DEFF Research Database (Denmark)
Nilsson, Brian; Goetze, Jens Peter; Chen, Xu
2009-01-01
AIMS: To investigate whether NT-proBNP before ablation treatment and after exercise testing has predictive information regarding the clinical outcome following pulmonary vein isolation in patients with atrial fibrillation (AF). METHODS: NT-proBNP analysis were obtained before the ablation (before...
Directory of Open Access Journals (Sweden)
Jelena Kornej
Full Text Available Arrhythmia recurrences after catheter ablation occur in up to 50% within one year but their prediction remains challenging. Recently, we developed a novel score for the prediction of rhythm outcomes after single AF ablation demonstrating superiority to other scores. The current study was performed to 1 prove the predictive value of the APPLE score in patients undergoing repeat AF ablation and 2 compare it with the CHADS2 and CHA2DS2-VASc scores.Rhythm outcome between 3-12 months after AF ablation were documented. The APPLE score (one point for Age >65 years, Persistent AF, imPaired eGFR (<60 ml/min/1.73m2, LA diameter ≥43 mm, EF <50% was calculated in every patient before procedure.379 consecutive patients from The Leipzig Heart Center AF Ablation Registry (60±10 years, 65% male, 70% paroxysmal AF undergoing repeat AF catheter ablation were included. Arrhythmia recurrences were observed in 133 patients (35%. While the CHADS2 (AUC 0.577, p = 0.037 and CHA2DS2-VASc scores (AUC 0.590, p = 0.015 demonstrated low predictive value, the APPLE score showed better prediction of arrhythmia recurrences (AUC 0.617, p = 0.002 than other scores (both p<0.001. Compared to patients with an APPLE score of 0, the risk (OR for arrhythmia recurrences was 2.9, 3.0 and 6.0 (all p<0.01 for APPLE scores 1, 2, or ≥3, respectively.The novel APPLE score is superior to the CHADS2 and CHA2DS2-VASc scores for prediction of rhythm outcomes after repeat AF catheter ablation. It may be helpful to identify patients with low, intermediate or high risk for recurrences after repeat procedure.
Zarzoso, Vicente; Latcu, Decebal G; Hidalgo-Muñoz, Antonio R; Meo, Marianna; Meste, Olivier; Popescu, Irina; Saoudi, Nadir
2016-12-01
Catheter ablation (CA) of persistent atrial fibrillation (AF) is challenging, and reported results are capable of improvement. A better patient selection for the procedure could enhance its success rate while avoiding the risks associated with ablation, especially for patients with low odds of favorable outcome. CA outcome can be predicted non-invasively by atrial fibrillatory wave (f-wave) amplitude, but previous works focused mostly on manual measures in single electrocardiogram (ECG) leads only. To assess the long-term prediction ability of f-wave amplitude when computed in multiple ECG leads. Sixty-two patients with persistent AF (52 men; mean age 61.5±10.4years) referred for CA were enrolled. A standard 1-minute 12-lead ECG was acquired before the ablation procedure for each patient. F-wave amplitudes in different ECG leads were computed by a non-invasive signal processing algorithm, and combined into a mutivariate prediction model based on logistic regression. During an average follow-up of 13.9±8.3months, 47 patients had no AF recurrence after ablation. A lead selection approach relying on the Wald index pointed to I, V1, V2 and V5 as the most relevant ECG leads to predict jointly CA outcome using f-wave amplitudes, reaching an area under the curve of 0.854, and improving on single-lead amplitude-based predictors. Analysing the f-wave amplitude in several ECG leads simultaneously can significantly improve CA long-term outcome prediction in persistent AF compared with predictors based on single-lead measures. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
International Nuclear Information System (INIS)
Wimmer, Thomas; Srimathveeravalli, Govindarajan; Gutta, Narendra; Ezell, Paula C.; Monette, Sebastien; Maybody, Majid; Erinjery, Joseph P.; Durack, Jeremy C.; Coleman, Jonathan A.; Solomon, Stephen B.
2015-01-01
PurposeNumerical simulations are used for treatment planning in clinical applications of irreversible electroporation (IRE) to determine ablation size and shape. To assess the reliability of simulations for treatment planning, we compared simulation results with empiric outcomes of renal IRE using computed tomography (CT) and histology in an animal model.MethodsThe ablation size and shape for six different IRE parameter sets (70–90 pulses, 2,000–2,700 V, 70–100 µs) for monopolar and bipolar electrodes was simulated using a numerical model. Employing these treatment parameters, 35 CT-guided IRE ablations were created in both kidneys of six pigs and followed up with CT immediately and after 24 h. Histopathology was analyzed from postablation day 1.ResultsAblation zones on CT measured 81 ± 18 % (day 0, p ≤ 0.05) and 115 ± 18 % (day 1, p ≤ 0.09) of the simulated size for monopolar electrodes, and 190 ± 33 % (day 0, p ≤ 0.001) and 234 ± 12 % (day 1, p ≤ 0.0001) for bipolar electrodes. Histopathology indicated smaller ablation zones than simulated (71 ± 41 %, p ≤ 0.047) and measured on CT (47 ± 16 %, p ≤ 0.005) with complete ablation of kidney parenchyma within the central zone and incomplete ablation in the periphery.ConclusionBoth numerical simulations for planning renal IRE and CT measurements may overestimate the size of ablation compared to histology, and ablation effects may be incomplete in the periphery
Ezzat, Vivienne A; Ryan, Matthew J; O'Leary, Justin; Ariti, Cono; Deanfield, John; Pandya, Bejal; Cullen, Shay; Walker, Fiona; Khan, Fakhar; Abrams, Dominic J; Lambiase, Pier D; Lowe, Martin D
2017-03-01
Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.
Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko
2017-09-01
This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in high-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P 10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria.
International Nuclear Information System (INIS)
Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko
2017-01-01
This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in nigh-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels <2 ng/ml in a TSH-stimulated state after ablation. We extracted data on patients' age, sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P < 0.001), while no significant differences were found for other factors between the groups. Furthermore, thyroglobulin levels >10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria. (author)
Atrial Fibrillation Ablation in Systolic Dysfunction: Clinical and Echocardiographic Outcomes
Directory of Open Access Journals (Sweden)
Tasso Julio Lobo
2015-01-01
Full Text Available Background: Heart failure and atrial fibrillation (AF often coexist in a deleterious cycle. Objective: To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF ablation. Methods: Patients with ventricular systolic dysfunction [ejection fraction (EF <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class and echocardiographic (EF, left atrial diameter data were compared (McNemar test and t test before and after ablation. Results: 31 patients (6 women, 25 men, aged 37 to 77 years (mean, 59.8±10.6, underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%. During a mean follow-up of 20.3±17 months, 24 patients (77% were in sinus rhythm, 11 (35% being on amiodarone. Eight patients (26% underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures. Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001. The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005 and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026. No major complications occurred. Conclusion: Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.
Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru
2018-02-01
Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF. We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAV max ) - Minimum LA volume (LAV min ), LA emptying fraction = [(LAV max - LAV min )/LAV max ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A 2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004). Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF. © 2017 Wiley Periodicals, Inc.
Zhou, Wenhui; Arellano, Ronald S
2018-04-06
To evaluate perioperative outcomes of thermal ablation with microwave (MW), radiofrequency (RF), and cryoablation for stage T1c renal cell carcinoma (RCC). A retrospective analysis of 384 patients (mean age, 71 y; range, 22-88 y) was performed between October 2006 and October 2016. Mean radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines; preoperative aspects and dimensions used for anatomic classification; and centrality index scores were 6.3, 7.9, and 2.7, respectively. Assessment of pre- and postablation serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate was performed to assess functional outcomes. Linear regression analyses were performed to compare sedation medication dosages among the three treatment cohorts. Univariable and multivariable logistic regression analyses were performed to compare rates of residual disease and complications among treatment modalities. A total of 437 clinical stage T1N0M0 biopsy-proven RCCs measuring 1.2-6.9 cm were treated with computed tomography (CT)-guided MW ablation (n = 44; 10%), RF ablation (n = 347; 79%), or cryoablation (n = 46; 11%). There were no significant differences in patient demographic or tumor characteristics among cohorts. Complication rates and immediate renal function changes were similar among the three ablation modalities (P = .46 and P = .08, respectively). MW ablation was associated with significantly decreased ablation time (P < .05), procedural time (P < .05), and dosage of sedative medication (P < .05) compared with RF ablation and cryoablation. CT-guided percutaneous MW ablation is comparable to RF ablation or cryoablation for the treatment of stage T1N0M0 RCC with regard to treatment response and is associated with shorter treatment times and less sedation than RF ablation or cryoablation. In addition, the safety profile of CT-guided MW ablation is noninferior to those of RF ablation or
Characterization of tracked radiofrequency ablation in phantom
International Nuclear Information System (INIS)
Chen, Chun-Cheng R.; Miga, Michael I.; Galloway, Robert L.
2007-01-01
In radiofrequency ablation (RFA), successful therapy requires accurate, image-guided placement of the ablation device in a location selected by a predictive treatment plan. Current planning methods rely on geometric models of ablations that are not sensitive to underlying physical processes in RFA. Implementing plans based on computational models of RFA with image-guided techniques, however, has not been well characterized. To study the use of computational models of RFA in planning needle placement, this work compared ablations performed with an optically tracked RFA device with corresponding models of the ablations. The calibration of the tracked device allowed the positions of distal features of the device, particularly the tips of the needle electrodes, to be determined to within 1.4±0.6 mm of uncertainty. Ablations were then performed using the tracked device in a phantom system based on an agarose-albumin mixture. Images of the sliced phantom obtained from the ablation experiments were then compared with the predictions of a bioheat transfer model of RFA, which used the positional data of the tracked device obtained during ablation. The model was demonstrated to predict 90% of imaged pixels classified as being ablated. The discrepancies between model predictions and observations were analyzed and attributed to needle tracking inaccuracy as well as to uncertainties in model parameters. The results suggest the feasibility of using finite element modeling to plan ablations with predictable outcomes when implemented using tracked RFA
International Nuclear Information System (INIS)
Sommer, C. M.; Arnegger, F.; Koch, V.; Pap, B.; Holzschuh, M.; Bellemann, N.; Gehrig, T.; Senft, J.; Nickel, F.; Mogler, C.; Zelzer, S.; Meinzer, H. P.; Stampfl, U.; Kauczor, H. U.; Radeleff, B. A.
2012-01-01
Purpose: This study was designed to analyze the effect of two different ablation modes (“temperature control” and “power control”) of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96°C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96°C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 ± 0 s in group I and 102 ± 21 s in group II. Long axis diameter was 20.3 ± 4.6 mm in group I and 19.8 ± 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 ± 2 mm in group I and 10.5 ± 2.4 mm in group II (NS). Circularity was 0.5 ± 0.1 in group I and 0.5 ± 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.
Zhang, Chengwei; Zhao, Xiaozhi; Guo, Suhan; Ji, Changwei; Wang, Wei; Guo, Hongqian
2018-05-15
To evaluate the perioperative outcomes of zero ischemia radiofrequency ablation-assisted tumor enucleation. Patients undergoing zero ischemia radiofrequency ablation-assisted tumor enucleation were retrospectively identified from July 2008 to March 2013. The tumor was enucleated after RFA treatment. R.E.N.A.L., PADUA and centrality index (C-index) score systems were used to assess each tumor case. We analyzed the correlation of perioperative outcomes with these scores. Postoperative complications were graded with Clavien-Dindo system. Multivariate logistic regression analyses were used to assess risk of complications. Among 182 patients assessed, median tumor size, estimated blood loss, hospital stay and operative time were 3.2 cm (IQR 2.8-3.4), 80 ml (IQR 50-120), 7 days (IQR 6-8) and 100 min (IQR 90-120), respectively. All three scoring systems were strongly correlated with estimated blood loss, hospital stay and operative time. We found 3 (1.6%) intraoperative and 23 (12.6%, 13 [7.1%] Grade 1 and 10 [5.5%] Grade 2 & 3a) postoperative complications. The median follow-up was 55.5 months (IQR 45-70). Additionally, the complexities of R.E.N.A.L., PADUA and C-index scores were significantly correlated with complication grades (P radiofrequency ablation-assisted tumor enucleation is considered an effective nephron-sparing treatment. Scoring systems could be useful for predicting perioperative outcomes of radiofrequency ablation-assisted tumor enucleation.
Prolonged PR interval predicts clinical recurrence of atrial fibrillation after catheter ablation.
Park, Junbeom; Kim, Tae-Hoon; Lee, Jihei Sara; Park, Jin Kyu; Uhm, Jae Sun; Joung, Boyoung; Lee, Moon Hyoung; Pak, Hui-Nam
2014-10-07
A prolonged PR interval is known to be a poor prognostic factor in cardiovascular disease. The aim of this study was to investigate the association between PR interval and clinical outcome in patients undergoing radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). We prospectively included 576 patients with AF (75.5% male, 57.8±11.6 years old, 68.8% paroxysmal AF) who underwent RFCA. We analyzed preprocedural sinus rhythm ECGs obtained in the absence of antiarrhythmic drug, and all enrolled patients were categorized into 4 groups based on the quartile values of the PR interval (166, 182, and 202 ms), and were analyzed according to the left atrium (LA) volume (CT; Computed tomography), LA voltage (NavX), and clinical outcome of AF ablation. Based on quartile value of PR interval, the highest quartile of PR interval (Q4; PR ≥202 ms) was oldest (PPR interval was a significant predictor of AF recurrence after RFCA of AF (HR=1.969, 95% CI 1.343 to 2.886, P=0.001). The PR interval was closely associated with advanced LA remodeling due to AF, and had a noninvasive significant predictive value of clinical recurrence of AF after RFCA. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Directory of Open Access Journals (Sweden)
Bashar Aldhoon
Full Text Available To investigate predictors of long-term outcomes after catheter ablation (CA for ventricular tachycardia (VT and the impact of electrical storm (ES prior to index ablation procedures.We studied consecutive patients with structural heart disease and VT (n = 328; age: 63±12 years; 88% males; 72% ischaemic cardiomyopathy; LVEF: 32±12% who had undergone CA. According to presenting arrhythmia at baseline, they were divided into ES (n = 93, 28% and non-ES groups. Clinical predictors of all-cause mortality were investigated and a clinically useful risk score (SCORE was constructed.During a median follow-up of 927 days (IQR: 564-1626, 67% vs. 60% of patients (p = 0.05 experienced VT recurrence in the ES vs. the non-ES group, respectively; and 41% vs. 32% patients died (p = 0.02, respectively. Five factors were independently associated with mortality: age >70 years (hazard ratio (HR: 1.6, 95% confidence interval (CI: 1.1-2.4, p = 0.01, NYHA class ≥3 (HR: 1.9, 95% CI: 1.2-2.9, p = 0.005, a serum creatinine level >1.3 mg/dL (HR: 1.6, 95% CI: 1.1-2.3, p = 0.02, LVEF ≤25% (HR: 2.4, 95% CI: 1.6-3.5, p = 0.00004, and amiodarone therapy (HR: 1.5, 95% CI: 1.0-2.2, p = 0.03. A risk SCORE ranging from 0-4 (1 point for either high-risk age, NYHA, creatinine, or LVEF correlated with mortality. ES during index ablation independently predicted mortality only in patients with a SCORE ≤1.Advanced LV dysfunction, older age, higher NYHA class, renal dysfunction, and amiodarone therapy, but not ES, were predictors of poor outcomes after CA for VT in the total population. However, ES did predict mortality in a low-risk sub-group of patients.
Yang, Jian-du; Sun, Qi; Guo, Xiao-Gang; Zhou, Gong-Bu; Liu, Xu; Luo, Bin; Wei, Hui-Qiang; Santangeli, Pasquale; Liang, Jackson J; Ma, Jian
2018-04-03
Right atrial dual-loop reentry tachycardia has been described in patients with open-heart surgery. However, the prevalence, electrophysiologic substrate and ablation outcomes have been poorly characterized. We aimed to investigate the prevalence, electrophysiologic substrate and ablation outcomes for RA dual-loop reentry tachycardia following cardiac surgery. We identified all patients with atrial tachycardia after cardiac surgery. We compared electrophysiologic findings and outcomes of those with RA dual-loop reentry tachycardia versus a control group of patients with RA macro-reentrant arrhythmias in the setting of linear RA free wall (FW) scar. Out of 127 patients with 152 post-surgical atrial tachycardias (ATs), 28 (18.4%) had diagnosis of RA dual-loop reentry and 24/28 (85.7%) had tricuspid annular (TA) reentry combined with FW incisional reentry. An incision length > 51.5mm along the FW predicted the substrate for a second loop. In 22/23 patients (95.7%) with initial ablation in the cavo-tricuspid isthmus, a change in the interval between Halo d to CS p could be recorded, while 15/23 patients (65.2%) had CS activation pattern change. Complete success was achieved in 25/28 (89.3%) and 64/69 (92.8%) in the dual-loop reentry and control groups, respectively. After mean follow-up of 33.9±24.2 months, 24/28 (85.7%) and 60/69 (86.95%) were free of arrhythmias after initial procedure in two groups. The prevalence of RA dual-loop reentry is 18.4% among ATs with prior atriotomy scar. A long incision should alert physician the possibility of the second loop at the FW. Halo and CS activation pattern are important clues for circuit transformation. Copyright © 2018. Published by Elsevier Inc.
Kahn, A; Al-Qaisi, M; Kommineni, V T; Callaway, J K; Boroff, E S; Burdick, G E; Lam-Himlin, D M; Temkit, M; Vela, M F; Ramirez, F C
2018-04-01
Radiofrequency ablation of Barrett's esophagus with low-grade dysplasia is recommended in recent American College of Gastroenterology guidelines, with endoscopic surveillance considered a reasonable alternative. Few studies have directly compared outcomes of radiofrequency ablation to surveillance and those that have are limited by short duration of follow-up. This study aims to compare the long-term effectiveness of radiofrequency ablation versus endoscopic surveillance in a large, longitudinal cohort of patients with Barrett's esophagus, and low-grade dysplasia.We conducted a retrospective analysis of patients with confirmed low-grade dysplasia at a single academic medical center from 1991 to 2014. Patients progressing to high-grade dysplasia or esophageal adenocarcinoma within one year of index LGD endoscopy were defined as missed dysplasia and excluded. Risk factors for progression were assessed via Cox proportional hazards model. Comparison of progression risk was conducted using a Kaplan-Meier analysis. Subset analyses were conducted to examine the effect of reintroducing early progressors and excluding patients diagnosed prior to the advent of ablative therapy. Of 173 total patients, 79 (45.7%) underwent radiofrequency ablation while 94 (54.3%) were untreated, with median follow up of 90 months. Seven (8.9%) patients progressed to high-grade dysplasia or adenocarcinoma despite ablation, compared with 14 (14.9%) undergoing surveillance (P = 0.44). This effect was preserved when patients diagnosed prior to the introduction of radiofrequency ablation were excluded (8.9% vs 13%, P = 0.68). Reintroduction of patients progressing within the first year of follow-up resulted in a trend toward significance for ablation versus surveillance (11.1% vs 23.8%, P = 0.053).In conclusion, progression to high-grade dysplasia or adenocarcinoma was not significantly reduced in the radiofrequency ablation cohort when compared to surveillance. Despite recent studies
Rozen, Guy; Ptaszek, Leon; Zilberman, Israel; Cordaro, Kevin; Heist, E Kevin; Beeckler, Christopher; Altmann, Andres; Ying, Zhang; Liu, Zhenjiang; Ruskin, Jeremy N; Govari, Assaf; Mansour, Moussa
2017-02-01
Real-time radiofrequency (RF) ablation lesion assessment is a major unmet need in cardiac electrophysiology. The purpose of this study was to assess whether improved temperature measurement using a novel thermocoupling (TC) technology combined with information derived from impedance change, contact force (CF) sensing, and catheter orientation allows accurate real-time prediction of ablation lesion formation. RF ablation lesions were delivered in the ventricles of 15 swine using a novel externally irrigated-tip catheter containing 6 miniature TC sensors in addition to force sensing technology. Ablation duration, power, irrigation rate, impedance drop, CF, and temperature from each sensor were recorded. The catheter "orientation factor" was calculated using measurements from the different TC sensors. Information derived from all the sources was included in a mathematical model developed to predict lesion depth and validated against histologic measurements. A total of 143 ablation lesions were delivered to the left ventricle (n = 74) and right ventricle (n = 69). Mean CF applied during the ablations was 14.34 ± 3.55g, and mean impedance drop achieved during the ablations was 17.5 ± 6.41 Ω. Mean difference between predicted and measured ablation lesion depth was 0.72 ± 0.56 mm. In the majority of lesions (91.6%), the difference between estimated and measured depth was ≤1.5 mm. Accurate real-time prediction of RF lesion depth is feasible using a novel ablation catheter-based system in conjunction with a mathematical prediction model, combining elaborate temperature measurements with information derived from catheter orientation, CF sensing, impedance change, and additional ablation parameters. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Milos, Frank S.
2011-01-01
In most previous work at NASA Ames Research Center, ablation predictions for carbonaceous materials were obtained using a species thermodynamics database developed by Aerotherm Corporation. This database is derived mostly from the JANAF thermochemical tables. However, the CEA thermodynamics database, also used by NASA, is considered more up to date. In this work, the FIAT code was modified to use CEA-based curve fits for species thermodynamics, then analyses using both the JANAF and CEA thermodynamics were performed for carbon and carbon phenolic materials over a range of test conditions. The ablation predictions are comparable at lower heat fluxes where the dominant mechanism is carbon oxidation. However, the predictions begin to diverge in the sublimation regime, with the CEA model predicting lower recession. The disagreement is more significant for carbon phenolic than for carbon, and this difference is attributed to hydrocarbon species that may contribute to the ablation rate.
On-line pachymetry outcome of ablation in aberration free mode TransPRK.
Adib-Moghaddam, Soheil; Arba-Mosquera, Samuel; Salmanian, Bahram; Omidvari, Amir-Houshang; Noorizadeh, Farsad
2014-01-01
There are many independent factors that influence the outcome of refractive surgeries, consisting of patient characteristics and environmental factors. We studied the accuracy of central ablation depth compared to online pachymetry results. A total of 153 eyes that underwent TransPRK at Bina Eye Hospital, Tehran, Iran, were evaluated from November 2010 to January 2012 in a retrospective cross-sectional study. The relevant data were registered and bivariate correlations and linear regression association were investigated statistically. The mean age was 29 ± 5 years. Distribution of refractive errors was as follows: compound myopic astigmatism 123 (80.4%), simple myopia 24 (15.7%), and mixed astigmatism 6 (3.9%). Mean ambient temperature and humidity levels intraoperatively were 23.49 ± 1.16°C and 28.91 ± 6.16%, respectively. There was a significant difference (p<0.001) between the preassumed central ablation depth (131.68 ± 32.72 µm) and the net level of ablation depth (measured by online pachymetry, 168.04 ± 41.47 µm). Temperature and humidity levels were not in any statistically significant correlation with the net amount of difference found. The backward linear regression was done to reveal the association between ablation depth and several variables. This study showed that there is deviation in optical coherence pachymetry online measurements done with SCHWIND AMARIS laser. Ambient temperature and humidity levels intraoperatively do not influence the outcome. However, basic structural characteristics of patients along with change in refractive index and corneal shrinkage because of corneal dehydration are associated with the differences.
McCormick, Zachary L; Reddy, Rajiv; Korn, Marc; Dayanim, David; Syed, Raafay H; Bhave, Meghan; Zhukalin, Mikhail; Choxi, Sarah; Ebrahimi, Ali; Kendall, Mark C; McCarthy, Robert J; Khan, Dost; Nagpal, Geeta; Bouffard, Karina; Walega, David R
2017-12-28
Genicular nerve radiofrequency ablation is an effective treatment for patients with chronic pain due to knee osteoarthritis; however, little is known about factors that predict procedure success. The current study evaluated the utility of genicular nerve blocks to predict the outcome of genicular nerve cooled radiofrequency ablation (cRFA) in patients with osteoarthritis. This randomized comparative trial included patients with chronic knee pain due to osteoarthritis. Participants were randomized to receive a genicular nerve block or no block prior to cRFA. Patients receiving a prognostic block that demonstrated ≥50% pain relief for six hours received cRFA. The primary outcome was the proportion of participants with ≥50% reduction in knee pain at six months. Twenty-nine participants (36 knees) had cRFA following a prognostic block, and 25 patients (35 knees) had cRFA without a block. Seventeen participants (58.6%) in the prognostic block group and 16 (64.0%) in the no block group had ≥50% pain relief at six months (P = 0.34). A 15-point decrease in the Western Ontario and McMaster Universities Osteoarthritis Index at six months was present in 17 of 29 (55.2%) in the prognostic block group and 15 of 25 (60%) in the no block group (P = 0.36). This study demonstrated clinically meaningful improvements in pain and physical function up to six months following cRFA. A prognostic genicular nerve block using a local anesthetic volume of 1 mL at each injection site and a threshold of ≥ 50% pain relief for subsequent cRFA eligibility did not improve the rate of treatment success. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Short and medium term outcomes after rollerball endometrial ablation for menorrhagia.
Fraser, I S; Angsuwathana, S; Mahmoud, F; Yezerski, S
1993-04-05
To review prospectively the intraoperative, short and medium term outcomes of patients treated by rollerball endometrial ablation during the learning curve for this relatively new procedure. Seventy-seven women with menorrhagia (71 with dysfunctional bleeding; six with additional small intramural myomas) underwent hysteroscopic rollerball endometrial ablation by coagulation diathermy during 1.5% glycine irrigation, after a two-month period of hormonal suppression. OPERATIVE AND SHORT-TERM EFFECTS: These were recorded at operation and six-week follow-up. No serious short-term complications were recorded. Objective measurement of intraoperative blood loss was always less than 20 mL. One woman experienced uterine perforation with a narrow cervical dilator which did not interfere with the ablation, and two patients had mild postoperative uterine infections. One patient experienced persistent postoperative pain. MEDIUM-TERM OUTCOME: This was recorded at each visit, or by telephone, and confirmed by questionnaire at one year. Twenty-five per cent achieved complete amenorrhoea, 29% staining only, 30% light periods, 10% "normal" or erratic periods and 6% were unchanged. Five patients underwent a second ablation, and three of these later underwent hysterectomy. Measured menstrual blood loss fell from 104 +/- 19 mL (mean +/- standard error of mean) to 1.7 +/- 1.1 mL at six months in 18 women. Other menstrual symptoms were also often dramatically reduced. Of those women with dysmenorrhoea, 33% were cured and 43% markedly improved; of those with midcycle pain, 28% were cured and 53% markedly improved; of those with significant premenstrual symptoms, 13% were cured, 47% markedly improved, 11% unchanged, and 6% were worse. This new procedure is a safe and effective treatment for menorrhagia caused by dysfunctional uterine bleeding, with impressive ancillary benefits for dysmenorrhoea, midcycle pain and premenstrual tension. It is often called minimally invasive surgery, but it
Role of percent peripheral tissue ablated on refractive outcomes following hyperopic LASIK
Stapleton, Fiona; Versace, Patrick
2017-01-01
Objectives To determine the effect of hyperopic laser in situ keratomileusis (H-LASIK) on corneal integrity, by investigating relationships between proportionate corneal tissue ablated and refractive outcomes at 3 months. Methods 18 eyes of 18 subjects treated with H-LASIK by Technolas 217c Excimer Laser were included in the study. Orbscan II Topography System was used to determine corneal volume and pachymetry 3mm temporally (3T). The volume of corneal tissue ablated was determined from the laser nomogram. Univariate associations between age, treatment, corneal volume, overall proportion of tissue removed, proportion of tissue removed at 3T, residual bed thickness at 3T and refractive outcomes 3 months post-LASIK were examined and independent factors associated with refractive outcomes determined using linear regression models. Results At 3 months post-LASIK, the mean difference to expected refractive outcome was -0.20 ± 0.64 (Range -2.00 to +1.00). In univariate analysis, difference to expected refractive outcome was associated with proportion of tissue removed at 3T (PLASIK, may present as either over or under-corrected at 3 months. The proportion of tissue removed at 3T was the single significant determinant of this outcome, suggesting unexpected biomechanical alterations resulting in corneal steepening. Future hyperopic LASIK procedures could consider proportionate volume of corneal tissue removed at 3T in addition to laser nomograms to achieve improved refractive outcomes. PMID:28151939
Shim, Jaemin; Hwang, Minki; Song, Jun-Seop; Lim, Byounghyun; Kim, Tae-Hoon; Joung, Boyoung; Kim, Sung-Hwan; Oh, Yong-Seog; Nam, Gi-Byung; On, Young Keun; Oh, Seil; Kim, Young-Hoon; Pak, Hui-Nam
2017-01-01
Objective: Radiofrequency catheter ablation for persistent atrial fibrillation (PeAF) still has a substantial recurrence rate. This study aims to investigate whether an AF ablation lesion set chosen using in-silico ablation (V-ABL) is clinically feasible and more effective than an empirically chosen ablation lesion set (Em-ABL) in patients with PeAF. Methods: We prospectively included 108 patients with antiarrhythmic drug-resistant PeAF (77.8% men, age 60.8 ± 9.9 years), and randomly assigned them to the V-ABL ( n = 53) and Em-ABL ( n = 55) groups. Five different in-silico ablation lesion sets [1 pulmonary vein isolation (PVI), 3 linear ablations, and 1 electrogram-guided ablation] were compared using heart-CT integrated AF modeling. We evaluated the feasibility, safety, and efficacy of V-ABL compared with that of Em-ABL. Results: The pre-procedural computing time for five different ablation strategies was 166 ± 11 min. In the Em-ABL group, the earliest terminating blinded in-silico lesion set matched with the Em-ABL lesion set in 21.8%. V-ABL was not inferior to Em-ABL in terms of procedure time ( p = 0.403), ablation time ( p = 0.510), and major complication rate ( p = 0.900). During 12.6 ± 3.8 months of follow-up, the clinical recurrence rate was 14.0% in the V-ABL group and 18.9% in the Em-ABL group ( p = 0.538). In Em-ABL group, clinical recurrence rate was significantly lower after PVI+posterior box+anterior linear ablation, which showed the most frequent termination during in-silico ablation (log-rank p = 0.027). Conclusions: V-ABL was feasible in clinical practice, not inferior to Em-ABL, and predicts the most effective ablation lesion set in patients who underwent PeAF ablation.
International Nuclear Information System (INIS)
Santra, Amburanjan; Maharjan, S.; Bal, C.
2010-01-01
Full text: Completion thyroidectomy (CT) is usually recommended after partial surgery in patients with differentiated thyroid cancer. Radioiodine lobar ablation (RAILA) is an easy alternative and avoids complications that might be associated with re-surgery. But its effectiveness in terms of long-term outcome and recurrence free survival is yet to be established. This study was aimed to compare long term outcome of RAILA with that of completion thyroidectomy. Materials and Methods: A retrospective analysis was done from the case records of patients treated in our thyroid clinic for last 25 years. Records of all patients of RAILA (364) and CT (372) were analyzed. Complete ablation rate, cumulative dose needed for complete ablation, Recurrence rate and recurrence free survival was estimated in each group. Comparison was made between two groups by statistical method. Results: There was 73% ablation rate at 1st dose of RAILA itself. Second dose in LA and first dose of remnant ablation after CT is comparable (92% and 93% respectively). Cumulative dose to achieve 100% ablation rate is more for RAILA group. Seven patients developed recurrence in RAILA group, compared to 14 in CT group. No statistically significant difference was noted between recurrence rate and recurrence free survival between two groups. Conclusion: Radioiodine Lobar ablation is a safe, effective and less costly alternative to completion thyroidectomy in patients with differentiated thyroid cancer with comparable long term outcome like recurrence rate and recurrence free survival
Energy Technology Data Exchange (ETDEWEB)
Xu, H.-X. [Department of Medical Ultrasonics, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Lu, M.-D. [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Xie, X.-Y. [Department of Medical Ultrasonics, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Yin, X.-Y. [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Kuang, M. [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Chen, J.-W. [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Xu, Z.-F. [Department of Medical Ultrasonics, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Liu, G.-J. [Department of Medical Ultrasonics, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China)
2005-09-01
AIM: To identify prognostic factors for long-term outcome for patients with hepatocellular carcinoma (HCC) after percutaneous microwave or radiofrequency ablation. MATERIALS AND METHODS: In total, 137 consecutive patients with HCC underwent microwave or radiofrequency ablation with curative intent; 16 possible prognostic factors were evaluated for their association with overall survival (OS) and disease-free survival (DFS) using univariate and multivariate analysis. RESULTS: The median OS and DFS were 27.0 months and 8.2 months, respectively. OS rates for all patients at 1, 2, 3, 4 and 5 years were 73.9%, 52.1%, 42.8%, 26.2% and 20.1%, respectively. DFS rates at 1, 2, 3 and 4 years were 38.1%, 21.9%, 18.8%, and 14.1%, respectively. Pretreatment serum alpha-fetoprotein (AFP) >200 ng/ml, pretreatment serum albumin {<=}35 g/dl, liver function Child's class C and incomplete ablation were found to be significant predictors for OS by univariate analysis. Using multivariate analysis, incomplete ablation was identified to be the most significant independent predictor for OS. Other independent predictors for OS were serum albumin level, serum AFP level and Child-Pugh classification. Recurrence after hepatectomy and prothrombin time >14 s were identified to be significant predictors for DFS by univariate analysis, and the former was the only independent predictor for DFS by multivariate analysis. CONCLUSION: Prognosis for patients with HCC after thermal ablation with curative intent was determined by treatment response to ablation, pretreatment serum AFP, and liver function reserve. Tumour response to treatment was the most predictive factor for long-term survival and was related to tumour size, thus careful selection of patients for ablation therapy is recommended.
International Nuclear Information System (INIS)
Xu, H.-X.; Lu, M.-D.; Xie, X.-Y.; Yin, X.-Y.; Kuang, M.; Chen, J.-W.; Xu, Z.-F.; Liu, G.-J.
2005-01-01
AIM: To identify prognostic factors for long-term outcome for patients with hepatocellular carcinoma (HCC) after percutaneous microwave or radiofrequency ablation. MATERIALS AND METHODS: In total, 137 consecutive patients with HCC underwent microwave or radiofrequency ablation with curative intent; 16 possible prognostic factors were evaluated for their association with overall survival (OS) and disease-free survival (DFS) using univariate and multivariate analysis. RESULTS: The median OS and DFS were 27.0 months and 8.2 months, respectively. OS rates for all patients at 1, 2, 3, 4 and 5 years were 73.9%, 52.1%, 42.8%, 26.2% and 20.1%, respectively. DFS rates at 1, 2, 3 and 4 years were 38.1%, 21.9%, 18.8%, and 14.1%, respectively. Pretreatment serum alpha-fetoprotein (AFP) >200 ng/ml, pretreatment serum albumin ≤35 g/dl, liver function Child's class C and incomplete ablation were found to be significant predictors for OS by univariate analysis. Using multivariate analysis, incomplete ablation was identified to be the most significant independent predictor for OS. Other independent predictors for OS were serum albumin level, serum AFP level and Child-Pugh classification. Recurrence after hepatectomy and prothrombin time >14 s were identified to be significant predictors for DFS by univariate analysis, and the former was the only independent predictor for DFS by multivariate analysis. CONCLUSION: Prognosis for patients with HCC after thermal ablation with curative intent was determined by treatment response to ablation, pretreatment serum AFP, and liver function reserve. Tumour response to treatment was the most predictive factor for long-term survival and was related to tumour size, thus careful selection of patients for ablation therapy is recommended
Reinhardt, Martin; Brandmaier, Philipp; Seider, Daniel; Kolesnik, Marina; Jenniskens, Sjoerd; Sequeiros, Roberto Blanco; Eibisberger, Martin; Voglreiter, Philip; Flanagan, Ronan; Mariappan, Panchatcharam; Busse, Harald; Moche, Michael
2017-12-01
Radio-frequency ablation (RFA) is a promising minimal-invasive treatment option for early liver cancer, however monitoring or predicting the size of the resulting tissue necrosis during the RFA-procedure is a challenging task, potentially resulting in a significant rate of under- or over treatments. Currently there is no reliable lesion size prediction method commercially available. ClinicIMPPACT is designed as multicenter-, prospective-, non-randomized clinical trial to evaluate the accuracy and efficiency of innovative planning and simulation software. 60 patients with early liver cancer will be included at four European clinical institutions and treated with the same RFA system. The preinterventional imaging datasets will be used for computational planning of the RFA treatment. All ablations will be simulated simultaneously to the actual RFA procedure, using the software environment developed in this project. The primary outcome measure is the comparison of the simulated ablation zones with the true lesions shown in follow-up imaging after one month, to assess accuracy of the lesion prediction. This unique multicenter clinical trial aims at the clinical integration of a dedicated software solution to accurately predict lesion size and shape after radiofrequency ablation of liver tumors. Accelerated and optimized workflow integration, and real-time intraoperative image processing, as well as inclusion of patient specific information, e.g. organ perfusion and registration of the real RFA needle position might make the introduced software a powerful tool for interventional radiologists to optimize patient outcomes.
Lee, Sunyoung; Kang, Tae Wook; Cha, Dong Ik; Song, Kyoung Doo; Lee, Min Woo; Rhim, Hyunchul; Lim, Hyo Keun; Sinn, Dong Hyun; Kim, Jong Man; Kim, Kyunga
2018-07-01
The therapeutic outcomes of surgical resection (SR) or radiofrequency ablation (RFA) for perivascular hepatocellular carcinoma (HCC) have not been compared. The aim of this study was to compare SR with RFA as first-line treatment in patients with perivascular HCC and to evaluate the long-term outcomes of both therapies. This retrospective study was approved by the institutional review board. The requirement for informed consent was waived. Between January 2006 and December 2010, a total of 283 consecutive patients with small perivascular HCCs (≤3 cm, Barcelona Clinic Liver Cancer stage 0 or A) underwent SR (n = 182) or RFA (n = 101) as a first-line treatment. The progression-free survival (PFS) and overall survival (OS) rates were compared by propensity score matching. Subgroup analysis of these outcomes was conducted according to the type of hepatic vessels. The median follow-up was 7.8 years. Matching yielded 62 pairs of patients. In the two matched groups, the PFS rates at 5 and 10 years were 58.0% and 17.8%, respectively, in the SR group, and 25.4% and 14.1%, respectively, in the RFA group (p radiofrequency ablation are both treatment options for perivascular hepatocellular carcinoma. We compared outcomes in patients treated with either method. Surgical resection provided better long-term tumor control and overall survival than radiofrequency ablation for patients with a small perivascular hepatocellular carcinoma (≤3 cm) as a first-line treatment, particularly for periportal tumors. The location of the tumor and the type of peritumoral hepatic vessels need to be considered when choosing between surgical resection and radiofrequency ablation for small HCCs. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Vallejo Casas, Juan A; Mena Bares, Luisa M; Gálvez Moreno, Maria A; Moreno Ortega, Estefanía; Marlowe, Robert J; Maza Muret, Francisco R; Albalá González, María D
2016-06-01
Most publications to date compare outcomes after post-surgical thyroid remnant ablation stimulated by recombinant human thyrotropin (rhTSH) versus thyroid hormone withholding/withdrawal (THW) in low-recurrence risk differentiated thyroid carcinoma (DTC) patients. We sought to perform this comparison in high-risk patients. We retrospectively analyzed ~9-year single-center experience in 70 consecutive adults with initial UICC (Union for International Cancer Control) stage III/IV, M0 DTC undergoing rhTSH-aided (N.=54) or THW-aided (N.=16) high-activity ablation. Endpoints included ablation success and DTC outcome. Assessed ≥1 year post-ablation, ablation success comprised a) no visible scintigraphic thyroid bed uptake or pathological extra-thyroidal uptake; b) undetectable stimulated serum thyroglobulin (Tg) without interfering autoantibodies; c) both criteria. DTC outcome, determined at the latest visit, comprised either 1) "no evidence of disease" (NED): undetectable Tg, negative Tg autoantibodies, negative most recent whole-body scan, no suspicious findings clinically, on neck ultrasonography, or on other imaging; 2) persistent disease: failure to attain NED; or 3) recurrence: loss of NED. After the first ablative activity, ablation success by scintigraphic plus biochemical criteria was 64.8% in rhTSH patients, 56.3% in THW patients (P=NS). After 3.5-year versus 6.2-year median follow-up (P<0.05), DTC outcomes were NED, 85.2%, persistent disease, 13.0%, recurrence, 1.9%, in the rhTSH group and NED, 87.5%, persistent or recurrent disease, 6.3% each, in the THW group (P=NS). In patients with initial stage III/IV, M0 DTC, rhTSH-aided and THW-assisted ablation were associated with comparable remnant eradication or DTC cure rates.
Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.
Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil
2012-05-01
Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Kele, Petra G.; de Jong, Koert P.; van der Jagt, Eric J.
Purpose: To test the hypothesis that volume changes of ablation zones (AZs) on successive computed tomography (CT) scans could predict ablation site recurrences (ASRs) in patients with colorectal liver metastases treated by radiofrequency (RF) ablation. Materials and Methods: RF ablation was
Non-Fourier based thermal-mechanical tissue damage prediction for thermal ablation.
Li, Xin; Zhong, Yongmin; Smith, Julian; Gu, Chengfan
2017-01-02
Prediction of tissue damage under thermal loads plays important role for thermal ablation planning. A new methodology is presented in this paper by combing non-Fourier bio-heat transfer, constitutive elastic mechanics as well as non-rigid motion of dynamics to predict and analyze thermal distribution, thermal-induced mechanical deformation and thermal-mechanical damage of soft tissues under thermal loads. Simulations and comparison analysis demonstrate that the proposed methodology based on the non-Fourier bio-heat transfer can account for the thermal-induced mechanical behaviors of soft tissues and predict tissue thermal damage more accurately than classical Fourier bio-heat transfer based model.
Luckett, Tyler; Allamneni, Chaitanya; Cowley, Kevin; Eick, John; Gullick, Allison; Peter, Shajan
2018-05-21
We aim to investigate factors that may contribute to failure of eradication of dysplastic Barrett's Esophagus among patients undergoing radiofrequency ablation treatment. A retrospective review of patients undergoing radiofrequency ablation for treatment of Barrett's Esophagus was performed. Data analyzed included patient demographics, medical history, length of Barrett's Esophagus, number of radiofrequency ablation sessions, and histopathology. Subsets of patients achieving complete eradication were compared with those not achieving complete eradication. A total of 107 patients underwent radiofrequency ablation for Barrett's Esophagus, the majority white, overweight, and male. Before treatment, 63 patients had low-grade dysplasia, and 44 patients had high-grade dysplasia or carcinoma. Complete eradication was achieved in a majority of patients (57% for metaplasia, and 76.6% for dysplasia). Failure of eradication occurred in 15.7% of patients. The median number of radiofrequency ablation treatments in patients achieving complete eradication was 3 sessions, compared to 4 sessions for failure of eradication (p = 0.06). Barrett's esophagus length of more than 5 cm was predictive of failure of eradication (p Radiofrequency ablation for dysplastic Barrett's Esophagus is a proven and effective treatment modality, associated with a high rate of complete eradication. Our rates of eradication from a center starting an ablation program are comparable to previously published studies. Length of Barrett's segment > 5 cm was found to be predictive of failure of eradication in patients undergoing radiofrequency ablation.
Ablation of Solid Hydrogen in a Plasma
DEFF Research Database (Denmark)
Jørgensen, L. W.; Sillesen, Alfred Hegaard
1979-01-01
Several hydrogen pellet ablation models based on the formation of a shielding neutral cloud have been reported by different authors. The predicted ablation rates are shown to follow almost the same scaling law and this is used to explain the authors' ablation experiment.......Several hydrogen pellet ablation models based on the formation of a shielding neutral cloud have been reported by different authors. The predicted ablation rates are shown to follow almost the same scaling law and this is used to explain the authors' ablation experiment....
Shoemaker, M. Benjamin; Muhammad, Raafia; Parvez, Babar; White, Brenda W.; Streur, Megan; Song, Yanna; Stubblefield, Tanya; Kucera, Gayle; Blair, Marcia; Rytlewski, Jason; Parvathaneni, Sunthosh; Nagarakanti, Rangadham; Saavedra, Pablo; Ellis, Christopher; Whalen, S. Patrick; Roden, Dan M; Darbar, Dawood
2012-01-01
Background Common single nucleotide polymorphisms (SNPs) at chromosome 4q25 (rs2200733, rs10033464) are associated with both lone and typical AF. Risk alleles at 4q25 have recently been shown to predict recurrence of AF after ablation in a population of predominately lone AF, but lone AF represents only 5–30% of AF cases. Objective To test the hypothesis that 4q25 AF risk alleles can predict response to AF ablation in the majority of AF cases. Methods Patients enrolled in the Vanderbilt AF Registry underwent 378 catheter-based AF ablations (median age 60 years, 71% male, 89% typical AF) between 2004 and 2011. The primary endpoint was time to recurrence of any non-sinus atrial tachyarrhythmia (atrial tachycardia, atrial flutter, or AF; [AT/AF]). Results Two-hundred AT/AF recurrences (53%) were observed. In multivariable analysis, the rs2200733 risk allele predicted a 24% shorter recurrence-free time (survival time ratio 0.76 95% confidence interval [CI] 0.6–0.95, P=0.016) compared with wild-type. The heterozygous haplotype demonstrated a 21% shorter recurrence-free time (survival time ratio = 0.79, 95% CI 0.62–0.99) and the homozygous risk allele carriers a 39% shorter recurrence-free time (survival time ratio = 0.61, 95% CI 0.37–1.0) (P=0.037). Conclusion Risk alleles at the 4q25 loci predict impaired clinical response to AF ablation in a population of predominately typical AF patients. Our findings suggest the rs2200733 polymorphism may hold promise as an as an objectively measured patient characteristic that can used as a clinical tool for selection of patients for AF ablation. PMID:23178686
DEFF Research Database (Denmark)
Wagner, Mette Kirstine; Zwisler, Ann-Dorthe Olsen; Risom, Signe Stelling
2018-01-01
(EHRA) score I-II had a positive effect of rehabilitation. CONCLUSION: The results suggest that sex differences exist in self-reported health after rehabilitation in patients ablated for AF. Patients with an I-II EHRA score seem more likely to gain from the rehabilitation programme compared with those......BACKGROUND: Increased physical capacity after comprehensive rehabilitation in patients with atrial fibrillation (AF) undergoing ablation has been found in the CopenHeartRFA trial. The purpose of this study was to investigate: (a) sex differences in health status, psychological distress and quality...... of life, (b) sex differences in rehabilitation outcomes and (c) predictors of effect of rehabilitation. METHODS: We conducted an exploratory analysis of data from the randomized CopenHeartRFA trial, where patients treated with ablation were randomized with 1:1 to comprehensive rehabilitation consisting...
Radiofrequency ablation of liver tumors (II): clinical application and outcomes.
Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius
2010-01-01
Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.
Fragakis, Nikolaos; Krexi, Lydia; Kyriakou, Panagiota; Sotiriadou, Melani; Lazaridis, Charalambos; Karamanolis, Athanasios; Dalampyras, Panagiotis; Tsakiroglou, Stelios; Skeberis, Vassilios; Tsalikakis, Dimitrios; Vassilikos, Vassilios
2018-01-01
Radiofrequency (RF) ablation of the slow pathway (SP) in atrioventricular nodal reentry tachycardia (AVNRT) is occasionally complicated with atrioventricular block (AVB) often predicted by junctional beats (JB) with loss of ventriculo-atrial (VA) conduction. We analyzed retrospectively 153 patients undergoing ablation of SP for typical AVNRT. Patients were divided into two age groups: 127 ≤ 70 years and 26 > 70 years. We analyzed the interval between the atrial electrogram in the His-bundle position and the distal ablation catheter [A(H)-A(RFd)] and between the distal ablation catheter and the proximal coronary sinus catheter [A(RFd)-A(CS)] before RF applications with and without JB. We evaluated if these intervals can be used as predictors of JB incidence and also of JB with loss of VA conduction. We also assessed if age influences the risk of loss of VA conduction. The A(H)-A(RFd) and A(RFd)-A(CS) intervals were significantly shorter in RF applications causing JB than those without JB (33 ± 11 ms vs 39 ± 9 ms, P JB with VA block than those with VA conduction (29 ± 11 ms vs 35 ± 11 ms, P 70 years had shorter intervals (36 ± 11 ms vs 29 ± 8 ms, P = 0.012, 17 ± 8 ms vs 13 ± 7 ms, P = 0.027, respectively), while VA block was more common in this age group. The A(H)-A(RFd) and A(RFd)-A(CS) intervals can be used as markers for predicting JB occurrence as well as impending AVB. JB with loss of VA conduction occur more often in older patients possibly due to a higher position of SP. © 2017 Wiley Periodicals, Inc.
Roberton, Benjamin J; Liu, David; Power, Mark; Wan, John M C; Stuart, Sam; Klass, Darren; Yee, John
2014-05-01
Percutaneous image-guided thermal ablation is safe and efficacious in achieving local control and improving outcome in the treatment of both early stage non-small-cell lung cancer and pulmonary metastatic disease, in which surgical treatment is precluded by comorbidity, poor cardiorespiratory reserve, or unfavorable disease distribution. Radiofrequency ablation is the most established technology, but new thermal ablation technologies such as microwave ablation and cryoablation may offer some advantages. The use of advanced techniques, such as induced pneumothorax and the popsicle stick technique, or combining thermal ablation with radiotherapy, widens the treatment options available to the multidisciplinary team. The intent of this article is to provide the reader with a practical knowledge base of pulmonary ablation by concentrating on indications, techniques, and follow-up. Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Chik, William W B; Kosobrodov, Roman; Bhaskaran, Abhishek; Barry, Michael Anthony Tony; Nguyen, Doan Trang; Pouliopoulos, Jim; Byth, Karen; Sivagangabalan, Gopal; Thomas, Stuart P; Ross, David L; McEwan, Alistair; Kovoor, Pramesh; Thiagalingam, Aravinda
2015-04-01
Steam pop is an explosive rupture of cardiac tissue caused by tissue overheating above 100 °C, resulting in steam formation, predisposing to serious complications associated with radiofrequency (RF) ablations. However, there are currently no reliable techniques to predict the occurrence of steam pops. We propose the utility of acoustic signals emitted during RF ablation as a novel method to predict steam pop formation and potentially prevent serious complications. Radiofrequency generator parameters (power, impedance, and temperature) were temporally recorded during ablations performed in an in vitro bovine myocardial model. The acoustic system consisted of HTI-96-min hydrophone, microphone preamplifier, and sound card connected to a laptop computer. The hydrophone has the frequency range of 2 Hz to 30 kHz and nominal sensitivity in the range -240 to -165 dB. The sound was sampled at 96 kHz with 24-bit resolution. Output signal from the hydrophone was fed into the camera audio input to synchronize the video stream. An automated system was developed for the detection and analysis of acoustic events. Nine steam pops were observed. Three distinct sounds were identified as warning signals, each indicating rapid steam formation and its release from tissue. These sounds had a broad frequency range up to 6 kHz with several spectral peaks around 2-3 kHz. Subjectively, these warning signals were perceived as separate loud clicks, a quick succession of clicks, or continuous squeaking noise. Characteristic acoustic signals were identified preceding 80% of pops occurrence. Six cardiologists were able to identify 65% of acoustic signals accurately preceding the pop. An automated system identified the characteristic warning signals in 85% of cases. The mean time from the first acoustic signal to pop occurrence was 46 ± 20 seconds. The automated system had 72.7% sensitivity and 88.9% specificity for predicting pops. Easily identifiable characteristic acoustic emissions
Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael
2017-06-01
Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.
Radiofrequency ablation of osteoid osteoma
Vanderschueren, Geert Maria Joris Michael
2009-01-01
The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency
Agrawal, Nidhi; Smith, Greg; Heffelfinger, Ryan
2014-02-01
Ablative laser resurfacing has evolved as a safe and effective treatment for skin rejuvenation. Although traditional lasers were associated with significant thermal damage and lengthy recovery, advances in laser technology have improved safety profiles and reduced social downtime. CO2 lasers remain the gold standard of treatment, and fractional ablative devices capable of achieving remarkable clinical improvement with fewer side effects and shorter recovery times have made it a more practical option for patients. Although ablative resurfacing has become safer, careful patient selection and choice of suitable laser parameters are essential to minimize complications and optimize outcomes. This article describes the current modalities used in ablative laser skin resurfacing and examines their efficacy, indications, and possible side effects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Directory of Open Access Journals (Sweden)
Michael Praktiknjo
Full Text Available Early information on treatment response of HCC to local ablative therapy is crucial. Elastography as a non-invasive method has recently been shown to play a potential role in distinguishing between benign and malignant liver lesions. Elastography of hepatocellular carcinoma (HCC in early response to local ablative therapy has not been studied to date.We prospectively included a cohort of 14 patients with diagnosis of HCC who were treated with local ablative therapy (transarterial chemoembolization, TACE and/or radiofrequency ablation, RFA. We used 2D shear-wave elastography (RT 2D-SWE to examine stiffness of HCC lesion before and 3, 30 and 90 days after local ablative therapy. Contrast-enhanced imaging after 90 days was performed to evaluate treatment response. Primary endpoint was stiffness of HCC in response to local ablative therapy. Secondary end point was tumor recurrence.Stiffness of HCC nodules and liver showed no significant difference prior to local ablative therapy. As early as three days after treatment, stiffness of responding HCC was significantly higher compared to non-responding. Higher stiffness before treatment was significantly associated with tumor recurrence.Nodule stiffness in general and RT 2D-SWE in particular could provide a useful tool for early prediction of HCC response to local ablative therapy.
Osteoid Osteoma: Experience with Laser- and Radiofrequency-Induced Ablation
International Nuclear Information System (INIS)
Gebauer, Bernhard; Tunn, Per-Ulf; Gaffke, Gunnar; Melcher, Ingo; Felix, Roland; Stroszczynski, Christian
2006-01-01
The purpose of this study was to analyze the clinical outcome of osteoid osteoma treated by thermal ablation after drill opening. A total of 17 patients and 20 procedures were included. All patients had typical clinical features (age, pain) and a typical radiograph showing a nidus. In 5 cases, additional histological specimens were acquired. After drill opening of the osteoid osteoma nidus, 12 thermal ablations were induced by laser interstitial thermal therapy (LITT) (9F Power-Laser-Set; Somatex, Germany) and 8 ablations by radiofrequency ablation (RFA) (RITA; StarBurst, USA). Initial clinical success with pain relief has been achieved in all patients after the first ablation. Three patients had an osteoid osteoma recurrence after 3, 9, and 10 months and were successfully re-treated by thermal ablation. No major complication and one minor complication (sensible defect) were recorded. Thermal ablation is a safe and minimally invasive therapy option for osteoid osteoma. Although the groups are too small for a comparative analysis, we determined no difference between laser- and radiofrequency-induced ablation in clinical outcome after ablation
A 6-year review of the outcome of endometrial ablation.
Tsaltas, J; Taylor, N; Healey, M
1998-02-01
In June, 1995 a postal questionnaire was distributed to all 232 women who had an endometrial ablation at Monash Medical Centre between July, 1989 and December, 1994. Data was analyzed from the 149 who responded. Length of follow-up ranged from 6 months to 6 years 6 months. Of these 78% were satisfied with their ablation and 84% found their menses to be lighter or to have stopped. The repeat ablation rate was 13% and the hysterectomy rate was 17%.
Miller, John M; Kowal, Robert C; Swarup, Vijay; Daubert, James P; Daoud, Emile G; Day, John D; Ellenbogen, Kenneth A; Hummel, John D; Baykaner, Tina; Krummen, David E; Narayan, Sanjiv M; Reddy, Vivek Y; Shivkumar, Kalyanam; Steinberg, Jonathan S; Wheelan, Kevin R
2014-09-01
The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View(TM) ; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145-354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center's first cases. © 2014 Wiley Periodicals, Inc.
Directory of Open Access Journals (Sweden)
Babak. B. Naghshine
2017-02-01
Full Text Available Laser processing is one of the most popular small-scale patterning methods and has many applications in semiconductor device fabrication and biomedical engineering. Numerical modelling of this process can be used for better understanding of the process, optimization, and predicting the quality of the final product. An accurate 3D model is presented here for short laser pulses that can predict the ablation depth and temperature distribution on any section of the material in a minimal amount of time. In this transient model, variations of thermal properties, plasma shielding, and phase change are considered. Ablation depth was measured using a 3D optical profiler. Calculated depths are in good agreement with measured values on laser treated titanium surfaces. The proposed model can be applied to a wide range of materials and laser systems.
Hof, Irene; Chilukuri, Karuna; Arbab-Zadeh, Armin; Scherr, Daniel; Dalal, Darshan; Nazarian, Saman; Henrikson, Charles; Spragg, David; Berger, Ronald; Marine, Joseph; Calkins, Hugh
Introduction: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV)
Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma
Energy Technology Data Exchange (ETDEWEB)
Lassalle, Louis; Campagna, R.; Corcos, G.; Feydy, A. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service de Radiologie Osteo-Articulaire, Paris (France); Babinet, A. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service de Chirurgie Orthopedique, Paris (France); Larousserie, F. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service d' Anatomo-Pathologie, Paris (France); Stephanazzi, J. [Hopital Cochin-APHP Paris Universite Paris Descartes, Service d' Anesthesie, Paris (France)
2017-07-15
To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up. (orig.)
Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma
International Nuclear Information System (INIS)
Lassalle, Louis; Campagna, R.; Corcos, G.; Feydy, A.; Babinet, A.; Larousserie, F.; Stephanazzi, J.
2017-01-01
To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up. (orig.)
Radiofrequency ablation of pulmonary tumors
Energy Technology Data Exchange (ETDEWEB)
Crocetti, Laura, E-mail: l.crocetti@med.unipi.i [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy); Lencioni, Riccardo [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy)
2010-07-15
The development of image-guided percutaneous techniques for local tumor ablation has been one of the major advances in the treatment of solid tumors. Among these methods, radiofrequency (RF) ablation is currently established as the primary ablative modality at most institutions. RF ablation is accepted as the best therapeutic choice for patients with early-stage hepatocellular carcinoma when liver transplantation or surgical resection are not suitable options and is considered as a viable alternate to surgery for inoperable patients with limited hepatic metastatic disease, especially from colorectal cancer. Recently, RF ablation has been demonstrated to be a safe and valuable treatment option for patients with unresectable or medically inoperable lung malignancies. Resection should remain the standard therapy for non-small cell lung cancer (NSCLC) but RF ablation may be better than conventional external-beam radiation for the treatment of the high-risk individual with NSCLC. Initial favourable outcomes encourage combining radiotherapy and RF ablation, especially for treating larger tumors. In the setting of colorectal cancer lung metastases, survival rates provided by RF ablation in selected patients, are substantially higher than those obtained with any chemotherapy regimens and provide indirect evidence that RF ablation therapy improves survival in patients with limited lung metastatic disease.
Hutchinson, Mathew D; Garza, Hyon-He K
2018-02-24
As we have witnessed in other arenas of catheter-based therapeutics, ventricular tachycardia (VT) ablation has become increasingly anatomical in its execution. Multi-modality imaging provides anatomical detail in substrate characterization, which is often complex in nonischemic cardiomyopathy patients. Patients with intramural, intraseptal, and epicardial substrates provide challenges in delivering effective ablation to the critical arrhythmia substrate due to the depth of origin or the presence of adjacent critical structures. Novel ablation techniques such as simultaneous unipolar or bipolar ablation can be useful to achieve greater lesion depth, though at the expense of increasing collateral damage. Disruptive technologies like stereotactic radioablation may provide a tailored approach to these complex patients while minimizing procedural risk. Substrate ablation is a cornerstone of the contemporary VT ablation procedure, and recent data suggest that it is as effective and more efficient that conventional activation guided ablation. A number of specific targets and techniques for substrate ablation have been described, and all have shown a fairly high success in achieving their acute procedural endpoint. Substrate ablation also provides a novel and reproducible procedural endpoint, which may add predictive value for VT recurrence beyond conventional programmed stimulation. Extrapolation of outcome data to nonischemic phenotypes requires caution given both the variability in substrate nonischemic distribution and the underrepresentation of these patients in previous trials.
Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma.
Lassalle, Louis; Campagna, R; Corcos, G; Babinet, A; Larousserie, F; Stephanazzi, J; Feydy, A
2017-07-01
To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up.
Bundle branch block after ablation for Wolff-Parkinson-White syndrome.
Fuenmayor A, Abdel J; Rodríguez S, Yenny A
2013-09-20
Bundle branch block (BBB) is a difficult diagnosis in the Wolff-Parkinson-White syndrome (WPW). We investigated the clinical implications of BBB that appears after performing an accessory pathway (AP) ablation. We studied 199 patients with WPW who were submitted to AP ablation. Thirty (15%) exhibited BBB after the ablation. Twenty-two patients had right BBB and 8 had left BBB. Thirteen patients had right-sided AP and 17 had left-sided AP. They were compared with 82 similar patients without BBB after the AP ablation. Among the patients with BBB, 86.66% showed delays in the middle part of the QRS in the ECG recorded before ablation vs. 18.29% of the patients without BBB (p<0.05) (sensitivity 86%, specificity 81%, positive predictive value 67% and negative predictive value 93%). Forty-four percent of the patients with BBB had BBB morphology during orthodromic tachycardia vs. 10% of the patients without BBB (p<0.05) (sensitivity 44%, specificity 89%, positive predictive value 57% and negative predictive value 82%). No relationship was found between AP location and the site of the BBB. Ejection fraction was normal before (0.61 ± 0.03) and upon completion of follow-up (0.61 ± 0.07). BBB disappeared in 95.3% of the patients. Delays in the middle portion of the QRS may predict BBB after AP ablation. BBB after performing AP ablation is frequent, transient, benign, and not related to either the ablation lesion location or progression to structural heart disease. BBB after AP ablation may be related to cardiac memory. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
McCormick, Zachary L; Korn, Marc; Reddy, Rajiv; Marcolina, Austin; Dayanim, David; Mattie, Ryan; Cushman, Daniel; Bhave, Meghan; McCarthy, Robert J; Khan, Dost; Nagpal, Geeta; Walega, David R
2017-09-01
Determine outcomes of cooled radiofrequency ablation (C-RFA) of the genicular nerves for treatment of chronic knee pain due to osteoarthritis (OA). Cross-sectional survey. Academic pain medicine center. Consecutive patients with knee OA and 50% or greater pain relief following genicular nerve blocks who underwent genicular nerve C-RFA. Survey administration six or more months after C-RFA. Pain numeric rating scale (NRS), Medication Quantification Scale III (MQSIII), Patient Global Impression of Change (PGIC), and total knee arthroplasty (TKA) data were collected. Logistic regression was used to identify factors that predicted treatment success. Thirty-three patients (52 discrete knees) met inclusion criteria. Thirty-five percent (95% confidence interval [CI] = 22-48) of procedures resulted in the combined outcome of 50% or greater reduction in NRS score, reduction of 3.4 or more points in MQSIII score, and PGIC score consistent with "very much improved/improved." Nineteen percent (95% CI = 10-33) of procedures resulted in complete pain relief. Greater duration of pain and greater than 80% pain relief from diagnostic blocks were identified as predictors of treatment success. The accuracy of the model was 0.88 (95% CI = 0.78-0.97, P < 0.001). Genicular C-RFA demonstrated a success rate of 35% based on a robust combination of outcome measures, and 19% of procedures resulted in complete relief of pain at a minimum of six months of follow-up. Report of 80% or greater relief from diagnostic blocks and duration of pain of less than five years are associated with high accuracy in predicting treatment success. Further prospective study is needed to optimize the patient selection protocol and success rate of this procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Energy Technology Data Exchange (ETDEWEB)
Harriss-Phillips, Wendy M., E-mail: wharrphil@gmail.com [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia (Australia); School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia (Australia); Bezak, Eva [School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia (Australia); International Centre for Allied Health Evidence, University of South Australia, Adelaide, South Australia (Australia); Sansom Institute for Health Research, University of South Australia, Adelaide, South Australia (Australia); Potter, Andrew [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide, South Australia (Australia); Adelaide Radiotherapy Centre, Genesis CancerCare, Adelaide, South Australia (Australia)
2016-07-15
Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presented in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of
Predicting outcome of status epilepticus.
Leitinger, M; Kalss, G; Rohracher, A; Pilz, G; Novak, H; Höfler, J; Deak, I; Kuchukhidze, G; Dobesberger, J; Wakonig, A; Trinka, E
2015-08-01
Status epilepticus (SE) is a frequent neurological emergency complicated by high mortality and often poor functional outcome in survivors. The aim of this study was to review available clinical scores to predict outcome. Literature review. PubMed Search terms were "score", "outcome", and "status epilepticus" (April 9th 2015). Publications with abstracts available in English, no other language restrictions, or any restrictions concerning investigated patients were included. Two scores were identified: "Status Epilepticus Severity Score--STESS" and "Epidemiology based Mortality score in SE--EMSE". A comprehensive comparison of test parameters concerning performance, options, and limitations was performed. Epidemiology based Mortality score in SE allows detailed individualization of risk factors and is significantly superior to STESS in a retrospective explorative study. In particular, EMSE is very good at detection of good and bad outcome, whereas STESS detecting bad outcome is limited by a ceiling effect and uncertainty of correct cutoff value. Epidemiology based Mortality score in SE can be adapted to different regions in the world and to advances in medicine, as new data emerge. In addition, we designed a reporting standard for status epilepticus to enhance acquisition and communication of outcome relevant data. A data acquisition sheet used from patient admission in emergency room, from the EEG lab to intensive care unit, is provided for optimized data collection. Status Epilepticus Severity Score is easy to perform and predicts bad outcome, but has a low predictive value for good outcomes. Epidemiology based Mortality score in SE is superior to STESS in predicting good or bad outcome but needs marginally more time to perform. Epidemiology based Mortality score in SE may prove very useful for risk stratification in interventional studies and is recommended for individual outcome prediction. Prospective validation in different cohorts is needed for EMSE, whereas
Radiofrequency ablation of chondroblastoma: long-term clinical and imaging outcomes
Energy Technology Data Exchange (ETDEWEB)
Xie, Cheng; Jeys, Lee [The Royal Orthopaedic Hospital Foundation Trust, Department of Oncology, Birmingham (United Kingdom); James, Steven L.J. [The Royal Orthopaedic Hospital Foundation Trust, Department of Radiology, Birmingham (United Kingdom)
2015-04-01
To investigate the long-term clinical and imaging outcomes of patients with chondroblastoma treated by radiofrequency ablation (RFA). Retrospective analysis of 25 consecutive patients treated with RFA from September 2006 to December 2013. Patients were reviewed within one month of the procedure, then every 3-6 months, and yearly for up to three years. Serial magnetic resonance imaging (MRI) was performed at follow-up to monitor recovery. Functional outcome was assessed using the Musculoskeletal Tumour Society Score (MSTS). Pre-procedure MRI confirmed osteolytic lesions (size range 1.0-3.3 cm; mean 2.0 cm). Patients reported continued symptomatic improvement at four months review. Serial MRI confirmed progressive resolution of inflammation with fatty consolidation of cavity. 88 % of patients became asymptomatic during the follow up period. Three patients' (12 %) symptoms returned at 16, 22 and 24 months respectively after RFA. MRI and biopsy confirmed recurrence in these patients. Functional assessment using MSTS score had an average score of 97.5 %. Mean follow up for the study group was 49 months. RFA is an effective alternative to surgery in the management of chondroblastoma. We recommend a multi-disciplinary approach and RFA should be considered as a first-line treatment. Long-term follow-up is required for timely detection of recurrences. (orig.)
Radiofrequency ablation of chondroblastoma: long-term clinical and imaging outcomes
International Nuclear Information System (INIS)
Xie, Cheng; Jeys, Lee; James, Steven L.J.
2015-01-01
To investigate the long-term clinical and imaging outcomes of patients with chondroblastoma treated by radiofrequency ablation (RFA). Retrospective analysis of 25 consecutive patients treated with RFA from September 2006 to December 2013. Patients were reviewed within one month of the procedure, then every 3-6 months, and yearly for up to three years. Serial magnetic resonance imaging (MRI) was performed at follow-up to monitor recovery. Functional outcome was assessed using the Musculoskeletal Tumour Society Score (MSTS). Pre-procedure MRI confirmed osteolytic lesions (size range 1.0-3.3 cm; mean 2.0 cm). Patients reported continued symptomatic improvement at four months review. Serial MRI confirmed progressive resolution of inflammation with fatty consolidation of cavity. 88 % of patients became asymptomatic during the follow up period. Three patients' (12 %) symptoms returned at 16, 22 and 24 months respectively after RFA. MRI and biopsy confirmed recurrence in these patients. Functional assessment using MSTS score had an average score of 97.5 %. Mean follow up for the study group was 49 months. RFA is an effective alternative to surgery in the management of chondroblastoma. We recommend a multi-disciplinary approach and RFA should be considered as a first-line treatment. Long-term follow-up is required for timely detection of recurrences. (orig.)
Nitta, Hidetoshi; Nakagawa, Shigeki; Kaida, Takayoshi; Arima, Kota; Higashi, Takaaki; Taki, Katsunobu; Okabe, Hirohisa; Hayashi, Hiromitsu; Hashimoto, Daisuke; Chikamoto, Akira; Ishiko, Takatoshi; Beppu, Toru; Baba, Hideo
2017-03-01
We evaluated the therapeutic effect of radiofrequency ablation (RFA) on hepatocellular carcinoma (HCC) according to the number of positive tumor markers. The subjects of this study were 160 patients who underwent percutaneous and surgical RFA for HCC. Patients were divided into negative (n = 51), single- (n = 69), double- (n = 31), and triple-positive (n = 9) tumor marker groups according to the pre-treatment expression of these markers. We looked for any relationships among clinical parameters, outcomes, and tumor markers. The 3-year recurrence-free and overall survival rates of the negative, single-, double-, and triple-positive groups were 30, 19, 16, and 11 % (P = 0.02), and 94, 88, 67, and 37 % (P tumor marker profile was independently associated with local recurrence [hazard ratio (HR) 5.48, 95 % confidence interval (CI) 2.44-12.33, P tumor markers.
