Exploratory tympanotomy revealed an absent stapedius tendon and lack of connection between the stapes superstructure and footplate. The footplate was fixed. Stapedotomy and stapes prosthesis insertion resulted in closure of the air-bone gap by 50 dB. A review of world literature was performed using MedLine. Middle ear ossicular discontinuity can result in significant conductive hearing loss. This can be managed effectively with surgery to help restore hearing. However, some patients may not be suitable or decline surgical intervention and can be managed safely conservatively.

  14. Impact of aspirin on trophoblastic invasion in women with abnormal uterine artery Doppler at 11-14 weeks: a randomized controlled study.

    Science.gov (United States)

    Scazzocchio, E; Oros, D; Diaz, D; Ramirez, J C; Ricart, M; Meler, E; González de Agüero, R; Gratacos, E; Figueras, F

    2017-04-01

    Defective trophoblastic invasion is a key feature in many cases of pre-eclampsia (PE). Uterine artery (UtA) Doppler is a validated non-invasive proxy for trophoblastic invasion. The aim of this study was to explore whether low-dose aspirin, administered from the first trimester, improves trophoblastic invasion, evaluated by UtA Doppler during the second and third trimesters in women defined as high risk by abnormal first-trimester UtA Doppler. This randomized Phase-II study had a triple-blind, parallel-arm, controlled design. Singleton pregnancies with abnormal mean UtA Doppler at 11-14 weeks and absence of other major risk factors for PE received 150 mg extended-release aspirin or identical-appearing placebo tablets from study inclusion to 28 weeks. Main outcome measure was UtA pulsatility index (PI) at 28 weeks' gestation. Secondary outcomes included frequency of development of PE and growth restriction/small-for-gestational age (SGA). A total of 155 women completed the follow-up and were analyzed. No difference in mean UtA-PI was found between women in the aspirin and placebo groups at 28 weeks (mean UtA-PI Z-score (mean ± SD), 0.99 ± 1.48 vs 0.85 ± 1.25; P = 0.52). Seven women developed PE: four (5%) in the aspirin group and three (4%) in the placebo group. There was a trend toward lower incidence of SGA in the aspirin group (8.8% vs 17.3%; P = 0.11). In women with defective trophoblastic invasion, as reflected by abnormal UtA Doppler, low-dose aspirin started in the first trimester does not have a significant effect on UtA impedance as pregnancy progresses; however, the study was underpowered to detect potential small effects . Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  15. Predictive factors for pituitary response to pulsatile GnRH therapy in patients with congenital hypogonadotropic hypogonadism.

    Science.gov (United States)

    Mao, Jiang-Feng; Wang, Xi; Zheng, Jun-Jie; Liu, Zhao-Xiang; Xu, Hong-Li; Huang, Bing-Kun; Nie, Min; Wu, Xue-Yan

    2018-03-06

    Pulsatile gonadotropin-releasing hormone (GnRH) may induce spermatogenesis in most patients with congenital hypogonadotropic hypogonadism (CHH) by stimulating gonadotropin production, while the predictors for a pituitary response to pulsatile GnRH therapy were rarely investigated. Therefore, the aim of our study is to investigate predictors of the pituitary response to pulsatile GnRH therapy. This retrospective cohort study included 82 CHH patients who received subcutaneous pulsatile GnRH therapy for at least 1 month. Patients were categorized into poor or normal luteinizing hormone (LH) response subgroups according to their LH level (LH <2 IU l -1 or LH ≥2 IU l -1 ) 1 month into pulsatile GnRH therapy. Gonadotropin and testosterone levels, testicular size, and sperm count were compared between the two subgroups before and after GnRH therapy. Among all patients, LH increased from 0.4 ± 0.5 IU l -1 to 7.5 ± 4.4 IU l -1 and follicle-stimulating hormone (FSH) increased from 1.1 ± 0.9 IU l -1 to 8.8 ± 5.3 IU l -1 . A Cox regression analysis showed that basal testosterone level (β = 0.252, P = 0.029) and triptorelin-stimulated FSH 60min (β = 0.518, P = 0.01) were two favorable predictors for pituitary response to GnRH therapy. Nine patients (9/82, 11.0%) with low LH response to GnRH therapy were classified into the poor LH response subgroup. After pulsatile GnRH therapy, total serum testosterone level was 39 ± 28 ng dl -1 versus 248 ± 158 ng dl -1 (P = 0.001), and testicular size was 4.0 ± 3.1 ml versus 7.9 ± 4.5 ml (P = 0.005) in the poor and normal LH response subgroups, respectively. It is concluded that higher levels of triptorelin-stimulated FSH 60min and basal total serum testosterone are favorable predictors of pituitary LH response to GnRH therapy.

  16. Dysglycemia induces abnormal circadian blood pressure variability

    Directory of Open Access Journals (Sweden)

    Kumarasamy Sivarajan

    2011-11-01

    Full Text Available Abstract Background Prediabetes (PreDM in asymptomatic adults is associated with abnormal circadian blood pressure variability (abnormal CBPV. Hypothesis Systemic inflammation and glycemia influence circadian blood pressure variability. Methods Dahl salt-sensitive (S rats (n = 19 after weaning were fed either an American (AD or a standard (SD diet. The AD (high-glycemic-index, high-fat simulated customary human diet, provided daily overabundant calories which over time lead to body weight gain. The SD (low-glycemic-index, low-fat mirrored desirable balanced human diet for maintaining body weight. Body weight and serum concentrations for fasting glucose (FG, adipokines (leptin and adiponectin, and proinflammatory cytokines [monocyte chemoattractant protein-1 (MCP-1 and tumor necrosis factor-α (TNF-α] were measured. Rats were surgically implanted with C40 transmitters and blood pressure (BP-both systolic; SBP and diastolic; DBP and heart rate (HR were recorded by telemetry every 5 minutes during both sleep (day and active (night periods. Pulse pressure (PP was calculated (PP = SBP-DBP. Results [mean(SEM]: The AD fed group displayed significant increase in body weight (after 90 days; p Conclusion These data validate our stated hypothesis that systemic inflammation and glycemia influence circadian blood pressure variability. This study, for the first time, demonstrates a cause and effect relationship between caloric excess, enhanced systemic inflammation, dysglycemia, loss of blood pressure control and abnormal CBPV. Our results provide the fundamental basis for examining the relationship between dysglycemia and perturbation of the underlying mechanisms (adipose tissue dysfunction induced local and systemic inflammation, insulin resistance and alteration of adipose tissue precursors for the renin-aldosterone-angiotensin system which generate abnormal CBPV.

  17. A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra Hl-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model.

    Science.gov (United States)

    Ressler, Noel; Rider, Alan R; Kunselman, Allen R; Richardson, J Scott; Dasse, Kurt A; Wang, Shigang; Undar, Akif

    2009-01-01

    The hemodynamic comparison of the Jostra HL-20 and the Levitronix PediVAS blood pumps is the focus this study, where pressure-flow waveforms and hemodynamic energy values are analyzed in the confines of a pediatric cardiopulmonary bypass circuit.The pseudo pediatric patient was perfused with flow rates between 500 and 900 ml/min (100 ml/min increments) under pulsatile and nonpulsatile mode. The Levitronix continuous flow pump utilized a customized controller to engage in pulsatile perfusion with equivalent pulse settings to the Jostra HL-20 roller pump. Hemodynamic measurements and waveforms were recorded at the precannula location, while the mean arterial pressure was maintained at 40 mm Hg for each test. Glycerin water was used as the blood analog circuit perfusate. At each flow rate 24 trials were conducted yielding a total of 120 experiments (n=60 pulsatile and n=60 nonpulsatile).Under nonpulsatile perfusion the Jostra roller pump produced small values for surplus hemodynamic energy (SHE) due to its inherent pulsatility, while the Levitronix produced values of essentially zero for SHE. When switching to pulsatile perfusion, the SHE levels for both the Jostra and Levitronix pump made considerable increases. In comparing the two pumps under pulsatile perfusion, the Levitronix PediVAS produced significantly more surplus and total hemodynamic energy than did the Jostra roller pump each pump flow rate.The study suggests that the Levitronix PediVAS centrifugal pump has the capability of achieving quality pulsatile waveforms and delivering more SHE to the pseudo patient than the Jostra HL-20 roller pump. Further studies are warranted to investigate the Levitronix under bovine blood studies and with various pulsatile settings.

  18. Abnormal portal vein waveform as an indicator of constrictive pericarditis – a case report

    Directory of Open Access Journals (Sweden)

    Joanna Ścieszka

    2015-06-01

    Full Text Available We report a case of a 17-year-old patient referred to our outpatient Doppler Department due to clinical suspicion of liver cirrhosis. The patient presented with non-specifi c symptoms, such as malaise, pain in the right subcostal region, peripheral oedema. Until then, diagnostic imaging, including echocardiography was inconclusive. We performed the Doppler sonography of the portal system, which revealed normal diameter of the portal vein with abnormal, phasic and markedly pulsatile waveform. Hepatic veins distention with pathological reverse fl ow during systole was reported. Additionally, inferior vena cava was dilated and remained unchanged through the respiratory cycle. Basing on the above image a heart disease, which had not been taken into differential diagnosis before, was suggested. The following echocardiography, together with computed tomography, enabled a diagnosis of constrictive pericarditis. Successful pericardiotomy was performed. Such a complicated diagnostics happened to demonstrate an uncommon example of the use of portal vein waveform in making the proper cardiologic diagnosis.

  19. Comparing the speed of irrigation between pulsatile lavage versus gravity irrigation: an Ex-vivo experimental investigation

    OpenAIRE

    Mundy, Lily R.; Gage, Mark J.; Yoon, Richard S.; Liporace, Frank A.

    2017-01-01

    Background The need for reoperation or wound infection treatments between pulsatile and gravity irrigation are statistically equivalent, however, it is unclear which method maximizes operative efficiency and expeditious irrigation. In this study we set out to determine the differences in irrigation rate between these various treatment methods. Methods This was an ex-vivo experimental laboratory study not involving human subjects. Irrigation rates were tested based on the time in seconds requi...

  20. Flow Visualization of Three-Dimensionality Inside the 12 cc Penn State Pulsatile Pediatric Ventricular Assist Device

    OpenAIRE

    Roszelle, Breigh N.; Deutsch, Steven; Manning, Keefe B.

    2010-01-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV...

  1. [Spermatogenesis of pulsatile gonadotropin-releasing hormone infusion versus gonadotropin therapy in male idiopathic hypogonadotropic hypogonadism].

    Science.gov (United States)

    Huang, Bingkun; Mao, Jiangfeng; Xu, Hongli; Wang, Xi; Liu, Zhaoxiang; Nie, Min; Wu, Xueyan

    2015-05-26

    To compare the efficacies of pulsatile gonadotropin-releasing hormone (GnRH) versus human chorionic gonadotropin/human menopausal gonadotropin (HCG/HMG) for spermatogenesis in male idiopathic hypogonadotropic hypogonadism (IHH). For this retrospective study, a total of 92 male IHH outpatients from May 2010 to October 2014 were recruited and categorized into GnRH (n = 40) and HCG/HMG (n = 52) groups. Each subject selected one specific therapy voluntarily. The gonadotropin levels were measured in the first week and monthly post-treatment in GnRH group. And serum total testosterone (TT), testicular volume (TV) and rate of spermatogenesis were observed monthly post-treatment in two groups. Spermatogenesis, TT and TV were compared between two groups. All IHH patients were treated for over 3 months. The median follow-up periods in GnRH and HCG/HMG groups was 8.2 (3.0-18.4) and 9.2 (3.0-18.6) months respectively (P = 0.413). In GnRH group, LH ((0.5 ± 0.6) vs (3.4 ± 2.4) U/L, P < 0.01) and FSH ((1.3 ± 1.1) vs (5.8 ± 3.8) U/L, P < 0.01) increased after 1-week treatment. In GnRH group, at the end of follow-up, TT ((1.0 ± 1.0) vs (7.4 ± 5.2) nmol/L, P < 0.01) and TV ((2.3 ± 1.5) vs (8.1 ± 4.0) ml, P < 0.01) significantly increased compared to baseline. In HCG/HMG group, TT ((0.8 ± 0.6) vs (14.4 ± 8.0) nmol/L, P < 0.01) and TV ((2.3 ± 2.1) vs (7.6 ± 4.2) ml, P < 0.01) significantly increased after therapy. The success rate of spermatogenesis was 50.0% (20/40) in GnRH group versus 28.8% (15/52) in HCG/HMG group (P = 0.038). GnRH group required a shorter treatment time for initial sperm appearance than HCG/HMG group ((6.5 ± 3.1) vs (10.8 ± 3.7) months, P = 0.001). Pulsatile GnRH requires a shorter time for initiation of spermatogenesis than gonadotropin therapy in IHH male patients.

  2. Computational Fluid Dynamics Simulation of Hemodynamic Alterations in Sigmoid Sinus Diverticulum and Ipsilateral Upstream Sinus Stenosis After Stent Implantation in Patients with Pulsatile Tinnitus.

    Science.gov (United States)

    Han, Yanjing; Yang, Qingqing; Yang, Zeran; Xia, Jun; Su, Tianhao; Yu, Jianan; Jin, Long; Qiao, Aike

    2017-10-01

    To investigate the relationships between upstream venous sinus stenosis and pulsatile tinnitus (PT), and to assess the correlation with diverticulum growth and the effectiveness of stent implantation. Patient-specific geometric models were constructed using computed tomography venography images from a patient with PT, with sigmoid sinus diverticulum, and with upstream transverse sinus stenosis, in whom stenting of the upstream sinus stenosis alone achieved complete remission of PT. Computational fluid dynamics simulation based on this patient-specific geometry was performed using commercially available finite element software (ANSYS-14) to qualitatively and quantitatively compare the flow velocity, flow rate, velocity vector, pressure, vorticity, and wall shear stress on the affected side transverse and sigmoid sinuses, before and after stent implantation. Stenting improved the flow direction and magnitude. After stenting, the flow pattern became smoother and more regular. High-speed blood flow at the level of the diverticulum neck was confined to a smaller area, and its direction changed from approximately perpendicular to the diverticular dome to the distal side of the diverticular neck. The diverticulum showed obvious flow reduction, with decreases of 80.7%, 68.7%, 96.1%, and 91.3% in peak velocity, inflow rate, pressure gradient, and peak vorticity, respectively. The abnormally low wall shear stress at the dome of diverticulum was eliminated. Our findings strongly support a major role of diverticulum stenosis before in PT development and suggest that such stenosis is a causative factor of diverticulum growth. They also confirm the effectiveness of stent implantation for the treatment of PT. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Pulsatile flow and mass transport over an array of cylinders: gas transfer in a cardiac-driven artificial lung.

    Science.gov (United States)

    Chan, Kit Yan; Fujioka, Hideki; Bartlett, Robert H; Hirschl, Ronald B; Grotberg, James B

    2006-02-01

    The pulsatile flow and gas transport of a Newtonian passive fluid across an array of cylindrical microfibers are numerically investigated. It is related to an implantable, artificial lung where the blood flow is driven by the right heart. The fibers are modeled as either squared or staggered arrays. The pulsatile flow inputs considered in this study are a steady flow with a sinusoidal perturbation and a cardiac flow. The aims of this study are twofold: identifying favorable array geometry/spacing and system conditions that enhance gas transport; and providing pressure drop data that indicate the degree of flow resistance or the demand on the right heart in driving the flow through the fiber bundle. The results show that pulsatile flow improves the gas transfer to the fluid compared to steady flow. The degree of enhancement is found to be significant when the oscillation frequency is large, when the void fraction of the fiber bundle is decreased, and when the Reynolds number is increased; the use of a cardiac flow input can also improve gas transfer. In terms of array geometry, the staggered array gives both a better gas transfer per fiber (for relatively large void fraction) and a smaller pressure drop (for all cases). For most cases shown, an increase in gas transfer is accompanied by a higher pressure drop required to power the flow through the device.

  4. Local pulsatile contractions are an intrinsic property of the myosin 2A motor in the cortical cytoskeleton of adherent cells

    Science.gov (United States)

    Baird, Michelle A.; Billington, Neil; Wang, Aibing; Adelstein, Robert S.; Sellers, James R.; Fischer, Robert S.; Waterman, Clare M.

    2017-01-01

    The role of nonmuscle myosin 2 (NM2) pulsatile dynamics in generating contractile forces required for developmental morphogenesis has been characterized, but whether these pulsatile contractions are an intrinsic property of all actomyosin networks is not known. Here we used live-cell fluorescence imaging to show that transient, local assembly of NM2A “pulses” occurs in the cortical cytoskeleton of single adherent cells of mesenchymal, epithelial, and sarcoma origin, independent of developmental signaling cues and cell–cell or cell–ECM interactions. We show that pulses in the cortical cytoskeleton require Rho-associated kinase– or myosin light chain kinase (MLCK) activity, increases in cytosolic calcium, and NM2 ATPase activity. Surprisingly, we find that cortical cytoskeleton pulses specifically require the head domain of NM2A, as they do not occur with either NM2B or a 2B-head-2A-tail chimera. Our results thus suggest that pulsatile contractions in the cortical cytoskeleton are an intrinsic property of the NM2A motor that may mediate its role in homeostatic maintenance of tension in the cortical cytoskeleton of adherent cells. PMID:27881665

  5. Glucose uptake and pulsatile insulin infusion: euglycaemic clamp and [3-3H]glucose studies in healthy subjects

    International Nuclear Information System (INIS)

    Schmitz, O.; Arnfred, J.; Hother Nielsen, O.; Beck-Nielsen, H.; Oerskov, H.

    1986-01-01

    To test the hypothesis that insulin has a greater effect on glucose metabolism when given as pulsatile than as continuous infusion, a 354-min euglycaemic clamp study was carried out in 8 healthy subjects. At random order soluble insulin was given intravenously either at a constant rate of 0.45mU/kg · min or in identical amounts in pulses of 1 1 / 2 to 2 1 / 4 min followed by intervals of 10 1 / 2 to 9 3 / 4 min. Average serum insulin levels were similar during the two infusion protocols, but pulsatile administration induced oscillations ranging between 15 and 62 μU/ml. Glucose uptake expressed as metabolic clearance rate (MCR) for glucose was significantly increased during pulsatile insulin delivery as compared with continuous administration (270-294 min: 8.7±0.7 vs 6.8±0.9 ml/kg · min, P 3 H]glucose infusion technique was suppressed to insignificant values. Finally, the effect of insulin on endogenous insulin secretion and lipolysis as assessed by changes in serum C-peptide and serum FFA was uninfluenced by the infusion mode. In conclusion, insulin infusion resulting in physiological serum insulin levels enhances glucose uptake in peripheral tissues in healthy subjects to a higher degree when given in a pulsed pattern mimicking that of the normal endocrine pancreas than when given as a continuous infusion. (author)

  6. Local pulsatile contractions are an intrinsic property of the myosin 2A motor in the cortical cytoskeleton of adherent cells.

    Science.gov (United States)

    Baird, Michelle A; Billington, Neil; Wang, Aibing; Adelstein, Robert S; Sellers, James R; Fischer, Robert S; Waterman, Clare M

    2017-01-15

    The role of nonmuscle myosin 2 (NM2) pulsatile dynamics in generating contractile forces required for developmental morphogenesis has been characterized, but whether these pulsatile contractions are an intrinsic property of all actomyosin networks is not known. Here we used live-cell fluorescence imaging to show that transient, local assembly of NM2A "pulses" occurs in the cortical cytoskeleton of single adherent cells of mesenchymal, epithelial, and sarcoma origin, independent of developmental signaling cues and cell-cell or cell-ECM interactions. We show that pulses in the cortical cytoskeleton require Rho-associated kinase- or myosin light chain kinase (MLCK) activity, increases in cytosolic calcium, and NM2 ATPase activity. Surprisingly, we find that cortical cytoskeleton pulses specifically require the head domain of NM2A, as they do not occur with either NM2B or a 2B-head-2A-tail chimera. Our results thus suggest that pulsatile contractions in the cortical cytoskeleton are an intrinsic property of the NM2A motor that may mediate its role in homeostatic maintenance of tension in the cortical cytoskeleton of adherent cells. © 2017 Baird et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  7. Abnormal pressure in hydrocarbon environments

    Science.gov (United States)

    Law, B.E.; Spencer, C.W.

    1998-01-01

    Abnormal pressures, pressures above or below hydrostatic pressures, occur on all continents in a wide range of geological conditions. According to a survey of published literature on abnormal pressures, compaction disequilibrium and hydrocarbon generation are the two most commonly cited causes of abnormally high pressure in petroleum provinces. In young (Tertiary) deltaic sequences, compaction disequilibrium is the dominant cause of abnormal pressure. In older (pre-Tertiary) lithified rocks, hydrocarbon generation, aquathermal expansion, and tectonics are most often cited as the causes of abnormal pressure. The association of abnormal pressures with hydrocarbon accumulations is statistically significant. Within abnormally pressured reservoirs, empirical evidence indicates that the bulk of economically recoverable oil and gas occurs in reservoirs with pressure gradients less than 0.75 psi/ft (17.4 kPa/m) and there is very little production potential from reservoirs that exceed 0.85 psi/ft (19.6 kPa/m). Abnormally pressured rocks are also commonly associated with unconventional gas accumulations where the pressuring phase is gas of either a thermal or microbial origin. In underpressured, thermally mature rocks, the affected reservoirs have most often experienced a significant cooling history and probably evolved from an originally overpressured system.

  8. Computational Fluid Dynamics Analysis of Pulsatile Blood Flow Behavior in Modelled Stenosed Vessels with Different Severities

    Directory of Open Access Journals (Sweden)

    Mohsen Mehrabi

    2012-01-01

    Full Text Available This study focuses on the behavior of blood flow in the stenosed vessels. Blood is modelled as an incompressible non-Newtonian fluid which is based on the power law viscosity model. A numerical technique based on the finite difference method is developed to simulate the blood flow taking into account the transient periodic behaviour of the blood flow in cardiac cycles. Also, pulsatile blood flow in the stenosed vessel is based on the Womersley model, and fluid flow in the lumen region is governed by the continuity equation and the Navier-Stokes equations. In this study, the stenosis shape is cosine by using Tu and Devil model. Comparing the results obtained from three stenosed vessels with 30%, 50%, and 75% area severity, we find that higher percent-area severity of stenosis leads to higher extrapressure jumps and higher blood speeds around the stenosis site. Also, we observe that the size of the stenosis in stenosed vessels does influence the blood flow. A little change on the cross-sectional value makes vast change on the blood flow rate. This simulation helps the people working in the field of physiological fluid dynamics as well as the medical practitioners.

  9. A Novel Pulsatile Bioreactor for Mechanical Stimulation of Tissue Engineered Cardiac Constructs

    Directory of Open Access Journals (Sweden)

    Günther Eissner

    2011-07-01

    Full Text Available After myocardial infarction, the implantation of stem cell seeded scaffolds on the ischemic zone represents a promising strategy for restoration of heart function. However, mechanical integrity and functionality of tissue engineered constructs need to be determined prior to implantation. Therefore, in this study a novel pulsatile bioreactor mimicking the myocardial contraction was developed to analyze the behavior of mesenchymal stem cells derived from umbilical cord tissue (UCMSC colonized on titanium-coated polytetrafluorethylene scaffolds to friction stress. The design of the bioreactor enables a simple handling and defined mechanical forces on three seeded scaffolds at physiological conditions. The compact system made of acrylic glass, Teflon®, silicone, and stainless steel allows the comparison of different media, cells and scaffolds. The bioreactor can be gas sterilized and actuated in a standard incubator. Macroscopic observations and pressure-measurements showed a uniformly sinusoidal pulsation, indicating that the bioreactor performed well. Preliminary experiments to determine the adherence rate and morphology of UCMSC after mechanical loadings showed an almost confluent cellular coating without damage on the cell surface. In summary, the bioreactor is an adequate tool for the mechanical stress of seeded scaffolds and offers dynamic stimuli for pre-conditioning of cardiac tissue engineered constructs in vitro.

  10. Dynamic time warping and machine learning for signal quality assessment of pulsatile signals

    International Nuclear Information System (INIS)

    Li, Q; Clifford, G D

    2012-01-01

    In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal. (paper)

  11. Bioavailability assessment of hydroxymethylglutaryl coenzyme A reductase inhibitor utilizing pulsatile drug delivery system: a pilot study.

    Science.gov (United States)

    Taha, Ehab I

    2016-09-01

    Chronotherapy or pulsatile drug delivery system could be achieved by increasing drug plasma concentration exactly at the time of disease incidence. Cholesterol synthesis shows a circadian rhythm being high at late night and early in the morning. Simvastatin (SIM) inhibits hydroxymethylglutaryl coenzyme A reductase, which is responsible for cholesterol synthesis. In this study, SIM lipid-based formulation filled in gelatin capsules and coated with aqueous Eudragit® S100 dispersion was prepared for chronotherapeutic treatment of hypercholesterolemia. The pharmacokinetic parameters of SIM capsules were studied in human volunteers after a single oral dose and compared with that of Zocor® tablets as a reference in a randomized cross-over study. Pharmacokinetic parameters such as AUC 0-∞ , C max , T max , t 1/2 and elimination rate constant were determined from plasma concentration-time profile for both formulations. The tested formulation had the ability to delay drug absorption and provide higher drug concentrations from 3 up to 10 h after oral administration compared to that of commercial tablets. The data in this study revealed that the prepared formulation could be effective in chronotherapeutic treatment of hypercholesterolemia. Moreover, the tested formulation was found to enhance SIM bioavailability by 29% over the reference tablets.

  12. Injection-molded capsular device for oral pulsatile release: development of a novel mold.

    Science.gov (United States)

    Zema, Lucia; Loreti, Giulia; Macchi, Elena; Foppoli, Anastasia; Maroni, Alessandra; Gazzaniga, Andrea

    2013-02-01

    The development of a purposely devised mold and a newly set up injection molding (IM) manufacturing process was undertaken to prepare swellable/erodible hydroxypropyl cellulose-based capsular containers. When orally administered, such devices would be intended to achieve pulsatile and/or colonic time-dependent delivery of drugs. An in-depth evaluation of thermal, rheological, and mechanical characteristics of melt formulations/molded items made of the selected polymer (Klucel® LF) with increasing amounts of plasticizer (polyethylene glycol 1500, 5%-15% by weight) was preliminarily carried out. On the basis of the results obtained, a new mold was designed that allowed, through an automatic manufacturing cycle of 5 s duration, matching cap and body items to be prepared. These were subsequently filled and coupled to give a closed device of constant 600 μm thickness. As compared with previous IM systems having the same composition, such capsules showed improved closure mechanism, technological properties, especially in terms of reproducibility of the shell thickness, and release performance. Moreover, the ability of the capsular container to impart a constant lag phase before the liberation of the contents was demonstrated irrespective of the conveyed formulation. Copyright © 2012 Wiley Periodicals, Inc.

  13. A Pulsatile Bioreactor for Conditioning of Tissue-Engineered Cardiovascular Constructs under Endoscopic Visualization

    Directory of Open Access Journals (Sweden)

    Bassil Akra

    2012-07-01

    Full Text Available Heart valve disease (HVD is a globally increasing problem and accounts for thousands of deaths yearly. Currently end-stage HVD can only be treated by total valve replacement, however with major drawbacks. To overcome the limitations of conventional substitutes, a new clinical approach based on cell colonization of artificially manufactured heart valves has been developed. Even though this attempt seems promising, a confluent and stable cell layer has not yet been achieved due to the high stresses present in this area of the human heart. This study describes a bioreactor with a new approach to cell conditioning of tissue engineered heart valves. The bioreactor provides a low pulsatile flow that grants the correct opening and closing of the valve without high shear stresses. The flow rate can be regulated allowing a steady and sensitive conditioning process. Furthermore, the correct functioning of the valve can be monitored by endoscope surveillance in real-time. The tubeless and modular design allows an accurate, simple and faultless assembly of the reactor in a laminar flow chamber. It can be concluded that the bioreactor provides a strong tool for dynamic pre-conditioning and monitoring of colonized heart valve prostheses physiologically exposed to shear stress.

  14. Numerical investigation of flow parameters for solid rigid spheroidal particle in a pulsatile pipe flow

    Science.gov (United States)

    Varghese, Joffin; Jayakumar, J. S.

    2017-09-01

    Quantifying, forecasting and analysing the displacement rates of suspended particles are essential while discussing about blood flow analysis. Because blood is one of the major organs in the body, which enables transport phenomena, comprising of numerous blood cells. In order to model the blood flow, a flow domain was created and numerically simulated. Flow field velocity in the stream is solved utilizing Finite Volume Method utilizing FVM unstructured solver. In pulsatile flow, the effect of parameters such as average Reynolds number, tube radius, particle size and Womersley number are taken into account. In this study spheroidal particle trajectory in axial direction is simulated at different values of pulsating frequency including 1.2 Hz, 3.33 Hz and 4.00 Hz and various densities including 1005 kg/m3 and 1025 kg/m3 for the flow domain. The analysis accomplishes the interaction study of blood constituents for different flow situations which have applications in diagnosis and treatment of cardio vascular related diseases.

  15. Shape optimization of pulsatile ventricular assist devices using FSI to minimize thrombotic risk

    Science.gov (United States)

    Long, C. C.; Marsden, A. L.; Bazilevs, Y.

    2014-10-01

    In this paper we perform shape optimization of a pediatric pulsatile ventricular assist device (PVAD). The device simulation is carried out using fluid-structure interaction (FSI) modeling techniques within a computational framework that combines FEM for fluid mechanics and isogeometric analysis for structural mechanics modeling. The PVAD FSI simulations are performed under realistic conditions (i.e., flow speeds, pressure levels, boundary conditions, etc.), and account for the interaction of air, blood, and a thin structural membrane separating the two fluid subdomains. The shape optimization study is designed to reduce thrombotic risk, a major clinical problem in PVADs. Thrombotic risk is quantified in terms of particle residence time in the device blood chamber. Methods to compute particle residence time in the context of moving spatial domains are presented in a companion paper published in the same issue (Comput Mech, doi: 10.1007/s00466-013-0931-y, 2013). The surrogate management framework, a derivative-free pattern search optimization method that relies on surrogates for increased efficiency, is employed in this work. For the optimization study shown here, particle residence time is used to define a suitable cost or objective function, while four adjustable design optimization parameters are used to define the device geometry. The FSI-based optimization framework is implemented in a parallel computing environment, and deployed with minimal user intervention. Using five SEARCH/ POLL steps the optimization scheme identifies a PVAD design with significantly better throughput efficiency than the original device.

  16. Deformation of a membrane in a pulsatile flow: implications in heart valve design

    Science.gov (United States)

    Hernandez, C.; Guzman, J. E. V.; Zenit, R.

    2011-11-01

    Current designs of heart valves prosthetics have serious disadvantages and health issues for patients who use them. For this reason, a new design that combines durability (mechanical valves) and biocompatibility (biological valves) has to be conceived. Natural valves have very complex geometry because their leaflets have two principal curvatures, one imposed by the holding ring and a second one imposed by the bending of the closing arrangement. The objective of this research is to study the effects of both curvatures on the performance of a leaflet. It is well known that the increase of the curvature results in a larger stiffness, which, in turn, reduces the deflection of a leaflet. We conducted a study to determine the effect of changing the curvature (in two directions) of a flexible membrane when exposed to a steady and pulsatile flows. A study of the flow field that results from this interaction is also conducted by PIV measurements. Preliminary results of the leaflet deflection for many stiffnesses, curvatures and flow conditions will be presented and discussed.

  17. Afghanistan Index

    DEFF Research Database (Denmark)

    Linnet, Poul Martin

    2007-01-01

    The Afghanistan index is a compilation of quantitative and qualitative data on the reconstruction and security effort in Afghanistan. The index aims at providing data for benchmarking of the international performance and thus provides the reader with a quick possibility to retrieve valid...... information on progress or lack of progress in the reconstruction of the post Taliban Afghanistan. The index is mainly based on information collected on the internet in order to provide quick access to the original source. The index is under development and thus new information will be added on a continuous...

  18. Persistent Abnormal Coronary Flow Reserve in Association with Abnormal Glucose Metabolism Affects Prognosis in Acute Myocardial Infarction

    DEFF Research Database (Denmark)

    Løgstrup, Brian B; Høfsten, Dan E; Christophersen, Thomas B

    2011-01-01

    Objectives: To evaluate changes in coronary flow reserve (CFR) over time after acute myocardial infarction (AMI) in relation to left ventricular (LV) function and glucometabolic state and prognostic implication of abnormal CFR. Methods: 154 patients with first time AMI had a comprehensive...... assessment of the LV function and CFR at baseline and after 3 months of follow-up. CFR was measured noninvasively in left descending artery by transthoracic echocardiography. Results: Eighty-five patients had an abnormal CFR at baseline. At baseline patients with persistently normal CFR had higher wall...... motion score index (WMI), ejection fraction (EF) and S' compared with patients with abnormal CFR. At follow-up patients with persistently normal CFR had higher WMI, EF, S' and lower end-systolic diameter compared with patients with abnormal microcirculation. Performing univariate logistical regression...

