WorldWideScience

Sample records for aberrant subclavian artery

  1. Right cervical aortic arch with aberrant left subclavian artery.

    Science.gov (United States)

    Tjang, Yanto S; Aramendi, José I; Crespo, Alejandro; Hamzeh, Gadah; Voces, Roberto; Rodríguez, Miguel A

    2008-08-01

    The combination of right cervical aortic arch, aberrant retroesophageal left subclavian artery originating from a Kommerell's diverticulum, and a ligamentum arteriosum, constitutes a rare form of vascular ring. Two patients aged 21 days and 54 years, who were diagnosed by multislice 3-dimensional computed tomography and magnetic resonance imaging, underwent surgical division of a vascular ring. The adult required resection of a Kommerell's aneurysm and subclavian artery reimplantation.

  2. Aberrant right subclavian artery causing megaoesophagus in three cats.

    Science.gov (United States)

    Cinti, F; Della Santa, D; Borgonovo, S; Bussadori, R; Troiano, D; Pisani, G

    2018-05-07

    Three entire, domestic, shorthair male cats (age range: 3 months to 5 years) were referred because of regurgitation. Megaoesophagus attributable to aberrant right subclavian artery, originating from the aorta at the level of the fourth intercostal space, was diagnosed in all cats using thoracic radiography and CT angiography. One cat had concurrent patent ductus arteriosus with a normal aortic arch. Three-dimensional volume-rendered CT images were used to assess the malformations and to plan surgery for the treatment of the vascular anomalies. Different surgical approaches were used in the two kittens. The third cat was not operated. CT angiography is well suited for preoperative planning in cats with aberrant right subclavian artery alone or in combination with other vascular anomalies. © 2018 British Small Animal Veterinary Association.

  3. Subclavian Aberrant right artery aneurysm causing a common carotid trunk: findings in CT and MR

    International Nuclear Information System (INIS)

    Quiroga Gomez, S.; Alvarez Castells, A.; Dominguez Oronoz, R.; Gifre Bassols, L.

    1995-01-01

    We present a case of aberrant right subclavian artery aneurysm causing dysphagia, dysphonia, and Claude-Bernard-Horner's syndrome by compression of adjacent structures, initially diagnosed with plain chest radiography and barium-swallow examination. CT and MRI confirmed this vascular anomaly and showed a common carotid trunk, associated to aberrant subclavian artery in 29% of cases. (Author) 10 refs

  4. RIGHT-SIDED AORTIC ARCH WITH ABERRANT LEFT SUBCLAVIAN ARTERY AND DUPLICATION OF SUPERIOR VENA CAVA

    Directory of Open Access Journals (Sweden)

    Parikhita Hazarika

    2017-08-01

    Full Text Available Right-sided aortic arch is a rare anatomical variant present in about 0.1% of the adult population.1,2 Half of the cases are associated with an aberrant left subclavian artery (0.05%-0.1%. Right-sided aortic arch with aberrant left subclavian artery is less common than left-sided aortic arch with aberrant right subclavian artery (0.5-2.0%.3,4 A rightsided aortic arch is an anatomic variant resulting from persistence of the right fourth aortic arch and involution of the left. It can be associated with an aberrant left subclavian artery arises from Kommerell’s diverticulum. It is usually asymptomatic and diagnosed incidentally during adult age. A 40-year-old male presented with cough and a hump in the back. The patient was evaluated for scoliosis and plain CT thorax was done.

  5. Surgical treatment of massive bleeding of a right aberrant subclavian artery after oesophageal stent removal

    Directory of Open Access Journals (Sweden)

    Michael Raum

    2018-06-01

    Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery

  6. Absent right common carotid artery associated with aberrant right subclavian artery.

    Science.gov (United States)

    Uchino, Akira; Uwabe, Kazuhiko; Osawa, Iichiro

    2018-06-01

    Rarely, the external and internal carotid arteries arise separately from the brachiocephalic trunk and right subclavian artery (SA) or the aortic arch and reflect the absence of a common carotid artery (CCA). We report a 45-year-old man with absent right CCA associated with aberrant right SA, an extremely rare combination, diagnosed by computed tomography (CT) angiography during follow-up for postoperative aortic dissection. Retrospective careful observation of preoperative postcontrast CT revealed the absent right CCA. Previously reported arch variations associated with absent CCA include cervical aortic arch, double aortic arch, and right aortic arch.

  7. Aberrant right subclavian artery- suggested mechanism for esophageal foreign body impaction: Case report

    Directory of Open Access Journals (Sweden)

    Best Lael A

    2011-04-01

    Full Text Available Abstract Aberrant right subclavian artery (ARSA is asymptomatic in most cases. This variant anatomy can cause dysphagia in elderly patients. Impaction of foreign body in the esophagus is rarely the presenting symptom of ARSA. We present an eighty four years old patient who first presented with esophageal foreign body impaction and was diagnosed with an aberrant right subclavian artery compressing the esophagus just below the site of impaction. We assume that the exact place of impaction was not incidental and that a relative narrowing of the esophagus caused by the vascular anomaly is responsible for this specific presentation.

  8. A Rare Entity: Traumatic Thoracic Aortic Injury in a Patient with Aberrant Right Subclavian Artery.

    Science.gov (United States)

    Patel, Hiten Mohanbhai; Banerjee, Shubhabrata; Bulsara, Shahzad; Sahu, Tapish; Sheorain, Virender K; Grover, Tarun; Parakh, Rajiv

    2017-05-01

    Aberrant right subclavian artery is an uncommon entity incidence ranging from 0.5 to 2.5%. Management of thoracic aortic injury in the presence of such anomalies can be a challenge. We present here a case of traumatic aortic injury, which was incidentally found to have an asymptomatic aberrant right subclavian artery. The patient was managed by an endovascular repair of thoracic aortic injury with an endograft and a right carotid to subclavian artery bypass as a hybrid procedure. A 40-year male patient was brought to the emergency in shock with an alleged history of road traffic accident an hour back. After initial resuscitation as per advance trauma life support protocol, imaging revealed thoracic aortic injury with aberrant right subclavian artery with multiple rib and bilateral humerus fracture. After primary stabilization of arm fractures, the patient was shifted to a hybrid operation room. As the aortic injury was within 10 mm of the origin of both subclavian arteries, it was decided to cover the origin of both subclavian arteries and land the endograft distal to the left carotid artery origin. Since there was a right dominant vertebral artery on imaging, right carotid to right subclavian artery bypass was done with expanded polytetrafluoroethylene graft to prevent posterior circulatory stroke along with thoracic endovascular aortic repair to seal the thoracic aortic injury. After endovascular repair of thoracic aortic injury, left subclavian artery perfusion was maintained through left vertebral artery; and hence, revascularization of left subclavian artery was deferred. After management of all fractures, the patient was discharged 3 weeks after the date of admission without any complications. At 6 months follow-up, patient was stable and images showed patent bypass graft and sealed aortic injury. In a trauma setting with multiple injuries, hybrid procedure with a thoracic endograft is associated with low mortality and morbidity; hence, it is the treatment

  9. Aberrant right subclavian artery aneurysm confirmed by computerized tomography. Aneurisma de arteria subclavia derecha aberrante

    Energy Technology Data Exchange (ETDEWEB)

    Arteche, M.D.; Tejera, E.; Vega-Hazas, G.

    1991-01-01

    We present a case of aberrant right subclavian artery aneurysm in an asymptomatic woman. This disorder was found by chance in a thorax radiography due to an upper right mediastinal mass. CT confirmed the vascular anomaly as well as the aneurysm occurrence. (Author)

  10. Aberrant right vertebral artery originating from the aortic arch distal to the left subclavian artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Soo Heui; Baek, Hye Jin [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2014-03-15

    We present a rare case of an aberrant right vertebral artery originated from the distal aortic arch. This issue has been incidentally detected on a preoperative CT angiography after a stabbing injury of the cervical spinal cord. Normally, the right vertebral artery originates from the right subclavian artery. Therefore, in this case report we will review the incidence and the embryological mechanism of this aberrant course of the right vertebral artery and we will discuss as well the clinical importance of this variation.

  11. Vertebral and carotid artery anomalies in patients with aberrant right subclavian arteries

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Tzeng, Wen-Sheng; Jan, Sheng-Lin; Fu, Yun-Ching; Chen, Min-Chi; Lin, Pao-Chun; Liao, Wan-Chun; Chen, C.C.C.

    2007-01-01

    There is little published evidence regarding the patterns and prevalence of vertebral artery (VA) and common carotid artery (CCA) anomalies in patients with an aberrant right subclavian artery (ARSCA). To study the patterns and prevalence of VA and CCA anomalies in patients with ARSCA. In a 2-year period we reviewed the children referred with suspected vascular ring who had undergone multidetector-row CT. Patients with ARSCA were reviewed for VA and CCA patterns and their prevalence and relevance were calculated. In total, 102 patients with ARSCA were identified. VA anomalies were present in 16 patients (15.7%), and CCA anomalies (common carotid trunk) in 21 patients (20.6%). In some patients with VA anomalies, the right VA arose from the right CCA and in some the left VA arose from the aortic arch. When the left VA arose from the aortic arch it was situated between the left CCA and the left SCA or between the left SCA and the ARSCA. If neurointerventionalists understand these potential anomalies and their prevalence, time and contrast medium could be saved when catheterizing the VA and CCA in patients with ARSCA. (orig.)

  12. A Rare Case of Esophageal Dysphagia in Children: Aberrant Right Subclavian Artery

    Directory of Open Access Journals (Sweden)

    Claudia Barone

    2016-01-01

    Full Text Available Dysphagia is an impairment of swallowing that may involve any structures from the mouth to the stomach. Esophageal dysphagia presents with the sensation of food sticking, pain with swallowing, substernal pressure, or chronic heartburn. There are many causes of esophageal dysphagia, such as motility disorders and mechanical and inflammatory diseases. Infrequently dysphagia arises from extrinsic compression of the esophagus from any vascular anomaly of the aortic arch. The most common embryologic abnormality of the aortic arch is aberrant right subclavian artery, clinically known as arteria lusoria. This abnormality is usually silent. Here, we report a case of six-year-old child presenting to us with a history of progressive dysphagia without respiratory symptoms. A barium esophagogram showed an increase of the physiological esophageal narrowing at the level of aortic arch, while at esophagogastroduodenoscopy there was an extrinsic pulsatile compression of the posterior portion of the esophagus suggesting an extrinsic compression by an aberrant vessel. Angio-CT (computed tomography scan confirmed the presence of an aberrant right subclavian artery.

  13. Partial subclavian steal syndrome in a congenitally anomalous subclavian artery

    International Nuclear Information System (INIS)

    Krnic, A.; Sucic, Z.; Vucic, N.; Krolo, I.

    2006-01-01

    Background. A subclavian steal syndrome results from the abnormal flow of blood due to the occlusion in the subclavian artery proximal to the origin of the vertebral artery. A case of a male patient with a partial subclavian steal syndrome is presented. Case report. The syndrome was caused by a stenotic lesion of an aberrant right subclavian artery (the so called lusorian artery). The partial subclavian steal was recognized using the duplex ultrasound which showed the to and fro pattern in the right vertebral artery. Angiography of the aortic arch revealed the arterial anomaly. In our case, duplex ultrasound was a crucial method in diagnosing the partial subclavian steal syndrome. However, in order to show the arterial anomaly, the final evaluation had to be performed using arteriography. Conclusions. The early recognized partial subclavian steal syndrome provides good understanding of patient's symptoms, successful follow up, and a variety of treatment options. (author)

  14. Prenatal diagnosis of aberrant right subclavian artery in an unselected population

    Energy Technology Data Exchange (ETDEWEB)

    Song, Mi Jin; Han, Byoung Hee; Kim, Young Hwa; Yoon, So Young; Lee, Yoo Mi; Jeon, Hye Su; Park, Bo Kyung [Cheil General Hospital and Women' s Healthcare Center, Dankook University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    The purpose of this study was to determine the frequency of aberrant right subclavian artery (ARSA) among unselected fetuses and to evaluate its association with chromosomal abnormalities and other congenital anomalies.In all, 7,547 fetuses (gestational age, 20 to 34 weeks) were examined using routine antenatal sonography at our institution between April 2014 and September 2015. The right subclavian artery was assessed using grayscale and color Doppler ultrasonography in the transverse 3-vessel and tracheal view, and confirmed in the coronal plane. ARSA was found in 28 fetuses (0.4%). Further, 27 of these 28 fetuses were euploid (96.4%). Trisomy 18 was the only chromosomal anomaly (3.6%) found in the study sample. ARSA was an isolated finding in 23 of the 28 cases (82.1%). In the remaining three cases (10.7%), ARSA was accompanied with extracardiac anomalies. Other cardiac defects were present in three cases (10.7%). Isolated ARSA does not seem to be associated with a significantly increased risk of aneuploidy. However, the possibility of fetal karyotyping, which is a more invasive procedure, should be discussed in the light of the overall risk of the fetus.

  15. Aneurysmatic dissection of an aberrant right subclavian artery; Disseziierendes Aneurysma einer aberranten Arteria subclavia dextra: Diagnose mittels Ultrafast-CT

    Energy Technology Data Exchange (ETDEWEB)

    Reittner, P. [Universitaetsklinik fuer Radiologie, Graz (Austria). Abt. fuer Allgemeine Radiologie; Stacher, R. [Universitaetsklinik fuer Radiologie, Graz (Austria). Abt. fuer Allgemeine Radiologie

    1996-01-01

    Diagnosis with Ultrafast-CT: An aneurysm of an aberrant right subclavian artery is a very rare cause for dysphagia. We describe such a case in a 67-year-old patient, diagnosed with Ultrafast-CT and discuss it together in concert with the embryology and the radiological findings. (orig.) [Deutsch] Eine aberrierende Arteria subclavia dextra ist eine seltene Ursache fuer Dysphagie. Anhand eines 67jaehrigen Patienten werden Embryologie und radiologische Charakteristika, diagnostiziert mittels Ultrafast-CT, diskutiert. (orig.)

  16. A Right-sided Aortic Arch with Kommerell's Diverticulum of the Aberrant Left Subclavian Artery Presenting with Syncope

    Directory of Open Access Journals (Sweden)

    Ming-Hsun Yang

    2009-05-01

    Full Text Available A right-sided aortic arch with an aneurysm of the aberrant subclavian artery is a rare disease. We report a case of Kommerell's diverticulum of an aberrant left subclavian artery in a patient with a right-sided aortic arch. Fewer than 50 cases have been reported in the literature. A number of operative strategies are described. Right thoracotomy provides good exposure and avoids the morbidity associated with bilateral thoracotomy or sternotomy and thoracotomy. In our patient with symptoms of dysphagia, syncope, and left subclavian steal syndrome, a left thoracotomy was used. The repair was accomplished by division of a left ligamentum arteriosum, obliteration of the Kommerell's aneurysm, and an aorto-subclavian bypass. Postoperative complications included left vocal cord palsy and Horner's syndrome. Hoarseness and left ptosis recovered spontaneously 3 months after surgery, and the patient remained symptom-free at the 1-year follow-up. We believe a left thoracotomy for direct repair of Kommerell's diverticulum is a simple and safe method without the increased morbidity found in other procedures.

  17. [Right-side aortic arch with aberrant left subclavian artery and Kommerell's diverticulum. A cause of vascular ring].

    Science.gov (United States)

    Tamayo-Espinosa, Tania; Erdmenger-Orellana, Julio; Becerra-Becerra, Rosario; Balderrabano-Saucedo, Norma; Segura-Standford, Begoña

    The right-side aortic arch may be associated with aberrant left subclavian artery, in some cases this artery originates from an aneurismal dilation of the aorta called Kommerell's diverticulum. A report is presented on 2 cases of vascular ring formed by a right-side aortic arch, anomalous left subclavian artery, Kommerell's diverticulum and left patent ductus arteriosus. A review the literature was also performed as regards the embryological development and the imaging methods used to help in the diagnosis of this rare vascular anomaly. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  18. Aneurysm of the aberrant right subclavian artery – a case report

    International Nuclear Information System (INIS)

    Godlewski, Janusz; Widawski, Tomasz; Michalak, Maciej; Kmieć, Zbigniew

    2010-01-01

    The right subclavian artery, originating not from the brachiocephalic trunk but directly from the aortic arch, is a rare anatomical abnormality. ‘Arteria lusoria’ is the accepted name of the retroesophageal right subclavian artery. Such a vessel location, between the vertebral column and the esophagus, determines its course to the right. This defect may be asymptomatic, found during autopsy or coincidentally during diagnostic procedures. However, it may also be symptomatic. The course of this major blood vessel in the limited anatomical space may cause symptoms of mediastinal organ compression. The aim of this paper was to present two cases of abnormal anatomical course of the right subclavian artery and its aneurismal dilation. In this study, CT scans of the saccular aneurysm of the retroesophageal right subclavian artery were used: of a male patient diagnosed at Euromedic Diagnostics in Olsztyn and of a female patient, from the resources of the Radiological Dept. at MSWiA Hospital in Olsztyn An 85-year-old female was admitted to Hospital ER for congestive heart failure decompensation. Her chest X-ray revealed a round mass in the upper right mediastinum. Chest CT confirmed the presence of a saccular aneurysm of the lusory artery, 6.5 cm in diameter, partially filled with thrombotic material. The patient died in hospital from myocardial infarction that was not related to the aneurysm. A 61-year-old male patient had a chest X-ray which showed a round opacity on the apex of the right lung. The diagnostic process comprised also chest computed tomography. The examination showed an anomalous origin of the right subclavian artery, with aneurysmal dilation and compression of the oesophagus and of the trachea. An intraluminal thrombus was found. The patient remained under observation till the next CT examination, 6 months later. The presented rare cases of arteria lusoria aneurysm are not only casuistic reports. They also show the value of modern MDCT diagnostics

  19. Computed tomography angiography reveals stenosis and aneurysmal dilation of an aberrant right subclavian artery causing systemic blood pressure misreading in an old Pekinese dog.

    Science.gov (United States)

    Kim, Jaehwan; Eom, Kidong; Yoon, Hakyoung

    2017-06-16

    A 14-year-old dog weighing 4 kg presented with hypotension only in the right forelimb. Thoracic radiography revealed a round soft tissue opacity near the aortic arch and below the second thoracic vertebra on a lateral view. Three-dimensional computed tomography angiography clearly revealed stenosis and aneurysmal dilation of an aberrant right subclavian artery. Stenosis and aneurysm of an aberrant subclavian artery should be included as a differential diagnosis in dogs showing a round soft tissue opacity near the aortic arch and below the thoracic vertebra on the lateral thoracic radiograph.

  20. Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina in a child exposed to misoprostol during pregnancy.

    Science.gov (United States)

    Rosa, Rafael Fabiano Machado; Travi, Giovanni M; Valiatti, Fabiana; Zen, Paulo Ricardo Gazzola; Pinto, Louise Lapagesse; Kiss, Andrea; Graziadio, Carla; Paskulin, Giorgio Adriano

    2007-06-01

    Poland syndrome has been attributed to a process of vascular disruption, and exposure to misoprostol at 6-8 weeks of gestation has been shown to produce defects attributed to vascular disruption. Herein we report the first case of a patient with Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina, whose mother used misoprostol during pregnancy. A White boy of 1 year and 7 months of age, whose mother used misoprostol during the second month of pregnancy, presented with bilateral epicanthal folds, aplasia of the sternocostal head of the pectoralis major muscle with a hypoplastic nipple on the right side, and asymmetry between the upper limbs. The results of an angiotomographic study showed the presence of an aberrant right subclavian artery. Ultrasonographic evaluation showed turbulence and a high peak in the diastolic velocity in both carotid arteries, suggesting stenosis. Ophthalmologic assessment disclosed an intense bilateral tortuosity of the retinal blood vessels, with arterialnarrowing and rarefaction of the retinal pigment epithelium. This case suggests that the mechanism of vascular disruption of misoprostol could be related to the aberrant subclavian artery and the observed Poland syndrome. His retinal findings are different from those in cases described thus far in the literature, and this pattern of anomaly has never been associated with a gestational exposure to misoprostol. The possibility of a relationship of the aberrant right subclavian artery and the pattern of blood flow verified in the carotid arteries with the eye fundus abnormalities could be causally related or simply coincidental.

  1. Retroesophageal right subclavian artery: a case report and review of ...

    African Journals Online (AJOL)

    Retroesophageal right subclavian artery: a case report and review of the literature. Anthony Ocaya. Department ... the left subclavian artery, and the left common carotid artery. Adachi first .... Vol 2, New York: Harper & Row. 1968. 13. Tubbs SR ...

  2. Retroesophageal right subclavian artery: A case report and review ...

    African Journals Online (AJOL)

    Background: Variations of vessels arising from the aortic arch are numerous. One of the common anatomical variations is the right subclavian artery originating as the last branch of the aortic arch. This is a report of a case of an adult male cadaver with a retroesophageal right subclavian artery. Objective: To highlight the ...

  3. Validation of subclavian duplex velocity criteria to grade severity of subclavian artery stenosis.

    Science.gov (United States)

    Mousa, Albeir Y; Morkous, Ramez; Broce, Mike; Yacoub, Michael; Sticco, Andrew; Viradia, Ravi; Bates, Mark C; AbuRahma, Ali F

    2017-06-01

    Validation of subclavian duplex ultrasound velocity criteria (SDUS VC) to grade the severity of subclavian artery stenosis has not been established or systematically studied. Currently, there is a paucity of published literature and lack of practitioner consensus for how subclavian duplex velocity findings should be interpreted in patients with subclavian artery stenosis. The objective of the present study was to validate SDUS measurements using subclavian conventional or computed tomography angiogram (subclavian angiogram [SA])-derived measurements. Secondary objectives included measuring the correlation between SDUS peak systolic velocities and SA measurements, and to determine the optimal cutoff value for predicting significant stenosis (>70%). This is a retrospective review of all patients with suspected subclavian artery stenosis and a convenience sample of carotid artery patients who underwent SDUS and SA from May 1999 to July 2013. SA reference vessel and intralesion minimal lumen diameters were measured and compared with SDUS velocities obtained within 3 months of the imaging study. Percent stenosis was calculated using the North American Symptomatic Carotid Endarterectomy Trial method for detecting stenosis in a sufficiently large cohort. Receiver operating characteristic curves was generated for SDUS VC to predict >70% stenosis. Velocity cutoff points were determined with equal weighting of sensitivity and specificity. We examined 268 arteries for 177 patients. The majority of the arteries were for female patients (52.5%) with a mean age of 66.7 ± 11.1 years. Twenty-three arteries had retrograde vertebral artery flow and excluded from further analysis. For the remaining 245 arteries, the average peak systolic velocity was 212.6 ± 110.7 cm/s, with a range of 45-626 cm/s. Average stenosis was 25.8% ± 28.2%, with a range of 0% to 100%. Following receiver operating characteristic analysis, we found a cutoff value of >240 cm/s to be most predictive

  4. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  5. Bilateral subclavian origin of the bronchial arteries combined with absence of other origins.

    Science.gov (United States)

    Jie, Bing; Sun, Xi-Wen; Yu, Dong; Jiang, Sen

    2014-08-01

    There are numerous anatomical variations of the sites of origin of the bronchial arteries (BAs). A subclavian origin of a BA involves an aberrant artery that originates from the subclavian artery (SCA) or its branches. However, the aberrant artery usually originates directly from the SCA, and an SCA-origin BA arising from the branches of the SCA is rare. We herein present an extremely rare case of a right BA arising from the ipsilateral costocervical trunk, and a left BA arising from the ipsilateral thyrocervical trunk, in the absence of other origins of the BA. This anatomical variation was detected during pretherapeutic evaluation by multidetector-row computed tomography and confirmed by selective angiography. Recognition of these anatomic variations is important to surgical, diagnostic, and interventional radiologic procedures in the thorax.

  6. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    International Nuclear Information System (INIS)

    Ming, Zhu; Qian, Wang

    2009-01-01

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  7. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Zhu; Qian, Wang [Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China)

    2009-08-15

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  8. Subclavian artery dissection during catheterization in a patient after irradiation

    International Nuclear Information System (INIS)

    Kanazawa, Susumu; Hiraki, Yoshio; Fujie, Shunji; Sato, Nobuo.

    1997-01-01

    A 47-year-old woman with right breast cancer underwent partial mastectomy and had irradiations to the primary and metastatic sites, including the left supraclavicular region. During catheterization of the left internal mammary artery for arterial infusion therapy, the patient developed an iatrogenic dissection and subsequent occlusion of the left subclavian artery. Arterial infusion of tissue plasminogen activator into the artery resulted in recanalization and improvement of clinical signs and symptoms. (author)

  9. Right-sided aortic arch with anomalous origin of the left subclavian artery: Case report

    Directory of Open Access Journals (Sweden)

    Vučurević Goran

    2011-01-01

    Full Text Available Introduction. A right-sided aortic arch is a rare congenital defect of the aorta with incidence of 0.05% to 0.1% reported in published series. Usually it is associated with congenital heart anomalies and esophageal and tracheal compression symptoms. We present a case of a right-sided aortic arch of anomalous left subclavian artery origin, accidentally revealed during multislice CT (MSCT supraaortic branches angiography. Case Outline. A 53-year-old female patient was examined at the Outpatients’ Unit of the Vascular Surgery University Clinic for vertigo, occasional dizziness and difficulty with swallowing. Physical examination revealed a murmur of the left supraclavicular space, with 15 mmHg lower rate of arterial tension on the left arm. Ultrasound of carotid arteries revealed 60% stenosis of the left subclavian artery and bilateral internal carotid artery elongation. MSCT angiography revealed a right-sided aortic arch with aberrant separation of the left subclavian artery that was narrowed 50%, while internal carotid arteries were marginally elongated. There was no need for surgical treatment or percutaneous interventions, so that conservative treatment was indicated. Conclusion. A right-sided aortic arch is a very rare anomaly of the location and branching of the aorta. Multislice CT angiography is of great importance in the diagnostics of this rare disease.

  10. Left subclavian artery revascularization as part of thoracic stent grafting

    NARCIS (Netherlands)

    Saouti, N.; Hindori, V.; Morshuis, W.J.; Heijmen, R.H.

    2015-01-01

    OBJECTIVES: Intentional covering of the left subclavian artery (LSA) as part of thoracic endovascular aortic repair (TEVAR) can cause (posterior) strokes or left arm malperfusion. LSA revascularization can be done as prophylaxis against, or as treatment of, these complications. We report our

  11. INTERNAL BALLOON TAMPONADE - A NONSURGICAL METHOD FOR REMOVAL OF ACCIDENTALLY PLACED SHEATHS FROM THE SUBCLAVIAN ARTERY

    NARCIS (Netherlands)

    VANDIJK, RB; DENHEIJER, P; DEMUINCK, E; LIE, KI

    One of the possible complications of subclavian vein puncture is accidental puncture of the subclavian artery. If this is not noted immediately after the puncture, insertion of a large bore sheath in the subclavian artery is likely to follow. We describe our experience with a new method that enables

  12. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  13. Doppler Ultrasonography in Suspected Subclavian Artery Obstruction and in Patient Monitoring after Subclavian Stenting

    International Nuclear Information System (INIS)

    Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa

    2007-01-01

    Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations

  14. Intrathoracic lipoma masquerading as subclavian artery trauma.

    LENUS (Irish Health Repository)

    Munro, P T

    2012-02-03

    A 58 year old man was admitted to the accident and emergency department following an industrial accident in which he sustained a three part fracture dislocation of his right humerus. Chest radiography revealed a large mass in the right upper hemithorax and, when the patient became hypotensive, an emergency thoracotomy was performed. The mass was found to be a massive intrathoracic lipoma. This case shows how preexisting intrathoracic lesions may be mistaken for subclavian or great vessel trauma following violent shoulder girdle injury. The differential diagnosis of traumatic and non-traumatic intrathoracic mass lesions in chest radiography should be considered carefully.

  15. Down syndrome and aberrant right subclavian artery

    NARCIS (Netherlands)

    Roofthooft, Marcus T. R.; van Meer, Hester; Rietman, Wim G.; Ebels, Tjark; Berger, Rolf M. F.

    Down syndrome (DS) may be associated with various organ system disorders. Feeding problems are frequent in children with DS and may be caused by associated defects, including congenital heart defects, gastrointestinal defects, or endocrine disorders. In the absence of these associated conditions,

  16. Traumatic partial avulsion of a single right subclavian artery from the aortic arch and definitive repair.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Sears-Rogan, Pamela; Young, Richard S; Kanda, Louis T; Ellis, Jennifer L

    2006-01-01

    Blunt injury to the right subclavian artery is a rare complication of severe deceleration trauma often associated with significant morbidity and mortality. We describe an atypical presentation in a patient who sustained a traumatic avulsion of his right subclavian artery arising off the aortic arch. An interposition graft was used to restore the continuity of the artery to the ascending thoracic aorta.

  17. [Coronary subclavian steal syndrome: two cases after coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Penninga, L.; Damgaard, S.

    2008-01-01

    Reverse flow in the internal mammary artery (IMA) graft due to stenosis or occlusion of the proximal ipsilateral subclavian artery causes coronary subclavian steal syndrome (CSSS). We describe two patients who were diagnosed with CSSS following CABG. Patient A presented with angina pectoris...

  18. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  19. Arterial reconstruction of the brachiocephalic trunk and the subclavian arteries. 10 years' experience with a follow-up study

    DEFF Research Database (Denmark)

    Schroeder, T; Hansen, Hans Jørgen Buchardt

    1980-01-01

    During a 10-year period, 60 patients were operated on for occlusive lesions in the brachiocephalic trunk and/or the subclavian arteries proximal to the vertebral artery. Angiography showed 68 occlusive lesions, of which 64 were treated surgically. Of these, 47 exhibited subclavian steal. Sixty...

  20. Subclavian artery dissection during diagnostic cardiac catheterization: the role of conservative management.

    Science.gov (United States)

    Frohwein, S; Ververis, J J; Marshall, J J

    1995-04-01

    Dissection of the subclavian artery during routine cardiac catheterization while obtaining cannulation to the left internal mammary artery is an unusual complication and to our knowledge has never been reported. Conservative management of this vascular injury can avoid the sequelae of high-risk surgical repairs made difficult by a complex operative exposure. We describe a case in which dissection of the left subclavian artery was treated conservatively with an excellent outcome.

  1. "Classical Blalock-Taussig shunt" gone wrong: Confusing the right common carotid with right subclavian artery

    Directory of Open Access Journals (Sweden)

    A Mohammed Idhrees

    2015-01-01

    Full Text Available A 14-year-old girl underwent classical Blalock-Taussig shunt at 5 months of age. Computed tomography evaluation showed "Adachi type H" pattern of aortic arch vessels with the right common carotid artery being anastomosed to the right pulmonary artery mistaking it for the right subclavian artery.

  2. "Classical Blalock-Taussig shunt" gone wrong: Confusing the right common carotid with right subclavian artery.

    Science.gov (United States)

    Idhrees, A Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, Karunakaran

    2015-01-01

    A 14-year-old girl underwent classical Blalock-Taussig shunt at 5 months of age. Computed tomography evaluation showed "Adachi type H" pattern of aortic arch vessels with the right common carotid artery being anastomosed to the right pulmonary artery mistaking it for the right subclavian artery.

  3. [Subclavian artery rupture after road crash: many similitaries].

    Science.gov (United States)

    Rulliat, E; Ndiaye, A; David, J-S; Voiglio, E J; Lieutaud, T

    2011-12-01

    Traumatic Subclavian Arterial Ruptures (TSCAR) are rare and with a poor prognosis. The aim of this study was to describe the epidemiological data and the medical charts of the initial care of each patient suffering a TSCAR following a traffic accident. Using the register of the road crash in the Rhone department (France) that records every casualty using the AIS codes, we retrospectively reviewed the prehospital and intrahospital medical, biological and radiological charts of every patient. Follow-up was obtained at day 60 post-trauma. Among the 1181 severe traumatic injuries, five casualties have been recorded in the register with a TSCAR (0.4%). Four of the five patients died in an early dramatic fatal hemorrhagic shock. Similarities between casualties were observed for patients still alive at hospital arrival that associate 1) a two-wheel motorized rider (2-WMR) crashing without antagonist 2) a severe polytraumatism including thoracic and 3) orthopaedic lesions; 4) clinical and biological signs of a severe haemorrhagic shock; 5) radiological signs of scapulothoracic dissociation. TSCAR are rare with a high mortality. We recommend improving the early care by the recognition of the triad associating early severe shock, polytraumatism (thorax and superior limb) and radiological signs evocating scapulothoracic dissociation in a 2-WMR. These signs must lead to the operating theatre as fast as possible in association with early massive transfusions. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  4. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    Energy Technology Data Exchange (ETDEWEB)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A

    1999-09-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results.

  5. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    International Nuclear Information System (INIS)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A.

    1999-01-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results

  6. A Novel Combined Hybrid Approach to Enable Revascularisation of a Trauma-Induced Subclavian Artery Injury

    Directory of Open Access Journals (Sweden)

    C.N. Sabbagh

    Full Text Available : Introduction: This case highlights the complexity of upper limb revascularization after a subclavian artery traumatic injury and strengthens the role of a hybrid/multi-disciplinary approach to such injuries. Report: A 45-year-old male patient presented with an acute right upper limb following a traumatic injury to the right subclavian artery due to a motor vehicle accident (MVA. Associated injuries included an unstable cervical spine injury, a large open right clavicular injury, and a brain injury, which limited the potential revascularisation options available. The arm was revascularised using a hybrid endovascular/open surgical approach, namely embolization of the proximal subclavian artery (just distal to vertebral artery and a right common femoral artery to distal axillary artery bypass using prosthetic material. Discussion: Blunt injuries to the subclavian artery are often high impact, complex and associated with multiple injuries to surrounding structures, which limit the role of standard procedures used in the elective setting. This case highlights the role of multidisciplinary team involvement, using a hybrid approach and a novel distal inflow site to restore upper limb perfusion. Keywords: Upper limb, Ischemia, Trauma, Revascularization

  7. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    Science.gov (United States)

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  8. Refractory Hypotension as an Initial Presentation of Bilateral Subclavian Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Maxwell Eyram Afari

    2016-01-01

    Full Text Available Bilateral subclavian stenosis is a rare clinical condition. An interbrachial pressure difference of 15 mm Hg can raise suspicion for unilateral subclavian artery stenosis, but the diagnosis of bilateral subclavian artery stenosis can be challenging. We present a case of a 75-year-old woman who presented with refractory hypotension after surgery. Initial vitals revealed blood pressure in the 60s/50s mm Hg in both arms. Cardiopulmonary examination was remarkable for diminished pulses in all 4 extremities and audible carotid bruits. She continued to be hypotensive despite aggressive fluid resuscitation. Troponin T peaked at 0.24 ng/mL (reference < 0.04, and an echocardiogram revealed a reduction in ejection fraction (37% from 50%. Left and right heart catheterization demonstrated normal filling pressures and cardiac output. During the procedure, however, it was noted that the patient’s central blood pressure was 70–80 mm Hg higher than cuff pressures obtained in either arm. Selective angiography revealed 90% left subclavian ostial stenosis as well as 70% stenosis of the right subclavian artery.

  9. Percutaneous transluminal angioplasty of stenoses of the proximal subclavian artery

    International Nuclear Information System (INIS)

    Grote, R.; Freyschmidt, J.; Walterbusch, G.; Medizinische Hochschule Hannover

    1983-01-01

    Between August 1980 and June 1982, 12 left-sided proximal subclavian stenoses were dilated with balloon catheters. The dilatation was successful in all patients. Differences in blood pressure in the arm could be demonstrated subsequently. Recurrences occurred in two patients after seven and eleven months. Follow-up of nine patients up to 24 months showed them to be symptom-free. (orig.)

  10. Anatomical Arrangement of the Subclavian Artery Branches in the Rabbit and European Hare

    Directory of Open Access Journals (Sweden)

    Maženský D.

    2017-12-01

    Full Text Available The aim of this study was to compare the anatomical arrangements of the branches arising from the subclavian arteries in the domesticated rabbit and hare. The study was carried out on ten adult rabbits and ten adult European hares using the corrosion cast technique. After the euthanasia, the vascular network was perfused with saline. The arterial system of the entire body was injected by Batson’s corrosion casting kit No. 17. After polymerization of the medium, the maceration was carried out in KOH solution. The arrangement of the origins of the branches of the bilateral subclavian arteries were more variable in the hare. The number of branches arising from the subclavian artery were more regular in the rabbit on the right side and in the hare on the left side. In the rabbit, we found in two cases, the origins of the branches of the left subclavian artery from the aortic arch. The anatomical found between the rabbit and the hare may possibly be associated with their different ways of life.

  11. Open Repair of a 12-cm Posttraumatic Aneurysm of Right Subclavian Artery

    Directory of Open Access Journals (Sweden)

    Konstantinos Tigkiropoulos

    2017-11-01

    Full Text Available PurposeTo present a rare case of a patient with a 12-cm posttraumatic right subclavian artery aneurysm successfully treated with aneurysmectomy and innominate-axillary bypass.Case reportA 54-year-old man presented to the emergency department due to progressive dyspnea and hoarseness of voice. His medical record was unremarkable except that he had right-sided pneumothorax and multiple rib fractures from a car accident 16 years ago. A chest X-ray showed a mass in the upper lobe of the right lung, and the patient was hospitalized for further investigation. A computed tomography (CT with intravenous contrast of the thorax was performed, which depicted a giant aneurysm of the right subclavian artery. Vascular and cardiothoracic surgeons were consulted immediately, and the operation was scheduled. Aneurysmectomy and innominate-axillary bypass were performed. The patient had an uncomplicated progress and was discharged on 5 days followed by a single antiplatelet therapy and symptom-free.ConclusionPosttraumatic subclavian artery aneurysm is a rare entity. Imaging of the thorax is essential for the diagnosis and surgical preparation of the patient. Open repair remains the gold standard therapy for subclavian artery aneurysm despite the improvements in endovascular surgery in such huge aneurysms.

  12. Giant aneurysm of the right intra thoracic sub-clavian artery ...

    African Journals Online (AJOL)

    Aneurysms of the intra-thoracic subclavian artery (SCA) are rare. They are often revealed by complications. Surgical treatment is always indicated. Endovascular treatment is a less invasive alternative. We report a case of a 60 years-old woman admitted for right chest pain and dysphonia. Laryngoscopy noted a right vocal ...

  13. Changing Profiles of Diagnostic and Treatment Options in Subclavian Artery Aneurysms

    NARCIS (Netherlands)

    Vierhout, B. P.; Zeebregts, C. J.; van den Dungen, J. J. A. M.; Reijnen, M. M. P. J.

    Background: Subclavian artery aneurysms (SAAs) are rare and may cause life- and limb-threatening complications. Therapeutic options greatly differ as do access alternatives. The aim of the study was to assess its clinical presentation, diagnostics and therapeutic options as reported in the

  14. Subclavian artery aneurysm in a patient with vascular Ehlers-Danlos syndrome.

    Science.gov (United States)

    Yasuda, Shota; Imoto, Kiyotaka; Uchida, Keiji; Uranaka, Yasuko; Kurosawa, Kenji; Masuda, Munetaka

    2016-02-01

    We describe our experience of surgical treatment in a 28-year-old woman with vascular Ehlers-Danlos syndrome. A right subclavian artery aneurysm was detected. The right vertebral artery arose from the aneurysm. Digital subtraction angiography showed interruption of the left vertebral artery. The aneurysm was excised and the right vertebral artery was anastomosed end-to-side to the right common carotid artery under deep hypothermia and circulatory arrest. The patient remained very well 4 years after surgery, with no late vascular complication. © The Author(s) 2014.

  15. Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

    International Nuclear Information System (INIS)

    Smeenk, Robert M.; Kock, Mark C. J. M.; Elgersma, Otto E. H.; Schnater, Marco J.

    2011-01-01

    This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

  16. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  17. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  18. Repair of Multiple Subclavian and Axillary Artery Aneurysms in a 58-Year-Old Man with Marfan Syndrome

    OpenAIRE

    Dolapoglu, Ahmet; de la Cruz, Kim I.; Preventza, Ourania; Coselli, Joseph S.

    2016-01-01

    Dilation of the ascending aorta and aortic dissections are often seen in Marfan syndrome; however, true aneurysms of the subclavian and axillary arteries rarely seem to develop in patients who have this disease. We present the case of a 58-year-old man with Marfan syndrome who had undergone a Bentall procedure and thoracoabdominal aortic repair for an aortic dissection and who later developed multiple aneurysmal dilations of his right subclavian and axillary arteries. The aneurysms were succe...

  19. Isolation of the right subclavian artery in a patient with d-transposition of the great arteries

    Directory of Open Access Journals (Sweden)

    Alisa Arunamata

    2015-01-01

    Full Text Available Isolation of the right subclavian artery (RSCA is rare, and this finding in association with d-transposition of the great arteries (d-TGA is extremely unusual. We present a case of an isolated RSCA in a newborn with d-TGA in whom the clinical presentation was diagnostic. We discuss the imaging modalities used to confirm the diagnosis, the embryological basis of the finding, and the surgical repair.

  20. Isolation of the right subclavian artery in a patient with d-transposition of the great arteries.

    Science.gov (United States)

    Arunamata, Alisa; Perry, Stanton B; Kipps, Alaina K; Vasanawala, Shreyas S; Axelrod, David M

    2015-01-01

    Isolation of the right subclavian artery (RSCA) is rare, and this finding in association with d-transposition of the great arteries (d-TGA) is extremely unusual. We present a case of an isolated RSCA in a newborn with d-TGA in whom the clinical presentation was diagnostic. We discuss the imaging modalities used to confirm the diagnosis, the embryological basis of the finding, and the surgical repair.

  1. Subclavian Artery Pseudoaneurysm Formation 3 Months after a Game of Rugby Union

    Directory of Open Access Journals (Sweden)

    T. Evans

    2015-01-01

    Full Text Available Pseudoaneurysms of the subclavian artery remain a rare complication after fracture of the clavicle. We report a case of delayed diagnosis of a subclavian artery pseudoaneurysm after a closed fracture of the clavicle in a 15-year-old patient, 3 months after the original injury while playing rugby union. Despite several attendances to the Emergency Department with vague symptoms, the final diagnosis was confirmed by duplex ultrasound and Computed Tomography of the thorax. Surgical repair was indicated due to acute limb ischaemia from distal embolisation from a large pseudoaneurysm, with the patient making a full recovery. This case highlights the need for clinical vigilance when assessing patients, particularly on repeated occasions when their recovery appears to be impaired. A thorough history and clinical examination can raise suspicion of even rare occurrences and aid prompt management.

  2. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  3. Coronary artery with aberrant origin malignant right

    International Nuclear Information System (INIS)

    Ozcan, E.; Bozlar, U.; Demirkol, S.; Saglam, M.

    2012-01-01

    Full text: Introduction: Congenital anomalies of the coronary arteries is a major cause of sudden death, especially in young patients. Objectives and tasks: In this study we aim to present a young patient with chest pain who had malignant right coronary artery (RCA) with aberrant origin. Materials and methods: 24-year-old man who applied cardiology clinic for chest pain and palpitations especially after exercise, was referred to our clinic for coronary computed tomography (CT) angiography to evaluate coronary artery anomalies. Results: In CT angiography; we detected aberrant RCA with origin of tubularly part of ascendant aorta with a malignant course between aorta and pulmonary artery. Left main coronary artery, left anterior descending and circumflex artery had normal origin and course. Conclusion: Coronary artery with malignant course may cause sudden death especially after exercise. Coronary CT angiography has an important role in diagnosis of congenital coronary artery anomalies, with high resolution multiplanner reformatted images

  4. Contemporary management of subclavian and axillary artery injuries-A Western Trauma Association multicenter review.

    Science.gov (United States)

    Waller, Christine J; Cogbill, Thomas H; Kallies, Kara J; Ramirez, Luis D; Cardenas, Justin M; Todd, S Rob; Chapman, Kayla J; Beckman, Marshall A; Sperry, Jason L; Anto, Vincent P; Eriksson, Evert A; Leon, Stuart M; Anand, Rahul J; Pearlstein, Maura; Capano-Wehrle, Lisa; Cothren Burlew, Clay; Fox, Charles J; Cullinane, Daniel C; Roberts, Jennifer C; Harrison, Paul B; Berg, Gina M; Haan, James M; Lightwine, Kelly

    2017-12-01

    Subclavian and axillary artery injuries are uncommon. In addition to many open vascular repairs, endovascular techniques are used for definitive repair or vascular control of these anatomically challenging injuries. The aim of this study was to determine the relative roles of endovascular and open techniques in the management of subclavian and axillary artery injuries comparing hospital outcomes, and long-term limb viability. A multicenter, retrospective review of patients with subclavian or axillary artery injuries from January 1, 2004, to December 31, 2014, was completed at 11 participating Western Trauma Association institutions. Statistical analysis included χ, t-tests, and Cochran-Armitage trend tests. A p value less than 0.05 was significant. Two hundred twenty-three patients were included; mean age was 36 years, 84% were men. An increase in computed tomography angiography and decrease in conventional angiography was observed over time (p = 0.018). There were 120 subclavian and 119 axillary artery injuries. Procedure type was associated with injury grade (p < 0.001). Open operations were performed in 135 (61%) patients, including 93% of greater than 50% circumference lacerations and 83% of vessel transections. Endovascular repairs were performed in 38 (17%) patients; most frequently for pseudoaneurysms. Fourteen (6%) patients underwent a hybrid procedure. Use of endovascular versus open procedures did not increase over the duration of the study (p = 0.248). In-hospital mortality rate was 10%. Graft or stent thrombosis occurred in 7% and graft or stent infection occurred in 3% of patients. Mean follow-up was 1.6 ± 2.4 years (n = 150). Limb salvage was achieved in 216 (97%) patients. The management of subclavian and axillary artery injuries still requires a wide variety of open exposures and procedures, especially for the control of active hemorrhage from more than 50% vessel lacerations and transections. Endovascular repairs were used most often for

  5. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  6. Endovascular Treatment of an Iatrogenic Right Internal Jugular Vein- Right Subclavian Artery Fistula and Pseudoaneurysm During the Attempt of a Hemodialysis Catheter Insertion: A Case Report

    International Nuclear Information System (INIS)

    Cho, Eui Min; Kim, Hyun Lee; Kim, Dong Hyun

    2009-01-01

    Complications during the placement of a central venous catheter, via the right internal jugular vein puncture include local hematoma, hemothorax, pneumothorax, central vein thrombosis, and hemopericardium. Iatrogenic right internal jugular vein-right subclavian artery fistula with the formation of right subclavian artery pseudoaneurysms is an extremely rare complication in patients undergoing a central vein puncture. We report the case of a patient who developed a local hematoma at the vein puncture site and dyspnea due to a right internal jugular vein-subclavian artery fistula and a right subclavian artery pseudoaneurysm at the mediastinum after puncture of right internal jugular vein. The patient was successfully treated by embolization using microcoils

  7. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  8. IN THE GROSS ANATOMY LABORATORY: A REVIEW OF THE EMBRYOLOGY AND MOLECULAR GENETICS OF THE ABERRANT RIGHT SUBCLAVIAN ARTERY. En el laboratorio de Anatomía macroscópica: Revisión de la embriología y genética molecular de la arteria subclavia derecha aberra

    Directory of Open Access Journals (Sweden)

    Todd M Chappell

    2016-03-01

    Full Text Available La disección del cadáver embalsamado de una mujer de 66-años por  los estudiantes de medicina de primer año de anatomía general, reveló la presencia de una arteria subclavia derecha aberrante (ASDA de trayecto retroesofágico. La prevalencia de una ASDA en la población normal es del 0.2-2.0%. Se ha reportado que la ASDA tiene una asociación con varias deformidades congénitas, tales como el síndrome de Down, Kommerell divertículo, y varias otras anomalías. No es común asociar síntomas clínicos con la ASDA, sin embargo, el síntoma más común es la disfagia lusoria. Hemos descubierto que la ASD se originó desde la porción más distal del arco aórtico en una posición retroesofágica. Medidas pertinentes de las arterias se grabaron y un análisis para obtener información clínica, genética, y embriológica acerca de la ASDA se realizó. Como en la mayoría de los casos, el curso de la ASDA fue entre el esófago y la columna vertebral. Se ha demostrado que una región en el cromosoma humano 22 (22q11 está involucrada en el desarrollo normal de los vasos del arco aórtico. Este artículo ilustra cómo el descubrimiento de una variante a través de la disección da pie a estudiantes de medicina a aprender y repasar la literatura, sobre la embriología y la genética molecular, sobre anomalías del arco aórtico y sus correlaciones clínicas. Dissection of a 66-year-old female embalmed cadaver by medical students in a first-year gross anatomy course revealed the presence of an aberrant (retroesophageal right subclavian artery (ARSA. The prevalence of an ARSA is between 0.2-2.0% in the normal population. ARSA has been reported to have an association with various congenital deformities, such as Down syndrome, Kommerell diverticulum, and various other anomalies. Clinical symptoms are usually not associated with ARSAs but when present, the most common symptom is dysphagia lusoria. We discovered that the RSA originated from the most

  9. Severe upper extremity polyneuropathy due to inferior brachial plexus compression as a result of left subclavian artery pseudoaneurism

    Directory of Open Access Journals (Sweden)

    George Kosmadakis

    2012-01-01

    Full Text Available In the present report, we describe the case of a 76-year-old hemodialysis patient who was admitted with clinical features of neurological thoracic exit syndrome due to subclavian artery pseudoaneurism following the insertion of a dual lumen vascular internal jugular catheter (vascath with excellent outcome after endo-arterial stent placement.