Directory of Open Access Journals (Sweden)
Suyash Kulkarni
2017-01-01
Full Text Available Aims: The study was carried out to evaluate the early outcomes using Radiofrequency Ablation (RFA for unresectable liver metastases in the management of metastatic colorectal cancer (mCRC from an area of low endemicity. Material and Methods: 60 Patients with unresectable colorectal liver metastases had undergone 88 sessions of RFA from January 2007 till December 2013. The results were retrospectively analysed to evaluate the outcomes in terms of efficacy and survival rates. Results: The median follow up of patients in our series was 24.8months. 35/52 (67.3% patients had complete response at 3 months while 8 patients were lost to follow up. Of the 17 patients who had recurrence, 4 (23.5% were at the ablated site while 13 patients (76.4% progressed elsewhere. Abdominal pain was commonest post procedural symptom (20%. There was no procedure related mortality or any major complications. Mean disease free interval and Progression free survival was 6.7 and 13.1 months. Estimated median survival in patients with liver limited disease and those with small lesion (3 cm was associated with decreased survival.
The atrial fibrillation ablation pilot study
DEFF Research Database (Denmark)
Arbelo, Elena; Brugada, Josep; Hindricks, Gerhard
2014-01-01
AIMS: The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse...... was achieved in 40.7% of patients (43.7% in paroxysmal AF; 30.2% in persistent AF; 36.7% in long-lasting persistent AF). A second ablation was required in 18% of the cases and 43.4% were under antiarrhythmic treatment. Thirty-three patients (2.5%) suffered an adverse event, 272 (21%) experienced a left atrial...... tachycardia, and 4 patients died (1 haemorrhagic stroke, 1 ventricular fibrillation in a patient with ischaemic heart disease, 1 cancer, and 1 of unknown cause). CONCLUSION: The AFib Ablation Pilot Study provided crucial information on the epidemiology, management, and outcomes of catheter ablation of AFib...
Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara
2018-02-01
To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after
Outcomes of Radiofrequency Ablation for Dysplastic Barrett's Esophagus: A Comprehensive Review
Iabichino, Giuseppe; Arena, Monica; Consolo, Pierluigi; Morace, Carmela; Opocher, Enrico; Mangiavillano, Benedetto
2016-01-01
Barrett's esophagus is a condition in which the normal squamous lining of the esophagus has been replaced by columnar epithelium containing intestinal metaplasia induced by recurrent mucosal injury related to gastroesophageal reflux disease. Barrett's esophagus is a premalignant condition that can progress through a dysplasia-carcinoma sequence to esophageal adenocarcinoma. Multiple endoscopic ablative techniques have been developed with the goal of eradicating Barrett's esophagus and preventing neoplastic progression to esophageal adenocarcinoma. For patients with high-grade dysplasia or intramucosal neoplasia, radiofrequency ablation with or without endoscopic resection for visible lesions is currently the most effective and safe treatment available. Recent data demonstrate that, in patients with Barrett's esophagus and low-grade dysplasia confirmed by a second pathologist, ablative therapy results in a statistically significant reduction in progression to high-grade dysplasia and esophageal adenocarcinoma. Treatment of dysplastic Barrett's esophagus with radiofrequency ablation results in complete eradication of both dysplasia and of intestinal metaplasia in a high proportion of patients with a low incidence of adverse events. A high proportion of treated patients maintain the neosquamous epithelium after successful treatment without recurrence of intestinal metaplasia. Following successful endoscopic treatment, endoscopic surveillance should be continued to detect any recurrent intestinal metaplasia and/or dysplasia. This paper reviews all relevant publications on the endoscopic management of Barrett's esophagus using radiofrequency ablation. PMID:28070182
Directory of Open Access Journals (Sweden)
Martin Reinhardt
2017-12-01
Discussion: This unique multicenter clinical trial aims at the clinical integration of a dedicated software solution to accurately predict lesion size and shape after radiofrequency ablation of liver tumors. Accelerated and optimized workflow integration, and real-time intraoperative image processing, as well as inclusion of patient specific information, e.g. organ perfusion and registration of the real RFA needle position might make the introduced software a powerful tool for interventional radiologists to optimize patient outcomes.
Laredo, Mikaël; Frank, Robert; Waintraub, Xavier; Gandjbakhch, Estelle; Iserin, Laurence; Hascoët, Sebastien; Himbert, Caroline; Gallais, Yves; Hidden-Lucet, Françoise; Duthoit, Guillaume
2017-05-01
Monomorphic ventricular tachycardia (MVT) is common in adults with repaired tetralogy of Fallot (TOF), and is associated with sudden cardiac death. Management of MVT is not defined, and results of catheter ablation (CA) are limited. To evaluate long-term outcomes of MVT CA in repaired TOF. Thirty-four patients (mean age 32±10.3 years; 59% male) with repaired TOF underwent CA for symptomatic MVT between 1990 and 2012 in our centre; direct-current ablation (DCA) was used in 6%, radiofrequency followed by DCA in 29% and radiofrequency alone in 65%. Right ventricular (RV) dysfunction was present in 35% and left ventricular (LV) dysfunction in 21%. Mean numbers of clinical and induced MVTs were 1 and 2, respectively. Mean VT rate was 225±95bpm. Ablation targeted a single site (range 1-2), which was RV outflow tract in 85%. Primary success, defined as ventricular tachycardia (VT) termination during CA and final non-inducibility, was obtained in 82%. Seven patients (21%) required redo ablation in the first 3 months (before 2004; DCA). No death related to CA occurred. Mean follow-up time was 9.5±5.2 years. Antiarrhythmic therapy was discontinued in 71%. There were two cases of sudden cardiac death and four VT recurrences. Freedom from death and arrhythmia recurrence was 94% at 5 years, 81% at 10 years and 70% at 20 years. Global survival was 91% at 20 years. Baseline LV ejection fraction<60% was significantly associated with ventricular arrhythmia recurrence (hazard ratio 16.4, 95% confidence interval 1.8-147; P=0.01). CA can safely address macroreentrant MVT in repaired TOF patients with an acceptable long-term rate of recurrence in this high-risk population. Anatomical classification of isthmuses with electroanatomical mapping provides reproducible endpoints for CA. Attention should be given to LV systolic function in risk assessment and selection of candidates for implantable cardioverter-defibrillator. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan [Eberhard Karls University of Tuebingen, Department on Diagnostic and Interventional Radiology, Tuebingen (Germany); Roland, Joerg; Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany); Pereira, Philippe L. [Clinic for radiology, Nuclear Medicine and Minimal Invasive Therapies, SLK-Clinics, Heilbronn (Germany)
2012-05-15
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 {+-} 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)
International Nuclear Information System (INIS)
Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan; Roland, Joerg; Kickhefel, Antje; Pereira, Philippe L.
2012-01-01
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 ± 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)
Wongcharoen, Wanwarang; Lin, Yenn-Jiang; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Chung, Fa-Po; Chong, Eric; Chao, Tze-Fan; Tuan, Ta-Chuan; Chang, Yao-Ting; Lin, Chin-Yu; Liao, Jo-Nan; Lin, Yi-Chun; Chen, Yun-Yu; Chen, Shih-Ann
2015-09-01
Hyperthyroidism is a known reversible cause of atrial fibrillation (AF). However, some patients remain in AF despite restoration of euthyroid status. The purpose of this study was to compare the electrophysiologic characteristics and long-term ablation outcome in AF patients with and without history of hyperthyroidism. The study enrolled 717 consecutive patients with AF who underwent first AF ablation, which involved pulmonary vein (PV) isolation in paroxysmal AF and additional substrate modification in nonparoxysmal AF patients. Eighty-four patients (12%) with hyperthyroidism history were compared to those without. Euthyroid status was achieved for ≥3 months before ablation in hyperthyroid patients. Patients with hyperthyroid history were associated with older age, more female gender, lower mean right atrial voltage, higher number of PV ectopic foci (1.3 ± 0.4 vs 1.0 ± 0.2, P hyperthyroid patients (7.1% vs 1.6%, P hyperthyroidism was an independent predictor of AF recurrence after single procedure (hazard ratio 2.07, 95% confidence interval 1.27-3.38). AF recurrence rates after multiple procedures were not different between patients with and those without hyperthyroid history. Patients with hyperthyroid history had a significantly higher number of PV ectopies and higher prevalence of non-PV ectopic foci compared to euthyroid patients, which resulted in a higher AF recurrence rate after a single procedure. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Convergent ablation measurements of plastic ablators in gas-filled rugby hohlraums on OMEGA
Casner, A.; Jalinaud, T.; Masse, L.; Galmiche, D.
2015-10-01
Indirect-drive implosions experiments were conducted on the Omega Laser Facility to test the performance of uniformly doped plastic ablators for Inertial Confinement Fusion. The first convergent ablation measurements in gas-filled rugby hohlraums are reported. Ignition relevant limb velocities in the range from 150 to 300 μm .n s-1 have been reached by varying the laser drive energy and the initial capsule aspect ratio. The measured capsule trajectory and implosion velocity are in good agreement with 2D integrated simulations and a zero-dimensional modeling of the implosions. We demonstrate experimentally the scaling law for the maximum implosion velocity predicted by the improved rocket model [Y. Saillard, Nucl. Fusion 46, 1017 (2006)] in the high-ablation regime case.
Gianni, Carola; Mohanty, Sanghamitra; Di Biase, Luigi; Metz, Tamara; Trivedi, Chintan; Gökoğlan, Yalçın; Güneş, Mahmut F; Bai, Rong; Al-Ahmad, Amin; Burkhardt, J David; Gallinghouse, G Joseph; Horton, Rodney P; Hranitzky, Patrick M; Sanchez, Javier E; Halbfaß, Phillipp; Müller, Patrick; Schade, Anja; Deneke, Thomas; Tomassoni, Gery F; Natale, Andrea
2016-04-01
Focal impulse and rotor modulation (FIRM)-guided ablation targets sites that are thought to sustain atrial fibrillation (AF). The purpose of this study was to evaluate the acute and mid-term outcomes of FIRM-guided only ablation in patients with nonparoxysmal AF. We prospectively enrolled patients with persistent and long-standing persistent (LSP) AF at three centers to undergo FIRM-guided only ablation. We evaluated acute procedural success (defined as AF termination, organization, or ≥10% slowing), safety (incidence of periprocedural complications), and long-term success (single-procedure freedom from atrial tachycardia [AT]/AF off antiarrhythmic drugs [AAD] after a 2-month blanking period). Twenty-nine patients with persistent (N = 20) and LSP (N = 9) AF underwent FIRM mapping. Rotors were presents in all patients, with a mean of 4 ± 1.2 per patient (62% were left atrial); 1 focal impulse was identified. All sources were successfully ablated, and overall acute success rate was 41% (0 AF termination, 2 AF slowing, 10 AF organization). There were no major procedure-related adverse events. After a mean 5.7 months of follow-up, single-procedure freedom from AT/AF without AADs was 17%. In nonparoxysmal AF patients, targeted ablation of FIRM-identified rotors is not effective in obtaining AF termination, organization, or slowing during the procedure. After mid-term follow-up, the strategy of ablating FIRM-identified rotors alone did not prevent recurrence from AT/AF. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D
2017-01-01
Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468
Kinetic depletion model for pellet ablation
International Nuclear Information System (INIS)
Kuteev, Boris V.
2001-11-01
A kinetic model for depletion effect, which determines pellet ablation when the pellet passes a rational magnetic surface, is formulated. The model predicts a moderate decrease of the ablation rate compared with the earlier considered monoenergy versions [1, 2]. For typical T-10 conditions the ablation rate reduces by a reactor of 2.5 when the 1-mm pellet penetrates through the plasma center. A substantial deceleration of pellets -about 15% per centimeter of low shire rational q region; is predicted. Penetration for Low Field Side and High Field Side injections is considered taking into account modification of the electron distribution function by toroidal magnetic field. It is shown that Shafranov shift and toroidal effects yield the penetration length for HFS injection higher by a factor of 1.5. This fact should be taken into account when plasma-shielding effects on penetration are considered. (author)
Laboratory Simulations of Micrometeoroid Ablation
Thomas, Evan Williamson
Each day, several tons of meteoric material enters Earth's atmosphere, the majority of which consist of small dust particles (micrometeoroids) that completely ablate at high altitudes. The dust input has been suggested to play a role in a variety of phenomena including: layers of metal atoms and ions, nucleation of noctilucent clouds, effects on stratospheric aerosols and ozone chemistry, and the fertilization of the ocean with bio-available iron. Furthermore, a correct understanding of the dust input to the Earth provides constraints on inner solar system dust models. Various methods are used to measure the dust input to the Earth including satellite detectors, radar, lidar, rocket-borne detectors, ice core and deep-sea sediment analysis. However, the best way to interpret each of these measurements is uncertain, which leads to large uncertainties in the total dust input. To better understand the ablation process, and thereby reduce uncertainties in micrometeoroid ablation measurements, a facility has been developed to simulate the ablation of micrometeoroids in laboratory conditions. An electrostatic dust accelerator is used to accelerate iron particles to relevant meteoric velocities (10-70 km/s). The particles are then introduced into a chamber pressurized with a target gas, and they partially or completely ablate over a short distance. An array of diagnostics then measure, with timing and spatial resolution, the charge and light that is generated in the ablation process. In this thesis, we present results from the newly developed ablation facility. The ionization coefficient, an important parameter for interpreting meteor radar measurements, is measured for various target gases. Furthermore, experimental ablation measurements are compared to predictions from commonly used ablation models. In light of these measurements, implications to the broader context of meteor ablation are discussed.
Gill, Kanwar Rupinder S.; Gross, Seth A.; Greenwald, Bruce D.; Hemminger, Lois L.; Wolfsen, Herbert C.
2009-06-01
Background: There are few data available comparing endoscopic ablation methods for Barrett's esophagus with high-grade dysplasia (BE-HGD). Objective: To determine differences in symptoms and complications associated with endoscopic ablation. Design: Prospective observational study. Setting: Two tertiary care centers in USA. Patients: Consecutive patients with BE-HGD Interventions: In this pilot study, symptoms profile data were collected for BE-HGD patients among 3 endoscopic ablation methods: porfimer sodium photodynamic therapy, radiofrequency ablation and low-pressure liquid nitrogen spray cryotherapy. Main Outcome Measurements: Symptom profiles and complications from the procedures were assessed 1-8 weeks after treatment. Results: Ten BE-HGD patients were treated with each ablation modality (30 patients total; 25 men, median age: 69 years (range 53-81). All procedures were performed in the clinic setting and none required subsequent hospitalization. The most common symptoms among all therapies were chest pain, dysphagia and odynophagia. More patients (n=8) in the porfimer sodium photodynamic therapy group reported weight loss compared to radio-frequency ablactation (n=2) and cryotherapy (n=0). Four patients in the porfimer sodium photodynamic therapy group developed phototoxicity requiring medical treatment. Strictures, each requiring a single dilation, were found in radiofrequency ablactation (n=1) and porfimer sodium photodynamic therapy (n=2) patients. Limitations: Small sample size, non-randomized study. Conclusions: These three endoscopic therapies are associated with different types and severity of post-ablation symptoms and complications.
Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium
S. Iskander-Rizk (Sophinese); P. Kruizinga (Pieter); A.F.W. van der Steen (Ton); G. van Soest (Gijs)
2018-01-01
textabstractCatheter-based radiofrequency ablation for atrial fibrillation has long-term success in 60-70% of cases. A better assessment of lesion quality, depth, and continuity could improve the procedure’s outcome. We investigate here photoacoustic contrast between ablated and healthy atrial-wall
Image-guided radiofrequency ablation of renal cell carcinoma
International Nuclear Information System (INIS)
Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz
2007-01-01
The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)
International Nuclear Information System (INIS)
Okamoto, Mitsunori; Sueda, Takashi; Hashimoto, Masaki; Fukuda, Yukihiro; Iwamoto, Akimichi; Matsumoto, Takeshi; Shintani, Yumiko; Iwasaki, Toshitaka; Kinoshita, Hiroki
2009-01-01
The aim of this study was to assess short and middle term outcome of radiofrequency catheter ablation for drug-refractory paroxysmal and sustained atrial fibrillation. Subjects were 30 patients of atrial fibrillation (19 paroxysmal, 11 sustained) who underwent extensive pulmonary vein isolation from January 2007 to August 2009 in our department. Twenty three men and seven women, aged from 44 to 76 years, were enrolled. Follow-up period was one to 32 months. Drug free success was 33%, but symptoms and electrocardiogram (EGG) findings were improved in 93 % of the patients by administration of anti-arrhythmic agents. Five of the six patients with bradycardia-tachycardia syndrome was free from pacemaker implantation. Left ventricular ejection fraction was improved in two patients with dilated cardiomyopathy (DCM)-like left ventricular dysfunction. One case had cardiac tamponade and transient ST elevation due to right coronary air embolism were observed in two cases. There were no death and no cerebrovascular events during the procedures and follow-up periods. In conclusion, radiofrequency catheter ablation for paroxysmal and sustained atrial fibrillation in our department may be highly acceptable new method for improving the symptoms and clinical signs of the patients. (author)
Direct His bundle pacing post AVN ablation.
Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar
2009-08-01
Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.
Persistent Atrial Fibrillation Ablation in Females: Insight from the MAGIC-AF Trial.
Singh, Sheldon M; D'Avila, Andre; Aryana, Arash; Kim, Young-Hoon; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Heist, E Kevin; Barrett, Conor D; Thorpe, Kevin E; Reddy, Vivek Y
2016-07-27
Atrial fibrillation (AF) ablation is less frequently performed in women when compared to men. There are conflicting data on the safety and efficacy of AF ablation in women. The objective of this study was to compare the clinical characteristics and outcomes in a contemporary cohort of men and women undergoing persistent AF ablation procedures. A total of 182 men and 53 women undergoing a first-ever persistent AF catheter ablation procedure in The Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF) trial were evaluated. Clinical and procedural characteristics were compared between each gender. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Women undergoing catheter ablation procedures were older than men (P Single procedure drug-free atrial arrhythmia recurrence occurred in 53% of the cohort with no difference based on gender (men = 54%, women = 53%; P = 1.0). Procedural (P = 0.04), fluoroscopic (P = 0.02), and ablation times (P = 0.003) were shorter in women compared to men. Periprocedural complications and postablation improvement in quality of life were similar between men and women. Women undergoing a first-ever persistent AF ablation procedure were older but had similar clinical outcomes and complications when compared with men. © 2016 Wiley Periodicals, Inc.
Development of laser ablation plasma by anisotropic self-radiation
Directory of Open Access Journals (Sweden)
Ohnishi Naofumi
2013-11-01
Full Text Available We have proposed a method for reproducing an accurate solution of low-density ablation plasma by properly treating anisotropic radiation. Monte-Carlo method is employed for estimating Eddington tensor with limited number of photon samples in each fluid time step. Radiation field from ablation plasma is significantly affected by the anisotropic Eddington tensor. Electron temperature around the ablation surface changes with the radiation field and is responsible for the observed emission. An accurate prediction of the light emission from the laser ablation plasma requires a careful estimation of the anisotropic radiation field.
Chang, Nan; Lu, Shukuan; Qin, Dui; Xu, Tianqi; Han, Meng; Wang, Supin; Wan, Mingxi
2018-07-01
A HIFU sequence with extremely short pulse duration and high pulse repetition frequency can achieve thermal ablation at a low acoustic power using inertial cavitation. Because of its cavitation-dependent property, the therapeutic outcome is unreliable when the treatment zone lacks cavitation nuclei. To overcome this intrinsic limitation, we introduced perfluorocarbon nanodroplets as extra cavitation nuclei into short-pulsed HIFU-mediated thermal ablation. Two types of nanodroplets were used with perfluorohexane (PFH) as the core material coated with bovine serum albumin (BSA) or an anionic fluorosurfactant (FS) to demonstrate the feasibility of this study. The thermal ablation process was recorded by high-speed photography. The inertial cavitation activity during the ablation was revealed by sonoluminescence (SL). The high-speed photography results show that the thermal ablation volume increased by ∼643% and 596% with BSA-PFH and FS-PFH, respectively, than the short-pulsed HIFU alone at an acoustic power of 19.5 W. Using nanodroplets, much larger ablation volumes were created even at a much lower acoustic power. Meanwhile, the treatment time for ablating a desired volume significantly reduced in the presence of nanodroplets. Moreover, by adjusting the treatment time, lesion migration towards the HIFU transducer could also be avoided. The SL results show that the thermal lesion shape was significantly dependent on the inertial cavitation in this short-pulsed HIFU-mediated thermal ablation. The inertial cavitation activity became more predictable by using nanodroplets. Therefore, the introduction of PFH nanodroplets as extra cavitation nuclei made the short-pulsed HIFU thermal ablation more efficient by increasing the ablation volume and speed, and more controllable by reducing the acoustic power and preventing lesion migration. Copyright © 2018. Published by Elsevier B.V.
Pellet ablation and ablation model development
International Nuclear Information System (INIS)
Houlberg, W.A.
1989-01-01
A broad survey of pellet ablation is given, based primarily on information presented at this meeting. The implications of various experimental observations for ablation theory are derived from qualitative arguments of the physics involved. The major elements of a more complete ablation theory are then outlined in terms of these observations. This is followed by a few suggestions on improving the connections between theory and experimental results through examination of ablation data. Although this is a rather aggressive undertaking for such a brief (and undoubtedly incomplete) assessment, some of the discussion may help us advance the understanding of pellet ablation. 17 refs
Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu
2017-11-01
Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM). We hypothesized that VT recurrence can be predicted and be related to the all-cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM. A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation. After a mean follow-up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20-32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12-19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00-1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all-cause death. © 2017 Wiley Periodicals, Inc.
Action-outcome learning and prediction shape the window of simultaneity of audiovisual outcomes.
Desantis, Andrea; Haggard, Patrick
2016-08-01
To form a coherent representation of the objects around us, the brain must group the different sensory features composing these objects. Here, we investigated whether actions contribute in this grouping process. In particular, we assessed whether action-outcome learning and prediction contribute to audiovisual temporal binding. Participants were presented with two audiovisual pairs: one pair was triggered by a left action, and the other by a right action. In a later test phase, the audio and visual components of these pairs were presented at different onset times. Participants judged whether they were simultaneous or not. To assess the role of action-outcome prediction on audiovisual simultaneity, each action triggered either the same audiovisual pair as in the learning phase ('predicted' pair), or the pair that had previously been associated with the other action ('unpredicted' pair). We found the time window within which auditory and visual events appeared simultaneous increased for predicted compared to unpredicted pairs. However, no change in audiovisual simultaneity was observed when audiovisual pairs followed visual cues, rather than voluntary actions. This suggests that only action-outcome learning promotes temporal grouping of audio and visual effects. In a second experiment we observed that changes in audiovisual simultaneity do not only depend on our ability to predict what outcomes our actions generate, but also on learning the delay between the action and the multisensory outcome. When participants learned that the delay between action and audiovisual pair was variable, the window of audiovisual simultaneity for predicted pairs increased, relative to a fixed action-outcome pair delay. This suggests that participants learn action-based predictions of audiovisual outcome, and adapt their temporal perception of outcome events based on such predictions. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Jarman, Julian We; Hunter, Tina D; Hussain, Wajid; March, Jamie L; Wong, Tom; Markides, Vias
2017-01-01
We sought to determine from key clinical outcomes whether catheter ablation of atrial fibrillation (AF) is associated with increased survival. Using routinely collected hospital data, ablation patients were matched to two control cohorts using direct and propensity score methodology. Four thousand nine hundred ninety-one ablation patients were matched 1:1 with general AF controls without ablation. Five thousand four hundred seven ablation patients were similarly matched to controls who underwent cardioversion. We examined the rates of ischemic stroke or transient ischemic attack (stroke/TIA), heart failure hospitalization, and death. Matched populations had very similar comorbidity profiles, including nearly identical CHA 2 DS 2 -VASc risk distribution ( p =0.6948 and p =0.8152 vs general AF and cardioversion cohorts). Kaplan-Meier models showed increased survival after ablation for all outcomes compared with both control cohorts ( p vs general AF, p =0.0087 for stroke/TIA, p vs cardioversion). Cox regression models also showed improved survival after ablation for all outcomes compared with the general AF cohort (hazard ratio [HR]=0.4, 95% confidence interval [95% CI]: 0.3-0.6, p stroke/TIA; HR=0.4, 95% CI: 0.2-0.6, p stroke/TIA; HR=0.4, 95% CI: 0.3-0.6, p stroke/TIA, and heart failure compared with a matched general AF population and a matched population who underwent cardioversion. Potential confounding of outcomes was minimized by very tight cohort matching.
Adachi, Toru; Yoshida, Kentaro; Takeyasu, Noriyuki; Masuda, Keita; Sekiguchi, Yukio; Sato, Akira; Tada, Hiroshi; Nogami, Akihiko; Aonuma, Kazutaka
2015-02-01
Septal atrial tachycardia (AT) can occur in patients without structural heart disease and in patients with previous catheter ablation of atrial fibrillation. We aimed to assess septal AT that occurs after open-heart surgery. This study comprised 20 consecutive patients undergoing catheter ablation of macroreentrant AT after open-heart surgery. Relevance to surgical approach, mechanisms, anatomic and electrophysiological characteristics, and outcomes were assessed. Septal AT was identified in 7 patients who had all undergone mitral valve surgery. All septal ATs were localized in the left atrial septum, whereas 10 of 13 nonseptal ATs originated from the right atrium. Patients with left septal AT had a thicker fossa ovalis (median, 4.0; 25th-75th percentile, 3.6-4.2 versus 2.3; 1.6-2.6 mm; P=0.006) and broader area of low voltage (open-heart surgery was characterized by a thicker septum, more scar burden in the septum, and repeated prolongations of the tachycardia cycle length during ablation. Such an arrhythmogenic substrate may interfere with transmural lesion formation by ablation and may account for higher likelihood of recurrence of left septal AT. © 2014 American Heart Association, Inc.
Laser Ablation for Cancer: Past, Present and Future
Schena, Emiliano; Saccomandi, Paola; Fong, Yuman
2017-01-01
Laser ablation (LA) is gaining acceptance for the treatment of tumors as an alternative to surgical resection. This paper reviews the use of lasers for ablative and surgical applications. Also reviewed are solutions aimed at improving LA outcomes: hyperthermal treatment planning tools and thermometric techniques during LA, used to guide the surgeon in the choice and adjustment of the optimal laser settings, and the potential use of nanoparticles to allow biologic selectivity of ablative treatments. Promising technical solutions and a better knowledge of laser-tissue interaction should allow LA to be used in a safe and effective manner as a cancer treatment. PMID:28613248
Laser Ablation for Cancer: Past, Present and Future
Directory of Open Access Journals (Sweden)
Emiliano Schena
2017-06-01
Full Text Available Laser ablation (LA is gaining acceptance for the treatment of tumors as an alternative to surgical resection. This paper reviews the use of lasers for ablative and surgical applications. Also reviewed are solutions aimed at improving LA outcomes: hyperthermal treatment planning tools and thermometric techniques during LA, used to guide the surgeon in the choice and adjustment of the optimal laser settings, and the potential use of nanoparticles to allow biologic selectivity of ablative treatments. Promising technical solutions and a better knowledge of laser-tissue interaction should allow LA to be used in a safe and effective manner as a cancer treatment.
Louie, Alexander V.; van Werkhoven, Erik; Chen, Hanbo; Smit, Egbert F.; Paul, Marinus A.; Widder, Joachim; Groen, Harry J. M.; van den Borne, Ben E. E. M.; De Jaeger, Katrien; Slotman, Ben J.; Senan, Suresh
2015-01-01
We report quality of life and indirect costs from patient reported outcomes from the ROSEL randomized control trial comparing stereotactic ablative radiotherapy (SABR, also known as stereotactic body radiotherapy or SBRT) versus surgical resection for medically operable stage IA non-small cell lung
Learned predictiveness and outcome predictability effects are not simply two sides of the same coin.
Thorwart, Anna; Livesey, Evan J; Wilhelm, Francisco; Liu, Wei; Lachnit, Harald
2017-10-01
The Learned Predictiveness effect refers to the observation that learning about the relationship between a cue and an outcome is influenced by the predictive relevance of the cue for other outcomes. Similarly, the Outcome Predictability effect refers to a recent observation that the previous predictability of an outcome affects learning about this outcome in new situations, too. We hypothesize that both effects may be two manifestations of the same phenomenon and stimuli that have been involved in highly predictive relationships may be learned about faster when they are involved in new relationships regardless of their functional role in predictive learning as cues and outcomes. Four experiments manipulated both the relationships and the function of the stimuli. While we were able to replicate the standard effects, they did not survive a transfer to situations where the functional role of the stimuli changed, that is the outcome of the first phase becomes a cue in the second learning phase or the cue of the first phase becomes the outcome of the second phase. Furthermore, unlike learned predictiveness, there was little indication that the distribution of overt attention in the second phase was influenced by previous predictability. The results suggest that these 2 very similar effects are not manifestations of a more general phenomenon but rather independent from each other. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Ozdemir, Didem; Cuhaci, Fatma N; Ozdemir, Elif; Aydin, Cevdet; Ersoy, Reyhan; Turkolmez, Seyda; Cakir, Bekir
2016-06-01
Surgery and radioactive iodine (RAI) ablation constitute the mainstay of the treatment of differentiated thyroid carcinoma (DTC). In this study, we aimed to evaluate the diagnostic value of postoperative early Tc-99m pertechnetate scanning to detect remnant thyroid tissue and predict ablation success. DTC patients evaluated with postoperative Tc-99m pertechnetate scintigraphy and treated with RAI between January 2007 and December 2014 were recruited. The results of Tc-99m pertechnetate scanning were compared with therapeutic I-131 whole-body scanning (TxWBS) and diagnostic I-131 whole-body scanning (DxWBS) performed 6-9 months after RAI. There were 154 (21.5%) male and 563 (78.5%) female patients, with a mean age of 49.11±12.35 years. Postoperative Tc-99m pertechnetate scanning was positive in 499 patients (69.6%) and negative in 218 (30.4%) patients. There were 673 (93.9%) patients with a positive TxWBS scan and 44 (6.1%) patients with negative TxWBS scan. Considering TxWBS as the standard test, sensitivity, specificity, positive predictive value, and negative predictive value of Tc-99m pertechnetate scanning were 72.2, 70.5, 97.4, and 14.2%, respectively. DxWBS was positive in 57 (9.0%) and negative in 564 (91%) patients. Ablation dose was higher and preablation thyroglobulin was lower in patients with negative DxWBS (P=0.001 and 0.04, respectively). Overall, 171 (92.9%) of 184 patients with negative Tc-99m pertechnetate had negative DxWBS. Postoperative Tc-99m pertechnetate scintigraphy has a high positive predictive value to detect remnant tissue in patients with DTC. Although negative Tc-99m pertechnetate scanning does not indicate removal of all thyroid tissue, it is related to successful ablation in more than 90% of patients.
Non-ablative fractional laser provides long-term improvement of mature burn scars
DEFF Research Database (Denmark)
Taudorf, Elisabeth H; Danielsen, Patricia L; Paulsen, Ida F
2015-01-01
BACKGROUND AND OBJECTIVES: Non-ablative fractional laser-treatment is evolving for burn scars. The objective of this study was to evaluate clinical and histological long-term outcome of 1,540 nm fractional Erbium: Glass laser, targeting superficial, and deep components of mature burn scars....... MATERIALS & METHODS: Side-by-side scar-areas were randomized to untreated control or three monthly non-ablative fractional laser-treatments using superficial and extra-deep handpieces. Patient follow-up were at 1, 3, and 6 months. Primary outcome was improvement in overall scar-appearance on a modified...... of scar-appearance. CONCLUSIONS: Combined superficial and deep non-ablative fractional laser-treatments induce long-term clinical and histological improvement of mature burn scars....
Early Adolescent Affect Predicts Later Life Outcomes.
Kansky, Jessica; Allen, Joseph P; Diener, Ed
2016-07-01
Subjective well-being as a predictor for later behavior and health has highlighted its relationship to health, work performance, and social relationships. However, the majority of such studies neglect the developmental nature of well-being in contributing to important changes across the transition to adulthood. To examine the potential role of subjective well-being as a long-term predictor of critical life outcomes, we examined indicators of positive and negative affect at age 14 as predictors of relationship, adjustment, self-worth, and career outcomes a decade later at ages 23 to 25, controlling for family income and gender. We utilised multi-informant methods including reports from the target participant, close friends, and romantic partners in a demographically diverse community sample of 184 participants. Early adolescent positive affect predicted fewer relationship problems (less self-reported and partner-reported conflict, and greater friendship attachment as rated by close peers) and healthy adjustment to adulthood (lower levels of depression, anxiety, and loneliness). It also predicted positive work functioning (higher levels of career satisfaction and job competence) and increased self-worth. Negative affect did not significantly predict any of these important life outcomes. In addition to predicting desirable mean levels of later outcomes, early positive affect predicted beneficial changes across time in many outcomes. The findings extend early research on the beneficial outcomes of subjective well-being by having an earlier assessment of well-being, including informant reports in measuring a large variety of outcome variables, and by extending the findings to a lower socioeconomic group of a diverse and younger sample. The results highlight the importance of considering positive affect as an important component of subjective well-being distinct from negative affect. © 2016 The International Association of Applied Psychology.
Ablative thermal protection systems
International Nuclear Information System (INIS)
Vaniman, J.; Fisher, R.; Wojciechowski, C.; Dean, W.
1983-01-01
The procedures used to establish the TPS (thermal protection system) design of the SRB (solid rocket booster) element of the Space Shuttle vehicle are discussed. A final evaluation of the adequacy of this design will be made from data obtained from the first five Shuttle flights. Temperature sensors installed at selected locations on the SRB structure covered by the TPS give information as a function of time throughout the flight. Anomalies are to be investigated and computer design thermal models adjusted if required. In addition, the actual TPS ablator material loss is to be measured after each flight and compared with analytically determined losses. The analytical methods of predicting ablator performance are surveyed. 5 references
Self-modified quasi-stationary model for the radiation ablation
International Nuclear Information System (INIS)
Zhang Jun; Pei Wenbing; Gu Peijun; Sui Chengzhi; Chang Tieqiang
1996-01-01
The self-modified quasi-stationary model for radiation ablation has been established based on physical picture of numerical simulations. The objective of the model is to predict quantitatively the scaling laws of various ablation parameters driven by soft-X-ray, such as the dependence of ablation depth, pressure on radiation temperature, energy, pulse width, without resorting to complex computer simulations. The computational results are given for some interesting materials in ICF. Scaling laws obtained are simple and effective in target design and analysis of experimental results
Zhai, Yan; Zhang, Zihan; Wang, Wei; Zheng, Tingping; Zhang, Huili
2018-01-01
Heavy menstrual bleeding is a common problem that can severely affect quality of life. To compare bipolar radiofrequency endometrial ablation and thermal balloon ablation for heavy menstrual bleeding in terms of efficacy and health-related quality of life (HRQoL). Online registries were systematically searched using relevant terms without language restriction from inception to November 24, 2016. Randomized control trials or cohort studies of women with heavy menstrual bleeding comparing the efficacy of two treatments were eligible. Data were extracted. Results were expressed as risk ratios (RRs) or weighted mean differences (WMDs) with 95% confidence intervals (CIs). Six studies involving 901 patients were included. Amenorrhea rate at 12 months was significantly higher after bipolar radiofrequency endometrial ablation than after thermal balloon ablation (RR 2.73, 95% CI 2.00-3.73). However, no difference at 12 months was noted for dysmenorrhea (RR 1.04, 95% CI 0.68-1.58) or treatment failure (RR 0.78, 95% CI 0.38-1.60). The only significant difference for HRQoL outcomes was for change in SAQ pleasure score (12 months: WMD -3.51, 95% CI -5.42 to -1.60). Bipolar radiofrequency endometrial ablation and thermal balloon ablation reduce menstrual loss and improve quality of life. However, bipolar radiofrequency endometrial ablation is more effective in terms of amenorrhea rate and SAQ pleasure. © 2017 International Federation of Gynecology and Obstetrics.
Surgical Ablation of Atrial Fibrillation Using Energy Sources.
Brick, Alexandre Visconti; Braile, Domingo Marcolino
2015-01-01
Surgical ablation, concomitant with other operations, is an option for treatment in patients with chronic atrial fibrillation. The aim of this study is to present a literature review on surgical ablation of atrial fibrillation in patients undergoing cardiac surgery, considering energy sources and return to sinus rhythm. A comprehensive survey was performed in the literature on surgical ablation of atrial fibrillation considering energy sources, sample size, study type, outcome (early and late), and return to sinus rhythm. Analyzing studies with immediate results (n=5), the percentage of return to sinus rhythm ranged from 73% to 96%, while those with long-term results (n=20) (from 12 months on) ranged from 62% to 97.7%. In both of them, there was subsequent clinical improvement of patients who underwent ablation, regardless of the energy source used. Surgical ablation of atrial fibrillation is essential for the treatment of this arrhythmia. With current technology, it may be minimally invasive, making it mandatory to perform a procedure in an attempt to revert to sinus rhythm in patients requiring heart surgery.
Takada, Hitomi; Tsuchiya, Kaoru; Yasui, Yutaka; Nakakuki, Natsuko; Tamaki, Nobuharu; Suzuki, Shoko; Nakanishi, Hiroyuki; Itakura, Jun; Takahashi, Yuka; Kurosaki, Masayuki; Asahina, Yasuhiro; Enomoto, Nobuyuki; Izumi, Namiki
2016-11-01
Radiofrequency ablation (RFA) is considered the most effective treatment for early-stage hepatocellular carcinoma (HCC) patients unsuitable for resection. However, poor outcome after RFA has occasionally been reported worldwide. To predict such an outcome, we investigated imaging findings using contrast-enhanced ultrasonography (CEUS) with Sonazoid and serum tumor markers before RFA. This study included 176 early-stage HCC patients who had initially achieved successful RFA. Patients were examined using CEUS; their levels of alpha-fetoprotein (AFP), Lens culinaris agglutinin-reactive fraction of AFP (AFP-L3), and des-gamma-carboxy prothrombin before RFA were measured. Sonazoid provided parenchyma-specific contrast imaging and facilitated tumor vascular architecture imaging through maximum intensity projection (MIP). Kaplan-Meier analysis examined cumulative rates of local tumor progression, intrasubsegmental recurrence, and survival; factors associated with these were determined with Cox proportional hazards analysis. Local tumor progression (n = 15), intrasubsegmental recurrence (n = 46), and death (n = 18) were observed. Irregular pattern in MIP classification and serum AFP-L3 level (>10%) before RFA were identified as independent risk factors for local tumor progression and intrasubsegmental recurrence. These two factors were independently associated with poor survival after RFA (irregular pattern in MIP: hazard ratio, (HR) = 8.26; 95% confidence interval, (CI) = 2.24-30.3; P = 0.002 and AFP-L3 > 10%: HR = 2.94; 95% CI = 1.09-7.94; P = 0.033). Irregular MIP pattern by CEUS and high level of serum AFP-L3 were independent risk factors for poor outcome after successful RFA. The Patients with these findings should be considered as special high-risk group in early-stage HCC. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Macaques can predict social outcomes from facial expressions.
Waller, Bridget M; Whitehouse, Jamie; Micheletta, Jérôme
2016-09-01
There is widespread acceptance that facial expressions are useful in social interactions, but empirical demonstration of their adaptive function has remained elusive. Here, we investigated whether macaques can use the facial expressions of others to predict the future outcomes of social interaction. Crested macaques (Macaca nigra) were shown an approach between two unknown individuals on a touchscreen and were required to choose between one of two potential social outcomes. The facial expressions of the actors were manipulated in the last frame of the video. One subject reached the experimental stage and accurately predicted different social outcomes depending on which facial expressions the actors displayed. The bared-teeth display (homologue of the human smile) was most strongly associated with predicted friendly outcomes. Contrary to our predictions, screams and threat faces were not associated more with conflict outcomes. Overall, therefore, the presence of any facial expression (compared to neutral) caused the subject to choose friendly outcomes more than negative outcomes. Facial expression in general, therefore, indicated a reduced likelihood of social conflict. The findings dispute traditional theories that view expressions only as indicators of present emotion and instead suggest that expressions form part of complex social interactions where individuals think beyond the present.
Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea
2017-04-01
Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.
Clinical impact of rotor ablation in atrial fibrillation: a systematic review.
Parameswaran, Ramanathan; Voskoboinik, Aleksandr; Gorelik, Alexandra; Lee, Geoffrey; Kistler, Peter M; Sanders, Prashanthan; Kalman, Jonathan M
2018-01-11
Rotor mapping and ablation have gained favour over the recent years as an emerging ablation strategy targeting drivers of atrial fibrillation (AF). Their efficacy, however, has been a topic of great debate with variable outcomes across centres. The aim of this study was to systematically review the recent medical literature to determine the medium-term outcomes of rotor ablation in patients with paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PeAF). A systematic search of the contemporary scientific literature (PubMed and EMBASE) was performed in August 2017. Only studies assessing arrhythmia-free survival from rotor ablation of AF were included. We used the random-effects model to assess the primary outcome of pooled medium-term single-procedure AF-free survival for both PAF and PeAF. Success rates from multiple procedures and complication rates were also examined. We included 11 observational studies (4 PAF and 10 PeAF) with a total of 556 patients (166 PAF and 390 PeAF). Pooled single-procedure freedom from AF was 37.8% [95% confidence interval 5.6-86.3%] at a mean follow-up period of 13.8 ± 1.8 months for PAF and 59.2% (95% CI 41.4-74.9%) at a mean follow-up period of 12.9 ± 6 months for PeAF. There was a marked heterogeneity between studies (I2 = 93.8% for PAF and 88.3% for PeAF). The mean complication rate of rotor ablation among the reported studies was 3.4%. The wide variability in success rate between different centres performing rotor ablations suggests that the optimal ablation strategy, particularly targeting rotors, is unclear. Results from randomized studies are necessary before this technique can be considered as an established clinical tool. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.
Lee, Yu Rim; Park, Soo Young; Kim, Seung Up; Jang, Se Young; Tak, Won Young; Kweon, Young Oh; Kim, Beom Kyung; Park, Jun Yong; Kim, Do Young; Ahn, Sang Hoon; Han, Kwang-Hyub; Hur, Keun
2017-05-01
Liver stiffness (LS) value determined using transient elastography (TE) can be used to assess the degree of liver fibrosis. The study investigated whether TE can predict the recurrence of hepatocellular carcinoma (HCC) after radiofrequency ablation (RFA). This study retrospectively enrolled 228 patients with HCC who received TE and RFA as the first-line treatment for HCC between 2008 and 2015. Cox regression analysis was used to identify independent predictors of HCC recurrence. The median age of the study population (170 men and 58 women) was 61 years. During the study period, HCC recurrence and mortality developed in 125 (54.8%) and 37 (16.2%) patients after RFA, respectively. Liver cirrhosis, platelet count, multiple tumors, and LS value were the independent predictors of HCC recurrence. When the study population was stratified into early (measurement using TE can be a useful predictor of HCC recurrence after RFA. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Radiofrequency ablation of osteoid osteomas: five years experience.
Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis
2011-12-01
The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.
Influence of radiotherapy on node-positive prostate cancer treated with androgen ablation
Energy Technology Data Exchange (ETDEWEB)
Sands, M Elizabeth; Pollack, Alan; Zagars, Gunar K
1995-01-01
Purpose: Patients with node-positive prostate cancer that is regionally localized (T1-4, N1-3, M0) have a relatively poor prognosis when a single-treatment modality such as radical surgery, definitive radiotherapy, or androgen ablation is used. While promising results using radical surgery and androgen ablation have been reported, there are no data to support an analogous approach using local radiotherapy and androgen ablation. In this retrospective review, the outcome after local radiotherapy and early androgen ablation (XRT/HORM) was compared to early androgen ablation alone (HORM). Methods and Materials: Between 1984 and 1992 there were 181 patients treated with HORM and 27 patients treated with XRT/HORM at the University of Texas M. D. Anderson Cancer Center. The nodal status of all patients was established pathologically by lymph node dissection, which was terminated after frozen section confirmation of involvement. In the majority of cases androgen ablation was by orchiectomy. The median dose to the prostate in XRT/HORM group was 66 Gy. The median follow-up was 45 months; 49 months for the HORM group and 25 months for the XRT/HORM group. Results: The distribution of prognostic factors between the HORM and XRT/HORM groups was similar, with the exception of tumor grade. There was a significantly larger proportion of high grade tumors in the HORM group. In terms of actuarial disease outcome, at 4 years the results of patients in the HORM group were significantly worse, including a rising prostate specific antigen (PSA) of 53%, any disease progression of 32%, a rising PSA or disease progression of 55%, and local progression of 22%. None of the patients in the XRT/HORM group failed biochemically or clinically. To determine the impact of grade on these findings, the analyses were repeated, using only those with grade 2 tumors. A similar pattern was evidenced with significantly worse actuarial outcome at 4 years for the HORM group using the endpoints of a rising PSA
Klatte, Tobias; Kroeger, Nils; Zimmermann, Uwe; Burchardt, Martin; Belldegrun, Arie S; Pantuck, Allan J
2014-06-01
Currently, most of renal tumors are small, low grade, with a slow growth rate, a low metastatic potential, and with up to 30 % of these tumors being benign on the final pathology. Moreover, they are often diagnosed in elderly patients with preexisting medical comorbidities in whom the underlying medical conditions may pose a greater risk of death than the small renal mass. Concerns regarding overdiagnosis and overtreatment of patients with indolent small renal tumors have led to an increasing interest in minimally invasive, ablative as an alternative to extirpative interventions for selected patients. To provide an overview about the state of the art in radiofrequency ablation (RFA), high-intensity focused ultrasound, and cryoablation in the clinical management of renal cell carcinoma. A PubMed wide the literature search of was conducted. International consensus panels recommend ablative techniques in patients who are unfit for surgery, who are not considered candidates for or elect against elective surveillance, and who have small renal masses. The most often used techniques are cryoablation and RFA. These ablative techniques offer potentially curative outcomes while conferring several advantages over extirpative surgery, including improved patient procedural tolerance, faster recovery, preservation of renal function, and reduction in the risk of intraoperative and postsurgical complications. While it is likely that outcomes associated with ablative modalities will improve with further advances in technology, their application will expand to more elective indications as longer-term efficacy data become available. Ablative techniques pose a valid treatment option in selected patients.
Chen, Y. K.; Henline, W. D.
1993-01-01
The general boundary conditions including mass and energy balances of chemically equilibrated or nonequilibrated gas adjacent to ablating surfaces have been derived. A computer procedure based on these conditions was developed and interfaced with the Navier-Stokes solver for predictions of the flow field, surface temperature, and surface ablation rates over re-entry space vehicles with ablating Thermal Protection Systems (TPS). The Navier-Stokes solver with general surface thermochemistry boundary conditions can predict more realistic solutions and provide useful information for the design of TPS. A test case with a proposed hypersonic test vehicle configuration and associated free stream conditions was developed. Solutions with various surface boundary conditions were obtained, and the effect of nonequilibrium gas as well as surface chemistry on surface heating and ablation rate were examined. The solutions of the GASP code with complete ablating surface conditions were compared with those of the ASC code. The direction of future work is also discussed.
Lesion size in relation to ablation site during radiofrequency ablation
DEFF Research Database (Denmark)
Petersen, H H; Chen, X; Pietersen, A
1998-01-01
This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was perfor......This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation...... was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly.......61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased...
Directory of Open Access Journals (Sweden)
Kelly Ratheal
2016-01-01
Full Text Available Cardiac ablation is a procedure that uses either radiofrequency or cryothermal energy to destroy cells in the heart to terminate and/or prevent arrhythmias. The indications for cardiac catheter ablation include refractory, symptomatic arrhythmias, with more specific guidelines for atrial fibrillation in particular. The ablation procedure itself involves mapping the arrhythmia and destruction of the aberrant pathway in an effort to permanently prevent the arrhythmia. There are many types of arrhythmias, and they require individualized approaches to ablation based on their innately different electrical pathways. Ablation of arrhythmias, such as Wolff-Parkinson-White syndrome, AV nodal reentrant tachycardia, and atrial-fibrillation, is discussed in this review. Ablation has a high success rate overall and minimal complication rates, leading to improved quality of life in many patients.
Enhanced ablation of small anodes in a carbon nanotube arc discharge
Raitses, Yevgeny; Fetterman, Abraham; Keidar, Michael
2008-11-01
An atmospheric pressure helium arc discharge is used for carbon nanotube synthesis. The arc discharge operates in an anodic mode with the ablating anode made from a graphite material. For such conditions, models predict the electron-repelling (negative) anode sheath. In the present experiments, the anode ablation rate is investigated as a function of the anode diameter. It is found that anomalously high ablation occurs for small anode diameters (Fetterman, Y. Raitses and M. Keidar, Carbon (2008).
International Nuclear Information System (INIS)
Jiang Lan; Tsai, H.-L.
2008-01-01
It remains a big challenge to theoretically predict the material removal mechanism in femtosecond laser ablation. To bypass this unresolved problem, many calculations of femtosecond laser ablation of nonmetals have been based on the free electron density distribution without the actual consideration of the phase change mechanism. However, this widely used key assumption needs further theoretical and experimental confirmation. By combining the plasma model and improved two-temperature model developed by the authors, this study focuses on investigating ablation threshold fluence, depth, and shape during femtosecond laser ablation of dielectrics through nonthermal processes (the Coulomb explosion and electrostatic ablation). The predicted ablation depths and shapes in fused silica, by using (1) the plasma model only and (2) the plasma model plus the two-temperature equation, are both in agreement with published experimental data. The widely used assumptions for threshold fluence, ablation depth, and shape in the plasma model based on free electron density are validated by the comparison study and experimental data
Principles for guiding the ONKALO prediction-outcome studies
International Nuclear Information System (INIS)
Andersson, J.; Hudson, J.A.; Anttila, P.; Koskinen, L.; Pitkaenen, P.; Hautojaervi, A.; Wikstroem, L.
2005-09-01
This document provides the necessary foundation for establishing the strategy for the Prediction-Outcome studies currently being conducted by the ONKALO Modelling Task Force (OMTF) during the construction of the ONKALO ramp. These studies relate to the geology, rock mechanics, hydrogeology and hydrogeochemistry. The purpose of the Prediction-Outcome campaign currently underway in the ONKALO ramp tunnel is to optimize Posiva's ability to predict rock conditions ahead of the excavation face. The aim of the work is: to enhance confidence in ability to predict rock conditions in general - and especially for the repository volumes; (later) testing and verification of repository design rules as it would not be possible to make too many additional boreholes in repository volume; and to support the ongoing construction work and make possible the application of the CEIC method. The document also presents current plans for at what stages of the ONKALO construction predictions and outcome assessments will be made as well as current plans for what properties and impacts will be predicted. These plans will evidently be subject to revision during the course of the work. (orig.)
Combining clinical variables to optimize prediction of antidepressant treatment outcomes.
Iniesta, Raquel; Malki, Karim; Maier, Wolfgang; Rietschel, Marcella; Mors, Ole; Hauser, Joanna; Henigsberg, Neven; Dernovsek, Mojca Zvezdana; Souery, Daniel; Stahl, Daniel; Dobson, Richard; Aitchison, Katherine J; Farmer, Anne; Lewis, Cathryn M; McGuffin, Peter; Uher, Rudolf
2016-07-01
The outcome of treatment with antidepressants varies markedly across people with the same diagnosis. A clinically significant prediction of outcomes could spare the frustration of trial and error approach and improve the outcomes of major depressive disorder through individualized treatment selection. It is likely that a combination of multiple predictors is needed to achieve such prediction. We used elastic net regularized regression to optimize prediction of symptom improvement and remission during treatment with escitalopram or nortriptyline and to identify contributing predictors from a range of demographic and clinical variables in 793 adults with major depressive disorder. A combination of demographic and clinical variables, with strong contributions from symptoms of depressed mood, reduced interest, decreased activity, indecisiveness, pessimism and anxiety significantly predicted treatment outcomes, explaining 5-10% of variance in symptom improvement with escitalopram. Similar combinations of variables predicted remission with area under the curve 0.72, explaining approximately 15% of variance (pseudo R(2)) in who achieves remission, with strong contributions from body mass index, appetite, interest-activity symptom dimension and anxious-somatizing depression subtype. Escitalopram-specific outcome prediction was more accurate than generic outcome prediction, and reached effect sizes that were near or above a previously established benchmark for clinical significance. Outcome prediction on the nortriptyline arm did not significantly differ from chance. These results suggest that easily obtained demographic and clinical variables can predict therapeutic response to escitalopram with clinically meaningful accuracy, suggesting a potential for individualized prescription of this antidepressant drug. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Baykaner, Tina; Lalani, Gautam G; Schricker, Amir; Krummen, David E; Narayan, Sanjiv M
2014-09-01
Atrial fibrillation (AF) is the most common sustained arrhythmia and the most common indication for catheter ablation. However, despite substantial technical advances in mapping and energy delivery, ablation outcomes remain suboptimal. A major limitation to AF ablation is that the areas targeted for ablation are rarely of proven mechanistic importance, in sharp contrast to other arrhythmias in which ablation targets demonstrated mechanisms in each patient. Focal impulse and rotor modulation (FIRM) is a new approach to demonstrate the mechanisms that sustain AF ("substrates") in each patient that can be used to guide ablation then confirm elimination of each mechanism. FIRM mapping reveals that AF is sustained by 2-3 rotors and focal sources, with a greater number in patients with persistent than paroxysmal AF, lying within spatially reproducible 2.2 ± 1.4-cm(2) areas in diverse locations. This temporospatial reproducibility, now confirmed by several groups using various methods, changes the concepts regarding AF-sustaining mechanisms, enabling localized rather than widespread ablation. Mechanistically, the role of rotors and focal sources in sustaining AF has been demonstrated by the acute and chronic success of source (FIRM) ablation alone. Clinically, adding FIRM to conventional ablation substantially improves arrhythmia freedom compared with conventional ablation alone, and ongoing randomized trials are comparing FIRM-ablation with and without conventional ablation to conventional ablation alone. In conclusion, ablation of patient-specific AF-sustaining mechanisms (substrates), as exemplified by FIRM, may be central to substantially improving AF ablation outcomes.
Directory of Open Access Journals (Sweden)
Lei Zhang
Full Text Available The aim of this study was to investigate the therapeutic efficacy of percutaneous radiofrequency (RF ablation versus microwave (MW ablation for hepatocellular carcinoma (HCC measuring ≤ 5 cm in greatest diameter. From January 2006 to December 2006, 78 patients had undergone RF ablation whereas 77 had undergone MW ablation. Complete ablation (CA, local tumour progression (LTP and distant recurrence (DR were compared. The overall survival curves were calculated with the Kaplan-Meier technique and compared with the log-rank test. The CA rate was 83.4% (78/93 for RF ablation and 86.7%(91/105 for MW ablation. The LTP rate was 11.8% (11/93 for RF ablation and 10.5% (11/105 for MW ablation. DR was found in 51 (65.4% in the RF ablation and 62 (80.5% in the MW ablation. There was no significant difference in the 1-, 3-, and 5-year overall survival rates (P = 0.780 and the 1-, 3-, and 5-year disease-free survival rates (P = 0.123 between RF and MW ablation. At subgroup analyses, for patients with tumors ≤ 3.0 cm, there was no significant difference in the 1-, 3-, and 5-year overall survival rates (P = 0.067 and the corresponding disease-free survival rates(P = 0.849. For patients with tumor diameters of 3.1-5.0 cm, the 1-, 3-, and 5-year overall survival rates were 87.1%, 61.3%, and 40.1% for RF ablation and 85.4%, 36.6%, and 22% for MW ablation, with no significant difference (P = 0.068. The corresponding disease-free survival rates were 74.2%, 54.8%, and 45.2% for the RF ablation group and 53.3%, 26.8%, and 17.1% for the MW ablation group. The disease-free survival curve for the RF ablation group was significantly better than that for the MW ablation group (P = 0.018. RF ablation and MW ablation are both effective methods in treating hepatocellular carcinomas, with no significant differences in CA, LTP, DR, and overall survival.
Thermal-mechanical deformation modelling of soft tissues for thermal ablation.
Li, Xin; Zhong, Yongmin; Jazar, Reza; Subic, Aleksandar
2014-01-01
Modeling of thermal-induced mechanical behaviors of soft tissues is of great importance for thermal ablation. This paper presents a method by integrating the heating process with thermal-induced mechanical deformations of soft tissues for simulation and analysis of the thermal ablation process. This method combines bio-heat transfer theories, constitutive elastic material law under thermal loads as well as non-rigid motion dynamics to predict and analyze thermal-mechanical deformations of soft tissues. The 3D governing equations of thermal-mechanical soft tissue deformation are discretized by using the finite difference scheme and are subsequently solved by numerical algorithms. Experimental results show that the proposed method can effectively predict the thermal-induced mechanical behaviors of soft tissues, and can be used for the thermal ablation therapy to effectively control the delivered heat energy for cancer treatment.
Uncertainties in model-based outcome predictions for treatment planning
International Nuclear Information System (INIS)
Deasy, Joseph O.; Chao, K.S. Clifford; Markman, Jerry
2001-01-01
Purpose: Model-based treatment-plan-specific outcome predictions (such as normal tissue complication probability [NTCP] or the relative reduction in salivary function) are typically presented without reference to underlying uncertainties. We provide a method to assess the reliability of treatment-plan-specific dose-volume outcome model predictions. Methods and Materials: A practical method is proposed for evaluating model prediction based on the original input data together with bootstrap-based estimates of parameter uncertainties. The general framework is applicable to continuous variable predictions (e.g., prediction of long-term salivary function) and dichotomous variable predictions (e.g., tumor control probability [TCP] or NTCP). Using bootstrap resampling, a histogram of the likelihood of alternative parameter values is generated. For a given patient and treatment plan we generate a histogram of alternative model results by computing the model predicted outcome for each parameter set in the bootstrap list. Residual uncertainty ('noise') is accounted for by adding a random component to the computed outcome values. The residual noise distribution is estimated from the original fit between model predictions and patient data. Results: The method is demonstrated using a continuous-endpoint model to predict long-term salivary function for head-and-neck cancer patients. Histograms represent the probabilities for the level of posttreatment salivary function based on the input clinical data, the salivary function model, and the three-dimensional dose distribution. For some patients there is significant uncertainty in the prediction of xerostomia, whereas for other patients the predictions are expected to be more reliable. In contrast, TCP and NTCP endpoints are dichotomous, and parameter uncertainties should be folded directly into the estimated probabilities, thereby improving the accuracy of the estimates. Using bootstrap parameter estimates, competing treatment
Gandhidasan, S; Ball, D; Kron, T; Bressel, M; Shaw, M; Chu, J; Chander, S; Wheeler, G; Plumridge, N; Chesson, B; David, S; Siva, S
2018-03-01
Stereotactic ablative body radiotherapy (SABR) is currently used to treat oligometastases, but the optimum dose/fractionation schedule is unknown. In this study, we evaluated outcomes after single fraction SABR in patients with oligometastatic disease. Single institutional retrospective review of patients treated with single fraction SABR for one to three oligometastases between 2010 and 2015. The primary outcome was freedom from widespread disease defined as distant recurrence not amenable to surgery or SABR; or recurrence with four or more metastases. In total, 186 treatments were delivered in 132 patients. The two most common target sites were lung (51%) and bone (40%). The most frequent single fraction prescription dose was 26 Gy (47%). The most common primary malignancy was genitourinary (n = 46 patients). Freedom from widespread disease was 75% at 1 year (95% confidence interval 67-83%) and 52% at 2 years (95% confidence interval 42-63%). Freedom from local progression at 1 year was 90% (95% confidence interval 85-95%) and at 2 years was 84% (95% confidence interval 77-91%). A compression fracture of the lumbar vertebra was the only grade 3+ treatment-related toxicity. Single fraction SABR is associated with a high rate of freedom from widespread disease, favourable local control and low toxicity comparable with historic multi-fraction SABR reports. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Theoretical analyses of the refractive implications of transepithelial PRK ablations.
Arba Mosquera, Samuel; Awwad, Shady T
2013-07-01
To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.
Renal Function Outcomes for Multifocal Renal Neoplasms Managed by Radiofrequency Ablation
Energy Technology Data Exchange (ETDEWEB)
Gupta, Pushpender, E-mail: pugupta@wakehealth.edu; Allen, Brian C., E-mail: bcallen2@wakehealth.edu; Chen, Michael Y., E-mail: mchen@wakehealth.edu; Childs, David D., E-mail: dchilds@wakehealth.edu; Kota, Gopi, E-mail: gkota@wakehealth.edu; Zagoria, Ronald J., E-mail: rzagoria@wakehealth.edu [Wake Forest University School of Medicine, Department of Radiology (United States)
2013-10-15
Purpose: To evaluate renal function changes related to radiofrequency ablation (RFA) for the treatment of multifocal renal neoplasms. Methods: This is an institutional review board-approved, Health Insurance Portability and Accountability Act compliant retrospective study of all patients treated with computed tomography guided RFA for multifocal renal neoplasms at one institution. Fifty-seven subjects, mean age 70 (range 37-88) years, underwent RFA of 169 renal neoplasms (average size 2.0 cm). Subjects had between 2 and 8 (mean 2.96) neoplasms ablated. Estimated glomerular filtration rate (eGFR) was measured before and after RFA. Complications related to RFA were recorded. Results: eGFR decreased on average of 4.4 % per tumor treated and 6.7 % per ablation session (average 1.76 tumors treated per session). For subjects with the largest neoplasm measuring >3 cm, eGFR decreased an average of 14.5 % during the course of their treatment. If the largest neoplasm measured 2-3 cm, eGFR decreased an average of 7.7 %, and if the largest neoplasm measured <2 cm, eGFR decreased an average of 3.8 %. Subjects with reduced baseline renal function were more likely to have a greater decline in eGFR after RFA. There was a minor complication rate of 6.3 % (6 of 96 sessions), none of which required treatment, and a major complication rate of 4.2 % (4 of 96 sessions). Conclusion: RFA for the treatment of multifocal renal neoplasms results in mild decline of renal function.
Radiofrequency thermal ablation of malignant hepatic tumors: post-ablation syndrome
International Nuclear Information System (INIS)
Choi, Jung Bin; Rhim, Hyunchul; Kim, Yongsoo; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Lee, Seung Ro
2000-01-01
To evaluate post-ablation syndrome after radiofrequency thermal ablation of malignant hepatic tumors. Forty-two patients with primary (n=3D29) or secondary (n=3D13) hepatic tumors underwent radiofrequency thermal ablation. A total of 65 nodules ranging in size from 1.1 to 5.0 (mean, 3.1) cm were treated percutaneously using a 50W RF generator with 15G expandable needle electrodes. We retrospectively evaluated the spectrum of post-ablation syndrome including pain, fever (≥3D 38 deg C), nausea, vomiting, right shoulder pain, and chest discomfort according to frequency, intensity and duration, and the findings were correlated with tumor location and number of ablations. We also evaluated changes in pre-/post-ablation serum aminotransferase (ALT/AST) and prothrombin time, and correlated these findings with the number of ablations. Post-ablation syndrome was noted in 29 of 42 patients (69.0%), and most symptoms improved with conservative treatment. The most important of these were abdominal plan (n=3D20, 47.6%), fever (n=3D8, 19.0%), and nausea (n=3D7, 16.7%), and four of 42 (9.5%) patients complained of severe pain. The abdominal pain lasted from 3 hours to 5.5 days (mean; 20.4 hours), the fever from 6 hours to 5 days (mean; 63.0 hours). And the nausea from 1 hours to 4 days (mean; 21.0 hours). Other symptoms were right shoulder pain (n=3D6, 14.3%), chest discomfort (n=3D3, 7.1%), and headache (n=3D3, 7.1%). Seventeen of 20 patients (85%) with abdominal pain had subcapsular tumor of the liver. There was significant correlation between pain, location of the tumor, and a number of ablations. After ablation, ALT/AST was elevated more than two-fold in 52.6%/73.7% of patients, respectively but there was no significant correlation with the number of ablation. Post-ablation syndrome is a frequent and tolerable post-procedural process after radiofrequency thermal ablation. The spectrum of this syndrome provides a useful guideline for the post-ablation management. (author)
Modeling CO2 laser ablation impulse of polymers in vapor and plasma regimes
International Nuclear Information System (INIS)
Sinko, John E.; Phipps, Claude R.
2009-01-01
An improved model for CO 2 laser ablation impulse in polyoxymethylene and similar polymers is presented that describes the transition effects from the onset of vaporization to the plasma regime in a continuous fashion. Several predictions are made for ablation behavior.
Matschek, Janine; Bullinger, Eric; von Haeseler, Friedrich; Skalej, Martin; Findeisen, Rolf
2017-02-01
Radiofrequency ablation is a valuable tool in the treatment of many diseases, especially cancer. However, controlled heating up to apoptosis of the desired target tissue in complex situations, e.g. in the spine, is challenging and requires experienced interventionalists. For such challenging situations a mathematical model of radiofrequency ablation allows to understand, improve and optimise the outcome of the medical therapy. The main contribution of this work is the derivation of a tailored, yet expandable mathematical model, for the simulation, analysis, planning and control of radiofrequency ablation in complex situations. The dynamic model consists of partial differential equations that describe the potential and temperature distribution during intervention. To account for multipolar operation, time-dependent boundary conditions are introduced. Spatially distributed parameters, like tissue conductivity and blood perfusion, allow to describe the complex 3D environment representing diverse involved tissue types in the spine. To identify the key parameters affecting the prediction quality of the model, the influence of the parameters on the temperature distribution is investigated via a sensitivity analysis. Simulations underpin the quality of the derived model and the analysis approach. The proposed modelling and analysis schemes set the basis for intervention planning, state- and parameter estimation, and control. Copyright © 2016. Published by Elsevier Inc.
Energy Technology Data Exchange (ETDEWEB)
Loomis, E. N.; Batha, S. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Braun, D.; Sorce, C.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 95281 (United States)
2011-09-15
Isolated defects on inertial confinement fusion ignition capsules are a concern as defects taller than a few hundred nanometers are calculated to form jets of high-Z material, which enter the main fuel. If this mixing of high-Z material is not controlled, a serious degradation in thermonuclear burn can occur. A path towards controlling the growth of defects on the outer surface of plastic capsules is currently under development, but requires accurate predictions of defect evolution driven by the early time ablative Richtmyer-Meshkov (RM) effect. The chief uncertainty is the Equation of State (EOS) for polystyrene and its effect on ablative RM. We report on measurements of the growth of isolated defects made at the onset of ablative RM oscillations driven by x-ray ablation to differentiate between EOS models used in design calculations. Experiments at the OMEGA laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] used on-axis area backlighting radiography and x-ray framing cameras to determine bump areal densities at discrete times. Bumps 12 and 14 {mu}m tall and 33 {mu}m FWHM were found to grow to 2 x their initial areal density by 3 ns after the start of the drive laser pulse. Shock speed measurements established target conditions resulting from the ablation process. The tabular LEOS 5310 [D. Young and E. Corey, J. Appl. Phys. 78, 3748 (1995)] model shows good agreement with measured shock speeds and bump growth whereas the QEOS model [R. More et al., Phys. Fluids 31, 3059 (1988)] over predicts shock speed and under predicts bump growth by 6x. Differences in ablative RM behavior were also found for x-ray ablation compared to laser ablation, which result in an overestimation (or non-existence) of oscillation frequency for x-ray ablation as predicted by theory.
MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system
Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron
2014-03-01
Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.
Lung Tumor Radiofrequency Ablation: Where Do We Stand?
International Nuclear Information System (INIS)
Baère, Thierry de
2011-01-01
Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3–14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.
Directory of Open Access Journals (Sweden)
Ali H. Hachem
2018-01-01
Full Text Available Background. Pulmonary vein isolation is commonly performed using radiofrequency energy with cryoablation gaining acceptance. We performed a meta-analysis of randomized controlled trials which compared radiofrequency versus cryoablation for patients with atrial fibrillation. Methods. A systematic search strategy identified both published and unpublished articles from inception to November 10, 2016, in multiple databases. The primary outcomes for this meta-analysis were long-term freedom from atrial fibrillation at 12-month follow-up and overall postoperative complication rates. For all included studies, the methodological quality was assessed through the Cochrane Collaboration’s tool for risk of bias. Results. A total of 247 articles were identified with eight being included in this review as they satisfied the prespecified inclusion criteria. Overall, there was no significant difference in freedom from atrial fibrillation at ≥12-month follow-up between those receiving cryoballoon and radiofrequency ablation, respectively (OR = 0.98, CI = 0.67–1.43, I2 = 56%, p=0.90. Additionally, the secondary outcomes of duration of ablation, fluoroscopy time, and ablation time failed to reach significance. Cryoballoon ablation had significantly greater odds of postoperative phrenic nerve injury at 12-month follow-up. Conclusions. Our meta-analysis suggests that cryoballoon ablation provides comparable benefits with regard to freedom from atrial fibrillation at medium-term follow-up, fluoroscopy time, ablation time, operative duration, and overall complication rate in comparison to radiofrequency ablation.
Effect of Non-Equilibrium Surface Thermochemistry in Simulation of Carbon Based Ablators
Chen, Yih-Kanq; Gokcen, Tahir
2012-01-01
This study demonstrates that coupling of a material thermal response code and a flow solver using non-equilibrium gas/surface interaction model provides time-accurate solutions for the multidimensional ablation of carbon based charring ablators. The material thermal response code used in this study is the Two-dimensional Implicit Thermal-response and AblatioN Program (TITAN), which predicts charring material thermal response and shape change on hypersonic space vehicles. Its governing equations include total energy balance, pyrolysis gas mass conservation, and a three-component decomposition model. The flow code solves the reacting Navier-Stokes equations using Data Parallel Line Relaxation (DPLR) method. Loose coupling between the material response and flow codes is performed by solving the surface mass balance in DPLR and the surface energy balance in TITAN. Thus, the material surface recession is predicted by finite-rate gas/surface interaction boundary conditions implemented in DPLR, and the surface temperature and pyrolysis gas injection rate are computed in TITAN. Two sets of nonequilibrium gas/surface interaction chemistry between air and the carbon surface developed by Park and Zhluktov, respectively, are studied. Coupled fluid-material response analyses of stagnation tests conducted in NASA Ames Research Center arc-jet facilities are considered. The ablating material used in these arc-jet tests was Phenolic Impregnated Carbon Ablator (PICA). Computational predictions of in-depth material thermal response and surface recession are compared with the experimental measurements for stagnation cold wall heat flux ranging from 107 to 1100 Watts per square centimeter.
Outcome Prediction after Radiotherapy with Medical Big Data.
