WorldWideScience

Sample records for abdominal phase-contrast blood

  1. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  2. Cine phase-contrast MR to assess portal blood flow in a 10-year-old girl with abdominal aortic coarctation: a case report

    International Nuclear Information System (INIS)

    Clark, T.W.I.; Culham, J.A.G.

    1998-01-01

    We report the case of a 10-year-old girl with repaired abdominal aortic coarctation in whom chronic mesenteric ischemia was clinically suspected. Cine phase-contrast magnetic resonance (MR) was used to determine the difference between fasting and postprandial portal blood flow. Fasting flow rates in the portal vein were normal. After a meal, blood flow in the portal vein increased 226 % over the fasting state, showing normal augmentation. To the best of our knowledge, this is the first application of this technique to a pediatric setting. (orig.)

  3. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain......-gauge plethysmography was used to measure the adipose tissue and forearm blood flow, respectively. Ultrasound signal intensity of the first plateau phases was 27 ± dB in the abdominal subcutaneous adipose tissue and 18 ± 2 dB (P

  4. When the non-contrast-enhanced phase is unnecessary in abdominal computed tomography scans? A retrospective analysis of 244 cases

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Danilo Manuel Cerqueira; Salvadori, Priscila Silveira; Monjardim, Rodrigo da Fonseca; Bretas, Elisa Almeida Sathler; Torres, Lucas Rios; Caldana, Rogerio Pedreschi; Shigueoka, David Carlos; Medeiros, Regina Bitelli; D' ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2013-06-15

    Objective: to evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis. (author)

  5. Depiction of blood vessels by x-ray phase contrast

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [School of Engineering, University of Tokyo, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Institute of Clinical Medicine, University of Tsukuba, Tsukuba, Ibaraki (Japan)

    2001-04-01

    Blood vessels in livers of a mouse and a rat were depicted by phase-contrast x-ray imaging with an x-ray interferometer without using contrast agents. X-ray interference patterns were converted to image mapping x-ray phase shift caused by the livers using the technique of phase-shifting x-ray interferometry. The arteries and veins to and from the livers were tied before excision in order to prevent blood from flowing out of the liver. The x-ray phase shift caused by blood was substantially different from that caused by other soft sues, and consequently trees of blood vessels were revealed in the images. Vessels of diameter smaller than 0.1 mm were detected. This result suggests new possibilities for investigating vascular systems. (author)

  6. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  7. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    International Nuclear Information System (INIS)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D'Ippolito, Giuseppe

    2013-01-01

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  8. Automatic blood vessel based-liver segmentation using the portal phase abdominal CT

    Science.gov (United States)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2018-02-01

    Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

  9. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D. [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang [Changhai Hospital, Department of Radiology, Shanghai (China); Saloner, David [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Radiology Service, VA Medical Center, San Francisco, CA (United States)

    2017-05-15

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T{sub 1}-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT{sub r} = signal{sub ILT}/signal{sub Muscle}) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  10. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    International Nuclear Information System (INIS)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D.; Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang; Saloner, David

    2017-01-01

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T_1-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT_r = signal_I_L_T/signal_M_u_s_c_l_e) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  11. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  12. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    Science.gov (United States)

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

  13. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  14. Evaluation of oral abdominal contrast agent containing ferric ammonium citrate

    International Nuclear Information System (INIS)

    Shiga, Toshiko; Kawamura, Yasutaka; Iwasaki, Toshiko

    1991-01-01

    We evaluated the effectiveness of oral MRI contrast agent containing ferric ammonium citrate. Twenty patients were arbitrarily divided into 2 groups according to the given dose of 100 and 200 mg Fe of oral MRI contrast agent. MRI was performed before and immediately after ingesting 300 ml solution of oral MRI contrast agent using a 1.5 T superconducting system (GE: Signa). Each dose of 100 and 200 mg Fe of oral MRI contrast agent produced sufficient enhancement of gastrointestinal tract, enough to make clear the pancreatic contour and porta hepatis. There was no significant change in blood and urine analysis observed after taking oral MRI contrast agent. The use of ferric ammonium citrate as an oral MRI contrast agent seems to add valuable information in performing upper abdominal MRI imaging. (author)

  15. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  16. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Keum Soo; Choi, Sun Seob; Lee, Young Il [Dong-A Univ., College of Medicine, Busan (Korea, Republic of)

    2001-12-01

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628{+-}68 (range, 517 to 779) ml/min and 612{+-}79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow.

  17. Quantitative measurement of portal blood flow by magnetic resonance phase contrast. Comparative study of flow phantom and Doppler ultrasound in vivo

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Hamazaki, Keisuke; Takeda, Yoshihiro; Hiraki, Yoshio.

    1994-01-01

    A non-invasive method for measuring portal blood flow by magnetic resonance (MR) phase contrast was evaluated in a flow phantom and 20 healthy volunteers. In a flow phantom study, the flow volumes and mean flow velocities measured by MR phase contrast showed close correlations with those measured by electromagnetic flow-metry. In 20 healthy volunteers, the cross-sectional areas, flow volumes and mean flow velocities measured by MR phase contrast correlated well with those measured by the Doppler ultrasound method. Portal blood flow averaged during the imaging time could be measured under natural breathing conditions by using a large number of acquisitions without the limitations imposed on the Doppler ultrasound method. MR phase contrast is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  18. O valor da fase sem contraste na tomografia computadorizada do abdome The role of the unenhanced phase in the routine abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Ana Paula Klautau Leite

    2008-10-01

    Full Text Available OBJETIVO: Determinar o valor agregado da fase sem meio de contraste da tomografia computadorizada do abdome em pacientes sem diagnóstico determinado ou em estadiamento tumoral. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 100 pacientes consecutivos submetidos a tomografia computadorizada abdominal sem e com meio de contraste intravenoso. Dois examinadores avaliaram todos os exames, procurando estabelecer, através da fase com meio de contraste intravenoso (primeira análise e posteriormente através da fase sem contraste (segunda análise, o diagnóstico principal e os secundários em função da indicação clínica do exame. Mediu-se a freqüência de mudança diagnóstica decorrente da análise combinada das fases pré- e pós-contraste intravenoso. Casos que tiveram mudança diagnóstica foram avaliados por especialistas clínicos para determinar se implicaria mudanças de conduta. RESULTADOS: Diagnósticos principal e secundário foram modificados em 1 e 18 casos, respectivamente (p = 1,000; p = 0,143. Os diagnósticos modificados foram: esteatose, definição de nódulo em adrenal, nefrolitíase, classificação de cistos renais e calcificação hepática. Nos casos em que a fase sem contraste modificou o diagnóstico, os especialistas mudaram sua conduta em 14/19 (73% dos pacientes (p = 0,038. CONCLUSÃO: A fase sem contraste não modificou significativamente o diagnóstico principal ou secundário. Porém, as mudanças nos diagnósticos secundários influenciaram na conduta adotada pelos especialistas.OBJECTIVE: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. MATERIALS AND METHODS: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast-enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase

  19. Measurement of renal blood flow by phase-contrast magnetic resonance imaging during septic acute kidney injury: a pilot investigation.

    Science.gov (United States)

    Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo

    2012-06-01

    In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in

  20. Dynamic and delayed contrast enhancement in upper abdominal MRI studies: Comparison of gadoxetic acid and gadobutrol

    Energy Technology Data Exchange (ETDEWEB)

    Zizka, Jan [Department of Radiology, Charles University Hospital, Sokolska 581, CZ-500 05 Hradec Kralove (Czech Republic)]. E-mail: zizka@fnhk.cz; Klzo, Ludovit [Department of Radiology, Charles University Hospital, Sokolska 581, CZ-500 05 Hradec Kralove (Czech Republic); Ferda, Jiri [Department of Radiology, Charles University Hospital, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Mrklovsky, Milan [Department of Radiology and Imaging Centre Pardubice, Regional Hospital, Kyjevska 44, CZ-530 01 Pardubice (Czech Republic); Bukac, Josef [Department of Biophysics, Medical Faculty, Charles University, Simkova 870, CZ-500 38 Hradec Kralove (Czech Republic)

    2007-05-15

    Objective: To prospectively compare contrast properties of extracelullar (gadobutrol) and hepatospecific (gadoxetic acid) contrast agents in upper abdominal MRI studies. Materials and methods: Standardized (0.1 ml/kg) dose of gadobutrol (56 subjects) and gadoxetic acid (51 subjects) was administered intravenously by MRI-compatible injector at 2 ml/s, followed by 20 ml saline flush. MR signal intensity changes (SIC) between precontrast scans and arterial phase, portal venous phase, equilibrium, and delayed scans at 10 and 20 min were measured in abdominal aorta, portal vein, common bile duct, liver, and spleen. Mean SIC values for gadobutrol and gadoxetic acid were compared by a two-sample t-test with p-value <0.05 considered significant. Results: In abdominal aorta, the mean SIC in the arterial phase did not significantly differ between gadobutrol (330%) and gadoxetic acid (295%). In portal vein, the mean SIC in the portal venous phase significantly differed between gadobutrol (267%) and gadoxetic acid (176%). Liver parenchyma enhancement was significantly higher for gadobutrol than for gadoxetic acid in both arterial phase (28 versus 13%) and portal venous phase (81 versus 46%). On the contrary, gadobutrol reached significantly lower mean SIC in the liver on delayed scans at 10 min (47 versus 59%) and 20 min (40 versus 67%), as well as in common bile duct at 10 min (54 versus 133%) and 20 min (57 versus 457%), respectively. In the spleen, mean SIC for gadobutrol was significantly higher at all phases. Conclusion: Gadobutrol showed superior enhancement of upper abdominal structures in the dynamic phases whereas gadoxetic acid showed better enhancement of the hepatobiliary structures on delayed scans.

  1. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  2. What is the real role of the equilibrium phase in abdominal computed tomography?

    Energy Technology Data Exchange (ETDEWEB)

    Salvadori, Priscila Silveira [Universidade Federal de Sao Paulo (EPM-Unifesp), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Galvao, Breno Vitor Tomaz; Monjardim, Rodrigo da Fonseca; Bretas, Elisa Almeida Sathler; Rios, Lucas Torres; Shigueoka, David Carlos; Caldana, Rogerio Pedreschi; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM-Unifesp), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Department of Diagnostic Imaging

    2013-03-15

    Objective: To evaluate the role of the equilibrium phase in abdominal computed tomography. Materials and Methods: A retrospective, cross-sectional, observational study reviewed 219 consecutive contrast-enhanced abdominal computed tomography images acquired in a three-month period, for different clinical indications. For each study, two reports were issued - one based on the initial analysis of non-contrast-enhanced, arterial and portal phases only (first analysis), and a second reading of these phases added to the equilibrium phase (second analysis). At the end of both readings, differences between primary and secondary diagnoses were pointed out and recorded, in order to measure the impact of suppressing the equilibrium phase on the clinical outcome for each of the patients. The extension of the exact Fisher's test was utilized to evaluate the changes in the primary diagnosis (p < 0.05 as significant). Results: Among the 219 cases reviewed, the absence of the equilibrium phase determined change in the primary diagnosis in only one case (0.46%; p > 0.999). As regards secondary diagnoses, changes after the second analysis were observed in five cases (2.3%). Conclusion: For clinical scenarios such as cancer staging, acute abdomen and investigation for abdominal collections, the equilibrium phase is dispensable and does not offer any significant diagnostic contribution. (author)

  3. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  4. Three-dimensional contrast-enhanced MRI using an intravascular contrast agent for detection of traumatic intra-abdominal hemorrhage and abdominal parenchymal injuries: an experimental study

    International Nuclear Information System (INIS)

    Weishaupt, D.; Ruehm, S.G.; Patak, M.A.; Schmidt, M.; Debatin, J.F.; Hetzer, F.H.

    2000-01-01

    The aim of this study was to compare the performance of 3D MRI in conjunction with an intravascular contrast agent to spiral contrast-enhanced CT, regarding the detection of abdominal parenchymal injuries as well as peritoneal hemorrhage in an animal model. Liver and kidney injuries were created surgically in six female pigs under general anesthesia. All pigs underwent contrast-enhanced spiral CT and 3D MR imaging following administration of an intravascular contrast agent (NC100150 Injection). Two readers rated their confidence independently on MR and CT data sets using a five-point scale for the presence of organ injury and hemoperitoneum. Autopsy findings served as standard of reference. Sensitivity and specificity for MR in detecting hepatic and renal injuries as well as hemoperitoneum was 100 %. Computed tomography was less accurate with sensitivity and specificity values of 90 and 94 %, respectively. Receiver operating characteristics (ROC) analysis revealed a higher confidence when interpretation was based on MR images. In an animal model 3D MR imaging in conjunction with an intravascular contrast agent proved highly accurate in detecting and localizing parenchymal injuries to the upper abdomen as well as in detecting intraperitoneal blood collections. (orig.)

  5. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  6. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  7. The role of the unenhanced phase in the routine abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Ana Paula Klautau; Mattos, Leandro Accardo de; Pinto, Gustavo Alfredo Duarte Henriques; Scaciota, Andrea Puchnick; Lederman, Henrique Manoel; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: scoposl@uol.com.br; Franco, Rita Maria Aparecida Monteiro Moura [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroclinica; Andreoni, Cassio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Urologia

    2008-09-15

    Objective: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. Materials and methods: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase (first analysis) and, later, in the unenhanced phase (second analysis) in an attempt to establish the primary and secondary diagnoses as a function of the clinical indication for the study. The frequency of changes in the diagnoses resulting from a combined analysis of the images in the pre- and post-contrast phases was evaluated. Cases with changes in the diagnosis were reviewed by clinical specialists for determining possible changes in the therapeutic approach. Results: Primary and secondary diagnoses were changed in respectively 1 and 18 cases (p = 1.000; p = 0.143) as follows: steatosis, adrenal nodules, nephrolithiasis, renal cysts and hepatic calcification. In the cases where the unenhanced phase changed the diagnosis, the specialists changed the therapeutic approach in 14 of the 19 patients (73%) (p = 0.038). Conclusion: No significant change was observed in the primary or secondary diagnosis as a result of the findings in the unenhanced phase. However, changes in secondary diagnoses affected the therapeutic approach adopted by the specialists. (author)

  8. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  9. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  10. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  11. Wearing an abdominal belt increases diastolic blood pressure.

    Science.gov (United States)

    Rafacz, W; McGill, S M

    1996-09-01

    The purpose of this study was to determine the effect of wearing an abdominal belt on blood pressure (systolic and diastolic) and heart rate during a variety of tasks. The belt was typical of the elastic type with suspenders and Velcro tabs for cinching the belt snug. The tasks performed included sitting at rest, sitting with the torso inclined forward at 45 degrees, standing with the torso inclined forward at 45 degrees (with and without holding an 11-kg weight), a trunk axial rotation task, and squat lifting. Blood pressure was monitored noninvasively with a FINAPRES blood pressure monitor. Twenty healthy men performed each task with and without the abdominal belt. Although no significant increases in mean systolic blood pressure or heart rate were found, there was a significant increase in diastolic blood pressure in all conditions. All people considering wearing an abdominal belt should also consider the risks and liability associated with the additional cardiovascular load, particularly heart attack and stroke.

  12. Phase contrast MRI assessment of pedal blood flow

    International Nuclear Information System (INIS)

    Debatin, J.F.; Dalman, R.; Herfkens, R.J.; Harris, E.J.; Pelc, N.J.

    1995-01-01

    This study attempts to evaluate the reliability of cine phase contrast (PC) flow measurements in the assessment of normal pedal blood flow and quantitation of revascularisation-induced flow changes in patients with end-stage peripheral vascular occlusive disease (PVOD). Oblique axial cine-PC acquisitions were obtained on a 1.5 T MRI system at the level of the talotibial joints in 8 normal subjects on four separate occasions. Subsequently 8 patients with end-stage PVOD were examined before and after surgical revascularisation (bilateral, n = 2; unilateral, n = 6). Measured flow in the trifurcation vessels was highly variable among normal subjects. Total pedal flow ranged from 32 to 183 ml/min (mean 91 ml/min) and was significantly different between the subjects evaluated (P < 0.0001). Measurements in the same subject over time were considerably less variable (P < 0.005). Normal arterial flow patterns were consistently triphasic; those in patients with PVOD were either mono- or biphasic. Pedal flow measured by cine-PC in patients was reduced compared with normal subjects (mean 38.3 ml/min). Flow was slower in symptomatic limbs (26.7 ml/min) compared with asymptomatic ones (48.9 ml/min). Flow increases in revascularised limbs (mean 315%) were significantly different from those observed in non-affected limbs (P < 0.005). The ability to quantitate pedal blood flow and subsequent revascularisation-induced flow increases appears promising for the identification of optimal treatment options and monitoring of treatment results. (orig.)

  13. Local blood-brain barrier penetration following systemic contrast medium administration

    International Nuclear Information System (INIS)

    Utz, R.; Ekholm, S.E.; Isaac, L.; Sands, M.; Fonte, D.

    1988-01-01

    The present study was initiated by a severe complication in a patient with renal dysfunction who developed cortical blindness and weakness of her left extremities 30 hours following renal and abdominal angiography. To evaluate the impact of prolonged high serum concentrations of contrast medium (CM) this clinical situation was simulated in a laboratory model using sheep with elevated serum levels of contrast medium maintained for 48 hours. The experimental data did not support the theory that the prolonged exposure to high circulating levels of contrast medium (4 ml/kg body weight of meglumine diatrizoate 60%) is sufficient alone to cause penetration of the blood-brain barrier. (orig.)

  14. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease.

    Science.gov (United States)

    Spithoven, E M; Meijer, E; Borns, C; Boertien, W E; Gaillard, C A J M; Kappert, P; Greuter, M J W; van der Jagt, E; Vart, P; de Jong, P E; Gansevoort, R T

    2016-03-01

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBFMRI) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. First, we validated RBFMRI measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBFMRI. After validation, we measured RBFMRI in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBFMRI and RBF measured by continuous hippuran infusion. The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBFMRI measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBFMRI compared to RBFHip, whereas in subjects with lower eGFRs, this was significantly less for RBFMRI. Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. Renal blood flow (RBF) can be accurately measured by phase-contrast MRI in ADPKD patients. RBF measured by phase-contrast is associated with ADPKD disease severity. RBF measurement by phase-contrast MRI may be less feasible in patients with an impaired eGFR.

  15. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ... preferred for evaluation of acute abdominal conditions in babies, such as vomiting or blood in stool. For ...

  17. Analysis of blood flow dynamics in the abdominal aorta based on MR images

    International Nuclear Information System (INIS)

    Shimamura, Koumei; Tsubota, Kenichi; Ryu, Hiroshi; Sugimoto, Koichi; Haneishi, Hideaki

    2010-01-01

    Images of the abdominal aorta including peri-renal artery by PCMRA (phase contrast magnetic resonance angiography) were analyzed to calculate WSS (wall shear stress) and its OSI (oscillatory shear index) in order to visually elucidate the cause of aneurysm formation. PCMRA was conducted for acquisitions of vascular morphology in one cardiac cycle of a healthy male 30s with cardiac gating, and of blood flow rates from 3 directions. Images were median-filtered to reduce noises and regions of interest of rectangular parallelepiped were defined to involve the aorta. WSS, the parameter representing the intensity of friction stress to the vessel wall of blood flow, and OSI, the degree of oscillatory WSS change, were calculated firstly by the reported Snake model for the vessel morphology and then by applying its local information to blood flow rate information from 3 directions. Color-displayed images revealed that both WSS and OS were high at the highest incidental region of aortic aneurysm formation around the peri-renal artery. The finding was in good agreement with the result of computed bio-dynamic simulation that the strong WSS by elevated swirling of blood flow is generated at the region. Thus WSS and OS can be significant factors of aneurismal formation, which should be further confirmed from aspects of increased case number and precision. (T.T.)

  18. In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo

    International Nuclear Information System (INIS)

    Li Beilei; Xu Min; Shi Hongcheng; Chen Shaoliang; Wu Weizhong; Peng Guanyun; Zhang Xi; Peng Yifeng

    2012-01-01

    Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors. Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method. Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility. Barium sulfate and physiological saline were used as contrast agents for the blood vessels. Blood vessels of <Φ20 μm could be detected by replacing resident blood with physiological saline or barium sulfate. An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image. It is demonstrated that selective angiography based on phase contrast X-ray imaging, with a physiological material of low Z elements (such as saline) being the contrast agent, is a viable imaging strategy. Further efforts will be focused on using the technique to image tumor angiogenesis. (authors)

  19. Magnetic Resonance angiography with bolus contrast agent in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Di Cesare, E.; Cerone, G.; Giordano, A.V.; Marsili, L.; Barile, A.; Michelini, O.; Masciocchi, C.; Spartera, C.

    2000-01-01

    Purpose of this paper is to investigate the potentials of 3D breath-hold contrast-enhanced Magnetic Resonance Angiography (MRA) in the diagnosis, follow-up and treatment planning of abdominal aortic aneurysms. Twenty-four patients with infrarenal aortic aneurysm underwent MRA. It was used a 1.5 T unit (GE Horizon, Echospeed 8.2), a phased array surface coil and 3D Fast SPGR T1-weighted sequences acquired on the coronal plane during patient breath-hold and after contrast agent i.v. administration. A bolus-test was done before angiography to optimize imaging delay time. After 3D MRA a Fast-SPGR T1-weighted sequence was acquired on the axial plane. The 3D MRA source images were processed with the MIP algorithm. Qualitative and quantitative analyses were carried out. Helical CT was performed in 6 cases and DSA in 7 cases. Surgery was the reference standard in 15 patients. MRA depicted aneurysm thrombosis in 22 cases, carrefour involvement in 18 cases and iliac arteries involvement in 3 cases. Accessory renal arteries were shown in 4 cases; iliac artery stenosis was associated in 5 cases. There was agreement between MR and Helical CT and DSA findings: surgery confirmed MRA results in 15/15 cases. 3D contrast-enhanced MRA can be considered the method of choice in the follow-up and treatment planning of abdominal aortic aneurysms, because it provides both angiographic and tomographic images: this allows to obtain more information, noninvasively and without the use of ionizing radiations [it

  20. Effects of anabolic steroids on acute phase responses in intra-abdominal sepsis

    Directory of Open Access Journals (Sweden)

    K. Mealy

    1997-01-01

    Full Text Available The acute phase response is an important adaptive response to sepsis and injury. As anabolic steroids increase protein synthesis we postulated that these agents might also increase hepatic acute phase protein synthesis. Male Wistar rats were pretreated with testosterone or danazol for 48 h prior to caecal ligation and puncture (CLP. Thirty-six h following surgery the animals were killed and blood taken for full blood count, total protein, albumin, α, β and γ globulin fractions on serum electrophoresis, complement C3 and transferrin levels. Danazol increased the α1, α2 and β1 globulin serum protein fractions in comparison with no surgery and CLP alone groups. These results indicate that danazol increases plasma acute phase proteins, as measured by electrophoresis, in this model of intra-abdominal sepsis.

  1. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors

    OpenAIRE

    Tong Yu; Jun Gao; Zhi-Min Liu; Qi-Feng Zhang; Yong Liu; Ling Jiang; Yun Peng

    2017-01-01

    Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors...

  2. Generalized phase contrast:

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast...

  3. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.

    Science.gov (United States)

    Lüdemann, Lutz; Nafz, Benno; Elsner, Franz; Grosse-Siestrup, Christian; Meissler, Michael; Kaufels, Nicola; Rehbein, Hagen; Persson, Pontus B; Michaely, Henrik J; Lengsfeld, Philipp; Voth, Matthias; Gutberlet, Matthias

    2009-03-01

    To evaluate for the first time in an animal model the possibility of absolute regional quantification of renal medullary and cortical perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a blood pool contrast agent. A total of 18 adult female pigs (age, 16-22 weeks; body weight, 45-65 kg; no dietary restrictions) were investigated by DCE-MRI. Absolute renal blood flow (RBF) measured by an ultrasound transit time flow probe around the renal vein was used as the standard of reference. An inflatable stainless cuff placed around the renal artery near its origin from the abdominal aorta was used to reduce RBF to 60%, 40%, and 20% of the baseline flow. The last measurement was performed with the cuff fully reopened. Absolute RBF values during these 4 perfusion states were compared with the results of DCE-MRI performed on a 1.5-T scanner with an 8-channel phased-array surface coil. All scans were acquired in breath-hold technique in the coronal plane using a field of view of 460 mm.Each dynamic scan commenced with a set of five 3D T1-weighted gradient echo sequences with different flip angles (alpha = 2 degrees, 5 degrees, 10 degrees, 20 degrees, 30 degrees): TE, 0.88 milliseconds; TR, 2.65 milliseconds; slice thickness, 8.8 mm for 4 slices; acquisition matrix, 128 x 128; and acquisitions, 4. These data served to calculate 3D intrinsic longitudinal relaxation rate maps (R10) and magnetization (M0). Immediately after these images, the dynamic 3D T1-weighted gradient echo images were acquired with the same parameters and a constant alpha = 30 degrees, half Fourier, 1 acquisition, 64 frames, a time interval of 1.65 seconds between each frame, and a total duration of 105.6. Three milliliters of an albumin-binding blood pool contrast agent (0.25 mmol/mL gadofosveset trisodium, Vasovist, Bayer Schering Pharma AG, Berlin, Germany) was injected at a rate of 3 mL/s. Perfusion was calculated using the arterial input function from the aorta, which was

  4. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease

    NARCIS (Netherlands)

    Spithoven, Edwin M.; Meijer, E.; Borns, C.; Boertien, W. E.; Gaillard, C. A. J. M.; Kappert, P.; Greuter, Marcel J W; van der Jagt, E.; Vart, P.; de Jong, P. E.; Gansevoort, Ron T.

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBFMRI) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR)

  5. Initial studies of synchrotron radiation phase-contrast imaging in the field of medicine

    International Nuclear Information System (INIS)

    Chen Shaoliang; Zhang Xi; Peng Yifeng; Li Beilei; Cheng Aiping; Zhu Peiping; Yuan Xiqing; Huang Wanxia

    2010-01-01

    Recently,research on using X-ray phase information in medicine has been growing remarkably fast. Phase-contrast imaging with synchrotron radiation can reveal inner soft tissues such as tendons, cartilage, ligaments, adipose tissue, vessels and nerves without a contrast agent. We have visualized the liver, bile duct, lung, kidney, stomach and intestine, heart, blood vessel, bone and arthrosis, and tumor tissues using 'in-line' phase contrast imaging and diffraction-enhanced imaging. It is seen that the synchrotron radiation graphs show much higher resolution. This method is especially suitable for studying soft tissue structure and blood vessels. (authors)

  6. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease

    NARCIS (Netherlands)

    Spithoven, E. M.; Meijer, E.; Borns, C.; Boertien, W. E.; Gaillard, C. A. J. M.; Kappert, P.; Greuter, M. J. W.; van der Jagt, E.; Vart, P.; de Jong, P. E.; Gansevoort, R. T.

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBFMRI) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values.

  7. Determination of comprehensive arterial blood inflow in abdominal-pelvic organs: impact of respiration and posture on organ perfusion.

    Science.gov (United States)

    Osada, Takuya; Nagata, Hiroyasu; Murase, Norio; Kime, Ryotaro; Katsumura, Toshihito

    2011-02-01

    Arterial blood flow (BF) to all abdominal-pelvic organs (AP) shows potential for an indicator of comprehensive splanchnic organ circulation (reservoir of blood supply for redistribution) in cardiovascular disease, hepato-gastrointestinal disease or hemodynamic disorders. Our previous assessment of splanchnic hemodynamics, as magnitude of BFAP [measuring by subtracting BF in both femoral arteries (FAs) from the upper abdominal aorta (Ao) above the celiac trunk] using Doppler ultrasound, was reported as the relationship between Ao and FAs, day-to-day variability and response to exercise. For accurate determination of BFAP, it is important to consider the various factors that potentially influence BFAP. However, little information exists regarding the influence of respiration (interplay between inspiration and expiration) and posture on BFAP. Ten healthy males were evaluated in sitting/supine positions following a 12 hr fast. Magnitude of BFAP was determined as measurement of Ao and FAs hemodynamics (blood velocity and vessel diameter) using pulsed Doppler with spectral analysis during spontaneous 4-sec inspiration/4-sec expiration phases. BF/blood velocity in the Ao and FAs showed significant lower in inspiration than expiration. BFAP showed a significant (Ppressure during breathing (thoracic-abdominal movement) is possibly reflecting transient changes in blood velocity in the Ao and FAs. Respiratory effects should be taken into account for evaluation of BFAP.

  8. Generalized Phase Contrast

    CERN Document Server

    Glückstad, Jesper

    2009-01-01

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast (GPC) method including an overview of the range of current and potential applications of GPC in wavefront sensing and phase imaging, structured laser illumination and image projection, optical trapping and manipulation, and optical encryption and decryption. The GPC method goes further than the restrictive assumptions of conventional Zernike phase contrast analysis and achieves an expanded range of validity beyond weak phase perturbations. The generalized analysis yields design criteria for tuning experimental parameters to achieve optimal performance in terms of accuracy, fidelity and light efficiency. Optimization can address practical issues, such as finding an optimal spatial filter for the chosen application, ...

  9. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  10. Free-breathing black-blood CINE fast-spin echo imaging for measuring abdominal aortic wall distensibility: a feasibility study

    Science.gov (United States)

    Lin, Jyh-Miin; Patterson, Andrew J.; Chao, Tzu-Cheng; Zhu, Chengcheng; Chang, Hing-Chiu; Mendes, Jason; Chung, Hsiao-Wen; Gillard, Jonathan H.; Graves, Martin J.

    2017-05-01

    The paper reports a free-breathing black-blood CINE fast-spin echo (FSE) technique for measuring abdominal aortic wall motion. The free-breathing CINE FSE includes the following MR techniques: (1) variable-density sampling with fast iterative reconstruction; (2) inner-volume imaging; and (3) a blood-suppression preparation pulse. The proposed technique was evaluated in eight healthy subjects. The inner-volume imaging significantly reduced the intraluminal artifacts of respiratory motion (p  =  0.015). The quantitative measurements were a diameter of 16.3  ±  2.8 mm and wall distensibility of 2.0  ±  0.4 mm (12.5  ±  3.4%) and 0.7  ±  0.3 mm (4.1  ±  1.0%) for the anterior and posterior walls, respectively. The cyclic cross-sectional distensibility was 35  ±  15% greater in the systolic phase than in the diastolic phase. In conclusion, we developed a feasible CINE FSE method to measure the motion of the abdominal aortic wall, which will enable clinical scientists to study the elasticity of the abdominal aorta.

  11. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  12. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  13. Using the phase-space imager to analyze partially coherent imaging systems: bright-field, phase contrast, differential interference contrast, differential phase contrast, and spiral phase contrast

    Science.gov (United States)

    Mehta, Shalin B.; Sheppard, Colin J. R.

    2010-05-01

    Various methods that use large illumination aperture (i.e. partially coherent illumination) have been developed for making transparent (i.e. phase) specimens visible. These methods were developed to provide qualitative contrast rather than quantitative measurement-coherent illumination has been relied upon for quantitative phase analysis. Partially coherent illumination has some important advantages over coherent illumination and can be used for measurement of the specimen's phase distribution. However, quantitative analysis and image computation in partially coherent systems have not been explored fully due to the lack of a general, physically insightful and computationally efficient model of image formation. We have developed a phase-space model that satisfies these requirements. In this paper, we employ this model (called the phase-space imager) to elucidate five different partially coherent systems mentioned in the title. We compute images of an optical fiber under these systems and verify some of them with experimental images. These results and simulated images of a general phase profile are used to compare the contrast and the resolution of the imaging systems. We show that, for quantitative phase imaging of a thin specimen with matched illumination, differential phase contrast offers linear transfer of specimen information to the image. We also show that the edge enhancement properties of spiral phase contrast are compromised significantly as the coherence of illumination is reduced. The results demonstrate that the phase-space imager model provides a useful framework for analysis, calibration, and design of partially coherent imaging methods.

  14. Phase contrast image synthesis

    DEFF Research Database (Denmark)

    Glückstad, J.

    1996-01-01

    A new method is presented for synthesizing arbitrary intensity patterns based on phase contrast imaging. The concept is grounded on an extension of the Zernike phase contrast method into the domain of full range [0; 2 pi] phase modulation. By controlling the average value of the input phase funct...... function and by choosing appropriate phase retardation at the phase contrast filter, a pure phase to intensity imaging is accomplished. The method presented is also directly applicable in dark field image synthesis....

  15. DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging.

    Science.gov (United States)

    Saranathan, Manojkumar; Rettmann, Dan W; Hargreaves, Brian A; Clarke, Sharon E; Vasanawala, Shreyas S

    2012-06-01

    To develop and evaluate a multiphasic contrast-enhanced MRI method called DIfferential Sub-sampling with Cartesian Ordering (DISCO) for abdominal imaging. A three-dimensional, variable density pseudo-random k-space segmentation scheme was developed and combined with a Dixon-based fat-water separation algorithm to generate high temporal resolution images with robust fat suppression and without compromise in spatial resolution or coverage. With institutional review board approval and informed consent, 11 consecutive patients referred for abdominal MRI at 3 Tesla (T) were imaged with both DISCO and a routine clinical three-dimensional SPGR-Dixon (LAVA FLEX) sequence. All images were graded by two radiologists using quality of fat suppression, severity of artifacts, and overall image quality as scoring criteria. For assessment of arterial phase capture efficiency, the number of temporal phases with angiographic phase and hepatic arterial phase was recorded. There were no significant differences in quality of fat suppression, artifact severity or overall image quality between DISCO and LAVA FLEX images (P > 0.05, Wilcoxon signed rank test). The angiographic and arterial phases were captured in all 11 patients scanned using the DISCO acquisition (mean number of phases were two and three, respectively). DISCO effectively captures the fast dynamics of abdominal pathology such as hyperenhancing hepatic lesions with a high spatio-temporal resolution. Typically, 1.1 × 1.5 × 3 mm spatial resolution over 60 slices was achieved with a temporal resolution of 4-5 s. Copyright © 2012 Wiley Periodicals, Inc.

  16. 10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography

    International Nuclear Information System (INIS)

    Choi, Sun Kyou; Chon, Dong Kwon; Han, Young Min; Kim, Chong Soo; Sohn, Myung Hee; Song, Ho Young; Choi, Ki Chul

    1990-01-01

    CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from duodenal C-loop is better in patients receiving 10% COE than in patients receiving conventional oral contrast agent. 4. In patients receiving 10% COE, differentiation of cystic masses from intestinal loops is sometimes difficult. The results of this study indicate that 10% COE may be useful oral contrast agent for optimal visualization of gastric mucosa and pancreatico-duodenal discrimination on abdominal CT

  17. Peripheral blood eosinophilia associated with gastrointestinal administration of iodinated contrast media.

    Science.gov (United States)

    Plavsic, Branko M; Newman, Alan C; Reuther, Warren L; Terry, James A; Drnovsek, Valerie H

    2003-03-01

    This study was designed to assess whether gastrointestinal administration of iodinated contrast media results in peripheral blood eosinophilia. We studied 110 patients in a retrospective review. Diatrizoate meglumine and diatrizoate sodium for abdominal CT were administered to 98 of these patients; 22 of the 98 had also been given the same contrast medium administered by enema. The remaining 12 patients were given diatrizoate sodium for gastrointestinal fluoroscopy. A control group of 65 patients underwent single-contrast barium upper gastrointestinal or enema examinations. WBC and eosinophil counts were determined approximately 24 hr before the examination and every 24 hr thereafter, through the ninth day. Eosinophilia was detected in 17 (15.5%) of 110 patients after gastrointestinal administration of iodinated contrast media. The prevalence of eosinophilia after administration of iodinated contrast media was statistically significantly different compared with that in the control group, in which none of the 65 patients had eosinophilia (p contrast agents and lasted through the sixth day, with a peak on the fifth day. The prevalence of eosinophilia was independent of route of application, dose, or type of iodinated contrast medium. Eosinophilia in all cases was clinically asymptomatic. Eosinophilia that is caused by gastrointestinal administration of iodinated contrast media is a transient, clinically silent phenomenon. It may lead to unnecessary workup for known conditions associated with eosinophilia.

  18. Ex vivo characterization of pathologic fluids with quantitative phase-contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Vivien, E-mail: vivien.richter@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Hoppe-Seyler-Weg 3, 72076 Tuebingen (Germany); Willner, Marian S., E-mail: marian.willner@ph.tum.de [Department of Physics & Institute of Medical Engineering, Technische Universität München, James-Franck-Strasse 1, 85748 Garching (Germany); Henningsen, John, E-mail: john.henningsen@tum.de [Department of Physics & Institute of Medical Engineering, Technische Universität München, James-Franck-Strasse 1, 85748 Garching (Germany); Birnbacher, Lorenz, E-mail: lorenz.birnbacher@ph.tum.de [Department of Physics & Institute of Medical Engineering, Technische Universität München, James-Franck-Strasse 1, 85748 Garching (Germany); Marschner, Mathias, E-mail: mathias.marschner@ph.tum.de [Department of Physics & Institute of Medical Engineering, Technische Universität München, James-Franck-Strasse 1, 85748 Garching (Germany); Herzen, Julia, E-mail: julia.herzen@ph.tum.de [Department of Physics & Institute of Medical Engineering, Technische Universität München, James-Franck-Strasse 1, 85748 Garching (Germany); Kimm, Melanie A., E-mail: melanie.kimm@tum.de [Department of Diagnostic and Interventional Radiology, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); and others

    2017-01-15

    Purpose: X-ray phase-contrast imaging (PCI) provides additional information beyond absorption characteristics by detecting the phase shift of the X-ray beam passing through material. The grating-based system works with standard polychromatic X-ray sources, promising a possible clinical implementation. PCI has been shown to provide additional information in soft-tissue samples. The aim of this study was to determine if ex vivo quantitative phase-contrast computed tomography (PCCT) may differentiate between pathologic fluid collections. Materials and methods: PCCT was performed with the grating interferometry method. A protein serial dilution, human blood samples and 17 clinical samples of pathologic fluid retentions were imaged and correlated with clinical chemistry measurements. Conventional and phase-contrast tomography images were reconstructed. Phase-contrast Hounsfield Units (HUp) were used for quantitative analysis analogously to conventional HU. The imaging was analyzed using overall means, ROI values as well as whole-volume-histograms and vertical gradients. Contrast to noise ratios were calculated between different probes and between imaging methods. Results: HUp showed a very good linear correlation with protein concentration in vitro. In clinical samples, HUp correlated rather well with cell count and triglyceride content. PCI was better than absorption imaging at differentiating protein concentrations in the protein samples as well as at differentiating blood plasma from cellular components. PCI also allowed for differentiation of watery samples (such as lymphoceles) from pus. Conclusion: Phase-contrast computed tomography is a promising tool for the differentiation of pathologic fluids that appear homogenous with conventional attenuation imaging.

  19. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  20. Is dual-phase abdominal CT necessary for the optimal detection of metastases from renal cell carcinoma?

    International Nuclear Information System (INIS)

    Jain, Y.; Liew, S.; Taylor, M.B.; Bonington, S.C.

    2011-01-01

    Aim: To determine whether dual-phase abdominal computed tomography (CT) detected more metastases than portal-phase CT alone in patients with renal cell carcinoma (RCC). Materials and methods: Audit committee approval was obtained. A retrospective audit was undertaken in 100 patients who underwent both arterial and portal phase CT. The CT images were independently reviewed by two consultant radiologists. The presence of metastases in the liver, pancreas, and contralateral kidney were recorded for each phase of contrast enhancement. Results: Metastases were identified in the liver in 27 patients, pancreas in 12, and contralateral kidney in 23 patients. Nine of the 27 (33%) liver metastases, three of the 12 (25%) pancreatic metastases, and two of the 23 (9%) renal metastases were only detected in the arterial phase, whilst four of the 27 (15%) liver metastases, three of the 12 (25%) pancreatic metastases, and two of the 23 (9%) renal metastases were only detected in the portal phase. Nine patients (9%) had metastases only visualized in the arterial phase, and six (6%) only in the portal phase. Detection of metastases only visible in the arterial phase led to a change of management in two patients (2%). Conclusion: The audit results support our current standard of dual-phase abdominal CT for optimal detection of RCC metastases.

  1. Digital luminescence radiography and conventional radiography in abdominal contrast examinations

    International Nuclear Information System (INIS)

    Krug, B.; Harnischmacher, U.; Krahe, T.; Fischbach, R.; Altenburg, A.; Krings, F.

    1995-01-01

    In 326 patients abdominal contrast radiographs were compared to digital luminescence radiographs (DLR) and conventional screen-film system ones. The digital exposure dose was 50% of the conventional. In DLR, 2 different types of postprocessed images were obtained from each data set. A display with low spatial frequency enhancement filtered to look like a conventional radiograph was compared to a display with high spatial frequency enhancement. Conventional and DLR images were evaluated randomly and separately by 4 radiologists by means of a questionnaire. DLR proved to be diagnostically equivalent to the conventional technique with the exception of a slightly diminished visibility of the mucosal pattern. High spatial frequency enhancement did not provide additional diagnostic information and should be dispensed with in abdominal examinations. (orig.)

  2. Measurement of cerebral blood flow in normal subjects by phase contrast MR imaging

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Inoue, Yusuke; Osada, Hisato

    1994-01-01

    Global cerebral blood flow (CBF) was quantitatively measured with a two-dimensional phase contrast cine magnetic resonance (MR) imaging technique in 24 normal subjects (mean age, 38.6 years; range, 12-70 years). Cine transverse images of the upper cervical region (32 phases/cardiac cycle) were acquired with a 1.5 Tesla MR imaging unit. In five subjects, measurement of CBF was performed before and after intravenous administration of acetazolamide (DIAMOX, 15 mg/kg). Inter- and intra-observer variations in flow volume measurement were small (r=0.970, standard error of the estimate (SEE)=2.9 ml/min, n=8; r=0.963, SEE=4.6 ml/min, n=40, respectively). In measuring flow velocity, they were inferior to those of flow volume measurement. On a visually determined setting of region of interest (ROI), reproducibility of the measurement of flow velocity was not satisfactory in this study. Thus only the results of flow volume measurement are presented. Mean summed vertebral flow volume (171 ml/min, SD=40.6) was significantly less than mean summed internal carotid flow volume (523 ml/min, SD=111). Total blood flow volume showed a significant decline with age (r=-0.45, p<0.05). The mean proportions of carotid and vertebral flow volume to total flow volume were 75.3% and 24.7%, respectively, and showed no significant change with age. The left-to-right ratio of vertebral flow volume (1.39) was significantly higher than that of internal carotid flow volume (0.99, r=0.05). After DIAMOX i.v., the mean rate of increase in total flow volume was 157%. Mean rates of increase in carotid and vertebral flow volume were 154% and 166%, respectively, which were not significantly different. In conclusion, this method is useful for estimating carotid and vertebral flow volume. (author)

  3. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  4. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  5. Abdominal 64-MDCT for suspected appendicitis: the use of oral and IV contrast material versus IV contrast material only.

    Science.gov (United States)

    Anderson, Stephan W; Soto, Jorge A; Lucey, Brian C; Ozonoff, Al; Jordan, Jacqueline D; Ratevosian, Jirair; Ulrich, Andrew S; Rathlev, Niels K; Mitchell, Patricia M; Rebholz, Casey; Feldman, James A; Rhea, James T

    2009-11-01

    The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiologists. Individual reader performance and a combined interpretation performance of the two readers assigned to each case were calculated. In cases of disagreement, the third reader was asked to deliver a tiebreaker interpretation to be used to calculate the combined reader performance. Final outcome was based on operative, clinical, and follow-up data. We compared radiologic diagnoses with clinical outcomes to calculate the diagnostic accuracy of CT in both groups. Of the 303 patients enrolled, 151 patients (50%) were randomized to group 1 and the remaining 152 (50%) were randomized to group 2. The combined reader performance for the diagnosis of appendicitis in group 1 was a sensitivity of 100% (95% CI, 76.8-100%) and specificity of 97.1% (95% CI, 92.7-99.2%). The performance in group 2 was a sensitivity of 100% (73.5-100%) and specificity of 97.1% (92.9-99.2%). Patients presenting with nontraumatic abdominal pain imaged using 64-MDCT with isotropic reformations had similar characteristics for the

  6. Emergency CT in blunt abdominal trauma of multiple injury patients

    International Nuclear Information System (INIS)

    Kinnunen, J.; Kivioja, A.; Poussa, K.; Laasonen, E.M.