  10. Results of subclavian to carotid artery bypass for occlusive disease of the common carotid artery: A retrospective cohort study.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio, Francesco G; Masci, Federica; Pasqua, Rocco; Frezzotti, Francesca; Peschillo, Simone

    2018-05-01

    Optimal treatment of significant atherosclerosis of the common carotid artery (CCA) is not well-defined. The purpose of this study was to evaluate the long-term results of prosthetic subclavian to carotid bypass for occlusive disease of the CCA. From January 1994 to December 2015, 45 patients, mean age 67 years, underwent an ipsilateral subclavian to carotid bypass for occlusive disease of the CCA. Thirty-eight patients (84%) presented with neurologic symptoms, including transitory ischemic attacks in 29 cases and minor strokes in 9 cases. The graft material consisted of a 7 mm polytetrafluoroethylene conduit, and the distal anastomosis was done on the carotid bulb in 21 patients, on the internal carotid artery in 19 cases, and on the distal CCA in 5 cases. Median length of follow-up was 58 months. Study endpoints were the combined postoperative stroke/mortality rate, graft infection, overall late survival, freedom from ipsilateral stroke, and graft patency. Postoperative stroke/mortality rate was 2%. No graft infection was observed throughout follow-up. At 60 months, overall survival, freedom from stroke, and graft patency were 71% (standard error [SE] = 0.07), 98% (SE = 0.02), and 95.5% (SE = 0.06), respectively. Subclavian to carotid bypass allows very good patency rates and excellent protection from postoperative and late stroke, remaining a benchmark for any other treatment method. Copyright © 2018. Published by Elsevier Ltd.

  11. Treatment of an Unusual Occurrence of a Complex Left Subclavian Artery/Left Internal Mammary Artery Bifurcation Stenosis in the Setting of Coronary Subclavian Steal Syndrome and Ischemic Left Ventricular Systolic Dysfunction

    Directory of Open Access Journals (Sweden)

    Michael J. Martinelli

    2018-01-01

    Full Text Available This case will illustrate the clinical and unique technical challenges, not previously reported, in a patient with a history of progressive left ventricular (LV systolic dysfunction, congestive heart failure (CHF, myocardial infarction (MI, and a complex bifurcation lesion of the left subclavian artery (SA involving the left internal mammary artery (LIMA in the setting of coronary subclavian steal syndrome (CSSS. The approach to this lesion is complicated by significant LIMA involvement requiring intervention directed toward both the SA and the LIMA in the presence of severe LV systolic dysfunction. This clinical scenario necessitates a careful technique, utilizing bifurcation methods similar to those used in coronary intervention.

  12. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  13. Association of left subclavian artery coverage without revascularization and spinal cord ischemia in patients undergoing thoracic endovascular aortic repair: A Vascular Quality Initiative® analysis.

    Science.gov (United States)

    Teixeira, Pedro Gr; Woo, Karen; Beck, Adam W; Scali, Salvatore T; Weaver, Fred A

    2017-12-01

    Objectives Investigate the impact of left subclavian artery coverage without revascularization on spinal cord ischemia development in patients undergoing thoracic endovascular aortic repair. Methods The Vascular Quality Initiative thoracic endovascular aortic repair module (April 2011-July 2014) was analyzed. Patients undergoing left subclavian artery coverage were divided into two groups according to revascularization status. The association between left subclavian artery revascularization with the primary outcome of spinal cord ischemia and the secondary outcome of stroke was assessed with multivariable analysis adjusting for between-group baseline differences. Results The left subclavian artery was covered in 508 (24.6%) of the 2063 thoracic endovascular aortic repairs performed. Among patients with left subclavian artery coverage, 58.9% underwent revascularization. Spinal cord ischemia incidence was 12.1% in the group without revascularization compared to 8.5% in the group undergoing left subclavian artery revascularization (odds ratio (95%CI): 1.48(0.82-2.68), P = 0.189). Multivariable analysis adjustment identified an independent association between left subclavian artery coverage without revascularization and the incidence of spinal cord ischemia (adjusted odds ratio (95%CI): 2.29(1.03-5.14), P = 0.043). Although the incidence of stroke was also higher for the group with a covered and nonrevascularized left subclavian artery (12.1% versus 8.5%), this difference was not statistically significant after multivariable analysis (adjusted odds ratio (95%CI): 1.55(0.74-3.26), P = 0.244). Conclusion For patients undergoing left subclavian artery coverage during thoracic endovascular aortic repair, the addition of a revascularization procedure was associated with a significantly lower incidence of spinal cord ischemia.

  14. Repair of Multiple Subclavian and Axillary Artery Aneurysms in a 58-Year-Old Man with Marfan Syndrome.

    Science.gov (United States)

    Dolapoglu, Ahmet; de la Cruz, Kim I; Preventza, Ourania; Coselli, Joseph S

    2016-10-01

    Dilation of the ascending aorta and aortic dissections are often seen in Marfan syndrome; however, true aneurysms of the subclavian and axillary arteries rarely seem to develop in patients who have this disease. We present the case of a 58-year-old man with Marfan syndrome who had undergone a Bentall procedure and thoracoabdominal aortic repair for an aortic dissection and who later developed multiple aneurysmal dilations of his right subclavian and axillary arteries. The aneurysms were successfully repaired by means of a surgical bypass technique in which a Dacron graft was placed between the carotid and brachial arteries. We also discuss our strategy for determining the optimal surgical approach in these patients.

  15. J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kusano, Shoichi; Makita, Kohzoh

    2004-01-01

    The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

  16. Aberrant ovarian artery arising from the common Iliac artery: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Kyung [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Yang, Seung Boo; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of); Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  17. Aberrant ovarian artery arising from the common Iliac artery: Case report

    International Nuclear Information System (INIS)

    Kim, Won Kyung; Yang, Seung Boo; Lee, Jae Myeong; Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo

    2013-01-01

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  18. Carotid-subclavian bypass for subclavian steal syndrome following coarctation repair in infancy

    Directory of Open Access Journals (Sweden)

    Scott Chowning

    2012-01-01

    Full Text Available A 19 year old man presented with dizziness that was exacerbated while using left arm. On investigation, subclavian steal syndrome (SSS was diagnosed. He underwent left carotid to subclavian bypass with relief of symptoms. Subclavian steal syndrome, although rare, should be considered in the differential diagnosis in patients with the history of subclavian artery manipulation in the past in proper settings.

  19. Circumflex coronary artery with aberrant origin and atherosclerosis

    International Nuclear Information System (INIS)

    Ozcan, E.; Bozlar, U.; Celik, T.; Tasar, M.

    2012-01-01

    Full text: Introduction: Circumflex (Cx) coronary artery congenital anomaly is reported to be less than 1% incidence. Coronary arteries with aberrant origin are more likely to have atherosclerosis according to some published literatures. Objectives and tasks: In this study we aim to present computed tomography (CT) angiography findings of a patient, who has Cx artery with aberrant origin and atherosclerotic. Materials and methods: 57-year-old woman without any symptoms who has risk factors to atherosclerosis was referred to our clinic for coronary CT angiography. Results: In CT angiography; we detected Cx coronary artery with aberrant origin (right sinus of valsalva) and retroaortic course. Also we saw intimal irregularities and calcified plaque causing severe narrowing in the proximal segment of artery. Right coronary and left anterior descendant arteries had mild atherosclerosis. Conclusion: Coroner CT angiography, which allows multiplanar imaging with high resolution, is an effective diagnostic tool for coronary artery disease, like not only congenital anomalies but also acquired atherosclerotic disease

  20. Initial and Long-Term Results of Endovascular Therapy for Chronic Total Occlusion of the Subclavian Artery

    International Nuclear Information System (INIS)

    Babic, Srdjan; Sagic, Dragan; Radak, Djordje; Antonic, Zelimir; Otasevic, Petar; Kovacevic, Vladimir; Tanaskovic, Slobodan; Ruzicic, Dusan; Aleksic, Nikola; Vucurevic, Goran

    2012-01-01

    Purpose: To study the initial and long-term results of angioplasty and primary stenting for the treatment of chronic total occlusion (CTO) of the subclavian artery (SA). Materials and Methods: From January 1999 to February 2010, 56 patients (25 men with a mean age of 58 ± 8 years) underwent endovascular treatment for CTO of the SA. Duplex scans and arteriograms confirmed occlusion in all cases. Indications for recanalization were subclavian steal syndrome in 33 patients (58.1%), arm claudication in 13 patients (23.2%), and coronary ischemia in 7 patients (12.5%) who had a history of previous coronary artery bypass grafting that included left internal thoracic artery graft. Three patients (5.4%) were treated before the scheduled coronary artery bypass surgery, which included left internal thoracic artery graft. After successful recanalization, all arteries were stented, and all of the patients were followed-up at 1, 3, 6, and 12 months after surgery and annually thereafter. Results: Successful recanalization of the SA was achieved in 46 patients (82.1%), and the complication rate was 7.1%. During follow-up (mean 40 ± 26 months; range 2 to 125), the primary patency rates after 1 and 3 years were 97.9% and 82.7%, respectively. At the end of follow-up, 76% of the arteries showed no evidence of restenosis. Univariate analysis failed to identify any variable predictive of long-term patency of successfully recanalized SA. Conclusion: Percutaneous transluminal angioplasty with stenting of the complete total occlusion of the SA is a safe and effective procedure associated with low risks and good long-term results.

  1. Irradiation-induced changes in the subclavian and axillary arteries after radiotherapy for carcinoma of the breast

    International Nuclear Information System (INIS)

    Kretschmer, G.; Niederle, B.; Polterauer, P.; Waneck, R.

    1986-01-01

    Three case reports are reviewed to illustrate the possibility of treating irradiation-induced lesions of the subclavian-brachial vascular segment (aneurysm and segmental occlusions) 14, 20, and 26 years after radical mastectomy and subsequent radiotherapy. All patients had an extraanatomic vein bypass graft from the carotid to the brachial artery crossing the shoulder near the acromioclavicular joint, with the advantage that the tissue changed by radiotherapy or infected by ulceration could be circumvented. There were no postoperative complications, with adequate function of the grafts (follow-up, 17, 24, and 20 months, respectively)

  2. Intentional left subclavian artery coverage during thoracic endovascular aortic repair for traumatic aortic injury.

    Science.gov (United States)

    McBride, Cameron L; Dubose, Joseph J; Miller, Charles C; Perlick, Alexa P; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Thoracic endovascular aortic repair (TEVAR) is widely used for treatment of traumatic aortic injury (TAI). Stent graft coverage of the left subclavian artery (LSA) may be required in up to 40% of patients. We evaluated the long-term effects of intentional LSA coverage (LSAC) on symptoms and return to normal activity in TAI patients compared with a similarly treated group whose LSA was uncovered (LSAU). Patients were identified from a prospective institutional trauma registry between September 2005 and July 2012. TAI was confirmed using computed tomography angiography. The electronic medical records, angiograms, and computed tomography angiograms were reviewed in a retrospective fashion. In-person or telephone interviews were conducted using the SF-12v2 (Quality Metrics, Lincoln, RI) to assess quality of life. An additional questionnaire was used to assess specific LSA symptoms and the ability to return to normal activities. Data were analyzed by Spearman rank correlation and multiple linear and logistic regression analysis with appropriate transformations using SAS software (SAS Institute, Cary, NC). During the study period, 82 patients (57 men; mean age 40.5 ± 20 years, mean Injury Severity Score, 34 ± 10.0) underwent TEVAR for treatment of TAI. Among them, LSAC was used in 32 (39.5%) and LSAU in 50. A group of the LSAU patients (n = 22) served as matched controls in the analysis. We found no statistically significant difference in SF-12v2 physical health scores (ρ = -0.08; P = .62) between LSAC and LSAU patients. LSAC patients had slightly better mental health scores (ρ = 0.62; P = .037) than LSAU patients. LSAC patients did not have an increased likelihood of experiencing pain (ρ = -0.0056; P = .97), numbness (ρ = -0.12; P = .45), paresthesia (ρ = -0.11; P = .48), fatigue (ρ = -0.066; P = .69), or cramping (ρ = -0.12; P = .45). We found no difference between groups in the ability to return to activities. The mean follow-up time was 3.35 years. Six LSAC

  3. Aberrant overian artery originating from the Ilolumbar artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-05-15

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE.

  4. Aberrant overian artery originating from the Ilolumbar artery: A case report

    International Nuclear Information System (INIS)

    Lee, Ji Eun; Lee, Jae Myeong

    2016-01-01

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE

  5. Aberrant internal carotid artery in the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Keun Tak; Kang, Hyun Koo [Dept. of Radiology, Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2014-10-15

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  6. Aberrant internal carotid artery in the middle ear

    International Nuclear Information System (INIS)

    Roh, Keun Tak; Kang, Hyun Koo

    2014-01-01

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  7. Right aortic arch with aberrant left subclavian artery—prenatal diagnosis and evaluation of postnatal outcomes: Report of three cases

    Directory of Open Access Journals (Sweden)

    Kuei-Cheng Hsu

    2011-09-01

    Conclusion: The 3VT view in routine prenatal ultrasound examination is important and essential for the prenatal diagnosis of an RAA with an aberrant LSCA. Moreover, 3D-PDU is able to provide a more clear-cut cardiovascular structure, which helps with the diagnosis.

  8. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joon Ho; Kim, Man Deuk, E-mail: mdkim@yuhs.ac; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital (Korea, Republic of)

    2013-02-15

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  9. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    International Nuclear Information System (INIS)

    Kwon, Joon Ho; Kim, Man Deuk; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun

    2013-01-01

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  10. A Rare Case of Esophageal Dysphagia in Children: Aberrant Right Subclavian Artery

    OpenAIRE

    Barone, Claudia; Carucci, Nicolina Stefania; Romano, Claudio

    2016-01-01

    Dysphagia is an impairment of swallowing that may involve any structures from the mouth to the stomach. Esophageal dysphagia presents with the sensation of food sticking, pain with swallowing, substernal pressure, or chronic heartburn. There are many causes of esophageal dysphagia, such as motility disorders and mechanical and inflammatory diseases. Infrequently dysphagia arises from extrinsic compression of the esophagus from any vascular anomaly of the aortic arch. The most common embryolog...

  11. Aberrant internal carotid artery presenting as a retrotympanic vascular mass

    International Nuclear Information System (INIS)

    Nicolay, Simon; De Foer, Bert; Bernaerts, Anja; Van Dinther, Joost; Parizel, Paul M

    2014-01-01

    We report a case of a young woman with an aberrant right internal carotid artery (ICA) presenting as a retrotympanic reddish mass. This variant of the ICA represents the collateral pathway that is formed as a result of an embryological agenesis of the cervical segment of the ICA. The embryonic inferior tympanic artery is recruited to bypass the absent carotid segment. This hypertrophied vessel may be seen otoscopically and wrongfully considered to be a vascular middle ear tumor. Informing the otorhinolaryngologist of this important vascular variant not only obviates biopsy but also helps in careful preoperative planning of eventual middle ear procedures

  12. Hybrid treatment of dysphagia lusoria: right carotid to subclavian bypass and endovascular insertion of an Amplatzer II Vascular Plug

    Directory of Open Access Journals (Sweden)

    Ernesto Cobos-González

    Full Text Available Compression of the esophagus by a retroesophageal aberrant right subclavian artery (ARSA is a rare cause of dysphagia. We present the case of a 47-year-old female with symptoms of progressive dysphagia diagnosed with dysphagia lusoria using barium swallow and contrast computed tomography and successfully treated with a hybrid procedure: right carotid to subclavian bypass and endovascular insertion of an Amplatzer II Vascular Plug through the right superficial femoral artery. We consider this approach safer, less invasive and more complete to avoid recurrent dysphagia.

  13. The Effect of a Third Generation Hemostatic Dressing in a Subclavian Artery and Vein Transection Porcine Model

    Science.gov (United States)

    2014-04-01

    small skin incision. The exposed subclavian vessels were treated with lidocaine , transected and allowed to free bleed for thirty seconds prior to...achieve hemorrhage control (Butler & Blackbourne, 2012) is typically ineffective in this region because pressure over the clavicle will not be...cavity depth, and cavity volume. The subclavian vessels were then immersed in 30 mL of 2% lidocaine (Phoenix Pharmaceuticals, St. Joseph, MO) for 10

  14. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  15. DSA - a helpful tool in diagnosis of aberrant left pulmonary artery (vascular sling) in adults

    International Nuclear Information System (INIS)

    Mooyaart, E.L.; Boomsma, J.H.B.; Postmus, P.E.; Formanek, G.A.

    1985-01-01

    Two new adult patients with aberrant origin of the left pulmonary artery from the right pulmonary artery - pulmonary artery sling - are described, totalling the published adult cases to eight. Differentiation from a mediastinal mass closely mimicking this vascular anomaly is discussed. For the definitive diagnosis, digital subtraction angiography was applied for the first time. The clearest demonstration of the anatomy is in 20-25 0 RPO and 20-25 0 sitting position. The aberrant left pulmonary artery in adults is asymptomatic.

  16. PHACE association with intracranial, oropharyngeal hemangiomas, and an atypical patent ductus arteriosus arising from the tortuous left subclavian artery in a premature infant

    Directory of Open Access Journals (Sweden)

    Do-Hyun Kim

    2012-01-01

    Full Text Available PHACE association is a rare neurocutaneous condition in which facial hemangiomas associate with a spectrum of posterior fossa malformations, arterial cerebrovascular anomalies, cardiovascular anomalies, and eye anomalies. We reported a case of PHACE association in a premature infant showing facial, intracranial, and oropharyngeal hemangiomas with evidence of the Dandy-Walker variant and complicated cardiovascular anomalies, including a right-sided aortic arch and an atypical patent ductus arteriosus arising from a tortuous left subclavian artery. To our knowledge, intracranial hemangiomas are rare in PHACE association, and a concomitant oropharyngeal hemangioma has not been previously reported in the PHACE association literature. In infants presenting with large, plaque-like facial hemangiomas, it is important to conduct active cardiovascular and neurological evaluations. Special attention should be given to the laryngoscopic examination to search for additional hemangiomas in the airway.

  17. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  18. Subclavian steal syndrome without subclavian stenosis

    Directory of Open Access Journals (Sweden)

    Matt Cwinn, MD

    2017-09-01

    Full Text Available Subclavian steal syndrome (SSS has been well described in the setting of subclavian stenosis. We describe an unusual case of SSS caused by a high-flow arteriovenous dialysis fistula in the absence of subclavian stenosis, provide a review of the literature, and propose that arteriovenous fistula-induced SSS is an underdiagnosed cause of syncope in this population of patients.

  19. Surgical repair of an aberrant splenic artery aneurysm: report of a case.

    Science.gov (United States)

    Illuminati, Giulio; LaMuraglia, Glenn; Nigri, Giuseppe; Vietri, Francesco

    2007-03-01

    Aneurysms of the splenic artery are the most common splanchnic aneurysms. Aneurysms of a splenic artery with an anomalous origin from the superior mesenteric artery are however rare, with eight previously reported cases. Their indications for treatment are superposable to those of aneurysms affecting an orthotopic artery. Methods of treatment of this condition include endovascular, minimally invasive techniques and surgical resection. We report one more case of aneurysm of an aberrant splenic artery, treated with surgical resection, and preservation of the spleen.

  20. Resection-Reconstruction of Aberrant Right Hepatic Artery During Whipple Procedure (Pancreaticoduodenectomy).

    Science.gov (United States)

    Sayyed, Raza; Rehman, Iffat; Niazi, Imran Khalid; Yusuf, Muhammed Aasim; Syed, Aamir Ali; V, Faisal

    2016-06-01

    Aberrant hepatic arterial anatomy poses a challenge for the surgeon during Whipple procedure. Intraoperative injury to the aberrant vasculature results in hemorrhagic or ischemic complications involving the liver and biliary tree. We report a case of replaced right hepatic artery arising from the superior mesenteric artery in a patient with periampullary carcinoma of the pancreas, undergoing pancreaticoduodenectomy. The aberrant artery was found to be coursing through the pancreatic parenchyma. This is a rare vascular anomaly. Resection of the arterial segment and end-to-end anastomosis was fashioned. Intrapancreatic course of the replaced right hepatic artery is a rare anomaly and is best managed by preoperative identification on radiology and meticulous intra-operative dissection and preservation. However, for an intrapancreatic course, resection and reconstruction may occasionally be required.

  1. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  2. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  3. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  4. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  5. Aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery arising from the right pulmonary artery: A case report

    International Nuclear Information System (INIS)

    Cho, Yong Seok; Kang, Mi Jin; Bae, Kyung Eun; Lee, Jin Hae; Lee, Han Bee; Kim, Jae Hyung; Jeong, Myeong Ja; Kang, Tae Kyung

    2013-01-01

    Aberrant origins of the pulmonary artery are rare anomalies, but are being reported several times in the world literature. Among them, pulmonary artery sling is the most well known anomaly, which is the left pulmonary artery arising from the right pulmonary artery. In case of pulmonary artery sling, the left pulmonary artery causes compression of the trachea and esophagus while it courses in between. In this case, we describe a case on incidentally found aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery without any compressions of the esophagus or trachea. In the world literature, aberrant origins of the left pulmonary artery without pulmonary artery sling was reported at one time, but currently, this is the first case of aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery arising from the right pulmonary artery.

  6. Aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery arising from the right pulmonary artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Seok; Kang, Mi Jin; Bae, Kyung Eun; Lee, Jin Hae; Lee, Han Bee; Kim, Jae Hyung; Jeong, Myeong Ja; Kang, Tae Kyung [Sanggye Paik Hospital, Inje University College of Medicine, Seoul, (Korea, Republic of)

    2013-10-15

    Aberrant origins of the pulmonary artery are rare anomalies, but are being reported several times in the world literature. Among them, pulmonary artery sling is the most well known anomaly, which is the left pulmonary artery arising from the right pulmonary artery. In case of pulmonary artery sling, the left pulmonary artery causes compression of the trachea and esophagus while it courses in between. In this case, we describe a case on incidentally found aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery without any compressions of the esophagus or trachea. In the world literature, aberrant origins of the left pulmonary artery without pulmonary artery sling was reported at one time, but currently, this is the first case of aberrant origin of the upper left lobe anterior and superior lingular segmental pulmonary artery arising from the right pulmonary artery.

  7. A new variant of aberrant left brachiocephalic trunk in mam: case report and literature review.

    Science.gov (United States)

    Szpinda, Michał

    2005-02-01

    Importance is placed on aberrant arteries in the radiological and surgical literature. A normal left brachiocephalic trunk is characteristic for the right aortic arch. However, an aberrant left brachiocephalic trunk arising as the last branch of the aortic arch on the left side has not yet been described in the literature. Described here is a new variant of the retro-oesophageal aberrant left brachiocephalic trunk, occasionally observed in a patient during diagnostic investigation or surgical treatment for steno-obstructive involvement of the carotid district. The triple anomaly of the left aortic arch consisted of: 1. the presence of a hypoplastic left brachiocephalic trunk behind the oesophagus, 2. the absence of a brachiocephalic trunk on the right side and 3. separate origins of the arteries on the right side, with the right common artery preceding the right subclavian artery. In front of the trachea an 8-mm prosthetic PTFE was implanted from the proximal segment of the right subclavian artery to the junction of the left common carotid and left subclavian arteries. The author demonstrates the inadequacy of auxiliary investigations to detect aberrant arteries, which may only be identified precisely intra-operatively.

  8. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  9. Aberrant Left Inferior Bronchial Artery Originating from the Left Gastric Artery in a Patient with Acute Massive Hemoptysis

    International Nuclear Information System (INIS)

    Jiang, Sen; Sun, Xi-Wen; Yu, Dong; Jie, Bing

    2013-01-01

    Massive hemoptysis is a life-threatening condition, and the major source of bleeding in this condition is the bronchial circulation. Bronchial artery embolization is a safe and effective treatment for controlling hemoptysis. However, the sites of origin of the bronchial arteries (BAs) have numerous anatomical variations, which can result in a technical challenge to identify a bleeding artery. We present a rare case of a left inferior BA that originated from the left gastric artery in a patient with recurrent massive hemoptysis caused by bronchiectasis. The aberrant BA was embolized, and hemoptysis has been controlled for 8 months

  10. Aberrant Left Inferior Bronchial Artery Originating from the Left Gastric Artery in a Patient with Acute Massive Hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Sen, E-mail: jasfly77@vip.163.com; Sun, Xi-Wen, E-mail: xwsun@citiz.net; Yu, Dong, E-mail: yudong_mail@126.com; Jie, Bing, E-mail: jbshh@163.com [Shanghai Pulmonary Hospital, Tongji University School of Medicine, Department of Radiology (China)

    2013-10-15

    Massive hemoptysis is a life-threatening condition, and the major source of bleeding in this condition is the bronchial circulation. Bronchial artery embolization is a safe and effective treatment for controlling hemoptysis. However, the sites of origin of the bronchial arteries (BAs) have numerous anatomical variations, which can result in a technical challenge to identify a bleeding artery. We present a rare case of a left inferior BA that originated from the left gastric artery in a patient with recurrent massive hemoptysis caused by bronchiectasis. The aberrant BA was embolized, and hemoptysis has been controlled for 8 months.

  11. Supraclavicular versus Infraclavicular Subclavian Vein Catheterization in Infants

    Directory of Open Access Journals (Sweden)

    Wen-Hsien Lu

    2006-04-01

    Conclusion: In our study, we found that there was no statistically significant difference among the 4 SVC locations in effectiveness of operation or in risk of complication. There was a tendency to damage the subclavian arteries through the supraclavicular route.

  12. Two-phase summation imaging using transvenous DSA in subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1984-01-01

    A simple method is reported to obtain a two-phase summation image in subclavian steal syndrome using digital subtraction angiography (DSA) via selection of a mask during the early arterial phase and the contrast image during delayed retrograde filling of the ipsilateral vertebral artery and the postocclusive subclavian artery. The summation image results by employing replay of the stored image information. (orig.) [de

  13. A pulmonary sequestered segment with an aberrant pulmonary arterial supply: A case of unique anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Chul; Woo, Jeong Joo; An, Jin Kyung; Jung, Yoon Young; Choi, Yun Sun [Dept. of Radiology, Eulji Hospital, Eulji University, Seoul (Korea, Republic of)

    2016-04-15

    We presented a rare case of a 64-year-old man with a combined anomaly of the bronchus and pulmonary artery that was detected incidentally. Computed tomography showed a hyperlucent, aerated sequestered segment of the right lower lung with an independent ectopic bronchus, which had no connection to the other airway. The affected segment was supplied by its own aberrant pulmonary artery branch from the right pulmonary trunk. This anomaly cannot be classified with any of the previously reported anomalies.

  14. Right pulmonary aplasia, aberrant left pulmonary artery, and bronchopulmonary sequestration with an esophageal bronchus

    International Nuclear Information System (INIS)

    Lee, Peter; McCauley, Roy; Westra, Sjirk; Baba, Timothy

    2006-01-01

    Pulmonary aplasia and bronchopulmonary foregut malformations in which a patent communication between the foregut and the pulmonary system is present are rare congenital abnormalities. Pulmonary aplasia associated with a pulmonary sling is an even rarer abnormality. We report a unique case of right pulmonary aplasia, aberrant left pulmonary artery, and bronchopulmonary sequestration with an esophageal bronchus diagnosed by multidetector helical CT. (orig.)

  15. Aberrant hepatic arterial anatomy and the whipple procedure: lessons learned.

    Science.gov (United States)

    Chamberlain, Ronald S; El-Sedfy, Abraham; Rajkumar, Dhiraj

    2011-05-01

    Appreciation and study of hepatic arterial anatomical variability is essential to the performance of a pancreaticoduodenectomy to avoid surgical complications such as bleeding, hepatic ischemia/failure, and anastomotic leak/stricture. Awareness of this variability permits the surgeon to adapt the surgical technique to deal with anomalies identified preoperatively or intraoperatively thereby preventing unnecessary surgical morbidity and mortality. The objective of our study is to provide a comprehensive review of the anatomic arterial anomalies and discuss surgical strategies that will equip the surgeon to deal with all anomalies that may be encountered a priori or en passant during the course of a Whipple procedure.

  16. Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

    DEFF Research Database (Denmark)

    Kristensen, Katrine Lawaetz; Duus, Louise Aarup; Elle, Bo

    2015-01-01

    An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel...... is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant...

  17. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  18. Congenital anomalous/aberrant systemic artery to pulmonary venous fistula: Closure with vascular plugs & coil embolization

    Directory of Open Access Journals (Sweden)

    Pankaj Jariwala

    2014-01-01

    Full Text Available A 7-month-old girl with failure to thrive, who, on clinical and diagnostic evaluation [echocardiography & CT angiography] to rule out congenital heart disease, revealed a rare vascular anomaly called systemic artery to pulmonary venous fistula. In our case, there was dual abnormal supply to the entire left lung as1 anomalous supply by normal systemic artery [internal mammary artery]2 and an aberrant feeder vessel from the abdominal aorta. Left Lung had normal bronchial connections and normal pulmonary vasculature. The fistula drained through the pulmonary veins to the left atrium leading to ‘left–left shunt’. Percutaneous intervention in two stages was performed using Amplatzer vascular plugs and coil embolization to close them successfully. The patient gained significant weight in follow up with other normal developmental and mental milestones.

  19. A coincidental variation of the axillary artery: the brachioradial artery and the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Marek Konarik

    2014-09-01

    Full Text Available A case of anomalous terminal branching of the axillary artery was encountered and described in a left upper limb of a male cadaver. A series of 214 upper limbs of Caucasian race was dissected. A variant artery, stemming from the very end of the axillary artery followed a superficial course distally. It passed the cubital fossa, ran on the lateral side of the forearm as usual radial artery, crossed ventrally to the palm and terminated in the deep palmar arch. This vessel is a case of the brachioradial artery (incorrectly termed as the “radial artery with high origin”. Moreover, it was associated with another variation, concerning the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle. The anatomical knowledge of the axillary region is essential for radiodiagnostic, surgical and traumatologic procedures. The superficially located artery brings an elevated danger of heavy bleeding in all unexpected situations, its variant branching can cause problems in radial catheterization procedures and the anomalously coursing other arterial variant poses an elevated danger in surgical procedures concerning the surgical neck of humerus.

  20. Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, Katrine Lawaetz, E-mail: klk@dadlnet.dk [Odense University Hospital, Department of Thoracic and Vascular Surgery (Denmark); Duus, Louise Aarup, E-mail: louise.brodersen@gmail.com [Sygehus Lillebaelt Vejle, Department of Radiology (Denmark); Elle, Bo, E-mail: Bo.Elle@rsyd.dk [Odense University Hospital, Department of Radiology (Denmark)

    2015-10-15

    An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant aneurysmal branch from the abdominal aorta to the normal basal segments of the lung, successfully occluded with an Amplatzer Vascular Plug II (AVP II, St.Jude Medical, MN, USA) alone.

  1. Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

    International Nuclear Information System (INIS)

    Kristensen, Katrine Lawaetz; Duus, Louise Aarup; Elle, Bo

    2015-01-01

    An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant aneurysmal branch from the abdominal aorta to the normal basal segments of the lung, successfully occluded with an Amplatzer Vascular Plug II (AVP II, St.Jude Medical, MN, USA) alone

  2. Combined resection of aberrant right hepatic artery without anastomosis in panceaticoduodenectomy for pancreatic head cancer: A case report.

    Science.gov (United States)

    Nanashima, Atsushi; Imamura, Naoya; Tsuchimochi, Yuki; Hiyoshi, Masahide; Fujii, Yoshiro

    2016-01-01

    This case report is intended to inform pancreas surgeons of our experience in operative management of aberrant pancreatic artery. A 63-year-old woman was admitted to our institute's Department of Surgery with obstructive jaundice, and the pancreas head tumor was found. To improve liver dysfunction, an endoscopic retrograde nasogastric biliary drainage tube was placed in the bile duct. Endoscopic fine-needle aspiration showed a pancreas head carcinoma invading the common bile duct, the aberrant right hepatic artery arising from the superior mesenteric artery, and the portal vein. Enhanced computed tomography showed the communicating artery between the right and left hepatic artery via the hepatic hilar plate. By way of imaging preoperative examination, a pancreaticoduodenectomy combined resection of the aberrant right hepatic artery and portal vein was conducted without arterial anastomosis. Hepatic arterial flow was confirmed by intraoperative Doppler ultrasonography, and R0 resection without tumor exposure at the dissected plane was achieved. The patient's postoperative course was uneventful. In this case report, perioperative detail examination by imaging diagnosis with respect to hepatic arterial communication to achieve curative resection in a pancreas head cancer was necessary. Non-anastomosis of hepatic artery was achieved, and the necessity of R0 resection was stressed by such management. By the preoperative and intraoperative imaging managements conducted, combined resection of the aberrant right hepatic artery without anastomosis was achieved by pancreaticoduodenectomy for pancreas head cancer. However, improvements in imaging diagnosis and careful management of R0 resection are important. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Isolated Subclavian Vein Injury: A Rare and High Mortality Case

    Directory of Open Access Journals (Sweden)

    Sahin Iscan

    2013-01-01

    Full Text Available Isolated subclavian vein injuries are rarely seen without concomitant arterial injury, bone fracture, damage to brachial plexus, and thoracal traumas. Our case was brought to the emergency service 6 hours after he had been shot at the shoulder with a firearm. After detection of extravasation from the left axillary and subclavian vein on arteriographic and venographic examinations, he was operated on. An autogenous saphenous vein graft was interposed between subclavian and axillary veins. Cardiac arrest developed twice because of hypovolemia, which was resolved with medical therapy. Subclavian vein injuries have a more mortal course when compared with the injuries to the subclavian arteries. Its most important reason is excessive blood loss and air embolism because of delayed arrival to hospital. As is the case in all vascular injuries, angiography is the most important diagnostic examination. If the general health state of the patient permits, arteriography and venography should be performed in patients potentially exposed to vascular injuries. In patients with extreme blood loss and deteriorated health state, direct surgical exploration of the injury site, containment of the bleeding, and venous repair are life-saving approaches.

  4. Espessamento médio-intimal na origem da artéria subclávia direita como marcador precoce de risco cardiovascular Intima-media thickness in the origin of right subclavian artery as an early marker of cardiovascular risk

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Engelhorn

    2006-11-01

    EMI na origem da artéria subclávia direita pode ser considerado um marcador mais precoce para avaliação de risco cardiovascular.OBJECTIVE: Common carotid artery intima-media thickness (IMT is considered a factor of cardiovascular risk and an early marker of coronary artery disease. This study aimed to investigate the existence of a correlation between IMT in the carotid arteries and at the origin of the right subclavian artery, as well as to evaluate IMT in the subclavian artery as an earlier marker of cardiovascular risk. METHODS: One hundred and six consecutive patients, 52 males and 54 females, average age 51 years, underwent color Doppler ultrasonography to evaluate carotid and right subclavian arteries. The relationship between carotid IMT and right subclavian IMT was assessed using the Pearson's correlation coefficient analysis and a 95% confidence interval. Reliability of right subclavian artery IMT measurement for the diagnosis of early thickening (considering a > 0.8 mm carotid thickness as reference was described as to sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Cut-off values for the right subclavian IMT were indicated by the ROC curve, and p values 0.8 mm. The mean IMT value for the carotid artery was 0.87 mm (SD = 0.23 and for the subclavian artery, 1.17 mm (SD = 0.46, with a 0.31 correlation coefficient (95% CI: 0.12; 0.47. The ROC curve analysis indicated a cut-off value of 0.7 mm for the right subclavian artery IMT, using as reference a 0.8 mm cut-off value for the carotid artery (91% sensitivity, 27% specificity, 66% PPV, 65% NPV, and 66% accuracy. CONCLUSION: Our study showed that carotid artery IMT correlates well with right subclavian artery IMT. With a 0.7 mm cut-off value, it is possible to detect IMT in the right subclavian artery earlier than in the carotid arteries. The IMT at the origin of the right subclavian artery can be considered an earlier marker for the assessment of cardiovascular

  5. Five cases of caudal regression with an aberrant abdominal umbilical artery: Further support for a caudal regression-sirenomelia spectrum.

    Science.gov (United States)

    Duesterhoeft, Sara M; Ernst, Linda M; Siebert, Joseph R; Kapur, Raj P

    2007-12-15

    Sirenomelia and caudal regression have sparked centuries of interest and recent debate regarding their classification and pathogenetic relationship. Specific anomalies are common to both conditions, but aside from fusion of the lower extremities, an aberrant abdominal umbilical artery ("persistent vitelline artery") has been invoked as the chief anatomic finding that distinguishes sirenomelia from caudal regression. This observation is important from a pathogenetic viewpoint, in that diversion of blood away from the caudal portion of the embryo through the abdominal umbilical artery ("vascular steal") has been proposed as the primary mechanism leading to sirenomelia. In contrast, caudal regression is hypothesized to arise from primary deficiency of caudal mesoderm. We present five cases of caudal regression that exhibit an aberrant abdominal umbilical artery similar to that typically associated with sirenomelia. Review of the literature identified four similar cases. Collectively, the series lends support for a caudal regression-sirenomelia spectrum with a common pathogenetic basis and suggests that abnormal umbilical arterial anatomy may be the consequence, rather than the cause, of deficient caudal mesoderm. (c) 2007 Wiley-Liss, Inc.

  6. Balloon catheter dilatation in the treatment of the subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1988-01-01

    The present paper reports on the results of PTA in the treatment of subclavian steal syndrome and significant proximal subclavian artery stenosis in thirteen patients. In all cases, it was possible to dilate the stenoses successfully and without complications. Cerebral symptoms caused by the steal phenomenon (seven patients) were relieved in all cases and ischaemic symptoms in the arms produced by exercise were cured in ten out of eleven patients. Balloon catheter dilatation of proximal subclavian stenosis in symptomatic patients is the treatment of choice, as judged by our own experience and the data in the literature. (orig.) [de

  7. Transarterial embolization treatment for aberrant systemic arterial supply to the normal lung: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Ra; Jo, Jeong Hyun; Park, Byeong Ho [Dept. of Radiology, Dong A University Hospital, Dong A University College of Medicine, Busan (Korea, Republic of)

    2017-06-15

    A 24-year-old man presented with dyspnea on exertion and intermittent blood-tinged sputum. He was diagnosed with aberrant systemic arterial supply to the normal lung (ASANL) based on the results of imaging studies. The patient was successfully treated with transarterial embolization using coils and a vascular plug and his symptoms disappeared during the follow-up. Herein, we reported the imaging findings of ASANL, differential diagnoses, and its treatment options. In addition, we reviewed the relevant literature.

  8. An unusual case of left aberrant innominate artery with right aortic arch: evaluation with high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio [University Rene Descartes-Paris 5, Department of Pediatric Cardiology, Hopital Necker Enfants Malades, Paris (France); Gesualdo, Francesco; Brunelle, Francis; Ou, Phalla [University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker Enfants Malades, Paris Cedex 15 (France)

    2008-01-15

    A left aberrant innominate (brachiocephalic) artery is an angiographically well-known entity that may cause tracheal compression. We report a male newborn who was admitted for further investigation of a prenatally suspected major vessel anomaly. High-resolution CT was used to completely assess the abnormal anatomy and the relationship with the airway, as well as to guide the surgical approach for its correction. (orig.)

  9. An unusual case of left aberrant innominate artery with right aortic arch: evaluation with high-resolution CT

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Gesualdo, Francesco; Brunelle, Francis; Ou, Phalla

    2008-01-01

    A left aberrant innominate (brachiocephalic) artery is an angiographically well-known entity that may cause tracheal compression. We report a male newborn who was admitted for further investigation of a prenatally suspected major vessel anomaly. High-resolution CT was used to completely assess the abnormal anatomy and the relationship with the airway, as well as to guide the surgical approach for its correction. (orig.)

  10. Stenting-plasty with brachial puncture in the treatment of subclavian steal syndrome

    International Nuclear Information System (INIS)

    Chen Quan; Jing Zaiping; Zhao Zhiqing; Feng Xiang; Lu Qingsheng; Mei Zhijun

    2007-01-01

    Objective: To study the clinical effect of stenting-plasty with retrograde brachial puncture for subclavian steal syndrome patients. Methods: To analyze the clinical results of stenting-plasty with retrograde brachial puncture in 15 patients with subclavian steal syndrome. Results: MRA or DSA showed the subclavian arteries with different degrees of stenosis (80%-100%) in all patients. Stenting-plasty with retrograde brachia] puncture was used in all patients. After placement of wall or polmaz stent, the pulse recovered and the syndrome disappeared. Postoperative angiography showed patency of the artery and stent. The patients were followed up for 3-30 months without recurrence of symptoms. Conclusions: Stenting-plasty with retrograde brachial puncture is a rather proper method to treat subclavian steal syndrome with more coincidence to the vascular anatomy, decrease the maneuver trouble and increase the successful rate. (authors)

  11. Applications and complications of subclavian vein catheterization for hemodialysis

    International Nuclear Information System (INIS)

    Kamran, T.; Zaheer, K.; Khan, A.A.; Khalid, M.; Akhtar, M.S.

    2003-01-01

    Objective: To study the indications, complications and duration of 605 subclavian catheters inserted over a period of 4 years as venous access for the management of renal failure in local setup. Results: Among the patients who underwent subclavian vien catheterization, 75.2% patients were suffering from chronic renal failure and 24.7% patients were admitted for acute renal failure. Among chronic renal failure patients, 21.9% catheters had to be replaced due to various complications e.g. thrombosis, infection or kinking of the catheter. The subclavian catheters remained in place for a mean duration of 4 weeks. Early complications encountered were arterial puncture, inability to cannulate the innominate vein, hemo thorax, punctures of thoracic duct, hemo mediastinum, arrhythmias and pulmonary hematoma in 10.7%, 16.5%, 0.5%, 0.2%, 0.6% and 0.2% of patients respectively. Mortality attributed to the procedure occurred in 0.1 % cases. Delayed complications included early infection in 15% catheterizations while delayed infection occurred in 39 % cases. Conclusion: Percutaneous subclavian catheterization is valuable, relatively easy to learn and safe method with acceptable rate of complications for patients necessitating hemodialysis and no established permanent vascular access. (author)

  12. Cardiac tamponade and coronary artery pseudoaneurysm after brachial arterial embolectomy, possible role for an aberrant origin of the right coronary artery

    Directory of Open Access Journals (Sweden)

    Irit Stessman-Lande, MD

    2018-03-01

    Full Text Available A patient developed hemopericardium shortly after left brachial arterial embolectomy using an embolectomy catheter. Evaluation disclosed evolving pseudoaneurysm of the right coronary artery that was successfully managed by stenting. Misplacement of the embolectomy catheter within the coronary vessel was facilitated by an anomalous origin of the right coronary artery. This complication highlights the importance of correct insertion of the embolectomy catheter using the markers to avoid maladvancement and damage to central vessels.

  13. Concomitant Avulsion Injury of the Subclavian Vessels and the Main Bronchus Caused by Blunt Trauma.

    Science.gov (United States)

    Noh, Dongsub; Lee, Chan-Kyu; Hwang, Jung Joo; Cho, Hyun Min

    2018-04-01

    Concomitant rupture of the subclavian vessels and the left main bronchus caused by blunt trauma is a serious condition. Moreover, the diagnosis of a tracheobronchial injury with rupture of the subclavian vessels can be difficult. This report describes the case of a 33-year-old man who suffered from blunt trauma that resulted in the rupture of the left subclavian artery and vein. The patient underwent an operation for vascular control. On postoperative day 3, the left main bronchus was found to be transected on a computed tomography scan and bronchoscopy. The transected bronchus was anastomosed in an end-to-end fashion. He recovered without any notable problems. Although the bronchial injury was not detected early, this case of concomitant rupture of the great vessels and the airway was successfully treated after applying extracorporeal membrane oxygenation.

  14. Selective intra-arterial digital subtraction angiography (IADSA) in cerebrovascular disease

    International Nuclear Information System (INIS)

    Uchino, Akira; Satoh, Yoshiyuki; Ohno, Masato

    1987-01-01

    Selective right transbrachial intra-arterial digital subtraction angiography (transbrachial selective IADSA) was successfully performed for 24 of 26 patients with known or suspected cerebrovascular disease, four of whom were outpatients. Catheterization failed in two elderly hypertensive men because of tortuosity of their brachial arteries, and in one woman whose aberrant right subclavian artery (SCA) prevented bilateral common carotid arterial (CCA) catheterizations. No complications occurred. One-hundred and ten ''excellent'' images were obtained by means of 118 injections for the 24 patients. Iopamidol, the contrast medium, was diluted to 50 % concentration with saline, then warmed to 37 deg C. Nearly all the injections of both CCAs and right vertebral arteries (VAs) were completed using 10 ml injections and a 5 ml/sec flow rate. The mean examination time for the three-vessel study was 29.4 minutes. Transbrachial selective IADSA thus proved to be a safe, useful, and relatively easy means of diagnosing cerebrovascular disease. (author)

  15. Significance of MR angiography in the diagnosis of aberrant renal arteries as the cause of ureteropelvic junction obstruction in children; Stellenwert der MR-Angiografie in der Diagnostik aberrierender Nierenarterien als Ursache einer Ureterabgangsstenose bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, L.; Sorge, I.; Hirsch, F.W.; Vieweger, A. [Leipzig Univ. (Germany). Dept. of Pediatric Radiology; Goetz, G.; Lehnert, T.; Buehligen, U.; Geyer, C. [Leipzig Univ. (Germany). Dept. of Pediatric Surgery

    2015-01-15

    To determine the importance of MRI with contrast-enhanced MRA for the detection or exclusion of aberrant or obstructing renal arteries in ureteropelvic junction obstruction in children. Key word-based search in RIS database (ureteropelvic junction obstruction/MRI) and retrospective comparison of arterial findings from preoperative contrast-enhanced MRA and intra-operative inspection. From 2007 to 2013, 19 children with ureteropelvic junction obstruction underwent contrast-enhanced MRA. Based on the results of the MRI scan and MAG3 scintigraphy, the children were referred to surgery (Anderson-Hynes-pyeloplasty). An aberrant renal artery was diagnosed with MRI in 14 of 19 children, and intra-operative inspection confirmed 13 of those 14. In the remaining 5 children, no aberrant vessel could be observed in MRI and this was confirmed intra-operatively in 3 of the 5 cases, while in the remaining 2, an aberrant vessel was found. Of the 14 children with aberrant vessels, 12 underwent surgery due to assumed ureteral obstruction, which was confirmed by surgery in 11 cases. In one case, an aberrant artery was found intra-operatively, but obstruction could not be confirmed. In one of the 14 children, the vessel was found in MRI, but its obstructing character was negated via MRA, which was confirmed intra-operatively. In the diagnosis of aberrant and obstructing renal arteries, contrast-enhanced MRA presents 85 % sensitivity and 80 % specificity, with a positive predictive value of 0.8. MRI with contrast-enhanced MRA is suitable to detect aberrant and obstructing renal arteries. An obstructive effect of the aberrant vessel is to be assumed if the vessel has a close relationship to the ureteropelvic junction and if it is linearly stretched.

  16. Use of ECG-gated computed tomography, echocardiography and selective angiography in five dogs with pulmonic stenosis and one dog with pulmonic stenosis and aberrant coronary arteries.