Magome, Taiki
2016-01-01
Data science is becoming more important in many fields. In medical physics field, we are facing huge data every day. Treatment outcomes after radiation therapy are determined by complex interactions between clinical, biological, and dosimetrical factors. A key concept of recent radiation oncology research is to predict the outcome based on medical big data for personalized medicine. Here, some reports, which are analyzing medical databases with machine learning techniques, were reviewed and feasibility of outcome prediction after radiation therapy was discussed. In addition, some strategies for saving manual labors to analyze huge data in medical physics were discussed.
Long-term outcome of posterior urethral valves ablation using the ...
African Journals Online (AJOL)
Les problemes remarqués au cours d'examens de contrôles a long terme sont: infections urinaire périodique en 35% des cas, insuffisance rénale aigue et chronique en 5% et 15% respectivement, rachitisme, anémie, sousalimentation et rétrécissement urétral. Conclusion: Les enfants qui ont subi une ablation des valves ...
RFA Guardian: Comprehensive Simulation of Radiofrequency Ablation Treatment of Liver Tumors.
Voglreiter, Philip; Mariappan, Panchatcharam; Pollari, Mika; Flanagan, Ronan; Blanco Sequeiros, Roberto; Portugaller, Rupert Horst; Fütterer, Jurgen; Schmalstieg, Dieter; Kolesnik, Marina; Moche, Michael
2018-01-15
The RFA Guardian is a comprehensive application for high-performance patient-specific simulation of radiofrequency ablation of liver tumors. We address a wide range of usage scenarios. These include pre-interventional planning, sampling of the parameter space for uncertainty estimation, treatment evaluation and, in the worst case, failure analysis. The RFA Guardian is the first of its kind that exhibits sufficient performance for simulating treatment outcomes during the intervention. We achieve this by combining a large number of high-performance image processing, biomechanical simulation and visualization techniques into a generalized technical workflow. Further, we wrap the feature set into a single, integrated application, which exploits all available resources of standard consumer hardware, including massively parallel computing on graphics processing units. This allows us to predict or reproduce treatment outcomes on a single personal computer with high computational performance and high accuracy. The resulting low demand for infrastructure enables easy and cost-efficient integration into the clinical routine. We present a number of evaluation cases from the clinical practice where users performed the whole technical workflow from patient-specific modeling to final validation and highlight the opportunities arising from our fast, accurate prediction techniques.
International Nuclear Information System (INIS)
Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Park, Hee Sun; Hur, Hurn; Choi, Byung Ihn; Shin, Kyung Sook
2004-01-01
We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (ρ 3 in group A; 12.4 ± 3.8 cm 3 in group B; 80.9 ± 9.9 cm 3 in group C; 45.3 ± 11.3 cm 3 in group D and 81.6 ± 8.6 cm 3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (ρ < 0.05): 53 ± 12 .deg. C in group A, 42 ± 2 .deg. C in group B, 93 ± 8 .deg. C in group C; 79 ± 12 .deg. C in group D and 83 ± 8 .deg.C in group E. Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with
Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients
International Nuclear Information System (INIS)
Memarsadeghi, Mazda; Schmook, Theresia; Remzi, Mesut; Weber, Michael; Poetscher, Gerda; Lammer, Johannes; Kettenbach, Joachim
2006-01-01
Purpose: To evaluate the outcome of 16 patients after percutaneous radiofrequency ablation of renal tumors. Materials and methods: Sixteen patients (nine women, seven men; mean age, 61 ± 9 years) with 24 unresectable renal tumors (mean volume, 4.3 ± 4.3 cm 3 ) underwent CT-guided (n = 20) or MR imaging-guided (n = 4) percutaneous radiofrequency ablation using an expandable electrode (Starburst XL TM , RITA Medical Systems, Mountain View, CA) with a 150-W generator. The initial follow-up imaging was performed within 1-30 days after RF ablation, then at 3-6 month intervals using either CT or MRI. Residual tumor volume and coagulation necrosis was assessed, and statistical correlation tests were obtained to determine the strength of the relationship between necrosis volume and number of ablations. Results: Overall, 97 overlapping RF ablations were performed (mean, 3.5 ± 1.5 ablations per tumor) during 24 sessions. Five or more RF ablations per tumor created significant larger necrosis volumes than 1-2 (p .034) or 3-4 ablations (p = .020). A complete ablation was achieved in 20/24 tumors (primary technical success, 83%; mean volume of coagulation necrosis: 10.2 ± 7.2 cm 3 ). Three of four residual tumors were retreated and showed complete necrosis thereafter. Three major complications (one percuatneous urinary fistula and two ureteral strictures) were observed after RF ablation. No further clinically relevant complications were observed and renal function remained stable. During a mean follow-up of 11.2 months (range, 0.2-31.5), 15/16 patients (94%) were alive. Only one patient had evidence of local recurrent tumor. Conclusion: The midterm results of percutaneous RF ablation for renal tumors are promising and show that RF ablation is well-suited to preserve renal function
Directory of Open Access Journals (Sweden)
Bischoff-Everding C
2016-01-01
Full Text Available Christoph Bischoff-Everding,1 Ruediger Soeder,2 Benno Neukirch3 1HGC GesundheitsConsult GmbH, Duesseldorf, Germany; 2Gynecological Joint Practice, Mainz, Germany; 3Faculty of Health Care, Hochschule Niederrhein – University of Applied Sciences, Krefeld, Germany Objective: To evaluate the economic and clinical benefits of endometrial radiofrequency ablation (RFA compared with other ablation techniques for the treatment of menorrhagia.Methods: Using German health claims data, women meeting defined inclusion criteria for the intervention group (RFA were selected. A comparable control group (other endometrial ablations was established using propensity score matching. These two groups were compared during the quarter of treatment (QoT and a follow-up of 2 years for the following outcomes: costs during QoT and during follow-up, repeated menorrhagia diagnoses during follow-up and necessary retreatments during follow-up. Results: After performing propensity score matching, 50 cases could be allocated to the intervention group, while 38 were identified as control cases. Patients in the RFA group had 5% fewer repeat menorrhagia diagnoses (40% vs 45%; not significant and 5% fewer treatments associated with recurrent menorrhagia (6% vs 11%; not significant than cases in the control group. During the QoT, the RFA group incurred €578 additional costs (€2,068 vs €1,490; ns. However, during follow-up, the control group incurred €1,254 additional costs (€4,561 vs €5,815; ns, with medication, outpatient physician consultations, and hospitals costs being the main cost drivers. However, none of the results were statistically significant. Conclusion: Although RFA was more cost-intensive in the QoT compared with other endometrial ablation techniques, an average total savings of €676 was generated during the follow-up period. While having evidence that RFA is clinically equivalent to other endometrial ablation procedures, we generated indications that
Prognostic factors for the success of thermal balloon ablation in the treatment of menorrhagia
Bongers, M. Y.; Mol, B. W. J.; Brölmann, H. A. M.
2002-01-01
OBJECTIVE: To identify predictive factors that will ensure successful menorrhagia treatment using hot fluid balloon endometrial ablation. METHODS: This is a prospective study on patients referred for menorrhagia and treated with hot fluid thermal balloon ablation. Potential prognostic factors for
Devismes, D.; Cohen, Barbara A.
2014-01-01
In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K-Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some µg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example
Directory of Open Access Journals (Sweden)
Loomis Eric
2013-11-01
Full Text Available Growth of hydrodynamic instabilities at the interfaces of inertial confinement fusion capsules (ICF due to ablator and fuel non-uniformities are a primary concern for the ICF program. Recently, observed jetting and parasitic mix into the fuel were attributed to isolated defects on the outer surface of the capsule. Strategies for mitigation of these defects exist, however, they require reduced uncertainties in Equation of State (EOS models prior to invoking them. In light of this, we have begun a campaign to measure the growth of isolated defects (bumps due to x-ray ablation Richtmyer-Meshkov in plastic ablators to validate these models. Experiments used hohlraums with radiation temperatures near 70 eV driven by 15 beams from the Omega laser (Laboratory for Laser Energetics, University of Rochester, NY, which sent a ∼1.25Mbar shock into a planar CH target placed over one laser entrance hole. Targets consisted of 2-D arrays of quasi-gaussian bumps (10 microns tall, 34 microns FWHM deposited on the surface facing into the hohlraum. On-axis radiography with a saran (Cl Heα − 2.76keV backlighter was used to measure bump evolution prior to shock breakout. Shock speed measurements were also performed to determine target conditions. Simulations using the LEOS 5310 and SESAME 7592 models required the simulated laser power be turned down to 80 and 88%, respectively to match observed shock speeds. Both LEOS 5310 and SESAME 7592 simulations agreed with measured bump areal densities out to 6 ns where ablative RM oscillations were observed in previous laser-driven experiments, but did not occur in the x-ray driven case. The QEOS model, conversely, over predicted shock speeds and under predicted areal density in the bump.
An experimental study of simultaneous ablation with dual probes in radiofrequency thermal ablation
International Nuclear Information System (INIS)
Jang, Il Soo; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Kim, Young Sun; Heo, Jeong Nam
2003-01-01
To determine the differences between sequential ablation with a single probe and simultaneous ablation with dual probes. Using two 14-gauge expandable probes (nine internal prongs with 4-cm deployment), radiofrequency was applied sequentially (n=8) or simultaneously (n=8) to ten ex-vivo cow livers. Before starting ablation, two RF probes with an inter-probe space of 2 cm (n=8) or 3 cm (n=8) were inserted. In the sequential group, switching the connecting cable to an RF generator permitted ablation with the second probe just after ablation with the first probe had finished. In the simultaneous group, single ablation was performed only after connecting the shafts of both RF probes using a connection device. Each ablation lasted 7 minutes at a target temperature of 105-110 .deg. C. The size and shape of the ablated area, and total ablation time were then compared between the two groups. With 2-cm spacing, the group, mean length and overlapping width of ablated lesions were, respectively, 5.20 and 5.05 cm in the sequential group (n=4), and 5.81 and 5.65 cm in the simultaneous group (n=4). With 3-cm spacing, the corresponding figures were 4.99 and 5.60 cm in the sequential group (n=4), and 6.04 and 6.78 cm in the simultaneous group (n=4). With 2-cm spacing, the mean depth of the proximal waist was 0.58 cm in the sequential (group and 0.28 cm in the simultaneous group, while with 3-cm spacing, the corresponding figures were 1.65 and 1.48 cm. In neither group was there a distal waist. Mean total ablation time was 23.4 minutes in the sequential group and 14 minutes in the simultaneous group. In terms of ablation size and ablation time, simultaneous radiofrequency ablation with dual probes is superior to sequential ablation with a single probe. A simultaneous approach will enable an operator to overcome difficulty in probe repositioning during overlapping ablation, resulting in complete ablation with a successful safety margin
Prediction of outcome in patients with low back pain
DEFF Research Database (Denmark)
Kongsted, Alice; Andersen, Cathrine Hedegaard; Mørk Hansen, Martin
2016-01-01
The clinical course of low back pain (LBP) cannot be accurately predicted by existing prediction tools. Therefore clinicians rely largely on their experience and clinical judgement. The objectives of this study were to investigate 1) which patient characteristics were associated with chiropractors...... intensity (0-10) and disability (RMDQ) after 2-weeks, 3-months, and 12-months. The course of LBP in 859 patients was predicted to be short (54%), prolonged (36%), or chronic (7%). Clinicians' expectations were most strongly associated with education, LBP history, radiating pain, and neurological signs......' expectations of outcome from a LBP episode, 2) if clinicians' expectations related to outcome, 3) how accurate clinical predictions were as compared to those of the STarT Back Screening Tool (SBT), and 4) if accuracy was improved by combining clinicians' expectations and the SBT. Outcomes were measured as LBP...
Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases
International Nuclear Information System (INIS)
Koelblinger, Claus; Strauss, Sandra; Gillams, Alice
2014-01-01
PurposeResection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA).MethodsThis is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded.ResultsTwenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival.ConclusionRFA is a safe and effective treatment for patients with small-volume sarcoma metastases
Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases
Energy Technology Data Exchange (ETDEWEB)
Koelblinger, Claus, E-mail: claus.koelblinger@bhs.at [KH Barmherzige Schwestern Ried, Department of Radiology (Austria); Strauss, Sandra, E-mail: s.strauss@ucl.ac.uk [UCL and UCLH, Department of Medical Oncology (United Kingdom); Gillams, Alice, E-mail: alliesorting@gmail.com [The London Clinic, Department of Radiology (United Kingdom)
2013-05-14
PurposeResection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA).MethodsThis is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded.ResultsTwenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival.ConclusionRFA is a safe and effective treatment for patients with small-volume sarcoma metastases.
Ablation mass features in multi-pulses femtosecond laser ablate molybdenum target
Zhao, Dongye; Gierse, Niels; Wegner, Julian; Pretzler, Georg; Oelmann, Jannis; Brezinsek, Sebastijan; Liang, Yunfeng; Neubauer, Olaf; Rasinski, Marcin; Linsmeier, Christian; Ding, Hongbin
2018-03-01
In this study, the ablation mass features related to reflectivity of bulk Molybdenum (Mo) were investigated by a Ti: Sa 6 fs laser pulse at central wavelength 790 nm. The ablated mass removal was determined using Confocal Microscopy (CM) technique. The surface reflectivity was calibrated and measured by a Lambda 950 spectrophotometer as well as a CCD camera during laser ablation. The ablation mass loss per pulse increase with the increasing of laser shots, meanwhile the surface reflectivity decrease. The multi-pulses (100 shots) ablation threshold of Mo was determined to be 0.15 J/cm2. The incubation coefficient was estimated as 0.835. The reflectivity change of the Mo target surface following multi-pulses laser ablation were studied as a function of laser ablation shots at various laser fluences from 1.07 J/cm2 to 36.23 J/cm2. The results of measured reflectivity indicate that surface reflectivity of Mo target has a significant decline in the first 3-laser pulses at the various fluences. These results are important for developing a quantitative analysis model for laser induced ablation and laser induced breakdown spectroscopy for the first wall diagnosis of EAST tokamak.
Directory of Open Access Journals (Sweden)
Ha NH
2015-07-01
Full Text Available Ngoc Hoang Ha, Richard Hummel, David I WatsonDepartment of Surgery, Flinders University, Flinders Medical Centre, Bedford Park, Adelaide, South Australia, AustraliaAbstract: Barrett’s esophagus is the only known precursor lesion for esophageal adenocarcinoma. Previous studies have shown that a variety of methods can be applied to destroy Barrett’s esophagus epithelium, and healing with a new esophageal squamous epithelium usually occurs following ablation. Radiofrequency ablation (RFA is a relatively new endoscopic technique. It has been claimed that ablation using RFA reduces the risk of cancer progression. RFA is usually easy to apply and is associated with a low risk of morbidity. It achieves complete eradication of (non dysplastic Barrett’s esophagus in most individuals, and the risk of progression to higher grades of dysplasia or cancer is reduced after RFA, although not completely eliminated. Limitations include recurrence of Barrett’s esophagus in up to one-third of individuals, a risk of “buried islands” of Barrett’s esophagus remaining below the regenerated mucosa, and uncertainty about the biological behavior of the new squamous epithelium after RFA. Current evidence supports the use of RFA in individuals with high-grade dysplasia in Barrett’s esophagus, and early stage (T1a intramucosal cancer, and select individuals with low-grade dysplasia. As accurate diagnosis of low-grade dysplasia remains difficult outside expert centers, it is probably premature to recommend routine RFA for all patients diagnosed with low-grade dysplasia in the community, despite the favorable outcomes from one randomized trial. Furthermore, long-term outcomes following ablation remain uncertain, and ongoing endoscopy surveillance is still required after RFA as progression to cancer remains a possibility. Outcomes from large studies with long-term follow-up are needed to definitively confirm that RFA ablation can reliably prevent cancer
Design calculations for NIF convergent ablator experiments
Directory of Open Access Journals (Sweden)
Olson R.E.
2013-11-01
Full Text Available The NIF convergent ablation tuning effort is underway. In the early experiments, we have discovered that the design code simulations over-predict the capsule implosion velocity and shock flash ρr, but under-predict the hohlraum x-ray flux measurements. The apparent inconsistency between the x-ray flux and radiography data implies that there are important unexplained aspects of the hohlraum and/or capsule behavior.
Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.
Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R
To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Phrenic Nerve Injury After Catheter Ablation of Atrial Fibrillation
Directory of Open Access Journals (Sweden)
Jacques Clementy
2007-01-01
Full Text Available Phrenic Nerve Injury (PNI has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to the superior vena cava (SVC, and the antero-inferior part of the right superior pulmonary vein (RSPV. In addition, the proximity of the left phrenic nerve to the left atrial appendage has been well established. Independent of the type of ablation catheter (4mm, 8 mm, irrigated tip, balloon or energy source used (radiofrequency (RF, ultrasound, cryothermia, and laser; the risk of PNI exists during ablation at the critical areas listed above. Although up to thirty-one percent of patients with PNI after AF ablation remain asymptomatic, dyspnea remain the cardinal symptom and is present in all symptomatic patients. Despite the theoretical risk for significant adverse effect on functional status and quality of life, short-term outcomes from published studies appear favorable with 81% of patients with PNI having a complete recovery after 7 ± 7 months.Conclusion: Existing studies have described PNI as an uncommon but avoidable complication in patients undergoing pulmonary vein isolation for AF. Prior to ablation at the SVC, antero-inferior RSPV ostium or the left atrial appendage, pacing should be performed before energy delivery. If phrenic nerve capture is documented, energy delivery should be avoided at this site. Electrophysiologist's vigilance as well as pacing prior to ablation at high risk sites in close proximity to the phrenic nerve are the currently available tools to avoid the complication of PNI.
Shigemori, Keisuke; Sakaiya, Tatsuhiko; Otani, Kazuto; Fujioka, Shinsuke; Nakai, Mitsuo; Azechi, Hiroshi; Shiraga, Hiroyuki; Tamari, Yohei; Okuno, Kazuki; Sunahara, Atsushi; Nagatomo, Hideo; Murakami, Masakatsu; Nishihara, Katsunobu; Izawa, Yasukazu
2004-09-01
Hydrodynamic instabilities are key issues of the physics of inertial confinement fusion (ICF) targets. Among the instabilities, Rayleigh-Taylor (RT) instability is the most important because it gives the largest growth factor in the ICF targets. Perturbations on the laser irradiated surface grow exponentially, but the growth rate is reduced by ablation flow. The growth rate γ is written as Takabe-Betti formula: γ = [kg/(1+kL)]1/2-βkm/pa, where k is wave number of the perturbation, g is acceleration, L is density scale-length, β is a coefficient, m is mass ablation rate per unit surface, and ρa is density at the ablation front. We experimentally measured all the parameters in the formula for polystyrene (CH) targets. Experiments were done on the HIPER laser facility at Institute of Laser Engineering, Osaka University. We found that the β value in the formula is ~ 1.7, which is in good agreements with the theoretical prediction, whereas the β for certain perturbation wavelengths are larger than the prediction. This disagreement between the experiment and the theory is mainly due to the deformation of the cutoff surface, which is created by non-uniform ablation flow from the ablation surface. We also found that high-Z doped plastic targets have multiablation structure, which can reduce the RT growth rate. When a low-Z target with high-Z dopant is irradiated by laser, radiation due to the high-Z dopant creates secondary ablation front deep inside the target. Since, the secondary ablation front is ablated by x-rays, the mass ablation rate is larger than the laser-irradiated ablation surface, that is, further reduction of the RT growth is expected. We measured the RT growth rate of Br-doped polystyrene targets. The experimental results indicate that of the CHBr targets show significantly small growth rate, which is very good news for the design of the ICF targets.
Energy Technology Data Exchange (ETDEWEB)
Yoon, Hyuk Jin; Kim, Sung Hoon; O, Joo Hyun; Lee, Yeong Joo; Kim, Hyoung Woo [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Seo, Ye Young [Dept. of Nuclear Medicine, College of Medicine, The Inje University Sanggye Paik Hospital, Seoul (Korea, Republic of); Ryu, Ji Young [Dept. of Radiology, Incheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)
2015-12-15
The aim of this study was to evaluate the value of thyroglobulin (Tg) kinetics during preparation of radioiodine ablation for prediction of initial radioiodine ablation failure in thyroid cancer patients. Thyroid cancer patients after total thyroidectomy who underwent radioiodine ablation with 3–4 weeks of hormone withdrawal between May 2011 and January 2012 were included. Consecutive serum Tg levels 5–10 days before ablation (Tg1) and on the day of ablation (Tg2) were obtained. The difference between Tg1 and Tg2 (ΔTg), daily change rate of Tg (ΔTg/day) and Tg doubling time (Tg-DT) were calculated. Success of initial ablation was determined by the results of the follow-up ultrasonography, diagnostic radioiodine scan and stimulated Tg level after 6 to 20 months. A total of 143 patients were included. Failed ablation was reported in 52 patients. Tg2 higher than 5.6 ng/ml and Tg-DT shorter than 4.2 days were significantly related to a high risk of ablation failure. ΔTg and ΔTg/day did not show significant correlation with ablation failure. Thyroglobulin kinetics on consecutive blood sampling during hormone withdrawal may be helpful in predicting patients with higher risk of treatment failure of initial radioiodine ablation therapy in thyroid cancer patients.
International Nuclear Information System (INIS)
Yoon, Hyuk Jin; Kim, Sung Hoon; O, Joo Hyun; Lee, Yeong Joo; Kim, Hyoung Woo; Seo, Ye Young; Ryu, Ji Young
2015-01-01
The aim of this study was to evaluate the value of thyroglobulin (Tg) kinetics during preparation of radioiodine ablation for prediction of initial radioiodine ablation failure in thyroid cancer patients. Thyroid cancer patients after total thyroidectomy who underwent radioiodine ablation with 3–4 weeks of hormone withdrawal between May 2011 and January 2012 were included. Consecutive serum Tg levels 5–10 days before ablation (Tg1) and on the day of ablation (Tg2) were obtained. The difference between Tg1 and Tg2 (ΔTg), daily change rate of Tg (ΔTg/day) and Tg doubling time (Tg-DT) were calculated. Success of initial ablation was determined by the results of the follow-up ultrasonography, diagnostic radioiodine scan and stimulated Tg level after 6 to 20 months. A total of 143 patients were included. Failed ablation was reported in 52 patients. Tg2 higher than 5.6 ng/ml and Tg-DT shorter than 4.2 days were significantly related to a high risk of ablation failure. ΔTg and ΔTg/day did not show significant correlation with ablation failure. Thyroglobulin kinetics on consecutive blood sampling during hormone withdrawal may be helpful in predicting patients with higher risk of treatment failure of initial radioiodine ablation therapy in thyroid cancer patients
Berber, Eren
2015-07-01
Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. The patients had an average of two tumours (range 1-4), measuring 1.9 ± 0.4 cm (range 0.9-4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5-10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. © 2015 International Hepato-Pancreato-Biliary Association.
Radiofrequency Ablation of Lung Tumors
... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...
International Nuclear Information System (INIS)
Yokokawa, Miki; Koyama, Keiko; Ino, Toshihiko; Naito, Shigeto; Oshima, Shigeru; Taniguchi, Koichi; Tada, Hiroshi
2010-01-01
Inflammatory responses following atrial fibrillation (AF) ablation may aggravate arrhythmogenic activity and cause an early recurrence of AF (ERAF). In 56 patients who underwent circumferential pulmonary vein ablation (CPVA) for paroxysmal AF, cardiovascular magnetic resonance imaging (CMRI) was evaluated in 5 subdivided left atrial (LA) regions before the CPVA and at 1 day and 1 month after. At a mean of 7±10 days after the CPVA, 23 patients (41%) developed 1 or more episodes of AF (ERAF group), while 33 patients (59%) remained free from AF during the first month of follow up (no-ERAF group). LA wall thickness increased 1 day after the CPVA in both groups, as demonstrated by high T2-weighted signal. The LA roof thickness and its increase, however, were greater in the ERAF group than in the no-ERAF group (P<0.05). Regions of delayed enhancement (DE) were also frequently detected in both groups, but the total number of DE regions did not differ between the 2 groups. The thickening of the LA wall associated with a high T2-weighted signal resolved within 1 month. No significant difference between the 2 groups was found in any of the CMRI parameters before or 1 month after CPVA. Thickening of the LA roof shortly after CPVA may predict an ERAF. (author)
Network information improves cancer outcome prediction.
Roy, Janine; Winter, Christof; Isik, Zerrin; Schroeder, Michael
2014-07-01
Disease progression in cancer can vary substantially between patients. Yet, patients often receive the same treatment. Recently, there has been much work on predicting disease progression and patient outcome variables from gene expression in order to personalize treatment options. Despite first diagnostic kits in the market, there are open problems such as the choice of random gene signatures or noisy expression data. One approach to deal with these two problems employs protein-protein interaction networks and ranks genes using the random surfer model of Google's PageRank algorithm. In this work, we created a benchmark dataset collection comprising 25 cancer outcome prediction datasets from literature and systematically evaluated the use of networks and a PageRank derivative, NetRank, for signature identification. We show that the NetRank performs significantly better than classical methods such as fold change or t-test. Despite an order of magnitude difference in network size, a regulatory and protein-protein interaction network perform equally well. Experimental evaluation on cancer outcome prediction in all of the 25 underlying datasets suggests that the network-based methodology identifies highly overlapping signatures over all cancer types, in contrast to classical methods that fail to identify highly common gene sets across the same cancer types. Integration of network information into gene expression analysis allows the identification of more reliable and accurate biomarkers and provides a deeper understanding of processes occurring in cancer development and progression. © The Author 2012. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Energy Technology Data Exchange (ETDEWEB)
Voogt, Marianne J., E-mail: m.voogt@umcutrecht.nl [University Medical Center Utrecht, Department of Radiology (Netherlands); Stralen, Marijn van [University Medical Center Utrecht, Image Sciences Institute (Netherlands); Ikink, Marlijne E. [University Medical Center Utrecht, Department of Radiology (Netherlands); Deckers, Roel; Vincken, Koen L.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute (Netherlands); Mali, Willem P. Th. M.; Bosch, Maurice A. A. J. van den [University Medical Center Utrecht, Department of Radiology (Netherlands)
2012-10-15
Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.
Machine Learning and Neurosurgical Outcome Prediction: A Systematic Review.
Senders, Joeky T; Staples, Patrick C; Karhade, Aditya V; Zaki, Mark M; Gormley, William B; Broekman, Marike L D; Smith, Timothy R; Arnaout, Omar
2018-01-01
Accurate measurement of surgical outcomes is highly desirable to optimize surgical decision-making. An important element of surgical decision making is identification of the patient cohort that will benefit from surgery before the intervention. Machine learning (ML) enables computers to learn from previous data to make accurate predictions on new data. In this systematic review, we evaluate the potential of ML for neurosurgical outcome prediction. A systematic search in the PubMed and Embase databases was performed to identify all potential relevant studies up to January 1, 2017. Thirty studies were identified that evaluated ML algorithms used as prediction models for survival, recurrence, symptom improvement, and adverse events in patients undergoing surgery for epilepsy, brain tumor, spinal lesions, neurovascular disease, movement disorders, traumatic brain injury, and hydrocephalus. Depending on the specific prediction task evaluated and the type of input features included, ML models predicted outcomes after neurosurgery with a median accuracy and area under the receiver operating curve of 94.5% and 0.83, respectively. Compared with logistic regression, ML models performed significantly better and showed a median absolute improvement in accuracy and area under the receiver operating curve of 15% and 0.06, respectively. Some studies also demonstrated a better performance in ML models compared with established prognostic indices and clinical experts. In the research setting, ML has been studied extensively, demonstrating an excellent performance in outcome prediction for a wide range of neurosurgical conditions. However, future studies should investigate how ML can be implemented as a practical tool supporting neurosurgical care. Copyright © 2017 Elsevier Inc. All rights reserved.
Effect of Hashimoto thyroiditis on low-dose radioactive-iodine remnant ablation.
Kwon, Hyungju; Choi, June Young; Moon, Jae Hoon; Park, Hyo Jin; Lee, Won Woo; Lee, Kyu Eun
2016-04-01
Radioactive-iodine remnant ablation is an integral part of the papillary thyroid carcinoma (PTC) treatment. Although a minimum dose is usually recommended, there is controversy as to whether the low-dose (1100 MBq) radioactive-iodine remnant ablation is adequate for selected patients. A retrospective cohort study was conducted on 691 patients. Patients with no remnant thyroid on the follow-up whole body scan and low stimulated thyroglobulin (sTg) level (Hashimoto thyroiditis based on histopathology diagnosis (odds ratio [OR] = 3.23; p Hashimoto thyroiditis and elevated sTg are negative predictive factors for successful low-dose radioactive-iodine remnant ablation treatment. An appropriate risk-adjusted approach may improve the efficacy of radioactive-iodine remnant ablation treatment. © 2015 Wiley Periodicals, Inc. Head Neck 38: E730-E735, 2016. © 2015 Wiley Periodicals, Inc.
Predicting sports betting outcomes
Flis, Borut
2014-01-01
We wish to build a model, which could predict the outcome of basketball games. The goal was to achieve an sufficient enough accuracy to make a profit in sports betting. One learning example is a game in the NBA regular season. Every example has multiple features, which describe the opposing teams. We tried many methods, which return the probability of the home team winning and the probability of the away team winning. These probabilities are used for risk analysis. We used the best model in h...
Comparison of Physician-Predicted to Measured Low Vision Outcomes
Chan, Tiffany L.; Goldstein, Judith E.; Massof, Robert W.
2013-01-01
Purpose To compare low vision rehabilitation (LVR) physicians’ predictions of the probability of success of LVR to patients’ self-reported outcomes after provision of usual outpatient LVR services; and to determine if patients’ traits influence physician ratings. Methods The Activity Inventory (AI), a self-report visual function questionnaire, was administered pre and post-LVR to 316 low vision patients served by 28 LVR centers that participated in a collaborative observational study. The physical component of the Short Form-36, Geriatric Depression Scale, and Telephone Interview for Cognitive Status were also administered pre-LVR to measure physical capability, depression and cognitive status. Following patient evaluation, 38 LVR physicians estimated the probability of outcome success (POS), using their own criteria. The POS ratings and change in functional ability were used to assess the effects of patients’ baseline traits on predicted outcomes. Results A regression analysis with a hierarchical random effects model showed no relationship between LVR physician POS estimates and AI-based outcomes. In another analysis, Kappa statistics were calculated to determine the probability of agreement between POS and AI-based outcomes for different outcome criteria. Across all comparisons, none of the kappa values were significantly different from 0, which indicates the rate of agreement is equivalent to chance. In an exploratory analysis, hierarchical mixed effects regression models show that POS ratings are associated with information about the patient’s cognitive functioning and the combination of visual acuity and functional ability, as opposed to visual acuity or functional ability alone. Conclusions Physicians’ predictions of LVR outcomes appear to be influenced by knowledge of patients’ cognitive functioning and the combination of visual acuity and functional ability - information physicians acquire from the patient’s history and examination. However
Outcome manipulation in corporate prediction markets
DEFF Research Database (Denmark)
Ottaviani, Marco; Sørensen, Peter Norman
2007-01-01
This paper presents a framework for applying prediction markets to corporate decision-making. The analysis is motivated by the recent surge of interest in markets as information aggregation devices and their potential use within firms. We characterize the amount of outcome manipulation that results...
Effect of ablatant composition on the ablation of a fuelling pellet
International Nuclear Information System (INIS)
Chang, C.T.; Thomsen, K.; Piret, S.
1988-01-01
The single species neutral-shielding model for the ablation of a hydrogenic pellet is extended by considering the ablatant as a mixture of four species: molecular and atomic hydrogen, protons and electrons. Compared with the results of the frozen flow, (i.e. the single species molecular hydrogen gas model), results of the analysis showed that the presence of dissociation and ionization effects caused a marked difference of the ablatant state. The attenuations of the incoming electron energy and energy flux, however, are very much similar irrespective of whether the ablated flow is in a frozen or an equilibrium state. The scaling law of the pellet ablation rate with respect to the plasma state of Te, ne and the pellet radius remains the same; the ablation rate is reduced by approximately 15%. To examine the possible existence of a spherical shell around the pellet where most of the incoming electron energy is absorbed, acodmparison is made between the local electron collisional mean free path and the electron Larmor radius. A critical field at the ionization radius is evaluated. An effective spherical energyabsorbing region exists when the local field strength is below the critical value. For a plasma state of low Te and ne, (where the ablatant is hardly ionized), and for one near the thermonuclear condition (where a highly dense ablatant exists near the pellet), the effective energy absorption region is nearly spherical. 20 refs. (author)
Prediction of processing tomato peeling outcomes
Peeling outcomes of processing tomatoes were predicted using multivariate analysis of Magnetic Resonance (MR) images. Tomatoes were obtained from a whole-peel production line. Each fruit was imaged using a 7 Tesla MR system, and a multivariate data set was created from 28 different images. After ...
Predicting outcome of acute kidney transplant rejection using
Rekers, Niels Vincent
2014-01-01
Acute kidney transplant rejection is an important risk factors for adverse graft outcome. Once diagnosed, it remains difficult to predict the risk of graft loss and the response to anti-rejection treatment. The aim of this thesis was to identify biomarkers during acute rejection, which predict the
Laser ablation principles and applications
1994-01-01
Laser Ablation provides a broad picture of the current understanding of laser ablation and its many applications, from the views of key contributors to the field. Discussed are in detail the electronic processes in laser ablation of semiconductors and insulators, the post-ionization of laser-desorbed biomolecules, Fourier-transform mass spectroscopy, the interaction of laser radiation with organic polymers, laser ablation and optical surface damage, laser desorption/ablation with laser detection, and laser ablation of superconducting thin films.
International Nuclear Information System (INIS)
Tanaka, Toshihiro; Westphal, Saskia; Isfort, Peter; Braunschweig, Till; Penzkofer, Tobias; Bruners, Philipp; Kichikawa, Kimihiko; Schmitz-Rode, Thomas; Mahnken, Andreas H.
2012-01-01
Purpose: To compare the effectiveness of microwave (MW) ablation with radiofrequency (RF) ablation for treating breast tissue in a nonperfused ex vivo model of healthy bovine udder tissue. Materials and Methods: MW ablations were performed at power outputs of 25W, 35W, and 45W using a 915-MHz frequency generator and a 2-cm active tip antenna. RF ablations were performed with a bipolar RF system with 2- and 3-cm active tip electrodes. Tissue temperatures were continuously monitored during ablation. Results: The mean short-axis diameters of the coagulation zones were 1.34 ± 0.14, 1.45 ± 0.13, and 1.74 ± 0.11 cm for MW ablation at outputs of 25W, 35W, and 45W. For RF ablation, the corresponding values were 1.16 ± 0.09 and 1.26 ± 0.14 cm with electrodes having 2- and 3-cm active tips, respectively. The mean coagulation volumes were 2.27 ± 0.65, 2.85 ± 0.72, and 4.45 ± 0.47 cm 3 for MW ablation at outputs of 25W, 35W, and 45W and 1.18 ± 0.30 and 2.29 ± 0.55 cm 3 got RF ablation with 2- and 3-cm electrodes, respectively. MW ablations at 35W and 45W achieved significantly longer short-axis diameters than RF ablations (P < 0.05). The highest tissue temperature was achieved with MW ablation at 45W (P < 0.05). On histological examination, the extent of the ablation zone in MW ablations was less affected by tissue heterogeneity than that in RF ablations. Conclusion: MW ablation appears to be advantageous with respect to the volume of ablation and the shape of the margin of necrosis compared with RF ablation in an ex vivo bovine udder.
FERAL : Network-based classifier with application to breast cancer outcome prediction
Allahyar, A.; De Ridder, J.
2015-01-01
Motivation: Breast cancer outcome prediction based on gene expression profiles is an important strategy for personalize patient care. To improve performance and consistency of discovered markers of the initial molecular classifiers, network-based outcome prediction methods (NOPs) have been proposed.
Oddo, Silvia; Balestra, Margherita; Vera, Lara; Giusti, Massimo
2018-05-11
Radiofrequency ablation and laser ablation are safe and effective techniques for reducing thyroid nodule volume, neck symptoms, and cosmetic complaints. Therapeutic success is defined as a nodule reduction > 50% between 6 and 12 months after the procedure, but a percentage of nodules inexplicably do not respond to thermal ablation. We describe the case of a young Caucasian woman with a solid benign thyroid nodule who refused surgery and who had undergone radiofrequency ablation in 2013. The nodule did not respond in terms of either volume reduction or improvement in neck symptoms. After 2 years, given the patient's continued refusal of thyroidectomy, we proposed laser ablation. The nodule displayed a significant volume reduction (- 50% from radiofrequency ablation baseline volume, - 57% from laser ablation baseline), and the patient reported a significant improvement in neck symptoms (from 6/10 to 1/10 on a visual analogue scale). We conjecture that some benign thyroid nodules may be intrinsically resistant to necrosis when one specific ablation technique is used, but may respond to another technique. To the best of our knowledge, this is the first description of the effect of performing a different percutaneous ablation technique in a nodule that does not respond to radiofrequency ablation.
[Encopresis--predictive factors and outcome].
Mehler-Wex, Claudia; Scheuerpflug, Peter; Peschke, Nicole; Roth, Michael; Reitzle, Karl; Warnke, Andreas
2005-10-01
comparison of diagnostic, clinical and therapeutic features and their predictive value for the outcome of encopresis in children and adolescents. 85 children and adolescents (aged 9.6 +/- 3.2 years) with severe encopresis (ICD 10: F98.1) were investigated during inpatient treatment and 35 of them again 5.5 +/- 1.8 years later. Mentally retarded patients were excluded. Inpatient therapy consisted of treating constipation and/or stool regulation by means of laxatives, behavioural approaches, and the specific therapy of comorbid psychiatric disorders. During inpatient treatment 22% of the patients experienced total remission, 8% an unchanged persistence of symptoms. Of the 35 patients studied at follow-up 5.5 years later, 40% were symptom-free. As main result, prognostic outcome depended significantly on sufficient treatment of obstipation. Another important factor was the specific therapeutic approach to psychiatric comorbidity, especially to ADHD. The outcome for patients with comorbid ICD 10: F43 was significantly better than for the other patients. Those who were symptom-free at discharge had significantly better long-term outcomes. Decisive to the success of encopresis treatment were the stool regulation and the specific therapy of associated psychiatric illnesses, in particular of ADHD. Inpatient treatment revealed significantly better long-term outcomes where total remission had been achieved by the time of discharge from hospital.
Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.
O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E
2018-04-26
Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.
International Nuclear Information System (INIS)
Rhim, Hyunchul; Choi, Dongil; Kim, Young-sun; Lim, Hyo K.; Choe, Bong-Keun
2010-01-01
Purpose: This study was designed to evaluate whether a feasibility scoring system for planning sonography is a reliable predictor of a safe and complete ablation in ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs). Materials and methods: We retrospectively evaluated the therapeutic outcomes of 108 consecutive patients (M:F, 78:30; mean age, 57.4 years) with a single nodular HCC (mean diameter, 2.0 cm) treated by percutaneous RFA. All patients were assessed for the feasibility of performing an RFA at planning sonography prior to the ablation. The feasibility scoring system consisted of five categories: the safe electrode path (P); the vital organs adjacent to the RFA zone (O); tumor size (S); tumor conspicuity (C); and the heat-sink effect (H). Each category was divided into a four-point scale [1-4]. If a score of 4 in any category was determined, the patient was not considered to be a suitable candidate for percutaneous RFA. We assessed if the score of each category, safety score (P + O), and curability score (S + C + H) correlated with a safe and complete ablation using the chi-squared test and likelihood ratio test for trend. Results: The technical success rate was 100% (108/108) based on CT images obtained immediately after ablation. There was no 30-day mortality after RFA. There were major complications (one case of severe vasovagal reflex, one case of hemoperitoneum and one case of a pseudoaneurysm) in three (2.7%) patients, and minor complications (one case of a biloma, one case of subsegmental infarction and one case of abscess) in three (2.7%) patients. Post-ablation syndrome as a side effect was noted in 38 (35.1%) of 108 patients. The primary technique effectiveness rate at 1 month was 95.1% (105/108). Local tumor progression was noted in eight (7.6%) of 105 patients during the follow-up period (range, 3.0-11.5 months; median, 5.8 months; mean, 5.7 months). There was no significant single category
DEFF Research Database (Denmark)
Risom, Signe Stelling; Zwisler, Ann-Dorth Olsen; Rasmussen, Trine Bernholdt
2013-01-01
fibrillation treated with ablation. METHODS AND ANALYSIS DESIGN: The trial is a multicentre parallel arm design with 1:1 randomisation to the intervention and control group with blinded outcome assessment. 210 patients treated for atrial fibrillation with radiofrequency ablation will be included...... measure is exercise capacity measured by the VO(2) peak. The secondary outcome measure is self-rated mental health measured by the Short Form 36 questionnaire. Postintervention, qualitative interviews will be conducted in 10% of the intervention group. ETHICS AND DISSEMINATION: The protocol is approved...
Avdagić, Harun; Sijerčić Avdagić, Selma; Pirić Avdagić, Melika; Antonič, Miha
2017-12-01
Atrial fibrillation is associated with systemic embolization and complications due to anticoagulant therapy. Radiofrequency ablation has been established as an effective and safe method for the treatment of atrial fibrillation. The aim of this study was to evaluate the effect of the size of the left atrium on the outcome of surgical radiofrequency ablation. Forty patients scheduled for elective mitral valve surgery and radiofrequency ablation were enrolled in the study. Group 1 consisted of patients with a left atrium diameter ≤5 cm and group 2 of patients with left atrium diameter >5 cm. The primary endpoint of the study was stable sinus rhythm 6 months postoperatively. At 6 months postoperatively, sinus rhythm was present in significantly more group 1 patients as compared with group 2 patients, i.e. 15 (75%) vs. 8 (40%), p=0.025. Multivariate analysis proved the size of the left atrium to be an independent predictor of the radiofrequency ablation outcome. Accordingly, the size of the left atrium was demonstrated to be an important predictor of the outcome of radiofrequency ablation for atrial fibrillation. A lower cut-off value of surgical reduction of the atria than previously reported should be considered in order to improve the radiofrequency ablation outcome.
Directory of Open Access Journals (Sweden)
Walter Junior Boim Araujo
2015-12-01
Full Text Available Abstract Background Water-specific 1470-nm lasers enable vein ablation at lower energy densities and with fewer side effects because they target interstitial water in the vessel wall. Objectives To determine great saphenous vein (GSV occlusion rate after thermal ablation with 1470-nm laser using 7W power and to evaluate clinical outcomes and complications. Method Nineteen patients (31 GSVs underwent thermal ablation. Follow-up duplex scanning, clinical evaluation using the Venous Clinical Severity Score (VCSS, and evaluation of procedure-related complications were performed at 3-5 days after the procedure and at 30 and 180 days. Results Mean patient age was 46 years and 17 of the patients were female (89.47%. Of 31 limbs treated, 2 limbs were clinical class C2, 19 were C3, 9 were C4, and 1 limb was C5 according to the Clinical-Etiology-Anatomy-Pathophysiology (CEAP classification. Mean linear endovenous energy density was 33.53 J/cm. The GSV occlusion rate was 93.5% immediately after treatment, 100% at 3-5 days and 100% at 30 days after treatment and 87.1% 180 days after treatment. There was a significant reduction in VCSS at all time points. Conclusions The data from this study support the possibility that the incidence of complications can be reduced without significantly affecting the clinical outcomes, by using lower energy density. However, this appears to be at the cost of reduced efficacy in terms of GSV occlusion rates.
Dynamics of tissue shrinkage during ablative temperature exposures
International Nuclear Information System (INIS)
Rossmann, Christian; Haemmerich, Dieter; Garrett-Mayer, Elizabeth; Rattay, Frank
2014-01-01
There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occurs due to protein denaturation, dehydration and contraction of collagen at temperatures greater 50 °C. This is particularly relevant for image-guided procedures such as tumor ablation, where pre- and post-treatment images are compared and any changes in dimensions must be considered to avoid misinterpretations of the treatment outcome. We present data from ex vivo, isothermal shrinkage tests in porcine liver tissue, where axial changes in tissue length were recorded during 15 min of heating to temperatures between 60 and 95 °C. A mathematical model was developed to accurately describe the time and temperature-dependent shrinkage behavior. The shrinkage dynamics had the same characteristics independent of temperature; the estimated relative shrinkage, adjusted for time since death, after 15 min heating to temperatures of 60, 65, 75, 85 and 95 °C, was 12.3, 13.8, 16.6, 19.2 and 21.7%, respectively. Our results demonstrate the shrinkage dynamics of organ tissues, and suggest the importance of considering tissue shrinkage for thermal ablative treatments. (paper)
Arbelo, Elena; Brugada, Josep; Blomström-Lundqvist, Carina; Laroche, Cécile; Kautzner, Josef; Pokushalov, Evgeny; Raatikainen, Pekka; Efremidis, Michael; Hindricks, Gerhard; Barrera, Alberto; Maggioni, Aldo; Tavazzi, Luigi; Dagres, Nikolaos
2017-05-01
The ESC-EHRA Atrial Fibrillation Ablation Long-Term registry is a prospective, multinational study that aims at providing an accurate picture of contemporary real-world ablation for atrial fibrillation (AFib) and its outcome. A total of 104 centres in 27 European countries participated and were asked to enrol 20-50 consecutive patients scheduled for first and re-do AFib ablation. Pre-procedural, procedural and 1-year follow-up data were captured on a web-based electronic case record form. Overall, 3630 patients were included, of which 3593 underwent an AFib ablation (98.9%). Median age was 59 years and 32.4% patients had lone atrial fibrillation. Pulmonary vein isolation was attempted in 98.8% of patients and achieved in 95-97%. AFib-related symptoms were present in 97%. In-hospital complications occurred in 7.8% and one patient died due to an atrioesophageal fistula. One-year follow-up was performed in 3180 (88.6%) at a median of 12.4 months (11.9-13.4) after ablation: 52.8% by clinical visit, 44.2% by telephone contact and 3.0% by contact with the general practitioner. At 12-months, the success rate with or without antiarrhythmic drugs (AADs) was 73.6%. A significant portion (46%) was still on AADs. Late complications included 14 additional deaths (4 cardiac, 4 vascular, 6 other causes) and 333 (10.7%) other complications. AFib ablation in clinical practice is mostly performed in symptomatic, relatively young and otherwise healthy patients. Overall success rate is satisfactory, but complication rate remains considerable and a significant portion of patients remain on AADs. Monitoring after ablation shows wide variations. Antithrombotic treatment after ablation shows insufficient guideline-adherence. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.
[Predictive factors of the outcomes of prenatal hydronephrosis.
Bragagnini, Paolo; Estors, Blanca; Delgado, Reyes; Rihuete, Miguel Ángel; Gracia, Jesús
2016-12-01
To determine prenatal and postnatal independent predictors of poor outcome, spontaneous resolution, or the need for surgery in patients with prenatal hydronephrosis. We performed a retrospective study of patients with prenatal hydronephrosis. The renal pelvis APD was measured in the third prenatal trimester ultrasound, as well as in the first and second postnatal ultrasound. Other variables were taken into account, both prenatal and postnatal. For statistical analysis we used Student t-test, chi-square test, survival analysis, logrank test, and ROC curves. We included 218 patients with 293 renal units (RU). Of these, 147/293 (50.2%) RU were operated. 76/293 (25.9%) RU had spontaneous resolution and other 76/293 (25.9%) RU had poor outcome. As risk factors for surgery we found low birth weight (OR 3.84; 95% CI 1.24-11.84), prematurity (OR 4.17; 95% CI 1.35-12.88), duplication (OR 4.99; 95% CI 2.21-11.23) and the presence of nephrourological underlying pathology (OR 53.54; 95% CI 26.23-109.27). For the non-spontaneous resolution, we found as risk factors the alterations of amniotic fluid volume (RR 1.46; 95% CI 1.33-1.60) as well as the underlying nephrourological pathology and duplication. In the poor outcome, we found as risk factors the alterations of amniotic fluid volume (OR 4.54; 95% CI 1.31-15.62), the presence of nephrourological pathology (OR 4.81 95% CI 2.60-8.89) and RU that was operated (OR 4.23, 95% CI 2.35-7.60). The APD of the renal pelvis in all three ultrasounds were reliable for surgery prediction (area under the curve 0.65; 0.82; 0.71) or spontaneous resolution (area under the curve 0.80; 0.91; 0.80), only the first postnatal ultrasound has predictive value in the poor outcome (area under the curve 0.73). The higher sensitivity and specificity of the APD as predictor value was on the first postnatal ultrasound, 14.60 mm for surgery; 11.35 mm for spontaneous resolution and 15.50 mm for poor outcome. The higher APD in the renal pelvis in any of the
Atmospheric pressure arc discharge with ablating graphite anode
International Nuclear Information System (INIS)
Nemchinsky, V A; Raitses, Y
2015-01-01
The anodic carbon arc discharge is used to produce carbon nanoparticles. Recent experiments with the carbon arc at atmospheric pressure helium demonstrated the enhanced ablation rate for narrow graphite anodes resulting in high deposition rates of carbonaceous products on the copper cathode (Fetterman et al 2008 Carbon 46 1322–6). The proposed model explains these results with interconnected steady-state models of the cathode and the anode processes. When considering cathode functioning, the model predicts circulation of the particles in the near-cathode region: evaporation of the cathode material, ionization of evaporated atoms and molecules in the near-cathode plasma, return of the resulting ions to the cathode, surface recombination of ions and electrons followed again by cathode evaporation etc. In the case of the low anode ablation rate, the ion acceleration in the cathode sheath provides the major cathode heating mechanism. In the case of an intensive anode ablation, an additional cathode heating is due to latent fusion heat of the atomic species evaporated from the anode and depositing at the cathode. Using the experimental arc voltage as the only input discharge parameter, the model allows us to calculate the anode ablation rate. A comparison of the results of calculations with the available experimental data shows reasonable agreement. (paper)
Atmospheric pressure arc discharge with ablating graphite anode
Nemchinsky, V. A.; Raitses, Y.
2015-06-01
The anodic carbon arc discharge is used to produce carbon nanoparticles. Recent experiments with the carbon arc at atmospheric pressure helium demonstrated the enhanced ablation rate for narrow graphite anodes resulting in high deposition rates of carbonaceous products on the copper cathode (Fetterman et al 2008 Carbon 46 1322-6). The proposed model explains these results with interconnected steady-state models of the cathode and the anode processes. When considering cathode functioning, the model predicts circulation of the particles in the near-cathode region: evaporation of the cathode material, ionization of evaporated atoms and molecules in the near-cathode plasma, return of the resulting ions to the cathode, surface recombination of ions and electrons followed again by cathode evaporation etc. In the case of the low anode ablation rate, the ion acceleration in the cathode sheath provides the major cathode heating mechanism. In the case of an intensive anode ablation, an additional cathode heating is due to latent fusion heat of the atomic species evaporated from the anode and depositing at the cathode. Using the experimental arc voltage as the only input discharge parameter, the model allows us to calculate the anode ablation rate. A comparison of the results of calculations with the available experimental data shows reasonable agreement.
Vietti Violi, Naïk; Duran, Rafael; Guiu, Boris; Cercueil, Jean-Pierre; Aubé, Christophe; Digklia, Antonia; Pache, Isabelle; Deltenre, Pierre; Knebel, Jean-François; Denys, Alban
2018-05-01
Radiofrequency ablation is the recommended treatment for patients with hepatocellular carcinoma who have lesions smaller than 3 cm and are therefore not candidates for surgery. Microwave ablation is a more recent technique with certain theoretical advantages that have not yet been confirmed clinically. We aimed to compare the efficacy of both techniques in the treatment of hepatocellular carcinoma lesions of 4 cm or smaller. We did a randomised controlled, single-blinded phase 2 trial at four tertiary university centres in France and Switzerland. Patients with chronic liver disease and hepatocellular carcinoma with up to three lesions of 4 cm or smaller who were not eligible for surgery were randomised to receive microwave ablation (experimental group) or radiofrequency ablation (control group). Randomisation was centralised and done by use of a fixed block method (block size 4). Patients were randomly assigned by a co-investigator by use of the sealed opaque envelope method and were masked to the treatment; physicians were not masked to treatment, since the devices used were different. The primary outcome was the proportion of lesions with local tumour progression at 2 years of follow-up. Local tumour progression was defined as the appearance of a new nodule with features typical of hepatocellular carcinoma in the edge of the ablation zone. All analyses were done in the per-protocol population. The study is completed, but patients will continue to be followed up for 5 years. This study is registered with ClinicalTrials.gov, number NCT02859753. Between Nov 15, 2011, and Feb 27, 2015, 152 patients were randomly assigned: 76 patients to receive microwave ablation and 76 patients to receive radiofrequency ablation. For the per-protocol analysis, five patients were excluded from the microwave ablation group as were three patients from the radiofrequency ablation group. Median follow-up was 26 months (IQR 18-29) in the microwave ablation group and 25 months (18-34) in
DEFF Research Database (Denmark)
Henningsen, Kristoffer Mads Aaris; Nilsson, Brian; Bruunsgaard, Helle
2008-01-01
Aim. The aim of this study was to assess the predictive value of inflammatory markers in patients with paroxysmal/ persistent atrial fibrillation (AF) treated with radiofrequency (RF) catheter ablation. Methods. Forty-six consecutive patients, mean age 55 years (range 31 - 81 yrs), with paroxysmal...... >10 minutes was considered failure and patients were offered a second ablation session. Interleukin-6 and high-sensitivity C-reactive protein were measured prior to ablation and at follow-up visits. Results. After a maximum of two ablations, 19 patients (41%) had SR without recurrence of AF after 12...
International Nuclear Information System (INIS)
Park, Jonathan K.; Al-Tariq, Quazi Z.; Zaw, Taryar M.; Raman, Steven S.; Lu, David S.K.
2015-01-01
PurposeTo assess radiofrequency (RF) ablation efficacy, as well as the patency of transjugular intrahepatic portosystemic shunts (TIPSs), in patients with hepatocellular carcinoma (HCC).Materials and MethodsRetrospective database review of patients with pre-existing TIPS undergoing RF ablation of HCC was conducted over a 159-month period ending in November 2013. TIPS patency pre- and post-RF ablation was assessed by ultrasound, angiography, and/or contrast-enhanced CT or MRI. Patient demographics and immediate post-RF ablation outcomes and complications were also reviewed.Results19 patients with 21 lesions undergoing 25 RF ablation sessions were included. Child-Pugh class A, B, and C scores were seen in 1, 13, and 5 patients, respectively. Eleven patients (58 %) ultimately underwent liver transplantation. Immediate technical success was seen in all ablation sessions without residual tumor enhancement (100 %). No patients (0 %) suffered liver failure within 1 month of ablation. Pre-ablation TIPS patency was demonstrated in 22/25 sessions (88 %). Of 22 cases with patent TIPS prior to ablation, post-ablation patency was demonstrated in 22/22 (100 %) at immediate post-ablation imaging and in 21/22 (95 %) at last follow-up (1 patient was incidentally noted to have occlusion 31 months later). No immediate complications were observed.ConclusionAblation efficacy was similar to the cited literature values for patients without TIPS. Furthermore, TIPS patency was preserved in the majority of cases. Patients with both portal hypertension and HCC are not uncommonly encountered, and a pre-existing TIPS does not appear to be a definite contraindication for RF ablation
Energy Technology Data Exchange (ETDEWEB)
Park, Jonathan K., E-mail: jonathan.park09@gmail.com [David Geffen School of Medicine at UCLA, Department of Radiology (United States); Al-Tariq, Quazi Z., E-mail: qat200@gmail.com [Stanford University School of Medicine, Department of Radiology (United States); Zaw, Taryar M., E-mail: taryar.zaw@gmail.com; Raman, Steven S., E-mail: sraman@mednet.ucla.edu; Lu, David S.K., E-mail: dlu@mednet.ucla.edu [David Geffen School of Medicine at UCLA, Department of Radiology (United States)
2015-10-15
PurposeTo assess radiofrequency (RF) ablation efficacy, as well as the patency of transjugular intrahepatic portosystemic shunts (TIPSs), in patients with hepatocellular carcinoma (HCC).Materials and MethodsRetrospective database review of patients with pre-existing TIPS undergoing RF ablation of HCC was conducted over a 159-month period ending in November 2013. TIPS patency pre- and post-RF ablation was assessed by ultrasound, angiography, and/or contrast-enhanced CT or MRI. Patient demographics and immediate post-RF ablation outcomes and complications were also reviewed.Results19 patients with 21 lesions undergoing 25 RF ablation sessions were included. Child-Pugh class A, B, and C scores were seen in 1, 13, and 5 patients, respectively. Eleven patients (58 %) ultimately underwent liver transplantation. Immediate technical success was seen in all ablation sessions without residual tumor enhancement (100 %). No patients (0 %) suffered liver failure within 1 month of ablation. Pre-ablation TIPS patency was demonstrated in 22/25 sessions (88 %). Of 22 cases with patent TIPS prior to ablation, post-ablation patency was demonstrated in 22/22 (100 %) at immediate post-ablation imaging and in 21/22 (95 %) at last follow-up (1 patient was incidentally noted to have occlusion 31 months later). No immediate complications were observed.ConclusionAblation efficacy was similar to the cited literature values for patients without TIPS. Furthermore, TIPS patency was preserved in the majority of cases. Patients with both portal hypertension and HCC are not uncommonly encountered, and a pre-existing TIPS does not appear to be a definite contraindication for RF ablation.
Using predictive analytics and big data to optimize pharmaceutical outcomes.
Hernandez, Inmaculada; Zhang, Yuting
2017-09-15
The steps involved, the resources needed, and the challenges associated with applying predictive analytics in healthcare are described, with a review of successful applications of predictive analytics in implementing population health management interventions that target medication-related patient outcomes. In healthcare, the term big data typically refers to large quantities of electronic health record, administrative claims, and clinical trial data as well as data collected from smartphone applications, wearable devices, social media, and personal genomics services; predictive analytics refers to innovative methods of analysis developed to overcome challenges associated with big data, including a variety of statistical techniques ranging from predictive modeling to machine learning to data mining. Predictive analytics using big data have been applied successfully in several areas of medication management, such as in the identification of complex patients or those at highest risk for medication noncompliance or adverse effects. Because predictive analytics can be used in predicting different outcomes, they can provide pharmacists with a better understanding of the risks for specific medication-related problems that each patient faces. This information will enable pharmacists to deliver interventions tailored to patients' needs. In order to take full advantage of these benefits, however, clinicians will have to understand the basics of big data and predictive analytics. Predictive analytics that leverage big data will become an indispensable tool for clinicians in mapping interventions and improving patient outcomes. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
A Review of Laser Ablation Propulsion
International Nuclear Information System (INIS)
Phipps, Claude; Bohn, Willy; Lippert, Thomas; Sasoh, Akihiro; Schall, Wolfgang; Sinko, John
2010-01-01
Laser Ablation Propulsion is a broad field with a wide range of applications. We review the 30-year history of laser ablation propulsion from the transition from earlier pure photon propulsion concepts of Oberth and Saenger through Kantrowitz's original laser ablation propulsion idea to the development of air-breathing 'Lightcraft' and advanced spacecraft propulsion engines. The polymers POM and GAP have played an important role in experiments and liquid ablation fuels show great promise. Some applications use a laser system which is distant from the propelled object, for example, on another spacecraft, the Earth or a planet. Others use a laser that is part of the spacecraft propulsion system on the spacecraft. Propulsion is produced when an intense laser beam strikes a condensed matter surface and produces a vapor or plasma jet. The advantages of this idea are that exhaust velocity of the propulsion engine covers a broader range than is available from chemistry, that it can be varied to meet the instantaneous demands of the particular mission, and that practical realizations give lower mass and greater simplicity for a payload delivery system. We review the underlying theory, buttressed by extensive experimental data. The primary problem in laser space propulsion theory has been the absence of a way to predict thrust and specific impulse over the transition from the vapor to the plasma regimes. We briefly discuss a method for combining two new vapor regime treatments with plasma regime theory, giving a smooth transition from one regime to the other. We conclude with a section on future directions.
Kdous, Moez; Jacob, Denis; Gervaise, Amélie; Risk, Elie; Sauvanet, Eric
2008-05-01
Thermal balloon endometrial ablation is a new operative technique recently proposed in the treatment of dysfunctional uterine bleeding. To evaluate the efficacy of thermal balloon endometrial ablation in the treatment of dysfunctional uterine bleeding, and to identify the possible predictive factors for a successful outcome. A prospective study was conducted including 152 patients with chronic abnormal uterine bleeding refractory to medical treatment. All patients were treated by thermal balloon endometrial ablation (Thermachoice, Gynecare) between January 1, 1996 and December 31, 2003. patients were included if their uterine cavities sounded to less than 12 cm and had undergone hysteroscopy, pelvic ultrasound and endometrial biopsie showing no structural or (pre) malignant endometrial abnormalities. A balloon catheter was placed through the cervix and after inflation in the endometrial cavity with 5% dextrose in water, was heated to 87 +/- 5 degrees C. No one required cervical dilatation. Balloon pressures were 160 to 170 mm Hg. All patients underwent 8 minutes of therapy. The average patient was 47 years (range: 30-62 years) and was followed for a mean of 3 years and 7 months (range: 6 months - 8 years). 31.6% of women reported amennorhea, 16.5% hypomenorrhea and 21% eumenorrhea. Menorrhagea persisted in 11.2% of patients. No intraoperative complications and minor postoperative morbidity occured in 10.5% of patients. Three prgnancy complicated by spontaneous abortions were reported after the treatment. A total of 78% of women reported overall satisfaction with the endometrial ablation procedure and 18% were dissatisfied. 17.8% of patients underwent hysterectomy within 1 to 5 years of balloon endometrial ablation. Increasing age and menopause were significantly associated with increased odds of success (p < 0.05). Thermal balloon endometrial ablation is a simple, easy, effective, and minimally invasive procedure in menhorragic women with no desire for further
Energy Technology Data Exchange (ETDEWEB)
Xu, H.-X.; Xie, X.-Y.; Lu, M.-D. E-mail: lumd@21cn.com; Chen, J.-W.; Yin, X.-Y.; Xu, Z.-F.; Liu, G.-J
2004-01-01
AIM: To investigate the therapeutic efficacy of thermal ablation for treatment of hepatocellular carcinoma (HCC) using microwave and radiofrequency (RF) energy application. MATERIALS AND METHODS: A total of 190 nodules in 97 patients (84 male, 13 female; mean age 53.4 years, range 24-74 years) with HCC were treated with microwave or RF ablation in the last 4 years. The applicators were introduced into the tumours under conscious analgesic sedation by intravenous administration of fentanyl citrate and droperidol and local anaesthesia in both thermal ablation procedures. The patients were then followed up with contrast-enhanced computed tomography (CT) to evaluate treatment response. Survival was analysed using the Kaplan-Meier method. RESULTS: Complete ablation was obtained in 92.6% (176/190) nodules. The complete ablation rates were 94.6% (106/112) in microwave ablation and 89.7% (70/78) in RF ablation. The complete ablation rates in tumours{<=}2.0, 2.1-3.9 and {>=}4.0 cm were 93.1, 93.8 and 86.4%, respectively. Local recurrence was found in 9.5% nodules and the rates in tumours{<=}2.0, 2.1-3.9 and {>=}4.0 cm in diameter were 3.4, 9.9 and 31.8%, respectively. In the follow-up period, 7.1% nodules ablated by microwave and 12.8% by RF presented local recurrence. The 1, 2 and 3-year distant recurrence-free survivals were 47.2, 34.9 and 31.0%, respectively. Estimated mean survival was 32 months, and 1, 2 and 3-year cumulative survivals were 75.6, 58.5, and 50.0%, respectively. One and 2 years survivals of Child-Pugh class A, B and C patients were 83.8 and 70.4%, 78.2 and 53.2%, 36.3 and 27.3%, respectively. CONCLUSION: Thermal ablation therapy by means of microwave and RF energy application is an effective and safe therapeutic technique for hepatocellular carcinoma. Large tumours can be completely ablated, but have a significantly higher risk of local recurrence at follow-up.
International Nuclear Information System (INIS)
Xu, H.-X.; Xie, X.-Y.; Lu, M.-D.; Chen, J.-W.; Yin, X.-Y.; Xu, Z.-F.; Liu, G.-J.
2004-01-01
AIM: To investigate the therapeutic efficacy of thermal ablation for treatment of hepatocellular carcinoma (HCC) using microwave and radiofrequency (RF) energy application. MATERIALS AND METHODS: A total of 190 nodules in 97 patients (84 male, 13 female; mean age 53.4 years, range 24-74 years) with HCC were treated with microwave or RF ablation in the last 4 years. The applicators were introduced into the tumours under conscious analgesic sedation by intravenous administration of fentanyl citrate and droperidol and local anaesthesia in both thermal ablation procedures. The patients were then followed up with contrast-enhanced computed tomography (CT) to evaluate treatment response. Survival was analysed using the Kaplan-Meier method. RESULTS: Complete ablation was obtained in 92.6% (176/190) nodules. The complete ablation rates were 94.6% (106/112) in microwave ablation and 89.7% (70/78) in RF ablation. The complete ablation rates in tumours≤2.0, 2.1-3.9 and ≥4.0 cm were 93.1, 93.8 and 86.4%, respectively. Local recurrence was found in 9.5% nodules and the rates in tumours≤2.0, 2.1-3.9 and ≥4.0 cm in diameter were 3.4, 9.9 and 31.8%, respectively. In the follow-up period, 7.1% nodules ablated by microwave and 12.8% by RF presented local recurrence. The 1, 2 and 3-year distant recurrence-free survivals were 47.2, 34.9 and 31.0%, respectively. Estimated mean survival was 32 months, and 1, 2 and 3-year cumulative survivals were 75.6, 58.5, and 50.0%, respectively. One and 2 years survivals of Child-Pugh class A, B and C patients were 83.8 and 70.4%, 78.2 and 53.2%, 36.3 and 27.3%, respectively. CONCLUSION: Thermal ablation therapy by means of microwave and RF energy application is an effective and safe therapeutic technique for hepatocellular carcinoma. Large tumours can be completely ablated, but have a significantly higher risk of local recurrence at follow-up
Outcome Prediction in Mathematical Models of Immune Response to Infection.
Directory of Open Access Journals (Sweden)
Manuel Mai
Full Text Available Clinicians need to predict patient outcomes with high accuracy as early as possible after disease inception. In this manuscript, we show that patient-to-patient variability sets a fundamental limit on outcome prediction accuracy for a general class of mathematical models for the immune response to infection. However, accuracy can be increased at the expense of delayed prognosis. We investigate several systems of ordinary differential equations (ODEs that model the host immune response to a pathogen load. Advantages of systems of ODEs for investigating the immune response to infection include the ability to collect data on large numbers of 'virtual patients', each with a given set of model parameters, and obtain many time points during the course of the infection. We implement patient-to-patient variability v in the ODE models by randomly selecting the model parameters from distributions with coefficients of variation v that are centered on physiological values. We use logistic regression with one-versus-all classification to predict the discrete steady-state outcomes of the system. We find that the prediction algorithm achieves near 100% accuracy for v = 0, and the accuracy decreases with increasing v for all ODE models studied. The fact that multiple steady-state outcomes can be obtained for a given initial condition, i.e. the basins of attraction overlap in the space of initial conditions, limits the prediction accuracy for v > 0. Increasing the elapsed time of the variables used to train and test the classifier, increases the prediction accuracy, while adding explicit external noise to the ODE models decreases the prediction accuracy. Our results quantify the competition between early prognosis and high prediction accuracy that is frequently encountered by clinicians.
ASTRAL, DRAGON and SEDAN scores predict stroke outcome more accurately than physicians.
Ntaios, G; Gioulekas, F; Papavasileiou, V; Strbian, D; Michel, P
2016-11-01
ASTRAL, SEDAN and DRAGON scores are three well-validated scores for stroke outcome prediction. Whether these scores predict stroke outcome more accurately compared with physicians interested in stroke was investigated. Physicians interested in stroke were invited to an online anonymous survey to provide outcome estimates in randomly allocated structured scenarios of recent real-life stroke patients. Their estimates were compared to scores' predictions in the same scenarios. An estimate was considered accurate if it was within 95% confidence intervals of actual outcome. In all, 244 participants from 32 different countries responded assessing 720 real scenarios and 2636 outcomes. The majority of physicians' estimates were inaccurate (1422/2636, 53.9%). 400 (56.8%) of physicians' estimates about the percentage probability of 3-month modified Rankin score (mRS) > 2 were accurate compared with 609 (86.5%) of ASTRAL score estimates (P DRAGON score estimates (P DRAGON score estimates (P DRAGON and SEDAN scores predict outcome of acute ischaemic stroke patients with higher accuracy compared to physicians interested in stroke. © 2016 EAN.
Carbucicchio, Corrado; Santamaria, Matteo; Trevisi, Nicola; Maccabelli, Giuseppe; Giraldi, Francesco; Fassini, Gaetano; Riva, Stefania; Moltrasio, Massimo; Cireddu, Manuela; Veglia, Fabrizio; Della Bella, Paolo
2008-01-29
Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing > or = 1 clinical VT still inducible after catheter ablation. Advanced strategies of catheter ablation
Neurophysiological prediction of neurological good and poor outcome in post-anoxic coma.
Grippo, A; Carrai, R; Scarpino, M; Spalletti, M; Lanzo, G; Cossu, C; Peris, A; Valente, S; Amantini, A
2017-06-01
Investigation of the utility of association between electroencephalogram (EEG) and somatosensory-evoked potentials (SEPs) for the prediction of neurological outcome in comatose patients resuscitated after cardiac arrest (CA) treated with therapeutic hypothermia, according to different recording times after CA. Glasgow Coma Scale, EEG and SEPs performed at 12, 24 and 48-72 h after CA were assessed in 200 patients. Outcome was evaluated by Cerebral Performance Category 6 months after CA. Within 12 h after CA, grade 1 EEG predicted good outcome and bilaterally absent (BA) SEPs predicted poor outcome. Because grade 1 EEG and BA-SEPs were never found in the same patient, the recording of both EEG and SEPs allows us to correctly prognosticate a greater number of patients with respect to the use of a single test within 12 h after CA. At 48-72 h after CA, both grade 2 EEG and BA-SEPs predicted poor outcome with FPR=0.0%. When these neurophysiological patterns are both present in the same patient, they confirm and strengthen their prognostic value, but because they also occurred independently in eight patients, poor outcome is predictable in a greater number of patients. The combination of EEG/SEP findings allows prediction of good and poor outcome (within 12 h after CA) and of poor outcome (after 48-72 h). Recording of EEG and SEPs in the same patients allows always an increase in the number of cases correctly classified, and an increase of the reliability of prognostication in a single patient due to concordance of patterns. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ablation threshold and ablation mechanism transition of polyoxymethylene irradiated by CO2 laser.