  19. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

    Directory of Open Access Journals (Sweden)

    Donald P Bernstein

    2010-01-01

    Full Text Available Impedance cardiography (ICG is a branch of bioimpedance pimarily concerned with the determination of left ventricular stroke volume (SV. As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC. By Ohm's Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω. Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ΔZ(t, which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t. ΔZ(t represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ΔZ(t is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ΔZ(t, (i.e. dZ/dtmax, with the presumed units of Ω·s-1. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (Δρb(t, Ωcm·s-1, and it is the peak rate of change of the blood resistivity variation dρb(t/dtmax (Ωcm·s-2 that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s-2, it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s-2 and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s-2

  20. AP Index

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Planetary Amplitude index - Bartels 1951. The a-index ranges from 0 to 400 and represents a K-value converted to a linear scale in gammas (nanoTeslas)--a scale that...

  1. Somatosensory abnormalities in knee OA.

    Science.gov (United States)

    Wylde, Vikki; Palmer, Shea; Learmonth, Ian D; Dieppe, Paul

    2012-03-01

    The aim of this study was to use quantitative sensory testing (QST) to explore the range and prevalence of somatosensory abnormalities demonstrated by patients with advanced knee OA. One hundred and seven knee OA patients and 50 age- and sex-matched healthy participants attended a 1-h QST session. Testing was performed on the medial side of the knee and the pain-free forearm. Light-touch thresholds were assessed using von Frey filaments, pressure pain thresholds using a digital pressure algometer, and thermal sensation and pain thresholds using a Thermotest MSA. Significant differences in median threshold values from knee OA patients and healthy participants were identified using Mann-Whitney U-tests. The z-score transformations were used to determine the prevalence of the different somatosensory abnormalities in knee OA patients. Testing identified 70% of knee OA patients as having at least one somatosensory abnormality. Comparison of median threshold values between knee OA patients and healthy participants revealed that patients had localized thermal and tactile hypoaesthesia and pressure hyperalgesia at the osteoarthritic knee. Tactile hypoaesthesia and pressure hyperalgesia were also present at the pain-free forearm. The most prevalent somatosensory abnormalities were tactile hypoaesthesia and pressure hyperalgesia, evident in between 20 and 34% of patients. This study found that OA patients demonstrate an array of somatosensory abnormalities, of which the most prevalent were tactile hypoaesthesia and pressure hyperalgesia. Further research is now needed to establish the clinical implications of these somatosensory abnormalities.

  2. Pulsatile flow of cerebrospinal fluid on magnetic resonance images and its relation to intracranial pressure

    International Nuclear Information System (INIS)

    Ohara, Shigeki

    1988-01-01

    In a retrospective study of the magnetic resonance (MR) images of 289 neurosurgical patients, loss of signal intensity (the signal void phenomenon) of cerebrospinal fluid (CSF) in the mesencephalic aqueduct was observed in 77 patients. This signal void phenomenon (SVP) was seen most frequently in patients suffering from communicating hydrocephalus (12 of 14), less frequently in patients with supratentorial tumors (7 of 50), and not at all in patients with noncommunicating hydrocephalus (none of 9). Eight of 19 patients with infratentorial lesions who did not demonstrate the SVP preoperatively, developed it after suboccipital craniectomy. It is known that CSF in the cranial cavity flows toward the spinal CSF space in a to and fro manner in response to the pulsations of the brain. The velocity of this flow is faster in the narrower parts in the ventricular system such as the aqueduct, Monro's foramen and the fourth ventricle. The SVP reflects CSF pulsatile flow forced out of the intracranial space into the intraspinal space by the brain's pulsations. The SVP was observed frequently in the MR images of patients with communicating hydrocephalus who showed normal intracranial mean pressure (mICP) and normal pulse pressure (PP), whereas the SVP was observed rarely in patients with high mICP and high PP, such as those with a supratentorial tumor. The SVP may reflect the capacity of the craniospinal cavity to buffer pressure within it. It may be possible to differentiate normal from increased intracranial pressure by detection of the SVP in CSF in the ventricular system. (author)

  3. Simulation of a pulsatile total artificial heart: Development of a partitioned Fluid Structure Interaction model

    Science.gov (United States)

    Sonntag, Simon J.; Kaufmann, Tim A. S.; Büsen, Martin R.; Laumen, Marco; Linde, Torsten; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2013-04-01

    Heart disease is one of the leading causes of death in the world. Due to a shortage in donor organs artificial hearts can be a bridge to transplantation or even serve as a destination therapy for patients with terminal heart insufficiency. A pusher plate driven pulsatile membrane pump, the Total Artificial Heart (TAH) ReinHeart, is currently under development at the Institute of Applied Medical Engineering of RWTH Aachen University.This paper presents the methodology of a fully coupled three-dimensional time-dependent Fluid Structure Interaction (FSI) simulation of the TAH using a commercial partitioned block-Gauss-Seidel coupling package. Partitioned coupling of the incompressible fluid with the slender flexible membrane as well as a high fluid/structure density ratio of about unity led inherently to a deterioration of the stability (‘artificial added mass instability’). The objective was to conduct a stable simulation with high accuracy of the pumping process. In order to achieve stability, a combined resistance and pressure outlet boundary condition as well as the interface artificial compressibility method was applied. An analysis of the contact algorithm and turbulence condition is presented. Independence tests are performed for the structural and the fluid mesh, the time step size and the number of pulse cycles. Because of the large deformation of the fluid domain, a variable mesh stiffness depending on certain mesh properties was specified for the fluid elements. Adaptive remeshing was avoided. Different approaches for the mesh stiffness function are compared with respect to convergence, preservation of mesh topology and mesh quality. The resulting mesh aspect ratios, mesh expansion factors and mesh orthogonalities are evaluated in detail. The membrane motion and flow distribution of the coupled simulations are compared with a top-view recording and stereo Particle Image Velocimetry (PIV) measurements, respectively, of the actual pump.

  4. Sigmoid sinus diverticulum and pulsatile tinnitus - Analysis of CT scans from 15 cases

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhaohui; Wang, Zhenchang; Xian, Junfang; Wang, Yongzhe; Liang, Xihong [Dept. of Radiology, Capital Medical Univ., Beijing Tongren Hospital, Beijing (China); Chen, Chengfang; Gong, Shusheng; Ma, Xiaobo; Li, Yi [Dept. of Otolaryngology Head and Neck Surgery, Capital Medical Univ., Beijing Tongren Hospital, Beijing (China)], e-mail: gongs@ccmu.edu.cn

    2013-09-15

    Background: Although the imaging features of sigmoid sinus diverticulum induced pulsatile tinnitus (PT) have been presented in some extent, detailed imaging findings still have not been systematically evaluated and precise diagnostic radiographic criteria has not been established. Purpose: To examine the computed tomography (CT) characteristics of sigmoid sinus diverticulum accompanied with PT. Material and Methods: Fifteen PT patients with sigmoid sinus diverticula proven by surgery were recruited after consenting. CT images of 15 patients were obtained and analyzed, including features of diverticula, brain venous systems, integrity of the sigmoid plate, and the degree of temporal bone pneumatization. Results: Sigmoid sinus diverticulum was located on the same side of PT in 15 patients. Diverticula originated at the superior curve of the sigmoid sinus in 11 patients and the descending segment of the sigmoid sinus in four patients. Sigmoid sinus diverticula focally eroded into the adjacent mastoid air cells in 12 patients and mastoid cortex in three patients. Among eight patients with unilateral dominant brain venous systems, the diverticula were seen on the dominant side in seven patients and non-dominant side in one patient. In contrast, the other seven patients showed co-dominant brain venous systems, with three presenting diverticula on the right side and four on the left. More notably, dehiscent sigmoid plate on the PT side was demonstrated in all patients. In addition, temporal bone hyper-pneumatization was found in nine patients, good and moderate pneumatization in three patients, respectively. Conclusion: Dehiscent sigmoid plate and extensive temporal bone pneumatization are two important imaging characteristics of the PT induced by sigmoid sinus diverticulum.

  5. Sigmoid sinus diverticulum and pulsatile tinnitus - Analysis of CT scans from 15 cases

    International Nuclear Information System (INIS)

    Liu, Zhaohui; Wang, Zhenchang; Xian, Junfang; Wang, Yongzhe; Liang, Xihong; Chen, Chengfang; Gong, Shusheng; Ma, Xiaobo; Li, Yi

    2013-01-01

    Background: Although the imaging features of sigmoid sinus diverticulum induced pulsatile tinnitus (PT) have been presented in some extent, detailed imaging findings still have not been systematically evaluated and precise diagnostic radiographic criteria has not been established. Purpose: To examine the computed tomography (CT) characteristics of sigmoid sinus diverticulum accompanied with PT. Material and Methods: Fifteen PT patients with sigmoid sinus diverticula proven by surgery were recruited after consenting. CT images of 15 patients were obtained and analyzed, including features of diverticula, brain venous systems, integrity of the sigmoid plate, and the degree of temporal bone pneumatization. Results: Sigmoid sinus diverticulum was located on the same side of PT in 15 patients. Diverticula originated at the superior curve of the sigmoid sinus in 11 patients and the descending segment of the sigmoid sinus in four patients. Sigmoid sinus diverticula focally eroded into the adjacent mastoid air cells in 12 patients and mastoid cortex in three patients. Among eight patients with unilateral dominant brain venous systems, the diverticula were seen on the dominant side in seven patients and non-dominant side in one patient. In contrast, the other seven patients showed co-dominant brain venous systems, with three presenting diverticula on the right side and four on the left. More notably, dehiscent sigmoid plate on the PT side was demonstrated in all patients. In addition, temporal bone hyper-pneumatization was found in nine patients, good and moderate pneumatization in three patients, respectively. Conclusion: Dehiscent sigmoid plate and extensive temporal bone pneumatization are two important imaging characteristics of the PT induced by sigmoid sinus diverticulum

  6. Pulsatile plasma filtration and cell-free DNA amplification using a water-head-driven point-of-care testing chip.

    Science.gov (United States)

    Lee, Yonghun; Kim, Dong-Min; Li, Zhenglin; Kim, Dong-Eun; Kim, Sung-Jin

    2018-03-13

    We demonstrate a microfiltration chip that separates blood plasma by using water-head-driven pulsatile pressures rather than any external equipment and use it for on-chip amplification of nucleic acids. The chip generates pulsatile pressures to significantly reduce filter clogging without hemolysis, and consists of an oscillator, a plasma-extraction pump, and filter units. The oscillator autonomously converts constant water-head pressure to pulsatile pressure, and the pump uses the pulsatile pressure to extract plasma through the filter. Because the pulsatile pressure can periodically clear blood cells from the filter surface, filter clogging can be effectively reduced. In this way, we achieve plasma extraction with 100% purity and 90% plasma recovery at 15% hematocrit. During a 10 min period, the volume of plasma extracted was 43 μL out of a 243 μL extraction volume at 15% hematocrit. We also studied the influence of the pore size and diameter of the filter, blood loading volume, oscillation period, and hematocrit level on the filtration performance. To demonstrate the utility of our chip for point-of-care testing (POCT) applications, we successfully implemented on-chip amplification of a nucleic acid (miDNA21) in plasma filtered from blood. We expect our chip to be useful not only for POCT applications but also for other bench-top analysis tools using blood plasma.

  7. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device

    Science.gov (United States)

    Gohean, Jeffrey R.; George, Mitchell J.; Pate, Thomas D.; Kurusz, Mark; Longoria, Raul G.; Smalling, Richard W.

    2012-01-01

    The purpose of this investigation is to utilize a computational model to compare a synchronized valveless pulsatile left ventricular assist device to continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous, pulsatile, valveless, dual piston positive displacement pump. These results were compared to measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared to the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device. PMID:23438771

  8. Observation of the CSF pulsatile flow in the aqueduct using cine MRI with presaturation bolus tracking, 3

    International Nuclear Information System (INIS)

    Nakajima, Satoshi

    1992-01-01

    The to-and-fro motion patterns of the CSF flow in the aqueduct in ten normal adults, ten patients with secondary normal-pressure hydrocephalus (NPH), and fourteen patients with idiopathic ventriculomegaly were analyzed using cine MRI with presaturation bolus tracking. The to-and-fro motion patterns of the CSF flow in the aqueduct were thus classified into four types according to their maximum velocity and the relative time duration of their flow in the rostral and caudal directions. The correlation between the clinical symptoms, the CT findings, the RI-cisternography findings, the results of the ICP monitorings, and the CSF pulsatile-flow patterns were then analyzed. In secondary NPH disclosing frequent B waves on ICP monitoring, the maximum velocity of the CSF flow in the aqueduct was over 15 mm/sec, and the duration of the CSF flow was longer in the caudal direction than in the rostral direction. Furthermore, the faster the maximum velocity of the CSF flow, the larger the ventricular size on CT and the more severe the CSF malabsorption on cisternography. In idiopathic ventriculomegaly, only two cases demonstrated the same CSF flow pattern as was shown in secondary NPH; the other cases demonstrated other CSF flow patterns, which were considered to indicate hydrocephalus ex vacuo or arrested hydrocephalus. The CSF pulsatile-flow pattern was assumed to change according to the degree of the CSF circulatory disorder, its compensatory process, and the plasticity of the brain. The investigation of the CSF pulsatile flow gives important information for the evaluation of various hydrocephalic conditions. (author)

  9. Dominance of the forward compression wave in determining pulsatile components of blood pressure: similarities between inotropic stimulation and essential hypertension.

    Science.gov (United States)

    Fok, Henry; Guilcher, Antoine; Brett, Sally; Jiang, Benyu; Li, Ye; Epstein, Sally; Alastruey, Jordi; Clapp, Brian; Chowienczyk, Phil

    2014-11-01

    Pulsatile components of blood pressure may arise from forward (ventricular generated) or backward wave travel in the arterial tree. The objective of this study was to determine the relative contributions of forward and backward waves to pulsatility. We used wave intensity and wave separation analysis to determine pulsatile components of blood pressure during inotropic and vasopressor stimulation by dobutamine and norepinephrine in normotensive subjects and compared pulse pressure components in hypertensive (mean±SD, 48.8±11.3 years; 165±26.6/99±14.2 mm Hg) and normotensive subjects (52.2±12.6 years; 120±14.2/71±8.2 mm Hg). Dobutamine (7.5 μg/kg per minute) increased the forward compression wave generated by the ventricle and increased pulse pressure from 36.8±3.7 to 59.0±3.4 mm Hg (mean±SE) but had no significant effect on mean arterial pressure or the midsystolic backward compression wave. By contrast, norepinephrine (50 ng/kg per minute) had no significant effect on the forward compression wave but increased the midsystolic backward compression wave. Despite this increase in the backward compression wave, and an increase in mean arterial pressure, norepinephrine increased central pulse pressure less than dobutamine (increases of 22.1±3.8 and 7.2±2.8 mm Hg for dobutamine and norepinephrine, respectively; Phypertensive and normotensive subjects, respectively; Phypertensive and normotensive subjects. Increased central pulse pressure during inotropic stimulation and in essential hypertension results primarily from the forward compression wave. © 2014 American Heart Association, Inc.

  10. Pulsatile Hyperglycaemia Induces Vascular Oxidative Stress and GLUT 1 Expression More Potently than Sustained Hyperglycaemia in Rats on High Fat Diet

    DEFF Research Database (Denmark)

    Rakipovski, Gunaj; Lykkesfeldt, Jens; Raun, Kirsten

    2016-01-01

    expression of glucose transporter 1 (GLUT1), gp-91(PHOX) and super oxide dismutase (SOD), while only the PLG group showed increased accumulation of oxidative stress and oxidised low density lipoprotein (oxLDL) in aorta. Conclusion Pulsatile hyperglycaemia induced relatively higher levels of oxidative stress......Introduction Pulsatile hyperglycaemia resulting in oxidative stress may play an important role in the development of macrovascular complications. We investigated the effects of sustained vs. pulsatile hyperglycaemia in insulin resistant rats on markers of oxidative stress, enzyme expression...... and glucose metabolism in liver and aorta. We hypothesized that liver's ability to regulate the glucose homeostasis under varying states of hyperglycaemia may indirectly affect oxidative stress status in aorta despite the amount of glucose challenged with. Methods Animals were infused with sustained high (SHG...

  11. Real time monitoring of pulsatile change in hemoglobin concentrations of cerebral tissue by a portable tissue oximeter with a 10-Hz sampling rate

    Science.gov (United States)

    Shiga, Toshikazu; Chihara, Eiichi; Tanabe, Kazuhisa; Tanaka, Yoshifumi; Yamamoto, Katsuyuki

    1998-01-01

    A portable CW tissue oximeter of a 10-Hz sampling rate was developed for examination of pulsatile components of the output signals as a mean of checking the signal reliability during long-term monitoring. Feasible studies were performed on a healthy subject. Changes in Hb and HbO2 signals of cerebral tissue were continuously measured by placing a photoprobe on the forehead during 6-hour sleep. Pulsatile changes in Hb and HbO2 were steadily observed over a whole period of the recording. The phase relation of pulsation in Hb and HbO2 was almost inverse. Not only information for reliable monitoring but also physiological parameters with respect to cerebral circulation and metabolism could be obtained by measuring the pulsatile components.

  12. AA Index

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The geomagnetic aa index provides a long climatology of global geomagnetic activity using 2 antipodal observatories at Greenwich and Melbourne- IAGA Bulletin 37,...

  13. Diversity Index

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — This map service summarizes racial and ethnic diversity in the United States in 2012.The Diversity Index shows the likelihood that two persons chosen at random from...

  14. Walkability Index

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Walkability Index dataset characterizes every Census 2010 block group in the U.S. based on its relative walkability. Walkability depends upon characteristics of...

  15. Intelligent indexing

    International Nuclear Information System (INIS)

    Farkas, J.

    1992-01-01

    In this paper we discuss the relevance of artificial intelligence to the automatic indexing of natural language text. We describe the use of domain-specific semantically-based thesauruses and address the problem of creating adequate knowledge bases for intelligent indexing systems. We also discuss the relevance of the Hilbert space ι 2 to the compact representation of documents and to the definition of the similarity of natural language texts. (author). 17 refs., 2 figs

  16. Neuroimaging abnormalities in Griscelli's disease

    International Nuclear Information System (INIS)

    Sarper, Nazan; Akansel, Guer; Aydogan, Metin; Gedikbasi, Demet; Babaoglu, Kadir; Goekalp, Ayse Sevim

    2002-01-01

    Griscelli's disease is a rare autosomal recessive immunodeficiency syndrome. We report a 7-1/2-month-old white girl who presented with this syndrome, but initially without neurological abnormalities. Initial CT of the brain was normal. Despite haematological remission with chemotherapy, she developed neurological symptoms, progressing to coma. At this time, CT showed areas of coarse calcification in the globi pallidi, left parietal white matter and left brachium pontis. Hypodense areas were present in the genu and posterior limb of the internal capsule on the right side, as well as posterior aspects of both thalami, together with minimal generalised atrophy. MRI revealed areas of increased T2 signal and a focal area of abnormal enhancement in the subcortical white matter. Griscelli's disease should be added to the list of acquired neuroimaging abnormalities in infants. (orig.)

  17. Impaired Central Pulsatile Hemodynamics in Children and Adolescents With Marfan Syndrome.

    Science.gov (United States)

    Grillo, Andrea; Salvi, Paolo; Marelli, Susan; Gao, Lan; Salvi, Lucia; Faini, Andrea; Trifirò, Giuliana; Carretta, Renzo; Pini, Alessandro; Parati, Gianfranco

    2017-11-07

    Marfan syndrome is characterized by aortic root dilation, beginning in childhood. Data about aortic pulsatile hemodynamics and stiffness in pediatric age are currently lacking. In 51 young patients with Marfan syndrome (12.0±3.3 years), carotid tonometry was performed for the measurement of central pulse pressure, pulse pressure amplification, and aortic stiffness (carotid-femoral pulse wave velocity). Patients underwent an echocardiogram at baseline and at 1 year follow-up and a genetic evaluation. Pathogenetic fibrillin-1 mutations were classified between "dominant negative" and "haploinsufficient." The hemodynamic parameters of patients were compared with those of 80 sex, age, blood pressure, and heart-rate matched controls. Central pulse pressure was significantly higher (38.3±12.3 versus 33.6±7.8 mm Hg; P =0.009), and pulse pressure amplification was significantly reduced in Marfan than controls (17.9±15.3% versus 32.3±17.4%; P Marfan and controls (4.98±1.00 versus 4.75±0.67 m/s). In the Marfan group, central pulse pressure and pulse pressure amplification were independently associated with aortic diameter at the sinuses of Valsalva (respectively, β=0.371, P =0.010; β=-0.271, P =0.026). No significant difference in hemodynamic parameters was found according to fibrillin-1 genotype. Patients who increased aortic Z-scores at 1-year follow-up presented a higher central pulse pressure than the remaining (42.7±14.2 versus 32.3±5.9 mm Hg; P =0.004). Central pulse pressure and pulse pressure amplification were impaired in pediatric Marfan syndrome, and associated with aortic root diameters, whereas aortic pulse wave velocity was similar to that of a general pediatric population. An increased central pulse pressure was present among patients whose aortic dilatation worsened at 1-year follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  18. Low-Dose Pulsatile Interleukin-6 As a Treatment Option for Diabetic Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    Gautam Ghatnekar

    2017-05-01

    Full Text Available Diabetic peripheral neuropathy (DPN remains one of the most common and serious complications of diabetes. Currently, pharmacological agents are limited to treating the pain associated with DPN, and do not address the underlying pathological mechanisms driving nerve damage, thus leaving a significant unmet medical need. Interestingly, research conducted using exercise as a treatment for DPN has revealed interleukin-6 (IL-6 signaling to be associated with many positive benefits such as enhanced blood flow and lipid metabolism, decreased chronic inflammation, and peripheral nerve fiber regeneration. IL-6, once known solely as a pro-inflammatory cytokine, is now understood to signal as a multifunctional cytokine, capable of eliciting both pro- and anti-inflammatory responses in a context-dependent fashion. IL-6 released from muscle in response to exercise signals as a myokine and as such has a unique kinetic profile, whereby levels are transiently elevated up to 100-fold and return to baseline levels within 4 h. Importantly, this kinetic profile is in stark contrast to long-term IL-6 elevation that is associated with pro-inflammatory states. Given exercise induces IL-6 myokine signaling, and exercise has been shown to elicit numerous beneficial effects for the treatment of DPN, a causal link has been suggested. Here, we discuss both the clinical and preclinical literature related to the application of IL-6 as a treatment strategy for DPN. In addition, we discuss how IL-6 may directly modulate Schwann and nerve cells to explore a mechanistic understanding of how this treatment elicits a neuroprotective and/or regenerative response. Collectively, studies suggest that IL-6, when administered in a low-dose pulsatile strategy to mimic the body’s natural response to exercise, may prove to be an effective treatment for the protection and/or restoration of peripheral nerve function in DPN. This review highlights the studies supporting this assertion and

  19. The effect of fluid viscosity on the hemodynamic energy changes during operation of the pulsatile ventricular assist device.

    Science.gov (United States)

    Ahn, Chi Bum; Son, Kuk Hui; Lee, Jung Joo; Choi, Jaesoon; Song, Seung Joon; Jung, Jae Seung; Lee, Sung Ho; Son, Ho Sung; Sun, Kyung

    2011-11-01

    Blood viscosity during operation of ventricular assist device (VAD) can be changed by various conditions such as anemia. It is known generally that the blood viscosity can affect vascular resistance and lead to change of blood flow. In this study, the effect of fluid viscosity variation on hemodynamic energy was evaluated with a pulsatile blood pump in a mock system. Six solutions were used for experiments, which were composed of water and glycerin and had different viscosities of 2, 2.5, 3, 3.5, 4, and 4.5 cP. The hemodynamic energy at the outlet cannula was measured. Experimental results showed that mean pressure was increased in accordance with the viscosity increase. When the viscosity increased, the mean pressure was also increased. However, the flow was decreased according to the viscosity increase. Energy equivalent pressure value was increased according to the viscosity-induced pressure rise; however, surplus hemodynamic energy value did not show any apparent changing trend. The hemodynamic energy made by the pulsatile VAD was affected by the viscosity of the circulating fluid. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Changes in Bone Mineral Density and Metabolic Parameters after Pulsatile Gonadorelin Treatment in Young Men with Hypogonadotropic Hypogonadism

    Directory of Open Access Journals (Sweden)

    Chen-Xi Li

    2015-01-01

    Full Text Available To assess the prevalence of osteoporosis in young men with hypogonadotropic hypogonadism (HH and to investigate the changes of BMD and metabolic parameters, a total of 22 young male patients with HH and 20 healthy controls were enrolled in the study. BMD, biochemical, and hormonal parameters were measured in two groups. Osteoporosis was more prevalent in HH patients (45.45% than the control subjects (10.00% (P<0.001. The patients with HH had lower BMD in lumbar spine 2–4, femoral neck, and total hip (P<0.001, for all and higher fasting insulin (P=0.001, HOMA-IR (P=0.002, and SHBG (P<0.001 compared to the controls. After 6 months of pulsatile gonadorelin treatment, BMI (P=0.021 and BMD in lumbar spine 2–4, femoral neck, and total hip (P=0.002, P=0.003, and P=0.003, resp. increased dramatically and total cholesterol (P=0.034, fasting insulin (P=0.025, HOMA-IR (P=0.021, and SHBG (P=0.001 decreased significantly in HH patients. The study shows a higher prevalence of osteoporosis in young men with HH. Long-term pulsatile gonadorelin treatment indicates a positive effect on BMD and metabolic parameters of HH patients.

  1. Experimental and theoretical investigations of Lantana camara oil diffusion from polyacrylonitrile membrane for pulsatile drug delivery system

    International Nuclear Information System (INIS)

    Verma, Vivek; Balasubramanian, K.

    2014-01-01

    Porous composite membrane of polyacrylonitrile (PAN) and Lantana camara essential oil was synthesized by solvent casting method. Stability of oil in PAN solution was measured by XiGo nano tool indicating constant relaxation time of 1487 time/s. Pore size of few microns confirmed by electron microscopy was supported by atomic force microscopy indicating roughness factor of 0.9 nm. Contact angle of 2° inveterates superhydrophilicity of the composite membrane. Membrane showed excellent antibacterial activity against both Gram-positive Bacillus subtilis and Gram-negative Escherichia coli with a 7–10 mm zone of inhibition. In vitro release of Lantana oil from the composite membrane was carried out in isotonic phosphate buffer solution (pH = 7.4). Lantana oil was released for 9 h, lag time of 3 h with constant 33% release confirmed PAN membranes as potential system for pulsatile drug delivery applications. Diffusion of E-caryophyllene (antibacterial component of oil) which was studied through molecular simulation using Material Studio software ensued diffusion coefficient value of 1.11 ∗ 10 −9 m 2 /s. Biocompatibility of the composite membrane was assessed by mouse embryonic fibroblast cell line (NIH 3T3) through MTT assay indicating more than 91% viable cell even at 200 μg/mL concentration. Such membranes can be efficiently used in biomedical applications as antibacterial and antifungal agent. - Highlights: • Pulsatile release • Lantana oil–PAN composite membrane as antibacterial material • Enhanced bactericidal activity of the membrane

  2. The correlation between pulsatile intracranial pressure and indices of intracranial pressure-volume reserve capacity: results from ventricular infusion testing.

    Science.gov (United States)

    Eide, Per Kristian

    2016-12-01

    OBJECTIVE The objective of this study was to examine how pulsatile and static intracranial pressure (ICP) scores correlate with indices of intracranial pressure-volume reserve capacity, i.e., intracranial elastance (ICE) and intracranial compliance (ICC), as determined during ventricular infusion testing. METHODS All patients undergoing ventricular infusion testing and overnight ICP monitoring during the 6-year period from 2007 to 2012 were included in the study. Clinical data were retrieved from a quality registry, and the ventricular infusion pressure data and ICP scores were retrieved from a pressure database. The ICE and ICC (= 1/ICE) were computed during the infusion phase of the infusion test. RESULTS During the period from 2007 to 2012, 82 patients with possible treatment-dependent hydrocephalus underwent ventricular infusion testing within the department of neurosurgery. The infusion tests revealed a highly significant positive correlation between ICE and the pulsatile ICP scores mean wave amplitude (MWA) and rise-time coefficient (RTC), and the static ICP score mean ICP. The ICE was negatively associated with linear measures of ventricular size. The overnight ICP recordings revealed significantly increased MWA (> 4 mm Hg) and RTC (> 20 mm Hg/sec) values in patients with impaired ICC ( 4 mm Hg, RTC > 20 mm Hg/sec), but not increased mean ICP (pressure-volume reserve capacity, i.e., ICE and ICC.

  3. Design and Testing of a Pulsatile Conditioning System for Dynamic Endothelialization of Polyphenol-Stabilized Tissue Engineered Heart Valves.

    Science.gov (United States)

    Sierad, Leslie Neil; Simionescu, Agneta; Albers, Christopher; Chen, Joseph; Maivelett, Jordan; Tedder, Mary Elizabeth; Liao, Jun; Simionescu, Dan T

    2010-06-01

    Heart valve tissue engineering requires biocompatible and hemocompatible scaffolds that undergo remodeling and repopulation, but that also withstand harsh mechanical forces immediately following implantation. We hypothesized that reversibly stabilized acellular porcine valves, seeded with endothelial cells and conditioned in pulsatile bioreactors would pave the way for next generations of tissue engineered heart valves (TEHVs). A novel valve conditioning system was first designed, manufactured and tested to adequately assess TEHVs. The bioreactor created proper closing and opening of valves and allowed for multiple mounting methods in sterile conditions. Porcine aortic heart valve roots were decellularized by chemical extractions and treated with penta-galloyl glucose (PGG) for stabilization. Properties of the novel scaffolds were evaluated by testing resistance to collagenase and elastase, biaxial mechanical analysis, and thermal denaturation profiles. Porcine aortic endothelial cells were seeded onto the leaflets and whole aortic roots were mounted within the dynamic pulsatile heart valve bioreactor system under physiologic pulmonary valve pressures and analyzed after 17 days for cell viability, morphology, and metabolic activity. Our tissue preparation methods effectively removed cells, including the potent α-Gal antigen, while leaving a well preserved extra-cellular matrix scaffold with adequate mechanical properties. PGG enhanced stabilization of extracellular matrix components but also showed the ability to be reversible. Engineered valve scaffolds encouraged attachment and survival of endothelial cells for extended periods and showed signs of widespread cell coverage after conditioning. Our novel approach shows promise toward development of sturdy and durable TEHVs capable of remodeling and cellular repopulation.

  4. Anti-Mullerian hormone levels do not predict response to pulsatile GnRH in women with hypothalamic amenorrhea.

    Science.gov (United States)

    Billington, Emma O; Corenblum, Bernard

    2016-09-01

    Pulsatile GnRH is used to induce ovulation in women with hypothalamic amenorrhea (HA), but tools to predict response are lacking. We assessed whether baseline AMH levels are associated with response to pulsatile GnRH in 16 women with HA. AMH levels were compared between non-responders and women who achieved follicular development or pregnancy. Median AMH for the cohort was 2.2 ng/mL. AMH levels were undetectable or low in four women, normal in nine and high in three. Follicular development was observed in 13 (81%) women (82% of cycles) and pregnancy achieved in 10 (63%) women (29% of cycles). All four women with low or undetectable AMH had follicular response and three achieved pregnancy. Of the 12 women with normal or high AMH, 10 had a follicular response and seven achieved pregnancy. Median AMH levels were comparable in those who achieved follicular development and those who did not (2.2 ng/mL versus 1.3 ng/mL, p = 0.78) and in those who became pregnant and those who did not (2.2 ng/mL versus 1.9 ng/mL, p = 0.52). In summary, low AMH does not preclude response to ovulation induction in women with HA, suggesting that ovarian potential may not be the primary determinant of AMH concentrations in this population.

  5. Triorchidism: A Rare Genitourinary Abnormality

    African Journals Online (AJOL)

    During early adulthood it will be carried out by palpation, ultrasonography, semen analysis, serum testosterone and follicle stimulating hormone levels and during late adulthood follow up will be done by ultrasonography for malignancy every 2 years. CONCLUSION. Polyorchidism is a rare genitourinary abnormality and its.