    1994-01-01

    Multiple injury patients with blunt abdominal trauma (n = 110) were examined by abdominal CT. An i.v., but not peroral, contrast medium was used, thereby eliminating the delay caused by administering peroral contrast medium and any subsequent delay in making the diagnoses and beginning operative treatment. Eighteen patients underwent emergency laparotomy after the initial CT examination. The preoperative CT findings were compared to the laparotomy findings. CT revealed all but one of the severe parenchymal organ lesions requiring surgery. The one liver laceration that went undetected had caused hemoperitoneum, which was diagnosed by CT. The bowel and mesenteric lesions presented as intra-abdominal blood, and the hemoperitoneum was discovered in every patient with these lesions. Fourteen patients also initially had positive abdominal CT findings; 10 of them underwent an additional abdominal CT within 3 days, but the repeat studies did not reveal any lesions in need of surgery. Omission of the oral contrast medium did not jeopardize making the essential diagnoses, but it did save time. (orig.)

  7. Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging

    International Nuclear Information System (INIS)

    Serai, Suraj; Towbin, Alexander J.; Podberesky, Daniel J.

    2012-01-01

    Abdominal contrast-enhanced MR angiography (CE-MRA) is routinely performed in children. CE-MRA is challenging in children because of patient motion, difficulty in obtaining intravenous access, and the inability of young patients to perform a breath-hold during imaging. The combination of pediatric-specific difficulties in imaging and the safety concerns regarding the risk of gadolinium-based contrast agents in patients with impaired renal function has renewed interest in the use of non-contrast (NC) MRA techniques. At our institution, we have optimized 3-D NC-MRA techniques for abdominal imaging. The purpose of this work is to demonstrate the utility of an inflow-enhanced, inversion recovery balanced steady-state free precession-based (b-SSFP) NC-MRA technique. (orig.)

  8. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  9. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  10. Genetic parameters for the prediction of abdominal fat traits using blood biochemical indicators in broilers.

    Science.gov (United States)

    Zhang, H L; Xu, Z Q; Yang, L L; Wang, Y X; Li, Y M; Dong, J Q; Zhang, X Y; Jiang, X Y; Jiang, X F; Li, H; Zhang, D X; Zhang, H

    2018-02-01

    1. Excessive deposition of body fat, especially abdominal fat, is detrimental in chickens and the prevention of excessive fat accumulation is an important problem. The aim of this study was to identify blood biochemical indicators that could be used as criteria to select lean Yellow-feathered chicken lines. 2. Levels of blood biochemical indicators in the fed and fasted states and the abdominal fat traits were measured in 332 Guangxi Yellow chickens. In the fed state, the genetic correlations (r g ) of triglycerides and very low density lipoprotein levels were positive for the abdominal fat traits (0.47 ≤ r g  ≤ 0.67), whereas total cholesterol, high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C) showed higher negative correlations with abdominal fat traits (-0.59 ≤ r g  ≤ -0.33). Heritabilities of these blood biochemical parameters were high, varying from 0.26 to 0.60. 3. In the fasted state, HDL-C:LDL-C level was positively correlated with abdominal fat traits (0.35 ≤ r g  ≤ 0.38), but triglycerides, total cholesterol, HDL-C, LDL-C, total protein, albumin, aspartate transaminase, uric acid and creatinine levels were negatively correlated with abdominal fat traits (-0.79 ≤ r g  ≤ -0.35). The heritabilities of these 10 blood biochemical parameters were high (0.22 ≤ h 2  ≤ 0.59). 4. In the fed state, optimal multiple regression models were constructed to predict abdominal fat traits by using triglycerides and LDL-C. In the fasted state, triglycerides, total cholesterol, HDL-C, LDL-C, total protein, albumin and uric acid could be used to predict abdominal fat content. 5. It was concluded that these models in both nutritional states could be used to predict abdominal fat content in Guangxi Yellow broiler chickens.

  11. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Spithoven, E.M.; Meijer, E.; Boertien, W.E.; Gaillard, C.A.J.M.; Jong, P.E. de; Gansevoort, R.T. [University of Groningen, Department of Nephrology, Community and Occupational Medicine, University Medical Center Groningen, PO Box 30.001, RB Groningen (Netherlands); Borns, C.; Kappert, P.; Greuter, M.J.W.; Jagt, E. van der [University of Groningen, Department of Radiology, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands); Vart, P. [University of Groningen, Department of Health Sciences, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands)

    2016-03-15

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBF{sub MRI}) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. First, we validated RBF{sub MRI} measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBF{sub MRI}. After validation, we measured RBF{sub MRI} in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBF{sub MRI} and RBF measured by continuous hippuran infusion. The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBF{sub MRI} measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBF{sub MRI} compared to RBF{sub Hip,} whereas in subjects with lower eGFRs, this was significantly less for RBF{sub MRI}. Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. (orig.)

  12. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    Science.gov (United States)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  13. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study.

    Science.gov (United States)

    Kammerer, S; Höink, A J; Wessling, J; Heinzow, H; Koch, R; Schuelke, C; Heindel, W; Buerke, B

    2015-03-01

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified "clearly delimitable" more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast.

  14. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Karmonik, C.; Benndorf, G. [The Methodist Hospital Research Inst., Houston (United States). Radiology; Klucznik, R. [The Methodist Hospital, Houston (United States). Radiology

    2008-03-15

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. {+-}60 to {+-}100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  15. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    International Nuclear Information System (INIS)

    Karmonik, C.; Benndorf, G.; Klucznik, R.

    2008-01-01

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. ±60 to ±100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  16. Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: Initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium

    International Nuclear Information System (INIS)

    Christie, A.; Chandramohan, S.; Roditi, G.

    2013-01-01

    Aim: To compare extended-phase imaging using an extracellular space contrast agent, gadobenate dimeglumine, to imaging with a blood-pool contrast agent, gadofosveset, for magnetic resonance angiography. Materials and methods: A lower-limb magnetic resonance angiography (MRA) protocol (dynamic crural, three-station bolus chase, and infra-inguinal high resolution) designed for blood-pool agent imaging was adapted for use with the extracellular agent, gadobenate dimeglumine, primarily by using a triphasic injection protocol. Ten patients scanned with gadofosveset were compared to 10 patients scanned with gadobenate. The dynamic, bolus chase, and high-resolution images were scored for quality on a Likert scale (from 1–5). Signal- and contrast-to-noise ratios were analysed, and Mann–Whitney U statistical analysis performed. Results: There was no significant difference for the dynamic imaging or the aorto-iliac station of the bolus chase. Infra-inguinal bolus chase images were higher quality (p < 0.05 Mann–Whitney U test) with gadobenate. Signal analysis confirmed lower signal and contrast for venous imaging on the high spatial resolution acquisitions with gadobenate; however, this allowed improved arterial conspicuity. Conclusion: Extended-phase imaging using an extracellular space contrast agent is feasible and provides image quality to equal imaging with a blood-pool contrast agent.

  17. Benchtop phase-contrast X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: o.gundogdu@surrey.ac.uk; Nirgianaki, E.; Che Ismail, E.; Jenneson, P.M.; Bradley, D.A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2007-12-15

    Clinical radiography has traditionally been based on contrast obtained from absorption when X-rays pass through the body. The contrast obtained from traditional radiography can be rather poor, particularly when it comes to soft tissue. A wide range of media of interest in materials science, biology and medicine exhibit very weak absorption contrast, but they nevertheless produce significant phase shifts with X-rays. The use of phase information for imaging purposes is therefore an attractive prospect. Some of the X-ray phase-contrast imaging methods require highly monochromatic plane wave radiation and sophisticated X-ray optics. However, the propagation-based phase-contrast imaging method adapted in this paper is a relatively simple method to implement, essentially requiring only a microfocal X-ray tube and electronic detection. In this paper, we present imaging results obtained from two different benchtop X-ray sources employing the free space propagation method. X-ray phase-contrast imaging provides higher contrast in many samples, including biological tissues that have negligible absorption contrast.

  18. NMR multiple-echo phase-contrast blood flow imaging

    International Nuclear Information System (INIS)

    O'Donnell, M.

    1986-01-01

    A method is described for magnetic resonance imaging of fluid flow in a sample, comprising the steps of: (a) immersing the sample in a static magnetic field disposed in a first direction; (b) applying a first sequence of magnetic field gradients and radio-frequency signals to the sample to both define a slab, of the sample to be imaged, in a plane substantially orthogonal to a selected direction for which flow velocity is to be measured, and to obtain a plurality N of spin-echo response signals form that slab; (c) processing the plurality of first sequence spin-echo signals to obtain a complex value A/sub 1/(X,Y,Z) relating both the spin density rho'(X,Y,Z),... and the phase rotation phi(X,Y,Z), induced by the first sequence, for each of a selected number of sequential locations (X,Y,Z) in the sample slab; (d) applying a second sequence of magnetic field gradient and radio-frequency signals to both define the same sample slab as in step (b) and to obtain another plurality N of spin-echo response signals from that slab; (e) including a waveform in at least one of the magnetic field gradient and radio-frequency signals applied in step (d) for imparting to each of the spin-echo signal components from each slab location having a flowing material therein a phase rotation dependent upon the magnitude of the flow velocity therein in the selected direction; (f) processing the plurality of second sequence spin-echo signals to obtain a complex value A/sub 2/(X,Y,Z) relating the spin density rho'(X,Y,Z) and the imparted phase rotation of the sample material along the selected flow measurement direction for each of the sequential locations (X,Y,Z) in the sample slab; and (g) processing the complex values A/sub 1/(X,Y,Z) and A/sub 2/(X,Y,Z) for each sample location to obtain a differential phase-contrast value related to the velocity of the flowing material therein in the selected measurement direction

  19. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kammerer, S.; Hoeink, A.J.; Wessling, J.; Schuelke, C.; Heindel, W.; Buerke, B. [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Heinzow, H. [University Hospital Muenster, Department of Gastroenterology and Metabolic Diseases, Muenster (Germany); Koch, R. [University Muenster, Institute of Biostatistics and Clinical Research, Muenster (Germany)

    2014-10-15

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified ''clearly delimitable'' more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast. circle Neutral oral contrast ensures an equivalent delineation of the bowel. (orig.)

  20. Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stock, K.W.; Wetzel, S.G.; Radue, E.W. [Dept. of Radiology, Division of Neuroradiology, University Hospital of Basel (Switzerland); Lyrer, P.A. [Dept. of Neurology, University Hospital of Basel (Switzerland)

    2000-11-01

    The aim of this study was to assess blood flow in the middle cerebral artery (MCA) according to age, gender, and side. Eighty-eight subjects without carotid obstruction were measured for mean velocity, vessel area, and volume flow rates of both MCA with phase-contrast MR. A high-resolution sequence with a matrix of 300 x 512 and a double oblique localizing strategy was used for measurement. A mean velocity of 33 {+-} 6.8 cm/s, a mean vessel area of 6.2 {+-} 1.2 mm{sup 2} and a mean flow rate of 121 {+-} 28 ml/min were measured in the MCA. Lower volume flow rates were seen in subjects aged over 50 years (p < 0.01). When comparing women with men, a lower vessel area (p < 0.05) of the MCA was counterbalanced by a higher velocity, resulting in no significant difference of the volume flow rate. No difference occurred between the right and the left side. Flow reduction occurs in the elderly. A lower vessel area of the MCA in women is compensated by a higher velocity. (orig.)

  1. Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging

    International Nuclear Information System (INIS)

    Stock, K.W.; Wetzel, S.G.; Radue, E.W.; Lyrer, P.A.

    2000-01-01

    The aim of this study was to assess blood flow in the middle cerebral artery (MCA) according to age, gender, and side. Eighty-eight subjects without carotid obstruction were measured for mean velocity, vessel area, and volume flow rates of both MCA with phase-contrast MR. A high-resolution sequence with a matrix of 300 x 512 and a double oblique localizing strategy was used for measurement. A mean velocity of 33 ± 6.8 cm/s, a mean vessel area of 6.2 ± 1.2 mm 2 and a mean flow rate of 121 ± 28 ml/min were measured in the MCA. Lower volume flow rates were seen in subjects aged over 50 years (p < 0.01). When comparing women with men, a lower vessel area (p < 0.05) of the MCA was counterbalanced by a higher velocity, resulting in no significant difference of the volume flow rate. No difference occurred between the right and the left side. Flow reduction occurs in the elderly. A lower vessel area of the MCA in women is compensated by a higher velocity. (orig.)

  2. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Brain magnetic resonance imaging with contrast dependent on blood oxygenation

    International Nuclear Information System (INIS)

    Ogawa, S.; Lee, T.M.; Kay, A.R.; Tank, D.W.

    1990-01-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high yields, the authors demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complement other techniques that are attempting to provide position emission tomography-like measurements related to regional neural activity

  4. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  5. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    Science.gov (United States)

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  6. The effect of transluminal stent-graft placement on blood flow of abdominal branch vessels in type B aortic dissection

    International Nuclear Information System (INIS)

    Huang Lianjun; Yang Jian; Yu Feicheng; Sun Lizhong; Zhu Junming; Zhang Yan; Jiang Shiliang

    2005-01-01

    Objective: To evaluate the effect of TSGP on blood flow of abdominal branch vessels of Type B dissection. Methods: Thirty-five patients with type B aortic dissection underwent TSGP. The blood flow of abdominal branch vessels was analyzed via EBCT, MRI, and DSA before and after procedure. Results: A total of 140 important vessels from abdominal aorta in 35 patients, including celiac artery, SMA, right and left renal arteries were analyzed via EBCT, MRI, and DSA. 58 branches were affected by dissection, of which 14 (10% ) were dynamic impairment; and 44 (31.4%) were static impairment. After TSGP, the blood flow of impaired branches all showed improvement at different degrees, no post-operative ischemic complications occurred. Conclusion: TSGP could improve the blood flow immediately not only the dynamic but also the static ischemia of abdominal aorta branch vessels caused by type B aortic dissection. Further study is still need to observe the mid-term and long-term effect of TSGP. (authors)

  7. A novel anisotropic fast marching method and its application to blood flow computation in phase-contrast MRI.

    Science.gov (United States)

    Schwenke, M; Hennemuth, A; Fischer, B; Friman, O

    2012-01-01

    Phase-contrast MRI (PC MRI) can be used to assess blood flow dynamics noninvasively inside the human body. The acquired images can be reconstructed into flow vector fields. Traditionally, streamlines can be computed based on the vector fields to visualize flow patterns and particle trajectories. The traditional methods may give a false impression of precision, as they do not consider the measurement uncertainty in the PC MRI images. In our prior work, we incorporated the uncertainty of the measurement into the computation of particle trajectories. As a major part of the contribution, a novel numerical scheme for solving the anisotropic Fast Marching problem is presented. A computing time comparison to state-of-the-art methods is conducted on artificial tensor fields. A visual comparison of healthy to pathological blood flow patterns is given. The comparison shows that the novel anisotropic Fast Marching solver outperforms previous schemes in terms of computing time. The visual comparison of flow patterns directly visualizes large deviations of pathological flow from healthy flow. The novel anisotropic Fast Marching solver efficiently resolves even strongly anisotropic path costs. The visualization method enables the user to assess the uncertainty of particle trajectories derived from PC MRI images.

  8. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  9. Diagnostic performance of contrast-enhanced MR for acute appendicitis and alternative causes of abdominal pain in children

    Energy Technology Data Exchange (ETDEWEB)

    Koning, Jeffrey L. [University of California San Diego, Department of Radiology, San Diego, CA (United States); Naheedy, John H.; Kruk, Peter G. [University of California San Diego, Department of Radiology, San Diego, CA (United States); Rady Children' s Hospital, Department of Radiology, San Diego, CA (United States)

    2014-08-15

    Unenhanced MRI has emerged as a useful tool for diagnosing pediatric acute appendicitis. The use of contrast-enhanced MRI for diagnosing pediatric appendicitis has not been documented. The purpose of this study is to examine the diagnostic performance of contrast-enhanced MRI for acute appendicitis and alternative entities in the pediatric population presenting with acute abdominal pain. A retrospective review was conducted of 364 consecutive pediatric patients undergoing contrast-enhanced MRI for the evaluation of possible appendicitis at a single institution between November 2012 and September 2013. There were 132 cases of pathologically confirmed appendicitis out of 364 pediatric patients (36.3%) included in the study. Overall sensitivity and specificity were 96.2% (95% CI [91.4-98.4%]) and 95.7% (95% CI [92.3-97.6%]), respectively. Positive predictive value and negative predictive value were 92.7% (95% CI [86.6-96.3%]) and 97.8% (95% CI [94.7-99.1%]), respectively. The appendix was visualized in 243 cases (66.8%). Imaging confirmed alternative diagnoses in 75 patients, including most commonly colitis, enteritis or terminal ileitis (n = 25, 6.9%), adnexal cysts (n = 25, 6.9%) and mesenteric adenitis (n = 7, 1.9%). Contrast-enhanced MRI is capable of accurately diagnosing acute appendicitis while detecting many alternative entities of abdominal pain, and it allows good visualization of the appendix. Further evaluation is needed to determine whether contrast-enhanced MRI provides an advantage over non-enhanced MRI for imaging evaluation of acute abdominal pain in the pediatric population. (orig.)

  10. Diagnostic performance of contrast-enhanced MR for acute appendicitis and alternative causes of abdominal pain in children

    International Nuclear Information System (INIS)

    Koning, Jeffrey L.; Naheedy, John H.; Kruk, Peter G.

    2014-01-01

    Unenhanced MRI has emerged as a useful tool for diagnosing pediatric acute appendicitis. The use of contrast-enhanced MRI for diagnosing pediatric appendicitis has not been documented. The purpose of this study is to examine the diagnostic performance of contrast-enhanced MRI for acute appendicitis and alternative entities in the pediatric population presenting with acute abdominal pain. A retrospective review was conducted of 364 consecutive pediatric patients undergoing contrast-enhanced MRI for the evaluation of possible appendicitis at a single institution between November 2012 and September 2013. There were 132 cases of pathologically confirmed appendicitis out of 364 pediatric patients (36.3%) included in the study. Overall sensitivity and specificity were 96.2% (95% CI [91.4-98.4%]) and 95.7% (95% CI [92.3-97.6%]), respectively. Positive predictive value and negative predictive value were 92.7% (95% CI [86.6-96.3%]) and 97.8% (95% CI [94.7-99.1%]), respectively. The appendix was visualized in 243 cases (66.8%). Imaging confirmed alternative diagnoses in 75 patients, including most commonly colitis, enteritis or terminal ileitis (n = 25, 6.9%), adnexal cysts (n = 25, 6.9%) and mesenteric adenitis (n = 7, 1.9%). Contrast-enhanced MRI is capable of accurately diagnosing acute appendicitis while detecting many alternative entities of abdominal pain, and it allows good visualization of the appendix. Further evaluation is needed to determine whether contrast-enhanced MRI provides an advantage over non-enhanced MRI for imaging evaluation of acute abdominal pain in the pediatric population. (orig.)

  11. Accuracy of pre-contrast imaging in abdominal magnetic resonance imaging of pediatric oncology patients

    International Nuclear Information System (INIS)

    Mohd Zaki, Faizah; Moineddin, Rahim; Grant, Ronald; Chavhan, Govind B.

    2016-01-01

    Safety concerns are increasingly raised regarding the use of gadolinium-based contrast media for MR imaging. To determine the accuracy of pre-contrast abdominal MR imaging for lesion detection and characterization in pediatric oncology patients. We included 120 children (37 boys and 83 girls; mean age 8.94 years) referred by oncology services. Twenty-five had MRI for the first time and 95 were follow-up scans. Two authors independently reviewed pre-contrast MR images to note the following information about the lesions: location, number, solid vs. cystic and likely nature. Pre- and post-contrast imaging reviewed together served as the reference standard. The overall sensitivity was 88% for the first reader and 90% for the second; specificity was 94% and 91%; positive predictive value was 96% and 94%; negative predictive value was 82% and 84%; accuracy of pre-contrast imaging for lesion detection as compared to the reference standard was 90% for both readers. The difference between mean number of lesions detected on pre-contrast imaging and reference standard was not significant for either reader (reader 1, P = 0.072; reader 2, P = 0.071). There was substantial agreement (kappa values of 0.76 and 0.72 for readers 1 and 2) between pre-contrast imaging and reference standard for determining solid vs. cystic lesion and likely nature of the lesion. The addition of post-contrast imaging increased confidence of both readers significantly (P < 0.0001), but the interobserver agreement for the change in confidence was poor (kappa 0.12). Pre-contrast abdominal MR imaging has high accuracy in lesion detection in pediatric oncology patients and shows substantial agreement with the reference standard for characterization of lesions. Gadolinium-based contrast media administration cannot be completely eliminated but can be avoided in many cases, with the decision made on a case-by-case basis, taking into consideration location and type of tumor. (orig.)

  12. Accuracy of pre-contrast imaging in abdominal magnetic resonance imaging of pediatric oncology patients

    Energy Technology Data Exchange (ETDEWEB)

    Mohd Zaki, Faizah [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children and Medical Imaging, Toronto, ON (Canada); Universiti Kebangsaan Malaysia Medical Center, Department of Radiology, Kuala Lumpur (Malaysia); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto, ON (Canada); Grant, Ronald [University of Toronto, Department of Hematology and Oncology, The Hospital for Sick Children and Medical Imaging, Toronto, ON (Canada); Chavhan, Govind B. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children and Medical Imaging, Toronto, ON (Canada)

    2016-11-15

    Safety concerns are increasingly raised regarding the use of gadolinium-based contrast media for MR imaging. To determine the accuracy of pre-contrast abdominal MR imaging for lesion detection and characterization in pediatric oncology patients. We included 120 children (37 boys and 83 girls; mean age 8.94 years) referred by oncology services. Twenty-five had MRI for the first time and 95 were follow-up scans. Two authors independently reviewed pre-contrast MR images to note the following information about the lesions: location, number, solid vs. cystic and likely nature. Pre- and post-contrast imaging reviewed together served as the reference standard. The overall sensitivity was 88% for the first reader and 90% for the second; specificity was 94% and 91%; positive predictive value was 96% and 94%; negative predictive value was 82% and 84%; accuracy of pre-contrast imaging for lesion detection as compared to the reference standard was 90% for both readers. The difference between mean number of lesions detected on pre-contrast imaging and reference standard was not significant for either reader (reader 1, P = 0.072; reader 2, P = 0.071). There was substantial agreement (kappa values of 0.76 and 0.72 for readers 1 and 2) between pre-contrast imaging and reference standard for determining solid vs. cystic lesion and likely nature of the lesion. The addition of post-contrast imaging increased confidence of both readers significantly (P < 0.0001), but the interobserver agreement for the change in confidence was poor (kappa 0.12). Pre-contrast abdominal MR imaging has high accuracy in lesion detection in pediatric oncology patients and shows substantial agreement with the reference standard for characterization of lesions. Gadolinium-based contrast media administration cannot be completely eliminated but can be avoided in many cases, with the decision made on a case-by-case basis, taking into consideration location and type of tumor. (orig.)

  13. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography.

    Science.gov (United States)

    Zhang, Tao; Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y; Alley, Marcus T; Lustig, Michael; Pauly, John M; Vasanawala, Shreyas S

    2015-10-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.

  14. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tao; Cheng, Joseph Y. [Stanford University, Department of Radiology, Stanford, CA (United States); Stanford University, Department of Electrical Engineering, Stanford, CA (United States); Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S. [Stanford University, Department of Radiology, Stanford, CA (United States); Hsiao, Albert [University of California, San Diego, Department of Radiology, San Diego, CA (United States); Lustig, Michael [Stanford University, Department of Electrical Engineering, Stanford, CA (United States); University of California, Berkeley, Department of Electrical Engineering and Computer Sciences, Berkeley, CA (United States); Pauly, John M. [Stanford University, Department of Electrical Engineering, Stanford, CA (United States)

    2015-10-15

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  15. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    International Nuclear Information System (INIS)

    Zhang, Tao; Cheng, Joseph Y.; Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S.; Hsiao, Albert; Lustig, Michael; Pauly, John M.

    2015-01-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  16. Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions.

    Science.gov (United States)

    Molins, Inés Gómez; Font, Juan Manuel Fernández; Alvaro, Juan Carrero; Navarro, Jose Luís Lledó; Gil, Marta Fernández; Rodríguez, Conrado M Fernández

    2010-12-28

    The extensive use of imaging techniques in differential diagnosis of abdominal conditions and screening of hepatocellular carcinoma in patients with chronic hepatic diseases, has led to an important increase in identification of focal liver lesions. The development of contrast-enhanced ultrasound (CEUS) opens a new window in the diagnosis and follow-up of these lesions. This technique offers obvious advantages over the computed tomography and magnetic resonance, without a decrease in its sensitivity and specificity. The new second generation contrast agents, due to their intravascular distribution, allow a continuous evaluation of the enhancement pattern, which is crucial in characterization of liver lesions. The dual blood supply in the liver shows three different phases, namely arterial, portal and late phases. The enhancement during portal and late phases can give important information about the lesion's behavior. Each liver lesion has a different enhancement pattern that makes possible an accurate approach to their diagnosis. The role of emerging techniques as a contrast-enhanced three-dimensional US is also discussed. In this article, the advantages, indications and technique employed during CEUS and the different enhancement patterns of most benign and malignant focal liver lesions are discussed.

  17. Abdominal emergencies

    International Nuclear Information System (INIS)

    Raissaki, M.

    2012-01-01

    Full text: There are numerous conditions that affect mainly or exclusively the pediatric population. These constitute true emergencies, related to patient's health. Delay in diagnosis and treatment of abdominal non-traumatic emergencies may result in rapid deterioration, peritonitis, sepsis, even death or in severe complications with subsequent morbidity. Abdominal emergencies in children mostly present with pain, tenderness, occasionally coupled by vomiting, fever, abdominal distension, and failure to pass meconium or stools. Diarrhea, blood per rectum, abnormal laboratory tests and lethargy may also be manifestations of acute abdominal conditions. Abdominal emergencies have a different aetiology, depending on age and whether the pain is acute or chronic. Symptoms have to be matched with age and gender. Newborns up to 1 months of age may have congenital diseases: atresia, low obstruction including Hirschsprung's disease, meconium ileus. Meconium plug is one of the commonest cause of low obstruction in newborns that may also develop necrotizing enterocolitis, incarcerated inguinal hernia and mid-gut volvulus. Past the immediate postnatal period, any duodenal obstruction should be considered midgut volvulus until proven otherwise and patients should undergo ultrasonography and/or properly performed upper GI contrast study that records the exact position of the deduno-jejunal junction. Infants 6 months-2 years carry the risk of intussusception, mid-gut volvulus, perforation, acute pyelonephritis. Preschool and school-aged children 2-12 years carry the risk of appendicitis, genito-urinary abnormalities including torsion, urachal abnormalities, haemolytic uremic syndrome and Henoch-Schonlein purpura. Children above 12 years suffer from the same conditions as in adults. Most conditions may affect any age despite age predilection. Abdominal solid organ ultrasonography (US) coupled with gastrointestinal ultrasonography is the principle imaging modality in radiosensitive

  18. Evaluation of the levels of metalloproteinsase-2 in patients with abdominal aneurysm and abdominal hernias.

    Science.gov (United States)

    Antoszewska, Magdalena

    2013-05-01

    Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant

  19. Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis.

    Science.gov (United States)

    van Amerom, Joshua F P; Kellenberger, Christian J; Yoo, Shi-Joon; Macgowan, Christopher K

    2009-01-01

    An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.

  20. Acute transfusion-related abdominal injury in trauma patients: a case report.

    Science.gov (United States)

    Michel, P; Wähnert, D; Freistühler, M; Laukoetter, M G; Rehberg, S; Raschke, M J; Garcia, P

    2016-10-19

    Secondary abdominal compartment syndrome is well known as a life-threatening complication in critically ill patients in an intensive care unit. Massive crystalloid fluid resuscitation has been identified as the most important risk factor. The time interval from hospital admittance to the development of manifest abdominal compartment syndrome is usually greater than 24 hours. In the absence of any direct abdominal trauma, we observed a rapidly evolving secondary abdominal compartment syndrome shortly after hospital admittance associated with massive transfusion of blood products and only moderate crystalloid resuscitation. We report the case of an acute secondary abdominal compartment syndrome developing within 3 to 4 hours in a 74-year-old polytraumatized white woman. Although multiple fractures of her extremities and a B-type pelvic ring fracture were diagnosed by a full body computed tomography scan, no intra-abdominal injury could be detected. Hemorrhagic shock with a drop in her hemoglobin level to 5.7 g/dl was treated by massive transfusion of blood products and high doses of catecholamines. Shortly afterwards, her pulmonary gas exchange progressively deteriorated and mechanical ventilation became almost impossible with peak airway pressures of up to 60 cmH 2 O. Her abdomen appeared rigid and tense accompanied by a progressive hemodynamic decompensation necessitating mechanic cardiopulmonary resuscitation. Although preoperative computed tomography scans showed no signs of intra-abdominal fluid, a decompressive laparotomy under cardiopulmonary resuscitation conditions was performed and 2 liters of ascites-like fluid disgorged. Her hemodynamics and pulmonary ventilation improved immediately. This case report describes for the first time acute secondary abdominal compartment syndrome in a trauma patient, evolving in a very short time period. We hypothesize that the massive transfusion of blood products along with high doses of catecholamines triggered the acute

  1. Use of three-dimensional time-resolved phase-contrast magnetic resonance imaging with vastly undersampled isotropic projection reconstruction to assess renal blood flow in a renal cell carcinoma patient treated with sunitinib: a case report.

    Science.gov (United States)

    Takayama, Tatsuya; Takehara, Yasuo; Sugiyama, Masataka; Sugiyama, Takayuki; Ishii, Yasuo; Johnson, Kevin E; Wieben, Oliver; Wakayama, Tetsuya; Sakahara, Harumi; Ozono, Seiichiro

    2014-08-14

    New imaging modalities to assess the efficacy of drugs that have molecular targets remain under development. Here, we describe for the first time the use of time-resolved three-dimensional phase-contrast magnetic resonance imaging to monitor changes in blood supply to a tumor during sunitinib treatment in a patient with localized renal cell carcinoma. A 43-year-old Japanese woman with a tumor-bearing but functional single kidney presented at our hospital in July 2012. Computed tomography and magnetic resonance imaging revealed a cT1aN0M0 renal cell carcinoma embedded in the upper central region of the left kidney. She was prescribed sunitinib as neoadjuvant therapy for 8 months, and then underwent partial nephrectomy. Tumor monitoring during this time was done using time-resolved three-dimensional phase-contrast magnetic resonance imaging, a recent technique which specifically measures blood flow in the various vessels of the kidney. This imaging allowed visualization of the redistribution of renal blood flow during treatment, and showed that flow to the tumor was decreased and flows to other areas increased. Of note, this change occurred in the absence of any change in tumor size. The ability of time-resolved three-dimensional phase-contrast magnetic resonance imaging to provide quantitative information on blood supply to tumors may be useful in monitoring the efficacy of sunitinib treatment.

  2. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  3. Effects of iodinated contrast media on common carotid and brachial artery blood flow and wall shear stress

    International Nuclear Information System (INIS)

    Irace, C.; Tamburini, S.; Bertucci, B.; Franceschi, M.S. de; Gnasso, A.

    2006-01-01

    The aim of our study was to evaluate the effect of the intravenous contrast media iomeprol on wall shear stress, blood flow and vascular parameters in the common carotid and brachial artery. Thirty outpatients undergoing thoracic or abdominal spiral CT scans were studied. The internal diameter and flow velocity of the common carotid and brachial artery were evaluated by ultrasound, and blood viscosity was measured before and after low osmolality iomeprol (Iomeron 350) injection. The wall shear stress, blood flow and pulsatility index were calculated. To test the differences between groups, the Wilcoxon rank test and Mann Whitney U test were applied. Blood viscosity decreased slightly, but significantly after contrast media (4.6±0.7 vs. 4.5±0.7 mPa.s, P=0.02). Contrarily, blood flow and wall shear stress did not change in the common carotid artery, but significantly decreased in the brachial artery (0.9±0.4 vs. 0.6±0.3 ml/s, P<0.0001, and 41.5±13.9 vs. 35.3±11.0 dynes/cm2, P<0.002, respectively), whereas the pulsatility index significantly increased in the brachial artery (5.0±3.3 vs. 7.5±5.3, P<0.001). Iomeprol injection causes blood flow and wall shear stress reduction of the brachial artery; the rise in the pulsatility index suggests an increase in peripheral vascular resistance. Further investigation is needed to evaluate whether these modifications can be clinically relevant. (orig.)

  4. Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Lai Wyman W

    2010-03-01

    Full Text Available Abstract Background One potential source of error in phase contrast (PC congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has been shown to result in more accurate measurements of blood flow in adults with structurally normal hearts. We report the effect of phantom correction on PC flow measurements at a clinical congenital CMR program. Results Flow was measured in the ascending aorta, main pulmonary artery, and right and left pulmonary arteries as clinically indicated, and additional values such as Qp/Qs were derived from these measurements. Phantom correction in our study population of 149 patients resulted in clinically significant changes in 13% to 48% of these phase-contrast measurements in patients with known or suspected heart disease. Overall, 640 measurements or calculated values were analyzed, and clinically significant changes were found in 31%. Larger vessels were associated with greater phase offset errors, with 22% of the changes in PC flow measurements attributed to the size of the vessel measured. In patients with structurally normal hearts, the pulmonary-to-systemic flow ratio after phantom correction was closer to 1.0 than before phantom correction. There was no significant difference in the effect of phantom correction for patients with tetralogy of Fallot as compared to the group as a whole. Conclusions Phantom correction often resulted in clinically significant changes in PC blood flow measurements in patients with known or suspected congenital heart disease. In laboratories performing clinical CMR with suspected phase offset errors of significance, the routine use of phantom correction for PC flow measurements should be considered.

  5. Phase contrast X-ray imaging at the bone-cartilage interface

    International Nuclear Information System (INIS)

    Che Ismail, E.; Gundogdu, O.; Bradley, D.A.

    2008-01-01

    Full text: Phase contrast X-ray imaging is a simple technique to investigate various biological samples. At Surrey, the bone-cartilage interface is one of the biological samples which actively been studied. Bone-cartilage interface study gives a particular interest in this research as the degeneration of cartilage is the hallmark of the degenerative joint disease such as osteoarthritis. We have been applying the phase contrast imaging technique in studying the bone-cartilage interface, obtaining information on anatomical features such as the cartilage, blood vessel, tide mark and cement line. Our samples range from dry bone-cartilage to wet bone-cartilage tissue. This work will briefly review the basic supporting physics of the study. It also shows some of the images and other results that we have obtained to-date. Fig. 1 shows examples obtained using the X-ray tube system at the University of Surrey

  6. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  7. Dual-phase contrast enhancement multi-slice CT in grading pancreatic neuroendocrine tumors

    International Nuclear Information System (INIS)

    Zhou Yan; Liu Jianyu; Zhu Xiang

    2013-01-01

    Objective: To evaluate characteristic clinical and imaging findings of pancreatic neuroendocrine tumors (NET) in dual-phase contrast enhancement MSCT. Methods: The dual-phase contrast enhancement MSCT images of 23 lesions in 20 patients with histologically confirmed pancreatic NET were studied retrospectively. Their clinical presentations, imaging characters as well as the intensities of lesions and normal pancreas in each phase were measured, and the following indices were calculated. First, the absolute enhancement of lesions, including the increasing of CT value of the maximum enhancement area within a tumor in arterial phase, that was named A1 in short, and that of the minimum enhancement area was labeled as A2. The same ROI measured increasing CT values in portal venous phase was labeled as V1 and V2 respectively. Secondly, the relatively enhancement indices comparing with the normal pancreas in the same patient within the same phase were calculated. This included the differences between the maximum, as well as the minimum, enhancement areas of tumors and the normal pancreas in arterial phase, which was named as AP1 and AP2 respectively, and those differences in portal venous phase, which were labeled as VP1 and VP2 respectively. All of the tumors were graded as G1 to G3 according to the WHO classification in 2010. A Kruskal Wallis test were performed to compare differences of tumor diameters and the enhancement indices. The change trend of enhancement indices varying with pathology grading were described. Fisher exact test was used to find differences of clinical and imaging characters. Results: Twenty-three lesions in 20 patients included 13 lesions in grade 1 (G1), 8 in G2, and 2 in G3. Among the 10 patients with G1 NET, 7 of them had no endocrine symptoms, while the other 3 had endocrine symptoms. Six of them had no abdominal pain, while 4 of them complained of it. All of the 10 patients with G1 NET had no hepatic metastasis. Among 8 patients with G2 NET

  8. Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI

    DEFF Research Database (Denmark)

    Rispoli, Vinicius C; Nielsen, Jon; Nayak, Krishna S

    2015-01-01

    BACKGROUND: Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dyn...

  9. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  10. Extraction of liver volumetry based on blood vessel from the portal phase CT dataset

    Science.gov (United States)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Utsunomiya, Tohru; Shimada, Mitsuo

    2012-02-01

    At liver surgery planning stage, the liver volumetry would be essential for surgeons. Main problem at liver extraction is the wide variability of livers in shapes and sizes. Since, hepatic blood vessels structure varies from a person to another and covers liver region, the present method uses that information for extraction of liver in two stages. The first stage is to extract abdominal blood vessels in the form of hepatic and nonhepatic blood vessels. At the second stage, extracted vessels are used to control extraction of liver region automatically. Contrast enhanced CT datasets at only the portal phase of 50 cases is used. Those data include 30 abnormal livers. A reference for all cases is done through a comparison of two experts labeling results and correction of their inter-reader variability. Results of the proposed method agree with the reference at an average rate of 97.8%. Through application of different metrics mentioned at MICCAI workshop for liver segmentation, it is found that: volume overlap error is 4.4%, volume difference is 0.3%, average symmetric distance is 0.7 mm, Root mean square symmetric distance is 0.8 mm, and maximum distance is 15.8 mm. These results represent the average of overall data and show an improved accuracy compared to current liver segmentation methods. It seems to be a promising method for extraction of liver volumetry of various shapes and sizes.

  11. Study of abdominal CT angiography in low tube voltage setting combined with personalized contrast media application

    International Nuclear Information System (INIS)

    Cao Jianxin; Wang Yiming; Zhang Yu; Tao Wei; Zhang Xiaodong; Wang Aijun; Liu Li; Wang Peng

    2012-01-01

    Objective: To investigate the feasibility of decreasing radiation dose and contrast media dose of abdominal CTA using low tube voltage setting combined with personalized contrast media application. Methods: One hundred and twenty patients were randomly divided into 3 groups, and there were 40 patients in each group. 120 kV tube voltage was used in group A, and 100 kV tube voltage was used in group B and C. Personalized injection flow rate of contrast media which determined according to patient's body mass (injection flow rate =λ × body mass) was used for all groups, and the λ values for group A, B and C were 0.07, 0.07 and 0.06 ml · kg -1 · s -1 respectively. CT dose index volume (CTDIvol) effective dose (ED) and contrast media dose were evaluated,and these parameters were all analyzed using one-way ANOVA analysis. Image quality of abdominal aorta and branch arteries was rated using a three-point ordinal for all 3 groups, and image quality score was analyzed using Kruskal-Wallis test. Results: CTDIvol were (8.2±0.8), (6.0 ±1.0) and (6.1 ±1.1)mGy for group A, B and C, ED were (5.2 ±0.8), (3.5 ± 0.7) and (3.6 ± 0.6) mSv, and contrast media dose were (72.3 ± 10.3),(73.5 ± 11.3) and (61.6 ±9.4) ml, respectively. There were significant differences in CTDIvol, ED and contrast media dose among 3 groups (F=66.094, 77.812,15.919; P=0.000). Compare with group A, the ED of group B was decreased 32.7%, and the ED and contrast media dose of group C were decreased 30.8% and 14.8%, respectively. Image quality was rated as excellent, good, and general for 20, 19 and 1 patients in group A, 25, 15 and 0 patients in group B, and 23, 17 and 0 patients in group C, respectively. There was no significant difference in image quality score among 3 groups (χ 2 =1.492, P=0.474). Conclusions: The radiation dose and contrast media dose can be decreased in abdominal CTA using low tube voltage and personalized contrast media application while image quality can be preserved

  12. Reduced iodinated contrast media for abdominal imaging by dual-layer spectral detector computed tomography for patients with kidney disease

    Directory of Open Access Journals (Sweden)

    Hirokazu Saito, MD

    2018-04-01

    Full Text Available Contrast-enhanced computed tomography using iodinated contrast media is useful for diagnosis of gastrointestinal diseases. However, contrast-induced nephropathy remains problematic for kidney diseases patients. Although current guidelines recommended the use of a minimal dose of contrast media necessary to obtain adequate images for diagnosis, obtaining adequate images with sufficient contrast enhancement is difficult with conventional computed tomography using reduced contrast media. Dual-layer spectral detector computed tomography enables the simultaneous acquisition of low- and high-energy data and the reconstruction of virtual monochromatic images ranging from 40 to 200 keV, retrospectively. Low-energy virtual monochromatic images can enhance the contrast of images, thereby facilitating reduced contrast media. In case 1, abdominal computed tomography angiography at 50 keV using 40% of the conventional dose of contrast media revealed the artery that was the source of diverticular bleeding in the ascending colon. In case 2, ischemia of the transverse colon was diagnosed by contrast-enhanced computed tomography and iodine-selective imaging using 40% of the conventional dose of contrast media. In case 3, advanced esophagogastric junctional cancer was staged and preoperative abdominal computed tomography angiography could be obtained with 30% of the conventional dose of contrast media. However, the texture of virtual monochromatic images may be a limitation at low energy. Keywords: Virtual monochromatic images, Contrast-induced nephropathy

  13. Application of phase contrast imaging to mammography

    International Nuclear Information System (INIS)

    Tohyama, Keiko; Yamada, Katsuhiko; Katafuchi, Tetsuro; Matsuo, Satoru; Morishita, Junji

    2005-01-01

    Phase contrast images were obtained experimentally by using a customized mammography unit with a nominal focal spot size of 100 μm and variable source-to-image distances of up to 1.5 m. The purpose of this study was to examine the applicability and potential usefulness of phase contrast imaging for mammography. A mammography phantom (ACR156 RMI phantom) was imaged, and its visibility was examined. The optical density of the phantom images was adjusted to approximately 1.3 for both the contact and phase contrast images. Forty-one observers (18 medical doctors and 23 radiological technologists) participated in visual evaluation of the images. Results showed that, in comparison with the images of contact mammography, the phantom images of phase contrast imaging demonstrated statistically significantly superior visibility for fibers, clustered micro-calcifications, and masses. Therefore, phase contrast imaging obtained by using the customized mammography unit would be useful for improving diagnostic accuracy in mammography. (author)

  14. Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

    International Nuclear Information System (INIS)

    Müller, Mark; Yaroshenko, Andre; Velroyen, Astrid; Tapfer, Arne; Bech, Martin; Pauwels, Bart; Bruyndonckx, Peter; Sasov, Alexander; Pfeiffer, Franz

    2015-01-01

    In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed

  15. Biological applications of phase-contrast electron microscopy.

    Science.gov (United States)

    Nagayama, Kuniaki

    2014-01-01

    Here, I review the principles and applications of phase-contrast electron microscopy using phase plates. First, I develop the principle of phase contrast based on a minimal model of microscopy, introducing a double Fourier-transform process to mathematically formulate the image formation. Next, I explain four phase-contrast (PC) schemes, defocus PC, Zernike PC, Hilbert differential contrast, and schlieren optics, as image-filtering processes in the context of the minimal model, with particular emphases on the Zernike PC and corresponding Zernike phase plates. Finally, I review applications of Zernike PC cryo-electron microscopy to biological systems such as protein molecules, virus particles, and cells, including single-particle analysis to delineate three-dimensional (3D) structures of protein and virus particles and cryo-electron tomography to reconstruct 3D images of complex protein systems and cells.

  16. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  17. X-ray phase-contrast imaging

    Science.gov (United States)

    Endrizzi, Marco

    2018-01-01

    X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of samples. It finds application in a vast diversity of fields: medicine, biology, many engineering disciplines, palaeontology and earth sciences are just few examples. The fundamental principle underpinning the image formation have remained the same for over a century: the X-rays traversing the sample are subjected to different amount of absorption in different parts of the sample. By means of phase-sensitive techniques it is possible to generate contrast also in relation to the phase shifts imparted by the sample and to extend the capabilities of X-ray imaging to those details that lack enough absorption contrast to be visualised in conventional radiography. A general overview of X-ray phase contrast imaging techniques is presented in this review, along with more recent advances in this fast evolving field and some examples of applications.

  18. Oral contrast for CT in patients with acute non-traumatic abdominal and pelvic pain: what should be its current role?