    Science.gov (United States)

    Laborda-Vidal, P; Pedro, B; Baker, M; Gelzer, A R; Dukes-McEwan, J; Maddox, T W

    2016-12-01

    Pulmonic stenosis (PS) is the most common congenital cardiac disease in dogs. Boxers and English bulldogs are among the most commonly affected breeds and also commonly associated with an aberrant coronary artery (CA). If an aberrant CA is suspected and balloon valvuloplasty indicated, an intra-operative angiography is recommended prior to the procedure. ECG-gated computed tomography (CT) can be used to screen for CA anomalies in a quick and minimally-invasive way (preventing side effects associated with selective catheter angiography) and allowing early planning of the procedure. The aim of this case series was to report CT findings associated with PS diagnosed by echocardiography. Our database was retrospectively searched for cases of dogs with PS diagnosed by echocardiography, where an ECG-gated CT was performed. A total of six cases were retrieved: all were diagnosed with severe PS. Four dogs had concurrent congenital defects: two dogs had a patent ductus arteriosus, one dog had a ventricular septal defect and an overriding aorta, one dog had an aberrant CA. Detailed CT findings of all cases were reported, including one case of a patent ductus arteriosus and an overriding aorta not identified by transthoracic echocardiography. In addition, an abnormal single left coronary ostium, with a pre-pulmonic right CA was described. In conclusion, despite echocardiography remaining the gold standard for diagnosis and assessment of PS, ECG-gated-CT angiography is a complementary diagnostic method that may provide additional relevant information, shorten surgery/anaesthesia time and reduce the amount of radiation to which the clinician is subjected. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Failure of controlling massive hemoptysis in bronchiectasis through BAE due to aberration blood supply from inferior phrenic arteries

    International Nuclear Information System (INIS)

    Liu Fengyong; Duan Feng; Wang Maoqiang; Song Peng; Wang Zhijun; Wang Zhongpu

    2008-01-01

    Objective: To describe the manifestations of the inferior phrenic arterial (IPA) blood supply in hemoptysis of bronchiectasis and to evaluate the safety and efficacy of transcatheter arterial embolization (TAE)of the IPA. Methods: During the past 5 years, 62 patients with hemoptysis due to bronchiectasis underwent BAE including 10 with additional blood supply from IPA. Mean patient age was 42.5 years (range, 26-58 years). Supplemental TAE using gelatin sponge particles and microcoils was undertaken in IPA supplying cases. The imaging findings of the IPA angiography, the predictive factors, the technique and clinical significance including safety of IPA embolization, were evaluated. Results: Selective arteriogram demonstrated enlargement of IPA, with numerous branches and neovasculature in all 10 cases, including contrast material extravasation in 4, and non-specific staining in 6 cases. In addition, there were IPA-to- pulmonary shunting in 8 cases, adjacent to the pleurae involving diaphragmatic and mediastinal pleura in 6 and only mediastinal pleura in 4. Technical success of IPA embolization was achieved in all 10 cases. Embolization of other nonbronchial systemic arteries (the internal thoracic artery in 4 and intercostal artery in 2)were performed at the same session. All bleedings ceased immediately after supplemental IPA embolization. Follow- up ranged from 8 months to 3 years, including mild recurrent hemoptysis in 2 patients at 2, 3 months respectively, but responsible to conservative management and no recurrent bleeding in 8 patients. Conclusion: Bronchiectatic hemoptysis may be further supplied by IPA, resulting in clinical failure of BAE and supplemental TAE of IPA is a safe and effective adjunct to BAE in the management. (authors)

  18. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  19. Throbbing tinnitus in aberrant internal carotid artery aggravated by elevation of the jugular bulb. A case report

    International Nuclear Information System (INIS)

    Wilhelm, T.; Kirsten, R.; Kau, R.J.

    1995-01-01

    Vascular anomalies in the middle ear are rarely observed. They cause no symptoms in the majority of cases, although some may be associated with tinnitus. The false diagnosis of glomus tumour may lead to considerable problems, if surgery is performed. It is therefore necessary that precise pre-operative data are obtained, preferably based on contrast-enhanced computerized tomography. Subsequent 2D and 3D image reconstructions provide further vascular findings regarding the topographic and anatomic factors involved and eliminate the need for invasive angiography of the carotid artery or retrograde jugular venography to make a firm diagnosis. (orig.) [de

  20. Chromosomal aberration

    International Nuclear Information System (INIS)

    Ishii, Yutaka

    1988-01-01

    Chromosomal aberrations are classified into two types, chromosome-type and chromatid-type. Chromosom-type aberrations include terminal deletion, dicentric, ring and interstitial deletion, and chromatid-type aberrations include achromatic lesion, chromatid deletion, isochromatid deletion and chromatid exchange. Clastogens which induce chromosomal aberration are divided into ''S-dependent'' agents and ''S-independent''. It might mean whether they can induce double strand breaks independent of the S phase or not. Double strand breaks may be the ultimate lesions to induce chromosomal aberrations. Caffeine added even in the G 2 phase appeared to modify the frequency of chromatid aberrations induced by X-rays and mitomycin C. Those might suggest that the G 2 phase involves in the chromatid aberration formation. The double strand breaks might be repaired by ''G 2 repair system'', the error of which might yield breakage types of chromatid aberrations and the by-pass of which might yield chromatid exchanges. Chromosome-type aberrations might be formed in the G 1 phase. (author)

  1. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  2. Axillo-axillary Bypass Grafting for Proximal Subclavian Artery ...

    African Journals Online (AJOL)

    1974-10-26

    Oct 26, 1974 ... 'dizzy spells, with tinnitus, which came on without warning and associated with a feeling of syncope. These episodes were usually transient and on occasions were definitely related to rotaton of her neck. Examination showed a weak left radial pulse with a blood pressure of 105/80 mmHg compared with ...

  3. Anatomical Study of Subclavian Artery and Its Branches

    Directory of Open Access Journals (Sweden)

    zahed Safikhani

    2006-02-01

    Conclusion: For preserving the integrity of important structures in the base of the neck, especially thyroid gland in surgery, this vascular variations are presented to physicians to keep in mind that such variations exists during diagnostic investigation and surgical procedures of the neck. An awareness of these variations is important, because this area in used for diagnostic and surgical procedures.

  4. Anomalous Origin of the Subclavian Artery Associated with ...

    African Journals Online (AJOL)

    Thallium, insulin, sulphonamides and other compounds as well as lack of riboflavine produce phocomelia-like malformations in experimental animals while maternal infection such as rubella is teratogenic in humans, but evidence that it causes phocomelia is not well established. Fig. 3. Arteriogram with injection of contrast ...

  5. Radical antegrade modular pancreatosplenectomy for adenocarcinomaof the body of the pancreas in a patient with portal annular pancreas, aberrant hepatic artery, and absence of the celiac trunk: A case report.

    Science.gov (United States)

    Yuan, Hao; Wu, Pengfei; Chen, Jianmin; Lu, Zipeng; Chen, Lei; Wei, Jishu; Guo, Feng; Cai, Baobao; Yin, Jie; Xu, Dong; Jiang, Kuirong; Miao, Yi

    2017-12-01

    Portal annular pancreas is a rare anatomic variation, where the uncinated process of the pancreas connects with the dorsal pancreas and the pancreas tissue encases the portal vein (PV), superior mesenteric vein (SMV) or splenic vein (SV). Malignancies are quite uncommon in the patients, who have an annular pancreas especially portal annular pancreas. Ectopic common hepatic artery and absence of the celiac trunk (CT) are the other infrequent abnormalities. A 74-year-old man suffered from upper abdominal and back pain. Contrast enhanced computed tomography indicated a low-density mass in the body of the pancreas. Pathological report showed adenocarcinoma of the body of pancreas after radical antegrade modular pancreatosplenectomy (RAMPS). In the operation, we found the superior vein and portal vein was surrounded by the pancreatic tissue. The left gastric artery and splenic artery originated respectively from abdominal aorta, and celiac trunk was not viewed. In addition, the common hepatic artery was a branch from the superior mesenteric artery. In general, this is a novel clinical case of pancreatic carcinoma happening in the portal annular pancreas which was accompanied with aberrant hepatic artery and absence of the celiac trunk at the same time. Confronted with the pancreatic neoplasms, the possibility of coexistent annular pancreas and arterial variations should be considered.

  6. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  7. Imaging the vertebral artery

    International Nuclear Information System (INIS)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.

    2005-01-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  8. Subclavian steal syndrome: treatment by percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Abath, Carlos Gustavo Coutinho; Silva, Marcos Antonio Barbosa da; Brito, Norma Maria Tenorio; Marques, Silvio Romero; Santa Cruz, Rodolfo

    1995-01-01

    The subclavian steal syndrome is a rare vascular disease that can be managed by interventional radiology. It is presented the experience with three cases of this syndrome that underwent percutaneous transluminal angioplasty, and a brief literature review is done. Two patients remained asymptomatic 23 and 30 months, respectively, after the procedure. One patient presented with recurrent symptoms 12 months after the dilatation. Considering the low morbidity and good clinical and technical results, percutaneous transluminal angioplasty is the first choice in the subclavian steal syndrome treatment. (author). 9 refs., 3 figs

  9. Influence of Mechanical Ventilation on the Incidence of Pneumothorax During Infraclavicular Subclavian Vein Catheterization: A Prospective Randomized Noninferiority Trial.

    Science.gov (United States)

    Kim, Eugene; Kim, Hyun Joo; Hong, Deok Man; Park, Hee-Pyoung; Bahk, Jae-Hyon

    2016-09-01

    It remains unclear whether we have to interrupt mechanical ventilation during infraclavicular subclavian venous catheterization. In practice, the clinicians' choice about lung deflation depends on their own discretion. The purpose of this study was to assess the influence of mechanical ventilation on the incidence of pneumothorax during infraclavicular subclavian venous catheterization. A total of 332 patients, who needed subclavian venous catheterization, were randomly assigned to 1 of the 2 groups: catheterizations were performed with the patients' lungs under mechanical ventilation (ventilation group, n = 165) or without mechanical ventilation (deflation group, n = 167). The incidences of pneumothorax and other complications such as arterial puncture, hemothorax, or catheter misplacements and the success rate of catheterization were compared. The incidences of pneumothorax were 0% (0/165) in the ventilation group and 0.6% (1/167) in the deflation group. The incidence of pneumothorax in the deflation group was 0.6% higher than that in the ventilation group and the 2-sided 90% confidence interval for the difference was (-1.29% to 3.44%). Because the lower bound for the 2-sided 90% confidence interval, -1.29%, was higher than the predefined noninferiority margin of -3%, the inferiority of the ventilation group over the deflation group was rejected at the .05 level of significance. Other complication rates and success rates of catheterization were comparable between 2 groups. The oxygen saturation dropped below 95% in 9 patients in the deflation group, while none in the ventilation group (P = .007). The success and complication rates were similar regardless of mechanical ventilation. During infraclavicular subclavian venous catheterization, interruption of mechanical ventilation does not seem to be necessary for the prevention of pneumothorax.

  10. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  11. Endovascular Embolization of Bronchial Artery Originating from the Upper Portion of Aortic Arch in Patients with Massive Hemoptysis

    International Nuclear Information System (INIS)

    Jiang, Sen; Sun, Xi-Wen; Yu, Dong; Jie, Bing

    2014-01-01

    PurposeOur experience with endovascular embolization (EVE) of the bronchial artery (BA) originating from the upper portion of the aortic arch (AA) in six patients is described.MethodsAltogether, 818 patients with hemoptysis underwent multidetector row computed tomography angiography (MDCTA) before EVE or AA angiography during EVE. Aberrant BAs originating from the upper portion of the AA were the source of massive hemoptysis in six patients (0.73 %). MDCT angiograms and/or Digital subtraction angiograms were retrospectively reviewed. Selective catheterization and embolization were performed.ResultsThe ostia of the BAs were located on the superior surface of the AA between the brachiocephalic trunk and left common carotid artery in three patients, the junction of the aorta and medial surface of the left subclavian artery in two, and the posterior wall of the upper portion of the AA in one. The six BAs comprised two common trunks, three single right sides, and one single left side. The targeted vessels were successfully catheterized and embolized by a coaxial microcatheter system using polyvinyl alcohol particles. Other pathologic BAs and nonbronchial systemic arteries also were embolized. Bleeding was immediately controlled in all patients with no recurrence of hemoptysis. No procedure-related complications occurred.ConclusionsApplication of EVE of anomalous origin of BAs in patients with hemoptysis is important, as demonstrated in the six reported patients. MDCTA before EVE or AA angiography during EVE is critical to avoid missing a rare aberrant BA originating from the upper portion of the AA

  12. Prediction of subclavian vein location using plain chest radiography.

    Science.gov (United States)

    Fukutome, T; Shigematsu, A

    1986-12-01

    The relationship between the right subclavian vein and the thoracic inlet below the clavicle was studied by Venography in 72 patients. The area of the thoracic inlet below the clavicle was defined as a radiolucent area surrounded superiorly by the lower border of the clavicle, inferiorly by the inner margin of the first rib and medially by the lateral margin of the manubrium (CRM area). In 10 patients, the subclavian vein was situated below the axis of the clavicle, and the CRM area was large enough to extend near the top of the first rib arch. In 62 patients, the subclavian vein extended above the axis of the clavicle and the CRM area was small or invisible. The existence of a large thoracic inlet below the clavicle (large CRM area which extends near the top of the first rib arch) may be a useful indicator for predicting the low location of the subclavian vein, and may be used to predict or explain venipuncture failure using the standard infraclavicular approach.

  13. Suicide by severing the arterio-venous subclavian dialysis catheter.

    Science.gov (United States)

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  14. Subclavian vein aneurysm secondary to a benign vessel wall hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Patrick [Nationwide Children' s Hospital, Section of Pediatric Interventional Radiology, Columbus, OH (United States); Spaeth, Maya [Nationwide Children' s Hospital, Section of Plastic and Reconstructive Surgery, Columbus, OH (United States); Prasad, Vinay [Nationwide Children' s Hospital, Section of Pediatric Pathology, Columbus, OH (United States); McConnell, Patrick [Nationwide Children' s Hospital, Section of Cardiothoracic Surgery, Columbus, OH (United States)

    2013-11-15

    Venous aneurysms are rare clinical entities, particularly in children, and their presentation and natural history often depend on the anatomical location and underlying etiology. We present a single case of a 12-year-old girl who presented with a palpable right supraclavicular mass. Imaging evaluation with CT, conventional venography, MRI and sonography revealed a large fusiform subclavian vein aneurysm with an unusual, mass-like fibrofatty component incorporated into the vessel wall. The girl ultimately required complete resection of the right subclavian vein with placement of a synthetic interposition graft. This case provides a radiology/pathology correlation of an entity that has not previously been described as well as an example of the utility of multiple imaging modalities to aid diagnosis and preoperative planning. (orig.)

  15. Optical Aberrations and Wavefront

    Directory of Open Access Journals (Sweden)

    Nihat Polat

    2014-08-01

    Full Text Available The deviation of light to create normal retinal image in the optical system is called aberration. Aberrations are divided two subgroup: low-order aberrations (defocus: spherical and cylindrical refractive errors and high-order aberrations (coma, spherical, trefoil, tetrafoil, quadrifoil, pentafoil, secondary astigmatism. Aberrations increase with aging. Spherical aberrations are compensated by positive corneal and negative lenticular spherical aberrations in youth. Total aberrations are elevated by positive corneal and positive lenticular spherical aberrations in elderly. In this study, we aimed to analyze the basic terms regarding optic aberrations which have gained significance recently. (Turk J Ophthalmol 2014; 44: 306-11

  16. The arterial supply of the thymus in dogs

    Directory of Open Access Journals (Sweden)

    Frederico Ozanan Carneiro e Silva

    1994-06-01

    Full Text Available There were observed the origin, the number and the ordering of the thymic vessels in 30 dogs fetuses, by dissection after injection with Neoprene latex 450 solution and fixation with formalin solution at 10%. The results permited to conclude that: the thymic arteries come, directly and indirectly, from the internal thoracic arteries, brachiocephalic trunk, pericardicophrenics arteries, costocervicals trunks and subclavian arteries, wich combined by theirself given from five to fourteen contributions that showed a own vascularization model for each organ.

  17. A Case of Duplicated Right Vertebral Artery.

    Science.gov (United States)

    Motomura, Mayuko; Watanabe, Koichi; Tabira, Yoko; Iwanaga, Joe; Matsuuchi, Wakako; Yoshida, Daichi; Saga, Tsuyoshi; Yamaki, Koh-Ichi

    2018-04-27

    We encountered a case of duplicated right vertebral artery during an anatomical dissection course for medical students in 2015. Two vertebral arteries were found in the right neck of a 91-year-old female cadaver. The proximal leg of the arteries arose from the area between the right subclavian artery and the right common carotid artery that diverged from the brachiocephalic artery. The distal leg arose from the right subclavian artery as expected. The proximal leg entered the transverse foramen of the fourth cervical vertebra and the distal leg entered the transverse foramen of the sixth cervical vertebra. The two right vertebral arteries joined to form one artery just after the origin of the right vertebral artery of the brachiocephalic artery entered the transverse foramen of the fourth cervical vertebra. This artery then traveled up in the transverse foramina and became the basilar artery, joining with the left vertebral artery. We discuss the embryological origin of this case and review previously reported cases.

  18. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  19. Subclavian vein thrombosis following fracture of the clavicle: case report

    OpenAIRE

    Terra, Bernardo Barcellos; Cocco, Luiz Fernando; Ejnisman, Benno; Fernandes, Hélio Jorge Alvachian; Reis, Fernando Baldy dos

    2011-01-01

    A trombose venosa profunda no membro superior não é frequente na literatura ortopédica. Relatamos um caso de trombose da veia subclávia durante o tratamento conservador de fratura do terço médio da clavícula. O diagnóstico é difícil e requer um alto grau de suspeição e o tratamento pode prevenir um tromboembolismo fatal. Há raros casos descritos associados à fratura de clavícula.Deep vein thrombosis in the upper limbs is uncommon in the orthopedic literature. We report on a case of subclavian...

  20. Traumatic subclavian arteriovenous fistula in a young adult

    International Nuclear Information System (INIS)

    Nazario Dolz, Ana Maria; Ibannez Casero, Marlene; Rodriguez Fernandez, Zenen; Pichin Quesada, Alexis; Lopez Martin, Jose Carlos

    2011-01-01

    The case report of a 23 year-old patient who was admitted to the General Surgery Service of 'Saturnino Lora Torres' Provincial Teaching Clinical Surgical Hospital in Santiago de Cuba with the diagnosis of traumatic pneumothorax is described, as consequence of stab wounds in the right anterior and superior region of the thorax; but then, after 48 hours, a right subclavian arteriovenous fistula, which was proven by means of x ray was diagnosed. The postoperative clinical course was favorable and the patient was discharged after 11 days, completely asymptomatic. His working activities began 2 months later.(author)

  1. INTERRUPTION OF THE AORTIC-ARCH, DISTAL AORTOPULMONARY WINDOW, ARTERIAL DUCT AND AORTIC ORIGIN OF THE RIGHT PULMONARY-ARTERY IN A NEONATE - REPORT OF A CASE SUCCESSFULLY REPAIRED IN A ONE-STAGE OPERATION

    NARCIS (Netherlands)

    BOONSTRA, PW; EBELS, T

    The case of a 4-day-old male neonate with the rare combination of interruption of the aortic arch beyond the left subclavian artery, distal aortopulmonary window, persistent arterial duct and aortic origin of the right pulmonary artery is presented. Review of the literature reveals this patient to

  2. Abduction of Arm Facilitates Correction of Kinked Peel-Away Sheath During Subclavian Central Line Placement.

    Science.gov (United States)

    Kim, Sunghoon

    2015-12-01

    A tunneled central line catheter placement using a subclavian vein approach can be complicated by an occurrence of peel-away sheath kink which prevents the advancement of the catheter through the sheath. The kink is created due to the angular junction of subclavian and brachiocephalic veins which meet at 90 degree angle. A technique is described which corrects the peel-away sheath kink by extending the subclavian/brachiocephalic vein angle to greater than 90 degrees by abducting the patient's arm. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Internal Thoracic Artery Encircled by an Unusual Phrenic Nerve Loop

    Directory of Open Access Journals (Sweden)

    Robert Fu-Chean Chen

    2007-12-01

    Full Text Available We report an anatomic variation of the phrenic nerve. During a routine gross anatomical dissection course at our medical university, we found an unusual loop of the left phrenic nerve around the internal thoracic artery, about 1 cm from the take-off of the left subclavian artery. The phrenic nerve is close to the internal thoracic artery and is easily injured when dissecting the internal thoracic artery for coronary artery bypass conduit. Therefore, we suggest that the anatomic relationship of the phrenic nerve and internal thoracic artery is important in preventing incidental injury of the phrenic nerve.

  4. Management Strategy for Patients With Chronic Subclavian Vein Thrombosis.

    Science.gov (United States)

    Keir, Graham; Marshall, M Blair

    2017-02-01

    We performed a systematic review to determine best practice for the management of patients with chronic or subacute subclavian vein thrombosis. This condition is best managed with surgical excision of the first rib followed by long-term anticoagulation. Interventional techniques aimed at restoring patency are ineffective beyond 2 weeks postthrombosis. Additional therapeutic options should be made based on the severity of symptoms as well as vein status. Patients with milder symptoms are given decompression surgery followed by anticoagulation whereas patients with more severe symptoms are considered for either a jugular vein transposition or saphenous patch based on the vein characteristics. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Percutaneous transluminal angioplasty (PTA) of supra-aortic arteries especially the internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Kachel, R.; Basche, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Radiologische Klinik); Heerklotz, I.; Grossmann, K. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Innere Medizin); Endler, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Neurologie und Psychiatrie)

    1991-06-01

    We present our experience with 105 patients in whom percutaneous transluminal angioplasty was performed in 112 stenosed or occluded supra-aortic arteries. Symtoms of cerebrovascular and/or vertebrobasilar insufficiency were present in 104 of the 105 patients. The angioplasty was successful in 35 stenoses of the internal carotid artery, 2 stenoses of the common carotid artery, 1 stenosis of the external carotid artery, 15 stenoses of the vertebral artery, 3 stenoses of the innominate artery and 44 stenoses of the subclavian artery. There were only 4 minor-complications (2 haematomas, 1 transient ischemic attack, 1 small thrombus of the internal carotid artery which was detected by 111-indium platelet scintigraphy and treated by thrombendarterectomy before the appearance of neurological symptoms). All patients were symptom free after angioplasty. During the observations period of 3 to 109 months (average 58 months) there were only two cases with re-stenosis after subclavian angioplasty. The results of more than 700 personal and international published percutaneous transluminal angioplasties of supra-aortic arteries are presented. The results suggest that angioplasty of supra-aortic arteries is an effective method. On strict definition of the indications, the complication rate for angioplasty of the supra-aortic arteries is not likely to be higher than that for operative treatment. (orig.).

  6. Combined jugular and subclavian vein thrombosis following assisted reproductive technology--new observation.

    Science.gov (United States)

    Salomon, Ophira; Schiby, Ginette; Heiman, Zehava; Avivi, Kamila; Sigal, Carol; Levran, David; Dor, Jeushua; Itzchak, Yacov

    2009-08-01

    To study the predilection of jugular and subclavian vein thrombosis in patients going through assisted reproductive technology (ART). This technology puts women at high risk of developing the ovarian hyperstimulation syndrome (OHSS) and thrombotic events. Study cases. Large Academic Medical Center. Five women who developed jugular and subclavian vein thrombosis following ART were included in the study. The deep vein thrombosis was demonstrated by ultrasound Doppler or computerized tomography angiography. All women were interviewed and data obtained from outpatient and hospital medical charts. Magnetic resonance imaging and complete thrombophilic profile workup was performed in each woman. Open biopsy from the lesions was taken from one of the women. Correlation between mechanical branchial cysts filled with fluid during OHSS and jugular and subclavian vein thrombosis. Five women developed jugular and subclavian vein thrombosis following ART. They were found to harbor clusters of rudimentary branchial cysts filled with fluid at the time of OHSS, which compressed the jugular and subclavian veins at their junction at the base of the neck. Four patients (80%) were found to be carriers of factor V Leiden. Predilection of jugular and subclavian vein thrombosis early in pregnancy is the result of mechanical compression mediated by rudimentary branchial cysts filled with fluid during OHSS, particularly in subjects who are carriers of factor V Leiden.

  7. Hemodynamic effects of innominate artery occlusive disease on anterior cerebral artery.

    Science.gov (United States)

    Tan, Teng-Yeow; Lien, Li-Ming; Schminke, Ulf; Tesh, Paul; Reynolds, Patrick S; Tegeler, Charles H

    2002-01-01

    Stenoses of the innominate artery (IA) may affect flow conditions in the carotid arteries. However, alternating flow in ipsilateral anterior cerebral artery (ACA) due to IA stenosis is extremely rare. A 49-year-old woman who was evaluated for symptomatic cerebrovascular disease presented with right latent subclavian and right carotid system steal. Transcranial Doppler examination displayed systolic deceleration wave-forms in the right terminal internal carotid artery and alternating flow in the right ACA. Magnetic resonance angiography demonstrated tight stenosis of the right IA. For a thorough study of the hemodynamic effects of IA stenosis, a combination of duplex and transcranial Doppler examination is required.

  8. Arterial supply of the thoracic lobes of the thymus in dogs of the Great Dane race.

    Directory of Open Access Journals (Sweden)

    Rosana Marques Silva

    2007-09-01

    Full Text Available The origins, numbers and type of arterial branches responsible for the blood supply of thoracic lobes of the thymus were studied in 28 stillborn dogs of the Great Dane, of which 18 were males and 10 were females. The arterial systems of these animals were filled with aqueous solution of Neoprene Latex “450”, 50%. After, the specimens were fixed in 10% formaldehyde aqueous solution. The lobes of the thymus were supplied by direct or indirect arterial branches coming from the right and left internal thoracic arteries, pericardiacophrenicas arteries, right and left costocervicais trunks, and left subclavian artery. The left subclavian artery and brachiocephalic trunk emitted direct branches towards the left thoracic lobe of the thymus.

  9. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  10. Subclavian Vein Stenosis/Occlusion Following Transvenous Cardiac Pacemaker and Defibrillator Implantation: Incidence, Pathophysiology and Current Management

    Directory of Open Access Journals (Sweden)

    Brian O'Leary

    2015-08-01

    Full Text Available Subclavian vein stenosis is a common, but usually asymptomatic, complication following cardiac device placement. In addition to reviewing the literature on incidence, pathogenesis and management options for this important clinical problem, we describe two cases of symptomatic subclavian vein occlusion following pacemaker/defibrillator placement and successful treatment with venoplasty and stenting.

  11. FEATURES OF FORMATION OF COLLATERAL CIRCULATION IN PATIENTS WITH SUBCLAVIAN STEAL SYNDROME.

    Science.gov (United States)

    Kopolovets, I; Štefanič, P; Rusyn, V; Tóth, Š; Mashura, V; Berek, P

    2017-12-01

    To date in patients with subclavian steal syndrome diagnosis is only grade of stenosis or localization of occlusion described. Authors recommend to take into account also type of a collateral compensation of cerebral circulation for selection of an optimal treatment The objective of the research was to study the features of formation of collateral circulation in patients with subclavian steal syndrome. The authors described changes in the direction of blood flow in the extracranial vessels of 42 patients with subclavian steal syndrome. Latent subclavian steal syndrome was detected in 26.2% of patients, transient subclavian steal syndrome was found in 54.8% of patients, and a persistent course of the disease was observed in 19.9% of patients. Symptoms of vertebrobasilar insufficiency were detected in 26.6% of patients, and combination of chronic upper extremity ischemia and vertebrobasilar insufficiency was diagnosed in 73.8% of patients. When analyzing the features of collateral circulation in 64.3% of patients the extracranial compensatory mechanism was observed being provided by three main groups of collateral hemodynamic reallocation: the occipito-vertebral hemodynamic mechanism of compensation was detected in 38.1% of cases, the thyroid compensatory mechanism was found in 16.7% of cases, and the brain stem-occipital compensatory mechanism was observed in 9.5% of cases. In 35.7% of patients the intracranial compensatory mechanism was observed being provided by two main groups of collateral hemodynamic reallocation: the vertebro-vertebral compensatory mechanism was found in 21.4% of cases and cerebrobasilar compensatory mechanism was detected in 14.3% of cases. Consideration of the features of collateral circulation in patients with subclavian steal syndrome may serve as a prognostic criterion for selecting an optimal treatment tactics.Each of compensatory mechanisms has its own hemodynamic peculiarities. The occipito- vertebral compensatory mechanism has the

  12. Permanent Cortical Blindness After Bronchial Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Doorn, Colette S. van, E-mail: cvandoorn@gmail.com; De Boo, Diederick W., E-mail: d.w.deboo@amc.uva.nl [Academic Medical Centre, Department of Radiology (Netherlands); Weersink, Els J. M., E-mail: e.j.m.weersink@amc.uva.nl [Academic Medical Centre, Department of Pulmonology (Netherlands); Delden, Otto M. van, E-mail: o.m.vandelden@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl; Lienden, Krijn P. van, E-mail: k.p.vanlienden@amc.uva.nl [Academic Medical Centre, Department of Radiology (Netherlands)

    2013-12-15

    A 35-year-old female with a known medical history of cystic fibrosis was admitted to our institution for massive hemoptysis. CTA depicted a hypertrophied bronchial artery to the right upper lobe and showed signs of recent bleeding at that location. Bronchial artery embolization (BAE) was performed with gelfoam slurry, because pronounced shunting to the pulmonary artery was present. Immediately after BAE, the patient developed bilateral cortical blindness. Control angiography showed an initially not opacified anastomosis between the embolized bronchial artery and the right subclavian artery, near to the origin of the right vertebral artery. Cessation of outflow in the bronchial circulation reversed the flow through the anastomosis and allowed for spill of embolization material into the posterior circulation. Unfortunately the cortical blindness presented was permanent.

  13. Angioplasty in stenosis of the innominate artery

    International Nuclear Information System (INIS)

    Kobinia, G.S.; Bergmann, H. Jr.

    1983-01-01

    We describe a successful percutaneous transluminal dilatation (PTD) of an innominate artery stenosis in a 40-year-old patient with aortic arch syndrome. Five years earlier both a left central carotid artery occlusion and an innominate and left subclavian artery stenosis were treated by grafting from the aorta to the distal vessels. At recurrence of the neurological symptoms, reocclusion of the graft to the innominate artery and subtotal stenosis of the left carotid anastomosis were noted. The prevent the hazards of a reoperation, the innominate artery stenosis was dilated by means of PTD via the right brachial artery. Success of the procedure was demonstrated by Doppler sonography and angiography. It appears that PTD serves as an excellent method of treating stenoses of the aortic arch branches in aortic arch syndrome. (orig.)

  14. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  15. Incidentally diagnosed Takayasu arteritis on thyroid ultrasonography showing prominent collateral vessels of thyroidal arteries and common carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Se Jin; Kim, Eun Kyung [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    We report a case of middle-aged woman incidentally diagnosed with Takayasu arteritis during the ultrasonography of a thyroid gland nodule. Prominent collaterals of the thyroidal arteries and a thin common carotid artery with mural thickening and deficient intraluminal flow signals were initially depicted on the ultrasonography with color Doppler. Subsequent magnetic resonance angiography and computed tomography aortography confirmed the diagnosis with the imaging features of a bilateral long segment common carotid artery occlusion and segmental stenosis of the left subclavian artery in addition to the suggestive physical findings.

  16. Pseudoaneurysms of large arteries associated with AIDS

    Directory of Open Access Journals (Sweden)

    Carlos Eli Piccinato

    Full Text Available BACKGROUND: Several vascular complications are known to occur in association with the acquired immunodeficiency syndrome (AIDS and recent publications have called attention to the development of pseudoaneurysms of large arteries in patients with AIDS. CASE REPORT: We report on 2 patients with AIDS aged 23 and 31 years with pseudoaneurysms of the abdominal aorta and common iliac arteries. After clinical and radiological evaluation by arteriography and computed tomography, the patients were submitted to aneurysmectomy, with the placement of a patch of dacron in the first case and the interposition of a right aorto-iliac and left femoral prosthesis in the second. The second patient developed new aneurysms of the right subclavian and left popliteal arteries 2 months after surgery. Proximal ligation of the right subclavian artery was performed to treat the first aneurysm and resection and interposition of a reversed saphenous vein was carried out to treat the pseudoaneurysm of the popliteal artery. Histopathological examination of the popliteal artery revealed necrotizing arteritis.

  17. Endo-aneurysmorrhaphy of a giant aneurysm of the subclavian vein

    Directory of Open Access Journals (Sweden)

    Ahmed Afifi

    2012-07-01

    Full Text Available Venous aneurysms are relatively rare anomalies which can affect different parts of the vascular system. Diagnosis and management of this condition could pose important problems. We here report a giant false aneurysm of the subclavian vein with emphasis on the thought process that determined the management strategy.

  18. Surgical treatment for the subclavian steal syndrome. Surgical indication and selection of procedures by {sup 123}I-IMP-SPECT imaging and {sup 99m}Tc-HSA accumulation curve in upper extremities

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Toyohisa; Tokunaga, Hidemori; Akita, Nobuhisa; Nonaka, Masahiro [Saiseikai Chuwa Hospital, Sakurai, Nara (Japan)

    1998-03-01

    To select reasonable operative procedures in the respective patients, we have studied the cerebral blood flow, especially in the posterior circulation, by {sup 123}I-IMP-SPECT imaging, and the blood flow in the upper extremities by {sup 99m}Tc-HSA accumulation curve in 11 patients with subclavian steal syndrome. Although all patients presented distinct symptoms and signs of vertebrobasilar insufficiency, {sup 123}I-IMP-SPECT early image demonstrated no evident finding of decreased blood flow in the posterior circulation. However, in the delayed image 5 out of 11 patients revealed laterality of IMP uptake in cerebellar hemisphere. Four patients presented symptoms of the upper extremities including arm claudication, and all of them revealed {sup 99m}Tc-HSA accumulation curve indicated decreased blood flow in the affected side of arm and forearm. We performed transposition of vertebral artery to common carotid artery in 7 patients without evidence of decreased blood flow in the upper extremities by {sup 99m}Tc-HSA accumulation curve, common carotid-subclavian dacron graft bypass in 3 cases with evidence of decreased blood flow in the upper extremities, and arch aorta-common carotid dacron graft bypass for the innominate artery occlusion. When the ischemia in the anterior circulation had existed in patients with multiple cerebrovascular occlusive disease, we first corrected the anterior circulation, and then performed the revascularization for the posterior circulation mentioned above by staged operation, resulting in successful treatment of all patients. (K.H.)

  19. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.

    Science.gov (United States)

    Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun

    2016-01-01

    Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.

  20. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  1. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  2. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  3. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli, A.P. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: Andreas.Chemelli@i-med.ac.at; Chemelli-Steingruber, I.E. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria); Bonaros, N. [Department of Cardiovascular Surgery, Innsbruck Medical University (Austria); Luckner, G. [Department of Anaesthesiology and Critical Care Medicine, Innsbruck Medical University (Austria); Millonig, G. [Department of Gastroenterology and Hepatology, Innsbruck Medical University (Austria); Seppi, K. [Department of Neurology, Innsbruck Medical University (Austria); Lottersberger, C.; Jaschke, W. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)

    2009-08-15

    Purpose: This study describes several cases of endovascular coil embolization of the proximal internal mammary artery injured by blind approach to the subclavian vein for central venous catheter or pacemaker lead insertion. Materials and methods: We conducted a retrospective analysis of five patients with iatrogenic arterial lesions of the internal mammary artery (IMA). The lesions occurred in three patients from a puncture of the subclavian vein during insertion of a central venous catheter and in two patients from a puncture of the subclavian vein for insertion of a pacemaker lead. Four patients had acute symptoms of bleeding with mediastinal hematoma and hematothorax and one patient was investigated in a chronic stage. A pseudoaneurysm was detected in all five patients. All four acute and hemodynamic unstable patients required hemodynamic support. Results: In all patients, embolization was performed using a coaxial catheter technique, and a long segment of the IMA adjacent distally and proximally to the source of bleeding was occluded with pushable microcoils. In one patient, additional mechanically detachable microcoils were used at the very proximal part of the IMA. Microcoil embolization of the IMA was successful in all patients, and the source of bleeding was eliminated in all patients. Conclusion: Transarterial coil embolization is a feasible and efficient method in treating acute bleeding and pseudoaneurysm of the IMA and should be considered if mediastinal hematoma or hemathorax occurs after blind puncture of the subclavian vein.

  4. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    Directory of Open Access Journals (Sweden)

    Vedran Premuzic

    2018-01-01

    Full Text Available Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous catheter for hemodialysis in left subclavian vein, he developed lymph leakage on puncture site beside the catheter, at drainage rate of 75 ml/h. In the absence of more serious clinical symptoms, conservative treatment with close patient monitoring and diet changes was chosen, rather than more invasive treatment options.

  5. Mutations and chromosomal aberrations

    International Nuclear Information System (INIS)

    Kihlman, B.A.

    1977-01-01

    The genetic changes of mutations and chromosomal aberrations are discussed. The consequences of both depend not only on the type of genetic change produced but also on the type of cell that is affected and on the development stage of the organism. (C.F.)

  6. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    OpenAIRE

    Vedran Premuzic; Ranko Smiljanic; Drazen Perkov

    2018-01-01

    Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED) with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous c...

  7. Internal Jugular and Subclavian Vein Thrombosis in a Case of Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Hiroto Moriwaki

    2017-01-01

    Full Text Available Central venous catheter insertion and cancer represent some of the important predisposing factors for deep venous thrombosis (DVT. DVT usually develops in the lower extremities, and venous thrombosis of the upper extremities is uncommon. Early diagnosis and treatment of deep venous thrombosis are of importance, because it is a precursor of complications such as pulmonary embolism and postthrombotic syndrome. A 47-year-old woman visited our department with painful swelling on the left side of her neck. Initial examination revealed swelling of the region extending from the left neck to the shoulder without any redness of the overlying skin. Laboratory tests showed a white blood cell count of 5,800/mm3 and an elevated serum C-reactive protein of 4.51 mg/dL. Computed tomography (CT of the neck revealed a vascular filling defect in the left internal jugular vein to left subclavian vein region, with the venous lumina completely occluded with dense soft tissue. On the basis of the findings, we made the diagnosis of thrombosis of the left internal jugular and left subclavian veins. The patient was begun on treatment with oral rivaroxaban, but the left shoulder pain worsened. She was then admitted to the hospital and treated by balloon thrombectomy and thrombolytic therapy, which led to improvement of the left subclavian venous occlusion. Histopathologic examination of the removed thrombus revealed adenocarcinoma cells, indicating hematogenous dissemination of malignant cells.

  8. Contemporary management of civilian penetrating cervicothoracic arterial injuries.

    Science.gov (United States)

    Weinberg, Jordan A; Moore, Andrew H; Magnotti, Louis J; Teague, Rebecca J; Ward, Tyler A; Wasmund, Joshua B; Lamb, Elena M P; Schroeppel, Thomas J; Savage, Stephanie A; Minard, Gayle; Maish, George O; Croce, Martin A; Fabian, Timothy C

    2016-08-01

    The management of arterial injury at the thoracic outlet has long hinged on the fundamental principles of extensile exposure and vascular anastomosis. Nonetheless, treatment options for such injuries have evolved to include both endovascular stent placement and temporary vascular shunts. The purpose of this study was to evaluate our recent experience with penetrating cervicothoracic arterial injuries in light of these developments in trauma care. Patients with penetrating injuries to the innominate, carotid, subclavian, or axillary arteries managed at a single civilian trauma center between 2000 and 2013 were categorized as the modern era (ME) cohort. The management strategies and outcomes pertaining to the ME group were compared to those of previously reported experience (PE) concerning injuries to the innominate, carotid, subclavian, or axillary arteries at the same institution from 1974 to 1988. Over the two eras, there were 202 patients: 110 in the ME group and 92 in the PE group. Most of the injuries in both groups were managed with primary repair (45% vs. 46%; p = 0.89). A similar proportion of injuries in each group was managed with anticoagulation alone (14% vs. 10%; p = 0.40). In the ME group, two cases were managed with temporary shunt placement, and endovascular stent placement was performed in 12 patients. Outcomes were similar between the groups (bivariate comparison): mortality (ME, 15% vs. PE, 14%; p = 0.76), amputation following subclavian or axillary artery injury (ME, 5% vs. PE, 4%; p = 0.58), and posttreatment stroke following carotid injury (ME, 2% vs. PE, 6%; p = 0.57). Experience with penetrating arterial cervicothoracic injuries at a high-volume urban trauma center remained remarkably similar with respect to both anatomic distribution of injury and treatment. Conventional operative exposure and repair remain the cornerstone of treatment for most civilian cervicothoracic arterial injuries. Therapeutic study, level V.

  9. Retrograde Embolization of the Left Vertebral Artery in a Type II Endoleak After Endovascular Treatment of Aortic Thoracic Rupture: Technical Note

    International Nuclear Information System (INIS)

    Rabellino, Martin; Garcia Nielsen, L.; Baldi, S.; Zander, T.; Arnaiz, L.; Llorens, R.; Zerolo, I.; Maynar, M.

    2009-01-01

    Endoleak is a frequent complication after endovascular repair of aortic rupture. We describe the case of a female patient with traumatic aortic injury, treated with endograft, who developed a type II endoleak through the left subclavian and vertebral arteries. Both arteries originated independently from the aortic arch, and were managed with coil embolization of each vessel. We also report our experience with treating the left vertebral artery by placing a microcatheter through the right vertebral one.

  10. Optical traps with geometric aberrations

    International Nuclear Information System (INIS)

    Roichman, Yael; Waldron, Alex; Gardel, Emily; Grier, David G.

    2006-01-01

    We assess the influence of geometric aberrations on the in-plane performance of optical traps by studying the dynamics of trapped colloidal spheres in deliberately distorted holographic optical tweezers. The lateral stiffness of the traps turns out to be insensitive to moderate amounts of coma, astigmatism, and spherical aberration. Moreover holographic aberration correction enables us to compensate inherent shortcomings in the optical train, thereby adaptively improving its performance. We also demonstrate the effects of geometric aberrations on the intensity profiles of optical vortices, whose readily measured deformations suggest a method for rapidly estimating and correcting geometric aberrations in holographic trapping systems

  11. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  12. Aberrant PO2 values in proficiency testing.

    Science.gov (United States)

    Fonzi, C E; Clausen, J L; Mahoney, J

    1993-03-01

    We prospectively determined the frequency of aberrant vials of fluorocarbon/buffer used for proficiency testing of measurements of pH, PCO2, and PO2, using 20 duplicate vials from 12 lots of fluorocarbon/buffer and two arterial blood gas analyzers in eight reference laboratories. We defined aberrant vials as vials for which both duplicate measurements differed from the mean value of repeated measurements for the specific instrument (for each lot of testing materials) by > 0.04 for pH, > 10% of the mean or 3.0 mm Hg, whichever was greater, for PCO2; or > 10% of the mean or 6 mm Hg, whichever was greater, for PO2. Four of 1620 vials (0.25%) were aberrant, all based on PO2 measurements (range of mean values: pH, 7.181-7.631; PCO2, 12.7-65.9; PO2, 32.5-150.1) were 0.0055 for pH, 0.67 mm Hg for PCO2, and 1.65 mm Hg for PO2. Deliberate contamination of the fluorocarbon emulsion with room air, as might occur during sampling from the vial, indicated that only minor increases in PO2 (e.g., 1.0 mm Hg at PO2 of 56 mm Hg) occur when samples are aspirated. Larger increases in PO2 (mean 7.1 mm Hg at a PO2 of 66 mm Hg) occurred when the syringe samples were contaminated with room air. We conclude that isolated aberrant measurements of PO2 in blood gas proficiency testing attributable to vial contents can occur, but the frequency is very low.

  13. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  14. Focal hot spot induced by a central subclavian line on bone scan.

    Science.gov (United States)

    Moslehi, Masood; Cheki, Mohsen; Dehghani, Tohid; Eftekhari, Mansoureh

    2014-01-01

    The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal) variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration) and the interpreting physicians should be aware of the impact of technical factors on image quality.

  15. Aberration studies and computer algebra

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    1981-01-01

    The labour of calculating expressions for aberration coefficients is considerably lightened if a computer algebra language is used to perform the various substitutions and expansions involved. After a brief discussion of matrix representations of aberration coefficients, a particular language, which has shown itself to be well adapted to particle optics, is described and applied to the study of high frequency cavity lenses. (orig.)

  16. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  17. Anomalous Origin of the Left Vertebral Artery from the Aortic Arch.

    Science.gov (United States)

    Einstein, Evan H; Song, Linda H; Villela, Natalia L A; Fasani-Feldberg, Gregory B; Jacobs, Jonathan L; Kim, Dolly O; Nathawat, Akshay; Patel, Devika; Bender, Roger B; Peters, Daniel F

    2016-04-01

    Anatomic anomalies of the aortic arch have implications for clinical practice if their significance is understood. Our case study involves a cadaveric finding of the left vertebral artery originating directly from the aortic arch. Although this anatomical variation has been documented, the prevalence of this anomaly may be generally underestimated. After noting this anomaly, we analyzed 27 cases and found that four female cadavers had the left vertebral artery originating from the aortic arch rather than the left subclavian artery. With a prevalence rate of 14.8%, it would seem that this anomaly is more significant than previously thought, which could have implications for surgical practice.

  18. A systematic study of the brain base arteries in the rabbit (Oryctolagus cuniculus

    Directory of Open Access Journals (Sweden)

    Fernanda de Souza

    2013-06-01

    Full Text Available The brains of 30 New Zealand rabbits (Oryctolagus cuniculus were injected with red stained latex. The arteries of the ventral surface of the brain were systematized on the right (R and on the left (L side with the respective percentage of appearance: the aortic arch emitted the braquicephalic trunk and the left subclavian artery (83.3%; or the braquicephalic trunk, the left common carotid artery and the left subclavian artery (16.7%. The braquicephalic trunk emitted the right and the left common carotid arteries and the right subclavian artery (83.3%; or the right common carotid artery and the right subclavian artery (16.7%. The common carotid arteries were divided into external and internal carotid arteries (96.7% on the R, 100% on the L.. The internal carotid artery to the R was present (96.7% and absent (3.3%, and to the L, was present (100%. The rostral choroidal artery to the R was collateral branch of the rostral branch of the internal carotid artery (83.3%, collateral branch of caudal branch of the internal carotid artery (16.7%, and to the L was collateral branch of the rostral branch of the internal carotid artery (93.3%, collateral branch of the caudal branch of the internal carotid artery (6.7%. The middle cerebral artery to the R and to the L was single (80% and double (20%. The rostral cerebral artery to the R had middle caliber (90%, thin caliber (6.7% and too thin caliber (3.3%, and to the L had middle caliber (76.7%, thin caliber (16.7% and too thin caliber (6.7%. The internal ethmoidal artery was absent (73.3%, present and single (26.7%. The caudal cerebral artery to the R was single (66.7%, double (26.7% and triple (6.7%, and to the L was single (63.3% and double (36.7%. The terminal branches of the right and left vertebral arteries were present (100%, and formed the basilar artery (100%. The ventral spinal artery was present (100%. The caudal cerebellar artery, to the R was single (43.3%, single with labyrinthic artery

  19. Camera processing with chromatic aberration.

    Science.gov (United States)

    Korneliussen, Jan Tore; Hirakawa, Keigo

    2014-10-01

    Since the refractive index of materials commonly used for lens depends on the wavelengths of light, practical camera optics fail to converge light to a single point on an image plane. Known as chromatic aberration, this phenomenon distorts image details by introducing magnification error, defocus blur, and color fringes. Though achromatic and apochromatic lens designs reduce chromatic aberration to a degree, they are complex and expensive and they do not offer a perfect correction. In this paper, we propose a new postcapture processing scheme designed to overcome these problems computationally. Specifically, the proposed solution is comprised of chromatic aberration-tolerant demosaicking algorithm and post-demosaicking chromatic aberration correction. Experiments with simulated and real sensor data verify that the chromatic aberration is effectively corrected.

  20. Percutaneous angioplasty of carotid artery stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, G.; Freitag, J.; Koch, R.D.; Wagemann, W.