Li, Gan; Cheng, Mousen; Li, Xiaokang
2016-09-01
Polyoxymethylene (POM) decomposes gradually as it is heated up by the irradiation of CO2 laser; the long-chain molecules of POM are broken into short chains, which leads to the lowering of the melting point and the critical temperature of the ablation products. When the product temperature is above the melting point, ablation comes up in the way of vaporization; when the product temperature is higher than the critical temperature, all liquid products are transformed into gas instantly and the ablation mechanism is changed. The laser fluence at which significant ablation is observed is defined as the ablation threshold, and the fluence corresponding to the ablation mechanism changing is denoted as the flyover threshold. In this paper, random pyrolysis is adopted to describe the pyrolytic decomposition of POM, and consequently, the components of the pyrolysis products under different pyrolysis rates are acquired. The Group Contribution method is used to count the thermodynamic properties of the pyrolysis products, and the melting point and the critical temperature of the product mixture are obtained by the Mixing Law. The Knudsen layer relationship is employed to evaluate the ablation mass removal when the product temperature is below the critical temperature. The gas dynamics conservation laws associated with the Jouguet condition are used to calculate the mass removal when the product temperature is higher than the critical temperature. Based on the model, a set of simulations for various laser intensities and lengths are carried out to generalize the relationships between the thresholds and the laser parameters. Besides the ablated mass areal density, which fits the experimental data quite well, the ablation temperature, pyrolysis rate, and product components are also discussed for a better understanding of the ablation mechanism of POM.
Directory of Open Access Journals (Sweden)
Wei Wei
Full Text Available BACKGROUND: The relationship between focal pulmonary vein potential and atrial fibrillation (AF has been confirmed. Pulmonary vein (PV isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation. METHODOLOGY: For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up. PRINCIPAL FINDINGS: During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05. Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation. CONCLUSIONS: The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.
Computational Modeling of Ablation on an Irradiated Target
Mehmedagic, Igbal; Thangam, Siva
2017-11-01
Computational modeling of pulsed nanosecond laser interaction with an irradiated metallic target is presented. The model formulation involves ablation of the metallic target irradiated by pulsed high intensity laser at normal atmospheric conditions. Computational findings based on effective representation and prediction of the heat transfer, melting and vaporization of the targeting material as well as plume formation and expansion are presented along with its relevance for the development of protective shields. In this context, the available results for a representative irradiation from 1064 nm laser pulse is used to analyze various ablation mechanisms, variable thermo-physical and optical properties, plume expansion and surface geometry. Funded in part by U. S. Army ARDEC, Picatinny Arsenal, NJ.
Real-time tumor ablation simulation based on the dynamic mode decomposition method
Bourantas, George C.
2014-05-01
Purpose: The dynamic mode decomposition (DMD) method is used to provide a reliable forecasting of tumor ablation treatment simulation in real time, which is quite needed in medical practice. To achieve this, an extended Pennes bioheat model must be employed, taking into account both the water evaporation phenomenon and the tissue damage during tumor ablation. Methods: A meshless point collocation solver is used for the numerical solution of the governing equations. The results obtained are used by the DMD method for forecasting the numerical solution faster than the meshless solver. The procedure is first validated against analytical and numerical predictions for simple problems. The DMD method is then applied to three-dimensional simulations that involve modeling of tumor ablation and account for metabolic heat generation, blood perfusion, and heat ablation using realistic values for the various parameters. Results: The present method offers very fast numerical solution to bioheat transfer, which is of clinical significance in medical practice. It also sidesteps the mathematical treatment of boundaries between tumor and healthy tissue, which is usually a tedious procedure with some inevitable degree of approximation. The DMD method provides excellent predictions of the temperature profile in tumors and in the healthy parts of the tissue, for linear and nonlinear thermal properties of the tissue. Conclusions: The low computational cost renders the use of DMD suitable forin situ real time tumor ablation simulations without sacrificing accuracy. In such a way, the tumor ablation treatment planning is feasible using just a personal computer thanks to the simplicity of the numerical procedure used. The geometrical data can be provided directly by medical image modalities used in everyday practice. © 2014 American Association of Physicists in Medicine.
Energy Technology Data Exchange (ETDEWEB)
Nicolodelli, Gustavo, E-mail: nicolodelli@ursa.ifsc.usp.br [Instituto de Fisica de Sao Carlos, University of Sao Paulo, Grupo de Optica, Av. Trabalhador Sancarlense 400, P.O. Box 369, CEP 13560-970, Sao Carlos, SP (Brazil); Kurachi, Cristina; Bagnato, Vanderlei Salvador [Instituto de Fisica de Sao Carlos, University of Sao Paulo, Grupo de Optica, Av. Trabalhador Sancarlense 400, P.O. Box 369, CEP 13560-970, Sao Carlos, SP (Brazil)
2011-01-15
Femtosecond laser ablation of materials is turning to be an important tool for micromachining as well as for selective removal of biological tissues. In a great number of applications, laser ablation has to process through interfaces separating media of different properties. The investigation of the ablation behavior within materials and passing through interfaces is the main aim of this study. Especially, the analysis of the discontinuity in the ablation profile close to interfaces between distinct materials can reveal some of the phenomena involved in the formation of an ablated microcavity geometry. We have used a method that correlates the ablation cross sectional area with the local laser intensity. The effective intensity ablation properties were obtained from surface ablation data of distinct materials. The application of this method allows the prediction of the occurrence of a size discontinuity in the ablation geometry at the interface of distinct media, a fact which becomes important when planning applications in different media.
Prediction of Outcome in Acute Lower Gastrointestinal Bleeding Using Gradient Boosting.
Directory of Open Access Journals (Sweden)
Lakshmana Ayaru
Full Text Available There are no widely used models in clinical care to predict outcome in acute lower gastro-intestinal bleeding (ALGIB. If available these could help triage patients at presentation to appropriate levels of care/intervention and improve medical resource utilisation. We aimed to apply a state-of-the-art machine learning classifier, gradient boosting (GB, to predict outcome in ALGIB using non-endoscopic measurements as predictors.Non-endoscopic variables from patients with ALGIB attending the emergency departments of two teaching hospitals were analysed retrospectively for training/internal validation (n=170 and external validation (n=130 of the GB model. The performance of the GB algorithm in predicting recurrent bleeding, clinical intervention and severe bleeding was compared to a multiple logic regression (MLR model and two published MLR-based prediction algorithms (BLEED and Strate prediction rule.The GB algorithm had the best negative predictive values for the chosen outcomes (>88%. On internal validation the accuracy of the GB algorithm for predicting recurrent bleeding, therapeutic intervention and severe bleeding were (88%, 88% and 78% respectively and superior to the BLEED classification (64%, 68% and 63%, Strate prediction rule (78%, 78%, 67% and conventional MLR (74%, 74% 62%. On external validation the accuracy was similar to conventional MLR for recurrent bleeding (88% vs. 83% and therapeutic intervention (91% vs. 87% but superior for severe bleeding (83% vs. 71%.The gradient boosting algorithm accurately predicts outcome in patients with acute lower gastrointestinal bleeding and outperforms multiple logistic regression based models. These may be useful for risk stratification of patients on presentation to the emergency department.
Androgen receptor profiling predicts prostate cancer outcome
S. Stelloo (Suzan); E. Nevedomskaya (Ekaterina); H.G. van der Poel (Henk G.); J. de Jong (Jeroen); G.J.H.L. Leenders (Geert); G.W. Jenster (Guido); L. Wessels (Lodewyk); A.M. Bergman (Andries); W. Zwart (Wilbert)
2015-01-01
textabstractProstate cancer is the second most prevalent malignancy in men. Biomarkers for outcome prediction are urgently needed, so that high-risk patients could be monitored more closely postoperatively. To identify prognostic markers and to determine causal players in prostate cancer
Perceived Masculinity Predicts U.S. Supreme Court Outcomes
2016-01-01
Previous studies suggest a significant role of language in the court room, yet none has identified a definitive correlation between vocal characteristics and court outcomes. This paper demonstrates that voice-based snap judgments based solely on the introductory sentence of lawyers arguing in front of the Supreme Court of the United States predict outcomes in the Court. In this study, participants rated the opening statement of male advocates arguing before the Supreme Court between 1998 and 2012 in terms of masculinity, attractiveness, confidence, intelligence, trustworthiness, and aggressiveness. We found significant correlation between vocal characteristics and court outcomes and the correlation is specific to perceived masculinity even when judgment of masculinity is based only on less than three seconds of exposure to a lawyer’s speech sample. Specifically, male advocates are more likely to win when they are perceived as less masculine. No other personality dimension predicts court outcomes. While this study does not aim to establish any causal connections, our findings suggest that vocal characteristics may be relevant in even as solemn a setting as the Supreme Court of the United States. PMID:27737008
Perceived Masculinity Predicts U.S. Supreme Court Outcomes.
Directory of Open Access Journals (Sweden)
Daniel Chen
Full Text Available Previous studies suggest a significant role of language in the court room, yet none has identified a definitive correlation between vocal characteristics and court outcomes. This paper demonstrates that voice-based snap judgments based solely on the introductory sentence of lawyers arguing in front of the Supreme Court of the United States predict outcomes in the Court. In this study, participants rated the opening statement of male advocates arguing before the Supreme Court between 1998 and 2012 in terms of masculinity, attractiveness, confidence, intelligence, trustworthiness, and aggressiveness. We found significant correlation between vocal characteristics and court outcomes and the correlation is specific to perceived masculinity even when judgment of masculinity is based only on less than three seconds of exposure to a lawyer's speech sample. Specifically, male advocates are more likely to win when they are perceived as less masculine. No other personality dimension predicts court outcomes. While this study does not aim to establish any causal connections, our findings suggest that vocal characteristics may be relevant in even as solemn a setting as the Supreme Court of the United States.
Laser Ablation Experiments on the Tamdakht H5 Chondrite
White, Susan M.; Stern, Eric
2017-01-01
High-powered lasers were used to induce ablation and to form fusion crusts in the lab on Tamdakht H5 chondrites and basalt. These ground tests were undertaken to improve our understanding, and ultimately improve our abilty to model and predict, meteoroid ablation during atmospheric entry. The infrared fiber laser at the LHMEL facilty, operated in the continuous wave (i.e. non-pulsed) mode, provided radiation surface heat flux at levels similar to meteor entry for these tests. Results are presented from the first round of testing on samples of Tamdakht H5 ordinary chondrite which were ex-posed to entry-relevant heating rates between 2 and 10 kWcm2.
Reliability of computerized cephalometric outcome predictions of mandibular set-back surgery
Directory of Open Access Journals (Sweden)
Stefanović Neda
2011-01-01
Full Text Available Introduction. A successful treatment outcome in dentofacial deformity patients commonly requires combined orthodontic-surgical therapy. This enables us to overcome functional, aesthetic and psychological problems. Since most patients state aesthetics as the primary motive for seeking therapy, cephalometric predictions of treatment outcome have become the essential part of treatment planning, especially in combined orthodontic-surgical cases. Objective. The aim of this study was to evaluate the validity and reliability of computerized orthognathic surgery outcome predictions generated using the Nemotec Dental Studio NX 2005 software. Methods. The sample of the study consisted of 31 patients diagnosed with mandibular prognathism who were surgically treated at the Hospital for Maxillofacial Surgery in Belgrade. Investigation was done on lateral cephalograms made before and after surgical treatment. Cephalograms were digitized and analyzed using computer software. According to measurements made on superimposed pre- and postsurgical cephalograms, the patients were retreated within the software and the predictions were assessed by measuring seven angular and three linear parameters. Prediction measurements were then compared with the actual outcome. Results. Results showed statistically significant changes between posttreatment and predicted values for parameters referring to lower lip and mentolabial sulcus position. Conclusion. Computerized cephalometric predictions for hard-tissue structures in the sagittal and vertical planes, as well as the VTO parameters, generated using the Nemotec Dental Studio NX 2005 software are reliable, while lower lip and mentolabial sulcus position predictions are not reliable enough.
A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.
Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard
2016-01-01
Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially
Photoactive dye-enhanced tissue ablation for endoscopic laser prostatectomy.
Ahn, Minwoo; Hau, Nguyen Trung; Van Phuc, Nguyen; Oh, Junghwan; Kang, Hyun Wook
2014-11-01
efficient coupling of optical energy, pre-injection of photoactive dyes promoted the degree of tissue removal during laser irradiation. Further studies will investigate spatial distribution of dyes and optimal injecting pressure to govern the extent of dye-assisted ablation in a predictable manner. In-depth comprehension on photoactive dye-enhanced tissue ablation can help accomplish efficient and safe laser vaporization for BPH with low power application. © 2014 Wiley Periodicals, Inc.
Experimental investigations on vessel-hole ablation during severe accidents
International Nuclear Information System (INIS)
Sehgal, B.R.; Dinh, T.N.; Green, J.A.; Paladino, D.
1997-12-01
This report presents experimental results, and subsequent analyses, of scaled reactor pressure vessel (RPV) failure site ablation tests conducted at the Royal Institute of Technology, Division of Nuclear Power Safety (RIT/NPS). The goal of the test program is to reduce the uncertainty level associated with the phase-change-ablation process, and, thus, improve the characterization of the melt discharge loading on the containment. In a series of moderate temperature experiments, the corium melt is simulated by the binary oxide CaO-B 2 O 3 or the binary eutectic and non-eutectic salts NaNO 3 -KNO 3 , while the RPV head steel is represented by a Pb, Sn or metal alloys plate. A complementary set of experiments was conducted at lower temperatures, using water as melt and salted ice as plate material. These experiments scale well to the postulated prototypical conditions. The multidimensional code HAMISA, developed at RIT/NPS, is employed to analyze the experiments with good pre- and post-test predictions. The effects of melt viscosity and crust surface roughness, along with failure site entrance and exit frictional losses on the ablation characteristics are investigated. Theoretical concept was proposed to describe physical mechanisms which govern the vessel-hole ablation process during core melt discharge from RPV. Experimental data obtained from hole ablation tests and separate-effect tests performed at RIT/NPS were used to validate component physical models of the HAMISA code. It is believed that the hole ablation phenomenology is quite well understood. Detailed description of experiments and experimental data, as well as results of analyses are provided in the appendixes
Energy Technology Data Exchange (ETDEWEB)
Sun, Jian Yi; Liu, Xiao Sun; Zhang, Qing; Hong, Yan Yun; Song, Bin; Teng, Xiao Dong; Yu, Ji Ren [The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou (China)
2016-07-15
Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.
Energy Technology Data Exchange (ETDEWEB)
Sun, Jianyi; Liu, Xiaosun; Zhang, Qing; Hong, Yanyun; Song, Bin [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Teng, Xiaodong [Department of Pathology, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Yu, Jiren [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China)
2016-11-01
Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.
Energy Technology Data Exchange (ETDEWEB)
Lu, Tri-Linh, E-mail: tluonmac@gmail.com [Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Rue du Bugnon 46, 1011 Lausanne (Switzerland); Becce, Fabio; Bize, Pierre; Denys, Alban; Meuli, Reto; Schmidt, Sabine [Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Rue du Bugnon 46, 1011 Lausanne (Switzerland)
2012-09-15
Purpose: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). Materials and methods: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0 T) before (<1 month) and after RF ablation (at 1, 3 and 6 months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. Results: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n = 22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n = 20), the evolution of ADC was more complex, but with significantly higher values (p = 0.013) at 1 and 6 months after RF ablation. Conclusion: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.
Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen
2017-01-01
To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P 50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with
Guttin, Talia; Knox, Van W; Diroff, Jeremy S
2015-10-01
To describe outcomes for dogs with primary hyperparathyroidism following treatment with percutaneous ultrasound-guided ethanol ablation of presumed functional parathyroid nodules. Retrospective case series. 24 dogs with primary hyperparathyroidism that underwent 27 ultrasound-guided ethanol ablation procedures of presumed functional parathyroid nodules identified by cervical ultrasonography. Dogs were anesthetized for each procedure. For each nodule, 95% ethanol was injected into the center with ultrasound guidance (volume injected calculated on the basis of ultrasonographic measurements). The interval from treatment to resolution of hypercalcemia, complications, and follow-up clinicopathologic data were recorded. 5 procedures involved simultaneous treatment of 2 nodules. Three dogs underwent a second treatment because of initial treatment failure or development of another nodule. Hypercalcemia resolved after 23 of 27 (85%) procedures. In those 23 treatments, 22 (96%) had resolution of hypercalcemia within 72 hours after treatment. Hypocalcemia was detected in 6 different dogs at 2 (1 dog), 7 (3 dogs), 14 (1 dog), and 21 (1 dog) days after treatment; 5 of these dogs had mild transient hypocalcemia and 1 developed clinical signs requiring calcium supplementation. Although there were no periprocedural adverse effects, 2 dogs had delayed adverse effects; the overall rate of complications (including delayed adverse events and clinical hypocalcemia) was 11.1%. Long-term follow-up data indicated sustained normocalcemia in 17 of 19 dogs. Results suggested that percutaneous ultrasound-guided ethanol ablation of functional parathyroid nodules may be an effective treatment for primary hyperparathyroidism of dogs, with short duration of anesthesia, minimal complications, and low risk for hypocalcemia.
Regional brain morphometry predicts memory rehabilitation outcome after traumatic brain injury
Directory of Open Access Journals (Sweden)
Gary E Strangman
2010-10-01
Full Text Available Cognitive deficits following traumatic brain injury (TBI commonly include difficulties with memory, attention, and executive dysfunction. These deficits are amenable to cognitive rehabilitation, but optimally selecting rehabilitation programs for individual patients remains a challenge. Recent methods for quantifying regional brain morphometry allow for automated quantification of tissue volumes in numerous distinct brain structures. We hypothesized that such quantitative structural information could help identify individuals more or less likely to benefit from memory rehabilitation. Fifty individuals with TBI of all severities who reported having memory difficulties first underwent structural MRI scanning. They then participated in a 12 session memory rehabilitation program emphasizing internal memory strategies (I-MEMS. Primary outcome measures (HVLT, RBMT were collected at the time of the MRI scan, immediately following therapy, and again at one month post-therapy. Regional brain volumes were used to predict outcome, adjusting for standard predictors (e.g., injury severity, age, education, pretest scores. We identified several brain regions that provided significant predictions of rehabilitation outcome, including the volume of the hippocampus, the lateral prefrontal cortex, the thalamus, and several subregions of the cingulate cortex. The prediction range of regional brain volumes were in some cases nearly equal in magnitude to prediction ranges provided by pretest scores on the outcome variable. We conclude that specific cerebral networks including these regions may contribute to learning during I-MEMS rehabilitation, and suggest that morphometric measures may provide substantial predictive value for rehabilitation outcome in other cognitive interventions as well.
Liang, Ja-Der; Ping, Xiao-Ou; Tseng, Yi-Ju; Huang, Guan-Tarn; Lai, Feipei; Yang, Pei-Ming
2014-12-01
Recurrence of hepatocellular carcinoma (HCC) is an important issue despite effective treatments with tumor eradication. Identification of patients who are at high risk for recurrence may provide more efficacious screening and detection of tumor recurrence. The aim of this study was to develop recurrence predictive models for HCC patients who received radiofrequency ablation (RFA) treatment. From January 2007 to December 2009, 83 newly diagnosed HCC patients receiving RFA as their first treatment were enrolled. Five feature selection methods including genetic algorithm (GA), simulated annealing (SA) algorithm, random forests (RF) and hybrid methods (GA+RF and SA+RF) were utilized for selecting an important subset of features from a total of 16 clinical features. These feature selection methods were combined with support vector machine (SVM) for developing predictive models with better performance. Five-fold cross-validation was used to train and test SVM models. The developed SVM-based predictive models with hybrid feature selection methods and 5-fold cross-validation had averages of the sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the ROC curve as 67%, 86%, 82%, 69%, 90%, and 0.69, respectively. The SVM derived predictive model can provide suggestive high-risk recurrent patients, who should be closely followed up after complete RFA treatment. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Chronic Kidney Disease – Where Next? Predicting Outcomes and Planning Care Pathways
Directory of Open Access Journals (Sweden)
Angharad Marks
2014-07-01
Full Text Available With the introduction of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative chronic kidney disease (CKD guidelines, CKD has been identified as common, particularly in the elderly. The outcomes for those with CKD can be poor: mortality, initiation of renal replacement therapy, and progressive deterioration in kidney function, with its associated complications. In young people with CKD, the risk of poor outcome is high and the social cost substantial, but the actual number of patients affected is relatively small. In the elderly, the risk of poor outcome is substantially lower, but due to the high prevalence of CKD the actual number of poor outcomes attributable to CKD is higher. Predicting which patients are at greatest risk, and being able to tailor care appropriately, has significant potential benefits. Risk prediction models in CKD are being developed and show promise but thus far have limitations. In this review we describe the pathway for developing and evaluating risk prediction tools, and consider what models we have for CKD prediction and where next.
Predicting outcome from coma : man-in-the-barrel syndrome as potential pitfall
Elting, JW; Haaxma, R; De Keyser, J; Sulter, G.
The Glasgow coma scale motor score is often used in predicting outcome after hypoxic ischemic coma. Judicious care should be exerted when using this variable in predicting outcome in patients with coma following hypotension since borderzone infarction can obscure the clinical picture. We describe a
Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P
1995-01-01
Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.
Brooks, David; Parr, Adam; Bryceson, William
2018-04-01
Morton's neuroma is a common cause of forefoot pain. Outcomes of conservative therapy are mixed and many patients undergo operative intervention. Radiofrequency ablation has recently gained favor as a treatment option, although the optimal regime is unknown. This study investigates the effectiveness of 2 versus 3 cycles of radiofrequency ablation for the treatment of Morton's neuroma. We surveyed a cohort of patients with Morton's neuroma who had progressed to radiofrequency ablation after failed conservative treatment. Patients received either 2 or 3 cycles of radiofrequency ablation by a single surgeon. We assessed patients based on their change in numerical pain rating scale, symptom improvement, complications, and progression to surgical excision through a series of telephone interviews. Outcomes between the 2 treatment arms were compared by parametric tests. Twenty-eight patients were included in the study. Eighteen patients with 21 neuromas received 2 cycles and 10 patients with 11 neuromas received 3 cycles. Mean time of follow-up was 12.9 months. Overall, 88% of patients were either very or moderately satisfied with their outcome. In patients who received 2 cycles mean numerical pain scores decreased from 7.9 ± 1.1 to 3.4 ± 2.4 postprocedure. Three patients progressed to operative excision. In patients who received 3 cycles, numerical pain scores decreased from 8.0 ± 1.0 to 1.5 ± 2.0 postprocedure. One patient progressed to operative excision. Patients who received 3 cycles had reduced medium-term pain postoperatively compared with 2 cycles (3.4 ± 2.4 vs 1.5 ± 2.0, P = .011). Radiofrequency ablation provides a high rate of patient satisfaction in the treatment of Morton's neuroma with few side effects. It appears that 3 cycles may be superior to 2 cycles but a randomized controlled trial will be required to confirm these results. Intervention, Level III: Comparative study without concurrent controls.
Energy Technology Data Exchange (ETDEWEB)
Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Hong, Jun Hyung; Lim, Hyo Soon; Seon, Hyun Ju; Hur, Young Hoe; Park, Chang Hwan; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of)
2015-12-15
Ultrasound-guided percutaneous radiofrequency (RF) ablation has become one of the most promising local cancer therapies for both resectable and nonresectable hepatic tumors. Although RF ablation is a safe and effective technique for the treatment of liver tumors, the outcome of treatment can be closely related to the location and shape of the tumors. There may be difficulties with RF ablation of tumors that are adjacent to large vessels or extrahepatic heat-vulnerable organs and tumors in the caudate lobe, possibly resulting in major complications or treatment failure. Thus, a number of strategies have been developed to overcome these challenges, which include artificial ascites, needle track ablation, fusion imaging guidance, parallel targeting, bypass targeting, etc. Operators need to use the right strategy in the right situation to avoid the possibility of complications and incomplete thermal tissue destruction; with the right strategy, RF ablation can be performed successfully, even for hepatic tumors in high-risk locations. This article offers technical strategies that can be used to effectively perform RF ablation as well as to minimize possible complications related to the procedure with representative cases and schematic illustrations.
Developing a risk prediction model for the functional outcome after hip arthroscopy.
Stephan, Patrick; Röling, Maarten A; Mathijssen, Nina M C; Hannink, Gerjon; Bloem, Rolf M
2018-04-19
Hip arthroscopic treatment is not equally beneficial for every patient undergoing this procedure. Therefore, the purpose of this study was to develop a clinical prediction model for functional outcome after surgery based on preoperative factors. Prospective data was collected on a cohort of 205 patients having undergone hip arthroscopy between 2011 and 2015. Demographic and clinical variables and patient reported outcome (PRO) scores were collected, and considered as potential predictors. Successful outcome was defined as either a Hip Outcome Score (HOS)-ADL score of over 80% or improvement of 23%, defined by the minimal clinical important difference, 1 year after surgery. The prediction model was developed using backward logistic regression. Regression coefficients were converted into an easy to use prediction rule. The analysis included 203 patients, of which 74% had a successful outcome. Female gender (OR: 0.37 (95% CI 0.17-0.83); p = 0.02), pincer impingement (OR: 0.47 (95% CI 0.21-1.09); p = 0.08), labral tear (OR: 0.46 (95% CI 0.20-1.06); p = 0.07), HOS-ADL score (IQR OR: 2.01 (95% CI 0.99-4.08); p = 0.05), WHOQOL physical (IQR OR: 0.43 (95% CI 0.22-0.87); p = 0.02) and WHOQOL psychological (IQR OR: 2.40 (95% CI 1.38-4.18); p = prediction model of successful functional outcome 1 year after hip arthroscopy. The model's discriminating accuracy turned out to be fair, as 71% (95% CI: 64-80%) of the patients were classified correctly. The developed prediction model can predict the functional outcome of patients that are considered for a hip arthroscopic intervention, containing six easy accessible preoperative risk factors. The model can be further improved trough external validation and/or adding additional potential predictors.
Desorption/ablation of lithium fluoride induced by extreme ultraviolet laser radiation
Directory of Open Access Journals (Sweden)
Blejchař Tomáš
2016-06-01
Full Text Available The availability of reliable modeling tools and input data required for the prediction of surface removal rate from the lithium fluoride targets irradiated by the intense photon beams is essential for many practical aspects. This study is motivated by the practical implementation of soft X-ray (SXR or extreme ultraviolet (XUV lasers for the pulsed ablation and thin film deposition. Specifically, it is focused on quantitative description of XUV laser-induced desorption/ablation from lithium fluoride, which is a reference large band-gap dielectric material with ionic crystalline structure. Computational framework was proposed and employed here for the reconstruction of plume expansion dynamics induced by the irradiation of lithium fluoride targets. The morphology of experimentally observed desorption/ablation craters were reproduced using idealized representation (two-zone approximation of the laser fluence profile. The calculation of desorption/ablation rate was performed using one-dimensional thermomechanic model (XUV-ABLATOR code taking into account laser heating and surface evaporation of the lithium fluoride target occurring on a nanosecond timescale. This step was followed by the application of two-dimensional hydrodynamic solver for description of laser-produced plasma plume expansion dynamics. The calculated plume lengths determined by numerical simulations were compared with a simple adiabatic expansion (blast-wave model.
Directory of Open Access Journals (Sweden)
Jörg Wiltink
Full Text Available Little is known about patient characteristics as predictors for outcome in manualized short term psychodynamic psychotherapy (PDT. No study has addressed which patient variables predict outcome of PDT for social anxiety disorder.In the largest multicenter trial on psychotherapy of social anxiety (SA to date comparing cognitive therapy, PDT and wait list condition N = 230 patients were assigned to receive PDT, of which N = 166 completed treatment. Treatment outcome was assessed based on diverse parameters such as endstate functioning, remission, response, and drop-out. The relationship between patient characteristics (demographic variables, mental co-morbidity, personality, interpersonal problems and outcome was analysed using logistic and linear regressions.Pre-treatment SA predicted up to 39 percent of variance of outcome. Only few additional baseline characteristics predicted better treatment outcome (namely, lower comorbidity and interpersonal problems with a limited proportion of incremental variance (5.5 to 10 percent, while, e.g., shame, self-esteem or harm avoidance did not.We argue that the central importance of pre-treatment symptom severity for predicting outcomes should advocate alternative treatment strategies (e.g. longer treatments, combination of psychotherapy and medication in those who are most disturbed. Given the relatively small amount of variance explained by the other patient characteristics, process variables and patient-therapist interaction should additionally be taken into account in future research.Controlled-trials.com/ISRCTN53517394.
International Nuclear Information System (INIS)
Korkola, James E; Waldman, Frederic M; Blaveri, Ekaterina; DeVries, Sandy; Moore, Dan H II; Hwang, E Shelley; Chen, Yunn-Yi; Estep, Anne LH; Chew, Karen L; Jensen, Ronald H
2007-01-01
Breast cancer is a heterogeneous disease, presenting with a wide range of histologic, clinical, and genetic features. Microarray technology has shown promise in predicting outcome in these patients. We profiled 162 breast tumors using expression microarrays to stratify tumors based on gene expression. A subset of 55 tumors with extensive follow-up was used to identify gene sets that predicted outcome. The predictive gene set was further tested in previously published data sets. We used different statistical methods to identify three gene sets associated with disease free survival. A fourth gene set, consisting of 21 genes in common to all three sets, also had the ability to predict patient outcome. To validate the predictive utility of this derived gene set, it was tested in two published data sets from other groups. This gene set resulted in significant separation of patients on the basis of survival in these data sets, correctly predicting outcome in 62–65% of patients. By comparing outcome prediction within subgroups based on ER status, grade, and nodal status, we found that our gene set was most effective in predicting outcome in ER positive and node negative tumors. This robust gene selection with extensive validation has identified a predictive gene set that may have clinical utility for outcome prediction in breast cancer patients
Protein-Based Urine Test Predicts Kidney Transplant Outcomes
... News Releases News Release Thursday, August 22, 2013 Protein-based urine test predicts kidney transplant outcomes NIH- ... supporting development of noninvasive tests. Levels of a protein in the urine of kidney transplant recipients can ...
Neonatal Pulmonary MRI of Bronchopulmonary Dysplasia Predicts Short-term Clinical Outcomes.
Higano, Nara S; Spielberg, David R; Fleck, Robert J; Schapiro, Andrew H; Walkup, Laura L; Hahn, Andrew D; Tkach, Jean A; Kingma, Paul S; Merhar, Stephanie L; Fain, Sean B; Woods, Jason C
2018-05-23
Bronchopulmonary dysplasia (BPD) is a serious neonatal pulmonary condition associated with premature birth, but the underlying parenchymal disease and trajectory are poorly characterized. The current NICHD/NHLBI definition of BPD severity is based on degree of prematurity and extent of oxygen requirement. However, no clear link exists between initial diagnosis and clinical outcomes. We hypothesized that magnetic resonance imaging (MRI) of structural parenchymal abnormalities will correlate with NICHD-defined BPD disease severity and predict short-term respiratory outcomes. Forty-two neonates (20 severe BPD, 6 moderate, 7 mild, 9 non-BPD controls; 40±3 weeks post-menstrual age) underwent quiet-breathing structural pulmonary MRI (ultrashort echo-time and gradient echo) in a NICU-sited, neonatal-sized 1.5T scanner, without sedation or respiratory support unless already clinically prescribed. Disease severity was scored independently by two radiologists. Mean scores were compared to clinical severity and short-term respiratory outcomes. Outcomes were predicted using univariate and multivariable models including clinical data and scores. MRI scores significantly correlated with severities and predicted respiratory support at NICU discharge (P<0.0001). In multivariable models, MRI scores were by far the strongest predictor of respiratory support duration over clinical data, including birth weight and gestational age. Notably, NICHD severity level was not predictive of discharge support. Quiet-breathing neonatal pulmonary MRI can independently assess structural abnormalities of BPD, describe disease severity, and predict short-term outcomes more accurately than any individual standard clinical measure. Importantly, this non-ionizing technique can be implemented to phenotype disease and has potential to serially assess efficacy of individualized therapies.
Density gradient effects in weakly nonlinear ablative Rayleigh-Taylor instability
International Nuclear Information System (INIS)
Wang, L. F.; Ye, W. H.; He, X. T.
2012-01-01
In this research, density gradient effects (i.e., finite thickness of ablation front effects) in ablative Rayleigh-Taylor instability (ARTI), in the presence of preheating within the weakly nonlinear regime, are investigated numerically. We analyze the weak, medium, and strong ablation surfaces which have different isodensity contours, respectively, to study the influences of finite thickness of ablation front on the weakly nonlinear behaviors of ARTI. Linear growth rates, generation coefficients of the second and the third harmonics, and coefficients of the third-order feedback to the fundamental mode are obtained. It is found that the linear growth rate which has a remarkable maximum, is reduced, especially when the perturbation wavelength λ is short and a cut-off perturbation wavelength λ c appears when the perturbation wavelength λ is sufficiently short, where no higher harmonics exists when λ c . The phenomenon of third-order positive feedback to the fundamental mode near the λ c [J. Sanz et al., Phys. Rev. Lett. 89, 195002 (2002); J. Garnier et al., Phys. Rev. Lett. 90, 185003 (2003); J. Garnier and L. Masse, Phys. Plasmas 12, 062707 (2005)] is confirmed in numerical simulations, and the physical mechanism of the third-order positive feedback is qualitatively discussed. Moreover, it is found that generations and growths of the second and the third harmonics are stabilized (suppressed and reduced) by the ablation effect. Meanwhile, the third-order negative feedback to the fundamental mode is also reduced by the ablation effect, and hence, the linear saturation amplitude (typically ∼0.2λ in our simulations) is increased significantly and therefore exceeds the classical prediction 0.1λ, especially for the strong ablation surface with a small perturbation wavelength. Overall, the ablation effect stabilizes the ARTI in the weakly nonlinear regime. Numerical results obtained are in general agreement with the recent weakly nonlinear theories and simulations
Wongcharoen, Wanwarang; Lin, Yenn-Jiang; Chung, Fa-Po; Chen, Yun-Yu; Chao, Tze-Fan; Chen, Pei-Chun; Chien, Kuo-Liong; Chen, Shih-Ann
2017-06-10
The long-term outcomes of radiofrequency catheter ablation (RFCA) in patients with Wolff-Parkinson-White syndrome (WPW) remain unclear. We investigated the impact of RFCA on the long-term risk of coronary events and mortality in WPW patients. We conducted a prospective cohort study utilizing the Taiwan National Health Insurance Research Database. Between 2000 and 2003, WPW patients with no prior coronary artery disease (CAD) history, aged over 18 years, who underwent RFCA were identified. WPW patients without RFCA were matched with propensity-score 1:4 matching for confounding coronary risk factors. The study outcomes were total mortality and coronary events. A total of 1524 matched non-ablated WPW patients (Group 1) and 381 ablated WPW patients (Group 2) were included. After a mean follow-up of 9.6 ± 2.9 and 10.3 ± 1.9 years, respectively, ablation group demonstrated a lower incidence of mortality compared with non-ablation group (17 vs. 26/1000 person-years, P < 0.001; adjusted HR: 0.57, 95% CI: 0.44-0.7). However, ablation group had a higher incidence of coronary events compared with non-ablation group (47 vs. 82/1000 person-years, P < 0.001; adjusted HR: 1.69, 95% CI: 1.4-2.04). The ablation-treated WPW patients had lower risk of total mortality but higher risk of coronary events than non-ablated WPW patients during the long-term follow-up. Coronary artery injury produced by RFCA may account for the increased risk of coronary events. Therefore, the ablation strategies to avoid coronary artery injury should be implemented. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
International Nuclear Information System (INIS)
Zhang, Jinping; Chen, Yuping; Hu, Mengning; Chen, Xianfeng
2015-01-01
In this paper, an improved three-dimensional two-temperature model for multi-pulse femtosecond laser ablation of aluminum was proposed and proved in our experiment. Aiming to achieve hole-drilling with a high ratio of depth/entrance diameter in vacuum, this model can predict the depth and radius of the drilled holes precisely when employing different laser parameters. Additionally, for multi-pulse laser ablation, we found that the laser fluence and number of pulses are the dominant parameters and the multi-pulse ablation threshold is much lower than the single-pulse one, which will help to obtain high-quality holes
Energy Technology Data Exchange (ETDEWEB)
Zhang, Jinping; Chen, Yuping, E-mail: ypchen@sjtu.edu.cn; Hu, Mengning; Chen, Xianfeng [State Key Laboratory of Advanced Optical Communication Systems and Networks, Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China)
2015-02-14
In this paper, an improved three-dimensional two-temperature model for multi-pulse femtosecond laser ablation of aluminum was proposed and proved in our experiment. Aiming to achieve hole-drilling with a high ratio of depth/entrance diameter in vacuum, this model can predict the depth and radius of the drilled holes precisely when employing different laser parameters. Additionally, for multi-pulse laser ablation, we found that the laser fluence and number of pulses are the dominant parameters and the multi-pulse ablation threshold is much lower than the single-pulse one, which will help to obtain high-quality holes.
He, Zhen-Xin; Xiang, Pu; Gong, Jian-Ping; Cheng, Nan-Sheng; Zhang, Wei
2016-01-01
To compare the long-term survival outcomes of radiofrequency ablation and liver resection for single very early/early stage hepatocellular carcinoma (HCC). The Cochrane Library (Issue 3, 2015), Embase (1974 to March 15, 2015), PubMed (1950 to March 15, 2015), Web of Science (1900 to March 15, 2015), and Chinese Biomedical Literature Database (1978 to March 15, 2015) were searched to identify relevant trials. Only trials that compared radiofrequency ablation and liver resection for single very early stage (≤2 cm) or early stage (≤3 cm) HCC according to the Barcelona clinic liver cancer (BCLC) staging system were considered for inclusion in this review. The primary outcomes that we analyzed were the 3-year and 5-year overall survival (OS) rates, and the secondary outcomes that we analyzed were the 3-year and 5-year disease-free survival (DFS) rates. Review Manager 5.3 was used to perform a cumulative meta-analysis. Possible publication bias was examined using a funnel plot. A random-effects model was applied to summarize the various outcomes. Six studies involving 947 patients were identified that compared radiofrequency ablation (n=528) to liver resection (n=419) for single BCLC very early HCC. In these six studies, the rates of 3-year OS, 5-year OS, 3-year DFS, and 5-year DFS were significantly lower in the radiofrequency ablation group than in the liver resection group (risk ratio [RR] =0.90, 95% confidence interval [CI]: 0.83-0.98, P=0.01; RR =0.84, 95% CI: 0.75-0.95, P=0.004; RR =0.77, 95% CI: 0.60-0.98, P=0.04; and RR =0.70, 95% CI: 0.52-0.94, P=0.02, respectively). Ten studies involving 2,501 patients were identified that compared radiofrequency ablation (n=1,476) to liver resection (n=1,025) for single BCLC early HCC. In these ten studies, the rates of 3-year OS, 5-year OS, 3-year DFS, and 5-year DFS were also significantly lower in the radiofrequency ablation group than in the liver resection group (RR =0.93, 95% CI: 0.88-0.98, P=0.003; RR =0.84, 95% CI
Percutaneous thermal ablation of renal neoplasms
International Nuclear Information System (INIS)
Tacke, J.; Mahnken, A.H.; Guenther, R.W.
2005-01-01
Due to modern examination techniques such as multidetector computed tomography and high-field magnetic resonance imaging, the detection rate of renal neoplasms is continually increasing. Even though tumors exceeding 4 cm in diameter rarely metastasize, all renal lesions that are possible neoplasms should be treated. Traditional treatment techniques include radical nephrectomy or nephron-sparing resection, which are increasingly performed laparoscopically. Modern thermal ablation techniques such as hyperthermal techniques like radiofrequency ablation RFA, laser induced thermal ablation LITT, focused ultrasound FUS and microwave therapy MW, as well as hypothermal techniques (cryotherapy) may be a useful treatment option for patients who are unfit for or refuse surgical resection. Cryotherapy is the oldest and best known thermal ablation technique and can be performed laparoscopically or percutaneously. Since subzero temperatures have no antistyptic effect, additional maneuvers must be performed to control bleeding. Percutaneous cryotherapy of renal tumors is a new and interesting method, but experience with it is still limited. Radiofrequency ablation is the most frequently used method. Modern probe design allows volumes between 2 and 5 cm in diameter to be ablated. Due to hyperthermal tract ablation, the procedure is deemed to be safe and has a low complication rate. Although there are no randomized comparative studies to open resection, the preliminary results for renal RFA are promising and show RFA to be superior to other thermal ablation techniques. Clinical success rates are over 90% for both, cryo- and radiofrequency ablation. Whereas laser induced thermal therapy is established in hepatic ablation, experience is minimal with respect to renal application. For lesions of more than 2 cm in diameter, additional cooling catheters are required. MR thermometry offers temperature control during ablation. Microwave ablation is characterized by small ablation volumes
Directory of Open Access Journals (Sweden)
Lee SH
2015-02-01
Full Text Available Sang Hoon Lee,1 Seung Up Kim,1–3 Jeong Won Jang,4 Si Hyun Bae,4 Sanghun Lee,1,3 Beom Kyung Kim,1–3 Jun Yong Park,1–3 Do Young Kim,1–3 Sang Hoon Ahn,1–3 Kwang–Hyub Han1–31Department of Internal Medicine, 2Institute of Gastroenterology, Yonsei University College of Medicine, 3Liver Cirrhosis Clinical Research Center, 4Department of Internal Medicine, College of Medicine, Catholic University of Korea, Seoul, KoreaBackground/purpose: Liver stiffness (LS measurement using transient elastography can accurately assess the degree of liver fibrosis, which is associated with the risk of the development of hepatocellular carcinoma (HCC. We investigated whether LS values could predict HCC de novo recurrence after radiofrequency ablation (RFA.Methods: This retrospective, multicenter study analyzed 111 patients with HCC who underwent RFA and LS measurement using transient elastography between May 2005 and April 2011. All patients were followed until March 2013 to monitor for HCC recurrence.Results: This study included 76 men and 35 women with a mean age of 62.4 years, and the mean LS value was 21.2 kPa. During the follow-up period (median 22.4 months, 47 (42.3% patients experienced HCC de novo recurrence, and 18 (16.2% died. Patients with recurrence had significantly more frequent liver cirrhosis, more frequent history of previous treatment for HCC, higher total bilirubin, larger spleen size, larger total tumor size, higher tumor number, higher LS values, and lower platelet counts than those without recurrence (all P<0.05. On multivariate analysis, together with previous anti-HCC treatment history, patients with LS values >13.0 kPa were at significantly greater risk for recurrence after RFA, with a hazard ratio (HR of 3.115 (95% confidence interval [CI], 1.238–7.842, P<0.05. Moreover, LS values independently predicted the mortality after RFA, with a HR of 9.834 (95% CI, 1.148–84.211, P<0.05, together with total bilirubin.Conclusions: Our
Mohtashami, Yahya; Luyen, Hung; Hagness, Susan C.; Behdad, Nader
2018-06-01
We present an investigation of a new class of microwave ablation (MWA) antennas capable of producing axially symmetric or asymmetric heating patterns. The antenna design is based on a dipole fed by a balanced parallel-wire transmission line. The angle and direction of the deployed dipole arms are used to control the heating pattern. We analyzed the specific absorption rate and temperature profiles using electromagnetic and thermal simulations. Two prototypes were fabricated and tested in ex vivo ablation experiments: one was designed to produce symmetric heating patterns and the other was designed to generate asymmetric heating patterns. Both fabricated prototypes exhibited good impedance matching and produced localized coagulation zones as predicted by the simulations. The prototype operating in porcine muscle created an ˜10 cm3 symmetric ablation zone after 10 min of ablation with a power level of 18 W. The prototype operating in egg white created an ˜4 cm3 asymmetric ablation zone with a directionality ratio of 40% after 5 min of ablation with a power level of 25 W. The proposed MWA antenna design shows promise for minimally invasive treatment of tumors in various clinical scenarios where, depending on the situation, a symmetric or an asymmetric heating pattern may be needed.
Neonatal Sleep-Wake Analyses Predict 18-month Neurodevelopmental Outcomes.
Shellhaas, Renée A; Burns, Joseph W; Hassan, Fauziya; Carlson, Martha D; Barks, John D E; Chervin, Ronald D
2017-11-01
The neurological examination of critically ill neonates is largely limited to reflexive behavior. The exam often ignores sleep-wake physiology that may reflect brain integrity and influence long-term outcomes. We assessed whether polysomnography and concurrent cerebral near-infrared spectroscopy (NIRS) might improve prediction of 18-month neurodevelopmental outcomes. Term newborns with suspected seizures underwent standardized neurologic examinations to generate Thompson scores and had 12-hour bedside polysomnography with concurrent cerebral NIRS. For each infant, the distribution of sleep-wake stages and electroencephalogram delta power were computed. NIRS-derived fractional tissue oxygen extraction (FTOE) was calculated across sleep-wake stages. At age 18-22 months, surviving participants were evaluated with Bayley Scales of Infant Development (Bayley-III), 3rd edition. Twenty-nine participants completed Bayley-III. Increased newborn time in quiet sleep predicted worse 18-month cognitive and motor scores (robust regression models, adjusted r2 = 0.22, p = .007, and 0.27, .004, respectively). Decreased 0.5-2 Hz electroencephalograph (EEG) power during quiet sleep predicted worse 18-month language and motor scores (adjusted r2 = 0.25, p = .0005, and 0.33, .001, respectively). Predictive values remained significant after adjustment for neonatal Thompson scores or exposure to phenobarbital. Similarly, an attenuated difference in FTOE, between neonatal wakefulness and quiet sleep, predicted worse 18-month cognitive, language, and motor scores in adjusted analyses (each p sleep-as quantified by increased time in quiet sleep, lower electroencephalogram delta power during that stage, and muted differences in FTOE between quiet sleep and wakefulness-may improve prediction of adverse long-term outcomes for newborns with neurological dysfunction. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved
Low plasma bicarbonate predicts poor outcome of cerebral malaria ...
African Journals Online (AJOL)
Malaria remains a major cause of morbidity and mortality in many sub Saharan countries and cerebral malaria is widely recognised as one of its most fatal forms. We studied the predictive value of routine biochemical laboratory indices in predicting the outcome of cerebral malaria in 50 Nigerian children ages 9 months to 6 ...
Squara, F; Theodore, G; Scarlatti, D; Ferrari, E
2017-02-01
We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty
Energy Technology Data Exchange (ETDEWEB)
Cepek, Jeremy, E-mail: jcepek@robarts.ca; Fenster, Aaron [Robarts Research Institute, London, Ontario N6A 5K8, Canada and Biomedical Engineering, The University of Western Ontario, London, Ontario N6A 5B9 (Canada); Lindner, Uri; Trachtenberg, John [Department of Surgical Oncology, Division of Urology, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Davidson, Sean R. H. [Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Center, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5S 2J7 (Canada); Ghai, Sangeet [Department of Medical Imaging, University Health Network, Toronto, Ontario M5G 2M9 (Canada)
2014-01-15
Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table is provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.
An experimental study on hepatic ablation using an expandable radio-frequency needle electrode
International Nuclear Information System (INIS)
Choi, Dong Il; Lim, Hyo Keun; Park, Jong Min; Kang, Bo Kyung; Woo, Ji Young; Jang, Hyun Jung; Kim, Seung Hoon; Lee, Won Jae; Park, Cheol Keun; Heo, Jin Seok
1999-01-01
The purpose of this study was to determine the factors influencing on the size of thermal lesions after ablation using an expendable radio-frequency needle electrode in porcine liver. Ablation procedures involved the use of a monopolar radio-frequency generator and 15-G needle electrodes with four and seven retractable hooks (RITA Medical System, Mountain View, Cal., U.S.A.). The ablation protocol in fresh porcine liver comprised of combinations of varying hook deployment, highest set temperature, and ablation time. Following ablation, the maximum diameter of all thermal lesions was measured on a longitudinal section of the specimen. Ten representive lesions were examined by an experienced pathologist. At 3-cm hook deployment of the needle electrode with four lateral hooks, the size of spherical thermal lesions increased substantially with increases in the highest set temperature and ablation time until 11 minutes. After 11 minutes lesion size remained similar, with a maximum diameter of 3.3 cm. At 2-cm hook deployment, sizes decreased to about 2/3 of those at 3 cm , and at 1-cm hook deployment lesions were oblong. At 3-cm hook deployment of a needle electrode with seven hooks, the size of thermal lesions increased with increasing ablation time until 14 minutes, and the maximum diameter was 4.1 cm. Microscopic examination showed a wide zone of degeneration and focal coagulation necrosis. The size of thermal lesions produced by the use of an expandable radio-frequency needle electrode were predictable, varying according to degree of hook deployment, highest set temperature, and ablation time
[Gastroschisis: Prenatal ultrasonography and obstetrical criteria for predicting neonatal outcome].
Ducellier, G; Moussy, P; Sahmoune, L; Bonneau, S; Alanio, E; Bory, J-P
2016-09-01
Prenatal diagnosis of complex laparoschisis is difficult and yet it is associated with a significantly increased morbidity and mortality. The aim of the study was to define ultrasonographic factor and obstetrical criteria to predicting adverse neonatal outcome. Retrospective cohort study over 10 years, of 35 gastroschisis cases in CHU of Reims (France). The primary outcome was the neonatal death due to gastroschisis. The sonographic markers was bowel dilatation intra- or extra-abdominale, amniotic fluid, intra-uterin growth. The obstetrical criteria was fetal vitality, fetal heart rate, type of delivery, the weight and the term of birth. There were 28 live births, 16 children with favorable outcome, 8 children with adverse perinatal outcome and 4 deaths. There were any sonographic criteria to predicting adverse neonatal outcome. Only the birth weight less than 2000g was associated with an increase gastrointestinal complications (P=0.049). The type of the delivery was not associated with an adverse prenatal outcome. The birth weight less than 2000g seems to be associate with an increase gastrointestinal complications. It is important to fight against prematurity in case of gastroschisis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Stojanovska, Jadranka; Kazerooni, Ella A.; Gross, Barry H.; Patel, Smita [University of Michigan Health System, Department of Radiology, Division of Cardiothoracic Radiology, UH B1-132 Taubman/Box 0302, Ann Arbor, MI (United States); Sinno, Mohamad; Oral, Hakan [University of Michigan Health System, Department of Internal Medicine, Cardiovascular Medicine, Electrophysiology Laboratory, Cardiovascular Center, Ann Arbor, MI (United States); Watcharotone, Kuanwong [University of Michigan, Michigan Institute for Clinical and Health Research (MICHR), Ann Arbor, MI (United States); Jacobson, Jon A. [University of Michigan Health System, Department of Radiology, Division of Musculoskeletal Radiology, Ann Arbor, MI (United States)
2015-08-15
To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 non-paroxysmal and 94 paroxysmal) and 62 control patients underwent cardiac CT examination. Extrapericardial (EPFV) and epicardial fat volumes (EFV) were measured on CT, the sum of which is the total intrathoracic fat volume. Associations between these three fat volumes and presence and chronicity of AF, and outcome after RFA, were evaluated using logistic regression analysis. EFV was significantly associated with presence [OR 1.01 (95 % CI 1.003-1.03), p = 0.01], chronicity of AF [1.008 (1.001-1.020), p = 0.03] and AF recurrence after RFA [1.009 (1.001-1.01), p = 0.02] after adjustment for age, gender and BMI. Patients with a larger EFV had a shorter time to AF recurrence (p = 0.017) and a higher rate of recurrence (54 % vs 46 %) (p = 0.002) after RFA. EPFV had no significant associations. Increased epicardial fat is associated with the presence and chronicity of AF, a higher probability of AF recurrence after RFA and a shorter AF-free interval. (orig.)
Computational Tool for Coupled Simulation of Nonequilibrium Hypersonic Flows with Ablation, Phase I
National Aeronautics and Space Administration — The goal of this SBIR project is to develop a computational tool with unique predictive capabilities for the aerothermodynamic environment around ablation-cooled...
Computational Tool for Coupled Simulation of Nonequilibrium Hypersonic Flows with Ablation, Phase II
National Aeronautics and Space Administration — The goal of this SBIR project is to develop a predictive computational tool for the aerothermal environment around ablation-cooled hypersonic atmospheric entry...
International Nuclear Information System (INIS)
Sergeev, V. Yu.; Bakhareva, O. A.; Kuteev, B. V.; Tendler, M.
2006-01-01
The ablation of impurity pellets in tokamak and stellarator plasmas is investigated. Different mechanisms for shielding the heat fluxes from the surrounding plasma to the pellet surface are discussed. A model for impurity pellet ablation is developed that can account for both neutral and electrostatic shielding. It is shown that the experimental values of the impurity pellet ablation rate are well described by the neutral gas shielding model over a wide range of plasma temperatures and densities. Taking into account the electrostatic shielding leads to worse agreement between the predictions of the model and the experimental data; this result still remains unclear. Scaling laws are obtained that allow one to estimate the local ablation rate of impurity pellets made of various materials over a wide range of plasma parameters in the neutral gas shielding model
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year Update
Solbiati, Luigi; Brace, Christopher L.; Breen, David J.; Callstrom, Matthew R.; Charboneau, J. William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D.; Dupuy, Damian E.; Gervais, Debra A.; Gianfelice, David; Gillams, Alice R.; Lee, Fred T.; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J.; Livraghi, Tito; Lu, David S.; McGahan, John P.; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L.; Liang, Ping; Rhim, Hyunchul; Rose, Steven C.; Salem, Riad; Sofocleous, Constantinos T.; Solomon, Stephen B.; Soulen, Michael C.; Tanaka, Masatoshi; Vogl, Thomas J.; Wood, Bradford J.; Goldberg, S. Nahum
2014-01-01
Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. © RSNA, 2014 Online supplemental material is available for this article. PMID:24927329
Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?
Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe
2016-03-01
Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Perioral Rejuvenation With Ablative Erbium Resurfacing.
Cohen, Joel L
2015-11-01
Since the introduction of the scanning full-field erbium laser, misconceptions regarding ablative erbium resurfacing have resulted in its being largely overshadowed by ablative fractional resurfacing. This case report illustrates the appropriateness of full-field erbium ablation for perioral resurfacing. A patient with profoundly severe perioral photodamage etched-in lines underwent full-field ablative perioral resurfacing with an erbium laser (Contour TRL, Sciton Inc., Palo Alto, CA) that allows separate control of ablation and coagulation. The pre-procedure consultations included evaluation of the severity of etched-in lines, and discussion of patient goals, expectations, and appropriate treatment options, as well as a review of patient photos and post-treatment care required. The author generally avoids full-field erbium ablation in patients with Fitzpatrick type IV and above. For each of 2 treatment sessions (separated by approximately 4 months), the patient received (12 cc plain 2% lidodaine) sulcus blocks before undergoing 4 passes with the erbium laser at 150 μ ablation, no coagulation, and then some very focal 30 μ ablation to areas of residual lines still visualized through the pinpoint bleeding. Similarly, full-field ablative resurfacing can be very reliable for significant wrinkles and creping in the lower eyelid skin--where often a single treatment of 80 μ ablation, 50 μ coagulation can lead to a nice improvement. Standardized digital imaging revealed significant improvement in deeply etched rhytides without significant adverse events. For appropriately selected patients requiring perioral (or periorbital) rejuvenation, full-field ablative erbium resurfacing is safe, efficacious and merits consideration.
Predicting the Outcome of NBA Playoffs Based on the Maximum Entropy Principle
Ge Cheng; Zhenyu Zhang; Moses Ntanda Kyebambe; Nasser Kimbugwe
2016-01-01
Predicting the outcome of National Basketball Association (NBA) matches poses a challenging problem of interest to the research community as well as the general public. In this article, we formalize the problem of predicting NBA game results as a classification problem and apply the principle of Maximum Entropy to construct an NBA Maximum Entropy (NBAME) model that fits to discrete statistics for NBA games, and then predict the outcomes of NBA playoffs using the model. Our results reveal that...
Ischemic stroke associated with radio frequency ablation for nodal reentry
International Nuclear Information System (INIS)
Diaz M, Juan C; Duran R, Carlos E; Perafan B, Pablo; Pava M, Luis F
2010-01-01
Atrioventricular nodal reentry tachycardia is the most common type of paroxysmal supraventricular tachycardia. In those patients in whom drug therapy is not effective or not desired, radio frequency ablation is an excellent therapeutic method. Although overall these procedures are fast and safe, several complications among which ischemic stroke stands out, have been reported. We present the case of a 41 year old female patient with repetitive episodes of tachycardia due to nodal reentry who was treated with radiofrequency ablation. Immediately after the procedure she presented focal neurologic deficit consistent with ischemic stroke in the right medial cerebral artery territory. Angiography with angioplastia and abxicimab was performed and then tissue plasminogen activator (rtPA) was locally infused, with appropriate clinical and angiographic outcome.
Comparing 2 Whiplash Grading Systems to Predict Clinical Outcomes.
Croft, Arthur C; Bagherian, Alireza; Mickelsen, Patrick K; Wagner, Stephen
2016-06-01
Two whiplash severity grading systems have been developed: Quebec Task Force on Whiplash-Associated Disorders (QTF-WAD) and the Croft grading system. The majority of clinical studies to date have used the modified grading system published by the QTF-WAD in 1995 and have demonstrated some ability to predict outcome. But most studies include only injuries of lower severity (grades 1 and 2), preventing a broader interpretation. The purpose of this study was assess the ability of these grading systems to predict clinical outcome within the context of a broader injury spectrum. This study evaluated both grading systems for their ability to predict the bivalent outcome, recovery, within a sample of 118 whiplash patients who were part of a previous case-control designed study. Of these, 36% (controls) had recovered, and 64% (cases) had not recovered. The discrete bivariate distribution between recovery status and whiplash grade was analyzed using the 2-tailed cross-tabulation statistics. Applying the criteria of the original 1993 Croft grading system, the subset comprised 1 grade 1 injury, 32 grade 2 injuries, 53 grade 3 injuries, and 32 grade 4 injuries. Applying the criteria of the modified (QTF-WAD) grading system, there were 1 grade 1 injury, 89 grade 2 injuries, and 28 grade 3 injuries. Both whiplash grading systems correlated negatively with recovery; that is, higher severity grades predicted a lower probability of recovery, and statistically significant correlations were observed in both, but the Croft grading system substantially outperformed the QTF-WAD system on this measure. The Croft grading system for whiplash injury severity showed a better predictive measure for recovery status from whiplash injuries as compared with the QTF-WAD grading system.
Energy Technology Data Exchange (ETDEWEB)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Lemm, G.; Hohenstein, E. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany); Bellemann, N.; Stampfl, U. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Goezen, A. S.; Rassweiler, J. [Clinic for Urology, SLK Kliniken Heilbronn GmbH (Germany); Kauczor, H. U.; Radeleff, B. A. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Pereira, P. L. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany)
2013-06-15
Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 {+-} 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 {+-} 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 {+-} 13.6 min and 43.7 {+-} 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 {+-} 8.8 months, local recurrence-free survival was 14.4 {+-} 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 {+-} 16.6 ml/min/1.73 m{sup 2} before RF ablation vs. 47.2 {+-} 11.9 ml/min/1.73 m{sup 2} after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.
Yoshiga, Yasuhiro; Shimizu, Akihiko; Ueyama, Takeshi; Ono, Makoto; Fukuda, Masakazu; Fumimoto, Tomoko; Ishiguchi, Hironori; Omuro, Takuya; Kobayashi, Shigeki; Yano, Masafumi
2018-08-01
An effective catheter ablation strategy, beyond pulmonary vein isolation (PVI), for persistent atrial fibrillation (AF) is necessary. Pulmonary vein (PV)-reconduction also causes recurrent atrial tachyarrhythmias. The effect of the PVI and additional effect of a superior vena cava (SVC) isolation (SVCI) was strictly evaluated. Seventy consecutive patients with persistent AF who underwent a strict sequential ablation strategy targeting the PVs and SVC were included in this study. The initial ablation strategy was a circumferential PVI. A segmental SVCI was only applied as a repeat procedure when patients demonstrated no PV-reconduction. After the initial procedure, persistent AF was suppressed in 39 of 70 (55.7%) patients during a median follow-up of 32 months. After multiple procedures, persistent AF was suppressed in 46 (65.7%) and 52 (74.3%) patients after receiving the PVI alone and PVI plus SVCI strategies, respectively. In 6 of 15 (40.0%) patients with persistent AF resistant to PVI, persistent AF was suppressed. The persistent AF duration independently predicted persistent AF recurrences after multiple PVI alone procedures [HR: 1.012 (95% confidence interval: 1.006-1.018); pstrategies [HR: 1.018 (95% confidence interval: 1.011-1.025); pstrategies, respectively. The outcomes of the PVI plus SVCI strategy were favorable for patients with shorter persistent AF durations. The initial SVCI had the additional effect of maintaining sinus rhythm in some patients with persistent AF resistant to PVI. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Comparison of TMS and DTT for predicting motor outcome in intracerebral hemorrhage.
Jang, Sung Ho; Ahn, Sang Ho; Sakong, Joon; Byun, Woo Mok; Choi, Byung Yun; Chang, Chul Hoon; Bai, Daiseg; Son, Su Min
2010-03-15
TMS (transcranial magnetic stimulation) and DTT (diffusion tensor tractography) have different advantages in evaluating stroke patients. TMS has good clinical accessibility and economical benefit. On the contrary, DTT has a unique advantage to visualize neural tracts three-dimensionally although it requires an expensive and large MRI machine. Many studies have demonstrated that TMS and DTT have predictive values for motor outcome in stroke patients. However, there has been no study on the comparison of these two evaluation tools. In the current study, we compared the abilities of TMS and DTT to predict upper motor outcome in patients with ICH (intracerebral hemorrhage). Fifty-three consecutive patients with severe motor weakness were evaluated by TMS and DTT at the early stage (7-28 days) of ICH. Modified Brunnstrom classification (MBC) and the motricity index of upper extremity (UMI) were evaluated at onset and 6 months after onset. Patients with the presence of a motor evoked potential (MEP) in TMS or a preserved corticospinal tract (CST) in DTT showed better motor outcomes than those without (p=0.000). TMS showed higher positive predictive value than DTT. In contrast, DTT showed higher negative predictive value than TMS. TMS and DTT had different advantages in predicting motor outcome, and this result could be a reference to predict final neurological deficit at the early stage of ICH.
Endovenous laser ablation (EVLA): a review of mechanisms, modeling outcomes, and issues for debate
W.S.J. Malskat (Wendy S.); A.A. Poluektova (Anna); C.W.M. van der Geld (Cees); H.A.M. Neumann (Martino); R.A. Weiss (Robert); C.M.A. Bruijninckx; M.J.C. van Gemert (Martin)
2013-01-01
textabstractEndovenous laser ablation (EVLA) is a commonly used and very effective minimally invasive therapy to manage leg varicosities. Yet, and despite a clinical history of 16 years, no international consensus on a best treatment protocol has been reached so far. Evidence presented in this paper
Looking for students'personal characteristics predicting study outcome
Bergen, T.C.M.; Bragt, van C.A.C.; Bakx, A.W.E.A.; Croon, M.A.
2011-01-01
Abstract The central goal of this study is to clarify to what degree former education and students’ personal characteristics (the ‘Big Five personality characteristics’, personal orientations on learning and students’ study approach) may predict study outcome (required credits and study
Looking for students' personal characteristics predicting study outcome.
Dr. A. Bakx; Theo Bergen; Dr. Cyrille A.C. Van Bragt; Marcel Croon
2011-01-01
Abstract The central goal of this study is to clarify to what degree former education and students' personal characteristics (the 'Big Five personality characteristics', personal orientations on learning and students' study approach) may predict study outcome (required credits and study
X-ray ablation measurements and modeling for ICF applications
International Nuclear Information System (INIS)
Anderson, A.T.
1996-09-01
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. Experiments have been conducted at the Nova laser on the effects of relevant x-ray fluences on various materials. The response was diagnosed using post-shot examinations of the surfaces with scanning electron microscope and atomic force microscope instruments. Judgments were made about the dominant removal mechanisms for each material. Measurements of removal depths were made to provide data for the modeling. The finite difference ablation code developed here (ABLATOR) combines the thermomechanical response of materials to x-rays with models of various removal mechanisms. The former aspect refers to energy deposition in such small characteristic depths (∼ micron) that thermal conduction and hydrodynamic motion are significant effects on the nanosecond time scale. The material removal models use the resulting time histories of temperature and pressure-profiles, along with ancillary local conditions, to predict rates of surface vaporization and the onset of conditions that would lead to spallation
Water spray assisted ultrashort laser pulse ablation
International Nuclear Information System (INIS)
Silvennoinen, M.; Kaakkunen, J.J.J.; Paivasaari, K.; Vahimaa, P.
2013-01-01
Highlights: ► We show the novel method to use multibeam processing with ultrashort pulses efficiently. ► Sprayed thin water layer on ablation zone enhances ablation rate and quality. ► In some cases this method also enables ablation of the deeper and straighter holes compared to ones made without the water layer. ► Method also makes possible to directly write features without the self-organizing structures. - Abstract: We have studied femtosecond ablation under sprayed thin water film and its influence and benefits compared with ablation in the air atmosphere. These have been studied in case of the hole and the groove ablation using IR femtosecond laser. Water enhances the ablation rate and in some situations it makes possible to ablate the holes with a higher aspect ratio. While ablating the grooves, the water spray allows using the high fluences without the generation of the self-organized structures.
International Nuclear Information System (INIS)
Kim, Young Sun; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Joo, Kyoung Bin
2001-01-01
To assess the effect of ethanol infusion on the size of ablated lesion during radiofrequency (RF) thermal ablation. We performed an ex vivo experimental study using a total of 15 pig livers. Three groups were designed: 1)normal control (n=10), 2) saline infusion (n=10) 3) ethanol infusion (n=10). Two radiofrequency ablations were done using a 50 watt RF generator and a 15 guage expandable elections with four prongs in each liver. During ablation for 8 minutes, continuous infusion of fluid at a rate of 0.5 ml/min through the side arm of electrode was performed. We checked the frequency of the 'impeded-out' phenomenon due to abrupt increase of impedance during ablation. Size of ablated lesion was measured according to length, width, height, and subsequently volume after the ablations. The sizes of the ablated lesions were compared between the three groups. 'Impeded-out' phenomenon during ablation was noted 4 times in control group, although that never happened in saline or ethanol infusion groups. There were significant differences in the volumes of ablated lesions between control group (10.62 ± 1.45 cm 3 ) and saline infusion group (15.33 ± 2.47 cm 3 ), and saline infusion group and ethanol infusion group (18.78 ± 3.58 cm 3 ) (p<0.05). Fluid infusion during radiofrequency thermal ablation decrease a chance of charming and increase the volume of the ablated lesion. Ethanol infusion during ablation may induce larger volume of ablated lesion than saline infusion.
Predictive value of cognition for different domains of outcome in recent-onset schizophrenia.
Holthausen, Esther A E; Wiersma, Durk; Cahn, Wiepke; Kahn, René S; Dingemans, Peter M; Schene, Aart H; van den Bosch, Robert J
2007-01-15
The aim of this study was to see whether and how cognition predicts outcome in recent-onset schizophrenia in a large range of domains such as course of illness, self-care, interpersonal functioning, vocational functioning and need for care. At inclusion, 115 recent-onset patients were tested on a cognitive battery and 103 patients participated in the follow-up 2 years after inclusion. Differences in outcome between cognitively normal and cognitively impaired patients were also analysed. Cognitive measures at inclusion did not predict number of relapses, activities of daily living and interpersonal functioning. Time in psychosis or in full remission, as well as need for care, were partly predicted by specific cognitive measures. Although statistically significant, the predictive value of cognition with regard to clinical outcome was limited. There was a significant difference between patients with and without cognitive deficits in competitive employment status and vocational functioning. The predictive value of cognition for different social outcome domains varies. It seems that cognition most strongly predicts work performance, where having a cognitive deficit, regardless of the nature of the deficit, acts as a rate-limiting factor.
Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laser
Arbelaez, María Clara; Vidal, Camila; Arba Mosquera, Samuel
2011-01-01
Purpose To evaluate postoperative clinical outcomes, and corneal High Order Aberrations, among eyes with hyperopia up to +5 D of spherical equivalent, that have undergone LASIK treatments using the SCHWIND AMARIS laser system. Methods At six-month follow-up, 100 eyes with preoperative hyperopia or hyperopic astigmatism up to +5 D of spherical equivalent were retrospectively analysed. Standard examinations, pre- and postoperative wavefront analysis with a corneal-wavefront-analyzer (OPTIKON Scout) were performed. Aberration-Free aspheric treatments were planned with Custom Ablation Manager software and ablations performed using the SCHWIND AMARIS flying-spot excimer laser system (both SCHWIND eye-tech-solutions). LASIK flaps were created using a LDV femtosecond laser (Ziemer Group) in all cases. Clinical outcomes were evaluated in terms of predictability, refractive outcome, safety, and wavefront aberration. Results At six month, 90 % of eyes achieved ≥ 20/25 UCVA and 44 % achieved ≥ 20/16 UCVA. Seventy-four percent of eyes were within ± 0.25D of spherical equivalent and 89 % within ± 0.50D, with 94 % within 0.50D of astigmatism. Mean spherical equivalent was −0.12 ± 0.51D and 0.50 ± 0.51D for the astigmatism. Fifty-two percent of eyes improved BSCVA vs. only 19 % losing lines of BSCVA. Predictability slope for refraction was 1.03 and intercept +0.01 D. On average, negative corneal spherical aberrations were significantly increased by the treatments, no other aberration terms changed from pre- to postoperative values. Conclusions LASIK for hyperopia and hyperopic astigmatism with SCHWIND AMARIS yields very satisfactory visual outcomes. Preoperative refractions were postoperatively reduced to subclinical values with no clinically relevant induction of corneal HOA.
Engelke, W. T.; Robertson, R. W.; Bush, A. L.; Pears, C. D.