    Science.gov (United States)

    Kielar, Ania Z; Patlas, Michael N; Katz, Douglas S

    2016-10-01

    Positive oral contrast agents, including barium suspensions and water-soluble iodinated solutions, have traditionally been used in conjunction with the CT evaluation of patients with abdominal and pelvic pain. Due to continued advancements in CT technology, and due to increasing obesity and correspondingly a general increase in the intra-abdominal and intra-pelvic fat separating bowel loops in North American patients and in patients in other parts of the world over the past few decades, the ability of radiologists to accurately evaluate the cause of acute symptoms has substantially improved. Recent research and evolving imaging society guidelines/systematic reviews increasingly support performing CT scans of the abdomen and pelvis without the need for positive oral contrast in these types of adult patient populations, in most clinical situations. Increased patient throughput, patient preference, patient safety, and most importantly, retention of high diagnostic accuracy, are reasons for this recent change in practice to routinely omit the use of enteric contrast agents for the majority of patients presenting with acute abdominal and pelvic pain whom are undergoing emergency CT.

  19. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  20. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  1. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  2. Staged abdominal re-operation for abdominal trauma.

    Science.gov (United States)

    Taviloglu, Korhan

    2003-07-01

    To review the current developments in staged abdominal re-operation for abdominal trauma. To overview the steps of damage control laparotomy. The ever increasing importance of the resuscitation phase with current intensive care unit (ICU) support techniques should be emphasized. General surgeons should be familiar to staged abdominal re-operation for abdominal trauma and collaborate with ICU teams, interventional radiologists and several other specialties to overcome this entity.

  3. Laser projection using generalized phase contrast

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin; Rodrigo, Peter John

    2007-01-01

    is introduced. An arbitrary phase shift filter eliminates the need for high-frequency modulation and conjugate phase encoding. This lowers device performance requirements and allows practical implementation with currently available dynamic spatial light modulators. (c) 2007 Optical Society of America.......We demonstrate experimental laser projection of a gray-level photographic image with 74% light efficiency using the generalized phase contrast (GPC) method. In contrast with a previously proposed technique [Alonzo et al., New J. Phys. 9, 132 (2007)], a new approach to image construction via GPC...

  4. High spatial resolution magnetic resonance imaging of experimental cerebral venous thrombosis with a blood pool contrast agent

    International Nuclear Information System (INIS)

    Spuentrup, E.; Wiethoff, A.J.; Parsons, E.C.; Spangenberg, P.; Stracke, C.P.

    2010-01-01

    Purpose: The purpose of this study was to investigate the feasibility of clot visualization in small sinus and cortical veins with contrast enhanced MRA in a cerebral venous thrombosis animal model using a blood pool contrast agent, Gadofosveset, and high spatial resolution imaging. Material and methods: For induction of cerebral venous thrombosis a recently developed combined interventional and microsurgical model was used. Cerebral sinus and cortical vein thrombosis was induced in six pigs. Two further pigs died during the procedure. Standard structural, time-of-flight- and phase contrast-angiograms were followed by fast time resolved high resolution 3D MRA (4D MRA) and subsequent high spatial resolution 3D MRA in the equilibrium phase with and without addition of parallel imaging. Visualization of the clots using the different sequences was subjectively compared and contrast-to-noise ratio (CNR) was assessed. Results: In the remaining six animals the procedure and MR-imaging protocol including administration of Gadofosveset was successfully completed. The 3D high resolution MRA in the equilibrium phase without the addition of parallel imaging was superior to all the other applied MR measurement techniques in terms of visualization of the clots. Only applying this sequence bridging vein thromboses were also seen as a small filling defect with a high CNR of >18. Conclusion: Only the non-accelerated high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset allows for high-contrast visualization of very small clots in the cerebral sinus and cortical veins. Statement clinical impact: Detection of cortical vein thrombosis is of high clinical impact. Conventional MRI sequences often fail to visualize the clot. We could demonstrate that, in contrast to conventional sequences, with high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset very small clots in the cerebral sinus and

  5. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent.

    Science.gov (United States)

    Jenjob, Ratchapol; Kun, Na; Ghee, Jung Yeon; Shen, Zheyu; Wu, Xiaoxia; Cho, Steve K; Lee, Don Haeng; Yang, Su-Geun

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd(3+), chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd(3+) in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd(3+) incubated with Ca(2+) was performed by using a dialysis membrane (MWCO 100-500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd(3+), the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd(3+) were released from Gd-DTPA-Pullulan after 2h incubation with Ca(2+) and Fe(2+), respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t1/2,α=0.43 h, t1/2,β=2.32 h), much longer than 0.11h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    Science.gov (United States)

    Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu

    2015-01-01

    To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  7. Feasibility Study of Using Gemstone Spectral Imaging (GSI and Adaptive Statistical Iterative Reconstruction (ASIR for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    Directory of Open Access Journals (Sweden)

    Zheng Zhu

    Full Text Available To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI and adaptive statistical iterative reconstruction (ASIR for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values.26 patients (weight > 65kg and BMI ≥ 22 underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A. Another 21 patients (weight ≤ 65kg and BMI ≥ 22 were scanned with a conventional 120 kVp tube voltage for noise index (NI of 11 with 450mgI/kg contrast material as control group (group B. GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD, signal-noise-ratio (SNR, contrast-noise-ratio (CNR of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis.As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684. CT dose index (CTDI values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000, respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B.The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  8. Low density contrast agents for x-ray phase contrast imaging: the use of ambient air for x-ray angiography of excised murine liver tissue

    International Nuclear Information System (INIS)

    Laperle, Christopher M; Wintermeyer, Philip; Derdak, Zoltan; Wands, Jack R; Hamilton, Theron J; Walker, Evan J; Diebold, Gerald; Rose-Petruck, Christoph; Shi, Daxin; Anastasio, Mark A

    2008-01-01

    We report a new preparative method for providing contrast through reduction in electron density that is uniquely suited for propagation-based differential x-ray phase contrast imaging. The method, which results in an air or fluid filled vasculature, makes possible visualization of the smallest microvessels, roughly down to 15 μm, in an excised murine liver, while preserving the tissue for subsequent histological workup. We show the utility of spatial frequency filtering for increasing the visibility of minute features characteristic of phase contrast imaging, and the capability of tomographic reconstruction to reveal microvessel structure and three-dimensional visualization of the sample. The effect of water evaporation from livers during x-ray imaging on the visibility of blood vessels is delineated. The deformed vascular tree in a cancerous murine liver is imaged.

  9. The assessment of the breath hold and the free breath methods about the blood flow evaluation by using phase contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Ho [Dept. of Radiology, Konkuk Medical center, Seoul (Korea, Republic of)

    2016-06-15

    Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/ velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were 96.17±19.12 ml/sec, 17.04±4.12 cm/sec respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of 72.31±13.27 ml and 12.32±3.85. On the other hand, the average 2NEX blood flow and mean flow velocity is 101.90±24.09, 16.84±4.32, 3NEX 103.06±25.49, 16.88±4.19 did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were 76.68±19.72 ml/s, and 22.23±4.8, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

  10. Phase contrast STEM for thin samples: Integrated differential phase contrast.

    Science.gov (United States)

    Lazić, Ivan; Bosch, Eric G T; Lazar, Sorin

    2016-01-01

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). Copyright © 2015 Elsevier B.V. All rights reserved.

  11. X-ray phase contrast with injected gas for tumor microangiography

    International Nuclear Information System (INIS)

    Lundström, U; Larsson, D H; Burvall, A; Hertz, H M; Westermark, U K; Henriksson, M Arsenian

    2014-01-01

    We show that the microvasculature of mouse tumors can be visualized using propagation-based phase-contrast x-ray imaging with gas as the contrast agent. The large density difference over the gas–tissue interface provides high contrast, allowing the imaging of small-diameter blood vessels with relatively short exposure times and low dose using a compact liquid-metal-jet x-ray source. The method investigated is applied to tumors (E1A/Ras-transformed mouse embryonic fibroblasts) grown in mouse ears, demonstrating sub-15-µm-diameter imaging of their blood vessels. The exposure time for a 2D projection image is a few seconds and a full tomographic 3D map takes some minutes. The method relies on the strength of the vasculature to withstand the gas pressure. Given that tumor vessels are known to be more fragile than normal vessels, we investigate the tolerance of the vasculature of 12 tumors to gas injection and find that a majority withstand 200 mbar pressures, enough to fill 12-µm-diameter vessels with gas. A comparison of the elasticity of tumorous and non-tumorous vessels supports the assumption of tumor vessels being more fragile. Finally, we conclude that the method has the potential to be extended to the imaging of 15 µm vessels in thick tissue, including mouse imaging, making it of interest for, e.g., angiogenesis research. (paper)

  12. Quando a fase de equilíbrio pode ser suprimida nos exames de tomografia computadorizada de abdome? What is the real role of the equilibrium phase in abdominal computed tomography?

    Directory of Open Access Journals (Sweden)

    Priscila Silveira Salvadori

    2013-04-01

    Full Text Available OBJETIVO: Avaliar a necessidade de realização da fase de equilíbrio nos exames de tomografia computadorizada de abdome. MATERIAIS E MÉTODOS: Realizou-se estudo retrospectivo, transversal e observacional, avaliando 219 exames consecutivos de tomografia computadorizada de abdome com contraste intravenoso, realizados num período de três meses, com diversas indicações clínicas. Para cada exame foram emitidos dois pareceres, um avaliando o exame sem a fase de equilíbrio (primeira análise e o outro avaliando todas as fases em conjunto (segunda análise. Ao final de cada avaliação, foi estabelecido se houve mudança nos diagnósticos principais e secundários, entre a primeira e a segunda análise. Foi utilizada a extensão do teste exato de Fisher para avaliar a modificação dos diagnósticos principais (p 0,999. Com relação aos diagnósticos secundários, cinco exames (2,3% foram modificados. CONCLUSÃO: Para indicações clínicas como estadiamento tumoral, abdome agudo e pesquisa de coleção abdominal, a fase de equilíbrio não acrescenta contribuição diagnóstica expressiva, podendo ser suprimida dos protocolos de exame.OBJECTIVE: To evaluate the role of the equilibrium phase in abdominal computed tomography. MATERIALS AND METHODS: A retrospective, cross-sectional, observational study reviewed 219 consecutive contrast-enhanced abdominal computed tomography images acquired in a three-month period, for different clinical indications. For each study, two reports were issued - one based on the initial analysis of non-contrast-enhanced, arterial and portal phases only (first analysis, and a second reading of these phases added to the equilibrium phase (second analysis. At the end of both readings, differences between primary and secondary diagnoses were pointed out and recorded, in order to measure the impact of suppressing the equilibrium phase on the clinical outcome for each of the patients. The extension of the exact Fisher

  13. X-ray Phase Contrast analysis - Digital wavefront development

    International Nuclear Information System (INIS)

    Idir, Mourad; Potier, Jonathan; Fricker, Sebastien; Snigirev, Anatoly; Snigireva, Irina; Modi, M. H.

    2010-01-01

    Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

  14. Isotropic differential phase contrast microscopy for quantitative phase bio-imaging.

    Science.gov (United States)

    Chen, Hsi-Hsun; Lin, Yu-Zi; Luo, Yuan

    2018-05-16

    Quantitative phase imaging (QPI) has been investigated to retrieve optical phase information of an object and applied to biological microscopy and related medical studies. In recent examples, differential phase contrast (DPC) microscopy can recover phase image of thin sample under multi-axis intensity measurements in wide-field scheme. Unlike conventional DPC, based on theoretical approach under partially coherent condition, we propose a new method to achieve isotropic differential phase contrast (iDPC) with high accuracy and stability for phase recovery in simple and high-speed fashion. The iDPC is simply implemented with a partially coherent microscopy and a programmable thin-film transistor (TFT) shield to digitally modulate structured illumination patterns for QPI. In this article, simulation results show consistency of our theoretical approach for iDPC under partial coherence. In addition, we further demonstrate experiments of quantitative phase images of a standard micro-lens array, as well as label-free live human cell samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Proposed protocol for realization of abdominal CT in patients admitted to the emergency room for trauma in HSJD

    International Nuclear Information System (INIS)

    Quesada Cascante, Lizbeth

    2013-01-01

    A protocol is established for computed tomography in trauma patients treated in emergency of Hospital San Juan de Dios. A literature review is conducted on abdominal CT protocols in specialized databases. The criteria, scanning, parameters and delay time are established for realization of abdominal CT in patients with traumatic emergencies in HSJD. Taking the thickness of the sections, the thickness of the sections in reconstruction, the quantities of contrast and the speed of injection in patients, have been standardized for the realization of abdominal CT in HSJD. Computed tomography should be preferably performed of routine in portal phase and the late from 5 minutes in patients with abdominal trauma, contributing in this phase as much information regarding the extent of abdominal injury [es

  16. Association between general and abdominal obesity with high blood pressure: difference between genders.

    Science.gov (United States)

    Silva, Alison O; Silva, Micaelly V; Pereira, Lisley K N; Feitosa, Wallacy M N; Ritti-Dias, Raphael M; Diniz, Paula R B; Oliveira, Luciano M F T

    2016-01-01

    To assess the association between general and abdominal obesity with high blood pressure in adolescents of both genders from the public school system. This was an epidemiological, descriptive, exploratory study, with a quantitative approach and local scope whose sample consisted of 481 high school students (aged 14-19), selected by using a random cluster sampling strategy. Blood pressure was measured through the use of automated monitor and was considered high when the pressure values were at or above the 95th percentile. The analyses were performed using the chi-squared test and binary logistic regression. The prevalence of high blood pressure was 6.4%, and it was higher among boys (9.0% vs. 4.7%, phigh blood pressure was associated with general (OR=6.4; phigh blood pressure only in boys, regardless of age. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  17. IMAGING DIAGNOSIS-ECTOPIC SPLEEN MIMICKING HEPATIC TUMOR WITH INTRA-ABDOMINAL METASTASES INVESTIGATED VIA TRIPLE-PHASE HELICAL COMPUTED TOMOGRAPHY IN A DOG.

    Science.gov (United States)

    Kutara, Kenji; Konno, Toshiaki; Kondo, Hirotaka; Aoki, Kotoyo; Yamazoe, Hinako; Matsunaga, Satoru

    2017-05-01

    A 10-year-old castrated male miniature dachshund was presented with an abdominal mass. The dog had a history of splenectomy. Triple-phase helical computed tomography was utilized, revealing a hepatic mass and multiple intra-abdominal solid masses. In triple-phase helical computed tomography the images, hepatic mass and two of four intra-abdominal masses were heterogenous in all phases. Therefore, we diagnosed a malignant hepatic tumor and presumed intra-abdominal metastases. The masses were surgically removed and were histologically composed of normal spleen tissues, findings which were consistent with ectopic spleen. © 2016 American College of Veterinary Radiology.

  18. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  19. Phase retrieval for X-ray in-line phase contrast imaging

    International Nuclear Information System (INIS)

    Scattarella, F.; Bellotti, R.; Tangaro, S.; Gargano, G.; Giannini, C.

    2011-01-01

    A review article about phase retrieval problem in X-ray phase contrast imaging is presented. A simple theoretical framework of Fresnel diffraction imaging by X-rays is introduced. A review of the most important methods for phase retrieval in free-propagation-based X-ray imaging and a new method developed by our collaboration are shown. The proposed algorithm, Combined Mixed Approach (CMA) is based on a mixed transfer function and transport of intensity approach, and it requires at most an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy with which this initial estimate is known determines the convenience speed of algorithm. The new proposed algorithm is based on the retrieval of both the object phase and its complex conjugate. The results obtained by the algorithm on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The algorithm was also tested on noisy experimental phase contrast data, showing a good efficiency in recovering phase information and enhancing the visibility of details inside soft tissues.

  20. Bi-directional x-ray phase-contrast mammography.

    Directory of Open Access Journals (Sweden)

    Kai Scherer

    Full Text Available Phase-contrast x-ray imaging is a promising improvement of conventional absorption-based mammography for early tumor detection. This potential has been demonstrated recently, utilizing structured gratings to obtain differential phase and dark-field scattering images. However, the inherently anisotropic imaging sensitivity of the proposed mono-directional approach yields only insufficient diagnostic information, and has low diagnostic sensitivity to highly oriented structures. To overcome these limitations, we present a two-directional x-ray phase-contrast mammography approach and demonstrate its advantages by applying it to a freshly dissected, cancerous mastectomy breast specimen. We illustrate that the two-directional scanning procedure overcomes the insufficient diagnostic value of a single scan, and reliably detects tumor structures, independently from their orientation within the breast. Our results indicate the indispensable diagnostic necessity and benefit of a multi-directional approach for x-ray phase-contrast mammography.

  1. Abdominal aspergillosis: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Suk Keu, E-mail: pagoda20@hanmail.net [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Hye Jin, E-mail: kimhyejin@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Byun, Jae Ho, E-mail: jhbyun@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Ah Young, E-mail: aykim@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Lee, Moon-Gyu, E-mail: mglee@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Ha, Hyun Kwon, E-mail: hkha@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2011-03-15

    Objective: In order to retrospectively evaluate the CT findings of abdominal aspergillosis in immunocompromised patients. Materials and methods: CT scans were reviewed with regard to the sites, number, morphologic appearance, attenuation, and the contrast enhancement patterns of the lesions in six patients (5 women, 1 man; mean age, 43.4 years; range, 23-59 years) with pathologically proved abdominal aspergillosis by two gastrointestinal radiologists in consensus. Medical records were also reviewed to determine each patient's clinical status and outcome. Results: All patients were immunocompromised state: 4 patients received immunosuppressive therapy for solid organ transplantation and 2 patients received chemotherapy for acute myeloid leukemia. Aspergillosis involved blood vessels (n = 3), liver (n = 2), spleen (n = 2), gastrointestinal tract (n = 2), native kidney (n = 1), transplanted kidney (n = 1), peritoneum (n = 1), and retroperitoneum (n = 1). CT demonstrated solid organ or bowel infarction or perforation secondary to vascular thrombosis or pseudoaneurysm, multiple low-attenuating lesions of solid organs presenting as abscesses, concentric bowel wall thickening mimicking typhlitis, or diffuse or nodular infiltration of the peritoneum and retroperitoneum. Conclusion: Familiarity with findings commonly presenting as angioinvasive features or abscesses on CT, may facilitate the diagnosis of rare and fatal abdominal aspergillosis.

  2. Visceral adiposity, not abdominal subcutaneous fat area, is associated with high blood pressure in Japanese men. The Ohtori study

    International Nuclear Information System (INIS)

    Koh, Hideo; Hayashi, Tomoshige; Kogawa Sato, Kyoko

    2011-01-01

    Visceral adiposity is considered to have a key role in cardiometabolic diseases. The purpose of this study is to investigate cross-sectionally the association between intra-abdominal fat area (IAFA) measured by computed tomography (CT) and high blood pressure independent of abdominal subcutaneous fat area (ASFA) and insulin resistance. Study participants included 624 Japanese men not taking oral hypoglycemic medications or insulin. Abdominal, thoracic and thigh fat areas were measured by CT. Total fat area (TFA) was calculated as the sum of abdominal, thoracic and thigh fat area. Total subcutaneous fat area (TSFA) was defined as TFA minus IAFA. Hypertension and high normal blood pressure were defined using the 1999 criteria of the World Health Organization. Multiple-adjusted odds ratios of hypertension for tertiles of IAFA were 2.64 (95% confidence interval, 1.35-5.16) for tertile 2, and 5.08 (2.48-10.39) for tertile 3, compared with tertile 1 after adjusting for age, fasting immunoreactive insulin, diabetes status, ASFA, alcohol consumption, regular physical exercise and smoking habit. IAFA remained significantly associated with hypertension even after adjustment for ASFA, TSFA, TFA, body mass index or waist circumference, and no other measure of regional or total adiposity was associated with the odds of hypertension in models, which included IAFA. Similar results were obtained for the association between IAFA and the prevalence of high normal blood pressure or hypertension. In conclusion, greater visceral adiposity was associated with a higher odds of high blood pressure in Japanese men. (author)

  3. Contrast-enhanced 3D MR angiography of the chest and abdomen with breath-holding using phase reordering

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Sugimoto, Eiichi; Enomoto, Kyoko; Watabe, Tsuneya; Heshiki, Atsuko; Hirata, Hisashi; Kimura, Toshihiko; Takizawa, Osamu.

    1995-01-01

    This report presents the feasibility of phase-reordered contrast-enhanced three-dimensional MR angiography in 32 consecutive patients with vascular abnormalities in the chest and abdomen. To suppress motion artifacts due to respiratory corruption, a phase-reordering technique was introduced so that the low frequency components of the phase data were obtained first during the imaging period. Image quality and degree of motion suppression were assessed by four radiologists independently without information on breath-holding time. Abnormalities were detected in 30 cases (93.8%), and their extent was correctly assessed in 28 cases (87.5%). More confident assessment was possible in abnormalities of the pulmonary vessels and thoracic aorta than in those of the abdominal aorta and portal venous system. With phase reordering, more than 20 seconds of breath-holding ensured image quality sufficient to correctly assess the vascular abnormalities. While this technique is easy and requires only single breath-holding, it can provide excellent MRA without slice-to-slice spatial misregistration. (author)

  4. Systolically gated 3D phase contrast MRA of mesenteric arteries in suspected mesenteric ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Wasser, M.N.; Schultze Kool, L.J.; Roos, A. de [Leiden Univ. Hospital (Netherlands)] [and others

    1996-03-01

    Our goal was to assess the value of MRA for detecting stenoses in the celiac (CA) and superior mesenteric (SMA) arteries in patients suspected of having chronic mesenteric ischemia, using an optimized systolically gated 3D phase contrast technique. In an initial study in 24 patients who underwent conventional angiography of the abdominal vessels for different clinical indications, a 3D phase contrast MRA technique (3D-PCA) was evaluated and optimized to image the CAs and SMAs. Subsequently, a prospective study was performed to assess the value of systolically gated 3D-PCA in evaluation of the mesenteric arteries in 10 patients with signs and symptoms of chronic mesenteric ischemia. Intraarterial digital subtraction angiography and surgical findings were used as the reference standard. In the initial study, systolic gating appeared to be essential in imaging the SMA on 3D-PCA. In 10 patients suspected of mesenteric ischemia, systolically gated 3D-PCA identified significant proximal disease in the two mesenteric vessels in 4 patients. These patients underwent successful reconstruction of their stenotic vessels. Cardiac-gated MRA may become a useful tool in selection of patients suspected of having mesenteric ischemia who may benefit from surgery. 16 refs., 6 figs., 4 tabs.

  5. Subcutaneous blood flow in man during sleep with continous epdural anaesthesia

    DEFF Research Database (Denmark)

    Sindrup, JH; Petersen, Lars Jelstrup; Kastrup, Jens

    1996-01-01

    BACKGROUND: Subcutaneous blood flow increases during sleep and we evaluated if this increase is affected by epidural anaesthesia. METHODS: Lower leg subcutaneous blood flow was determined by 133Xenon clearance in ten subjects during continous epidural anaesthesia at L2-L3 including eight hours...... of sleep, while the opper abdominal subcutaneous blood flow served as control. RESULTS: Epidural anaesthesia to the level of the umbilicus was followed by an increase in the lower leg subcutaneous blood flow fra 3.4 (1.8-6.3) to 7.8 (3.6-16.9) ml min-1 (median and range; P....4-7.6) ml min-1 100 g-1 after 88 (45-123) min. In contrast, until the period of sleep the upper abdominal region blood flow remained at 5.2 (3.2-6.4) ml min-1 100 g-1. During sleep, lower leg subcutaneous blood flow did not change significantly, but the upper abdominal flow increased to 6.2 (5.2-7.2) ml min...

  6. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    Science.gov (United States)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  7. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  8. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  9. Self-Assembled Nanomicelles as MRI Blood-Pool Contrast Agent.

    Science.gov (United States)

    Babič, Andrej; Vorobiev, Vassily; Xayaphoummine, Céline; Lapicorey, Gaëlle; Chauvin, Anne-Sophie; Helm, Lothar; Allémann, Eric

    2018-01-26

    Gadolinium-loaded nanomicelles show promise as future magnetic resonance imaging (MRI) contrast agents (CAs). Their increased size and high gadolinium (Gd) loading gives them an edge in proton relaxivity over smaller molecular Gd-complexes. Their size and stealth properties are fundamental for their long blood residence time, opening the possibility for use as blood-pool contrast agents. Using l-tyrosine as a three-functional scaffold we synthesized a nanostructure building block 8. The double C18 aliphatic chain on one side, Gd-1,4,7,10-tetraazacyclododecane-1-4-7-triacetic acid (Gd-DO3A) with access to bulk water in the center and 2 kDa PEG on the hydrophilic side gave the amphiphilic properties required for the core-shell nanomicellar architecture. The self-assembly into Gd-loaded monodispersed 10-20 nm nanomicelles occurred spontaneously in water. These nanomicelles (Tyr-MRI) display very high relaxivity at 29 mm -1  s -1 at low field strength and low cytotoxicity. Good contrast enhancement of the blood vessels and the heart together with prolonged circulation time in vivo, makes Tyr-MRI an excellent candidate for a new supramolecular blood-pool MRI CA. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    the contrast medium can escape from the vessels into the parenchyma, which causes an enhancement or a free space in lesions of the brain. Due to the good blood flow in the abdominal organs, it is necessary to administer 3 ml of contrast medium per kg, the flow should be 1 - 2 ml/s depending on the size of the animal. 15 seconds after beginning of bolus the aorta shows a maximum of enhancement, the abdominal organs show their maximum a little later. Therefore it is necessary to begin examination during the application of bolus, so that the arterial phase of the enhancement can be used. This study is the basis for other studies on contrast enhancement of soft tissues. Veterinary diagnosis should not solely be based on human medicine studies and experiences. (author)

  12. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    the contrast medium can escape from the vessels into the parenchyma, which causes an enhancement or a free space in lesions of the brain. Due to the good blood flow in the abdominal organs, it is necessary to administer 3 ml of contrast medium per kg, the flow should be 1 - 2 ml/s depending on the size of the animal. 15 seconds after beginning of bolus the aorta shows a maximum of enhancement, the abdominal organs show their maximum a little later. Therefore it is necessary to begin examination during the application of bolus, so that the arterial phase of the enhancement can be used. This study is the basis for other studies on contrast enhancement of soft tissues. Veterinary diagnosis should not solely be based on human medicine studies and experiences. (author)

  13. An 88-Year-Old Man with Sudden Onset Abdominal Pain

    Directory of Open Access Journals (Sweden)

    Mohammad Manouchehrifar

    2015-07-01

    Full Text Available An 88-year-old man presented to the emergency department with sudden onset of abdominal pain since 6 hours before. He was a known case of chronic renal failure that underwent hemodialysis three times a week. He also suffered from hypertension and benign prostatic hyperplasia. The patients’ on-arrival vital signs were as follows: systolic blood pressure: 100/60 mmHg, pulse rate: 88/minute, respiratory rate: 25/minute, oral temperature: 36◦C, oxygen saturation 93% in room air.  He had severely ill appearance on admission. Distended abdomen was considerable but had normal bowel sound and clearly, pain was disproportionate to physical examination. His electrocardiogram showed sinus rhythm and venous blood gas analysis revealed the following: pH=6.96, PaCO2=49 mmHg, HCO3=11 mEq/L, Base excess= -20.  The bedside ultrasonography showed echogenic particles in hepatic parenchyma and same findings that were passing through the portal vein. Chest and abdominal X-rays were reported as normal. The patient underwent abdominal and pelvic computed tomography (CT scan with oral contrast.What is your diagnosis?

  14. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  15. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  16. Spline based iterative phase retrieval algorithm for X-ray differential phase contrast radiography.

    Science.gov (United States)

    Nilchian, Masih; Wang, Zhentian; Thuering, Thomas; Unser, Michael; Stampanoni, Marco

    2015-04-20

    Differential phase contrast imaging using grating interferometer is a promising alternative to conventional X-ray radiographic methods. It provides the absorption, differential phase and scattering information of the underlying sample simultaneously. Phase retrieval from the differential phase signal is an essential problem for quantitative analysis in medical imaging. In this paper, we formalize the phase retrieval as a regularized inverse problem, and propose a novel discretization scheme for the derivative operator based on B-spline calculus. The inverse problem is then solved by a constrained regularized weighted-norm algorithm (CRWN) which adopts the properties of B-spline and ensures a fast implementation. The method is evaluated with a tomographic dataset and differential phase contrast mammography data. We demonstrate that the proposed method is able to produce phase image with enhanced and higher soft tissue contrast compared to conventional absorption-based approach, which can potentially provide useful information to mammographic investigations.

  17. Tuberculosis versus lymphoma in the abdominal lymph nodes: A comparative study using contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Shao, Heng; Yang, Zhi-gang; Deng, Wen; Chen, Jing; Tang, Si-shi; Wen, Ling-yi

    2012-01-01

    Purpose: The purpose of this study was to determine the differential characteristics on MRI between tuberculosis and lymphoma in abdominal lymph nodes. Materials and methods: We conducted a retrospective analysis for the counter, size, signal intensity, enhancement patterns, and anatomic distribution of lymph nodes in 57 consecutive patients with documented tuberculosis (28 patients; 49.1%) and newly diagnosed, untreated lymphoma (29 patients; 50.9%). Results: Twenty-four cases (85.7%) in the tuberculosis group were hyperintense on T2-weighted images and either hypointense or isointense on T1-weighted images with respect to the abdominal wall muscle. All cases in the lymphoma group were hyperintense on T2-weighted images and isointense on T1-weighted images with respect to the abdominal wall muscle. Concerning the main anatomic distribution of lymph nodes, the lymph nodes in the lower paraaortic region were more frequently involved in the lymphoma group (48.3%) than in tuberculosis (17.9%, p < 0.05). Moreover, mesenteric lymph nodes were more often involved in tuberculosis (32.1%) than in lymphoma (6.9%, p < 0.05). Tuberculous lymphadenopathy showed predominantly peripheral enhancement, frequently with a multilocular appearance; whereas lymphomatous adenopathy often demonstrated uniform homogeneous enhancement (all p < 0.001). Conclusion: Contrast-enhanced MRI can be useful in differentiation between these two entities

  18. Comparing Measures of General and Abdominal Adiposity as Predictors of Blood Pressure in College Students

    Science.gov (United States)

    Abshire, Demetrius A.; Mudd-Martin, Gia; Moser, Debra K.; Lennie, Terry A.

    2018-01-01

    Objective: To compare anthropometric measures of body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR), and sagittal abdominal diameter (SAD) as predictors of blood pressure in college students. Participants: Students (N = 116) were recruited from November 2012 to May 2014 at an urban university and rural community…

  19. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  20. Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

    Science.gov (United States)

    Basha, Tamer A; Akçakaya, Mehmet; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    2015-01-01

    The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Menk, Ralf Hendrik

    2008-01-01

    All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift φ directly (using interference phenomena), the gradient ∇ φ , or the Laplacian ∇ 2 φ. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy

  2. Phase contrast STEM for thin samples: Integrated differential phase contrast

    International Nuclear Information System (INIS)

    Lazić, Ivan; Bosch, Eric G.T.; Lazar, Sorin

    2016-01-01

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). - Highlights: • First DPC-based atomic resolution images of potential and charge density are obtained. • This is enabled by integration and differentiation of 2D DPC signals, respectively. • Integrated DPC (iDPC) based on 4 quadrant imaging is compared to iCOM imaging. • Noise analysis and comparison with standard STEM imaging modes is provided. • iDPC allows direct imaging of light (C, N, O …) and heavy (Ga, Au …) atoms together.

  3. Phase contrast STEM for thin samples: Integrated differential phase contrast

    Energy Technology Data Exchange (ETDEWEB)

    Lazić, Ivan, E-mail: ivan.lazic@fei.com; Bosch, Eric G.T.; Lazar, Sorin

    2016-01-15

    It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). - Highlights: • First DPC-based atomic resolution images of potential and charge density are obtained. • This is enabled by integration and differentiation of 2D DPC signals, respectively. • Integrated DPC (iDPC) based on 4 quadrant imaging is compared to iCOM imaging. • Noise analysis and comparison with standard STEM imaging modes is provided. • iDPC allows direct imaging of light (C, N, O …) and heavy (Ga, Au …) atoms together.

  4. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  5. Image fusion in x-ray differential phase-contrast imaging

    Science.gov (United States)

    Haas, W.; Polyanskaya, M.; Bayer, F.; Gödel, K.; Hofmann, H.; Rieger, J.; Ritter, A.; Weber, T.; Wucherer, L.; Durst, J.; Michel, T.; Anton, G.; Hornegger, J.

    2012-02-01

    Phase-contrast imaging is a novel modality in the field of medical X-ray imaging. The pioneer method is the grating-based interferometry which has no special requirements to the X-ray source and object size. Furthermore, it provides three different types of information of an investigated object simultaneously - absorption, differential phase-contrast and dark-field images. Differential phase-contrast and dark-field images represent a completely new information which has not yet been investigated and studied in context of medical imaging. In order to introduce phase-contrast imaging as a new modality into medical environment the resulting information about the object has to be correctly interpreted. The three output images reflect different properties of the same object the main challenge is to combine and visualize these data in such a way that it diminish the information explosion and reduce the complexity of its interpretation. This paper presents an intuitive image fusion approach which allows to operate with grating-based phase-contrast images. It combines information of the three different images and provides a single image. The approach is implemented in a fusion framework which is aimed to support physicians in study and analysis. The framework provides the user with an intuitive graphical user interface allowing to control the fusion process. The example given in this work shows the functionality of the proposed method and the great potential of phase-contrast imaging in medical practice.

  6. Experimental validation of the Wigner distributions theory of phase-contrast imaging

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2005-01-01

    Recently, a new theory of phase-contrast imaging has been proposed by Wu and Liu [Med. Phys. 31, 2378-2384 (2004)]. This theory, based upon Wigner distributions, provides a much stronger foundation for the evaluation of phase-contrast imaging systems than did the prior theories based upon Fresnel-Kirchhoff diffraction theory. In this paper, we compare results of measurements made in our laboratory of phase contrast for different geometries and tube voltages to the predictions of the Wu and Liu model. In our previous publications, we have used an empirical measurement (the edge enhancement index) to parametrize the degree of phase-contrast effects in an image. While the Wu and Liu model itself does not predict image contrast, it does measure the degree of phase contrast that the system can image for a given spatial frequency. We have found that our previously published experimental results relating phase-contrast effects to geometry and x-ray tube voltage are consistent with the predictions of the Wu and Liu model

  7. Phase-only optical encryption based on the zeroth-order phase-contrast technique

    Science.gov (United States)

    Pizolato, José Carlos; Neto, Luiz Gonçalves

    2009-09-01

    A phase-only encryption/decryption scheme with the readout based on the zeroth-order phase-contrast technique (ZOPCT), without the use of a phase-changing plate on the Fourier plane of an optical system based on the 4f optical correlator, is proposed. The encryption of a gray-level image is achieved by multiplying the phase distribution obtained directly from the gray-level image by a random phase distribution. The robustness of the encoding is assured by the nonlinearity intrinsic to the proposed phase-contrast method and the random phase distribution used in the encryption process. The experimental system has been implemented with liquid-crystal spatial modulators to generate phase-encrypted masks and a decrypting key. The advantage of this method is the easy scheme to recover the gray-level information from the decrypted phase-only mask applying the ZOPCT. An analysis of this decryption method was performed against brute force attacks.

  8. Reconstruction methods for phase-contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raven, C.

    1997-02-01

    Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of a reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.

  9. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Shirai, Ryota; Kunii, Takuya; Yoneyama, Akio; Ooizumi, Takahito; Maruyama, Hiroko; Lwin, Thet Thet; Hyodo, Kazuyuki; Takeda, Tohoru

    2014-07-01

    Phase-contrast X-ray imaging using a crystal X-ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase-contrast X-ray system was used, fitted with a two-crystal X-ray interferometer at 35 keV X-ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol-fixed kidney could be visualized more clearly than that of formalin-fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol-fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7-3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol-fixation technique enables the image contrast to be enhanced in phase-contrast X-ray imaging.

  10. ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.

    Science.gov (United States)

    Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison

    2015-01-01

    Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.

  11. X-ray phase-contrast tomosynthesis for improved breast tissue discrimination

    International Nuclear Information System (INIS)

    Schleede, Simone; Bech, Martin; Grandl, Susanne; Sztrókay, Aniko; Herzen, Julia; Mayr, Doris; Stockmar, Marco; Potdevin, Guillaume

    2014-01-01

    Purpose: Attenuation-based tomosynthesis has proven to successfully resolve the glandular tissue overlap present in mammography. However, the ability of tomosynthesis to differentiate tumorous and glandular tissue remains limited, due to the small differences in X-ray attenuation in breast tissue. One possibility to overcome this limitation and to further increase the diagnostic value of tomosynthesis exams, is the application of recently developed grating-based phase-contrast methods, which provide complementary information on the phase shift and the local scattering power of the sample. In this study, we report on first phase-contrast breast tomosynthesis results of a mastectomy sample slice with an invasive ductal carcinoma. Material and methods: A slice of a mastectomy sample with histologically proven invasive ductal cancer was imaged at the synchrotron radiation source ESRF (Grenoble, France). We used a two-grating interferometer setup at the ninth fractional Talbot distance and with an X-ray energy of 23 keV. In grating interferometry absorption, differential phase, and scattering images are recorded simultaneously. The tomosynthesis scan comprises 61 projections. Multimodal tomosynthesis results were reconstructed using a standard filtered back-projection approach. Our findings are supported by a comparison of tomographic views to histopathology. Results: Phase-contrast tomosynthesis combines the advantage of improved soft-tissue discrimination in phase-contrast imaging with the ability of tomosynthesis to provide a third dimension so that improved feature visibility is not hampered by superposition artifacts. Our results indicate superior diagnostic value due to the depth resolution supplied in tomosynthesis imaging; a region of necrotic tissue that is obscured in a projection image can clearly be depicted in one single tomosynthesis slice. Compared to absorption tomosynthesis alone, soft tissue contrast is significantly enhanced in phase-contrast

  12. X-ray phase-contrast tomosynthesis for improved breast tissue discrimination.

    Science.gov (United States)

    Schleede, Simone; Bech, Martin; Grandl, Susanne; Sztrókay, Aniko; Herzen, Julia; Mayr, Doris; Stockmar, Marco; Potdevin, Guillaume; Zanette, Irene; Rack, Alexander; Weitkamp, Timm; Pfeiffer, Franz

    2014-03-01

    Attenuation-based tomosynthesis has proven to successfully resolve the glandular tissue overlap present in mammography. However, the ability of tomosynthesis to differentiate tumorous and glandular tissue remains limited, due to the small differences in X-ray attenuation in breast tissue. One possibility to overcome this limitation and to further increase the diagnostic value of tomosynthesis exams, is the application of recently developed grating-based phase-contrast methods, which provide complementary information on the phase shift and the local scattering power of the sample. In this study, we report on first phase-contrast breast tomosynthesis results of a mastectomy sample slice with an invasive ductal carcinoma. A slice of a mastectomy sample with histologically proven invasive ductal cancer was imaged at the synchrotron radiation source ESRF (Grenoble, France). We used a two-grating interferometer setup at the ninth fractional Talbot distance and with an X-ray energy of 23 keV. In grating interferometry absorption, differential phase, and scattering images are recorded simultaneously. The tomosynthesis scan comprises 61 projections. Multimodal tomosynthesis results were reconstructed using a standard filtered back-projection approach. Our findings are supported by a comparison of tomographic views to histopathology. Phase-contrast tomosynthesis combines the advantage of improved soft-tissue discrimination in phase-contrast imaging with the ability of tomosynthesis to provide a third dimension so that improved feature visibility is not hampered by superposition artifacts. Our results indicate superior diagnostic value due to the depth resolution supplied in tomosynthesis imaging; a region of necrotic tissue that is obscured in a projection image can clearly be depicted in one single tomosynthesis slice. Compared to absorption tomosynthesis alone, soft tissue contrast is significantly enhanced in phase-contrast tomosynthesis views, where fibrous structures

  13. Analysis of an automated background correction method for cardiovascular MR phase contrast imaging in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Rigsby, Cynthia K.; Hilpipre, Nicholas; Boylan, Emma E.; Popescu, Andrada R.; Deng, Jie [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); McNeal, Gary R. [Siemens Medical Solutions USA Inc., Customer Solutions Group, Cardiovascular MR R and D, Chicago, IL (United States); Zhang, Gang [Ann and Robert H. Lurie Children' s Hospital of Chicago Research Center, Biostatistics Research Core, Chicago, IL (United States); Choi, Grace [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Greiser, Andreas [Siemens AG Healthcare Sector, Erlangen (Germany)

    2014-03-15

    Phase contrast magnetic resonance imaging (MRI) is a powerful tool for evaluating vessel blood flow. Inherent errors in acquisition, such as phase offset, eddy currents and gradient field effects, can cause significant inaccuracies in flow parameters. These errors can be rectified with the use of background correction software. To evaluate the performance of an automated phase contrast MRI background phase correction method in children and young adults undergoing cardiac MR imaging. We conducted a retrospective review of patients undergoing routine clinical cardiac MRI including phase contrast MRI for flow quantification in the aorta (Ao) and main pulmonary artery (MPA). When phase contrast MRI of the right and left pulmonary arteries was also performed, these data were included. We excluded patients with known shunts and metallic implants causing visible MRI artifact and those with more than mild to moderate aortic or pulmonary stenosis. Phase contrast MRI of the Ao, mid MPA, proximal right pulmonary artery (RPA) and left pulmonary artery (LPA) using 2-D gradient echo Fast Low Angle SHot (FLASH) imaging was acquired during normal respiration with retrospective cardiac gating. Standard phase image reconstruction and the automatic spatially dependent background-phase-corrected reconstruction were performed on each phase contrast MRI dataset. Non-background-corrected and background-phase-corrected net flow, forward flow, regurgitant volume, regurgitant fraction, and vessel cardiac output were recorded for each vessel. We compared standard non-background-corrected and background-phase-corrected mean flow values for the Ao and MPA. The ratio of pulmonary to systemic blood flow (Qp:Qs) was calculated for the standard non-background and background-phase-corrected data and these values were compared to each other and for proximity to 1. In a subset of patients who also underwent phase contrast MRI of the MPA, RPA, and LPA a comparison was made between standard non

  14. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  15. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas.

    Science.gov (United States)

    Sabzghabaei, Anita; Shojaee, Majid; Safari, Saeed; Hatamabadi, Hamid Reza; Shirvani, Reza

    2016-01-01

    In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT) scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4), 58.5% (95% CI: 51.2-65.5), 56% (95% CI: 48.5-63.3), 79.6% (95% CI: 71.8-85.7), 1.27% (95% CI: 1.30-1.57), and 0.25% (95% CI: 0.18-0.36), respectively. The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  16. Dynamic CT in the abdominal organ, 1

    International Nuclear Information System (INIS)

    Fukuda, Kunihiko

    1980-01-01

    By utilizing a 4.5-second CT (computed tomography) scanner which allows sequential scans the changes of the iodine concentration in abdominal organs can be observed as dynamics reflected in CT number. The abdominal dynamic CT was performed as following method. After performing the preliminary scan 50ml of 60% meglumine iothalamate was rapidly injected intravenously by hands. The sequential scanning was initiated when a half dose of contrast medium was injected. In completion of the 4 sequential scans under arrested respiration the conventional post contrast scanning was performed. The analysis of 112 cases dynamically studied by CT came to the following conclusion. CT number of the abdominal aorta was greatest on the 1st or 2nd scan of the sequential scans (7.5 - 20.5 seconds after initiation of injection). Following this peak formation, CT number of the abdominal aorta declined rapidly due to both prompt diffusion of contrast medium into the extravascular space and dilution by the intravascular fluid. Iodine concentration of the abdominal aorta during the peak period was calculated as 11.3 mg/ml by the present method, being theoretically sufficient for delineation of the vessels smaller than medium size. In the patients with impaired renal function, several characteristic patterns were noted on the dynamics of contrast medium within the abdominal organs. The abdominal dynamic CT was felt to be promissing for evaluation of the renal function. (author)

  17. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  18. Pilot experimental study on continual spectrum thermal neutron in-line phase contrast radiography

    International Nuclear Information System (INIS)

    Tang Bin; Huo Heyong; Wu Yang

    2009-01-01

    The in-line phase contrast radiography is one of phase contrast imaging methods. The neutron in-line phase contrast is developed with X-rays phase contrast radiography. In the paper, the principle of in-line phase contrast is introduced briefly and the experimental result of thermal neutron in-line contrast at SPRR-300 is analysed. It shows that thermal neutron can be used as in-line phase contrast radiography and enhances the edge of some sample in radiography and complements the disadvantage of conventional neutron radiography. (authors)

  19. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  20. Diffractive generalized phase contrast for adaptive phase imaging and optical security

    DEFF Research Database (Denmark)

    Palima, Darwin; Glückstad, Jesper

    2012-01-01

    We analyze the properties of Generalized Phase Contrast (GPC) when the input phase modulation is implemented using diffractive gratings. In GPC applications for patterned illumination, the use of a dynamic diffractive optical element for encoding the GPC input phase allows for onthe- fly optimiza...... security applications and can be used to create phasebased information channels for enhanced information security....