    1986-03-01

    Percutaneous transluminal angioplasty (PTA) is a well-established method to remedy stenoses and short occlusions in the femoro-popliteal region and has also proved worthwhile in dilating stenoses of pelvic, renal and coronary arteries. Following successful experiments in animals, Mathias et al. employed angioplasty to treat carotid artery stenoses in the same way. To date, successful treatment of carotid artery stenoses has been described only in isolated recent reports. For fear of embolism, angioplasty has not yet become standard practice in this region. Because of the limited number of carotid artery stenoses treated so far, the risk involved cannot be reliably assessed. It is remarkable that no embolism has been reported for the greater number of dilated stenoses of the subclavian artery. Moreover, the report by Mathias et al. indicated that for 350 angioplasties of pelvifemoral arteries 1.1% embolisms occured after artery occlusions only, while no embolism was observed after stenoses. Having gained experience of applying PTA to the treatment of vascular obstructions of extremities, we have adopted this technique in the carotid area as well.

  1. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    Science.gov (United States)

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  2. Is guidewire exchange a better approach for subclavian vein re-catheterization for chronic hemodialysis patients?

    Science.gov (United States)

    Hou, Shaw-Min; Chou, Po-Ching; Huang, Chi-Hung; Chin, Chih-Hui; Wang, Pa-Chun; Chen, Ya-Hui

    2006-01-01

    The objectives of this study were to compare outcomes and survival rates of subclavian vein re-catheterization through guide wire exchange (GWE) or de novo insertion (DN). The study was conducted in a retrospective manner. Medical records of 36 patients who received percutaneous subclavian vein re-catheterization for hemodialysis in our institution during the period from April 1, 2001 to September 30, 2004 were reviewed. All patients had at least 2 catheter insertions records in our institute. Incidences of adverse events (infection, thrombosis) were compared between GWE and DN groups using x2 test. Predictors for adverse event occurrences were analyzed using logistic regression models. Cox proportional hazard model was used to investigate the predictors for adverse event-free catheter days. Kaplan-Meire survival curves were computed and compared using log rank test. Information were generated from 98 catheters (41 from DN, 57 from GWE groups). The average catheter usage was 2.8+/-0.9 devices per patient and the mean catheter-indwelling-day was 125.4+/-129.5 days in this cohort. We found GWE group had significantly lower thrombosis rate (49.1% vs. 85.4% for DN group, Prates for GWE were > or =30 days, 85.4%; > or =60 days, 75.5%; > or =90 days, 64.5%; > or =180 days, 44.3%. The actuarial survival rates for DN were > or =30 days, 70.7%; > or =60 days, 58.5%; > or =90 days, 34.2%; > or =180 days, 18.4%. GWE group catheters had significantly higher catheter survival rates (P=0.0009). Mahukar catheter (hazard ratio 0.514, P=0.03), non-shock (hazard ratio 3.358, P=0.04), and older age (hazard ratio 0.958, P=0.026) were predictors of adverse event-free remaining catheter days. We suggest that GWE might be a favorable option over DN insertion when revised subclavian vein catheterization is inevitable. GWE can be performed repeatedly without compromising catheter outcomes.

  3. Throbbing tinnitus in aberrant internal carotid artery aggravated by elevation of the jugular bulb. A case report; Pulsierender Tinnitus bei aberranter Arteria carotis interna in Kombination mit Hochstand des Bulbus venae jugularis. Kasuistik

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, T [Inst. fuer Roentgendiagnostik, Klinikum der Technischen Univ. Muenchen (Germany); Kirsten, R [Inst. fuer Roentgendiagnostik, Klinikum der Technischen Univ. Muenchen (Germany); Kau, R J [Hals-Nasen-Ohrenklinik und Poliklinik, Klinikum der Technischen Univ. Muenchen (Germany)

    1995-04-01

    Vascular anomalies in the middle ear are rarely observed. They cause no symptoms in the majority of cases, although some may be associated with tinnitus. The false diagnosis of glomus tumour may lead to considerable problems, if surgery is performed. It is therefore necessary that precise pre-operative data are obtained, preferably based on contrast-enhanced computerized tomography. Subsequent 2D and 3D image reconstructions provide further vascular findings regarding the topographic and anatomic factors involved and eliminate the need for invasive angiography of the carotid artery or retrograde jugular venography to make a firm diagnosis. (orig.) [Deutsch] Gefaessanomalien im Mittelohr sind selten. Meist sind sie asymptomatisch, koennen aber assoziiert sein mit Tinnitus. Die Fehldiagnose eines Glomustumors kann im Rahmen einer Operation zu gravierenden Problemen fuehren. Eine exakte praeoperative Abklaerung ist deshalb notwendig und sollte als Computertomographie mit Kontrastmittelgabe durchgefuehrt werden. Die anschliessende 2D- und 3D-Bildwiedergabe klaert die topographisch-anatomischen Gefaessbeziehungen und erlaubt somit die Diagnosestellung ohne die frueher durchgefuehrte invasive Carotisangiographie oder retrograde Jugularisvenographie. (orig.)

  4. Ultrasound-Guided Cannulation: Time to Bring Subclavian Central Lines Back

    Directory of Open Access Journals (Sweden)

    Talayeh Rezayat, DO, MPH

    2016-03-01

    Full Text Available Despite multiple advantages, subclavian vein (SCV cannulation via the traditional landmark approach has become less used in comparison to ultrasound (US guided internal jugular catheterization due to a higher rate of mechanical complications. A growing body of evidence indicates that SCV catheterization with real-time US guidance can be accomplished safely and efficiently. While several cannulation approaches with real-time US guidance have been described, available literature suggests that the infraclavicular, longitudinal “in-plane” technique may be preferred. This approach allows for direct visualization of needle advancement, which reduces risk of complications and improves successful placement. Infraclavicular SCV cannulation requires simultaneous use of US during needle advancement, but for an inexperienced operator, it is more easily learned compared to the traditional landmark approach. In this article, we review the evidence supporting the use of US guidance for SCV catheterization and discuss technical aspects of the procedure itself.

  5. Isolated Unilateral Absent Branch Pulmonary Artery with Peripheral Pulmonary Stenosis and Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Sunil Abhishek B

    2017-09-01

    Full Text Available Isolated Unilateral Absent Pulmonary Artery (UAPA is a rare congenital anomaly. It is usually associated with congenital heart defects. A 45 year old male patient presented with complaints of fever with cough and expectoration for 15 days and retrosternal chest discomfort for the previous 2 days. ECG showed diffuse ST segment depression with T wave inversion in the inferior and lateral leads. Coronary Angiogram done through the right femoral approach revealed diffusely diseased Left Anterior Descending (LAD artery that was totally cut off at the mid segment. The Left Circumflex (LCx artery was providing blood supply to the right middle and lower lung areas. There was another collateral arising from the Left Subclavian Artery supplying the right middle and lower lung areas. The left pulmonary artery was normal, but branches supplying the middle and lower lobes of the right lung were absent and the upper lobe branch had pulmonary stenosis. UAPA is a rare clinical entity; collaterals from coronaries are extremely rare in this condition and till now there has not been any case report of unilateral absent branch pulmonary artery with peripheral stenosis of other branches, on the affected side and associated coronary artery disease.

  6. Right Hepatic Artery: A Cadaver Investigation and Its Clinical Significance

    Directory of Open Access Journals (Sweden)

    Usha Dandekar

    2015-01-01

    Full Text Available The right hepatic artery is an end artery and contributes sole arterial supply to right lobe of the liver. Misinterpretation of normal anatomy and anatomical variations of the right hepatic artery contribute to the major intraoperative mishaps and complications in hepatobiliary surgery. The frequency of inadvertent or iatrogenic hepatobiliary vascular injury rises with the event of an aberrant anatomy. This descriptive study was carried out to document the normal anatomy and different variations of right hepatic artery to contribute to existing knowledge of right hepatic artery to improve surgical safety. This study conducted on 60 cadavers revealed aberrant replaced right hepatic artery in 18.3% and aberrant accessory right hepatic artery in 3.4%. Considering the course, the right hepatic artery ran outside Calot’s triangle in 5% of cases and caterpillar hump right hepatic artery was seen in 13.3% of cases. The right hepatic artery (normal and aberrant crossed anteriorly to the common hepatic duct in 8.3% and posteriorly to it in 71.6%. It has posterior relations with the common bile duct in 16.7% while in 3.4% it did not cross the common hepatic duct or common bile duct. The knowledge of such anomalies is important since their awareness will decrease morbidity and help to keep away from a number of surgical complications.

  7. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    Science.gov (United States)

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  8. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  9. Ultrasound-guided catheterization of the left subclavian vein without recognition of persistent left superior vena cava

    OpenAIRE

    Park, Sun Young; Yoo, Jae Hwa; Kim, Mun Gyu; Kim, Sang Ho; Park, Byoung-Won; Oh, Hong Chul; Kim, Hojoon

    2017-01-01

    Abstract Rationale: A persistent left superior vena cava (PLSVC) is rare, but the most common thoracic venous anomaly. We report a case of PLSVC unrecognized during left subclavian vein catheterization using real-time ultrasound-guided supraclavicular approach. Patient concerns: A 79-year-old man with history of hypertension presented with traumatic subdural hemorrhage, subarachnoid hemorrhage, and epidural hemorrhage. Before the operation, a central venous catheter (CVC) was placed into the ...

  10. The effect of lung deflation on the position and size of the subclavian vein in mechanically ventilated infants and children.

    Science.gov (United States)

    Lim, Kyung-Jee; Kim, Jin-Tae; Kim, Hee-Soo; Byon, Hyo-Jin; Lee, Soo-Kyung; Lee, Jung-Man

    2011-06-01

    If lung deflation increases the distance from the subclavian vein (SCV) to the pleura and the diameter of the vein, it might decrease the risk of pneumothorax and increase the success rate of subclavian venous cannulation. We evaluated the effect of lung deflation on the distance from the SCV to the pleura (SCV-pleura distance) and on the cross-sectional area (CSA) of the SCV in mechanically ventilated pediatric patients. Fifty patients (25 infants younger than 1 year and 25 children aged 1 to 8 years) were placed supine over a shoulder roll, and their lungs were ventilated with a tidal volume of 6 to 7 mL/kg. Lung deflation was achieved by opening the endotracheal tube to the atmosphere. The SCV-pleura distances and the SCV CSAs were measured using ultrasound at the end of inflation and 0, 30, 60, 90, and 120 seconds after lung deflation. A P value deflation. Neither the SCV-pleura distance nor the CSA showed any further increase with time. Lung deflation failed to increase the SCV-pleura distance and the CSA of the SCV. Its application is unlikely to be advantageous in avoiding pneumothorax or improving the success rate of subclavian venous cannulation.

  11. Aggressive treatment of idiopathic axillo-subclavian vein thrombosis provides excellent long-term function.

    Science.gov (United States)

    Stone, David H; Scali, Salvatore T; Bjerk, Aja A; Rzucidlo, Eva; Chang, Catherine K; Goodney, Philip P; Nolan, Brian W; Walsh, Daniel B

    2010-07-01

    While much attention has been devoted toward treatment paradigms for idiopathic axillo-subclavian vein thrombosis (ASVT), little has focused on long-term durability of aggressive treatment and its associated functional outcomes. The purpose of this study was to review our own surgical therapeutic algorithm and its associated durability and functional outcomes. All patients treated with combined endovascular and open surgery at Dartmouth-Hitchcock Medical Center for ASVT from 1988 to 2008 were identified. Patient demographics, comorbidities, and operative techniques were recorded. Patency, freedom from reintervention, and functional outcomes were documented. Follow-up via telephone and clinic visit allowed quantitative comparison of functional status, pre- and postoperatively. Thirty-six patients were treated for ASVT throughout the study interval. Seven patients (19.4%) were lost to follow-up. Most patients were male (66%; N = 24); mean age was 32 years. Catheter-directed thrombolysis was utilized in the majority of patients (83.3%; N = 30) with an average time from symptom onset to lysis of 12 days. Surgical decompression was undertaken in all patients via transaxillary (52%; N = 19), supraclavicular (31%; N = 11), or infraclavicular approaches (17%; N = 6). Eleven stents were placed in 11 patients (30.5%) for residual stenotic disease. Mean follow-up was 65 months, with 1- and 5-year overall patency at 100% and 94%, respectively. Freedom from reintervention was 100% and 74.4% at 1 and 5 years, respectively. Seven patients (19.4%) required postoperative reintervention with four receiving additional lytic therapy, two requiring a stent, and one venoplasty. At presentation, 65.5% (N = 19) of patients were unable to work or perform routine activities. After treatment, 86% (N = 25) returned to their employment and have experienced sustained symptomatic and functional improvement. Patients with symptomatic idiopathic axillo-subclavian vein thrombosis can expect durable

  12. Nonbronchial systemic arteries: incidence and endovascular interventional management for hemoptysis

    International Nuclear Information System (INIS)

    Jiang Sen; Zhu Xiaohua; Sun Xiwen; You Zhengqian; Ma Jun; Yu Dong; Peng Gang; Jie Bing; Sun Chunyi

    2009-01-01

    Objective: To investigate the incidence and relation to primary diseases of the nonbronchial systemic arteries (NBSA) supply to the pulmonary lesions, and to evaluate the clinical value of transcatheter arterial embolization (TAE) of the responsibly NBSA for hemoptysis. Methods: The aortography and subclavian artery angiography were performed in 139 patients with hemoptysis, including pulmonary tuberculosis in 66 cases (2 cases with post-thoracoplasty, 1 case with post-lobectomy, and 1 case with ventricular septal defect), bronchiectasis in 41 (1 case with post-lobectomy and 1 case with post-ligation of patent ductus arteriosus), bronchiogenic carcinoma in 15, unknown hemoptysis in 7, silicosis in 3, broncholithiasis in 3, bronchial cysts in 1, empyema in 1, postoperative lung cancer in 1, and chronic pulmonary embolism in 1, respectively. TAE was performed in patients with the discoverable responsible NBSA. The frequency, distribution and relation to primary diseases of the responsible NBSA were evaluated and the clinical results and complications were observed. Follow-up time ranged from 6 months to 5 years. Results: Seventy-three patients (52.5%) had nonbronchial systemic contributions, including 5 cases of post-thoracotomy with pulmonary lesions, 1 case complicating with ventricular septal defect, 1 case with post-ligation of patent ductus arteriosus, and 1 case of chronic pulmonary embolism. The total number of NBSA were 181 including posterior intercostal arteries (n=88), internal thoracic arteries (n=27), inferior phrenic arteries (n=21), proper esophageal arteries (n=20), lateral thoracic arteries (n=9), subscapular arteries (n=7), costocervical trunks (n=5) and thyrocervical trunks (n=4). Main responsible NBSA were posterior intercostal arteries (n=75) and branches of subclavian and axillary artery (n=44) in patients with pulmonary tuberculosis, and proper esophageal arteries (n=16) and inferior phrenic arteries (n=17) in bronchiectasis. The clinical

  13. Low-energy foil aberration corrector

    International Nuclear Information System (INIS)

    Aken, R.H. van; Hagen, C.W.; Barth, J.E.; Kruit, P.

    2002-01-01

    A spherical and chromatic aberration corrector for electron microscopes is proposed, consisting of a thin foil sandwiched between two apertures. The electrons are retarded at the foil to almost zero energy, so that they can travel ballistically through the foil. It is shown that such a low-voltage corrector has a negative spherical aberration for not too large distances between aperture and foil, as well as a negative chromatic aberration. For various distances the third- and fifth-order spherical aberration coefficients and the first- and second-order chromatic aberration coefficients are calculated using ray tracing. Provided that the foils have sufficient electron transmission the corrector is able to correct the third-order spherical aberration and the first-order chromatic aberration of a typical low-voltage scanning electron microscope. Preliminary results show that the fifth-order spherical aberration and the second-order chromatic aberration can be kept sufficiently low

  14. Empirical description of bronchial and nonbronchial arteries with MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Li Huimin, E-mail: yuhongphd@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Dong Weihua, E-mail: dongweihua2000@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China)

    2010-08-15

    Purpose: We aimed to retrospectively evaluate bronchial and nonbronchial systemic arteries using multi-detector row helical computed tomographic (MDCT) angiography in patients with pulmonary disorders. Materials and Methods: Thirty-nine patients (24 men, 15 women; mean age, 63.4 years; range, 20-82 years) with congenital and acquired pulmonary disorders of the bronchial and nonbronchial systemic arteries underwent multi-detector row helical computed tomographic angiography of the thorax using a 16-detector row scanner. Each of these patients had experienced an episode of hemoptysis. Computed tomographic angiogram data, which included maximum intensity projections, multiplanar reconstruction, and three-dimensional volume-rendered images, were used to retrospectively analyse the characteristics of the bronchial and nonbronchial systemic arteries. Results: We identified a total of 128 bronchial arteries (76 on the right side and 52 on the left) in 39 patients. We detected 42 nonbronchial systemic artery branches, including 19 internal mammary artery branches, 8 subclavian artery branches, 8 inferior phrenic artery branches, 5 intercostal artery branches, 1 thyrocervical trunk branch, and 1 celiac trunk branch. Thirty-five dilated and tortuous nonbronchial systemic arteries entered into the lung parenchyma and extended down to the lesions. Every case, except the one case of sequestration, was associated with pleural thickening where the vascular structures passed through the extrapleural fat. Conclusions: The variations in both the bronchial artery anatomy and the location and type of the nonbronchial arteries were great. Nonbronchial arteries may be a significant source of hemoptysis. MDCT angiography can be used to detect detailed anatomical information about the origins and courses of bronchial and nonbronchial systemic arteries and their pathophysiologic features.

  15. Aberrant cervical vasculature anastomosis as cause of neck pain and successful treatment with embolization technique.

    Science.gov (United States)

    He, Lucy; Ladner, Travis R; Cobb, Mark; Mocco, J

    2016-01-27

    We report a patient with non-dermatomal radiating neck pain without focal neurologic deficit. Traditional workup could not identify an anatomic or biomechanical cause. Imaging showed a deep cervical vessel centered in the region of pain. Angiography later identified an aberrant anastomosis of this vessel with the occipital artery. Subsequent endovascular embolization of this arterial trunk resulted in complete pain relief. 2016 BMJ Publishing Group Ltd.

  16. Determination of aberration center of Ronchigram for automated aberration correctors in scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sannomiya, Takumi, E-mail: sannomiya@mtl.titech.ac.jp [Tokyo Institute of Technology, Ookayama, Tokyo (Japan); Sawada, Hidetaka; Nakamichi, Tomohiro; Hosokawa, Fumio [JEOL Limited, Akishima, Tokyo (Japan); Nakamura, Yoshio; Tanishiro, Yasumasa; Takayanagi, Kunio [Tokyo Institute of Technology, Ookayama, Tokyo (Japan)

    2013-12-15

    A generic method to determine the aberration center is established, which can be utilized for aberration calculation and axis alignment for aberration corrected electron microscopes. In this method, decentering induced secondary aberrations from inherent primary aberrations are minimized to find the appropriate axis center. The fitness function to find the optimal decentering vector for the axis was defined as a sum of decentering induced secondary aberrations with properly distributed weight values according to the aberration order. Since the appropriate decentering vector is determined from the aberration values calculated at an arbitrary center axis, only one aberration measurement is in principle required to find the center, resulting in /very fast center search. This approach was tested for the Ronchigram based aberration calculation method for aberration corrected scanning transmission electron microscopy. Both in simulation and in experiments, the center search was confirmed to work well although the convergence to find the best axis becomes slower with larger primary aberrations. Such aberration center determination is expected to fully automatize the aberration correction procedures, which used to require pre-alignment of experienced users. This approach is also applicable to automated aperture positioning. - Highlights: • A generic method to determine the aberration center is established for (S)TEM. • Decentering induced secondary aberrations are utilized to find the center. • The method is tested on Ronchigrams both in simulation and experiment. • Proper weighting of the aberration gives a good convergence. • Larger primary aberration results in a slower convergence.

  17. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  18. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  19. The Art of Optical Aberrations

    Science.gov (United States)

    Wylde, Clarissa Eileen Kenney

    Art and optics are inseparable. Though seemingly opposite disciplines, the combination of art and optics has significantly impacted both culture and science as they are now known. As history has run its course, in the sciences, arts, and their fruitful combinations, optical aberrations have proved to be a problematic hindrance to progress. In an effort to eradicate aberrations the simple beauty of these aberrational forms has been labeled as undesirable and discarded. Here, rather than approach aberrations as erroneous, these beautiful forms are elevated to be the photographic subject in a new body of work, On the Bright Side. Though many recording methods could be utilized, this work was composed on classic, medium-format, photographic film using white-light, Michelson interferometry. The resulting images are both a representation of the true light rays that interacted on the distorted mirror surfaces (data) and the artist's compositional eye for what parts of the interferogram are chosen and displayed. A detailed description of the captivating interdisciplinary procedure is documented and presented alongside the final artwork, CCD digital reference images, and deformable mirror contour maps. This alluring marriage between the arts and sciences opens up a heretofore minimally explored aspect of the inextricable art-optics connection. It additionally provides a fascinating new conversation on the importance of light and optics in photographic composition.

  20. Development of extrahepatic arterial blood supply to the liver during hepatic arterial infusion chemotherapy

    International Nuclear Information System (INIS)

    Seki, H.; Kimura, M.; Yoshimura, N.; Yamamoto, S.; Ozaki, T.; Sakai, K.

    1998-01-01

    The aim of this study was to evaluate the correlation of development of the collateral circulation to the liver during hepatic arterial infusion chemotherapy (HAIC) with the presence of hepatic tumours adjacent to the hepatic surface, and with pretreatment occlusion of aberrant hepatic arteries. In 102 patients with unresectable malignant hepatic tumours treated with HAIC using an implantable port system, development of collaterals to the liver was assessed with CT arteriography using the implantable port and pre- and postoperative angiography. Aberrant hepatic arteries, if present, were occluded prior to treatment for hepatic arterial redistribution. Collaterals to the liver were seen in 29 patients, who had 35 areas with collateral perfusion: 22 areas were in the right posterosuperior area, 6 in the left peripheral area and 7 in the right or left lobar area. Collaterals were revealed more frequently in patients with hepatic tumours adjacent to the hepatic surface than in those without hepatic tumours in peripheral areas in the liver (p < 0.0001). In addition, collaterals developed more frequently in patients with an aberrant hepatic arterial anatomy compared with those with conventional anatomy (p = 0.0007). Our results indicated that patients with hepatic tumours adjacent to the hepatic surface and with pretreatment occlusion of aberrant hepatic arteries had the potential to develop collaterals to the liver during HAIC. (orig.)

  1. Freeform aberrations in phase space: an example.

    Science.gov (United States)

    Babington, James

    2017-06-01

    We consider how optical propagation and aberrations of freeform systems can be formulated in phase space. As an example system, a freeform prism is analyzed and discussed. Symmetry considerations and their group theory descriptions are given some importance. Numerical aberrations are also highlighted and put into the context of the underlying aberration theory.

  2. Pathophysiology of MDS: genomic aberrations.

    Science.gov (United States)

    Ichikawa, Motoshi

    2016-01-01

    Myelodysplastic syndromes (MDS) are characterized by clonal proliferation of hematopoietic stem/progenitor cells and their apoptosis, and show a propensity to progress to acute myelogenous leukemia (AML). Although MDS are recognized as neoplastic diseases caused by genomic aberrations of hematopoietic cells, the details of the genetic abnormalities underlying disease development have not as yet been fully elucidated due to difficulties in analyzing chromosomal abnormalities. Recent advances in comprehensive analyses of disease genomes including whole-genome sequencing technologies have revealed the genomic abnormalities in MDS. Surprisingly, gene mutations were found in approximately 80-90% of cases with MDS, and the novel mutations discovered with these technologies included previously unknown, MDS-specific, mutations such as those of the genes in the RNA-splicing machinery. It is anticipated that these recent studies will shed new light on the pathophysiology of MDS due to genomic aberrations.

  3. Complications of Central Venous Totally Implantable Access Port: Internal Jugular Versus Subclavian Access

    Directory of Open Access Journals (Sweden)

    Pil Young Jung

    Full Text Available Background: Totally implantable access port (TIAP provides reliable, long term vascular access with minimal risk of infection and allows patients normal physical activity. With wide use of ports, new complications have been encountered. We analyzed TIAP related complications and evaluated the outcomes of two different percutaneous routes of access to superior vena cava. Methods: All 172 patients who underwent port insertion with internal jugular approach (Group 1, n = 92 and subclavian approach (Group 2, n = 79 between August 2011 and May 2013 in a single center were analyzed, retrospectively. Medical records were analyzed to compare the outcomes and the occurrence of port related complications between two different percutaneous routes of access to superior vena cava. Results: Median follow-up for TIAP was 278 days (range, 1-1868. Twenty four complications were occurred (14.0%, including pneumothorax (n = 1, 0.6%, migration/malposition (n = 4, 2.3%, pinch-off syndrome (n = 4, 2.3%, malfunction (n = 2, 1.1%, infection (n = 8, 4.7%, and venous thrombosis (n = 5, 2.9%. The overall incidence was 8.7% and 20.3% in each group (p = 0.030. Mechanical complications except infectious and thrombotic complications were more often occurred in group 2 (p = 0.033. The mechanical complication free probability is significantly higher in group 1 (p = 0.040. Conclusions: We suggest that the jugular access should be chosen in patients who need long term catheterization because of high incidence of mechanical complication, such as pinch-off syndrome.

  4. Spontaneous bilateral subclavian vein thrombosis in a 40-year-old man: A case report.

    Science.gov (United States)

    Huang, Chun-Yen; Wu, Yen-Hung; Yeh, I-Jeng; Chen, Yun-Yi; Kung, Fung-Ya

    2018-04-01

    Paget-Schroetter syndrome (PSS) is an uncommon condition that refers to primary (spontaneous) thrombosis of the deep veins that drain the upper extremities because of anatomical anomalies or repetitive strenuous arm activity. Bilateral spontaneous upper extremity deep-vein thrombosis (UEDVT) is an extremely rare phenomenon in adults, which may be misdiagnosed by physicians in acute settings. A 40-year-old man presented to our emergency department because of progressive left upper arm swelling for 1 day. He denied fever, chest pain, dyspnea, trauma, or any other systemic disease before. The swollen left arm also had no local heat or redness with normal radius pulsation. He was a laborer who lifted heavy objects. Blood examination included tests for complete blood count, renal function, liver function, blood coagulation profile, cardiac enzyme levels, and D-dimer level. Results showed that the white blood cell count, renal and liver functions, and cardiac enzyme levels were all within their normal ranges, except for the elevated D-dimer level (1.93 mg/L). Chest radiography and electrocardiography were performed with nonspecific findings. Subsequently, computed tomographic angiography was recommended for the suspected deep-vein thrombosis. The report showed venous thrombosis involving the bilateral subclavian and internal jugular veins. Heparin and enoxaparin were prescribed for this patient, with loading and maintenance doses. He was then admitted to our cardiovascular ward for further treatment. The patient was discharged 9 days later in a stable condition. Emergency physicians should consider the rare condition of UEDVT when a healthy patient presents with acute arm swelling. Patient history taking should be thorough, especially concerning the risk factors of secondary causes and possible frequent vigorous heavy lifting and overhead motion. Without secondary risk factors, primary upper deep-vein thrombosis might be suspected. Further laboratory tests and imaging

  5. Mask-induced aberration in EUV lithography

    Science.gov (United States)

    Nakajima, Yumi; Sato, Takashi; Inanami, Ryoichi; Nakasugi, Tetsuro; Higashiki, Tatsuhiko

    2009-04-01

    We estimated aberrations using Zernike sensitivity analysis. We found the difference of the tolerated aberration with line direction for illumination. The tolerated aberration of perpendicular line for illumination is much smaller than that of parallel line. We consider this difference to be attributable to the mask 3D effect. We call it mask-induced aberration. In the case of the perpendicular line for illumination, there was a difference in CD between right line and left line without aberration. In this report, we discuss the possibility of pattern formation in NA 0.25 generation EUV lithography tool. In perpendicular pattern for EUV light, the dominant part of aberration is mask-induced aberration. In EUV lithography, pattern correction based on the mask topography effect will be more important.

  6. Applied anatomy of thyroid arteries for interventional embolization of Graves' disease

    International Nuclear Information System (INIS)

    Ding Zhongxiang; Zhao Wei; Hou Jialin; Xiang Shutian; Li Liyuan; Zou Zhirong; Li Xingguo; Song Dianping; Yuan Jianhua

    2007-01-01

    Objective: To explore the anatomy and imaging manifestations of thyroid arteries for improving the efficiency and lowering the complication in interventional embolization of Graves' disease. Methods: Thyroid arteries were investigated, including 16 adult cadavers (Cadaver group), 8 non-thyropathic patients (Normal group)and 17 Graves patients (Graves group). The inner diameters of the trunk and supplying branches of thyroid artery, the angles between the origination of branches and the beginning of the trunk, and the angles between the trunk of thyroid artery and carotid or subclavian artery were measured. In addition, data of the three groups were statistically analyzed. Results: Many non-thyroid arterial branches arose from thyroid artery, with no statistical difference in their indexes between Cadaver group and Normal group. The thyroid arteries showed much longer, obviously wider in diameter, and larger angles between the trunk of thyroid artery and carotid artery in Graves group than those of Cadaver group and Normal group; outcoming with significant statistical differences; and furthermore, with increase of interglandular branches and dangerous internal and external anastomoses. Conclusions: The specific thyroid arterial changes of Graves' disease are helpful for the interventional embolization. Non-thyroid branches and dangerous anastomoses should not be embolized as far as possible, for decreasing the complications of the interventional procedure for Graves' disease. (authors)

  7. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  8. Correlations between corneal and total wavefront aberrations

    Science.gov (United States)

    Mrochen, Michael; Jankov, Mirko; Bueeler, Michael; Seiler, Theo

    2002-06-01

    Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p the corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p equals 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.

  9. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    Tokue, Hiroyuki; Tokue, Azusa; Tsushima, Yoshito

    2012-01-01

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  10. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    Directory of Open Access Journals (Sweden)

    Tokue Hiroyuki

    2012-12-01

    Full Text Available Abstract Background We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP using routine 64 multidetector-row computed tomography (MDCT data in order to plan for the implantation of an intra-arterial hepatic port system. Methods A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward. Results The median branching angle was (median ± standard deviation 135 ± 23 (range, 51–174 degrees. The branching was upward in 77 patients (7% and downward in 1,027 patients (93%. The branching was downward with an angle of 120 to150 degrees in most patients (n = 613. The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%. A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. Conclusions The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery.

  11. Immediate Bilateral Breast Reconstruction with Unilateral Deep Superior Epigastric Artery and Superficial Circumflex Iliac Artery Flaps

    Directory of Open Access Journals (Sweden)

    Keith S. Hansen

    2016-09-01

    Full Text Available Autologous breast reconstruction utilizing a perforator flap is an increasingly popular method for reducing donor site morbidity and implant-related complications. However, aberrant anatomy not readily visible on computed tomography angiography is a rare albeit real risk when undergoing perforator flap reconstruction. We present an operative case of a patient who successfully underwent a bilateral breast reconstruction sourced from a unilateral abdominal flap divided into deep superior epigastric artery and superficial circumflex iliac artery flap segments.

  12. Chromosomal aberrations in ore miners of Slovakia

    International Nuclear Information System (INIS)

    Beno, M.; Vladar, M.; Nikodemova, D.; Vicanova, M.; Durcik, M.

    1998-01-01

    A pilot study was performed in which the incidence of chromosomal aberrations in lymphocytes of miners in ore mines located in Central Slovakia was monitored and related to lifetime underground radon exposure and to lifetime smoking. The conclusions drawn from the results of the study were as follows: the counts of chromosomal aberrations in lymphocytes of miners were significantly higher than in an age matched control group of white-collar staff; the higher counts of chromosomal aberrations could be ascribed to underground exposure of miners and to smoking; a dependence of chromosomal aberration counts on the exposure to radon could not be assessed. (A.K.)

  13. Operative and endovascular management of extracranial vertebral artery aneurysm in Ehlers-Danlos syndrome:a clinical dilemma--case report and literature review.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2002-01-01

    The most prevalent lesion of the vertebral artery is an atheromatous plaque located at its origin from the subclavian artery. A case of successful management of a symptomatic vertebral artery aneurysm due to Ehlers-Danlos syndrome is reported. The patient had asymptomatic posterior intracerebral artery dissection on the contralateral side. A common carotid artery to V-3 segment bypass using reversed saphenous vein graft was carried out. Avulsion of the V-2 segment occurred peroperatively and endovascular coil embolization of the vertebral artery aneurysm was performed. Endovascular equipment and training must be in the armamentarium of vascular surgeons as more complex cases are being treated, which demands new approaches for ultimate clinical success. This unique case outlines what might unexpectedly occur. Endovascular intervention as an adjuvant procedure provides a satisfactory outcome in what could have been a catastrophe.

  14. Possible mechanisms of chromosome aberrations. 2. Formation of aberrations after UV-irradiation

    International Nuclear Information System (INIS)

    Lebedeva, L.I.

    1982-01-01

    One of mechanisms of chromosome aberrations after UV-radiation of animal cells initiated by thymine dimerization from different dna threads (by cross joints) and finished in mitosis metaphase is discussed. The model of aberration formation, taking a count of peculiarities of chromosome ansate structure and predicting the important role of chromosome isolation during mitosis in realization of structural aberrations, is suggested. An attempt to present aberration formation under conditions of exact repair is the distinguishing feature of the model

  15. Transbrachial artery approach for selective cerebral angiography

    International Nuclear Information System (INIS)

    Touho, Hajime; Karasawa, Jun; Shishido, Hisashi; Morisako, Toshitaka; Numazawa, Shinichi; Yamada, Keisuke; Nagai, Shigeki; Shibamoto, Kenji

    1990-01-01

    Transaxillary or transbrachial approaches to the cerebral vessels have been reported, but selective angiography of all four vessels has not been possible through one route. In this report, a new technique for selective cerebral angiography with transbrachial approach is described. One hundred and twenty three patients with cerebral infarction, vertebrobasilar insufficiency, intracerebral hemorrhage, epilepsy, or cerebral tumor were examined. Those patients consisted of 85 outpatients and 38 inpatients whose age ranged from 15 years old to 82 years old. The patients were examined via the transbrachial approach (97 cases via the right brachial, 29 cases via the left). Materials included a DSA system (Digital Fluorikon 5000, General Electric Co.), a 4 French tight J-curved Simmons 80-cm catheter, a 19-gauge extra-thin-wall Seldinger needle, and a J/Straight floppy 125-cm guide-wire. Generally, the volume of the contrast agent (300 mgI/ml iopamidol) used in the common carotid artery angiogram was 6 ml, while that used in the vertebral artery angiogram was 4 ml. If catheterization of the vertebral artery or right common carotid artery was unsuccessful, about 8 ml of the contrast agent was injected into the subclavian or branchiocephalic artery. Definitive diagnosis and a decision on proper treatment of the patients can be easily obtained, and the results were clinically satisfactory. Moreover, no complications were encountered in this study. This new technique making a transbrachial approach to the cerebral vessels using the DSA system is introduced here. Neurosurgeons can use this technique easily, and they will find that it provides them with all the information they need about the patient. (author)

  16. Rooting Out Aberrant Behavior in Training.

    Science.gov (United States)

    Kokalis, Jerry, Jr.; Paquin, Dave

    1989-01-01

    Discusses aberrant, or disruptive, behavior in an industrial/business, classroom-based, instructor-led training setting. Three examples of aberrant behavior are described, typical case studies are provided for each, and preventive (long-term) and corrective (on-the-spot) strategies for dealing with the problems are discussed. (LRW)

  17. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    International Nuclear Information System (INIS)

    Nicholson, Tony; Ettles, Duncan; Robinson, Graham

    2004-01-01

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred with carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device

  18. Nodal aberration theory applied to freeform surfaces

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P.; Thompson, Kevin P.

    2014-12-01

    When new three-dimensional packages are developed for imaging optical systems, the rotational symmetry of the optical system is often broken, changing its imaging behavior and making the optical performance worse. A method to restore the performance is to use freeform optical surfaces that compensate directly the aberrations introduced from tilting and decentering the optical surfaces. In order to effectively optimize the shape of a freeform surface to restore optical functionality, it is helpful to understand the aberration effect the surface may induce. Using nodal aberration theory the aberration fields induced by a freeform surface in an optical system are explored. These theoretical predications are experimentally validated with the design and implementation of an aberration generating telescope.

  19. Aberration characteristics of immersion lenses for LVSEM

    International Nuclear Information System (INIS)

    Khursheed, Anjam

    2002-01-01

    This paper investigates the on-axis aberration characteristics of various immersion objective lenses for low voltage scanning electron microscopy (LVSEM). A simple aperture lens model is used to generate smooth axial field distributions. The simulation results show that mixed field electric-magnetic immersion lenses are predicted to have between 1.5 and 2 times smaller aberration limited probe diameters than their pure-field counterparts. At a landing energy of 1 keV, mixed field immersion lenses operating at the vacuum electrical field breakdown limit are predicted to have on-axis aberration coefficients between 50 and 60 μm, yielding an ultimate image resolution of below 1 nm. These aberrations lie in the same range as those for LVSEM systems that employ aberration correctors

  20. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    International Nuclear Information System (INIS)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients with

  1. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki [Social Insurance Chukyo Hospital, Nagoya (Japan)

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients

  2. [Monochromatic aberration in accommodation. Dynamic wavefront analysis].

    Science.gov (United States)

    Fritzsch, M; Dawczynski, J; Jurkutat, S; Vollandt, R; Strobel, J

    2011-06-01

    Monochromatic aberrations may influence the visual acuity of the eye. They are not stable and can be affected by different factors. The subject of the following paper is the dynamic investigation of the changes in wavefront aberration with accommodation. Dynamic measurement of higher and lower order aberrations was performed with a WASCA Wavefront Analyzer (Carl-Zeiss-Meditec) and a specially constructed target device for aligning objects in far and near distances on 25 subjects aged from 15 to 27 years old. Wavefront aberrations showed some significant changes in accommodation. In addition to the characteristic sphere reaction accompanying miosis and changes in horizontal prism (Z(1) (1)) in the sense of a convergence movement of the eyeball also occurred. Furthermore defocus rose (Z(2) (0)) and astigmatism (Z(2) (-2)) changed. In higher-order aberrations a decrease in coma-like Zernike polynomials (Z(3) (-1), Z(3) (1)) was found. The most obvious change appeared in spherical aberration (Z(4) (0)) which increased and changed from positive to negative. In addition the secondary astigmatism (Z(4) (-2)) and quadrafoil (Z(4) (4)) rise also increased. The total root mean square (RMS), as well as the higher-order aberrations (RMS-HO) significantly increased in accommodation which is associated with a theoretical reduction of visual acuity. An analysis of the influence of pupil size on aberrations showed significant increases in defocus, spherical aberration, quadrafoil, RMS and RMS HO by increasing pupil diameter. By accommodation-associated miosis, the growing aberrations are partially compensated by focusing on near objects. Temporal analysis of the accommodation process with dynamic wavefront analysis revealed significant delays in pupil response and changing of prism in relation to the sphere reaction. In accommodation to near objects a discrete time ahead of third order aberrations in relation to the sphere response was found. Using dynamic wavefront measurement

  3. Flow cytogenetics: progress toward chromosomal aberration detection

    International Nuclear Information System (INIS)

    Carrano, A.V.; Gray, J.W.; Van Dilla, M.A.

    1977-01-01

    Using clonal derivatives of the Chinese hamster M3-1 cell line, we demonstrate the potential of flow systems to karyotype homogeneous aberrations (aberrations which are identical and present in every cell) and to detect heterogeneous aberrations (aberrations which occur randomly in a population and are not identical in every cell). Flow cytometry (FCM) of ethidium bromide stained isolated chromosomes from clone 650A of the M3-1 cells distinguishes nine chromosome types from the fourteen present in the actual karyotype. X-irradiation of this parent 650A clone produced two sub-clones with an altered flow karyotype, that is, their FCM distributions were characterized by the addition of new peaks and alterations in area under existing peaks. From the relative DNA content and area for each peak, as determined by computer analysis, we predicted that each clone had undergone a reciprocal translocation involving chromosomes from two peaks. This prediction was confirmed by Giemsa-banding the metaphase cells. Heterogeneous aberrations are reflected in the flow karyotype as an increase in background, that is, an increase in area underlying the chromosome peaks. This increase is dose dependent but, as yet, the sample variability has been too large for quantitative analysis. Flow sorting of the valleys between chromosome peaks produces enriched fractions of aberrant chromosomes for visual analysis. These approaches are potentially applicable to the analysis of chromsomal aberrations induced by environmental contaminants

  4. Iteration of ultrasound aberration correction methods

    Science.gov (United States)

    Maasoey, Svein-Erik; Angelsen, Bjoern; Varslot, Trond

    2004-05-01

    Aberration in ultrasound medical imaging is usually modeled by time-delay and amplitude variations concentrated on the transmitting/receiving array. This filter process is here denoted a TDA filter. The TDA filter is an approximation to the physical aberration process, which occurs over an extended part of the human body wall. Estimation of the TDA filter, and performing correction on transmit and receive, has proven difficult. It has yet to be shown that this method works adequately for severe aberration. Estimation of the TDA filter can be iterated by retransmitting a corrected signal and re-estimate until a convergence criterion is fulfilled (adaptive imaging). Two methods for estimating time-delay and amplitude variations in receive signals from random scatterers have been developed. One method correlates each element signal with a reference signal. The other method use eigenvalue decomposition of the receive cross-spectrum matrix, based upon a receive energy-maximizing criterion. Simulations of iterating aberration correction with a TDA filter have been investigated to study its convergence properties. A weak and strong human-body wall model generated aberration. Both emulated the human abdominal wall. Results after iteration improve aberration correction substantially, and both estimation methods converge, even for the case of strong aberration.

  5. Diagnostic radiation and chromosome aberrations

    International Nuclear Information System (INIS)

    Patil, S.R.; Hecht, F.; Lubs, H.A.; Kimberling, W.; Brown, J.; Gerald, P.S.; Summitt, R.L.

    1977-01-01

    Some evidence is presented suggesting that diagnostic X-rays may be important in the origin of a new chromosomal abnormality other than Down syndrome. Chromosome analyses have been carried out on 4342 children, seven or eight years old. Maternal diagnostic irradiation in the year before conception and up to third lunar month of the index pregnancy was recorded, before the chromosome study began, together with a large amount of family and clinical data. Information on X-ray exposure was supplied by the mothers, s o radiation dosage could not be estimated. 21 children (including a pair of twins and a pair of siblings) born to 19 mothers had chromosomal aberrations. The mothers of six children with inherited translocations, rearrangements and XYY karyotypes were excluded, and 3 (23%) of the remaining 13 mothers had received abdominal and pelvic X-ray exposures. In the whole sample, however, only 6% of the mothers had diagnostic irradiation. Two of these mothers, aged sixteen and twenty, gave birth to a child each with de-novo autosomal translocations, and the third mother, aged thirty-two, had a child with a complex mosaicism involving one X chromosome. Although the sample size of the mothers with chromosomally abnormal children is small, the results are significant. (U.K.)

  6. Diagnostic radiation and chromosome aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Patil, S R; Hecht, F [Dept. of Pediatrics, Child Development and Rehabilitation Center, Univ. of Oregon Health Sciences Center, Portland, Oregon (USA); Lubs, H A; Kimberling, W; Brown, J; Gerald, P S; Summitt, R L

    1977-01-15

    Some evidence is presented suggesting that diagnostic X-rays may be important in the origin of a new chromosomal abnormality other than Down syndrome. Chromosome analyses have been carried out on 4342 children, seven or eight years old. Maternal diagnostic irradiation in the year before conception and up to third lunar month of the index pregnancy was recorded, before the chromosome study began, together with a large amount of family and clinical data. Information on X-ray exposure was supplied by the mothers, so radiation dosage could not be estimated. 21 children (including a pair of twins and a pair of siblings) born to 19 mothers had chromosomal aberrations. The mothers of six children with inherited translocations, rearrangements and XYY karyotypes were excluded, and 3 (23%) of the remaining 13 mothers had received abdominal and pelvic X-ray exposures. In the whole sample, however, only 6% of the mothers had diagnostic irradiation. Two of these mothers, aged sixteen and twenty, gave birth to a child each with de-novo autosomal translocations, and the third mother, aged thirty-two, had a child with a complex mosaicism involving one X chromosome. Although the sample size of the mothers with chromosomally abnormal children is small, the results are significant.

  7. Chromosome aberration assays in Allium

    Energy Technology Data Exchange (ETDEWEB)

    Grant, W.F.

    1982-01-01

    The common onion (Allium cepa) is an excellent plant for the assay of chromosome aberrations after chemical treatment. Other species of Allium (A. cepa var. proliferum, A. carinatum, A. fistulosum and A. sativum) have also been used but to a much lesser extent. Protocols have been given for using root tips from either bulbs or seeds of Allium cepa to study the cytological end-points, such as chromosome breaks and exchanges, which follow the testing of chemicals in somatic cells. It is considered that both mitotic and meiotic end-points should be used to a greater extent in assaying the cytogenetic effects of a chemical. From a literature survey, 148 chemicals are tabulated that have been assayed in 164 Allium tests for their clastogenic effect. Of the 164 assays which have been carried out, 75 are reported as giving a positive reaction, 49 positive and with a dose response, 1 positive and temperature-related, 9 borderline positive, and 30 negative; 76% of the chemicals gave a definite positive response. It is proposed that the Allium test be included among those tests routinely used for assessing chromosomal damage induced by chemicals.

  8. Aberrant regeneration of the third cranial nerve.

    Science.gov (United States)

    Shrestha, U D; Adhikari, S

    2012-01-01

    Aberrant regeneration of the third cranial nerve is most commonly due to its damage by trauma. A ten-month old child presented with the history of a fall from a four-storey building. She developed traumatic third nerve palsy and eventually the clinical features of aberrant regeneration of the third cranial nerve. The adduction of the eye improved over time. She was advised for patching for the strabismic amblyopia as well. Traumatic third nerve palsy may result in aberrant regeneration of the third cranial nerve. In younger patients, motility of the eye in different gazes may improve over time. © NEPjOPH.

  9. Transverse correlation vanishing due to phase aberrations

    CSIR Research Space (South Africa)

    Godin, T

    2011-06-01

    Full Text Available of the effects of each aberration on the ratio Sp ?? / , the following condition are imposed: 0max3max2max1 )()()( ??????? === . (9) It is assumed that the phase aberration is set in the beam-waist plane of radius mmW 5.10 = . Arbitrarily, the value... of max? is fixed to twice the incident beam width, 0max 2W=? , where the intensity is only 0.03% of the on-axis value. In the following we will express the aberration 0? in number of equivalent wavelengths given by the ratio )2/(00 pi...

  10. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  11. Severe tracheobronchial compression in a patient with Turner′s syndrome undergoing repair of a complex aorto-subclavian aneurysm: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Christopher C .C. Hudson

    2014-01-01

    Full Text Available We present a case of severe tracheobronchial compression from a complex aorto-subclavian aneurysm in a patient with Turner′s syndrome undergoing open surgical repair. Significant airway compression is a challenging situation and requires careful preoperative preparation, maintenance of spontaneous breathing when possible, and consideration of having an alternative source of oxygenation and circulation established prior to induction of general anesthesia. Cardiopulmonary monitoring is essential for safe general anesthesia and diagnosis of unexpected intraoperative events.

  12. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    Science.gov (United States)

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  13. Pulse compressor with aberration correction

    Energy Technology Data Exchange (ETDEWEB)

    Mankos, Marian [Electron Optica, Inc., Palo Alto, CA (United States)

    2015-11-30

    In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded

  14. Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery

    Science.gov (United States)

    Teragawa, Hiroki; Sueda, Takashi; Fujii, Yuichi; Takemoto, Hiroaki; Toyota, Yasushi; Nomura, Shuichi; Nakagawa, Keigo

    2013-01-01

    We report a successful endovascular technique using a snare with a suture for retrieving a migrated broken peripherally inserted central catheter (PICC) in a chemotherapy patient. A 62-year-old male received monthly chemotherapy through a central venous port implanted into his right subclavian area. The patient completed chemotherapy without complications 1 mo ago; however, he experienced pain in the right subclavian area during his last chemotherapy session. Computed tomography on that day showed migration of a broken PICC in his left pulmonary artery, for which the patient was admitted to our hospital. We attempted to retrieve the ectopic PICC through the right jugular vein using a gooseneck snare, but were unsuccessful because the catheter was lodged in the pulmonary artery wall. Therefore, a second attempt was made through the right femoral vein using a snare with triple loops, but we could not grasp the migrated PICC. Finally, a string was tied to the top of the snare, allowing us to curve the snare toward the pulmonary artery by pulling the string. Finally, the catheter body was grasped and retrieved. The endovascular suture technique is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters. PMID:24109502

  15. Geometric characteristics of aberrations of plane-symmetric optical systems

    International Nuclear Information System (INIS)

    Lu Lijun; Deng Zhiyong

    2009-01-01

    The geometric characteristics of aberrations of plane-symmetric optical systems are studied in detail with a wave-aberration theory. It is dealt with as an extension of the Seidel aberrations to realize a consistent aberration theory from axially symmetric to plane-symmetric systems. The aberration distribution is analyzed with the spot diagram of a ray and an aberration curve. Moreover, the root-mean-square value and the centroid of aberration distribution are discussed. The numerical results are obtained with the focusing optics of a toroidal mirror at grazing incidence.