1974-01-01
An evaluation of the thermal and mechanical properties was performed on a molded low-density elastomeric ablation material designated as Material B. Both the virgin and charred states were examined to provide meaningful inputs to the design of a thermal protection system. Chars representative of the flight chars formed during ablation were prepared in a laboratory furnace from 600 K to 1700 K and properties of effective thermal conductivity, heat capacity, porosity and permeability were determined on the furnace chars formed at various temperature levels within the range. This provided a boxing of the data which will enable the prediction of the transient response of the material during flight ablation.
Predicting the Outcome of NBA Playoffs Based on the Maximum Entropy Principle
Directory of Open Access Journals (Sweden)
Ge Cheng
2016-12-01
Full Text Available Predicting the outcome of National Basketball Association (NBA matches poses a challenging problem of interest to the research community as well as the general public. In this article, we formalize the problem of predicting NBA game results as a classification problem and apply the principle of Maximum Entropy to construct an NBA Maximum Entropy (NBAME model that fits to discrete statistics for NBA games, and then predict the outcomes of NBA playoffs using the model. Our results reveal that the model is able to predict the winning team with 74.4% accuracy, outperforming other classical machine learning algorithms that could only afford a maximum prediction accuracy of 70.6% in the experiments that we performed.
International Nuclear Information System (INIS)
Zheng, J.-S.; Long, J.; Sun, B.; Lu, N.-N.; Fang, D.; Zhao, L.-Y.; Du, N.
2014-01-01
Aim: To retrospectively assess long-term survival benefit and safety of transcatheter arterial chemoembolization (TACE) combined with radiofrequency ablation (RFA) in hepatocellular carcinoma (HCC) patients with portal vein tumour thrombosis (PVTT), and to evaluate factors that significantly affect outcomes of these patients. Materials and methods: One hundred and thirty-four HCC patients (118 men and 16 women; mean age 54.8 years, range 26–79 years) with PVTT were retrospectively assessed. Patients were treated with TACE combined with RFA. Data analysed included patient demographics, liver volume, Child–Pugh score, and Cancer of the Liver Italian Programme (CLIP) score and imaging findings. Survival time (from occurrence of PVTT to last follow-up) was calculated using the Kaplan–Meier method, predictive factors and its correlation with survival was assessed using the multivariate Cox proportional hazards regression method. Results: The median overall survival (OS) time was 29.5 months (range 16.6–42.4 months), the 1, 3, and 5 year OS were 63%, 40%, and 23%. Cox hazards regression analysis revealed that functional remnant liver volume (FRLV), remnant liver volume (RLV)/total liver volume (TLV), radiation, tumour number, vascular endothelial growth factor (VEGF) distribution, and gross type were the only independent predictive factors of outcome (p = 0.039, 0.010, 0.009, 0.034, 0.031, and 0.000, respectively). Conclusion: TACE combined with RFA was found to be an effective therapy, FRLV and RLV/TLV have close correlation with survival for HCC patients with PVTT type I, II, or partial III and Child–Pugh A or B
Is the AIMS65 score useful in predicting outcomes in peptic ulcer bleeding?
Jung, Sung Hoon; Oh, Jung Hwan; Lee, Hye Yeon; Jeong, Joon Won; Go, Se Eun; You, Chan Ran; Jeon, Eun Jung; Choi, Sang Wook
2014-02-21
To evaluate the applicability of AIMS65 scores in predicting outcomes of peptic ulcer bleeding. This was a retrospective study in a single center between January 2006 and December 2011. We enrolled 522 patients with upper gastrointestinal haemorrhage who visited the emergency room. High-risk patients were regarded as those who had re-bleeding within 30 d from the first endoscopy as well as those who died within 30 d of visiting the Emergency room. A total of 149 patients with peptic ulcer bleeding were analysed, and the AIMS65 score was used to retrospectively predict the high-risk patients. A total of 149 patients with peptic ulcer bleeding were analysed. The poor outcome group comprised 28 patients [male: 23 (82.1%) vs female: 5 (10.7%)] while the good outcome group included 121 patients [male: 93 (76.9%) vs female: 28 (23.1%)]. The mean age in each group was not significantly different. The mean serum albumin levels in the poor outcome group were slightly lower than those in the good outcome group (P = 0.072). For the prediction of poor outcome, the AIMS65 score had a sensitivity of 35.5% (95%CI: 27.0-44.8) and a specificity of 82.1% (95%CI: 63.1-93.9) at a score of 0. The AIMS65 score was insufficient for predicting outcomes in peptic ulcer bleeding (area under curve = 0.571; 95%CI: 0.49-0.65). The AIMS65 score may therefore not be suitable for predicting clinical outcomes in peptic ulcer bleeding. Low albumin levels may be a risk factor associated with high mortality in peptic ulcer bleeding.
Directory of Open Access Journals (Sweden)
Rishi Anil Aggarwal
2016-01-01
Full Text Available Context: Preoperative severity of myelopathy, age, and duration of symptoms have been shown to be highly predictive of the outcome in compressive cervical myelopathy (CCM. The role of radiological parameters is still controversial. Aims: Define the prognostic factors in CCM and formulate a prognostic score to predict the outcome following surgery in CCM. Settings and Design: Retrospective. Materials and Methods: This study included 78 consecutive patients with CCM treated surgically. The modified Japanese Orthopaedic Association (mJOA scale was used to quantify severity of myelopathy at admission and at 12-month follow-up. The outcome was defined as "good" if the patient had mJOA score ≥16 and "poor" if the score was <16. Age, sex, duration of symptoms, comorbidities, intrinsic hand muscle wasting (IHMW, diagnosis, surgical technique, Torg ratio, instability on dynamic radiographs, and magnetic resonance imaging (MRI signal intensity changes were assessed. Statistics: Statistical Package for the Social Sciences (SPSS (version 20.0 was used for statistical analysis. The association was assessed amongst variables using logistic regression analysis. Parameters having a statistically significant correlation with the outcome were included in formulating a prognostic score. Results: Severity of myelopathy, IHMW, age, duration, diabetes, and instability on radiographs were predictive of the outcome with a P value <0.01. Genders, diagnosis, surgical procedure, Torg ratio, and intensity changes on MRI were not significantly related to the outcome. A 8-point scoring system was devised incorporating the significant clinicoradiological parameters, and it was found that nearly all patients (97.82% with a score below 5 had good outcome and all patients (100% with a score above 5 had poor outcome. The outcome is difficult to predict with a score of 5. Conclusions: Clinical parameters are better predictors of the outcome as compared to radiological findings
Del Arco, Alberto; Park, Junchol; Wood, Jesse; Kim, Yunbok; Moghaddam, Bita
2017-08-30
The prefrontal cortex (PFC) is thought to play a critical role in behavioral flexibility by monitoring action-outcome contingencies. How PFC ensembles represent shifts in behavior in response to changes in these contingencies remains unclear. We recorded single-unit activity and local field potentials in the dorsomedial PFC (dmPFC) of male rats during a set-shifting task that required them to update their behavior, among competing options, in response to changes in action-outcome contingencies. As behavior was updated, a subset of PFC ensembles encoded the current trial outcome before the outcome was presented. This novel outcome-prediction encoding was absent in a control task, in which actions were rewarded pseudorandomly, indicating that PFC neurons are not merely providing an expectancy signal. In both control and set-shifting tasks, dmPFC neurons displayed postoutcome discrimination activity, indicating that these neurons also monitor whether a behavior is successful in generating rewards. Gamma-power oscillatory activity increased before the outcome in both tasks but did not differentiate between expected outcomes, suggesting that this measure is not related to set-shifting behavior but reflects expectation of an outcome after action execution. These results demonstrate that PFC neurons support flexible rule-based action selection by predicting outcomes that follow a particular action. SIGNIFICANCE STATEMENT Tracking action-outcome contingencies and modifying behavior when those contingencies change is critical to behavioral flexibility. We find that ensembles of dorsomedial prefrontal cortex neurons differentiate between expected outcomes when action-outcome contingencies change. This predictive mode of signaling may be used to promote a new response strategy at the service of behavioral flexibility. Copyright © 2017 the authors 0270-6474/17/378363-11$15.00/0.
International Nuclear Information System (INIS)
Sommer, C. M.; Lemm, G.; Hohenstein, E.; Bellemann, N.; Stampfl, U.; Goezen, A. S.; Rassweiler, J.; Kauczor, H. U.; Radeleff, B. A.; Pereira, P. L.
2013-01-01
Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m 2 before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m 2 after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.
Predicting radiotherapy outcomes using statistical learning techniques
International Nuclear Information System (INIS)
El Naqa, Issam; Bradley, Jeffrey D; Deasy, Joseph O; Lindsay, Patricia E; Hope, Andrew J
2009-01-01
Radiotherapy outcomes are determined by complex interactions between treatment, anatomical and patient-related variables. A common obstacle to building maximally predictive outcome models for clinical practice is the failure to capture potential complexity of heterogeneous variable interactions and applicability beyond institutional data. We describe a statistical learning methodology that can automatically screen for nonlinear relations among prognostic variables and generalize to unseen data before. In this work, several types of linear and nonlinear kernels to generate interaction terms and approximate the treatment-response function are evaluated. Examples of institutional datasets of esophagitis, pneumonitis and xerostomia endpoints were used. Furthermore, an independent RTOG dataset was used for 'generalizabilty' validation. We formulated the discrimination between risk groups as a supervised learning problem. The distribution of patient groups was initially analyzed using principle components analysis (PCA) to uncover potential nonlinear behavior. The performance of the different methods was evaluated using bivariate correlations and actuarial analysis. Over-fitting was controlled via cross-validation resampling. Our results suggest that a modified support vector machine (SVM) kernel method provided superior performance on leave-one-out testing compared to logistic regression and neural networks in cases where the data exhibited nonlinear behavior on PCA. For instance, in prediction of esophagitis and pneumonitis endpoints, which exhibited nonlinear behavior on PCA, the method provided 21% and 60% improvements, respectively. Furthermore, evaluation on the independent pneumonitis RTOG dataset demonstrated good generalizabilty beyond institutional data in contrast with other models. This indicates that the prediction of treatment response can be improved by utilizing nonlinear kernel methods for discovering important nonlinear interactions among model
Fetal omphalocele ratios predict outcomes in prenatally diagnosed omphalocele.
Montero, Freddy J; Simpson, Lynn L; Brady, Paula C; Miller, Russell S
2011-09-01
The objective of the study was to evaluate whether ratios considering omphalocele diameter relative to fetal biometric measurements perform better than giant omphalocele designation at predicting inability to achieve neonatal primary surgical closure. Cases of fetal omphalocele that underwent evaluation between May 2003 and July 2010 were identified. Inclusion was restricted to live births with plan for postnatal repair. Omphalocele diameter upon antenatal ultrasound was compared with abdominal circumference, femur length, and head circumference, yielding the respective omphalocele (O)/abdominal circumference (AC), O/femur length (FL), and O/head circumference (HC) ratios. The absolute measurements were used to classify giant lesions. Omphalocele ratios and giant omphalocele designations were evaluated as predictors of inability to achieve primary repair. Among 25 included cases, staged or delayed closure occurred in 52%. With an optimal cutoff of 0.21 or greater, O/HC best predicted the primary outcome (sensitivity, 84.6%; specificity, 58.3%; odds ratio, 7.7). The O/HC of 0.21 or greater outperformed giant designations. The O/HC of 0.21 or greater best predicted staged or delayed omphalocele closure. Giant omphalocele designation, regardless of definition, poorly predicted outcome. Copyright © 2011 Mosby, Inc. All rights reserved.
Jones, David G; Haldar, Shouvik K; Jarman, Julian W E; Johar, Sofian; Hussain, Wajid; Markides, Vias; Wong, Tom
2013-08-01
Ablation of persistent atrial fibrillation can be challenging, often involving not only pulmonary vein isolation (PVI) but also additional linear lesions and ablation of complex fractionated electrograms (CFE). We examined the impact of stepwise ablation on a human model of advanced atrial substrate of persistent atrial fibrillation in heart failure. In 30 patients with persistent atrial fibrillation and left ventricular ejection fraction ≤35%, high-density CFE maps were recorded biatrially at baseline, in the left atrium (LA) after PVI and linear lesions (roof and mitral isthmus), and biatrially after LA CFE ablation. Surface area of CFE (mean cycle length ≤120 ms) remote to PVI and linear lesions, defined as CFE area, was reduced after PVI (18.3±12.03 to 10.2±7.1 cm(2); Patrial CFE area was reduced by LA ablation, from 25.9±14.1 to 12.9±11.8 cm(2) (Patrial CFE area. Reduction of CFE area at sites remote from ablation would suggest either regression of the advanced atrial substrate or that these CFE were functional phenomena. Nevertheless, in an advanced atrial fibrillation substrate, linear lesions after PVI diminished the target area for CFE ablation, and complete lesions resulted in a favorable clinical outcome.
Directory of Open Access Journals (Sweden)
Fabián Pitoia
2012-01-01
Full Text Available To supplement limited relevant literature, we retrospectively compared ablation and disease outcomes in high-risk differentiated thyroid carcinoma (DTC patients undergoing radioiodine thyroid remnant ablation aided by recombinant human thyrotropin (rhTSH versus thyroid hormone withdrawal/withholding (THW. Our cohort was 45 consecutive antithyroglobulin antibody- (TgAb- negative, T3-T4/N0-N1-Nx/M0 adults ablated with high activities at three referral centers. Ablation success comprised negative (<1 μg/L stimulated serum thyroglobulin (Tg and TgAb, with absent or <0.1% scintigraphic thyroid bed uptake. “No evidence of disease” (NED comprised negative unstimulated/stimulated Tg and no suspicious neck ultrasonography or pathological imaging or biopsy. “Persistent disease” was failure to achieve NED, “recurrence,” loss of NED status. rhTSH patients (n=18 were oftener ≥45 years old and higher stage (P=0.01, but otherwise not different than THW patients (n=27 at baseline. rhTSH patients were significantly oftener successfully ablated compared to THW patients (83% versus 67%, P<0.02. After respective 3.3 yr and 4.5 yr mean follow-ups (P=0.02, NED was achieved oftener (72% versus 59% and persistent disease was less frequent in rhTSH patients (22% versus 33% (both comparisons P=0.03. rhTSH stimulation is associated with at least as good outcomes as is THW in ablation of high-risk DTC patients.
Pitoia, Fabián; Marlowe, Robert J; Abelleira, Erika; Faure, Eduardo N; Bueno, Fernanda; Schwarzstein, Diego; Lutfi, Rubén Julio; Niepomniszcze, Hugo
2012-01-01
To supplement limited relevant literature, we retrospectively compared ablation and disease outcomes in high-risk differentiated thyroid carcinoma (DTC) patients undergoing radioiodine thyroid remnant ablation aided by recombinant human thyrotropin (rhTSH) versus thyroid hormone withdrawal/withholding (THW). Our cohort was 45 consecutive antithyroglobulin antibody- (TgAb-) negative, T3-T4/N0-N1-Nx/M0 adults ablated with high activities at three referral centers. Ablation success comprised negative (<1 μg/L) stimulated serum thyroglobulin (Tg) and TgAb, with absent or <0.1% scintigraphic thyroid bed uptake. "No evidence of disease" (NED) comprised negative unstimulated/stimulated Tg and no suspicious neck ultrasonography or pathological imaging or biopsy. "Persistent disease" was failure to achieve NED, "recurrence," loss of NED status. rhTSH patients (n = 18) were oftener ≥45 years old and higher stage (P = 0.01), but otherwise not different than THW patients (n = 27) at baseline. rhTSH patients were significantly oftener successfully ablated compared to THW patients (83% versus 67%, P < 0.02). After respective 3.3 yr and 4.5 yr mean follow-ups (P = 0.02), NED was achieved oftener (72% versus 59%) and persistent disease was less frequent in rhTSH patients (22% versus 33%) (both comparisons P = 0.03). rhTSH stimulation is associated with at least as good outcomes as is THW in ablation of high-risk DTC patients.
Influence of ablation wavelength and time on optical properties of laser ablated carbon dots
Isnaeni, Hanna, M. Yusrul; Pambudi, A. A.; Murdaka, F. H.
2017-01-01
Carbon dots, which are unique and applicable materials, have been produced using many techniques. In this work, we have fabricated carbon dots made of coconut fiber using laser ablation technique. The purpose of this work is to evaluate two ablation parameters, which are ablation wavelength and ablation time. We used pulsed laser from Nd:YAG laser with emit wavelength at 355 nm, 532 nm and 1064 nm. We varied ablation time one hour and two hours. Photoluminescence and time-resolved photoluminescence setup were used to study the optical properties of fabricated carbon dots. In general, fabricated carbon dots emit bluish green color emission upon excitation by blue laser. We found that carbon dots fabricated using 1064 nm laser produced the highest carbon dots emission among other samples. The peak wavelength of carbon dots emission is between 495 nm until 505 nm, which gives bluish green color emission. Two hours fabricated carbon dots gave four times higher emission than one hour fabricated carbon dot. More emission intensity of carbon dots means more carbon dots nanoparticles were fabricated during laser ablation process. In addition, we also measured electron dynamics of carbon dots using time-resolved photoluminescence. We found that sample with higher emission has longer electron decay time. Our finding gives optimum condition of carbon dots fabrication from coconut fiber using laser ablation technique. Moreover, fabricated carbon dots are non-toxic nanoparticles that can be applied for health, bio-tagging and medical applications.
Du, Juan; Yang, Fang; Zhang, Zhiqiang; Hu, Jingze; Xu, Qiang; Hu, Jianping; Zeng, Fanyong; Lu, Guangming; Liu, Xinfeng
2018-05-15
An accurate prediction of long term outcome after stroke is urgently required to provide early individualized neurorehabilitation. This study aimed to examine the added value of early neuroimaging measures and identify the best approaches for predicting motor outcome after stroke. This prospective study involved 34 first-ever ischemic stroke patients (time since stroke: 1-14 days) with upper limb impairment. All patients underwent baseline multimodal assessments that included clinical (age, motor impairment), neurophysiological (motor-evoked potentials, MEP) and neuroimaging (diffusion tensor imaging and motor task-based fMRI) measures, and also underwent reassessment 3 months after stroke. Bivariate analysis and multivariate linear regression models were used to predict the motor scores (Fugl-Meyer assessment, FMA) at 3 months post-stroke. With bivariate analysis, better motor outcome significantly correlated with (1) less initial motor impairment and disability, (2) less corticospinal tract injury, (3) the initial presence of MEPs, (4) stronger baseline motor fMRI activations. In multivariate analysis, incorporating neuroimaging data improved the predictive accuracy relative to only clinical and neurophysiological assessments. Baseline fMRI activation in SMA was an independent predictor of motor outcome after stroke. A multimodal model incorporating fMRI and clinical measures best predicted the motor outcome following stroke. fMRI measures obtained early after stroke provided independent prediction of long-term motor outcome.
International Nuclear Information System (INIS)
Schramm, W.
2010-01-01
volume by using whole-body hyperthermia to heat the patient. This study was done using FEA by comparing the outcome of different models with an initial defined body temperature of 36.7 o C, 37.0 o C, 37.5 o C and 40 o C respectively. The study shows that there is little difference in coagulation zone dimensions with body temperatures in the normal range (36.7 o C to 37.5 o C) but show a significant increase (5.4 mm in the short axis, 3.4 mm in the long axis) in initial body temperatures of 40.0 o C. Since one of the most prevalent shortcomings of FEA simulations of ablations is low accuracy when estimating the effect of microvascular perfusion during ablations, another FEA project was set-up to improve this situation. A algorithm using a first-order kinetic Arrhenius model based on current experimental research was developed to increase simulation accuracy. The results gained from this study show a temperature profile, which is closer to in-vivo ablation results when compared with previous studies. Based on the ablation observations and interviews with physicians requirements for a platform for supporting physicians during ablations where collected. Requirements were split into non-functional, data acquisition, image processing, visualization and treatment simulation requirements. These requirements were the foundation for a prototype implemented using the Slicer Framework which provides the necessary functionality for providing additional information for ablation planning. User feedback showed, that an accurate coagulation zone simulation is often not feasible during an intervention because of the narrow time-window of such a procedure. A simplified simulation approach were the resulting coagulation zone is approximated using values provided by the vendor was developed. This presents a time saving alternative which received good feedback from clinicians. The proposed method is also well suited for post-treatment coagulation zone evaluation if used with image
International Nuclear Information System (INIS)
Baladi, Arash; Sarraf Mamoory, Rasoul
2010-01-01
Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol, acetone, and ethylene glycol. Transmission Electron Microscope (TEM) and Scanning Electron Microscope (SEM) images, Particle size distribution diagram from Laser Particle Size Analyzer (LPSA), UV-visible absorption spectra, and weight changes of targets were used for the characterization and comparison of products. The experiments demonstrated that ablation efficiency in ethylene glycol is too low, in ethanol is higher, and in acetone is highest. Comparison between ethanol and acetone clarified that acetone medium leads to finer nanoparticles (mean diameter of 30 nm) with narrower size distribution (from 10 to 100 nm). However, thin carbon layer coats some of them, which was not observed in ethanol medium. It was also revealed that higher ablation time resulted in higher ablated mass, but lower ablation rate. Finer nanoparticles, moreover, were synthesized in higher ablation times.
Energy Technology Data Exchange (ETDEWEB)
Baladi, Arash [Materials Engineering Department, Tarbiat Modares University, Jalal Al Ahmad, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Sarraf Mamoory, Rasoul, E-mail: rsarrafm@modares.ac.ir [Materials Engineering Department, Tarbiat Modares University, Jalal Al Ahmad, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of)
2010-10-01
Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol, acetone, and ethylene glycol. Transmission Electron Microscope (TEM) and Scanning Electron Microscope (SEM) images, Particle size distribution diagram from Laser Particle Size Analyzer (LPSA), UV-visible absorption spectra, and weight changes of targets were used for the characterization and comparison of products. The experiments demonstrated that ablation efficiency in ethylene glycol is too low, in ethanol is higher, and in acetone is highest. Comparison between ethanol and acetone clarified that acetone medium leads to finer nanoparticles (mean diameter of 30 nm) with narrower size distribution (from 10 to 100 nm). However, thin carbon layer coats some of them, which was not observed in ethanol medium. It was also revealed that higher ablation time resulted in higher ablated mass, but lower ablation rate. Finer nanoparticles, moreover, were synthesized in higher ablation times.
Energy Technology Data Exchange (ETDEWEB)
McEachen, James C., E-mail: james.mceachen2@gmail.com [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Leng, Shuai; Atwell, Thomas D. [Mayo Clinic, Department of Radiology (United States); Tollefson, Matthew K. [Mayo Clinic, Department of Urology (United States); Friese, Jeremy L. [Mayo Clinic, Department of Radiology (United States); Wang, Zhen; Murad, M. Hassan [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Schmit, Grant D. [Mayo Clinic, Department of Radiology (United States)
2016-02-15
IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.
Enhancement After Myopic Small Incision Lenticule Extraction (SMILE) Using Surface Ablation.
Siedlecki, Jakob; Luft, Nikolaus; Kook, Daniel; Wertheimer, Christian; Mayer, Wolfgang J; Bechmann, Martin; Wiltfang, Rainer; Priglinger, Siegfried G; Sekundo, Walter; Dirisamer, Martin
2017-08-01
To report the feasibility and outcomes of surface ablation after small incision lenticule extraction (SMILE). In this retrospective evaluation of 1,963 SMILE procedures, 43 eyes (2.2%) were re-treated at three separate clinics. Of these, 40 eyes of 28 patients with a follow-up of at least 3 months were included in the analysis. During surface ablation, mitomycin C was applied for haze prevention. Spherical equivalent was -6.35 ± 1.31 diopters (D) before SMILE and -0.86 ± 0.43 D before surface ablation. Surface ablation was performed after a mean of 9.82 ± 5.27 months and resulted in a spherical equivalent of 0.03 ± 0.57 D at 3 months (P line. Corrected distance visual acuity (CDVA) remained unchanged with 0.01 ± 0.07 logMAR before versus -0.01 ± 0.05 logMAR after re-treatment (P = .99). Six eyes (15.0%) lost one line of CDVA, but final CDVA was 0.00 logMAR in four and 0.10 logMAR in two of these cases. The safety and efficacy indices were 1.06 and 0.90 at 3 months, respectively. Three of the four surface ablation profiles (Triple-A, tissue-saving algorithm, and topography-guided) resulted in equally good results, whereas enhancement with the aspherically optimized profile (ASA), used in two eyes, resulted in overcorrection (+1.38 and +1.75 D). Combined with the intraoperative application of mitomycin C, surface ablation seems to be a safe and effective method of secondary enhancement after SMILE. Due to the usually low residual myopia, the ASA profile is not recommended in these cases. [J Refract Surg. 2017;33(8):513-518.]. Copyright 2017, SLACK Incorporated.
Predicting Community College Outcomes: Does High School CTE Participation Have a Significant Effect?
Dietrich, Cecile; Lichtenberger, Eric; Kamalludeen, Rosemaliza
2016-01-01
This study explored the relative importance of participation in high school career and technical education (CTE) programs in predicting community college outcomes. A hierarchical generalized linear model (HGLM) was used to predict community college outcome attainment among a random sample of direct community college entrants. Results show that…
Ai, Haiming; Wu, Shuicai; Gao, Hongjian; Zhao, Lei; Yang, Chunlan; Zeng, Yi
2012-01-01
The temperature distribution in the region near a microwave antenna is a critical factor that affects the entire temperature field during microwave ablation of tissue. It is challenging to predict this distribution precisely, because the temperature in the near-antenna region varies greatly. The effects of water vaporisation and subsequent tissue carbonisation in an ex vivo porcine liver were therefore studied experimentally and in simulations. The enthalpy and high-temperature specific absorption rate (SAR) of liver tissues were calculated and incorporated into the simulation process. The accuracy of predictions for near-field temperatures in our simulations has reached the level where the average maximum error is less than 5°C. In addition, a modified thermal model that accounts for water vaporisation and the change in the SAR distribution pattern is proposed and validated with experiment. The results from this study may be useful in the clinical practice of microwave ablation and can be applied to predict the temperature field in surgical planning.
Using FT-IR Spectroscopy to Elucidate the Structures of Ablative Polymers
Fan, Wendy
2011-01-01
The composition and structure of an ablative polymer has a multifaceted influence on its thermal, mechanical and ablative properties. Understanding the molecular level information is critical to the optimization of material performance because it helps to establish correlations with the macroscopic properties of the material, the so-called structure-property relationship. Moreover, accurate information of molecular structures is also essential to predict the thermal decomposition pathways as well as to identify decomposition species that are fundamentally important to modeling work. In this presentation, I will describe the use of infrared transmission spectroscopy (FT-IR) as a convenient tool to aid the discovery and development of thermal protection system materials.
Role of ventricular tachycardia ablation in arrhythmogenic right ventricular cardiomyopathy
Directory of Open Access Journals (Sweden)
Alberto Cipriani
2017-11-01
Full Text Available Arrhythmogenic right ventricular cardiomyopathy (ARVC is characterized by progressive fibro-fatty replacement of the myocardium that represents the substrate for recurrent sustained ventricular tachycardia (VT. These arrhythmias characterize the clinical course of a sizeable proportion of patients and have significant implications for their quality of life and long-term prognosis. Antiarrhythmic drugs are often poorly tolerated and usually provide incomplete control of arrhythmia relapses. Catheter ablation is a potentially effective strategy to treat frequent VT episodes and ICD shocks in ARVC patients. The aims of this review are to discuss the electrophysiological and electroanatomic substrates of ventricular tachycardia in patients with ARVC and to analyze the role of catheter ablation in their management with particular reference to selection of patients, technical issues, potential complications and outcomes.
Comparison of statistical and clinical predictions of functional outcome after ischemic stroke.
Directory of Open Access Journals (Sweden)
Douglas D Thompson
Full Text Available To determine whether the predictions of functional outcome after ischemic stroke made at the bedside using a doctor's clinical experience were more or less accurate than the predictions made by clinical prediction models (CPMs.A prospective cohort study of nine hundred and thirty one ischemic stroke patients recruited consecutively at the outpatient, inpatient and emergency departments of the Western General Hospital, Edinburgh between 2002 and 2005. Doctors made informal predictions of six month functional outcome on the Oxford Handicap Scale (OHS. Patients were followed up at six months with a validated postal questionnaire. For each patient we calculated the absolute predicted risk of death or dependence (OHS≥3 using five previously described CPMs. The specificity of a doctor's informal predictions of OHS≥3 at six months was good 0.96 (95% CI: 0.94 to 0.97 and similar to CPMs (range 0.94 to 0.96; however the sensitivity of both informal clinical predictions 0.44 (95% CI: 0.39 to 0.49 and clinical prediction models (range 0.38 to 0.45 was poor. The prediction of the level of disability after stroke was similar for informal clinical predictions (ordinal c-statistic 0.74 with 95% CI 0.72 to 0.76 and CPMs (range 0.69 to 0.75. No patient or clinician characteristic affected the accuracy of informal predictions, though predictions were more accurate in outpatients.CPMs are at least as good as informal clinical predictions in discriminating between good and bad functional outcome after ischemic stroke. The place of these models in clinical practice has yet to be determined.
Predicting The Outcome of Marketing Negotiations: Role-Playing versus Unaided Opinions
JS Armstrong; Philip D. Hutcherson
2005-01-01
Role -playing and unaided opinions were used to forecast the outcome of three negotiations. Consistent with prior re search, role-playing yielded more accurate predictions. In two studies on marketing negotiations, the predictions based on role-playing were correct for 53% of the predictions while unaided opinions were correct for only 7% (p
Hydrodynamic instabilities in an ablation front
International Nuclear Information System (INIS)
Piriz, A R; Portugues, R F
2004-01-01
The hydrodynamic stability of an ablation front is studied for situations in which the wavelength of the perturbations is larger than the distance to the critical surface where the driving radiation is absorbed. An analytical model is presented, and it shows that under conditions in which the thermal flux is limited within the supercritical region of the ablative corona, the front may behave like a flame or like an ablation front, depending on the perturbation wavelength. For relatively long wavelengths the critical and ablation surfaces practically lump together into a unique surface and the front behaves like a flame, whereas for the shortest wavelengths the ablation front substructure is resolved
Hydrodynamic instabilities in an ablation front
Energy Technology Data Exchange (ETDEWEB)
Piriz, A R; Portugues, R F [E.T.S.I. Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain)
2004-06-01
The hydrodynamic stability of an ablation front is studied for situations in which the wavelength of the perturbations is larger than the distance to the critical surface where the driving radiation is absorbed. An analytical model is presented, and it shows that under conditions in which the thermal flux is limited within the supercritical region of the ablative corona, the front may behave like a flame or like an ablation front, depending on the perturbation wavelength. For relatively long wavelengths the critical and ablation surfaces practically lump together into a unique surface and the front behaves like a flame, whereas for the shortest wavelengths the ablation front substructure is resolved.
Understanding reproducibility of human IVF traits to predict next IVF cycle outcome.
Wu, Bin; Shi, Juanzi; Zhao, Wanqiu; Lu, Suzhen; Silva, Marta; Gelety, Timothy J
2014-10-01
Evaluating the failed IVF cycle often provides useful prognostic information. Before undergoing another attempt, patients experiencing an unsuccessful IVF cycle frequently request information about the probability of future success. Here, we introduced the concept of reproducibility and formulae to predict the next IVF cycle outcome. The experimental design was based on the retrospective review of IVF cycle data from 2006 to 2013 in two different IVF centers and statistical analysis. The reproducibility coefficients (r) of IVF traits including number of oocytes retrieved, oocyte maturity, fertilization, embryo quality and pregnancy were estimated using the interclass correlation coefficient between the repeated IVF cycle measurements for the same patient by variance component analysis. The formulae were designed to predict next IVF cycle outcome. The number of oocytes retrieved from patients and their fertilization rate had the highest reproducibility coefficients (r = 0.81 ~ 0.84), which indicated a very close correlation between the first retrieval cycle and subsequent IVF cycles. Oocyte maturity and number of top quality embryos had middle level reproducibility (r = 0.38 ~ 0.76) and pregnancy rate had a relative lower reproducibility (r = 0.23 ~ 0.27). Based on these parameters, the next outcome for these IVF traits might be accurately predicted by the designed formulae. The introduction of the concept of reproducibility to our human IVF program allows us to predict future IVF cycle outcomes. The traits of oocyte numbers retrieved, oocyte maturity, fertilization, and top quality embryos had higher or middle reproducibility, which provides a basis for accurate prediction of future IVF outcomes. Based on this prediction, physicians may counsel their patients or change patient's stimulation plans, and laboratory embryologists may improve their IVF techniques accordingly.
Rosati, Fabrizio; Muneretto, Claudio; Merati, Elisa; Polvani, Gianluca; Moltrasio, Massimo; Tondo, Claudio; Curnis, Antonio; Cerini, Manuel; Metras, Alexandre; Bisleri, Gianluigi
Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm. Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation. Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve
Wright, Matthew; Harks, Erik; Deladi, Szabolcs; Fokkenrood, Steven; Zuo, Fei; Van Dusschoten, Anneke; Kolen, Alexander F; Belt, Harm; Sacher, Frederic; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre
2013-12-01
Steam pops are a risk of irrigated RF ablation even when limiting power delivery. There is currently no way to predict gas formation during ablation. It would be useful to visualize intramyocardial gas formation prior to a steam pop occurring using near-field ultrasound integrated into a RF ablation catheter. In an in vivo open-chest ovine model (n = 9), 86 lesions were delivered to the epicardial surface of the ventricles. Energy was delivered for 15-60 seconds, to achieve lesions with and without steam pops, based on modeling data. The ultrasound image was compared to a digital audio recording from within the pericardium by a blinded observer. Of 86 lesions, 28 resulted in an audible steam pop. For lesions that resulted in a steam pop compared to those that did not (n = 58), the mean power delivered was 8.0 ± 1.8 W versus 6.7 ± 2.0 W, P = 0.006. A change in US contrast due to gas formation in the tissue occurred in all lesions that resulted in a steam pop. In 4 ablations, a similar change in US contrast was observed in the tissue and RF delivery was stopped; in these cases, no pop occurred. The mean depth of gas formation was 0.9 ± 0.8 mm, which correlated with maximal temperature predicted by modeling. Changes in US contrast occurred 7.6 ± 7.2 seconds before the impedance rise and 7.9 ± 6.2 seconds (0.1-17.0) before an audible pop. Integrated US in an RF ablation catheter is able to visualize gas formation intramyocardially several seconds prior to a steam pop occurring. This technology may help prevent complications arising from steam pops. © 2013 Wiley Periodicals, Inc.
Energy Technology Data Exchange (ETDEWEB)
Lagerwaard, Frank J., E-mail: fj.lagerwaard@vumc.nl [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Verstegen, Naomi E.; Haasbeek, Cornelis J.A.; Slotman, Ben J. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Paul, Marinus A. [Department of Thoracic Surgery, VU University Medical Center, Amsterdam (Netherlands); Smit, Egbert F. [Department of Pulmonary Medicine, VU University Medical Center, Amsterdam (Netherlands); Senan, Suresh [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)
2012-05-01
Background: Approximately two-thirds of patients with early-stage non-small-cell lung cancer (NSCLC) in The Netherlands currently undergo surgical resection. As an increasing number of fit patients have elected to undergo stereotactic ablative radiotherapy (SABR) in recent years, we studied outcomes after SABR in patients with potentially operable stage I NSCLC. Methods and Materials: In an institutional prospective database collected since 2003, 25% of lung SABR cases (n = 177 patients) were found to be potentially operable when the following patients were excluded: those with (1) synchronous lung tumors or other malignancy, (2) prior high-dose radiotherapy/pneumonectomy, (3) chronic obstructive pulmonary disease with a severity score of 3-4 according to the Global initiative for Obstructive Lung Disease classification. (4) a performance score of {>=}3, and (5) other comorbidity precluding surgery. Study patients included 101 males and 76 females, with a median age of 76 years old, 60% of whom were staged as T1 and 40% of whom were T2. Median Charlson comorbidity score was 2 (range, 0-5). A SABR dose of 60 Gy was delivered using a risk-adapted scheme in 3, 5, or 8 fractions, depending on tumor size and location. Follow-up chest computed tomography scans were obtained at 3, 6, and 12 months and yearly thereafter. Results: Median follow-up was 31.5 months; and median overall survival (OS) was 61.5 months, with 1- and 3-year survival rates of 94.7% and 84.7%, respectively. OS rates at 3 years in patients with (n = 59) and without (n = 118) histological diagnosis did not differ significantly (96% versus 81%, respectively, p = 0.39). Post-SABR 30-day mortality was 0%, while predicted 30-day mortality for a lobectomy, derived using the Thoracoscore predictive model (Falcoz PE et al. J Thorac Cardiovasc Surg 2007;133:325-332), would have been 2.6%. Local control rates at 1 and 3 years were 98% and 93%, respectively. Regional and distant failure rates at 3 years were each
Black Hole Sign Predicts Poor Outcome in Patients with Intracerebral Hemorrhage.
Li, Qi; Yang, Wen-Song; Chen, Sheng-Li; Lv, Fu-Rong; Lv, Fa-Jin; Hu, Xi; Zhu, Dan; Cao, Du; Wang, Xing-Chen; Li, Rui; Yuan, Liang; Qin, Xin-Yue; Xie, Peng
2018-01-01
In spontaneous intracerebral hemorrhage (ICH), black hole sign has been proposed as a promising imaging marker that predicts hematoma expansion in patients with ICH. The aim of our study was to investigate whether admission CT black hole sign predicts hematoma growth in patients with ICH. From July 2011 till February 2016, patients with spontaneous ICH who underwent baseline CT scan within 6 h of symptoms onset and follow-up CT scan were recruited into the study. The presence of black hole sign on admission non-enhanced CT was independently assessed by 2 readers. The functional outcome was assessed using the modified Rankin Scale (mRS) at 90 days. Univariate and multivariable logistic regression analyses were performed to assess the association between the presence of the black hole sign and functional outcome. A total of 225 patients (67.6% male, mean age 60.3 years) were included in our study. Black hole sign was identified in 32 of 225 (14.2%) patients on admission CT scan. The multivariate logistic regression analysis demonstrated that age, intraventricular hemorrhage, baseline ICH volume, admission Glasgow Coma Scale score, and presence of black hole sign on baseline CT independently predict poor functional outcome at 90 days. There are significantly more patients with a poor functional outcome (defined as mRS ≥4) among patients with black hole sign than those without (84.4 vs. 32.1%, p black hole sign independently predicts poor outcome in patients with ICH. Early identification of black hole sign is useful in prognostic stratification and may serve as a potential therapeutic target for anti-expansion clinical trials. © 2018 S. Karger AG, Basel.
Muser, Daniele; Liang, Jackson J; Pathak, Rajeev K; Magnani, Silvia; Castro, Simon A; Hayashi, Tatsuya; Garcia, Fermin C; Supple, Gregory E; Riley, Michael P; Lin, David; Dixit, Sanjay; Zado, Erica S; Frankel, David S; Callans, David J; Marchlinski, Francis E; Santangeli, Pasquale
2017-07-01
The goal of this study was to determine the long-term outcomes of catheter ablation (CA) of electrical storm in patients with nonischemic dilated cardiomyopathy (NIDCM) compared with patients with ischemic cardiomyopathy (ICM). CA of ventricular tachycardia (VT) electrical storm has been shown to improve VT-free survival in patients with ICM. Data on the outcomes of CA of electrical storm in patients with NIDCM are insufficient. The study included 267 consecutive patients with NIDCM (n = 71; ejection fraction 32 ± 14%) and ICM (n = 196; ejection fraction 28 ± 12%). Endo-epicardial CA was performed in 59 (22%) patients. CA was guided by activation and entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. After a median follow-up of 45 (25th to 75th percentile: 9 to 71) months and 1 (25th to 75th percentile: 1 to 8) procedures, 76 (29%) patients died, 25 (9%) underwent heart transplantation, 87 (33%) experienced VT recurrence, and 13 (5%) had recurrence of electrical storm. Overall VT-free survival was 54% at 60 months (48% in NIDCM and 54% in ICM; p = 0.128). Patients with VT recurrence experienced a median of 2 (1 to 10) VT episodes in the 5 (1 to 14) months after the procedure. Death/transplantation-free survival was 62% at 60 months (53% in NIDCM and 64% in ICM; p = 0.067). Persistent inducibility of any VT with cycle length ≥250 ms at programmed stimulation at the end of the procedure was the only independent predictor of VT recurrence. Low ejection fraction, New York Heart Association functional class, and VT recurrence over follow-up independently predicted death/transplantation. CA of electrical storm was similarly effective in patients with NIDCM compared with patients with ICM, with elimination of electrical storm in 95% of cases and achievement of complete VT control at long-term follow-up in most patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc
Radio frequency ablation of small renal tumors:: intermediate results.
Hwang, J J; Walther, M M; Pautler, S E; Coleman, J A; Hvizda, J; Peterson, James; Linehan, W M; Wood, B J
2004-05-01
With evolving radio frequency technology, the clinical application of radio frequency ablation (RFA) has been actively investigated in the treatment for small renal tumors. We present our intermediate patient outcomes after RFA. Since January 2001, 17 patients with a total of 24 hereditary renal tumors ranging from 1.2 to 2.85 cm were treated with RFA using the 200 W Cool-tip RF System (Radionics, Burlington, Massachusetts) under laparoscopic (9) or percutaneous (8) guidance and had a minimum 1-year followup. A percutaneous approach was considered unsuitable if kidney tumors were contiguous to bowel, ureter or large vessels. Treatment eligibility criteria included an average tumor diameter of less than 3.0 cm, tumor growth during 1 year and solid appearance with contrast enhancement (HU change greater than 20) on computerized tomography (CT). Postoperative followup consisted of CT with and without intravenous contrast, and renal function assessment at regular intervals. Median patient age was 38 years (range 20 to 51). At a median followup of 385 days (range 342 to 691), median tumor or thermal lesion diameter decreased from 2.26 to 1.62 cm (p = 0.0013), and only 1 lesion (4%), which was located centrally near the hilum, exhibited contrast enhancement (HU change greater than 10) on CT at 12 months. Of the 15 renal tumors ablated laparoscopically, 13 were in direct contact with the bowel and 2 were abutting the ureter, necessitating mobilization before RFA. Laparoscopic ultrasound was used to guide radio frequency electrode placement and monitor the ablation process in these cases. Operative time and intraoperative blood loss (mean +/- standard mean of error) were 243 +/- 29 minutes and 67 +/- 9 cc, respectively. In 1 patient whose ureter was adherent to the tumor a ureteropelvic junction obstruction developed after laparoscopic RFA, requiring open repair. At the minimum 1-year followup 23 of 24 ablated tumors lacked contrast uptake on CT, meeting our radiographic
Aminsharifi, Alireza; Irani, Dariush; Pooyesh, Shima; Parvin, Hamid; Dehghani, Sakineh; Yousofi, Khalilolah; Fazel, Ebrahim; Zibaie, Fatemeh
2017-05-01
To construct, train, and apply an artificial neural network (ANN) system for prediction of different outcome variables of percutaneous nephrolithotomy (PCNL). We calculated predictive accuracy, sensitivity, and precision for each outcome variable. During the study period, all adult patients who underwent PCNL at our institute were enrolled in the study. Preoperative and postoperative variables were recorded, and stone-free status was assessed perioperatively with computed tomography scans. MATLAB software was used to design and train the network in a feed forward back-propagation error adjustment scheme. Preoperative and postoperative data from 200 patients (training set) were used to analyze the effect and relative relevance of preoperative values on postoperative parameters. The validated adequately trained ANN was used to predict postoperative outcomes in the subsequent 254 adult patients (test set) whose preoperative values were serially fed into the system. To evaluate system accuracy in predicting each postoperative variable, predicted values were compared with actual outcomes. Two hundred fifty-four patients (155 [61%] males) were considered the test set. Mean stone burden was 6702.86 ± 381.6 mm 3 . Overall stone-free rate was 76.4%. Fifty-four out of 254 patients (21.3%) required ancillary procedures (shockwave lithotripsy 5.9%, transureteral lithotripsy 10.6%, and repeat PCNL 4.7%). The accuracy and sensitivity of the system in predicting different postoperative variables ranged from 81.0% to 98.2%. As a complex nonlinear mathematical model, our ANN system is an interconnected data mining tool, which prospectively analyzes and "learns" the relationships between variables. The accuracy and sensitivity of the system for predicting the stone-free rate, the need for blood transfusion, and post-PCNL ancillary procedures ranged from 81.0% to 98.2%.The stone burden and the stone morphometry were among the most significant preoperative characteristics that
Catheter ablation of epicardial ventricular tachycardia
Directory of Open Access Journals (Sweden)
Takumi Yamada, MD, PhD
2014-08-01
Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their
Song, Changho; Jin, Moo-Nyun; Lee, Jung-Hee; Kim, In-Soo; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung
2014-01-01
Purpose The identification of sick sinus syndrome (SSS) in patients with atrial flutter (AFL) is difficult before the termination of AFL. This study investigated the patient characteristics used in predicting a high risk of SSS after AFL ablation. Materials and Methods Out of 339 consecutive patients who had undergone radiofrequency ablation for AFL from 1991 to 2012, 27 (8%) had SSS (SSS group). We compared the clinical characteristics of patients with and without SSS (n=312, no-SSS group). ...
Aslanides, Ioannis M; Kolli, Sai; Padroni, Sara; Padron, Sara; Arba Mosquera, Samuel
2012-05-01
To evaluate the long-term outcomes of aspheric corneal wavefront ablation profiles for excimer laser retreatment. Eighteen eyes that had previously undergone LASIK or photorefractive keratectomy (PRK) were retreated with LASIK using the corneal wavefront ablation profile. Custom Ablation Manager (SCHWIND eye-tech-solutions, Kleinostheim, Germany) software and the ESIRIS flying spot excimer laser system (SCHWIND) were used to perform the ablations. Refractive outcomes and wavefront data are reported up to 4 years after retreatment. Pre- and postoperative data were compared with Student t tests and (multivariate) correlation tests. P<.05 was considered statistically significant. A bilinear correlation of various postoperative wavefront aberrations versus planned correction and preoperative aberration was performed. Mean manifest refraction spherical equivalent (MRSE) before retreatment was -0.38±1.85 diopters (D) and -0.09±0.22 D at 6 months and -0.10±0.38 D at 4 years postoperatively. The reduction in MRSE was statistically significant at both postoperative time points (P<.005). Postoperative aberrations were statistically lower (spherical aberration P<.05; coma P<.005; root-mean-square higher order aberration P<.0001) at 4 years postoperatively. Distribution of the postoperative uncorrected distance visual acuity (P<.0001) and corrected distance visual acuity (P<.01) were statistically better than preoperative values. Aspheric corneal wavefront customization with the ESIRIS yields visual, optical, and refractive results comparable to those of other wavefront-guided customized techniques for the correction of myopia and myopic astigmatism. The corneal wavefront customized approach shows its strength in cases where abnormal optical systems are expected. Systematic wavefront customized corneal ablation appears safe and efficacious for retreatment cases. Copyright 2012, SLACK Incorporated.
[Radiofrequency ablation of hepatocellular carcinoma].
Widmann, Gerlig; Schullian, Peter; Bale, Reto
2013-03-01
Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.
Predictive efficacy of radioisotope voiding cystography for renal outcome
International Nuclear Information System (INIS)
Kim, Seok Ki; Lee, Dong Soo; Kim, Kwang Myeung; Choi, Whang; Chung, June Key; Lee, Myung Chul
2000-01-01
As vesicoureteral reflux (VUR) could lead to renal functional deterioration when combined with urinary tract infection, we need to decide whether operative anti-reflux treatment should be performed at the time of diagnosis of VUR. Predictive value of radioisotope voiding cystography (RIVCG) for renal outcome was tested. In 35 children (18 males, 17 females), radiologic voiding cystoure-thrography (VCU), RIVCG and DMSA scan were performed. Change in renal function was evaluated using the follow-up DMSA scan, ultrasonography, and clinical information. Discriminant analysis was performed using individual or integrated variables such as reflux amount and extent at each phase of voiding on RIVCG, in addition to age, gender and cortical defect on DMSA scan at the time of diagnosis. Discriminant function was composed and its performance was examined. Reflux extent at the filling phase and reflux amount and extent at postvoiding phase had a significant prognostic value. Total reflux amount was a composite variable to predict prognosis. Discriminant function composed of reflux extent at the filling phase and reflux amount and extent at postvoiding phase showed better positive predictive value and specificity than conventional reflux grading. RIVCG could predict renal outcome by disclosing characteristic reflux pattern during various voiding phases.=20
Predicting an optimal outcome after radical prostatectomy: the trifecta nomogram.
Eastham, James A; Scardino, Peter T; Kattan, Michael W
2008-06-01
The optimal outcome after radical prostatectomy for clinically localized prostate cancer is freedom from biochemical recurrence along with the recovery of continence and erectile function, a so-called trifecta. We evaluated our series of open radical prostatectomy cases to determine the likelihood of this outcome and develop a nomogram predicting the trifecta. We reviewed the records of patients undergoing open radical prostatectomy for clinical stage T1c-T3a prostate cancer at our center during 2000 to 2006. Men were excluded if they received preoperative hormonal therapy, chemotherapy or radiation therapy, if pretreatment prostate specific antigen was more than 50 ng/ml, or if they were impotent or incontinent before radical prostatectomy. A total of 1,577 men were included in the study. Freedom from biochemical recurrence was defined as post-radical prostatectomy prostate specific antigen less than 0.2 ng/ml. Continence was defined as not having to wear any protective pads. Potency was defined as erection adequate for intercourse upon most attempts with or without phosphodiesterase-5 inhibitor. Mean patient age was 58 years and mean pretreatment prostate specific antigen was 6.4 ng/ml. A trifecta outcome (cancer-free status with recovery of continence and potency) was achieved in 62% of patients. In a nomogram developed to predict the likelihood of the trifecta baseline prostate specific antigen was the major predictive factor. Area under the ROC curve for the nomogram was 0.773 and calibration appeared excellent. A trifecta (optimal) outcome can be achieved in most men undergoing radical prostatectomy. The nomogram permits patients to estimate preoperatively their likelihood of an optimal outcome after radical prostatectomy.
Takahashi, Edwin A; Kinsman, Kristin A; Schmit, Grant D; Atwell, Thomas D; Schmitz, John J; Welch, Brian T; Callstrom, Matthew R; Geske, Jennifer R; Kurup, A Nicholas
2018-06-04
To evaluate the safety and oncologic efficacy of percutaneous thermal ablation of intrahepatic cholangiocarcinoma (ICC) and identify risk factors for local tumor progression (LTP). Retrospective review of an institutional tumor ablation registry demonstrated that 20 patients (9 males, 11 females; mean age 62.5 ± 15.8 years) with 50 ICCs (mean size 1.8 ± 1.3 cm) were treated with percutaneous radiofrequency ablation (RFA) or microwave ablation (MWA) between 2006 and 2015. Thirty-eight of the treated ICCs (76%) were metastases that developed after surgical resection of the primary tumor. Patient demographics, procedure technical parameters, and clinical outcomes were reviewed. A Cox proportional hazards model was used to examine the risk of LTP by ablation modality. Survival analyses were performed using the Kaplan-Meier method. Mean imaging follow-up time was 41.5 ± 42.7 months. Forty-four (88%) ICCs were treated with RFA, and 6 (12%) with MWA. Eleven (22%) cases of LTP developed in 5 (25%) patients. The median time to LTP among these 11 tumors was 7.1 months (range, 2.3-22.9 months). Risk of LTP was not significantly different for ICCs treated with MWA compared to RFA (HR 2.72; 95% CI 0.58-12.84; p = 03.21). Median disease-free survival was 8.2 months (1.1-70.4 months), and median overall survival was 23.6 months (7.4-122.5 months). No major complication occurred. Percutaneous thermal ablation is a safe and effective treatment for patients with ICCs and may be particularly valuable in unresectable patients, or those who have already undergone hepatic surgery. Tumor size and ablation modality were not associated with LTP, whereas primary tumors and superficially located tumors were more likely to subsequently recur.
A spectral analysis of ablating meteors
Bloxam, K.; Campbell-Brown, M.
2017-09-01
Meteor ablation features in the spectral lines occurring at 394, 436, 520, and 589 nm were observed using a four-camera spectral system between September and December 2015. In conjunction with this multi-camera system the Canadian Automated Meteor Observatory was used to observe the orbital parameters and fragmentation of these meteors. In total, 95 light curves with complete data in the 520 and 589 nm filters were analyzed; some also had partial or complete data in the 394 nm filter, but no usable data was collected with the 436 nm filter. Of the 95 events, 70 exhibited some degree of differential ablation, and in all except 3 of these 70 events the 589 nm filter started or ended sooner compared with the 520 nm filter, indicating early ablation at the 589 nm wavelength. In the majority of cases the meteor showed evidence of fragmentation regardless of the type of ablation (differential or uniform). A surprising result was the lack of correlation found concerning the KB parameter, linked to meteoroid strength, and differential ablation. In addition, 22 shower-associated meteors were observed; Geminids showed mainly slight differential ablation, while Taurids were more likely to ablate uniformly.
Energy Technology Data Exchange (ETDEWEB)
Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua, E-mail: huangjh@sysucc.org.cn; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi [Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China (China)
2016-04-15
ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.
Network control principles predict neuron function in the Caenorhabditis elegans connectome
Yan, Gang; Vértes, Petra E.; Towlson, Emma K.; Chew, Yee Lian; Walker, Denise S.; Schafer, William R.; Barabási, Albert-László
2017-10-01
Recent studies on the controllability of complex systems offer a powerful mathematical framework to systematically explore the structure-function relationship in biological, social, and technological networks. Despite theoretical advances, we lack direct experimental proof of the validity of these widely used control principles. Here we fill this gap by applying a control framework to the connectome of the nematode Caenorhabditis elegans, allowing us to predict the involvement of each C. elegans neuron in locomotor behaviours. We predict that control of the muscles or motor neurons requires 12 neuronal classes, which include neuronal groups previously implicated in locomotion by laser ablation, as well as one previously uncharacterized neuron, PDB. We validate this prediction experimentally, finding that the ablation of PDB leads to a significant loss of dorsoventral polarity in large body bends. Importantly, control principles also allow us to investigate the involvement of individual neurons within each neuronal class. For example, we predict that, within the class of DD motor neurons, only three (DD04, DD05, or DD06) should affect locomotion when ablated individually. This prediction is also confirmed; single cell ablations of DD04 or DD05 specifically affect posterior body movements, whereas ablations of DD02 or DD03 do not. Our predictions are robust to deletions of weak connections, missing connections, and rewired connections in the current connectome, indicating the potential applicability of this analytical framework to larger and less well-characterized connectomes.
Network control principles predict neuron function in the Caenorhabditis elegans connectome.
Yan, Gang; Vértes, Petra E; Towlson, Emma K; Chew, Yee Lian; Walker, Denise S; Schafer, William R; Barabási, Albert-László
2017-10-26
Recent studies on the controllability of complex systems offer a powerful mathematical framework to systematically explore the structure-function relationship in biological, social, and technological networks. Despite theoretical advances, we lack direct experimental proof of the validity of these widely used control principles. Here we fill this gap by applying a control framework to the connectome of the nematode Caenorhabditis elegans, allowing us to predict the involvement of each C. elegans neuron in locomotor behaviours. We predict that control of the muscles or motor neurons requires 12 neuronal classes, which include neuronal groups previously implicated in locomotion by laser ablation, as well as one previously uncharacterized neuron, PDB. We validate this prediction experimentally, finding that the ablation of PDB leads to a significant loss of dorsoventral polarity in large body bends. Importantly, control principles also allow us to investigate the involvement of individual neurons within each neuronal class. For example, we predict that, within the class of DD motor neurons, only three (DD04, DD05, or DD06) should affect locomotion when ablated individually. This prediction is also confirmed; single cell ablations of DD04 or DD05 specifically affect posterior body movements, whereas ablations of DD02 or DD03 do not. Our predictions are robust to deletions of weak connections, missing connections, and rewired connections in the current connectome, indicating the potential applicability of this analytical framework to larger and less well-characterized connectomes.
Directory of Open Access Journals (Sweden)
Daniela Husser
2017-12-01
Full Text Available Background: PR interval prolongation has recently been shown to associate with advanced left atrial remodeling and atrial fibrillation (AF recurrence after catheter ablation. While different genome-wide association studies (GWAS have implicated 13 loci to associate with the PR interval as an AF endophenotype their subsequent associations with AF remodeling and response to catheter ablation are unknown. Here, we perform a gene-based analysis of GWAS data to test the hypothesis that PR interval candidate genes also associate with left atrial remodeling and arrhythmia recurrence following AF catheter ablation.Methods and Results: Samples from 660 patients with paroxysmal (n = 370 or persistent AF (n = 290 undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using VEGAS (versatile gene-based association study. Among the 13 candidate genes, SLC8A1, MEIS1, ITGA9, SCN5A, and SOX5 associated with the PR interval. Of those, ITGA9 and SOX5 were significantly associated with left atrial low voltage areas and left atrial diameter and subsequently with AF recurrence after radiofrequency catheter ablation.Conclusion: This study suggests contributions of ITGA9 and SOX5 to AF remodeling expressed as PR interval prolongation, low voltage areas and left atrial dilatation and subsequently to response to catheter ablation. Future and larger studies are necessary to replicate and apply these findings with the aim of designing AF pathophysiology-based multi-locus risk scores.
Atrial Fibrillation Ablation Guided by a Novel Nonfluoroscopic Navigation System.
Ballesteros, Gabriel; Ramos, Pablo; Neglia, Renzo; Menéndez, Diego; García-Bolao, Ignacio
2017-09-01
Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures. This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity). The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications. The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Audigier, Chloé; Mansi, Tommaso; Delingette, Hervé; Rapaka, Saikiran; Passerini, Tiziano; Mihalef, Viorel; Jolly, Marie-Pierre; Pop, Raoul; Diana, Michele; Soler, Luc; Kamen, Ali; Comaniciu, Dorin; Ayache, Nicholas
2017-09-01
We aim at developing a framework for the validation of a subject-specific multi-physics model of liver tumor radiofrequency ablation (RFA). The RFA computation becomes subject specific after several levels of personalization: geometrical and biophysical (hemodynamics, heat transfer and an extended cellular necrosis model). We present a comprehensive experimental setup combining multimodal, pre- and postoperative anatomical and functional images, as well as the interventional monitoring of intra-operative signals: the temperature and delivered power. To exploit this dataset, an efficient processing pipeline is introduced, which copes with image noise, variable resolution and anisotropy. The validation study includes twelve ablations from five healthy pig livers: a mean point-to-mesh error between predicted and actual ablation extent of 5.3 ± 3.6 mm is achieved. This enables an end-to-end preclinical validation framework that considers the available dataset.
Percutaneous thermal ablation for stage IA non-small cell lung cancer: long-term follow-up.
Narsule, Chaitan K; Sridhar, Praveen; Nair, Divya; Gupta, Avneesh; Oommen, Roy G; Ebright, Michael I; Litle, Virginia R; Fernando, Hiran C
2017-10-01
Surgical resection is the most effective curative therapy for non-small cell lung cancer (NSCLC). However, many patients are unable to tolerate resection secondary to poor reserve or comorbid disease. Radiofrequency ablation (RFA) and microwave ablation (MWA) are methods of percutaneous thermal ablation that can be used to treat medically inoperable patients with NSCLC. We present long-term outcomes following thermal ablation of stage IA NSCLC from a single center. Patients with stage IA NSCLC and factors precluding resection who underwent RFA or MWA from July 2005 to September 2009 were studied. CT and PET-CT scans were performed at 3 and 6 month intervals, respectively, for first 24 months of follow-up. Factors associated with local progression (LP) and overall survival (OS) were analyzed. Twenty-one patients underwent 21 RFA and 4 MWA for a total of 25 ablations. Fifteen patients had T1a and six patients had T1b tumors. Mean follow-up was 42 months, median survival was 39 months, and OS at three years was 52%. There was no significant difference in median survival between T1a nodules and T1b nodules (36 vs . 39 months, P=0.29) or for RFA and MWA (36 vs . 50 months, P=0.80). Ten patients had LP (47.6%), at a median time of 35 months. There was no significant difference in LP between T1a and T1b tumors (22 vs . 35 months, P=0.94) or RFA and MWA (35 vs . 17 months, P=0.18). Median OS with LP was 32 months compared to 39 months without LP (P=0.68). Three patients underwent repeat ablations. Mean time to LP following repeat ablation was 14.75 months. One patient had two repeat ablations and was disease free at 40-month follow-up. Thermal ablation effectively treated or controlled stage IA NSCLC in medically inoperable patients. Three-year OS exceeded 50%, and LP did not affect OS. Therefore, thermal ablation is a viable option for medically inoperable patients with early stage NSCLC.
CT-guided radiofrequency tumor ablation in children
International Nuclear Information System (INIS)
Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia
2014-01-01
Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)
CT-guided radiofrequency tumor ablation in children
Energy Technology Data Exchange (ETDEWEB)
Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)
2014-11-15
Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)
Observations of multimode perturbation decay at non-accelerating, soft x-ray driven ablation fronts
Energy Technology Data Exchange (ETDEWEB)
Loomis, E. N.; Batha, S. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Braun, D.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 95281 (United States)
2012-12-15
Minimizing the growth of hydrodynamic instabilities is a fundamental design issue facing the achievement of thermonuclear ignition and burn with Inertial Confinement Fusion (ICF). The thin capsules and extreme accelerations found in ICF make it an inherently unstable system primarily to Rayleigh-Taylor (RT) occurring at the ablation front. A potential mechanism by which perturbations at the outer capsule surface can be reduced lies in the already present ablative Richtmyer-Meshkov (RM) effect, which operates during the first shock transit of the ablator. At present, the available Equation of State (EOS) models predict a wide range of behavior for the ablative RM oscillations of multimode isolated defects on plastic (CH) capsules. To resolve these differences, we conducted experiments at the OMEGA Laser Facility [T. R. Boehly et al., Optics Comm. 133 (1997)] that measured the evolution of gaussian-shaped bumps driven by soft x-ray ablation from a halfraum. Shock speeds in the CH target were measured to reach 15 {mu}m/ns for halfraum radiation temperatures of 70 eV lasting for up to 7 ns. The evolution of gaussian-shaped bumps of different widths and heights were measured using on-axis x-ray radiography at up to 37 Multiplication-Sign magnification. Bumps with initial widths of 34 and 44 {mu}m FWHM were found to grow by 3 Multiplication-Sign their initial areal density and then saturate out to 6 ns due to lateral compression of the bump characteristic of the formation of a rippled shock front propagating into the solid target. Narrower 17 {mu}m FWHM bumps, on the other hand, grew by roughly 2 Multiplication-Sign followed immediately by a decrease back to initial values of areal density out to 7 ns, which largely agrees with both LEOS 5310 and SESAME 7592 EOS predictions. The difference in observed behavior suggests that high spatial frequency modes found in narrower bumps are needed to significantly affect the ablation front profile on shorter time scales.
Advances in laser ablation of materials
International Nuclear Information System (INIS)
Singh, R.K.; Lowndes, D.H.; Chrisey, D.B.; Fogarassy, E.; Narayan, J.
1998-01-01
The symposium, Advances in Laser Ablation of Materials, was held at the 1998 MRS Spring Meeting in San Francisco, California. The papers in this symposium illustrate the advances in pulsed laser ablation for a wide variety of applications involving semiconductors, superconductors, metals, ceramics, and polymers. In particular, advances in the deposition of oxides and related materials are featured. Papers dealing with both fundamentals and the applications of laser ablation are presented. Topical areas include: fundamentals of ablation and growth; in situ diagnostics and nanoscale synthesis advances in laser ablation techniques; laser surface processing; pulsed laser deposition of ferroelectric, magnetic, superconducting and optoelectronic thin films; and pulsed laser deposition of carbon-based and polymeric materials. Sixty papers have been processed separately for inclusion on the data base
Wysham, Nicholas G; Abernethy, Amy P; Cox, Christopher E
2014-10-01
Prediction models in critical illness are generally limited to short-term mortality and uncommonly include patient-centered outcomes. Current outcome prediction tools are also insensitive to individual context or evolution in healthcare practice, potentially limiting their value over time. Improved prognostication of patient-centered outcomes in critical illness could enhance decision-making quality in the ICU. Patient-reported outcomes have emerged as precise methodological measures of patient-centered variables and have been successfully employed using diverse platforms and technologies, enhancing the value of research in critical illness survivorship and in direct patient care. The learning health system is an emerging ideal characterized by integration of multiple data sources into a smart and interconnected health information technology infrastructure with the goal of rapidly optimizing patient care. We propose a vision of a smart, interconnected learning health system with integrated electronic patient-reported outcomes to optimize patient-centered care, including critical care outcome prediction. A learning health system infrastructure integrating electronic patient-reported outcomes may aid in the management of critical illness-associated conditions and yield tools to improve prognostication of patient-centered outcomes in critical illness.
Choi, In Young; Kim, Pyo Nyun; Lee, Sung Gu; Won, Hyung Jin; Shin, Yong Moon
2017-10-01
To evaluate the safety and efficacy of radiofrequency (RF) ablation for treatment of focal hepatic lesions adjacent to the gallbladder with electrode relocation and ablation time reduction. Thirty-nine patients who underwent RF ablation for focal hepatic lesions adjacent to the gallbladder (≤ 10 mm) were evaluated retrospectively from January 2011 to December 2014 (30 men and 9 women; age range, 51-85 y; mean age, 65 y). Of 36 patients with hepatocellular carcinoma, 3 had a second treatment for recurrence (mean tumor size, 15 mm ± 6). Patients were divided into 2 subgroups based on lesion distance from the gallbladder: nonabutting (> 5 mm; n = 19) and abutting (≤ 5 mm; n = 20). Electrodes were inserted parallel to the gallbladder through the center of a tumor in the nonabutting group and through the center of the expected ablation zone between a 5-mm safety zone on the liver side and the gallbladder in the abutting group. Ablation time was decreased in proportion to the transverse diameter of the expected ablation zone. Technical success and technical effectiveness rates were 89.7% and 97.4%, respectively, with no significant differences between groups (P = 1.00). Local tumor progression was observed in 3 patients (1 in the nonabutting group and 2 in the abutting group; P = 1.00). There were no major complications. The gallbladder was thickened in 10 patients, with no significant difference between groups (P = .72). Biloma occurred in 1 patient in the nonabutting group. RF ablation with electrode relocation and reduction of ablation time can be a safe and effective treatment for focal hepatic lesions adjacent to the gallbladder. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Role of Subdural Electrocorticography in Prediction of Long-Term Seizure Outcome in Epilepsy Surgery
Asano, Eishi; Juhasz, Csaba; Shah, Aashit; Sood, Sandeep; Chugani, Harry T.
2009-01-01
Since prediction of long-term seizure outcome using preoperative diagnostic modalities remains suboptimal in epilepsy surgery, we evaluated whether interictal spike frequency measures obtained from extraoperative subdural electrocorticography (ECoG) recording could predict long-term seizure outcome. This study included 61 young patients (age…
DEFF Research Database (Denmark)
Jin, Qi; Pehrson, Steen; Jacobsen, Peter Karl
2015-01-01
with RMN. METHODS: A total of 313 patients (275 male, age 59 ± 9.5 years) with PsAF (187/313) or L-PsAF (126/313) undergoing ablation using RMN were included. Patients' disease history, pulmonary venous anatomy, left atrial (LA) volume, procedure time, mapping plus ablation time, radiofrequency (RF...
Hernández-Socorro, Carmen Rosa; Saavedra, Pedro; Ramírez Felipe, José; Bohn Sarmiento, Uriel; Ruiz-Santana, Sergio
2017-04-21
The risk factors associated to long-term survival were assessed in patients with liver metastases of colorectal carcinoma undergoing ablative therapies. Single-centre cohort study, retrospectively analysed and prospectively collected consecutive patients with unresectable metastatic liver disease of colorectal carcinoma treated with ablative therapies between 1996 and 2013. Factors associated with survival time were identified using Cox's proportional hazard model with time-dependent covariates. A forward variable selection based on Akaike information criterion was performed. Relative risk and 95% confidence intervals for each factor were calculated. Statistical significance was set as P<.05. Seventy-five patients with liver metastases of colorectal cancer, with a mean age of 65.6 (10.3) underwent 106 treatments. Variables selected were good quality of life (RR 0.308, 95% CI 0.150-0.632) and tumour extension (RR 3.070, 95% CI 1.776-5.308). The median overall survival was 18.5 months (95% CI 17.4-24.4). The survival prognosis in median was 13.5 vs. 23.4 months for patients with and without tumour extension, and 23.0 vs. 12.8 months for patients with good and fair or poor quality of life, respectively. Good quality of life and tumour extension were the only statistically significant predictors of long-term survival in patients of colorectal carcinoma with liver metastatic disease undergoing ablative treatment with ultrasound. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Simple spherical ablative-implosion model
International Nuclear Information System (INIS)
Mayer, F.J.; Steele, J.T.; Larsen, J.T.
1980-01-01
A simple model of the ablative implosion of a high-aspect-ratio (shell radius to shell thickness ratio) spherical shell is described. The model is similar in spirit to Rosenbluth's snowplow model. The scaling of the implosion time was determined in terms of the ablation pressure and the shell parameters such as diameter, wall thickness, and shell density, and compared these to complete hydrodynamic code calculations. The energy transfer efficiency from ablation pressure to shell implosion kinetic energy was examined and found to be very efficient. It may be possible to attach a simple heat-transport calculation to our implosion model to describe the laser-driven ablation-implosion process. The model may be useful for determining other energy driven (e.g., ion beam) implosion scaling
Prediction of cognitive outcome based on the progression of auditory discrimination during coma.