  1. Generalised phase contrast: microscopy, manipulation and more

    DEFF Research Database (Denmark)

    Palima, Darwin; Glückstad, Jesper

    2010-01-01

    Generalised phase contrast (GPC) not only leads to more accurate phase imaging beyond thin biological samples, but serves as an enabling framework in developing tools over a wide spectrum of contemporary applications in optics and photonics, including optical trapping and micromanipulation, optic...

  2. Comparison of Global Cerebral Blood Flow Measured by Phase-Contrast Mapping MRI with O-15-H2O Positron Emission Tomography

    DEFF Research Database (Denmark)

    Vestergaard, Mark Bitsch; Lindberg, Ulrich; Aachmann-Andersen, Niels Jacob

    2017-01-01

    Purpose To compare mean global cerebral blood flow (CBF) measured by phase-contrast mapping magnetic resonance imaging (PCM MRI) and by 15O-H2O positron emission tomography (PET) in healthy subjects. PCM MRI is increasingly being used to measure mean global CBF, but has not been validated in vivo...... against an accepted reference technique. Materials and Methods Same-day measurements of CBF by 15O-H2O PET and subsequently by PCM MRI were performed on 22 healthy young male volunteers. Global CBF by PET was determined by applying a one-tissue compartment model with measurement of the arterial input...... function. Flow was measured in the internal carotid and vertebral arteries by a noncardiac triggered PCM MRI sequence at 3T. The measured flow was normalized to total brain weight determined from a volume-segmented 3D T1-weighted anatomical MR-scan. Results Mean CBF was 34.9 ± 3.4 mL/100 g/min measured...

  3. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  4. Single particle analysis based on Zernike phase contrast transmission electron microscopy.

    Science.gov (United States)

    Danev, Radostin; Nagayama, Kuniaki

    2008-02-01

    We present the first application of Zernike phase-contrast transmission electron microscopy to single-particle 3D reconstruction of a protein, using GroEL chaperonin as the test specimen. We evaluated the performance of the technique by comparing 3D models derived from Zernike phase contrast imaging, with models from conventional underfocus phase contrast imaging. The same resolution, about 12A, was achieved by both imaging methods. The reconstruction based on Zernike phase contrast data required about 30% fewer particles. The advantages and prospects of each technique are discussed.

  5. Hard X-ray phase-contrast microscope for observing transparent specimens

    Energy Technology Data Exchange (ETDEWEB)

    Kagoshima, Y.; Yokoyama, Y.; Niimi, T.; Koyama, T.; Tsusaka, Y.; Matsui, J. [Himeji Institute of Technology, Graduate School of Science, Hyogo (Japan); Takai, K. [Japan synchrotron Radiation Research Institute, Mikazuki, Hyogo (Japan)

    2002-08-01

    A hard X-ray transmission imaging microscope has been in use at the beamline BL24XU of Spring-8. It makes use of a phase zone plate made of tantalum as its X-ray lens, and is capable of imaging the structure as fine as 125-nm line-and-space pattern. The Zernike's phase-contrast method has been implemented to the microscope with phase plates made of gold. The photon energy was tuned to 12 keV just above the L{sub 3} absorption edge of gold (11.9 keV) in order to increase the image contrast. Polystyrene micro particles as transparent specimens were imaged clearly in the opposite image contrast with phase plates to shift the phase of the central order spectra in the back focal plane of the objective by one-quarter and three-quarters of a period, while the absorption contrast image showed little image contrast. Performance of the newly developed phase zone plate has been tested and it was confirmed that the structure as fine as 60-mm line-and-space pattern was able to be imaged. (authors)

  6. Rapid non-contrast magnetic resonance imaging for post appendectomy intra-abdominal abscess in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Megan H. [Washington University School of Medicine in St. Louis, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Eutsler, Eric P.; Khanna, Geetika [Washington University School of Medicine in St. Louis, Pediatric Radiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Sheybani, Elizabeth F. [Mercy Hospital St. Louis, Department of Radiology, St. Louis, MO (United States)

    2017-07-15

    Acute appendicitis, especially if perforated at presentation, is often complicated by postoperative abscess formation. The detection of a postoperative abscess relies primarily on imaging. This has traditionally been done with contrast-enhanced computed tomography. Non-contrast magnetic resonance imaging (MRI) has the potential to accurately detect intra-abdominal abscesses, especially with the use of diffusion-weighted imaging (DWI). To evaluate our single-center experience with a rapid non-contrast MRI protocol evaluating post-appendectomy abscesses in children with persistent postsurgical symptoms. In this retrospective, institutional review board-approved study, all patients underwent a clinically indicated non-contrast 1.5- or 3-Tesla abdomen/pelvis MRI consisting of single-shot fast spin echo, inversion recovery and DWI sequences. All MRI studies were reviewed by two blinded pediatric radiologists to identify the presence of a drainable fluid collection. Each fluid collection was further characterized as accessible or not accessible for percutaneous or transrectal drainage. Imaging findings were compared to clinical outcome. Seven of the 15 patients had a clinically significant fluid collection, and 5 of these patients were treated with percutaneous drain placement or exploratory laparotomy. The other patients had a phlegmon or a clinically insignificant fluid collection and were discharged home within 48 h. Rapid non-contrast MRI utilizing fluid-sensitive and DWI sequences can be used to identify drainable fluid collections in post-appendectomy patients. This protocol can be used to triage patients between conservative management vs. abscess drainage without oral/intravenous contrast or exposure to ionizing radiation. (orig.)

  7. Rapid non-contrast magnetic resonance imaging for post appendectomy intra-abdominal abscess in children

    International Nuclear Information System (INIS)

    Lee, Megan H.; Eutsler, Eric P.; Khanna, Geetika; Sheybani, Elizabeth F.

    2017-01-01

    Acute appendicitis, especially if perforated at presentation, is often complicated by postoperative abscess formation. The detection of a postoperative abscess relies primarily on imaging. This has traditionally been done with contrast-enhanced computed tomography. Non-contrast magnetic resonance imaging (MRI) has the potential to accurately detect intra-abdominal abscesses, especially with the use of diffusion-weighted imaging (DWI). To evaluate our single-center experience with a rapid non-contrast MRI protocol evaluating post-appendectomy abscesses in children with persistent postsurgical symptoms. In this retrospective, institutional review board-approved study, all patients underwent a clinically indicated non-contrast 1.5- or 3-Tesla abdomen/pelvis MRI consisting of single-shot fast spin echo, inversion recovery and DWI sequences. All MRI studies were reviewed by two blinded pediatric radiologists to identify the presence of a drainable fluid collection. Each fluid collection was further characterized as accessible or not accessible for percutaneous or transrectal drainage. Imaging findings were compared to clinical outcome. Seven of the 15 patients had a clinically significant fluid collection, and 5 of these patients were treated with percutaneous drain placement or exploratory laparotomy. The other patients had a phlegmon or a clinically insignificant fluid collection and were discharged home within 48 h. Rapid non-contrast MRI utilizing fluid-sensitive and DWI sequences can be used to identify drainable fluid collections in post-appendectomy patients. This protocol can be used to triage patients between conservative management vs. abscess drainage without oral/intravenous contrast or exposure to ionizing radiation. (orig.)

  8. A method to implement the reservoir-wave hypothesis using phase-contrast magnetic resonance imaging

    OpenAIRE

    Gray, Robert D.M.; Parker, Kim H.; Quail, Michael A.; Taylor, Andrew M.; Biglino, Giovanni

    2016-01-01

    The reservoir-wave hypothesis states that the blood pressure waveform can be usefully divided into a “reservoir pressure” related to the global compliance and resistance of the arterial system, and an “excess pressure” that depends on local conditions. The formulation of the reservoir-wave hypothesis applied to the area waveform is shown, and the analysis is applied to area and velocity data from high-resolution phase-contrast cardiovascular magnetic resonance (CMR) imaging. A validation stud...

  9. Grating-based X-ray phase contrast for biomedical imaging applications

    International Nuclear Information System (INIS)

    Pfeiffer, Franz; Willner, Marian; Chabior, Michael; Herzen, Julia; Helmholtz-Zentrum Geesthacht, Geesthacht; Auweter, Sigrid; Reiser, Maximilian; Bamberg, Fabian

    2013-01-01

    In this review article we describe the development of grating-based X-ray phase-contrast imaging, with particular emphasis on potential biomedical applications of the technology. We review the basics of image formation in grating-based phase-contrast and dark-field radiography and present some exemplary multimodal radiography results obtained with laboratory X-ray sources. Furthermore, we discuss the theoretical concepts to extend grating-based multimodal radiography to quantitative transmission, phase-contrast, and dark-field scattering computed tomography. (orig.)

  10. In-line phase contrast micro-CT reconstruction for biomedical specimens.

    Science.gov (United States)

    Fu, Jian; Tan, Renbo

    2014-01-01

    X-ray phase contrast micro computed tomography (micro-CT) can non-destructively provide the internal structure information of soft tissues and low atomic number materials. It has become an invaluable analysis tool for biomedical specimens. Here an in-line phase contrast micro-CT reconstruction technique is reported, which consists of a projection extraction method and the conventional filter back-projection (FBP) reconstruction algorithm. The projection extraction is implemented by applying the Fourier transform to the forward projections of in-line phase contrast micro-CT. This work comprises a numerical study of the method and its experimental verification using a biomedical specimen dataset measured at an X-ray tube source micro-CT setup. The numerical and experimental results demonstrate that the presented technique can improve the imaging contrast of biomedical specimens. It will be of interest for a wide range of in-line phase contrast micro-CT applications in medicine and biology.

  11. Utility of intravenous nonionic contrast media for abdominal CT in patients with renal dysfunction

    International Nuclear Information System (INIS)

    Craig, B.M.; Alpern, M.B.; Sandler, M.A.; Pearlberg, J.L.; Swanson, D.P.

    1987-01-01

    The safety and efficacy of a nonionic contrast medium (NICM) for CT enhancements in patients with renal dysfunction were evaluated. Thirty consecutive patients referred for abdominal CT with a serum creatinine (SCr) level over 5 mg/dL or a SCr level of 2-5 mg/dL and another risk factor (e.g., diabetes, single kidney) received NICM. Each was matched with a control who received the same 150-mL bolus of a conventional medium. No adverse reactions or significant alterations in SCr values were found in the NICM patients. No significant differences between the patient groups were found in blinded subjective image quality ratings or measured attenuation values of a parenchymal organs and vascular structures (with the exception of less renal enhancement in the NICM patients, reflecting their renal dysfunction). Use of an NICM is a safe and effective method for contrast medium-enhanced CT in patients with renal dysfunction

  12. Measurement of blood flow in the left ventricle and aorta using clinical 2D cine phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nakamura, Masanori; Wada, Shigeo; Yokosawa, Suguru; Yamaguchi, Takami; Isoda, Haruo; Takeda, Hiroyasu

    2007-01-01

    A recent development in phase-contrast magnetic resonance imaging (cine PC-MRI) allows the detailed measurement of the blood flow in humans. The objectives of this study are twofold: to discuss the utility of clinical two-dimensional (2D) cine PC-MRI as a practical tool for analyzing hemodynamics in the aorta and left ventricle; to provide flow information at those places as references for computational fluid dynamics studies. Using 2D cine PC-MRI, we mapped velocity profiles at various cross sections of the aorta and left ventricle. The results illustrated the main flow events in the left ventricle during the cardiac cycle, such as ventricular ejection and suction, while the secondary flows were less clear. The velocity profile at the entrance of the ascending aorta appeared to be slightly skewed posteriorly in early systole, but the flow in the central zone of the section was rapid. The estimated stroke volume, peak Reynolds numbers, and Womersley numbers were within the normal physiological range. A sequence of secondary flow images from the plane of the aortic valve to the descending aorta revealed the evolution of a helical flow within the aorta. Flows entering the aortic branches were captured well. Those results demonstrate that clinical 2D cine PC-MRI is a practical adjunct for analyzing blood flow in vivo and would be useful as references to check validity of flow dynamics obtained by computer simulations. (author)

  13. Acute iatrogenic polycythemia induced by massive red blood cell transfusion during subtotal abdominal colectomy

    Directory of Open Access Journals (Sweden)

    David Chiapaikeo

    2015-03-01

    Full Text Available A 46 year old man was transfused ten units of packed red blood cells during subtotal colectomy after intraoperative point-of-care testing values demonstrated hemoglobin values less than seven grams per deciliter (g/dL. A post-operative hemoglobin analyzed in a standard hematologic laboratory revealed a hemoglobin value of 27.8 g/dL. He underwent emergent red blood cell depletion therapy which decreased his hemoglobin to 7.5 g/dL. The physiologic consequences of iatrogenic polycythemia caused by massive transfusion during major abdominal surgery must take into account the fluid shifts that interplay between the osmotic load, viscosity of blood, and postoperative third spacing of fluid. Treatment of acute iatrogenic polycythemia can be effectively accomplished by red blood cell depletion therapy. However, fluid shifts caused by massive transfusion followed by rapid red cell depletion produce a unique physiologic state that is without a well-described algorithm for management.

  14. X-ray differential phase-contrast tomographic reconstruction with a phase line integral retrieval filter

    International Nuclear Information System (INIS)

    Fu, Jian; Hu, Xinhua; Li, Chen

    2015-01-01

    We report an alternative reconstruction technique for x-ray differential phase-contrast computed tomography (DPC-CT). This approach is based on a new phase line integral projection retrieval filter, which is rooted in the derivative property of the Fourier transform and counteracts the differential nature of the DPC-CT projections. It first retrieves the phase line integral from the DPC-CT projections. Then the standard filtered back-projection (FBP) algorithms popular in x-ray absorption-contrast CT are directly applied to the retrieved phase line integrals to reconstruct the DPC-CT images. Compared with the conventional DPC-CT reconstruction algorithms, the proposed method removes the Hilbert imaginary filter and allows for the direct use of absorption-contrast FBP algorithms. Consequently, FBP-oriented image processing techniques and reconstruction acceleration softwares that have already been successfully used in absorption-contrast CT can be directly adopted to improve the DPC-CT image quality and speed up the reconstruction

  15. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  16. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  17. Estimation of pulmonary vascular resistance in patients with pulmonary fibrosis by phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ayukawa, Yuichiro; Murayama, Sadayuki; Tsuchiya, Nanae; Yara, Satomi; Fujita, Jiro

    2011-01-01

    The aim of this study was to assess pulmonary vascular resistance (PVR) in patients with pulmonary fibrosis (PF) by phase-contrast magnetic resonance imaging (MRI). Subjects were 11 healthy volunteers and 11 patients with PF. Using phase-contrast MRI, we measured pulmonary arterial blood flow and calculated the parameters of PVR. Parameters were compared between volunteers and patients using unpaired t-tests. The diagnostic capability of the parameters was evaluated by receiver operating characteristic (ROC) curve analysis. Patients underwent respiratory function tests (RFTs) and chest computed tomography (CT), and they were correlated with MRI parameters. Most MRI parameters were significantly different between volunteers and patients (t-test P values were <0.05 in 9 of 10 parameters). Regarding the RFT and CT visual score, only the %DLco/VA and acceleration time and the CT visual score and average flow volume had significant correlation [r=-0.667 (P=0.024) and r=-0.6 (P=0.031)], respectively. Our findings suggest that PVR derived from phase-contrast MRI is significantly higher in patients with PF than in volunteers. However, all but two of these parameters may not correlate with the severity of PF. (author)

  18. Automated extraction of metastatic liver cancer regions from abdominal contrast CT images

    International Nuclear Information System (INIS)

    Yamakawa, Junki; Matsubara, Hiroaki; Kimura, Shouta; Hasegawa, Junichi; Shinozaki, Kenji; Nawano, Shigeru

    2010-01-01

    In this paper, automated extraction of metastatic liver cancer regions from abdominal contrast X-ray CT images is investigated. Because even in Japan, cases of metastatic liver cancers are increased due to recent Europeanization and/or Americanization of Japanese eating habits, development of a system for computer aided diagnosis of them is strongly expected. Our automated extraction procedure consists of following four steps; liver region extraction, density transformation for enhancement of cancer regions, segmentation for obtaining candidate cancer regions, and reduction of false positives by shape feature. Parameter values used in each step of the procedure are decided based on density and shape features of typical metastatic liver cancers. In experiments using practical 20 cases of metastatic liver tumors, it is shown that 56% of true cancers can be detected successfully from CT images by the proposed procedure. (author)

  19. X-ray phase-contrast CT of a pancreatic ductal adenocarcinoma mouse model.

    Directory of Open Access Journals (Sweden)

    Arne Tapfer

    Full Text Available To explore the potential of grating-based x-ray phase-contrast computed tomography (CT for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i high-resolution synchrotron radiation (SR imaging and ii dose-reduced imaging using either synchrotron radiation or a conventional x-ray tube source. These experimental settings were chosen to assess the potential of phase-contrast imaging for two different types of application: i high-performance imaging for virtual microscopy applications and ii biomedical imaging with increased soft-tissue contrast for in-vivo applications. For validation and as a reference, histological slicing and magnetic resonance imaging (MRI were performed on the same mouse specimen. For each x-ray imaging setup, attenuation and phase-contrast images were compared visually with regard to contrast in general, and specifically concerning the recognizability of lesions and cancerous tissue. To quantitatively assess contrast, the contrast-to-noise ratios (CNR of selected regions of interest (ROI in the attenuation images and the phase images were analyzed and compared. It was found that both for virtual microscopy and for in-vivo applications, there is great potential for phase-contrast imaging: in the SR-based benchmarking data, fine details about tissue composition are accessible in the phase images and the visibility of solid tumor tissue under dose-reduced conditions is markedly superior in the phase images. The present study hence demonstrates improved diagnostic value with phase-contrast CT in a mouse model of a complex endogenous cancer, promoting the use and further development of grating-based phase-contrast CT for biomedical imaging applications.

  20. Phase contrast image segmentation using a Laue analyser crystal

    International Nuclear Information System (INIS)

    Kitchen, Marcus J; Paganin, David M; Lewis, Robert A; Pavlov, Konstantin M; Uesugi, Kentaro; Allison, Beth J; Hooper, Stuart B

    2011-01-01

    Dual-energy x-ray imaging is a powerful tool enabling two-component samples to be separated into their constituent objects from two-dimensional images. Phase contrast x-ray imaging can render the boundaries between media of differing refractive indices visible, despite them having similar attenuation properties; this is important for imaging biological soft tissues. We have used a Laue analyser crystal and a monochromatic x-ray source to combine the benefits of both techniques. The Laue analyser creates two distinct phase contrast images that can be simultaneously acquired on a high-resolution detector. These images can be combined to separate the effects of x-ray phase, absorption and scattering and, using the known complex refractive indices of the sample, to quantitatively segment its component materials. We have successfully validated this phase contrast image segmentation (PCIS) using a two-component phantom, containing an iodinated contrast agent, and have also separated the lungs and ribcage in images of a mouse thorax. Simultaneous image acquisition has enabled us to perform functional segmentation of the mouse thorax throughout the respiratory cycle during mechanical ventilation.

  1. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  2. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  3. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  4. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas

    Directory of Open Access Journals (Sweden)

    Anita Sabzghabaei

    2016-01-01

    Full Text Available Introduction: In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Methods: Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. Results: 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4, 58.5% (95% CI: 51.2-65.5, 56% (95% CI: 48.5-63.3, 79.6% (95% CI: 71.8-85.7, 1.27% (95% CI: 1.30-1.57, and 0.25% (95% CI: 0.18-0.36, respectively. Conclusion: The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  5. Value of Single-Dose Contrast-Enhanced Magnetic Resonance Angiography Versus Intraarterial Digital Subtraction Angiography in Therapy Indications in Abdominal and Iliac Arteries

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Schaefer, Fritz K. W.; Mueller-Huelsbeck, Stefan; Both, Markus; Heller, Martin; Jahnke, Thomas

    2007-01-01

    The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committee was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weight in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30 o , field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses ≥50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies

  6. Practical aspects of Boersch phase contrast electron microscopy of biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Andreas [Max-Planck-Institute of Biophysics, Department of Structural Biology, Max-von-Laue-Str. 3, D-60439 Frankfurt (Germany); Muzik, Heiko; Vieker, Henning; Turchanin, Andrey; Beyer, Andre; Goelzhaeuser, Armin [University of Bielefeld, Physics of Supramolecular Systems and Surfaces, Universitaetsstr. 25, D-33615 Bielefeld (Germany); Lacher, Manfred; Steltenkamp, Siegfried; Schmitz, Sam; Holik, Peter [Caesar Research Center, Ludwig-Erhard-Allee 2, D-53175 Bonn (Germany); Kuehlbrandt, Werner [Max-Planck-Institute of Biophysics, Department of Structural Biology, Max-von-Laue-Str. 3, D-60439 Frankfurt (Germany); Rhinow, Daniel, E-mail: daniel.rhinow@biophys.mpg.de [Max-Planck-Institute of Biophysics, Department of Structural Biology, Max-von-Laue-Str. 3, D-60439 Frankfurt (Germany)

    2012-05-15

    Implementation of physical phase plates into transmission electron microscopes to achieve in-focus contrast for ice-embedded biological specimens poses several technological challenges. During the last decade several phase plates designs have been introduced and tested for electron cryo-microscopy (cryoEM), including thin film (Zernike) phase plates and electrostatic devices. Boersch phase plates (BPPs) are electrostatic einzel lenses shifting the phase of the unscattered beam by an arbitrary angle. Adjusting the phase shift to 90 Degree-Sign achieves the maximum contrast transfer for phase objects such as biomolecules. Recently, we reported the implementation of a BPP into a dedicated phase contrast aberration-corrected electron microscope (PACEM) and demonstrated its use to generate in-focus contrast of frozen-hydrated specimens. However, a number of obstacles need to be overcome before BPPs can be used routinely, mostly related to the phase plate devices themselves. CryoEM with a physical phase plate is affected by electrostatic charging, obliteration of low spatial frequencies, and mechanical drift. Furthermore, BPPs introduce single sideband contrast (SSB), due to the obstruction of Friedel mates in the diffraction pattern. In this study we address the technical obstacles in detail and show how they may be overcome. We use X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) to identify contaminants responsible for electrostatic charging, which occurs with most phase plates. We demonstrate that obstruction of low-resolution features is significantly reduced by lowering the acceleration voltage of the microscope. Finally, we present computational approaches to correct BPP images for SSB contrast and to compensate for mechanical drift of the BPP. -- Highlights: Black-Right-Pointing-Pointer Various obstacles need to be overcome before Boersch phase plates can be used routinely. Black-Right-Pointing-Pointer Technical problems include

  7. Practical aspects of Boersch phase contrast electron microscopy of biological specimens

    International Nuclear Information System (INIS)

    Walter, Andreas; Muzik, Heiko; Vieker, Henning; Turchanin, Andrey; Beyer, André; Gölzhäuser, Armin; Lacher, Manfred; Steltenkamp, Siegfried; Schmitz, Sam; Holik, Peter; Kühlbrandt, Werner; Rhinow, Daniel

    2012-01-01

    Implementation of physical phase plates into transmission electron microscopes to achieve in-focus contrast for ice-embedded biological specimens poses several technological challenges. During the last decade several phase plates designs have been introduced and tested for electron cryo-microscopy (cryoEM), including thin film (Zernike) phase plates and electrostatic devices. Boersch phase plates (BPPs) are electrostatic einzel lenses shifting the phase of the unscattered beam by an arbitrary angle. Adjusting the phase shift to 90° achieves the maximum contrast transfer for phase objects such as biomolecules. Recently, we reported the implementation of a BPP into a dedicated phase contrast aberration-corrected electron microscope (PACEM) and demonstrated its use to generate in-focus contrast of frozen–hydrated specimens. However, a number of obstacles need to be overcome before BPPs can be used routinely, mostly related to the phase plate devices themselves. CryoEM with a physical phase plate is affected by electrostatic charging, obliteration of low spatial frequencies, and mechanical drift. Furthermore, BPPs introduce single sideband contrast (SSB), due to the obstruction of Friedel mates in the diffraction pattern. In this study we address the technical obstacles in detail and show how they may be overcome. We use X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) to identify contaminants responsible for electrostatic charging, which occurs with most phase plates. We demonstrate that obstruction of low-resolution features is significantly reduced by lowering the acceleration voltage of the microscope. Finally, we present computational approaches to correct BPP images for SSB contrast and to compensate for mechanical drift of the BPP. -- Highlights: ► Various obstacles need to be overcome before Boersch phase plates can be used routinely. ► Technical problems include electrostatic charging, mechanical drift, and image artefacts.

  8. Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison

    International Nuclear Information System (INIS)

    Yan, Aimin; Wu, Xizeng; Liu, Hong

    2011-01-01

    Purpose: The robustness of the phase retrieval methods is of critical importance for limiting and reducing radiation doses involved in x-ray phase contrast imaging. This work is to compare the robustness of two phase retrieval methods by analyzing the phase maps retrieved from the experimental images of a phantom. Methods: Two phase retrieval methods were compared. One method is based on the transport of intensity equation (TIE) for phase contrast projections, and the TIE-based method is the most commonly used method for phase retrieval in the literature. The other is the recently developed attenuation-partition based (AP-based) phase retrieval method. The authors applied these two methods to experimental projection images of an air-bubble wrap phantom for retrieving the phase map of the bubble wrap. The retrieved phase maps obtained by using the two methods are compared. Results: In the wrap's phase map retrieved by using the TIE-based method, no bubble is recognizable, hence, this method failed completely for phase retrieval from these bubble wrap images. Even with the help of the Tikhonov regularization, the bubbles are still hardly visible and buried in the cluttered background in the retrieved phase map. The retrieved phase values with this method are grossly erroneous. In contrast, in the wrap's phase map retrieved by using the AP-based method, the bubbles are clearly recovered. The retrieved phase values with the AP-based method are reasonably close to the estimate based on the thickness-based measurement. The authors traced these stark performance differences of the two methods to their different techniques employed to deal with the singularity problem involved in the phase retrievals. Conclusions: This comparison shows that the conventional TIE-based phase retrieval method, regardless if Tikhonov regularization is used or not, is unstable against the noise in the wrap's projection images, while the AP-based phase retrieval method is shown in these

  9. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  10. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  11. Quantitative phase imaging and differential interference contrast imaging for biological TEM

    International Nuclear Information System (INIS)

    Allman, B.E.; McMahon, P.J.; Barone-Nugent, E.D.; Nugent, E.D.

    2002-01-01

    Full text: Phase microscopy is a central technique in science. An experienced microscopist uses this effect to visualise (edge) structure within transparent samples by slightly defocusing the microscope. Although widespread in optical microscopy, phase contrast transmission electron microscopy (TEM) has not been widely adopted. TEM for biological specimens has largely relied on staining techniques to yield sufficient contrast. We show here a simple method for quantitative TEM phase microscopy that quantifies this phase contrast effect. Starting with conventional, digital, bright field images of the sample, our algorithm provides quantitative phase information independent of the sample's bright field intensity image. We present TEM phase images of a range of stained and unstained, biological and material science specimens. This independent phase and intensity information is then used to emulate a range of phase visualisation images familiar to optical microscopy, e.g. differential interference contrast. The phase images contain features not visible with the other imaging modalities. Further, if the TEM samples have been prepared on a microtome to a uniform thickness, the phase information can be converted into refractive index structure of the specimen. Copyright (2002) Australian Society for Electron Microscopy Inc

  12. Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty.

    Science.gov (United States)

    Chen, Guoqiang; Zheng, Jiaping; Xiao, Qing; Liu, Yunsheng

    2013-06-01

    The aim of this study was to evaluate the application of phase-contrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty (EA) for patients with obstructive hydrocephalus. The clinical diagnosis of hydrocephalus caused by aqueduct obstruction in 23 patients was confirmed by phase-contrast cine MRI examination. The patients were treated with EA and MRI was repeated during the follow-up. The cerebrospinal fluid (CSF) flow velocity in the aqueduct was measured to determine whether the aqueduct was obstructed. The results of phase-contrast cine MRI examinations indicated that there was no CSF flow in the aqueduct for all patients prior to surgery. Aqueductoplasty was successfully performed in all patients. The results of phase-contrast cine MRI examinations performed a week after surgery demonstrated an average CSF flow velocity of 4.74±1.77 cm/sec. During the follow-up, intracranial hypertension recurred in two patients in whom CSF flow was not observed in the aqueduct by the phase-contrast cine MRI scan. Aqueduct re-occlusion was revealed by an endoscopic exploration. By measuring the CSF flow velocity, phase-contrast cine MRI accurately identifies aqueduct obstruction. Cine MRI is a nontraumatic, simple and reliable method for determining whether the aqueduct is successfully opened following aqueductoplasty.

  13. Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hao; Ercius, Peter [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Nellist, Peter D. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Ophus, Colin, E-mail: clophus@lbl.gov [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2016-12-15

    The ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. In this work we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials. - Highlights: • This work demonstrates a phase contrast imaging method by combining a pre-specimen phase plate with ptychogrpahy. • This method is shown to have a high phase contrast transfer efficiency at both low and high spatial frequencies. • Unlike CTEM which uses a heavy defocus to gain contrast, the phase plate gives a linear phase contrast at zero defocus aberrations. • Image simulations of DNA suggest this method is highly attractive for imaging beam sensitive materials at a low dose.

  14. A case of pulmonary edema developed after intraarterial injection of iodinated contrast medium

    International Nuclear Information System (INIS)

    Min, Byoung Chol; Chun, Kang Woo; Koh, Jae Hyu; Yoon, Jong Sup

    1982-01-01

    Pulmonary edema is a rare adverse reaction to the iodinated contrast medium. Complaining of huge abdominal mass, a 52 years old female was admitted to the Hangang Sungsim Hospital. On physical examination, the patient appeared to be healthy. She had stable vital signs, i.e. BP: 120/80 mmHg, pulse rate: 80/min.etc. An adult head sized mass was palpated in the left mid and lower abdomen. Otherwise nonspecific. On laboratory studies the positive findings were 8-10 WBC/HPF in urine, 25.6 mg/dl for BUN and PVC in EKG. It was negative for urine protein, serum creatinline and liver function test. We injected 100 ml and 30 ml of Urografin 60 through the abdominal aorta dividing 3 times and major branches of the abdominal aorta, respectively. Immediately after complicating angiography, interstitial pulmonary edema was found, showing blurring of the vascular margins, perivascular haziness and thickening of the interlobular septal lines in the both lower lung fields. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We have experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechanisms of pulmonary edema caused by intravascular injection of the iodinated contrast materials

  15. Grating-based x-ray differential phase contrast imaging with twin peaks in phase-stepping curves—phase retrieval and dewrapping

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yi; Xie, Huiqiao; Tang, Xiangyang, E-mail: xiangyang.tang@emory.edu [Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, Georgia 30322 (United States); Cai, Weixing [Department of Radiation Oncology, Brigham and Women’s Hospital Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115 (United States); Mao, Hui [Laboratory of Functional and Molecular Imaging and Nanomedicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road NE, Atlanta, Georgia 30329 (United States)

    2016-06-15

    Purpose: X-ray differential phase contrast CT implemented with Talbot interferometry employs phase-stepping to extract information of x-ray attenuation, phase shift, and small-angle scattering. Since inaccuracy may exist in the absorption grating G{sub 2} due to an imperfect fabrication, the effective period of G{sub 2} can be as large as twice the nominal period, leading to a phenomenon of twin peaks that differ remarkably in their heights. In this work, the authors investigate how to retrieve and dewrap the phase signal from the phase-stepping curve (PSC) with the feature of twin peaks for x-ray phase contrast imaging. Methods: Based on the paraxial Fresnel–Kirchhoff theory, the analytical formulae to characterize the phenomenon of twin peaks in the PSC are derived. Then an approach to dewrap the retrieved phase signal by jointly using the phases of the first- and second-order Fourier components is proposed. Through an experimental investigation using a prototype x-ray phase contrast imaging system implemented with Talbot interferometry, the authors evaluate and verify the derived analytic formulae and the proposed approach for phase retrieval and dewrapping. Results: According to theoretical analysis, the twin-peak phenomenon in PSC is a consequence of combined effects, including the inaccuracy in absorption grating G{sub 2}, mismatch between phase grating and x-ray source spectrum, and finite size of x-ray tube’s focal spot. The proposed approach is experimentally evaluated by scanning a phantom consisting of organic materials and a lab mouse. The preliminary data show that compared to scanning G{sub 2} over only one single nominal period and correcting the measured phase signal with an intuitive phase dewrapping method that is being used in the field, stepping G{sub 2} over twice its nominal period and dewrapping the measured phase signal with the proposed approach can significantly improve the quality of x-ray differential phase contrast imaging in both

  16. Intra-abdominal tuberculous peritonitis

    International Nuclear Information System (INIS)

    Schneider, G.; Ahlhelm, F.; Altmeyer, K.; Kramann, B.; Hennes, P.; Pueschel, W.; Karadiakos, N.

    2001-01-01

    We report the case of a 15-year-old boy suffering from progressive dyspnea on exertion and painful abdominal protrusion. Final diagnosis of intra-abdominal tuberculosis (TB), including lymphadenopathy and abdominal abscess formation, was made following elective laparotomy. This type of disease is a rare manifestation of extrapulmonary tuberculosis. The imaging findings in unenhanced and contrast-enhanced MRI and laparoscopic images are presented. Differential diagnosis of abdominal abscess formation and other fungal or bacteriological infections, as well as the imaging findings of this type of lesion, are discussed. This case demonstrates that atypical manifestation of TB may remain unrecognized; thus, awareness of this kind of manifestation of tuberculosis may prevent patients from being subjected to inappropriate therapies. (orig.)

  17. Intra-abdominal tuberculous peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, G.; Ahlhelm, F.; Altmeyer, K.; Kramann, B. [Dept. of Diagnostic Radiology, University Hospital, Homburg (Germany); Hennes, P. [Dept. of Pediatrics, University Hospital, Homburg (Germany); Pueschel, W. [Dept. of Pathology, University Hospital, Homburg (Germany); Karadiakos, N. [Dept. of Pediatric Surgery, University Hospital, Homburg (Germany)

    2001-07-01

    We report the case of a 15-year-old boy suffering from progressive dyspnea on exertion and painful abdominal protrusion. Final diagnosis of intra-abdominal tuberculosis (TB), including lymphadenopathy and abdominal abscess formation, was made following elective laparotomy. This type of disease is a rare manifestation of extrapulmonary tuberculosis. The imaging findings in unenhanced and contrast-enhanced MRI and laparoscopic images are presented. Differential diagnosis of abdominal abscess formation and other fungal or bacteriological infections, as well as the imaging findings of this type of lesion, are discussed. This case demonstrates that atypical manifestation of TB may remain unrecognized; thus, awareness of this kind of manifestation of tuberculosis may prevent patients from being subjected to inappropriate therapies. (orig.)

  18. Blood Pool Contrast-enhanced Magnetic Resonance Angiography with Correlation to Digital Subtraction Angiography: A Pictorial Review

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Magnetic resonance angiography (MRA provides noninvasive visualization of the vascular supply of soft tissue masses and vascular pathology, without harmful radiation. This is important for planning an endovascular intervention, and helps to evaluate the efficiency and effectiveness of the treatment. MRA with conventional extracellular contrast agents relies on accurate contrast bolus timing, limiting the imaging window to first-pass arterial phase. The recently introduced blood pool contrast agent (BPCA, gadofosveset trisodium, reversibly binds to human serum albumin, resulting in increased T1 relaxivity and prolonged intravascular retention time, permitting both first-pass and steady-state phase high-resolution imaging. In our practice, high-quality MRA serves as a detailed "roadmap" for the needed endovascular intervention. Cases of aortoiliac occlusive disease, inferior vena cava thrombus, pelvic congestion syndrome, and lower extremity arteriovenous malformation are discussed in this article. MRA was acquired at 1.5 T with an 8-channel phased array coil after intravenous administration of gadofosveset (0.03 mmol/kg body weight, at the first-pass phase. In the steady-state, serial T1-weighted 3D spoiled gradient echo images were obtained with high resolution. All patients underwent digital subtraction angiography (DSA and endovascular treatment. MRA and DSA findings of vascular anatomy and pathology are discussed and correlated. BPCA-enhanced MRA provides high-quality first-pass and steady-state vascular imaging. This could increase the diagnostic accuracy and create a detailed map for pre-intervention planning. Understanding the pharmacokinetics of BPCA and being familiar with the indications and technique of MRA are important for diagnosis and endovascular intervention.

  19. Therapeutical effect on blood-flow in three-phase scanning in primary malignant tumours and acute osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Kovacic, K; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine; Cepulic, M [Children` s Hospital, Zagreb (Croatia)

    1994-10-01

    In the studies where the bone scan was limited only to the late static image, the main disadvantage was its nonspecifity. With three-phase bone scan the number of false positive findings was reduced by some peculiar diseases; for instance, acute hematogenous osteomyelitis. It is well known that various diseases, such as nonunion of the fracture, some surgical interventions, avascular necrosis... can imitate acute osteomyelitis on the static image. These diseases can only be differentiated from inflammation by blood-flow. Therefore, in all patients with the diagnosis of primary bone disease tumor, inflammation, trauma, aseptic necrosis... three-phase bone scintigraphy is performed. Here, only the patients with acute osteomyelitis and primary malignant bone tumors will be presented: the basic scintigram was done before the therapy started, and the second one as a part of the follow-up - in some patients during the therapy and in some after its ending. We noticed that the most reliable part of three-phase bone scan responding to the therapy is angioscintigraphy (blood-flow) and in some cases early static (blood-pool) image. These two phases, especially the first one, are in good correlation with the clinic, in contrast to the third phase which is delayed. From the presented cases it could be concluded that in acute osteomyelitis and primary malignant tumors, blood-flow and blood-pool images are unavoidable phases of the bone scanning when we want to correctly evaluate the effects of the therapy. (author).

  20. Measurement of cerebral blood flow with two-dimensional cine phase-contrast MR imaging. Evaluation of normal subjects and patients with vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Osada, Hisato [Saitama Medical School, Kawagoe (Japan). Saitama Medical Center

    1995-03-01

    The purpose of this study was to determine whether or not the vertebral flow of patients with vertigo and normal brain magnetic resonance (MR) images was decreased in comparison with normal controls. Cerebral blood flow (CBF) was quantitatively measured by a two-dimensional phase contrast cine MR imaging technique in 24 normal controls (mean age, 38.6 years; range, 12-70) and 23 patients (mean age, 53.7 years; range, 19-76) with a 1.5 Tesla MR imaging unit. Inter-and intraobserver variation in blood flow measurements was small (r=0.970, standard error of the estimate [SEE]=2.9 ml, n=80; r=0.963, SEE=4.6 ml, n=40, respectively), In the normal group, mean summed vertebral flow (171 ml/min, SD=40.6) was significantly less than mean summed carotid flow (523 ml/min, SD=111). Right vertebral flow (80.2 ml/min, SD=30.5) was less than left vertebral flow (91.2 ml/min, SD=38.2), but the difference was not statistically significant (p<0.05), In the 23 patients, although the summed vertebral flows of two patients (63.3, 88.8 ml/min) were significantly less than that of the normal group, mean summed vertebral flow (165 ml/min, SD=59.1) showed no significant difference from that of the normal group (p<0.05). In this study, the majority of patients had normal CBF. This method is clinically useful for estimating CBF. (author).

  1. Measurement of cerebral blood flow with two-dimensional cine phase-contrast MR imaging. Evaluation of normal subjects and patients with vertigo

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Osada, Hisato

    1995-01-01

    The purpose of this study was to determine whether or not the vertebral flow of patients with vertigo and normal brain magnetic resonance (MR) images was decreased in comparison with normal controls. Cerebral blood flow (CBF) was quantitatively measured by a two-dimensional phase contrast cine MR imaging technique in 24 normal controls (mean age, 38.6 years; range, 12-70) and 23 patients (mean age, 53.7 years; range, 19-76) with a 1.5 Tesla MR imaging unit. Inter-and intraobserver variation in blood flow measurements was small (r=0.970, standard error of the estimate [SEE]=2.9 ml, n=80; r=0.963, SEE=4.6 ml, n=40, respectively), In the normal group, mean summed vertebral flow (171 ml/min, SD=40.6) was significantly less than mean summed carotid flow (523 ml/min, SD=111). Right vertebral flow (80.2 ml/min, SD=30.5) was less than left vertebral flow (91.2 ml/min, SD=38.2), but the difference was not statistically significant (p<0.05), In the 23 patients, although the summed vertebral flows of two patients (63.3, 88.8 ml/min) were significantly less than that of the normal group, mean summed vertebral flow (165 ml/min, SD=59.1) showed no significant difference from that of the normal group (p<0.05). In this study, the majority of patients had normal CBF. This method is clinically useful for estimating CBF. (author)

  2. Origins of phase contrast in the atomic force microscope in liquids.

    Science.gov (United States)

    Melcher, John; Carrasco, Carolina; Xu, Xin; Carrascosa, José L; Gómez-Herrero, Julio; José de Pablo, Pedro; Raman, Arvind

    2009-08-18

    We study the physical origins of phase contrast in dynamic atomic force microscopy (dAFM) in liquids where low-stiffness microcantilever probes are often used for nanoscale imaging of soft biological samples with gentle forces. Under these conditions, we show that the phase contrast derives primarily from a unique energy flow channel that opens up in liquids due to the momentary excitation of higher eigenmodes. Contrary to the common assumption, phase-contrast images in liquids using soft microcantilevers are often maps of short-range conservative interactions, such as local elastic response, rather than tip-sample dissipation. The theory is used to demonstrate variations in local elasticity of purple membrane and bacteriophage 29 virions in buffer solutions using the phase-contrast images.

  3. In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science.

    Science.gov (United States)

    Mayo, Sheridan C; Stevenson, Andrew W; Wilkins, Stephen W

    2012-05-24

    X-ray phase-contrast imaging and tomography make use of the refraction of X-rays by the sample in image formation. This provides considerable additional information in the image compared to conventional X-ray imaging methods, which rely solely on X-ray absorption by the sample. Phase-contrast imaging highlights edges and internal boundaries of a sample and is thus complementary to absorption contrast, which is more sensitive to the bulk of the sample. Phase-contrast can also be used to image low-density materials, which do not absorb X-rays sufficiently to form a conventional X-ray image. In the context of materials science, X-ray phase-contrast imaging and tomography have particular value in the 2D and 3D characterization of low-density materials, the detection of cracks and voids and the analysis of composites and multiphase materials where the different components have similar X-ray attenuation coefficients. Here we review the use of phase-contrast imaging and tomography for a wide variety of materials science characterization problems using both synchrotron and laboratory sources and further demonstrate the particular benefits of phase contrast in the laboratory setting with a series of case studies.

  4. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging

    Science.gov (United States)

    Willner, M.; Herzen, J.; Grandl, S.; Auweter, S.; Mayr, D.; Hipp, A.; Chabior, M.; Sarapata, A.; Achterhold, K.; Zanette, I.; Weitkamp, T.; Sztrókay, A.; Hellerhoff, K.; Reiser, M.; Pfeiffer, F.

    2014-04-01

    X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography.

  5. Origins of phase contrast in the atomic force microscope in liquids

    OpenAIRE

    Melcher, John; Carrasco, Carolina; Xu, Xianfan; Carrascosa, Jose L; Gomez-Herrero, Julio; Jose de Pablo, Pedro; Raman, Arvind

    2009-01-01

    We study the physical origins of phase contrast in dynamic atomic force microscopy (dAFM) in liquids where low-stiffness microcantilever probes are often used for nanoscale imaging of soft biological samples with gentle forces. Under these conditions, we show that the phase contrast derives primarily from a unique energy flow channel that opens up in liquids due to the momentary excitation of higher eigenmodes. Contrary to the common assumption, phase-contrast images in liquids using soft mic...

  6. Effects of iodinated contrast media on blood and endothelium

    International Nuclear Information System (INIS)

    Aspelin, Peter; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.; Molen, Aart J. van der

    2006-01-01

    The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media. (orig.)