  16. Neonatal intestinal volvulus due to a persistent right vitelline artery.

    Science.gov (United States)

    Loh, Amos H P; Prasad, Sai T R; Chew, Sung-Hock; Jacobsen, Anette S

    2007-04-01

    We report a case of neonatal intestinal volvulus around a persistent right vitelline artery, presenting as an aberrant parieto-mesenteric band on exploratory laparotomy. To our knowledge, this is the first case report in the English literature of a persistent right vitelline artery causing axial intestinal volvulus in a neonate. A review of the literature and the embryopathogenesis is discussed, as well as the importance of emergent diagnoses of such lesions.

  17. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  18. Spherical aberrations of human astigmatic corneas.

    Science.gov (United States)

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  19. Frequencies of chromosome aberration on radiation workers

    International Nuclear Information System (INIS)

    Yanti Lusiyanti; Zubaidah Alatas

    2016-01-01

    Radiation exposure of the body can cause damage to the genetic material in cells (cytogenetic) in the form of changes in the structure or chromosomal aberrations in peripheral blood lymphocytes. Chromosomal aberrations can be unstable as dicentric and ring chromosomes, and is stable as translocation. Dicentric chromosome is the gold standard biomarker due to radiation exposure, and chromosome translocation is a biomarker for retrospective biodosimetry. The aim of this studi is to conduct examination of chromosomal aberrations in the radiation worker to determine the potential damage of cell that may arise due to occupational radiation exposure. The examination have been carried out on blood samples from 55 radiation workers in the range of 5-30 year of service. Chromosome aberration frequency measurement starts with blood sampling, culturing, harvesting, slide preparations, and lymphocyte chromosome staining with Giemsa and painting with Fluorescence In Situ Hybridization (FISH) technique. The results showed that chromosomal translocations are not found in blood samples radiation workers and dicentric chromosomes found only on 2 blood samples of radiation workers with a frequency of 0.001/cell. The frequency of chromosomal aberrations in the blood cells such workers within normal limits and this means that the workers have been implemented a radiation safety aspects very well. (author)

  20. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-01-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery

  1. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-02-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery.

  2. Recurrent branchial sinus tract with aberrant extension.

    Science.gov (United States)

    Barret, J P

    2004-01-01

    Second branchial cysts are the commonest lesions among congenital lateral neck anomalies. Good knowledge of anatomy and embryology are necessary for proper treatment. Surgical treatment involves resection of all branchial remnants, which extend laterally in the neck, medial to the sternocleidomastoid muscle with cranial extension to the pharynx and ipsilateral tonsillar fosa. However, infections and previous surgery can distort anatomy, making the approach to branchial anomalies more difficult. We present a case of a 17-year-old patient who presented with a second branchial tract anomaly with an aberrant extension to the midline and part of the contralateral neck. Previous surgical interventions and chronic infections may have been the primary cause for this aberrant tract. All head and neck surgeons should bear in mind that aberrant presentations may exist when reoperating on chronic branchial cysts fistulas.

  3. An aberrant precision account of autism.

    Directory of Open Access Journals (Sweden)

    Rebecca P Lawson

    2014-05-01

    Full Text Available Autism is a neurodevelopmental disorder characterised by problems with social-communication, restricted interests and repetitive behaviour. A recent and controversial article presented a compelling normative explanation for the perceptual symptoms of autism in terms of a failure of Bayesian inference (Pellicano and Burr, 2012. In response, we suggested that when Bayesian interference is grounded in its neural instantiation – namely, predictive coding – many features of autistic perception can be attributed to aberrant precision (or beliefs about precision within the context of hierarchical message passing in the brain (Friston et al., 2013. Here, we unpack the aberrant precision account of autism. Specifically, we consider how empirical findings – that speak directly or indirectly to neurobiological mechanisms – are consistent with the aberrant encoding of precision in autism; in particular, an imbalance of the precision ascribed to sensory evidence relative to prior beliefs.

  4. Chromosomal aberrations induced by alpha particles

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M.

    2005-01-01

    The chromosomal aberrations produced by the ionizing radiation are commonly used when it is necessary to establish the exposure dose of an individual, it is a study that is used like complement of the traditional physical systems and its application is only in cases in that there is doubt about what indicates the conventional dosimetry. The biological dosimetry is based on the frequency of aberrations in the chromosomes of the lymphocytes of the individual in study and the dose is calculated taking like reference to the dose-response curves previously generated In vitro. A case of apparent over-exposure to alpha particles to which is practiced analysis of chromosomal aberrations to settle down if in fact there was exposure and as much as possible, to determine the presumed dose is presented. (Author)

  5. Electrostatic axisymmetric mirror with removable spherical aberration

    International Nuclear Information System (INIS)

    Birmuzaev, S.B.; Serikbaeva, G.S.; Hizirova, M.A.

    1999-01-01

    The electrostatic axisymmetric mirror, assembled from three coaxial cylinders with an equal diameter d and under the potential v1, v2 and v3, was computed. The proportions of geometrical and electric parameters of the mirror, with which the spherical 3-order aberration may be eliminated, were determined. The computation outcomes of the case, when the focal power of the mirror is enough large and the object plane in the focus is out of its field, are presented (Fig. 1 - potentials proportion that makes elimination of the spherical aberration possible; Fig. 2 - the focus coordinates when the spherical aberration is eliminated). The geometrical values are presented by d, and the electric ones are presented by v1. The figures on the curves present a length of the second (middle) electrode. The zero point is located in the middle of the gap between the first and second electrodes The investigated mirror may be used as a lens for the transmission electron microscope

  6. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  7. Estimation of dose from chromosome aberration rate

    International Nuclear Information System (INIS)

    Li Deping

    1990-01-01

    The methods and skills of evaluating dose from correctly scored shromsome aberration rate are presented, and supplemented with corresponding BASIC computer code. The possibility and preventive measures of excessive probability of missing score of the aberrations in some of the current routine score methods are discussed. The use of dose-effect relationship with exposure time correction factor G in evaluating doses and their confidence intervals, dose estimation in mixed n-γ exposure, and identification of high by nonuniform acute exposure to low LET radiation and its dose estimation are discussed in more detail. The difference of estimated dose due to whether the interaction between subleisoms produced by n and γ have been taken into account is examined. In fitting the standard dose-aberration rate curve, proper weighing of experiment points and comparison with commonly accepted values are emphasised, and the coefficient of variation σ y √y of the aberration rate y as a function of dose and exposure time is given. In appendix I and II, the dose-aberration rate formula is derived from dual action theory, and the time variation of subleisom is illustrated and in appendix III, the estimation of dose from scores of two different types of aberrations (of other related score) is illustrated. Two computer codes are given in appendix IV, one is a simple code, the other a complete code, including the fitting of standard curve. the skills of using compressed data storage, and the production of simulated 'data ' for testing the curve fitting procedure are also given

  8. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  9. Aberration Correction in the Brewer Spectrophotometer

    International Nuclear Information System (INIS)

    Johnston, J.E.; Kerr, J.B.; McElroy, C.T.; Wardle, D.I.

    2000-01-01

    The optical design of the Brewer Spectrophotometer has been optimised for measurements in the 300-320 nm wavelength range. An aberration resolution limit that is much less than the 0.6 nm FWHM (full width at half maximum) is achieved by using an Ebert-Fastie spectrometer design, modified by the inclusion tilted lens that optimises performance at 310 nm. The small contribution of the remaining aberration to the measured instrument function is critical to radiometric measurement quality. Ramifications of this design to the development of instrumentation with enhanced scanning abilities are discussed. (author)

  10. Implication of the presence of a variant hepatic artery during the Whipple procedure.

    Science.gov (United States)

    Rubio-Manzanares-Dorado, Mercedes; Marín-Gómez, Luis Miguel; Aparicio-Sánchez, Daniel; Suárez-Artacho, Gonzalo; Bellido, Carmen; Álamo, José María; Serrano-Díaz-Canedo, Juan; Padillo-Ruiz, Francisco Javier; Gómez-Bravo, Miguel Ángel

    2015-07-01

    The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD) in patients with or without a variant hepatic artery arising from superior mesenteric artery. We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean +/- standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%). The most frequent variant was an aberrant right hepatic artery (n = 7), following by the accessory right hepatic artery (n = 2) and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2). In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  11. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  12. Effect of aberrations in human eye on contrast sensitivity function

    Science.gov (United States)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.

  13. Spectral estimation for characterization of acoustic aberration.

    Science.gov (United States)

    Varslot, Trond; Angelsen, Bjørn; Waag, Robert C

    2004-07-01

    Spectral estimation based on acoustic backscatter from a motionless stochastic medium is described for characterization of aberration in ultrasonic imaging. The underlying assumptions for the estimation are: The correlation length of the medium is short compared to the length of the transmitted acoustic pulse, an isoplanatic region of sufficient size exists around the focal point, and the backscatter can be modeled as an ergodic stochastic process. The motivation for this work is ultrasonic imaging with aberration correction. Measurements were performed using a two-dimensional array system with 80 x 80 transducer elements and an element pitch of 0.6 mm. The f number for the measurements was 1.2 and the center frequency was 3.0 MHz with a 53% bandwidth. Relative phase of aberration was extracted from estimated cross spectra using a robust least-mean-square-error method based on an orthogonal expansion of the phase differences of neighboring wave forms as a function of frequency. Estimates of cross-spectrum phase from measurements of random scattering through a tissue-mimicking aberrator have confidence bands approximately +/- 5 degrees wide. Both phase and magnitude are in good agreement with a reference characterization obtained from a point scatterer.

  14. The correction of electron lens aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, P.W., E-mail: peter.hawkes@cemes.fr

    2015-09-15

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies.

  15. Quality factor of aberrated gaussian laser beams

    CSIR Research Space (South Africa)

    Mafusire, C

    2010-09-01

    Full Text Available 15 20 25 30 35 M 4 © CSIR 2010 www.csir.co.za Conclusion • Laser beam quality depends on - y-Astigmatism - y-Coma - x-Coma - y-Triangular astigmatism - x-Triangular astigmatism - Spherical aberration...

  16. The correction of electron lens aberrations

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    2015-01-01

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies

  17. Non-random intrachromosomal distribution of radiation-induced chromatid aberrations in Vicia faba. [Aberration clustering

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, I; Rieger, R [Akademie der Wissenschaften der DDR, Gatersleben. Zentralinst. fuer Genetik und Kulturpflanzenforschung

    1976-04-01

    A reconstructed karyotype of Vicia faba, with all chromosomes individually distinguishable, was treated with X-rays, fast neutrons, (/sup 3/H) uridine (/sup 3/HU). The distribution within metaphase chromosomes of induced chromatid aberrations was non-random for all agents used. Aberration clustering, in part agent specific, occurred in chromosome segments containing heterochromatin as defined by the presence of G bands. The pattern of aberration clustering found after treatment with /sup 3/HU did not allow the recognition of chromosome regions active in transcription during treatment. Furthermore, it was impossible to obtain unambiguous indications of the presence of AT- and GC-base clusters from the patterns of /sup 3/HT- and /sup 3/HC-induced chromatid aberrations, respectively. Possible reasons underlying these observations are discussed.

  18. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  19. Arterial embolism

    Science.gov (United States)

    ... when a clot in a vein enters the right side of the heart and passes through a hole into the left side. The clot can then move to an artery and block blood flow to the brain (stroke) or other organs. If a clot involves ...

  20. Ectopic origin of bronchial arteries: assessment with multidetector helical CT angiography

    International Nuclear Information System (INIS)

    Hartmann, Ieneke J.C.; Remy-Jardin, Martine; Menchini, Laura; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques

    2007-01-01

    The purpose of this study was to determine non-invasively the frequency of ectopic bronchial arteries (BA) (i.e., bronchial arteries originating at a level of the descending aorta other than T5-T6 or from any aortic collateral vessel) on multidetector-row CT angiograms (CTA) obtained in patients with hemoptysis. Over a 5-year period (2000-2005), 251 consecutive patients with hemoptysis underwent multidetector-row CT angiography of the thorax. From this population, 37 patients were excluded because of a suboptimal CTA examination (n = 19), the presence of extensive mediastinal disease (n = 15) or severe chest deformation (n = 3) precluding any precise analysis of the bronchial arteries at CTA. Our final study group included 214 patients who underwent a thin-collimated CT angiogram (contrast agent: 300 to 350 mg/ml) on a 4- (n = 56), 16- (n = 119) and 64- (n = 39) detector-row scanner. The site of origin and distribution of bronchial arteries were analyzed on transverse CT scans, maximum intensity projections and volume-rendered images. The site of the ostium of a bronchial artery was coded as orthotopic when the artery originated from the descending aorta between the levels of the fifth and sixth thoracic vertebrae; all other bronchial arteries were considered ectopic. From the studied population, 137 (64%) patients had only orthotopic bronchial arteries, whereas 77 patients (36%) had at least one bronchial artery of ectopic origin. A total of 147 ectopic arteries were depicted, originating as common bronchial trunks (n = 23; 19%) or isolated right or left bronchial arteries (n = 101; 81%). The most frequent sites of origin of the 124 ostiums were the concavity of the aortic arch (92/124; 74%), the subclavian artery (13/124; 10.5%) and the descending aorta (10/124; 8.5%). The isolated ectopic bronchial arteries supplied the ipsilateral lung in all but three cases. Bronchial artery embolization was indicated in 26 patients. On the basis of CTA information, (1

  1. Measuring and correcting aberrations of a cathode objective lens

    International Nuclear Information System (INIS)

    Tromp, R.M.

    2011-01-01

    In this paper I discuss several theoretical and practical aspects related to measuring and correcting the chromatic and spherical aberrations of a cathode objective lens as used in Low Energy Electron Microscopy (LEEM) and Photo Electron Emission Microscopy (PEEM) experiments. Special attention is paid to the various components of the cathode objective lens as they contribute to chromatic and spherical aberrations, and affect practical methods for aberration correction. This analysis has enabled us to correct a LEEM instrument for the spherical and chromatic aberrations of the objective lens. -- Research highlights: → Presents a comprehensive theory of the relation between chromatic aberration and lens current in a cathode objective lens. → Presents practical methods for measuring both spherical and chromatic aberrations of a cathode objective lens. → Presents measurements of these aberrations in good agreement with theory. → Presents practical methods for measuring and correcting these aberrations with an electron mirror.

  2. The prediction of spherical aberration with schematic eyes.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1996-07-01

    Many model eyes have been proposed; they differ in optical characteristics and therefore have different aberrations and image quality. In predicting the visual performance of the eye, we are most concerned with the central foveal vision. Spherical aberration is the only on-axis monochromatic aberration and can be used as a criterion to assess the degree of resemblance of eye models to the human eye. We reviewed and compiled experimental values of the spherical aberration of the eye, calculated the spherical aberration of several different categories of model eyes and compared the calculated results to the experimental data. Results show an over-estimation of spherical aberration by all models, the finite schematic eyes predicting values of spherical aberration closest to the experimental data. Current model eyes do not predict the average experimental values of the spherical aberration of the eye. A new model eye satisfying this assessment criterion is required for investigations of the visual performance of the eye.

  3. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  4. Theoretical investigation of aberrations upon ametropic human eyes

    Science.gov (United States)

    Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin

    2003-11-01

    The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.

  5. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  6. Role of androgen excess on metabolic aberrations and cardiovascular risk in women with polycystic ovary syndrome.

    Science.gov (United States)

    Christakou, Charikleia D; Diamanti-Kandarakis, Evanthia

    2008-11-01

    Polycystic ovary syndrome (PCOS) is associated with a clustering of metabolic and cardiovascular risk factors. Insulin resistance is implicated as the major player in the metabolic abnormalities and contributes to the increased cardiovascular risk associated with the syndrome. However, androgen excess appears to participate as an independent parameter, which further aggravates the cardiovascular and metabolic aberrations in affected women with PCOS. The resultant impact of hyperandrogenemia possibly acquires clinical significance for women's health in the context of PCOS, particularly since recent data support an increased incidence of coronary artery disease and of cardiovascular events directly related to androgen levels in women with the syndrome.

  7. Ocular higher-order aberrations in a school children population

    Directory of Open Access Journals (Sweden)

    George Papamastorakis

    2015-04-01

    Conclusions: Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development.

  8. Hepatic Arterial Configuration in Relation to the Segmental Anatomy of the Liver; Observations on MDCT and DSA Relevant to Radioembolization Treatment

    International Nuclear Information System (INIS)

    Hoven, Andor F. van den; Leeuwen, Maarten S. van; Lam, Marnix G. E. H.; Bosch, Maurice A. A. J. van den

    2015-01-01

    PurposeCurrent anatomical classifications do not include all variants relevant for radioembolization (RE). The purpose of this study was to assess the individual hepatic arterial configuration and segmental vascularization pattern and to develop an individualized RE treatment strategy based on an extended classification.MethodsThe hepatic vascular anatomy was assessed on MDCT and DSA in patients who received a workup for RE between February 2009 and November 2012. Reconstructed MDCT studies were assessed to determine the hepatic arterial configuration (origin of every hepatic arterial branch, branching pattern and anatomical course) and the hepatic segmental vascularization territory of all branches. Aberrant hepatic arteries were defined as hepatic arterial branches that did not originate from the celiac axis/CHA/PHA. Early branching patterns were defined as hepatic arterial branches originating from the celiac axis/CHA.ResultsThe hepatic arterial configuration and segmental vascularization pattern could be assessed in 110 of 133 patients. In 59 patients (54 %), no aberrant hepatic arteries or early branching was observed. Fourteen patients without aberrant hepatic arteries (13 %) had an early branching pattern. In the 37 patients (34 %) with aberrant hepatic arteries, five also had an early branching pattern. Sixteen different hepatic arterial segmental vascularization patterns were identified and described, differing by the presence of aberrant hepatic arteries, their respective vascular territory, and origin of the artery vascularizing segment four.ConclusionsThe hepatic arterial configuration and segmental vascularization pattern show marked individual variability beyond well-known classifications of anatomical variants. We developed an individualized RE treatment strategy based on an extended anatomical classification

  9. Case report

    African Journals Online (AJOL)

    abp

    27 avr. 2016 ... Dysphagia revealing aberrant right subclavian artery: about a case. Abdelilah Mouhsine1,&, Oualid Bakzaza2, El Mehdi Atmane1, Ahmed Belkouch3, Redouane Rokhssi1, Youssef Berrada1, Mostapha. Alaoui2, M'barek Mahfoudi1, Abdelghani El Fikri1. 1Service de Radiologie, HMA, Marrakech, Maroc, ...

  10. Dysphagia lusoria - report of 2 cases and a review of the literature ...

    African Journals Online (AJOL)

    Aberrant subclavian artery is the most frequent aortic arch anomaly and occurs in 0.5% of normal individuals.1,2 The majority of people with this anomaly are asymptomatic and nothing needs to be done. However, cervicomediastinal surgery for unrelated conditions predisposes patients to potential morbidity and even fatal ...

  11. Penile artery shunt syndrome: a novel cause of erectile dysfunction after penile revascularization surgery.

    Science.gov (United States)

    Pavlinec, Jonathan G; Hakky, Tariq S; Yang, Christopher; Massis, Kamal; Munarriz, Ricardo; Carrion, Rafael E

    2014-09-01

    Penile revascularization is a surgical treatment option for erectile dysfunction (ED) in healthy individuals due to a focal arterial occlusion in the absence of generalized vascular disease. Most described failures have been attributed to graft stenosis or disruption of the anastomosis. We report a novel phenomenon called Penile Artery Shunt Syndrome that contributed to persistent ED in a patient after penile microvascular arterial bypass surgery. A 26-year-old man presented for evaluation of long-standing ED, which was attributed to trauma sustained 12 years earlier. He had difficulty obtaining and maintaining erections despite oral pharmacotherapy. Clinical data related to the case were studied, analyzed, and reviewed with urologic and radiologic specialists at multiple centers that collaborated in the care of this patient. Penile duplex ultrasound peak systolic velocities and five-item International Index for Erectile Function questionnaire scores were the main outcome measures. Initial diagnostic workup of the patient confirmed severe insufficiency of the left cavernosal artery, with no evidence of venous leak. The patient underwent penile microvascular arterial bypass surgery with anastomosis of the left inferior epigastric artery to the left dorsal penile artery. The patient had persistence of severe ED despite patent anastomosis by penile duplex ultrasound. Subsequent arteriography revealed an arterial shunt due to an aberrant obturator artery arising from the donor inferior epigastric artery. The patient underwent embolization of the aberrant obturator artery, with resolution of the shunt and marked improvement in erectile function. The presence of an aberrant obturator artery arising from the inferior epigastric artery may predispose to persistent ED after revascularization due to the creation of a shunt phenomenon. Pelvic arteriography may be useful in identifying anomalous anatomic considerations prior to penile revascularization and to evaluate patients

  12. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  13. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  14. Assessing the construct validity of aberrant salience

    Directory of Open Access Journals (Sweden)

    Kristin Schmidt

    2009-12-01

    Full Text Available We sought to validate the psychometric properties of a recently developed paradigm that aims to measure salience attribution processes proposed to contribute to positive psychotic symptoms, the Salience Attribution Test (SAT. The “aberrant salience” measure from the SAT showed good face validity in previous results, with elevated scores both in high-schizotypy individuals, and in patients with schizophrenia suffering from delusions. Exploring the construct validity of salience attribution variables derived from the SAT is important, since other factors, including latent inhibition/learned irrelevance, attention, probabilistic reward learning, sensitivity to probability, general cognitive ability and working memory could influence these measures. Fifty healthy participants completed schizotypy scales, the SAT, a learned irrelevance task, and a number of other cognitive tasks tapping into potentially confounding processes. Behavioural measures of interest from each task were entered into a principal components analysis, which yielded a five-factor structure accounting for ~75% percent of the variance in behaviour. Implicit aberrant salience was found to load onto its own factor, which was associated with elevated “Introvertive Anhedonia” schizotypy, replicating our previous finding. Learned irrelevance loaded onto a separate factor, which also included implicit adaptive salience, but was not associated with schizotypy. Explicit adaptive and aberrant salience, along with a measure of probabilistic learning, loaded onto a further factor, though this also did not correlate with schizotypy. These results suggest that the measures of learned irrelevance and implicit adaptive salience might be based on similar underlying processes, which are dissociable both from implicit aberrant salience and explicit measures of salience.

  15. Study of radiation-induced chromosomal aberrations

    International Nuclear Information System (INIS)

    Wolfring, E.

    2004-06-01

    A method for determining chromosomal aberrations was established for the purpose of examining the relative biological effectiveness (RBE) of photon radiation with respect to mammary epithelium cells. Cells were exposed to 25 kV X-radiation and to 200 kV X-radiation for comparison and the resulting concentrations of chromosomal aberrations were compared. The RBE M value for radiation-induced fragmentation was found to be 4.2 ± 2.4, while the RBE M value for radiation-induced generation of dicentric chromosomes was found to be 0.5 ± 0.5. In addition to the evaluation of chromosomal aberrations the number of cell cycles undergone by the cells was monitored by means of BrDU staining. As expected, the proportion of cells which underwent more than one cell cycle following exposure to 5 Gy was very low in both cases, amounting to 1.9% (25 kV) and 3.2 (200 kV). Non-radiated cells yielded control values of 26.0% and 12.6%, suggesting variations in external conditions from day to day

  16. Chromosome aberration assays in barley (Hordeum vulgare)

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, M J [Univ. of Tennessee, Knoxville; Nilan, R A

    1982-01-01

    Barley is an exceellent organism for studies of induced chromosome aberrations because of its few (2n = 2x = 14) relatively large chromosomes. Root-tip and shoot-tip cells have been used extensively for the study of ionizing radiation-induced chromosome aberrations. The general procedures are well known, the technology is simple and easy to learn, and the assays are relatively quick and inexpensive. Both root tips and shoot tips can be used for the study of chemical mutagens as well as ionizing radiations. Pollen mother cells are well suited for studying the effects of mutagens on meiotic chromosomes. The literature review for the Gene-Tox Program reported on 61 chemicals tested for their effects on barley chromosomes. Of these, 90% were reported to be either positive or positive dose-related, while 7% were negative and 3% were questionable. Barley assays based on chromosomal aberrations are useful to detect the clastogenic potency of chemicals under laboratory conditions. Indications are that the data from barley can be used to corroborate data obtained from other organisms. Among the classes of chemicals assayed were: alcohols and phenols; alkaloids; epoxides; alkyl sulfates; amides and sulfonamides; aromatic amines; aryl halides; aziridines; alkenes; carbamates; hydroazides; nitroaromatics; nitrosamides; nitrosources; phenothiazines; and polycyclic aromatic hydrocarbons.

  17. Aberrant phenotypes in peripheral T cell lymphomas.

    Science.gov (United States)

    Hastrup, N; Ralfkiaer, E; Pallesen, G

    1989-01-01

    Seventy six peripheral T cell lymphomas were examined immunohistologically to test their reactivity with a panel of monoclonal antibodies against 11 T cell associated antigens (CD1-8, CD27, UCHL1, and the T cell antigen receptor). Sixty two (82%) lymphomas showed aberrant phenotypes, and four main categories were distinguished as follows: (i) lack of one or several pan-T cell antigens (49, 64% of the cases); (ii) loss of both the CD4 and CD8 antigens (11, 15% of the cases); (iii) coexpression of the CD4 and CD8 antigens (13, 17% of the cases); and (iv) expression of the CD1 antigen (eight, 11% of the cases). No correlation was seen between the occurrence of aberrant phenotypes and the histological subtype. It is concluded that the demonstration of an aberrant phenotype is a valuable supplement to histological assessment in the diagnosis of peripheral T cell lymphomas. It is recommended that the panel of monoclonal antibodies against T cell differentiation antigens should be fairly large, as apparently any antigen may be lost in the process of malignant transformation. Images Figure PMID:2469701

  18. Severe epistaxis due to aberrant vasculature in a patient with STAT-1 mutation.

    Science.gov (United States)

    Chang, Michael T; Schwam, Zachary G; Hajek, Michael A; Paskhover, Boris; Judson, Benjamin L

    2016-03-01

    Signal transducer and activator 1 (STAT-1) mutations are rare and have been implicated in combined immunodeficiency, enhanced tumorigenesis, and vascular defects. A 60-year-old woman with a novel STAT-1 mutation and resulting immunodeficiency, squamous cell carcinoma, and vascular disease presented with profuse epistaxis secondary to rupture of an aberrant artery that she developed in part because of this mutation. After unsuccessful posterior packing, embolization was initiated but subsequently aborted because of a bovine origin carotid artery and a history of multiple carotid dissections. After repeat posterior packing, hemostasis was achieved. No additional episodes of epistaxis occurred in the subsequent 13 months. Vascular anomalies can present challenges in epistaxis management. In patients with conditions known to cause vascular anomalies, it is critical to obtain vascular imaging before intervention. © 2015 Wiley Periodicals, Inc.

  19. The effect of lung deflation on the position of the pleura during subclavian vein cannulation in infants receiving mechanical ventilation: an ultrasound study.

    Science.gov (United States)

    Jang, Y-E; Lee, J-H; Park, Y-H; Byon, H-J; Kim, H-S; Kim, C-S; Kim, J-T

    2013-10-01

    We evaluated the effect of lung deflation on the relative position of the pleura compared with a reference line during supra- and infraclavicular approaches to the right subclavian vein. The reference line was drawn relative to the predicted pathway of the needle. The distances between the pleura and the reference line for supra- and infraclavicular approaches were measured during inspiration and expiration in 41 infants. Measurements were repeated with the application of 5 cmH2O positive end-expiratory pressure (PEEP) and in the Trendelenburg position. Lung deflation during the supraclavicular approach significantly decreased the volume of lung crossing the reference line by a median (IQR [range]) of 1.0 (0.6 to 1.3 [0.0 to 4.8]) mm, p deflation showed no change in the distance of the pleura from the reference line regardless of PEEP or patient position. We conclude that lung deflation moves the lung apex caudally and can reduce the potential risk of pneumothorax during a supraclavicular approach to the right subclavian vein in infants. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  20. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. Nodal aberration theory for wild-filed asymmetric optical systems

    Science.gov (United States)

    Chen, Yang; Cheng, Xuemin; Hao, Qun

    2016-10-01

    Nodal Aberration Theory (NAT) was used to calculate the zero field position in Full Field Display (FFD) for the given aberration term. Aiming at wide-filed non-rotational symmetric decentered optical systems, we have presented the nodal geography behavior of the family of third-order and fifth-order aberrations. Meanwhile, we have calculated the wavefront aberration expressions when one optical element in the system is tilted, which was not at the entrance pupil. By using a three-piece-cellphone lens example in optical design software CodeV, the nodal geography is testified under several situations; and the wavefront aberrations are calculated when the optical element is tilted. The properties of the nodal aberrations are analyzed by using Fringe Zernike coefficients, which are directly related with the wavefront aberration terms and usually obtained by real ray trace and wavefront surface fitting.

  2. DNA Repair Defects and Chromosomal Aberrations

    Science.gov (United States)

    Hada, Megumi; George, K. A.; Huff, J. L.; Pluth, J. M.; Cucinotta, F. A.

    2009-01-01

    Yields of chromosome aberrations were assessed in cells deficient in DNA doublestrand break (DSB) repair, after exposure to acute or to low-dose-rate (0.018 Gy/hr) gamma rays or acute high LET iron nuclei. We studied several cell lines including fibroblasts deficient in ATM (ataxia telangiectasia mutated; product of the gene that is mutated in ataxia telangiectasia patients) or NBS (nibrin; product of the gene mutated in the Nijmegen breakage syndrome), and gliomablastoma cells that are proficient or lacking in DNA-dependent protein kinase (DNA-PK) activity. Chromosomes were analyzed using the fluorescence in situ hybridization (FISH) chromosome painting method in cells at the first division post irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). Gamma irradiation induced greater yields of both simple and complex exchanges in the DSB repair-defective cells than in the normal cells. The quadratic dose-response terms for both simple and complex chromosome exchanges were significantly higher for the ATM- and NBS-deficient lines than for normal fibroblasts. However, in the NBS cells the linear dose-response term was significantly higher only for simple exchanges. The large increases in the quadratic dose-response terms in these repair-defective cell lines points the importance of the functions of ATM and NBS in chromatin modifications to facilitate correct DSB repair and minimize the formation of aberrations. The differences found between ATM- and NBS-deficient cells at low doses suggest that important questions should with regard to applying observations of radiation sensitivity at high dose to low-dose exposures. For aberrations induced by iron nuclei, regression models preferred purely linear dose responses for simple exchanges and quadratic dose responses for complex exchanges. Relative biological effectiveness (RBE) factors of all of

  3. CT assessment of tracheobronchial anomaly in left pulmonary artery sling

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min M.; Zhu, Ming; Sun, Ai-Min M.; Wang, Qian [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Gao, Wei [Shanghai Jiao Tong University School of Medicine, Department of Cardiology, Shanghai Children' s Medical Center, Shanghai (China)

    2010-11-15

    The left pulmonary artery sling (LPAS) is a rare vascular anomaly where the left pulmonary artery arises from the right pulmonary artery, passes over the right bronchus, and goes posteriorly between the trachea and esophagus. The LPAS is frequently associated with cardiac and non-cardiac defects including tracheobronchial abnormalities. To evaluate the utility of multislice CT (MSCT) and helical CT (HCT) in diagnosing and defining the tracheobronchial anomaly and anatomic relationships between the trachea and aberrant left pulmonary artery. MSCT or HCT was performed in 27 children to determine the tracheobronchial anatomy and identify tracheobronchial stenosis. Eighteen children underwent surgery. According to the Wells [6] classification of LPAS, which includes two main types and two subtypes, there were eight cases of type 1A, five cases of type 1B, six cases of type 2A and eight cases of type 2B in this group. Twenty-four of the 27 children had substantial tracheobronchial stenosis. Four died before surgery; the 18 had reanastomosis of the left pulmonary artery. Five children also had tracheoplasty; three died after surgery. CT, especially MSCT, is an ideal modality for simultaneously identifying aberrant left pulmonary artery and any associated tracheobronchial anomaly. The Wells classification is useful for operative planning. (orig.)

  4. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  5. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  6. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  7. Renal artery origins and variations: angiographic evaluation of 855 consecutive patients.

    Science.gov (United States)

    Ozkan, Uğur; Oğuzkurt, Levent; Tercan, Fahri; Kizilkiliç, Osman; Koç, Zafer; Koca, Nihal

    2006-12-01

    To determine angiographically the origins and variations of renal arteries. The study included 855 consecutive patients (163 females, 692 males; mean age, 61 years) living in the Cukurova region of Turkey, who underwent either aortofemoropopliteal (AFP) angiography for the investigation of peripheral arterial disease, or renal angiography for renovascular hypertension, and were prospectively evaluated. Renal arteries were visualized by non-selective catheterization during AFP angiography and by selective or non-selective catheterization during renal angiography. Locations of renal artery origins and renal artery variations, including the presence of extra renal arteries and division patterns were analyzed on angiograms. The origin of main renal arteries off the aorta was between the upper margin of L1 and lower margin of L2 vertebra in 98% of the patients, and in 74%, this was the origin of extra renal arteries. The most common location for renal artery origin was the L1-L2 intervertebral disc level. A single renal artery was present in both kidneys in 76% of patients. Renal artery variations included multiple arteries in 24%, bilateral multiple arteries in 5%, and early division in 8% of the cases. Additional renal arteries on the right side were found in 16% and on the left side in 13% of cases. Of all the extra renal arteries, the percentage of accessory and aberrant renal arteries were 49% and 51%, respectively. Renal arteries originated between the first and the second lumbar vertebral levels in most patients. Extra renal arteries were quite frequent. These results should be kept in mind when a non-invasive diagnostic search is performed for renal artery stenosis, or when renal surgery related to renal arteries is performed.

  8. Survival and transmission of symmetrical chromosomal aberrations

    International Nuclear Information System (INIS)

    Savage, J.R.K.

    1979-01-01

    The interaction between the lesions to produce chromosomal structural changes may be either asymmetrical (A) or symmetrical (S). In A, one or more acentric fragments are always produced, and there may also be the mechanical separation problems resulting from bridges at anaphase, while S-changes never produce fragment, and pose no mechanical problem in cell division. If A and S events occur with equal frequency, it might be an indication that they are truly the alternative modes of lesion interaction. Unstimulated lymphocytes were irradiated with 2.68 Gy 250 kV X-ray, and metaphases were sampled at 50 h after the stimulation. Preparations were complete diploid cells, and any obvious second division cells were rejected. So far as dermal repair and fibroblast functions are concerned, aberration burden seems to have little consequence from the view-point of the long-term survival in vivo. Large numbers of aberrations (mainly S translocation and terminal deletion) were found in the samples taken up to 60 years after therapy. Skin biopsies were removed 1 day and 6 months after irradiation and cultured. In irradiated cells, reciprocal translocations dominated, followed by terminal deletions, then inversions, while no chromosome-type aberration was seen in the control cells. a) The relative occurrence of A : S changes, b) long-term survival in vivo, c) the possibility of in vivo repair, and d) some unusual features of translocation found in Syrian hamsters are reviewed. The relevance or importance of major S events is clearly dependent upon the cells, the tissues or the organisms in which they occur. (Yamashita, S.)

  9. Clinical significance of inter-arm pressure difference and ankle-brachial pressure index in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Igarashi, Yuko; Chikamori, Taishiro; Tomiyama, Hirofumi; Usui, Yasuhiro; Hida, Satoshi; Tanaka, Hirokazu; Nagao, Tadashi; Yamashina, Akira

    2007-01-01

    Although measuring blood pressure at the bilateral brachia is common in medical practice, its clinical significance in patients with suspected coronary artery disease (CAD) has not been fully clarified. The method of this study was to define the significance of inter-arm systolic blood pressure difference in patients with suspected CAD, and to assess the relationship between inter-arm pressure difference and CAD, simultaneous brachial and ankle blood pressure measurements and stress myocardial single-photon emission computed tomography (SPECT) were performed in 386 consecutive patients with suspected CAD, excluding those with previous myocardial infarction or coronary revascularization. Subclavian artery stenosis, defined as ≥15 mmHg inter-arm systolic blood pressure difference, was found in 27 patients (7%). Age (65±12 vs 65±11 years), male sex (21/27 vs 244/359), prevalence of hypertension (63% vs 56%), hypercholesterolemia (63% vs 62%), diabetes mellitus (33% vs 38%), cigarette smoking (44% vs 41%) and family history of CAD (15% vs 12%) were similar between patients with subclavian artery stenosis and those without. The incidence of decreased ankle-brachial pressure index (ABI) was higher (37% vs 12%, p=0.001), and percentage ischemic myocardium as assessed by SPECT was greater (9.0±8.5% vs 5.6±6.6%, p=0.05) in patients with subclavian artery stenosis than in those without. Furthermore, significant correlations were observed between inter-arm pressure difference and percentage ischemic myocardium (r=0.13; p=0.01), and ABI (r=-0.26, p<0.0001). Among 386 patients, 283 underwent coronary angiography, and 63% of those who had inter-arm blood pressure difference had CAD. Furthermore, 83% of those CAD patients had multi-vessel CAD, which is regarded as a high-risk subset for subsequent cardiac events. Inter-arm pressure difference is often found in patients with suspected CAD, and is associated with significant CAD and peripheral artery disease. Thus, inter

  10. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  11. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  12. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  13. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  14. Eye aberration analysis with Zernike polynomials

    Science.gov (United States)

    Molebny, Vasyl V.; Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.

    1998-06-01

    New horizons for accurate photorefractive sight correction, afforded by novel flying spot technologies, require adequate measurements of photorefractive properties of an eye. Proposed techniques of eye refraction mapping present results of measurements for finite number of points of eye aperture, requiring to approximate these data by 3D surface. A technique of wave front approximation with Zernike polynomials is described, using optimization of the number of polynomial coefficients. Criterion of optimization is the nearest proximity of the resulted continuous surface to the values calculated for given discrete points. Methodology includes statistical evaluation of minimal root mean square deviation (RMSD) of transverse aberrations, in particular, varying consecutively the values of maximal coefficient indices of Zernike polynomials, recalculating the coefficients, and computing the value of RMSD. Optimization is finished at minimal value of RMSD. Formulas are given for computing ametropia, size of the spot of light on retina, caused by spherical aberration, coma, and astigmatism. Results are illustrated by experimental data, that could be of interest for other applications, where detailed evaluation of eye parameters is needed.

  15. Aberrant Myokine Signaling in Congenital Myotonic Dystrophy

    Directory of Open Access Journals (Sweden)

    Masayuki Nakamori

    2017-10-01

    Full Text Available Summary: Myotonic dystrophy types 1 (DM1 and 2 (DM2 are dominantly inherited neuromuscular disorders caused by a toxic gain of function of expanded CUG and CCUG repeats, respectively. Although both disorders are clinically similar, congenital myotonic dystrophy (CDM, a severe DM form, is found only in DM1. CDM is also characterized by muscle fiber immaturity not observed in adult DM, suggesting specific pathological mechanisms. Here, we revealed upregulation of the interleukin-6 (IL-6 myokine signaling pathway in CDM muscles. We also found a correlation between muscle immaturity and not only IL-6 expression but also expanded CTG repeat length and CpG methylation status upstream of the repeats. Aberrant CpG methylation was associated with transcriptional dysregulation at the repeat locus, increasing the toxic RNA burden that upregulates IL-6. Because the IL-6 pathway is involved in myocyte maturation and muscle atrophy, our results indicate that enhanced RNA toxicity contributes to severe CDM phenotypes through aberrant IL-6 signaling. : Congenital myotonic dystrophy (CDM manifests characteristic genetic (very large CTG repeat expansions, epigenetic (CpG hypermethylation upstream of the repeat, and phenotypic (muscle immaturity features not seen in adult DM. Nakamori et al. find phenotype-genotype and epigenotype correlation in CDM muscle and reveal involvement of the IL-6 myokine signaling pathway in the disease process. Keywords: CTCF, ER stress, IL-6, muscular dystrophy, NF-κB, trinucleotide, cytokine, splicing

  16. Higher order aberrations of the eye: Part one

    Directory of Open Access Journals (Sweden)

    Marsha Oberholzer

    2016-06-01

    Full Text Available This article is the first in a series of two articles that provide a comprehensive literature review of higher order aberrations (HOAs of the eye. The present article mainly explains the general principles of such HOAs as well as HOAs of importance, and the measuring apparatus used to measure HOAs of the eye. The second article in the series discusses factors contributing to variable results in measurements of HOAs of the eye. Keywords: Higher order aberrations; wavefront aberrations; aberrometer

  17. Chromosomal aberrations in children exposed to diagnostic x-rays

    International Nuclear Information System (INIS)

    Nordenson, I.; Beckman, G.; Beckman, L.; Lemperg, R.

    1980-01-01

    Among children who have received high x-ray doses congenital dislocation of the hip joint is the predominating diagnosis. In a series of 9 children who had received high x-ray doses (8 with luxation of the hip joint and one with achondroplasia) a significant increase of chromosomal aberrations was found. The increase concerned mainly chromosome type aberrations. The shorter the time since the last x-ray investigation the higher was the frequency of chromosome type aberrations. (author)

  18. Third-rank chromatic aberrations of electron lenses.

    Science.gov (United States)

    Liu, Zhixiong

    2018-02-01

    In this paper the third-rank chromatic aberration coefficients of round electron lenses are analytically derived and numerically calculated by Mathematica. Furthermore, the numerical results are cross-checked by the differential algebraic (DA) method, which verifies that all the formulas for the third-rank chromatic aberration coefficients are completely correct. It is hoped that this work would be helpful for further chromatic aberration correction in electron microscopy. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Higher order monochromatic aberrations of the human infant eye

    OpenAIRE

    Wang, Jingyun; Candy, T. Rowan

    2005-01-01

    The monochromatic optical aberrations of the eye degrade retinal image quality. Any significant aberrations during postnatal development could contribute to infants’ immature visual performance and provide signals for the control of eye growth. Aberrations of human infant eyes from 5 to 7 weeks old were compared with those of adult subjects using a model of an adultlike infant eye that accounted for differences in both eye and pupil size. Data were collected using the COAS Shack-Hartmann wave...

  20. Maternal arterial elasticity in the first trimester as a predictor of birthweight.

    Science.gov (United States)

    O'Connor, Clare; O'Higgins, Amy; Segurado, Ricardo; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2016-07-01

    The early detection of foetal growth restriction and macrosomia is an important goal of modern obstetric care. Aberrant foetal growth is an important cause of perinatal morbidity and mortality. Current modalities for detecting the abnormal foetal growth are often inadequate. Pulse wave analysis using applanation tonometry is a simple and non-invasive test that provides information about the cardiovascular system. Arterial elasticity has previously been implicated in the pathophysiology of pre-eclampsia and cardiovascular disease. Our study examined the relationship between maternal arterial elasticity and birthweight by using pulse wave analysis. We discovered that increased large artery elasticity predicted a larger baby at birth. Large artery elasticity therefore has the potential to act as a useful screening tool which may help in the prediction of women who are at risk of aberrant foetal growth.

  1. CORONARY ARTERY FISTULA: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    MZ Chowdhury

    2007-01-01

    Full Text Available The prevalence of congenital abnormalities of coronary artery is about 2% of general population. Of these abnormalities 5% were related to coronary artery fistulae (CAF. We report a case of 66 year old diabetic woman who presented with retrosternal chest pain. Her chest pain was associated with exercise and progressively deteriorated over the last 6 months. Electrocardiography showed right bundle branch block and Echo Color Doppler revealed hypo kinetic lateral wall. Coronary angiogram detected nothing abnormal except an aberrant tortuous branch of left circumflex. CT scan revealed a calcified sac medial to the descended thoracic aorta. A contrast enhancement was also done. All these imaging impressions were suggestive of coronary-to-pulmonary fistula. Ibrahim Med. Coll. J. 2007; 1(1: 32-33

  2. Whole eye wavefront aberrations in Mexican male subjects.

    Science.gov (United States)

    Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio

    2004-01-01

    To analyze the characteristics, incidence, and appearance of wavefront aberrations in undilated, normal, unoperated eyes. Eighty-eight eyes of 44 healthy male Mexican subjects (mean age 25.32 years, range 18 to 36 yr) were divided into three groups based on uncorrected visual acuity of greater than or equal to 20/20, 20/30, or 20/40. UCVA measurements were obtained using an Acuity Max computer screen chart. Wavefront aberrations were measured with the Nidek OPD-Scan ARK 10000, Ver. 1.11b. All measurements were carried out at the same center by the same technician during a single session, following manufacturer instructions. Background illumination was 3 Lux. Wavefront aberration measurements for each group were statistically analyzed using StatView; an average eye was characterized and the resulting aberrations were simulated using MATLAB. We obtained wavefront aberration maps for the 20/20 undilated normal unoperated eyes for total, low, and high order aberration coefficients. Wavefront maps for right eyes were practically the same as those for left eyes. Higher aberrations did not contribute substantially to total wavefront analysis. Average aberrations of this "normal eye" will be used as criteria to decide the necessity of wavefront-guided ablation in our facilities. We will focus on the nearly zero average of high order aberrations in this normal whole eye as a reference to be matched.

  3. Radiation-induced chromosome aberrations in the rat peripheral blood

    International Nuclear Information System (INIS)

    Ziemba-Zoltowska, B.; Bocian, E.; Radwan, I.; Rosiek, O.; Sablinski, J.

    1978-01-01

    Chromosome aberrations in rat lymphocytes of peripheral blood after X (in vitro and in vivo) and 3 H tritiated water (in vivo) irradiations were studied. The yield of chromosome aberrations after in vivo and in vitro exposure to X-rays was similar. The frequency of chromosome aberrations three weeks after exposure to X-rays and soon after irradiation was practically on the same level. The yield of chromosome aberrations determined three weeks after injection with tritiated water or X-rays exposure was similar. (author)

  4. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  5. Chromosome aberration analysis for biological dosimetry: a review

    International Nuclear Information System (INIS)

    Paul, S.F.D.; Venkatachalam, P.; Jeevanram, R.K.

    1996-01-01

    Among various biological dosimetry techniques, dicentric chromosome aberration method appears to be the method of choice in analysing accidental radiation exposure in most of the laboratories. The major advantage of this method is its sensitivity as the number of dicentric chromosomes present in control population is too small and more importantly radiation induces mainly dicentric chromosome aberration among unstable aberration. This report brings out the historical development of various cytogenetic methods, the basic structure of DNA, chromosomes and different forms of chromosome aberrations. It also highlights the construction of dose-response curve for dicentric chromosome and its use in the estimation of radiation dose. (author)

  6. Imaging characteristics of Zernike and annular polynomial aberrations.

    Science.gov (United States)

    Mahajan, Virendra N; Díaz, José Antonio

    2013-04-01

    The general equations for the point-spread function (PSF) and optical transfer function (OTF) are given for any pupil shape, and they are applied to optical imaging systems with circular and annular pupils. The symmetry properties of the PSF, the real and imaginary parts of the OTF, and the modulation transfer function (MTF) of a system with a circular pupil aberrated by a Zernike circle polynomial aberration are derived. The interferograms and PSFs are illustrated for some typical polynomial aberrations with a sigma value of one wave, and 3D PSFs and MTFs are shown for 0.1 wave. The Strehl ratio is also calculated for polynomial aberrations with a sigma value of 0.1 wave, and shown to be well estimated from the sigma value. The numerical results are compared with the corresponding results in the literature. Because of the same angular dependence of the corresponding annular and circle polynomial aberrations, the symmetry properties of systems with annular pupils aberrated by an annular polynomial aberration are the same as those for a circular pupil aberrated by a corresponding circle polynomial aberration. They are also illustrated with numerical examples.

  7. Chromosome aberrations: plants to human and Feulgen to FISH

    International Nuclear Information System (INIS)

    Natarajan, A.T.