Juan, Elsa; De Lucia, Marzia; Tzovara, Athina; Beaud, Valérie; Oddo, Mauro; Clarke, Stephanie; Rossetti, Andrea O
2016-09-01
To date, no clinical test is able to predict cognitive and functional outcome of cardiac arrest survivors. Improvement of auditory discrimination in acute coma indicates survival with high specificity. Whether the degree of this improvement is indicative of recovery remains unknown. Here we investigated if progression of auditory discrimination can predict cognitive and functional outcome. We prospectively recorded electroencephalography responses to auditory stimuli of post-anoxic comatose patients on the first and second day after admission. For each recording, auditory discrimination was quantified and its evolution over the two recordings was used to classify survivors as "predicted" when it increased vs. "other" if not. Cognitive functions were tested on awakening and functional outcome was assessed at 3 months using the Cerebral Performance Categories (CPC) scale. Thirty-two patients were included, 14 "predicted survivors" and 18 "other survivors". "Predicted survivors" were more likely to recover basic cognitive functions shortly after awakening (ability to follow a standardized neuropsychological battery: 86% vs. 44%; p=0.03 (Fisher)) and to show a very good functional outcome at 3 months (CPC 1: 86% vs. 33%; p=0.004 (Fisher)). Moreover, progression of auditory discrimination during coma was strongly correlated with cognitive performance on awakening (phonemic verbal fluency: rs=0.48; p=0.009 (Spearman)). Progression of auditory discrimination during coma provides early indication of future recovery of cognitive functions. The degree of improvement is informative of the degree of functional impairment. If confirmed in a larger cohort, this test would be the first to predict detailed outcome at the single-patient level. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Wang, Liangcheng; Matsunaga, Shigetaka; Mikami, Yukiko; Takai, Yasushi; Terui, Katsuo; Seki, Hiroyuki
2016-07-01
Placental abruption is a severe obstetric complication of pregnancy that can cause disseminated intravascular coagulation and progress to massive post-partum hemorrhage. Coagulation disorder due to extreme consumption of fibrinogen is considered the main pathogenesis of disseminated intravascular coagulation in patients with placental abruption. The present study sought to determine if the pre-delivery fibrinogen level could predict adverse maternal or neonatal outcomes in patients with placental abruption. This retrospective medical chart review was conducted in a center for maternal, fetal, and neonatal medicine in Japan with 61 patients with placental abruption. Fibrinogen levels prior to delivery were collected and evaluated for the prediction of maternal and neonatal outcomes. The main outcome measures for maternal outcomes were disseminated intravascular coagulation and hemorrhage, and the main outcome measures for neonatal outcomes were Apgar score at 5 min, umbilical artery pH, and stillbirth. The receiver-operator curve and multivariate logistic regression analyses indicated that fibrinogen significantly predicted overt disseminated intravascular coagulation and the requirement of ≥6 red blood cell units, ≥10 fresh frozen plasma units, and ≥20 fresh frozen plasma units for transfusion. Moderate hemorrhage occurred in 71.5% of patients with a decrease in fibrinogen levels to 155 mg/dL. Fibrinogen could also predict neonatal outcomes. Umbilical artery pH neonatal outcomes with placental abruption. © 2016 Japan Society of Obstetrics and Gynecology. © 2016 Japan Society of Obstetrics and Gynecology.
Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Ohashi, Takuya; Uematsu, Masaaki
2017-11-17
Before the discovery of contact-force guidance, eliminating pacing capture along the pulmonary vein (PV) isolation line had been reported to improve PV isolation durability and rhythm outcomes. DRAGON (UMIN-CTR, UMIN000015332) aimed to elucidate the efficacy of pace-capture-guided ablation following contact-force-guided PV isolation ablation in paroxysmal atrial fibrillation (AF) patients. A total of 156 paroxysmal AF patients with AF-trigger ectopies from any of the four PVs induced by isoproterenol were randomly assigned to undergo pace-capture-guided ablation along a contact-force-guided isolation line around AF-trigger PVs (PC group, n = 76) or contact-force-guided PV isolation ablation alone (control group, n = 80). Follow-up of at least 1 year commenced with serial 24 h Holter and symptom-triggered ambulatory monitoring. There was no significant difference in acute PV reconnection rates during a 20 min waiting period after the last ablation or adenosine infusion testing between the PC and the control groups (per patient, 21% vs. 27%, P = 0.27; per AF-trigger PV, 5.9% vs. 7.3%, P = 0.70; and per non-AF-trigger PV, 7.1% vs. 7.4%, P = 0.92). Atrial tachyarrhythmia-free survival rates off antiarrhythmic drugs after the initial session were comparable at 19.3 ± 6.2 months between the two groups (82% vs. 80%, P = 0.80). Among 22 patients who required a second ablation procedure, there was no difference between the PC and the control groups in the PV reconnection rates at both previously AF-trigger (29% vs. 43%, P = 0.70) and non-AF-trigger PVs (18% vs. 19%, P = 0.88). Pace-capture-guided ablation performed after contact-force-guided PV isolation demonstrated no improvement in PV isolation durability or rhythm outcome. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Field enhancement induced laser ablation
DEFF Research Database (Denmark)
Fiutowski, Jacek; Maibohm, Christian; Kjelstrup-Hansen, Jakob
Sub-diffraction spatially resolved, quantitative mapping of strongly localized field intensity enhancement on gold nanostructures via laser ablation of polymer thin films is reported. Illumination using a femtosecond laser scanning microscope excites surface plasmons in the nanostructures....... The accompanying field enhancement substantially lowers the ablation threshold of the polymer film and thus creates local ablation spots and corresponding topographic modifications of the polymer film. Such modifications are quantified straightforwardly via scanning electron and atomic force microscopy. Thickness...
Radiofrequency ablation in dermatology
Directory of Open Access Journals (Sweden)
Sachdeva Silonie
2007-01-01
Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.
Temporal dependence of the mass ablation rate in uv irradiated spherical targets
International Nuclear Information System (INIS)
Delettrez, J.; Jaanimagi, P.A.; Henke, B.L.; Richardson, M.C.
1985-01-01
In this talk, measurements of thermal transport in spherical geometry using time-resolved x-ray spectroscopy are presented. The time dependence of the mass ablation rate (m) is determined by following the progress of the ablation surface through thin layers of material embedded at various depths below the surface of the target. These measurements made with 6, 12 and 24 uv (351 nm) beams from OMEGA are compared to previous thermal transport data and are in qualitative agreement with detailed LILAC hydrodynamic code simulations which predict a sharp decrease in m after the peak of the laser pulse. Viewgraphs of the talk comprise the report
Percutaneous Microwave Ablation of Renal Angiomyolipomas
Energy Technology Data Exchange (ETDEWEB)
Cristescu, Mircea, E-mail: mcristescu@uwhealth.org [University of Wisconsin, Department of Radiology (United States); Abel, E. Jason, E-mail: abel@urology.wisc.edu [University of Wisconsin, Department of Urology (United States); Wells, Shane, E-mail: swells@uwhealth.org; Ziemlewicz, Timothy J., E-mail: tziemlewicz@uwhealth.org [University of Wisconsin, Department of Radiology (United States); Hedican, Sean P., E-mail: hedican@surgery.wisc.edu [University of Wisconsin, Department of Urology (United States); Lubner, Megan G., E-mail: mlubner@uwhealth.org; Hinshaw, J. Louis, E-mail: jhinshaw@uwhealth.org; Brace, Christopher L., E-mail: cbrace@uwhealth.org; Lee, Fred T., E-mail: flee@uwhealth.org [University of Wisconsin, Department of Radiology (United States)
2016-03-15
PurposeTo evaluate the safety and efficacy of US-guided percutaneous microwave (MW) ablation in the treatment of renal angiomyolipoma (AML).Materials and MethodsFrom January 2011 to April 2014, seven patients (5 females and 2 males; mean age 51.4) with 11 renal AMLs (9 sporadic type and 2 tuberous sclerosis associated) with a mean size of 3.4 ± 0.7 cm (range 2.4–4.9 cm) were treated with high-powered, gas-cooled percutaneous MW ablation under US guidance. Tumoral diameter, volume, and CT/MR enhancement were measured on pre-treatment, immediate post-ablation, and delayed post-ablation imaging. Clinical symptoms and creatinine were assessed on follow-up visits.ResultsAll ablations were technically successful and no major complications were encountered. Mean ablation parameters were ablation power of 65 W (range 60–70 W), using 456 mL of hydrodissection fluid per patient, over 4.7 min (range 3–8 min). Immediate post-ablation imaging demonstrated mean tumor diameter and volume decreases of 1.8 % (3.4–3.3 cm) and 1.7 % (27.5–26.3 cm{sup 3}), respectively. Delayed imaging follow-up obtained at a mean interval of 23.1 months (median 17.6; range 9–47) demonstrated mean tumor diameter and volume decreases of 29 % (3.4–2.4 cm) and 47 % (27.5–12.1 cm{sup 3}), respectively. Tumoral enhancement decreased on immediate post-procedure and delayed imaging by CT/MR parameters, indicating decreased tumor vascularity. No patients required additional intervention and no patients experienced spontaneous bleeding post-ablation.ConclusionOur early experience with high-powered, gas-cooled percutaneous MW ablation demonstrates it to be a safe and effective modality to devascularize and decrease the size of renal AMLs.
Transarterial ethanol ablation for sporadic and non-hemorrhaging angiomyolipoma in the kidney
International Nuclear Information System (INIS)
Takebayashi, Shigeo; Horikawa, Ayumi; Arai, Mito; Iso, Shinichiroh; Noguchi, Kazumi
2009-01-01
Purpose: We evaluated the efficacy and side effects of transarterial ethanol ablation in sporadic and non-hemorrhaging angiomyolipomas (AMLs) in the kidney. Material and Methods: A total of 10 patients with solitary and sporadic AMLs underwent selective transarterial absolute ethanol ablation for prophylaxis against hemorrhage. We confirmed the ratio areas of tumor vessel on angiogram, those of infraction on post-ablation computed tomography (CT) and those of tumor reduction in a 3-, 6- and 12-month follow-up CT. Results: Once or twice a single infusion of 1 or 2 ml absolute ethanol achieved in a total occlusion of 22 feeding arteries which consisted of 7 proximal interlobar arteries, 12 distal interlobar arteries and 3 renal capsular arteries. Nontarget occlusion did not occur by ethanol reflux in any cases but occurred causing spasms provoked by repeated inflation and deflation of the balloon in one case. Total occlusion of tumor vessels was observed in 7 patients and 92-95% occlusion in 3. Ethanol ablation produced 1.8-22.5% (mean 8.4 ± 6.8%) areas of infarctions but the outcome was not serious in all cases. Mean percentage areas of tumor reduction were 29.4 ± 10.6% in a 3-month follow-up, 45.7 ± 11.9% in a 6-month and 59.3 ± 11.5% in a 12-month follow-up. Conclusions: Absolute ethanol ablation for sporadic and non-hemorrhaging AML is safe and effective in reducing majority of tumor area in a 1-year follow-up.
Energy distribution of ions produced by laser ablation of silver in vacuum
International Nuclear Information System (INIS)
Toftmann, B.; Schou, J.; Canulescu, S.
2013-01-01
The ion energy in a silver ablation plume for fluence in the range of 0.6–2.4 J cm −2 , typical for a pulsed laser deposition (PLD) experiment has been investigated. In this fluence range the ion fraction of the ablated particles becomes gradually dominant and can be utilized to characterize the ablation process. A silver target in vacuum was irradiated with a Nd:YAG laser at a wavelength of 355 nm and detailed measurements of the time-resolved angular distribution of plume ions were made. In contrast to earlier work, the beam spot was circular such that any flip-over effect of the plume is avoided. The angular energy distribution of ions in forward direction exceeds values of 500 eV, while at large angles the ion energy tail is below 100 eV. The maximum for the time-of-flight distributions agrees consistently with the prediction of Anisimov's model in the low fluence range, in which hydrodynamic motion prevails.
Hairol, A O; Affirul, C A; Azlanudin, A; Zamri, Z; Razman, J; Choi, S Y
2017-01-01
Radiofrequency ablation (RFA) has evolved to become the treatment of choice for non-resectable recurrent colorectal liver metastasis. It is however, not without complications. Portal vein thrombosis following RFA is rare but can be fatal to the outcome of the patient. Here, we present a case of a 66-year-old man who developed portal vein thrombosis following RFA. CT scan revealed a left portal vein thrombosis. This case report highlights the challenges and multimodal treatment of portal vein thrombosis following Radiofrequency ablation (RFA) in a cirrhotic patient.
Endovascular Radiofrequency Ablation for Varicose Veins
2011-01-01
catheter) with ELT but mainly focused on peri-procedural outcomes such as pain, complications and recovery. Vein ablation rates were not evaluated in the trials, except for one small trial involving bilateral VV. Pain responses in patients undergoing ablation were extremely variable and up to 2 weeks, mean pain levels were significantly less with RFA than ELT ablation but differences were not significant at one month. Recovery, evaluated as return to usual activity or return to work, however, was similar in the treatment groups. Vein symptom and QOL improvements were improved in both groups but were significantly better in the RFA group than the ELT group at 2 weeks, but not at one month. Vein ablation rates were evaluated in several controlled clinical studies comparing the treatments between centers or within centers between individuals or over time. Comparisons in these studies were inconsistent with vein ablation rates for RFA reported to be similar to, higher than and lower than those with ELT. Economic Analysis RFA and surgical vein stripping, the main comparator reimbursed by the public system, are comparable in clinical benefits. Hence a cost-analysis was conducted to identify the differences in resources and costs between both procedures and a budgetary impact analysis (BIA) was conducted to project costs over a 5- year period in the province of Ontario. The target population of this economic analysis was patients with symptomatic varicose veins and the primary analytic perspective was that of the Ministry of Health and Long-Term Care. The average case cost (based on Ontario hospital costs and medical resources) for surgical vein stripping was estimated to be $1,799. In order to calculate a procedural cost for RFA it was assumed that the hospital cost and physician labour fees, excluding anaesthesia and surgical assistance, were the same as vein stripping surgery. The manufacturer also provided details on the generator with a capital cost of $27,500 and a lifespan
Temperature-controlled irrigated tip radiofrequency catheter ablation
DEFF Research Database (Denmark)
Petersen, H H; Chen, X; Pietersen, Adrian
1998-01-01
INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....
Micrometeoroid ablation simulated in the laboratory
Sternovsky, Zoltan; Thomas, Evan W.; DeLuca, Michael; Horanyi, Mihaly; Janches, Diego; Munsat, Tobin L.; Plane, John M. C.
2016-04-01
A facility is developed to simulate the ablation of micrometeoroids in laboratory conditions, which also allows measuring the ionization probability of the ablated material. An electrostatic dust accelerator is used to generate iron and meteoric analog particles with velocities 10-50 km/s. The particles are then introduced into a cell filled with nitrogen, air or carbon dioxide gas with pressures adjustable in the 0.02 - 0.5 Torr range, where the partial or complete ablation of the particle occurs over a short distance. An array of biased electrodes is used to collect the ionized products with spatial resolution along the ablating particles' path, allowing thus the study of the temporal resolution of the process. A simple ablation model is used to match the observations. For completely ablated particles the total collected charge directly yields the ionization efficiency for. The measurements using iron particles in N2 and air are in relatively good agreement with earlier data. The measurements with CO2 and He gases, however, are significantly different from the expectations.
Machine learning approach for the outcome prediction of temporal lobe epilepsy surgery.
Directory of Open Access Journals (Sweden)
Rubén Armañanzas
Full Text Available Epilepsy surgery is effective in reducing both the number and frequency of seizures, particularly in temporal lobe epilepsy (TLE. Nevertheless, a significant proportion of these patients continue suffering seizures after surgery. Here we used a machine learning approach to predict the outcome of epilepsy surgery based on supervised classification data mining taking into account not only the common clinical variables, but also pathological and neuropsychological evaluations. We have generated models capable of predicting whether a patient with TLE secondary to hippocampal sclerosis will fully recover from epilepsy or not. The machine learning analysis revealed that outcome could be predicted with an estimated accuracy of almost 90% using some clinical and neuropsychological features. Importantly, not all the features were needed to perform the prediction; some of them proved to be irrelevant to the prognosis. Personality style was found to be one of the key features to predict the outcome. Although we examined relatively few cases, findings were verified across all data, showing that the machine learning approach described in the present study may be a powerful method. Since neuropsychological assessment of epileptic patients is a standard protocol in the pre-surgical evaluation, we propose to include these specific psychological tests and machine learning tools to improve the selection of candidates for epilepsy surgery.
International Nuclear Information System (INIS)
Rhim, Hyunchul; Kim, Young-sun; Choi, Dongil; Lim, Hyo K.; Park, KoWoon
2008-01-01
This study investigated the reasons for some patients requiring two consecutive sessions of percutaneous radiofrequency (RF) ablation of hepatocellular carcinoma (HCC). We reviewed our database of 1,179 patients (1,624 treatments) with HCCs treated by percutaneous ultrasound (US)-guided RF ablation over 6 years. We retrospectively evaluated 80 patients who required a second session after the first session. The medical records and follow-up CTs were studied. We assessed the reasons for the second session and the patient outcomes. A second session was required in 80 (4.8%) out of 1,642 treatments of percutaneous RF ablation for HCC. The reason for the second session included technical failure related to the patient or the procedure (n=26), technical failure due to residual (n=40), newly detected (n=11) or missed (n=3) tumors found at the immediate follow-up CT. All patients were retreated with a second RFA session the next day. Seventy-five (93%) of 80 patients achieved complete ablation after the second session. The remaining five patients were treated by TACE (n=1), additional RFA (as second treatment at next admission) (n=3), or were lost to follow-up (n=1). After 1 month follow-up, 72 patients (96%) showed complete ablation after the second session. The interventional oncologist should understand the technical reasons for a patient requiring a second session of RF ablation when providing treatment for HCCs and perform careful pre-procedural planning to minimize the need for multi-session procedures. (orig.)
Neuropsychological outcomes following stereotactic laser amygdalohippocampectomy.
Greenway, Melanie R F; Lucas, John A; Feyissa, Anteneh M; Grewal, Sanjeet; Wharen, Robert E; Tatum, William O
2017-10-01
The objective was to analyze neuropsychological testing data from 15 patients before and after stereotactic laser ablation surgery for temporal lobe epilepsy and to describe the seizure outcomes after stereotactic laser ablation surgery. A retrospective review of 15 patients who underwent stereotactic laser ablation and who also underwent neuropsychological testing before and after surgery was performed. Verbal and visual memory was assessed in all 15 patients using California Verbal Learning Test and Wechsler Memory Scale IV. Naming was assessed in 9 of 15 patients using the Boston Naming Test. Statistical analysis was performed to determine clinically significant changes using previously validated reliable change indices and proprietary Advanced Clinical Solutions software. Seizure outcome data were evaluated using Engel classification. Postsurgery neuropsychological evaluation demonstrated that all 15 patients experienced at least 1 clinically significant decline in either verbal or visual memory. Ten patients in this series, including five with dominant-hemisphere surgery, demonstrated decline in delayed memory for narrative information (Logical Memory II). By contrast, the Boston Naming Test demonstrated more favorable results after surgery. Two of nine patients demonstrated a clinically significant increase in naming ability, and only one of nine patients demonstrated a clinically significant decline in naming ability. With at least 6months of follow-up after surgery, 33% reported seizure freedom. Stereotactic laser ablation can result in clinically significant and meaningful decline in verbal and visual memory when comparing patients to their own presurgical baseline. Naming ability, conversely, is much less likely to be impacted by stereotactic laser ablation and may improve after the procedure. Copyright © 2017 Elsevier Inc. All rights reserved.
Posterior urethra: Anterior urethra ratio in the evaluation of success following PUV ablation.
Babu, R; Hariharasudhan, S; Ramesh, C
2016-12-01
There are conflicting reports on the criteria with which to determine success following posterior urethral valve (PUV) ablation. The aims of this study were to assess the value of the posterior urethra: anterior urethra ratio (PAR) in predicting successful PUV ablation. All neonates and infants with confirmed PUV on voiding cystourethrogram (VCUG) were included. Initial PAR was computed by dividing maximum posterior urethral diameter by anterior urethral diameter. Distances were measured by an on-screen distance measurement tool in the Radiology department, to avoid error. Only oblique images with good voiding phases were used for assessment. All patients underwent cystoscopy and PUV ablation using cold knife. Postoperative VCUG and cystoscopy were performed at 3 months follow-up. Success was defined as cystoscopic resolution of obstruction, in addition to biochemical and radiological improvement, and this was compared with PAR findings. An equal number of age-matched control patients who had a normal VCUG (as a part of evaluation of antenatal hydronephrosis) were also analyzed. A total of 56 patients (median age 15 days, range 3-250 days) were analyzed between 2013 and 2016. The mean PAR was 1.5 (0.42) in controls and 3.42 (0.75) in those with PUV at diagnosis (P = 0.001). In those with successful PUV ablation (n = 51) the mean PAR was 1.8 (0.21), and in those with residual PUV/stricture (n = 5) the mean PAR was 3.16 (0.54). The difference between these two groups was statistically significant (P = 0.0001). Applying the value of mean + 2 SD of successful PUV ablation, an upper limit of PAR >2.2 was proposed to predict failure. Using this cut-off, 4/7 with PAR >2.2 had confirmed failure, while 48/49 with PAR posterior urethra is more than 2.2 times the diameter of the anterior urethra (PAR >2.2) on repeat VCUG following a PUV ablation, a cystoscopy check is essential to rule out residual PUV/stricture. Copyright © 2016 Journal of Pediatric Urology
Sphenopalatine ganglion: block, radiofrequency ablation and neurostimulation - a systematic review.
Ho, Kwo Wei David; Przkora, Rene; Kumar, Sanjeev
2017-12-28
Sphenopalatine ganglion is the largest collection of neurons in the calvarium outside of the brain. Over the past century, it has been a target for interventional treatment of head and facial pain due to its ease of access. Block, radiofrequency ablation, and neurostimulation have all been applied to treat a myriad of painful syndromes. Despite the routine use of these interventions, the literature supporting their use has not been systematically summarized. This systematic review aims to collect and summarize the level of evidence supporting the use of sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Studies included in this review were compiled and analyzed for their treated medical conditions, study design, outcomes and procedural details. Studies were graded using Oxford Center for Evidence-Based Medicine for level of evidence. Based on the level of evidence, grades of recommendations are provided for each intervention and its associated medical conditions. Eighty-three publications were included in this review, of which 60 were studies on sphenopalatine ganglion block, 15 were on radiofrequency ablation, and 8 were on neurostimulation. Of all the studies, 23 have evidence level above case series. Of the 23 studies, 19 were on sphenopalatine ganglion block, 1 study on radiofrequency ablation, and 3 studies on neurostimulation. The rest of the available literature was case reports and case series. The strongest evidence lies in using sphenopalatine ganglion block, radiofrequency ablation and neurostimulation for cluster headache. Sphenopalatine ganglion block also has evidence in treating trigeminal neuralgia, migraines, reducing the needs of analgesics after endoscopic sinus surgery and reducing pain associated with nasal packing
How to perform posterior wall isolation in catheter ablation for atrial fibrillation.
Sugumar, Hariharan; Thomas, Stuart P; Prabhu, Sandeep; Voskoboinik, Aleksandr; Kistler, Peter M
2018-02-01
Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described. © 2017 Wiley Periodicals, Inc.
Mansilla, Alberto V; Bivins, Eugene E; Contreras, Francisco; Hernandez, Manuel A; Kohler, Nathan; Pepe, Julie W
2017-02-01
To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors. Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30-89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2-4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor. Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9-46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ 2 = 12.073, df = 2, P = .002). The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Cryoballoon Ablation for Atrial Fibrillation
Directory of Open Access Journals (Sweden)
Jason G. Andrade, MD
2012-03-01
Full Text Available Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1 the rationale for adjunctive imaging, 2 selection of an appropriate cryoballoon size, 3 predictors of efficacy, 4 advanced trouble-shooting techniques, and 5 strategies to reduce procedural complications, such as phrenic nerve palsy.
Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.
Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H
2016-05-01
Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.
Preoperative MRI findings predict two-year postoperative clinical outcome in lumbar spinal stenosis.
Directory of Open Access Journals (Sweden)
Pekka Kuittinen
Full Text Available To study the predictive value of preoperative magnetic resonance imaging (MRI findings for the two-year postoperative clinical outcome in lumbar spinal stenosis (LSS.84 patients (mean age 63±11 years, male 43% with symptoms severe enough to indicate LSS surgery were included in this prospective observational single-center study. Preoperative MRI of the lumbar spine was performed with a 1.5-T unit. The imaging protocol conformed to the requirements of the American College of Radiology for the performance of MRI of the adult spine. Visual and quantitative assessment of MRI was performed by one experienced neuroradiologist. At the two-year postoperative follow-up, functional ability was assessed with the Oswestry Disability Index (ODI 0-100% and treadmill test (0-1000 m, pain symptoms with the overall Visual Analogue Scale (VAS 0-100 mm, and specific low back pain (LBP and specific leg pain (LP separately with a numeric rating scale from 0-10 (NRS-11. Satisfaction with the surgical outcome was also assessed.Preoperative severe central stenosis predicted postoperatively lower LP, LBP, and VAS when compared in patients with moderate central stenosis (p<0.05. Moreover, severe stenosis predicted higher postoperative satisfaction (p = 0.029. Preoperative scoliosis predicted an impaired outcome in the ODI (p = 0.031 and lowered the walking distance in the treadmill test (p = 0.001. The preoperative finding of only one stenotic level in visual assessment predicted less postoperative LBP when compared with patients having 2 or more stenotic levels (p = 0.026. No significant differences were detected between quantitative measurements and the patient outcome.Routine preoperative lumbar spine MRI can predict the patient outcome in a two-year follow up in patients with LSS surgery. Severe central stenosis and one-level central stenosis are predictors of good outcome. Preoperative finding of scoliosis may indicate worse functional ability.
Translational medicine in the field of ablative fractional laser (AFXL)-assisted drug delivery
DEFF Research Database (Denmark)
Haedersdal, Merete; Erlendsson, Andrés M; Paasch, Uwe
2016-01-01
Ablative fractional lasers enhance uptake of topical therapeutics and the concept of fractional laser-assisted drug delivery has now been taken into clinical practice. Objectives We systematically reviewed preclinical data and clinical evidence for fractional lasers to enhance drug uptake...... level of evidence was reached for actinic keratoses treated with methylaminolevulinate for photodynamic therapy (level IB, 5 randomized controlled trials), substantiating superior and long-lasting efficacy versus conventional photodynamic therapy. No adverse events were reported, but ablative fractional...... laser-assisted drug delivery implies risks of systemic drug absorption, especially when performed over large skin areas. Conclusions Fractional laser-assisted drug delivery is beneficial in enhancing preclinical and clinical outcomes for certain skin conditions....
Early prediction of outcome of activities of daily living after stroke: a systematic review
Veerbeek, J.M.; Kwakkel, G.; Wegen, van, E.E.H.; Ket, J.C.F.; Heijmans, M.W.
2011-01-01
BACKGROUND AND PURPOSE-Knowledge about robust and unbiased factors that predict outcome of activities of daily living (ADL) is paramount in stroke management. This review investigates the methodological quality of prognostic studies in the early poststroke phase for final ADL to identify variables that are predictive or not predictive for outcome of ADL after stroke. METHODS-PubMed, Ebsco/Cinahl and Embase were systematically searched for prognostic studies in which stroke patients were inclu...
DEFF Research Database (Denmark)
Kümler, Iben; Parner, Vibeke Kirk; Tuxen, Malgorzata K.
2015-01-01
PURPOSE: Despite improved anti-neoplastic treatment the prognosis for patients with liver metastases from metastatic breast cancer remains poor. MATERIALS AND METHODS: Thirty-two consecutive patients with metastatic breast cancer treated with radiofrequency ablation (RFA) at the Department of Onc...
Jeffery, Alvin D
2015-06-01
The expansion of real-time analytic abilities within current electronic health records has led to innovations in predictive modeling and clinical decision support systems. However, the ability of these systems to influence patient outcomes is currently unknown. Even though nurses are the largest profession within the healthcare workforce, little research has been performed to explore the impact of clinical decision support on their decisions and the patient outcomes associated with them. A scoping literature review explored the impact clinical decision support systems containing healthcare predictive analytics have on four nursing-sensitive patient outcomes (pressure ulcers, failure to rescue, falls, and infections). While many articles discussed variable selection and predictive model development/validation, only four articles examined the impact on patient outcomes. The novelty of predictive analytics and the inherent methodological challenges in studying clinical decision support impact are likely responsible for this paucity of literature. Major methodological challenges include (1) multilevel nature of intervention, (2) treatment fidelity, and (3) adequacy of clinicians' subsequent behavior. There is currently insufficient evidence to demonstrate efficacy of healthcare predictive analytics-enhanced clinical decision support systems on nursing-sensitive patient outcomes. Innovative research methods and a greater emphasis on studying this phenomenon are needed.
Towards nanopatterning by femtosecond laser ablation of pre-stretched elastomers
Energy Technology Data Exchange (ETDEWEB)
Surdo, Salvatore; Piazza, Simonluca; Ceseracciu, Luca; Diaspro, Alberto; Duocastella, Martí, E-mail: marti.duocastella@iit.it
2016-06-30
Graphical abstract: - Highlights: • We present a new approach to increase the focusing capabilities of optical systems. • Laser patterning is performed over a stretched elastomeric membrane. • After releasing stress, patterns shrink according to the applied strain. • Minimum feature size is controlled by strain, enabling sub-diffraction patterning. - Abstract: Diffraction limits the focusing capabilities of an optical system seriously constraining the use of lasers for nanopatterning. In this work, we present a novel and simple approach to reduce the minimum feature size of a laser-direct write system by ablating a pre-stretched material. In particular, by focusing and scanning a femtosecond laser beam on the surface of a uniaxially pre-stretched elastomeric membrane we are able to obtain microstructures according to a desired pattern. After removing the stress applied to the elastomer, the membrane relaxes to its original size and the ablated patterns shrink while preserving their shape. In this way, the minimum feature size that is typically determined by the optical properties of the focusing system can be now controlled by the strain applied to the elastomer during the ablation process. We demonstrate this approach by ablating lines on a stretchable polymeric membrane at different strain conditions. Experimental results are in good agreement with theoretical predictions. The proposed method opens up new interesting possibilities for the rapid prototyping of micro- and nano-structures suitable for a wide range of applications such as soft-lithography, micro-/nano-fluidics and lab-on-chip.
Towards nanopatterning by femtosecond laser ablation of pre-stretched elastomers
International Nuclear Information System (INIS)
Surdo, Salvatore; Piazza, Simonluca; Ceseracciu, Luca; Diaspro, Alberto; Duocastella, Martí
2016-01-01
Graphical abstract: - Highlights: • We present a new approach to increase the focusing capabilities of optical systems. • Laser patterning is performed over a stretched elastomeric membrane. • After releasing stress, patterns shrink according to the applied strain. • Minimum feature size is controlled by strain, enabling sub-diffraction patterning. - Abstract: Diffraction limits the focusing capabilities of an optical system seriously constraining the use of lasers for nanopatterning. In this work, we present a novel and simple approach to reduce the minimum feature size of a laser-direct write system by ablating a pre-stretched material. In particular, by focusing and scanning a femtosecond laser beam on the surface of a uniaxially pre-stretched elastomeric membrane we are able to obtain microstructures according to a desired pattern. After removing the stress applied to the elastomer, the membrane relaxes to its original size and the ablated patterns shrink while preserving their shape. In this way, the minimum feature size that is typically determined by the optical properties of the focusing system can be now controlled by the strain applied to the elastomer during the ablation process. We demonstrate this approach by ablating lines on a stretchable polymeric membrane at different strain conditions. Experimental results are in good agreement with theoretical predictions. The proposed method opens up new interesting possibilities for the rapid prototyping of micro- and nano-structures suitable for a wide range of applications such as soft-lithography, micro-/nano-fluidics and lab-on-chip.
Attitudes Towards Catheter Ablation for Atrial Fibrillation
DEFF Research Database (Denmark)
Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis
2015-01-01
BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...
Noninvasive work of breathing improves prediction of post-extubation outcome.
Banner, Michael J; Euliano, Neil R; Martin, A Daniel; Al-Rawas, Nawar; Layon, A Joseph; Gabrielli, Andrea
2012-02-01
We hypothesized that non-invasively determined work of breathing per minute (WOB(N)/min) (esophageal balloon not required) may be useful for predicting extubation outcome, i.e., appropriate work of breathing values may be associated with extubation success, while inappropriately increased values may be associated with failure. Adult candidates for extubation were divided into a training set (n = 38) to determine threshold values of indices for assessing extubation and a prospective validation set (n = 59) to determine the predictive power of the threshold values for patients successfully extubated and those who failed extubation. All were evaluated for extubation during a spontaneous breathing trial (5 cmH(2)O pressure support ventilation, 5 cmH(2)O positive end expiratory pressure) using routine clinical practice standards. WOB(N)/min data were blinded to attending physicians. Area under the receiver operating characteristic curves (AUC), sensitivity, specificity, and positive and negative predictive values of all extubation indices were determined. AUC for WOB(N)/min was 0.96 and significantly greater (p indices. WOB(N)/min had a specificity of 0.83, the highest sensitivity at 0.96, positive predictive value at 0.84, and negative predictive value at 0.96 compared to all indices. For 95% of those successfully extubated, WOB(N)/min was ≤10 J/min. WOB(N)/min had the greatest overall predictive accuracy for extubation compared to traditional indices. WOB(N)/min warrants consideration for use in a complementary manner with spontaneous breathing pattern data for predicting extubation outcome.
Prediction modelling for trauma using comorbidity and 'true' 30-day outcome.
Bouamra, Omar; Jacques, Richard; Edwards, Antoinette; Yates, David W; Lawrence, Thomas; Jenks, Tom; Woodford, Maralyn; Lecky, Fiona
2015-12-01
Prediction models for trauma outcome routinely control for age but there is uncertainty about the need to control for comorbidity and whether the two interact. This paper describes recent revisions to the Trauma Audit and Research Network (TARN) risk adjustment model designed to take account of age and comorbidities. In addition linkage between TARN and the Office of National Statistics (ONS) database allows patient's outcome to be accurately identified up to 30 days after injury. Outcome at discharge within 30 days was previously used. Prospectively collected data between 2010 and 2013 from the TARN database were analysed. The data for modelling consisted of 129 786 hospital trauma admissions. Three models were compared using the area under the receiver operating curve (AuROC) for assessing the ability of the models to predict outcome, the Akaike information criteria to measure the quality between models and test for goodness-of-fit and calibration. Model 1 is the current TARN model, Model 2 is Model 1 augmented by a modified Charlson comorbidity index and Model 3 is Model 2 with ONS data on 30 day outcome. The values of the AuROC curve for Model 1 were 0.896 (95% CI 0.893 to 0.899), for Model 2 were 0.904 (0.900 to 0.907) and for Model 3 0.897 (0.896 to 0.902). No significant interaction was found between age and comorbidity in Model 2 or in Model 3. The new model includes comorbidity and this has improved outcome prediction. There was no interaction between age and comorbidity, suggesting that both independently increase vulnerability to mortality after injury. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Zon-Rabelink, I.A.A. van; Vleugels, M.P.; Merkus, J.M.W.M.; Graaf, R.M. de
2003-01-01
OBJECTIVE: To compare two methods of endometrial ablation, hysteroscopic rollerball electrocoagulation (RBE) and non-hysteroscopic uterine balloon thermal (UBT) ablation (Thermachoice), regarding intra- and post-operative technical complications and safety aspects. STUDY DESIGN: A randomised
Cho, Suhyun; Choi, Min Ju; Zheng, Zhenlong; Goo, Boncheol; Kim, Do-Young; Cho, Sung Bin
2013-04-01
Both ablative and non-ablative fractional lasers have been applied to various uncommon hair disorders. The purpose of this study was to demonstrate the clinical effects of fractional laser therapy on the course of primary follicular and perifollicular pathologies and subsequent hair regrowth. A retrospective review of 17 patients with uncommon hair disorders - including ophiasis, autosomal recessive woolly hair/hypotrichosis, various secondary cicatricial alopecias, pubic hypotrichosis, frontal fibrosing alopecia, and perifolliculitis abscedens et suffodiens - was conducted. All patients had been treated with non-ablative and/or ablative fractional laser therapies. The mean clinical improvement score in these 17 patients was 2.2, while the mean patient satisfaction score was 2.5. Of the 17 subjects, 12 (70.6%) demonstrated a clinical response to non-ablative and/or ablative fractional laser treatments, including individuals with ophiasis, autosomal recessive woolly hair/hypotrichosis, secondary cicatricial alopecia (scleroderma and pressure-induced alopecia), frontal fibrosing alopecia, and perifolliculitis abscedens et suffodiens. Conversely, patients with long-standing ophiasis, surgical scar-induced secondary cicatricial alopecia, and pubic hypotrichosis did not respond to fractional laser therapy. Our findings demonstrate that the use of non-ablative and/or ablative fractional lasers promoted hair growth in certain cases of uncommon hair disorders without any remarkable side effects.
Schneider, Hauke; Huynh, Thien J; Demchuk, Andrew M; Dowlatshahi, Dar; Rodriguez-Luna, David; Silva, Yolanda; Aviv, Richard; Dzialowski, Imanuel
2018-06-01
The intracerebral hemorrhage (ICH) score is the most commonly used grading scale for stratifying functional outcome in patients with acute ICH. We sought to determine whether a combination of the ICH score and the computed tomographic angiography spot sign may improve outcome prediction in the cohort of a prospective multicenter hemorrhage trial. Prospectively collected data from 241 patients from the observational PREDICT study (Prediction of Hematoma Growth and Outcome in Patients With Intracerebral Hemorrhage Using the CT-Angiography Spot Sign) were analyzed. Functional outcome at 3 months was dichotomized using the modified Rankin Scale (0-3 versus 4-6). Performance of (1) the ICH score and (2) the spot sign ICH score-a scoring scale combining ICH score and spot sign number-was tested. Multivariable analysis demonstrated that ICH score (odds ratio, 3.2; 95% confidence interval, 2.2-4.8) and spot sign number (n=1: odds ratio, 2.7; 95% confidence interval, 1.1-7.4; n>1: odds ratio, 3.8; 95% confidence interval, 1.2-17.1) were independently predictive of functional outcome at 3 months with similar odds ratios. Prediction of functional outcome was not significantly different using the spot sign ICH score compared with the ICH score alone (spot sign ICH score area under curve versus ICH score area under curve: P =0.14). In the PREDICT cohort, a prognostic score adding the computed tomographic angiography-based spot sign to the established ICH score did not improve functional outcome prediction compared with the ICH score. © 2018 American Heart Association, Inc.
Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin
2017-05-01
To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p renal parenchyma volume preservation (89.19 vs 84.27%, p renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.
Writing Abilities Longitudinally Predict Academic Outcomes of Adolescents with ADHD
Molitor, Stephen J.; Langberg, Joshuah M.; Bourchtein, Elizaveta; Eddy, Laura D.; Dvorsky, Melissa R.; Evans, Steven W.
2016-01-01
Students with ADHD often experience a host of negative academic outcomes and deficits in reading and mathematics abilities contribute to these academic impairments. Students with ADHD may also have difficulties with written expression but there has been minimal research in this area and it is not clear whether written expression abilities uniquely contribute to the academic functioning of students with ADHD. The current study included a sample of 104 middle school students diagnosed with ADHD (grades 6–8). Participants were followed longitudinally to evaluate whether written expression abilities at baseline predicted student GPA and parent ratings of academic impairment 18 months later, after controlling for reading ability and additional relevant covariates. Written expression abilities longitudinally predicted both academic outcomes above and beyond ADHD and ODD symptoms, medication use, reading ability, and baseline values of GPA and parent-rated academic impairment. Follow-up analyses revealed that no single aspect of written expression was demonstrably more impactful on academic outcomes than the others, suggesting that writing as an entire process should be the focus of intervention. PMID:26783650
Hijdra, A.; van Gijn, J.; Nagelkerke, N. J.; Vermeulen, M.; van Crevel, H.
1988-01-01
Using logistic regression, we analyzed the predictive value of a number of entry variables with respect to the outcome variables delayed cerebral ischemia, rebleeding, and poor outcome (death or severe disability) in patients with aneurysmal subarachnoid hemorrhage. The entry variables were clinical
Cryoballoon Catheter Ablation in Atrial Fibrillation
Directory of Open Access Journals (Sweden)
Cevher Ozcan
2011-01-01
Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.
International Nuclear Information System (INIS)
Kim, Seung Kwon; Lim, Hyo K; Ryu, Jeong Ah
2004-01-01
We wished to evaluate the effect of the Pringle maneuver (occlusion of both the hepatic artery and portal vein) on the pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone in rabbit livers. Radiofrequency (RF) ablation zones were created in the livers of 24 rabbits in vivo by using a 50-W, 480-kHz monopolar RF generator and a 15-gauge expandable electrode with four sharp prongs for 7 mins. The tips of the electrodes were placed in the liver parenchyma near the porta hepatis with the distal 1 cm of their prongs deployed. Radiofrequency ablation was performed in the groups with (n=12 rabbits) and without (n=12 rabbits) the Pringle maneuver. Three animals of each group were sacrificed immediately, three days (the acute phase), seven days (the early subacute phase) and two weeks (the late subacute phase) after RF ablation. The ablation zones were excised and serial pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone were evaluated. With the Pringle maneuver, portal vein thrombosis was found in three cases (in the immediate [n=2] and acute phase [n=1]), bile duct dilatation adjacent to the ablation zone was found in one case (in the late subacute phase [n=1]), infarction adjacent to the ablation zone was found in three cases (in the early subacute [n=2] and late subacute [n=1] phases). None of the above changes was found in the livers ablated without the Pringle maneuver. On the microscopic findings, centrilobular congestion, sinusoidal congestion, sinusoidal platelet and neutrophilic adhesion, and hepatocyte vacuolar and ballooning changes in liver ablated with Pringle maneuver showed more significant changes than in those livers ablated without the Pringle maneuver (ρ < 0.05). Radiofrequency ablation with the Pringle maneuver created more severe pathologic changes in the portal vein, bile ducts and liver parenchyma surrounding the ablation zone compared with RF
Do treatment quality indicators predict cardiovascular outcomes in patients with diabetes?
Directory of Open Access Journals (Sweden)
Grigory Sidorenkov
Full Text Available BACKGROUND: Landmark clinical trials have led to optimal treatment recommendations for patients with diabetes. Whether optimal treatment is actually delivered in practice is even more important than the efficacy of the drugs tested in trials. To this end, treatment quality indicators have been developed and tested against intermediate outcomes. No studies have tested whether these treatment quality indicators also predict hard patient outcomes. METHODS: A cohort study was conducted using data collected from >10.000 diabetes patients in the Groningen Initiative to Analyze Type 2 Treatment (GIANTT database and Dutch Hospital Data register. Included quality indicators measured glucose-, lipid-, blood pressure- and albuminuria-lowering treatment status and treatment intensification. Hard patient outcome was the composite of cardiovascular events and all-cause death. Associations were tested using Cox regression adjusting for confounding, reporting hazard ratios (HR with 95% confidence intervals. RESULTS: Lipid and albuminuria treatment status, but not blood pressure lowering treatment status, were associated with the composite outcome (HR = 0.77, 0.67-0.88; HR = 0.75, 0.59-0.94. Glucose lowering treatment status was associated with the composite outcome only in patients with an elevated HbA1c level (HR = 0.72, 0.56-0.93. Treatment intensification with glucose-lowering but not with lipid-, blood pressure- and albuminuria-lowering drugs was associated with the outcome (HR = 0.73, 0.60-0.89. CONCLUSION: Treatment quality indicators measuring lipid- and albuminuria-lowering treatment status are valid quality measures, since they predict a lower risk of cardiovascular events and mortality in patients with diabetes. The quality indicators for glucose-lowering treatment should only be used for restricted populations with elevated HbA1c levels. Intriguingly, the tested indicators for blood pressure-lowering treatment did not predict patient
An evolution of trauma care evaluation: A thesis on trauma registry and outcome prediction models
Joosse, P.
2013-01-01
Outcome prediction models play an invaluable role in the evaluation and improvement of modern trauma care. Trauma registries underlying these outcome prediction models need to be accurate, complete and consistent. This thesis focused on the opportunities and limitations of trauma registries and
Winder, Anthony J.; Siemonsen, Susanne; Flottmann, Fabian; Fiehler, Jens; Forkert, Nils D.
2017-03-01
Voxel-based tissue outcome prediction in acute ischemic stroke patients is highly relevant for both clinical routine and research. Previous research has shown that features extracted from baseline multi-parametric MRI datasets have a high predictive value and can be used for the training of classifiers, which can generate tissue outcome predictions for both intravenous and conservative treatments. However, with the recent advent and popularization of intra-arterial thrombectomy treatment, novel research specifically addressing the utility of predictive classi- fiers for thrombectomy intervention is necessary for a holistic understanding of current stroke treatment options. The aim of this work was to develop three clinically viable tissue outcome prediction models using approximate nearest-neighbor, generalized linear model, and random decision forest approaches and to evaluate the accuracy of predicting tissue outcome after intra-arterial treatment. Therefore, the three machine learning models were trained, evaluated, and compared using datasets of 42 acute ischemic stroke patients treated with intra-arterial thrombectomy. Classifier training utilized eight voxel-based features extracted from baseline MRI datasets and five global features. Evaluation of classifier-based predictions was performed via comparison to the known tissue outcome, which was determined in follow-up imaging, using the Dice coefficient and leave-on-patient-out cross validation. The random decision forest prediction model led to the best tissue outcome predictions with a mean Dice coefficient of 0.37. The approximate nearest-neighbor and generalized linear model performed equally suboptimally with average Dice coefficients of 0.28 and 0.27 respectively, suggesting that both non-linearity and machine learning are desirable properties of a classifier well-suited to the intra-arterial tissue outcome prediction problem.
Reddy, Yeruva Madhu; Gunda, Sampath; Vallakati, Ajay; Kanmanthareddy, Arun; Pillarisetti, Jayasree; Atkins, Donita; Bommana, Sudharani; Emert, Martin P; Pimentel, Rhea; Dendi, Raghuveer; Berenbom, Loren D; Lakkireddy, Dhanunjaya
2015-09-15
Atrioventricular node (AVN) ablation is an effective treatment for symptomatic patients with atrial arrhythmias who are refractory to rhythm and rate control strategies where optimal ventricular rate control is desired. There are limited data on the predictors of failure of AVN ablation. Our objective was to identify the predictors of failure of AVN ablation. This is an observational single-center study of consecutive patients who underwent AVN ablation in a large academic center. Baseline characteristics, procedural variables, and outcomes of AVN ablation were collected. AVN "ablation failure" was defined as resumption of AVN conduction resulting in recurrence of either rapid ventricular response or suboptimal biventricular pacing. A total of 247 patients drug refractory AF who underwent AVN ablation at our center with a mean age of 71 ± 12 years with 46% being males were included. Ablation failure was seen in 11 (4.5%) patients. There were no statistical differences between patients with "ablation failure" versus "ablation success" in any of the baseline clinical variables. Patients with moderate-to-severe tricuspid regurgitation (TR) were much more likely to have ablation failure than those with ablation success (8 [73%] vs 65 [27%]; p = 0.003). All 11 patients with ablation failure had a successful redo procedure, 9 with right and 2 with the left sided approach. On multivariate analysis, presence of moderate-to-severe TR was found to be the only predictor of failure of AVN ablation (odds ratio 9.1, confidence interval 1.99 to 42.22, p = 0.004). In conclusion, moderate-to-severe TR is a strong and independent predictor of failure of AVN ablation. Copyright © 2015 Elsevier Inc. All rights reserved.
Polin, Baptiste; Behar, Nathalie; Galand, Vincent; Auffret, Vincent; Behaghel, Albin; Pavin, Dominique; Daubert, Jean-Claude; Mabo, Philippe; Leclercq, Christophe; Martins, Raphael P
2017-10-15
Atrioventricular node (AVN) ablation is usually a simple procedure but may sometimes be challenging. We aimed at identifying pre-procedural clinical predictors of challenging AVN ablation. Patients referred for AVN ablation from 2009 to 2015 were retrospectively included. Baseline clinical data, procedural variables and outcomes of AVN ablation were collected. A "challenging procedure" was defined 1) total radiofrequency delivery to get persistent AVN block≥400s, 2) need for left-sided arterial approach or 3) failure to obtain AVN ablation. 200 patients were included (71±10years). A total of 37 (18.5%) patients had "challenging" procedures (including 9 failures, 4.5%), while 163 (81.5%) had "non-challenging" ablations. In multivariable analysis, male sex (Odds ratio (OR)=4.66, 95% confidence interval (CI): 1.74-12.46), body mass index (BMI, OR=1.08 per 1kg/m 2 , 95%CI 1.01-1.16), operator experience (OR=0.40, 95%CI 0.17-0.94), and moderate-to-severe tricuspid regurgitation (TR, OR=3.65, 95%CI 1.63-8.15) were significant predictors of "challenging" ablations. The proportion as a function of number of predictors was analyzed (from 0 to 4, including male sex, operator inexperience, a BMI>23.5kg/m 2 and moderate-to-severe TR). There was a gradual increase in the risk of "challenging" procedure with the number of predictors by patient (No predictor: 0%; 1 predictor: 6.3%; 2 predictors: 16.5%; 3 predictors: 32.5%; 4 predictors: 77.8%). Operator experience, male sex, higher BMI and the degree of TR were independent predictors of "challenging" AVN ablation procedure. The risk increases with the number of predictors by patient. Copyright © 2017. Published by Elsevier B.V.
Bunch, T Jared; May, Heidi T; Bair, Tami L; Anderson, Jeffrey L; Crandall, Brian G; Cutler, Michael J; Jacobs, Victoria; Mallender, Charles; Muhlestein, Joseph B; Osborn, Jeffrey S; Weiss, J Peter; Day, John D
2015-12-01
There are a paucity of data about the long-term natural history of adult Wolff-Parkinson-White syndrome (WPW) patients in regard to risk of mortality and atrial fibrillation. We sought to describe the long-term outcomes of WPW patients and ascertain the impact of ablation on the natural history. Three groups of patients were studied: 2 WPW populations (ablation: 872, no ablation: 1461) and a 1:5 control population (n=11 175). Long-term mortality and atrial fibrillation rates were determined. The average follow-up for the WPW group was 7.9±5.9 (median: 6.9) years and was similar between the ablation and nonablation groups. Death rates were similar between the WPW group versus the control group (hazard ratio, 0.96; 95% confidence interval, 0.83-1.11; P=0.56). Nonablated WPW patients had a higher long-term death risk compared with ablated WPW patients (hazard ratio, 2.10; 95% confidence interval: 1.50-20.93; P<0.0001). Incident atrial fibrillation risk was higher in the WPW group compared with the control population (hazard ratio, 1.55; 95% confidence interval, 1.29-1.87; P<0.0001). Nonablated WPW patients had lower risk than ablated patients (hazard ratio, 0.39; 95% confidence interval, 0.28-0.53; P<0.0001). Long-term mortality rates in WPW patients are low and similar to an age-matched and gender-matched control population. WPW patients that underwent the multifactorial process of ablation had a lower mortality compared to nonablated WPW patients. Atrial fibrillation rates are high long-term, and ablation does not reduce this risk. © 2015 American Heart Association, Inc.
Predicting an Optimal Outcome after Radical Prostatectomy: The “Trifecta” Nomogram
Eastham, James A.; Scardino, Peter T.; Kattan, Michael W.
2014-01-01
Purpose The optimal outcome after radical prostatectomy (RP) for clinically localized prostate cancer is freedom from biochemical recurrence (BCR) along with recovery of continence and erectile function, a so-called trifecta. We evaluated our series of open radical prostatectomy patients to determine the likelihood of this outcome and to develop a nomogram predicting the trifecta. Material and Methods We reviewed records of patients undergoing open RP for clinical stage T1c–T3a prostate cancer at our center during 2000–2006. Men were excluded if they received preoperative hormonal therapy, chemotherapy, or radiation therapy; if their pre-treatment PSA was >50 ng/ml; or if they were impotent or incontinent before RP; 1577 men were included in the study. Freedom from BCR was defined as post-RP PSA <0.2 ng/ml. Continence was defined as not having to wear any protective pads. Potency was defined as erections adequate for intercourse on the majority of attempts, with or without a phosphodiesterase-5 inhibitor. Results Mean patient age was 58 years and mean pretreatment PSA was 6.4 ng/ml. A trifecta outcome (cancer-free status with recovery of continence and potency) was achieved in 62% of patients. In a nomogram developed to predict the likelihood of the trifecta, baseline PSA was the major predictive factor. The area under the receiver operating characteristic curve for the nomogram was 0.773, and calibration appeared excellent. Conclusions A trifecta (optimal) outcome can be achieved in the majority of men undergoing RP. The nomogram will permit patients to estimate preoperatively their likelihood of an optimal outcome after RP. PMID:18423693
CT-guided radiofrequency ablation of T1a renal cell carcinma in Korea; Mid-erm outcomes
Energy Technology Data Exchange (ETDEWEB)
Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)
2016-09-15
To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.
CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes
Energy Technology Data Exchange (ETDEWEB)
Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of)
2016-11-01
To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.
CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes
International Nuclear Information System (INIS)
Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo
2016-01-01
To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m 2 (14.2–142.7 mL/min/1.73 m 2 ) and 72.0 mL/min/1.73 m 2 (7.2–112.6 mL/min/1.73 m 2 ), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes
Matsen, Frederick A; Russ, Stacy M; Vu, Phuong T; Hsu, Jason E; Lucas, Robert M; Comstock, Bryan A
2016-11-01
Although shoulder arthroplasties generally are effective in improving patients' comfort and function, the results are variable for reasons that are not well understood. We posed two questions: (1) What factors are associated with better 2-year outcomes after shoulder arthroplasty? (2) What are the sensitivities, specificities, and positive and negative predictive values of a multivariate predictive model for better outcome? Three hundred thirty-nine patients having a shoulder arthroplasty (hemiarthroplasty, arthroplasty for cuff tear arthropathy, ream and run arthroplasty, total shoulder or reverse total shoulder arthroplasty) between August 24, 2010 and December 31, 2012 consented to participate in this prospective study. Two patients were excluded because they were missing baseline variables. Forty-three patients were missing 2-year data. Univariate and multivariate analyses determined the relationship of baseline patient, shoulder, and surgical characteristics to a "better" outcome, defined as an improvement of at least 30% of the maximal possible improvement in the Simple Shoulder Test. The results were used to develop a predictive model, the accuracy of which was tested using a 10-fold cross-validation. After controlling for potentially relevant confounding variables, the multivariate analysis showed that the factors significantly associated with better outcomes were American Society of Anesthesiologists Class I (odds ratio [OR], 1.94; 95% CI, 1.03-3.65; p = 0.041), shoulder problem not related to work (OR, 5.36; 95% CI, 2.15-13.37; p factors listed above. The area under the receiver operating characteristic curve generated from the cross-validated enhanced predictive model was 0.79 (generally values of 0.7 to 0.8 are considered fair and values of 0.8 to 0.9 are considered good). The false-positive fraction and the true-positive fraction depended on the cutoff probability selected (ie, the selected probability above which the prediction would be classified as
Energy Technology Data Exchange (ETDEWEB)
Jin, Gong Yong; Han, Young Min; Lim, Yeong Su; Jang, Kyu Yun; Lee, Sang Yong; Chung, Gyung Ho [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)
2004-05-01
To evaluate the radiologic findings for complete and partial ablation after percutaneous CT-guided transthoracic radiofrequency ablation (RFA) of lung VX2 tumor implanted in rabbits. Thirteen rabbits with successfully implanted lung VX2 were used. Three rabbits as controls did not receive RFA while the other ten rabbits underwent RFA; 5 complete and 5 partial. RFA was performed using an internally cooled, 17-gauge electrode (Radionics, Burlington, MA) with a 1-cm active tip under CT guidance. Postprocedural CT was performed within 3 days, and we analyzed the ablated size, enhancement pattern, shape, margin, and complications of the complete and partial ablation groups. Rabbits were sacrificed after postprocedural CT with an overdose of ketamine, and pathologic findings of the ablated groups were compared with those of the control group. The size of the ablated lesions and the enhancement pattern differed between the completely and partially ablated groups on chest CT. The size of the ablated lesions was increased by 47.1% in the completely ablated group and by 2.1% in the partially ablated group. In the completely ablated group, VX2 tumor showed absolutely no enhancement, whereas only ablated pulmonary parenchyma outside VX2 showed mild enhancement on enhanced CT. In the partial ablated group, a part of VX2 became strongly enhanced on enhanced CT. On microscopic examination, the completely ablated group demonstrated that a viable tumor cell was not visible. In the partially ablated group, however, a viable tumor cell within the surrounding fibrous capsule on the peripheral area of the VX2 was observed. The important CT findings for evaluation of complete and partial RFA are the ablated size and enhancement pattern of the ablated lesion.
Predicting Social Anxiety Treatment Outcome Based on Therapeutic Email Conversations.
Hoogendoorn, Mark; Berger, Thomas; Schulz, Ava; Stolz, Timo; Szolovits, Peter
2017-09-01
Predicting therapeutic outcome in the mental health domain is of utmost importance to enable therapists to provide the most effective treatment to a patient. Using information from the writings of a patient can potentially be a valuable source of information, especially now that more and more treatments involve computer-based exercises or electronic conversations between patient and therapist. In this paper, we study predictive modeling using writings of patients under treatment for a social anxiety disorder. We extract a wealth of information from the text written by patients including their usage of words, the topics they talk about, the sentiment of the messages, and the style of writing. In addition, we study trends over time with respect to those measures. We then apply machine learning algorithms to generate the predictive models. Based on a dataset of 69 patients, we are able to show that we can predict therapy outcome with an area under the curve of 0.83 halfway through the therapy and with a precision of 0.78 when using the full data (i.e., the entire treatment period). Due to the limited number of participants, it is hard to generalize the results, but they do show great potential in this type of information.
Machine learning for outcome prediction of acute ischemic stroke post intra-arterial therapy.
Directory of Open Access Journals (Sweden)
Hamed Asadi
Full Text Available INTRODUCTION: Stroke is a major cause of death and disability. Accurately predicting stroke outcome from a set of predictive variables may identify high-risk patients and guide treatment approaches, leading to decreased morbidity. Logistic regression models allow for the identification and validation of predictive variables. However, advanced machine learning algorithms offer an alternative, in particular, for large-scale multi-institutional data, with the advantage of easily incorporating newly available data to improve prediction performance. Our aim was to design and compare different machine learning methods, capable of predicting the outcome of endovascular intervention in acute anterior circulation ischaemic stroke. METHOD: We conducted a retrospective study of a prospectively collected database of acute ischaemic stroke treated by endovascular intervention. Using SPSS®, MATLAB®, and Rapidminer®, classical statistics as well as artificial neural network and support vector algorithms were applied to design a supervised machine capable of classifying these predictors into potential good and poor outcomes. These algorithms were trained, validated and tested using randomly divided data. RESULTS: We included 107 consecutive acute anterior circulation ischaemic stroke patients treated by endovascular technique. Sixty-six were male and the mean age of 65.3. All the available demographic, procedural and clinical factors were included into the models. The final confusion matrix of the neural network, demonstrated an overall congruency of ∼ 80% between the target and output classes, with favourable receiving operative characteristics. However, after optimisation, the support vector machine had a relatively better performance, with a root mean squared error of 2.064 (SD: ± 0.408. DISCUSSION: We showed promising accuracy of outcome prediction, using supervised machine learning algorithms, with potential for incorporation of larger multicenter
Post-injury personality in the prediction of outcome following severe acquired brain injury.
Cattran, Charlotte Jane; Oddy, Michael; Wood, Rodger Llewellyn; Moir, Jane Frances
2011-01-01
The aim of the study was to examine the utility of five measures of non-cognitive neurobehavioural (NCNB) changes that often occur following acquired brain injury, in predicting outcome (measured in terms of participation and social adaptation) at 1-year follow-up. The study employed a longitudinal, correlational design. Multiple regression was employed to investigate the value of five new NCNB measures of social perception, emotional regulation, motivation, impulsivity and disinhibition in the prediction of outcome as measured by the Mayo-Portland Adaptability Inventory (MPAI). Two NCNB measures (motivation and emotional regulation) were found to significantly predict outcome at 1-year follow-up, accounting for 53% of the variance in MPAI total scores. These measures provide a method of quantifying the extent of NCNB changes following brain injury. The predictive value of the measures indicates that they may represent a useful tool which could aid clinicians in identifying early-on those whose symptoms are likely to persist and who may require ongoing intervention. This could facilitate the planning of rehabilitation programmes.
Pediatric extracorporeal shock wave lithotripsy: Predicting successful outcomes.
McAdams, Sean; Shukla, Aseem R
2010-10-01
Extracorporeal shock wave lithotripsy (ESWL) is currently a first-line procedure of most upper urinary tract stones ionizing radiation, perhaps utilizing advancements in ultrasound and magnetic resonance imaging. This report provides a review of the current literature evaluating the patient attributes and stone factors that may be predictive of successful ESWL outcomes along with reviewing the role of pre-operative imaging and considerations for patient safety.
McGirt, Matthew J; Bydon, Mohamad; Archer, Kristin R; Devin, Clinton J; Chotai, Silky; Parker, Scott L; Nian, Hui; Harrell, Frank E; Speroff, Theodore; Dittus, Robert S; Philips, Sharon E; Shaffrey, Christopher I; Foley, Kevin T; Asher, Anthony L
2017-10-01
OBJECTIVE Quality and outcomes registry platforms lie at the center of many emerging evidence-driven reform models. Specifically, clinical registry data are progressively informing health care decision-making. In this analysis, the authors used data from a national prospective outcomes registry (the Quality Outcomes Database) to develop a predictive model for 12-month postoperative pain, disability, and quality of life (QOL) in patients undergoing elective lumbar spine surgery. METHODS Included in this analysis were 7618 patients who had completed 12 months of follow-up. The authors prospectively assessed baseline and 12-month patient-reported outcomes (PROs) via telephone interviews. The PROs assessed were those ascertained using the Oswestry Disability Index (ODI), EQ-5D, and numeric rating scale (NRS) for back pain (BP) and leg pain (LP). Variables analyzed for the predictive model included age, gender, body mass index, race, education level, history of prior surgery, smoking status, comorbid conditions, American Society of Anesthesiologists (ASA) score, symptom duration, indication for surgery, number of levels surgically treated, history of fusion surgery, surgical approach, receipt of workers' compensation, liability insurance, insurance status, and ambulatory ability. To create a predictive model, each 12-month PRO was treated as an ordinal dependent variable and a separate proportional-odds ordinal logistic regression model was fitted for each PRO. RESULTS There was a significant improvement in all PROs (p disability, QOL, and pain outcomes following lumbar spine surgery were employment status, baseline NRS-BP scores, psychological distress, baseline ODI scores, level of education, workers' compensation status, symptom duration, race, baseline NRS-LP scores, ASA score, age, predominant symptom, smoking status, and insurance status. The prediction discrimination of the 4 separate novel predictive models was good, with a c-index of 0.69 for ODI, 0.69 for EQ-5
Hard tissue ablation with a spray-assisted mid-IR laser
International Nuclear Information System (INIS)
Kang, H W; Rizoiu, I; Welch, A J
2007-01-01
The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment
Hard tissue ablation with a spray-assisted mid-IR laser
Kang, H. W.; Rizoiu, I.; Welch, A. J.
2007-12-01
The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment.
Satisfaction of psychotic patients with care and its value to predict outcomes
Vermeulen, J. M.; Schirmbeck, N. F.; Van Tricht, M. J.; de Haan, L.
2018-01-01
Background: A key indicator of quality of treatment from the patient's perspective is expressed by satisfaction with care. Our aim was to (i) explore satisfaction and its relation to clinical outcome measures; and (ii) explore the predictive value of satisfaction for the course of outcomes over
Fractional ablative laser skin resurfacing: a review.
Tajirian, Ani L; Tarijian, Ani L; Goldberg, David J
2011-12-01
Ablative laser technology has been in use for many years now. The large side effect profile however has limited its use. Fractional ablative technology is a newer development which combines a lesser side effect profile along with similar efficacy. In this paper we review fractional ablative laser skin resurfacing.
LENUS (Irish Health Repository)
Hayes, Christopher Ruslan
2012-02-01
INTRODUCTION: A recent single-center report indicated that the performance of atrial fibrillation ablation in patients on uninterrupted warfarin using a conventional deflectable tip electrode ablation catheter may be as safe as periprocedural discontinuation of warfarin and bridging with heparin. Novel multi-electrode array catheters for atrial fibrillation ablation are currently undergoing clinical evaluation. While offering the possibility of more rapid atrial fibrillation ablation, they are stiffer and necessitate the deployment of larger deflectable transseptal sheaths, and it remains to be determined if they increase the risk of cardiac perforation and vascular injury. Such potential risks would have implications for a strategy of uninterrupted periprocedural anticoagulation. METHOD AND RESULTS: We audited the safety outcomes of our atrial fibrillation ablation procedures using multi-electrode array ablation catheters in patients on uninterrupted warfarin (CHADS2 score>or=2) and in patients not on warfarin (uninterrupted aspirin). Two bleeding complications occurred in 49 patients on uninterrupted warfarin, both of which were managed successfully without longterm sequelae, and no bleeding complication occurred in 32 patients not on warfarin (uninterrupted aspirin). There were no thromboembolic events or other complication with either anticoagulant regimen. CONCLUSION: Despite the larger diameter and increased stiffness of multi-electrode array catheters and their deflectable transseptal sheaths, their use for catheter ablation in patients with atrial fibrillation on uninterrupted warfarin in this single-center experience does not appear to be unsafe, and thus, an adequately powered multicenter prospective randomized controlled trial should be considered.
A new nomogram to predict pathologic outcome following radical prostatectomy
Directory of Open Access Journals (Sweden)
Alexandre Crippa
2006-04-01
Full Text Available OBJECTIVE: To develop a preoperative nomogram to predict pathologic outcome in patients submitted to radical prostatectomy for clinical localized prostate cancer. MATERIALS AND METHODS: Nine hundred and sixty patients with clinical stage T1 and T2 prostate cancer were evaluated following radical prostatectomy, and 898 were included in the study. Following a multivariate analysis, nomograms were developed incorporating serum PSA, biopsy Gleason score, and percentage of positive biopsy cores in order to predict the risks of extraprostatic tumor extension, and seminal vesicle involvement. RESULTS: In univariate analysis there was a significant association between percentage of positive biopsy cores (p < 0.001, serum PSA (p = 0.001 and biopsy Gleason score (p < 0.001 with extraprostatic tumor extension. A similar pathologic outcome was seen among tumors with Gleason score 7, and Gleason score 8 to 10. In multivariate analysis, the 3 preoperative variables showed independent significance to predict tumor extension. This allowed the development of nomogram-1 (using Gleason scores in 3 categories - 2 to 6, 7 and 8 to 10 and nomogram-2 (using Gleason scores in 2 categories - 2 to 6 and 7 to 10 to predict disease extension based on these 3 parameters. In the validation analysis, 87% and 91.1% of the time the nomograms-1 and 2, correctly predicted the probability of a pathological stage to within 10% respectively. CONCLUSION: Incorporating percent of positive biopsy cores to a nomogram that includes preoperative serum PSA and biopsy Gleason score, can accurately predict the presence of extraprostatic disease extension in patients with clinical localized prostate cancer.
Chemically assisted laser ablation ICP mass spectrometry.
Hirata, Takafumi
2003-01-15
A new laser ablation technique combined with a chemical evaporation reaction has been developed for elemental ratio analysis of solid samples using an inductively coupled plasma mass spectrometer (ICPMS). Using a chemically assisted laser ablation (CIA) technique developed in this study, analytical repeatability of the elemental ratio measurement was successively improved. To evaluate the reliability of the CLA-ICPMS technique, Pb/U isotopic ratios were determined for zircon samples that have previously been analyzed by other techniques. Conventional laser ablation for Pb/U shows a serious elemental fractionation during ablation mainly due to the large difference in elemental volatility between Pb and U. In the case of Pb/U ratio measurement, a Freon R-134a gas (1,1,1,2-tetrafluoroethane) was introduced into the laser cell as a fluorination reactant. The Freon gas introduced into the laser cell reacts with the ablated sample U, and refractory U compounds are converted to a volatile U fluoride compound (UF6) under the high-temperature condition at the ablation site. This avoids the redeposition of U around the ablation pits. Although not all the U is reacted with Freon, formation of volatile UF compounds improves the transmission efficiency of U. Typical precision of the 206Pb/238U ratio measurement is 3-5% (2sigma) for NIST SRM 610 and Nancy 91500 zircon standard, and the U-Pb age data obtained here show good agreement within analytical uncertainties with the previously reported values. Since the observed Pb/U ratio for solid samples is relatively insensitive to laser power and ablation time, optimization of ablation conditions or acquisition parameters no longer needs to be performed on a sample-to-sample basis.
Predicting Outcome in Patients with Anti-GBM Glomerulonephritis.
van Daalen, Emma E; Jennette, J Charles; McAdoo, Stephen P; Pusey, Charles D; Alba, Marco A; Poulton, Caroline J; Wolterbeek, Ron; Nguyen, Tri Q; Goldschmeding, Roel; Alchi, Bassam; Griffiths, Meryl; de Zoysa, Janak R; Vincent, Beula; Bruijn, Jan A; Bajema, Ingeborg M
2018-01-06
Large studies on long-term kidney outcome in patients with anti-glomerular basement membrane (anti-GBM) GN are lacking. This study aimed to identify clinical and histopathologic parameters that predict kidney outcome in these patients. This retrospective analysis included a total of 123 patients with anti-GBM GN between 1986 and 2015 from six centers worldwide. Their kidney biopsy samples were classified according to the histopathologic classification for ANCA-associated GN. Clinical data such as details of treatment were retrieved from clinical records. The primary outcome parameter was the occurrence of ESRD. Kidney survival was analyzed using the log-rank test and Cox regression analyses. The 5-year kidney survival rate was 34%, with an improved rate observed among patients diagnosed after 2007 ( P =0.01). In patients with anti-GBM GN, histopathologic class and kidney survival were associated ( P GBM GN. Kidney outcome has improved during recent years; the success rate doubled after 2007. This article contains a podcast at https://www.asn-online.org/media/podcast/CJASN/2017_11_21_CJASNPodcast_18_1_v.mp3. Copyright © 2018 by the American Society of Nephrology.
Preoperative prediction model of outcome after cholecystectomy for symptomatic gallstones
DEFF Research Database (Denmark)
Borly, L; Anderson, I B; Bardram, L
1999-01-01
and sonography evaluated gallbladder motility, gallstones, and gallbladder volume. Preoperative variables in patients with or without postcholecystectomy pain were compared statistically, and significant variables were combined in a logistic regression model to predict the postoperative outcome. RESULTS: Eighty...... and by the absence of 'agonizing' pain and of symptoms coinciding with pain (P model 15 of 18 predicted patients had postoperative pain (PVpos = 0.83). Of 62 patients predicted as having no pain postoperatively, 56 were pain-free (PVneg = 0.90). Overall accuracy...... was 89%. CONCLUSION: From this prospective study a model based on preoperative symptoms was developed to predict postcholecystectomy pain. Since intrastudy reclassification may give too optimistic results, the model should be validated in future studies....