  6. Chromosomal abnormalities associated with omphalocele.

    Science.gov (United States)

    Chen, Chih-Ping

    2007-03-01

    Fetuses with omphalocele have an increased risk for chromosomal abnormalities. The risk varies with maternal age, gestational age at diagnosis, association with umbilical cord cysts, complexity of associated anomalies, and the contents of omphalocele. There is considerable evidence that genetics contributes to the etiology of omphalocele. This article provides an overview of chromosomal abnormalities associated with omphalocele and a comprehensive review of associated full aneuploidy such as trisomy 18, trisomy 13, triploidy, trisomy 21, 45,X, 47,XXY, and 47,XXX, partial aneuploidy such as dup (3q), dup (11p), inv (11), dup (1q), del (1q), dup (4q), dup (5p), dup (6q), del (9p), dup (15q), dup(17q), Pallister-Killian syndrome with mosaic tetrasomy 12p and Miller-Dieker lissencephaly syndrome with deletion of 17p13.3, and uniparental disomy (UPD) such as UPD 11 and UPD 14. Omphalocele is a prominent marker for chromosomal abnormalities. Perinatal identification of omphalocele should alert chromosomal abnormalities and familial unbalanced translocations, and prompt thorough cytogenetic investigations and genetic counseling.

  7. Chromosomal Abnormalities Associated With Omphalocele

    Directory of Open Access Journals (Sweden)

    Chih-Ping Chen

    2007-03-01

    Full Text Available Fetuses with omphalocele have an increased risk for chromosomal abnormalities. The risk varies with maternal age, gestational age at diagnosis, association with umbilical cord cysts, complexity of associated anomalies, and the contents of omphalocele. There is considerable evidence that genetics contributes to the etiology of omphalocele. This article provides an overview of chromosomal abnormalities associated with omphalocele and a comprehensive review of associated full aneuploidy such as trisomy 18, trisomy 13, triploidy, trisomy 21, 45,X, 47,XXY, and 47,XXX, partial aneuploidy such as dup(3q, dup(11p, inv(11, dup(1q, del(1q, dup(4q, dup(5p, dup(6q, del(9p, dup(15q, dup(17q, Pallister-Killian syndrome with mosaic tetrasomy 12p and Miller-Dieker lissencephaly syndrome with deletion of 17p13.3, and uniparental disomy (UPD such as UPD 11 and UPD 14. Omphalocele is a prominent marker for chromosomal abnormalities. Perinatal identification of omphalocele should alert chromosomal abnormalities and familial unbalanced translocations, and prompt thorough cytogenetic investigations and genetic counseling.

  8. Admission haematological abnormalities and postoperative ...

    African Journals Online (AJOL)

    Admission haematological abnormalities and postoperative outcomes in neonates with acute surgical conditions in Alexandria, Egypt. HL Wella, SMM Farahat. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals ...

  9. ANALYSIS OF ABNORMALITIES IN COMMON CAROTID ARTERY IMAGES USING MULTIWAVELETS

    Directory of Open Access Journals (Sweden)

    R Nandakumar

    2016-11-01

    Full Text Available According to the report given by World Health Organization, by 2030 almost 23.6 million people will die from cardiovascular diseases (CVD, mostly from heart disease and stroke. The main objective of this work is to develop a classifier for the diagnosis of abnormal Common Carotid Arteries (CCA. This paper proposes a new approach for the analysis of abnormalities in longitudinal B-mode ultrasound CCA images using multiwavelets. Analysis is done using HM and GHM multiwavelets at various levels of decomposition. Energy values of the coefficients of approximation, horizontal, vertical and diagonal details are calculated and plotted for different levels. Plots of energy values show high correlation with the abnormalities of CCA and offer the possibility of improved diagnosis of CVD. It is clear that the energy values can be used as an index of individual atherosclerosis and to develop a cost effective system for cardiovascular risk assessment at an early stage.

  10. Indexing mechanisms

    International Nuclear Information System (INIS)

    Wood, A.G.; Parker, G.E.; Berry, R.

    1976-01-01

    It is stated that the indexing mechanism described can be used in a nuclear reactor fuel element inspection rig. It comprises a tubular body adapted to house a canister containing a number of fuel elements located longtitudinally, and has two chucks spaced apart for displacing the fuel elements longitudinally in a stepwise manner, together with a plunger mechanism for displacing them successively into the chucks. A measuring unit is located between the chucks for measuring the diameter of the fuel elements at intervals about their circumferences, and a secondary indexing mechanism is provided for rotating the measuring unit in a stepwise manner. (U.K.)

  11. Author Index

    Indian Academy of Sciences (India)

    Author Index. Alshaary, A. A. see Sharaf, M. A., 9. Banajh, M. A. see Sharaf, M. A., 9. Burbidge Geoffrey see Narlikar Jayant, V., 67. Chen, H. D. see Li, K. J., 147. Chen, Y. Q. see Huang, C., 139. Cui Wenyuan Evolution of the Distribution of Neutron Exposures in the Galaxy. Disc: An Analytical Model, 55. Dhurde Samir see ...

  12. Author Index

    Indian Academy of Sciences (India)

    Author Index. Alecian, E. see Samadhi, R., 171; see Goupil, M.-J., 249. Antia, H. M. Helioseismology, 161. Ashoka, B. N. see Seetha, S., 301. Baudin, F. see Samadhi, R., 171. Boehm, T. see Goupil, M.-J., 249. Catala, C. see Goupil, M.-J., 249. Cunha Margarida S. Asteroseismic Theory of Rapidly Oscillating Ap Stars, 213.

  13. SUBJECT INDEX

    Indian Academy of Sciences (India)

    Unknown

    SUBJECT INDEX. Absorption. Effect of NaCl on the spectral and kinetic properties of cresyl violet (CV)-sodium dodecyl sulphate (SDS) complex. 299. Acid catalysts. Temperature-programmed desorption of water and ammonia on sulphated zirconia catalysts for measuring their strong acidity and acidity distribution. 281.

  14. Author Index

    Indian Academy of Sciences (India)

    J. Astrophys. Astr. (2008) 29, 405–409. Author Index. Aggarwal Malini see Jain Rajmal, 125; X-ray Emission Characteristics of Flares. Associated with CMEs, 195. Alyana Radharani see Rathod Jatin, 293; see Reddy Chandrasekhar, A., 313. Ambastha Ashok Helioseismic Effects of Energetic Transients, 93; see Maurya.

  15. SUBJECT INDEX

    Indian Academy of Sciences (India)

    Unknown

    SUBJECT INDEX. Ab initio calculations. Basis set effects on energy and hardness profiles of the hydrogen fluoride dimer. 549. Activation by calcinations. Highly active and reusable catalyst from Fe-Mg- hydrotalcite anionic clay for Friedel–Crafts type benzyla- tion reactions. 635. Adsorption. Adsorption studies of iron(III) on ...

  16. Author Index

    Indian Academy of Sciences (India)

    Author Index. Aggarwal Malini see Jain Rajmal, 155. Aghaee, A. Determination of the Mean Hi Absorption of the Intergalactic. Medium, 59. Agrawal, S. P. see Singh Ambika, 89. Biesiada Marek Could the Optical Transient SCP 06F6 be due to Micro- lensing?, 213. C¸ aliskan, S . see Küçük, ˙I., 135. Evans Lloyd, T. Carbon ...

  17. Author Index

    Indian Academy of Sciences (India)

    Author Index. Ahmad Farooq see Iqbal Naseer, 373. Ali Syed Salman Study of a Large Helical Eruptive Prominence Associated with. Double CME on 21 April 2001, 347; see Uddin Wahab, 267. Ali, A. Chemistry of Carbon Rich Star IRAS 15194–5115, 399. Ambastha Ashok Photospheric, Chromospheric and Helioseismic ...

  18. Subject Index

    Indian Academy of Sciences (India)

    J. Astrophys. Astr. (2006) 27, 469–472. Subject Index. Astrophysical Processes. Spatial Damping of Linear Compressional Magnetoacoustic Waves in Quiescent. Prominences (K. A. P. Singh), 321. Report on the Dynamical Evolution of an Axially Symmetric Quasar Model. (N. J. Papadopoulos & N. D. Caranicolas), 389.

  19. SUBJECT INDEX

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    SUBJECT INDEX. 1D inversion. A direct inversion scheme for deep resistivity sound- ing data using artificial neural networks. 49. 40. Ar-. 39. Ar thermochronology. Tectono-thermal evolution of the India-Asia colli- sion zone based on. 40. Ar-. 39. Ar thermochronology in. Ladakh, India. 737. ANN. Artificial neural network ...

  20. Index Fossils

    Indian Academy of Sciences (India)

    stricted geologic time range, easily preservable, of short species duration and found in multiple environment. Index fossils are used by geologists and palaeontologists as significant aids to determine the correlation and age of rock sequences [2]. Geologists use both large fossils or 'macrofossils' and microscopic fossils or ...

  1. Author Index

    Indian Academy of Sciences (India)

    user1

    Yan, X. L. see Deng, L. H., 221. Phase Relationship Between Sunspot Number, Flare Index and Solar Radio. Flux, 387. ZANINETTI, L. Revisiting the Cosmological Principle in a Cellular Framework, 399. ZHAO XIAN-FENG. Constraints on the Moment of Inertia of a Proto Neutron Star from the Hyperon Coupling Constants, ...

  2. Index Fossils

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 10. Index Fossils - Evidences from Plant Sources. Dipanjan Ghosh. General Article ... Author Affiliations. Dipanjan Ghosh1. Biological Science Department Kirnahar Shib Chandra High School Kirnahar, Birbhum 731302, West Bengal, India.

  3. Optimal Signal Quality Index for Photoplethysmogram Signals

    Directory of Open Access Journals (Sweden)

    Mohamed Elgendi

    2016-09-01

    Full Text Available A photoplethysmogram (PPG is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is typically collected by pulse oximeters. PPG signals collected via mobile devices are prone to artifacts that negatively impact measurement accuracy, which can lead to a significant number of misleading diagnoses. Given the rapidly increased use of mobile devices to collect PPG signals, developing an optimal signal quality index (SQI is essential to classify the signal quality from these devices. Eight SQIs were developed and tested based on: perfusion, kurtosis, skewness, relative power, non-stationarity, zero crossing, entropy, and the matching of systolic wave detectors. Two independent annotators annotated all PPG data (106 recordings, 60 s each and a third expert conducted the adjudication of differences. The independent annotators labeled each PPG signal with one of the following labels: excellent, acceptable or unfit for diagnosis. All indices were compared using Mahalanobis distance, linear discriminant analysis, quadratic discriminant analysis, and support vector machine with leave-one-out cross-validation. The skewness index outperformed the other seven indices in differentiating between excellent PPG and acceptable, acceptable combined with unfit, and unfit recordings, with overall F 1 scores of 86.0%, 87.2%, and 79.1%, respectively.

  4. Optimal Signal Quality Index for Photoplethysmogram Signals.

    Science.gov (United States)

    Elgendi, Mohamed

    2016-09-22

    A photoplethysmogram (PPG) is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is typically collected by pulse oximeters. PPG signals collected via mobile devices are prone to artifacts that negatively impact measurement accuracy, which can lead to a significant number of misleading diagnoses. Given the rapidly increased use of mobile devices to collect PPG signals, developing an optimal signal quality index (SQI) is essential to classify the signal quality from these devices. Eight SQIs were developed and tested based on: perfusion, kurtosis, skewness, relative power, non-stationarity, zero crossing, entropy, and the matching of systolic wave detectors. Two independent annotators annotated all PPG data (106 recordings, 60 s each) and a third expert conducted the adjudication of differences. The independent annotators labeled each PPG signal with one of the following labels: excellent, acceptable or unfit for diagnosis. All indices were compared using Mahalanobis distance, linear discriminant analysis, quadratic discriminant analysis, and support vector machine with leave-one-out cross-validation. The skewness index outperformed the other seven indices in differentiating between excellent PPG and acceptable, acceptable combined with unfit, and unfit recordings, with overall F 1 scores of 86.0%, 87.2%, and 79.1%, respectively.

  5. The ontogeny of pulsatile growth hormone secretion and its temporal relationship to the onset of puberty in the agonadal male rhesus monkey (Macaca mulatta).

    Science.gov (United States)

    Suter, K J

    2004-05-01

    The pubertal amplification of GH secretion in primates has been thought to reflect an increase in gonadal steroid hormones due to gonadotropin stimulation induced by hypothalamic GnRH release. Previous studies in agonadal, peripubertal, male rhesus monkeys have estimated the age of GnRH activation (defined as d 0) using analyses of nocturnal, pulsatile LH patterns derived from sequential blood samples. Using samples from these earlier studies, secretory patterns of GH were analyzed using Cluster at approximately 30-d intervals in the youngest prepubertal ages and at approximately 10- to 20-d intervals in the period immediately preceding and following the onset of puberty. Pulse frequency, amplitude, and mean GH increased significantly between early prepubertal ages (up to 30 d before d 0) and the late prepubertal period (between -20 d and d 0). Pulsatile GH activity increased earlier than pulsatile LH secretion in four of five animals. These findings support the conclusion that pulsatile GH secretion increases developmentally in the absence of gonadal steroids. Furthermore, the present observation that the developmental increase in GH secretion occurs earlier than previously reported is consistent with the possibility that GH itself either directly or indirectly participates in the pubertal reinitiation of GnRH pulse generator activity.

  6. Abnormal lung function at preschool age - asthma in adolescence?

    Science.gov (United States)

    Lajunen, Katariina; Kalliola, Satu; Kotaniemi-Syrjänen, Anne; Sarna, Seppo; Malmberg, L Pekka; Pelkonen, Anna S; Mäkelä, Mika J

    2018-03-06

    Asthma often begins early in childhood. However, the risk for persistence is challenging to evaluate. This longitudinal study relates lung function assessed with impulse oscillometry (IOS) in preschool children to asthma in adolescence. Lung function was measured with IOS in 255 children with asthma-like symptoms aged 4-7 years. Baseline measurements were followed by exercise challenge and bronchodilation tests. At age 12-16 years, 121 children participated in the follow-up visit, when lung function was assessed with spirometry, followed by a bronchodilation test. Asthma symptoms and medication were recorded by a questionnaire and atopy defined by skin prick tests. Abnormal baseline values in preschool IOS were significantly associated with low lung function, the need for asthma medication, and asthma symptoms in adolescence. Preschool abnormal R5 at baseline (z-score ≥1.645 SD) showed 9.2 odds ratio (95%CI 2.7;31.7) for abnormal FEV1/FVC, use of asthma medication in adolescence, and 9.9 odds ratio (95%CI 2.9;34.4) for asthma symptoms. Positive exercise challenge and modified asthma-predictive index at preschool age predicted asthma symptoms and the need for asthma medication, but not abnormal lung function at teenage. Abnormal preschool IOS is associated with asthma and poor lung function in adolescence and might be utilised for identification of asthma persistence. Copyright © 2018. Published by Elsevier Inc.

  7. Pulmonary artery pulsatility and effect on vessel diameter assessment in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shariat, Masoud, E-mail: masoudshariat@gmail.com [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Schantz, Daryl, E-mail: daryl.schantz@gmail.com [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Yoo, Shi-Joon, E-mail: shi-joon.yoo@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Wintersperger, Bernd J., E-mail: bernd.wintersperger@uhn.ca [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Seed, Mike, E-mail: mike.seed@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Department of Cardiology, Hospital for Sick Children, Toronto, Ontario (Canada); Alnafisi, Bahiyah, E-mail: bahiyah.alnafisi@uhn.ca [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Chu, Leysia, E-mail: leysia_99@yahoo.com [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); MacGowan, Christopher K., E-mail: christopher.macgowan@sickkids.ca [Department of Physiology and Experimental Medicine, Hospital for Sick Children, Toronto, Ontario (Canada); Amerom, Joshua van, E-mail: Joshu.vanamerom@sickkids.ca [Department of Physiology and Experimental Medicine, Hospital for Sick Children, Toronto, Ontario (Canada); Grosse-Wortmann, Lars, E-mail: lars.grosse-wortmann@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Department of Cardiology, Hospital for Sick Children, Toronto, Ontario (Canada)

    2014-02-15

    systolic cine SSFP or MRA in both groups (p < 0.0001). Vessel diameters measured on systolic SSFP were significantly larger than measurements made on diastolic SSFP (p < 0.0001). There was no significant difference between vessel measurements on MRA and measurements on systolic cine SSFP (p = 0.44 for the TOF group and p = 0.79 for ARVC group). Measurements on the MRA datasets were significantly larger than those on diastolic SSFP images (p < 0.0001). Conclusion: Black blood, white blood and MRA sequences are all reproducible CMR methods for the assessment of arterial diameters in children and adolescents. Measurements from systolic phase SSFP images are comparable to those from contrast-enhanced MRA. Therefore, the administration of contrast medium is not necessary in every case. Cine SSFP images offer the additional advantage over the other methods in such that both the largest and the smallest diameter of the vessel during the cardiac cycle can be assessed using this technique. This is even more relevant in highly pulsatile circulations, such as patients with repaired TOF and significant pulmonary insufficiency.

  8. Pulmonary artery pulsatility and effect on vessel diameter assessment in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shariat, Masoud; Schantz, Daryl; Yoo, Shi-Joon; Wintersperger, Bernd J.; Seed, Mike; Alnafisi, Bahiyah; Chu, Leysia; MacGowan, Christopher K.; Amerom, Joshua van; Grosse-Wortmann, Lars

    2014-01-01

    systolic cine SSFP or MRA in both groups (p < 0.0001). Vessel diameters measured on systolic SSFP were significantly larger than measurements made on diastolic SSFP (p < 0.0001). There was no significant difference between vessel measurements on MRA and measurements on systolic cine SSFP (p = 0.44 for the TOF group and p = 0.79 for ARVC group). Measurements on the MRA datasets were significantly larger than those on diastolic SSFP images (p < 0.0001). Conclusion: Black blood, white blood and MRA sequences are all reproducible CMR methods for the assessment of arterial diameters in children and adolescents. Measurements from systolic phase SSFP images are comparable to those from contrast-enhanced MRA. Therefore, the administration of contrast medium is not necessary in every case. Cine SSFP images offer the additional advantage over the other methods in such that both the largest and the smallest diameter of the vessel during the cardiac cycle can be assessed using this technique. This is even more relevant in highly pulsatile circulations, such as patients with repaired TOF and significant pulmonary insufficiency

  9. Physiologic chart for rapid identification of causes of abnormal haemodynamics.

    Science.gov (United States)

    Sramek, B B

    1994-11-01

    The systemic haemodynamic state is expressed by paired values of Mean Arterial Pressure (MAP) and Stroke Index (SI), varying for every heart beat. Algebraic product of SI and Heart Rate (HR) then defines the perfusion-related Cardiac Index (CI), which is the dynamic modulator of Oxygen Delivery Index (DO2I). Since MAP, SI and CI can each attain a normal, infranormal or supranormal level, there is a total of 9 haemodynamic states, plus 3 CI states. A patient with normal haemodynamics has MAP, SI and CI within his/her normal ranges. The remaining 8 abnormal haemodynamic states and 2 abnormal CI states are the vectorial end-result of a combination of abnormal levels of haemodynamic modulating pathways, i.e., intravascular volume, inotropy, vasoactivity and chronotropy. The Haemodynamic Management Chart (HMC) identifies the inter-relationship between the deviations in volume, inotropy and vasoactivity responsible for the observed haemodynamic state in respect to the desired haemodynamic state (Haemodynamic Therapeutic Goal [HTG]). The deviation in CI from its normal level then determines the deviation in chronotropy. In contrast to current management methodology of trial and error, the HMC enables the clinician to continuously manage a patient's haemodynamics within the HTG. This is expected to produce a shorter therapy and improved outcome.

  10. Echocardiographic abnormalities in hypertensive patients

    International Nuclear Information System (INIS)

    Rodulfo Garcia, Maikel; Tornes Perez, Victor Manuel; Castellanos Tardo, Juan Ramon

    2012-01-01

    A descriptive cross-sectional study was carried out in 120 hypertensive patients with a course of 5 or more years, who went to the emergency room of 'Saturnino Lora' Provincial Teaching Hospital from November 2010 to November 2011 in order to determine the presence or absence of echocardiographic abnormalities typical of hypertension. Of these, 78,3 % was affected, most of whom reported not to continue with regular previous medical treatment, and 21,7 % had not these abnormalities. Age group of 50-60 years, males and blacks prevailed in the case material. The most significant echocardiographic findings were left ventricular hypertrophy and heart failure with ejection fraction of left ventricle preserved

  11. Glial abnormalities in mood disorders.

    Science.gov (United States)

    Öngür, Dost; Bechtholt, Anita J; Carlezon, William A; Cohen, Bruce M

    2014-01-01

    Multiple lines of evidence indicate that mood disorders are associated with abnormalities in the brain's cellular composition, especially in glial cells. Considered inert support cells in the past, glial cells are now known to be important for brain function. Treatments for mood disorders enhance glial cell proliferation, and experimental stimulation of cell growth has antidepressant effects in animal models of mood disorders. These findings suggest that the proliferation and survival of glial cells may be important in the pathogenesis of mood disorders and may be possible targets for the development of new treatments. In this article we review the evidence for glial abnormalities in mood disorders, and we discuss glial cell biology and evidence from postmortem studies of mood disorders. The goal is not to carry out a comprehensive review but to selectively discuss existing evidence in support of an argument for the role of glial cells in mood disorders.

  12. Abnormal Metabolite in Alcoholic Subjects,

    Science.gov (United States)

    1982-01-01

    0.01 0.12 81 A.A. 51 M 0 ɘ.01 0.09 Schizophrenia 85a W.G. 67 M 0 ɘ.01 0.21 Proteins & Ketones in Urine b 0 ɘ.01 0.11 86a W.H. 67 M 0 ɘ.01 0.15 b 0...AD-AS 90 TOTTS GAP MEDICAL RESEARCH LABS INC BANGOR PA F/G 6/5 ABNORMAL METABOLITE IN ALCOHOLIC SUBJECTS, U) 1982 R L BEECH, M E FELVER, M R...LAKSCHMANAN NOOBIN 70 C 0233 UNJCLASSIFIED NL I ,I/ ABNORMAL METABOLITE IN ALCOHOLIC SUBJECTS Richard L . Veech, Michael E. Felver, M.R. Lakschmanan, Stewart

  13. Computed tomography abnormalities in hanging

    International Nuclear Information System (INIS)

    Bianco, F.; Floris, R.

    1987-01-01

    The CT pattern of bilateral and symmetrical round low density areas in the globi pallidi has been observed in a young man who attempted suicide by hanging. These CT abnormalities are similar to those described in other conditions such as carbon monoxide, hydrogen sulfide, cyanide and methanol poisoning, hypoglycaemia, drowning and acute global central nervous system hypoperfusion.The findings appear to be correlated with acute cerebral hypoxia. (orig.)

  14. GLIAL ABNORMALITIES IN MOOD DISORDERS

    OpenAIRE

    Öngür, Dost; Bechtholt, Anita J.; Carlezon, William A.; Cohen, Bruce M.

    2014-01-01

    Multiple lines of evidence indicate that mood disorders are associated with abnormalities in the brain's cellular composition, especially in glial cells. Considered inert support cells in the past, glial cells are now known to be important for brain function. Treatments for mood disorders enhance glial cell proliferation, and experimental stimulation of cell growth has antidepressant effects in animal models of mood disorders. These findings suggest that the proliferation and survival of glia...

  15. Mastoid abnormalities in Down syndrome

    International Nuclear Information System (INIS)

    Glass, R.B.J.; Yousefzadeh, D.K.; Roizen, N.J.

    1989-01-01

    Hearing loss and otitis media are commonly associated with Down syndrome. Hypoplasia of the mastoids is seen in many affected children and sclerosis of mastoid bones is not uncommon in Down syndrome. Awareness and early recognition of mastoid abnormality may lead to appropriate and timely therapy, thereby preserving the child's hearing or compensating for hearing loss; factors which are important for learning and maximum development. (orig.)

  16. Mastoid abnormalities in Down syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Glass, R.B.J.; Yousefzadeh, D.K.; Roizen, N.J.

    1989-06-01

    Hearing loss and otitis media are commonly associated with Down syndrome. Hypoplasia of the mastoids is seen in many affected children and sclerosis of mastoid bones is not uncommon in Down syndrome. Awareness and early recognition of mastoid abnormality may lead to appropriate and timely therapy, thereby preserving the child's hearing or compensating for hearing loss; factors which are important for learning and maximum development.

  17. Ptolemaic indexing

    Directory of Open Access Journals (Sweden)

    Magnus Lie Hetland

    2015-07-01

    Full Text Available This paper discusses a new family of bounds for use in similarity search, related to those used in metric indexing, but based on Ptolemy's inequality, rather than the metric axioms. Ptolemy's inequality holds for the well-known Euclidean distance, but is also shown here to hold for quadratic form metrics in general, with Mahalanobis distance as an important special case. The inequality is examined empirically on both synthetic and real-world data sets and is also found to hold approximately, with a very low degree of error, for important distances such as the angular pseudometric and several Lp norms. Indexing experiments are performed on several data sets, demonstrating a highly increased filtering power when using certain forms of Ptolemaic filtering, compared to existing, triangular methods. It is also shown that combining the Ptolemaic and triangular filtering can lead to better results than using either approach on its own.

  18. Abnormal uterine bleeding in perimenopause.

    Science.gov (United States)

    Goldstein, S R; Lumsden, M A

    2017-10-01

    Abnormal uterine bleeding is one of the commonest presenting complaints encountered in a gynecologist's office or primary-care setting. The wider availability of diagnostic tools has allowed prompt diagnosis and treatment of an increasing number of menstrual disorders in an office setting. This White Paper reviews the advantages and disadvantages of transvaginal ultrasound, blind endometrial sampling and diagnostic hysteroscopy. Once a proper diagnosis has been established, appropriate therapy may be embarked upon. Fortunately, only a minority of such patients will have premalignant or malignant disease. When bleeding is sufficient to cause severe anemia or even hypovolemia, prompt intervention is called for. In most of the cases, however, the abnormal uterine bleeding will be disquieting to the patient and significantly affect her 'quality of life'. Sometimes, reassurance and expectant management will be sufficient in such patients. Overall, however, in cases of benign disease, some intervention will be required. The use of oral contraceptive pills especially those with a short hormone-free interval, the insertion of the levonorgestrel intrauterine system, the incorporation of newer medical therapies including antifibrinolytic drugs and selective progesterone receptor modulators and minimally invasive treatments have made outpatient therapy increasingly effective. For others, operative hysteroscopy and endometrial ablation are proven therapeutic tools to provide both long- and short-term relief of abnormal uterine bleeding, thus avoiding, or deferring, hysterectomy.

  19. Piecewise function parameters as responses of the design of experiment in the development of a pulsatile release chronopharmaceutical system.

    Science.gov (United States)

    Vonica-Gligor, Andreea Loredana; Tomuţă, Ioan; Leucuţa, Sorin E

    2016-06-01

    The aim of this work was to develop a pulsatile release system with metoprolol for chronotherapeutical use by coating swellable mini-tablets with Eudragit RS. To study the influence of the formulation factors (amount of coating polymer, plasticizer percentage in film coating and swelling agent percentage in mini-tablets), a Box-Behnken design of experiment (DoE) was used. To evaluate the influence of the studied factors on the sigmoid shape of the dissolution profile, piecewise function parameters were used as the responses of DoE. The results show that higher concentrations of coating polymer and higher concentrations of plasticizer polymer led to a thicker and more elastic polymeric film, which led to a delay in drug release. Using the parameters of the piecewise function as DoE responses, an optimum formulation with a sigmoid shape dissolution profile and a 2.5-h lag time followed by rapid drug release were obtained.

  20. Basic study of intrinsic elastography: Relationship between tissue stiffness and propagation velocity of deformation induced by pulsatile flow

    Science.gov (United States)

    Nagaoka, Ryo; Iwasaki, Ryosuke; Arakawa, Mototaka; Kobayashi, Kazuto; Yoshizawa, Shin; Umemura, Shin-ichiro; Saijo, Yoshifumi

    2015-07-01

    We proposed an estimation method for a tissue stiffness from deformations induced by arterial pulsation, and named this proposed method intrinsic elastography (IE). In IE, assuming that the velocity of the deformation propagation in tissues is closely related to the stiffness, the propagation velocity (PV) was estimated by spatial compound ultrasound imaging with a high temporal resolution of 1 ms. However, the relationship between tissue stiffness and PV has not been revealed yet. In this study, the PV of the deformation induced by the pulsatile pump was measured by IE in three different poly(vinyl alcohol) (PVA) phantoms of different stiffnesses. The measured PV was compared with the shear wave velocity (SWV) measured by shear wave imaging (SWI). The measured PV has trends similar to the measured SWV. These results obtained by IE in a healthy male show the possibility that the mechanical properties of living tissues could be evaluated by IE.

  1. Effect of organic and inorganic nitrates on cerebrovascular pulsatile power transmission in patients with heart failure and preserved ejection fraction.

    Science.gov (United States)

    Londono-Hoyos, Francisco; Zamani, Payman; Beraun, Melissa; Vassim, Izzah; Segers, Patrick; Chirinos, Julio A

    2018-02-28

    Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inorganic nitrates administration in this population on the power carried by pressure and flow waves traveling through the proximal aorta and penetrating the carotid artery into the brain microvasculature. We assessed aortic and carotid hemodynamics non-invasively in 2 sub-studies: 1) at baseline and after administration of 0.4mg of sublingual nitroglycerine (an organic nitrate; n=26); and 2) from a randomized controlled trial of placebo (PB) vs. inorganic nitrate administration (beetroot-juice (BR), 12.9mmol NO3; n=16). Wave and hydraulic power analysis demonstrated that NTG increased total hydraulic power (from 5.68% at baseline to 8.62%, P=0.001) and energy penetration (from 8.69% to 11.63%; P=0.01) from the aorta to the carotid, while inorganic nitrate administration did not induce significant changes in aortic and carotid wave power (Power: 5.49%PB vs. 6.25%BR, P=0.49; Energy: 8.89%PB vs. 10.65%BR, P=0.27). Organic nitrates, but not inorganic nitrates, increase the amount of hydraulic energy transmitted into the carotid artery in subjects with HFpEF. These findings may have implications for the pulsatile hemodynamic stress of the brain microvasculature in this patient population. © 2018 Institute of Physics and Engineering in Medicine.

  2. Experimental and theoretical investigations of Lantana camara oil diffusion from polyacrylonitrile membrane for pulsatile drug delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Vivek [Department of Chemistry, Indian Institute of Science Education and Research (IISER), Pune 411008 (India); Balasubramanian, K., E-mail: meetkbs@gmail.com [Department of Materials Engineering, Defence Institute of Advance Technology (DIAT), Ministry of Defence, Girinagar, Pune 411025 (India)

    2014-08-01

    Porous composite membrane of polyacrylonitrile (PAN) and Lantana camara essential oil was synthesized by solvent casting method. Stability of oil in PAN solution was measured by XiGo nano tool indicating constant relaxation time of 1487 time/s. Pore size of few microns confirmed by electron microscopy was supported by atomic force microscopy indicating roughness factor of 0.9 nm. Contact angle of 2° inveterates superhydrophilicity of the composite membrane. Membrane showed excellent antibacterial activity against both Gram-positive Bacillus subtilis and Gram-negative Escherichia coli with a 7–10 mm zone of inhibition. In vitro release of Lantana oil from the composite membrane was carried out in isotonic phosphate buffer solution (pH = 7.4). Lantana oil was released for 9 h, lag time of 3 h with constant 33% release confirmed PAN membranes as potential system for pulsatile drug delivery applications. Diffusion of E-caryophyllene (antibacterial component of oil) which was studied through molecular simulation using Material Studio software ensued diffusion coefficient value of 1.11 ∗ 10{sup −9} m{sup 2}/s. Biocompatibility of the composite membrane was assessed by mouse embryonic fibroblast cell line (NIH 3T3) through MTT assay indicating more than 91% viable cell even at 200 μg/mL concentration. Such membranes can be efficiently used in biomedical applications as antibacterial and antifungal agent. - Highlights: • Pulsatile release • Lantana oil–PAN composite membrane as antibacterial material • Enhanced bactericidal activity of the membrane.

  3. Experience With a Long-term Pulsatile Ventricular Assist Device as a Bridge to Heart Transplant in Adults.

    Science.gov (United States)

    Gómez Bueno, Manuel; Segovia Cubero, Javier; Serrano Fiz, Santiago; Ugarte Basterrechea, Juan; Hernández Pérez, Francisco José; Goirigolzarri Artaza, Josebe; Castedo Mejuto, Evaristo; Burgos Lázaro, Raúl; García Montero, Carlos; Moñivas Palomero, Vanessa; Mingo Santos, Susana; González Román, Ana Isabel; Álvarez Avelló, José Manuel; Vidal Fernández, Mercedes; Forteza Gil, Alberto; Alonso-Pulpón, Luis

    2017-09-01

    Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Abnormal thermography in Parkinson's disease.