    2005-01-01

    Chromosome aberrations and their impact on human health have been recognized for a long time. In the 1950s, in India, studies on induced chromosome aberrations in plants were initiated by Swaminathan and his students. I trace here the impact of these initial studies on further developments in this field. The studies which were started in plants have been extended to mammals (including human) and the simple squash and solid staining have been improved by molecular cytogenetic techniques, thus enabling accurate identification and quantification of different types of chromosome aberrations. These studies have also thrown light on the mechanisms of chromosome aberration formation, especially following exposure to ionizing radiation. (author)

  8. Echocolor Doppler morpho-functional study of the jugulo-subclavian confluence in chronic cerebro-spinal venous insufficiency and multiple sclerosis patients.

    Science.gov (United States)

    Mandolesi, Sandro; d'Alessandro, Aldo; Desogus, Antonello Ignazio; Ciccone, Marco Matteo; Zito, Annapaola; Stammegna, Immacolata; Niglio, Tarcisio; Orsini, Augusto; Mandolesi, Dimitri; d'Alessandro, Alessandro; Revelli, Luca

    2017-01-01

    The aim of this work is to measure the mean diameter of the confluence jugulo- subclavian, the impact of different types of jugular confluences and the correlation between the types of confluences and the Valsalva maneuver (jugular reflux) in subjects with Chronic Cerebro-Spinal Venous Insufficiency (CCSVI) and Multiple Sclerosis. We investigated by Echo-Color-Doppler (ECD) 103 subjects (67 F 36M) of mean age 45 ± 12 years (a minimum of 22 to a maximum of 79 years, with a median of 44 and a modal value 42 years), mean EDSS of 4.7 and average disease duration of 12 years. The 103 right jugular veins investigated had an average diameter of 8.4 ± 2.4 mm (minimum 4.0, maximum 14.9 mm; median 7.9; modal value 7.6 mm). Three form types were found: 56 cylindrical, 29 conical and 18 funnel. Valsalva maneuver was positive in 30 patients. The 103 left jugular investigated had an average diameter of 8.9 ± 2.4 mm (minimum 2.8, maximum 14.4 mm; median of 8.8; modal value 8.7 mm). The form types were found: 42 cylindrical, 45 conical and 16 funnel. Valsalva maneuver was positive in 30 patients. The mean diameter of the jugular veins was 8.7 mm. Internal jugular veins with cylindrical morphology have a diameter smaller than other forms; this difference is statistically significant. The different morphology of the jugular vein confluence does not increase the possibility of a reflux because the positive Valsalva maneuvers are not statistically significant when compared to the various types. CCSVI, EchoColorDoppler Map, Jugulo-Subclavian Confluence Diameter.

  9. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  10. Adaptive aberration correction using a triode hyperbolic electron mirror

    International Nuclear Information System (INIS)

    Fitzgerald, J.P.S.; Word, R.C.; Koenenkamp, R.

    2011-01-01

    A converging electron mirror can be used to compensate spherical and chromatic aberrations in an electron microscope. This paper presents an analytical solution to a novel triode (three electrode) hyperbolic mirror as an improvement to the well-known diode (two electrode) hyperbolic mirror for aberration correction. A weakness of the diode mirror is a lack of flexibility in changing the chromatic and spherical aberration coefficients independently without changes in the mirror geometry. In order to remove this limitation, a third electrode can be added. We calculate the optical properties of the resulting triode mirror analytically on the basis of a simple model field distribution. We present the optical properties-the object/image distance, z 0 , and the coefficients of spherical and chromatic aberration, C s and C c , of both mirror types from an analysis of electron trajectories in the mirror field. From this analysis, we demonstrate that while the properties of both designs are similar, the additional parameters in the triode mirror improve the range of aberration that can be corrected. The triode mirror is also able to provide a dynamic adjustment range of chromatic aberration for fixed spherical aberration and focal length, or any permutation of these three parameters. While the dynamic range depends on the values of aberration correction needed, a nominal 10% tuning range is possible for most configurations accompanied by less than 1% change in the other two properties. -- Highlights: → Electrostatic aberration correction for chromatic and spherical aberration in electron optics. → Simultaneous correction of spherical and chromatic aberrations over a wide, adjustable range. → Analytic and quantitative description of correction parameters.

  11. Aberrant twinning (diprosopus) associated with anencephaly.

    Science.gov (United States)

    Moerman, P; Fryns, J P; Goddeeris, P; Lauweryns, J M; Van Assche, A

    1983-10-01

    A case of Monocephalus diprosopus, associated with craniorachischisis and duplication of most of the foregut derivates is presented. The major part of the cardiovascular system remained single but the heart exhibited severe defects, including a complete persistent atrioventricular canal, transposition of the great arteries and atresia of the pulmonary valve. This report further supports the hypothesis that certain-types of incomplete twinning and neural tube defects may be caused by a single teratogenic mechanism.

  12. Chromosome aberrations induced by radiation. With special reference to possible relation between chromosome aberrations and carcinogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kamada, N [Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology

    1980-02-01

    Chromosome aberration seems to be one of the most conspicuous residual abnormalities recognizable in radiation-exposed persons for many years after exposure. Knowledge of the biological significance of these abnormalities seems to be necessary for understanding of the effect of radiation on humans, especially in relation to possible leukemic development. Cytogenetic studies were performed on the bone marrow cells, T and B lymphocytes, and fibroblasts in atomic bomb-survivors who were in apparent good health (105 cases), atomic bomb exposed patients who had prolonged periods of blood disorders which terminated in acute leukemia (8 cases), and who had no such abnormalities (6 cases). All patients with chronic myelocytic leukemia (CML) and a history of atomic bomb exposure showed Philadelphia chromosome, a characteristic chromosome abnormality for CML. The persistent chromosome aberrations of bone marrow cells, T and B lymphocytes found among the atomic bomb survivors with or without blood disorders may give some clue to solve the problems of carcinogenesis.

  13. Fifth-order aberrations in magnetic quadrupole-octupole systems

    International Nuclear Information System (INIS)

    Ling, K.M.

    1990-01-01

    Explicit integral expressions are given for the fifth-order geometrical aberration coefficients in rectilinear magnetic quadrupole-octupole systems used for the transport of nonrelativistic charged particle beams. The numerical values of the fifth-order geometrical aberration coefficients for a rare earth cobalt (REC) quadrupole doublet are given as an example. 26 refs., 5 figs., 4 tabs

  14. An aberrant uterus: Case report | Ondieki | East African Medical ...

    African Journals Online (AJOL)

    A case of an aberrant uterus is presented and literature reviewed. The patient presented with abnormal uterine bleeding, left iliac fossa pain and was managed by excising the aberrant uterus. This case was an enigma as it didn't present in the classical way one with anomalies of the uterus would present. Despite ...

  15. Accuracy of modal wavefront estimation from eye transverse aberration measurements

    Science.gov (United States)

    Chyzh, Igor H.; Sokurenko, Vyacheslav M.

    2001-01-01

    The influence of random errors in measurement of eye transverse aberrations on the accuracy of reconstructing wave aberration as well as ametropia and astigmatism parameters is investigated. The dependence of mentioned errors on a ratio between the number of measurement points and the number of polynomial coefficients is found for different pupil location of measurement points. Recommendations are proposed for setting these ratios.

  16. Statistical estimation of ultrasonic propagation path parameters for aberration correction.

    Science.gov (United States)

    Waag, Robert C; Astheimer, Jeffrey P

    2005-05-01

    Parameters in a linear filter model for ultrasonic propagation are found using statistical estimation. The model uses an inhomogeneous-medium Green's function that is decomposed into a homogeneous-transmission term and a path-dependent aberration term. Power and cross-power spectra of random-medium scattering are estimated over the frequency band of the transmit-receive system by using closely situated scattering volumes. The frequency-domain magnitude of the aberration is obtained from a normalization of the power spectrum. The corresponding phase is reconstructed from cross-power spectra of subaperture signals at adjacent receive positions by a recursion. The subapertures constrain the receive sensitivity pattern to eliminate measurement system phase contributions. The recursion uses a Laplacian-based algorithm to obtain phase from phase differences. Pulse-echo waveforms were acquired from a point reflector and a tissue-like scattering phantom through a tissue-mimicking aberration path from neighboring volumes having essentially the same aberration path. Propagation path aberration parameters calculated from the measurements of random scattering through the aberration phantom agree with corresponding parameters calculated for the same aberrator and array position by using echoes from the point reflector. The results indicate the approach describes, in addition to time shifts, waveform amplitude and shape changes produced by propagation through distributed aberration under realistic conditions.

  17. Aberration analysis calculations for synchrotron radiation beamline design

    International Nuclear Information System (INIS)

    McKinney, W.R.; Howells, M.; Padmore, H.A.

    1997-09-01

    The application of ray deviation calculations based on aberration coefficients for a single optical surface for the design of beamline optical systems is reviewed. A systematic development is presented which allows insight into which aberration may be causing the rays to deviate from perfect focus. A new development allowing analytical calculation of line shape is presented

  18. Chromatic aberrations of two-electrode transaxial mirrors

    International Nuclear Information System (INIS)

    Bejzina, L.G.; Karetskaya, S.P.

    1991-01-01

    Second order chromatic aberrations of electrostatic two-electrode transaxial mirrors in case the beam axial trajectory of charged particles is curvilinear are considered. Interrelations between coefficients of linear and angular chromatic aberrations are determined. Values of these coefficients for concave and convex transaxial mirrors with plane electrodes in dependence on potential ratio on electrodes by different onnular clearance radii are presented

  19. Sextupole system for the correction of spherical aberration

    Science.gov (United States)

    Crewe, A.V.; Kopf, D.A.

    In an electron beam device in which an electron beam is developed and then focused by a lens to a particular spot, there is provided a means for eliminating spherical aberration. A sextupole electromagnetic lens is positioned between two focusing lenses. The interaction of the sextupole with the beam compensates for spherical aberration. (GHT)

  20. Third-order monochromatic aberrations via Fermat's principle

    International Nuclear Information System (INIS)

    Marasco, A.; Romano, A.

    2006-01-01

    By Fermat's principle and particular optical paths, which are not rays, a new aberration function is introduced. This function allows to derive, without resorting to the whole Hamiltonian formalism, the third-order geometrical aberrations of an optical system with a symmetry of revolution

  1. Chromosome aberration analysis based on a beta-binomial distribution

    International Nuclear Information System (INIS)

    Otake, Masanori; Prentice, R.L.

    1983-10-01

    Analyses carried out here generalized on earlier studies of chromosomal aberrations in the populations of Hiroshima and Nagasaki, by allowing extra-binomial variation in aberrant cell counts corresponding to within-subject correlations in cell aberrations. Strong within-subject correlations were detected with corresponding standard errors for the average number of aberrant cells that were often substantially larger than was previously assumed. The extra-binomial variation is accomodated in the analysis in the present report, as described in the section on dose-response models, by using a beta-binomial (B-B) variance structure. It is emphasized that we have generally satisfactory agreement between the observed and the B-B fitted frequencies by city-dose category. The chromosomal aberration data considered here are not extensive enough to allow a precise discrimination between competing dose-response models. A quadratic gamma ray and linear neutron model, however, most closely fits the chromosome data. (author)

  2. Chromosomal aberrations in bone marrow of continuously irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Chlebosky, O; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Prirodovedecka Fakulta

    1975-01-01

    Research on chromosomal aberrations of the bone marrow in continuously irradiated rats showed that chromosomal aberrations are a highly sensitive indicator of radiation injury. An increase in the chromosomal aberration frequency was already found on the 5th day at daily doses of 0.5 R, i.e. a 12% increase at a total dose of 25 R. In the steady-state stage at daily doses of 0.5; 1; 2.5 R, the number of chromosomal aberrations stabilized at values of about 20%; at daily doses of 5 and 10 R at values of 30.=., at daily doses of 53 R at 45%, at a daily dose of 82.5 R, the number of chromosomal aberrations increased to 55%.

  3. Image based method for aberration measurement of lithographic tools

    Science.gov (United States)

    Xu, Shuang; Tao, Bo; Guo, Yongxing; Li, Gongfa

    2018-01-01

    Information of lens aberration of lithographic tools is important as it directly affects the intensity distribution in the image plane. Zernike polynomials are commonly used for a mathematical description of lens aberrations. Due to the advantage of lower cost and easier implementation of tools, image based measurement techniques have been widely used. Lithographic tools are typically partially coherent systems that can be described by a bilinear model, which entails time consuming calculations and does not lend a simple and intuitive relationship between lens aberrations and the resulted images. Previous methods for retrieving lens aberrations in such partially coherent systems involve through-focus image measurements and time-consuming iterative algorithms. In this work, we propose a method for aberration measurement in lithographic tools, which only requires measuring two images of intensity distribution. Two linear formulations are derived in matrix forms that directly relate the measured images to the unknown Zernike coefficients. Consequently, an efficient non-iterative solution is obtained.

  4. Cell survival and radiation induced chromosome aberrations. Pt. 2

    International Nuclear Information System (INIS)

    Bauchinger, M.; Schmid, E.; Braselmann, H.

    1986-01-01

    Human peripheral lymphocytes were irradiated in whole blood with 0.5-4.0 Gy of 220 kVp X-rays and the frequency of chromosome aberrations was determined in 1st or 2nd division metaphases discriminated by fluorescence plus giemsa staining. Using the empirical distributions of aberrations among cells, cell survival and transmission of aberrations were investigated. Considering both daughter cells, we found that 20% of fragments and 55% of dicentrics or ring chromosomes are lost during the 1st cell division; i.e. cell survival rate from 1st to 2nd generation is mainly influenced by anaphase bridging of these two-hit aberrations. Cell survival to 2nd mitosis was calculated considering this situation and compared with the survival derived from the fraction of M1 cells without unstable aberrations. The resulting shouldered survival curves showed significantly different slopes, indicating that cell reproductive death is overestimated in the latter approach. (orig.)

  5. Brown's TRANSPORT up to third order aberration by artificial intelligence

    International Nuclear Information System (INIS)

    Xia Jiawen; Xie Xi; Qiao Qingwen

    1991-01-01

    Brown's TRANSPORT is a first and second order matrix multiplication computer program intended for the design of accelerator beam transport systems, neglecting the third order aberration. Recently a new method was developed to derive analytically any order aberration coefficients of general charged particle optic system, applicable to any practical systems, such as accelerators, electron microscopes, lithographs, etc., including those unknown systems yet to be invented. An artificial intelligence program in Turbo Prolog was implemented on IBM-PC 286 or 386 machine to generate automatically the analytical expression of any order aberration coefficients of general charged particle optic system. Based on this new method and technique, Brown's TRANSPORT is extended beyond the second order aberration effects by artificial intelligence, outputing automatically all the analytical expressions up to the third order aberration coefficients

  6. Brown's transport up to third order aberration by artificial intelligence

    International Nuclear Information System (INIS)

    Xia Jiawen; Xie Xi; Qiao Qingwen

    1992-01-01

    Brown's TRANSPORT is a first and second order matrix multiplication computer program intended for the design of accelerator beam transport systems, neglecting the third order aberration. Recently a new method was developed to derive analytically any order aberration coefficients of general charged particle optic system, applicable to any practical systems, such as accelerators, electron microscopes, lithographs, including those unknown systems yet to be invented. An artificial intelligence program in Turbo Prolog was implemented on IBM-PC 286 or 386 machine to generate automatically the analytical expression of any order aberration coefficients of general charged particle optic system. Based on this new method and technique, Brown's TRANSPORT is extended beyond the second order aberration effect by artificial intelligence, outputting automatically all the analytical expressions up to the third order aberration coefficients

  7. Prospects for electron beam aberration correction using sculpted phase masks

    Energy Technology Data Exchange (ETDEWEB)

    Shiloh, Roy, E-mail: royshilo@post.tau.ac.il; Remez, Roei; Arie, Ady

    2016-04-15

    Technological advances in fabrication methods allowed the microscopy community to take incremental steps towards perfecting the electron microscope, and magnetic lens design in particular. Still, state of the art aberration-corrected microscopes are yet 20–30 times shy of the theoretical electron diffraction limit. Moreover, these microscopes consume significant physical space and are very expensive. Here, we show how a thin, sculpted membrane is used as a phase-mask to induce specific aberrations into an electron beam probe in a standard high resolution TEM. In particular, we experimentally demonstrate beam splitting, two-fold astigmatism, three-fold astigmatism, and spherical aberration. - Highlights: • Thin membranes can be used as aberration correctors in electron columns. • We demonstrate tilt, twofold-, threefold-astigmatism, and spherical aberrations. • Experimental and physical-optics simulation results are in good agreement. • Advantages in cost, size, nonmagnetism, and nearly-arbitrary correction.

  8. Aberration-corrected STEM: current performance and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Nellist, P D [Department of Physics, University of Dublin, Trinity College, Dublin 2 (Ireland); Chisholm, M F [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Lupini, A R [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Borisevich, A [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Jr, W H Sides [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Pennycook, S J [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Dellby, N [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Keyse, R [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Krivanek, O L [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Murfitt, M F [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Szilagyi, Z S [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States)

    2006-02-22

    Through the correction of spherical aberration in the scanning transmission electron microscope (STEM), the resolving of a 78 pm atomic column spacing has been demonstrated along with information transfer to 61 pm. The achievement of this resolution required careful control of microscope instabilities, parasitic aberrations and the compensation of uncorrected, higher order aberrations. Many of these issues are improved in a next generation STEM fitted with a new design of aberration corrector, and an initial result demonstrating aberration correction to a convergence semi-angle of 40 mrad is shown. The improved spatial resolution and beam convergence allowed for by such correction has implications for the way in which experiments are performed and how STEM data should be interpreted.

  9. Implication of the presence of a variant hepatic artery during the Whipple procedure

    Directory of Open Access Journals (Sweden)

    Mercedes Rubio-Manzanares-Dorado

    2015-07-01

    Full Text Available Introduction: The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD in patients with or without a variant hepatic artery arising from superior mesenteric artery. Material and methods: We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean ± standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. Results: We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%. The most frequent variant was an aberrant right hepatic artery (n = 7, following by the accessory right hepatic artery (n = 2 and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2. In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Conclusion: Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  10. Wave aberrations in rhesus monkeys with vision-induced ametropias

    Science.gov (United States)

    Ramamirtham, Ramkumar; Kee, Chea-su; Hung, Li-Fang; Qiao-Grider, Ying; Huang, Juan; Roorda, Austin; Smith, Earl L.

    2007-01-01

    The purpose of this study was to investigate the relationship between refractive errors and high-order aberrations in infant rhesus monkeys. Specifically, we compared the monochromatic wave aberrations measured with a Shack-Hartman wavefront sensor between normal monkeys and monkeys with vision-induced refractive errors. Shortly after birth, both normal monkeys and treated monkeys reared with optically induced defocus or form deprivation showed a decrease in the magnitude of high-order aberrations with age. However, the decrease in aberrations was typically smaller in the treated animals. Thus, at the end of the lens-rearing period, higher than normal amounts of aberrations were observed in treated eyes, both hyperopic and myopic eyes and treated eyes that developed astigmatism, but not spherical ametropias. The total RMS wavefront error increased with the degree of spherical refractive error, but was not correlated with the degree of astigmatism. Both myopic and hyperopic treated eyes showed elevated amounts of coma and trefoil and the degree of trefoil increased with the degree of spherical ametropia. Myopic eyes also exhibited a much higher prevalence of positive spherical aberration than normal or treated hyperopic eyes. Following the onset of unrestricted vision, the amount of high-order aberrations decreased in the treated monkeys that also recovered from the experimentally induced refractive errors. Our results demonstrate that high-order aberrations are influenced by visual experience in young primates and that the increase in high-order aberrations in our treated monkeys appears to be an optical byproduct of the vision-induced alterations in ocular growth that underlie changes in refractive error. The results from our study suggest that the higher amounts of wave aberrations observed in ametropic humans are likely to be a consequence, rather than a cause, of abnormal refractive development. PMID:17825347

  11. Aberration-free intraocular lenses - What does this really mean?

    Science.gov (United States)

    Langenbucher, Achim; Schröder, Simon; Cayless, Alan; Eppig, Timo

    2017-09-01

    So-called aberration-free intraocular lenses (IOLs) are well established in modern cataract surgery. Usually, they are designed to perfectly refract a collimated light beam onto the focal point. We show how much aberration can be expected with such an IOL in a convergent light beam such as that found anterior to the human cornea. Additionally, the aberration in a collimated beam is estimated for an IOL that has no aberrations in the convergent beam. The convergent beam is modelled as the pencil of rays corresponding to the spherical wavefront resulting from a typical corneal power of 43m -1 . The IOLs are modelled as infinitely thin phase plates with 20m -1 optical power placed 5mm behind the cornea. Their aberrations are reported in terms of optical path length difference and longitudinal spherical aberration (LSA) of the marginal rays, as well as nominal spherical aberration (SA) calculated based on a Zernike representation of the wavefront-error at the corneal plane within a 6mm aperture. The IOL designed to have no aberrations in a collimated light beam has an optical path length difference of -1.8μm, and LSA of 0.15m -1 in the convergent beam of a typical eye. The corresponding nominal SA is 0.065μm. The IOL designed to have no aberrations in a convergent light beam has an optical path length difference of 1.8μm, and LSA of -0.15m -1 in the collimated beam. An IOL designed to have no aberrations in a collimated light beam will increase the SA of a patient's eye after implantation. Copyright © 2017. Published by Elsevier GmbH.

  12. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  13. Higher-Order Wavefront Aberrations for Populations of Young Emmetropes and Myopes

    Directory of Open Access Journals (Sweden)

    Jinhua Bao

    2009-01-01

    Conclusions: Human eyes have systematical higher order aberrations in population, and factors that cause bilateral symmetry of wavefront aberrations between the right and left eyes made important contribution to the systematical aberrations.

  14. The Mechanisms of Aberrant Protein Aggregation

    Science.gov (United States)

    Cohen, Samuel; Vendruscolo, Michele; Dobson, Chris; Knowles, Tuomas

    2012-02-01

    We discuss the development of a kinetic theory for understanding the aberrant loss of solubility of proteins. The failure to maintain protein solubility results often in the assembly of organized linear structures, commonly known as amyloid fibrils, the formation of which is associated with over 50 clinical disorders including Alzheimer's and Parkinson's diseases. A true microscopic understanding of the mechanisms that drive these aggregation processes has proved difficult to achieve. To address this challenge, we apply the methodologies of chemical kinetics to the biomolecular self-assembly pathways related to protein aggregation. We discuss the relevant master equation and analytical approaches to studying it. In particular, we derive the underlying rate laws in closed-form using a self-consistent solution scheme; the solutions that we obtain reveal scaling behaviors that are very generally present in systems of growing linear aggregates, and, moreover, provide a general route through which to relate experimental measurements to mechanistic information. We conclude by outlining a study of the aggregation of the Alzheimer's amyloid-beta peptide. The study identifies the dominant microscopic mechanism of aggregation and reveals previously unidentified therapeutic strategies.

  15. Absence of orthotopic renal vein with aberrant suprarenal venous drainage; A case report

    International Nuclear Information System (INIS)

    Kim, Eu gene; Jeon, Yong Sun; Cho, Soon Gu; Hong, Kee Chun; Park, Keun Myung; Lee, Tack

    2015-01-01

    A CT scan of a 49-year-old female incidentally revealed a tortuous vascular structure in the right suprarenal space. According to angiographic evaluation of the right renal vessels, the right renal artery was single with normal diameter, and there was no venous drainage through the main right renal vein (orthotopic renal vein). The venous drainage of the right kidney flowed through the tortuous suprarenal vascular structure into the inferior vena cava. The color Doppler ultrasound revealed the monophasic waveform in that vascular structure without flow disturbance. The renal function and the result of urinalysis of the patient were normal, and any other congenital malformation was not found. Absence of the orthotopic renal vein and aberrant suprarenal venous drainage is a very rare congenital anomaly, and it should be discriminated from the other pathologic conditions

  16. Absence of orthotopic renal vein with aberrant suprarenal venous drainage; A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eu gene; Jeon, Yong Sun; Cho, Soon Gu; Hong, Kee Chun; Park, Keun Myung; Lee, Tack [Inha University Hospital, Incheon (Korea, Republic of)

    2015-06-15

    A CT scan of a 49-year-old female incidentally revealed a tortuous vascular structure in the right suprarenal space. According to angiographic evaluation of the right renal vessels, the right renal artery was single with normal diameter, and there was no venous drainage through the main right renal vein (orthotopic renal vein). The venous drainage of the right kidney flowed through the tortuous suprarenal vascular structure into the inferior vena cava. The color Doppler ultrasound revealed the monophasic waveform in that vascular structure without flow disturbance. The renal function and the result of urinalysis of the patient were normal, and any other congenital malformation was not found. Absence of the orthotopic renal vein and aberrant suprarenal venous drainage is a very rare congenital anomaly, and it should be discriminated from the other pathologic conditions.

  17. Arterial tortuosity syndrome: An extremely rare disease presenting as a mimic of pulmonary sling

    Directory of Open Access Journals (Sweden)

    Amy Farkas, MD

    2018-02-01

    Full Text Available Pulmonary sling is the anatomic variant defined by the aberrant origin of the left pulmonary artery from the right pulmonary artery. This patient presented with a mimic of pulmonary sling as a result of an extremely rare condition, arterial tortuosity syndrome (ATS. The patient was first diagnosed with pulmonary sling on prenatal echocardiogram performed by cardiology. Computed tomography angiography of the chest obtained at birth to evaluate respiratory depression demonstrated ATS. The early detection of ATS has been demonstrated to improve patient outcome. This case provides an overview of the typical imaging features of ATS to aid radiologists in making this uncommon diagnosis.

  18. Cellular origin of prognostic chromosomal aberrations in AML patients

    DEFF Research Database (Denmark)

    Mora-Jensen, H.; Jendholm, J.; Rapin, N.

    2015-01-01

    chromosomal structural rearrangements and single nucleotide variants (SNVs). Conventional AML diagnostics and recent seminal next-generation sequencing (NGS) studies have identified more than 200 recurrent genetic aberrations presenting in various combinations in individual patients. Significantly, many...... of these aberrations occur in normal hematopoietic stem and progenitor cells (HSCs/HPCs) before definitive leukemic transformation through additional acquisition of a few (that is, mostly 1 or 2) leukemia-promoting driver aberrations. NGS studies on sorted bone marrow (BM) populations of AML patients with a normal...

  19. Chromosome aberrations analysis of Serbia population from 1985 to 1995

    International Nuclear Information System (INIS)

    Jovicic, D.; Markovic, B.; Milacic, S.; Joksic, G.

    1996-01-01

    After the accident of NE Chernobyl in May 1986, Chernobyl's fallout with unhomogeneous dispersion of radioactive material in atmosphere caused the difference in contamination of the Serbia territory. The highest contamination was found to be in region Uzice, and the lowest in the region Nis. Two groups of population from these regions were undergone chromosome aberration analysis during 1987, 1988 and 1989. year. The results of our examination show increased frequency of structural chromosome aberrations/dicentrics, rings, peri centric inversions and acentric/ in the Uzice population, especially in the 1987. year. In 1985 and 1995 year have not been found chromosome aberrations. 2 refs.; 1 figs.; 2 tabs

  20. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  1. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  2. Chromosome aberration studies and microdosimetry with radiations of varying quality

    International Nuclear Information System (INIS)

    Grillmaier, R.E.; Bihy, L.; Menzel, H.G.; Schuhmacher, H.

    1978-01-01

    To investigate the biological effectivity of complex irradiation fields encountered in radiation protection and high LET radiation therapy and to find meaningful specification of radiation quality closely related to the biological effectivity, correlated chromosome aberration studies and microdosimetric investigations have been carried out using cyclotron produced collimated fast neutrons. Human lymphocytes have been irradiated at different dose levels in the direct beam and in different positions in the penumbra and the rates of acentric fragments and dicentrics have been determined. In identical positions microdosimetric measurements have been performed. The dose relationship of aberration rates after irradiation in the direct beam, the aberration rates observed in the penumbra and the microdosimetric quantities ysub(D), ysub(F) and y* are presented and their relations are discussed. Furthermore the dose relationship of chromosome aberrations induced by 60 Co-γ-rays has been investigated and used to establish the RBE dose relationship of cyclotron neutrons

  3. Chromosome aberrations in pesticide-exposed greenhouse workers

    DEFF Research Database (Denmark)

    Lander, B F; Knudsen, Lisbeth E.; Gamborg, M O

    2000-01-01

    OBJECTIVES: The aim of this study was to investigate the possibility of subtoxic exposure to pesticides causing chromosome aberrations in greenhouse workers. METHODS: In a cross-sectional and prospective study design chromosome aberration frequencies in cultured lymphocytes were examined for 116...... greenhouse workers exposed to a complex mixture of almost 50 insecticides, fungicides, and growth regulators and also for 29 nonsmoking, nonpesticide-exposed referents. RESULTS: The preseason frequencies of chromosome aberrations were slightly but not statistically significantly elevated for the greenhouse...... workers when they were compared with the referents. After a summer season of pesticide spraying in the greenhouses, the total frequencies of cells with chromosome aberrations were significantly higher than in the preseason samples (P=0.02) and also higher than for the referents (P=0.05). This finding...

  4. Brillouin micro-spectroscopy through aberrations via sensorless adaptive optics

    Science.gov (United States)

    Edrei, Eitan; Scarcelli, Giuliano

    2018-04-01

    Brillouin spectroscopy is a powerful optical technique for non-contact viscoelastic characterizations which has recently found applications in three-dimensional mapping of biological samples. Brillouin spectroscopy performances are rapidly degraded by optical aberrations and have therefore been limited to homogenous transparent samples. In this work, we developed an adaptive optics (AO) configuration designed for Brillouin scattering spectroscopy to engineer the incident wavefront and correct for aberrations. Our configuration does not require direct wavefront sensing and the injection of a "guide-star"; hence, it can be implemented without the need for sample pre-treatment. We used our AO-Brillouin spectrometer in aberrated phantoms and biological samples and obtained improved precision and resolution of Brillouin spectral analysis; we demonstrated 2.5-fold enhancement in Brillouin signal strength and 1.4-fold improvement in axial resolution because of the correction of optical aberrations.

  5. Aberrant Chromatin Modification as a Mechanism of Prostate Cancer Progression

    National Research Council Canada - National Science Library

    Chen, Hongwu

    2004-01-01

    .... However, the underlying mechanism is still unclear. The purpose of this study is to test the hypothesis that aberrant chromatin modification plays a critical role in prostate cancer progression...

  6. Establishing working standards of chromosome aberrations analysis for biological dosimetry

    International Nuclear Information System (INIS)

    Bui Thi Kim Luyen; Tran Que; Pham Ngoc Duy; Nguyen Thi Kim Anh; Ha Thi Ngoc Lien

    2015-01-01

    Biological dosimetry is an dose assessment method using specify bio markers of radiation. IAEA (International Atomic Energy Agency) and ISO (International Organization for Standardization) defined that dicentric chromosome is specify for radiation, it is a gold standard for biodosimetry. Along with the documents published by IAEA, WHO, ISO and OECD, our results of study on the chromosome aberrations induced by radiation were organized systematically in nine standards that dealing with chromosome aberration test and micronucleus test in human peripheral blood lymphocytes in vitro. This standard addresses: the reference dose-effect for dose estimation, the minimum detection levels, cell culture, slide preparation, scoring procedure for chromosome aberrations use for biodosimetry, the criteria for converting aberration frequency into absorbed dose, reporting of results. Following these standards, the automatic analysis devices were calibrated for improving biological dosimetry method. This standard will be used to acquire and maintain accreditation of the Biological Dosimetry laboratory in Nuclear Research Institute. (author)

  7. Low level dose induced chromosome aberrations in human blood lymphocytes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Unstable structural aberrations in chromosomes of human blood lymphocytes cannot be used as biological dosemeters in the low dose range, when extrapolating from high doses using a linear dose response, as required by the original formula of the dual radiation action theory. A survey is given of experimental dose-response curves of chromosome aberrations, obtained in investigations not only by this institute, in cooperation with many other laboratories, but also by various authors in different areas of the world. The results are not compatible with the predicted linear dose relationships at in vivo dose ranges up to 30 mGy.y -1 . The aberration frequencies rise sharply with dose within the normal environmental exposure up to about twice that level. At higher doses, aberration frequencies increase less rapidly and reach a plateau. Some in vitro experiments of various authors with higher doses of low LET radiations, up to about 400 mGy have found dose responses with steps. (author)

  8. Electron Optics for Biologists: Physical Origins of Spherical Aberrations

    Science.gov (United States)

    Geissler, Peter; Zadunaisky, Jose

    1974-01-01

    Reports on the physical origins of spherical aberrations in axially symmetric electrostatic lenses to convey the essentials of electon optics to those who must think critically about the resolution of the electron microscope. (GS)

  9. Implantation port-catheter permanent indwelling of pulmonary artery in treating lung metastasis from HCC

    International Nuclear Information System (INIS)

    Cheng Jiemin; Wang Jianhua; Yan Zhiping; Wang Xiaolin; Gong Gaoquan; Liu Qingxin

    2000-01-01

    Objective: To observe the efficacy of a percutaneous implantation port-catheter permanent indwelling pulmonary artery for regional chemotherapy of the metastatic lung cancer from HCC. Methods: Between 1995 and 1999, 62 patients (42 males, 20 females; mean age 46 years) suffering from the metastatic lung cancer from HCC underwent percutaneous implantation of port-catheter permanent indwelling pulmonary artery using the right subclavian vein. In 19 patients with metastatic tumor located on one side of the lung, an indwelling catheter was placed into the ipsilateral side pulmonary artery. With metastasis of both sides, the catheter was inserted into the main trunk of pulmonary artery. The regimens of the chemotherapy were 5-FU + CDDP + MMC(FDM) or 5-FU + CDDP + MMC(FDA). Results: The interventional procedure was successfully completed in all 62 cases (100%). The complications occurred in 8% cases, including infections (3.2%), unhealed wound (1.6%) and pneumothorax (3.2%). The treatment effects of 3-months after the procedure were as follows: the obvious decrease of lung tumor size was 35.5%; stable disease (SD) 32.3% and progressive disease (PD) 32.3%. 6 months follow-up: 12 patients were dead (12/62) and the others are still doing well. The response rates were 22.6%, partial response (PR) 32.3%; stable disease (SD) 25.8% and progressive disease (PD) 32.3%. Conclusions: The percutaneous implantation techniques of pulmonary arterial port-catheter could be a good method in the treatment of metastatic lung cancer from HCC because of it is simple, with few complications and positive effect

  10. Zernike phase spatial filter for measuring the aberrations

    OpenAIRE

    Svetlana N. Khonina; Victor V. Kotlyar; Dmitriy V. Kirsh

    2015-01-01

    To measure directly the wavefront aberration coefficients, we propose to use the multi8order diffractive element fitted with the set of Zernike polynomials. Polynomials of lowest degree describe defocusing (ametropy) and astigmatism. Coefficients of highest degree correspond to the spherical aberration of oblique rays that occurs as a consequence of misalignment of the crystalline lens and foveola, as well as deflection at the periphery of the crystalline lens. Mul^order elements allow severa...

  11. Aberrant alternative splicing is another hallmark of cancer.

    Science.gov (United States)

    Ladomery, Michael

    2013-01-01

    The vast majority of human genes are alternatively spliced. Not surprisingly, aberrant alternative splicing is increasingly linked to cancer. Splice isoforms often encode proteins that have distinct and even antagonistic properties. The abnormal expression of splice factors and splice factor kinases in cancer changes the alternative splicing of critically important pre-mRNAs. Aberrant alternative splicing should be added to the growing list of cancer hallmarks.

  12. Aberrant Alternative Splicing Is Another Hallmark of Cancer

    OpenAIRE

    Ladomery, Michael

    2013-01-01

    The vast majority of human genes are alternatively spliced. Not surprisingly, aberrant alternative splicing is increasingly linked to cancer. Splice isoforms often encode proteins that have distinct and even antagonistic properties. The abnormal expression of splice factors and splice factor kinases in cancer changes the alternative splicing of critically important pre-mRNAs. Aberrant alternative splicing should be added to the growing list of cancer hallmarks.

  13. Aberrant Recapitulation of Developmental Program: Novel Target in Scleroderma

    Science.gov (United States)

    2015-12-01

    AWARD NUMBER: W81XWH-12-1-0472 TITLE: “Aberrant Recapitulation of Developmental Program: Novel Target in Scleroderma ” PRINCIPAL INVESTIGATOR...SUBTITLE Aberrant Recapitulation of Developmental Program: Novel Target in Scleroderma 5a. CONTRACT NUMBER W81XWH-12-1-0472 5b. GRANT NUMBER 5c. PROGRAM...SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT 13. SUPPLEMENTARY NOTES 14. ABSTRACT Fibrosis in scleroderma is associated

  14. Dimensions of driving anger and their relationships with aberrant driving.

    Science.gov (United States)

    Zhang, Tingru; Chan, Alan H S; Zhang, Wei

    2015-08-01

    The purpose of this study was to investigate the relationship between driving anger and aberrant driving behaviours. An internet-based questionnaire survey was administered to a sample of Chinese drivers, with driving anger measured by a 14-item short Driving Anger Scale (DAS) and the aberrant driving behaviours measured by a 23-item Driver Behaviour Questionnaire (DBQ). The results of Confirmatory Factor Analysis demonstrated that the three-factor model (hostile gesture, arrival-blocking and safety-blocking) of the DAS fitted the driving anger data well. The Exploratory Factor Analysis on DBQ data differentiated four types of aberrant driving, viz. emotional violation, error, deliberate violation and maintaining progress violation. For the anger-aberration relation, it was found that only "arrival-blocking" anger was a significant positive predictor for all four types of aberrant driving behaviours. The "safety-blocking" anger revealed a negative impact on deliberate violations, a finding different from previously established positive anger-aberration relation. These results suggest that drivers with different patterns of driving anger would show different behavioural tendencies and as a result intervention strategies may be differentially effective for drivers of different profiles. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  16. Ectopic mineralization disorders of the extracellular matrix of connective tissue: molecular genetics and pathomechanisms of aberrant calcification.

    Science.gov (United States)

    Li, Qiaoli; Jiang, Qiujie; Uitto, Jouni

    2014-01-01

    Ectopic mineralization of connective tissues is a complex process leading to deposition of calcium phosphate complexes in the extracellular matrix, particularly affecting the skin and the arterial blood vessels and common in age-associated disorders. A number of initiating and contributing metabolic and environmental factors are linked to aberrant mineralization in these diseases, making the identification of precise pathomechanistic pathways exceedingly difficult. However, there has been significant recent progress in understanding the ectopic mineralization processes through study of heritable single-gene disorders, which have allowed identification of discrete pathways and contributing factors leading to aberrant connective tissue mineralization. These studies have provided support for the concept of an intricate mineralization/anti-mineralization network present in peripheral connective tissues, providing a perspective to development of pharmacologic approaches to limit the phenotypic consequences of ectopic mineralization. This overview summarizes the current knowledge of ectopic heritable mineralization disorders, with accompanying animal models, focusing on pseudoxanthoma elasticum and generalized arterial calcification of infancy, two autosomal recessive diseases manifesting with extensive connective tissue mineralization in the skin and the cardiovascular system. © 2013.

  17. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    Science.gov (United States)

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  18. Induction of chromosomal aberrations in human lymphocytes by fission neutrons

    International Nuclear Information System (INIS)

    Silva, Marcia Augusta da; Coelho, Paulo Rogerio Pinto; Bartolini, Paolo; Okazaki, Kayo

    2009-01-01

    Chromosome aberrations induced by sparsely ionizing radiation (low-LET) are well known and cytogenetic analyses of irradiated human lymphocytes have been widely applied to biological dosimetry. However, much less is known about chromosome aberrations induced by densely ionizing radiation (high LET), such as that of alpha particles or neutrons. Such particles induce DNA strand breaks, as well as chromosome breakage and rearrangements of high complexity. This damage is more localized and less efficiently repaired than after X- or γ-ray irradiation. This preferential production of complex aberrations by densely ionizing radiation is related to the unique energy deposition patterns, which produces highly localized multiple DNA damage at the chromosomal level. A better knowledge of the interactions between different types of radiation and cellular DNA is of importance, not only from the radiobiological viewpoint but also for dosimetric and therapeutic purposes. The objective of the present study was to analyse the cytogenetic effects of fission neutrons on peripheral blood lymphocytes in order to evaluate structural and numerical aberrations and number of cells in the different mitotic cycles. So, blood samples from five healthy donors, 22-25 years old, of both sexes, were irradiated in the Research Reactor IEA-R1 of our Institute (IPEN/CNEN-SP) with thermal and fast neutrons at doses of 0.2; 0.3; 0.5 and 1.0 Gy. The γ contribution to the total absorbed dose was about 30%. These doses were monitored by thermoluminescent dosemeters: LiF-600 (for neutrons) and LiF-700 (for γ-rays). The data concerning structural aberrations were evaluated with regard to three parameters: percentage of cells with aberrations, number of aberrations/cell and number of dicentric/cell. The cytogenetic results showed an increase in the three parameters after irradiation with neutrons, as a function of radiation dose. Apparently, there was no influence of neutrons on the kinetics of cellular

  19. Large mobile thrombus in non-atherosclerotic thoracic aorta as the source of peripheral arterial embolism

    Directory of Open Access Journals (Sweden)

    Brkovic Zoran

    2005-11-01

    Full Text Available Abstract The presence of thrombi in the atherosclerotic and/or aneurysmatic aorta with peripheral arterial embolism is a common scenario. Thrombus formation in a morphologically normal aorta, however, is a rare event. A 50 years old woman was admitted to the mergency department for pain, coldness, and anesthesia in the the left foot. She had a 25 years history of cigarette smoking, a history of postmenopausal hormone replacement therapy (HRT, hypercholesterolemia and hyperfibrinogenemia. An extensive serologic survey for hypercoagulability, including antiphospholipid antibodies, and vasculitis disorders was negative. Transesophageal echocardiography revealed a large, pedunculated and hypermobile thrombus attached to the aortic wall 5 cm distal of the left subclavian artery. The patient was admitted to the surgery department, where a 15 cm long fresh, parietal thrombus could be removed from the aorta showing no macroscopic wall lesions or any other morphologic abnormalities. This case report demonstrates the possibility of evolving a large, pedunculated thrombus in a morphologically intact aorta in a postmenopausal woman with thrombogenic conditions such as hyperfibrinogenemia, hypercholesterolemia, smoking and HRT. For these patients, profiling the individual risk and weighing the benefits against the potential risks is warranted before prescribing HRT.

  20. Ionizing radiation and frequency of chromosomal aberrations in exposed personnel

    International Nuclear Information System (INIS)

    Spasojevic-Tisma, Vera; Pavlovic, Snezana

    2008-01-01

    Full text: Frequencies of chromosomal aberrations in lymphocytes of peripheral blood were investigated among the observed groups of subjects who were exposed to low radiation doses (external exposure) in comparison with the control group. The first group of subjects is involved in the production of radioisotope technetium, whose accumulated work exposure time ranges between 3 and 30 years. The second group works on inspection of the medical X-ray equipment, whose accumulated work exposure time is between 2 and 34 years. The third group worked on decontamination of the terrain from depleted uranium radioactive ammunition. These workers were involved in mechanical removal of the surface soil layer to a depth of 50 cm. They were selected out of a group of professionals otherwise exposed to radiation from confined sources in their daily work. The accumulated work exposure of this group ranged from 2 to 34 years. The control group consisted of individuals not working in the ionizing radiation zone. The average yearly absorbed dose measured by TL dosimeters for all three observed groups did not exceed 2 mSv. The chromosomal aberrations were analyzed by a modified Moorhead method. The objective of the study was to establish the existence of differences in the frequencies of chromosomal aberrations change with respect to the source type, i.e. type of radioactive emission. Comparisons of the chromosomal changes in the observed groups revealed that the group working on technetium production had an increase in the frequency of chromosomal aberrations with respect to control. The aberrations found were of the acentric fragment and chromosomal break types. A comparison of the exposed groups between each other, no statistically significant differences in the numbers of chromosomal aberrations were found. Soil decontamination from depleted uranium did not contribute to the relative radiation risk, since it lasted only a few months, and was done by the professionals fully clothed

  1. Revisiting Cross-Channel Information Transfer for Chromatic Aberration Correction

    KAUST Repository

    Sun, Tiancheng; Peng, Yifan; Heidrich, Wolfgang

    2017-01-01

    Image aberrations can cause severe degradation in image quality for consumer-level cameras, especially under the current tendency to reduce the complexity of lens designs in order to shrink the overall size of modules. In simplified optical designs, chromatic aberration can be one of the most significant causes for degraded image quality, and it can be quite difficult to remove in post-processing, since it results in strong blurs in at least some of the color channels. In this work, we revisit the pixel-wise similarity between different color channels of the image and accordingly propose a novel algorithm for correcting chromatic aberration based on this cross-channel correlation. In contrast to recent weak prior-based models, ours uses strong pixel-wise fitting and transfer, which lead to significant quality improvements for large chromatic aberrations. Experimental results on both synthetic and real world images captured by different optical systems demonstrate that the chromatic aberration can be significantly reduced using our approach.

  2. Radiation-induced cellular reproductive death and chromosome aberrations

    International Nuclear Information System (INIS)

    Bedford, J.S.; Mitchell, J.B.; Griggs, H.G.; Bender, M.A.

    1978-01-01

    If a major mode of cell killing by ionizing radiation is the death of cells containing visible chromosomal aberrations, as for example from anaphase-bridge formation at mitosis, then cells bearing such aberrations should be selectively eliminated from the population, resulting in an increased survival potential for the population remaining at each succeeding cell generation. Using synchronized V79B Chinese hamster cells, we measured the aberration frequency and the colony-forming ability of mitotic cells at each of the first three generations following irradiation in G1. Cells were resynchronized by mechanial harvest at each succeeding mitosis after irradiation in order to avoid mixing of generations in the cell population at later sampling times. As anticipated, the chromosome aberration frequencies decreased markedly from the first to the second and from the second to the third mitosis. The surviving fraction, however, was virtually the same for plating assays carried out immediately after irradiation, at the first, or at the second mitosis. The surviving fraction was significantly higher for cells reaching the third postirradiation mitosis. Survival and aberration frequencies were assayed again at approximately the fourteenth postirradiation division, by which time the irradiated and control populations were not significantly different

  3. Primary chromatic aberration elimination via optimization work with genetic algorithm

    Science.gov (United States)

    Wu, Bo-Wen; Liu, Tung-Kuan; Fang, Yi-Chin; Chou, Jyh-Horng; Tsai, Hsien-Lin; Chang, En-Hao

    2008-09-01

    Chromatic Aberration plays a part in modern optical systems, especially in digitalized and smart optical systems. Much effort has been devoted to eliminating specific chromatic aberration in order to match the demand for advanced digitalized optical products. Basically, the elimination of axial chromatic and lateral color aberration of an optical lens and system depends on the selection of optical glass. According to reports from glass companies all over the world, the number of various newly developed optical glasses in the market exceeds three hundred. However, due to the complexity of a practical optical system, optical designers have so far had difficulty in finding the right solution to eliminate small axial and lateral chromatic aberration except by the Damped Least Squares (DLS) method, which is limited in so far as the DLS method has not yet managed to find a better optical system configuration. In the present research, genetic algorithms are used to replace traditional DLS so as to eliminate axial and lateral chromatic, by combining the theories of geometric optics in Tessar type lenses and a technique involving Binary/Real Encoding, Multiple Dynamic Crossover and Random Gene Mutation to find a much better configuration for optical glasses. By implementing the algorithms outlined in this paper, satisfactory results can be achieved in eliminating axial and lateral color aberration.

  4. Chromosomal aberrations in subjects exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Jovicic, D.; Milacic, S.; Kovacevic, R.; Tanaskovic, I.