  7. Effects of iodinated contrast media on blood and endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Aspelin, Peter [Karolinska Institute/Huddinge University Hospital, Division of Radiology, Centre for Surgical Sciences, Stockholm (Sweden); Stacul, Fulvio [Institute of Radiology, Trieste (Italy); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Sheffield Teaching Hospitals NHS Trust, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom); Molen, Aart J. van der [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands)

    2006-05-15

    The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media. (orig.)

  8. Abdominal trauma

    International Nuclear Information System (INIS)

    Giordany, B.R.

    1985-01-01

    Abdominal injury is an important cause of morbidity and mortality in childhood. Ten percent of trauma-related deaths are due to abdominal injury. Thousands of children are involved in auto accidents annually; many suffer severe internal injury. Child abuse is a second less frequent but equally serious cause of internal abdominal injury. The descriptions of McCort and Eisenstein and their associates in the 1960s first brought to attention the frequency and severity of visceral injury as important manifestations of the child abuse syndrome. Blunt abdominal trauma often causes multiple injuries; in the past, many children have been subjected to exploratory surgery to evaluate the extent of possible hidden injury. Since the advent of noninvasive radiologic imaging techniques including radionuclide scans and ultrasound and, especially, computed tomography (CT), the radiologist has been better able to assess (accurately) the extent of abdominal injury and thus allow conservative therapy in many cases. Penetrating abdominal trauma occurs following gunshot wounds, stabbing, and other similar injury. This is fortunately, a relatively uncommon occurrence in most pediatric centers and will not be discussed specifically here, although many principles of blunt trauma diagnosis are valid for evaluation of penetrating abdominal trauma. If there is any question that a wound has extended intraperitonelly, a sinogram with water-soluble contrast material allows quick, accurate diagnosis. The presence of large amounts of free intraperitoneal gas suggests penetrating injury to the colon or other gas-containing viscus and is generally considered an indication for surgery

  9. Efficacy of pamiray as a nonionic intravenous contrast material; experimental study suing normal rabbits

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Tae Kyoung; Kim, Seung Hyup; Kim, Hyun Beom; Kim, Se Hyung; Hwang, Sung Il; Yeon, Kyung Mo

    2000-01-01

    To evaluate the efficacy of Pamiray as an intravenous nonionic contrast material by comparing it with an established nonionic contrast material (Iopamiro). Forty adult New Zealand white rabbits weighing about 3.0 kg were used in this study. Aortography and urography (scout, 5, 15 and 30 minutes delay after injection) were performed in ten rabbits with Pamiray (370 mgI/mL) and in other ten rabbits with Iopamiro (370 mgI/mL). All twenty rabbits underwent abdominal triple-phase spiral CT before and 5 and 30 seconds after injection of the contrast material. The degree of contrast enhancement seen on aortograms and intravenous urograms was determined using a three-point scale by two radiologists, who reached a consensus. CT attenuation expressed in Hounsfield units (HU) was measured using the regions of interest (ROIs) facility in the liver, bilateral kidneys, aorta, portal vein, and inferior vena cave. The Mann-Whitney U test was used in image evaluation for intergroup comparisons. There was no significant difference between the two groups in the degree of contrast enhancement seen on aortograms. In urography, however, Iopamiro was superior to Pamiray in demonstrating calyces of the right kidney on 15-minute delay images and Pamiray was superior to Iopamiro in demonstrating the right ureter and the renal pelvis on five minute-delay images and the left ureter on 30 minutes delay (p less than 0.05). Peak enhancement of the aorta during the first phase of abdominal CT was higher in the group in which Pamiray was used. When normal rabbits were used for aortography, abdominal CT, and urography, Pamiray provided more effective contrast enhancement than a previously used nonionic contrast material, namely Iopamiro. There were, however, slight differences in the enhancement features of renal calyces and ureters seen on 5- and 15-minute urograms. (author)

  10. Characterization of a high-energy in-line phase contrast tomosynthesis prototype.

    Science.gov (United States)

    Wu, Di; Yan, Aimin; Li, Yuhua; Wong, Molly D; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2015-05-01

    In this research, a high-energy in-line phase contrast tomosynthesis prototype was developed and characterized through quantitative investigations and phantom studies. The prototype system consists of an x-ray source, a motorized rotation stage, and a CMOS detector with a pixel pitch of 0.05 mm. The x-ray source was operated at 120 kVp for this study, and the objects were mounted on the rotation stage 76.2 cm (R1) from the source and 114.3 cm (R2) from the detector. The large air gap between the object and detector guarantees sufficient phase-shift effects. The quantitative evaluation of this prototype included modulation transfer function and noise power spectrum measurements conducted under both projection mode and tomosynthesis mode. Phantom studies were performed including three custom designed phantoms with complex structures: a five-layer bubble wrap phantom, a fishbone phantom, and a chicken breast phantom with embedded fibrils and mass structures extracted from an ACR phantom. In-plane images of the phantoms were acquired to investigate their image qualities through observation, intensity profile plots, edge enhancement evaluations, and/or contrast-to-noise ratio calculations. In addition, the robust phase-attenuation duality (PAD)-based phase retrieval method was applied to tomosynthesis for the first time in this research. It was utilized as a preprocessing method to fully exhibit phase contrast on the angular projection before reconstruction. The resolution and noise characteristics of this high-energy in-line phase contrast tomosynthesis prototype were successfully investigated and demonstrated. The phantom studies demonstrated that this imaging prototype can successfully remove the structure overlapping in phantom projections, obtain delineate interfaces, and achieve better contrast-to-noise ratio after applying phase retrieval to the angular projections. This research successfully demonstrated a high-energy in-line phase contrast tomosynthesis

  11. Phase-contrast X-ray imaging using an X-ray interferometer for biological imaging

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi; Koyama, Ichiro [Tokyo Univ., Dept. of Applied Physics, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Inst. of Clinical Medicine, Tsukuba, Ibaraki (Japan); Yoneyama, Akio [Hitachi Ltd., Advanced Research Laboratory, Saitama (Japan)

    2002-04-01

    The potential of phase-contrast X-ray imaging using an X-ray interferometer is discussed comparing with other phase-contrast X-ray imaging methods, and its principle of contrast generation is presented including the case of phase-contrast X-ray computed tomography. The status of current instrumentation is described and perspectives for practical applications are discussed. (author)

  12. Da Vinci-assisted abdominal cerclage.

    Science.gov (United States)

    Barmat, Larry; Glaser, Gretchen; Davis, George; Craparo, Frank

    2007-11-01

    To report the first placement of an abdominal cervicoisthmic cerclage using the da Vinci robot. Case report. Tertiary-care hospital. A 39-year-old female with a history of cervical insufficiency who required a cerclage and was not a candidate for transvaginal cerclage placement. Abdominal cervicoisthmic cerclage placement using the da Vinci robot. Ability to safely and successfully place an abdominal cerclage using the da Vinci robot. Abdominal cerclage was successfully placed using the da Vinci robot. The patient had minimal blood loss and was discharged to home on the same day as surgery. Da Vinci robot-assisted abdominal cerclage placement is an innovative application of robotic surgery and may alter the standard of care for women who require this surgery.

  13. Lycopene, Lutein and Zeaxanthin May Reduce Faecal Blood, Mucus and Pus but not Abdominal Pain in Individuals with Ulcerative Colitis.

    Science.gov (United States)

    Głąbska, Dominika; Guzek, Dominika; Zakrzewska, Paulina; Włodarek, Dariusz; Lech, Gustaw

    2016-09-30

    The main symptom of ulcerative colitis is diarrhoea, which is often accompanied by painful tenesmus and faecal blood and mucus. It sometimes co-occurs with abdominal pain, fever, feeling of fatigue, loss of appetite and weight loss. Some dietary factors have been indicated as important in the treatment of ulcerative colitis. The aim of the study was to analyse the association between retinoid intake (total vitamin A, retinol, β-carotene, α-carotene, β-cryptoxanthin, lycopene, lutein and zeaxanthin) and ulcerative colitis symptoms (abdominal pain, faecal blood, faecal mucus, faecal pus) in individuals with ulcerative colitis in remission. Assessment of diet was based on self-reported data from each patient's dietary records taken over a period of three typical, random days (2 weekdays and 1 day of the weekend). A total of 56 individuals with ulcerative colitis in remission (19 males and 37 females) were recruited for the study. One in every four individuals with ulcerative colitis in remission was characterised as having inadequate vitamin A intake. Higher lycopene, lutein and zeaxanthin intakes in individuals with ulcerative colitis in remission were associated with lower faecal blood, mucus and pus but not with lower incidence of abdominal pain. Higher carotene intake in individuals with ulcerative colitis in remission may contribute to higher incidence of faecal mucus. Optimising intake of specific retinoids may enhance disease control in individuals with ulcerative colitis. Prospective studies, including patient reported and objective outcomes, are required to confirm this.

  14. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    Science.gov (United States)

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Right-sided phase abnormalities on gated blood pool ventriculography: Demonstration of six different patterns

    International Nuclear Information System (INIS)

    Bahar, R.H.; Abdel-Dayem, H.M.; Ziada, G.; Al-Suhali, A.; Constantinides, C.; Nair, K.M.

    1986-01-01

    Phase pattern abnormalities on multiple gated blood pool ventriculography are better reported for the left ventricle (LV) than for the right side of the heart. In a study of 92 patients who also underwent contrast ventriculography, the authors identified six different patterns of right-sided phase abnormalities and their causes: right bundle-branch block, causing delayed phase in the entire right ventricle (RV); ischemic right coronary artery disease, causing delayed phase in the inferior RV wall; pericardial effusion, causing an L-shaped area of delayed phase to the right of the septum and below the LV; pulmonary hypertension, causing delayed phase in the pulmonary infundibulum; tricuspid regurgitation, causing a crescentic area of delayed phase around and below the right RV and extending below the LV as well, and atrial septal defect causing an abnormally large auricular phase

  16. Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study

    Science.gov (United States)

    Wu, Di; Donovan Wong, Molly; Li, Yuhua; Fajardo, Laurie; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2017-12-01

    The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.

  17. Computed tomographic manifestations of abdominal and pelvic venous collaterals

    International Nuclear Information System (INIS)

    Pagani, J.J.; Thomas, J.L.; Bernardino, M.E.

    1982-01-01

    Obstruction of blood flow through the inferior vena cava and portal vein may produce venous collaterals. These include the paravertebral venous system and its communications with the ascending lumbar veins and azygous/hemiazygous system; gonadal, periureteric, and other retroperitoneal veins; abdominal wall veins; hemorrhoidal venous plexus; and the portal venous system. The anatomic location of these vessels is discussed. Computed tomography demonstrates them as round or tubular structures that are isodens when compared with other venous structures following contrast material administration. Techniques of examination and methods of differentiation of these vascular structures from other abnormalities, especially lymphadenopathy, are discussed

  18. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    International Nuclear Information System (INIS)

    Zhou, Yifang; Scott, Alexander II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-01-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R 2   >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented. (paper)

  19. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    Science.gov (United States)

    Zhou, Yifang; Scott, Alexander, II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-10-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R^2  >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented.

  20. Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation

    International Nuclear Information System (INIS)

    Besseghini, S.; Stortiero, F.; Carcano, G.; Villa, E.; Mancini, L.; Tromba, G.; Zanini, F.; Montanari, F.; Airoldi, G.

    2003-01-01

    Phase contrast radiography (PCR) is a quite novel technique that is collecting increasing attention due to the possibility to obtain image information in presence of very small differences in the densities of the materials under analysis. Phase contrast imaging (PCI) has some specific advantage when compared with common microscopic techniques: (a) no special preparation of the sample is needed (b) the simultaneously investigated area is very large and (c) it allows the setting up of complex experimental apparatus. The results here presented are a good evidence of these three advantages. In this paper, we report on the application of phase contrast imaging in the study of the phase evolution during pseudoelastic transformation in the NiTiCu shape memory alloys (SMAs). The investigation was undertaken with the aim to identify some modification of the structure taking place at the end of the transformation plateau in the pseudoelastic behaviour of the alloy

  1. Red blood cell labeling with technetium-99m. Effect of radiopaque contrast agents

    International Nuclear Information System (INIS)

    Finkel, J.; Chervu, L.R.; Bernstein, R.G.; Srivastava, S.C.

    1988-01-01

    Radiographic contrast agents have been reported in the literature to interfere significantly with red blood cell (RBC) labeling in vivo by Tc-99m. Moreover, in the presence of contrast agents, red cells have been known to undergo significant morphologic changes. These observations led to the current RBC labeling study in patients (N = 25) undergoing procedures with the administration of contrast media. Before and after contrast administration, blood samples were drawn from each patient into vacutainer tubes containing heparin and RBC labeling was performed using 1-ml aliquots of these samples following the Brookhaven National Laboratory protocol. The differences in average percentage labeling yield with and without contrast media were not significant. In vivo labeling in hypertensive rats with administration of contrast media up to 600 mg likewise consistently gave high labeling yields at all concentrations. Purported alterations in cell labeling attributed to contrast agents are not reflected in these studies, and other pathophysiologic factors need to be identified to substantiate the previous reports. In vitro study offers a potentially useful and simple method to delineate effects of various agents on cell labeling

  2. Changing spleen size after blunt abdominal trauma

    International Nuclear Information System (INIS)

    Goodman, L.R.; Aprahamian, C.

    1989-01-01

    The authors studied the incidence and significance of splenic enlargement on serial CT after abdominal trauma. Spleen size and density in 44 trauma patients were studied with serial, contrast-enhanced Ct. In 58% of the patients, ≥ 10% enlargement of the spleen was seen on follow-up scans. Ten patients had >50% enlargement. In several, the initial density of the spleen was less than that of the liver. Spleen density returned to normal on subsequent scans. Correlations between splenic changes and clinical parameters (such as blood replacement, hypotension, and various trauma indexes) were weak. The author's study indicated that serial splenic enlargement was a physiologic return to normal after major trauma, not a pathologic condition requiring splenectomy

  3. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  4. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  5. Abdominal epilepsy as an unusual cause ofabdominal pain: A case ...

    African Journals Online (AJOL)

    Introduction: Abdominal pain, in etiology sometimes difficult to be defined, is a frequent complaint in childhood. Abdominal epilepsy is a rare cause of abdominal pain. Objectives: In this article, we report on 5 year old girl patient with abdominal epilepsy. Methods: Some investigations (stool investigation, routine blood tests, ...

  6. Abdominal compartment syndrome with acute reperfusion syndrome

    International Nuclear Information System (INIS)

    Maleeva, A.

    2017-01-01

    Abdominal compartment syndrome was recognized clinically in the 19th century when Marey and Burt observed its association with declines in respiratory function. Abdominal compartment syndrome is first used as a medical terminology from Fietsman in a case of ruptured abdominal aortic aneurysm. A condition caused by abnormally increased pressure within the abdomen. Causes of abdominal compartment syndrome include trauma, surgery, or infection. Common symptoms: abdominal distension, fast heart rate, insufficient urine production, or low blood pressure Medical procedure: nasogastric intubation Surgery: laparotomy Specialists: radiologist, primary care provider (PCP), surgeon, and emergency medicine doctor [6, 10]. Keywords: Stomach. Gastroparesis . Diabetes Mellitus [bg

  7. Abdominal MR: liver and pancreas

    International Nuclear Information System (INIS)

    Bartolozzi, C.; Lencioni, R.; Donati, F.; Cioni, D.

    1999-01-01

    Following the introduction of rapid, high-quality scan techniques and the development of new, tissue-specific contrast agents, the applications of MRI for abdominal imaging are experiencing unprecedented growth. This article examines the current status of liver and pancreatic MRI, highlighting technical and methodological approach, use of contrast agents, and main clinical applications. The MRI technique appears to be the ideal diagnostic tool for detection and characterization of benign and malignant liver neoplasms, and for evaluating tumor response after nonsurgical treatments. Dynamic imaging after bolus injection of a gadolinium chelate is currently a fundamental component of an MRI examination of the liver in many instances. Optimal dynamic scanning depends on the use of a multisection spoiled gradient-echo technique that allows one to image the entire region of interest during a single suspended respiration. Images are obtained during four phases relative to the injection of the contrast agent: precontrast, arterial (pre-sinusoidal), portal (sinusoidal), and delayed (extracellular) phase. Liver-specific contrast agents, including hepatobiliary agents and reticuloendothelial system-targeted iron oxide particles, however, may offer advantages over gadolinium chelates in some clinical settings. Computed tomography is still preferred to MRI for imaging the pancreas. However, state-of-the-art MRI may currently be at least as accurate as spiral CT for depiction of inflammatory and neoplastic pancreatic diseases. Moreover, MRI has the advantage of allowing simultaneous investigation of the biliary tree, owing to cholangiopancreatography techniques. Hence, a comprehensive assessment of most pancreatic diseases can be achieved with a single examination. (orig.)

  8. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents – A phantom study

    International Nuclear Information System (INIS)

    Bunck, Alexander C.; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C.; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R.

    2012-01-01

    Purpose: 4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. Materials and methods: 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. Results: In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n = 14) than by 2D phase contrast flow imaging (n = 10). Conclusions: 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type

  9. Low-dose quantitative phase contrast medical CT

    Science.gov (United States)

    Mittone, A.; Bravin, A.; Coan, P.

    2018-02-01

    X-ray computed tomography (CT) is a powerful and routinely used clinical diagnostic technique, which is well tolerated by patients, and which provides high-resolution images and volumetric information about the body. However, two important limitations still affect this examination procedure: (1) its low sensitivity with respect to soft tissues, and (2) the hazards associated with x-ray exposure. Conventional radiology is based on the detection of the different photon absorption properties that characterize biological tissues, and thus the obtainable image contrast from soft and/or similar tissues is intrinsically limited. In this scenario, x-ray phase contrast imaging (XPCI) has been extensively tested and proven to overcome some of the main issues surrounding standard x-ray imaging. In addition to the absorption signal, XPCI relies on detecting the phase shifts induced by an object. Interestingly, as the order of magnitude of the phase contrast is higher than that of absorption, XPCI can, in principle, offer higher sensitivity at lower radiation doses. However, other technical aspects may counterbalance this gain, and an optimized setup and image processing solutions need to be implemented. The work presented here describes the strategies and developments we have realized, with the aim of controlling the radiation dose for the highly sensitive and quantitative XPCI-CT. Different algorithms for the phase retrieval and CT reconstruction of the XPCI data are presented. The CT algorithms we have implemented, namely the equally sloped tomography and the dictionary learning method, allow the image quality to be preserved while reducing the number of angular projections required by a factor of five. The results applied to breast imaging report accurate reconstructions at clinically compatible doses of the 3D distribution of the refractive properties of full human organs obtained by using three different phase retrieval methods. The described methodologies and the

  10. MR flow velocity measurement using 2D phase contrast, assessment of imaging parameters

    International Nuclear Information System (INIS)

    Akata, Soichi; Fukushima, Akihiro; Abe, Kimihiko; Darkanzanli, A.; Gmitro, A.F.; Unger, E.C.; Capp, M.P.

    1999-01-01

    The two-dimensional (2D) phase contrast technique using balanced gradient pulses is utilized to measure flow velocities of cerebrospinal fluid and blood. Various imaging parameters affect the accuracy of flow velocity measurements to varying degrees. Assessment of the errors introduced by changing the imaging parameters are presented and discussed in this paper. A constant flow phantom consisting of a pump, a polyethylene tube and a flow meter was assembled. A clinical 1.5 Tesla MR imager was used to perform flow velocity measurements. The phase contrast technique was used to estimate the flow velocity of saline through the phantom. The effects of changes in matrix size, flip angle, flow compensation, and velocity encoding (VENC) value were tested in the pulse sequence. Gd-DTPA doped saline was used to study the effect of changing T1 on the accuracy of flow velocity measurement. Matrix size (within practical values), flip angle, and flow compensation had minimum impact on flow velocity measurements. T1 of the solution also had no effect on the accuracy of measuring the flow velocity. On the other hand, it was concluded that errors as high as 20% can be expected in the flow velocity measurements if the VENC value is not properly chosen. (author)

  11. MR flow velocity measurement using 2D phase contrast, assessment of imaging parameters

    Energy Technology Data Exchange (ETDEWEB)

    Akata, Soichi; Fukushima, Akihiro; Abe, Kimihiko [Tokyo Medical Coll. (Japan); Darkanzanli, A.; Gmitro, A.F.; Unger, E.C.; Capp, M.P.

    1999-11-01

    The two-dimensional (2D) phase contrast technique using balanced gradient pulses is utilized to measure flow velocities of cerebrospinal fluid and blood. Various imaging parameters affect the accuracy of flow velocity measurements to varying degrees. Assessment of the errors introduced by changing the imaging parameters are presented and discussed in this paper. A constant flow phantom consisting of a pump, a polyethylene tube and a flow meter was assembled. A clinical 1.5 Tesla MR imager was used to perform flow velocity measurements. The phase contrast technique was used to estimate the flow velocity of saline through the phantom. The effects of changes in matrix size, flip angle, flow compensation, and velocity encoding (VENC) value were tested in the pulse sequence. Gd-DTPA doped saline was used to study the effect of changing T1 on the accuracy of flow velocity measurement. Matrix size (within practical values), flip angle, and flow compensation had minimum impact on flow velocity measurements. T1 of the solution also had no effect on the accuracy of measuring the flow velocity. On the other hand, it was concluded that errors as high as 20% can be expected in the flow velocity measurements if the VENC value is not properly chosen. (author)

  12. Lycopene, Lutein and Zeaxanthin May Reduce Faecal Blood, Mucus and Pus but not Abdominal Pain in Individuals with Ulcerative Colitis

    Science.gov (United States)

    Głąbska, Dominika; Guzek, Dominika; Zakrzewska, Paulina; Włodarek, Dariusz; Lech, Gustaw

    2016-01-01

    Background: The main symptom of ulcerative colitis is diarrhoea, which is often accompanied by painful tenesmus and faecal blood and mucus. It sometimes co-occurs with abdominal pain, fever, feeling of fatigue, loss of appetite and weight loss. Some dietary factors have been indicated as important in the treatment of ulcerative colitis. The aim of the study was to analyse the association between retinoid intake (total vitamin A, retinol, β-carotene, α-carotene, β-cryptoxanthin, lycopene, lutein and zeaxanthin) and ulcerative colitis symptoms (abdominal pain, faecal blood, faecal mucus, faecal pus) in individuals with ulcerative colitis in remission. Methods: Assessment of diet was based on self-reported data from each patient’s dietary records taken over a period of three typical, random days (2 weekdays and 1 day of the weekend). Results: A total of 56 individuals with ulcerative colitis in remission (19 males and 37 females) were recruited for the study. One in every four individuals with ulcerative colitis in remission was characterised as having inadequate vitamin A intake. Higher lycopene, lutein and zeaxanthin intakes in individuals with ulcerative colitis in remission were associated with lower faecal blood, mucus and pus but not with lower incidence of abdominal pain. Higher carotene intake in individuals with ulcerative colitis in remission may contribute to higher incidence of faecal mucus. Conclusions: Optimising intake of specific retinoids may enhance disease control in individuals with ulcerative colitis. Prospective studies, including patient reported and objective outcomes, are required to confirm this. PMID:27706028

  13. Zernike phase contrast cryo-electron tomography of whole bacterial cells.

    Science.gov (United States)

    Guerrero-Ferreira, Ricardo C; Wright, Elizabeth R

    2014-01-01

    Cryo-electron tomography (cryo-ET) provides three-dimensional (3D) structural information of bacteria preserved in a native, frozen-hydrated state. The typical low contrast of tilt-series images, a result of both the need for a low electron dose and the use of conventional defocus phase-contrast imaging, is a challenge for high-quality tomograms. We show that Zernike phase-contrast imaging allows the electron dose to be reduced. This limits movement of gold fiducials during the tilt series, which leads to better alignment and a higher-resolution reconstruction. Contrast is also enhanced, improving visibility of weak features. The reduced electron dose also means that more images at more tilt angles could be recorded, further increasing resolution. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Detoxification in Abdominal Sepsis

    Directory of Open Access Journals (Sweden)

    A. F. Potapov

    2005-01-01

    Full Text Available Objective. To comparatively analyze the efficiency of methods for extracorporeal detoxification (ED of the body in abdominal sepsis (AS and to choose the optimum detoxifying methods in relation to the level of endotoxicosis.Material and methods. 56 patients (41 males and 15 females; mean age 39.4±12.2 years with surgical abdominal infection of various genesis, complicated by the development of sepsis whose treatment included ED methods, were examined. The level of intoxication and the efficiency of detoxification were evaluated by general clinical and biochemical blood parameters, the leukocytic intoxication index, the levels of low and medium molecular-weight substances in the body’s media. Hemosorption, plasmapheresis, hemodialysis, hemodiafiltration, and hemofiltration were used for detoxification.Results. Surgical abdominal infection is accompanied by endotoxemia that has no clear nosological specificity, but it depends on the pattern of a clinical course of the disease and is most pronounced in the septic syndrome. In AS, 80.4% of the patients are observed to have an irreversible decompensation phase and a terminal degree of endotoxicosis, which require detoxification. The use of different ED methods according to the level of intoxication may reduce the level of endotoxicosis and yield a persistent beneficial effect in 85.2% of cases of its application. Conclusion. Filtration and dialysis techniques (hemodialysis, hemofiltration, and hemodiafiltration are the methods of choice in AS. Hemosorption and plasmapheresis may be recommended for use at the early stages of endotoxicosis development and in preserved renal excretory function.

  15. Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples

    Science.gov (United States)

    Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia

    2015-01-01

    X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638

  16. X-ray phase contrast imaging: From synchrotrons to conventional sources

    International Nuclear Information System (INIS)

    Olivo, A.; Castelli, E.

    2014-01-01

    Phase-based approaches can revolutionize X-ray imaging and remove its main limitation: poor image contrast arising from low attenuation differences. They exploit the unit decrement of the real part of the refractive index, typically 1000 times larger than the imaginary part driving attenuation. This increases the contrast of all details, and enables the detection of features classically considered 'X-ray invisible'. Following pioneering experiments dating back to the mid-sixties, X-ray phase contrast imaging 'exploded' in the mid-nineties, when third generation synchrotron sources became more widely available. Applications were proposed in fields as diverse as material science, palaeontology, biology, food science, cultural heritage preservation, and many others. Among these applications, medicine has been constantly considered the most important; among medical applications, mammography is arguably the one that attracted most attention. Applications to mammography were pioneered by the SYRMEP (SYnchrotron Radiation for MEdical Physics) group in Trieste, which was already active in the area through a combination of innovative ways to do imaging at synchrotrons and development of novel X-ray detectors. This pioneering phase led to the only clinical experience of phase contrast mammography on human patients, and spawned a number of ideas as to how these advances could be translated into clinical practice.

  17. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma

    DEFF Research Database (Denmark)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre

    2017-01-01

    = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters......OBJECTIVES: The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS: Dynamic contrast-enhanced computed...

  18. Monte Carlo simulation of grating-based neutron phase contrast imaging at CPHS

    International Nuclear Information System (INIS)

    Zhang Ran; Chen Zhiqiang; Huang Zhifeng; Xiao Yongshun; Wang Xuewu; Wie Jie; Loong, C.-K.

    2011-01-01

    Since the launching of the Compact Pulsed Hadron Source (CPHS) project of Tsinghua University in 2009, works have begun on the design and engineering of an imaging/radiography instrument for the neutron source provided by CPHS. The instrument will perform basic tasks such as transmission imaging and computerized tomography. Additionally, we include in the design the utilization of coded-aperture and grating-based phase contrast methodology, as well as the options of prompt gamma-ray analysis and neutron-energy selective imaging. Previously, we had implemented the hardware and data-analysis software for grating-based X-ray phase contrast imaging. Here, we investigate Geant4-based Monte Carlo simulations of neutron refraction phenomena and then model the grating-based neutron phase contrast imaging system according to the classic-optics-based method. The simulated experimental results of the retrieving phase shift gradient information by five-step phase-stepping approach indicate the feasibility of grating-based neutron phase contrast imaging as an option for the cold neutron imaging instrument at the CPHS.

  19. A Newborn With Abdominal Pain.

    Science.gov (United States)

    Alwan, Riham; Drake, Meredith; Gurria Juarez, Juan; Emery, Kathleen H; Shaaban, Aimen F; Szabo, Sara; Sobolewski, Brad

    2017-11-01

    A previously healthy 3-week-old boy presented with 5 hours of marked fussiness, abdominal distention, and poor feeding. He was afebrile and well perfused. His examination was remarkable for localized abdominal tenderness and distention. He was referred to the emergency department in which an abdominal radiograph revealed gaseous distention of the bowel with a paucity of gas in the pelvis. Complete blood cell count and urinalysis were unremarkable. His ongoing fussiness and abnormal physical examination prompted consultation with surgery and radiology. Our combined efforts ultimately established an unexpected diagnosis. Copyright © 2017 by the American Academy of Pediatrics.

  20. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  1. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    International Nuclear Information System (INIS)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  2. Investigation of the imaging quality of synchrotron-based phase-contrast mammographic tomography

    International Nuclear Information System (INIS)

    Gureyev, T E; Mayo, S C; Nesterets, Ya I; Mohammadi, S; Menk, R H; Arfelli, F; Tromba, G; Lockie, D; Pavlov, K M; Kitchen, M J; Zanconati, F; Dullin, C

    2014-01-01

    We report the results of a systematic study of phase-contrast x-ray computed tomography in the propagation-based and analyser-based modes using specially designed phantoms and excised breast tissue samples. The study is aimed at the quantitative evaluation and subsequent optimization, with respect to detection of small tumours in breast tissue, of the effects of phase contrast and phase retrieval on key imaging parameters, such as spatial resolution, contrast-to-noise ratio, x-ray dose and a recently proposed ‘intrinsic quality’ characteristic which combines the image noise with the spatial resolution. We demonstrate that some of the methods evaluated in this work lead to substantial (more than 20-fold) improvement in the contrast-to-noise and intrinsic quality of the reconstructed tomographic images compared with conventional techniques, with the measured characteristics being in good agreement with the corresponding theoretical estimations. This improvement also corresponds to an approximately 400-fold reduction in the x-ray dose, compared with conventional absorption-based tomography, without a loss in the imaging quality. The results of this study confirm and quantify the significant potential benefits achievable in three-dimensional mammography using x-ray phase-contrast imaging and phase-retrieval techniques. (paper)

  3. Visualizing Typical Features of Breast Fibroadenomas Using Phase-Contrast CT: An Ex-Vivo Study

    Science.gov (United States)

    Grandl, Susanne; Willner, Marian; Herzen, Julia; Sztrókay-Gaul, Anikó; Mayr, Doris; Auweter, Sigrid D.; Hipp, Alexander; Birnbacher, Lorenz; Marschner, Mathias; Chabior, Michael; Reiser, Maximilian; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin

    2014-01-01

    Background Fibroadenoma is the most common benign solid breast lesion type and a very common cause for histologic assessment. To justify a conservative therapy, a highly specific discrimination between fibroadenomas and other breast lesions is crucial. Phase-contrast imaging offers improved soft-tissue contrast and differentiability of fine structures combined with the potential of 3-dimensional imaging. In this study we assessed the potential of grating-based phase-contrast CT imaging for visualizing diagnostically relevant features of fibroadenomas. Materials and Methods Grating-based phase-contrast CT was performed on six ex-vivo formalin-fixed breast specimens containing a fibroadenoma and three samples containing benign changes that resemble fibroadenomas using Talbot Lau interferometry and a polychromatic X-ray source. Phase-contrast and simultaneously acquired absorption-based 3D-datasets were manually matched with corresponding histological slices. The visibility of diagnostically valuable features was assessed in comparison with histology as the gold-standard. Results In all cases, matching of grating-based phase-contrast CT images and histology was successfully completed. Grating-based phase-contrast CT showed greatly improved differentiation of fine structures and provided accurate depiction of strands of fibrous tissue within the fibroadenomas as well as of the diagnostically valuable dilated, branched ductuli of the fibroadenomas. A clear demarcation of tumor boundaries in all cases was provided by phase- but not absorption-contrast CT. Conclusions Pending successful translation of the technology to a clinical setting and considerable reduction of the required dose, the data presented here suggest that grating-based phase-contrast CT may be used as a supplementary non-invasive diagnostic tool in breast diagnostics. Phase-contrast CT may thus contribute to the reduction of false positive findings and reduce the recall and core biopsy rate in population

  4. Combined fluorescence and phase contrast imaging at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Hornberger, B.; Feser, M.; Jacobsen, C.; Vogt, S.; Legnini, D.; Paterson, D.; Rehak, P.; DeGeronimo, G.; Palmer, B.M.; Experimental Facilities Division; State Univ. of New York at Stony Brook Univ.; BNL; Univ. of Vermont

    2006-01-01

    X-ray fluorescence microprobes excel at detecting and quantifying trace metals in biological and environmental science samples, but typically do not detect low Z elements such as carbon and nitrogen. Therefore, it is hard to put the trace metals into context with their natural environment. We are implementing phase contrast capabilities with a segmented detector into several microprobes at the Advanced Photon Source (APS) to address this problem. Qualitative differential phase contrast images from a modified soft x-ray detector already provide very useful information for general users. We are also implementing a quantitative method to recover the absolute phase shift by Fourier filtering detector images. New detectors are under development which are optimized for the signal levels present at the APS. In this paper, we concentrate on fundamental signal to noise considerations comparing absorption and differential phase contrast

  5. Non-invasive estimation of blood pressure using ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using...

  6. Rational examination of the greater abdominal veins with 2D-TOF- and turbo-spin-echo sequences

    International Nuclear Information System (INIS)

    Lutterbey, G.; Sommer, T.; Keller, E.; Kuhl, C.; Schild, H.H.

    1998-01-01

    Purpose: Development of a fast and reliable protocol for the detection and exclusion of abdominal venous thrombosis with an optimised T 2 -TSE- and 2D-TOF sequence. Results: The most effective combination of strong flow-void phenomena, signal/noise ratio and scan time was found with the following parameters: T E 120 ms, T R 2000 ms, 5 mm slice gap. In the patient group two complete and two partial thromboses were diagnosed with both sequences. One wrong positive thrombosis occurred in a stenotic anastomosis with the 2D-inflow sequence. Conclusion: With optimum parameters the T 2 -TSE sequence produces a strong 'flow-void' phenomenon suitable for 'black-blood'-MRA. The use of this sequence alone or in combination with 2D-inflow MRA, if 'bright-blood' MRA is recommended, allows a reliable evaluation of thrombosis in abdominal veins without high-tech MRA equipment and contrast media. (orig./AJ) [de

  7. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  8. Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance.

    LENUS (Irish Health Repository)

    McLaughlin, P D

    2014-04-01

    The aim was to assess the performance of low-dose non-contrast CT of the urinary tract (LD-CT) acquired at radiation exposures close to that of abdominal radiography using adaptive statistical iterative reconstruction (ASiR).

  9. Intravenous contrast injection significantly affects bone mineral density measured on CT

    Energy Technology Data Exchange (ETDEWEB)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology and Internal Medicine-Geriatrics, Postbus 85500, Postbox: E.03.511, GA, Utrecht (Netherlands)

    2014-09-05

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  10. Intravenous contrast injection significantly affects bone mineral density measured on CT

    International Nuclear Information System (INIS)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de

    2015-01-01

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  11. Phase shift extraction and wavefront retrieval from interferograms with background and contrast fluctuations

    International Nuclear Information System (INIS)

    Liu, Qian; Wang, Yang; He, Jianguo; Ji, Fang

    2015-01-01

    The fluctuations of background and contrast cause measurement errors in the phase-shifting technique. To extract the phase shifts from interferograms with background and contrast fluctuations, an iterative algorithm is represented. The phase shifts and wavefront phase are calculated in two individual steps with the least-squares method. The fluctuation factors are determined when the phase shifts are calculated, and the fluctuations are compensated when the wavefront phase is calculated. The advantage of the algorithm lies in its ability to extract phase shifts from interferograms with background and contrast fluctuations converging stably and rapidly. Simulations and experiments verify the effectiveness and reliability of the proposed algorithm. The convergence accuracy and speed are demonstrated by the simulation results. The experiment results show its ability for suppressing phase retrieval errors. (paper)

  12. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Ogami, M; Kulkarni, R; Wang, H; Reif, R; Wang, R K [University of Washington, Department of Bioengineering, Seattle, Washington 98195 (United States)

    2014-08-31

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing. (laser biophotonics)

  13. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Science.gov (United States)

    Ogami, M.; Kulkarni, R.; Wang, H.; Reif, R.; Wang, R. K.

    2014-08-01

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing.

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  15. Investigating the limitations of single breath-hold renal artery blood flow measurements using spiral phase contrast MR with R-R interval averaging.

    Science.gov (United States)

    Steeden, Jennifer A; Muthurangu, Vivek

    2015-04-01

    1) To validate an R-R interval averaged golden angle spiral phase contrast magnetic resonance (RAGS PCMR) sequence against conventional cine PCMR for assessment of renal blood flow (RBF) in normal volunteers; and 2) To investigate the effects of motion and heart rate on the accuracy of flow measurements using an in silico simulation. In 20 healthy volunteers RAGS (∼6 sec breath-hold) and respiratory-navigated cine (∼5 min) PCMR were performed in both renal arteries to assess RBF. A simulation of RAGS PCMR was used to assess the effect of heart rate (30-105 bpm), vessel expandability (0-150%) and translational motion (x1.0-4.0) on the accuracy of RBF measurements. There was good agreement between RAGS and cine PCMR in the volunteer study (bias: 0.01 L/min, limits of agreement: -0.04 to +0.06 L/min, P = 0.0001). The simulation demonstrated a positive linear relationship between heart rate and error (r = 0.9894, P 100 bpm), or when there is significant motion (vessel expandability: >80%, vessel translation: >x2.2). © 2014 Wiley Periodicals, Inc.

  16. Recent advances in synchrotron-based hard x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Liu, Y; Nelson, J; Andrews, J C; Pianetta, P; Holzner, C

    2013-01-01

    Ever since the first demonstration of phase contrast imaging (PCI) in the 1930s by Frits Zernike, people have realized the significant advantage of phase contrast over conventional absorption-based imaging in terms of sensitivity to ‘transparent’ features within specimens. Thus, x-ray phase contrast imaging (XPCI) holds great potential in studies of soft biological tissues, typically containing low Z elements such as C, H, O and N. Particularly when synchrotron hard x-rays are employed, the favourable brightness, energy tunability, monochromatic characteristics and penetration depth have dramatically enhanced the quality and variety of XPCI methods, which permit detection of the phase shift associated with 3D geometry of relatively large samples in a non-destructive manner. In this paper, we review recent advances in several synchrotron-based hard x-ray XPCI methods. Challenges and key factors in methodological development are discussed, and biological and medical applications are presented. (paper)

  17. Recent advances in synchrotron-based hard x-ray phase contrast imaging

    Science.gov (United States)

    Liu, Y.; Nelson, J.; Holzner, C.; Andrews, J. C.; Pianetta, P.

    2013-12-01

    Ever since the first demonstration of phase contrast imaging (PCI) in the 1930s by Frits Zernike, people have realized the significant advantage of phase contrast over conventional absorption-based imaging in terms of sensitivity to ‘transparent’ features within specimens. Thus, x-ray phase contrast imaging (XPCI) holds great potential in studies of soft biological tissues, typically containing low Z elements such as C, H, O and N. Particularly when synchrotron hard x-rays are employed, the favourable brightness, energy tunability, monochromatic characteristics and penetration depth have dramatically enhanced the quality and variety of XPCI methods, which permit detection of the phase shift associated with 3D geometry of relatively large samples in a non-destructive manner. In this paper, we review recent advances in several synchrotron-based hard x-ray XPCI methods. Challenges and key factors in methodological development are discussed, and biological and medical applications are presented.

  18. Abdominal blood pool scintigraphy in the management of acute or intermittent gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kalff, V.; Kelly, M.J.; Dudley, F.; Metz, G.

    1983-01-01

    Gastrointestinal blood pool scintigraphy, using a modified in-vivo blood cell labelling technique with technetium-99, is a new, easily performed, non-invasive procedure. It is valuable in screening patients with acute or intermittent gastrointestinal blood loss in whom duodenoscopic and sigmoidoscopic findings are unhelpful. This paper reviews the value of this scintigraphic technique over the first eight months of its use in a major teaching hospital, and compares the results with other published data. If used and interpreted appropriately, scintigraphy is sensitive in detecting and localizing the bleeding site, and is very helpful in indicating the optimal timing of emergency contrast angiography

  19. Inter-observer agreement for abdominal CT in unselected patients with acute abdominal pain

    International Nuclear Information System (INIS)

    Randen, Adrienne van; Lameris, Wytze; Nio, C.Y.; Spijkerboer, Anje M.; Meier, Mark A.; Tutein Nolthenius, Charlotte; Smithuis, Frank; Stoker, Jaap; Bossuyt, Patrick M.; Boermeester, Marja A.

    2009-01-01

    The level of inter-observer agreement of abdominal computed tomography (CT) in unselected patients presenting with acute abdominal pain at the Emergency Department (ED) was evaluated. Two hundred consecutive patients with acute abdominal pain were prospectively included. Multi-slice CT was performed in all patients with intravenous contrast medium only. Three radiologists independently read all CT examinations. They recorded specific radiological features and a final diagnosis on a case record form. We calculated the proportion of agreement and kappa values, for overall, urgent and frequently occurring diagnoses. The mean age of the evaluated patients was 46 years (range 19-94), of which 54% were women. Overall agreement on diagnoses was good, with a median kappa of 0.66. Kappa values for specific urgent diagnoses were excellent, with median kappa values of 0.84, 0.90 and 0.81, for appendicitis, diverticulitis and bowel obstruction, respectively. Abdominal CT has good inter-observer agreement in unselected patients with acute abdominal pain at the ED, with excellent agreement for specific urgent diagnoses as diverticulitis and appendicitis. (orig.)

  20. Inter-observer agreement for abdominal CT in unselected patients with acute abdominal pain

    Energy Technology Data Exchange (ETDEWEB)

    Randen, Adrienne van [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Amsterdam (Netherlands); Lameris, Wytze [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Nio, C.Y.; Spijkerboer, Anje M.; Meier, Mark A.; Tutein Nolthenius, Charlotte; Smithuis, Frank; Stoker, Jaap [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Bossuyt, Patrick M. [University of Amsterdam, Department of Clinical Epidemiology, Biostatistics, and Bioinformatics, Academic Medical Center, Amsterdam (Netherlands); Boermeester, Marja A. [University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands)

    2009-06-15

    The level of inter-observer agreement of abdominal computed tomography (CT) in unselected patients presenting with acute abdominal pain at the Emergency Department (ED) was evaluated. Two hundred consecutive patients with acute abdominal pain were prospectively included. Multi-slice CT was performed in all patients with intravenous contrast medium only. Three radiologists independently read all CT examinations. They recorded specific radiological features and a final diagnosis on a case record form. We calculated the proportion of agreement and kappa values, for overall, urgent and frequently occurring diagnoses. The mean age of the evaluated patients was 46 years (range 19-94), of which 54% were women. Overall agreement on diagnoses was good, with a median kappa of 0.66. Kappa values for specific urgent diagnoses were excellent, with median kappa values of 0.84, 0.90 and 0.81, for appendicitis, diverticulitis and bowel obstruction, respectively. Abdominal CT has good inter-observer agreement in unselected patients with acute abdominal pain at the ED, with excellent agreement for specific urgent diagnoses as diverticulitis and appendicitis. (orig.)

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... for tumors as well as monitor response to chemotherapy. top of page How should I prepare? You ... of acute abdominal conditions in babies, such as vomiting or blood in stool. For some conditions, including ...

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... GI) contrast exams and ultrasound are preferred for evaluation of acute abdominal conditions in babies, such as ...

  3. Phase contrast imaging using a micro focus x-ray source

    Science.gov (United States)

    Zhou, Wei; Majidi, Keivan; Brankov, Jovan G.

    2014-09-01

    Phase contrast x-ray imaging, a new technique to increase the imaging contrast for the tissues with close attenuation coefficients, has been studied since mid 1990s. This technique reveals the possibility to show the clear details of the soft tissues and tumors in small scale resolution. A compact and low cost phase contrast imaging system using a conventional x-ray source is described in this paper. Using the conventional x-ray source is of great importance, because it provides the possibility to use the method in hospitals and clinical offices. Simple materials and components are used in the setup to keep the cost in a reasonable and affordable range.Tungsten Kα1 line with the photon energy 59.3 keV was used for imaging. Some of the system design details are discussed. The method that was used to stabilize the system is introduced. A chicken thigh bone tissue sample was used for imaging followed by the image quality, image acquisition time and the potential clinical application discussion. High energy x-ray beam can be used in phase contrast imaging. Therefore the radiation dose to the patients can be greatly decreased compared to the traditional x-ray radiography.