    Science.gov (United States)

    Antonio-Rubio, I; Madrid-Navarro, C J; Salazar-López, E; Pérez-Navarro, M J; Sáez-Zea, C; Gómez-Milán, E; Mínguez-Castellanos, A; Escamilla-Sevilla, F

    2015-08-01

    An autonomic denervation and abnormal vasomotor reflex in the skin have been described in Parkinson's disease (PD) and might be evaluable using thermography with cold stress test. A cross-sectional pilot study was undertaken in 35 adults: 15 patients with PD and abnormal [(123)I]-metaiodobenzylguanidine cardiac scintigraphy and 20 healthy controls. Baseline thermography of both hands was obtained before immersing one in cold water (3 ± 1 °C) for 2 min. Continuous thermography was performed in: non-immersed hand (right or with lesser motor involvement) during immersion of the contralateral hand and for 6 min afterward; and contralateral immersed hand for 6 min post-immersion. The region of interest was the dorsal skin of the third finger, distal phalanx. PD patients showed a lower mean baseline hand temperature (p = 0.037) and greater thermal difference between dorsum of wrist and third finger (p = 0.036) and between hands (p = 0.0001) versus controls, regardless of the motor laterality. Both tests evidenced an adequate capacity to differentiate between groups: in the non-immersed hand, the PD patients did not show the normal cooling pattern or final thermal overshoot observed in controls (F = 5.29; p = 0.001), and there was an AUC of 0.897 (95%CI 0.796-0.998) for this cooling; in the immersed hand, thermal recovery at 6 min post-immersion was lesser in patients (29 ± 17% vs. 55 ± 28%, p = 0.002), with an AUC of 0.810 (95%CI 0.662-0.958). PD patients reveal abnormal skin thermal responses in thermography with cold stress test, suggesting cutaneous autonomic dysfunction. This simple technique may be useful to evaluate autonomic dysfunction in PD. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... lesion? • What are the different types of abnormal Pap test results? • What testing is needed after an abnormal ... that could lead to cancer. Screening includes the Pap test and, for some women, testing for a virus ...

  6. MR imaging of abnormal synovial processes

    International Nuclear Information System (INIS)

    Quinn, S.F.; Sanchez, R.; Murray, W.T.; Silbiger, M.L.; Ogden, J.; Cochran, C.

    1987-01-01

    MR imaging can directly image abnormal synovium. The authors reviewed over 50 cases with abnormal synovial processes. The abnormalities include Baker cysts, semimembranous bursitis, chronic shoulder bursitis, peroneal tendon ganglion cyst, periarticular abscesses, thickened synovium from rheumatoid and septic arthritis, and synovial hypertrophy secondary to Legg-Calve-Perthes disease. MR imaging has proved invaluable in identifying abnormal synovium, defining the extent and, to a limited degree, characterizing its makeup

  7. Abnormal visuomotor processing in schizophrenia

    Directory of Open Access Journals (Sweden)

    Siân E. Robson

    2016-01-01

    Full Text Available Subtle disturbances of visual and motor function are known features of schizophrenia and can greatly impact quality of life; however, few studies investigate these abnormalities using simple visuomotor stimuli. In healthy people, electrophysiological data show that beta band oscillations in sensorimotor cortex decrease during movement execution (event-related beta desynchronisation (ERBD, then increase above baseline for a short time after the movement (post-movement beta rebound (PMBR; whilst in visual cortex, gamma oscillations are increased throughout stimulus presentation. In this study, we used a self-paced visuomotor paradigm and magnetoencephalography (MEG to contrast these responses in patients with schizophrenia and control volunteers. We found significant reductions in the peak-to-peak change in amplitude from ERBD to PMBR in schizophrenia compared with controls. This effect was strongest in patients who made fewer movements, whereas beta was not modulated by movement in controls. There was no significant difference in the amplitude of visual gamma between patients and controls. These data demonstrate that clear abnormalities in basic sensorimotor processing in schizophrenia can be observed using a very simple MEG paradigm.

  8. Operator training for the abnormal

    International Nuclear Information System (INIS)

    Marzec, R.J.

    1977-01-01

    Training of nuclear power plant control room operators, on actions to be taken for an abnormal event, has classically been limited to discussion, on-shift and/or during requalification training classes, of symptoms, logical thought processes, systems analysis, and operator experience. The prerequisites for these discussions are a common technical vocabulary, and a minimum basic comprehension of nuclear power plant fundamentals, plant component theory of operation, system configuration, system control philosophy and operating procedures. Nuclear power plant control room operators are not the only personnel who are or should be involved in these discussions. The shift supervisors, operations management, and auxiliary equipment operators require continuing training in abnormal operations, as well. More in-depth training is necessary for shift supervisors and control room operators. The availability of vendor simulators has improved the effectiveness of training efforts for these individuals to some extent by displaying typical situations and plant performance characteristics and by providing a degree of ''hands on'' experience. The evolution of in-depth training with these simulators is reviewed

  9. Analysis of Computational Fluid Dynamics and Particle Image Velocimetry Models of Distal-End Side-to-Side and End-to-Side Anastomoses for Coronary Artery Bypass Grafting in a Pulsatile Flow.

    Science.gov (United States)

    Shintani, Yoshiko; Iino, Kenji; Yamamoto, Yoshitaka; Kato, Hiroki; Takemura, Hirofumi; Kiwata, Takahiro

    2017-12-25

    Intimal hyperplasia (IH) is a major cause of graft failure. Hemodynamic factors such as stagnation and disturbed blood flow are involved in IH formation. The aim of this study is to perform a comparative analysis of distal-end side-to-side (deSTS) and end-to-side (ETS) anastomoses using computational fluid dynamics (CFD) after validating the results via particle image velocimetry (PIV).Methods and Results:We investigated the characteristics of our target flow fields using CFD under steady and pulsatile flows. CFD via PIV under steady flow in a 10-times-actual-size model was validated. The CFD analysis revealed a recirculation zone in the heel region in the deSTS and ETS anastomoses and at the distal end of the graft, and just distal to the toe of the host artery in the deSTS anastomoses. The recirculation zone sizes changed with the phase shift. We found regions of low wall shear stress and high oscillating shear index in the same areas. The PIV and CFD results were similar. It was demonstrated that the hemodynamic characteristics of CFD and PIV is the difference between the deSTS and ETS anastomoses; that is, the deSTS flow peripheral to the distal end of the graft, at the distal end and just distal to the toe of the host artery is involved in the IH formation.

  10. Index Driven Price Pressure in Corporate Bonds

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens

    Inclusion and exclusion of bonds from major indices are information-free, monthly events. At these events, liquidity providers get a significant abnormal return by trading against index trackers. The return is highest for bonds that are excluded because of a recent downgrade with a one-day return...

  11. Abnormal Event Detection Using Local Sparse Representation

    DEFF Research Database (Denmark)

    Ren, Huamin; Moeslund, Thomas B.

    2014-01-01

    We propose to detect abnormal events via a sparse subspace clustering algorithm. Unlike most existing approaches, which search for optimized normal bases and detect abnormality based on least square error or reconstruction error from the learned normal patterns, we propose an abnormality...... measurement based on the difference between the normal space and local space. Specifically, we provide a reasonable normal bases through repeated K spectral clustering. Then for each testing feature we first use temporal neighbors to form a local space. An abnormal event is found if any abnormal feature...

  12. Abnormal Returns and Contrarian Strategies

    Directory of Open Access Journals (Sweden)

    Ivana Dall'Agnol

    2003-12-01

    Full Text Available We test the hypothesis that strategies which are long on portfolios of looser stocks and short on portfolios of winner stocks generate abnormal returns in Brazil. This type of evidence for the US stock market was interpreted by The Bondt and Thaler (1985 as reflecting systematic evaluation mistakes caused by investors overreaction to news related to the firm performance. We found evidence of contrarian strategies profitability for horizons from 3 months to 3 years in a sample of stock returns from BOVESPA and SOMA from 1986 to 2000. The strategies are more profitable for shorter horizons. Therefore, there was no trace of the momentum effect found by Jagadeesh and Titman (1993 for the same horizons with US data. There are remaing unexplained positive returns for contrarian strategies after accounting for risk, size, and liquidity. We also found that the strategy profitability is reduced after the Real Plan, which suggests that the Brazilian stock market became more efficient after inflation stabilization.

  13. Genetic and infectious profiles influence cerebrospinal fluid IgG abnormality in Japanese multiple sclerosis patients.

    Directory of Open Access Journals (Sweden)

    Satoshi Yoshimura

    Full Text Available BACKGROUND: Abnormal intrathecal synthesis of IgG, reflected by cerebrospinal fluid (CSF oligoclonal IgG bands (OBs and increased IgG index, is much less frequently observed in Japanese multiple sclerosis (MS cohorts compared with Western cohorts. We aimed to clarify whether genetic and common infectious backgrounds influence CSF IgG abnormality in Japanese MS patients. METHODOLOGY: We analyzed HLA-DRB1 alleles, and IgG antibodies against Chlamydia pneumoniae, Helicobacter pylori, Epstein-Barr virus nuclear antigen (EBNA, and varicella zoster virus (VZV in 94 patients with MS and 367 unrelated healthy controls (HCs. We defined CSF IgG abnormality as the presence of CSF OBs and/or increased IgG index (>0.658. PRINCIPAL FINDINGS: CSF IgG abnormality was found in 59 of 94 (62.8% MS patients. CSF IgG abnormality-positive patients had a significantly higher frequency of brain MRI lesions meeting the Barkhof criteria compared with abnormality-negative patients. Compared with HCs, CSF IgG abnormality-positive MS patients showed a significantly higher frequency of DRB1 1501, whereas CSF IgG abnormality-negative patients had a significantly higher frequency of DRB1 0405. CSF IgG abnormality-positive MS patients had a significantly higher frequency of anti-C. pneumoniae IgG antibodies compared with CSF IgG abnormality-negative MS patients, although there was no difference in the frequency of anti-C. pneumoniae IgG antibodies between HCs and total MS patients. Compared with HCs, anti-H. pylori IgG antibodies were detected significantly less frequently in the total MS patients, especially in CSF IgG abnormality-negative MS patients. The frequencies of antibodies against EBNA and VZV did not differ significantly among the groups. CONCLUSIONS: CSF IgG abnormality is associated with Western MS-like brain MRI features. DRB1 1501 and C. pneumoniae infection confer CSF IgG abnormality, while DRB1 0405 and H. pylori infection are positively and negatively

  14. Effects of transdermal testosterone gel or an aromatase inhibitor on serum concentration and pulsatility of growth hormone in older men with age-related low testosterone.

    Science.gov (United States)

    Dias, Jenny Pena; Veldhuis, Johannes D; Carlson, Olga; Shardell, Michelle; Chia, Chee W; Melvin, Denise; Egan, Josephine M; Basaria, Shehzad

    2017-04-01

    Growth hormone is the major regulator of growth and body composition. Pulsatile GH secretion declines exponentially with age. Testosterone replacement is being increasingly offered to older men with age-related low testosterone. Testosterone administration has been shown to stimulate GH secretion. However, little is known about the effect of testosterone aromatization to estradiol on GH pulsatility and its impact on IGF-1 in older men. This randomized controlled proof-of-concept trial investigated the relative effects of testosterone and estradiol on GH pulsatility and IGF-1 in older men with low testosterone. Thirty-seven men, ≥65years with total testosterone testosterone gel (TT), 1mg oral aromatase inhibitor (AI) or placebo daily for 12months. Primary outcome was deconvolution and approximate entropy analyses of pulsatile including basal and entropic modes of secretion performed at baseline and 3months. Secondary outcomes included IGF-1 evaluated at baseline, 3 and 6months. At 3months, mean GH and in IGF-1 were similar between the three groups. At 6months, IGF-1 significantly increased by Δ 15.3±10.3ng/ml in the TT-group compared to placebo (P=0.03). Both intervention groups significantly increased GH pulse frequency (TT-group, P=0.04; AI-group, P=0.05) compared to placebo. The GH secretory-burst mode (duration) significantly decreased in the TT-group (P=0.0018) compared to placebo while it remained unchanged in the AI-group (P=0.059). In older men, testosterone increases GH pulse frequency while the aromatization to estradiol is involved in the rise of IGF-1 levels. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Abnormal Cerebrovascular Reactivity in Patients with Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    Carlos Henrique Ferreira Camargo

    2015-01-01

    Full Text Available Background. Orthostatic hypotension (OH is an important nonmotor manifestation of Parkinson’s disease (PD. Changes in cerebrovascular reactivity may contribute to this manifestation and can be monitored using transcranial Doppler. Objective. To identify possible changes in cerebrovascular reactivity in patients with OH. Methods. Twenty-two individuals were selected and divided into three groups: with and without OH and controls. Transcranial Doppler was used to assess basal mean blood flow velocity, postapnea mean blood flow velocity, percentage increase in mean blood flow velocity, and cerebrovascular reactivity as measured by the breath-holding index. Results. PD patients had lower values of basal velocity (p=0.019, postapnea velocity (p=0.0015, percentage increase in velocity (p=0.039, and breath-holding index (p=0.04 than the controls. Patients with OH had higher values of basal velocity (p=0.09 and postapnea velocity (p=0.19 but lower values of percentage increase in velocity (p=0.22 and breath-holding index (p=0.32 than patients without OH. Conclusions. PD patients present with abnormalities in a compensatory mechanism that regulates cerebral blood flow. OH could be an indicator of these abnormalities.

  16. Beneficial Effect of Short Pretransplant Period of Hypothermic Pulsatile Perfusion of the Warm-Ischemic Kidney after Cold Storage: Experimental Study.

    Science.gov (United States)

    Lázaro, Alberto; Humanes, Blanca; Jado, Juan Carlos; Mojena, Marina; González-Nicolás, María Ángeles; Del Cañizo, Juan Francisco; Tejedor, Alberto; Lledó-García, Enrique

    2016-01-01

    Warm ischemia (WI) produces a significant deleterious effect in potential kidney grafts. Hypothermic machine perfusion (HMP) seems to improve immediate graft function after transplant. Our aim was to analyze the effect of short pretransplant periods of pulsatile HMP on histology and renal injury in warm-ischemic kidneys. Twelve minipigs were used. WI was achieved in the right kidney by applying a vascular clamp for 45 min. After nephrectomy, autotransplant was performed following one of two strategies: cold storage of the kidneys or cold storage combined with perfusion in pulsatile HMP. The graft was removed early to study renal morphology, inflammation (fibrosis), and apoptosis. Proinflammatory activity and fibrosis were less pronounced after cold storage of the kidneys with HMP than after cold storage only. The use of HMP also decreased apoptosis compared with cold storage only. The detrimental effects on cells of an initial and prolonged period of WI seem to improve with a preservation protocol that includes a short period of pulsatile HMP after cold storage and immediately before the transplant, in comparison with cold storage only.

  17. Are Abnormal Yolk Sac Characteristics Important Factors in Abortion Rates?

    Directory of Open Access Journals (Sweden)

    Sanam Moradan

    2012-01-01

    Full Text Available Background: This study was undertaken to determine if there were different abortionrates between normal and abnormal yolk sacs.Materials and Methods: In this cohort study, the yolk sac characteristics of 193 consecutivepregnant women, of 5-6.5 weeks gestation, with normal body mass index (BMI were prospectivelyevaluated. All patients underwent two-dimensional transvaginal ultrasonography, whichwas performed by the same sonographer. We considered the following yolk sac characteristicsas normal for classification: diameter: 2-5 mm; round shape; absence of degenerative changes;equal number with embryos; echogenic rim and hypoechoic center. Yolk sacs that had diameterssmaller than 2 mm or larger than 5 mm; a shape that was not round (i.e., oval or distorted;the presence of degenerative changes; hyper- or hypo-echogenic rim; hyperechoic center andunequal number with embryos were considered abnormal. Based on the above classification,patients were divided into two groups, study (abnormal yolk sac and control (normal yolksac. The study group contained 22 cases and the control group consisted of 164 cases. The primaryoutcome measure was the abortion rate between both groups. Chi-square and students’ttest were used for data analysis.Results: A total of 193 cases were evaluated. We excluded 2 cases. Among the remaining191 cases, 22 (11.51% had abnormal yolk sacs of which spontaneous abortion occurredin 14 (63.63% cases. In the control group, out of 169 (89.49% cases, spontaneous abortionwas noted in 6 (3.55%. There was a statistically significant difference in abortionrates between the two groups (p=0.000.Conclusion: According to the results of this study, it is obvious that abnormal yolk saccharacteristics are associated with spontaneous abortion.

  18. Looking for a more useful Atherogenic Index for Nigerians | Josephs ...

    African Journals Online (AJOL)

    ... and none of them had abnormal lipid ratio. Sixty percent of hypertensives had positive AIP. Normotensives had only negative AIP values. The AIP therefore holds promise as a better index of atherogenicity than the cholesterol ratios or absolute lipid status. Keywords: Atherogenic index; esterification rate; Nigerian African ...

  19. Hemostatic abnormalities in liver cirrhosis

    Directory of Open Access Journals (Sweden)

    Kendal YALÇIN

    2009-06-01

    Full Text Available In this study, 44 patients with liver cirrhosis were investigated for hemostatic parameters. Patients with spontaneous bacterial peritonitis, hepatocellular carcinoma, hepatorenal syndrome and cholestatic liver diseases were excluded. Patients were classified by Child-Pugh criterion and according to this 4 patients were in Class A, 20 in Class B and 20 in C. Regarding to these results, it was aimed to investigate the haematological disturbances in liver cirrhotic patients.In the result there was a correlation between activated partial thromboplastin time, serum iron, ferritin, transferrin, haptoglobin and Child-Pugh classification. Besides there was no correlation between prothrombin time, factor 8 and 9, protein C and S, anti-thrombin 3, fibrinogen, fibrin degradation products, serum iron binding capacity, hemoglobin, leukocyte, mean corpuscular volume and Child-Pugh classification.There were significant difference, in terms of AST, ferritin, haptoglobulin, sex and presence of ascites between groups (p0.05. In the summary, we have found correlation between hemostatic abnormalities and disease activity and clinical prognosis in patients with liver cirrhosis which is important in the management of these patients. This is also important for identification of liver transplant candidiates earlier.

  20. Biochemical abnormalities in Pearson syndrome.

    Science.gov (United States)

    Crippa, Beatrice Letizia; Leon, Eyby; Calhoun, Amy; Lowichik, Amy; Pasquali, Marzia; Longo, Nicola

    2015-03-01

    Pearson marrow-pancreas syndrome is a multisystem mitochondrial disorder characterized by bone marrow failure and pancreatic insufficiency. Children who survive the severe bone marrow dysfunction in childhood develop Kearns-Sayre syndrome later in life. Here we report on four new cases with this condition and define their biochemical abnormalities. Three out of four patients presented with failure to thrive, with most of them having normal development and head size. All patients had evidence of bone marrow involvement that spontaneously improved in three out of four patients. Unique findings in our patients were acute pancreatitis (one out of four), renal Fanconi syndrome (present in all patients, but symptomatic only in one), and an unusual organic aciduria with 3-hydroxyisobutyric aciduria in one patient. Biochemical analysis indicated low levels of plasma citrulline and arginine, despite low-normal ammonia levels. Regression analysis indicated a significant correlation between each intermediate of the urea cycle and the next, except between ornithine and citrulline. This suggested that the reaction catalyzed by ornithine transcarbamylase (that converts ornithine to citrulline) might not be very efficient in patients with Pearson syndrome. In view of low-normal ammonia levels, we hypothesize that ammonia and carbamylphosphate could be diverted from the urea cycle to the synthesis of nucleotides in patients with Pearson syndrome and possibly other mitochondrial disorders. © 2015 Wiley Periodicals, Inc.

  1. Evaluation of Chromosomal Abnormalities and Common ...

    African Journals Online (AJOL)

    Evaluation of Chromosomal Abnormalities and Common Trombophilic Mutations in Cases with Recurrent Miscarriage. Ahmet Karatas, Recep Eroz, Mustafa Albayrak, Tulay Ozlu, Bulent Cakmak, Fatih Keskin ...

  2. Zumbido pulsátil: tratamento com clonazepan e propranolol Pulsatile tinnitus: treatment with clonazepam and propranolol

    Directory of Open Access Journals (Sweden)

    Sergio Albertino

    2005-02-01

    Full Text Available O zumbido pulsátil sincrônico com os batimentos cardíacos é pouco freqüente, sendo de etiologia tanto vascular arterial (malformações, fístulas artério-venosas ou venosa (anormalidades do bulbo jugular, tumor glômico jugular ou timpânico. A identificação precoce da etiologia é essencial para que a terapêutica adequada possa ser instituída. A angioressonância possibilita a identificação de alterações vasculares com maior precisão. Relatamos um caso onde, após o diagnóstico de uma alteração vascular arterial, foi instituído o tratamento com propranolol e clonazepam, com melhora da sintomatologia.Pulsatile tinnitus synchronous with heartbeat is rare and normally has vascular origin: arterial (malformation, arterial anatomical variation or venous (aberrant jugular bulb, glomus tumors, tympanic glomus tumor. Early etiology identification is essential for appropriate treatment to be established. Magnetic angioresonance makes the vascular identification possible and precise. We report a case of arterial anatomical variation in which the treatment was propranolol and clonazepam, showing tinnitus improvement.

  3. Fluid dynamic characterization of a polymeric heart valve prototype (Poli-Valve) tested under continuous and pulsatile flow conditions.

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura

    2015-11-01

    Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.

  4. Experimental and theoretical investigations of Lantana camara oil diffusion from polyacrylonitrile membrane for pulsatile drug delivery system.

    Science.gov (United States)

    Verma, Vivek; Balasubramanian, K

    2014-08-01

    Porous composite membrane of polyacrylonitrile (PAN) and Lantana camara essential oil was synthesized by solvent casting method. Stability of oil in PAN solution was measured by XiGo nano tool indicating constant relaxation time of 1487 time/s. Pore size of few microns confirmed by electron microscopy was supported by atomic force microscopy indicating roughness factor of 0.9 nm. Contact angle of 2° inveterates superhydrophilicity of the composite membrane. Membrane showed excellent antibacterial activity against both Gram-positive Bacillus subtilis and Gram-negative Escherichia coli with a 7-10mm zone of inhibition. In vitro release of Lantana oil from the composite membrane was carried out in isotonic phosphate buffer solution (pH=7.4). Lantana oil was released for 9h, lag time of 3h with constant 33% release confirmed PAN membranes as potential system for pulsatile drug delivery applications. Diffusion of E-caryophyllene (antibacterial component of oil) which was studied through molecular simulation using Material Studio software ensued diffusion coefficient value of 1.11∗10(-9) m(2)/s. Biocompatibility of the composite membrane was assessed by mouse embryonic fibroblast cell line (NIH 3T3) through MTT assay indicating more than 91% viable cell even at 200 μg/mL concentration. Such membranes can be efficiently used in biomedical applications as antibacterial and antifungal agent. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Mechanically robust dual responsive water dispersible-graphene based conductive elastomeric hydrogel for tunable pulsatile drug release.

    Science.gov (United States)

    Ganguly, Sayan; Ray, Debes; Das, Poushali; Maity, Priti Prasanna; Mondal, Subhadip; Aswal, V K; Dhara, Santanu; Das, Narayan Ch

    2018-04-01

    Nanohybrid hydrogels based on pristine graphene with enhanced toughness and dual responsive drug delivery feature is opening a new era for smart materials. Here pristine graphene hydrogels are synthesized by in situ free radical polymerization where graphene platelets are the nanobuiliding blocks to withstand external stress and shows reversible ductility. Such uniqueness is a mere reflection of rubber-like elasticity on the hydrogels. These nanobuilding blocks serve also the extensive physisorption which enhances the physical crosslinking inside the gel matrix. Besides the pH-responsive drug release features, these hydrogels are also implemented as a pulsatile drug delivery device. The electric responsive drug release behaviours are noticed and hypothesized by the formation of conducting network in the polyelectrolytic hydrogel matrix. The hydrogels are also tested as good biocompatibility and feasible cell-attachment during live-dead cell adhesion study. The drug release characteristics can also be tuned by adjusting the conducting filler loading into the gel matrix. As of our knowledge, this type of hydrogels with rubber-like consistency, high mechanical property, tunable and dual responsive drug delivery feature and very good human cell compatible is the first to report. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Calculation of wall shear stress in left coronary artery bifurcation for pulsatile flow using two-dimensional computational fluid dynamics.

    Science.gov (United States)

    Smith, Sahid; Austin, Shawn; Wesson, G Dale; Moore, Carl A

    2006-01-01

    The onset of coronary heart disease may be governed by distribution and magnitude of hemodynamic shear stress in the coronary arteries. This study numerically examines pulsatile blood flow through the left coronary artery system. A triphasic waveform is employed to simulate pulsating flow. Five non-Newtonian models, as well as the usual Newtonian model, are used to describe the viscous shear-thinning behavior of blood. It is concluded that when using computational fluid dynamics (CFD) to numerically investigate blood velocity profiles within small arteries, such the coronary artery system examined in this work, great care should be taken in choosing a blood viscosity model. It is suggested that the generalized power law model be the viscous shear thinning model of choice. When using CFD to investigate only patterns of wall shear stresses, the model selection is not as crucial and the simple Newtonian model will suffice but when the magnitude of WSS is of great importance, as in the case of the determining the development of coronary artery disease, the model selection is key.

  7. Leptin levels and luteinizing hormone pulsatility in normal cycling women and their relationship to daily changes in metabolic rate.

    Science.gov (United States)

    Fenichel, Rebecca M; Dominguez, Jennifer E; Mayer, Laurel; Walsh, B Timothy; Boozer, Carol; Warren, Michelle P

    2008-10-01

    To determine whether leptin and LH secretion in normal women is related to changes in metabolic rate. Academic medical center. PATIENT(S) AND DESIGN: Ten young women with normal weight and menses were studied during the early follicular phase. Leptin and LH levels were sampled every 15 minutes over a 24-hour period. Metabolic rate was frequently sampled using indirect calorimetry. Luteinizing hormone pulsatility was analyzed using a Cluster Program analysis. None. Leptin, LH, and metabolic rate levels. All subjects demonstrated a diurnal leptin curve. Luteinizing hormone pulses were increased in amplitude and slower after the leptin peak. The average (+/-SE) number of LH pulses per 6 hours slowed from 4.30 +/- 0.42 to 3.00 +/- 0.42 pulses after the leptin peak, whereas pulse amplitude increased from 1.64 +/- 0.26 to 2.51 +/- 0.42 mIU/mL after the leptin peak. The LH interpulse interval increased from 85.1 +/- 3.64 minutes to 108.8 +/- 10.26 minutes after the leptin peak. Metabolic rate began to drop approximately 4-6 hours before leptin levels peaked, going from 1.66 +/- 0.24 to 1.15 +/- 0.04 kcal/min after the leptin peak. There is a significant association between the timing of the leptin peak, the nightly slowing of LH pulses, and the fall in metabolic rate, suggesting a metabolic cycle in normal individuals.

  8. Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

    Science.gov (United States)

    Roszelle, Breigh N; Deutsch, Steven; Manning, Keefe B

    2010-02-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV) as a flow visualization technique, however the small size and high curvature of the PVAD make other tools such as stereoscopic PIV impractical. In order to test the reliability of the 2D results, we perform a pseudo-3D PIV study using planes both parallel and normal to the diaphragm employing a mock circulatory loop containing a viscoelastic fluid that mimics 40% hematocrit blood. We find that while the third component of velocity is extremely helpful to a physical understanding of the flow, particularly of the diastolic jet and the development of a desired rotational pattern, the flow data taken parallel to the diaphragm is sufficient to describe the wall shear rates, a critical aspect to the study of thrombosis and design of such pumps.

  9. Quality by Design Empowered Development and Optimisation of Time-Controlled Pulsatile Release Platform Formulation Employing Compression Coating Technology.

    Science.gov (United States)

    Patadia, Riddhish; Vora, Chintan; Mittal, Karan; Mashru, Rajashree C

    2017-05-01

    The research was envisaged for development of time-controlled pulsatile release (PR) platform formulation to facilitate management of early morning chronological attacks. The development was started using prednisone as a model drug wherein core tablets were prepared using direct compression method and subsequently compression-coated with ethylcellulose (EC)-hydroxypropyl methylcellulose (HPMC) excipient blend. Initially, quality target product profile was established and risk assessment was performed using failure mode and effect analysis. In an endeavour to accomplish the objective, central composite design was employed as a design of experiment (DoE) tool. Optimised compression-coated tablet (CCT) exhibited 4-6 h lag time followed by burst release profile under variegated dissolution conditions viz. multi-media, change in apparatus/agitation and biorelevant media. Afterwards, five different drugs, i.e. methylprednisolone, diclofenac sodium, diltiazem hydrochloride, nifedipine and lornoxicam, were one-by-one incorporated into the optimised prednisone formula with replacement of former drug. Change in drug precipitated the issues like poor solubility and flow property which were respectively resolved through formulation of solid dispersion and preparation of active pharmaceutical ingredient (API) granules. Albeit, all drug CCTs exhibited desired release profile similar to prednisone CCTs. In nutshell, tour de force of research epitomised the objective of incorporating diverse drug molecules and penultimately obtaining robust release profile at varying dissolution conditions.

  10. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  11. The fetal cerebro-placental ratio in diabetic pregnancies is influenced more by the umbilical artery rather than middle cerebral artery pulsatility index.

    Science.gov (United States)

    Gibbons, Anthea; Flatley, Christopher; Kumar, Sailesh

    2017-04-01

    This study aimed to assess the relationship between the cerebro-placental ratio (CPR) and intrapartum and perinatal outcomes in pregnancies complicated by pre-existing insulin dependent diabetes (pT1DM) mellitus, pre-existing non-insulin dependent diabetes mellitus (pT2DM) and gestational diabetes mellitus (GDM). This was a retrospective cohort study of 1281 women with diabetes mellitus birthing at the Mater Mothers' Hospital in Brisbane between 2007 and 2015. The CPR in non-anomalous singleton fetuses was measured between 34+0 and 36+6 weeks gestation and compared between types of DM treatment groups and correlated with intrapartum and perinatal outcomes. Of the study cohort, 9.7% (124/1281) had pT1DM, 5.3% (68/1281) had pT2DM and 85.0% (1089/1281) had GDM. Of women with pT2DM and GDM, 61.8% (42/68) and 28.9% (315/1089) respectively, required insulin during pregnancy. Women with pT1DM had an increased odds of having a CPR 90th centile (OR 2.69, 95% CI: 1.60-4.39, p=0.0001) was higher in the pT1DM cohort. There was however no significant difference in the mean MCA PI between the three groups. Stratification by CPR centiles (<10th centile vs. ≥10th centile) demonstrated a lower birth weight in the CPR <10th centile cohort for all DM categories. The proportion of neonates with birth weights <10th centile were higher in the CPR <10th centile cohort with the GDM cohort having an odds ratio of 8.28 (95% CI 4.22-16.13, p<0.0001) of this complication. The CPR <10th centile cohort also had a greater proportion of adverse composite neonatal outcome regardless of type of DM. Regardless of the type of DM, a low CPR was associated with poorer neonatal outcomes. Women with pT1DM also had the highest mean UA PI and lowest mean CPR despite no difference in the mean MCA PI between the three groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Adenotonsillar hypertrophy as a risk factor of dentofacial abnormality in Korean children.

    Science.gov (United States)

    Kim, Dong-Kyu; Rhee, Chae Seo; Yun, Pil-Young; Kim, Jeong-Whun

    2015-11-01

    No studies for the role of adenotonsillar hypertrophy in development of dentofacial abnormalities have been performed in Asian pediatric population. Thus, we aimed to investigate the relationship between adenotonsillar hypertrophy and dentofacial abnormalities in Korean children. The present study included consecutive children who visited a pediatric clinic for sleep-disordered breathing due to habitual mouth breathing, snoring or sleep apnea. Their palatine tonsils and adenoids were graded by oropharyngeal endoscopy and lateral cephalometry. Anterior open bite, posterior crossbite, and Angle's class malocclusions were evaluated for dentofacial abnormality. The receiver-operating characteristic curve analysis was used to identify age cutoffs to predict dentofacial abnormality. A total of 1,083 children were included. The presence of adenotonsillar hypertrophy was significantly correlated with the prevalence of dentofacial abnormality [adjusted odds ratio = 4.587, 95% CI (2.747-7.658)] after adjusting age, sex, body mass index, allergy, and Korean version of obstructive sleep apnea-18 score. The cutoff age associated with dentofacial abnormality was 5.5 years (sensitivity = 75.5%, specificity = 67%) in the children with adenotonsillar hypertrophy and 6.5 years (sensitivity = 70.6%, specificity = 57%) in those without adenotonsillar hypertrophy. In conclusion, adenotonsillar hypertrophy may be a risk factor for dentofacial abnormalities in Korean children and early surgical intervention could be considered with regards to dentofacial abnormality.