    2006-01-01

    Occupational exposure is particularly delicate because of chronic exposure to low doses of ionizing radiation and its cumulative effect, where it is important to consider the biological response of body to given conditions of exposure. The objective of this study was the observation of the recovery of the DNA damages in subjects working in the radiation area in two different intervals.Group I, consisting of 30 subjects, was exposed to ionizing radiation and unstable chromosomal aberrations were identified. Group II included the same, re-examined subjects (30) 9 months later. It was verified that 5 (16.67%) subjects still had unstable chromosomal aberrations, although they had been excluded from radiation area Controls groups (C) consisted of 64 subjects that were not exposed to mutagenic agents.The comparison of the control group with the two studied groups revealed the reduction of the unstable aberrations (p<0.05). The total effective doses, which increased with the years spent in radiation area, reflected the yield of chromosomal aberrations. The presence of chromosomal aberrations in some subjects, after the exclusion from the ionising radiation exposure, suggests that the time needed for the recovery of the DNA damages is different, which indicates the individual differences in radiosensitivity as well as different of the reparatory cellular response. (author)

  5. Revisiting Cross-Channel Information Transfer for Chromatic Aberration Correction

    KAUST Repository

    Sun, Tiancheng

    2017-12-25

    Image aberrations can cause severe degradation in image quality for consumer-level cameras, especially under the current tendency to reduce the complexity of lens designs in order to shrink the overall size of modules. In simplified optical designs, chromatic aberration can be one of the most significant causes for degraded image quality, and it can be quite difficult to remove in post-processing, since it results in strong blurs in at least some of the color channels. In this work, we revisit the pixel-wise similarity between different color channels of the image and accordingly propose a novel algorithm for correcting chromatic aberration based on this cross-channel correlation. In contrast to recent weak prior-based models, ours uses strong pixel-wise fitting and transfer, which lead to significant quality improvements for large chromatic aberrations. Experimental results on both synthetic and real world images captured by different optical systems demonstrate that the chromatic aberration can be significantly reduced using our approach.

  6. Results of Surgical Treatment of Patients with Critical Limb Ischemia and Stenotic Lesions of the Brachiocephalic Arteries

    Directory of Open Access Journals (Sweden)

    Alexei L. Charyshkin

    2017-06-01

    Full Text Available The aim of our study was to evaluate the results of the surgical treatment for patients with critical limb ischemia (CLI and stenotic lesions of the brachiocephalic arteries. Methods and Results: We examined 72 patients (68/87.2% men and 4/7.3% women aged from 46 to 78 years (mean age, 62.2±4.3 years with CLI and stenotic lesions of the brachiocephalic arteries. Conservative treatment was performed in 17(23.6% patients and surgical treatment in 55(76.4%. It has been carried out 73 surgical operations: femoral popliteal bypass (5/6.8%, lumbar sympathectomy (4/5.5%, thrombectomy of occluded aortofemoral graft (2/2.7%, limb amputation (4/5.5%, iliofemoral bypass (4/5.5%, aortofemoral bifurcation bypass (10/13.1%, endovascular surgery (1/1.6%, limb amputation at thigh level - 4(5.5%, thrombectomy of occluded distal arteries (4/5.5%, femoro-femoral cross-over bypass (1/1.6%, resection of popliteal artery aneurysm and prosthesis of the popliteal artery (1/1.6%, semi-closed loop endarterectomy of occluded arteries of the lower limbs (8/10.9%, carotid endarterectomy (23/31.5%, and carotid-subclavian bypass (2/2.7%. After the surgical intervention, we observed the disappearance or reduction of pain, restoration of sensitivity and motor activity, and healing of trophic ulcers in 75% of patients. In the late postoperative period, we detected the progression of limb ischemia in 4(5.5% patients; in connection with that, we performed limb amputation at thigh level. Ischemic stroke with a lethal outcome developed in one patient (1.4%. Conclusion: In patients with multifocal atherosclerosis, multilevel reconstructive surgical interventions must be performed in stages, due to the high operational risk, and risk of complications, secondary amputations and lethality in the postoperative period.

  7. Spherical aberration and other higher-order aberrations in the human eye : from summary wave-front analysis data to optical variables relevant to visual perception

    NARCIS (Netherlands)

    Jansonius, Nomdo M.

    Wave-front analysis data from the human eye are commonly presented using the aberration coefficient c(4)(0) (primary spherical aberration) together with an overall measure of all higher-order aberrations. If groups of subjects are compared, however, the relevance of an observed difference cannot

  8. Duplicated middle cerebral artery

    Science.gov (United States)

    Perez, Jesus; Machado, Calixto; Scherle, Claudio; Hierro, Daniel

    2009-01-01

    Duplicated middle cerebral artery (DMCA) is an anomalous vessel arising from the internal carotid artery. The incidence DMCA is relatively law, and an association between this anomaly and cerebral aneurysms has been documented. There is a controversy whether DMCA may have perforating arteries. This is an important fact to consider in aneurysm surgery. We report the case of a 34-year-old black woman who suffered a subarachnoid hemorrhage and the angiography a left DMCA, and an aneurysm in an inferior branch of the main MCA. The DMCA and the MCA had perforating arteries. The aneurysm was clipped without complications. The observation of perforating arteries in our patient confirms that the DMCA may have perforating arteries. This is very important to be considered in cerebral aneurysms surgery. Moreover, the DMCA may potentially serve as a collateral blood supply to the MCA territory in cases of MCA occlusion. PMID:22140405

  9. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  10. Variability of the vertebral artery origin and transverse foramen entrance level - CT angiographic study.

    Science.gov (United States)

    Vujmilović, Siniša; Spasojević, Goran; Vujnović, Saša; Malobabić, Slobodan; Vujković, Zoran

    2018-04-13

    Vertebral artery (VA), the main element of the posterior brain circulation, has many anatomical variations which generally were widely investigated. However, available data vary in wide ranges, reflecting very different sample sizes, lack of data about left-right or sex differences, and about possible ethnic, regionally specific or genetic differences. Certain new findings suggest possible involvement of some environmental factors in VA variations. Accurate anatomical data about VA variations in different regions of the world, including Balkans countries, are still lacking. Therefore we investigated morphological variability of VA origin and its entrance level into cervical transverse foramina in population of Republika Srpska (Bosnia and Herzegovina), including data about the sex and side. Anatomy of VA was investigated in 112 persons (224 arteries) of both sexes (58 males, 54 females; age 19 - 83 years), using 64-slice CT scanner. Origin of VA from subclavian artery (SCA) we found in 95.08% of arteries (52 males, 49 females). Only in one male (0.45 %) left VA and left SCA had an specific origin from aortic arch (AA), which we named as an "common area of origin". All other observed variations in origin were only of left VA, originating from AA in 4.47 % (5 males, 5 females). Left VA Most often (usual) entrance level into transverse foramen we found at C6 (87.5%), followed by C5 (8.93 %), C4 (3.12 %), and in one case at level C7 (0.45 %). Entry levels at C5 both, on right and on the left side, were 3 times more frequent in males than in females. Wide ranges of differences between the data we obtained on a sample in Republika Srpska (Bosnia and Herzegovina) and the data from many other studies require further and wider investigations.

  11. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  12. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  13. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  14. Aberrations in preliminary design of ITER divertor impurity influx monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kitazawa, Sin-iti, E-mail: kitazawa.siniti@jaea.go.jp [Naka Fusion Institute, Japan Atomic Energy Agency, JAEA, Naka 311-0193 (Japan); Ogawa, Hiroaki [Naka Fusion Institute, Japan Atomic Energy Agency, JAEA, Naka 311-0193 (Japan); Katsunuma, Atsushi; Kitazawa, Daisuke [Core Technology Center, Nikon Corporation, Yokohama 244-8533 (Japan); Ohmori, Keisuke [Customized Products Business Unit, Nikon Corporation, Mito 310-0843 (Japan)

    2015-12-15

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • The spot diagrams were suppressed within the core of receiving fiber. • The aberration of DIM is suppressed in the preliminary design. - Abstract: Divertor impurity influx monitor for ITER (DIM) is a diagnostic system that observes light from nuclear fusion plasma directly. This system is affected by various aberrations because it observes light from the fan-array chord near the divertor in the ultraviolet–near infrared wavelength range. The aberrations should be suppressed to the extent possible to observe the light with very high spatial resolution. In the preliminary design of DIM, spot diagrams were suppressed within the core of the receiving fiber's cross section, and the resulting spatial resolutions satisfied the design requirements.

  15. Estimation and Compensation of aberrations in Spatial Light Modulators

    International Nuclear Information System (INIS)

    Arias, Augusto; Castaneda, Roman

    2011-01-01

    The spatial light modulator (SLM) Holoeye LC-R720 is based on LCoS (Liquid Crystal on Silicon) technology. Due to the induced curvatures on the silicon plate by the production process, there are static aberrations in the wave-fronts modified by the SLM. In order to calculate the aberrated wave-front we used phase-shifting interferometry, an optimization algorithm for far field propagation, and the geometric characterization of the focal spot along the caustic. Zernike polynomials were used for expanding and comparing the wave-fronts. The aberration compensation was carried out by displaying the conjugated transmittance on the SLM. The complexity of the experimental setup and the requirements of the digital processing of each estimation method were comparatively analyzed.

  16. Screening for aberrant behavior in the nuclear industry

    International Nuclear Information System (INIS)

    Borofsky, G.L.

    1987-01-01

    This paper attempts to promote a fuller understanding of how psychological assessment procedures can be used to reduce the threat from aberrant behavior in the nuclear industry. It begins with a discussion of the scientifically based methods that are used by psychologists in constructing, scoring, and interpreting these procedures. This discussion includes an emphasis on the concepts of validity and reliability and their central importance when one is choosing specific psychological screening tools. Criteria for selecting and using psychological assessment procedures when screening for aberrant behavior are also provided. Some commonly used assessment procedures that satisfy these criteria are discussed. A number a psychological assessment procedures specifically recommended for use in screening for aberrant behavior in the nuclear industry are described

  17. Split-plot fractional designs: Is minimum aberration enough?

    DEFF Research Database (Denmark)

    Kulahci, Murat; Ramirez, Jose; Tobias, Randy

    2006-01-01

    Split-plot experiments are commonly used in industry for product and process improvement. Recent articles on designing split-plot experiments concentrate on minimum aberration as the design criterion. Minimum aberration has been criticized as a design criterion for completely randomized fractional...... factorial design and alternative criteria, such as the maximum number of clear two-factor interactions, are suggested (Wu and Hamada (2000)). The need for alternatives to minimum aberration is even more acute for split-plot designs. In a standard split-plot design, there are several types of two...... for completely randomized designs. Consequently, we provide a modified version of the maximum number of clear two-factor interactions design criterion to be used for split-plot designs....

  18. [Frequency of chromosome aberrations in residents of the Semipalatinsk Oblast].

    Science.gov (United States)

    Gubitskaia, E G; Akhmatullina, N B; Vsevolodov, E B; Bishnevskaia, S S; Sharipov, I K; Cherednichenko, O G

    1999-06-01

    Cytogenetic analysis of the population of the Beskaragai district of the Semipalatinsk oblast adjacent to the territory of the nuclear test site was conducted by means of an ecological genetic questionnaire and cytogenetic examination of metaphase chromosomes. An increase in the total mutation level in the region was observed. The frequency of chromosome aberrations among the population of the Beskaragai district (3.2%) was statistically significantly (about 1.5 times) higher than the background levels in the clear regions (from 1 to 2%). Furthermore, the frequency of aberrations in adolescents was comparable with that in the adults. The spectrum of chromosome aberrations pointed to a significant contribution of radiation component to the mutagenesis.

  19. Low chromatic aberration hexapole for molecular state selection

    International Nuclear Information System (INIS)

    Ke, Yi; Deng, Xiao-Bing; Hu, Zhong-Kun

    2016-01-01

    In molecular beam state-selection experiments, the electrostatic hexapole acts as an optical lens, imaging molecules from the source to the focus. The molecular longitudinal velocity spread induces the phenomenon of chromatic aberration, which will reduce the state-selection purity. We propose a scheme which can effectively reduce the chromatic aberration by changing the hexapole voltage operating manner. The hexapole is already charged before molecules arrive at the entrance of the hexapole. When molecules are completely inside the hexapole, the voltage is switched off rapidly at an appropriate time. In this manner, faster molecules travel a longer hexapole focusing region than slower molecules. Therefore the focusing positions of molecules with different velocities become close. Numerical trajectory simulations of molecular state selection are carried out, and the results show that this low chromatic aberration hexapole can significantly improve the state purity from 46.2% to 87.0%. (paper)

  20. Biological dosimetry: chromosomal aberration analysis for dose assessment

    International Nuclear Information System (INIS)

    1986-01-01

    In view of the growing importance of chromosomal aberration analysis as a biological dosimeter, the present report provides a concise summary of the scientific background of the subject and a comprehensive source of information at the technical level. After a review of the basic principles of radiation dosimetry and radiation biology basic information on the biology of lymphocytes, the structure of chromosomes and the classification of chromosomal aberrations are presented. This is followed by a presentation of techniques for collecting blood, storing, transporting, culturing, making chromosomal preparations and scaring of aberrations. The physical and statistical parameters involved in dose assessment are discussed and examples of actual dose assessments taken from the scientific literature are given

  1. Correcting the Chromatic Aberration in Barrel Distortion of Endoscopic Images

    Directory of Open Access Journals (Sweden)

    Y. M. Harry Ng

    2003-04-01

    Full Text Available Modern endoscopes offer physicians a wide-angle field of view (FOV for minimally invasive therapies. However, the high level of barrel distortion may prevent accurate perception of image. Fortunately, this kind of distortion may be corrected by digital image processing. In this paper we investigate the chromatic aberrations in the barrel distortion of endoscopic images. In the past, chromatic aberration in endoscopes is corrected by achromatic lenses or active lens control. In contrast, we take a computational approach by modifying the concept of image warping and the existing barrel distortion correction algorithm to tackle the chromatic aberration problem. In addition, an error function for the determination of the level of centroid coincidence is proposed. Simulation and experimental results confirm the effectiveness of our method.

  2. An electron microscope for the aberration-corrected era

    Energy Technology Data Exchange (ETDEWEB)

    Krivanek, O.L. [Nion Co., 1102 8th Street, Kirkland, WA 98033 (United States)], E-mail: krivanek.ondrej@gmail.com; Corbin, G.J.; Dellby, N.; Elston, B.F.; Keyse, R.J.; Murfitt, M.F.; Own, C.S.; Szilagyi, Z.S.; Woodruff, J.W. [Nion Co., 1102 8th Street, Kirkland, WA 98033 (United States)

    2008-02-15

    Improved resolution made possible by aberration correction has greatly increased the demands on the performance of all parts of high-end electron microscopes. In order to meet these demands, we have designed and built an entirely new scanning transmission electron microscope (STEM). The microscope includes a flexible illumination system that allows the properties of its probe to be changed on-the-fly, a third-generation aberration corrector which corrects all geometric aberrations up to fifth order, an ultra-responsive yet stable five-axis sample stage, and a flexible configuration of optimized detectors. The microscope features many innovations, such as a modular column assembled from building blocks that can be stacked in almost any order, in situ storage and cleaning facilities for up to five samples, computer-controlled loading of samples into the column, and self-diagnosing electronics. The microscope construction is described, and examples of its capabilities are shown.

  3. An electron microscope for the aberration-corrected era

    International Nuclear Information System (INIS)

    Krivanek, O.L.; Corbin, G.J.; Dellby, N.; Elston, B.F.; Keyse, R.J.; Murfitt, M.F.; Own, C.S.; Szilagyi, Z.S.; Woodruff, J.W.

    2008-01-01

    Improved resolution made possible by aberration correction has greatly increased the demands on the performance of all parts of high-end electron microscopes. In order to meet these demands, we have designed and built an entirely new scanning transmission electron microscope (STEM). The microscope includes a flexible illumination system that allows the properties of its probe to be changed on-the-fly, a third-generation aberration corrector which corrects all geometric aberrations up to fifth order, an ultra-responsive yet stable five-axis sample stage, and a flexible configuration of optimized detectors. The microscope features many innovations, such as a modular column assembled from building blocks that can be stacked in almost any order, in situ storage and cleaning facilities for up to five samples, computer-controlled loading of samples into the column, and self-diagnosing electronics. The microscope construction is described, and examples of its capabilities are shown

  4. Aberrations in preliminary design of ITER divertor impurity influx monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki; Katsunuma, Atsushi; Kitazawa, Daisuke; Ohmori, Keisuke

    2015-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • The spot diagrams were suppressed within the core of receiving fiber. • The aberration of DIM is suppressed in the preliminary design. - Abstract: Divertor impurity influx monitor for ITER (DIM) is a diagnostic system that observes light from nuclear fusion plasma directly. This system is affected by various aberrations because it observes light from the fan-array chord near the divertor in the ultraviolet–near infrared wavelength range. The aberrations should be suppressed to the extent possible to observe the light with very high spatial resolution. In the preliminary design of DIM, spot diagrams were suppressed within the core of the receiving fiber's cross section, and the resulting spatial resolutions satisfied the design requirements.

  5. In vivo chromatic aberration in eyes implanted with intraocular lenses.

    Science.gov (United States)

    Pérez-Merino, Pablo; Dorronsoro, Carlos; Llorente, Lourdes; Durán, Sonia; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2013-04-12

    To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in

  6. In vivo longitudinal chromatic aberration of pseudophakic eyes.

    Science.gov (United States)

    Siedlecki, Damian; Jóźwik, Agnieszka; Zając, Marek; Hill-Bator, Aneta; Turno-Kręcicka, Anna

    2014-02-01

    To present the results of longitudinal chromatic aberration measurements on two groups of pseudophakic eyes in comparison to healthy eyes. The longitudinal chromatic aberration of the eye, defined as chromatic difference of refraction with disabled accommodation, was measured with the use of a visual refractometer with a custom-designed target illuminator consisting of a narrow-band RGB diode (blue λb = 470 ± 15 nm; green λg = 525 ± 18 nm; red λr = 660 ± 10 nm). The measurements were performed on nine eyes implanted with AcrySof IQ SN60WF, 14 eyes implanted with AcrySof SA60AT, and 10 phakic eyes under cycloplegia. The mean values of the longitudinal chromatic aberration between 470 and 660 nm for the control group was 1.12 ± 0.14 D. For SA60AT group, it was 1.45 ± 0.42 D whereas for SN60WF it was 1.17 ± 0.52 D. The statistical test showed significant difference between SA60AT and the control group (p chromatic aberration in vivo can be easily and reliably estimated with an adapted visual refractometer. The two groups of pseudophakic eyes measured in this study showed different values of chromatic aberration. Its magnitude for SA60AT group was significantly larger than for the control group whereas for SN60WF the difference was not significant. The optical material used for intraocular lens design may have significant influence on the magnitude of the chromatic aberration of the pseudophakic eye, and therefore on its optical and visual performance in polychromatic light.

  7. Scaling laws for aberrations in magnetic quadrupole lens systems

    International Nuclear Information System (INIS)

    Moses, R.W.; Heighway, E.A.; Christian, R.S.; Dragt, A.J.

    1987-01-01

    A comparison has been made of the third-order (spherical) abberrations in magnetic quadrupole lenses for use in conventional charged particle beam transport systems. An analytical description of the abberrations is presented and this is compared with the results of high order numerical integration. The dependence of the aberration strength on the system geometry and f number is given and a comparison of doublet and triplet systems made. The reduction of the aberrations in both doublet and triplet systems using embedded magnetic octupole lenses is also discussed and analytical predictions are given

  8. Aberration compensation using a spatial light modulator LCD

    International Nuclear Information System (INIS)

    Amezquita, R; Rincon, O; Torres, Y M

    2011-01-01

    The dynamic correction of aberrations introduced in optical systems have been a widely discussed topic in the past 10 years. Adaptive optics is the most important developed field where the Shack-Hartmann sensors and deformable mirrors are used for the measurement and correction of wavefronts. In this paper, an interferometric set-up which uses a Spatial Light Modulator (SLM) as an active element is proposed. Using this SLM a procedure for the compensation of all phase aberrations present in the experimental setup is shown.

  9. Measurement of eye aberrations in a speckle field

    International Nuclear Information System (INIS)

    Larichev, A V; Ivanov, P V; Iroshnikov, N G; Shmalgauzen, V I

    2001-01-01

    The influence of speckles on the performance of a Shark-Hartmann wavefront sensor is investigated in the eye aberration studies. The dependence of the phase distortion measurement error on the characteristic speckle size is determined experimentally. Scanning of the reference source was used to suppress the speckle structure of the laser beam scattered by the retina. The technique developed by us made it possible to study the time dependence of the human eye aberrations with a resolution of 30 ms. (laser applications and other topics in quantum electronics)

  10. Selective corneal optical aberration (SCOA) for customized ablation

    Science.gov (United States)

    Jean, Benedikt J.; Bende, Thomas

    2001-06-01

    Wavefront analysis still have some technical problems which may be solved within the next years. There are some limitations to use wavefront as a diagnostic tool for customized ablation alone. An ideal combination would be wavefront and topography. Meanwhile Selective Corneal Aberration is a method to visualize the optical quality of a measured corneal surface. It is based on a true measured 3D elevation information of a video topometer. Thus values can be interpreted either using Zernike polynomials or visualized as a so called color coded surface quality map. This map gives a quality factor (corneal aberration) for each measured point of the cornea.

  11. Static telescope aberration measurement using lucky imaging techniques

    Science.gov (United States)

    López-Marrero, Marcos; Rodríguez-Ramos, Luis Fernando; Marichal-Hernández, José Gil; Rodríguez-Ramos, José Manuel

    2012-07-01

    A procedure has been developed to compute static aberrations once the telescope PSF has been measured with the lucky imaging technique, using a nearby star close to the object of interest as the point source to probe the optical system. This PSF is iteratively turned into a phase map at the pupil using the Gerchberg-Saxton algorithm and then converted to the appropriate actuation information for a deformable mirror having low actuator number but large stroke capability. The main advantage of this procedure is related with the capability of correcting static aberration at the specific pointing direction and without the need of a wavefront sensor.

  12. Propagation of highly aberrated laser beams in nonquadratic plasma waveguides

    International Nuclear Information System (INIS)

    Feit, M.D.; Fleck, J.A. Jr.; Morris, J.R.

    1977-01-01

    The propagation of a laser beam in a plasma column several meters long with a realistic electron density distribution is examined. The electron density distribution is based on laser-beam heating at z=0, but is otherwise uncoupled to the laser beam. The aberrated nature of the resulting lenslike medium leads to essentially aperiodic beam properties, which contrast with the completely periodic properties of Gaussian beams propagating in quadratic lenslike media. The beam is nonetheless stably trapped. These aberrated-beam properties also help to stabilize the beam against axial variations in refractive index

  13. Elimination of aberrations in wide-aperture magnetoelectrostatic plasma lenses

    International Nuclear Information System (INIS)

    Butenko, V.I.; Ivanov, B.I.

    2003-01-01

    A computer model is devised for a Morozov plasma lens, in which the magnetic surfaces are equipotential surfaces of the electric field. Results are presented from numerical modeling of the focusing of ions with allowance for their longitudinal, radial, and azimuthal motions. The strengths and spatial distributions of the magnetic and electric fields are optimized. The methods for removing moment, geometric, and chromatic aberrations are analyzed. The effect of a discrete distribution of the potentials on ion focusing is modeled, and the related aberrations are examined. A computer model of an achromatic two-lens system is considered

  14. Papillary carcinoma in median aberrant thyroid (ectopic) - case report.

    Science.gov (United States)

    Hebbar K, Ashwin; K, Shashidhar; Deshmane, Vijaya Laxmi; Kumar, Veerendra; Arjunan, Ravi

    2014-06-01

    Median ectopic thyroid may be encountered anywhere from the foramen caecum to the diaphragm. Non lingual median aberrant thyroid (incomplete descent) usually found in the infrahyoid region and malignant transformation in this ectopic thyroid tissue is very rare. We report an extremely rare case of papillary carcinoma in non lingual median aberrant thyroid in a 25-year-old female. The differentiation between a carcinoma arising in the median ectopic thyroid tissue and a metastatic papillary carcinoma from an occult primary in the main thyroid gland is also discussed.

  15. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  16. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  17. Aberration of a negative ion beam caused by space charge effect.

    Science.gov (United States)

    Miyamoto, K; Wada, S; Hatayama, A

    2010-02-01

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  18. Aberration of a negative ion beam caused by space charge effect

    International Nuclear Information System (INIS)

    Miyamoto, K.; Wada, S.; Hatayama, A.

    2010-01-01

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  19. Aberration of a negative ion beam caused by space charge effect

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Wada, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2010-02-15

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  20. Differential algebraic method for arbitrary order curvilinear-axis combined geometric-chromatic aberration analysis

    International Nuclear Information System (INIS)

    Cheng Min; Tang Tiantong; Lu Yilong; Yao Zhenhua

    2003-01-01

    The principle of differential algebra is applied to analyse and calculate arbitrary order curvilinear-axis combined geometric-chromatic aberrations of electron optical systems. Expressions of differential algebraic form of high order combined aberrations are obtained and arbitrary order combined aberrations can be calculated numerically. As an example, a typical wide electron beam focusing system with curved optical axes named magnetic immersion lens has been studied. All the second-order and third-order combined geometric-chromatic aberrations of the lens have been calculated, and the patterns of the corresponding geometric aberrations and combined aberrations have been given as well

  1. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  2. Occlusion of Heubner's artery

    International Nuclear Information System (INIS)

    Sato, Manabu; Kidooka, Minoru

    1982-01-01

    A case of occlusion of the left Heubner's artery in a right-handed, 51-year-old man is reported. Cardinal clinical features were transient right hemiparesis and mental disturbance, especially intellectual defect. Low density areas were found at CT in the globus pallidus, putamen, anterior limb of the internal capsule and a part of the caudate nucleus. It is well known that the occlusion of the Heubner's artery causes transient motor paresis of upper extremity on the contralaterl side. However, in the case where the Heubner's artery is remarkably well developed when compared with the medial striate arteries as was the case in this patient, it should be noted that the occlusion of the Heubner's artery may well causes grave mental disturbance, in addition. (author)

  3. Novel plumage aberrations in Paraguayan non-Passerine Birds, and the definition of a new plumage aberration unique to Psittacidae

    Directory of Open Access Journals (Sweden)

    Paul Smith

    2017-07-01

    Full Text Available Anomalous plumage colourations are reported for three species of non-passerine birds from Paraguay, Limpkin (Aramaus guarauna; Aramidae, Nanday Parakeet (Nandayus nenday; Psittacidae, and the Little Woodpecker (Veniliornis passerinus; Picidae. A leucistic Limpkin is the first published report of a colour anomaly for the family Aramidae. The colour aberration in N. nenday is hypothesised to be a result of an excess of red psittacofulvin pigments, which are unique to the Psittacidae. Although the mechanisms causing this colour aberration remain unknown, we suggest the term psittacofulvism for the phenotypic effect observed.

  4. ANOMALOUS PREVERTEBRAL COURSE OF THE LEFT VERTEBRAL ARTERY. Recorrido prevertebral anómalo de la arteria vertebral izquierda

    Directory of Open Access Journals (Sweden)

    Prakash B Billakanti

    2016-03-01

    Full Text Available La arteria vertebral es una de las arterias que irriga el cerebro. El conocimiento de la anatomía normal y las variantes de la arteria vertebral adquiere importancia en la práctica clínica y la radiología vascular. El origen anómalo de la arteria vertebral del arco de la aorta o cualquiera de las arterias del cuello ha sido reportado por muchos autores. En este informe se presenta una variación del curso prevertebral de la arteria vertebral izquierda. La arteria vertebral tenía su origen habitual en la arteria subclavia con un largo curso prevertebral y entraba en el foramen transversarium de la vértebra CII. El origen y recorrido de la arteria vertebral en el lado derecho fue normal. Clínicamente es importante conocer el origen y curso del segmento prevertebral de la arteria vertebral y las posibles variaciones. El presente informe debería ser de interés para el médico vascular con respecto a las variaciones en el cuello y región torácica, y puede dar idea para dilucidar el mecanismo de desarrollo de la angiogénesis. Vertebral artery is one of the arteries supplying the brain. Knowledge of the normal and variant anatomy of the vertebral artery assumes importance in clinical practice and vascular radiology. Anomalous origins of the vertebral artery from the arch of the aorta or any one of the arteries of the neck have been reported by several authors. In this report a variation of the prevertebral course of the left vertebral artery is being presented. The Vertebral artery had usual origin from the subclavian artery and had a longer prevertebral course to enter the foramen transversarium of the CII vertebra. The origin and course of the vertebral artery on the right side was normal. It is clinically important to know the origin and course of the prevertebral segment of the vertebral artery and possible variations. The present report should be of interest for clinicians with regard to vascular variations in the neck and thoracic

  5. New trends and techniques in chromosome aberration analysis

    International Nuclear Information System (INIS)

    Bender, M.A.

    1978-01-01

    The following topics are discussed: automation of chromosome analysis; storage of fixed cells from cultures of lymphocytes obtained routinely during periodic employee medical examinations; analysis of banded chromosomes; identification of first division metaphases; sister chromatid exchange; and patterns of aberration induction

  6. Chromosome aberrations in Norwegian reindeer following the Chernobyl accident

    International Nuclear Information System (INIS)

    Røed, K.H.; Jacobsen, M.

    1995-01-01

    Chromosome analyses were carried out on peripheral blood lymphocytes of semi-domestic reindeer in Norway which had been exposed to varying amounts of radiocesium emanating from the Chernobyl accident. The sampling was done in the period 1987-1990. The material included 192 reindeer, originating from four herds in central Norway, an area considerably affected by fallout from the Chernobyl accident, and from three herds in northern Norway which was unaffected by fallout from the accident. Significant heterogeneity in the distribution of chromosome aberrations between herds was observed. The pattern of chromosome aberration frequencies between herds was not related to the variation in radiocesium exposure from the Chernobyl accident. Other factors than the Chernobyl accident appear therefore to be of importance for the distribution of aberration frequencies found among present herds. Within the most contaminated area the reindeer born in 1986 showed significantly more chromosome aberrations than those born both before and after 1986. This could suggest that the Chernobyl accident fallout created an effect particularly among calves, during the immediate post-accident period in the most exposed areas

  7. Effects of ocular aberrations on contrast detection in noise.

    Science.gov (United States)

    Liang, Bo; Liu, Rong; Dai, Yun; Zhou, Jiawei; Zhou, Yifeng; Zhang, Yudong

    2012-08-06

    We use adaptive optics (AO) techniques to manipulate the ocular aberrations and elucidate the effects of these ocular aberrations on contrast detection in a noisy background. The detectability of sine wave gratings at frequencies of 4, 8, and 16 circles per degree (cpd) was measured in a standard two-interval force-choice staircase procedure against backgrounds of various levels of white noise. The observer's ocular aberrations were either corrected with AO or left uncorrected. In low levels of external noise, contrast detection thresholds are always lowered by AO correction, whereas in high levels of external noise, they are generally elevated by AO correction. Higher levels of external noise are required to make this threshold elevation observable when signal spatial frequencies increase from 4 to 16 cpd. The linear-amplifier-model fit shows that mostly sampling efficiency and equivalent noise both decrease with AO correction. Our findings indicate that ocular aberrations could be beneficial for contrast detection in high-level noises. The implications of these findings are discussed.

  8. Telomere Length in Circulating Lymphocytes: Association with Chromosomal Aberrations

    Czech Academy of Sciences Publication Activity Database

    Hemminki, K.; Rachakonda, S.; Musak, L.; Vymetálková, Veronika; Halasová, E.; Forsti,, A.; Vodičková, Ludmila; Buchancová, J.; Vodička, Pavel; Kumar, R.

    2015-01-01

    Roč. 54, č. 3 (2015), s. 194-196 ISSN 1045-2257 Institutional support: RVO:68378041 Keywords : structural chromosome aberrations * healthy subjects * relative telomere length * genotoxicity * telomere biology Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.960, year: 2015

  9. Joint denoising, demosaicing, and chromatic aberration correction for UHD video

    Science.gov (United States)

    Jovanov, Ljubomir; Philips, Wilfried; Damstra, Klaas Jan; Ellenbroek, Frank

    2017-09-01

    High-resolution video capture is crucial for numerous applications such as surveillance, security, industrial inspection, medical imaging and digital entertainment. In the last two decades, we are witnessing a dramatic increase of the spatial resolution and the maximal frame rate of video capturing devices. In order to achieve further resolution increase, numerous challenges will be facing us. Due to the reduced size of the pixel, the amount of light also reduces, leading to the increased noise level. Moreover, the reduced pixel size makes the lens imprecisions more pronounced, which especially applies to chromatic aberrations. Even in the case when high quality lenses are used some chromatic aberration artefacts will remain. Next, noise level additionally increases due to the higher frame rates. To reduce the complexity and the price of the camera, one sensor captures all three colors, by relying on Color Filter Arrays. In order to obtain full resolution color image, missing color components have to be interpolated, i.e. demosaicked, which is more challenging than in the case of lower resolution, due to the increased noise and aberrations. In this paper, we propose a new method, which jointly performs chromatic aberration correction, denoising and demosaicking. By jointly performing the reduction of all artefacts, we are reducing the overall complexity of the system and the introduction of new artefacts. In order to reduce possible flicker we also perform temporal video enhancement. We evaluate the proposed method on a number of publicly available UHD sequences and on sequences recorded in our studio.

  10. Using Aberrant Behaviors as Reinforcers for Autistic Children.

    Science.gov (United States)

    Charlop, Marjorie H.; And Others

    1990-01-01

    Three experiments assessed the efficacy of various reinforcers to increase correct task responding in a total of 10 autistic children, aged 6-9. Of the reinforcers used (stereotypy, delayed echolalia, perseverative behavior, and food), task performance was highest with opportunities to engage in aberrant behaviors, and lowest with edible…

  11. Chromosome aberrations and cell survival in irradiated mammalian cells

    International Nuclear Information System (INIS)

    Tremp, J.

    1981-01-01

    A possible correlation between chromosome aberrations and reduced proliferation capacity or cell death was investigated. Synchronized Chinese hamster fibroblast cells were irradiated with 300 rad of x rays in early G 1 . Despite synchronization the cells reached the subsequent mitosis at different times. The frequency of chromosome aberrations was determined in the postirradiation division at 2-h intervals. The highest frequency occurred in cells with a first cell cycle of medium length. The colony-forming ability of mitotic cells was measured in parallel samples by following the progress of individual mitoses. The proportion of cells forming macrocolonies decreased with increasing cell cycle length, and the number of non-colony-forming cells increased. Irrespective of various first cell cycle lengths and different frequencies of chromosome aberrations, the number of cells forming microcolonies remained constant. A correlation was found between the absence of chromosome aberrations and the ability of cells to form macrocolonies. However, cells with a long first cell cycle formed fewer macrocolonies than expected

  12. Refractive and diffractive neutron optics with reduced chromatic aberration

    DEFF Research Database (Denmark)

    Poulsen, Stefan Othmar; Poulsen, Henning Friis; Bentley, P.M.

    2014-01-01

    by the use of optics for focusing and imaging. Refractive and diffractive optical elements, e.g. compound refractive lenses and Fresnel zone plates, are attractive due to their low cost, and simple alignment. These optical elements, however, suffer from chromatic aberration, which limit their effectiveness...

  13. Frequency of primary amenorrhea due to chromosomal aberration

    International Nuclear Information System (INIS)

    Jabbar, S.

    2004-01-01

    Objective: To find out the frequency of primary amenorrhea due to chromosomal aberration and the different options available for management. Subjects and Methods: All patients with primary amenorrhea due to chromosomal aberrations were included in study. Patient's detailed history, general physical examination, presence or absence of secondary sexual characteristics, abdominal and pelvic examination finding were noted. Targeted investigations, including ultrasound, hormonal assay, buccal smear and karyotyping results were recorded. The management options were individually tailored with focus n psychological management. Results: Eighteen patients out of 30,000 patients were diagnosed as having primary amenorrhea. Six had primary amenorrhea due to chromosomal aberrations with the frequency of 0.02%. The age at presentation was 20 years and above in 50%. The most common cause was Turner's syndrome seen in 4 out of 6. The presenting symptoms were delay in onset of menstruation in 05 patients and primary infertility in 01 patient. Conclusion: Primary amenorrhea due to chromosomal aberration is an uncommon condition requiring an early and accurate diagnosis. Turner's syndrome is a relatively common cause of this condition. Management should be multi-disciplinary and individualized according to the patient's age and symptom at presentation. Psychological management is very important and counselling throughout treatment is recommended. (author)

  14. Thermal lensing measurement from the coefficient of defocus aberration

    CSIR Research Space (South Africa)

    Bell, Teboho

    2016-03-01

    Full Text Available We measured the thermally induced lens from the coefficient of defocus aberration using a Shack-Hartmann wavefront sensor (SHWFS). As a calibration technique, we infer the focal length of standard lenses probed by a collimated Gaussian beam...

  15. Thermally induced lensing determination from the coefficient of defocus aberration

    CSIR Research Space (South Africa)

    Bell, Teboho

    2014-07-01

    Full Text Available The effects of a temperature gradient in a laser crystal in an end-pumped configuration in a solid-state laser resonator results in thermally induced aberrations. Of particular interest we measure the thermally induced lens from the coefficient...

  16. Iatrogenic injury of an aberrant right posterior sectoral bile duct

    African Journals Online (AJOL)

    (Figs 1 and 2). A week later, an endoscopic retrograde cholangiopancreatography. (ERCP) examination was performed. This showed no filling of the right posterior sectoral ducts but normal opacification of the other ducts. (Figs 3a and b). These findings led to the diagnosis of an aberrant right posterior sectoral bile duct that ...

  17. Chromosomal aberrations in tire plant workers and interaction with

    Czech Academy of Sciences Publication Activity Database

    Musak, L.; Souček, P.; Vodičková, Ludmila; Naccarati, Alessio; Halasová, E.; Poláková, Veronika; Slyšková, Jana; Susová, S.; Buchancová, J.; Šmerhovský, Z.; Sediková, J.; Klimentová, G.; Osina, O.; Hemminki, K.; Vodička, Pavel

    2008-01-01

    Roč. 641, 1-2 (2008), s. 36-42 ISSN 0027-5107 R&D Projects: GA MZd NR8563 Institutional research plan: CEZ:AV0Z50390512 Keywords : Chromosomal aberrations * Genetic polymorphisms * DNA repair genes Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.198, year: 2008

  18. Oxidative stress and chromosomal aberrations in an environmentally exposed population

    Czech Academy of Sciences Publication Activity Database

    Rössner ml., Pavel; Rössnerová, Andrea; Šrám, Radim

    2011-01-01

    Roč. 707, 1-2 (2011), s. 34-41 ISSN 0027-5107 R&D Projects: GA MŽP(CZ) SP/1B3/8/08 Institutional research plan: CEZ:AV0Z50390512 Keywords : air pollution * oxidative stress * chromosomal aberrations Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 2.850, year: 2011

  19. Aberrant nerve fibres within the central nervous system.

    Science.gov (United States)

    Moffie, D

    1992-01-01

    Three cases of aberrant nerve fibres in the spinal cord and medulla oblongata are described. The literature on these fibres is discussed and their possible role in regeneration. Different views on the possibility of regeneration or functional recovery of the central nervous system are mentioned in the light of recent publications, which are more optimistic than before.

  20. The Aberrant Salience Inventory: A New Measure of Psychosis Proneness

    Science.gov (United States)

    Cicero, David C.; Kerns, John G.; McCarthy, Denis M.

    2010-01-01

    Aberrant salience is the unusual or incorrect assignment of salience, significance, or importance to otherwise innocuous stimuli and has been hypothesized to be important for psychosis and psychotic disorders such as schizophrenia. Despite the importance of this concept in psychosis research, no questionnaire measures are available to assess…

  1. Holographic gratings for spectrographic applications: Study of aberrations

    Science.gov (United States)

    Bhatia, M. S.

    1975-01-01

    The design and fabrication of holographic gratings requires an understanding of Fermat's principle. This principle states that the path of a light ray from one point to another is that which requires the least time. The aberrant, optical path of an object point to an image was studied using Fermat principles.

  2. Persistent truncus arteriosis associated with interruption of the aortic arch.

    Science.gov (United States)

    Nath, P H; Zollikofer, C; Castaneda-Zuniga, W; Formanek, A; Amplatz, K

    1980-09-01

    Five patients with a combination of truncus arteriosus and interruption of the aortic arch are reported. The combination of those defects significantly increases the surgical risk. This rare cardiac malformation can only be diagnosed radiographically. An aberrant right subclavian artery is present in 25% of patients. It is helpful in suspecting the diagnosis from plain films of the chest. The diagnosis can be made from a ventriculogram, but usually a truncogram is necessary to define the anatomy of the aortic arch.

  3. Abnormal innominate vein and right aortic arch, an uncommon association that should be taken into account

    International Nuclear Information System (INIS)

    Catala, J.; Martin, C.

    2000-01-01

    A case of abnormal innominate vein associated with right aortic arch and aberrant left subclavian artery is presented. It was an incidental finding during the radiological study of an 8-year old boy suspected of having tuberculosis. The authors review the different etiological theories, radiological features and diagnostic impact of this uncommon venous malformation, as well as its relationship to other cardiovascular anomalies. (Author) 9 refs

  4. Lethality of radiation-induced chromosome aberrations in human tumour cell lines with different radiosensitivities.

    Science.gov (United States)

    Coco-Martin, J M; Ottenheim, C P; Bartelink, H; Begg, A C

    1996-03-01

    In order to find an explanation for the eventual disappearance of all chromosome aberrations in two radiosensitive human tumour cell lines, the type and stability of different aberration types was investigated in more detail. To classify the aberrations into unstable and stable types, three-colour fluorescence in situ hybridization was performed, including a whole-chromosome probe, a pancentromere probe, and a stain for total DNA. This technique enables the appropriate classification of the aberrations principally by the presence (stable) or not (unstable) of a single centromere per chromosome. Unstable-type aberrations were found to disappear within 7 days (several divisions) in the two radiosensitive and the two radioresistant tumour lines investigated. Stable-type aberrations were found to remain at an approximately constant level over the duration of the experiment (14 days; 8-10 divisions) in the two radioresistant lines. In contrast, the majority of these stable-type aberrations had disappeared by 14 days in the two radiosensitive lines. The previous findings of disappearance of total aberrations in radiosensitive cells was therefore not due to a reduced induction of stable-type aberrations, but the complete disappearance of cells with this aberration type. These results could not be explained by differences in apoptosis or G1 blocks. Two possible explanations for these unexpected findings involve non-random induction of unstable-type aberrations, or lethality of stable-type aberrations. The results suggest caution in the use of stable-type aberration numbers as a predictor for radiosensitivity.

  5. Chromatin structure and ionizing-radiation-induced chromosome aberrations

    International Nuclear Information System (INIS)

    Muehlmann-Diaz, M.C.

    1993-01-01

    The possible influence of chromatic structure or activity on chromosomal radiosensitivity was studied. A cell line was isolated which contained some 10 5 copies of an amplified plasmid in a single large mosquito artificial chromosome (MAC). This chromosome was hypersensitive to DNase I. Its radiosensitivity was some three fold greater than normal mosquito chromosomes in the same cell. In cultured human cells irradiated during G 0 , the initial breakage frequency in chromosome 4, 19 and the euchromatic and heterochromatic portions of the Y chromosome were measured over a wide range of doses by inducing Premature Chromosome Condensation (PCC) immediately after irradiation with Cs-137 gamma rays. No evidence was seen that Y heterochromatin or large fragments of it remained unbroken. The only significant deviation from the expected initial breakage frequency per Gy per unit length of chromosome was that observed for the euchromatic portion of the Y chromosome, with breakage nearly twice that expected. The development of aberrations involving X and Y chromosomes at the first mitosis after irradation was also studied. Normal female cells sustained about twice the frequency of aberrations involving X chromosomes for a dose of 7.3 Gy than the corresponding male cells. Fibroblasts from individuals with supernumerary X chromosomes did not show any further increase in X aberrations for this dos. The frequency of aberrations involving the heterochromatic portion of the long arm of the Y chromosome was about what would be expected for a similar length of autosome, but the euchromatic portion of the Y was about 3 times more radiosensitive per unit length. 5-Azacytidine treatment of cultured human female fibroblasts or fibroblasts from a 49,XXXXY individual, reduced the methylation of cytosine residues in DNA, and resulted in an increased chromosomal radiosensitivity in general, but it did not increase the frequency of aberrations involving the X chromosomes

  6. Hepaticocystic duct and a rare extra-hepatic "cruciate" arterial anastomosis: a case report

    Directory of Open Access Journals (Sweden)

    Abeysuriya Vasitha

    2008-02-01

    Full Text Available Abstract Introduction The variations in the morphological characteristics of the extra-hepatic biliary system are interesting. Case presentation During the dissection of cadavers to study the morphological characteristics of the extra-hepatic biliary system, a 46-year-old male cadaver was found to have drainage of the common hepatic duct drains directly into the gall bladder neck. The right and left hepatic ducts were not seen extra-hepatically. Further drainage of the bile away from the gallbladder and into the duodenum was provided by the cystic duct. Formation of the common bile duct by the union of the common hepatic duct and cystic duct was absent. Further more the right hepatic artery was found to be communicating with the left hepatic artery by a "bridging artery" after giving rise to the cystic artery. An accessory hepatic artery originated from the "bridging artery" forming a "cruciate" hepatic arterial anastomosis. Conclusion Combination of a Hepaticocystic duct and an aberrant variation in the extra-hepatic arterial system is extremely rare.

  7. Subjective face recognition difficulties, aberrant sensibility, sleeping disturbances and aberrant eating habits in families with Asperger syndrome

    Directory of Open Access Journals (Sweden)

    Källman Tiia

    2005-04-01

    Full Text Available Abstract Background The present study was undertaken in order to determine whether a set of clinical features, which are not included in the DSM-IV or ICD-10 for Asperger Syndrome (AS, are associated with AS in particular or whether they are merely a familial trait that is not related to the diagnosis. Methods Ten large families, a total of 138 persons, of whom 58 individuals fulfilled the diagnostic criteria for AS and another 56 did not to fulfill these criteria, were studied using a structured interview focusing on the possible presence of face recognition difficulties, aberrant sensibility and eating habits and sleeping disturbances. Results The prevalence for face recognition difficulties was 46.6% in individuals with AS compared with 10.7% in the control group. The corresponding figures for subjectively reported presence of aberrant sensibilities were 91.4% and 46.6%, for sleeping disturbances 48.3% and 23.2% and for aberrant eating habits 60.3% and 14.3%, respectively. Conclusion An aberrant processing of sensory information appears to be a common feature in AS. The impact of these and other clinical features that are not incorporated in the ICD-10 and DSM-IV on our understanding of AS may hitherto have been underestimated. These associated clinical traits may well be reflected by the behavioural characteristics of these individuals.

  8. Study of chromosome aberrations on the workers occupationally exposed to thorium and rare earth mixed dust

    International Nuclear Information System (INIS)

    Zhang Wei; Wang Chunyan; Lv Huiming; Zhang Cuilan; Hao Shuxia; Su Xu; Jia Kejun; Liu Yufei

    2008-01-01

    Objective: To study the effect of thorium and rare earth mixed dust on chromosome aberrations in the lymphocytes of occupational exposed workers. Methods: Analyses of unstable chromosome aberrations on 53 occupational exposed workers and 58 control workers were carried out by the conventional Giemsa staining method. Fluorescence in situ hybridization method was performed to analyze the chromosome stable aberrations on 10 occupational exposed workers and l0 control workers. Results: The frequencies of chromosomal aberration cells, dicentrics plus rings, total aberrations in exposed workers were significantly higher than those in controls. No significant difference was found in the frequency of acentric aberrations between exposed and non-exposed workers. No significant difference was found in the frequency of translocations between exposed and non-exposed workers. Conclusions: Chronically occupational exposure to thorium and rare earth mixed dust can increase the induction of unstable chromosome aberration, but the increase of stable chromosome aberrations (translocation) can not be observed. (authors)

  9. An accurate optical design method for synchrotron radiation beamlines with wave-front aberration theory

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xiaojiang, E-mail: slsyxj@nus.edu.sg; Diao, Caozheng; Breese, Mark B. H. [Singapore Synchrotron Light Source, National University of Singapore, Singapore 117603 (Singapore)

    2016-07-27

    An aberration calculation method which was developed by Lu [1] can treat individual aberration term precisely. Spectral aberration is the linear sum of these aberration terms, and the aberrations of multi-element systems also can be calculated correctly when the stretching ratio, defined herein, is unity. Evaluation of focusing mirror-grating systems which are optimized according to Lu’s method, along with the Light Path Function (LPF) and the Spot Diagram method (SD) are discussed to confirm the advantage of Lu’s methodology. Lu’s aberration terms are derived from a precise wave-front treatment, whereas the terms of the power series expansion of the light path function do not yield an accurate sum of the aberrations. Moreover, Lu’s aberration terms can be individually optimized. This is not possible with the analytical spot diagram formulae.

  10. Renal artery stenosis

    International Nuclear Information System (INIS)

    Desberg, A.; Paushter, D.M.; Lammert, G.K.; Hale, J.; Troy, R.; Novic, A.; Nally, J. Jr.