Relative size predicts competitive outcome through 2 million years.
Liow, Lee Hsiang; Di Martino, Emanuela; Krzeminska, Malgorzata; Ramsfjell, Mali; Rust, Seabourne; Taylor, Paul D; Voje, Kjetil L
2017-08-01
Competition is an important biotic interaction that influences survival and reproduction. While competition on ecological timescales has received great attention, little is known about competition on evolutionary timescales. Do competitive abilities change over hundreds of thousands to millions of years? Can we predict competitive outcomes using phenotypic traits? How much do traits that confer competitive advantage and competitive outcomes change? Here we show, using communities of encrusting marine bryozoans spanning more than 2 million years, that size is a significant determinant of overgrowth outcomes: colonies with larger zooids tend to overgrow colonies with smaller zooids. We also detected temporally coordinated changes in average zooid sizes, suggesting that different species responded to a common external driver. Although species-specific average zooid sizes change over evolutionary timescales, species-specific competitive abilities seem relatively stable, suggesting that traits other than zooid size also control overgrowth outcomes and/or that evolutionary constraints are involved. © 2017 John Wiley & Sons Ltd/CNRS.
Newton-Howes, Giles; Mulder, Roger; Ellis, Pete M; Boden, Joseph M; Joyce, Peter
2017-09-19
There is debate around the best model for diagnosing personality disorder, both in terms of its relationship to the empirical data and clinical utility. Four randomized controlled trials examining various treatments for depression were analyzed at an individual patient level. Three different approaches to the diagnosis of personality disorder were analyzed in these patients. A total of 578 depressed patients were included in the analysis. Personality disorder, however measured, was of little predictive utility in the short term but added significantly to predictive modelling of medium-term outcomes, accounting for more than twice as much of the variance in social functioning outcome as depression psychopathology. Personality disorder assessment is of predictive utility with longer timeframes and when considering social outcomes as opposed to symptom counts. This utility is sufficiently great that there appears to be value in assessing personality; however, no particular approach outperforms any other.
Image-guided radiofrequency ablation (RFA) of spinal tumors
International Nuclear Information System (INIS)
Gevargez, Athour; Groenemeyer, Dietrich H.W.
2008-01-01
Purpose: To evaluate retrospectively the efficacy and safety of radiofrequency ablation (RFA) in patients with spinal tumors. Materials and methods: Forty-one patients (25 men, 16 women; age range, 46-82 years) with nonresectable primary or secondary tumor involvement of the spine unresponsive to chemo- and radiotherapy received RFA treatment. Two radiofrequency ablation systems, one with a cool-tip electrode and one with an expandable electrode catheter, were used. Both systems work impedance controlled with a power output of 150- 200 W. Each coagulation cycle lasted 12-15 min depending on tumor impedance. Several single RFA cycles of 15 min each were used for overlapping RFAs in tumors with diameters of more than 3 cm. Temperature was kept between 50 deg. C and 120 deg. C and was chosen according to spinal cord distance and patient heat tolerance during the ablation. Multi-slice computed tomography (CT) combined with C-arm fluoroscopy guided the intervention. Efficacy outcomes were assessed after about 6 weeks, 6 months, and more than 6 months using standardized questionnaires and indices regarding tumor pain, pain disability, functional activities, quality of life, neurological status, and tumor progression. Results: RFA significantly reduced tumor-induced pain within 6 weeks, improved daily activities, and maintained quality of life. Mean time to tumor progression was 730 ± 54 days (Kaplan-Meier estimate). No RFA-associated complications were reported. Conclusion: RFA of primary and secondary spinal tumors, which were unresponsive to chemo- and radiotherapy and prone to progression, is a safe, resource-saving, and highly effective percutaneous technique in patients with nonresectable spinal tumors
Simulation of radiofrequency ablation in real human anatomy.
Zorbas, George; Samaras, Theodoros
2014-12-01
The objective of the current work was to simulate radiofrequency ablation treatment in computational models with realistic human anatomy, in order to investigate the effect of realistic geometry in the treatment outcome. The body sites considered in the study were liver, lung and kidney. One numerical model for each body site was obtained from Duke, member of the IT'IS Virtual Family. A spherical tumour was embedded in each model and a single electrode was inserted into the tumour. The same excitation voltage was used in all cases to underline the differences in the resulting temperature rise, due to different anatomy at each body site investigated. The same numerical calculations were performed for a two-compartment model of the tissue geometry, as well as with the use of an analytical approximation for a single tissue compartment. Radiofrequency ablation (RFA) therapy appears efficient for tumours in liver and lung, but less efficient in kidney. Moreover, the time evolution of temperature for a realistic geometry differs from that for a two-compartment model, but even more for an infinite homogenous tissue model. However, it appears that the most critical parameters of computational models for RFA treatment planning are tissue properties rather than tissue geometry. Computational simulations of realistic anatomy models show that the conventional technique of a single electrode inside the tumour volume requires a careful choice of both the excitation voltage and treatment time in order to achieve effective treatment, since the ablation zone differs considerably for various body sites.
International Nuclear Information System (INIS)
Veltri, Andrea; Sacchetto, Paola; Tosetti, Irene; Pagano, Eva; Fava, Cesare; Gandini, Giovanni
2008-01-01
The objective of this study was to analyze long-term results of radiofrequency thermal ablation (RFA) for colorectal metastases (MTS), in order to evaluate predictors for adverse events, technique effectiveness, and survival. One hundred ninety-nine nonresectable MTS (0.5-8 cm; mean, 2.9 cm) in 122 patients underwent a total of 166 RFA sessions, percutaneously or during surgery. The technique was 'simple' or 'combined' with vascular occlusion. The mean follow-up time was 24.2 months. Complications, technique effectiveness, and survival rates were statistically analyzed. Adverse events occurred in 8.1% of lesions (major complication rate: 1.1%), 7.1% with simple and 16.7% with combined technique (p = 0.15). Early complete response was obtained in 151 lesions (81.2%), but 49 lesions (26.3%) recurred locally after a mean of 10.4 months. Sustained complete ablation was achieved in 66.7% of lesions ≤3 cm versus 33.3% of lesions >3 cm (p 3 cm (p = 0.006). We conclude that 'simple' RFA is safe and successful for MTS ≤3 cm, contributing to prolong survival when patients can be completely treated.
Endometrial Receptivity and its Predictive Value for IVF/ICSI-Outcome.
Heger, A; Sator, M; Pietrowski, D
2012-08-01
Endometrial receptivity plays a crucial role in the establishment of a healthy pregnancy in cycles of assisted reproduction. The endometrium as a key factor during reproduction can be assessed in multiple ways, most commonly through transvaginal grey-scale or 3-D ultrasound. It has been shown that controlled ovarian hyperstimulation has a great impact on the uterine lining, which leads to different study results for the predictive value of endometrial factors measured on different cycle days. There is no clear consensus on whether endometrial factors are appropriate to predict treatment outcome and if so, which one is suited best. The aim of this review is to summarize recent findings of studies about the influence of endometrial thickness, volume and pattern on IVF- and ICSI-treatment outcome and provide an overview of future developments in the field.
Steinert, Christiane; Klein, Susanne; Leweke, Frank; Leichsenring, Falk
2015-03-01
Whether personality characteristics have an impact on treatment outcome is an important question in psychotherapy research. One of the most common approaches for the description of personality is the five-factor model of personality. Only few studies investigated whether patient personality as measured with the NEO-Five-Factor Inventory (NEO-FFI, Costa & McCrae [1992b]. Revised NEO-PI-R and NEO-FFI. Professional manual. Odessa, FL: Psychological Assessment Recources) predicts outcome. Results were inconsistent. Studies reporting personality to be predictive of outcome did not control for baseline symptoms, while studies controlling initial symptoms could not support these findings. We hypothesized that after taking into account baseline symptoms, the NEO-FFI would not predict outcome and tested this in a large sample of inpatients at a psychosomatic clinic. Naturalistic, non-controlled study using patients' data for multiple regression analysis to identify predictors of outcome. Data of 254 inpatients suffering primarily from depressive, anxiety, stress, and somatoform disorders were analysed. Personality was assessed at the beginning of therapy. For psychotherapy outcome, changes in anxiety and depression (Hospital Anxiety and Depression Scale; HADS), overall psychopathology (Symptom Checklist-90-R Global Severity Index [GSI]), and interpersonal problems (Inventory of Interpersonal Problems; IIP) were measured. The treatment resulted in significant decreases on all outcome measures corresponding to moderate to large effect sizes (HADS: d = 1.03; GSI: d = 0.90; IIP: d = 0.38). Consistent with our hypothesis, none of the personality domains predicted outcome when baseline symptoms were controlled for. Personality assessment at baseline does not seem to have an added value in the prediction of inpatient psychotherapy outcome beyond initial symptoms. Clinical implications Personality dimensions overlap with symptomatic distress. Rather than serve as predictors of
FDG PET imaging for grading and prediction of outcome in chondrosarcoma patients
Energy Technology Data Exchange (ETDEWEB)
Brenner, Winfried; Eary, Janet F. [Division of Nuclear Medicine, University of Washington Medical Center, 1959 NE Pacific Street, Box 356113, WA 98195-6113, Seattle (United States); Conrad, Ernest U. [Department of Orthopaedics, University of Washington Medical Center, Seattle, WA (United States)
2004-02-01
The aims of this study were to assess the potential of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) for tumor grading in chondrosarcoma patients and to evaluate the role of standardized uptake value (SUV) as a parameter for prediction of patient outcome. FDG PET imaging was performed in 31 patients with chondrosarcoma prior to therapy. SUV was calculated for each tumor and correlated to tumor grade and size, and to patient outcome in terms of local relapse or metastatic disease with a mean follow-up period of 48 months. Chondrosarcomas were detectable in all patients. Tumor SUV was 3.38{+-}1.61 for grade I (n=15), 5.44{+-}3.06 for grade II (n=13), and 7.10{+-}2.61 for grade III (n=3). Significant differences were found between patients with and without disease progression: SUV was 6.42{+-}2.70 (n=10) in patients developing recurrent or metastatic disease compared with 3.74{+-}2.22 in patients without relapse (P=0.015). Using a cut-off of 4 for SUV, sensitivity, specificity, and positive and negative predictive values for a relapse were 90%, 76%, 64%, and 94%, respectively. Combining tumor grade and SUV, these parameters improved to 90%, 95%, 90%, and 95%, respectively. Pretherapeutic tumor SUV obtained by FDG PET imaging was a useful parameter for tumor grading and prediction of outcome in chondrosarcoma patients. The combination of SUV and histopathologic tumor grade further improved prediction of outcome substantially, allowing identification of patients at high risk for local relapse or metastatic disease. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Rosset, Remy; Bratan, Flavie [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Crouzet, Sebastien [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Universite de Lyon, Lyon (France); Faculte de Medecine Lyon Est, Universite Lyon 1, Lyon (France); Inserm, U1032, LabTau, Lyon (France); Tonoli-Catez, Helene [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Mege-Lechevallier, Florence [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Pathology, Lyon (France); Gelet, Albert [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Inserm, U1032, LabTau, Lyon (France); Rouviere, Olivier [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Universite de Lyon, Lyon (France); Faculte de Medecine Lyon Est, Universite Lyon 1, Lyon (France); Inserm, U1032, LabTau, Lyon (France)
2017-04-15
Our aim was to assess whether magnetic resonance imaging (MRI) features predict recurrence-free survival (RFS) after prostate cancer high-intensity focused ultrasound (HIFU) ablation. We retrospectively selected 81 patients who underwent (i) whole-gland HIFU ablation between 2007 and 2011 as first-line therapy or salvage treatment after radiotherapy or brachytherapy, and (ii) pre- and postoperative MRI. On preoperative imaging, two senior (R1, R2) and one junior (R3) readers assessed the number of sectors invaded by the lesion with the highest Likert score (dominant lesion) using a 27-sector diagram. On postoperative imaging, readers assessed destruction of the dominant lesion using a three-level score. Multivariate analysis included the number of sectors invaded by the dominant lesion, its Likert and destruction scores, the pre-HIFU prostate-specific antigen (PSA) level, Gleason score, and the clinical setting (primary/salvage). The most significant predictor was the number of prostate sectors invaded by the dominant lesion for R2 and R3 (p≤0.001) and the destruction score of the dominant lesion for R1 (p = 0.011). The pre-HIFU PSA level was an independent predictor for R2 (p = 0.014), but with only marginal significance for R1 (p = 0.059) and R3 (p = 0.053). The dominant lesion's size and destruction assessed by MRI provide independent prognostic information compared with usual predictors. (orig.)
Automated planning of ablation targets in atrial fibrillation treatment
Keustermans, Johannes; De Buck, Stijn; Heidbüchel, Hein; Suetens, Paul
2011-03-01
Catheter based radio-frequency ablation is used as an invasive treatment of atrial fibrillation. This procedure is often guided by the use of 3D anatomical models obtained from CT, MRI or rotational angiography. During the intervention the operator accurately guides the catheter to prespecified target ablation lines. The planning stage, however, can be time consuming and operator dependent which is suboptimal both from a cost and health perspective. Therefore, we present a novel statistical model-based algorithm for locating ablation targets from 3D rotational angiography images. Based on a training data set of 20 patients, consisting of 3D rotational angiography images with 30 manually indicated ablation points, a statistical local appearance and shape model is built. The local appearance model is based on local image descriptors to capture the intensity patterns around each ablation point. The local shape model is constructed by embedding the ablation points in an undirected graph and imposing that each ablation point only interacts with its neighbors. Identifying the ablation points on a new 3D rotational angiography image is performed by proposing a set of possible candidate locations for each ablation point, as such, converting the problem into a labeling problem. The algorithm is validated using a leave-one-out-approach on the training data set, by computing the distance between the ablation lines obtained by the algorithm and the manually identified ablation points. The distance error is equal to 3.8+/-2.9 mm. As ablation lesion size is around 5-7 mm, automated planning of ablation targets by the presented approach is sufficiently accurate.
Energy Technology Data Exchange (ETDEWEB)
Men, Min; Ye, Xin; Yang, Xia; Zheng, Aimin; Huang, Guang Hui; Wei, Zhigang [Dept. of Oncology, Shandong Provincial Hospital Affiliated with Shandong University, Jinan (China); Fan, Wei Jun [Imaging and Interventional Center, Sun Yat-sen University Cancer Center, Guangzhou (China); Zhang, Kaixian [Dept. of Oncology, Teng Zhou Central People' s Hospital Affiliated with Jining Medical College, Tengzhou (China); Bi, Jing Wang [Dept. of Oncology, Jinan Military General Hospital of Chinese People' s Liberation Army, Jinan (China)
2016-11-15
To retrospectively evaluate the short-term outcomes and safety of computed tomography (CT)-guided percutaneous microwave ablation (MWA) of solitary adrenal metastasis from lung cancer. From May 2010 to April 2014, 31 patients with unilateral adrenal metastasis from lung cancer who were treated with CT-guided percutaneous MWA were enrolled. This study was conducted with approval from local Institutional Review Board. Clinical outcomes and complications of MWA were assessed. Their tumors ranged from 1.5 to 5.4 cm in diameter. After a median follow-up period of 11.1 months, primary efficacy rate was 90.3% (28/31). Local tumor progression was detected in 7 (22.6%) of 31 cases. Their median overall survival time was 12 months. The 1-year overall survival rate was 44.3%. Median local tumor progression-free survival time was 9 months. Local tumor progression-free survival rate was 77.4%. Of 36 MWA sessions, two (5.6%) had major complications (hypertensive crisis). CT-guided percutaneous MWA may be fairly safe and effective for treating solitary adrenal metastasis from lung cancer.
Lee, Sang Hoon; Kim, Seung Up; Jang, Jeong Won; Bae, Si Hyun; Lee, Sanghun; Kim, Beom Kyung; Park, Jun Yong; Kim, Do Young; Ahn, Sang Hoon; Han, Kwang-Hyub
2015-01-01
Liver stiffness (LS) measurement using transient elastography can accurately assess the degree of liver fibrosis, which is associated with the risk of the development of hepatocellular carcinoma (HCC). We investigated whether LS values could predict HCC de novo recurrence after radiofrequency ablation (RFA). This retrospective, multicenter study analyzed 111 patients with HCC who underwent RFA and LS measurement using transient elastography between May 2005 and April 2011. All patients were followed until March 2013 to monitor for HCC recurrence. This study included 76 men and 35 women with a mean age of 62.4 years, and the mean LS value was 21.2 kPa. During the follow-up period (median 22.4 months), 47 (42.3%) patients experienced HCC de novo recurrence, and 18 (16.2%) died. Patients with recurrence had significantly more frequent liver cirrhosis, more frequent history of previous treatment for HCC, higher total bilirubin, larger spleen size, larger total tumor size, higher tumor number, higher LS values, and lower platelet counts than those without recurrence (all P13.0 kPa were at significantly greater risk for recurrence after RFA, with a hazard ratio (HR) of 3.115 (95% confidence interval [CI], 1.238-7.842, Pmeasurement is a useful predictor of HCC de novo recurrence and overall survival after RFA.
Cerebrospinal fluid neurofilament light chain levels predict visual outcome after optic neuritis
DEFF Research Database (Denmark)
Modvig, Signe; Degn, M; Sander, B
2016-01-01
BACKGROUND: Optic neuritis is a good model for multiple sclerosis relapse, but currently no tests can accurately predict visual outcome. OBJECTIVE: The purpose of this study was to examine whether cerebrospinal fluid (CSF) biomarkers of tissue damage and remodelling (neurofilament light chain (NF......-L, β=-1.1, p=0.0150 for GC-IPL). Complete/incomplete remission was determined based on LCVA from 30 healthy controls. NF-L had a positive predictive value of 91% and an area under the curve (AUC) of 0.79 for incomplete remission. CONCLUSION: CSF NF-L is a promising biomarker of visual outcome after...
DEFF Research Database (Denmark)
Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen
2015-01-01
BACKGROUND: Catheter ablation with remote magnetic navigation (RMN) can offer some advantages compared to manual techniques. However, the relevant clinical evidence for how RMN-guided ablation affects electrical storm (ES) due to ventricular tachycardia (VT) in patients with severe ischemic heart......-guided catheter ablation can prevent VT recurrence and significantly reduce ICD shocks, suggesting that this strategy can be used as an alternative therapy for VT storm in SIHF patients with ICDs....
Geng, Xiaonan; Li, Qiang; Tsui, Pohsiang; Wang, Chiaoyin; Liu, Haoli
2013-09-01
To evaluate the reliability of diagnostic ultrasound-based temperature and elasticity imaging during radiofrequency ablation (RFA) through ex vivo experiments. Procine liver samples (n=7) were employed for RFA experiments with exposures of different power intensities (10 and 50w). The RFA process was monitored by a diagnostic ultrasound imager and the information were postoperatively captured for further temperature and elasticity image analysis. Infrared thermometry was concurrently applied to provide temperature change calibration during the RFA process. Results from this study demonstrated that temperature imaging was valid under 10 W RF exposure (r=0.95), but the ablation zone was no longer consistent with the reference infrared temperature distribution under high RF exposures. The elasticity change could well reflect the ablation zone under a 50 W exposure, whereas under low exposures, the thermal lesion could not be well detected due to the limited range of temperature elevation and incomplete tissue necrosis. Diagnostic ultrasound-based temperature and elastography is valid for monitoring thr RFA process. Temperature estimation can well reflect mild-power RF ablation dynamics, whereas the elastic-change estimation can can well predict the tissue necrosis. This study provide advances toward using diagnostic ultrasound to monitor RFA or other thermal-based interventions.
Revised neutral gas shielding model for pellet ablation - combined neutral and plasma shielding
International Nuclear Information System (INIS)
Houlberg, W.A.; Schuresko, D.D.; Attenberger, S.E.
1986-01-01
The ablation and penetration of pellets in early ORMAK and ISX-A experiments were reliably predicted by the neutral gas shielding model of Milora and Foster. These experiments demonstrated that the principle components of the model - a self-generated shield which reduces the heat flux at the plasma surface - were correct. In more recent experiments with higher temperature plasmas, this model consistently predicts greater penetration than observed in the experiments. Upgarding known limitations of the original model brings the predicted and observed penetration values into agreement. These improvements include: (1) treating the incident electrons as having distribution in energy rather than being monoenergetic; (2) including the shielding effects of cold, dense plasma extending along the magnetic field outside the neutral shield; and (3) modifying the finite plasma, self-limiting incident heat flux so that it represents a collisionless plasma limit rather than a collisional limit. Comparisons are made between the models for a selection of ISX-B Alcator-C, and TFTR shots. The net effect of the changes in the model is an increase in pellet ablation rates and decrease in penetration for current and future experiments
Femtosecond laser ablation of dentin
International Nuclear Information System (INIS)
Alves, S; Vilar, R; Oliveira, V
2012-01-01
The surface morphology, structure and composition of human dentin treated with a femtosecond infrared laser (pulse duration 500 fs, wavelength 1030 nm, fluences ranging from 1 to 3 J cm -2 ) was studied by scanning electron microscopy, x-ray diffraction, x-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The average dentin ablation threshold under these conditions was 0.6 ± 0.2 J cm -2 and the ablation rate achieved in the range 1 to 2 µm/pulse for an average fluence of 3 J cm -2 . The ablation surfaces present an irregular and rugged appearance, with no significant traces of melting, deformation, cracking or carbonization. The smear layer was entirely removed by the laser treatment. For fluences only slightly higher than the ablation threshold the morphology of the laser-treated surfaces was very similar to the dentin fracture surfaces and the dentinal tubules remained open. For higher fluences, the surface was more porous and the dentin structure was partially concealed by ablation debris and a few resolidified droplets. Independently on the laser processing parameters and laser processing method used no sub-superficial cracking was observed. The dentin constitution and chemical composition was not significantly modified by the laser treatment in the processing parameter range used. In particular, the organic matter is not preferentially removed from the surface and no traces of high temperature phosphates, such as the β-tricalcium phosphate, were observed. The achieved results are compatible with an electrostatic ablation mechanism. In conclusion, the high beam quality and short pulse duration of the ultrafast laser used should allow the accurate preparation of cavities, with negligible damage of the underlying material. (paper)
Hung, Andrew J; Chen, Jian; Che, Zhengping; Nilanon, Tanachat; Jarc, Anthony; Titus, Micha; Oh, Paul J; Gill, Inderbir S; Liu, Yan
2018-05-01
Surgical performance is critical for clinical outcomes. We present a novel machine learning (ML) method of processing automated performance metrics (APMs) to evaluate surgical performance and predict clinical outcomes after robot-assisted radical prostatectomy (RARP). We trained three ML algorithms utilizing APMs directly from robot system data (training material) and hospital length of stay (LOS; training label) (≤2 days and >2 days) from 78 RARP cases, and selected the algorithm with the best performance. The selected algorithm categorized the cases as "Predicted as expected LOS (pExp-LOS)" and "Predicted as extended LOS (pExt-LOS)." We compared postoperative outcomes of the two groups (Kruskal-Wallis/Fisher's exact tests). The algorithm then predicted individual clinical outcomes, which we compared with actual outcomes (Spearman's correlation/Fisher's exact tests). Finally, we identified five most relevant APMs adopted by the algorithm during predicting. The "Random Forest-50" (RF-50) algorithm had the best performance, reaching 87.2% accuracy in predicting LOS (73 cases as "pExp-LOS" and 5 cases as "pExt-LOS"). The "pExp-LOS" cases outperformed the "pExt-LOS" cases in surgery time (3.7 hours vs 4.6 hours, p = 0.007), LOS (2 days vs 4 days, p = 0.02), and Foley duration (9 days vs 14 days, p = 0.02). Patient outcomes predicted by the algorithm had significant association with the "ground truth" in surgery time (p algorithm in predicting, were largely related to camera manipulation. To our knowledge, ours is the first study to show that APMs and ML algorithms may help assess surgical RARP performance and predict clinical outcomes. With further accrual of clinical data (oncologic and functional data), this process will become increasingly relevant and valuable in surgical assessment and training.
Temperature-controlled radiofrequency ablation of cardiac tissue
DEFF Research Database (Denmark)
Petersen, H H; Chen, X; Pietersen, Adrian
1999-01-01
BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...
Laser ablation of microparticles for nanostructure generation
International Nuclear Information System (INIS)
Waraich, Palneet Singh; Tan, Bo; Venkatakrishnan, Krishnan
2011-01-01
The process of laser ablation of microparticles has been shown to generate nanoparticles from microparticles; but the generation of nanoparticle networks from microparticles has never been reported before. We report a unique approach for the generation of nanoparticle networks through ablation of microparticles. Using this approach, two samples containing microparticles of lead oxide (Pb 3 O 4 ) and nickel oxide (NiO), respectively, were ablated under ambient conditions using a femtosecond laser operating in the MHz repetition rate regime. Nanoparticle networks with particle diameter ranging from 60 to 90 nm were obtained by ablation of microparticles without use of any specialized equipment, catalysts or external stimulants. The formation of finer nanoparticle networks has been explained by considering the low pressure region created by the shockwave, causing rapid condensation of microparticles into finer nanoparticles. A comparison between the nanostructures generated by ablating microparticle and those by ablating bulk substrate was carried out; and a considerable reduction in size and narrowed size distribution was observed. Our nanostructure fabrication technique will be a unique process for nanoparticle network generation from a vast array of materials.
Peng, Chengzhong; Zhang, Zhengxian; Liu, Jibin; Chen, Hongyu; Tu, Xiao; Hu, Rihong; Ni, Jun; Weng, Ning; Pang, Haisu; Xue, Zhengmei
2017-03-01
The purpose of this study was to determine if ultrasound-guided radiofrequency ablation (RFA) of hyperplastic parathyroid glands could be used to treat secondary hyperparathyroidism (HPT) in patients with chronic kidney disease. RFA of the hyperplastic parathyroid glands was performed in 34 patients with secondary HPT. Intact parathyroid hormone (iPTH), calcium, and phosphorus were measured. The outcome was based on the ablation extent (ie, 4, 3, and 1-2 glands). The iPTH, calcium, and phosphorus levels decreased in all groups after RFA. One year after ablation, these parameters remained significantly lower in the 4-gland ablation group compared with the 3-gland and 1 to 2-gland groups. The same tendency was observed for the symptom score. The iPTH levels of secondary HPT is feasible in selected patients. © 2016 Wiley Periodicals, Inc. Head Neck 39: 564-571, 2017. © 2016 Wiley Periodicals, Inc.
Percutaneous tumor ablation in medical radiology
Energy Technology Data Exchange (ETDEWEB)
Vogl, T.J.; Mack, M.G. [University Hospital Frankfurt Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Helmberger, T.K. [Klinikum Bogenhausen, Academic Teaching Hospital of the Technical Univ. Munich (Germany). Dept. for Diagnostic and Interventional Radiology and Nuclear Medicine; Reiser, M.F. (eds.) [University Hospitals - Grosshadern and Innenstadt Munich Univ. (Germany). Dept. of Clinical Radiology
2008-07-01
Thermal ablation has become an integral part of oncology, especially in the field of interventional oncology. This very comprehensive book encompasses the different technologies employed in thermal ablation, its indications and the results achieved in various clinical conditions. The first part of the book clearly explains the basics of thermal ablative techniques such as laser-induced thermotherapy, radiofrequency ablation, microwave ablation, cryotherapy, and localized tumor therapy. The latest developments in the application of minimally invasive therapies in localized neoplastic disease are demonstrated. In the main part of the book, techniques of guiding the applicators to the target structures by use of different imaging tools such as ultrasound, computed tomography and magnetic resonance imaging are discussed. The results are presented for a variety of clinical indications, including liver and lung tumors and metastases and some rather rare conditions involving the kidney, the head and neck, the prostate, and soft tissue structures. A large number of acknowledged experts have contributed to the book, which benefits from a lucid structure and excellent images. (orig.)
Percutaneous tumor ablation in medical radiology
International Nuclear Information System (INIS)
Vogl, T.J.; Mack, M.G.; Helmberger, T.K.; Reiser, M.F.
2008-01-01
Thermal ablation has become an integral part of oncology, especially in the field of interventional oncology. This very comprehensive book encompasses the different technologies employed in thermal ablation, its indications and the results achieved in various clinical conditions. The first part of the book clearly explains the basics of thermal ablative techniques such as laser-induced thermotherapy, radiofrequency ablation, microwave ablation, cryotherapy, and localized tumor therapy. The latest developments in the application of minimally invasive therapies in localized neoplastic disease are demonstrated. In the main part of the book, techniques of guiding the applicators to the target structures by use of different imaging tools such as ultrasound, computed tomography and magnetic resonance imaging are discussed. The results are presented for a variety of clinical indications, including liver and lung tumors and metastases and some rather rare conditions involving the kidney, the head and neck, the prostate, and soft tissue structures. A large number of acknowledged experts have contributed to the book, which benefits from a lucid structure and excellent images. (orig.)
Efficacy and Safety of Ethanol Ablation for Branchial Cleft Cysts.
Ha, E J; Baek, S M; Baek, J H; Shin, S Y; Han, M; Kim, C-H
2017-12-01
Branchial cleft cyst is a common congenital lesion of the neck. This study evaluated the efficacy and safety of ethanol ablation as an alternative treatment to surgery for branchial cleft cyst. Between September 2006 and October 2016, ethanol ablation was performed in 22 patients who refused an operation for a second branchial cleft cyst. After the exclusion of 2 patients who were lost to follow-up, the data of 20 patients were retrospectively evaluated. All index masses were confirmed as benign before treatment. Sonography-guided aspiration of the cystic fluid was followed by injection of absolute ethanol (99%) into the lesion. The injected volume of ethanol was 50%-80% of the volume of fluid aspirated. Therapeutic outcome, including the volume reduction ratio, therapeutic success rate (volume reduction ratio of >50% and/or no palpable mass), and complications, was evaluated. The mean index volume of the cysts was 26.4 ± 15.7 mL (range, 3.8-49.9 mL). After ablation, the mean volume of the cysts decreased to 1.2 ± 1.1 mL (range, 0.0-3.5 mL). The mean volume reduction ratio at last follow-up was 93.9% ± 7.9% (range, 75.5%-100.0%; P branchial cleft cysts who refuse, or are ineligible for, an operation. © 2017 by American Journal of Neuroradiology.
Prediction of Functional Outcome in Axonal Guillain-Barre Syndrome.
Sung, Eun Jung; Kim, Dae Yul; Chang, Min Cheol; Ko, Eun Jae
2016-06-01
To identify the factors that could predict the functional outcome in patients with the axonal type of Guillain-Barre syndrome (GBS). Two hundred and two GBS patients admitted to our university hospital between 2003 and 2014 were reviewed retrospectively. We defined a good outcome as being "able to walk independently at 1 month after onset" and a poor outcome as being "unable to walk independently at 1 month after onset". We evaluated the factors that differed between the good and poor outcome groups. Twenty-four patients were classified into the acute motor axonal neuropathy type. There was a statistically significant difference between the good and poor outcome groups in terms of the GBS disability score at admission, and GBS disability score and Medical Research Council sum score at 1 month after admission. In an electrophysiologic analysis, the good outcome group showed greater amplitude of median, ulnar, deep peroneal, and posterior tibial nerve compound muscle action potentials (CMAP) and greater amplitude of median, ulnar, and superficial peroneal sensory nerve action potentials (SNAP) than the poor outcome group. A lower GBS disability score at admission, high amplitude of median, ulnar, deep peroneal, and posterior tibial CMAPs, and high amplitude of median, ulnar, and superficial peroneal SNAPs were associated with being able to walk at 1 month in patients with axonal GBS.
The Use of Artificial Neural Networks in Prediction of Congenital CMV Outcome from Sequence Data
Directory of Open Access Journals (Sweden)
Ravit Arav-Boger
2008-01-01
Full Text Available A large number of CMV strains has been reported to circulate in the human population, and the biological significance of these strains is currently an active area of research. The analysis of complex genetic information may be limited using conventional phylogenetic techniques. We constructed artificial neural networks to determine their feasibility in predicting the outcome of congenital CMV disease (defined as presence of CMV symptoms at birth based on two data sets: 54 sequences of CMV gene UL144 obtained from 54 amniotic fluids of women who contracted acute CMV infection during their pregnancy, and 80 sequences of 4 genes (US28, UL144, UL146 and UL147 obtained from urine, saliva or blood of 20 congenitally infected infants that displayed different outcomes at birth. When data from all four genes was used in the 20-infants’ set, the artificial neural network model accurately identified outcome in 90% of cases. While US28 and UL147 had low yield in predicting outcome, UL144 and UL146 predicted outcome in 80% and 85% respectively when used separately. The model identified specific nucleotide positions that were highly relevant to prediction of outcome. The artificial neural network classified genotypes in agreement with classic phylogenetic analysis. We suggest that artificial neural networks can accurately and efficiently analyze sequences obtained from larger cohorts to determine specific outcomes.The ANN training and analysis code is commercially available from Optimal Neural Informatics (Pikesville, MD.
Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study.
Rossetti, Andrea O; Tovar Quiroga, Diego F; Juan, Elsa; Novy, Jan; White, Roger D; Ben-Hamouda, Nawfel; Britton, Jeffrey W; Oddo, Mauro; Rabinstein, Alejandro A
2017-07-01
The prognostic role of electroencephalography during and after targeted temperature management in postcardiac arrest patients, relatively to other predictors, is incompletely known. We assessed performances of electroencephalography during and after targeted temperature management toward good and poor outcomes, along with other recognized predictors. Cohort study (April 2009 to March 2016). Two academic hospitals (Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland; Mayo Clinic, Rochester, MN). Consecutive comatose adults admitted after cardiac arrest, identified through prospective registries. All patients were managed with targeted temperature management, receiving prespecified standardized clinical, neurophysiologic (particularly, electroencephalography during and after targeted temperature management), and biochemical evaluations. We assessed electroencephalography variables (reactivity, continuity, epileptiform features, and prespecified "benign" or "highly malignant" patterns based on the American Clinical Neurophysiology Society nomenclature) and other clinical, neurophysiologic (somatosensory-evoked potential), and biochemical prognosticators. Good outcome (Cerebral Performance Categories 1 and 2) and mortality predictions at 3 months were calculated. Among 357 patients, early electroencephalography reactivity and continuity and flexor or better motor reaction had greater than 70% positive predictive value for good outcome; reactivity (80.4%; 95% CI, 75.9-84.4%) and motor response (80.1%; 95% CI, 75.6-84.1%) had highest accuracy. Early benign electroencephalography heralded good outcome in 86.2% (95% CI, 79.8-91.1%). False positive rates for mortality were less than 5% for epileptiform or nonreactive early electroencephalography, nonreactive late electroencephalography, absent somatosensory-evoked potential, absent pupillary or corneal reflexes, presence of myoclonus, and neuron-specific enolase greater than 75 µg/L; accuracy was highest for
Zhang, Nan; Wang, Wentao; Zhu, Xiaonong; Liu, Jiansheng; Xu, Kuanhong; Huang, Peng; Zhao, Jiefeng; Li, Ruxin; Wang, Mingwei
2011-04-25
50 fs - 12 ps laser pulses are employed to ablate aluminum, copper, iron, and graphite targets. The ablation-generated momentum is measured with a torsion pendulum. Corresponding time-resolved shadowgraphic measurements show that the ablation process at the optimal laser fluence achieving the maximal momentum is primarily dominated by the photomechanical mechanism. When laser pulses with specific laser fluence are used and the pulse duration is tuned from 50 fs to 12 ps, the generated momentum firstly increases and then remains almost constant, which could be attributed to the change of the ablation mechanism involved from atomization to phase explosion. The investigation of the ablation-generated momentum also reveals a nonlinear momentum-energy conversion scaling law, namely, as the pulse energy increases, the momentum obtained by the target increases nonlinearly. This may be caused by the effective reduction of the dissipated energy into the surrounding of the ablation zone as the pulse energy increases, which indicates that for femtosecond laser the dissipated energy into the surrounding target is still significant.
Beck-Broichsitter, Benedicta E; Huck, Jörn; Küchler, Thomas; Hauke, Daniela; Hedderich, Jürgen; Wiltfang, Jörg; Becker, Stephan T
2017-02-01
The extent of functional impairment after ablative surgery in the orofacial region may be directly reflected in a reduction in Quality of Life. This study intended to compare the patients' perception with an objective functional evaluation of the orofacial system in order to bilaterally distinguish direct influence factors. A total of 45 patients were included in this study and were asked to complete the European Organisation for Research and Treatment of Cancer Core Questionnaire (EORTC QLQ-30) and the Head and Neck 35 Module (H&N 35). Afterward one independent speech therapist evaluated the patients applying the Frenchay Dysarthria Assessment regarding four main categories: mouth opening, tongue motility, swallowing and intelligibility. Comparisons between groups were performed using Whitney-Mann U-Wilcoxon test and calculating Spearman's rho. Overall the professional assessments by the speech therapists revealed significantly higher scores regarding intelligibility, swallowing and mouth opening when compared to the patients' self-perception. Smaller tumor sizes, no bone resection and local reconstruction techniques led to significantly better functional outcomes, when assessed by speech therapists. Swallowing was perceived significantly better by patients in cases of local reconstruction. From the professionals' point of view differences were perceived in more items compared to the patients' self-assessments, who widely experienced a more severe functional impairment. Physicians should take this into account when discussing adverse therapy effects with the patients.
Femtosecond laser ablation of enamel
Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui
2016-06-01
The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.
Pediatric extracorporeal shock wave lithotripsy: Predicting successful outcomes
Directory of Open Access Journals (Sweden)
Sean McAdams
2010-01-01
Full Text Available Extracorporeal shock wave lithotripsy (ESWL is currently a first-line procedure of most upper urinary tract stones <2 cm of size because of established success rates, its minimal invasiveness and long-term safety with minimal complications. Given that alternative surgical and endourological options exist for the management of stone disease and that ESWL failure often results in the need for repeat ESWL or secondary procedures, it is highly desirable to identify variables predicting successful outcomes of ESWL in the pediatric population. Despite numerous reports and growing experience, few prospective studies and guidelines for pediatric ESWL have been completed. Variation in the methods by which study parameters are measured and reported can make it difficult to compare individual studies or make definitive recommendations. There is ongoing work and a need for continuing improvement of imaging protocols in children with renal colic, with a current focus on minimizing exposure to ionizing radiation, perhaps utilizing advancements in ultrasound and magnetic resonance imaging. This report provides a review of the current literature evaluating the patient attributes and stone factors that may be predictive of successful ESWL outcomes along with reviewing the role of pre-operative imaging and considerations for patient safety.
Hadamard Kernel SVM with applications for breast cancer outcome predictions.
Jiang, Hao; Ching, Wai-Ki; Cheung, Wai-Shun; Hou, Wenpin; Yin, Hong
2017-12-21
Breast cancer is one of the leading causes of deaths for women. It is of great necessity to develop effective methods for breast cancer detection and diagnosis. Recent studies have focused on gene-based signatures for outcome predictions. Kernel SVM for its discriminative power in dealing with small sample pattern recognition problems has attracted a lot attention. But how to select or construct an appropriate kernel for a specified problem still needs further investigation. Here we propose a novel kernel (Hadamard Kernel) in conjunction with Support Vector Machines (SVMs) to address the problem of breast cancer outcome prediction using gene expression data. Hadamard Kernel outperform the classical kernels and correlation kernel in terms of Area under the ROC Curve (AUC) values where a number of real-world data sets are adopted to test the performance of different methods. Hadamard Kernel SVM is effective for breast cancer predictions, either in terms of prognosis or diagnosis. It may benefit patients by guiding therapeutic options. Apart from that, it would be a valuable addition to the current SVM kernel families. We hope it will contribute to the wider biology and related communities.
Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation
International Nuclear Information System (INIS)
Clasen, Stephan; Kettenbach, Joachim; Kosan, Bora; Aebert, Hermann; Schernthaner, Melanie; Kroeber, Stefan-Martin; Boemches, Andrea; Claussen, Claus D.; Pereira, Philippe L.
2009-01-01
Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.
Steady ablation on the surface of a two-layer composite
Energy Technology Data Exchange (ETDEWEB)
Lin, Wen-Shan [Chung Shan Institute of Science and Technology, P.O. Box 90008-15-3, Lung-Tan, Tao-Yuan, 32526 Taiwan (China)
2005-12-01
Discovered is a quasi-steady ablation phenomenon on the surface of a two-layer composite which is formed by a layer of ablative material and another layer of non-ablative substrate. Theoretical exact solutions of quasi-steady ablation rate, the associated temperature distribution and end-of-ablation time of this two-layer composite are derived. A criterion for the occurrence of quasi-steady ablation is presented also. A one-dimensional transient numerical model is developed to perform a number of numerical experiments and hence to verify the correctness of the above theoretical solutions for the current quasi-steady ablation phenomenon. Based on the current results, a new method of measuring the ablation (or sublimation) heat is also proposed. (author)
Leptomeningeal collateral status predicts outcome after middle cerebral artery occlusion
DEFF Research Database (Denmark)
Madelung, Christopher Fugl; Ovesen, C; Trampedach, C
2017-01-01
NCCT and according to European Cooperative Acute Stroke Study (ECASS) criteria. Modified Rankin Scale score was assessed at 90 days, and mortality at 1 year. RESULTS: At 90 days, median (IQR) modified Rankin Scale score in patients with poor collateral status was 4 (3-6) compared to 2 (1-4) in patients...... population (P = .001). CONCLUSIONS: Leptomeningeal collateral status predicts functional outcome, mortality, and hemorrhagic transformation following middle cerebral artery occlusion.......OBJECTIVES: Perfusion through leptomeningeal collateral vessels is a likely pivotal factor in the outcome of stroke patients. We aimed to investigate the effect of collateral status on outcome in a cohort of unselected, consecutive stroke patients with middle cerebral artery occlusion undergoing...
Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal
2015-04-01
Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.
Yin, J. J.; Chang, F.; Li, S. L.; Yao, X. L.; Sun, J. R.; Xiao, Y.
2017-10-01
According to the mathematical analysis model constructed on the basis of energy-balance relationship in lightning strike, and accompany with the simplified calculation strategy of composite resin pyrolysis degree dependent electrical conductivity, an effective three dimensional thermal-electrical coupling analysis finite element model of composite laminate suffered from lightning current was established based on ABAQUS, to elucidate the effects of lighting current waveform parameters and thermal/electrical properties of composite laminate on the extent of ablation damage. Simulated predictions agree well with the composite lightning strike directed effect experimental data, illustrating the potential accuracy of the constructed model. The analytical results revealed that extent of composite lightning strike ablation damage can be characterized by action integral validly, there exist remarkable power function relationships between action integral and visual damage area, projected damage area, maximum damage depth and damage volume of ablation damage, and enhancing the electrical conductivity and specific heat of composite, ablation damage will be descended obviously, power function relationships also exist between electrical conductivity, specific heat and ablation damage, however, the impact of thermal conductivity on the extent of ablation damage is not notable. The conclusions obtained provide some guidance for composite anti-lightning strike structure-function integration design.
A review of the safety aspects of radio frequency ablation
Directory of Open Access Journals (Sweden)
Abhishek Bhaskaran
2015-09-01
Full Text Available In light of recent reports showing high incidence of silent cerebral infarcts and organized atrial arrhythmias following radiofrequency (RF atrial fibrillation (AF ablation, a review of its safety aspects is timely. Serious complications do occur during supraventricular tachycardia (SVT ablations and knowledge of their incidence is important when deciding whether to proceed with ablation. Evidence is emerging for the probable role of prophylactic ischemic scar ablation to prevent VT. This might increase the number of procedures performed. Here we look at the various complications of RF ablation and also the methods to minimize them. Electronic database was searched for relevant articles from 1990 to 2015. With better awareness and technological advancements in RF ablation the incidence of complications has improved considerably. In AF ablation it has decreased from 6% to less than 4% comprising of vascular complications, cardiac tamponade, stroke, phrenic nerve injury, pulmonary vein stenosis, atrio-esophageal fistula (AEF and death. Safety of SVT ablation has also improved with less than 1% incidence of AV node injury in AVNRT ablation. In VT ablation the incidence of major complications was 5–11%, up to 3.4%, up to 1.8% and 4.1–8.8% in patients with structural heart disease, without structural heart disease, prophylactic ablations and epicardial ablations respectively. Vascular and pericardial complications dominated endocardial and epicardial VT ablations respectively. Up to 3% mortality and similar rates of tamponade were reported in endocardial VT ablation. Recent reports about the high incidence of asymptomatic cerebral embolism during AF ablation are concerning, warranting more research into its etiology and prevention.
Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine
2010-12-01
To evaluate the accuracy of the ablation depth readout for the MEL 80 excimer laser (Carl Zeiss Meditec). Artemis 1 very high-frequency digital ultrasound measurements were obtained before and at least 3 months after LASIK in 121 eyes (65 patients). The Artemis-measured ablation depth was calculated as the maximum difference in stromal thickness before and after treatment. Laser in situ keratomileusis was performed using the MEL 80 excimer laser and the Hansatome microkeratome (Bausch & Lomb). The Aberration Smart Ablation profile was used in 56 eyes and the Tissue Saving Ablation profile was used in 65 eyes. All ablations were centered on the corneal vertex. Comparative statistics and linear regression analysis were performed between the laser readout ablation depth and Artemis-measured ablation depth. The mean maximum myopic meridian was -6.66±2.40 diopters (D) (range: -1.50 to -10.00 D) for Aberration Smart Ablation-treated eyes and -6.50±2.56 D (range: -1.34 to -11.50 D) for Tissue Saving Ablation-treated eyes. The MEL 80 readout was found to overestimate the Artemis-measured ablation depth by 20±12 μm for Aberration Smart Ablation and by 21±12 μm for Tissue Saving Ablation profiles. The accuracy of ablation depth measurement was improved by using the Artemis stromal thickness profile measurements before and after surgery to exclude epithelial changes. The MEL 80 readout was found to overestimate the achieved ablation depth. The linear regression equations could be used by MEL 80 users to adjust the ablation depth for predicted residual stromal thickness calculations without increasing the risk of ectasia due to excessive keratectomy depth as long as a suitable flap thickness bias is included. Copyright 2010, SLACK Incorporated.
International Nuclear Information System (INIS)
Cockburn, J.F.; Maddern, G.J.; Wemyss-Holden, S.A.
2007-01-01
Aim: To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Materials and methods: Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Ω or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. Results: With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p < 0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Conclusion: Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone
Endometrial ablation: normal appearance and complications.
Drylewicz, Monica R; Robinson, Kathryn; Siegel, Cary Lynn
2018-03-14
Global endometrial ablation is a commonly performed, minimally invasive technique aimed at improving/resolving abnormal uterine bleeding and menorrhagia in women. As non-resectoscopic techniques have come into existence, endometrial ablation performance continues to increase due to accessibility and decreased requirements for operating room time and advanced technical training. The increased utilization of this method translates into increased imaging of patients who have undergone the procedure. An understanding of the expected imaging appearances of endometrial ablation using different modalities is important for the abdominal radiologist. In addition, the frequent usage of the technique naturally comes with complications requiring appropriate imaging work-up. We review the expected appearance of the post-endometrial ablated uterus on multiple imaging modalities and demonstrate the more common and rare complications seen in the immediate post-procedural time period and remotely.
International Nuclear Information System (INIS)
Mikami, Koji; Osuga, Keigo; Tomoda, Kaname; Nakamura, Hironobu; Murakami, Takamichi; Okada, Atsuya
2008-01-01
The aim of this study was to assess the feasibility and effectiveness of magnetic resonance (MRI)-guided focused ultrasound (MRIgFUS) ablation for uterine fibroids and to identify the candidates for this treatment. A total of 48 patients with a symptomatic uterine fibroid underwent MRIgFUS. The percent ablation volume was calculated, and the patients' characteristics and the MR imaging features of the fibroids that might predict the effect of this treatment were assessed. Changes in the symptoms related to the uterine fibroid were assessed at 6 and 12 months. The planned target zone were successfully treated in 32 patients with bulk-related and menstrual symptoms but unsuccessfully treated in the remaining 16 patients. These 16 patients were obese or their uterine fibroid showed heterogeneous high signal intensity on T2-weighted images. The 32 successfully treated patients were followed up for 6 months. At the 6-month follow-up, bulk-related and menstrual symptoms were diminished in 60% and 51% of patients, respectively. Among them, 17 patients were followed up for 12 months, and 9 of them who showed alleviation of bulk-related symptoms at 6 months had further improvement. The mean percent ablation volume of those nine patients was 51%. In 5 (33%) of the 15 patients with alleviation of menstrual symptoms at 6 months, the symptoms became worse at 12 months. There was a significant difference in the mean percent ablation volume between patients with alleviation of menstrual symptoms and those without (54% vs. 37%; P=0.03). MRIgFUS ablation is a safe, effective treatment for nonobese patients with symptomatic fibroids that show low signal intensity on T2-weighted images. Ablation of more than 50% of the fibroid volume may be needed with a short-term follow-up. (author)
Kymionis, George D; Panagopoulou, Sophia I; Aslanides, Ioannis M; Plainis, Sotiris; Astyrakakis, Nikolaos; Pallikaris, Ioannis G
2004-05-01
To evaluate the efficacy, predictability, and safety of topographically supported customized ablations (TOSCAs) for decentered ablations following laser in situ keratomileusis (LASIK). Prospective nonrandomized clinical trial. Nine patients (11 eyes) with LASIK-induced decentered ablations underwent TOSCA following flap lifting. Topographically supported customized ablation was performed using a corneal topographer to obtain a customized ablation profile, combined with a flying spot laser. Mean follow-up was 9.22 +/- 2.82 months (range 6-12 months). No intra- or postoperative complications were observed. Manifest refraction (spherical equivalent) did not change significantly (pre-TOSCA: -0.14 +/- 1.58 diopters [range, -1.75 to +3.00 diopters] to +0.46 +/- 1.02 diopters [range, -1.00 to +1.75 diopters]; P =.76), whereas there was a statistically significant reduction in the refractive astigmatism (pre-TOSCA: -1.55 +/- 0.60 diopters [range, -3.00 to -0.75 diopters] to -0.70 +/- 0.56 diopters [range, -2.00 to -0.25 diopters]; P =.003). Mean uncorrected visual acuity improved significantly (P <.001) from 0.45 +/- 0.16 (range, 0.2-0.7) to 0.76 +/- 0.29 (range, 0.2-1.2) at last follow-up. Mean best-corrected visual acuity improved from 0.74 +/- 0.22 (range, 0.4-1.0) to 0.95 +/- 0.20 (range, 0.6-1.2; P =.002). Eccentricity showed a statistically significant reduction after TOSCA treatment (pre-TOSCA: 1.59 +/- 0.46 mm [range, 0.88-2.23 mm]; post-TOSCA: 0.29 +/- 0.09 mm [range, 0.18-0.44 mm]; P <.001). In our small sample, enhancement LASIK procedures with TOSCA appear to improve uncorrected and best-corrected visual acuity as well as eccentricity in patients with LASIK-induced decentered ablation.
International Nuclear Information System (INIS)
Gebauer, B.; Collettini, F.; Bruger, C.; Streitparth, F.; Schaser, K.D.; Melcher, I.; Tunn, P.U.
2013-01-01
Purpose: To review the long term clinical outcomes in the treatment of osteoid osteoma (OO) using radiofrequency ablation (RFA). Materials and Methods: Our retrospective study included 59 patients who were treated in the period from April 2001 to December 2012 due to a symptomatic OO using RFA. Here, the occurrence of complications and postoperative recurrence, as well as postoperative patient satisfaction were examined. Patients satisfaction was assessed by means of a telephone interview with the visual analogue scale (VAS). Results: Mean follow-up was 50 months (2 - 116 months). The average size of the nidus was 6 mm (range 2 - 14 mm). After initial radiofrequency ablation 11.8 % (7/59) of patient showed a recurrence of symptoms. Symptoms could successfully be treated by a second ablation in 5 patients. Assisted success rate was therefore 96.6 % (57/59). The complication rate was 5.1 % (2 major and one minor complication). Furthermore we report a very high patient satisfaction and acceptance of therapy. Conclusion: RFA is a very successful therapy of symptomatic OOs with a high patient satisfaction. (orig.)
Sondag, Lotte; Ruijter, Barry J; Tjepkema-Cloostermans, Marleen C; Beishuizen, Albertus; Bosch, Frank H; van Til, Janine A; van Putten, Michel J A M; Hofmeijer, Jeannette
2017-05-15
We recently showed that electroencephalography (EEG) patterns within the first 24 hours robustly contribute to multimodal prediction of poor or good neurological outcome of comatose patients after cardiac arrest. Here, we confirm these results and present a cost-minimization analysis. Early prognosis contributes to communication between doctors and family, and may prevent inappropriate treatment. A prospective cohort study including 430 subsequent comatose patients after cardiac arrest was conducted at intensive care units of two teaching hospitals. Continuous EEG was started within 12 hours after cardiac arrest and continued up to 3 days. EEG patterns were visually classified as unfavorable (isoelectric, low-voltage, or burst suppression with identical bursts) or favorable (continuous patterns) at 12 and 24 hours after cardiac arrest. Outcome at 6 months was classified as good (cerebral performance category (CPC) 1 or 2) or poor (CPC 3, 4, or 5). Predictive values of EEG measures and cost-consequences from a hospital perspective were investigated, assuming EEG-based decision- making about withdrawal of life-sustaining treatment in the case of a poor predicted outcome. Poor outcome occurred in 197 patients (51% of those included in the analyses). Unfavorable EEG patterns at 24 hours predicted a poor outcome with specificity of 100% (95% CI 98-100%) and sensitivity of 29% (95% CI 22-36%). Favorable patterns at 12 hours predicted good outcome with specificity of 88% (95% CI 81-93%) and sensitivity of 51% (95% CI 42-60%). Treatment withdrawal based on an unfavorable EEG pattern at 24 hours resulted in a reduced mean ICU length of stay without increased mortality in the long term. This gave small cost reductions, depending on the timing of withdrawal. Early EEG contributes to reliable prediction of good or poor outcome of postanoxic coma and may lead to reduced length of ICU stay. In turn, this may bring small cost reductions.
The use of presurgical psychological screening to predict the outcome of spine surgery.
Block, A R; Ohnmeiss, D D; Guyer, R D; Rashbaum, R F; Hochschuler, S H
2001-01-01
Several previous studies have shown that psychosocial factors can influence the outcome of elective spine surgery. The purpose of the current study was to determine how well a presurgical screening instrument could predict surgical outcome. The study was conducted by staff of a psychologist's office. They performed preoperative screening for spine surgery candidates and collected the follow-up data. Presurgical screening and follow-up data collection was performed on 204 patients who underwent laminectomy/discectomy (n=118) or fusion (n=86) of the lumbar spine. The outcome measures used in the study were visual analog pain scales, the Oswestry Disability Questionnaire, and medication use. A semi-structured interview and psychometric testing were used to identify specific, quantifiable psychological, and "medical" risk factors for poor surgical outcome. A presurgical psychological screening (PPS) scorecard was completed for each patient, assessing whether the patient had a high or low level of risk on these psychological and medical dimensions. Based on the scorecard, an overall surgical prognosis of "good," "fair," or "poor" was generated. Results showed spine surgery led to significant overall improvements in pain, functional ability, and medication use. Medical and psychological risk levels were significantly related to outcome, with the poorest results obtained by patients having both high psychological and medical risk. Further, the accuracy of PPS surgical prognosis in predicting overall outcome was 82%. Only 9 of 53 patients predicted to have poor outcome achieved fair or good results from spine surgery. These findings suggest that PPS should become a more routine part of the evaluation of chronic pain patients in whom spine surgery is being considered.
International Nuclear Information System (INIS)
Yu Jie; Liang Ping; Yu Xiaoling; Liu Fangyi; Chen Lei; Wang Yang
2011-01-01
Purpose: The purpose of this study was to compare the effectiveness of microwave (MW) ablation and radiofrequency (RF) ablation using a single internally cooled probe in a hepatic porcine model. Materials and methods: In the ex vivo experiment, MW ablations (n = 40) were performed with a 2450 MHz and 915 MHz needle antenna, respectively at 60 W, 70 W power settings. Bipolar RF ablations (n = 20) were performed with a 3-cm (T30) and 4-cm (T40) active tip needle electrodes, respectively at a rated power 30 W and 40 W according to automatically systematic power setting. In the in vivo experiment, the 2450 MHz and 915 MHz MW ablation both at 60 W and T30 bipolar RF ablation at 30 W were performed (n = 30). All of the application time were 10 min. Long-axis diameter (Dl), short-axis diameter (Ds), ratio of Ds/Dl, the temperature data 5 mm from the needle and the time of temperature 5 mm from the needle rising to 54 deg. C were measured. Results: Both in ex vivo and in vivo models, Ds and Dl of 915 MHz MW ablations were significantly larger than all the RF ablations (P < 0.05); the Ds for all the 2450 MHz MW ablations were significantly larger than that of T30 RF ablations (P < 0.05). 2450 MHz MW and T30 RF ablation tended to produce more elliptical-shaped ablation zone. Tissue temperatures 5 mm from the needle were considerably higher with MW ablation, meanwhile MW ablation achieved significantly faster rate of temperature rising to 54 deg. C than RF ablation. For in vivo study after 10 min of ablation, the Ds and Dl of 2450 MHz MW, 915 MHz MW and Bipolar RF were 2.35 ± 0.75, 2.95 ± 0.32, 1.61 ± 0.33 and 3.86 ± 0.81, 5.79 ± 1.03, 3.21 ± 0.51, respectively. Highest tissue temperatures 5 mm from the needle were 80.07 ± 12.82 deg. C, 89.07 ± 3.52 deg. C and 65.56 ± 15.31 deg. C and the time of temperature rising to 54 deg. C were respectively 37.50 ± 7.62 s, 24.50 ± 4.09 s and 57.29 ± 23.24 s for three applicators. Conclusion: MW ablation may have higher
Alexander, D. A.; Naji, A. A.; Pinion, S. B.; Mollison, J.; Kitchener, H. C.; Parkin, D. E.; Abramovich, D. R.; Russell, I. T.
1996-01-01
OBJECTIVE: To compare in psychiatric and psychosocial terms the outcome of hysterectomy and endometrial ablation for the treatment of dysfunctional uterine bleeding. DESIGN: Prospective randomised controlled trial. SETTING--Obstetrics and gynaecology department of a large teaching hospital. SUBJECTS: 204 women with dysfunctional bleeding for whom hysterectomy would have been the preferred treatment were recruited over 24 months and randomly allocated to hysterectomy (99 women) or to hysteroscopic surgery (transcervical resection (52 women) or laser ablation (53 women). MAIN OUTCOME MEASURES: Mental state, martial relationship, psychosocial and sexual adjustment in assessments conducted before the operation and one month, six months, and 12 months later. RESULTS: Both treatments significantly reduced the anxiety and depression present before the operation, and there were no differences in mental health between the groups at 12 months. Hysterectomy did not lead to postoperative psychiatric illness. Sexual interest after the operation did not vary with treatment. Overall, 46 out of 185 (25%) women reported a loss sexual interest and 50 out of 185 (27%) reported increased sexual interest. Marital relationships were unaffected by surgery. Personality and duration of dysfunctional uterine bleeding played no significant part in determining outcome. CONCLUSIONS: Hysteroscopic surgery and hysterectomy have a similar effect on psychiatric and psychosocial outcomes. There is no evidence that hysterectomy leads to postoperative psychiatric illness. PMID:8611783
Leg pain and psychological variables predict outcome 2-3 years after lumbar fusion surgery.
Abbott, Allan D; Tyni-Lenné, Raija; Hedlund, Rune
2011-10-01
Prediction studies testing a thorough range of psychological variables in addition to demographic, work-related and clinical variables are lacking in lumbar fusion surgery research. This prospective cohort study aimed at examining predictions of functional disability, back pain and health-related quality of life (HRQOL) 2-3 years after lumbar fusion by regressing nonlinear relations in a multivariate predictive model of pre-surgical variables. Before and 2-3 years after lumbar fusion surgery, patients completed measures investigating demographics, work-related variables, clinical variables, functional self-efficacy, outcome expectancy, fear of movement/(re)injury, mental health and pain coping. Categorical regression with optimal scaling transformation, elastic net regularization and bootstrapping were used to investigate predictor variables and address predictive model validity. The most parsimonious and stable subset of pre-surgical predictor variables explained 41.6, 36.0 and 25.6% of the variance in functional disability, back pain intensity and HRQOL 2-3 years after lumbar fusion. Pre-surgical control over pain significantly predicted functional disability and HRQOL. Pre-surgical catastrophizing and leg pain intensity significantly predicted functional disability and back pain while the pre-surgical straight leg raise significantly predicted back pain. Post-operative psychomotor therapy also significantly predicted functional disability while pre-surgical outcome expectations significantly predicted HRQOL. For the median dichotomised classification of functional disability, back pain intensity and HRQOL levels 2-3 years post-surgery, the discriminative ability of the prediction models was of good quality. The results demonstrate the importance of pre-surgical psychological factors, leg pain intensity, straight leg raise and post-operative psychomotor therapy in the predictions of functional disability, back pain and HRQOL-related outcomes.
International Nuclear Information System (INIS)
Jyoti, Rajeev; O'Neil, Ross
2006-01-01
MRI is an established investigation in the evaluation of neonates with suspected hypoxic-ischaemic encephalopathy (HIE). However, its role as a predictor of neurodevelopmental outcome remains complex. To establish reproducible simplified MR criteria and evaluate their role in predicting neurodevelopmental outcome in term neonates with HIE. Term neonates with suspected HIE had MRI at 7-10 days of age. MR scans were interpreted according to new simplified criteria by two radiologists blinded to the clinical course and outcome. The new simplified criteria allocated grade 1 to cases with no central and less than 10% peripheral change, grade 2 to those with less than 30% central and/or 10-30% peripheral area change, and grade 3 to those with more than 30% central or peripheral change. MRI changes were compared with clinical neurodevelopmental outcome evaluated prospectively at 1 year of age. Neurodevelopmental outcome was based upon the DQ score (revised Griffith's) and cerebral palsy on neurological assessment. Of 20 subjects, all those showing severe (grade 3) MR changes (35%) died or had poor neurodevelopmental outcome. Subjects with a normal MR scan or with scans showing only mild (grade 1) MR changes (55%) had normal outcomes. One subject showing moderate (grade 2) changes on MRI had a moderate outcome (5%), while another had an atypical pattern of MR changes with a normal outcome (5%). Assessment of full-term neonates with suspected HIE using the simplified MR criteria is highly predictive of neurodevelopmental outcome. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Jyoti, Rajeev; O' Neil, Ross [Canberra Hospital, Medical Imaging, Canberra, ACT (Australia)
2006-01-01
MRI is an established investigation in the evaluation of neonates with suspected hypoxic-ischaemic encephalopathy (HIE). However, its role as a predictor of neurodevelopmental outcome remains complex. To establish reproducible simplified MR criteria and evaluate their role in predicting neurodevelopmental outcome in term neonates with HIE. Term neonates with suspected HIE had MRI at 7-10 days of age. MR scans were interpreted according to new simplified criteria by two radiologists blinded to the clinical course and outcome. The new simplified criteria allocated grade 1 to cases with no central and less than 10% peripheral change, grade 2 to those with less than 30% central and/or 10-30% peripheral area change, and grade 3 to those with more than 30% central or peripheral change. MRI changes were compared with clinical neurodevelopmental outcome evaluated prospectively at 1 year of age. Neurodevelopmental outcome was based upon the DQ score (revised Griffith's) and cerebral palsy on neurological assessment. Of 20 subjects, all those showing severe (grade 3) MR changes (35%) died or had poor neurodevelopmental outcome. Subjects with a normal MR scan or with scans showing only mild (grade 1) MR changes (55%) had normal outcomes. One subject showing moderate (grade 2) changes on MRI had a moderate outcome (5%), while another had an atypical pattern of MR changes with a normal outcome (5%). Assessment of full-term neonates with suspected HIE using the simplified MR criteria is highly predictive of neurodevelopmental outcome. (orig.)
International Nuclear Information System (INIS)
Tacke, J.; Mahnken, A.; Buecker, A.; Guenther, R.W.; Rohde, D.
2001-01-01
Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 μm) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency intervention revealed no signs of residual tumor growth. Conclusion: The combined transcatheter embolization and percutaneous radiofrequency ablation of renal cell carcinoma has proved technically feasible, effective, and safe in this patient. It may be offered as an alternative treatment to partial or radical nephrectomy under certain circumstances. Abbreviations: RF = radiofrequency ablation; CT = computed tomography; HIV = human immunodeficiency virus. (orig.) [de
Factors Limiting Complete Tumor Ablation by Radiofrequency Ablation
International Nuclear Information System (INIS)
Paulet, Erwan; Aube, Christophe; Pessaux, Patrick; Lebigot, Jerome; Lhermitte, Emilie; Oberti, Frederic; Ponthieux, Anne; Cales, Paul; Ridereau-Zins, Catherine; Pereira, Philippe L.
2008-01-01
The purpose of this study was to determine radiological or physical factors to predict the risk of residual mass or local recurrence of primary and secondary hepatic tumors treated by radiofrequency ablation (RFA). Eighty-two patients, with 146 lesions (80 hepatocellular carcinomas, 66 metastases), were treated by RFA. Morphological parameters of the lesions included size, location, number, ultrasound echogenicity, computed tomography density, and magnetic resonance signal intensity were obtained before and after treatment. Parameters of the generator were recorded during radiofrequency application. The recurrence-free group was statistically compared to the recurrence and residual mass groups on all these parameters. Twenty residual masses were detected. Twenty-nine lesions recurred after a mean follow-up of 18 months. Size was a predictive parameter. Patients' sex and age and the echogenicity and density of lesions were significantly different for the recurrence and residual mass groups compared to the recurrence-free group (p < 0.05). The presence of an enhanced ring on the magnetic resonance control was more frequent in the recurrence and residual mass groups. In the group of patients with residual lesions, analysis of physical parameters showed a significant increase (p < 0.05) in the time necessary for the temperature to rise. In conclusion, this study confirms risk factors of recurrence such as the size of the tumor and emphasizes other factors such as a posttreatment enhanced ring and an increase in the time necessary for the rise in temperature. These factors should be taken into consideration when performing RFA and during follow-up
Comparison of the Three NIF Ablators
Energy Technology Data Exchange (ETDEWEB)
Kritcher, A. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Clark, D. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haan, S. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Yi, S. A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zylstra, A. B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ralph, J. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Weber, C. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
2017-11-01
Indirect drive implosion experiments on NIF have now been performed using three different ablator materials: glow discharge polymer (GDP) or CH, high density carbon (HDC, which we also refer to as diamond), and sputtered beryllium (Be). It has been appreciated for some time that each of these materials has specific advantages and disadvantages as an ICF ablator.[1-4] In light of experiments conducted on NIF in the last few years, how do these ablators compare? Given current understanding, is any ablator more or less likely to reach ignition on NIF? Has the understanding of their respective strengths and weaknesses changed since NIF experiments began? How are those strengths and weaknesses highlighted by implosion designs currently being tested or planned for testing soon? This document aims to address these questions by combining modern simulation results with a survey of the current experimental data base. More particularly, this document is meant to fulfill an L2 Milestone for FY17 to “Document our understanding of the relative advantages and disadvantages of CH, HDC, and Be designs.” Note that this document does not aim to recommend a down-selection of the current three ablator choices. It is intended only to gather and document the current understanding of the differences between these ablators and thereby inform the choices made in planning future implosion experiments. This document has two themes: (i) We report on a reanalysis project in which post-shot simulations were done on a common basis for layered shots using each ablator. This included data from keyholes, 2D ConA, and so forth, from each campaign, leading up to the layered shots. (“Keyholes” are shots dedicated to measuring the shock timing in a NIF target, as described in Ref. 5. “2DConAs” are backlit implosions in which the symmetry of the implosion is measured between about half and full convergence, as described in Ref. 6.) This set of common-basis postshot simulations is compared to
Radioiodine Remnant Ablation: A Critical Review
International Nuclear Information System (INIS)
Bal, Chandra Sekhar; Padhy, Ajit Kumar
2015-01-01
Radioiodine remnant ablation (RRA) is considered a safe and effective method for eliminating residual thyroid tissue, as well as microscopic disease if at all present in thyroid bed following thyroidectomy. The rationale of RRA is that in the absence of thyroid tissue, serum thyroglobulin (Tg) measurement can be used as an excellent tumor marker. Other considerations are like the presence of significant remnant thyroid tissue makes detection and treatment of nodal or distant metastases difficult. Rarely, microscopic disease in the thyroid bed if not ablated, in the future, could be a source of anaplastic transformation. On the other hand, microscopic tumor emboli in distant sites could be the cause of distant metastasis too. The ablation of remnant tissue would in all probability eliminate these theoretical risks. It may be noted that all these are unproven contentious issues except postablation serum Tg estimation that could be a good tumor marker for detecting early biochemical recurrence in long-term follow-up strategy. Radioactive iodine is administered as a form of “adjuvant therapy” for remnant ablation. There have been several reports with regard to the administered dose for remnant ablation. The first report of a prospective randomized clinical trial was published from India by a prospective randomized study conducted at the All India Institute of Medical Sciences, New Delhi in the year 1996. The study reported that increasing the empirical 131 I initial dose to more than 50 mCi results in plateauing of the dose-response curve and thus, conventional high-dose remnant ablation needs critical evaluation. Recently, two important studies were published: One from French group and the other from UK on a similar line. Interestingly, all three studies conducted in three different geographical regions of the world showed exactly similar conclusion. The new era of low-dose remnant ablation has taken a firm scientific footing across the continents
Doucet, Gaelle E; Rider, Robert; Taylor, Nathan; Skidmore, Christopher; Sharan, Ashwini; Sperling, Michael; Tracy, Joseph I
2015-04-01
This study determined the ability of resting-state functional connectivity (rsFC) graph-theory measures to predict neurocognitive status postsurgery in patients with temporal lobe epilepsy (TLE) who underwent anterior temporal lobectomy (ATL). A presurgical resting-state functional magnetic resonance imaging (fMRI) condition was collected in 16 left and 16 right TLE patients who underwent ATL. In addition, patients received neuropsychological testing pre- and postsurgery in verbal and nonverbal episodic memory, language, working memory, and attention domains. Regarding the functional data, we investigated three graph-theory properties (local efficiency, distance, and participation), measuring segregation, integration and centrality, respectively. These measures were only computed in regions of functional relevance to the ictal pathology, or the cognitive domain. Linear regression analyses were computed to predict the change in each neurocognitive domain. Our analyses revealed that cognitive outcome was successfully predicted with at least 68% of the variance explained in each model, for both TLE groups. The only model not significantly predictive involved nonverbal episodic memory outcome in right TLE. Measures involving the healthy hippocampus were the most common among the predictors, suggesting that enhanced integration of this structure with the rest of the brain may improve cognitive outcomes. Regardless of TLE group, left inferior frontal regions were the best predictors of language outcome. Working memory outcome was predicted mostly by right-sided regions, in both groups. Overall, the results indicated our integration measure was the most predictive of neurocognitive outcome. In contrast, our segregation measure was the least predictive. This study provides evidence that presurgery rsFC measures may help determine neurocognitive outcomes following ATL. The results have implications for refining our understanding of compensatory reorganization and predicting
Fracture in Phenolic Impregnated Carbon Ablator
Agrawal, Parul; Chavez-Garcia, Jose; Pham, John
2013-01-01
This paper describes the development of a novel technique to understand the failure mechanisms inside thermal protection materials. The focus of this research is on the class of materials known as phenolic impregnated carbon ablators. It has successfully flown on the Stardust spacecraft and is the thermal protection system material chosen for the Mars Science Laboratory and SpaceX Dragon spacecraft. Although it has good thermal properties, structurally, it is a weak material. To understand failure mechanisms in carbon ablators, fracture tests were performed on FiberForm(Registered TradeMark) (precursor), virgin, and charred ablator materials. Several samples of these materials were tested to investigate failure mechanisms at a microstructural scale. Stress-strain data were obtained simultaneously to estimate the tensile strength and toughness. It was observed that cracks initiated and grew in the FiberForm when a critical stress limit was reached such that the carbon fibers separated from the binder. However, both for virgin and charred carbon ablators, crack initiation and growth occurred in the matrix (phenolic) phase. Both virgin and charred carbon ablators showed greater strength values compared with FiberForm samples, confirming that the presence of the porous matrix helps in absorbing the fracture energy.