  13. Repolarization abnormalities in the newborn.

    Science.gov (United States)

    Schwartz, Peter J; Stramba-Badiale, Marco

    2010-06-01

    The recognition of ventricular repolarization abnormalities in the newborn carries several and significant implications, because it calls attention to the possibility of dealing with an infant affected by the long QT syndrome (LQTS). This article provides key elements for the correct measurement of the QT interval in newborns and succinctly reviews some aspects of the disease. It gives normative values on the QT interval distribution in the first month of life based on a prospective study in more than 44,000 infants. It shows the probability, based on the QTc observed in two recordings, to find disease-causing mutations. The data indicate clearly that widespread electrocardiographic screening in the newborn allows early identification of most, if not all, the infants affected by LQTS with marked QT prolongation and thus of those at higher risk for life-threatening arrhythmias and sudden death. Through the affected infants, it becomes possible to identify the family members affected by LQTS, including the "silent mutation carriers"; our study shows that disease-causing mutations are found in 51% of the family members. Because early recognition leads to the implementation of effective preventive strategies, it follows that electrocardiographic screening will avoid preventable deaths either in the first year of life when they are usually labeled as "sudden infant death syndrome" or later in life. The case is made for medicolegal implications whenever neonatologists and pediatricians fail to inform the parents of a newborn child of the prevalence of LQTS (one in 2000), of the effectiveness of existing therapies, and of the diagnosis with a simple electrocardiogram.

  14. Nail abnormalities in patients with vitiligo.

    Science.gov (United States)

    Topal, Ilteris Oguz; Gungor, Sule; Kocaturk, Ozgur Emek; Duman, Hatice; Durmuscan, Mustafa

    2016-01-01

    Vitiligo is an acquired pigmentary skin disorder affecting 0.1-4% of the general population. The nails may be affected in patients with an autoimmune disease such as psoriasis, and in those with alopecia areata. It has been suggested that nail abnormalities should be apparent in vitiligo patients. We sought to document the frequency and clinical presentation of nail abnormalities in vitiligo patients compared to healthy volunteers. We also examined the correlations between nail abnormalities and various clinical parameters. This study included 100 vitiligo patients and 100 healthy subjects. Full medical histories were collected from the subjects, who underwent thorough general and nail examinations. All nail changes were noted. In the event of clinical suspicion of a fungal infection, additional mycological investigations were performed. Nail abnormalities were more prevalent in the patients (78%) than in the controls (55%) (p=0.001). Longitudinal ridging was the most common finding (42%), followed by (in descending order): leukonychia, an absent lunula, onycholysis, nail bed pallor, onychomycosis, splinter hemorrhage and nail plate thinning. The frequency of longitudinal ridging was significantly higher in patients than in controls (pNail abnormalities were more prevalent in vitiligo patients than in controls. Systematic examination of the nails in such patients is useful because nail abnormalities are frequent. However, the causes of such abnormalities require further study. Longitudinal ridging and leukonychia were the most common abnormalities observed in this study.

  15. Effects of theophylline administration and intracranial abnormalities ...

    African Journals Online (AJOL)

    Objective: To determine effects of theophylline therapy for recurrent apnoea of prematurity and abnormal early (within the first 24 hours) cranial ultrasound abnormalities on protective neck turning response in preterm infants. Design: A cross sectional descriptive study. Setting: The Neonatal Unit of Hammersmith Hospital, ...

  16. Prevalence of biochemical and immunological abnormalities in ...

    African Journals Online (AJOL)

    Tile prevalence of biochemical and immunological abnormalities was studied in a group of 256 patients with rheumatoid arthritis (104 coloureds, 100 whites and 52 blacks). The most common biochemical abnormalities detected were a reduction in the serum creatinine value (43,4%), raised globulins (39,7%), raised serum ...

  17. First Trimester Ultrasound Screening for Congenital Abnormalities ...

    African Journals Online (AJOL)

    approach used, especially with the introduction of first trimester ultrasound as a reliable screening method. Objective: To give a comprehensive review of the basis for first trimester ultrasound screening for congenital abnormalities, it's utilization in the prenatal screening for chromosomal, structural and genetic abnormalities ...

  18. An Abnormal Psychology Community Based Interview Assignment

    Science.gov (United States)

    White, Geoffry D.

    1977-01-01

    A course option in abnormal psychology involves students in interviewing and observing the activities of individuals in the off-campus community who are concerned with some aspect of abnormal psychology. The technique generates student interest in the field when they interview people about topics such as drug abuse, transsexualism, and abuse of…

  19. Dental abnormalities and oral health in patients with Hypophosphatemic rickets

    Directory of Open Access Journals (Sweden)

    Melissa Almeida Souza

    2010-01-01

    Full Text Available INTRODUCTION: Hypophosphatemic rickets represents a group of heritable renal disorders of phosphate characterized by hypophosphatemia, normal or low serum 1,25 (OH2 vitamin D and calcium levels. Hypophosphatemia is associated to interglobular dentine and an enlarged pulp chambers. AIM: Our goal was to verify the dental abnormalities and the oral health condition in these patients. MATERIAL AND METHODS: Prospective study of oral conditions in patients with Hypophosphatemic rickets. This report employed a simple method to be easily reproducible: oral clinical exam and radiographic evaluation. RESULTS: Fourteen patients were studied, 5 males, median age of 11years (4 to 26. Occlusion defects (85,7% and enamel hypoplasia (57,1% were significant more frequently than dental abscesses (one patient. We observed enlarged pulp chambers in 43% of the patients and hypoplasia and dentin abnormalities in 14,3%. We could not detect a significant correlation between dental abnormalities and delayed treatment (p>0,05. DMFT index for 6 to 12 years patients (n = 12 showed that the oral health is unsatisfactory (mean DMFT = 5. CONCLUSIONS: Patients with Hypophosphatemic Rickets frequently present dental alterations and these are not completely recovered with the treatment, unless dental abscess and they need a periodical oral examination.

  20. Relationship of functional leg-length discrepancy to abnormal pronation.

    Science.gov (United States)

    Rothbart, Brian A

    2006-01-01

    The objective of this study was to determine whether a correlation exists between abnormal pronation and functional leg-length discrepancies. Visual assessment and a pelvic thrust maneuver were used to identify the functionally short leg in 56 indigenous Mexicans (20 males and 36 females; mean age, 33 years; mean weight, 59 kg; and mean height, 1.60 m). The Foot Posture Index was used with a modified stance position to identify the more pronated foot. The posterosuperior iliac spines were used to identify the "relative" position of the innominate bones. The raw data obtained from this study were evaluated using the McNemar test for paired proportions. A significant positive correlation was found between abnormal pronation and hip position and between hip position and functional leg-length discrepancy. These results are consistent with a theoretical ascending dysfunctional pelvic model: Abnormal pronation pulls the innominate bones anteriorly (forward); anterior rotation of the innominate bones shifts the acetabula posteriorly and cephalad (backward and upward); and this shift in the acetabula hyperextends the knees and shortens the legs, with the shortest leg corresponding to the most pronated foot.

  1. Report to Congress on abnormal occurrences

    International Nuclear Information System (INIS)

    1993-06-01

    Section 208 of the Energy Reorganization Act of 1974 identifies an abnormal occurrence as an unscheduled incident or event that the Nuclear Regulatory Commission determines to be significant from the standpoint of public health and safety and requires a quarterly report of such events to be made to Congress. This report covers the period January through March 1993. There is one abnormal occurrence at a nuclear power plant disposed in this report that involved a steam generator tube rupture at Palo Verde Unit 2, and none for fuel cycle facilities. Three abnormal occurrences involving medical misadminstrations (two therapeutic and one diagnostic) at NRC-licensed facilities are also discussed in this report. No abnormal occurrences were reported by NRC's Agreement States. The report also contains information updating previously reported abnormal occurrences

  2. Chromosomal abnormalities in patients with sperm disorders

    Directory of Open Access Journals (Sweden)

    L. Y. Pylyp

    2013-02-01

    Full Text Available Chromosomal abnormalities are among the most common genetic causes of spermatogenic disruptions. Carriers of chromosomal abnormalities are at increased risk of infertility, miscarriage or birth of a child with unbalanced karyotype due to the production of unbalanced gametes. The natural selection against chromosomally abnormal sperm usually prevents fertilization with sperm barring in cases of serious chromosomal abnormalities. However, assisted reproductive technologies in general and intracytoplasmic sperm injection in particular, enable the transmission of chromosomal abnormalities to the progeny. Therefore, cytogenetic studies are important in patients with male factor infertility before assisted reproduction treatment. The purpose of the current study was to investigate the types and frequencies of chromosomal abnormalities in 724 patients with infertility and to estimate the risk of chromosomal abnormalities detection in subgroups of patients depending on the severity of spermatogenic disruption, aiming at identifying groups of patients in need of cytogenetic studies. Karyotype analysis was performed in 724 blood samples of men attending infertility clinic. Chromosomal preparation was performed by standard techniques. At least 20 GTG-banded metaphase plates with the resolution from 450 to 750 bands per haploid set were analysed in each case. When chromosomal mosaicism was suspected, this number was increased to 50. Abnormal karyotypes were observed in 48 (6.6% patients, including 67% of autosomal abnormalities and 33% of gonosomal abnormalities. Autosomal abnormalities were represented by structural rearrangements. Reciprocal translocations were the most common type of structural chromosomal abnormalities in the studied group, detected with the frequency of 2.6% (n = 19, followed by Robertsonian translocation, observed with the frequency of 1.2% (n = 9. The frequency of inversions was 0.6% (n = 4. Gonosomal abnormalities included 14 cases

  3. Hemolymph circulation in insect sensory appendages: functional mechanics of antennal accessory pulsatile organs (auxiliary hearts) in the mosquito Anopheles gambiae.

    Science.gov (United States)

    Boppana, Sushma; Hillyer, Julián F

    2014-09-01

    Mosquito antennae provide sensory input that modulates host-seeking, mating and oviposition behaviors. Thus, mosquitoes must ensure the efficient transport of molecules into and out of these appendages. To accomplish this, mosquitoes and other insects have evolved antennal accessory pulsatile organs (APOs) that drive hemolymph into the antennal space. This study characterizes the structural mechanics of hemolymph propulsion throughout the antennae of Anopheles gambiae. Using intravital video imaging, we show that mosquitoes possess paired antennal APOs that are located on each side of the head's dorsal midline. They are situated between the frons and the vertex in an area that is dorsal to the antenna but ventral to the medial-most region of the compound eyes. Antennal APOs contract in synchrony at 1 Hz, which is 45% slower than the heart. By means of histology and intravital imaging, we show that each antennal APO propels hemolymph into the antenna through an antennal vessel that traverses the length of the appendage and has an effective diameter of 1-2 μm. When hemolymph reaches the end of the appendage, it is discharged into the antennal hemocoel and returns to the head. Because a narrow vessel empties into a larger cavity, hemolymph travels up the antenna at 0.2 mm s(-1) but reduces its velocity by 75% as it returns to the head. Finally, treatment of mosquitoes with the anesthetic agent FlyNap (triethylamine) increases both antennal APO and heart contraction rates. In summary, this study presents a comprehensive functional characterization of circulatory physiology in the mosquito antennae. © 2014. Published by The Company of Biologists Ltd.

  4. Superior semicircular canal dehiscence in relation to the superior petrosal sinus: a potential cause of pulsatile tinnitus

    International Nuclear Information System (INIS)

    Liu, Z.; Bi, W.; Li, J.; Li, Q.; Dong, C.; Zhao, P.; Lv, H.; Wang, Z.

    2015-01-01

    Aim: To examine the association between superior semicircular canal dehiscence (SSCD) and pulsatile tinnitus (PT). Materials and methods: Two SSCD groups included 408 unilateral persistent PT patients, and 511 controls undergoing head and neck dual-phase contrast-enhanced computed tomography (DP-CECT) for reasons other than PT. The prevalence of type I (no the superior petrosal sinus running through the dehiscence) and type II (superior semicircular canal dehiscence in relation to the superior petrosal sinus) SSCD was analysed using chi-square test. Results: SSCD was identified in 5.1% (21/408) of PT ears, significantly different from 2% (8/408) of non-PT ears and 0.7% (7/1022) of controls. There was no significant difference in SSCD prevalence between non-PT ears in the PT group and controls. In the PT group, 15/21 ears were type II SSCD; 6/21 ears were type I. Fifteen combined non-PT and control ears with SSCD included two type II and 13 type I SSCD. The prevalence of type II SSCD in PT ears was significantly higher than that of non-PT ears in both groups, and the prevalence of type I SSCD in PT ears was similar to that of non-PT ears in both groups. Conclusion: Compared with type I SSCD, there may be a causal relationship between type II SSCD and PT. -- Highlights: •The prevalence of type II SSCD in PT ears was significantly higher than that in non-PT ears in both the PT group and controls. •The prevalence of type I SSCD was similar among the PT ears and non-PT ears. •The superior petrosal sinus running through the dehiscence may be essential for SSCD to induce PT. •Venous phase CT images with bone window settings is the modality method to differentiate type II from type I SSCD

  5. Association between idiopathic intracranial hypertension and sigmoid sinus dehiscence/diverticulum with pulsatile tinnitus: a retrospective imaging study

    International Nuclear Information System (INIS)

    Zhaohui, Liu; Qing, Li; Cheng, Dong; Xiao, Wang; Xiaoyi, Han; Pengfei, Zhao; Han, Lv; Zhenchang, Wang

    2015-01-01

    The mechanism of occurrence of sigmoid sinus dehiscence/diverticulum (SSDD) in pulsatile tinnitus (PT) patients remains under debate. Its association with idiopathic intracranial hypertension (IIH) lacks evidence, which is important for therapeutic planning and improving the clinical outcome. This study aimed to evaluate the association between SSDD and IIH by comparing the prevalence of several established imaging features of IIH between PT patients with SSDD and healthy volunteers. Thirty-three unilateral PT patients with SSDD identified on CT images and 33 age- and sex-matched healthy volunteers underwent T1-weighted volumetric magnetic resonance imaging (MRI). The optic nerve, pituitary gland, transverse sinus, and ventricles were assessed. The prevalence of established IIH imaging features was compared between the two groups. Furthermore, the PT patients were divided into two subgroups: PT patients with dehiscence only and PT patients with diverticulum. The same statistical analysis was performed on each pathophysiologic entity respectively. The PT patients with SSDD showed a significantly higher prevalence of empty sella (P < 0.001), flattened posterior sclera (P = 0.001), vertical tortuosity of the optic nerve (P = 0.001), protrusion of the optic nerve (P = 0.006), transverse sinus stenosis (P = 0.011), and distension of the optic nerve sheath (P = 0.000). There were no significant differences between the PT and control groups in the maximum widths of the third and fourth ventricles and the lateral ventricle size. In contrast to controls, the imaging findings persisted in both of pathophysiologic entities, except for transverse sinus stenosis. Several IIH imaging features occur more frequently in PT patients with SSDD than in healthy individuals, which suggests a potential correlation between SSDD with PT and IIH. (orig.)

  6. Association between idiopathic intracranial hypertension and sigmoid sinus dehiscence/diverticulum with pulsatile tinnitus: a retrospective imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zhaohui, Liu; Qing, Li [Capital Medical University, Beijing Tongren Hospital, Department of Radiology, Beijing (China); Cheng, Dong; Xiao, Wang; Xiaoyi, Han; Pengfei, Zhao; Han, Lv; Zhenchang, Wang [Capital Medical University, Beijing Friendship Hospital, Department of Radiology, Beijing (China)

    2015-07-15

    The mechanism of occurrence of sigmoid sinus dehiscence/diverticulum (SSDD) in pulsatile tinnitus (PT) patients remains under debate. Its association with idiopathic intracranial hypertension (IIH) lacks evidence, which is important for therapeutic planning and improving the clinical outcome. This study aimed to evaluate the association between SSDD and IIH by comparing the prevalence of several established imaging features of IIH between PT patients with SSDD and healthy volunteers. Thirty-three unilateral PT patients with SSDD identified on CT images and 33 age- and sex-matched healthy volunteers underwent T1-weighted volumetric magnetic resonance imaging (MRI). The optic nerve, pituitary gland, transverse sinus, and ventricles were assessed. The prevalence of established IIH imaging features was compared between the two groups. Furthermore, the PT patients were divided into two subgroups: PT patients with dehiscence only and PT patients with diverticulum. The same statistical analysis was performed on each pathophysiologic entity respectively. The PT patients with SSDD showed a significantly higher prevalence of empty sella (P < 0.001), flattened posterior sclera (P = 0.001), vertical tortuosity of the optic nerve (P = 0.001), protrusion of the optic nerve (P = 0.006), transverse sinus stenosis (P = 0.011), and distension of the optic nerve sheath (P = 0.000). There were no significant differences between the PT and control groups in the maximum widths of the third and fourth ventricles and the lateral ventricle size. In contrast to controls, the imaging findings persisted in both of pathophysiologic entities, except for transverse sinus stenosis. Several IIH imaging features occur more frequently in PT patients with SSDD than in healthy individuals, which suggests a potential correlation between SSDD with PT and IIH. (orig.)

  7. Pulsatile blood flow in human bone assessed by laser-Doppler flowmetry and the interpretation of photoplethysmographic signals

    International Nuclear Information System (INIS)

    Binzoni, Tiziano; Tchernin, David; Hyacinthe, Jean-Noël; Van De Ville, Dimitri; Richiardi, Jonas

    2013-01-01

    Human bone blood flow, mean blood speed and the number of moving red blood cells were assessed (in arbitrary units), as a function of time, during one cardiac cycle. The measurements were obtained non-invasively on five volunteers by laser-Doppler flowmetry at large interoptode spacing. The investigated bones included: patella, clavicle, tibial diaphysis and tibial malleolus. As hypothesized, we found that in all bones the number of moving cells remains constant during cardiac cycles. Therefore, we concluded that the pulsatile nature of blood flow must be completely determined by the mean blood speed and not by changes in blood volume (vessels dilation). Based on these results, it is finally demonstrated using a mathematical model (derived from the radiative transport theory) that photoplethysmographic (PPG) pulsations observed by others in the literature, cannot be generated by oscillations in blood oxygen saturation, which is physiologically linked to blood speed. In fact, possible oxygen saturation changes during pulsations decrease the amplitude of PPG pulsations due to specific features of the PPG light source. It is shown that a variation in blood oxygen saturation of 3% may induce a negative change of ∼1% in the PPG signal. It is concluded that PPG pulsations are determined by periodic ‘positive’ changes of the reduced scattering coefficient of the tissue and/or the absorption coefficient at constant blood volume. No explicit experimental PPG measurements have been performed. As a by-product of this study, an estimation of the arterial pulse wave velocity obtained from the analysis of the blood flow pulsations give a value of 7.8 m s −1 (95% confidence interval of the sample mean distribution: [6.7, 9.5] m s −1 ), which is perfectly compatible with data in the literature. We hope that this note will contribute to a better understanding of PPG signals and to further develop the domain of the vascular physiology of human bone. (note)

  8. Image-based biomechanical modeling of aortic wall stress and vessel deformation: response to pulsatile arterial pressure simulations

    Science.gov (United States)

    Hazer, Dilana; Bauer, Miriam; Unterhinninghofen, Roland; Dillmann, Rüdiger; Richter, Götz-M.

    2008-03-01

    Image-based modeling of cardiovascular biomechanics may be very helpful for patients with aortic aneurysms to predict the risk of rupture and evaluate the necessity of a surgical intervention. In order to generate a reliable support it is necessary to develop exact patient-specific models that simulate biomechanical parameters and provide individual structural analysis of the state of fatigue and characterize this to the potential of rupture of the aortic wall. The patient-specific geometry used here originates from a CT scan of an Abdominal Aortic Aneurysm (AAA). The computations are based on the Finite Element Method (FEM) and simulate the wall stress distribution and the vessel deformation. The wall transient boundary conditions are based on real time-dependent pressure simulations obtained from a previous computational fluid dynamics study. The physiological wall material properties consider a nonlinear hyperelastic constitutive model, based on realistic ex-vivo analysis of the aneurismal arterial tissue. The results showed complex deformation and stress distribution on the AAA wall. The maximum stresses occurred at the systole and are found around the aneurismal bulge in regions close to inflection points. Biomechanical modeling based on medical images and coupled with patient-specific hemodynamics allows analysing and quantifying the effects of dilatation of the arterial wall due to the pulsatile aortic pressure. It provides a physical and realistic insight into the wall mechanics and enables predictive simulations of AAA growth and assessment of rupture. Further development integrating endovascular models would help evaluating non-invasively individual treatment strategies for optimal placement and improved device design.

  9. Does the Pulsatile Preservation Machine Have Any Impact in the Discard Rate of Kidneys From Older Donors After Brain Death?

    Science.gov (United States)

    Paredes-Zapata, D; Ruiz-Arranz, A; Rodriguez-Villar, C; Roque-Arda, R; Peri-Cusi, L; Saavedra-Escobar, S; Vizcaino-Elias, F; Garcia-Rodriguez, X; Bohils-Valle, M; Rodriguez-Peña, S; Quijada-Martorell, M; Gonzalez-Rodriguez, J-J; Oppenheimer-Salinas, F; Alcaraz-Asensio, A; Adalia-Bartolome, R

    2015-10-01

    Donors after brain death (DBD) older than 60 years have become 46.8% of our current activity, with higher risk of renal discard rate (RDR). Assessment of kidney suitability requires complementary strategies: macroscopic evaluation, kidney biopsy score (KBS), and renal hemodynamic evaluation with the Pulsatile Perfusion Machine (PPM). Descriptive, cross-sectional, comparative study of kidneys procured and RDR, comparing 3 time periods: 2000 to June 2004, when only KBS were used; July 2004 to 2008 (introduction of PPM and learning period); and 2009 to 2013 (experienced use of PPM). Transplantation criteria were KBS 70 mL/min. Between 2000 and 2013, a 59.2% reduction in DBD kidneys was observed. However, older kidneys had an increase from 33.5% to 46.8%. The RDR had increased, comparing the first to the third period from 25.4% to 38.3%. However, the RDR was lower when kidneys were evaluated with PPM than those evaluated only with KBS and preserved in cold storage (CS) (21.4% versus 43.7%). There was a significant difference in cold ischemia time, because CS kidney was grafted before PPM. During the third period, more kidneys with KBS ≥4 were assigned to PPM. Notwithstanding the decrease in DBD-procured kidneys and the increase in older kidneys during last period, the use of PPM allowed low DR compared with CS. A bias in the results of PPM could be generated when kidneys with higher KBS were excluded from PPM. The use of KBS only to decide acceptance could preclude the use of an additional tool to evaluate suitability. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The T-peak–T-end Interval as a Marker of Repolarization Abnormality

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer A.; Graff, Claus; Kanters, Jørgen K.

    2015-01-01

    BACKGROUND AND OBJECTIVE: The T-peak to T-end (TpTe) interval has been suggested as an index of transmural dispersion and as a marker of drug-induced abnormal repolarization. In this study, we investigate the relation between TpTe and the QT interval. METHODS: Electrocardiograms (ECGs) from five...

  11. Numerically abnormal chromosome constitutions in humans

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    Chapter 24, discusses numerically abnormal chromosome constitutions in humans. This involves abnormalities of human chromosome number, including polyploidy (when the number of sets of chromosomes increases) and aneuploidy (when the number of individual normal chromosomes changes). Chapter sections discuss the following chromosomal abnormalities: human triploids, imprinting and uniparental disomy, human tetraploids, hydatidiform moles, anomalies caused by chromosomal imbalance, 13 trisomy (D{sub 1} trisomy, Patau syndrome), 21 trisomy (Down syndrome), 18 trisomy syndrome (Edwards syndrome), other autosomal aneuploidy syndromes, and spontaneous abortions. The chapter concludes with remarks on the nonrandom participation of chromosomes in trisomy. 69 refs., 3 figs., 4 tabs.

  12. Prediction of heart abnormality using MLP network

    Science.gov (United States)

    Hashim, Fakroul Ridzuan; Januar, Yulni; Mat, Muhammad Hadzren; Rizman, Zairi Ismael; Awang, Mat Kamil

    2018-02-01

    Heart abnormality does not choose gender, age and races when it strikes. With no warning signs or symptoms, it can result to a sudden death of the patient. Generally, heart's irregular electrical activity is defined as heart abnormality. Via implementation of Multilayer Perceptron (MLP) network, this paper tries to develop a program that allows the detection of heart abnormality activity. Utilizing several training algorithms with Purelin activation function, an amount of heartbeat signals received through the electrocardiogram (ECG) will be employed to condition the MLP network.

  13. Computational fluid dynamics characterization of pulsatile flow in central and Sano shunts connected to the pulmonary arteries: importance of graft angulation on shear stress-induced, platelet-mediated thrombosis.

    Science.gov (United States)

    Ascuitto, Robert; Ross-Ascuitto, Nancy; Guillot, Martin; Celestin, Carey

    2017-09-01

    Central (aorta) and Sano (right ventricle)-to-pulmonary artery (PA) shunts, palliative operations for infants with complex heart defects, can develop life-threatening thrombosis. We employed computational fluid dynamics (CFD) to study pulsatile flow in these shunts, with the goal to identify haemodynamic characteristics conducive to thrombus formation. CFD, using the finite volume method with cardiac catheterization data, and computer simulations, based on angiography, were employed to determine flow-velocity field, wall shear stress (WSS) profile and oscillatory shear index (OSI). At prominent angulation, in central shunts (4 and 3.5 mm), WSS reached 245 and 123 (Pascal-Pa), peak systole and 137 and 46 Pa, end diastole; and, in Sano shunts (5 and 6 mm), WSS attained 203 and 133 Pa, peak systole and 1.6 and 1.5 Pa, end diastole. Counter-rotating flow vortices augmented WSS. These high WSSs can promote platelet aggregation, leading to thrombus formation. The OSIs averaged 0.39, indicative of multidirectional shearing forces. Shunt burden was assessed by averaging WSS, over its luminal area and the cardiac cycle. For the central shunts, these WSSs were 73.0 and 67.2 Pa; whereas, for the Sano shunts, 34.9 and 19.6 Pa. For modified Blalock-Taussig shunts (4 and 3.5 mm), the averaged WSSs were significantly lower at 26.0 and 27.5 Pa, respectively. CFD modelling is an important tool to determine blood flow behaviour in shunts. Graft angulation presents a risk for shear stress-induced, platelet- mediated thrombosis, which is more likely to occur in elongated central than in Sano shunts. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Pulsatile gonadotropin-releasing hormone therapy is associated with earlier spermatogenesis compared to combined gonadotropin therapy in patients with congenital hypogonadotropic hypogonadism

    Directory of Open Access Journals (Sweden)

    Jiang-Feng Mao

    2017-01-01

    Full Text Available Both pulsatile gonadotropin-releasing hormone (GnRH infusion and combined gonadotropin therapy (human chorionic gonadotropin and human menopausal gonadotropin [HCG/HMG] are effective to induce spermatogenesis in male patients with congenital hypogonadotropic hypogonadism (CHH. However, evidence is lacking as to which treatment strategy is better. This retrospective cohort study included 202 patients with CHH: twenty had received pulsatile GnRH and 182 had received HCG/HMG. Patients had received therapy for at least 12 months. The total follow-up time was 15.6 ± 5.0 months (range: 12-27 months for the GnRH group and 28.7 ± 13.0 months (range: 12-66 months for the HCG/HMG group. The median time to first sperm appearance was 6 months (95% confidence interval [CI]: 1.6-10.4 in the GnRH group versus 18 months (95% CI: 16.4-20.0 in the HCG/HMG group (P 1 × 10 6 ml−1 was 43.7% ± 20.4% (16 samples in the GnRH group versus 43.2% ± 18.1% (153 samples in the HCG/HMG group (P = 0.921. Notably, during follow-up, the GnRH group had lower serum testosterone levels than the HCG/HMG group (8.3 ± 4.6 vs 16.2 ± 8.2 nmol l−1 , P < 0.001. Our study found that pulsatile GnRH therapy was associated with earlier spermatogenesis and larger testicular size compared to combined gonadotropin therapy. Additional prospective randomized studies would be required to confirm these findings.

  15. Pulsatile gonadotropin-releasing hormone therapy is associated with earlier spermatogenesis compared to combined gonadotropin therapy in patients with congenital hypogonadotropic hypogonadism.

    Science.gov (United States)

    Mao, Jiang-Feng; Liu, Zhao-Xiang; Nie, Min; Wang, Xi; Xu, Hong-Li; Huang, Bing-Kun; Zheng, Jun-Jie; Min, Le; Kaiser, Ursula Brigitte; Wu, Xue-Yan

    2017-01-01

    Both pulsatile gonadotropin-releasing hormone (GnRH) infusion and combined gonadotropin therapy (human chorionic gonadotropin and human menopausal gonadotropin [HCG/HMG]) are effective to induce spermatogenesis in male patients with congenital hypogonadotropic hypogonadism (CHH). However, evidence is lacking as to which treatment strategy is better. This retrospective cohort study included 202 patients with CHH: twenty had received pulsatile GnRH and 182 had received HCG/HMG. Patients had received therapy for at least 12 months. The total follow-up time was 15.6 ± 5.0 months (range: 12-27 months) for the GnRH group and 28.7 ± 13.0 months (range: 12-66 months) for the HCG/HMG group. The median time to first sperm appearance was 6 months (95% confidence interval [CI]: 1.6-10.4) in the GnRH group versus 18 months (95% CI: 16.4-20.0) in the HCG/HMG group (P 1 × 10 6 ml-1 was 43.7% ± 20.4% (16 samples) in the GnRH group versus 43.2% ± 18.1% (153 samples) in the HCG/HMG group (P = 0.921). Notably, during follow-up, the GnRH group had lower serum testosterone levels than the HCG/HMG group (8.3 ± 4.6 vs 16.2 ± 8.2 nmol l-1 , P < 0.001). Our study found that pulsatile GnRH therapy was associated with earlier spermatogenesis and larger testicular size compared to combined gonadotropin therapy. Additional prospective randomized studies would be required to confirm these findings.

  16. Differential Effects of Continuous Exposure to the Investigational Metastin/Kisspeptin Analog TAK-683 on Pulsatile and Surge Mode Secretion of Luteinizing Hormone in Ovariectomized Goats

    Science.gov (United States)

    TANAKA, Tomomi; OHKURA, Satoshi; WAKABAYASHI, Yoshihiro; KUROIWA, Takenobu; NAGAI, Kiyosuke; ENDO, Natsumi; TANAKA, Akira; MATSUI, Hisanori; KUSAKA, Masami; OKAMURA, Hiroaki

    2013-01-01

    Abstract The aim of the present study was to determine if the estradiol-induced luteinizing hormone (LH) surge is influenced by the constant exposure to TAK-683, an investigational metastin/kisspeptin analog, that had been established to depress the pulsatile gonadotropin-releasing hormone (GnRH) and LH secretion in goats. Ovariectomized goats subcutaneously received TAK-683 (TAK-683 group, n=6) or vehicle (control group, n=6) constantly via subcutaneous implantation of an osmotic pump. Five days after the start of the treatment, estradiol was infused intravenously in both groups to evaluate the effects on the LH surge. Blood samples were collected at 6-min intervals for 4 h prior to the initiation of either the TAK-683 treatment or the estradiol infusion, to determine the profiles of pulsatile LH secretion. They were also collected at 2-h intervals from –4 h to 32 h after the start of estradiol infusion for analysis of LH surges. The frequency and mean concentrations of LH pulses in the TAK-683 group were remarkably suppressed 5 days after the start of TAK-683 treatment compared with those of the control group (P<0.05). On the other hand, a clear LH surge was observed in all animals of both groups. There were no significant differences in the LH concentrations for surge peak and the peak time of the LH surge between the TAK-683 and control groups. These findings suggest that the effects of continuous exposure to kisspeptin or its analog on the mechanism(s) that regulates the pulsatile and surge mode secretion of GnRH/LH are different in goats. PMID:24047956

  17. EJSCREEN Indexes 2015 Public

    Data.gov (United States)

    U.S. Environmental Protection Agency — There is an EJ Index for each environmental indicator. There are eight EJ Indexes in EJSCREEN reflecting the 8 environmental indicators. The EJ Index names are:...