    1989-01-01

    Renal artery disease is a potentially correctable cause of hypertension. Previous studies have suggested the utility of duplex sonography in accurately detecting and grading the severity of renal artery stenosis. The purpose of this paper is to evaluate color flow Doppler for this use. Forty-three kidneys were examined by color-flow Doppler and conventional duplex sampling in patients with suspected renovascular hypertension or those undergoing aortography for unrelated reasons. Doppler tracings were obtained from the renal arteries and aorta with calculation of the renal aortic ratio (RAR) and resistive index (RI). Results of Doppler sampling with color flow guidance were compared with aortograms in a blinded fashion

  11. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  12. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  13. Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.

    Science.gov (United States)

    Kari, Fabian A; Wittmann, Karin; Krause, Sonja; Saravi, Babak; Puttfarcken, Luisa; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2017-12-01

    The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model. Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1). The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  15. The effect of aberrated recording beams on reflecting Bragg gratings

    Science.gov (United States)

    SeGall, Marc; Ott, Daniel; Divliansky, Ivan; Glebov, Leonid B.

    2013-03-01

    The effect of aberrations present in the recording beams of a holographic setup is discussed regarding the period and spectral response of a reflecting volume Bragg grating. Imperfect recording beams result in spatially varying resonant wavelengths and the side lobes of the spectrum are washed out. Asymmetrical spectra, spectral broadening, and a reduction in peak diffraction efficiency may also be present, though these effects are less significant for gratings with wider spectral widths. Reflecting Bragg gratings (RBGs) are used as elements in a variety of applications including spectral beam combining1,2, mode locking3,4, longitudinal and transverse mode selection in lasers5,6, and sensing7,8. For applications requiring narrow spectral selectivity9, or large apertures10, these gratings must have a uniform period throughout the length of the recording medium, which may be on the order of millimeters. However, when using typical recording techniques such as two-beam interference for large aperture gratings and phase-mask recording of fiber gratings, aberrations from the optical elements in the system result in an imperfect grating structure11-13. In this paper we consider the effects of aberrations on large aperture gratings recorded in thick media using the two-beam interference technique. Previous works in analyzing the effects of aberrations have considered the effects of aberrations in a single recording plane where the beams perfectly overlap. Such an approach is valid for thin media (on the order of tens of microns), but for thick recording media (on the order of several millimeters) there will be a significant shift in the positions of the beams relative to each other as they traverse the recording medium. Therefore, the fringe pattern produced will not be constant throughout the grating if one or both beams have a non-uniform wavefront. Such non-uniform gratings may have a wider spectral width, a shifted resonant wavelength, or other problems. It is

  16. Nodular Hyperplasia Arising from the Lateral Aberrant Thyroid Tissue: A Case Report

    International Nuclear Information System (INIS)

    Jeong, Min Hye; Park, Jeong Seon; Lee, Young Jun

    2012-01-01

    The presence of aberrant thyroid tissue in the lateral neck is very rare. In addition, nodular hyperplasia in ectopic thyroid has rarely been reported. Due to the unusual location, the presence of lateral aberrant thyroid tissue could be misdiagnosed as a lymphadenopathy, neurogenic tumor, etc. We report on a case of nodular hyperplasia arising from the right lateral aberrant thyroid tissue.

  17. Image transfer with spatial coherence for aberration corrected transmission electron microscopes

    International Nuclear Information System (INIS)

    Hosokawa, Fumio; Sawada, Hidetaka; Shinkawa, Takao; Sannomiya, Takumi

    2016-01-01

    The formula of spatial coherence involving an aberration up to six-fold astigmatism is derived for aberration-corrected transmission electron microscopy. Transfer functions for linear imaging are calculated using the newly derived formula with several residual aberrations. Depending on the symmetry and origin of an aberration, the calculated transfer function shows characteristic symmetries. The aberrations that originate from the field’s components, having uniformity along the z direction, namely, the n-fold astigmatism, show rotational symmetric damping of the coherence. The aberrations that originate from the field’s derivatives with respect to z, such as coma, star, and three lobe, show non-rotational symmetric damping. It is confirmed that the odd-symmetric wave aberrations have influences on the attenuation of an image via spatial coherence. Examples of image simulations of haemoglobin and Si [211] are shown by using the spatial coherence for an aberration-corrected electron microscope. - Highlights: • The formula of partial coherence for aberration corrected TEM is derived. • Transfer functions are calculated with several residual aberrations. • The calculated transfer function shows the characteristic damping. • The odd-symmetric wave aberrations can cause the attenuation of image via coherence. • The examples of aberration corrected TEM image simulations are shown.

  18. Detecting Aberrant Response Patterns in the Rasch Model. Rapport 87-3.

    Science.gov (United States)

    Kogut, Jan

    In this paper, the detection of response patterns aberrant from the Rasch model is considered. For this purpose, a new person fit index, recently developed by I. W. Molenaar (1987) and an iterative estimation procedure are used in a simulation study of Rasch model data mixed with aberrant data. Three kinds of aberrant response behavior are…

  19. Image transfer with spatial coherence for aberration corrected transmission electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Fumio, E-mail: hosokawa@bio-net.co.jp [BioNet Ltd., 2-3-28 Nishikityo, Tachikwa, Tokyo (Japan); Tokyo Institute of Technology, 4259 Nagatsuta, Midoriku, Yokohama 226-8503 (Japan); Sawada, Hidetaka [JEOL (UK) Ltd., JEOL House, Silver Court, Watchmead, Welwyn Garden City, Herts AL7 1LT (United Kingdom); Shinkawa, Takao [BioNet Ltd., 2-3-28 Nishikityo, Tachikwa, Tokyo (Japan); Sannomiya, Takumi [Tokyo Institute of Technology, 4259 Nagatsuta, Midoriku, Yokohama 226-8503 (Japan)

    2016-08-15

    The formula of spatial coherence involving an aberration up to six-fold astigmatism is derived for aberration-corrected transmission electron microscopy. Transfer functions for linear imaging are calculated using the newly derived formula with several residual aberrations. Depending on the symmetry and origin of an aberration, the calculated transfer function shows characteristic symmetries. The aberrations that originate from the field’s components, having uniformity along the z direction, namely, the n-fold astigmatism, show rotational symmetric damping of the coherence. The aberrations that originate from the field’s derivatives with respect to z, such as coma, star, and three lobe, show non-rotational symmetric damping. It is confirmed that the odd-symmetric wave aberrations have influences on the attenuation of an image via spatial coherence. Examples of image simulations of haemoglobin and Si [211] are shown by using the spatial coherence for an aberration-corrected electron microscope. - Highlights: • The formula of partial coherence for aberration corrected TEM is derived. • Transfer functions are calculated with several residual aberrations. • The calculated transfer function shows the characteristic damping. • The odd-symmetric wave aberrations can cause the attenuation of image via coherence. • The examples of aberration corrected TEM image simulations are shown.

  20. Popliteal Arterial Aneurysms

    African Journals Online (AJOL)

    plication was acute arterial occlusion caused by thrombo- embolism. The reasons for ... Total. 43. 55. TABLE 11. CONCOMITANT DISEASE IN 38 PATIENTS .... Dacron prosthesis in 4. .... genous saphenous vein and the type of anastomosis.

  1. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  2. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  3. Aberrant Cerebral Blood Flow in Response to Hunger and Satiety in Women Remitted from Anorexia Nervosa

    Directory of Open Access Journals (Sweden)

    Christina E. Wierenga

    2017-07-01

    Full Text Available The etiology of pathological eating in anorexia nervosa (AN remains poorly understood. Cerebral blood flow (CBF is an indirect marker of neuronal function. In healthy adults, fasting increases CBF, reflecting increased delivery of oxygen and glucose to support brain metabolism. This study investigated whether women remitted from restricting-type AN (RAN have altered CBF in response to hunger that may indicate homeostatic dysregulation contributing to their ability to restrict food. We compared resting CBF measured with pulsed arterial spin labeling in 21 RAN and 16 healthy comparison women (CW when hungry (after a 16-h fast and after a meal. Only remitted subjects were examined to avoid the confounding effects of malnutrition on brain function. Compared to CW, RAN demonstrated a reduced difference in the Hungry − Fed CBF contrast in the right ventral striatum, right subgenual anterior cingulate cortex (pcorr < 0.05 and left posterior insula (punc < 0.05; RAN had decreased CBF when hungry versus fed, whereas CW had increased CBF when hungry versus fed. Moreover, decreased CBF when hungry in the left insula was associated with greater hunger ratings on the fasted day for RAN. This represents the first study to show that women remitted from AN have aberrant resting neurovascular function in homeostatic neural circuitry in response to hunger. Regions involved in homeostatic regulation showed group differences in the Hungry − Fed contrast, suggesting altered cellular energy metabolism in this circuitry that may reduce motivation to eat.

  4. Aberrations and adaptive optics in super-resolution microscopy

    Science.gov (United States)

    Booth, Martin; Andrade, Débora; Burke, Daniel; Patton, Brian; Zurauskas, Mantas

    2015-01-01

    As one of the most powerful tools in the biological investigation of cellular structures and dynamic processes, fluorescence microscopy has undergone extraordinary developments in the past decades. The advent of super-resolution techniques has enabled fluorescence microscopy – or rather nanoscopy – to achieve nanoscale resolution in living specimens and unravelled the interior of cells with unprecedented detail. The methods employed in this expanding field of microscopy, however, are especially prone to the detrimental effects of optical aberrations. In this review, we discuss how super-resolution microscopy techniques based upon single-molecule switching, stimulated emission depletion and structured illumination each suffer from aberrations in different ways that are dependent upon intrinsic technical aspects. We discuss the use of adaptive optics as an effective means to overcome this problem. PMID:26124194

  5. Chromosome Aberrations in Human Lymphocytes Irradiated with Ionizing Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Tae Ho; Kim, Jin Hong; Kim, Jin Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The purpose of the present experiment was to provide data on the dose-dependent production of chromosome aberrations such as dicentrics, centric rings, and excess acentrics. Radiation is one of the more dangerous clastogens in the environment. Ionizing radiation causes chromosome breakages and various cytogenetic aberrations in exposed cells. In an investigation into radiation emergencies, it is important to estimate the dose to exposed persons for several reasons. Physical dosimeters (e. g., film badges) may misrepresent the actual radiation dose and may not be available in a radiological accident or terrorism incident. Biological dosimetry is suitable for estimating the radiation dose during such accidents. The dicentric chromosome assay is very sensitive and a reliable bio-indicator in cases of accidental overexposure.

  6. Retrospective chromosome aberration analysis of former uranium miners

    International Nuclear Information System (INIS)

    Meszaros, G.; Bognar, G.; Koeteles, G. J.

    2003-01-01

    In this paper we present our data collected in the period of 1981-1985 on 165 persons exposed by different radon concentrations expressed in working level month (WLM) units from 100 up to 600. Following the decommissioning of the uranium mine in Hungary in 1997 cytogenetic status of 131 persons were within a follow-up-study of their health conditions initiated by the Hungarian Academy of Science. The persons have terminated their underground activities 5 to 20 years before testing. The comparison of the two datasets suggest a long-term persistence of cytogenetic alterations above the population average values in large percentages of persons investigated. The frequency of chromosome aberrations of uranium miners was found increased in function of their exposure to radon. The comparison of the miner's categories 20 years ago and in the recent years demonstrated the long-term existence of aberrations for many years after completion of underground mining activities. (authors)

  7. Measuring chromatic aberrations in imaging systems using plasmonic nanoparticles.

    Science.gov (United States)

    Gennaro, Sylvain D; Roschuk, Tyler R; Maier, Stefan A; Oulton, Rupert F

    2016-04-01

    We demonstrate a method to measure chromatic aberrations of microscope objectives with metallic nanoparticles using white light. Extinction spectra are recorded while scanning a single nanoparticle through a lens's focal plane. We show a direct correlation between the focal wavelength and the longitudinal chromatic focal shift through our analysis of the variations between the scanned extinction spectra at each scan position and the peak extinction over the entire scan. The method has been tested on achromat and apochromat objectives using aluminum disks varying in size from 260-520 nm. Our method is straightforward, robust, low cost, and broadband with a sensitivity suitable for assessing longitudinal chromatic aberrations in high-numerical-aperture apochromatic corrected lenses.

  8. Chromosome aberration induction in human diploid fibroblast and epithelial cells

    International Nuclear Information System (INIS)

    Scott, D.

    1986-01-01

    The relative sensitivity of cultured human fibroblasts and epithelial cells to radiation-induced chromosomal aberrations was investigated. Lung fibroblast and kidney epithelial cells from the same fetus were compared, as were skin fibroblasts and epithelial keratinocytes from the same foreskin sample. After exposure of proliferating fetal cells to 1.5 Gy X-rays there was a very similar aberration yield in the fibroblasts and epithelial cells. Observations of either little or no difference in chromosomal sensitivity between human fibroblasts and epithelial cells give added confidence that quantitative cytogenetic data obtained from cultured fibroblasts are relevant to the question of sensitivity of epithelial cells which are the predominant cell type in human cancers. (author)

  9. Evaluation of an automated karyotyping system for chromosome aberration analysis

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1987-01-01

    Chromosome aberration analysis is a promising complement to conventional radiation dosimetry, particularly in the complex radiation fields encountered in the space environment. The capabilities of a recently developed automated karyotyping system were evaluated both to determine current capabilities and limitations and to suggest areas where future development should be emphasized. Cells exposed to radiometric chemicals and to photon and particulate radiation were evaluated by manual inspection and by automated karyotyping. It was demonstrated that the evaluated programs were appropriate for image digitization, storage, and transmission. However, automated and semi-automated scoring techniques must be advanced significantly if in-flight chromosome aberration analysis is to be practical. A degree of artificial intelligence may be necessary to realize this goal

  10. Chromosomal aberrations and micronuclei frequencies in Bulgarian control population

    International Nuclear Information System (INIS)

    Popova, I.; Hadjidekova, V.; Hristova, R.; Atanasova, P.

    2004-01-01

    The aim of this investigation is to represent the frequency of spontaneous chromosomal damages in peripheral blood lymphocytes of Bulgarian control population. Material and methods: The investigated group includes persons belonging to both sexes and different ages. Each of them is interviewed of their social and health status. Sixteen persons are examined using the chromosomal aberrations analysis and forty-five with micronucleus test. The frequency of chromosomal aberrations varied between 0 - 2.4 % and the mean value is 1.00 %. The frequency of cells with micronuclei varied between 4.5 - 24.5 % and the mean value 12,9 %. Further work on the investigation of spontaneous frequency of chromosomal damages is in progress. (authors)

  11. Chromosome Aberration on High Level Background Natural Radiation Areas

    International Nuclear Information System (INIS)

    Yanti-Lusiyanti; Zubaidah-Alatas

    2001-01-01

    When the body is irradiated, all cells can suffer cytogenetic damage that can be seen as structural damage of chromosome in the lymphocytes. People no matter where they live in world are exposed to background radiation from natural sources both internal and external such as cosmic radiation, terrestrial radiation, cosmogenic radiation radon and thoron. Level of area natural ionizing radiation is varies depending on the altitude, the soil or rock conditions, particular food chains and the building materials and construction features. Level of normal areas of background exposure is annual effective dose 2.4 mSv and the high level areas of background exposure 20 mSv. This paper discuses the frequency of aberration chromosome especially dysenteries in several countries having high level radiation background. It seems that frequency of chromosome aberrations increase, generally with the increase of age of the people and the accumulated dose received. (author)

  12. Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

    Science.gov (United States)

    Reddy, A. N. K.; Sagar, D. K.; Khonina, S. N.

    2017-12-01

    Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

  13. Integral image rendering procedure for aberration correction and size measurement.

    Science.gov (United States)

    Sommer, Holger; Ihrig, Andreas; Ebenau, Melanie; Flühs, Dirk; Spaan, Bernhard; Eichmann, Marion

    2014-05-20

    The challenge in rendering integral images is to use as much information preserved by the light field as possible to reconstruct a captured scene in a three-dimensional way. We propose a rendering algorithm based on the projection of rays through a detailed simulation of the optical path, considering all the physical properties and locations of the optical elements. The rendered images contain information about the correct size of imaged objects without the need to calibrate the imaging device. Additionally, aberrations of the optical system may be corrected, depending on the setup of the integral imaging device. We show simulation data that illustrates the aberration correction ability and experimental data from our plenoptic camera, which illustrates the capability of our proposed algorithm to measure size and distance. We believe this rendering procedure will be useful in the future for three-dimensional ophthalmic imaging of the human retina.

  14. Fixational eye movement: a negligible source of dynamic aberration.

    Science.gov (United States)

    Mecê, Pedro; Jarosz, Jessica; Conan, Jean-Marc; Petit, Cyril; Grieve, Kate; Paques, Michel; Meimon, Serge

    2018-02-01

    To evaluate the contribution of fixational eye movements to dynamic aberration, 50 healthy eyes were examined with an original custom-built Shack-Hartmann aberrometer, running at a temporal frequency of 236Hz, with 22 lenslets across a 5mm pupil, synchronized with a 236Hz pupil tracker. A comparison of the dynamic behavior of the first 21 Zernike modes (starting from defocus) with and without digital pupil stabilization, on a 3.4s sequence between blinks, showed that the contribution of fixational eye movements to dynamic aberration is negligible. Therefore we highlighted the fact that a pupil tracker coupled to an Adaptive Optics Ophthalmoscope is not essential to achieve diffraction-limited resolution.

  15. Deep Tissue Wavefront Estimation for Sensorless Aberration Correction

    Directory of Open Access Journals (Sweden)

    Ibrahimovic Emina

    2015-01-01

    Full Text Available The multiple light scattering in biological tissues limits the measurement depth for traditional wavefront sensor. The attenuated ballistic light and the background noise caused by the diffuse light give low signal to noise ratio for wavefront measurement. To overcome this issue, we introduced a wavefront estimation method based on a ray tracing algorithm to overcome this issue. With the knowledge of the refractive index of the medium, the wavefront is estimated by calculating optical path length of rays from the target inside of the samples. This method can provide not only the information of spherical aberration from the refractive-index mismatch between the medium and biological sample but also other aberrations caused by the irregular interface between them. Simulations based on different configurations are demonstrated in this paper.

  16. Carrier and aberrations removal in interferometric fringe projection profilometry

    Science.gov (United States)

    Blain, P.; Michel, F.; Renotte, Y.; Habraken, S.

    2012-04-01

    A profilometer which takes advantage of polarization states splitting technique and monochromatic light projection method as a way to overcome ambient lighting for in-situ measurement is under development [1, 2]. Because of the Savart plate which refracts two out of axis beams, the device suffers from aberrations (mostly coma and astigmatism). These aberrations affect the quality of the sinusoidal fringe pattern. In fringe projection profilometry, the unwrapped phase distribution map contains the sum of the object's shape-related phase and carrier-fringe-related phase. In order to extract the 3D shape of the object, the carrier phase has to be removed [3, 4]. An easy way to remove both the fringe carrier and the aberrations of the optical system is to measure the phases of the test object and to measure the phase of a reference plane with the same set up and to subtract both phase maps. This time consuming technique is suitable for laboratory but not for industry. We propose a method to numerically remove both the fringe carrier and the aberrations. A first reference phase of a calibration plane is evaluated knowing the position of the different elements in the set up and the orientation of the fringes. Then a fitting of the phase map by Zernike polynomials is computed [5]. As the triangulation parameters are known during the calibration, the computation of Zernike coefficients has only to be made once. The wavefront error can be adjusted by a scale factor which depends on the position of the test object.

  17. Studies on chromosome aberrations in workers occupationally exposed to radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Hyung; Oh, Hyeon Joo; Shim, Sun Bo; Roh, Hye Won; Lee, Hai Yong [Korea Food and Drug Administration, Seoul (Korea, Republic of); Kang, Soon Ja [Ewha Womens Univ., Seoul (Korea, Republic of)

    1998-06-01

    Cytogenetic assays for unstable chromosomes were performed on 54 medical radiation workers who are occupationally exposed to radiation and 42 controls. A total of 15,577 metaphase cells were scored. The frequencies of dicentrics and acentric chromosomes on controls were 0.52*10{sup -3} and 0.82*10{sup -2}, respectively. On radiation workers those were 2.28*10{sup -3} and 1.34*10{sup -2}, respectively. Though the frequencies of all types of chromosome aberrations in the workers were higher than those in the controls, the only significant difference was found in the case of dicentrics (P < 0.01). When we considered exposure dose of recent one year, duration of employment and smoking habit in radiation worker, a slight increase was shown in frequency of unstable chromosome aberrations on these workers, but no statistical differences were observed (P > 0.05) except exposure dose of recent one year (P < 0.05). These results could indicate that low level exposure to ionizing radiation can induce unstable chromosome aberrations in blood lymphocytes.

  18. Pancreatic cancer genomes reveal aberrations in axon guidance pathway genes.

    Science.gov (United States)

    Biankin, Andrew V; Waddell, Nicola; Kassahn, Karin S; Gingras, Marie-Claude; Muthuswamy, Lakshmi B; Johns, Amber L; Miller, David K; Wilson, Peter J; Patch, Ann-Marie; Wu, Jianmin; Chang, David K; Cowley, Mark J; Gardiner, Brooke B; Song, Sarah; Harliwong, Ivon; Idrisoglu, Senel; Nourse, Craig; Nourbakhsh, Ehsan; Manning, Suzanne; Wani, Shivangi; Gongora, Milena; Pajic, Marina; Scarlett, Christopher J; Gill, Anthony J; Pinho, Andreia V; Rooman, Ilse; Anderson, Matthew; Holmes, Oliver; Leonard, Conrad; Taylor, Darrin; Wood, Scott; Xu, Qinying; Nones, Katia; Fink, J Lynn; Christ, Angelika; Bruxner, Tim; Cloonan, Nicole; Kolle, Gabriel; Newell, Felicity; Pinese, Mark; Mead, R Scott; Humphris, Jeremy L; Kaplan, Warren; Jones, Marc D; Colvin, Emily K; Nagrial, Adnan M; Humphrey, Emily S; Chou, Angela; Chin, Venessa T; Chantrill, Lorraine A; Mawson, Amanda; Samra, Jaswinder S; Kench, James G; Lovell, Jessica A; Daly, Roger J; Merrett, Neil D; Toon, Christopher; Epari, Krishna; Nguyen, Nam Q; Barbour, Andrew; Zeps, Nikolajs; Kakkar, Nipun; Zhao, Fengmei; Wu, Yuan Qing; Wang, Min; Muzny, Donna M; Fisher, William E; Brunicardi, F Charles; Hodges, Sally E; Reid, Jeffrey G; Drummond, Jennifer; Chang, Kyle; Han, Yi; Lewis, Lora R; Dinh, Huyen; Buhay, Christian J; Beck, Timothy; Timms, Lee; Sam, Michelle; Begley, Kimberly; Brown, Andrew; Pai, Deepa; Panchal, Ami; Buchner, Nicholas; De Borja, Richard; Denroche, Robert E; Yung, Christina K; Serra, Stefano; Onetto, Nicole; Mukhopadhyay, Debabrata; Tsao, Ming-Sound; Shaw, Patricia A; Petersen, Gloria M; Gallinger, Steven; Hruban, Ralph H; Maitra, Anirban; Iacobuzio-Donahue, Christine A; Schulick, Richard D; Wolfgang, Christopher L; Morgan, Richard A; Lawlor, Rita T; Capelli, Paola; Corbo, Vincenzo; Scardoni, Maria; Tortora, Giampaolo; Tempero, Margaret A; Mann, Karen M; Jenkins, Nancy A; Perez-Mancera, Pedro A; Adams, David J; Largaespada, David A; Wessels, Lodewyk F A; Rust, Alistair G; Stein, Lincoln D; Tuveson, David A; Copeland, Neal G; Musgrove, Elizabeth A; Scarpa, Aldo; Eshleman, James R; Hudson, Thomas J; Sutherland, Robert L; Wheeler, David A; Pearson, John V; McPherson, John D; Gibbs, Richard A; Grimmond, Sean M

    2012-11-15

    Pancreatic cancer is a highly lethal malignancy with few effective therapies. We performed exome sequencing and copy number analysis to define genomic aberrations in a prospectively accrued clinical cohort (n = 142) of early (stage I and II) sporadic pancreatic ductal adenocarcinoma. Detailed analysis of 99 informative tumours identified substantial heterogeneity with 2,016 non-silent mutations and 1,628 copy-number variations. We define 16 significantly mutated genes, reaffirming known mutations (KRAS, TP53, CDKN2A, SMAD4, MLL3, TGFBR2, ARID1A and SF3B1), and uncover novel mutated genes including additional genes involved in chromatin modification (EPC1 and ARID2), DNA damage repair (ATM) and other mechanisms (ZIM2, MAP2K4, NALCN, SLC16A4 and MAGEA6). Integrative analysis with in vitro functional data and animal models provided supportive evidence for potential roles for these genetic aberrations in carcinogenesis. Pathway-based analysis of recurrently mutated genes recapitulated clustering in core signalling pathways in pancreatic ductal adenocarcinoma, and identified new mutated genes in each pathway. We also identified frequent and diverse somatic aberrations in genes described traditionally as embryonic regulators of axon guidance, particularly SLIT/ROBO signalling, which was also evident in murine Sleeping Beauty transposon-mediated somatic mutagenesis models of pancreatic cancer, providing further supportive evidence for the potential involvement of axon guidance genes in pancreatic carcinogenesis.

  19. Analysis of chromosome aberration data by hybrid-scale models

    International Nuclear Information System (INIS)

    Indrawati, Iwiq; Kumazawa, Shigeru

    2000-02-01

    This paper presents a new methodology for analyzing data of chromosome aberrations, which is useful to understand the characteristics of dose-response relationships and to construct the calibration curves for the biological dosimetry. The hybrid scale of linear and logarithmic scales brings a particular plotting paper, where the normal section paper, two types of semi-log papers and the log-log paper are continuously connected. The hybrid-hybrid plotting paper may contain nine kinds of linear relationships, and these are conveniently called hybrid scale models. One can systematically select the best-fit model among the nine models by among the conditions for a straight line of data points. A biological interpretation is possible with some hybrid-scale models. In this report, the hybrid scale models were applied to separately reported data on chromosome aberrations in human lymphocytes as well as on chromosome breaks in Tradescantia. The results proved that the proposed models fit the data better than the linear-quadratic model, despite the demerit of the increased number of model parameters. We showed that the hybrid-hybrid model (both variables of dose and response using the hybrid scale) provides the best-fit straight lines to be used as the reliable and readable calibration curves of chromosome aberrations. (author)

  20. Aberrant behavior and cognitive ability in preschool children

    Directory of Open Access Journals (Sweden)

    Bala Gustav

    2007-01-01

    Full Text Available The sample included 712 preschool boys and girls at the age of 4 to 7 years (mean 5.96 decimal years and standard deviation .96 from preschool institutions in Novi Sad, Sombor, Sremska Mitrovica and Bačka Palanka. Information concerning 36 indicators of aberrant behavior of the children were supplied by their parents, whereas their cognitive ability was tested by Raven’s progressive colored matrices. Based on factor analysis (promax method, four factors i.e. generators of aberrant behavior in children were singled out: aggression, anxiousness, dissociation, and hysteria, whose relations with cognitive functioning and age were also analyzed by factor analysis. Aberrant behavior and cognitive abilities show significant interrelatedness. Owing to orderly developed cognitive abilities, a child understands essence and reality of problems, realizes possibilities and manners of solving them, and succeeds in realizing successful psycho-social functioning. Developed cognitive abilities enable a child to recognize and understand her/his own reactions in different situations and develop manners of reacting, which leads to strengthening psycho-social safety and adapting behavior in accordance with her/his age and abilities.

  1. Effect of third-order aberrations on dynamic accommodation.

    Science.gov (United States)

    López-Gil, Norberto; Rucker, Frances J; Stark, Lawrence R; Badar, Mustanser; Borgovan, Theodore; Burke, Sean; Kruger, Philip B

    2007-03-01

    We investigate the potential for the third-order aberrations coma and trefoil to provide a signed cue to accommodation. It is first demonstrated theoretically (with some assumptions) that the point spread function is insensitive to the sign of spherical defocus in the presence of odd-order aberrations. In an experimental investigation, the accommodation response to a sinusoidal change in vergence (1-3D, 0.2Hz) of a monochromatic stimulus was obtained with a dynamic infrared optometer. Measurements were obtained in 10 young visually normal individuals with and without custom contact lenses that induced low and high values of r.m.s. trefoil (0.25, 1.03 microm) and coma (0.34, 0.94 microm). Despite variation between subjects, we did not find any statistically significant increase or decrease in the accommodative gain for low levels of trefoil and coma, although effects approached or reached significance for the high levels of trefoil and coma. Theoretical and experimental results indicate that the presence of Zernike third-order aberrations on the eye does not seem to play a crucial role in the dynamics of the accommodation response.

  2. Incidence of chromosomal aberrations and micronuclei in cave tour guides.

    Science.gov (United States)

    Bilban, M; Bilban-Jakopin, C; Vrhovec, S

    2001-01-01

    An analysis of structural chromosomal aberrations (SCA) and micronucleus tests (MN) were performed in 38 subjects, cave tour guides and in appropriate control group. The dominant type of chromosomal aberrations in tourist guides were chromosomal breaks (0.013 per cell) and acentric fragments (0.011 per cell). In the control group, these aberrations were present up to 0.008 on cells. Considering the analysed cells of the guides in total (33,556), the incidence of dicentric and rings range is below 0.0008 on cells, even though three dicentric and ring chromosoms were found already in the first 1000 in vitro metaphases of some guides. Only 0.0003 dicentrics and neither other translocations were found in control group (ambiental exposure). The incidence of micronuclei in cytokinesis blocked lymphocytes ranged from 12-32 per 500 CB cells in the cave tour guides and from 4-11 per 500 CB cells in control group. Measurements of radon and its daughters were performed at different locations in the cave. Annual doses from 40-60 mSv were estimated per 2000 work hours for cave guides. The changes found in the genome of somatic cells may be related to the exposure doses of radon and its daughters, although smoking should not be ignored.

  3. Molecular mechanisms involved in the production of chromosomal aberrations. I

    International Nuclear Information System (INIS)

    Natarajan, A.T.; Obe, G.

    1978-01-01

    Chinese hamster ovary cells (CHO) were X-irradiated in G2 stage of the cell cycle and immediately treated, in the presence of inactivated Sendai virus, with Neurospora endonuclease (E.C. 3.1.4.), an enzyme which is specific for cleaving single-stranded DNA. With this treatment, the frequencies of all types of chromosome aberrations increased when compared to X-irradiated controls. These results are interpreted as due to the conversion of some of the X-ray induced single-stranded DNA breaks into double-strand breaks by this enzyme. Similar enhancement due to this enzyme was found following treatment with methyl methanesulfonate (MMS) and bleomycin, but not following UV and mitomycin C. Addition of Micrococcus endonuclease and Neurospora endonuclease to the cells did not alter the frequencies of aberrations induced by UV. The introduction of enzymes with specific DNA-repair function offers possibilities to probe into the molecular events involved in the formation of structural chromosome aberrations induced by different classes of physical and chemical mutagens. (Auth.)

  4. Spherical aberration correction with threefold symmetric line currents.

    Science.gov (United States)

    Hoque, Shahedul; Ito, Hiroyuki; Nishi, Ryuji; Takaoka, Akio; Munro, Eric

    2016-02-01

    It has been shown that N-fold symmetric line current (henceforth denoted as N-SYLC) produces 2N-pole magnetic fields. In this paper, a threefold symmetric line current (N3-SYLC in short) is proposed for correcting 3rd order spherical aberration of round lenses. N3-SYLC can be realized without using magnetic materials, which makes it free of the problems of hysteresis, inhomogeneity and saturation. We investigate theoretically the basic properties of an N3-SYLC configuration which can in principle be realized by simple wires. By optimizing the parameters of a system with beam energy of 5.5keV, the required excitation current for correcting 3rd order spherical aberration coefficient of 400 mm is less than 1AT, and the residual higher order aberrations can be kept sufficiently small to obtain beam size of less than 1 nm for initial slopes up to 5 mrad. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Induction of chromosomal aberrations by neutron capture reactions

    International Nuclear Information System (INIS)

    Ikushima, Takaji

    1993-01-01

    Boron neutron capture reaction (B-NCR) has been practiced in the treatment of malignancies of the central nervous system and melanoma using a thermal neutron beam from the KUR. Because of the very large neutron absorption cross-section and high kinetic energy released, gadolinium (Gd-157) has been expected to be an another promising element for neutron capture therapy. The dose-response relationship was determined for the induction of chromosomal aberrations by neutron capture reactions by B-10 and Gd-157 in cultured mammalian cells. The cells were exposed to thermal neutron beam with and without B-10 enriched (97 atom %) boric acid or Gd-DTPA, and chromosome-type aberrations were analysed in the first metaphases following irradiation. The frequency of dicentrics and rings increased linearly with neutron fluence either in the presence or absence of B-10 boric acid, while the yield of chromosomal aberrations induced by Gd-NCR increased in a linear quadratic fashion as a function of dose as in γ-rayed cells. Survival curves for the cells exposed to thermal neutrons showed no shoulder irrespective of the loading of B-10, but Gd-NCR produced the survival curve with a small shoulder. The differential chromosomal response to B-NCR and Gd-NCR might reflect the difference in radiation quality generated from the two types of thermal neutron capture reaction. (J.P.N.)

  6. Chromosomal Aberrations in Humans Induced by Urban Air Pollution

    DEFF Research Database (Denmark)

    Knudsen, Lisbeth E.; Norppa, Hannu; Gamborg, Michael O.

    1999-01-01

    We have studied the influence of individual susceptibility factors on the genotoxic effects of urban air pollution in 106 nonsmoking bus drivers and 101 postal workers in the Copenhagen metropolitan area. We used the frequency of chromosomal aberrations in peripheral blood lymphocytes as a biomar......We have studied the influence of individual susceptibility factors on the genotoxic effects of urban air pollution in 106 nonsmoking bus drivers and 101 postal workers in the Copenhagen metropolitan area. We used the frequency of chromosomal aberrations in peripheral blood lymphocytes...... that long-term exposure to urban air pollution (with traffic as the main contributor) induces chromosome damage in human somatic cells. Low DNA repair capacity and GSTM1 and NAT2 variants associated with reduced detoxification ability increase susceptibility to such damage. The effect of the GSTM1 genotype......, which was observed only in the bus drivers, appears to be associated with air pollution, whereas the NAT2 genotype effect, which affected all subjects, may influence the individual response to some other common exposure or the baseline level of chromosomal aberrations....

  7. Origin of specific chromosome aberration in radiation-induced leukemia

    International Nuclear Information System (INIS)

    Ban, Nobuhiko; Kai, Michiaki; Masuno, Yoko

    2005-01-01

    The theme in the title is discussed from the four aspects of specific chromosome aberration (sAb) patterns in radiation-induced leukemia (RIL), possibility for radiation to induce the sAb in RIL, any evidence for participation of delayed aberration to form sAb and the proportion of such healthy humans as having the specifically rearranged genome. Data of sAb observed in leukemia of 25 A-bomb survivors and of 38 patients post radiotherapy of cancers give a rather common pattern. However, many inconsistent results are obtained for sAb in patients post radiotherapy, A-bomb survivors, residents living in radio-contaminated houses in Taipei, in vitro exposure, and Chernobyl residents. At present, any clear evidence is available neither for sAb derived from the delayed aberration nor for estimating the proportion with the specifically rearranged gene. As above, it is unlikely that radiation induces such a translocation abnormality as BCR-ABL specifically seen in leukemia, and this aspect will be important for studies on the genesis of RIL and its risk assessment. (S.I.)

  8. Dysphagia lusorium in elderly: A case report

    Science.gov (United States)

    Kantarceken, Bulent; Bulbuloglu, Ertan; Yuksel, Murvet; Cetinkaya, Ali

    2004-01-01

    AIM: Late unset of dysphagia due to vascular abnormalities is a rare condition. We aimed to present a case of right subclavian artery abnormalities caused dysphagia in the elderly. METHODS: A 68-year-old female was admitted with dysphagia seven months ago. Upper endoscopic procedures and routine examinations could not demonstrate any etiology. Multislice computed thorax tomography was performed for probable extra- esophagial lesions. RESULTS: Multislice computed thorax tomography showed right subclavian artery abnormality and esophagial compression with this aberrant artery. CONCLUSION: Causes of dysphagia in the elderly are commonly malignancies, strictures and/or motility disorders. If routine examinations and endoscopic procedures fail to show any etiology, rare vascular abnormalities can be considered in such patients. Multislice computed tomography is a usefull choice in such conditions. PMID:15285045

  9. Canine urothelial carcinoma: genomically aberrant and comparatively relevant.

    Science.gov (United States)

    Shapiro, S G; Raghunath, S; Williams, C; Motsinger-Reif, A A; Cullen, J M; Liu, T; Albertson, D; Ruvolo, M; Bergstrom Lucas, A; Jin, J; Knapp, D W; Schiffman, J D; Breen, M

    2015-06-01

    Urothelial carcinoma (UC), also referred to as transitional cell carcinoma (TCC), is the most common bladder malignancy in both human and canine populations. In human UC, numerous studies have demonstrated the prevalence of chromosomal imbalances. Although the histopathology of the disease is similar in both species, studies evaluating the genomic profile of canine UC are lacking, limiting the discovery of key comparative molecular markers associated with driving UC pathogenesis. In the present study, we evaluated 31 primary canine UC biopsies by oligonucleotide array comparative genomic hybridization (oaCGH). Results highlighted the presence of three highly recurrent numerical aberrations: gain of dog chromosome (CFA) 13 and 36 and loss of CFA 19. Regional gains of CFA 13 and 36 were present in 97 % and 84 % of cases, respectively, and losses on CFA 19 were present in 77 % of cases. Fluorescence in situ hybridization (FISH), using targeted bacterial artificial chromosome (BAC) clones and custom Agilent SureFISH probes, was performed to detect and quantify these regions in paraffin-embedded biopsy sections and urine-derived urothelial cells. The data indicate that these three aberrations are potentially diagnostic of UC. Comparison of our canine oaCGH data with that of 285 human cases identified a series of shared copy number aberrations. Using an informatics approach to interrogate the frequency of copy number aberrations across both species, we identified those that had the highest joint probability of association with UC. The most significant joint region contained the gene PABPC1, which should be considered further for its role in UC progression. In addition, cross-species filtering of genome-wide copy number data highlighted several genes as high-profile candidates for further analysis, including CDKN2A, S100A8/9, and LRP1B. We propose that these common aberrations are indicative of an evolutionarily conserved mechanism of pathogenesis and harbor genes

  10. Upper limb artery segmental occlusions due to chronic use of ergotamine combined with itraconazole, treated by thrombolysis

    Directory of Open Access Journals (Sweden)

    Nodari Franco

    2011-08-01

    Full Text Available Abstract Background The ergotamine tartrate associated with certain categories of drugs can lead to critical ischemia of the extremities. Discontinuation of taking ergotamine is usually sufficient for the total regression of ischemia, but in some cases it could be necessary thrombolytic and anticoagulant therapy to avoid amputation. Case report A woman of 62 years presented with a severe pain left forearm appeared 10 days ago, with a worsening trend. The same symptoms appeared after 5 days also in the right forearm. Physical examination showed the right arm slightly hypothermic, with radial reduced pulse in presence of reduced sensitivity. The left arm was frankly hypothermic, pulse less on radial and with an ulnar humeral reduced pulse, associated to a decreased sensitivity and motility. Clinical history shows a chronic headache for which the patient took a daily basis for years Cafergot suppository (equivalent to 3.2 mg of ergotamine. From about ten days had begun therapy with itraconazole for vaginal candidiasis. The Color-Doppler ultrasound shown arterial thrombosis of the upper limbs (humeral and radial bilateral, with minimal residual flow to the right and no signal on the humeral and radial left artery. Results Angiography revealed progressive reduction in size of the axillary artery and right humeral artery stenosis with right segmental occlusions and multiple hypertrophic collateral circulations at the elbow joint. At the level of the right forearm was recognizable only the radial artery, decreased in size. Does not recognize the ulnar, interosseous artery was thin. To the left showed progressive reduction in size of the distal subclavian and humeral artery, determined by multiple segmental steno-occlusion with collateral vessels serving only a thin hypotrophic interosseous artery. Arteriographic findings were compatible with systemic drug-induced disease. The immediate implementation of thrombolysis, continued for 26 hours, with

  11. Mechanical design in arteries.

    Science.gov (United States)

    Shadwick, R E

    1999-12-01

    The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

  12. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  13. Endovascular uterine artery interventions

    Directory of Open Access Journals (Sweden)

    Chandan J Das

    2017-01-01

    Full Text Available Percutaneous vascular embolization plays an important role in the management of various gynecologic and obstetric abnormalities. Transcatheter embolization is a minimally invasive alternative procedure to surgery with reduced morbidity and mortality, and preserves the patient's future fertility potential. The clinical indications for transcatheter embolization are much broader and include many benign gynecologic conditions, such as fibroid, adenomyosis, and arteriovenous malformations (AVMs, as well as intractable bleeding due to inoperable advanced-stage malignancies. The most well-known and well-studied indication is uterine fibroid embolization. Uterine artery embolization (UAE may be performed to prevent or treat bleeding associated with various obstetric conditions, including postpartum hemorrhage (PPH, placental implantation abnormality, and ectopic pregnancy. Embolization of the uterine artery or the internal iliac artery also may be performed to control pelvic bleeding due to coagulopathy or iatrogenic injury. This article discusses these gynecologic and obstetric indications for transcatheter embolization and reviews procedural techniques and outcomes.

  14. Analysis of the population at high risk of stroke detected with carotid artery ultrasonography in Tianjin urban communities

    Directory of Open Access Journals (Sweden)

    Wei YUE

    2015-04-01

    Full Text Available Objective To investigate the features of carotid atherosclerosis in a population at high risk of stroke in urban communities of Tianjin, so as to provide inspiration for carotid ultrasonography to play a greater role in the prevention and control of stroke.  Methods A total of 956 residents at high risk of stroke were selected from 4 urban communities in Tianjin using cluster random sampling method. Doppler ultrasound screening was performed in bilateral common carotid artery (CCA, internal carotid artery (ICA, external carotid artery (ECA, vertebral artery (VA, subclavian artery (SCA and innominate artery of the population. The intima-media thickness (IMT, atherosclerotic plaque formation and its location and size, vascular stenosis or occlusion, and flow spectrum were detected. The results and features of carotid ultrasound screening were analyzed and compared among different gender and age groups.  Results 1 The detection rate of carotid atherosclerosis was 71.55% (684/956, and the detection rate in males was significantly higher than that in females (79.08% vs 65.87%; χ2 = 20.067, P = 0.000. 2 Among the population with carotid atherosclerosis, the most common manifestation was the formation of atherosclerotic plaques (81.58%, 558/684, secondly intima-media thickening (13.01%, 89/684, followed by moderate to severe stenosis or occlusion (5.41%, 37/684. The proportion of intima-media thickening in males was lower than that in females (7.08% vs 18.38%; χ2 = 19.269, P = 0.000. The proportion of carotid atherosclerotic plaque formation in males was higher than that in females (86.46% vs 77.16%; χ2 = 9.824, P = 0.002. The median rating of carotid atherosclerosis was 1.79, with males higher than females [1.98 (0.70, 3.26 vs 1.52 (0.20, 2.84; Z = 2.304, P = 0.042]. The site of plaque formation was most commonly located in carotid bulb (36.61%, secondly SCA (22.18%. Of the type of carotid stenosis, ICA stenosis was detected in 30 cases, VA

  15. Cervicocephalic arterial dissection

    International Nuclear Information System (INIS)

    Suyama, Kazuhiko; Hayashi, Kentaro; Nagata, Izumi

    2008-01-01

    The authors review the clinical and neuroradiological features of cervicocephalic arterial dissection, which is occasionally seen in young adults, with special reference to the differences in the region of occurrence of these lesions between patients in Western countries and Japan. In Western countries, the cervical internal carotid artery is the most common site of occurrence of these lesions; however, in Japan, these lesions have been frequently reported to occure in the intracranial vertebral artery. Most clinical manifestations of cervical arterial dissection are non-hemorrhagic events such as headaches associated with arterial dissection or cerebral ischemia caused by a distal embolism following thrombus formation in the cervical lesion. On the other hand, a subarachnoid hemorrhage and cerebral infarction are frequently observed in intracranial arterial dissections. Non-invasive procedures, including MR imaging, are useful for demonstrating characteristic features of this condition such as the presence of an intimal flap or a double lumen, and for monitoring the chronological changes in the lesions, which may regress spontaneously. Since the pathological mechanisms underlying the progression and/or the regression of this condition are still unknown, the clinical evidence indicating the optimal therapeutic strategies has not yet been reported. Nevertheless, conservative therapy, including antithrombotic treatment, is widely used for the treatment of non-hemorrhagic lesions, which generally results in good clinical outcomes. Further, surgical intervention is essential for the treatment of lesions with a subarachnoid hemorrhage to prevent fatal rebleeding, and it is also required for the treatment of certain non-hemorrhagic lesions. Recent advancements in surgical procedures, especially endovascular treatments, may therefore be helpful in the management of similar complicated vascular conditions. (author)

  16. Arterial disease after radiotherapy

    International Nuclear Information System (INIS)

    Bigot, J.M.; Mathieu, D.; Reizine, D.

    1983-01-01

    Disease of the large arterial vessels is a relatively unknown complication of radiotherapy. However, it should be considered in the same manner as the other complications of irradiation when a tumour recurrence is suspected. The experimental studies of Kirkpatrick and Konings, demonstrating the synergy between irradiation and hypercholesterolemia in the precocity and gravity of vascular complications are recalled. The different localisations reported in the litterature are discussed: coronary, pulmonary, thoracic aorta, supra aortic, renal, digestive and ilio-femoral arteries. Finally, the difficulty of diagnosis of post-radiotherapy without clinical, radiological or anatomopathological confirmation, is underlined [fr

  17. Renal artery stenosis.

    Science.gov (United States)

    Tafur-Soto, Jose David; White, Christopher J

    2015-02-01

    Atherosclerotic renal artery stenosis (RAS) is the single largest cause of secondary hypertension; it is associated with progressive renal insufficiency and causes cardiovascular complications such as refractory heart failure and flash pulmonary edema. Medical therapy, including risk factor modification, renin-angiotensin-aldosterone system antagonists, lipid-lowering agents, and antiplatelet therapy, is advised in all patients. Patients with uncontrolled renovascular hypertension despite optimal medical therapy, ischemic nephropathy, and cardiac destabilization syndromes who have severe RAS are likely to benefit from renal artery revascularization. Screening for RAS can be done with Doppler ultrasonography, CT angiography, and magnetic resonance angiography. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  19. Anatomy of the transverse colon revisited with respect to complete mesocolic excision and possible pathways of aberrant lymphatic tumor spread.

    Science.gov (United States)

    Stelzner, Sigmar; Hohenberger, Werner; Weber, Klaus; West, Nicholas P; Witzigmann, Helmut; Wedel, Thilo

    2016-02-01

    Although lymph node metastases to pancreatic and gastroepiploic lymph node stations in transverse colon cancer have been described, the mode of lymphatic spread in this area remains unclear. This study was undertaken to describe possible pathways of aberrant lymphatic spread in the complex anatomic area of the proximal superior mesenteric artery and vein, the greater omentum, and the lower pancreatic border. Abdominal specimens obtained from four cadaveric donors were dissected according to the principles of complete mesocolic excision. The vascular architecture of the transverse colon was scrutinized in search of possible pathways of lymphatic spread to the pancreatic and gastroepiploic lymph nodes. Vascular connections between the transverse colon and the greater omentum at the level of both the hepatic and the splenic flexures could be identified. In addition, small vessels running from the transverse mesocolon to the lower pancreatic border in the area between the middle colic artery and the inferior mesenteric vein were demonstrated. Moreover, venous tributaries to the gastrocolic trunk could be exposed to highlight its surgical importance as a guiding structure for complete mesocolic excision. The technical feasibility to clearly separate embryologic compartments by predefined tissue planes in complete mesocolic excision was confirmed. However, the vicinity of all three endodermal intestinal segments (foregut, midgut, and hindgut) obviously gives way to vascular connections that might serve as potential pathways for lymphatic metastatic spread of transverse colon cancer.

  20. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    Science.gov (United States)

    Zhao, Hao-Xin; Xu, Bing; Xue, Li-Xia; Dai, Yun; Liu, Qian; Rao, Xue-Jun

    2008-04-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.