Yang, Qinglin; Su, Yingying; Hussain, Mohammed; Chen, Weibi; Ye, Hong; Gao, Daiquan; Tian, Fei
2014-05-01
Burst suppression ratio (BSR) is a quantitative electroencephalography (qEEG) parameter. The purpose of our study was to compare the accuracy of BSR when compared to other EEG parameters in predicting poor outcomes in adults who sustained post-anoxic coma while not being subjected to therapeutic hypothermia. EEG was registered and recorded at least once within 7 days of post-anoxic coma onset. Electrodes were placed according to the international 10-20 system, using a 16-channel layout. Each EEG expert scored raw EEG using a grading scale adapted from Young and scored amplitude-integrated electroencephalography tracings, in addition to obtaining qEEG parameters defined as BSR with a defined threshold. Glasgow outcome scales of 1 and 2 at 3 months, determined by two blinded neurologists, were defined as poor outcome. Sixty patients with Glasgow coma scale score of 8 or less after anoxic accident were included. The sensitivity (97.1%), specificity (73.3%), positive predictive value (82.5%), and negative prediction value (95.0%) of BSR in predicting poor outcome were higher than other EEG variables. BSR1 and BSR2 were reliable in predicting death (area under the curve > 0.8, P coma who do not undergo therapeutic hypothermia when compared to other qEEG parameters.
Radiofrequency Ablation of Hepatic Cysts : Case Report
International Nuclear Information System (INIS)
Lee, Ye Ri; Kim, Pyo Nyun
2005-01-01
Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts
Directory of Open Access Journals (Sweden)
Gang Liu
2016-01-01
Full Text Available Objective. To test the value of quantifiable electrical stimuli as a reliable method to assess electroencephalogram reactivity (EEG-R for the early prognostication of outcome in comatose patients. Methods. EEG was recorded in consecutive adults in coma after cardiopulmonary resuscitation (CPR or stroke. EEG-R to standard electrical stimuli was tested. Each patient received a 3-month follow-up by the Glasgow-Pittsburgh cerebral performance categories (CPC or modified Rankin scale (mRS score. Results. Twenty-two patients met the inclusion criteria. In the CPR group, 6 of 7 patients with EEG-R had good outcomes (positive predictive value (PPV, 85.7% and 4 of 5 patients without EEG-R had poor outcomes (negative predictive value (NPV, 80%. The sensitivity and specificity were 85.7% and 80%, respectively. In the stroke group, 6 of 7 patients with EEG-R had good outcomes (PPV, 85.7%; all of the 3 patients without EEG-R had poor outcomes (NPV, 100%. The sensitivity and specificity were 100% and 75%, respectively. Of all patients, the presence of EEG-R showed 92.3% sensitivity, 77.7% specificity, 85.7% PPV, and 87.5% NPV. Conclusion. EEG-R to quantifiable electrical stimuli might be a good positive predictive factor for the prognosis of outcome in comatose patients after CPR or stroke.
International Nuclear Information System (INIS)
Blasco-Gimenez, Ramón; Lequerica, Juan L; Herrero, Maria; Hornero, Fernando; Berjano, Enrique J
2010-01-01
The aim of this work was to study linear deterministic models to predict tissue temperature during radiofrequency cardiac ablation (RFCA) by measuring magnitudes such as electrode temperature, power and impedance between active and dispersive electrodes. The concept involves autoregressive models with exogenous input (ARX), which is a particular case of the autoregressive moving average model with exogenous input (ARMAX). The values of the mode parameters were determined from a least-squares fit of experimental data. The data were obtained from radiofrequency ablations conducted on agar models with different contact pressure conditions between electrode and agar (0 and 20 g) and different flow rates around the electrode (1, 1.5 and 2 L min −1 ). Half of all the ablations were chosen randomly to be used for identification (i.e. determination of model parameters) and the other half were used for model validation. The results suggest that (1) a linear model can be developed to predict tissue temperature at a depth of 4.5 mm during RF cardiac ablation by using the variables applied power, impedance and electrode temperature; (2) the best model provides a reasonably accurate estimate of tissue temperature with a 60% probability of achieving average errors better than 5 °C; (3) substantial errors (larger than 15 °C) were found only in 6.6% of cases and were associated with abnormal experiments (e.g. those involving the displacement of the ablation electrode) and (4) the impact of measuring impedance on the overall estimate is negligible (around 1 °C)
Executive function processes predict mobility outcomes in older adults.
Gothe, Neha P; Fanning, Jason; Awick, Elizabeth; Chung, David; Wójcicki, Thomas R; Olson, Erin A; Mullen, Sean P; Voss, Michelle; Erickson, Kirk I; Kramer, Arthur F; McAuley, Edward
2014-02-01
To examine the relationship between performance on executive function measures and subsequent mobility outcomes in community-dwelling older adults. Randomized controlled clinical trial. Champaign-Urbana, Illinois. Community-dwelling older adults (N = 179; mean age 66.4). A 12-month exercise trial with two arms: an aerobic exercise group and a stretching and strengthening group. Established cognitive tests of executive function (flanker task, task switching, and a dual-task paradigm) and the Wisconsin card sort test. Mobility was assessed using the timed 8-foot up and go test and times to climb up and down a flight of stairs. Participants completed the cognitive tests at baseline and the mobility measures at baseline and after 12 months of the intervention. Multiple regression analyses were conducted to determine whether baseline executive function predicted postintervention functional performance after controlling for age, sex, education, cardiorespiratory fitness, and baseline mobility levels. Selective baseline executive function measurements, particularly performance on the flanker task (β = 0.15-0.17) and the Wisconsin card sort test (β = 0.11-0.16) consistently predicted mobility outcomes at 12 months. The estimates were in the expected direction, such that better baseline performance on the executive function measures predicted better performance on the timed mobility tests independent of intervention. Executive functions of inhibitory control, mental set shifting, and attentional flexibility were predictive of functional mobility. Given the literature associating mobility limitations with disability, morbidity, and mortality, these results are important for understanding the antecedents to poor mobility function that well-designed interventions to improve cognitive performance can attenuate. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.
Prediction of extubation outcome in preterm infants by composite extubation indices.
Dimitriou, Gabriel; Fouzas, Sotirios; Vervenioti, Aggeliki; Tzifas, Sotirios; Mantagos, Stefanos
2011-11-01
To determine whether composite extubation indices can predict extubation outcome in preterm infants. Prospective observational study. Level III neonatal intensive care unit. Fifty-six preterm infants cared for in the neonatal intensive care unit of a tertiary teaching hospital during 2007 and 2008. None. The study consisted of two parts. In the first part, different extubation indices were evaluated in a group of 28 neonates (derivation group). These indices included the diaphragmatic pressure-time index, the respiratory muscle pressure-time index, the maximal transdiaphragmatic pressure, the maximal inspiratory pressure, the airway pressure generated 100 milliseconds after an occlusion/maximal transdiaphragmatic pressure ratio, the airway pressure generated 100 milliseconds after an occlusion/maximal inspiratory pressure ratio, the tidal volume, and the respiratory rate to tidal volume ratio. After exploratory analysis, the best performing indices and the optimal threshold values to predict extubation outcome were selected. In the second part of the study, these indices were validated at the predetermined threshold values in an additional group of 28 preterm neonates (validation group). Four infants (14.3%) in the derivation group and four in the validation group (14.3%) failed extubation. Receiver operator characteristic curve analysis revealed that a diaphragmatic pressure-time index of ≤0.12, a respiratory muscle pressure-time index ≤0.10, a airway pressure generated 100 milliseconds after an occlusion/maximal transdiaphragmatic pressure of ≤0.14, and a airway pressure generated 100 milliseconds after an occlusion/maximal inspiratory pressure of ≤0.09 were the most accurate predictors of extubation outcome in the derivation group. In the validation group, a diaphragmatic pressure-time index of ≤0.12 and a respiratory muscle pressure-time index of ≤0.10 both had zero false-positive results, predicting with accuracy successful extubation. Composite
Elkhalil, Hossam; Akkin, Taner; Pearce, John; Bischof, John
2012-10-01
The photoselective vaporization of prostate (PVP) green light (532 nm) laser is increasingly being used as an alternative to the transurethral resection of prostate (TURP) for treatment of benign prostatic hyperplasia (BPH) in older patients and those who are poor surgical candidates. In order to achieve the goals of increased tissue removal volume (i.e., "ablation" in the engineering sense) and reduced collateral thermal damage during the PVP green light treatment, a two dimensional computational model for laser tissue ablation based on available parameters in the literature has been developed and compared to experiments. The model is based on the control volume finite difference and the enthalpy method with a mechanistically defined energy necessary to ablate (i.e., physically remove) a volume of tissue (i.e., energy of ablation E(ab)). The model was able to capture the general trends experimentally observed in terms of ablation and coagulation areas, their ratio (therapeutic index (TI)), and the ablation rate (AR) (mm(3)/s). The model and experiment were in good agreement at a smaller working distance (WD) (distance from the tissue in mm) and a larger scanning speed (SS) (laser scan speed in mm/s). However, the model and experiment deviated somewhat with a larger WD and a smaller SS; this is most likely due to optical shielding and heat diffusion in the laser scanning direction, which are neglected in the model. This model is a useful first step in the mechanistic prediction of PVP based BPH laser tissue ablation. Future modeling efforts should focus on optical shielding, heat diffusion in the laser scanning direction (i.e., including 3D effects), convective heat losses at the tissue boundary, and the dynamic optical, thermal, and coagulation properties of BPH tissue.
Bo, Xiao W; Li, Xiao L; Guo, Le H; Li, Dan D; Liu, Bo J; Wang, Dan; He, Ya P; Xu, Xiao H
2016-01-01
Objective: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. Methods: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. Results: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone + lateral necrotic zone + transitional zone) and necrotic zone (central necrotic zone + lateral necrotic zone) measured by VTIQ showed excellent correlation (r = 0.915, p 0.05). Conclusion: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. Advances in knowledge: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic
Energy Technology Data Exchange (ETDEWEB)
Kao, W.-Y. [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China); Chiou, Y.-Y., E-mail: yychiou@vghtpe.gov.tw [Department of Radiology, Taipei Veterans General Hospital, Taiwan (China); Faculty of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Hung, H.-H. [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China); Faculty of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Su, C.-W., E-mail: cwsu2@vghtpe.gov.tw [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China); Faculty of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Chou, Y.-H. [Department of Radiology, Taipei Veterans General Hospital, Taiwan (China); Faculty of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Wu, J.-C. [Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Medical Research and Education, Taipei Veterans General Hospital, Taiwan (China); Huo, T.-I. [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China); Institute of Pharmacology, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Huang, Y.-H. [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China); Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Wu, W.-C. [Division of Gastroenterology, Department of Medicine, Taipei Veterans General Hospital, Taiwan (China)
2012-05-15
Aims: To evaluate the clinical inference of serum alpha-fetoprotein (AFP) response in hepatocellular carcinoma (HCC) patients undergoing percutaneous radiofrequency ablation (RFA). Materials and methods: Three hundred and thirteen previously untreated HCC patients were enrolled in the study. The optimal AFP response was defined as >20% decrease from baseline after 1 month of RFA for those with a baseline AFP level of {>=}100 ng/ml. The impact of AFP response on prognosis was analysed and prognostic factors were assessed. Results: After a median follow-up of 26.7 {+-} 19.1 months, 49 patients died and 264 patients were alive. The cumulative 5 year survival rates were 75.3 and 57.4% in patients with an initial AFP of <100 ng/ml and {>=}100 ng/ml, respectively (p = 0.003). In the 58 patients with a baseline AFP of {>=}100 ng/ml and initial completed tumour necrosis after RFA, the cumulative 5 year survival rates were 62.4 and 25.7% in optimal and non-optimal AFP responders, respectively (p = 0.001). By multivariate analysis, the prothrombin time international normalized ratio >1.1 (p = 0.009), non-optimal AFP response (p = 0.023), and creatinine >1.5 mg/dl (p = 0.021) were independent risk factors predictive of poor overall survival. Besides, the cumulative 5 year recurrence rates were 83.4 and 100% in optimal and non-optimal AFP responders, respectively (p < 0.001). Multivariate analysis demonstrated platelet count {<=}10{sup 5}/mm{sup 3} (p = 0.048), tumour size >2 cm (p = 0.027), and non-optimal AFP response (p < 0.001) were independent risk factors associated with tumour recurrence after RFA. Conclusions: Serum AFP response may be a useful marker for predicting prognosis in HCC patients undergoing RFA.
Nanavati, Tania; Seemaladinne, Nirupama; Regier, Michael; Yossuck, Panitan; Pergami, Paola
2015-01-01
Background Neonatal hypoxic ischemic encephalopathy (HIE) is a major cause of mortality, morbidity, and long-term neurological deficits. Despite the availability of neuroimaging and neurophysiological testing, tools for accurate early diagnosis and prediction of developmental outcome are still lacking. The goal of this study was to determine if combined use of magnetic resonance imaging (MRI) and electroencephalography (EEG) findings could support outcome prediction. Methods We retrospectively reviewed records of 17 HIE neonates, classified brain MRI and EEG findings based on severity, and assessed clinical outcome up to 48 months. We determined the relation between MRI/EEG findings and clinical outcome. Results We demonstrated a significant relationship between MRI findings and clinical outcome (Fisher’s exact test, p = 0.017). EEG provided no additional information about the outcome beyond that contained in the MRI score. The statistical model for outcome prediction based on random forests suggested that EEG readings at 24 hours and 72 hours could be important variables for outcome prediction, but this needs to be investigated further. Conclusion Caution should be used when discussing prognosis for neonates with mild-to-moderate HIE based on early MR imaging and EEG findings. A robust, quantitative marker of HIE severity that allows for accurate prediction of long-term outcome, particularly for mild-to-moderate cases, is still needed. PMID:25862075
Cluster analysis as a prediction tool for pregnancy outcomes.
Banjari, Ines; Kenjerić, Daniela; Šolić, Krešimir; Mandić, Milena L
2015-03-01
Considering specific physiology changes during gestation and thinking of pregnancy as a "critical window", classification of pregnant women at early pregnancy can be considered as crucial. The paper demonstrates the use of a method based on an approach from intelligent data mining, cluster analysis. Cluster analysis method is a statistical method which makes possible to group individuals based on sets of identifying variables. The method was chosen in order to determine possibility for classification of pregnant women at early pregnancy to analyze unknown correlations between different variables so that the certain outcomes could be predicted. 222 pregnant women from two general obstetric offices' were recruited. The main orient was set on characteristics of these pregnant women: their age, pre-pregnancy body mass index (BMI) and haemoglobin value. Cluster analysis gained a 94.1% classification accuracy rate with three branch- es or groups of pregnant women showing statistically significant correlations with pregnancy outcomes. The results are showing that pregnant women both of older age and higher pre-pregnancy BMI have a significantly higher incidence of delivering baby of higher birth weight but they gain significantly less weight during pregnancy. Their babies are also longer, and these women have significantly higher probability for complications during pregnancy (gestosis) and higher probability of induced or caesarean delivery. We can conclude that the cluster analysis method can appropriately classify pregnant women at early pregnancy to predict certain outcomes.
Neutral and plasma shielding model for pellet ablation
International Nuclear Information System (INIS)
Houlberg, W.A.; Milora, S.L.; Attenberger, S.E.
1987-10-01
The neutral gas shielding model for ablation of frozen hydrogenic pellets is extended to include the effects of an initial Maxwelliam distribution of incident electron energies; a cold plasma shield outside the neutral shield and extended along the magnetic field; energetic neutral beam ions and alpha particles; and self-limiting electron ablation in the collisionless plasma limit. Including the full electron distribution increases ablation, but adding the cold ionized shield reduces ablation; the net effect is a modest reduction in pellet penetration compared with the monoenergetic electron neutral shielding model with no plasma shield. Unlike electrons, fast ions can enter the neutral shield directly without passing through the cold ionized shield because their gyro-orbits are typically larger than the diameter of the cold plasma tube. Fast alpha particles should not enhance the ablation rate unless their population exceeds that expected from local classical thermalization. Fast beam ions, however, may enhance ablation in the plasma periphery if their population is high enough. Self-limiting ablation in the collisionless limit leads to a temporary distortion of the original plasma electron Maxwellian distribution function through preferential depopulation of the higher-energy electrons. 23 refs., 9 figs
Tsuruta, Hisashi; Dondelewski, Oskar; Katagiri, Yusuke; Wang, Bin; Sasoh, Akihiro
2017-07-01
The ablation spot area and impulse characteristics of various polymers were experimentally investigated against burst irradiation of Nd: YLF laser pulses with a pulse repetition frequency of 1 kHz, wavelength of 1047 nm, temporal pulse width of 10 ns, and single-pulse fluence of 6.1 J/cm2 to 17.1 J/cm2. The dependences of ablation area on the pulse energy from 0.72 to 7.48 mJ and the number of pulses from 10 pulses to 1000 pulses were investigated. In order to characterize their impulse performance as a function of fluence, which should not depend on ablation material, an effective ablation spot area was defined as that obtained against aluminum, 1050 A, as the reference material. An impulse that resulted from a single burst of 200 pulses was measured with a torsion-type impulse stand. Various impulse dependences on the fluence, which were not readily predicted from the optical properties of the material without ablation, were obtained. By fitting the experimentally measured impulse performance to Phipps and Sinko's model in the vapor regime, the effective absorption coefficient with laser ablation was evaluated, thereby resulting in three to six orders of magnitude larger than that without ablation. Among the polymers examined using polytetrafluoroethylene (PTFE) as the best volume absorbers, the highest momentum coupling coefficient of 66 μNs/J was obtained with an effective absorption coefficient more than six times smaller than that of the other polymers.
Predicting Social Anxiety Treatment Outcome based on Therapeutic Email Conversations
Hoogendoorn, M.; Berger, Thomas; Schulz, Ava; Stolz, Timo; Szolovits, Peter
2016-01-01
Predicting therapeutic outcome in the mental health domain is of utmost importance to enable therapists to provide the most effective treatment to a patient. Using information from the writings of a patient can potentially be a valuable source of information, especially now that more and more
Modeling CO2 Laser Ablative Impulse with Polymers
International Nuclear Information System (INIS)
Sinko, John E.; Phipps, Claude R.; Sasoh, Akihiro
2010-01-01
Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO 2 laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO 2 laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.
Numerical simulation of Rayleigh-Taylor instability in ablation driven systems
International Nuclear Information System (INIS)
Verdon, C.P.
1984-01-01
Two-dimensional numerical simulations of ablatively accelerated thin shells subject to Rayleigh-Taylor instability are presented. Results for both single wavelength and multiwavelength perturbations show that the nonlinear effects of the instability are evident mainly in the bubble rather than the spike. Approximate roles for predicting the dominant nonlinear mode-mode interactions, which limit shell performance, are also discussed. The work concludes with a discussion of recommendations for future work in this area
A simple score to predict fetal outcomes in gestational diabetes mellitus
Directory of Open Access Journals (Sweden)
Kushal Naha
2015-04-01
Full Text Available Background: Strict glycemic control is critical in preventing adverse maternal and fetal outcomes with gestational diabetes mellitus (GDM, but frequently results in recurrent maternal hypoglycemia and is often impracticable. This study was done to determine whether a more lenient strategy might provide satisfactory outcomes and to formulate a glycemic score for prognostication of fetal outcomes. Methods: A prospective non-interventional study was conducted on consecutive patients admitted with GDM between May 2007 and August 2009. Patients with pre-gestational diabetes were excluded. All patients received treatment at the discretion of treating consultants. Glycemic control was estimated by recording mean values of all glucose profiles performed. Fasting and postprandial blood glucose levels below 95 mg/dl and 120 mg/dl, respectively, were considered controlled. A glycemic score was calculated based on the number of mean blood glucose values controlled. Fetal outcomes were noted. Results: Ninety-four patients with GDM were included. The glycemic score was significantly predictive of adverse fetal outcomes (p < 0.001. Analysis by receiver operating characteristic (ROC curve showed good sensitivity and specificity for macrosomia (78.3% and 81.8%, respectively and congenital anomalies (73.9% and 66.7%, respectively with a glycemic score of 2 or less [area under curve (AUC 0.768; odds ratio (OR, 11.17; 95% Confidence Interval (CI, 2.58-48.35; p < 0.001; and AUC 0.765; OR, 2.22; 95% CI, 0.71-6.92; p = 0.055, respectively]. Binomial logistic regression confirmed the glycemic score to be independently predictive of fetal outcome (p = 0.015. Conclusion: The glycemic score is a sensitive and specific prognostic marker. Tight control of three of four values of blood glucose within the glucose profile appears sufficient to prevent adverse fetal outcomes.
Wagle, Jørgen; Farner, Lasse; Flekkøy, Kjell; Bruun Wyller, Torgeir; Sandvik, Leiv; Fure, Brynjar; Stensrød, Brynhild; Engedal, Knut
2011-01-01
To identify prognostic factors associated with functional outcome at 13 months in a sample of stroke rehabilitation patients. Specifically, we hypothesized that cognitive functioning early after stroke would predict long-term functional outcome independently of other factors. 163 stroke rehabilitation patients underwent a structured neuropsychological examination 2-3 weeks after hospital admittance, and their functional status was subsequently evaluated 13 months later with the modified Rankin Scale (mRS) as outcome measure. Three predictive models were built using linear regression analyses: a biological model (sociodemographics, apolipoprotein E genotype, prestroke vascular factors, lesion characteristics and neurological stroke-related impairment); a functional model (pre- and early post-stroke cognitive functioning, personal and instrumental activities of daily living, ADL, and depressive symptoms), and a combined model (including significant variables, with p value Stroke Scale; β = 0.402, p stroke cognitive functioning (Repeatable Battery of Neuropsychological Status, RBANS; β = -0.248, p = 0.001) and prestroke personal ADL (Barthel Index; β = -0.217, p = 0.002). Further linear regression analyses of which RBANS indexes and subtests best predicted long-term functional outcome showed that Coding (β = -0.484, p stroke cognitive functioning as measured by the RBANS is a significant and independent predictor of long-term functional post-stroke outcome. Copyright © 2011 S. Karger AG, Basel.
Energy Technology Data Exchange (ETDEWEB)
Kim, Kang Pyo; Lee, Jeong Shim; Cho, Yeona; Chung, Seung Yeun; Lee, Jason Joon Bock; Lee, Chang Geol; Cho, Jae Ho [Dept. of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of)
2017-06-15
Although stereotactic ablative body radiotherapy (SABR) is widely used therapeutic technique, predictive factors of radiation pneumonitis (RP) after SABR remain undefined. We aimed to investigate the predictive factors affecting RP in patients with primary or metastatic lung tumors who received SABR. From 2012 to 2015, we reviewed 59 patients with 72 primary or metastatic lung tumors treated with SABR, and performed analyses of clinical and dosimetric variables related to symptomatic RP. SABR was delivered as 45–60 Gy in 3–4 fractions, which were over 100 Gy in BED when the α/β value was assumed to be 10. Tumor volume and other various dose volume factors were analyzed using median value as a cutoff value. RP was graded per the Common Terminology Criteria for Adverse Events v4.03. At the median follow-up period of 11 months, symptomatic RP was observed in 13 lesions (12 patients, 18.1%), including grade 2 RP in 11 lesions and grade 3 in 2 lesions. Patients with planning target volume (PTV) of ≤14.35 mL had significantly lower rates of symptomatic RP when compared to others (8.6% vs. 27%; p = 0.048). Rates of symptomatic RP in patients with internal gross tumor volume (iGTV) >4.21 mL were higher than with ≤4.21 mL (29.7% vs. 6.1%; p = 0.017). The incidence of symptomatic RP following treatment with SABR was acceptable with grade 2 RP being observed in most patients. iGTV over 4.21 mL and PTV of over 14.35 mL were significant predictive factors related to symptomatic RP.
Characterisation of tissue shrinkage during microwave thermal ablation.
Farina, Laura; Weiss, Noam; Nissenbaum, Yitzhak; Cavagnaro, Marta; Lopresto, Vanni; Pinto, Rosanna; Tosoratti, Nevio; Amabile, Claudio; Cassarino, Simone; Goldberg, S Nahum
2014-11-01
The aim of this study was to characterise changes in tissue volume during image-guided microwave ablation in order to arrive at a more precise determination of the true ablation zone. The effect of power (20-80 W) and time (1-10 min) on microwave-induced tissue contraction was experimentally evaluated in various-sized cubes of ex vivo liver (10-40 mm ± 2 mm) and muscle (20 and 40 mm ± 2 mm) embedded in agar phantoms (N = 119). Post-ablation linear and volumetric dimensions of the tissue cubes were measured and compared with pre-ablation dimensions. Subsequently, the process of tissue contraction was investigated dynamically during the ablation procedure through real-time X-ray CT scanning. Overall, substantial shrinkage of 52-74% of initial tissue volume was noted. The shrinkage was non-uniform over time and space, with observed asymmetry favouring the radial (23-43 % range) over the longitudinal (21-29%) direction. Algorithmic relationships for the shrinkage as a function of time were demonstrated. Furthermore, the smallest cubes showed more substantial and faster contraction (28-40% after 1 min), with more considerable volumetric shrinkage (>10%) in muscle than in liver tissue. Additionally, CT imaging demonstrated initial expansion of the tissue volume, lasting in some cases up to 3 min during the microwave ablation procedure, prior to the contraction phenomenon. In addition to an asymmetric substantial shrinkage of the ablated tissue volume, an initial expansion phenomenon occurs during MW ablation. Thus, complex modifications of the tissue close to a radiating antenna will likely need to be taken into account for future methods of real-time ablation monitoring.
PREDICTING THE MATCH OUTCOME IN ONE DAY INTERNATIONAL CRICKET MATCHES, WHILE THE GAME IS IN PROGRESS
Directory of Open Access Journals (Sweden)
Michael Bailey
2006-12-01
Full Text Available Millions of dollars are wagered on the outcome of one day international (ODI cricket matches, with a large percentage of bets occurring after the game has commenced. Using match information gathered from all 2200 ODI matches played prior to January 2005, a range of variables that could independently explain statistically significant proportions of variation associated with the predicted run totals and match outcomes were created. Such variables include home ground advantage, past performances, match experience, performance at the specific venue, performance against the specific opposition, experience at the specific venue and current form. Using a multiple linear regression model, prediction variables were numerically weighted according to statistical significance and used to predict the match outcome. With the use of the Duckworth-Lewis method to determine resources remaining, at the end of each completed over, the predicted run total of the batting team could be updated to provide a more accurate prediction of the match outcome. By applying this prediction approach to a holdout sample of matches, the efficiency of the "in the run" wagering market could be assessed. Preliminary results suggest that the market is prone to overreact to events occurring throughout the course of the match, thus creating brief inefficiencies in the wagering market
Kumar, Sumit; Sreenivas, Jayaram; Karthikeyan, Vilvapathy Senguttuvan; Mallya, Ashwin; Keshavamurthy, Ramaiah
2016-10-01
Scoring systems have been devised to predict outcomes of percutaneous nephrolithotomy (PCNL). CROES nephrolithometry nomogram (CNN) is the latest tool devised to predict stone-free rate (SFR). We aim to compare predictive accuracy of CNN against Guy stone score (GSS) for SFR and postoperative outcomes. Between January 2013 and December 2015, 313 patients undergoing PCNL were analyzed for predictive accuracy of GSS, CNN, and stone burden (SB) for SFR, complications, operation time (OT), and length of hospitalization (LOH). We further stratified patients into risk groups based on CNN and GSS. Mean ± standard deviation (SD) SB was 298.8 ± 235.75 mm 2 . SB, GSS, and CNN (area under curve [AUC]: 0.662, 0.660, 0.673) were found to be predictors of SFR. However, predictability for complications was not as good (AUC: SB 0.583, GSS 0.554, CNN 0.580). Single implicated calix (Adj. OR 3.644; p = 0.027), absence of staghorn calculus (Adj. OR 3.091; p = 0.044), single stone (Adj. OR 3.855; p = 0.002), and single puncture (Adj. OR 2.309; p = 0.048) significantly predicted SFR on multivariate analysis. Charlson comorbidity index (CCI; p = 0.020) and staghorn calculus (p = 0.002) were independent predictors for complications on linear regression. SB and GSS independently predicted OT on multivariate analysis. SB and complications significantly predicted LOH, while GSS and CNN did not predict LOH. CNN offered better risk stratification for residual stones than GSS. CNN and GSS have good preoperative predictive accuracy for SFR. Number of implicated calices may affect SFR, and CCI affects complications. Studies should incorporate these factors in scoring systems and assess if predictability of PCNL outcomes improves.
Microwave Tissue Ablation: Biophysics, Technology and Applications
2010-01-01
Microwave ablation is an emerging treatment option for many cancers, cardiac arrhythmias and other medical conditions. During treatment, microwaves are applied directly to tissues to produce rapid temperature elevations sufficient to produce immediate coagulative necrosis. The engineering design criteria for each application differ, with individual consideration for factors such as desired ablation zone size, treatment duration, and procedural invasiveness. Recent technological developments in applicator cooling, power control and system optimization for specific applications promise to increase the utilization of microwave ablation in the future. This article will review the basic biophysics of microwave tissue heating, provide an overview of the design and operation of current equipment, and outline areas for future research for microwave ablation. PMID:21175404
Cross-trial prediction of treatment outcome in depression: a machine learning approach.
Chekroud, Adam Mourad; Zotti, Ryan Joseph; Shehzad, Zarrar; Gueorguieva, Ralitza; Johnson, Marcia K; Trivedi, Madhukar H; Cannon, Tyrone D; Krystal, John Harrison; Corlett, Philip Robert
2016-03-01
Antidepressant treatment efficacy is low, but might be improved by matching patients to interventions. At present, clinicians have no empirically validated mechanisms to assess whether a patient with depression will respond to a specific antidepressant. We aimed to develop an algorithm to assess whether patients will achieve symptomatic remission from a 12-week course of citalopram. We used patient-reported data from patients with depression (n=4041, with 1949 completers) from level 1 of the Sequenced Treatment Alternatives to Relieve Depression (STAR*D; ClinicalTrials.gov, number NCT00021528) to identify variables that were most predictive of treatment outcome, and used these variables to train a machine-learning model to predict clinical remission. We externally validated the model in the escitalopram treatment group (n=151) of an independent clinical trial (Combining Medications to Enhance Depression Outcomes [COMED]; ClinicalTrials.gov, number NCT00590863). We identified 25 variables that were most predictive of treatment outcome from 164 patient-reportable variables, and used these to train the model. The model was internally cross-validated, and predicted outcomes in the STAR*D cohort with accuracy significantly above chance (64·6% [SD 3·2]; p<0·0001). The model was externally validated in the escitalopram treatment group (N=151) of COMED (accuracy 59·6%, p=0.043). The model also performed significantly above chance in a combined escitalopram-buproprion treatment group in COMED (n=134; accuracy 59·7%, p=0·023), but not in a combined venlafaxine-mirtazapine group (n=140; accuracy 51·4%, p=0·53), suggesting specificity of the model to underlying mechanisms. Building statistical models by mining existing clinical trial data can enable prospective identification of patients who are likely to respond to a specific antidepressant. Yale University. Copyright © 2016 Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Upadhyay, Arun K.; Inogamov, Nail A.; Rethfeld, Baerbel; Urbassek, Herbert M.
2008-01-01
Ultrafast laser irradiation of solids may ablate material off the surface. We study this process for thin films using molecular-dynamics simulation and thermodynamic analysis. Both metals and Lennard-Jones (LJ) materials are studied. We find that despite the large difference in thermodynamical properties between these two classes of materials--e.g., for aluminum versus LJ the ratio T c /T tr of critical to triple-point temperature differs by more than a factor of 4--the values of the ablation threshold energy E abl normalized to the cohesion energy, ε abl =E abl /E coh , are surprisingly universal: all are near 0.3 with ±30% scattering. The difference in the ratio T c /T tr means that for metals the melting threshold ε m is low, ε m abl , while for LJ it is high, ε m >ε abl . This thermodynamical consideration gives a simple explanation for the difference between metals and LJ. It explains why despite the universality in ε abl , metals thermomechanically ablate always from the liquid state. This is opposite to LJ materials, which (near threshold) ablate from the solid state. Furthermore, we find that immediately below the ablation threshold, the formation of large voids (cavitation) in the irradiated material leads to a strong temporary expansion on a very slow time scale. This feature is easily distinguished from the acoustic oscillations governing the material response at smaller intensities, on the one hand, and the ablation occurring at larger intensities, on the other hand. This finding allows us to explain the puzzle of huge surface excursions found in experiments at near-threshold laser irradiation
Lamberink, Herm J; Boshuisen, Kim; Otte, Willem M; Geleijns, Karin; Braun, Kees P J
2018-03-01
The objective of this study was to create a clinically useful tool for individualized prediction of seizure outcomes following antiepileptic drug withdrawal after pediatric epilepsy surgery. We used data from the European retrospective TimeToStop study, which included 766 children from 15 centers, to perform a proportional hazard regression analysis. The 2 outcome measures were seizure recurrence and seizure freedom in the last year of follow-up. Prognostic factors were identified through systematic review of the literature. The strongest predictors for each outcome were selected through backward selection, after which nomograms were created. The final models included 3 to 5 factors per model. Discrimination in terms of adjusted concordance statistic was 0.68 (95% confidence interval [CI] 0.67-0.69) for predicting seizure recurrence and 0.73 (95% CI 0.72-0.75) for predicting eventual seizure freedom. An online prediction tool is provided on www.epilepsypredictiontools.info/ttswithdrawal. The presented models can improve counseling of patients and parents regarding postoperative antiepileptic drug policies, by estimating individualized risks of seizure recurrence and eventual outcome. Wiley Periodicals, Inc. © 2018 International League Against Epilepsy.
Diao, Zongli; Wang, Liyan; Li, Dishan; Liu, Wenhu
2017-11-01
Severe secondary hyperparathyroidism (SHPT) is a serious problem in patients undergoing hemodialysis. The efficacy and safety of microwave ablation (MWA), a minimally invasive treatment, for severe SHPT are as yet unclear. To clarify the role of MWA, we administered it to patients with severe SHPT and assessed its efficacy and safety. This was a prospective, single-center, single-arm, clinical trial. We enrolled patients with severe SHPT attending our hemodialysis center who met the inclusion and exclusion criteria. We then assessed primary outcome measures (serum concentrations of intact parathyroid hormone) and secondary outcome measures (serum concentrations of calcium and phosphorus). Twenty-six patients were enrolled in this study, 10 of whom (38.46%) were responsive to MWA and 16 (61.54%) of whom were not. The main complication was hypocalcemia (10 cases, 38.46%), which had occurred in all cases by one week after administration of MWA. Responding patients with hypocalcemia all achieved normal serum calcium concentrations within seven months and non-responding patients within three months. There were no changes in serum phosphorus concentrations after MWA in either responders or non-responders. Microwave ablation is relatively ineffective in patients with severe SHPT undergoing maintaining hemodialysis and should not be the initial therapy in such cases.
Phipps, Claude
2007-01-01
Laser ablation describes the interaction of intense optical fields with matter, in which atoms are selectively driven off by thermal or nonthermal mechanisms. The field of laser ablation physics is advancing so rapidly that its principal results are seen only in specialized journals and conferences. This is the first book that combines the most recent results in this rapidly advancing field with authoritative treatment of laser ablation and its applications, including the physics of high-power laser-matter interaction. Many practical applications exist, ranging from inertial confinement fusion to propulsion of aerostats for pollution monitoring to laser ignition of hypersonic engines to laser cleaning nanoscale contaminants in high-volume computer hard drive manufacture to direct observation of the electronic or dissociative states in atoms and molecules, to studying the properties of materials during 200kbar shocks developed in 200fs. Selecting topics which are representative of such a broad field is difficu...
Boyd, Roslyn N; Davies, Peter Sw; Ziviani, Jenny; Trost, Stewart; Barber, Lee; Ware, Robert; Rose, Stephen; Whittingham, Koa; Sakzewski, Leanne; Bell, Kristie; Carty, Christopher; Obst, Steven; Benfer, Katherine; Reedman, Sarah; Edwards, Priya; Kentish, Megan; Copeland, Lisa; Weir, Kelly; Davenport, Camilla; Brooks, Denise; Coulthard, Alan; Pelekanos, Rebecca; Guzzetta, Andrea; Fiori, Simona; Wynter, Meredith; Finn, Christine; Burgess, Andrea; Morris, Kym; Walsh, John; Lloyd, Owen; Whitty, Jennifer A; Scuffham, Paul A
2017-07-12
Cerebral palsy (CP) remains the world's most common childhood physical disability with total annual costs of care and lost well-being of $A3.87b. The PREDICT-CP (NHMRC 1077257 Partnership Project: Comprehensive surveillance to PREDICT outcomes for school age children with CP) study will investigate the influence of brain structure, body composition, dietary intake, oropharyngeal function, habitual physical activity, musculoskeletal development (hip status, bone health) and muscle performance on motor attainment, cognition, executive function, communication, participation, quality of life and related health resource use costs. The PREDICT-CP cohort provides further follow-up at 8-12 years of two overlapping preschool-age cohorts examined from 1.5 to 5 years (NHMRC 465128 motor and brain development; NHMRC 569605 growth, nutrition and physical activity). This population-based cohort study undertakes state-wide surveillance of 245 children with CP born in Queensland (birth years 2006-2009). Children will be classified for Gross Motor Function Classification System; Manual Ability Classification System, Communication Function Classification System and Eating and Drinking Ability Classification System. Outcomes include gross motor function, musculoskeletal development (hip displacement, spasticity, muscle contracture), upper limb function, communication difficulties, oropharyngeal dysphagia, dietary intake and body composition, participation, parent-reported and child-reported quality of life and medical and allied health resource use. These detailed phenotypical data will be compared with brain macrostructure and microstructure using 3 Tesla MRI (3T MRI). Relationships between brain lesion severity and outcomes will be analysed using multilevel mixed-effects models. The PREDICT-CP protocol is a prospectively registered and ethically accepted study protocol. The study combines data at 1.5-5 then 8-12 years of direct clinical assessment to enable prediction of outcomes
Directory of Open Access Journals (Sweden)
Ali M. El Saman
2015-01-01
Full Text Available Objective. To study the efficacy and safety of tactile electrosurgical ablation (TEA in stopping a persistent attack of abnormal uterine bleeding not responding to medical and hormonal therapy. Methods. This is a case series of 19 cases with intractable abnormal uterine bleeding, who underwent TEA at the Women’s Health Center of Assiut University. The outcomes measured were; patient’s acceptability, operative time, complications, menstrual outcomes, and reintervention. Results. None of the 19 counseled cases refused the TEA procedure which took 6–10 minutes without intraoperative complications. The procedure was successful in the immediate cessation of bleeding in 18 out of 19 cases. During the 24-month follow-up period, 9 cases developed amenorrhea, 5 had scanty menstrual bleeding, 3 were regularly menstruating, 1 case underwent repeat TEA ablation, and one underwent a hysterectomy. Conclusions. TEA represents a safe, inexpensive, and successful method for management of uterine bleeding emergencies with additional long-term beneficial effects. However, more studies with more cases and longer follow-up periods are warranted.
Energy Technology Data Exchange (ETDEWEB)
Vroomen, Laurien G.P.H.; Scheffer, Hester J.; Melenhorst, Marleen C.A.M.; Jong, Marcus C. de; Bergh, Janneke E. van den; Kuijk, Cornelis van; Meijerink, Martijn R. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Delft, Foke van [VU University Medical Center, Department of Gastroenterology and Hepatology, Amsterdam (Netherlands); Kazemier, Geert [VU University Medical Center, Department of Surgery, Amsterdam (Netherlands)
2017-06-15
To assess specific imaging characteristics after irreversible electroporation (IRE) for locally advanced pancreatic carcinoma (LAPC) with contrast-enhanced (ce)MRI and ceCT, and to explore the correlation of these characteristics with the development of recurrence. Qualitative and quantitative analyses of imaging data were performed on 25 patients treated with percutaneous IRE for LAPC. Imaging characteristics of the ablation zone on ceCT and ceMRI were assessed over a 6-month follow-up period. Contrast ratio scores between pre- and post-treatment were compared. To detect early imaging markers for treatment failure, attenuation characteristics at 6 weeks were linked to the area of recurrence within 6 months. Post-IRE, diffusion-weighted imaging (DWI)-b800 signal intensities decreased in all cases (p < 0.05). Both ceMRI and ceCT revealed absent or decreased contrast enhancement, with a hyperintense rim on ceMRI. Ablation zone volume increase was noted on both modalities in the first 6 weeks, followed by a decrease (p < 0.05). In the patients developing tumour recurrence (5/25), a focal DWI-b800 hyperintense spot at 6 weeks predated unequivocal recurrence on CT. The most remarkable signal alterations after pancreatic IRE were shown by DWI-b800 and ceMRI. These early imaging characteristics may be useful to establish technical success and predict treatment outcome. (orig.)
Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review
Directory of Open Access Journals (Sweden)
Paraskevi Vogiatzi
2013-01-01
Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.
Magnetic resonance imaging of injuries to the ankle joint: can it predict clinical outcome?
Zanetti, M; De Simoni, C; Wetz, H H; Zollinger, H; Hodler, J
1997-02-01
To predict clinical outcome after ankle sprains on the basis of magnetic resonance (MR) findings. Twenty-nine consecutive patients (mean age 32.9 years, range 13-60 years) were examined clinically and with MR imaging both after trauma and following standardized conservative therapy. Various MR abnormalities were related to a clinical outcome score. There was a tendency for a better clinical outcome in partial, rather than complete, tears of the anterior talofibular ligament and when there was no fluid within the peroneal tendon sheath at the initial MR examination (P = 0.092 for either abnormality). A number of other MR features did not significantly influence clinical outcome, including the presence of a calcaneofibular ligament lesion and a bone bruise of the talar dome. Clinical outcome after ankle sprain cannot consistently be predicted by MR imaging, although MR imaging may be more accurate when the anterior talofibular ligament is only partially torn and there are no signs of injury to the peroneal tendon sheath.
Verwoerd, A J H; Luijsterburg, P A J; Lin, C W C; Jacobs, W C H; Koes, B W; Verhagen, A P
2013-09-01
Identification of prognostic factors for surgery in patients with sciatica is important to be able to predict surgery in an early stage. Identification of prognostic factors predicting persistent pain, disability and recovery are important for better understanding of the clinical course, to inform patient and physician and support decision making. Consequently, we aimed to systematically review prognostic factors predicting outcome in non-surgically treated patients with sciatica. A search of Medline, Embase, Web of Science and Cinahl, up to March 2012 was performed for prospective cohort studies on prognostic factors for non-surgically treated sciatica. Two reviewers independently selected studies for inclusion and assessed the risk of bias. Outcomes were pain, disability, recovery and surgery. A best evidence synthesis was carried out in order to assess and summarize the data. The initial search yielded 4392 articles of which 23 articles reporting on 14 original cohorts met the inclusion criteria. High clinical, methodological and statistical heterogeneity among studies was found. Reported evidence regarding prognostic factors predicting the outcome in sciatica is limited. The majority of factors that have been evaluated, e.g., age, body mass index, smoking and sensory disturbance, showed no association with outcome. The only positive association with strong evidence was found for leg pain intensity at baseline as prognostic factor for subsequent surgery. © 2013 European Federation of International Association for the Study of Pain Chapters.
Stefan, Sabina; Schorr, Barbara; Lopez-Rolon, Alex; Kolassa, Iris-Tatjana; Shock, Jonathan P; Rosenfelder, Martin; Heck, Suzette; Bender, Andreas
2018-04-17
We applied the following methods to resting-state EEG data from patients with disorders of consciousness (DOC) for consciousness indexing and outcome prediction: microstates, entropy (i.e. approximate, permutation), power in alpha and delta frequency bands, and connectivity (i.e. weighted symbolic mutual information, symbolic transfer entropy, complex network analysis). Patients with unresponsive wakefulness syndrome (UWS) and patients in a minimally conscious state (MCS) were classified into these two categories by fitting and testing a generalised linear model. We aimed subsequently to develop an automated system for outcome prediction in severe DOC by selecting an optimal subset of features using sequential floating forward selection (SFFS). The two outcome categories were defined as UWS or dead, and MCS or emerged from MCS. Percentage of time spent in microstate D in the alpha frequency band performed best at distinguishing MCS from UWS patients. The average clustering coefficient obtained from thresholding beta coherence performed best at predicting outcome. The optimal subset of features selected with SFFS consisted of the frequency of microstate A in the 2-20 Hz frequency band, path length obtained from thresholding alpha coherence, and average path length obtained from thresholding alpha coherence. Combining these features seemed to afford high prediction power. Python and MATLAB toolboxes for the above calculations are freely available under the GNU public license for non-commercial use ( https://qeeg.wordpress.com ).
2015-10-01
FORD CLASS AIRCRAFT CARRIER Poor Outcomes Are the Predictable Consequences of the Prevalent Acquisition Culture...2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE Ford Class Aircraft Carrier: Poor Outcomes Are the Predictable...This Study The Navy set ambitious goals for the Ford -class program, including an array of new technologies and design features that were intended
Directory of Open Access Journals (Sweden)
Ju-Yeon Cho
2016-12-01
Full Text Available Background/Aims Radiofrequency ablation (RFA is one of the most frequently applied curative treatments in patients with a single small hepatocellular carcinoma (HCC. However, the clinical significance of and risk factors for early massive recurrence after RFA—a dreadful event limiting further curative treatment—have not been fully evaluated. Methods In total, 438 patients with a single HCC of size ≤3 cm who underwent percutaneous RFA as an initial treatment between 2006 and 2009 were included. Baseline patient characteristics, overall survival, predictive factors, and recurrence after RFA were evaluated. In addition, the incidence, impact on survival, and predictive factors of early massive recurrence, and initial recurrence beyond the Milan criteria within 2 years were also investigated. Results During the median follow-up of 68.4 months, recurrent HCC was confirmed in 302 (68.9% patients, with early massive recurrence in 27 patients (6.2%. The 1-, 3-, and 5-year overall survival rates were 95.4%, 84.7%, and 81.8%, respectively, in patients with no recurrence, 99.6%, 86.4%, and 70.1% in patients with recurrence within the Milan criteria or late recurrence, and 92.6%, 46.5%, and 0.05% in patients with early massive recurrence. Multivariable analysis identified older age, Child-Pugh score B or C, and early massive recurrence as predictive of poor overall survival. A tumor size of ≥2 cm and tumor location adjacent to the colon were independent risk factors predictive of early massive recurrence. Conclusions Early massive recurrence is independently predictive of poor overall survival after RFA in patients with a single small HCC. Tumors sized ≥2 cm and located adjacent to the colon appear to be independent risk factors for early massive recurrence.
TEM investigations of laser ablated particles
International Nuclear Information System (INIS)
Fliegel, D.; Dundas, S.; Kosler, J.; Klementova, M.
2009-01-01
Full text: Laser ablation inductively coupled plasma mass spectrometry suffers from fractionation effects hindering a non matrix matched calibration strategy. Different reasons for elemental fractionation that are related to the laser ablation, the transport and the vaporization in the plasma are discussed. One major question to be addressed linked to the vaporization yield in the ICP is in which of mineralogical phase the different ablated particle sizes enter the plasma. This contribution will investigate particles generated by a 213 nm laser from different samples such as minerals and alloys with respect to their chemical and phase compositions using high resolution TEM. (author)
Pacemaker implantation after catheter ablation for atrial fibrillation.
Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A
2016-01-01
Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.
Actual role of radiofrequency ablation of liver metastases
Energy Technology Data Exchange (ETDEWEB)
Pereira, Philippe L. [Eberhard-Karls-University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany)
2007-08-15
The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)
Actual role of radiofrequency ablation of liver metastases
International Nuclear Information System (INIS)
Pereira, Philippe L.
2007-01-01
The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)
Plume collimation for laser ablation electrospray ionization mass spectrometry
Vertes, Akos; Stolee, Jessica A.
2014-09-09
In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.
Directory of Open Access Journals (Sweden)
Cecilie Røe
2015-01-01
Full Text Available The aim of the present study was to evaluate mortality and functional outcome in old and very old patients with severe traumatic brain injury (TBI and compare to the predicted outcome according to the internet based CRASH (Corticosteroid Randomization After Significant Head injury model based prediction, from the Medical Research Council (MRC. Methods. Prospective, national multicenter study including patients with severe TBI ≥65 years. Predicted mortality and outcome were calculated based on clinical information (CRASH basic (age, GCS score, and pupil reactivity to light, as well as with additional CT findings (CRASH CT. Observed 14-day mortality and favorable/unfavorable outcome according to the Glasgow Outcome Scale at one year was compared to the predicted outcome according to the CRASH models. Results. 97 patients, mean age 75 (SD 7 years, 64% men, were included. Two patients were lost to follow-up; 48 died within 14 days. The predicted versus the observed odds ratio (OR for mortality was 2.65. Unfavorable outcome (GOSE < 5 was observed at one year follow-up in 72% of patients. The CRASH models predicted unfavorable outcome in all patients. Conclusion. The CRASH model overestimated mortality and unfavorable outcome in old and very old Norwegian patients with severe TBI.
Røe, Cecilie; Skandsen, Toril; Manskow, Unn; Ader, Tiina; Anke, Audny
2015-01-01
The aim of the present study was to evaluate mortality and functional outcome in old and very old patients with severe traumatic brain injury (TBI) and compare to the predicted outcome according to the internet based CRASH (Corticosteroid Randomization After Significant Head injury) model based prediction, from the Medical Research Council (MRC). Methods. Prospective, national multicenter study including patients with severe TBI ≥65 years. Predicted mortality and outcome were calculated based on clinical information (CRASH basic) (age, GCS score, and pupil reactivity to light), as well as with additional CT findings (CRASH CT). Observed 14-day mortality and favorable/unfavorable outcome according to the Glasgow Outcome Scale at one year was compared to the predicted outcome according to the CRASH models. Results. 97 patients, mean age 75 (SD 7) years, 64% men, were included. Two patients were lost to follow-up; 48 died within 14 days. The predicted versus the observed odds ratio (OR) for mortality was 2.65. Unfavorable outcome (GOSE < 5) was observed at one year follow-up in 72% of patients. The CRASH models predicted unfavorable outcome in all patients. Conclusion. The CRASH model overestimated mortality and unfavorable outcome in old and very old Norwegian patients with severe TBI. PMID:26688614
Percutaneous thermal ablation of renal neoplasms; Perkutane Thermoablation von Nierentumoren
Energy Technology Data Exchange (ETDEWEB)
Tacke, J. [Inst. fuer Diagnostische und Interventionelle Radiologie/Neuroradiologie, Klinikum Passau (Germany); Mahnken, A.H.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum Aachen (Germany)
2005-12-15
Due to modern examination techniques such as multidetector computed tomography and high-field magnetic resonance imaging, the detection rate of renal neoplasms is continually increasing. Even though tumors exceeding 4 cm in diameter rarely metastasize, all renal lesions that are possible neoplasms should be treated. Traditional treatment techniques include radical nephrectomy or nephron-sparing resection, which are increasingly performed laparoscopically. Modern thermal ablation techniques such as hyperthermal techniques like radiofrequency ablation RFA, laser induced thermal ablation LITT, focused ultrasound FUS and microwave therapy MW, as well as hypothermal techniques (cryotherapy) may be a useful treatment option for patients who are unfit for or refuse surgical resection. Cryotherapy is the oldest and best known thermal ablation technique and can be performed laparoscopically or percutaneously. Since subzero temperatures have no antistyptic effect, additional maneuvers must be performed to control bleeding. Percutaneous cryotherapy of renal tumors is a new and interesting method, but experience with it is still limited. Radiofrequency ablation is the most frequently used method. Modern probe design allows volumes between 2 and 5 cm in diameter to be ablated. Due to hyperthermal tract ablation, the procedure is deemed to be safe and has a low complication rate. Although there are no randomized comparative studies to open resection, the preliminary results for renal RFA are promising and show RFA to be superior to other thermal ablation techniques. Clinical success rates are over 90% for both, cryo- and radiofrequency ablation. Whereas laser induced thermal therapy is established in hepatic ablation, experience is minimal with respect to renal application. For lesions of more than 2 cm in diameter, additional cooling catheters are required. MR thermometry offers temperature control during ablation. Microwave ablation is characterized by small ablation volumes
Scholtz, Samantha; Bidlake, Louise; Morgan, John; Fiennes, Alberic; El-Etar, Ashraf; Lacey, John Hubert; McCluskey, Sara
2007-09-01
NICE guidelines state that patients with psychological contra-indications should not be considered for bariatric surgery, including Laparoscopic Adjustable Gastric Banding (LAGB) surgery as treatment of morbid obesity, although no consistent correlation between psychiatric illness and long-term outcome in LAGB has been established. This is to our knowledge the first study to evaluate long-term outcomes in LAGB for a full range of DSM-IV defined psychiatric and eating disorders, and forms part of a research portfolio developed by the authors aimed at defining psychological predictors of bariatric surgery in the short-, medium- and long-term. Case notes of 37 subjects operated on between April 1997 and June 2000, who had undergone structured clinical interview during pre-surgical assessment to yield diagnoses of mental and eating disorders according to DSM-IV criteria were analyzed according to a set of operationally defined criteria. Statistical analysis was carried out to compare those with a poor outcome and those considered to have a good outcome in terms of psychiatric profile. In this group of mainly female, Caucasian subjects, ranging in age from 27 to 60 years, one-third were diagnosed with a mental disorder according to DSM-IV criteria. The development of postoperative DSM-IV defined binge eating disorder (BED) or depression strongly predicted poor surgical outcome, but pre-surgical psychiatric factors alone did not. Although pre-surgical psychiatric assessment alone cannot predict outcome, an absence of preoperative psychiatric illness should not reassure surgeons who should be mindful of postoperative psychiatric sequelae, particularly BED. The importance of providing an integrated biopsychosocial model of care in bariatric teams is highlighted.
Fronto-Temporal Connectivity Predicts ECT Outcome in Major Depression
Directory of Open Access Journals (Sweden)
Amber M. Leaver
2018-03-01
Full Text Available BackgroundElectroconvulsive therapy (ECT is arguably the most effective available treatment for severe depression. Recent studies have used MRI data to predict clinical outcome to ECT and other antidepressant therapies. One challenge facing such studies is selecting from among the many available metrics, which characterize complementary and sometimes non-overlapping aspects of brain function and connectomics. Here, we assessed the ability of aggregated, functional MRI metrics of basal brain activity and connectivity to predict antidepressant response to ECT using machine learning.MethodsA radial support vector machine was trained using arterial spin labeling (ASL and blood-oxygen-level-dependent (BOLD functional magnetic resonance imaging (fMRI metrics from n = 46 (26 female, mean age 42 depressed patients prior to ECT (majority right-unilateral stimulation. Image preprocessing was applied using standard procedures, and metrics included cerebral blood flow in ASL, and regional homogeneity, fractional amplitude of low-frequency modulations, and graph theory metrics (strength, local efficiency, and clustering in BOLD data. A 5-repeated 5-fold cross-validation procedure with nested feature-selection validated model performance. Linear regressions were applied post hoc to aid interpretation of discriminative features.ResultsThe range of balanced accuracy in models performing statistically above chance was 58–68%. Here, prediction of non-responders was slightly higher than for responders (maximum performance 74 and 64%, respectively. Several features were consistently selected across cross-validation folds, mostly within frontal and temporal regions. Among these were connectivity strength among: a fronto-parietal network [including left dorsolateral prefrontal cortex (DLPFC], motor and temporal networks (near ECT electrodes, and/or subgenual anterior cingulate cortex (sgACC.ConclusionOur data indicate that pattern classification of multimodal f
Avoiding Complications in Bone and Soft Tissue Ablation
International Nuclear Information System (INIS)
Kurup, A. Nicholas; Schmit, Grant D.; Morris, Jonathan M.; Atwell, Thomas D.; Schmitz, John J.; Weisbrod, Adam J.; Woodrum, David A.; Eiken, Patrick W.; Callstrom, Matthew R.
2017-01-01
As with percutaneous ablation of tumors in the liver, lungs, and kidneys, ablation of bone and non-visceral soft tissue tumors carries risk, primarily from collateral damage to vital structures in proximity to the target tumor. Certain risks are of particular interest when ablating bone and non-visceral soft tissue tumors, namely neural or skin injury, bowel injury, fracture, and gas embolism from damaged applicators. Ablation of large volume tumors also carries special risk. Many techniques may be employed by the interventional radiologist to minimize complications when treating tumors in the musculoskeletal system. These methods include those to depict, displace, or monitor critical structures. Thus, measures to provide thermoprotection may be active, such as careful ablation applicator placement and use of various displacement techniques, as well as passive, including employment of direct temperature, radiographic, or neurophysiologic monitoring techniques. Cementoplasty should be considered in certain skeletal locations at risk of fracture. Patients treated with large volume tumors should be monitored for renal dysfunction and properly hydrated. Finally, ablation applicators should be cautiously placed in the constrained environment of intact bone.
Avoiding Complications in Bone and Soft Tissue Ablation
Energy Technology Data Exchange (ETDEWEB)
Kurup, A. Nicholas, E-mail: kurup.anil@mayo.edu; Schmit, Grant D., E-mail: schmit.grant@mayo.edu; Morris, Jonathan M., E-mail: morris.jonathan@mayo.edu; Atwell, Thomas D., E-mail: atwell.thomas@mayo.edu; Schmitz, John J., E-mail: schmitz.john@mayo.edu; Weisbrod, Adam J., E-mail: weisbrod.adam@mayo.edu; Woodrum, David A., E-mail: woodrum.david@mayo.edu; Eiken, Patrick W., E-mail: eiken.patrick@mayo.edu; Callstrom, Matthew R., E-mail: callstrom.matthew@mayo.edu [Mayo Clinic, Department of Radiology (United States)
2017-02-15
As with percutaneous ablation of tumors in the liver, lungs, and kidneys, ablation of bone and non-visceral soft tissue tumors carries risk, primarily from collateral damage to vital structures in proximity to the target tumor. Certain risks are of particular interest when ablating bone and non-visceral soft tissue tumors, namely neural or skin injury, bowel injury, fracture, and gas embolism from damaged applicators. Ablation of large volume tumors also carries special risk. Many techniques may be employed by the interventional radiologist to minimize complications when treating tumors in the musculoskeletal system. These methods include those to depict, displace, or monitor critical structures. Thus, measures to provide thermoprotection may be active, such as careful ablation applicator placement and use of various displacement techniques, as well as passive, including employment of direct temperature, radiographic, or neurophysiologic monitoring techniques. Cementoplasty should be considered in certain skeletal locations at risk of fracture. Patients treated with large volume tumors should be monitored for renal dysfunction and properly hydrated. Finally, ablation applicators should be cautiously placed in the constrained environment of intact bone.
Khan, Habib Rehman; Kralj-Hans, Ines; Haldar, Shouvik; Bahrami, Toufan; Clague, Jonathan; De Souza, Anthony; Francis, Darrel; Hussain, Wajid; Jarman, Julian; Jones, David Gareth; Mediratta, Neeraj; Mohiaddin, Raad; Salukhe, Tushar; Jones, Simon; Lord, Joanne; Murphy, Caroline; Kelly, Joanna; Markides, Vias; Gupta, Dhiraj; Wong, Tom
2018-02-20
Atrial fibrillation is the commonest arrhythmia which raises the risk of heart failure, thromboembolic stroke, morbidity and death. Pharmacological treatments of this condition are focused on heart rate control, rhythm control and reduction in risk of stroke. Selective ablation of cardiac tissues resulting in isolation of areas causing atrial fibrillation is another treatment strategy which can be delivered by two minimally invasive interventions: percutaneous catheter ablation and thoracoscopic surgical ablation. The main purpose of this trial is to compare the effectiveness and safety of these two interventions. Catheter Ablation versus Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation (CASA-AF) is a prospective, multi-centre, randomised controlled trial within three NHS tertiary cardiovascular centres specialising in treatment of atrial fibrillation. Eligible adults (n = 120) with symptomatic, long-standing, persistent atrial fibrillation will be randomly allocated to either catheter ablation or thoracoscopic ablation in a 1:1 ratio. Pre-determined lesion sets will be delivered in each treatment arm with confirmation of appropriate conduction block. All patients will have an implantable loop recorder (ILR) inserted subcutaneously immediately following ablation to enable continuous heart rhythm monitoring for at least 12 months. The devices will be programmed to detect episodes of atrial fibrillation and atrial tachycardia ≥ 30 s in duration. The patients will be followed for 12 months, completing appropriate clinical assessments and questionnaires every 3 months. The ILR data will be wirelessly transmitted daily and evaluated every month for the duration of the follow-up. The primary endpoint in the study is freedom from atrial fibrillation and atrial tachycardia at the end of the follow-up period. The CASA-AF Trial is a National Institute for Health Research-funded study that will provide first-class evidence on the
Microwave ablation devices for interventional oncology.
Ward, Robert C; Healey, Terrance T; Dupuy, Damian E
2013-03-01
Microwave ablation is one of the several options in the ablation armamentarium for the treatment of malignancy, offering several potential benefits when compared with other ablation, radiation, surgical and medical treatment modalities. The basic microwave system consists of the generator, power distribution system and antennas. Often under image (computed tomography or ultrasound) guidance, a needle-like antenna is inserted percutaneously into the tumor, where local microwave electromagnetic radiation is emitted from the probe's active tip, producing frictional tissue heating, capable of causing cell death by coagulation necrosis. Half of the microwave ablation systems use a 915 MHz generator and the other half use a 2450 MHz generator. To date, there are no completed clinical trials comparing microwave devices head-to-head. Prospective comparisons of microwave technology with other treatment alternatives, as well as head-to-head comparison with each microwave device, is needed if this promising field will garner more widespread support and use in the oncology community.
Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.
Soucek, Filip; Starek, Zdenek
2018-05-23
Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Directory of Open Access Journals (Sweden)
Shuhua Ma
2016-01-01
Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.
Facelift combined with simultaneous fractional laser resurfacing: Outcomes and complications.
Wright, Eric J; Struck, Steve K
2015-10-01
The combination of simultaneous surgical rhytidectomy with ablative resurfacing has been a controversial procedure due to the concern of postoperative wound healing. Traditional ablative resurfacing lasers are believed to have higher rates of complications, leading to delayed healing and skin flap loss when combined with face rhytidectomy surgeries. With the development of fractionated ablative laser therapy, there has been increased interest in combining these two procedures. The objective of this study is to evaluate the clinical outcomes of patients undergoing simultaneous full-face rhytidectomy in combination with fractionated ablative skin resurfacing. A retrospective chart analysis was performed for all patients who had a combined procedure of facelift and ablative fractional laser resurfacing from 2008 to 2013 by the senior author (SKS). Postoperative recovery and complications were recorded. The surgical technique used for performing the facelift was an extended supraplatysmal dissection with SMAS plication. Fraxel Re:Pair 10,600-nm fractional carbon dioxide laser was used to perform an ablative resurfacing including the elevated skin flaps. A total of 86 patients were included. Average age was 60.01 years (range of 45-78 years). Longest follow up was five years. The average size of the elevated skin flaps was 100 cm(2). Average skin type was a Fitzpatrick type 2. All patients had complete re-epithelialization by one week after their procedure. Four patients (4.6%) experienced acne outbreaks. Four patients (4.6%) had facial erythema that persisted greater than two weeks. Of these four patients, all resolved by five weeks postoperatively. There was no delayed wound healing or skin flap loss observed. Our results indicate that simultaneous rhytidectomy with fractionated ablative laser resurfacing does not cause an increase in wound healing or skin loss. Due to improved patient outcomes with combining these procedures, we believe that this can be increasingly
International Nuclear Information System (INIS)
Jensen, C R; Cleveland, R O; Coussios, C C
2013-01-01
Passive acoustic mapping (PAM) has been recently demonstrated as a method of monitoring focused ultrasound therapy by reconstructing the emissions created by inertially cavitating bubbles (Jensen et al 2012 Radiology 262 252–61). The published method sums energy emitted by cavitation from the focal region within the tissue and uses a threshold to determine when sufficient energy has been delivered for ablation. The present work builds on this approach to provide a high-intensity focused ultrasound (HIFU) treatment monitoring software that displays both real-time temperature maps and a prediction of the ablated tissue region. This is achieved by determining heat deposition from two sources: (i) acoustic absorption of the primary HIFU beam which is calculated via a nonlinear model, and (ii) absorption of energy from bubble acoustic emissions which is estimated from measurements. The two sources of heat are used as inputs to the bioheat equation that gives an estimate of the temperature of the tissue as well as estimates of tissue ablation. The method has been applied to ex vivo ox liver samples and the estimated temperature is compared to the measured temperature and shows good agreement, capturing the effect of cavitation-enhanced heating on temperature evolution. In conclusion, it is demonstrated that by using PAM and predictions of heating it is possible to produce an evolving estimate of cell death during exposure in order to guide treatment for monitoring ablative HIFU therapy. (paper)
International Nuclear Information System (INIS)
Lepetit-Coiffe, Matthieu; Quesson, Bruno; Moonen, Chrit T.W.; Laumonier, Herve; Trillaud, Herve; Seror, Olivier; Sesay, Musa-Bahazid; Grenier, Nicolas
2010-01-01
To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas and one colorectal metastasis), were treated by 12-min RF ablation using a 1.5-T closed magnet for real-time temperature monitoring. The clinical monopolar RF device was filtered at 64 MHz to avoid electromagnetic interference. Real-time computation of thermal-dose (TD) maps, based on Sapareto and Dewey's equation, was studied to determine its ability to provide a clear end-point of the RF procedure. Absence of local recurrence on follow-up MR images obtained 45 days after the RF ablation was used to assess the apoptotic and necrotic prediction obtained by real-time TD maps. Seven out of nine tumours were completely ablated according to the real-time TD maps. Compared with 45-day follow-up MR images, TD maps accurately predicted two primary treatment failures, but were not relevant in the later progression of one case of secondary local tumour. The real-time TD concept is a feasible and promising monitoring method for the RF ablation of liver tumours. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Lepetit-Coiffe, Matthieu; Quesson, Bruno; Moonen, Chrit T.W. [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Laumonier, Herve; Trillaud, Herve [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service de Radiologie, Hopital Saint-Andre, CHU Bordeaux, Bordeaux (France); Seror, Olivier [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service de Radiologie, Hopital Jean Verdier, Bondy (France); Sesay, Musa-Bahazid [Service d' Anesthesie Reanimation III, Hopital Pellegrin, CHU Bordeaux, Bordeaux (France); Grenier, Nicolas [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service d' Imagerie Diagnostique et Therapeutique de l' Adulte, Hopital Pellegrin, CHU Bordeaux, Bordeaux (France)
2010-01-15
To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas and one colorectal metastasis), were treated by 12-min RF ablation using a 1.5-T closed magnet for real-time temperature monitoring. The clinical monopolar RF device was filtered at 64 MHz to avoid electromagnetic interference. Real-time computation of thermal-dose (TD) maps, based on Sapareto and Dewey's equation, was studied to determine its ability to provide a clear end-point of the RF procedure. Absence of local recurrence on follow-up MR images obtained 45 days after the RF ablation was used to assess the apoptotic and necrotic prediction obtained by real-time TD maps. Seven out of nine tumours were completely ablated according to the real-time TD maps. Compared with 45-day follow-up MR images, TD maps accurately predicted two primary treatment failures, but were not relevant in the later progression of one case of secondary local tumour. The real-time TD concept is a feasible and promising monitoring method for the RF ablation of liver tumours. (orig.)
International Nuclear Information System (INIS)
Gupta, N.K.
2002-01-01
The effects of radiation transport on hydrodynamic parameters of laser produced plasmas are studied. LTE and non-LTE atomic models are used to calculate multi group opacities and emissivities. Screened hydrogenic atom model is used to calculate the energy levels. The population densities of neutral to fully ionized ions are obtained by solving the steady state rate equations. Radiation transport is treated in multi-group diffusion or Sn method. A comparison is made between 1 and 100 group radiation transport and LTE and non-LTE models. For aluminium, multi group radiation transport leads to much higher mass ablation as compared to the 1 group and no radiation transport cases. This in turn leads to higher ablation pressures. However, for gold gray approximation gives higher mass ablation as compared to multi group simulations. LTE conversion efficiency of laser light into x-rays is more than the non-LTE estimates. For LTE as well as non-LTE cases, the one group approximation over-predicts the conversion efficiency Multi group non-LTE simulations predict that the conversion efficiency increases with laser intensity up to a maximum and then it decreases. (author)