  18. EJSCREEN Indexes 2016 Public

    Data.gov (United States)

    U.S. Environmental Protection Agency — There is an EJ Index for each environmental indicator. There are eleven EJ Indexes in EJSCREEN reflecting the 11 environmental indicators. The EJ Index names are:...

  19. A new kind of auxiliary heart in insects: functional morphology and neuronal control of the accessory pulsatile organs of the cricket ovipositor

    Science.gov (United States)

    2014-01-01

    Introduction In insects, the pumping of the dorsal heart causes circulation of hemolymph throughout the central body cavity, but not within the interior of long body appendages. Hemolymph exchange in these dead-end structures is accomplished by special flow-guiding structures and/or autonomous pulsatile organs (“auxiliary hearts”). In this paper accessory pulsatile organs for an insect ovipositor are described for the first time. We studied these organs in females of the cricket Acheta domesticus by analyzing their functional morphology, neuroanatomy and physiological control. Results The lumen of the four long ovipositor valves is subdivided by longitudinal septa of connective tissue into efferent and afferent hemolymph sinuses which are confluent distally. The countercurrent flow in these sinuses is effected by pulsatile organs which are located at the bases of the ovipositor valves. Each of the four organs consists of a pumping chamber which is compressed by rhythmically contracting muscles. The morphology of the paired organs is laterally mirrored, and there are differences in some details between the dorsal and ventral organs. The compression of the pumping chambers of each valve pair occurs with a left-right alternating rhythm with a frequency of 0.2 to 0.5 Hz and is synchronized between the dorsal and ventral organs. The more anteriorly located genital chamber shows rhythmical lateral movements simultaneous to those of the ovipositor pulsatile organs and probably supports the hemolymph exchange in the abdominal apex region. The left-right alternating rhythm is produced by a central pattern generator located in the terminal ganglion. It requires no sensory feedback for its output since it persists in the completely isolated ganglion. Rhythm-modulating and rhythm-resetting interneurons are identified in the terminal ganglion. Conclusion The circulatory organs of the cricket ovipositor have a unique functional morphology. The pumping apparatus at the base

  20. [Dental abnormalities after treatment for childhood cancer].

    Science.gov (United States)

    Mladosievičová, B; Jurkovič, R; Izakovičová Hollá, L

    2015-01-01

    Childhood cancer therapy often increases the risk of dental complications, such as tooth and roots agenesis, microdontia, abnormal development of tooth enamel, increased risk of cavity and other abnormalities. In a comparison with other late adverse effects of chemotherapy, radiotherapy and hematopoietic stem cell transplantion, a relative small number of clinical stud-ies observing patients for more than two years after completion of anticancer treatment was published. In this article, we review the incidence of dental abnormalities caused by commonly used anticancer treatment modalities as well as discuss their risk factors. Early identification of high-risk patients, early detection and management of dental abnormalities and better education of patients or their guardians, may have an impact on quality of life of cancer survivors.

  1. On two abnormal sharks from Gujarat

    Digital Repository Service at National Institute of Oceanography (India)

    Gopalan, U.K.

    The description of the two abnormal sharks, Carchariaswalbeehmi and Eulamia dussumieri collected from Gujarat, India, is given Of these C walbeehmi was double-headed The other shark E dussumieri had thumb snouted albino...

  2. Video Traffic Analysis for Abnormal Event Detection

    Science.gov (United States)

    2010-01-01

    We propose the use of video imaging sensors for the detection and classification of abnormal events to be used primarily for mitigation of traffic congestion. Successful detection of such events will allow for new road guidelines; for rapid deploymen...

  3. Low-set ears and pinna abnormalities

    Science.gov (United States)

    ... because they do not affect hearing. However, sometimes cosmetic surgery is recommended. Skin tags may be tied off, ... 5 years old. More severe abnormalities may require surgery for cosmetic reasons as well as for function. Surgery to ...

  4. Report to Congress on abnormal occurrences

    International Nuclear Information System (INIS)

    1990-10-01

    Section 208 of the Energy Reorganization Act of 1974 identifies an abnormal occurrence as an unscheduled incident or event that the Nuclear Regulatory Commission determines to be significant from the standpoint of public health or safety and requires a quarterly report of such events to be made to Congress. This report covers the period from April 1 through June 30, 1990. The report discusses six abnormal occurrences, none involving a nuclear power plant. There were five abnormal occurrences at NRC licensees: (1) deficiencies in brachytherapy program; (2) a radiation overexposure of a radiographer; (3) a medical diagnostic misadministration; (4) administration of iodine-131 to a lactating female with subsequent uptake by her infant; and (5) a medical therapy misadministration. An Agreement State (Arizona) reported an abnormal occurrence involving a medical diagnostic misadministration. The report also contains information that updates a previously reported occurrence

  5. Errata :Chromosomal Abnormalities in Couples with Recurrent ...

    African Journals Online (AJOL)

    Chromosomal Abnormalities in Couples with Recurrent Abortions in Lagos, Nigeria. Akinde OR, Daramola A O, Taiwo I A, Afolayan M O and Akinsola Af. Sonographic Mammary Gland Density Pattern in Women in Selected ommunities of Southern Nigeria.

  6. Video traffic analysis for abnormal event detection.

    Science.gov (United States)

    2010-01-01

    We propose the use of video imaging sensors for the detection and classification of abnormal events to : be used primarily for mitigation of traffic congestion. Successful detection of such events will allow for : new road guidelines; for rapid deplo...

  7. Prevalence of asymptomatic urinary abnormalities among adolescents

    Directory of Open Access Journals (Sweden)

    Mohamed Fouad

    2016-01-01

    Full Text Available To determine the prevalence of asymptomatic urinary abnormalities in adolescents, first morning clean mid-stream urine specimens were obtained from 2500 individuals and examined by dipstick and light microscopy. Adolescents with abnormal screening results were reexamined after two weeks and those who had abnormal results twice were subjected to systemic clinical examination and further clinical and laboratory investigations. Eight hundred and three (32.1% individuals had urinary abnormalities at the first screening, which significantly decreased to 345 (13.8% at the second screening, (P <0.001. Hematuria was the most common urinary abnormalities detected in 245 (9.8% adolescents who had persistent urine abnormalities; 228 (9.1% individuals had non glomerular hematuria. The hematuria was isolated in 150 (6% individuals, combined with leukocyturia in 83 (3.3% individuals, and combined with proteinuria in 12 (0.5% individuals. Leukocyturia was detected in 150 (6% of all studied adolescents; it was isolated in 39 (1.6% individuals and combined with proteinuria in 28 (1.1% of them. Asymp- tomatic bacteriuria was detected in 23 (0.9% of all studied adolescents; all the cases were females. Proteinuria was detected in 65 (2.6% of all the studied adolescents; 45 (1.8% indivi- duals had <0.5 g/day and twenty (0.8% individuals had 0.5-3 g/day. Asymptomatic urinary abnormalities were more common in males than females and adolescents from rural than urban areas (P <0.01 and (P <0.001, respectively. The present study found a high prevalence of asymptomatic urinary abnormalities among adolescents in our population.

  8. Abnormal ''Contamination' Levels On Garden Appliances

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Elmelech, V.; Pelled, O.; Tshuva, A.; Laichter, Y.

    1999-01-01

    During routine contamination checks we encountered an abnormal high level of Alpha and Beta emitting radioisotopes on working gloves of employees of the gardening department. It came out that the source was due to ''contamination'' levels on steering wheels of some gardening machines. In order to ensure that no real contamination of these workers was involved , a series of checks was started to identity the source of the abnormal levels found during monitoring

  9. Normal and Abnormal Behavior in Early Childhood

    OpenAIRE

    Spinner, Miriam R.

    1981-01-01

    Evaluation of normal and abnormal behavior in the period to three years of age involves many variables. Parental attitudes, determined by many factors such as previous childrearing experience, the bonding process, parental psychological status and parental temperament, often influence the labeling of behavior as normal or abnormal. This article describes the forms of crying, sleep and wakefulness, and affective responses from infancy to three years of age.

  10. Familial eccrine syringofibroadenomatosis with associated ophthalmologic abnormalities.

    Science.gov (United States)

    Chen, S; Palay, D; Templeton, S F

    1998-08-01

    Eccrine syringofibroadenoma (ESFA) is a rare benign adnexal tumor, generally with sporadic occurrence and not linked to other diseases. Only one familial occurrence of ESFA has been reported. We describe the familial occurrence of multiple ESFAs in a father and his two sons, all of whom also had similar eyelid abnormalities and progressive corneal scarring. This description of hereditary ESFA is the first to link ESFA with periocular and ocular abnormalities.

  11. [Hysteroscopic polypectomy, treatment of abnormal uterine bleeding].

    Science.gov (United States)

    de Los Rios, P José F; López, R Claudia; Cifuentes, P Carolina; Angulo, C Mónica; Palacios-Barahona, Arlex U

    2015-07-01

    To evaluate the effectiveness of the hysteroscopic polypectomy in terms of the decrease of the abnormal uterine bleeding. A cross-sectional and analytical study was done with patients to whom a hysteroscopic polypectomy was done for treating the abnormal uterine bleeding, between January 2009 and December 2013. The response to the treatment was evaluated via a survey given to the patients about the behavior of the abnormal uterine bleeding after the procedure and about overall satisfaction. The results were obtained after a hysteroscopic polypectomy done to 128 patients and were as follows. The average time from the polypectomy applied until the survey was 30.5 months, with a standard deviation of 18 months. 67.2% of the patients reported decreased abnormal uterine bleeding and the 32.8% reported a persistence of symptoms. On average 82.8% of the. patients were satisfied with the treatment. Bivariate and multivariate analysis showed no association between the variables studied and no improvement of abnormal uterine bleeding after surgery (polypectomy). There were no complications. Hysteroscopic polypectomy is a safe surgical treatment, which decreases on two of three patients the abnormal uterine bleeding in the presence of endometrial polyps, with an acceptable level of satisfaction.

  12. [Journal selection and indexing for Index Medicus and Chinese periodicals indexed in Index Medicus].

    Science.gov (United States)

    Zhou, Qing-Hui; Ling, Chang-Quan; Bai, Yu-Jin; Yin, Hui-Xia

    2005-01-01

    Index Medicus/MEDLINE/PubMed published by U. S. National Library of Medicine (NLM) is the most important and commonly used biomedical literature retrieval system in the world. According to the"List of Journals Indexed in Index Medicus (2004)", 4,098 journals are indexed for Index Medicus, including 70 journals from mainland China and Hong Kong and 9 journals from Taiwan. Journal of Chinese Integrative Medicine established in May, 2003 is indexed in Index Medicus in 2004. This article outlines the critical elements of journal selection for Index Medicus/MEDLINE and the journal selection process for indexing at NLM, and introduces some measures for the Journal of Chinese Integrative Medicine being indexed in Index Medicus/MEDLINE.

  13. MR angiography of stenosis and aneurysm models in the pulsatile flow: variation with imaging parameters and concentration of contrast media

    International Nuclear Information System (INIS)

    Park, Kyung Joo; Park, Jae Hyung; Lee, Hak Jong; Won, Hyung Jin; Lee, Dong Hyuk; Min, Byung Goo; Chang, Kee Hyun

    1997-01-01

    The image quality of magnetic resonance angiography (MRA) varies according to the imaging techniques applied and the parameters affected by blood flow patterns, as well as by the shape of the blood vessels. This study was designed to assess the influence on signal intensity and its distribution of the geometry of these vessels, the imaging parameters, and the concentration of contrast media in MRA of stenosis and aneurysm models. MRA was performed in stenosis and aneurysm models made of glass tubes, using pulsatile flow with viscosity and flow profile similar to those of blood. Slice and maximum intensity projection (MIP) images were obtained using various imaging techniques and parameters;there was variation in repetition time, flip angle, imaging planes, and concentrations of contrast media. On slice images of three-dimensional (3D) time-of-flight (TOF) techniques, flow signal intensity was measured at five locations in the models, and contrast ratio was calculated as the difference between flow signal intensity (SI) and background signal intensity (SIb) divided by background signal intensity or (SI-SIb)/SIb. MIP images obtained by various techniques and using various parameters were also analyzed, with emphasis in the stenosis model on demonstrated degree of stenosis, severity of signal void and image distortion, and in the aneurysm model, on degree of visualization, distortion of contour and distribution of signals. In 3D TOF, the shortest TR (36 msec) and the largest FA (50 deg ) resulted in the highest contrast ratio, but larger flip angles did not effectively demonstrate the demonstration of the peripheral part of the aneurysm. Loss of signal was most prominent in images of the stenosis model obtained with parallel or oblique planes to the flow direction. The two-dimensional TOF technique also caused signal void in stenosis, but precisely demonstrated the aneurysm, with dense opacification of the peripheral part. The phase contrast technique showed some

  14. Ocular abnormalities in healthy Standardbred foals.

    Science.gov (United States)

    Barsotti, Giovanni; Sgorbini, Micaela; Marmorini, Paola; Corazza, Michele

    2013-07-01

    To determine the prevalence and describe ocular abnormalities in healthy Standardbred foals within 48 h of birth. One hundred and two neonatal foals. All foals had an unassisted delivery. On the basis of physical examination and the results of hematological and biochemical parameters, all foals were unaffected by systemic diseases. A complete ophthalmic examination was performed within 48 h of birth. Foals with ocular hemorrhages were re-examined weekly until the abnormalities were resolved. 65/102 (63.7%) foals did not show ocular abnormalities, while in 37/102 (36.3%) cases, ocular abnormalities were present. Retinal and subconjunctival hemorrhages were recorded in 19/102 (18.6%), and in 13/102 (12.7%), respectively. In 4/102 (3.9%) animals, an entropion of the lower eyelid was present. Only one foal (1%) showed a congenital nuclear unilateral cataract. No other ocular abnormalities were detected. However, all foals showed various degrees of remnants of hyaloid system. One week after the first ocular examination, retinal hemorrhages had resolved in 100% of the eyes, whereas subconjunctival hemorrhages had disappeared in all eyes by the second week following the first examination. The acquired ocular lesions observed with relatively high frequency in the examined healthy Standardbred foals were ocular hemorrhages, which always showed a good outcome. Although these abnormalities were present at birth, they were not considered strictly congenital but likely acquired during parturition. Instead, congenital ocular abnormalities were rarely diagnosed, and the entropion of the lower eyelid was the most common disease in the breed. © 2012 American College of Veterinary Ophthalmologists.

  15. Detecting Kidney and Urinary Tract Abnormalities Before Birth

    Science.gov (United States)

    ... Guide Detecting Kidney and Urinary Tract Abnormalities Before Birth Print Email Ultrasound examinations are often done as ... What causes urinary tract abnormalities to occur before birth? In about one of 500 births, some abnormality ...

  16. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Mortele, Koenraad J. E-mail: kmortele@partners.org; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R

    2004-10-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established.

  17. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    International Nuclear Information System (INIS)

    Mortele, Koenraad J.; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R.

    2004-01-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established

  18. Viscosity-adjusted estimation of pressure head and pump flow with quasi-pulsatile modulation of rotary blood pump for a total artificial heart.

    Science.gov (United States)

    Yurimoto, Terumi; Hara, Shintaro; Isoyama, Takashi; Saito, Itsuro; Ono, Toshiya; Abe, Yusuke

    2016-09-01

    Estimation of pressure and flow has been an important subject for developing implantable artificial hearts. To realize real-time viscosity-adjusted estimation of pressure head and pump flow for a total artificial heart, we propose the table estimation method with quasi-pulsatile modulation of rotary blood pump in which systolic high flow and diastolic low flow phased are generated. The table estimation method utilizes three kinds of tables: viscosity, pressure and flow tables. Viscosity is estimated from the characteristic that differential value in motor speed between systolic and diastolic phases varies depending on viscosity. Potential of this estimation method was investigated using mock circulation system. Glycerin solution diluted with salty water was used to adjust viscosity of fluid. In verification of this method using continuous flow data, fairly good estimation could be possible when differential pulse width modulation (PWM) value of the motor between systolic and diastolic phases was high. In estimation under quasi-pulsatile condition, inertia correction was provided and fairly good estimation was possible when the differential PWM value was high, which was not different from the verification results using continuous flow data. In the experiment of real-time estimation applying moving average method to the estimated viscosity, fair estimation could be possible when the differential PWM value was high, showing that real-time viscosity-adjusted estimation of pressure head and pump flow would be possible with this novel estimation method when the differential PWM value would be set high.

  19. Effect of counter-pulsation control of a pulsatile left ventricular assist device on working load variations of the native heart.

    Science.gov (United States)

    Choi, Seong Wook; Nam, Kyoung Won; Lim, Ki Moo; Shim, Eun Bo; Won, Yong Soon; Woo, Heung Myong; Kwak, Ho Hyun; Noh, Mi Ryoung; Kim, In Young; Park, Sung Min

    2014-04-03

    When using a pulsatile left ventricular assist device (LVAD), it is important to reduce the cardiac load variations of the native heart because severe cardiac load variations can induce ventricular arrhythmia. In this study, we investigated the effect of counter-pulsation control of the LVAD on the reduction of cardiac load variation. A ventricular electrocardiogram-based counter-pulsation control algorithm for a LVAD was implemented, and the effects of counter-pulsation control of the LVAD on the reduction of the working load variations of the left ventricle were determined in three animal experiments. Deviations of the working load of the left ventricle were reduced by 51.3%, 67.9%, and 71.5% in each case, and the beat-to-beat variation rates in the working load were reduced by 84.8%, 82.7%, and 88.2% in each ease after counter-pulsation control. There were 3 to 12 premature ventricle contractions (PVCs) before counter-pulsation control, but no PVCs were observed during counter-pulsation control. Counter-pulsation control of the pulsatile LVAD can reduce severe cardiac load variations, but the average working load is not markedly affected by application of counter-pulsation control because it is also influenced by temporary cardiac outflow variations. We believe that counter-pulsation control of the LVAD can improve the long-term safety of heart failure patients equipped with LVADs.

  20. To Index or Not To Index.

    Science.gov (United States)

    Veenema, Fred

    1996-01-01

    Describes an experiment comparing the performance of an automatic full-text indexing software for personal computers (i.e., the Quick-Finder facility in WordPerfect 6.1 for Windows) with the human intellectual assignment of indexing terms to each document in a collection. Results are discussed in terms of ease of use, the time factor, and recall…

  1. Chromosomal abnormality in patients with secondary amenorrhea.

    Science.gov (United States)

    Safai, Akbar; Vasei, Mohammad; Attaranzadeh, Armin; Azad, Fariborz; Tabibi, Narjes

    2012-04-01

    Secondary amenorrhea is a condition in which there is cessation of menses after at least one menstruation. It is a symptom of different diseases, such as hormonal disturbances which range from pituitary to ovarian origin, as well as chromosomal abnormalities. Knowledge of the distinct cause of secondary amenorrhea is of tremendous benefit for the management and monitoring of patients. In this study, we determine the chromosomal abnormalities in patients with secondary amenorrhea in Southwest Iran. We selected 94 patients with secondary amenorrhea who referred to our Cytogenetic Ward from 2004 until 2009. For karyotyping, peripheral blood lymphocyte cultures were set up by conventional technique. In this study, 5.3% (n=5) of patients with secondary amenorrhea presented with chromosomal abnormalities, of which all contained an X element. The chromosomal abnormalities were: i) 45, X (n=1); ii) 47, XXX (n=1); iii) 45, X [13]/ 45, Xi(X)q[17] (n=1);  iv) 45, X[12]/46,X,+mar[12] (n=1); and v) 46,X,del(Xq)(q23q28) (n=1). Our study revealed that some causes of secondary amenorrhea could be due to chromosomal abnormalities. Therefore, cytogenetic studies should be important tests in the evaluation of patients with secondary amenorrhea.

  2. Cardiac abnormality prediction using HMLP network

    Science.gov (United States)

    Adnan, Ja'afar; Ahmad, K. A.; Mat, Muhamad Hadzren; Rizman, Zairi Ismael; Ahmad, Shahril

    2018-02-01

    Cardiac abnormality often occurs regardless of gender, age and races but depends on the lifestyle. This problem sometimes does not show any symptoms and usually detected once it already critical which lead to a sudden death to the patient. Basically, cardiac abnormality is the irregular electrical signal that generate by the pacemaker of the heart. This paper attempts to develop a program that can detect cardiac abnormality activity through implementation of Hybrid Multilayer Perceptron (HMLP) network. A certain amount of data of the heartbeat signals from the electrocardiogram (ECG) will be used in this project to train the MLP and HMLP network by using Modified Recursive Prediction Error (MRPE) algorithm and to test the network performance.

  3. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  4. Schizophrenia and abnormal brain network hubs.

    Science.gov (United States)

    Rubinov, Mikail; Bullmore, Ed

    2013-09-01

    Schizophrenia is a heterogeneous psychiatric disorder of unknown cause or characteristic pathology. Clinical neuroscientists increasingly postulate that schizophrenia is a disorder of brain network organization. In this article we discuss the conceptual framework of this dysconnection hypothesis, describe the predominant methodological paradigm for testing this hypothesis, and review recent evidence for disruption of central/hub brain regions, as a promising example of this hypothesis. We summarize studies of brain hubs in large-scale structural and functional brain networks and find strong evidence for network abnormalities of prefrontal hubs, and moderate evidence for network abnormalities of limbic, temporal, and parietal hubs. Future studies are needed to differentiate network dysfunction from previously observed gray- and white-matter abnormalities of these hubs, and to link endogenous network dysfunction phenotypes with perceptual, behavioral, and cognitive clinical phenotypes of schizophrenia.

  5. Folate metabolism abnormalities in autism: potential biomarkers.

    Science.gov (United States)

    Frye, Richard E; Slattery, John C; Quadros, Edward V

    2017-08-03

    Autism spectrum disorder (ASD) has been linked to abnormalities in folate metabolism. Polymorphisms in folate genes may act in complex polygenic ways to increase the risk of developing ASD. Autoantibodies that block folate transport into the brain have been associated with ASD and children with ASD and these autoantibodies respond to high doses of a reduced form of folate known as folinic acid (leucovorin calcium). Some of the same abnormalities are also found in mothers of children with ASD and supplementing folate during preconception and gestational periods reduces the risk to the offspring from developing ASD. These data suggest that folate pathway abnormalities may be a major metabolic disturbance underlying ASD that can be leveraged as biomarkers to improve symptoms and prevent ASD.

  6. Abnormal cervical cytology and health care use

    DEFF Research Database (Denmark)

    Frederiksen, Maria Eiholm; Baillet, Miguel Vázquez-Prada; Dugué, Pierre-Antoine

    2015-01-01

    OBJECTIVE: This study aimed to assess the long-term use of health care services in women with abnormal cytology results compared to women with normal cytology results. METHODS: We did a nationwide population-based study, using women aged 23 to 59years participating in the national organized...... cervical cancer screening program. We included a study population of 40,153 women with abnormal cytology (exposed) and 752,627 women with normal cytology (non-exposed). We retrieved data from the Danish Civil Registration System, the Danish Pathology Data Bank, the National Health Service, the National...... the "before" to the "after" period. This increase was significantly higher for exposed than non-exposed women regarding contacts to GP, admissions to hospitals, and drug use. CONCLUSION: Women with abnormal cytology results constitute a selected group with a higher health care use than other women even before...

  7. Abnormal Grain Growth Suppression in Aluminum Alloys

    Science.gov (United States)

    Hales, Stephen J. (Inventor); Claytor, Harold Dale (Inventor); Alexa, Joel A. (Inventor)

    2015-01-01

    The present invention provides a process for suppressing abnormal grain growth in friction stir welded aluminum alloys by inserting an intermediate annealing treatment ("IAT") after the welding step on the article. The IAT may be followed by a solution heat treatment (SHT) on the article under effectively high solution heat treatment conditions. In at least some embodiments, a deformation step is conducted on the article under effective spin-forming deformation conditions or under effective superplastic deformation conditions. The invention further provides a welded article having suppressed abnormal grain growth, prepared by the process above. Preferably the article is characterized with greater than about 90% reduction in area fraction abnormal grain growth in any friction-stir-welded nugget.

  8. Enhanced monitoring of abnormal emergency department demands

    KAUST Repository

    Harrou, Fouzi

    2016-06-13

    This paper presents a statistical technique for detecting signs of abnormal situation generated by the influx of patients at emergency department (ED). The monitoring strategy developed was able to provide early alert mechanisms in the event of abnormal situations caused by abnormal patient arrivals to the ED. More specifically, This work proposed the application of autoregressive moving average (ARMA) models combined with the generalized likelihood ratio (GLR) test for anomaly-detection. ARMA was used as the modelling framework of the ARMA-based GLR anomaly-detection methodology. The GLR test was applied to the uncorrelated residuals obtained from the ARMA model to detect anomalies when the data did not fit the reference ARMA model. The ARMA-based GLR hypothesis testing scheme was successfully applied to the practical data collected from the database of the pediatric emergency department (PED) at Lille regional hospital center, France. © 2015 IEEE.

  9. Report on Congress on abnormal occurrences

    International Nuclear Information System (INIS)

    1991-06-01

    Section 208 of the energy Reorganization Act of 1974 identifies an abnormal occurrence as an unscheduled incident or event that the Nuclear Regulatory Commission determines to be significant from the standpoint of public health or safety and requires a quarterly report of such events to be made to Congress. This report covers the period from January 1 through March 31, 1991. The report discusses six abnormal occurrences, none of which involved a nuclear power plant. Five of the events occurred at NRC-licensed facilities: one involved a significant degradation of plant safety at a nuclear fuel cycle facility, one involved a medical diagnostic misadministration, and three involved medical therapy misadministrations. An Agreement State (Arizona) reported one abnormal occurrence that involved medical therapy misadministrations

  10. Abnormal fetal head shape: aetiology and management

    DEFF Research Database (Denmark)

    Petersen, Olav Bjørn; David, Anna; Thomasson, Louise

    2007-01-01

    and define management pathways for fetuses with an abnormal skull shape. Methods: Our FMU databases were searched to ascertain all fetuses with an abnormal skull shape. Sonographic findings, diagnosis and outcome were reviewed. Results: Of the 370 cases identified, 31.6% were associated with spinabifida......Background: Abnormal head shape is an uncommon finding on prenatal ultrasound, often associated with breech presentation, spinabifida, aneuploidy or secondary to oligohydramnios or fetal position. Other aetiologies are rarer and may be more difficult to define. Objective: To determine the aetiology...... incidence of genetic syndromes, in the absence of a clear diagnosis, referral to a tertiary centre and genetic input is advised as detection of subtle sonographic features may aid diagnosis, allowing for targeted molecular analysis. An algorithm for management will be proposed....

  11. Osseous temporomandibular joint abnormalities in rheumatic disease

    International Nuclear Information System (INIS)

    Larheim, T.A.; Kolbenstvedt, A.; Rikshospitalet, Oslo

    1990-01-01

    Computed tomography (CT) of the temporomandibular joint (TMJ) was compared with hypocycloidal tomography in 30 joints of 15 adults with rheumatic disease. CT included 1.5 mm thick axial scans (at 1.0 mm intervals) with reformatted oblique sagittal and oblique coronal sections. Multisection (at 2.0 mm intervals) tomography included oblique sagittal and occasionally, oblique coronal sections. CT demonstrated bone abnormalities in 21 and tomography in 20 joints, indicating high agreement between the imaging modalities regarding number of abnormal TMJs. Bone structures were, however, better visualized by multiplanar CT due to superior contrast and spatial resolution particularly in the most lateral and medial parts of the joint, indicating superiority of CT for depicting subtle bony TMJ abnormalities in patients with rheumatic disease. (orig.)

  12. [Abnormal peripheral circulation in heart failure].

    Science.gov (United States)

    Cohen-Solal, A; Laperche, T; Caviezel, B; Dahan, M; Gourgon, R

    1994-06-01

    Left ventricular failure leads to circulatory failure which causes clinical symptoms and in which regional blood flow changes play an important role. An abnormality of systemic vasodilatation on exercise or on pharmacological intervention has been shown. This affects both the resistance and conductive vessels and is mainly functional, related to neurohormonal stimulation with a predominance of vasoconstrictive factors amongst which increased adrenergic tone probably plays an essential part. A modification of the endothelium-dependent response has recently been confirmed. The presence of structural vascular abnormalities (increase in parietal sodium and water concentrations, "remodelling" remains debatable in the human. These abnormalities have a common factor in their chronicity and take time to regress with medical treatment or after cardiac transplantation. Physical training seems to induce more marked and, above all, more rapid effects.

  13. The impact of socially responsible investment index constituent announcements on firm price: evidence from the JSE

    Directory of Open Access Journals (Sweden)

    Chimwemwe Chipeta

    2012-11-01

    Full Text Available This paper examines whether Socially Responsible Investment (SRI Index constituent announcements have any impact on the returns of firms listing on the JSE SRI Index. The event study methodology is utilised to estimate abnormal returns for the firms included in the Index. The results indicate insignificant average abnormal returns (AARs for the years 2004, 2006, 2007, 2008 and 2009, suggesting no significant shareholder gains over the entire event window. However, the year 2005 is associated with positive and significant abnormal returns. Post announcement cumulative average abnormal returns (CAARs are positive for the years 2005 and 2007. However, the year 2008 exhibited extreme swings in CAARs with a general declining trend in the latter part of the event window. These swings are attributed to the global financial crisis of 2008. Furthermore, the cumulative returns for the total sample show no clear outperformance of the SRI over the JSE All Share Index.

  14. Abnormal vibration induced illusion of movement in essential tremor: evidence for abnormal muscle spindle afferent function

    OpenAIRE

    Frima, N; Grunewald, R

    2005-01-01

    Objectives: Vibration induced illusion of movement (VIIM) is abnormal in patients with idiopathic focal dystonia, an abnormality which corrects with fatigue of the vibrated muscle. Since dystonia and essential tremor sometimes coexist in families, we investigated the perception of VIIM and the effect of fatigue on VIIM in patients with essential tremor.

  15. Nonpathologizing trauma interventions in abnormal psychology courses.

    Science.gov (United States)

    Hoover, Stephanie M; Luchner, Andrew F; Pickett, Rachel F

    2016-01-01

    Because abnormal psychology courses presuppose a focus on pathological human functioning, nonpathologizing interventions within these classes are particularly powerful and can reach survivors, bystanders, and perpetrators. Interventions are needed to improve the social response to trauma on college campuses. By applying psychodynamic and feminist multicultural theory, instructors can deliver nonpathologizing interventions about trauma and trauma response within these classes. We recommend class-based interventions with the following aims: (a) intentionally using nonpathologizing language, (b) normalizing trauma responses, (c) subjectively defining trauma, (d) challenging secondary victimization, and (e) questioning the delineation of abnormal and normal. The recommendations promote implications for instructor self-reflection, therapy interventions, and future research.

  16. Temporomandibular joint abnormalities in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Larheim, T.A.; Tveito, L.; Dale, K.; Ruud, A.F.

    1981-01-01

    Transantral (infraorbital, transmaxillary) examination of the temporomandibular joint was compared with conventional transcranial examination and lateral tomography of patients with rheumatoid arthritis aged 23 to 83. Abnormalities were most frequently found at tomography, and equally frequent at transantral and transcranial examinations. The various examinations appeared to be rather supplementary. Bone erosion was frequently observed at transantral examination, which appeared to be the preferable radiographic method for detecting arthritis of this joint. Combined with transcranial examination, the method is recommended for the evaluation of temporomandibular joint abnormalities in rheumatoid arthritis if tomographic equipment is not available. (Auth.)

  17. Temporal abnormalities in children with developmental dyscalculia.

    Science.gov (United States)

    Vicario, Carmelo Mario; Rappo, Gaetano; Pepi, Annamaria; Pavan, Andrea; Martino, Davide

    2012-01-01

    Recent imaging studies have associated Developmental dyscalculia (DD) to structural and functional alterations corresponding Parietal and the Prefrontal cortex (PFC). Since these areas were shown also to be involved in timing abilities, we hypothesized that time processing is abnormal in DD. We compared time processing abilities between 10 children with pure DD (8 years old) and 11 age-matched healthy children. Results show that the DD group underestimated duration of a sub-second scale when asked to perform a time comparison task. The timing abnormality observed in our DD participants is consistent with evidence of a shared fronto-parietal neural network for representing time and quantity.

  18. Browse Title Index

    African Journals Online (AJOL)

    OLD WOMAN: A CASE REPORT AND REVIEW OF LITERATURE, Abstract PDF. SS Danbauchi, MA Alhassan, IA Oyati, GC Onyemelukwe. Vol 4, No 4 (2005), Attitude of Nigerian women to abnormal menstrual bleeding from ...