  4. Imaging of metastatic lymph nodes by X-ray phase-contrast micro-tomography.

    Directory of Open Access Journals (Sweden)

    Torben Haugaard Jensen

    Full Text Available Invasive cancer causes a change in density in the affected tissue, which can be visualized by x-ray phase-contrast tomography. However, the diagnostic value of this method has so far not been investigated in detail. Therefore, the purpose of this study was, in a blinded manner, to investigate whether malignancy could be revealed by non-invasive x-ray phase-contrast tomography in lymph nodes from breast cancer patients. Seventeen formalin-fixed paraffin-embedded lymph nodes from 10 female patients (age range 37-83 years diagnosed with invasive ductal carcinomas were analyzed by X-ray phase-contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study was that the diagnostic sensitivity of the image analysis for detecting malignancy was 100% and the specificity was 87%. The positive predictive value was 91% for detecting malignancy and the negative predictive value was 100%. We conclude that x-ray phase-contrast imaging can accurately detect density variations to obtain information regarding lymph node involvement previously inaccessible with standard absorption x-ray imaging.

  5. PHASE QUANTIZATION STUDY OF SPATIAL LIGHT MODULATOR FOR EXTREME HIGH-CONTRAST IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    Dou, Jiangpei; Ren, Deqing, E-mail: jpdou@niaot.ac.cn, E-mail: jiangpeidou@gmail.com [Physics and Astronomy Department, California State University Northridge, 18111 Nordhoff Street, Northridge, CA 91330 (United States)

    2016-11-20

    Direct imaging of exoplanets by reflected starlight is extremely challenging due to the large luminosity ratio to the primary star. Wave-front control is a critical technique to attenuate the speckle noise in order to achieve an extremely high contrast. We present a phase quantization study of a spatial light modulator (SLM) for wave-front control to meet the contrast requirement of detection of a terrestrial planet in the habitable zone of a solar-type star. We perform the numerical simulation by employing the SLM with different phase accuracy and actuator numbers, which are related to the achievable contrast. We use an optimization algorithm to solve the quantization problems that is matched to the controllable phase step of the SLM. Two optical configurations are discussed with the SLM located before and after the coronagraph focal plane mask. The simulation result has constrained the specification for SLM phase accuracy in the above two optical configurations, which gives us a phase accuracy of 0.4/1000 and 1/1000 waves to achieve a contrast of 10{sup -10}. Finally, we have demonstrated that an SLM with more actuators can deliver a competitive contrast performance on the order of 10{sup -10} in comparison to that by using a deformable mirror.

  6. Quantitative measurement of hemodynamics of inferior vena in healthy volunteers with phase-contrast MR imaging at 3.0 T

    International Nuclear Information System (INIS)

    Ruan Zhibing; Fan Guangming; Jiao Jun; Min Dingyu

    2014-01-01

    Objective: To explore the feasibility of quantitative hemodynamics measurement of inferior vena cava (IVC) in healthy volunteers with phase-contrast sequence on 3.0 T MR system (3.0 T PC-MRI), and to evaluate the relationship between IVC lumen area, blood flow, and velocity. Methods: Fifty healthy adult volunteers prospective underwent IVC PC-MRI at 3.0 T MR system. All volunteers were from our hospital for the routine chest or abdomen examinations, no heart disease and lung disease always, heart rate, blood pressure, electrocardiogram was in normal range, no abnormalities were found in clinical and abdominal imaging examinations, and IVC disease was excluded by ultrasonic examination. The area (A), mean velocity (MV), mean flux (MF), regurgitant fraction (RF) and time-flow curve of upper and middle segments of IVC during one cardiac cycle were observed. Independent samples t test was used to compare IVC lumen area and blood flow, velocity between different genders, different age groups (18 to 30 years old group, more than 30 years old group) and different phase velocity encoding value of IVC middle segment, one-way ANOVA was used to compare different phase velocity encoding value of IVC upper segment [(60, 80, 100)cm/s]. Pearson correlation coefficient and regression equation were used to evaluate the relationships between area, blood flow, and velocity. Results: Among 50 patients with successful completion of the examination, significant difference was found in A, MV, MF and RF between the different IVC segments. MF of the IVC middle segment were (37.94 ± 7.32) and (33.68 ± 6.65) ml/s in male (n=24) and female (n=26), respectively; significant difference was found in different genders (t=2.49, P=0.017). MF of upper segment and middle segments of IVC were (54.89 ± 10.98) and (38.29 ± 7.54) ml/s in 18 to 30 years old group (n=27), while MF of upper segment and the middle of IVC were (44.96 ± 8.49) and (32.65 ± 5.59) ml/s in older than 30 years old group (n=23

  7. Noninvasive 3D Structural Analysis of Arthropod by Synchrotron X-Ray Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Yao, S.; Zong, Y.; Fan, J.; Sun, Z.; Jiang, H.

    2015-01-01

    X-ray imaging techniques significantly advanced our understanding of materials and biology, among which phase contrast X-ray microscopy has obvious advantages in imaging biological specimens which have low contrast by conventional absorption contrast microscopy. In this paper, three-dimensional microstructure of arthropod with high contrast has been demonstrated by synchrotron X-ray in-line phase contrast tomography. The external morphology and internal structures of an earthworm were analyzed based upon tomographic reconstructions with and without phase retrieval. We also identified and characterized various fine structural details such as the musculature system, the digestive system, the nervous system, and the circulatory system. This work exhibited the high efficiency, high precision, and wide potential applications of synchrotron X-ray phase contrast tomography in nondestructive investigation of low-density materials and biology.

  8. Effects of patient-controlled abdominal compression on standing systolic blood pressure in adults with orthostatic hypotension.

    Science.gov (United States)

    Figueroa, Juan J; Singer, Wolfgang; Sandroni, Paola; Sletten, David M; Gehrking, Tonette L; Gehrking, Jade A; Low, Phillip; Basford, Jeffrey R

    2015-03-01

    To assess the effects of patient-controlled abdominal compression on postural changes in systolic blood pressure (SBP) associated with orthostatic hypotension (OH). Secondary variables included subject assessments of their preferences and the ease-of-use. Randomized crossover trial. Clinical research laboratory. Adults with neurogenic OH (N=13). Four maneuvers were performed: moving from supine to standing without abdominal compression; moving from supine to standing with either a conventional or an adjustable abdominal binder in place; application of subject-determined maximal tolerable abdominal compression while standing; and while still erect, subsequent reduction of abdominal compression to a level the subject believed would be tolerable for a prolonged period. The primary outcome variable included postural changes in SBP. Secondary outcome variables included subject assessments of their preferences and ease of use. Baseline median SBP in the supine position was not affected by mild (10mmHg) abdominal compression prior to rising (without abdominal compression: 146mmHg; interquartile range, 124-164mmHg; with the conventional binder: 145mmHg; interquartile range, 129-167mmHg; with the adjustable binder: 153mmHg, interquartile range, 129-160mmHg; P=.85). Standing without a binder was associated with an -57mmHg (interquartile range, -40 to -76mmHg) SBP decrease. Levels of compression of 10mmHg applied prior to rising with the conventional and adjustable binders blunted these drops to -50mmHg (interquartile range, -33 to -70mmHg; P=.03) and -46mmHg (interquartile range, -34 to -75mmHg; P=.01), respectively. Increasing compression to subject-selected maximal tolerance while standing did not provide additional benefit and was associated with drops of -53mmHg (interquartile range, -26 to -71mmHg; P=.64) and -59mmHg (interquartile range, -49 to -76mmHg; P=.52) for the conventional and adjustable binders, respectively. Subsequent reduction of compression to more

  9. Simulation of single grid-based phase-contrast x-ray imaging (g-PCXI)

    Energy Technology Data Exchange (ETDEWEB)

    Lim, H.W.; Lee, H.W. [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Cho, H.S., E-mail: hscho1@yonsei.ac.kr [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Je, U.K.; Park, C.K.; Kim, K.S.; Kim, G.A.; Park, S.Y.; Lee, D.Y.; Park, Y.O.; Woo, T.H. [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Lee, S.H.; Chung, W.H.; Kim, J.W.; Kim, J.G. [R& D Center, JPI Healthcare Co., Ltd., Ansan 425-833 (Korea, Republic of)

    2017-04-01

    Single grid-based phase-contrast x-ray imaging (g-PCXI) technique, which was recently proposed by Wen et al. to retrieve absorption, scattering, and phase-gradient images from the raw image of the examined object, seems a practical method for phase-contrast imaging with great simplicity and minimal requirements on the setup alignment. In this work, we developed a useful simulation platform for g-PCXI and performed a simulation to demonstrate its viability. We also established a table-top setup for g-PCXI which consists of a focused-linear grid (200-lines/in strip density), an x-ray tube (100-μm focal spot size), and a flat-panel detector (48-μm pixel size) and performed a preliminary experiment with some samples to show the performance of the simulation platform. We successfully obtained phase-contrast x-ray images of much enhanced contrast from both the simulation and experiment and the simulated contract seemed similar to the experimental contrast, which shows the performance of the developed simulation platform. We expect that the simulation platform will be useful for designing an optimal g-PCXI system. - Highlights: • It is proposed for the single grid-based phase-contrast x-ray imaging (g-PCXI) technique. • We implemented for a numerical simulation code. • The preliminary experiment with several samples to compare is performed. • It is expected to be useful to design an optimal g-PCXI system.

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging produces pictures of the internal organs and blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ...

  11. Observation of human tissue with phase-contrast x-ray computed tomography

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-05-01

    Human tissues obtained from cancerous kidneys fixed in formalin were observed with phase-contrast X-ray computed tomography (CT) using 17.7-keV synchrotron X-rays. By measuring the distributions of the X-ray phase shift caused by samples using an X-ray interferometer, sectional images that map the distribution of the refractive index were reconstructed. Because of the high sensitivity of phase- contrast X-ray CT, a cancerous lesion was differentiated from normal tissue and a variety of other structures were revealed without the need for staining.

  12. CT diagnosis of abdominal ectopic pheochromocytoma

    International Nuclear Information System (INIS)

    Zhang Yuping; Zhao Zhiying

    2010-01-01

    Objective: To discuss the value of CT in diagnosis of abdominal ectopic pheochromocytoma. Methods: CT findings of 5 cases surgically and pathologically proved with ectopic pheochromocytoma were retrospectively analyzed. Results: Soft tissue mass with light asymmetry enhancement was found between the abdominal aorta and the inferior vena ca-va in one case. 1 case was completely cystic with light enhancement of the cystwall located in front of the left side of the abdominal aorta. 1 case of large solid mass occurred between the renal hilum and the tail of pancreas, with irregular shape, unclear boundary, central necrosis, calcification and obviously enhancement at the solid part. 2 cases showed as oval soft lump with even density, moderate strengthening located before the abdominal aorta. Paroxysmal hypertension occurred in 3 cases and didn't in 2 cases. Hypertension happened in 1 case during the operation because of stimulation. Blood pressure appeared in 1 case during and after operation. Blood and urinary catecholamine increased significantly in 4 cases. Conclusion: Ectopic pheochromocytoma mainly located surround the abdominal aorta with diverse CT performance. It is helpful for diagnosing when finding a lesion locates at the specified sites combined with typical clinical presentation. CT can not only depict small tumor, but also can show the relationship with surrounding structure, and it provides important information for the operation and prognosis. (authors)

  13. Analyser-based phase contrast image reconstruction using geometrical optics

    International Nuclear Information System (INIS)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-01-01

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 μm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser

  14. Phase-contrast x-ray computed tomography for observing biological specimens and organic materials

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Itai, Yuji

    1995-02-01

    A novel three-dimensional x-ray imaging method has been developed by combining a phase-contrast x-ray imaging technique with x-ray computed tomography. This phase-contrast x-ray computed tomography (PCX-CT) provides sectional images of organic specimens that would produce absorption-contrast x-ray CT images with little contrast. Comparing PCX-CT images of rat cerebellum and cancerous rabbit liver specimens with corresponding absorption-contrast CT images shows that PCX-CT is much more sensitive to the internal structure of organic specimens.

  15. Accuracy of the abdominal examination for identifying children with blunt intra-abdominal injuries.

    Science.gov (United States)

    Adelgais, Kathleen M; Kuppermann, Nathan; Kooistra, Joshua; Garcia, Madelyn; Monroe, David J; Mahajan, Prashant; Menaker, Jay; Ehrlich, Peter; Atabaki, Shireen; Page, Kent; Kwok, Maria; Holmes, James F

    2014-12-01

    To determine the accuracy of complaints of abdominal pain and findings of abdominal tenderness for identifying children with intra-abdominal injury (IAI) stratified by Glasgow Coma Scale (GCS) score. This was a prospective, multicenter observational study of children with blunt torso trauma and a GCS score ≥13. We calculated the sensitivity of abdominal findings for IAI with 95% CI stratified by GCS score. We examined the association of isolated abdominal pain or tenderness with IAI and that undergoing acute intervention (therapeutic laparotomy, angiographic embolization, blood transfusion, or ≥2 nights of intravenous fluid therapy). Among the 12 044 patients evaluated, 11 277 (94%) had a GCS score of ≥13 and were included in this analysis. Sensitivity of abdominal pain for IAI was 79% (95% CI, 76%-83%) for patients with a GCS score of 15, 51% (95% CI, 37%-65%) for patients with a GCS score of 14, and 32% (95% CI, 14%-55%) for patients with a GCS score of 13. Sensitivity of abdominal tenderness for IAI also decreased with decreasing GCS score: 79% (95% CI, 75%-82%) for a GCS score of 15, 57% (95% CI, 42%-70%) for a GCS score of 14, and 37% (95% CI, 19%-58%) for a GCS score of 13. Among patients with isolated abdominal pain and/or tenderness, the rate of IAI was 8% (95% CI, 6%-9%) and the rate of IAI undergoing acute intervention was 1% (95% CI, 1%-2%). The sensitivity of abdominal findings for IAI decreases as GCS score decreases. Although abdominal computed tomography is not mandatory, the risk of IAI is sufficiently high that diagnostic evaluation is warranted in children with isolated abdominal pain or tenderness. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  17. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... abdominal conditions in babies, such as vomiting or blood in stool. For some conditions, including but not limited to some liver, kidney, pancreatic, uterine or ... Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  19. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular...... simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50-100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic...... pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons...

  20. Criteria for choice and use of contrast media in intra-arterial D.S.A

    International Nuclear Information System (INIS)

    Dalla-Palma, L.; Stacul, F.; Pozzi-Mucelli, R.

    1985-01-01

    The authors investigated the optimal characteristics of contrast media for use in intra-arterial DSA. 209 injections in 108 patients were evaluated, most of them in the abdominal and peripheral regions. In order to decrease contrast media osmolarity and obtain an adequate mixing with blood, contrast media with low iodine concentration were injected using the same volumes and flow rates of conventional arteriography. Good results were obtained with ionic contrast media, 100 and 150 mgI/ml. depending on the area investigated. The low concentrations allowed the use of ionic agents with an osmolarity very close to that of the non ionic contrast media: the pain has been eliminated and the heat sensation reduced. Furthermore the comparison with the cost of nonionic agents shows a great saving. (orig.)

  1. Analyser-based phase contrast image reconstruction using geometrical optics.

    Science.gov (United States)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-07-21

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.

  2. WE-FG-207B-01: BEST IN PHYSICS (IMAGING): Abdominal CT with Three K-Edge Contrast Materials Using a Whole-Body Photon-Counting Scanner: Initial Results of a Large Animal Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Lakshmanan, M; Symons, R; Cork, T; Davies-Venn, C; Rice, K; Malayeri, A; Sandfort, V; Bluemke, D; Pourmorteza, A [National Institutes of Health Clinical Center, Bethesda, MD (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of in vivo three-material decomposition techniques using photon-counting CT (PCCT) with possible advantage of resolving arterial and venous flow of an organ simultaneously. Methods: Abdominal PCCT scans were acquired using a prototype whole-body PCCT with four energy thresholds (25/50/75/90keV) in a canine. Bismuth subsalicylate (60 mg) was administered orally one day prior to scanning. Immediately prior to CT scan, gadoteric acid (60 ml, Dotarem, Guerbet) was intravenously injected, followed in ten minutes by a 20mL injection of iodinated contrast (iopamidol 370 mg/mL, Bracco). Scans were acquired every ∼20 seconds, starting from the time of iodine injection. Linear material decomposition was performed using the least mean squares method to create concentration maps of iodine, gadolinium, and bismuth. The method was calibrated to vials with known concentrations of materials placed next to the animal. The accuracy of this method was tested on vials with known concentrations. Results: The material decomposition algorithm’s accuracy was confirmed to be within ±4mM in the test vials. In the animal, we could estimate the concentration of gadolinium in delayed-enhanced phase (10 minutes post-injection) in the abdomen. We could follow the wash-in and wash-out of iodine in arterial, venous, and excretory flow of the kidneys (20s, 80s, and 120s post-iodine injection) while gadolinium was present in the delayed-enhanced phase. Bismuth, which was used as a contrast agent for the gastro-intestinal tract, was easily differentiable from the other two contrast agents in the small intestine. Conclusion: This study shows the feasibility of using photon-counting CT with four energy thresholds to differentiate three k-edge contrast agents in vivo. This can potentially reduce radiation dose to patients by combining arterial and venous phases into a single acquisition.

  3. Slit-scanning differential phase-contrast mammography: first experimental results

    Science.gov (United States)

    Roessl, Ewald; Daerr, Heiner; Koehler, Thomas; Martens, Gerhard; van Stevendaal, Udo

    2014-03-01

    The demands for a large field-of-view (FOV) and the stringent requirements for a stable acquisition geometry rank among the major obstacles for the translation of grating-based, differential phase-contrast techniques from the laboratory to clinical applications. While for state-of-the-art Full-Field-Digital Mammography (FFDM) FOVs of 24 cm x 30 cm are common practice, the specifications for mechanical stability are naturally derived from the detector pixel size which ranges between 50 and 100 μm. However, in grating-based, phasecontrast imaging, the relative placement of the gratings in the interferometer must be guaranteed to within micro-meter precision. In this work we report on first experimental results on a phase-contrast x-ray imaging system based on the Philips MicroDose L30 mammography unit. With the proposed approach we achieve a FOV of about 65 mm x 175 mm by the use of the slit-scanning technique. The demand for mechanical stability on a micrometer scale was relaxed by the specific interferometer design, i.e., a rigid, actuator-free mount of the phase-grating G1 with respect to the analyzer-grating G2 onto a common steel frame. The image acquisition and formation processes are described and first phase-contrast images of a test object are presented. A brief discussion of the shortcomings of the current approach is given, including the level of remaining image artifacts and the relatively inefficient usage of the total available x-ray source output.

  4. Parameters of Blood Flow in Great Arteries in Hypertensive ISIAH Rats with Stress-Dependent Arterial Hypertension.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel', A L

    2016-08-01

    Magnetic resonance angiography was used to examine blood flow in great arteries of hypertensive ISIAH and normotensive Wistar rats. In hypertensive ISIAH rats, increased vascular resistance in the basin of the abdominal aorta and renal arteries as well as reduced fraction of total renal blood flow were found. In contrast, blood flow through both carotid arteries in ISIAH rats was enhanced, which in suggests more intensive blood supply to brain regulatory centers providing enhanced stress reactivity of these rats characterized by stress-dependent arterial hypertension.

  5. Phase-contrast MR assessment of pulmonary venous blood flow in children with surgically repaired pulmonary veins

    International Nuclear Information System (INIS)

    Valsangiacomo, Emanuela R.; Yoo, Shi-Joon; Barrea, Catherine; Smallhorn, Jeffrey F.; Macgowan, Christopher K.; Coles, John G.

    2003-01-01

    Pulmonary venous (PV) obstruction may complicate surgical repair of PV abnormalities. By combining phase-contrast cine (PC) imaging and contrast-enhanced angiography, magnetic resonance (MR) imaging can provide physiological information complementing anatomical diagnosis. To compare the PV flow pattern observed after surgical repair of PV abnormalities with normal PV flow pattern and to investigate the changes occurring in the presence of PV stenosis by using PC MR in children. By using PC MR, PV flow was evaluated in 14 patients (3 months-14 years) who underwent surgical repair for PV abnormalities. Eleven children (8-18 years) were studied as normal controls. Peak flow velocities and patterns were compared among three groups: normal veins (n=23), surgically repaired veins without (n=44) and with stenosis (n=10). Normal and unobstructed pulmonary veins after surgery showed a biphasic or triphasic flow pattern with one or two systolic peaks and a diastolic peak. Unobstructed surgically repaired veins showed decreased peak systolic velocity (P =0.001) and an increased peak diastolic velocity (P=0.005) when compared to normal values. Obstructed veins showed decreased systolic and diastolic velocities when measured upstream from the stenosis. PC MR shows different flow patterns among normal, surgically repaired pulmonary veins with and without stenosis. (orig.)

  6. Patent abdominal subcutaneous veins caused by congenital absence of the inferior vena cava: a case report

    Directory of Open Access Journals (Sweden)

    Lipp Rainer W

    2010-07-01

    Full Text Available Abstract Introduction Patent paraumbilical and abdominal subcutaneous veins are found frequently as collaterals in patients due to portal hypertension mainly in liver cirrhosis. Case presentation For evaluation of portal hypertension in a 72-year-old Caucasian man without liver cirrhosis, magnetic resonance imaging with gadolinium contrast-enhancement was performed and demonstrated a missing inferior vena cava. A blood return from the lower extremities was shown through enlarged collateral veins of the abdominal wall, vena azygos and hemiazygos continuation, and multiple liver veins emptying into the right cardiac atrium. We describe a rare case of abdominal subcutaneous wall veins as collaterals caused by a congenitally absent infrarenal inferior vena cava with preservation of a hypoplastic suprarenal segment. Conclusion Knowledge of these congenital variations can be of clinical importance and it is imperative for the reporting radiologist to identify these anomalies as they can have a significant impact on the clinical management of the patient.

  7. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  8. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  9. Development of phase-contrast imaging technique for material science and medical science applications

    International Nuclear Information System (INIS)

    Kashyap, Y.S.; Roy, Tushar; Sarkar, P.S; Shukla, Mayank; Yadav, P.S; Sinha, Amar; Verma, Vishnu; Ghosh, A.K.

    2007-07-01

    In-line phase contrast imaging technique is an emerging method for study of materials such as carbon fibres, carbon composite materials, polymers etc. These represent the class of materials for which x-ray attenuation cross-section is very small. Similarly, this technique is also well suited for imaging of soft materials such as tissues, distinguishing between tumour and normal tissue. Thus this method promises a far better contrast for low x-ray absorbing substances than the conventional radiography method for material and medical science applications. Though the conventional radiography technique has been carried out for decades, the phase-imaging technique is being demonstrated for the first time within, the country. We have set up an experimental facility for phase contrast imaging using a combination of x-ray CCD detector and a microfocus x-ray source. This facility is dedicated for micro-imaging experiments such as micro-tomography and high resolution phase contrast experiments. In this report, the results of phase contrast imaging using microfocus source and ELETTRA, synchrotron source are discussed. We have also discussed the basic design and heat load calculation for upcoming imaging beamline at Indus-II, RRCAT, Indore. (author)

  10. Consumo de bebida alcoólica e adiposidade abdominal em doadores de sangue Consumo de bebida alcohólica y adiposidad abdominal en donadores de sangre Alcohol consumption and abdominal fat in blood donors

    Directory of Open Access Journals (Sweden)

    Márcia Gonçalves Ferreira

    2008-12-01

    ón lineal múltiple, con los modelos ajustados para la edad, actividad física, tabaquismo y adiposidad total. RESULTADOS: Posterior al ajuste, la circunferencia de la cintura y la relación cintura/cuadril se mantuvieron asociados positivamente al consumo de cerveza (p=0,02 y al total de alcohol consumido (p=0,01 y 0,03, respectivamente. El consumo de aguardiente mostró asociación solamente con la circunferencia de la cintura (p=0,04. CONCLUSIONES: El consumo de alcohol, particularmente de cerveza, se asoció con la localización abdominal de gordura.OBJECTIVE: To evaluate the association between alcohol consumption and abdominal fat. METHODS: Cross-sectional study carried out in a sample of male blood donors (n=1,235, aged 20-59 years, in the city of Cuiabá, Central-West Brazil, between August 1999 and January 2000. Waist circumference and waist-to-hip ratio were indicators of abdominal fat, adjusted for total adiposity. Weight, height, waist and hip circumferences were measured. Alcohol consumption was evaluated using a questionnaire collecting information on type, frequency, and amount of consumption. The association between alcohol consumption and abdominal fat was assessed through multiple linear regression models adjusted for age, physical activity, smoking, and percent of body fat. RESULTS: After adjustment, waist circumference and waist-to-hip ratio were positively associated with beer (p = 0.02 and total alcohol consumption (p=0.01; p=0.03, respectively. Waist circumference was positively associated with spirit consumption (p=0.04. CONCLUSIONS: Alcohol intake, particularly beer, was positively associated to abdominal fat.

  11. Synchrotron Based Phase Contrast Tomography of Hyper cholesteromic Rat Liver

    Directory of Open Access Journals (Sweden)

    Fatima A

    2017-05-01

    Full Text Available X-ray phase contrast imaging technique has been applied for the study of morphological variations in soft tissues. The effect of an antioxidant, α-lipoic acid in reducing hypercholesterolemia in rats is investigated. The experiment was conducted to measure serum lipid profile and diameter of vessels in rat liver, as liver is the most vital organ in hypolipidemic activity studies. Methods: Four groups of male Wistar rats, control (Group I, hyperlipidemic (Group II, positive control (Group III and treated Group IV were studied for serum lipid profile and liver vessels with synchrotron X-ray phase tomography. The Group I rats received chow diet, in Group II rats, administration of 20% butter rich diet induced hyperlipidemia. Group III, treated rats received hypolipidemic drug Atorvastatin and Group IV animals received a potent antioxidant DL-α-Lipoic acid. The excised liver tissue immersed in 10% formalin. X-ray phase contrast tomography was performed for comparison of diameter of liver vessels. Results: Among the four group of animals, the diameter of liver vessels was much larger in hypercholesterolemic rat (Group II. The liver vessel diameter comparison with X-ray phase contrast tomography and the lipid profile shows reduction in serum lipids and lipoproteins by ALA treatment.

  12. Hemodynamic measurement using four-dimensional phase-contrast MRI: Quantification of hemodynamic parameters and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Ho Jin; Lee, Sang Joon [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang (Korea, Republic of); Kim, Guk Bae; Kweon, Ji Hoon; Kim, Young Hak; Lee, Deok Hee; Yang, Dong Hyun; KIm, Nam Kug [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.

  13. Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hojin [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Kim, Guk Bae [Asan Institute of Life Science, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Kweon, Jihoon [Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Lee, Sang Joon [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Kim, Young-Hak [Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Lee, Deok Hee; Yang, Dong Hyun [Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Kim, Namkug [Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of)

    2016-11-01

    Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.

  14. First principles study of the optical contrast in phase change materials

    Energy Technology Data Exchange (ETDEWEB)

    Caravati, S; Parrinello, M [Department of Chemistry and Applied Biosciences, ETH Zurich, USI Campus, Via Giuseppe Buffi 13, 6900 Lugano (Switzerland); Bernasconi, M, E-mail: marco.bernasconi@mater.unimib.i [Dipartimento di Scienza dei Materiali, Universita di Milano-Bicocca, Via R Cozzi 53, I-20125, Milano (Italy)

    2010-08-11

    We study from first principles the optical properties of the phase change materials Ge{sub 2}Sb{sub 2}Te{sub 5} (GST), GeTe and Sb{sub 2}Te{sub 3} in the crystalline phase and in realistic models of the amorphous phase generated by quenching from the melt in ab initio molecular dynamics simulations. The calculations reproduce the strong optical contrast between the crystalline and amorphous phases measured experimentally and exploited in optical data storage. It is demonstrated that the optical contrast is due to a change in the optical matrix elements across the phase change in all the compounds. It is concluded that the reduction of the optical matrix elements in the amorphous phases is due to angular disorder in p-bonding which dominates the amorphous network in agreement with previous proposals (Huang and Robertson 2010 Phys. Rev. B 81 081204) based on calculations on crystalline models.

  15. Effect of ionic and non-ionic contrast media on aggregation of red blood cells in vitro

    International Nuclear Information System (INIS)

    Raininko, R.; Ylinen, S.L.

    1987-01-01

    Fresh human blood without additives, and contrast medium were mixed and examined immediately by light microscopy in a non-flowing state. Sodium meglumine diatrizoate, meglumine diatrizoate, meglumine iodamide, sodium meglumine ioxaglate, iopromide, iopamidol, iohexol, and metrizamide were tested in concentrations of 300 mgI/ml. Physiologic saline and 5% glucose were used as controls. All media were tested in a randomized order with blood samples from 23 volunteers. No aggregation was detected in physiologic saline, and few rouleaux were found in ionic contrast media. Irregular red cell aggregates were found in all low-osmolal contrast media: in 17% of the specimens in ioxaglate, in 52% in metrizamide, and in 78 to 100% in other non-ionic media. Irregular aggregates were seen in all specimens with glucose. It remains to be domonstrated whether or not the irregular aggregation of human red cells in non-ionic contrast media has clinical significance. Iohexol was also tested with blood samples from several laboratory animals, but in nearly every case no aggregates were found. Results of animal experiments or tests with animal blood seem to be poorly applicable to man. (orig.)

  16. Abdominal imaging in AIDS patients

    International Nuclear Information System (INIS)

    Zhao Dawei; Wang Wei; Yuan Chunwang; Jia Cuiyu; Zhao Xuan; Zhang Tong; Ma Daqing

    2007-01-01

    Objective: To evaluate abdominal imaging in AIDS. Methods: The imaging examinations (including US, CT and MR) of 6 patients with AIDS associated abdominal foci were analysed retrospectively. All the cases were performed US, and CT scan, of which 4 performed enhanced CT scan and 1 with MR. Results: Abdominal tuberculosis were found in 4 patients, including abdominal lymph nodes tuberculosis (3 cases) and pancreatic tuberculosis (1 case). The imaging of lymph nodes tuberculosis typically showed enlarged peripheral tim enhancement with central low-attenuation on contrast-enhanced CT. Pancreatic tuberculosis demonstrated low-attenuation area in pancreatic head and slightly peripheral enhancement. Disseminated Kaposi's sarcoma was seen in 1 case: CT and MRI scan demonstrated tumour infiltrated along hepatic portal vein and bronchovascular bundles. Pelvic tumor was observed in 1 case: CT scan showed large mass with thick and irregular wall and central low attenuation liquefacient necrotic area in the pelvic cavity. Conclusion: The imaging findings of AIDS with abdominal foci is extraordinarily helpful to the diagnosis of such disease. Tissue biopsy is needed to confirm the diagnosis. (authors)

  17. Dehydration and fluid volume kinetics before major open abdominal surgery.

    Science.gov (United States)

    Hahn, R G; Bahlmann, H; Nilsson, L

    2014-11-01

    Assessment of dehydration in the preoperative setting is of potential clinical value. The present study uses urine analysis and plasma volume kinetics, which have both been validated against induced changes in body water in volunteers, to study the incidence and severity of dehydration before open abdominal surgery begins. Thirty patients (mean age 64 years) had their urine analysed before major elective open abdominal surgery for colour, specific weight, osmolality and creatinine. The results were scored and the mean taken to represent a 'dehydration index'. Thereafter, the patients received an infusion of 5 ml/kg of Ringer's acetate intravenously for over 15 min. Blood was sampled for 70 min and the blood haemoglobin concentration used to estimate the plasma volume kinetics. Distribution of fluid occurred more slowly (P dehydrated as compared with euhydrated patients. The dehydration index indicated that the fluid deficit in these patients corresponded to 2.5% of the body weight, whereas the deficit in the others was 1%. In contrast, the 11 patients who later developed postoperative nausea and vomiting had a very short elimination half-life, only 9 min (median, P dehydration before major surgery was modest as evidenced both by urine sampling and volume kinetic analysis. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Stable and simple quantitative phase-contrast imaging by Fresnel biprism

    Science.gov (United States)

    Ebrahimi, Samira; Dashtdar, Masoomeh; Sánchez-Ortiga, Emilio; Martínez-Corral, Manuel; Javidi, Bahram

    2018-03-01

    Digital holographic (DH) microscopy has grown into a powerful nondestructive technique for the real-time study of living cells including dynamic membrane changes and cell fluctuations in nanometer and sub-nanometer scales. The conventional DH microscopy configurations require a separately generated coherent reference wave that results in a low phase stability and a necessity to precisely adjust the intensity ratio between two overlapping beams. In this work, we present a compact, simple, and very stable common-path DH microscope, employing a self-referencing configuration. The microscope is implemented by a diode laser as the source and a Fresnel biprism for splitting and recombining the beams simultaneously. In the overlapping area, linear interference fringes with high contrast are produced. The frequency of the interference pattern could be easily adjusted by displacement of the biprism along the optical axis without a decrease in fringe contrast. To evaluate the validity of the method, the spatial noise and temporal stability of the setup are compared with the common off-axis DH microscope based on a Mach-Zehnder interferometer. It is shown that the proposed technique has low mechanical noise as well as superb temporal stability with sub-nanometer precision without any external vibration isolation. The higher temporal stability improves the capabilities of the microscope for studying micro-object fluctuations, particularly in the case of biological specimens. Experimental results are presented using red blood cells and silica microspheres to demonstrate the system performance.

  19. Efeitos da Histerectomia Total Abdominal sobre o Fluxo Sangüíneo Ovariano Effect of Total Abdominal Hysterectomy on Ovarian Blood Supply

    Directory of Open Access Journals (Sweden)

    Eliana Aguiar Petri Nahás

    2002-06-01

    Full Text Available Objetivo: avaliar os efeitos da histerectomia total abdominal (HTA sobre o fluxo sangüíneo ovariano, em mulheres no menacme, por meio da dopplervelocimetria e ultra-sonografia transvaginal. Métodos: estudo prospectivo no qual foram incluídas 61 mulheres, com idade igual ou inferior a 40 anos. As pacientes foram divididas em dois grupos: G1, com 31 pacientes submetidas à HTA, e G2, com 30 mulheres normais não submetidas à cirurgia. Somente foram incluídas pacientes eumenorréicas, ovulatórias, não-obesas ou fumantes, sem cirurgias ou doenças ovarianas prévias. Avaliou-se o fluxo sangüíneo das artérias ovarianas, inicialmente e aos 6 e 12 meses, pelo índice de pulsatilidade (IP na dopplervelocimetria, e o volume ovariano pela ultra-sonografia transvaginal (US. Para análise estatística empregou-se teste t pareado, análise de perfil, teste de Friedman e teste de Mann-Whitney. Resultados: na comparação estatística inicial os grupos foram homogêneos quanto às características epidemiológicas e quanto aos demais parâmetros avaliados neste estudo. Nas pacientes submetidas à histerectomia, observaram-se aos 6 e 12 meses aumento do volume ovariano ao US e diminuição do IP avaliado pela dopplervelocimetria (pPurpose: to evaluate the effect of total abdominal hysterectomy on ovarian blood supply in women in reproductive age, using transvaginal color Doppler. Methods: a prospective study was carried out on 61 40-year-old or younger women. They were divided into two groups: G1, 31 patients submitted to hysterectomy, and G2, 30 normal women. Criteria of inclusion: normal ovarian function at baseline, normal body weight, without expasure to tobacco, no history of laparotomy or ovarian pathology. The pulsatility index (PI of ovarian arteries determined by Doppler and the transvaginal ultrasonographic measurement of the ovarian volume were performed at three moments: baseline, 6 and 12 months. Results: at baseline the groups were

  20. A phase contrast interferometer on DIII-D

    International Nuclear Information System (INIS)

    Coda, S.; Porkolab, M.; Carlstrom, T.N.

    1992-04-01

    A novel imaging diagnostic has recently become operational on the DIII-D tokamak for the study of density fluctuations at the outer edge of the plasma. The phase contrast imaging approach overcomes the limitations of conventional scattering techniques in the spectral range of interest for transport-related phenomena, by allowing detection of long wavelength modes (up to 7.6 cm) with excellent spatial resolution (5 mm) in the radial direction. Additional motivation for the diagnostic is provided by wave-plasma interactions during heating and current drive experiments in the Ion Cyclotron range of frequencies. Density perturbations of 4 x 10 7 cm -3 with a 1 MHz bandwidth can be resolved. The diagnostic employs a 7.6 cm diameter CO 2 laser beam launched vertically across the plasma edge. An image of the plasma is then created on a 16-element detector array: the detector signals are directly proportional to the density fluctuations integrated along each chord. Wavelengths and correlation lengths can be inferred from the spatial mapping. The phase contrast method and its application to DIII-D are described and tests and first plasma data are presented

  1. Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals

    International Nuclear Information System (INIS)

    Hoennicke, M. G.; Cusatis, C.

    2007-01-01

    An analyzer-based x-ray phase-contrast microscopy (ABM) setup combining a standard analyzer-based x-ray phase-contrast imaging (ABI) setup [nondispersive 4-crystal setup (Bonse-Hart setup)] and diffraction by asymmetrically cut crystals is presented here. An attenuation-contrast microscopy setup with conventional x-ray source and asymmetrically cut crystals is first analyzed. Edge-enhanced effects attributed to phase jumps or refraction/total external reflection on the fiber borders were detected. However, the long exposure times and the possibility to achieve high contrast microscopies by using extremely low attenuation-contrast samples motivated us to assemble the ABM setup using a synchrotron source. This setup was found to be useful for low contrast attenuation samples due to the low exposure time, high contrast, and spatial resolution found. Moreover, thanks to the combination with the nondispersive ABI setup, the diffraction-enhanced x-ray imaging algorithm could be applied

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  3. Intra-abdominal fat accumulation is a hypertension risk factor in young adulthood: A cross-sectional study.

    Science.gov (United States)

    Takeoka, Atsushi; Tayama, Jun; Yamasaki, Hironori; Kobayashi, Masakazu; Ogawa, Sayaka; Saigo, Tatsuo; Kawano, Hiroaki; Abiru, Norio; Hayashida, Masaki; Maeda, Takahiro; Shirabe, Susumu

    2016-11-01

    Accumulation of intra-abdominal fat is related to hypertension. Despite this, a relationship between hypertension and intra-abdominal fat in young adulthood is not clear. In this study, we verify whether intra-abdominal fat accumulation increases a hypertension risk in young adult subjects.In a cross-sectional study, intra-abdominal fat area was measured using a dual bioelectrical impedance analysis instrument in 697 university students (20.3 ± 0.7 years, 425 men). Blood pressure and anthropometric factors were measured. Lifestyle variables including smoking, drinking, physical activity, and eating behavior were assessed with questionnaire. High blood pressure risk (systolic blood pressure ≥130 mm Hg and/or diastolic blood pressure ≥85 mm Hg) with increasing intra-abdominal fat area was evaluated.Participants were divided into 5 groups according to their intra-abdominal fat area (≤24.9, 25-49.9, 50-74.9, 75-99.9, and ≥100 cm). As compared with the values of the smallest intra-abdominal fat area group, the crude and lifestyle-adjusted odds ratios (ORs) were elevated in larger intra-abdominal fat area groups [OR 1.31, 95% confidence interval (CI) 0.66-2.80; OR 3.38, 95% CI 1.60-7.57; OR 7.71, 95% CI 2.75-22.22; OR 18.74, 95% CI 3.93-105.64, respectively). The risk increase was observed only in men.Intra-abdominal fat accumulation is related to high blood pressure in men around 20 years of age. These results indicate the importance of evaluation and reduction of intra-abdominal fat to prevent hypertension.

  4. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    International Nuclear Information System (INIS)

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2015-01-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization. (fast track communication)

  5. Combined mixed approach algorithm for in-line phase-contrast x-ray imaging

    International Nuclear Information System (INIS)

    De Caro, Liberato; Scattarella, Francesco; Giannini, Cinzia; Tangaro, Sabina; Rigon, Luigi; Longo, Renata; Bellotti, Roberto

    2010-01-01

    Purpose: In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an imaging modality thought to enhance the total contrast of the images through the phase shift introduced by the object (human body part); PRI is a mathematical technique to extract the quantitative phase-shift map from PCI. A new phase-retrieval algorithm for the in-line phase-contrast x-ray imaging is here proposed. Methods: The proposed algorithm is based on a mixed transfer-function and transport-of-intensity approach (MA) and it requires, at most, an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy in the initial estimate determines the convergence speed of the algorithm. The proposed algorithm retrieves both the object phase and its complex conjugate in a combined MA (CMA). Results: Although slightly less computationally effective with respect to other mixed-approach algorithms, as two phases have to be retrieved, the results obtained by the CMA on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The authors have also tested the CMA on noisy experimental phase-contrast data obtained by a suitable weakly absorbing sample consisting of a grid of submillimetric nylon fibers as well as on a strongly absorbing object made of a 0.03 mm thick lead x-ray resolution star pattern. The CMA has shown a good efficiency in recovering phase information, also in presence of noisy data, characterized by peak-to-peak signal-to-noise ratios down to a few dBs, showing the possibility to enhance with phase radiography the signal-to-noise ratio for features in the submillimetric scale with respect to the attenuation

  6. Regularized iterative integration combined with non-linear diffusion filtering for phase-contrast x-ray computed tomography.

    Science.gov (United States)

    Burger, Karin; Koehler, Thomas; Chabior, Michael; Allner, Sebastian; Marschner, Mathias; Fehringer, Andreas; Willner, Marian; Pfeiffer, Franz; Noël, Peter

    2014-12-29

    Phase-contrast x-ray computed tomography has a high potential to become clinically implemented because of its complementarity to conventional absorption-contrast.In this study, we investigate noise-reducing but resolution-preserving analytical reconstruction methods to improve differential phase-contrast imaging. We apply the non-linear Perona-Malik filter on phase-contrast data prior or post filtered backprojected reconstruction. Secondly, the Hilbert kernel is replaced by regularized iterative integration followed by ramp filtered backprojection as used for absorption-contrast imaging. Combining the Perona-Malik filter with this integration algorithm allows to successfully reveal relevant sample features, quantitatively confirmed by significantly increased structural similarity indices and contrast-to-noise ratios. With this concept, phase-contrast imaging can be performed at considerably lower dose.

  7. Changes in Hepatic Blood Flow and Liver Function during Closed Abdominal Hyperthermic Intraperitoneal Chemotherapy following Cytoreduction Surgery

    Directory of Open Access Journals (Sweden)

    Stéphanie Dupont

    2018-01-01

    Full Text Available Background. The increase in intra-abdominal pressure (IAP during closed abdominal hyperthermic intraperitoneal chemotherapy (HIPEC leads to major haemodynamic changes and potential organ dysfunction. We investigated these effects on hepatic blood flow (HBF and liver function in patients undergoing HIPEC following cytoreductive surgery and fluid management guided by dynamic preload indices. Methods. In this prospective observational clinical study including 15 consecutive patients, we evaluated HBF by transesophageal echocardiography and liver function by determination of the indocyanine green plasma disappearance rate (ICG-PDR. Friedman’s two-way analysis of variance by ranks and Wilcoxon signed-rank test were performed for statistical analysis. Results. During HIPEC, HBF was markedly reduced, resulting in the loss of any pulsatile Doppler flow signal in all but one patient. The ICG-PDR, expressed as median (interquartile 25–75, decreased from 23 (20–30 %/min to 18 (12.5–19 %/min (p<0.001. Despite a generous crystalloid infusion rate (27 (22–35 ml/kg/h, cardiac index decreased during the increased IAP period, inferior vena cava diameter decreased, stroke volume variation and pulse pressure variation increased, lung compliance dropped, and there was an augmentation in plateau pressure. All changes were significant (p<0.001 and reversed to baseline values post HIPEC. Conclusion. Despite optimizing intravenous fluids during closed abdominal HIPEC, we observed a marked decrease in HBF and liver function. Both effects were transient and limited to the period of HIPEC but could influence the choice between closed or open abdominal cavity procedure for HIPEC and should be considered in similar clinical situations of increased IAP.