  19. Analysis in indexing

    DEFF Research Database (Denmark)

    Mai, Jens Erik

    2005-01-01

    The paper discusses the notion of steps in indexing and reveals that the document-centered approach to indexing is prevalent and argues that the document-centered approach is problematic because it blocks out context-dependent factors in the indexing process. A domain-centered approach to indexing...... is presented as an alternative and the paper discusses how this approach includes a broader range of analyses and how it requires a new set of actions from using this approach; analysis of the domain, users and indexers. The paper concludes that the two-step procedure to indexing is insufficient to explain...

  20. Supersymmetry and index theory

    International Nuclear Information System (INIS)

    Alvarez-Gaume, L.

    1985-01-01

    The author presents information mainly concerned with the fact that many of the ingredients and results in index theory have very simple analogs in supersymmetric quantum mechanical systems so that using elementary quantum mechanics one can obtain new proofs of the Atiyah-Singer index theorem and related results. Simple ideas on index theorems and characteristic classes are reviewed; simple results on fermion functional integrals are outlined; supersymmetric quantum mechanical systems which appear naturally in dealing with index problems are analyzed; proof of the classical index theorem is presented; the character valued index theorem is derived; and applications of the methods developed here for the computation of anomalies are presented

  1. Climate index for Belgium - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Belgium. (J.S.)

  2. Climate index for Spain - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Spain. (J.S.)

  3. Climate index for France - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of France. (J.S.)

  4. Climate index for Switzerland - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Switzerland. (J.S.)

  5. Climate index for Portugal - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Portugal. (J.S.)

  6. Climate index for Germany - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Germany. (J.S.)

  7. Climate index for Italy - Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of average, minimum and maximum weather indexes with the winter and summer regression equations for the different economical regions of Italy. (J.S.)

  8. Prospective, randomized comparison between pulsatile GnRH therapy and combined gonadotropin (FSH+LH) treatment for ovulation induction in women with hypothalamic amenorrhea and underlying polycystic ovary syndrome.

    Science.gov (United States)

    Dubourdieu, Sophie; Fréour, Thomas; Dessolle, Lionel; Barrière, Paul

    2013-05-01

    To compare the efficacy of pulsatile GnRH therapy versus combined gonadotropins for ovulation induction in women with both hypothalamic amenorrhoea and polycystic ovarian syndrome (HA/PCOS) according to their current hypothalamic status. This single-centre, prospective, randomized study was conducted in the Nantes University Hospital, France. Thirty consecutive patients were treated for ovulation induction with either pulsatile GnRH therapy or combined gonadotropins (rFSH+rLH). Frequency of adequate ovarian response (mono- or bi-follicular) and clinical pregnancy rate were then compared between both groups. Ovarian response was similar in both groups with comparable frequency of adequate ovarian response (73% vs 60%), but the clinical pregnancy rate was significantly higher in the pulsatile GnRH therapy group than in the combined gonadotropin group (46% vs 0%). HA/PCOS is a specific subgroup of infertile women. Pulsatile GnRH therapy is an effective and safe method of ovulation induction that can be used successfully in these patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Western Alaska ESI: INDEX (Index Polygons)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains vector polygons representing the boundaries of all the hardcopy cartographic products produced as part of the Environmental Sensitivity Index...

  10. IndexCat

    Data.gov (United States)

    U.S. Department of Health & Human Services — IndexCat provides access to the digitized version of the printed Index-Catalogue of the Library of the Surgeon General's Office; eTK for medieval Latin texts; and...

  11. Body Mass Index Table

    Science.gov (United States)

    ... Families ( We Can! ) Health Professional Resources Body Mass Index Table 1 for BMI greater than 35, go ... Health Information Email Alerts Jobs and Careers Site Index About NHLBI National Institute of Health Department of ...

  12. Human Use Index

    Data.gov (United States)

    U.S. Environmental Protection Agency — Human land uses may have major impacts on ecosystems, affecting biodiversity, habitat, air and water quality. The human use index (also known as U-index) is the...

  13. Master Veteran Index (MVI)

    Data.gov (United States)

    Department of Veterans Affairs — As of June 28, 2010, the Master Veteran Index (MVI) database based on the enhanced Master Patient Index (MPI) is the authoritative identity service within the VA,...

  14. Human Use Index (Future)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Human land uses may have major impacts on ecosystems, affecting biodiversity, habitat, air and water quality. The human use index (also known as U-index) is the...

  15. Ophthalmologic abnormalities among deaf students in Kaduna ...

    African Journals Online (AJOL)

    Background: The association between deafness and ocular problems is well established; however the nature and prevalence of these problems are diverse across the globe. Objective: The aim of this study is to determine the nature and prevalence of ophthalmologic abnormalities in deaf students and offer treatment to ...

  16. Developmental abnormalities of mid and hindbrain

    African Journals Online (AJOL)

    1Pediatric Neurology Department, Cairo University, 2Clinical Genetics ... Research Centre,3Human Cytogenetics Department, Human Genetics and. Genome ..... cVH. 2/23 cri du chat. 1/23 del. 18q21.1- qter. 1/23. Breathing abnormalities. 3. 13. 3. -. 1. -. -. -. -. Feeding problems. 8. 34.8. -. 5. 2. -. -. 1. -. Autistic behavior. 3. 13.

  17. Prevelence and Pattern of Electrocardiographic Abnormalities Seen ...

    African Journals Online (AJOL)

    Objective: There is paucity of published data on the prevalence and pattern of electrocardiographic abnormalities (ECGA) seen in adult Nigerians referred for this investigation. This study determined the prevalence and pattern of some ECGA in Nigerian adults. Methods: This is a hospital based audit to determine the ...

  18. Relationship among sera lipoprotein abnormalities in healthy ...

    African Journals Online (AJOL)

    Jane

    2011-08-29

    Aug 29, 2011 ... HOMA-IR (P = 0.03) in the case group as compared to the control group. We conclude that a family history of diabetic parents can lead to lipid parameters abnormalities and CVD risk factor via aggregation of inherited defected genes. Key words: Diabetes, oxidized-low density lipoprotein (LDL), Apo B100, ...

  19. immunological arthritis Prevalence of biochemical and abnormalities ...

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... Tile prevalence of biochemical and immunological abnormali- ties was studied in a group of 256 patients with rheumatoid arthritis (104 coloureds, 100 whites and 52 blacks). The most common biochemical abnormalities detected were a reduction in the serum creatinine value (43,4%), raised globulins (39 ...

  20. Prevalence Of Dental Abnormalities Among Handicapped Children ...

    African Journals Online (AJOL)

    Over 34% of them had various dental abnormalities, the most commonly encountered being enamel hypoplasia which constituted 12.3%, and more than half of which was chronologic (58.9%). This was predominant among the mentally handicapped (13.5%) and the blind (12.5%). Tetracyline staining was also a common ...

  1. Dynamic Abnormal Grain Growth in Refractory Metals

    Science.gov (United States)

    Noell, Philip J.; Taleff, Eric M.

    2015-11-01

    High-temperature plastic deformation of the body-centered cubic (BCC) refractory metals Mo and Ta can initiate and propagate abnormal grains at significantly lower temperatures and faster rates than is possible by static annealing alone. This discovery reveals a new and potentially important aspect of abnormal grain growth (AGG) phenomena. The process of AGG during plastic deformation at elevated temperatures, termed dynamic abnormal grain growth (DAGG), was observed at homologous temperatures between 0.52 and 0.72 in both Mo and Ta sheet materials; these temperatures are much lower than those for previous observations of AGG in these materials during static annealing. DAGG was used to repeatedly grow single crystals several centimeters in length. Investigations to date have produced a basic understanding of the conditions that lead to DAGG and how DAGG is affected by microstructure in BCC refractory metals. The current state of understanding for DAGG is reviewed in this paper. Attention is given to the roles of temperature, plastic strain, boundary mobility and preexisting microstructure. DAGG is considered for its potential useful applications in solid-state crystal growth and its possibly detrimental role in creating undesired abnormal grains during thermomechanical processing.

  2. Somatic chromosomal abnormalities in couples undergoing infertility ...

    Indian Academy of Sciences (India)

    1999). Oligozoospermia is .... age of abnormal metaphases needed to distinguish between low level and true mosaicism. This borderline ... Moore A. K., Lynch K., Arny M. J. and Grow D. R. 2008 Turner mosaicism (45,X/46,XX) diagnosed in a ...

  3. Heat stress protection in abnormally hot environments.

    CSIR Research Space (South Africa)

    Schutte, PC

    1994-11-01

    Full Text Available The present report presents the findings of SIMRAC project GAP 045 entitled ‘Heat stress protection in abnormally hot environments’. It is intended as a reference to develop guidelines which, in turn would assist mine management in establishing safe...

  4. The prevalence of electroencephalographic abnormalities and ...

    African Journals Online (AJOL)

    Adele

    2004-05-20

    May 20, 2004 ... South African studies. There is little South African data examining either prevalence or usefulness of EEG abnormalities among adult psychiatric patients. Some work has been done in adolescents. Szabo1 reviewed all admissions to the adolescent inpatient unit at Tara. Hospital between 1990 and 1995.

  5. Lentiginosis, Deafness and Cardiac Abnormalities | Cronje | South ...

    African Journals Online (AJOL)

    Three members of a family with features of the 'leopard' syndrome are described. The important findings were generalized lentigo, deafness, and cardiac and electrocardiographic abnormalities. Progressive obstructive cardiomyopathy and arrhythmias are features of the condition which may be present, and are potentially ...

  6. Craniofacial abnormalities among patients with Edwards Syndrome

    Directory of Open Access Journals (Sweden)

    Rafael Fabiano M. Rosa

    2013-09-01

    Full Text Available OBJECTIVE To determine the frequency and types of craniofacial abnormalities observed in patients with trisomy 18 or Edwards syndrome (ES. METHODS This descriptive and retrospective study of a case series included all patients diagnosed with ES in a Clinical Genetics Service of a reference hospital in Southern Brazil from 1975 to 2008. The results of the karyotypic analysis, along with clinical data, were collected from medical records. RESULTS: The sample consisted of 50 patients, of which 66% were female. The median age at first evaluation was 14 days. Regarding the karyotypes, full trisomy of chromosome 18 was the main alteration (90%. Mosaicism was observed in 10%. The main craniofacial abnormalities were: microretrognathia (76%, abnormalities of the ear helix/dysplastic ears (70%, prominent occiput (52%, posteriorly rotated (46% and low set ears (44%, and short palpebral fissures/blepharophimosis (46%. Other uncommon - but relevant - abnormalities included: microtia (18%, orofacial clefts (12%, preauricular tags (10%, facial palsy (4%, encephalocele (4%, absence of external auditory canal (2% and asymmetric face (2%. One patient had an initial suspicion of oculo-auriculo-vertebral spectrum (OAVS or Goldenhar syndrome. CONCLUSIONS: Despite the literature description of a characteristic clinical presentation for ES, craniofacial alterations may be variable among these patients. The OAVS findings in this sample are noteworthy. The association of ES with OAVS has been reported once in the literature.

  7. Somatic chromosomal abnormalities in couples undergoing infertility ...

    Indian Academy of Sciences (India)

    1996; Johnson 1998). Consid- ering pooled data obtained from more than 9000 azoosper- mic and oligozoospermic men, a 5.8% incidence of chromo- somal abnormalities has been found. Of these, 4.2% affect the gonosomes and 1.5% the autosomes, respectively (John- son 1998). In detail, sex chromosome anomalies ...

  8. Fetal chromosome abnormalities and congenital malformations: an ...

    African Journals Online (AJOL)

    Objective: Our objective were to determine and evaluate the role of genetic counseling and amniocentesis in early detection of chromosomal abnormalities or congenital malformations among women at risk. Patients and Methods: The study was performed on 784 pregnant women. Results: The cause for seeking genetic ...

  9. Structural and molecular hair abnormalities in trichothiodystrophy.

    Science.gov (United States)

    Liang, Christine; Morris, Andrea; Schlücker, Sebastian; Imoto, Kyoko; Price, Vera H; Menefee, Emory; Wincovitch, Stephen M; Levin, Ira W; Tamura, Deborah; Strehle, Katrin R; Kraemer, Kenneth H; DiGiovanna, John J

    2006-10-01

    We examined hair from 15 patients with trichothiodystrophy (TTD), a rare inherited disorder with brittle, cystine-deficient hair. They had a wide variety of phenotypes, from brittle hair only to severe intellectual impairment and developmental delay. Polarizing light microscopic examination showed alternating light and dark (tiger tail) bands under polarizing microscopy. Confocal microscopy captured structural features of breaks in intact TTD hairs. The autofluorescent appearance was regular and smooth in normal donors and markedly irregular in sections of TTD hairs possibly reflecting abnormalities in melanin distribution. Scanning electron microscopy revealed numerous surface irregularities. All TTD hair samples had reduced sulfur content. We observed an inverse correlation (R(val)=0.9) between sulfur content and percent of hairs with shaft abnormalities (trichoschisis, trichorrhexis nodosa, or ribbon/twist). There was no association between clinical disease severity and percent of abnormal hairs. Raman spectra of hairs from TTD patients and normal donors revealed a larger contribution of energetically less favored disulfide conformers in TTD hairs. Our data indicate that the brittleness of the TTD hair is dependent upon abnormalities at several levels of organization. These changes make TTD hairs excessively prone to breakage and weathering.

  10. Correcting abnormal speaking through communication partners ...

    African Journals Online (AJOL)

    The listed characteristics are called speech disorders. Abnormal speaking attracts some penalties to the speaker. The penalties are usually very disturbing to the speaker that undertaking some therapeutic measures becomes inevitable. Communication partners strategy is a speech correction approach which makes use of ...

  11. Teaching Abnormal Psychology in a Multimedia Classroom.

    Science.gov (United States)

    Brewster, JoAnne

    1996-01-01

    Examines the techniques used in teaching an abnormal psychology class in a multimedia environment with two computers and a variety of audiovisual equipment. Students respond anonymously to various questions via keypads mounted on their desks, then immediately view and discuss summaries of their responses. (MJP)

  12. Schizophrenogenic Parenting in Abnormal Psychology Textbooks.

    Science.gov (United States)

    Wahl, Otto F.

    1989-01-01

    Considers the treatment of family causation of schizophrenia in undergraduate abnormal psychology textbooks. Reviews texts published only after 1986. Points out a number of implications for psychologists which arise from the inclusion in these texts of the idea that parents cause schizophrenia, not the least of which is the potential for…

  13. Abnormal interhemispheric connectivity in male psychopathic offenders.

    Science.gov (United States)

    Hoppenbrouwers, Sylco S; De Jesus, Danilo R; Sun, Yinming; Stirpe, Tania; Hofman, Dennis; McMaster, Jeff; Hughes, Ginny; Daskalakis, Zafiris J; Schutter, Dennis J L G

    2014-01-01

    Psychopathic offenders inevitably violate interpersonal norms and frequently resort to aggressive and criminal behaviour. The affective and cognitive deficits underlying these behaviours have been linked to abnormalities in functional interhemispheric connectivity. However, direct neurophysiological evidence for dysfunctional connectivity in psychopathic offenders is lacking. We used transcranial magnetic stimulation combined with electroencephalography to examine interhemispheric connectivity in the dorsolateral and motor cortex in a sample of psychopathic offenders and healthy controls. We also measured intracortical inhibition and facilitation over the left and right motor cortex to investigate the effects of local cortical processes on interhemispheric connectivity. We enrolled 17 psychopathic offenders and 14 controls in our study. Global abnormalities in right to left functional connectivity were observed in psychopathic offenders compared with controls. Furthermore, in contrast to controls, psychopathic offenders showed increased intracortical inhibition in the right, but not the left, hemisphere. The relatively small sample size limited the sensitivity to show that the abnormalities in interhemispheric connectivity were specifically related to the dorsolateral prefrontal cortex in psychopathic offenders. To our knowledge, this study provides the first neurophysiological evidence for abnormal interhemispheric connectivity in psychopathic offenders and may further our understanding of the disruptive antisocial behaviour of these offenders.

  14. Psychology Faculty Perceptions of Abnormal Psychology Textbooks

    Science.gov (United States)

    Rapport, Zachary

    2011-01-01

    The problem. The purpose of the current study was to investigate the perceptions and opinions of psychology professors regarding the accuracy and inclusiveness of abnormal psychology textbooks. It sought answers from psychology professors to the following questions: (1) What are the expectations of the psychology faculty at a private university of…

  15. Plant abnormality monitoring method and device therefor

    International Nuclear Information System (INIS)

    Isobe, Yusuke; Uchida, Shunsuke; Fujimori, Haruo.

    1997-01-01

    The present invention provides a method and a device capable of detecting abnormal symptoms of equipments having failed portions and portions to be repaired and requiring concentrated monitoring in a plant during operation, for example, nuclear power plants, in an early stage without losing reliability. Namely, the abnormality of the plant is judged based on the comparison of plant operation parameters and their allowable values in the method of monitoring plant abnormality. In this case, the allowable values of the plant operation parameters allowed to be changed based on the information on the state of equipments which shows the state of constitutional equipments of the plant. In addition, when a measured plant operation parameter exceeds the allowable value of each of the previously set plant operation parameters, allowable values of other plant operation parameters having relation with the plant operation parameters can be changed. According to the present invention, since the allowable range of the plant operation parameters for the equipments to be repaired and failed equipments can be made narrower than that of ordinary equipments, abnormal symptoms can be detected on the normal side in an early stage. (I.S.)

  16. ORIGINAL ARTICLE EEG changes and neuroimaging abnormalities ...

    African Journals Online (AJOL)

    salah

    Background:Autism is currently viewed as a genetically determined neurode- velopmental disorder although its definite underlying etiology remains to be established. Aim of the Study: Our purpose was to assess autism related morphological neuroimaging changes of the brain and EEG abnormalities in correlation to the.

  17. Craniocervical junction abnormalities with atlantoaxial subluxation ...

    African Journals Online (AJOL)

    Craniocervical junction abnormalities with atlantoaxial subluxation caused by ventral subluxation of C2 were diagnosed in a 6-month-old female Pomeranian with tetraplegia as a clinical sign. Lateral survey radiography of the neck with flexion revealed atlantoaxial subluxation with ventral subluxation of C2. Computed ...

  18. Recurrent chromosome 6 abnormalities in malignant mesothelioma.

    Science.gov (United States)

    Ribotta, M; Roseo, F; Salvio, M; Castagneto, B; Carbone, M; Procopio, A; Giordano, A; Mutti, L

    1998-04-01

    The long latency period between asbestos exposure and the onset of malignant mesothelioma (MM) suggests that a multistep tumorigenesis process occurs whilst the capability of asbestos fibres to interfere directly with chromosomes focuses on the critical role of the chromosomal abnormalities in this neoplasm. The aim of our study was to identify any recurrent chromosomal changes in ten primary MM cell cultures derived from pleural effusions of patients with MM from the same geographic area and environmental and/or occupational exposure to asbestos fibers. Cytogenetic analysis was performed in accordance with International System for Human Cytogenetic Nomenclature. Our results confirmed a great number of cytogenetic abnormalities in MM cells. Recurrent loss of the long arms of chromosome 6 (6q-) was the most frequent abnormality detected (four epithelial and two mixed subtypes) while, on the whole, abnormalities of chromosome 6 were found in nine out of ten cases whereas chromosome 6 was normal only in the case with fibromatous subtype. Monosomy 13 and 17 was found in five cases, monosomy 14 in four cases and 22 in three cases. Since deletion of 6q- was detected even in relatively undisturbed karyotype, we hypothesize a multistep carcinogenic process in which deletion of 6q- is an early event in the development and progression of malignant mesothelioma.

  19. Ophthalmological abnormalities in wild European hedgehogs ...

    African Journals Online (AJOL)

    In this study we aimed to examine wild European hedgehogs (Erinaceus europaeus) in rescue centres and to determine ocular abnormalities in this animal population. Three hundred animals varying in age from 2 months to 5 years were examined, 147 being male and 153 female. All animals were evaluated with direct ...

  20. Gastric emptying abnormal in duodenal ulcer

    International Nuclear Information System (INIS)

    Holt, S.; Heading, R.C.; Taylor, T.V.; Forrest, J.A.; Tothill, P.

    1986-01-01

    To investigate the possibility that an abnormality of gastric emptying exists in duodenal ulcer and to determine if such an abnormality persists after ulcer healing, scintigraphic gastric emptying measurements were undertaken in 16 duodenal ulcer patients before, during, and after therapy with cimetidine; in 12 patients with pernicious anemia, and in 12 control subjects. No difference was detected in the rate or pattern of gastric emptying in duodenal ulcer patients before and after ulcer healing with cimetidine compared with controls, but emptying of the solid component of the test meal was more rapid during treatment with the drug. Comparison of emptying patterns obtained in duodenal ulcer subjects during and after cimetidine treatment with those obtained in pernicious anemia patients and controls revealed a similar relationship that was characterized by a tendency for reduction in the normal differentiation between the emptying of solid and liquid from the stomach. The similarity in emptying patterns in these groups of subjects suggests that gastric emptying of solids may be influenced by changes in the volume of gastric secretion. The failure to detect an abnormality of gastric emptying in duodenal ulcer subjects before and after ulcer healing calls into question the widespread belief that abnormally rapid gastric emptying is a feature with pathogenetic significance in duodenal ulcer disease

  1. Glucose abnormalities in Asian patients with chronic hepatitis C

    Directory of Open Access Journals (Sweden)

    Bo Q

    2015-11-01

    Full Text Available Qingyan Bo,1 Roberto Orsenigo,2 Junyi Wang,1 Louis Griffel,3 Clifford Brass3 1Beijing Novartis Pharma Co. Ltd., Shanghai, People’s Republic of China; 2Novartis Pharma AG, Basel, Switzerland; 3Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA Abstract: Many studies have demonstrated a potential association between type 2 diabetes (T2D and hepatitis C virus infection in Western countries, while similar evidence is limited in Asia. We compared the prevalence of glucose abnormalities (impaired fasting glucose [IFG] and T2D and their risk factors between Asian and non-Asian chronic hepatitis C (CHC patients, and evaluated whether glucose abnormalities impacted the viral responses to peginterferon plus ribavirin treatment (current standard of care in most Asian countries. This study retrospectively analyzed data of 1,887 CHC patients from three Phase II/III studies with alisporivir (DEB025 as treatment for CHC. The chi-square test was used to compare the prevalence of IFG/T2D between Asian and non-Asian CHC patients, and logistic regression was used to adjust for sex, age, and cirrhosis status. Risk factors for IFG/T2D were evaluated using univariate and multivariate analysis. Our results indicated that the prevalence of IFG/T2D was high in both Asian and non-Asian CHC patients (23.0% vs 20.9%, and no significant difference was found between these two populations (adjusted odds ratio: 1.3, 95% confidence interval: 0.97, 1.7; P=0.08. Age, sex, and cirrhosis status were risk factors for IFG/T2D in both populations, while body mass index was positively associated with IFG/T2D in non-Asian but not in Asian participants. No significant differences in sustained virological response rates were seen between patients with normal fasting glucose and patients with IFG/T2D for both populations. These results demonstrate that the prevalence of glucose abnormalities in Asian CHC patients was similar to that in non-Asians, and glucose abnormalities had

  2. Abnormal Selective Attention Normalizes P3 Amplitudes in PDD

    Science.gov (United States)

    Hoeksma, Marco R.; Kemner, Chantal; Kenemans, J. Leon; van Engeland, Herman

    2006-01-01

    This paper studied whether abnormal P3 amplitudes in PDD are a corollary of abnormalities in ERP components related to selective attention in visual and auditory tasks. Furthermore, this study sought to clarify possible age differences in such abnormalities. Children with PDD showed smaller P3 amplitudes than controls, but no abnormalities in…

  3. Indexing Executive Compensation Contracts

    NARCIS (Netherlands)

    I. Dittmann (Ingolf); E.G. Maug (Ernst); O.G. Spalt (Oliver)

    2013-01-01

    textabstractWe analyze the efficiency of indexing executive pay by calibrating the standard model of executive compensation to a large sample of US CEOs. The benefits from linking the strike price of stock options to an index are small and fully indexing all options would increase compensation costs

  4. The Europe 2020 Index

    Science.gov (United States)

    Pasimeni, Paolo

    2013-01-01

    This paper presents a new index to quantify, measure and monitor the progress towards the objectives of the Europe 2020 strategy. This index is based on a set of relevant, accepted, credible, easy to monitor and robust indicators presented by the European Commission at the time the strategy was launched. The internal analysis of the index shows…

  5. Corpus callosum abnormalities: neuroradiological and clinical correlations.

    Science.gov (United States)

    Al-Hashim, Aqeela H; Blaser, Susan; Raybaud, Charles; MacGregor, Daune

    2016-05-01

    To study neuroradiological features in pediatric patients with corpus callosum abnormalities, using new functional subtyping for the corpus callosum, and to correlate the features with the clinical presentation. We performed a retrospective review of 125 patients with radiologically identified abnormalities of the corpus callosum seen between 1999 and 2012. The study reviewed clinical features, genetic etiology, and chromosomal microarray (CMA) results. We used a new functional classification for callosal abnormalities based on embryological and anatomical correlations with four classes: complete agenesis, anterior agenesis (rostrum, genu, body), posterior agenesis (isthmus, splenium), and complete hypoplasia (thinning). We also studied the presence of extracallosal abnormalities. The new functional callosal subtyping did not reveal significant differences between the various subtypes in association with neurological outcome; however, the presence of cardiac disease was found more frequently in the group with complete agenesis. Thirty-seven per cent (46/125) had identifiable causes: of these, 48% (22/46) had a monogenic disorder, 30% (14/46) had a pathogenic chromosomal copy-number variant detected by CMA or karyotype, and 22% (10/46) had a recognizable clinical syndrome for which no confirmatory genetic test was available (namely Aicardi syndrome/septo-optic dysplasia and Goldenhar syndrome). The diagnostic yield for a significant CMA change was 19%. The presence of Probst bundles was found to be associated with a better neurodevelopmental outcome. The functional classification system alone 'without clinical data' cannot predict the functional outcome. The presence of extracallosal brain abnormalities and an underlying genetic diagnosis predicted a worse neurodevelopmental outcome. This study highlights the importance of CMA testing and cardiac evaluation as part of a routine screen. © 2015 Mac Keith Press.

  6. Hemostatic Abnormalities in Multiple Myeloma Patients

    Science.gov (United States)

    Gogia, Aarti; Sikka, Meera; Sharma, Satender; Rusia, Usha

    2018-01-27

    Background: Multiple myeloma (MM) is a neoplastic plasma cell disorder characterized by clonal proliferation of plasma cells in the bone marrow. Diverse hemostatic abnormalities have been reported in patients with myeloma which predispose to bleeding and also thrombosis. Methods: Complete blood count, biochemical parameters and parameters of hemostasis i.e. platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), factor VIII assay results, plasma fibrinogen, D-dimer and lupus anticoagulant, were assessed in 29 MM patients and 30 age matched controls. Results: The most frequent abnormal screening parameter was APTT. Of the six indicative of a bleeding tendency i.e. thrombocytopenia, prolonged PT, APTT, TT, reduced plasma fibrinogen and factor VIII, at least one was abnormal in 8 (27.6%) patients. Of the four prothrombotic markers, lupus anticoagulant, D-dimer, elevated factor VIII and plasma fibrinogen, one or more marker was present in 24 (82.7%). D-dimer was the most common prothrombotic marker, being elevated in 22 (75.9%) patients. One or more laboratory parameter of hemostasis was abnormal in all 29 (100%) patients. Though thrombotic complications are reported to be less frequent as compared to hemorrhagic manifestations, one or more marker of thrombosis was present in 24 (82.7%) patients. Conclusion: This study provided laboratory evidence of hemostatic dysfunction which may be associated with thrombotic or bleeding complications at diagnosis in all MM patients. Hence, screening for these abnormalities at the time of diagnosis should help improved prognosis in such cases. Creative Commons Attribution License

  7. Parenchymal abnormalities associated with developmental venous anomalies

    Energy Technology Data Exchange (ETDEWEB)

    San Millan Ruiz, Diego; Gailloud, Philippe [Johns Hopkins Hospital, Division of Interventional Neuroradiology, Baltimore, MD (United States); Delavelle, Jacqueline [Geneva University Hospital, Neuroradiology Section, Department of Radiology and Medical Informatics, Geneva (Switzerland); Yilmaz, Hasan; Ruefenacht, Daniel A. [Geneva University Hospital, Section of Interventional Neuroradiology, Department of Clinical Neurosciences, Geneva (Switzerland); Piovan, Enrico; Bertramello, Alberto; Pizzini, Francesca [Verona City Hospital, Service of Neuroradiology, Verona (Italy)

    2007-12-15

    To report a retrospective series of 84 cerebral developmental venous anomalies (DVAs), focusing on associated parenchymal abnormalities within the drainage territory of the DVA. DVAs were identified during routine diagnostic radiological work-up based on magnetic resonance imaging (MRI) (60 cases), computed tomography (CT) (62 cases) or both (36 cases). Regional parenchymal modifications within the drainage territory of the DVA, such as cortical or subcortical atrophy, white matter density or signal alterations, dystrophic calcifications, presence of haemorrhage or a cavernous-like vascular malformation (CVM), were noted. A stenosis of the collecting vein of the DVA was also sought for. Brain abnormalities within the drainage territory of a DVA were encountered in 65.4% of the cases. Locoregional brain atrophy occurred in 29.7% of the cases, followed by white matter lesions in 28.3% of MRI investigations and 19.3% of CT investigations, CVMs in 13.3% of MRI investigations and dystrophic calcification in 9.6% of CT investigations. An intracranial haemorrhage possibly related to a DVA occurred in 2.4% cases, and a stenosis on the collecting vein was documented in 13.1% of cases. Parenchymal abnormalities were identified for all DVA sizes. Brain parenchymal abnormalities were associated with DVAs in close to two thirds of the cases evaluated. These abnormalities are thought to occur secondarily, likely during post-natal life, as a result of chronic venous hypertension. Outflow obstruction, progressive thickening of the walls of the DVA and their morphological organization into a venous convergence zone are thought to contribute to the development of venous hypertension in DVA. (orig.)

  8. Regional indexes for France. Methodology

    International Nuclear Information System (INIS)

    2006-01-01

    According to the U.S. Department of Energy, an estimated 25% of the GNP is affected by weather-related events. The variations in temperature - even small ones - can also have long-lasting effects on the operational results of a company. Among other, the Energy supply sector is sensitive to weather risks: a milder or harsher than usual winter leads to a decrease or increase of energy consumption. The price of electricity on power trading facilities like Powernext is especially sensitive to odd changes in temperatures. Powernext and Meteo-France (the French meteorological agency) have joined expertise in order to promote the use of weather indices in term of decision making or underlying of hedging tools to energy actors, end users from any other sector of activity and specialists of the weather risk hedging. The Powernext Weather indices are made from information collected by Meteo-France's main observation network according to the norms of international meteorology, in areas carefully selected. The gross data are submitted to a thorough review allowing the correction of abnormalities and the reconstitution of missing data. Each index is fashioned to take into account the economic activity in the various regions of the country as represented by each region's population. This demographic information represents a fair approximation of the weight of the regional economic activity. This document presents the calculation methodology of regional weather indexes for France. Each regional index covers an homogenous area in terms of temperature represented by the biggest city. Five reference cities are used to represent the 22 economical regions of France (Paris Orly, Lyon, Marignane, Bordeaux and Strasbourg). (J.S.)

  9. Prevalence of abnormal patellofemoral congruence in elite American football players and association with quadriceps isokinetic testing.

    Science.gov (United States)

    Brown, Christopher A; Carragee, Cat; Sox-Harris, Alex; Merchant, Alan C; Mcadams, Timothy R

    2014-02-01

    Abnormal patellofemoral joint alignment has been discussed as a potential risk factor for patellofemoral disorders and can impact the longevity of any elite athlete's career. The prevalence of abnormal patellofemoral congruence in elite American football athletes is similar to the general population and does not have a relationship with quadriceps isokinetic testing. A total of 125 athletes (220 knees) from the 2011 National Football League (NFL) Combine database who had radiographic and isokinetic studies were reviewed. Congruence angles (CA) and lateral patellofemoral angles (LPA) were calculated on a Merchant radiographic view. Isokinetic testing was used to determine quadriceps-to-hamstring strength (Q/H) ratio and side-to-side deficits. The relationships between abnormal CA and LPA with Q/H ratios, side-to-side deficits, and body mass index (BMI) were examined in separate logistic regression models. A Chi-square test was used to examine the association between CA and player position. Of all, 26.8% of the knees (95% CI: 21.1-33.2%) had an abnormal CA. Knees with normal CA (n = 161) did not significantly differ from those with an abnormal CA (n  = 59) in Q/H ratios (mean: 0.699 vs. 0.728, p = 0.19) or side-to-side quadriceps deficits (mean: 4.0 vs. 1.24, p  = 0.45). For each point increase in BMI, the odds ratio (OR) of abnormal congruence increased by 11.4% (p = 0.002). Of all the knees, 4.1% (95% CI: 1.9-7.6%) had an abnormal LPA, and this was not associated with Q/H ratios (p  =  0.13). For each point increase in BMI, the odds of abnormal LPA increased by 16% (p  = 0.036). CA abnormality had much higher odds of having an abnormal LPA (OR: 5.96, p = 0.014). We found that abnormal patellofemoral radiographic alignment in elite American football players is relatively common and there was no association with isokinetic testing. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Pediatric Patients Discharged from the Emergency Department with Abnormal Vital Signs

    Directory of Open Access Journals (Sweden)

    Josephine Winter

    2017-07-01

    Full Text Available Introduction: Children often present to the emergency department (ED with minor conditions such as fever and have persistently abnormal vital signs. We hypothesized that a significant portion of children discharged from the ED would have abnormal vital signs and that those discharged with abnormal vital signs would experience very few adverse events. Methods: We performed a retrospective chart review encompassing a 44-month period of all pediatric patients (aged two months to 17 years who were discharged from the ED with an abnormal pulse rate, respiratory rate, temperature, or oxygen saturation. We used a local quality assurance database to identify pre-defined adverse events after discharge in this population. Our primary aim was to determine the proportion of children discharged with abnormal vital signs and the frequency and nature of adverse events. Additionally, we performed a sub-analysis comparing the rate of adverse events in children discharged with normal vs. abnormal vital signs, as well as a standardized review of the nature of each adverse event. Results: Of 33,185 children discharged during the study period, 5,540 (17% of these patients had at least one abnormal vital sign. There were 24/5,540 (0.43% adverse events in the children with at least one abnormal vital sign vs. 47/27,645 (0.17% adverse events in the children with normal vital signs [relative risk = 2.5 (95% confidence interval, 1.6 to 2.4].However, upon review of each adverse event we found only one case that was related to the index visit, was potentially preventable by a 23-hour hospital observation, and caused permanent disability. Conclusion: In our study population, 17% of the children were discharged with at least one abnormal vital sign, and there were very few adverse (0.43% events associated with this practice. Heart rate was the most common abnormal vital sign leading to an adverse event. Severe adverse events that were potentially related to the abnormal

  11. The umbilical coiling index, a review of the literature

    NARCIS (Netherlands)

    de Laat, Monique W. M.; Franx, Arie; van Alderen, Elise D.; Nikkels, Peter G. J.; Visser, Gerard H. A.

    2005-01-01

    Our aim was to review the literature on umbilical cord coiling. Relevant articles in English published between 1966 and 2003 were retrieved by a Medline search and cross-referencing. The normal umbilical cord coiling index (UCI) is 0.17 (+/- 0.009) spirals completed per cm. Abnormal cord coiling,

  12. Price Response to Factor Index Additions and Deletions

    NARCIS (Netherlands)

    J.J. Huij (Joop); G. Kyosev (Georgi)

    2016-01-01

    textabstractAbnormal price reaction around S&P 500 index changes has been considered as strong evidence that long term demand for stocks is downward sloping. This notion, however, has recently lost popularity due to the evidence that new additions are accompanied with a contemporaneous change in

  13. The Two Populations of Kisspeptin Neurons Are Involved in the Ram-Induced LH Pulsatile Secretion and LH Surge in Anestrous Ewes.

    Science.gov (United States)

    Fabre-Nys, Claude; Cognié, Juliette; Dufourny, Laurence; Ghenim, Meriem; Martinet, Stephanie; Lasserre, Olivier; Lomet, Didier; Millar, Robert P; Ohkura, Satoshi; Suetomi, Yuta

    2017-11-01

    Exposure to a ram during spring stimulates luteinizing hormone (LH) secretion and can induce ovulation in sexually quiescent ewes ("ram effect"). Kisspeptin (Kiss) present in the arcuate nucleus (ARC) and the preoptic area (POA) is a potent stimulators of LH secretion. Our aim was to investigate whether Kiss neurons mediate the increase in LH secretion during the ram effect. With double immunofluorescent detection, we identified Kiss neurons (Kiss IR) activated (Fos IR) by exposure to a ram for 2 hours (M2) or 12 hours (M12) or to ewes for 2 hours (C). The density of cells Kiss + Fos IR and the proportion of Kiss IR cells that were also Fos IR cells were higher in M2 and M12 than in C in ARC (P populations of Kiss neurons are involved in the ram-induced pulsatile LH secretion and in the LH surge. Copyright © 2017 Endocrine Society.

  14. Associations among ADHD, Abnormal Eating and Overweight in a non-clinical sample of Asian children

    OpenAIRE

    Tong, Lian; Shi, Huijing; Li, Xiaoru

    2017-01-01

    Attention-deficit/hyperactivity disorder (ADHD) has been found to be comorbid with obesity in adults, but the association in children is uncertain. Because the underlying mechanism of comorbidity in children has not been researched sufficiently, this study aims to explore the associations among ADHD, abnormal eating, and body mass index (BMI), as well as the mediating effect of depression in children. We conducted a cross-sectional study of 785 primary students in China. The parent-report ver...

  15. DNA synthesis, cell proliferation index in normal and abnormal gallbladder epithelium.

    Science.gov (United States)

    Lamote, J; Willems, G

    1997-09-15

    The observation of mitotic figures in the epithelium of the normal gallbladder is exceptional because cell renewal is occurring at a very slow rate. It is only after using 3H-thymidine and autoradiography to observe the cells in DNA synthesis that evidence of a significant epithelial cell replication has been provided. Because numerous mitotic figures and increased 3H-thymidine uptake have been observed after intraluminal introduction of foreign bodies or after ligation of the common bile duct in animals, mechanical distension has been supposed to represent an important trigger factor of cell proliferation in this hollow organ. An increased epithelial cell renewal was also observed in human gallbladders of patients with a complete obstruction of the common bile duct causing the distension. However, the absence of correlation between the degree of gallbladder distension and the proliferative response was suggesting that factors other than distension could be involved. In studies on experimental lithiasis cell proliferation appeared to be enhanced in the gallbladder epithelium of mice fed on a cholesterol-cholic acid-rich lithogenic diet. The fact that the increase in proliferative activity was preceding the formation of gallstones was another indication that factors other than mechanical stimulation by stretching or by the stones may stimulate cell renewal in this organ. Factors in the bile of animals receiving a lithogenic diet could be involved which might cause cellular death and, hence, a regenerative reaction. Direct mitogenic effect of an unknown factor in the bile of these animals is an alternative possibility. On the other hand the stimulating effect of postprandial hormones on gallbladder cell renewal suggested by the observation of a DNA synthesis peak after feeding has been established. Synthetic cholecystokinin analogues have been shown to increase the proliferative activity and to induce epithelial hyperplasia in this organ. In one recent study using fundusectomy to increase the serum gastrin levels, a significant proliferative stimulation in the gallbladder was also observed. In human gallbladder mitotic activity in gallbladders with gallstones in much higher than in the controls. No correlation between stone number, weight or volume and the proliferative activity was put in evidence, whereas cell renewal appeared to be more influenced by the composition of the stones than by their physical presence. Epithelial DNA synthesis activity was, namely, much higher in gallbladders with cholesterol stones than in those with pigment stones. Whether increased cell turnover and, hence, cellular shedding into the lumen could represent a nucleating factor for cholesterol stones is an attractive working hypothesis. Considering the very high frequency of gallstones in man and also the frequent association of gallbladder cancer and lithiasis, further studies on mitotic activity in this organ are required. In conclusion, data from animal experiments and in vitro studies on human gallbladders indicate that gallbladder epithelial cell proliferation may be influenced by several mechanical, chemical and hormonal factors. The list of these factors is still incomplete while their possible role in gallbladder disease is a fascinating exploration field for future research.

  16. Antineoplastic chemotherapy and congenital tooth abnormalities in children and adolescents

    Directory of Open Access Journals (Sweden)

    Ewa Krasuska-Sławińska

    2016-12-01

    Full Text Available Aim of the study : Chemotherapeutic treatment in children and adolescents carries a risk of congenital tooth disorders and dentinoma. Study objective is to assess the correlation between tooth abnormalities, early complications of multidrug chemotherapy, and chemotherapeutics used in different antineoplastic therapies in children and adolescents. Material and methods : Enamel defects (developmental defects of enamel index – DDE index and defects in tooth number, size, and structure were assessed clinically and radiologically in 60 patients who underwent chemotherapy on average 4.9 ±3.4 years earlier (PCH, and 60 generally healthy subjects (control group – CG, aged 6–18 years. Höltta’s defect index (DeI was calculated. Medical files provided information on neoplasm type, age at treatment start and chemotherapy duration, chemotherapeutic type and dose, vomiting, and mucositis (CTCAE v4.0. Statistical significance of differences between groups was assessed with the Mann-Whitney U test and the correlation between dental defects and chemotherapy with Spearman’s rank correlation coefficient (significance p ≤ 0.05. Results: Enamel defects, tooth agenesis, microdontia, root resorption, taurodontism, and dentinoma occurred statistically significantly more often in the PCH group. A correlation was established between vincristine use and dose and all types of dental defects; cyclophosphamide, doxorubicin, and isophosphamide and hypodontia; microdontia, root resorption, and enamel defects; etoposide and cisplatin and microdontia, root resorption, and enamel defects; methotrexate root resorption and enamel defects; carboplatin and dentinoma and enamel defects. Mucositis and vomiting promoted root resorption, microdontia, and enamel defects. Conclusions : Dental defects are related to both the use of respective chemotherapeutics, especially vincristine, cyclophosphamide, doxorubicin, and isophosphamide, and to early complications in multidrug

  17. Increased Risk of Advanced Colorectal Neoplasia Among Korean Men With Metabolic Abnormality and Obesity.

    Science.gov (United States)

    Kim, Ji Yeon; Park, Dong Il; Yu, Junghee; Jung, Yoon Suk; Park, Jung Ho; Kim, Hong Joo; Cho, Yong Kyun; Sohn, Chong Il; Jeon, Woo Kyu; Kim, Byung Ik; Choi, Kyu Yong

    2016-09-01

    Obesity and metabolic abnormality are risk factors for colorectal cancer and adenoma. We evaluated the risk of advanced colorectal neoplasm (AN) according to metabolic status and obesity in Koreans. We performed a retrospective cross-sectional study of 70,428 individuals in Korea who underwent colonoscopy and whose metabolic state and body mass index were examined, from 2003 through 2012, at Kangbuk Samsung Hospital in Korea. We calculated odds ratios (ORs) for AN in people who were metabolically healthy but obese, people with metabolic abnormality who were not obese, and people with metabolic abnormality who were obese. The reference group was metabolically healthy nonobese peoples. AN was defined as adenoma ≥10 mm in diameter, adenoma with any component of villous histology, high-grade dysplasia, or invasive cancer. No increased risk of AN was observed in the metabolically healthy but obese (OR, 0.99; 95% confidence interval [CI], 0.67-1.46; P = .825) and metabolic abnormality who were not obese groups (OR, 1.01; 95% CI, 0.85-1.21; P = .765). In contrast, risk of AN was increased in the metabolic abnormality who were obese group (OR, 1.33; 95% CI, 1.12-1.58; P = .006). In men, risk of AN showed a greater increase in the metabolic abnormality who were obese group (OR, 1.48; 95% CI, 1.20-1.83; P = .001). This association was not observed in women (OR, 1.21; 95% CI, 0.84-1.75; P = .476). Men with 1 or more metabolic abnormality and obesity are at increased risk for AN. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  18. Migraine and structural abnormalities in the brain

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal Mohammad; Ashina, Messoud

    2014-01-01

    PURPOSE OF REVIEW: The aim is to provide an overview of recent studies of structural brain abnormalities in migraine and to discuss the potential clinical significance of their findings. RECENT FINDINGS: Brain structure continues to be a topic of extensive research in migraine. Despite advances...... in neuroimaging techniques, it is not yet clear if migraine is associated with grey matter changes. Recent large population-based studies sustain the notion of increased prevalence of white matter abnormalities in migraine, and possibly of silent infarct-like lesions. The clinical relevance of this association...... is not clear. Structural changes are not related to cognitive decline, but a link to an increased risk of stroke, especially in patients with aura, cannot be ruled out. SUMMARY: Migraine may be a risk factor for structural changes in the brain. It is not yet clear how factors such as migraine sub-type, attack...

  19. [Otoneurologic abnormalities in insulin-dependent diabetes].

    Science.gov (United States)

    Jáuregui-Renaud, K; Domínguez-Rubio, B; Ibarra-Olmos, A; González-Bárcena, D

    1998-01-01

    To assess the auditory and vestibular function in patients with diabetes. We studied and followed for three years, 10 patients (6 females) of 20.6 years of age (SD 5.5 years), with insulindependent diabetes mellitus of 9.5 years (SD 3.7 years). The patients were selected for having peripheral neuropathy without prolipherative retinopathy and otologic disease or individual factors which could cause neurootologic symptoms. Their glomerular filtration rate and renal plasma flow were 150 mL/min (SD 50) and 543 mL/min (SD 113). Initially all patients had normal audiologic responses, including auditory brainstem responses, but had abnormally and simetrically diminished horizontal vestibulo-ocular responses. A year later one patient had vertigo and asymmetric vestibulo-ocular responses. In the third year, another patient showed similar abnormalities and a third one showed sensorineural hearing loss. Our results suggest that patients with insulindependent diabetes mellitus may suffer neuro-otological deterioration.

  20. Chromosomal abnormalities in a psychiatric population

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, K.E.; Lubetsky, M.J.; Wenger, S.L.; Steele, M.W. [Univ. of Pittsburgh Medical Center, PA (United States)

    1995-02-27

    Over a 3.5 year period of time, 345 patients hospitalized for psychiatric problems were evaluated cytogenetically. The patient population included 76% males and 94% children with a mean age of 12 years. The criteria for testing was an undiagnosed etiology for mental retardation and/or autism. Cytogenetic studies identified 11, or 3%, with abnormal karyotypes, including 4 fragile X positive individuals (2 males, 2 females), and 8 with chromosomal aneuploidy, rearrangements, or deletions. While individuals with chromosomal abnormalities do not demonstrate specific behavioral, psychiatric, or developmental problems relative to other psychiatric patients, our results demonstrate the need for an increased awareness to order chromosomal analysis and fragile X testing in those individuals who have combinations of behavioral/psychiatric, learning, communication, or cognitive disturbance. 5 refs., 1 fig., 2 tabs.

  1. Cardiovascular Abnormalities in Cirrhosis: the Possible Mechanisms

    Directory of Open Access Journals (Sweden)

    Leila Moezi

    2007-12-01

    Full Text Available Cirrhosis is characterized by marked abnormalities in the cardiovascular system. A hyperdynamic splanchnic and systemic circulation is typical of cirrhotic patients and has been observed in all experimental forms of portal hypertension. The hyperdynamic circulation is most likely initiated by arterial vasodilatation, leading to central hypovolemia, sodium retention, and an increased intravascular volume. Despite the baseline increase in cardiac output, ventricular inotropic and chronotropic responses to stimuli are blunted, a condition known as cirrhotic cardiomyopathy. This review briefly examines the major mechanisms that may underlie these cardiovascular abnormalities, concentrating on nitric oxide, endocannabinoids, prostaglandins, carbon monoxide, endogenous opioids, and adrenergic receptor changes. Future work should address the complex interrelationships between these systems.

  2. Selective mutism and abnormal electroencephalography (EEG) tracings.

    Science.gov (United States)

    Politi, Keren; Kivity, Sara; Goldberg-Stern, Hadassa; Halevi, Ayelet; Shuper, Avinoam

    2011-11-01

    Epileptic discharges are not considered a part of the clinical picture of selective mutism, and electroencephalography is generally not recommended in its work-up. This report describes 6 children with selective mutism who were found to have a history of epilepsy and abnormal interictal or subclinical electroencephalography recordings. Two of them had benign epilepsy of childhood with centro-temporal spikes. The mutism was not related in time to the presence of active seizures. While seizures could be controlled in all children by medications, the mutism resolved only in 1. Although the discharges could be coincidental, they might represent a co-morbidity of selective mutism or even play a role in its pathogenesis. Selective mutism should be listed among the psychiatric disorders that may be associated with electroencephalographic abnormalities. It can probably be regarded as a symptom of a more complicated organic brain disorder.

  3. Glycemic index, insulinemic index, and satiety index of kefir.

    Science.gov (United States)

    Kong, Kai Ling; Hendrich, Suzanne

    2012-08-01

    To determine glycemic, insulinemic, and satiety indices of 3 types of kefir. This study was divided into 3 phases. In phase 1, 50 g of available carbohydrate from low-fat strawberry kefir or orange kefir was tested, and in phase 2, low-fat plain kefir containing 25 g of available carbohydrates was tested for glycemic index (GI), in both cases compared with an equivalent amount of glucose. In phase 3, 1000-kJ portions of all 3 types of kefirs were compared with white bread with the same energy content to determine the insulinemic index (II) and satiety index (SI) of all 3 kefirs. In all phases, a single-meal, randomized crossover design was performed in which the test meals were given to healthy adults, 5 men and 5 women. The total incremental plasma glucose area under the curve (iAUC) for strawberry, orange, and plain kefirs was significantly lower compared with the respective high-GI control food, which was glucose solution. However, the IIs and SIs of kefir did not differ significantly from the white bread. Kefir is a low- to moderate-GI food; however, its II was high. Although kefir had higher water content, the SI of kefir was not significantly different from white bread.

  4. Renal abnormalities in congenital chloride diarrhea

    International Nuclear Information System (INIS)

    Al-Hamad, Nadia M.; Al-Eisa, Amal A.

    2004-01-01

    Congenital chloride diarrhea CLD is a rare autosomal recessive disorder caused by a defect in the chloride/ bicarbonate exchange in the ileum and colon. It is characterized by watery diarrhea, abdominal distension, hypochloremic hypokalemic metabolic alkalosis with high fecal content of chloride >90 mmol/l. We report 3 patients with CLD associated with various renal abnormalities including chronic renal failure secondary to renal hypoplasia, nephrocalcinosis and congenital nephrotic syndrome. (author)

  5. [Nutritional abnormalities in chronic obstructive pulmonary disease].

    Science.gov (United States)

    Gea, Joaquim; Martínez-Llorens, Juana; Barreiro, Esther

    2014-07-22

    Nutritional abnormalities are associated with chronic obstructive pulmonary disease with a frequency ranging from 2 to 50%, depending on the geographical area and the study design. Diagnostic tools include anthropometry, bioelectrical impedance, dual energy radioabsortiometry and deuterium dilution, being the body mass and the lean mass indices the most frequently used parameters. While the most important consequences of nutritional abnormalities are muscle dysfunction and exercise limitation, factors implicated include an imbalance between caloric intake and consumption, and between anabolic and catabolic hormones, inflammation, tobacco smoking, poor physical activity, hypoxemia, some drugs and aging/comorbidities. The most important molecular mechanism for malnutrition associated with chronic obstructive pulmonary disease appears to be the mismatching between protein synthesis and breakdown. Among the therapeutic measures proposed for these nutritional abnormalities are improvements in lifestyle and nutritional support, although the use of anabolic drugs (such as secretagogues of the growth hormone) offers a new therapeutic strategy. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  6. Content difference between normal and abnormal obsessions.

    Science.gov (United States)

    Rassin, Eric; Cougle, Jesse R; Muris, Peter

    2007-11-01

    Although it has long been thought that experiencing an obsession is a psychiatric symptom, more recent literature, has seen the normalisation of obsessions and other presumably clinical phenomena. That is, not only people suffering from psychiatric disorders experience obsessions but non-clinical individuals also do so. Furthermore, it has been argued that such normal obsessions are very similar to abnormal ones, in terms of content. However, in the present study, evidence was obtained indicating that normal and abnormal obsessions do differ in content. A sample of 133 healthy undergraduates was given a list of 70 obsessions, with some originating from obsessive-compulsive disorder (OCD) patients, and others stemming from healthy volunteers. Participants were asked to indicate whether they had ever experienced these obsessions. Participants endorsed significantly more normal than abnormal obsessions, suggesting that the two kinds of obsessions do differ from each other. In addition, the experience of clinical obsessions was more strongly associated with scores on a measure of OCD symptoms, than was the experience of normal obsessions.

  7. Abnormal Activity Detection Using Pyroelectric Infrared Sensors

    Directory of Open Access Journals (Sweden)

    Xiaomu Luo

    2016-06-01

    Full Text Available Healthy aging is one of the most important social issues. In this paper, we propose a method for abnormal activity detection without any manual labeling of the training samples. By leveraging the Field of View (FOV modulation, the spatio-temporal characteristic of human activity is encoded into low-dimension data stream generated by the ceiling-mounted Pyroelectric Infrared (PIR sensors. The similarity between normal training samples are measured based on Kullback-Leibler (KL divergence of each pair of them. The natural clustering of normal activities is discovered through a self-tuning spectral clustering algorithm with unsupervised model selection on the eigenvectors of a modified similarity matrix. Hidden Markov Models (HMMs are employed to model each cluster of normal activities and form feature vectors. One-Class Support Vector Machines (OSVMs are used to profile the normal activities and detect abnormal activities. To validate the efficacy of our method, we conducted experiments in real indoor environments. The encouraging results show that our method is able to detect abnormal activities given only the normal training samples, which aims to avoid the laborious and inconsistent data labeling process.

  8. Recurrent Cytogenetic Abnormalities in Acute Myeloid Leukemia.

    Science.gov (United States)

    Yang, John J; Park, Tae Sung; Wan, Thomas S K

    2017-01-01

    The spectrum of chromosomal abnormality associated with leukemogenesis of acute myeloid leukemia (AML) is broad and heterogeneous when compared to chronic myeloid leukemia and other myeloid neoplasms. Recurrent chromosomal translocations such as t(8;21), t(15;17), and inv(16) are frequently detected, but hundreds of other uncommon chromosomal aberrations from AML also exist. This chapter discusses 22 chromosomal abnormalities that are common structural, numerical aberrations, and other important but infrequent (less than 1 %) translocations emphasized in the WHO classification. Brief morphologic, cytogenetic, and clinical characteristics are summarized, so as to provide a concise reference to cancer cytogenetic laboratories. Morphology based on FAB classification is used together with the current WHO classification due to frequent mentioning in a vast number of reference literatures. Characteristic chromosomal aberrations of other myeloid neoplasms such as myelodysplastic syndrome and myeloproliferative neoplasm will be discussed in separate chapters-except for certain abnormalities such as t(9;22) in de novo AML. Gene mutations detected in normal karyotype AML by cutting edge next generation sequencing technology are also briefly mentioned.

  9. Spermatogenesis Abnormalities following Hormonal Therapy in Transwomen

    Directory of Open Access Journals (Sweden)

    Sirachai Jindarak

    2018-01-01

    Full Text Available Objective. To measure spermatogenesis abnormalities in transwomen at the time of sex reassignment surgery (SRS and to analyze the association between hormonal therapy duration and infertility severity. Design. Retrospective study. Setting. University hospital. Patients. One-hundred seventy-three transwomen who underwent SRS from January 2000 to December 2015. Interventions. All orchidectomy specimens were retrospectively reviewed and classified. History of hormonal therapy duration was retrieved from medical records. Main Outcome Measures. Histological examinations of orchidectomy specimens were performed to assess spermatogenesis. Results. One-hundred seventy-three orchidectomy specimens were evaluated. Histological examinations showed maturation arrest in 36.4%, hypospermatogenesis in 26%, Sertoli cell-only syndrome in 20.2%, normal spermatogenesis in 11%, and seminiferous tubule hyalinization in 6.4% of the specimens. Spermatogenesis abnormality severity was not associated with the total therapy duration (P=0.81 or patient age at the time of surgery (P=0.88. Testicular volumes and sizes were associated with spermatogenesis abnormality severity (P=0.001 and P=0.026, right testicle and left testicle, resp.. Conclusion(s. Feminizing hormonal treatment leads to reductions in testicular germ cell levels. All transwomen should be warned about this consequence, and gamete preservation should be offered before starting hormonal treatment.

  10. Using a pulse oximeter to determine clinical depth of anesthesia-investigation of the utility of the perfusion index.

    Science.gov (United States)

    Krishnamohan, Anirudh; Siriwardana, Viraj; Skowno, Justin J

    2016-11-01

    Peripheral vasodilation is a well-recognized side effect of general anesthesia, and induces changes in the amplitude of the pulse plethysmograph (PPG) waveform. This can be continuously quantitaed using the Perfusion Index (PI), a ratio of the pulsatile to nonpulsatile signal amplitude in the PPG waveform. We hypothesized that the perfusion index would rise with the induction of anesthesia in children, and fall with emergence, and performed a prospective, observational study to test this. Our primary aim was to test whether the different clinical stages of anesthesia were associated with changes in the perfusion index, and the secondary aim was to test the correlation between the normalized perfusion index and the MAC value. Twenty-one patients between the ages of 1 and 18 undergoing minor procedures with no anticipated painful stimuli were recruited. Patients with significant illnesses were excluded. Data collection commenced with a preinduction baseline, and data were collected continuously, with event marking, until completion of the anesthesia and removal of the pulse oximeter. Data collected included perfusion index, heart rate, and anesthetic gas concentration values. A normalized perfusion index was calculated by subtracting the initial baseline perfusion index value from all perfusion index values, allowing changes, from a standardized initial baseline value of zero, to be analyzed. During induction, the mean normalized perfusion index rose from 0.0 to 4.2, and then declined to 0.470 when the patients returned to consciousness. P < 0.001 using repeated measures anova test. The normalized perfusion index was correlated with MAC values (r 2 = 0.33, 95% CI 0.18-0.47, P < 0.01). The perfusion index changed significantly during different stages of anesthesia. There is a significant correlation between the perfusion index, measured by pulse oximetry, and the MAC value, in pediatric patients undergoing minor procedures. © 2016 John Wiley & Sons Ltd.

  11. Congenital abnormalities associated with hemivertebrae in relation to hemivertebrae location.

    Science.gov (United States)

    Bollini, Gerard; Launay, Franck; Docquier, Pierre-Louis; Viehweger, Elke; Jouve, Jean-Luc

    2010-01-01

    Numerous congenital abnormalities have been reported in association with hemivertebrae (HV). No data exist about their incidence depending on the location of the HV. From 1980 to 2003, 75 patients with 80 HV responsible for evolutive congenital scoliosis were managed by HV resection using a double approach and short anterior and posterior convex fusion. The associated abnormalities were evaluated with MRI, echocardiography and renal ultrasound. Associated genitourinary abnormalities were found in 24% of patients, cardiac abnormalities in 8% and intrathecal abnormalities in 15%. Medullar abnormalities were more frequent in case of vertebral malformations at lumbosacral level.

  12. Supplement: Commodity Index Report

    Data.gov (United States)

    Commodity Futures Trading Commission — Shows index traders in selected agricultural markets. These traders are drawn from the noncommercial and commercial categories. The noncommercial category includes...

  13. Evaluation of clinical characteristics of Kawasaki syndrome and risk factors for coronary artery abnormalities among children in Denmark.

    Science.gov (United States)

    Patel, Amy; Holman, Robert C; Callinan, Laura S; Sreenivasan, Nandini; Schonberger, Lawrence B; Fischer, Thea K; Belay, Ermias D

    2013-04-01

    To examine clinical characteristics, treatment and outcome of Kawasaki syndrome patients in Denmark. A retrospective chart review of hospitalization records for children Kawasaki syndrome discharge diagnosis identified through the Danish National Patient Registry during 1994 through June 2008 was conducted. A total of 284 cases Kawasaki syndrome (n = 279) and atypical Kawasaki syndrome (n = 5); 70.4% were Kawasaki syndrome patients were diagnosed with coronary artery abnormalities. Not receiving intravenous immunoglobulin treatment before the 10th day of illness, young age and male sex were significantly associated with the development of coronary artery abnormalities. In Denmark, more than one in 10 children with Kawasaki syndrome develop coronary artery abnormalities. Physicians should increase their index of suspicion for early diagnosis and treatment of Kawasaki syndrome among patients susceptible to increased risk of coronary artery abnormalities, particularly in infants who may have a more atypical presentation of the illness. ©2012 The Author(s)/Acta Paediatrica ©2013 Foundation Acta Paediatrica.

  14. Abnormal Size-Dependent Modulation of Motion Perception in Children with Autism Spectrum Disorder (ASD).

    Science.gov (United States)

    Sysoeva, Olga V; Galuta, Ilia A; Davletshina, Maria S; Orekhova, Elena V; Stroganova, Tatiana A

    2017-01-01

    Excitation/Inhibition (E/I) imbalance in neural networks is now considered among the core neural underpinnings of autism psychopathology. In motion perception at least two phenomena critically depend on E/I balance in visual cortex: spatial suppression (SS), and spatial facilitation (SF) corresponding to impoverished or improved motion perception with increasing stimuli size, respectively. While SS is dominant at high contrast, SF is evident for low contrast stimuli, due to the prevalence of inhibitory contextual modulations in the former, and excitatory ones in the latter case. Only one previous study (Foss-Feig et al., 2013) investigated SS and SF in Autism Spectrum Disorder (ASD). Our study aimed to replicate previous findings, and to explore the putative contribution of deficient inhibitory influences into an enhanced SF index in ASD-a cornerstone for interpretation proposed by Foss-Feig et al. (2013). The SS and SF were examined in 40 boys with ASD, broad spectrum of intellectual abilities (63 ASD. The presence of abnormally enhanced SF in children with ASD was the only consistent finding between our study and that of Foss-Feig et al. While the SS and SF indexes were strongly interrelated in TD participants, this correlation was absent in their peers with ASD. In addition, the SF index but not the SS index correlated with the severity of autism and the poor registration abilities. The pattern of results is partially consistent with the idea of hypofunctional inhibitory transmission in visual areas in ASD. Nonetheless, the absence of correlation between SF and SS indexes paired with a strong direct link between abnormally enhanced SF and autism symptoms in our ASD sample emphasizes the role of the enhanced excitatory influences by themselves in the observed abnormalities in low-level visual phenomena found in ASD.

  15. Browse Title Index

    African Journals Online (AJOL)

    Items 351 - 400 of 446 ... Vol 9, No 1 (2006), The effects of substance misuse on the personality traits of impulsivity and risky sexual decision-making, Abstract. Abeeb Olufemi Salaam. Vol 4, No 1 (1999), The efficacy of behavioural psychotherapy on abnormal sexual behaviours among the Nigerian clergy and the Catholic ...

  16. Browse Title Index

    African Journals Online (AJOL)

    Items 501 - 550 of 1463 ... ... No 1 (2014), Evaluation of Chromosomal Abnormalities and Common Trombophilic Mutations in Cases with Recurrent Miscarriage, Abstract PDF. Ahmet Karatas, Recep Eroz, Mustafa Albayrak, Tulay Ozlu, Bulent Cakmak, Fatih Keskin. Vol 16, No 1 (2016), Evaluation of factors affecting adherence ...

  17. Browse Title Index

    African Journals Online (AJOL)

    Items 101 - 150 of 462 ... Vol 17, No 1 (2016), Chromosomal abnormalities and autism, Abstract PDF. Farida El-Baz, Mohamed Saad Zaghloul, Ezzat El Sobky, Reham M Elhossiny, Heba Salah, Neveen Ezy Abdelaziz. Vol 12, No 1 (2011), Chromosomal study in newborn infants with congenital anomalies in Assiut University ...

  18. Browse Title Index

    African Journals Online (AJOL)

    Items 701 - 750 of 4084 ... Vol 85, No 11 (1995), Books: Respiratory Support, Abstract PDF. D.M. Linton. Vol 89, No 3 (1999), Books: Structural abnormalities and reproductive failure*, Abstract PDF. Zephne M van der Spuy. Vol 87, No 1 (1997), Books: The Cholesterol Myth. The New Healthy Heart Programme, Abstract PDF.

  19. Browse Title Index

    African Journals Online (AJOL)

    Items 1 - 50 of 174 ... C Ewhrudjakpor. Vol 10, No 1 (2012), Challenges to Effective Teaching of the Behavioural and Social Sciences to Medical Students in Nigeria. Abstract. BY Oladimeji. Vol 5, No 1 (2007), Changes in Attitudes Towards Mental illness after Exposure to a Course in Abnormal Psychology among Students of a ...

  20. Browse Title Index

    African Journals Online (AJOL)

    Items 751 - 781 of 781 ... Vol 30, No 2 (2003), Types and frequency of udder shapes and abnormalities in West African Dwarf and Red Sokoto goats, Abstract ... Vol 16, No 1 (1989), Variation in yield and composition of milk from different udder quarters of lactating White Fulani cattle in a tropical environment, Abstract.