  8. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  9. Comparison of post contrast CT urography phases in bladder cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders [Uppsala University Hospital, Department of Surgical Sciences, Section of Radiology, Uppsala (Sweden); Brekkan, Einar [Uppsala University Hospital, Department of Surgical Sciences, Section of Urology, Uppsala (Sweden); Wernroth, Lisa [Uppsala University Hospital, Uppsala Clinical Research Center, Uppsala (Sweden)

    2016-02-15

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  10. Comparison of post contrast CT urography phases in bladder cancer detection

    International Nuclear Information System (INIS)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders; Brekkan, Einar; Wernroth, Lisa

    2016-01-01

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  11. The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry

    International Nuclear Information System (INIS)

    Yang Yi; Tang Xiangyang

    2012-01-01

    Purpose: The x-ray differential phase contrast imaging implemented with the Talbot interferometry has recently been reported to be capable of providing tomographic images corresponding to attenuation-contrast, phase-contrast, and dark-field contrast, simultaneously, from a single set of projection data. The authors believe that, along with small-angle x-ray scattering, the second-order phase derivative Φ ″ s (x) plays a role in the generation of dark-field contrast. In this paper, the authors derive the analytic formulae to characterize the contribution made by the second-order phase derivative to the dark-field contrast (namely, second-order differential phase contrast) and validate them via computer simulation study. By proposing a practical retrieval method, the authors investigate the potential of second-order differential phase contrast imaging for extensive applications. Methods: The theoretical derivation starts at assuming that the refractive index decrement of an object can be decomposed into δ=δ s +δ f , where δ f corresponds to the object's fine structures and manifests itself in the dark-field contrast via small-angle scattering. Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the contribution made by δ s , which corresponds to the object's smooth structures, to the dark-field contrast are derived. Through computer simulation with specially designed numerical phantoms, an x-ray differential phase contrast imaging system implemented with the Talbot interferometry is utilized to evaluate and validate the derived formulae. The same imaging system is also utilized to evaluate and verify the capability of the proposed method to retrieve the second-order differential phase contrast for imaging, as well as its robustness over the dimension of detector cell and the number of steps in grating shifting. Results: Both analytic formulae and computer simulations show that, in addition to small-angle scattering, the

  12. Clinical implementation of x-ray phase-contrast imaging: Theoretical foundations and design considerations

    International Nuclear Information System (INIS)

    Wu Xizeng; Liu Hong

    2003-01-01

    Theoretical foundation and design considerations of a clinical feasible x-ray phase contrast imaging technique were presented in this paper. Different from the analysis of imaging phase object with weak absorption in literature, we proposed a new formalism for in-line phase-contrast imaging to analyze the effects of four clinically important factors on the phase contrast. These are the body parts attenuation, the spatial coherence of spherical waves from a finite-size focal spot, and polychromatic x-ray and radiation doses to patients for clinical applications. The theory presented in this paper can be applied widely in diagnostic x-ray imaging procedures. As an example, computer simulations were conducted and optimal design parameters were derived for clinical mammography. The results of phantom experiments were also presented which validated the theoretical analysis and computer simulations

  13. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    International Nuclear Information System (INIS)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge

    2014-01-01

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  14. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge [Dept. of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou (China)

    2014-08-15

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  15. Arterio-venous anastomoses in mice affect perfusion measurements with dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Gabra, Peter; Lee, Ting-Yim; Shen, Gang; Xuan, Jim

    2010-01-01

    Accurate measurement of perfusion with dynamic contrast enhanced CT requires an arterial input curve (AIC) uncontaminated by venous sources. Arterio-venous anastomoses (AVAs) are sources of contamination if contrast is injected intravenously. We seek to identify AVAs in mice and associated errors in perfusion measurements. Six transgenic mice with spontaneous prostate tumor were scanned with a micro-CT scanner (GE Healthcare (GE)) using a high resolution anatomical and a lower resolution perfusion protocol. For the anatomical protocol, a CT scan was performed during injection of an iodinated contrast agent (Hypaque) into a tail vein. Images covering the thoracic, abdominal and pelvic regions at an isotropic resolution of 175 µm were reconstructed and rendered in 3D to show the arterial and venous tree (Advantage Window, GE). For the perfusion protocol, each mouse was continuously scanned for 40 s and the contrast agent (Hypaque) was injected via a tail vein 5 s into scanning. Tumor images were reconstructed every second. Tumor blood flow (BF) and volume (BV) maps were calculated with CT perfusion software (GE) using AIC measured either from abdominal aorta (AA) or tail (caudal) artery (TA). In all mice, there was an AVA from the bifurcation of the inferior vena cava to the tail artery shunting venous blood and portion of the contrast agent injected into the tail vein into the TA. Contrast arrival time at the TA preceded that at the AA by 3.3 ± 0.5 s (P < 0.05). Mean tumor BV and BF values calculated with AA versus TA were 10.0 ± 1.8 versus 4.8 ± 2.1 ml (100 g) −1 (P < 0.05) and 108.8 ± 26.5 versus 33.0 ± 8.5 ml min −1 100 g −1 (P < 0.05), respectively. AVA in the murine pelvic region can result in inaccurate and more variable measurements of pelvic organ/tissue perfusion when the tail artery is used as the AIC

  16. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    International Nuclear Information System (INIS)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  17. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    Science.gov (United States)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  18. Perforated peptic ulcer associated with abdominal compartment syndrome.

    Science.gov (United States)

    Lynn, Jiun-Jen; Weng, Yi-Ming; Weng, Chia-Sui

    2008-11-01

    Abdominal compartment syndrome (ACS) is defined as an increased intra-abdominal pressure with adverse physiologic consequences. Abdominal compartment syndrome caused by perforated peptic ulcer is rare owing to early diagnosis and management. Delayed recognition of perforated peptic ulcer with pneumoperitoneum, bowel distension, and decreased abdominal wall compliance can make up a vicious circle and lead to ACS. We report a case of perforated peptic ulcer associated with ACS. A 74-year-old man with old stroke and dementia history was found to have distended abdomen, edema of bilateral legs, and cyanosis. Laboratory tests revealed deterioration of liver and kidney function. Abdominal compartment syndrome was suspected, and image study was arranged to find the cause. The study showed pneumoperitoneum, contrast stasis in heart with decreased caliber of vessels below the abdominal aortic level, and diffuse lymphedema at the abdominal walls. Emergent laparotomy was performed. Perforated peptic ulcer was noted and the gastrorrhaphy was done. The symptoms, and liver and kidney function improved right after emergent operation.

  19. Non-destructive characterisation of polymers and Al-alloys by polychromatic cone-beam phase contrast tomography

    International Nuclear Information System (INIS)

    Kastner, Johann; Plank, Bernhard; Requena, Guillermo

    2012-01-01

    X-ray computed tomography (XCT) has become a very important tool for the non-destructive characterisation of materials. Continuous improvements in the quality and performance of X-ray tubes and detectors have led to cone-beam XCT systems that can now achieve spatial resolutions down to 1 μm and even below. Since not only the amplitude but also the phase of an X-ray beam is altered while passing through an object, phase contrast effects can occur even for polychromatic sources when the spatial coherence due to a small focal spot size is high enough. This can lead to significant improvements over conventional attenuation-based X-ray computed tomography. Phase contrast can increase by edge enhancement the visibility of small structures and of features which are only slightly different in attenuation. We report on the possibilities of polychromatic cone-beam phase contrast tomography for non-destructive characterisation of materials. A carbon fibre-reinforced polymer and the Al-alloys AlMg5Si7 and AlSi18 were investigated with high resolution cone-beam X-ray computed tomography with a polychromatic tube source. Under certain conditions strong phase contrast resulting in an upward and downward overshooting of the grey values across edges was observed. The phase effects are much stronger for the polymer than for the Al-alloys. The influence on the phase contrast of the parameters, including source-detector distance, focal spot size and tube acceleration voltage is presented. Maximum phase contrast was observed for a maximum distance between the source and the detector, for a low voltage and a minimum focal spot size at the X-ray source. The detectability of the different phases is improved by the edge enhancement and the resulting improvement of sharpness. Thus, a better segmentation of the carbon fibres in the fibre-reinforced polymer and of the Mg 2 Si-phase in the AlMg5Si7-alloy is achieved. Primary and eutectic Si cannot be detected by attenuation-based X

  20. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco

    2012-01-01

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  1. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Laboratory for Micro and Nanotechnology, Paul Scherrer Institut, 5232 Villigen (Switzerland); Philips Technologie GmbH, Roentgenstrasse 24, 22335 Hamburg (Germany); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Radiology, Kantonsspital Baden, 5404 Baden (Switzerland); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Gynecology and Obstetrics, Interdisciplinary Breast Center Baden, Kantonsspital Baden, 5404 Baden (Switzerland); Swiss Light Source, Paul Scherrer Institut, 5232 Villigen, Switzerland and Institute for Biomedical Engineering, University and ETH Zuerich, 8092 Zuerich (Switzerland)

    2012-07-31

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  2. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  3. Estimation of visibility of phase contrast with extraction voltages for field emission gun electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Xing, E-mail: xmeng101@gmail.com

    2017-02-15

    Estimation was made for visibility of phase contrast with varying extraction voltages. The resulting decay rates of visibility show that images with low image contrast from cryo EM will be seriously impacted with high extraction voltages. - Highlights: • Cryo EM • Phase contrast • Extraction votage.

  4. Plasma osmotic changes during major abdominal surgery.

    Science.gov (United States)

    Malone, R A; McLeavey, C A; Arens, J F

    1977-12-01

    Fluid balance across the capillary membrane is maintained normally by a balance of hydrostatic and colloid osmotic pressures (COP). In 12 patients having major intra-abdominal procedures, the COP was followed during the operative and immediate postoperative periods. The patients' intraoperative fluid management consisted of replacing shed blood with blood and following Shires' concept of crystalloid replacement. Significant decreases in COP to approximately two thirds of the initial value occurred in patients having intra-abdominal procedures versus only a 10 percent decrease in those having peripheral procedures (greater than .001). As a result of this decrease in COP, the balance between hydrostatic and colloid osmotic pressures is lost and risk of pulmonary intersitial edema is increased.

  5. Low dose reconstruction algorithm for differential phase contrast imaging.

    Science.gov (United States)

    Wang, Zhentian; Huang, Zhifeng; Zhang, Li; Chen, Zhiqiang; Kang, Kejun; Yin, Hongxia; Wang, Zhenchang; Marco, Stampanoni

    2011-01-01

    Differential phase contrast imaging computed tomography (DPCI-CT) is a novel x-ray inspection method to reconstruct the distribution of refraction index rather than the attenuation coefficient in weakly absorbing samples. In this paper, we propose an iterative reconstruction algorithm for DPCI-CT which benefits from the new compressed sensing theory. We first realize a differential algebraic reconstruction technique (DART) by discretizing the projection process of the differential phase contrast imaging into a linear partial derivative matrix. In this way the compressed sensing reconstruction problem of DPCI reconstruction can be transformed to a resolved problem in the transmission imaging CT. Our algorithm has the potential to reconstruct the refraction index distribution of the sample from highly undersampled projection data. Thus it can significantly reduce the dose and inspection time. The proposed algorithm has been validated by numerical simulations and actual experiments.

  6. Radiologic findings of abdominal wall endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Wook [Inje Univ. Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2003-12-01

    To evaluate the imaging findings of abdominal wall endometriosis. In seven of 17 patients with surgically proven endometriosis of the abdominal wall, we retrospectively reviewed the findings of radiologic studies such as abdominal US (n=3), CT (n=4), and MRI (n=1). One patient under went more than one type of imaging, apparently. The surgical history of the seven, and their symptoms and preoperative diagnosis were reviewed, and the size, location, margin and nature of the mass, and the contrast enhancement patterns observed at radiologic studies, were assessed. The chief symptoms were palpable abdominal wall mass (n=5) and lower abdominal pain (n=2) around a surgical scar. Previous surgery included cesarean section (n=5), cesarean section with oophorectomy (n=1) and appendectomy (n=1). Masses were located in the subcutaneous fat layer (n=5) or rectus abdominis muscle (n=2), and their maximum diameter was 2.6 cm. Imaging findings, which correlated closely with the pathologic findings, included a well (n=5) or poorly marginated (n=2) solid mass, with a focal cystic area apparent in two cases. Although imaging findings of abdominal wall endometriosis may not be specific for diagnosis, the presence of a solid abdominal mass in female patients of reproductive age with a history of surgery is a diagnostic pointer.

  7. Radiologic findings of abdominal wall endometriosis

    International Nuclear Information System (INIS)

    Seo, Jung Wook

    2003-01-01

    To evaluate the imaging findings of abdominal wall endometriosis. In seven of 17 patients with surgically proven endometriosis of the abdominal wall, we retrospectively reviewed the findings of radiologic studies such as abdominal US (n=3), CT (n=4), and MRI (n=1). One patient under went more than one type of imaging, apparently. The surgical history of the seven, and their symptoms and preoperative diagnosis were reviewed, and the size, location, margin and nature of the mass, and the contrast enhancement patterns observed at radiologic studies, were assessed. The chief symptoms were palpable abdominal wall mass (n=5) and lower abdominal pain (n=2) around a surgical scar. Previous surgery included cesarean section (n=5), cesarean section with oophorectomy (n=1) and appendectomy (n=1). Masses were located in the subcutaneous fat layer (n=5) or rectus abdominis muscle (n=2), and their maximum diameter was 2.6 cm. Imaging findings, which correlated closely with the pathologic findings, included a well (n=5) or poorly marginated (n=2) solid mass, with a focal cystic area apparent in two cases. Although imaging findings of abdominal wall endometriosis may not be specific for diagnosis, the presence of a solid abdominal mass in female patients of reproductive age with a history of surgery is a diagnostic pointer

  8. [Clinical Approach to Abdominal Pain as Functional Origin].

    Science.gov (United States)

    Ryu, Han Seung; Choi, Suck Chei

    2018-02-25

    Abdominal pain is a common symptom that patients refer to a hospital. Organic causes should be differentiated in patients with abdominal pain and treatment should be administered in accordance with the causes. A meticulous history taking and physical examination are highly useful in making a diagnosis, and blood tests, imaging modalities, and endoscopy are useful for confirming diagnosis. However, in many cases, patients have functional disorders with no obvious abnormal findings obtained even if many diagnostic tests are performed. Patients with functional disorders usually complain the vague abdominal pain located in the center and other portions of the abdominal area. Although the most representative disease is irritable bowel syndrome, functional abdominal pain syndrome is currently researched as a new disease entity of functional abdominal pain. As various receptors related to functional abdominal pain have been discovered, drugs associated with those receptors are used to treat the disorders, and additional new drugs are vigorously developed. In addition, medical therapy with pharmacological or non-pharmacological psychiatric treatment is effective for treating functional abdominal pain.

  9. Bladder distension as a cause of abdominal compartment syndrome

    International Nuclear Information System (INIS)

    Yasir, M.; Hoda, M.Q.

    2018-01-01

    Abdominal compartment syndrome (ACS) is increasingly identified in critically ill patient and its harmful effects are well documented. The disparity among the pressure, volume in abdominal cavity and its contents, results in ACS. The actual incidence of ACS is not known. However, it has been observed predominantly in patients with severe blunt and penetrating abdominal trauma, ruptured abdominal aortic aneurysms, retro- and intra-peritoneal hemorrhage, pneumoperitoneum, neoplasm, pancreatitis, ascites and multiple bone fracture. We present a case of 40-year female who underwent emergency cesarean section and developed abdominal compartment syndrome due to urinary bladder distension secondary to blockade of urinary catheter with blood clots. This is a very unusual cause of ACS. (author)

  10. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  11. Evaluation on correction factor for in-line X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Mingli; Huang, Zhifeng; Zhang, Li; Zhang, Ran [Tsinghua Univ., Beijing (China). Dept. of Engineering Physics; Ministry of Education, Beijing (China). Key Laboratory of Particle and Radiation Imaging; Yin, Hongxia; Liu, Yunfu; Wang, Zhenchang [Capital Medical Univ., Beijing (China). Medical Imaging Center; Xiao, Tiqiao [Chinese Academy of Sciences, Shanghai (China). Shanghai Inst. of Applied Physics

    2011-07-01

    X-ray in-line phase contrast computed tomography (CT) is an effective nondestructive tool, providing 3D distribution of the refractive index of weakly absorbing low-Z object with high resolution and image contrast, especially with high-brilliance third-generation synchrotron radiation sources. Modified Bronnikov's algorithm (MBA), one of the in-line phase contrast CT reconstruction algorithms, can reconstruct the refractive index distribution of a pure phase object with a single computed tomographic data set. The key idea of the MBA is to use a correction factor in the filter function to stabilize the behavior at low frequencies. In this paper, we evaluate the influences of the correction factor to the final reconstruction results of the absorption-phase-mixed objects with analytical simulation and actual experiments. The limitations of the MBA are discussed finally. (orig.)

  12. Quantitative evaluation of a single-distance phase-retrieval method applied on in-line phase-contrast images of a mouse lung

    International Nuclear Information System (INIS)

    Mohammadi, Sara; Larsson, Emanuel; Alves, Frauke; Dal Monego, Simeone; Biffi, Stefania; Garrovo, Chiara; Lorenzon, Andrea; Tromba, Giuliana; Dullin, Christian

    2014-01-01

    Quantitative analysis concerning the application of a single-distance phase-retrieval algorithm on in-line phase-contrast images of a mouse lung at different sample-to-detector distances is presented. Propagation-based X-ray phase-contrast computed tomography (PBI) has already proven its potential in a great variety of soft-tissue-related applications including lung imaging. However, the strong edge enhancement, caused by the phase effects, often hampers image segmentation and therefore the quantitative analysis of data sets. Here, the benefits of applying single-distance phase retrieval prior to the three-dimensional reconstruction (PhR) are discussed and quantified compared with three-dimensional reconstructions of conventional PBI data sets in terms of contrast-to-noise ratio (CNR) and preservation of image features. The PhR data sets show more than a tenfold higher CNR and only minor blurring of the edges when compared with PBI in a predominately absorption-based set-up. Accordingly, phase retrieval increases the sensitivity and provides more functionality in computed tomography imaging

  13. Optimization of X-ray phase-contrast imaging based on in-line holography

    International Nuclear Information System (INIS)

    Wu Xizeng; Liu Hong; Yan Aimin

    2005-01-01

    This paper introduces a newly conceived formalism for clinical in-line phase-contrast X-ray imaging. The new formalism applies not only to ideal 'thin' objects analyzed in previous studies, but also applies to the real-world tissues used in actual clinical practice. Moreover we have identified the four clinically important factors that affect phase-contrast characteristics. These factors are: (1) body part attenuation (2) the spatial coherence of incident X-rays from an X-ray tube (3) the polychromatic nature of the X-ray source and (4) radiation dose to patients for clinical applications. Techniques of phase image-reconstruction based on the new X-ray in-line holography theory are discussed. Numerical simulations are described which were used to validate the theory. The design parameters of an optimal clinical phase-contrast mammographic imaging system which were determined based on the new theory, and validated in the simulations, are presented. The theory, image reconstruction algorithms, and numerical simulation techniques presented in this paper can be applied widely to clinical diagnostic X-ray imaging applications

  14. High-throughput, high-resolution X-ray phase contrast tomographic microscopy for visualisation of soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, S A; Marone, F; Hintermueller, C; Stampanoni, M [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Bensadoun, J-C; Aebischer, P, E-mail: samuel.mcdonald@psi.c [EPFL, School of Life Sciences, Station 15, 1015 Lausanne (Switzerland)

    2009-09-01

    The use of conventional absorption based X-ray microtomography can become limited for samples showing only very weak absorption contrast. However, a wide range of samples studied in biology and materials science can produce significant phase shifts of the X-ray beam, and thus the use of the phase signal can provide substantially increased contrast and therefore new and otherwise inaccessible information. The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomography, both available on the TOMCAT beamline of the SLS, is illustrated. Differential Phase Contrast (DPC) imaging uses a grating interferometer and a phase-stepping technique. It has been integrated into the beamline environment on TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. The second phase contrast approach is a modified transfer of intensity approach that can yield the 3D distribution of the phase (refractive index) of a weakly absorbing object from a single tomographic dataset. These methods are being used for the evaluation of cell integrity in 3D, with the specific aim of following and analyzing progressive cell degeneration to increase knowledge of the mechanistic events of neurodegenerative disorders such as Parkinson's disease.

  15. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Thorelius, Lars E-mail: lars@thorelius.com

    2004-06-01

    Ultrasound imaging (US) is a convenient, inexpensive and non-invasive investigation. Its use is limited by low sensitivity in the detection of a number of parenchymal lesions, especially those produced by trauma, such as infarctions. Contrast enhancement with SonoVue{sup [reg]} improves the sensitivity of ultrasound in the detection and characterization of focal liver lesions to such an extent, that it may replace computed tomography (CT) and magnetic resonance imaging (MRI). Preliminary experience suggests that SonoVue-enhanced sonography may be useful in the detection of lesions in which blood flow is severely reduced as compared to surrounding parenchyma, such as infarctions, lacerations, hematomas, necrotic tissue and non-vascular cysts, especially in the spleen, kidney and pancreas. This technique can also rule out occlusion of the superior mesenteric, splenic and portal veins, and dilation of the biliary tree. Clinical trials comparing contrast-enhanced sonography with contrast-enhanced computed tomography are warranted to establish the role of this inexpensive and non-invasive technique in the routine work-up of patients with abdominal trauma or presenting with sudden flank pain.

  16. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  17. Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach

    Energy Technology Data Exchange (ETDEWEB)

    Fredenberg, Erik; Danielsson, Mats; Stayman, J. Webster; Siewerdsen, Jeffrey H.; Aslund, Magnus [Research and Development, Philips Women' s Healthcare, Smidesvaegen 5, SE-171 41 Solna, Sweden and Department of Physics, Royal Institute of Technology, AlbaNova, SE-106 91 Stockholm (Sweden); Department of Physics, Royal Institute of Technology, AlbaNova, SE-106 91 Stockholm (Sweden); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Department of Biomedical Engineering and Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Research and Development, Philips Women' s Healthcare, Smidesvaegen 5, SE-171 41 Solna (Sweden)

    2012-09-15

    Purpose: To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-dose, equal-geometry, and, to some extent, equal-photon-economy constraints. The focus is a geometry for photon-counting mammography. Methods: Phase-contrast imaging is a promising technology that may emerge as an alternative or adjunct to conventional absorption contrast. In particular, phase contrast may increase the signal-difference-to-noise ratio compared to absorption contrast because the difference in phase shift between soft-tissue structures is often substantially larger than the absorption difference. We have developed a comprehensive cascaded-systems framework to investigate Talbot interferometry, which is a technique for differential phase-contrast imaging. Analytical expressions for the MTF and NPS were derived to calculate the NEQ and a task-specific ideal-observer detectability index under assumptions of linearity and shift invariance. Talbot interferometry was compared to absorption contrast at equal dose, and using either a plane wave or a spherical wave in a conceivable mammography geometry. The impact of source size and spectrum bandwidth was included in the framework, and the trade-off with photon economy was investigated in some detail. Wave-propagation simulations were used to verify the analytical expressions and to generate example images. Results: Talbot interferometry inherently detects the differential of the phase, which led to a maximum in NEQ at high spatial frequencies, whereas the absorption-contrast NEQ decreased monotonically with frequency. Further, phase contrast detects differences in density rather than atomic number, and the optimal imaging energy was found to be a factor of 1.7 higher than for absorption

  18. Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach

    International Nuclear Information System (INIS)

    Fredenberg, Erik; Danielsson, Mats; Stayman, J. Webster; Siewerdsen, Jeffrey H.; Åslund, Magnus

    2012-01-01

    Purpose: To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-dose, equal-geometry, and, to some extent, equal-photon-economy constraints. The focus is a geometry for photon-counting mammography. Methods: Phase-contrast imaging is a promising technology that may emerge as an alternative or adjunct to conventional absorption contrast. In particular, phase contrast may increase the signal-difference-to-noise ratio compared to absorption contrast because the difference in phase shift between soft-tissue structures is often substantially larger than the absorption difference. We have developed a comprehensive cascaded-systems framework to investigate Talbot interferometry, which is a technique for differential phase-contrast imaging. Analytical expressions for the MTF and NPS were derived to calculate the NEQ and a task-specific ideal-observer detectability index under assumptions of linearity and shift invariance. Talbot interferometry was compared to absorption contrast at equal dose, and using either a plane wave or a spherical wave in a conceivable mammography geometry. The impact of source size and spectrum bandwidth was included in the framework, and the trade-off with photon economy was investigated in some detail. Wave-propagation simulations were used to verify the analytical expressions and to generate example images. Results: Talbot interferometry inherently detects the differential of the phase, which led to a maximum in NEQ at high spatial frequencies, whereas the absorption-contrast NEQ decreased monotonically with frequency. Further, phase contrast detects differences in density rather than atomic number, and the optimal imaging energy was found to be a factor of 1.7 higher than for absorption

  19. Does abdominal obesity accelerate the effect of hypertriglyceridemia on impaired fasting glucose?

    Science.gov (United States)

    Lee, Soojin; Chun, Kihong; Lee, Soonyoung; Kim, Daejung

    2010-05-01

    This study sought to determine whether abdominal obesity is a risk factor for impaired fasting glucose (IFG) and hypertriglyceridemia and to verify whether moderate effect of abdominal obesity on the relationship between IFG and hypertriglyceridemia in Korea. Data from the Korean National Health and Nutrition Examination Survey was used for the analysis. The study population included 5,938 subjects aged 20 year old drawn from non-diabetic participants in a health examination survey. The subjects were classified according to the presence of abdominal obesity based on waist circumference, IFG based on their fasting blood glucose level, and hypertriglyceridemia on their fasting triglyceride. The multivariate-adjusted odds ratios for the occurrence of hypertriglyceridemia were 2.91 in the abdominal obesity group as compared with the nonobesity group and 1.31 in subjects with IFG compared with the normoglycemia controls. Abdominal obesity was found to be positively moderated in the interaction between waist circumference and fasting blood sugar. The moderate effect between abdominal obesity and IFG contributes to the development of hypertriglyceridemia in Korea.

  20. Binocular contrast-gain control for natural scenes: Image structure and phase alignment.

    Science.gov (United States)

    Huang, Pi-Chun; Dai, Yu-Ming

    2018-05-01

    In the context of natural scenes, we applied the pattern-masking paradigm to investigate how image structure and phase alignment affect contrast-gain control in binocular vision. We measured the discrimination thresholds of bandpass-filtered natural-scene images (targets) under various types of pedestals. Our first experiment had four pedestal types: bandpass-filtered pedestals, unfiltered pedestals, notch-filtered pedestals (which enabled removal of the spatial frequency), and misaligned pedestals (which involved rotation of unfiltered pedestals). Our second experiment featured six types of pedestals: bandpass-filtered, unfiltered, and notch-filtered pedestals, and the corresponding phase-scrambled pedestals. The thresholds were compared for monocular, binocular, and dichoptic viewing configurations. The bandpass-filtered pedestal and unfiltered pedestals showed classic dipper shapes; the dipper shapes of the notch-filtered, misaligned, and phase-scrambled pedestals were weak. We adopted a two-stage binocular contrast-gain control model to describe our results. We deduced that the phase-alignment information influenced the contrast-gain control mechanism before the binocular summation stage and that the phase-alignment information and structural misalignment information caused relatively strong divisive inhibition in the monocular and interocular suppression stages. When the pedestals were phase-scrambled, the elimination of the interocular suppression processing was the most convincing explanation of the results. Thus, our results indicated that both phase-alignment information and similar image structures cause strong interocular suppression. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  2. Multiscale differential phase contrast analysis with a unitary detector

    KAUST Repository

    Lopatin, Sergei; Ivanov, Yurii P.; Kosel, Jü rgen; Chuvilin, Andrey

    2015-01-01

    A new approach to generate differential phase contrast (DPC) images for the visualization and quantification of local magnetic fields in a wide range of modern nano materials is reported. In contrast to conventional DPC methods our technique utilizes the idea of a unitary detector under bright field conditions, making it immediately usable by a majority of modern transmission electron microscopes. The approach is put on test to characterize the local magnetization of cylindrical nanowires and their 3D ordered arrays, revealing high sensitivity of our method in a combination with nanometer-scale spatial resolution.

  3. Multiscale differential phase contrast analysis with a unitary detector

    KAUST Repository

    Lopatin, Sergei

    2015-12-30

    A new approach to generate differential phase contrast (DPC) images for the visualization and quantification of local magnetic fields in a wide range of modern nano materials is reported. In contrast to conventional DPC methods our technique utilizes the idea of a unitary detector under bright field conditions, making it immediately usable by a majority of modern transmission electron microscopes. The approach is put on test to characterize the local magnetization of cylindrical nanowires and their 3D ordered arrays, revealing high sensitivity of our method in a combination with nanometer-scale spatial resolution.

  4. Ferumoxytol as an off-label contrast agent in body 3T MR angiography: a pilot study in children

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, Department of Radiology, Stanford, CA (United States); Hsiao, Albert; Vasanawala, Shreyas S. [Stanford University, Department of Radiology, Stanford, CA (United States)

    2015-06-15

    Ferumoxytol is an ultrasmall superparamagnetic iron oxide (USPIO) nanoparticle agent used to treat iron deficiency anemia in adults with chronic kidney disease. We aim to determine the feasibility of using ferumoxytol for clinical pediatric cardiac and vascular imaging. We retrospectively identified 23 consecutive children who underwent MRI with ferumoxytol (11 males; mean age: 7.4 years, range: 3 days-18 years), yielding 12 abdominal MR angiography and 15 cardiac MRI studies. Medical records were reviewed for the clinical indication, ferumoxytol dose, injection rate, sedation and any complication. A two-reader consensus scored the images on a five-point scale for overall image quality and delineation of various anatomical structures. Signal-to-background ratios for abdominal aorta and inferior vena cava for abdominal cases and blood pool-myocardium contrast ratios for cardiac cases were calculated. The confidence intervals for obtaining a score of three or above for each image parameter were calculated by using adjusted Wald method. For abdominal MR angiography, average scores for overall image quality, as well as delineation of the hepatic artery, superior mesenteric artery, renal artery and veins were 4.5, 4.3, 4.3, 3.7 and 4.7, respectively. For cardiac exams, the average scores for overall image quality, systemic arteries, pulmonary arteries, pulmonary veins, valves and ventricles were 4.4, 4.6, 4.1, 4.8, 4.1 and 4.7, respectively. For all parameters, the lower bound for the proportion of cases to have a score of 3 or above was 65%. Signal-to-background ratios for aorta and abdominal veins averaged 86 +/- 74 and 86 +/- 77 for full-dose images, and 23 and 18 for half-dose images, respectively. Mean blood pool to myocardium contrast ratio was 3:3. Ferumoxytol can provide excellent image quality for pediatric body MR angiography/MR venography at a dose of 1.5 or 3 mg Fe/kg. Further investigation should be directed toward understanding the lowest dose that can be

  5. The ‘abdominal circulatory pump’: an auxiliary heart during exercise?

    Directory of Open Access Journals (Sweden)

    Barbara eUva

    2016-01-01

    Full Text Available Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25±7yr, 70±11kg, 1.78±0.1m, 3F performed plantar flexion exercise at ∼4 METs. Changes in body volume (ΔVb and trunk volume (ΔVtr were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE, rib cage (RCE, voluntary emphasized inspiratory rib cage breathing and abdominal (ABE, voluntary active abdominal expiration breathing.. During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16± 0.33L and 0.48±0.55L, p<0.05 SE vs RCE, while during ABE it was displaced from the trunk to the extremities (0.22±0.20L p<0.001, p<0.05 RCE and SE vs ABE respectively. At baseline, Vbs swings (maximum to minimum amplitude were bimodal and averaged 0.13±0.08L. During exercise, Vbs swings consistently increased (0.42±0.34L, 0.40±0.26L, 0.46±0.21L, for SE, RCE and ABE respectively, all p<0.01 vs. baseline. It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an ‘auxiliary heart’.

  6. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis.

    Science.gov (United States)

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-10-10

    We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity.

  7. Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution.

    Science.gov (United States)

    Huang, Chong; Irwin, Daniel; Zhao, Mingjun; Shang, Yu; Agochukwu, Nneamaka; Wong, Lesley; Yu, Guoqiang

    2017-10-01

    Recent advancements in near-infrared diffuse correlation techniques and instrumentation have opened the path for versatile deep tissue microvasculature blood flow imaging systems. Despite this progress there remains a need for a completely noncontact, noninvasive device with high translatability from small/testing (animal) to large/target (human) subjects with trivial application on both. Accordingly, we discuss our newly developed setup which meets this demand, termed noncontact speckle contrast diffuse correlation tomography (nc_scDCT). The nc_scDCT provides fast, continuous, portable, noninvasive, and inexpensive acquisition of 3-D tomographic deep (up to 10 mm) tissue blood flow distributions with straightforward design and customization. The features presented include a finite-element-method implementation for incorporating complex tissue boundaries, fully noncontact hardware for avoiding tissue compression and interactions, rapid data collection with a diffuse speckle contrast method, reflectance-based design promoting experimental translation, extensibility to related techniques, and robust adjustable source and detector patterns and density for high resolution measurement with flexible regions of interest enabling unique application-specific setups. Validation is shown in the detection and characterization of both high and low contrasts in flow relative to the background using tissue phantoms with a pump-connected tube (high) and phantom spheres (low). Furthermore, in vivo validation of extracting spatiotemporal 3-D blood flow distributions and hyperemic response during forearm cuff occlusion is demonstrated. Finally, the success of instrument feasibility in clinical use is examined through the intraoperative imaging of mastectomy skin flap.

  8. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction

    International Nuclear Information System (INIS)

    Hwang, Shin Hye; You, Je Sung; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Song, Mi Kyong

    2015-01-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. (orig.)

  9. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Shin Hye; You, Je Sung; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Seodaemun-gu, Seoul (Korea, Republic of); Song, Mi Kyong [Yonsei University, Biostatistics Collaboration Unit, College of Medicine, Seoul (Korea, Republic of)

    2015-04-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. (orig.)

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... as ulcerative colitis or Crohn's disease , pancreatitis or liver cirrhosis. cancers of the liver, kidneys, pancreas, ovaries and ... abdominal conditions in babies, such as vomiting or blood in stool. For some conditions, including but not limited to some liver, kidney, pancreatic, uterine or ... Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  11. Measurements and simulations analysing the noise behaviour of grating-based X-ray phase-contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Weber, T., E-mail: thomas.weber@physik.uni-erlangen.de [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); Bartl, P.; Durst, J. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); Haas, W. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); University of Erlangen-Nuremberg, Pattern Recognition Lab, Martensstr. 3, 91058 Erlangen (Germany); Michel, T.; Ritter, A.; Anton, G. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany)

    2011-08-21

    In the last decades, phase-contrast imaging using a Talbot-Lau grating interferometer is possible even with a low-brilliance X-ray source. With the potential of increasing the soft-tissue contrast, this method is on its way into medical imaging. For this purpose, the knowledge of the underlying physics of this technique is necessary. With this paper, we would like to contribute to the understanding of grating-based phase-contrast imaging by presenting results on measurements and simulations regarding the noise behaviour of the differential phases. These measurements were done using a microfocus X-ray tube with a hybrid, photon-counting, semiconductor Medipix2 detector. The additional simulations were performed by our in-house developed phase-contrast simulation tool 'SPHINX', combining both wave and particle contributions of the simulated photons. The results obtained by both of these methods show the same behaviour. Increasing the number of photons leads to a linear decrease of the standard deviation of the phase. The number of used phase steps has no influence on the standard deviation, if the total number of photons is held constant. Furthermore, the probability density function (pdf) of the reconstructed differential phases was analysed. It turned out that the so-called von Mises distribution is the physically correct pdf, which was also confirmed by measurements. This information advances the understanding of grating-based phase-contrast imaging and can be used to improve image quality.

  12. Elderly female with acute abdominal pain presenting with Superior Mesenteric Artery Thrombus

    Directory of Open Access Journals (Sweden)

    Sassan Ghassemzadeh, MD

    2018-04-01

    Full Text Available History of present illness: An 80-year-old female with history of hypertension and atrial fibrillation, presented with sudden onset of abdominal pain after eating at a restaurant. The patient denied any fever, vomiting or diarrhea. She admitted to being noncompliant with medications including warfarin. Initial vital signs were within normal limits. On exam, the patient was very uncomfortable and could not lay still in bed, even after multiple doses of intravenous narcotic pain medications. The patient had generalized abdominal tenderness without rebound or guarding. Labs revealed a white-blood-cell count of 13.8, lactic acid of 3.6, and international normalized ratio (INR of 1.1, with normal renal function. Significant findings: Computed tomography (CT angiogram of the abdomen and pelvis revealed a superior mesenteric artery (SMA thrombosis 5 cm from the origin off of the abdominal aorta. As seen in the sagittal view, there does not appear to be any contrast 5 cm past the origin of the SMA. On the axial views, you can trace the SMA until the point that there is no longer any contrast visible which indicates the start of the thrombus. The SMA does not appear to be reconstituted. There was normal flow to the celiac artery. (See annotated images. Discussion: This case involves a classic presentation of acute mesenteric ischemia, which is defined as the sudden onset of abdominal pain due to small intestinal hypo-perfusion secondary to reduction or complete occlusion of arterial blood flow to the intestines. The most common artery affected is the SMA. The main two reasons for this phenomenon are either due to an arterial embolus or from arterial thrombus from underlying atherosclerosis. The ratio of superior mesenteric embolus to thrombus has been shown to be 1.4:1.1 Embolism to the mesenteric arteries is most frequently from a thrombus that breaks off from the left atrium, left ventricle, or proximal aorta, as in this case from underlying atrial

  13. Theory and preliminary experimental verification of quantitative edge illumination x-ray phase contrast tomography.

    Science.gov (United States)

    Hagen, C K; Diemoz, P C; Endrizzi, M; Rigon, L; Dreossi, D; Arfelli, F; Lopez, F C M; Longo, R; Olivo, A

    2014-04-07

    X-ray phase contrast imaging (XPCi) methods are sensitive to phase in addition to attenuation effects and, therefore, can achieve improved image contrast for weakly attenuating materials, such as often encountered in biomedical applications. Several XPCi methods exist, most of which have already been implemented in computed tomographic (CT) modality, thus allowing volumetric imaging. The Edge Illumination (EI) XPCi method had, until now, not been implemented as a CT modality. This article provides indications that quantitative 3D maps of an object's phase and attenuation can be reconstructed from EI XPCi measurements. Moreover, a theory for the reconstruction of combined phase and attenuation maps is presented. Both reconstruction strategies find applications in tissue characterisation and the identification of faint, weakly attenuating details. Experimental results for wires of known materials and for a biological object validate the theory and confirm the superiority of the phase over conventional, attenuation-based image contrast.

  14. Using machine-learning to optimize phase contrast in a low-cost cellphone microscope

    Science.gov (United States)

    Wartmann, Rolf; Schadwinkel, Harald; Heintzmann, Rainer

    2018-01-01

    Cellphones equipped with high-quality cameras and powerful CPUs as well as GPUs are widespread. This opens new prospects to use such existing computational and imaging resources to perform medical diagnosis in developing countries at a very low cost. Many relevant samples, like biological cells or waterborn parasites, are almost fully transparent. As they do not exhibit absorption, but alter the light’s phase only, they are almost invisible in brightfield microscopy. Expensive equipment and procedures for microscopic contrasting or sample staining often are not available. Dedicated illumination approaches, tailored to the sample under investigation help to boost the contrast. This is achieved by a programmable illumination source, which also allows to measure the phase gradient using the differential phase contrast (DPC) [1, 2] or even the quantitative phase using the derived qDPC approach [3]. By applying machine-learning techniques, such as a convolutional neural network (CNN), it is possible to learn a relationship between samples to be examined and its optimal light source shapes, in order to increase e.g. phase contrast, from a given dataset to enable real-time applications. For the experimental setup, we developed a 3D-printed smartphone microscope for less than 100 $ using off-the-shelf components only such as a low-cost video projector. The fully automated system assures true Koehler illumination with an LCD as the condenser aperture and a reversed smartphone lens as the microscope objective. We show that the effect of a varied light source shape, using the pre-trained CNN, does not only improve the phase contrast, but also the impression of an improvement in optical resolution without adding any special optics, as demonstrated by measurements. PMID:29494620

  15. Functional abdominal pain syndrome treated with Korean medication

    Directory of Open Access Journals (Sweden)

    Chang-Gue Son

    2014-06-01

    Full Text Available A 37-year-old female patient with chronic and stubborn abdominal pain had been hospitalized five times in three Western hospitals, but no effects were observed. No abnormalities were found in blood tests, gastrointestinal endoscopy, sonogram, and computed tomography of the abdomen, except mild paralytic ileus. The patient decided to rely on Korean medicine as an inpatient. She was diagnosed with functional abdominal pain syndrome, and her symptom differentiation was the “Yang deficiency of spleen and kidney.” A herbal drug, Hwangikyeji-tang, along with moxibustion and acupuncture, was given to the patient. Abdominal pain and related symptoms were reduced radically within 16 days of treatment. This report shows a therapeutic potential of Korean medicine-based treatment for functional abdominal pain syndrome.

  16. Functional abdominal pain syndrome treated with Korean medication.

    Science.gov (United States)

    Son, Chang-Gue

    2014-06-01

    A 37-year-old female patient with chronic and stubborn abdominal pain had been hospitalized five times in three Western hospitals, but no effects were observed. No abnormalities were found in blood tests, gastrointestinal endoscopy, sonogram, and computed tomography of the abdomen, except mild paralytic ileus. The patient decided to rely on Korean medicine as an inpatient. She was diagnosed with functional abdominal pain syndrome, and her symptom differentiation was the " Yang deficiency of spleen and kidney ." A herbal drug, Hwangikyeji-tang , along with moxibustion and acupuncture, was given to the patient. Abdominal pain and related symptoms were reduced radically within 16 days of treatment. This report shows a therapeutic potential of Korean medicine-based treatment for functional abdominal pain syndrome.

  17. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  18. X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Lee, Sang Joon

    2016-01-18

    X-ray PIV measurement is a noninvasive approach to measure opaque blood flows. However, it is not easy to measure real pulsatile blood flows in the blood vessels located at deep position of the body, because the surrounding tissues significantly attenuate the contrast of X-ray images. This study investigated the effect of surrounding tissues on X-ray beam attenuation by measuring the velocity fields of blood flows in deep vessels of a live rat. The decrease in image contrast was minimized by employing biocompatible CO2 microbubbles as tracer particles. The maximum measurable velocity of blood flows in the abdominal aorta of a rat model was found through comparative examination between the PIV measurement accuracy and the level of image contrast according to the input flow rate. Furthermore, the feasibility of using X-ray PIV to accurately measure in vivo blood flows was demonstrated by determining the velocity field of blood flows in the inferior vena cava of a rat. This study may serve as a reference in conducting in vivo X-ray PIV measurements of pulsatile blood flows in animal disease models and investigating hemodynamic characteristics and circulatory vascular diseases.

  19. Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

    International Nuclear Information System (INIS)

    Ng, I.; Fouras, A.; Paganin, D. M.

    2012-01-01

    Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 μm air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error ( 15 μm) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 μm), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

  20. Diagnostic accuracy of contrast enhanced ultrasound in patients with blunt abdominal trauma presenting to the emergency department: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Zhongheng; Hong, Yucai; Liu, Ning; Chen, Yuhao

    2017-06-30

    We aimed to investigate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in evaluating blunt abdominal trauma for patients presenting to the emergency department. Electronic search of Scopus and Pubmed was performed from inception to September 2016. Human studies investigating the diagnostic accuracy of CEUS in identifying abdominal solid organ injuries were included. Risk of bias was assessed using the QUADAS tool. A total of 10 studies were included in the study and 9 of them were included for meta-analysis. The log(DOR) values ranged from 3.80 (95% CI: 2.81-4.79) to 8.52 (95% CI: 4.58-12.47) in component studies. The combined log(DOR) was 6.56 (95% CI: 5.66-7.45). The Cochran's Q was 11.265 (p = 0.793 with 16 degrees of freedom), and the Higgins' I 2 was 0%. The CEUS had a sensitivity of 0.981 (95% CI: 0.868-0.950) and a false positive rate of 0.018 (95% CI: 0.010-0.032) for identifying parenchymal injuries, with an AUC of 0.984. CEUS performed at emergency department had good diagnostic accuracy in identifying abdominal solid organ injuries. CEUS can be recommended in monitoring solid organ injuries, especially for patients managed with non-operative strategy.

  1. Variation in supratentorial cerebrospinal fluid production rate in one day. Measurement by nontriggered phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takahashi, Hiroto; Tanaka, Hisashi; Fujita, Norihiko; Murase, Kenya; Tomiyama, Noriyuki

    2011-01-01

    Measuring the cerebrospinal fluid (CSF) production rate is important for understanding the physiology related to normal conditions and neurological disorders. Triggered phase-contrast magnetic resonance imaging (MRI) has been used to measure CSF production rate, but the use of nontriggered phase-contrast MRI has not been reported. The purposes of this study were to assess the feasibility of using nontriggered phase-contrast MRI to measure CSF flow and to determine whether CSF production exhibits circadian rhythm. The feasibility of phase-contrast MRI was assessed with a phantom simulated human cerebral aqueduct. CSF flow through the cerebral aqueduct was measured with nontriggered phase-contrast MRI four times during 1 day in 10 normal volunteers. In the phantom study, linear regression analysis gave the following measured values (ml/h): 0.80 x (value of steady flow)-10.0 for triggered phase-contrast MRI and 1.27 x (value of steady flow)-12.2 for nontriggered phase-contrast MRI. One-factor analysis of variance showed no significant effect of the time of the measurements (P=0.47). The supratentorial CSF production rate was 510±549 ml/day (mean ± SD). Nontriggered phase-contrast MRI provided good estimates of the flow rate in the phantom study. We observed no circadian rhythm in CSF production. (author)

  2. Correlation between blood and lymphatic vessel density and results of contrast-enhanced spectral mammography.

    Science.gov (United States)

    Luczynska, Elzbieta; Niemiec, Joanna; Ambicka, Aleksandra; Adamczyk, Agnieszka; Walasek, Tomasz; Ryś, Janusz; Sas-Korczyńska, Beata

    2015-09-01

    Contrast-enhanced spectral mammography (CESM) is a novel technique used for detection of tumour vascularity by imaging the moment in which contrast, delivered to the lesion by blood vessels, leaks out of them, and flows out through lymphatic vessels. In our study, we included 174 women for whom spectral mammography was performed for diagnostic purposes. The relationship between enhancement in CESM and blood vessel density (BVD), lymphatic vessel density (LVD) or the percentage of fields with at least one lymphatic vessel (distribution of podoplanin-positive vessels - DPV) and other related parameters was assessed in 55 cases. BVD, LVD and DPV were assessed immunohistochemically, applying podoplanin and CD31/CD34 as markers of lymphatic and blood vessels, respectively. The sensitivity (in detection of malignant lesions) of CESM was 100%, while its specificity - 39%. We found a significant positive correlation between the intensity of enhancement in CESM and BVD (p = 0.007, r = 0.357) and a negative correlation between the intensity of enhancement in CESM and DPV (p = 0.003, r = -0.390). Lesions with the highest enhancement in CESM showed a high number of blood vessels and a low number of lymphatics. 1) CESM is a method characterized by high sensitivity and acceptable specificity; 2) the correlation between CESM results and blood/lymphatic vessel density confirms its utility in detection of tissue angiogenesis and/or lymphangiogenesis.

  3. Current practice vs. guideline based imaging in abdominal radiology in the German speaking area. Results of an online survey; Versorgungsrealitaet vs. leitliniengerechte Bildgebung in der Abdominalradiologie im deutschsprachigen Raum. Ergebnisse einer Online-Umfrage

    Energy Technology Data Exchange (ETDEWEB)

    Schreyer, A.G. [University Hospital Regenburg (Germany). Dept. of Radiology; Wessling, J. [Clemens Hospital Muenchen (Germany). Dept. of Radiology; Grenacher, L. [Diagnostic Muenchen (Germany). Diagnostic Imaging Center

    2016-03-15

    The working group for abdominal imaging within the German Roentgen Society (DRG) performed an online survey amongst radiologist concerning the current status of techniques for abdominal imaging. The results of this survey were compared with the most recent guidelines. We performed an online survey open for all members of the DRG during a 76-day period with 65 questions and an overall estimated time for finishing the questionnaire of 15 minutes concerning technical specifications for abdominal radiological imaging. The results were evaluated using descriptive statistics. 90 of all participants, who filled out the survey covering more than 80 % of the questions, were included in the statistical evaluation. 27 % of all participants were registered radiologists while 73 % represented radiologists working in a hospital. Most participants worked in a managerial position. The participants gave detailed information regarding the radiological techniques used in dedicated organ systems (esophagus, stomach, pancreas, liver, small intestines, colon) regarding acquired contrast phases and oral and intravenous administration of contrast medium. The results confirm that most radiologists participating in this survey perform their examinations and choose their modalities in conformity with the current existing clinical guidelines. Because most clinical guidelines do not specify radiological examinations in detail, there is a noteworthy heterogeneity of the acquired contrast phases and major divergence in terms of technical parameters. Therefore a joint radiological effort should be initiated for developing and publishing updated radiological parameters for abdominal imaging.

  4. Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kwon-Ha; Ryu, Jong-Hyun; Jung, Chang-Won [Wonkwang University School of Medicine, Iksan (Korea, Republic of); Ryu, Cheol-Woo; Kim, Young-Jo; Kwon, Young-Man [Jeonbuk Technopark, Iksan (Korea, Republic of); Park, Mi-Ran; Cho, Seung-Ryong [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Chon, Kwon-Su [Catholic University of Daegu, Gyeongsan (Korea, Republic of)

    2014-12-15

    X-ray phase-contrast imaging can provide images with much greater soft-tissue contrast than conventional absorption-based images. In this paper, we describe differential X-ray phase-contrast images of insect specimens that were obtained using a grating-based Talbot interferometer and a laboratory X-ray source with a spot size of a few tens of micrometers. We developed the interferometer on the basis of the wavelength, periods, and height of the gratings; the field of view depends on the size of the grating, considering the refractive index of the specimen. The phase-contrast images were acquired using phase-stepping methods. The phase contrast imaging provided a significantly enhanced soft-tissue contrast compared with the attenuation data. The contour of the sample was clearly visible because the refraction from the edges of the object was strong in the differential phase-contrast image. Our results demonstrate that a grating-based Talbot interferometer with a conventional X-ray tube may be attractive as an X-ray imaging system for generating phase images. X-ray phase imaging obviously has sufficient potential and is expected to soon be a great tool for medical diagnostics.

  5. Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube

    International Nuclear Information System (INIS)

    Yoon, Kwon-Ha; Ryu, Jong-Hyun; Jung, Chang-Won; Ryu, Cheol-Woo; Kim, Young-Jo; Kwon, Young-Man; Park, Mi-Ran; Cho, Seung-Ryong; Chon, Kwon-Su

    2014-01-01

    X-ray phase-contrast imaging can provide images with much greater soft-tissue contrast than conventional absorption-based images. In this paper, we describe differential X-ray phase-contrast images of insect specimens that were obtained using a grating-based Talbot interferometer and a laboratory X-ray source with a spot size of a few tens of micrometers. We developed the interferometer on the basis of the wavelength, periods, and height of the gratings; the field of view depends on the size of the grating, considering the refractive index of the specimen. The phase-contrast images were acquired using phase-stepping methods. The phase contrast imaging provided a significantly enhanced soft-tissue contrast compared with the attenuation data. The contour of the sample was clearly visible because the refraction from the edges of the object was strong in the differential phase-contrast image. Our results demonstrate that a grating-based Talbot interferometer with a conventional X-ray tube may be attractive as an X-ray imaging system for generating phase images. X-ray phase imaging obviously has sufficient potential and is expected to soon be a great tool for medical diagnostics

  6. Imaging of metastatic lymph nodes by X-ray phase-contrast micro-tomography

    DEFF Research Database (Denmark)

    Jensen, Torben Haugaard; Bech, Martin; Binderup, Tina

    2013-01-01

    -contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study...

  7. Detecção de hipertensão arterial em adolescentes através de marcadores gerais e adiposidade abdominal Detección de hipertensión arterial en adolescentes por medio de marcadores generales y adiposidad abdominal High blood pressure detection in adolescents by clustering overall and abdominal adiposity markers

    Directory of Open Access Journals (Sweden)

    Diego G. D Christofaro

    2011-06-01

    Full Text Available FUNDAMENTO: A obesidade está ligada à hipertensão arterial (HA na infância. Entretanto, o papel da gordura como preditor de HA em adolescentes permanece desconhecido. OBJETIVO: Investigar a associação entre obesidade geral e abdominal com HA e identificar a sensibilidade e especificidade desses indicadores para detectar HA em adolescentes. MÉTODOS: A amostra consistiu em 1.021 adolescentes com idade de 10-17 anos. Os indivíduos foram classificados como normal, sobrepeso/obesidade, de acordo com as medidas do IMC, e como não-obeso com obesidade abdominal, de acordo com as medidas da circunferência da cintura (CC. A pressão arterial sistólica (PAS e diastólica (PAD foi avaliada através de um dispositivo oscilométrico. Regressão logística e curvas ROC foram usadas na análise estatística. RESULTADOS: A prevalência geral de HA foi 11,8% (13,4% em meninos e 10,2% em meninas. A prevalência de HA em meninos e meninas com sobrepeso/obesidade foi 10% e 11,1%, respectivamente. A prevalência de HA em meninos com obesidade abdominal foi 28,6%. Para ambos os sexos, o odds ratio (OR para HA foi mais alto na obesidade abdominal do que no sobrepeso/obesidade geral (4,09 [OR IC95% = 2,57-6,51] versus 1,83 [OR IC95% = 1,83-4,30]. O OR para HA foi mais alto quando sobrepeso/obesidade geral e obesidade abdominal estavam agrupados (OR = 4,35 [OR IC95% = 2,68 -7,05], do que quando identificados como sobrepeso/obesidade geral ou obesidade abdominal apenas (OR = 1,32 [OR IC95% = 0,65- 2,68]. Entretanto, ambos os tipos de obesidade apresentavam baixo poder preditivo na detecção de HA. CONCLUSÃO: Obesidade geral e obesidade abdominal foram associadas com HA; entretanto, a sensibilidade e especificidade dessas variáveis na detecção de HA são baixas em adolescentes brasileiros.BACKGROUND: Obesity is linked to high blood pressure (HBP in childhood. However, the role of fat as a predictor of HBP in adolescents remains unknown. OBJECTIVE: To

  8. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  9. A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wang Zhi-Li; Gao Kun; Chen Jian; Ge Xin; Tian Yang-Chao; Wu Zi-Yu; Zhu Pei-Ping

    2012-01-01

    Grating-based X-ray phase contrast imaging has been demonstrated to be an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse-projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensional phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method

  10. Anterior abdominal Wall scar endometriosis: Case series and review of imaging modalities

    Directory of Open Access Journals (Sweden)

    Işık Üstüner

    2014-03-01

    Full Text Available Implantation of endometriosis to pelvic and abdominal scar tissue is a very rare occurrence. Most commonly observed after cesarean sections due to implantation of uterine endometrial stem cells to outside tissues. Patients are often asymptomatic but may present with cyclic pain and mass. Imaging diagnosis is possible when classical implantation site near the scar tissue, clinical history and imaging findings are combined. In ultrasound imaging the lesion is often solid, mildly hypoechoic and often isoechoic to surrounding muscle. Presence of bleeding and fluid may cause the lesion to appear more heterogeneous. On computed tomography imaging the most pronounced finding is avid contrast enhancement of the lesion whereas in magnetic resonance imaging sensitivity to blood products.

  11. Phase analysis in gated blood pool tomography. Detection of accessory conduction pathway

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro (Kanazawa Univ. (Japan). School of Medicine)

    1984-02-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome.

  12. X-ray elastography: Modification of x-ray phase contrast images using ultrasonic radiation pressure

    International Nuclear Information System (INIS)

    Hamilton, Theron J.; Bailat, Claude; Rose-Petruck, Christoph; Diebold, Gerald J.; Gehring, Stephan; Laperle, Christopher M.; Wands, Jack

    2009-01-01

    The high resolution characteristic of in-line x-ray phase contrast imaging can be used in conjunction with directed ultrasound to detect small displacements in soft tissue generated by differential acoustic radiation pressure. The imaging method is based on subtraction of two x-ray images, the first image taken with, and the second taken without the presence of ultrasound. The subtraction enhances phase contrast features and, to a large extent, removes absorption contrast so that differential movement of tissues with different acoustic impedances or relative ultrasonic absorption is highlighted in the image. Interfacial features of objects with differing densities are delineated in the image as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. Experiments with ex vivo murine tumors and human tumor phantoms point out a diagnostic capability of the method for identifying tumors.

  13. Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution. Gd-EOB-DTPA versus Gd-DTPA in vivo

    International Nuclear Information System (INIS)

    Fujinaga, Yasunari; Tsukahara, Yoshinori; Sugiyama, Yukiko; Kadoya, Masumi; Ueda, Hitoshi; Kitou, Yoshihiro

    2013-01-01

    The purpose of this study was to evaluate the difference in the time-intensity curves (TICs) of the abdominal aorta on dynamic contrast-enhanced MRI (DCE-MRI) between gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) and gadolinium ethoxybenzydiethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Ten healthy volunteers underwent DCE-MRI three times with the following protocol: group A, Gd-DTPA at an injection rate of 3 ml/s; group B, Gd-EOB-DTPA, 3 ml/s; group C, Gd-EOB-DTPA, 1.5 ml/s. Signal intensities (SIs) of the abdominal aorta were measured, and the contrast enhancement ratio (CER) was calculated. Time-to-CER curves were compared among the three groups. The differences in maximum CER (CER max ) and time-to-peak of CER were analyzed. The time-to-CER curve showed a double peak pattern in group A and single-peak pattern in groups B and C. The mean time between the first and the second peak was 6.2 s. The mean CER max of each group was 4.50, 4.52 and 4.27, respectively. In group A, B and C, the mean time-to-peak was 14.6, 10.6 and 12.6 s, respectively. There was a significant difference between group A and B (P<0.01). To set up the optimal protocol for abdominal DCE-MRI, it should be noted that TIC in the Gd-DTPA and Gd-EOB-DTPA group showed different patterns, and a slower injection rate showed a less abrupt SI change in the Gd-EOB-DTPA group than in the Gd-DTPA group. (author)

  14. Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Raupach, Rainer; Flohr, Thomas G

    2011-01-01

    We analyze the signal and noise propagation of differential phase-contrast computed tomography (PCT) compared with conventional attenuation-based computed tomography (CT) from a theoretical point of view. This work focuses on grating-based differential phase-contrast imaging. A mathematical framework is derived that is able to analytically predict the relative performance of both imaging techniques in the sense of the relative contrast-to-noise ratio for the contrast of any two materials. Two fundamentally different properties of PCT compared with CT are identified. First, the noise power spectra show qualitatively different characteristics implying a resolution-dependent performance ratio. The break-even point is derived analytically as a function of system parameters such as geometry and visibility. A superior performance of PCT compared with CT can only be achieved at a sufficiently high spatial resolution. Second, due to periodicity of phase information which is non-ambiguous only in a bounded interval statistical phase wrapping can occur. This effect causes a collapse of information propagation for low signals which limits the applicability of phase-contrast imaging at low dose.

  15. Imaging modalities of abdominal tumors in children

    International Nuclear Information System (INIS)

    Reither, M.

    1993-01-01

    Further technological progress in cross-sectional imaging modalities, accumuting experience with increasingly refined hardware and software and accumulating specific contrast media allow new algorithms for the assessment of abdominal tumors in children. However, ultrasound remains the diagnostic method of choice: Conventional roentgenology with or without contrast media is decreasing, but often reveals further differential diagnostic details. MRI is becoming more prominent and is often performed immediately after ultrasound. The inauguration of gradient echo sequences and consequent shorter examination times combined with the elimination of pulsation and motion artefacts extends the diagnostic spectrum of the upper and middle abdomen. The application of oral or rectal contrast agents for imaging of the GI tract ameliorates the differentiation of pathologic processes. Recently volumetric CT/ultrafast CT has been gaining in importance for abdominal examinations in the pediatric age group. CT especially is helpful if there are bony structures in the region being examined. CT, however, involves ionizing radiation and timely administration of oral and intravenous contrast material. Moreover, as pediatric radiologists, we must strongly withstand tendencies to perform CT more often because it is less expensive, rather than avoiding ionizing radiation by using MRI. (orig.) [de

  16. Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source

    International Nuclear Information System (INIS)

    Donath, Tilman; Bunk, Oliver; Groot, Waldemar; Bednarzik, Martin; Gruenzweig, Christian; David, Christian; Pfeiffer, Franz; Hempel, Eckhard; Popescu, Stefan; Hoheisel, Martin

    2009-01-01

    Phase-contrast imaging at laboratory-based x-ray sources using grating interferometers has been developed over the last few years for x-ray energies of up to 28 keV. Here, we show first phase-contrast projection and tomographic images recorded at significantly higher x-ray energies, produced by an x-ray tube source operated at 100 kV acceleration voltage. We find our measured tomographic phase images in good agreement with tabulated data. The extension of phase-contrast imaging to this significantly higher x-ray energy opens up many applications of the technique in medicine and industrial nondestructive testing.

  17. Application of Fourier-wavelet regularized deconvolution for improving image quality of free space propagation x-ray phase contrast imaging.

    Science.gov (United States)

    Zhou, Zhongxing; Gao, Feng; Zhao, Huijuan; Zhang, Lixin

    2012-11-21

    New x-ray phase contrast imaging techniques without using synchrotron radiation confront a common problem from the negative effects of finite source size and limited spatial resolution. These negative effects swamp the fine phase contrast fringes and make them almost undetectable. In order to alleviate this problem, deconvolution procedures should be applied to the blurred x-ray phase contrast images. In this study, three different deconvolution techniques, including Wiener filtering, Tikhonov regularization and Fourier-wavelet regularized deconvolution (ForWaRD), were applied to the simulated and experimental free space propagation x-ray phase contrast images of simple geometric phantoms. These algorithms were evaluated in terms of phase contrast improvement and signal-to-noise ratio. The results demonstrate that the ForWaRD algorithm is most appropriate for phase contrast image restoration among above-mentioned methods; it can effectively restore the lost information of phase contrast fringes while reduce the amplified noise during Fourier regularization.

  18. Functional abdominal pain syndrome treated with Korean medication

    OpenAIRE

    Chang-Gue Son

    2014-01-01

    A 37-year-old female patient with chronic and stubborn abdominal pain had been hospitalized five times in three Western hospitals, but no effects were observed. No abnormalities were found in blood tests, gastrointestinal endoscopy, sonogram, and computed tomography of the abdomen, except mild paralytic ileus. The patient decided to rely on Korean medicine as an inpatient. She was diagnosed with functional abdominal pain syndrome, and her symptom differentiation was the ?Yang deficiency of sp...

  19. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  20. Holography microscopy as an artifact-free alternative to phase-contrast.

    Science.gov (United States)

    Pastorek, Lukáš; Venit, Tomáš; Hozák, Pavel

    2018-02-01

    Artifact-free microscopic images represent a key requirement of multi-parametric image analysis in modern biomedical research. Holography microscopy (HM) is one of the quantitative phase imaging techniques, which has been finding new applications in life science, especially in morphological screening, cell migration, and cancer research. Rather than the classical imaging of absorbing (typically stained) specimens by bright-field microscopy, the information about the light-wave's phase shifts induced by the biological sample is employed for final image reconstruction. In this comparative study, we investigated the usability and the reported advantage of the holography imaging. The claimed halo-free imaging was analyzed compared to the widely used Zernike phase-contrast microscopy. The intensity and phase cross-membrane profiles at the periphery of the cell were quantified. The intensity profile for cells in the phase-contrast images suffers from the significant increase in intensity values around the cell border. On the contrary, no distorted profile is present outside the cell membrane in holography images. The gradual increase in phase shift values is present in the internal part of the cell body projection in holography image. This increase may be related to the increase in the cell internal material according to the dry mass theory. Our experimental data proved the halo-free nature of the holography imaging, which is an important prerequisite of the correct thresholding and cell segmentation, nowadays frequently required in high-content screening and other image-based analysis. Consequently, HM is a method of choice whenever the image analysis relies on the accurate data on cell boundaries.

  1. Abdominal pain – learning when not to intervene!

    Directory of Open Access Journals (Sweden)

    Niranjan Tachamo

    2016-12-01

    Full Text Available Epiploic appendagitis (EA is an uncommon cause of abdominal pain. It is a benign condition but may mimic other serious causes of acute abdomen such as appendicitis, diverticulitis, and gynecological emergency in severe cases. Knowledge of this condition in the differential diagnosis of abdominal pain can save unnecessary hospital admission, antibiotics, and surgery. In this article, we present the case of a 43-year-old female who presented to our hospital with a 2-day history of right lower quadrant abdominal pain and diarrhea. She was diagnosed with EA with computed tomography of abdomen with contrast and was managed conservatively with good outcome.

  2. In-line phase-contrast stereoscopic X-ray imaging for radiological purposes: An initial experimental study

    International Nuclear Information System (INIS)

    Siegbahn, E.A.; Coan, P.; Zhou, S.-A.; Bravin, A.; Brahme, A.

    2011-01-01

    We report results from a pilot study in which the in-line propagation-based phase-contrast imaging technique is combined with the stereoscopic method. Two phantoms were imaged at several sample-detector distances using monochromatic, 30 keV, X-rays. High contrast- and spatial-resolution phase-contrast stereoscopic pairs of X-ray images were constructed using the anaglyph approach and a vivid stereoscopic effect was demonstrated. On the other hand, images of the same phantoms obtained with a shorter sample-to-detector distance, but otherwise the same experimental conditions (i.e. the same X-ray energy and absorbed radiation dose), corresponding to the conventional attenuation-based imaging mode, hardly revealed stereoscopic effects because of the lower image contrast produced. These results have confirmed our hypothesis that stereoscopic X-ray images of samples with objects composed of low-atomic-number elements are considerably improved if phase-contrast imaging is used. It is our belief that the high-resolution phase-contrast stereoscopic method will be a valuable new medical imaging tool for radiologists and that it will be of help to enhance the diagnostic capability in the examination of patients in future clinical practice, even though further efforts will be needed to optimize the system performance.

  3. Design of a compact high-energy setup for x-ray phase-contrast imaging

    Science.gov (United States)

    Schüttler, Markus; Yaroshenko, Andre; Bech, Martin; Potdevin, Guillaume; Malecki, Andreas; Chabior, Michael; Wolf, Johannes; Tapfer, Arne; Meiser, Jan; Kunka, Danays; Amberger, Maximilian; Mohr, Jürgen; Pfeiffer, Franz

    2014-03-01

    The main shortcoming of conventional biomedical x-ray imaging is the weak soft-tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.

  4. A user-friendly LabVIEW software platform for grating based X-ray phase-contrast imaging.

    Science.gov (United States)

    Wang, Shenghao; Han, Huajie; Gao, Kun; Wang, Zhili; Zhang, Can; Yang, Meng; Wu, Zhao; Wu, Ziyu

    2015-01-01

    X-ray phase-contrast imaging can provide greatly improved contrast over conventional absorption-based imaging for weakly absorbing samples, such as biological soft tissues and fibre composites. In this study, we introduced an easy and fast way to develop a user-friendly software platform dedicated to the new grating-based X-ray phase-contrast imaging setup at the National Synchrotron Radiation Laboratory of the University of Science and Technology of China. The control of 21 motorized stages, of a piezoelectric stage and of an X-ray tube are achieved with this software, it also covers image acquisition with a flat panel detector for automatic phase stepping scan. Moreover, a data post-processing module for signals retrieval and other custom features are in principle available. With a seamless integration of all the necessary functions in one software package, this platform greatly facilitate users' activities during experimental runs with this grating based X-ray phase contrast imaging setup.

  5. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  6. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  7. Benign hepatic portal venous gas following blunt abdominal trauma

    International Nuclear Information System (INIS)

    Dill-Mackay, M.J.

    1997-01-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure

  8. Benign hepatic portal venous gas following blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Dill-Mackay, M.J. [Royal Perth Hospital, Perth, WA (Australia). Department of Radiology

    1997-05-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure. 20 refs., 1 tab., 2 figs.

  9. Effects of Contrast Media on Blood Rheology: Comparison in Humans, Pigs, and Sheep

    International Nuclear Information System (INIS)

    Laurent, Alexandre; Durussel, Jean Jacques; Dufaux, Jacques; Penhouet, Laurence; Bailly, Anne Laure; Bonneau, Michel; Merland, Jean Jacques

    1999-01-01

    Purpose: To compare whole blood viscosity and erythrocyte aggregation in humans, pigs, and sheep, before and after adding water-soluble iodinated contrast medium (CM). Methods: Two CMs were studied: iopromide (nonionic) and ioxaglate (ionic). The blood-CM viscosity was measured with a Couette viscometer. Erythrocyte aggregation was measured with an erythroaggregometer. Results: The blood-CM viscosity was increased up to +20% (relative to pure blood) with a CM concentration of 0%-10%. At CM concentrations from 10% to 50%, the viscosity decreased. The disaggregation shear stress was increased (relative to pure blood) at low CM concentration (0%-10%). When the CM concentration increased from 10% to 20%, the disaggregation shear stress was decreased, except with the pig blood-ioxaglate mixture. Conclusion: At low CM concentration the blood viscosity was increased in pig, sheep, and humans and the disaggregation shear stress was increased in pig and humans. The aggregation of sheep blood was too low to be detected by the erythroaggregometer. This rise can be explained by the formation of poorly deformable echinocytes. At higher CM concentration, the viscosity and the disaggregation shear stress decreased in relation to the blood dilution. We conclude that pig blood and sheep blood can both be used to study the effect of CM injection on blood viscosity. Nevertheless, the rheologic behavior of pig blood in terms of erythrocyte aggregation is closer to that of human blood than is sheep blood when mixed with CM. Pigs could thus be more suitable than sheep for in vivo studies of CM miscibility with blood during selective cannulation procedures

  10. Matched filtering Generalized Phase Contrast using binary phase for dynamic spot- and line patterns in biophotonics and structured lighting

    DEFF Research Database (Denmark)

    Bañas, Andrew Rafael; Aabo, Thomas; Palima, Darwin

    2013-01-01

    as a combination of Generalized Phase Contrast and phase-only correlation. Such an analysis makes it convenient to optimize an mGPC system for different setup conditions. Results showing binary-only phase generation of dynamic spot arrays and line patterns are presented. © 201 Optical Society of America...

  11. Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study

    International Nuclear Information System (INIS)

    Karlo, Christoph; Lauber, Arno; Goetti, Robert Paul; Baumueller, Stephan; Stolzmann, Paul; Scheffel, Hans; Desbiolles, Lotus; Marincek, Borut; Leschka, Sebastian; Schmidt, Bernhard; Alkadhi, Hatem

    2011-01-01

    To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). 70 proxies (saline, protein, blood and contrast agent) were placed in unenhanced and contrast-enhanced kidney phantoms. DECT was performed at 80/140 kV with and without tin filtering. Two readers measured the CT attenuation values in all proxies twice. An 80/140 kV ratio was calculated. All intra- and interobserver agreements were excellent (r = 0.93-0.97; p 0.05). The CT attenuation of protein, blood and contrast agent solution differed significantly with tin filtering (p < 0.01-0.05). Significant differences were found between the ratios of protein and blood compared to contrast medium solution (each, p < 0.05) and between the ratios of protein and blood in both phantoms with tin filtering (each, p < 0.05). DECT allows discrimination between a proxy renal lesion containing contrast agent and lesions containing protein and blood through their different attenuation at 80 kV and 140 kV. Further discrimination between protein and blood containing proxies is possible when using a tin filter. (orig.)

  12. Pseudocyst in Omentum caused by Abdominal Tuberculosis : Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Yeon; Kim, Hyun Jin; Park, Soo Youn; Choi, Hyun Joo; Hwang, Seong Su; Cha, Eun Suk; Park, Young Ha [Catholic University of Korea, St.Vincent' s Hospital, Suwon (Korea, Republic of)

    2006-06-15

    A 25-year-old woman presented with abdominal discomfort and weight loss. Sonography demonstrated a well defined, anechoic, cystic mass with posterior acoustic enhancement, internal thin septations, and a peripheral hypoechoic solid portion that had no increased blood flow on Doppler ultrasound. Contrast-enhanced CT revealed a cystic omental mass with internal thin septations and an enhancing solid portion which appeared as the hypoechoic solid portion on ultrasonography. A pathologic specimen demonstrated a pseudocyst containing serous fluid with gelatinous material. The solid component at the peripheral portion of the pseudocyst indicated caseous necrosis with multinucleated giant cells. This histologic finding was consistent with tuberculosis and supported the final diagnosis of omental pseudocyst caused by tuberculous peritonitis. Therefore, intraperitoneal pseudocyst with tuberculosis should be considered in the differential diagnosis of an intraperitoneal cystic mass in a young adult

  13. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  14. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  15. In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.

    Science.gov (United States)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Hirano, Shin-Ichi; Gupta, Rajiv; Ando, Masami

    2015-01-01

    X-ray phase-contrast tomography can significantly increase the contrast-resolution of conventional attenuation-contrast imaging, especially for soft-tissue structures that have very similar attenuation. Just as in attenuation-based tomography, phase contrast tomography requires a linear dependence of aggregate beam direction on the incremental direction alteration caused by individual voxels along the path of the X-ray beam. Dense objects such as calcifications in biological specimens violate this condition. There are extensive beam deflection artefacts in the vicinity of such structures because they result in large distortion of wave front due to the large difference of refractive index; for such large changes in beam direction, the transmittance of the silicon analyzer crystal saturates and is no longer linearly dependent on the angle of refraction. This paper describes a method by which these effects can be overcome and excellent soft-tissue contrast of phase tomography can be preserved in the vicinity of such artefact-producing structures.

  16. Advantages of intermediate X-ray energies in Zernike phase contrast X-ray microscopy.

    Science.gov (United States)

    Wang, Zhili; Gao, Kun; Chen, Jian; Hong, Youli; Ge, Xin; Wang, Dajiang; Pan, Zhiyun; Zhu, Peiping; Yun, Wenbing; Jacobsen, Chris; Wu, Ziyu

    2013-01-01

    Understanding the hierarchical organizations of molecules and organelles within the interior of large eukaryotic cells is a challenge of fundamental interest in cell biology. Light microscopy is a powerful tool for observations of the dynamics of live cells, its resolution attainable is limited and insufficient. While electron microscopy can produce images with astonishing resolution and clarity of ultra-thin (3D images of cryo-preserved cells. The relatively low X-ray energy (3D imaging (e.g., ~1 μm DoF for 20 nm resolution). An X-ray microscope operating at intermediate energy around 2.5 keV using Zernike phase contrast can overcome the above limitations and reduces radiation dose to the specimen. Using a hydrated model cell with an average chemical composition reported in literature, we calculated the image contrast and the radiation dose for absorption and Zernike phase contrast, respectively. The results show that an X-ray microscope operating at ~2.5 keV using Zernike phase contrast offers substantial advantages in terms of specimen size, radiation dose and depth-of-focus. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. High-energy x-ray grating-based phase-contrast radiography of human anatomy

    Science.gov (United States)

    Horn, Florian; Hauke, Christian; Lachner, Sebastian; Ludwig, Veronika; Pelzer, Georg; Rieger, Jens; Schuster, Max; Seifert, Maria; Wandner, Johannes; Wolf, Andreas; Michel, Thilo; Anton, Gisela

    2016-03-01

    X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.

  18. Virtual dissection of Thoropa miliaris tadpole using phase-contrast synchrotron microtomography

    Science.gov (United States)

    Fidalgo, G.; Colaço, M. V.; Nogueira, L. P.; Braz, D.; Silva, H. R.; Colaço, G.; Barroso, R. C.

    2018-05-01

    In this work, in-line phase-contrast synchrotron microtomography was used in order to study the external and internal morphology of Thoropa miliaris tadpoles. Whole-specimens of T. miliaris in larval stages of development 28, 37 and 42, collected in the municipality of Mangaratiba (Rio de Janeiro, Brazil) were used for the study. The samples were scanned in microtomography beamline (IMX) at the Brazilian Synchrotron Light Laboratory (LNLS). The phase-contrast technique allowed us to obtain high quality images which made possible the structures segmentation on the rendered volume by the Avizo graphic image editing software. The combination of high quality images and segmentation process provides adequate visualization of different organs and soft (liver, notochord, brain, crystalline, cartilages) and hard (elements of the bone skeleton) tissues.

  19. X-ray phase contrast imaging of the bone-cartilage interface

    International Nuclear Information System (INIS)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O.; Bunk, O.; Pfeiffer, F.; Farquharson, M.J.; Bradley, D.A.

    2010-01-01

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  20. X-ray phase contrast imaging of the bone-cartilage interface

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Bunk, O. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Pfeiffer, F. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Farquharson, M.J. [Department of Radiography, City University, London EC1V OHB (United Kingdom); Bradley, D.A. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)], E-mail: d.a.bradley@surrey.ac.uk

    2010-04-15

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  1. Effect of inulin supplementation and dietary fat source on performance, blood serum metabolites, liver lipids, abdominal fat deposition, and tissue fatty acid composition in broiler chickens.

    Science.gov (United States)

    Velasco, S; Ortiz, L T; Alzueta, C; Rebolé, A; Treviño, J; Rodríguez, M L

    2010-08-01

    A study was conducted to evaluate the effect of adding inulin to diets containing 2 different types of fat as energy sources on performance, blood serum metabolites, liver lipids, and fatty acids of abdominal adipose tissue and breast and thigh meat. A total of 240 one-day-old female broiler chicks were randomly allocated into 1 of 6 treatments with 8 replicates per treatment and 5 chicks per pen. The experiment consisted of a 3 x 2 factorial arrangement of treatments including 3 concentrations of inulin (0, 5, and 10 g/kg of diet) and 2 types of fat [palm oil (PO) and sunflower oil (SO)] at an inclusion rate of 90 g/kg of diet. The experimental period lasted from 1 to 34 d. Dietary fat type did not affect BW gain but impaired feed conversion (P abdominal fat deposition and serum lipid and glucose concentrations. Triacylglycerol contents in liver were higher in the birds fed PO diets. Dietary fat type also modified fatty acids of abdominal and i.m. fat, resulting in a higher concentration of C16:0 and C18:1n-9 and a lower concentration of C18:2n-6 in the birds fed PO diets. The addition of inulin to diets modified (P = 0.017) BW gain quadratically without affecting feed conversion. Dietary inulin decreased the total lipid concentration in liver (P = 0.003) and that of triacylglycerols and very low density lipoprotein cholesterol (up to 31%) in blood serum compared with the control groups. The polyunsaturated fatty acid:saturated fatty acid ratio increased in abdominal and i.m. fat when inulin was included in the SO-containing diets. The results from the current study suggest that the addition of inulin to broiler diets has a beneficial effect on blood serum lipids by decreasing triacylglyceride concentrations The results also support the use of inulin to increase the capacity of SO for enhancing polyunsaturated fatty acid:saturated fatty acid ratio of i.m. fat in broilers.

  2. Abdominal MRI at 3.0 T: LAVA-Flex compared with conventional fat suppression T1-weighted images.

    Science.gov (United States)

    Li, Xing Hui; Zhu, Jiang; Zhang, Xiao Ming; Ji, Yi Fan; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Zeng, Nan Lin

    2014-07-01

    To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver. © 2013 Wiley Periodicals, Inc.

  3. Five cases of caudal regression with an aberrant abdominal umbilical artery: Further support for a caudal regression-sirenomelia spectrum.

    Science.gov (United States)

    Duesterhoeft, Sara M; Ernst, Linda M; Siebert, Joseph R; Kapur, Raj P

    2007-12-15

    Sirenomelia and caudal regression have sparked centuries of interest and recent debate regarding their classification and pathogenetic relationship. Specific anomalies are common to both conditions, but aside from fusion of the lower extremities, an aberrant abdominal umbilical artery ("persistent vitelline artery") has been invoked as the chief anatomic finding that distinguishes sirenomelia from caudal regression. This observation is important from a pathogenetic viewpoint, in that diversion of blood away from the caudal portion of the embryo through the abdominal umbilical artery ("vascular steal") has been proposed as the primary mechanism leading to sirenomelia. In contrast, caudal regression is hypothesized to arise from primary deficiency of caudal mesoderm. We present five cases of caudal regression that exhibit an aberrant abdominal umbilical artery similar to that typically associated with sirenomelia. Review of the literature identified four similar cases. Collectively, the series lends support for a caudal regression-sirenomelia spectrum with a common pathogenetic basis and suggests that abnormal umbilical arterial anatomy may be the consequence, rather than the cause, of deficient caudal mesoderm. (c) 2007 Wiley-Liss, Inc.

  4. Quantification of signal detection performance degradation induced by phase-retrieval in propagation-based x-ray phase-contrast imaging

    Science.gov (United States)

    Chou, Cheng-Ying; Anastasio, Mark A.

    2016-04-01

    In propagation-based X-ray phase-contrast (PB XPC) imaging, the measured image contains a mixture of absorption- and phase-contrast. To obtain separate images of the projected absorption and phase (i.e., refractive) properties of a sample, phase retrieval methods can be employed. It has been suggested that phase-retrieval can always improve image quality in PB XPC imaging. However, when objective (task-based) measures of image quality are employed, this is not necessarily true and phase retrieval can be detrimental. In this work, signal detection theory is utilized to quantify the performance of a Hotelling observer (HO) for detecting a known signal in a known background. Two cases are considered. In the first case, the HO acts directly on the measured intensity data. In the second case, the HO acts on either the retrieved phase or absorption image. We demonstrate that the performance of the HO is superior when acting on the measured intensity data. The loss of task-specific information induced by phase-retrieval is quantified by computing the efficiency of the HO as the ratio of the test statistic signal-to-noise ratio (SNR) for the two cases. The effect of the system geometry on this efficiency is systematically investigated. Our findings confirm that phase-retrieval can impair signal detection performance in XPC imaging.

  5. Synchrotron-radiation phase-contrast imaging of human stomach and gastric cancer: in vitro studies.

    Science.gov (United States)

    Tang, Lei; Li, Gang; Sun, Ying-Shi; Li, Jie; Zhang, Xiao-Peng

    2012-05-01

    The electron density resolution of synchrotron-radiation phase-contrast imaging (SR-PCI) is 1000 times higher than that of conventional X-ray absorption imaging in light elements, through which high-resolution X-ray imaging of biological soft tissue can be achieved. For biological soft tissue, SR-PCI can give better imaging contrast than conventional X-ray absorption imaging. In this study, human resected stomach and gastric cancer were investigated using in-line holography and diffraction enhanced imaging at beamline 4W1A of the Beijing Synchrotron Radiation Facility. It was possible to depict gastric pits, measuring 50-70 µm, gastric grooves and tiny blood vessels in the submucosa layer by SR-PCI. The fine structure of a cancerous ulcer was displayed clearly on imaging the mucosa. The delamination of the gastric wall and infiltration of cancer in the submucosa layer were also demonstrated on cross-sectional imaging. In conclusion, SR-PCI can demonstrate the subtle structures of stomach and gastric cancer that cannot be detected by conventional X-ray absorption imaging, which prompt the X-ray diagnosis of gastric disease to the level of the gastric pit, and has the potential to provide new methods for the imageology of gastric cancer.

  6. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    International Nuclear Information System (INIS)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs

  7. Abdominal obesity is strongly associated to blood pressure in young Mexicans.

    Science.gov (United States)

    Urquidez Romero, Rene; Murguía Romero, Miguel; Esparza Romero, Julián; Díaz Torres, Beatriz Araceli; Rodríguez Tadeo, Alejandra; Medrano Donlucas, Gabriel; Ramos Jiménez, Arnulfo; Wall Medrano, Abraham; Gallardo Ortíz, Itzell A; Tapia Pancardo, Diana C Tapia-Pancardo C; Méndez Cruz, A René; Jiménez Flores, J Rafael; Villalobos Molina, Rafael

    2017-03-30

    The objective of this study was to determine associations between abdominal obesity (AOb) and the other components of metabolic syndrome (MetS) in young Mexicans in a cross-sectional survey completed during a 4 year period. This cross-sectional study reports on components and prevalence of MetS by using Alberti et al. (16) criteria, as well as association between AOb and elevated blood pressure (BP) of 2,993 Mexican university students, ages 17 to 25 years (66% women) from central and northern Mexico, over a 4-year survey (2010-2013). The most prevalent MetS components in the total sample were low HDL-C concentration (43.6%) and AOb (41.1%). MetS prevalence was 11.8%, more men than women were classified with MetS (14.3% vs. 10.5%, p < 0.01). BP was the MetS component with the lowest prevalence (8.6%). A strong association between AOb and altered BP with in both men and women was found (OR 4.3, IC95% 2.5-7.4). Even BP was the component with the lowest prevalence, AOb was more strongly associated with it. This fact, could explain the prevalence of hypertension among young Mexican adults.

  8. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  9. A phase contrast imaging system for TEXT-U

    International Nuclear Information System (INIS)

    Chatterjee, R.; Hallock, G.A.; Gartman, M.L.

    1994-01-01

    A diagnostic to study plasma density fluctuations, Phase Contrast Imaging (PCI) has been developed for the Texas Experimental Tokamak-Upgrade. The diagnostic has a sensitivity of about 10 -4 n e0 and is capable of detecting a wide range of wavenumbers (0.5 cm -1 - 12 cm -1 ) with a bandwidth of 500 Khz. The design of the diagnostic, some results of acoustic calibration tests and preliminary results of simulation of expected spectra are presented

  10. Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows.

    Science.gov (United States)

    Lee, Sang Joon; Park, Han Wook; Jung, Sung Yong

    2014-09-01

    X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.

  11. Longitudinal changes in abdominal fat distribution with menopause.

    Science.gov (United States)

    Franklin, Ruth M; Ploutz-Snyder, Lori; Kanaley, Jill A

    2009-03-01

    Increases in abdominal fat have been reported with menopause, but the impact of menopause on abdominal fat distribution (visceral vs subcutaneous) is still unclear. The objective of the study was to determine if abdominal fat content (volume) or distribution is altered with menopause. Magnetic resonance imaging was used to quantify total abdominal, subcutaneous, and visceral fat in 8 healthy women, both in the premenopausal state and 8 years later in the postmenopausal state. Physical activity (PA) and blood lipids were also measured. Body weight and waist circumference did not change with menopause (pre- vs postmenopause: body weight, 63.2 +/- 3.1 vs 63.9 +/- 2.5 kg; waist circumference, 92.1 +/- 4.6 vs 93.4 +/- 3.7 cm); however, total abdominal fat, subcutaneous fat, and visceral fat all significantly (P fat distribution was not significantly different after menopause (pre- vs postmenopause: subcutaneous, 73% +/- 3% vs 71% +/- 3%; visceral, 26% +/- 3% vs 28% +/- 3%). Lean mass, fat mass, and PA, along with total cholesterol and triglyceride levels, did not change with menopause. High-density lipoprotein and low-density lipoprotein both increased (P abdominal fat content increased with menopause despite no change in PA, body weight, or waist circumference; however, menopause did not affect the relative abdominal fat distribution in these women.

  12. Assessment of the effects of different sample perfusion procedures on phase-contrast tomographic images of mouse spinal cord

    Science.gov (United States)

    Stefanutti, E.; Sierra, A.; Miocchi, P.; Massimi, L.; Brun, F.; Maugeri, L.; Bukreeva, I.; Nurmi, A.; Begani Provinciali, G.; Tromba, G.; Gröhn, O.; Giove, F.; Cedola, A.; Fratini, M.

    2018-03-01

    Synchrotron X-ray Phase Contrast micro-Tomography (SXrPCμT) is a powerful tool in the investigation of biological tissues, including the central nervous system (CNS), and it allows to simultaneously detect the vascular and neuronal network avoiding contrast agents or destructive sample preparations. However, specific sample preparation procedures aimed to optimize the achievable contrast- and signal-to-noise ratio (CNR and SNR, respectively) are required. Here we report and discuss the effects of perfusion with two different fixative agents (ethanol and paraformaldehyde) and with a widely used contrast medium (MICROFIL®) on mouse spinal cord. As a main result, we found that ethanol enhances contrast at the grey/white matter interface and increases the contrast in correspondence of vascular features and fibres, thus providing an adequate spatial resolution to visualise the vascular network at the microscale. On the other hand, ethanol is known to induce tissue dehydration, likely reducing cell dimensions below the spatial resolution limit imposed by the experimental technique. Nonetheless, neurons remain well visible using either perfused paraformaldehyde or MICROFIL® compound, as these latter media do not affect tissues with dehydration effects. Paraformaldehyde appears as the best compromise: it is not a contrast agent, like MICROFIL®, but it is less invasive than ethanol and permits to visualise well both cells and blood vessels. However, a quantitative estimation of the relative grey matter volume of each sample has led us to conclude that no significant alterations in the grey matter extension compared to the white matter occur as a consequence of the perfusion procedures tested in this study.

  13. Preliminary research on dual-energy X-ray phase-contrast imaging

    Science.gov (United States)

    Han, Hua-Jie; Wang, Sheng-Hao; Gao, Kun; Wang, Zhi-Li; Zhang, Can; Yang, Meng; Zhang, Kai; Zhu, Pei-Ping

    2016-04-01

    Dual-energy X-ray absorptiometry (DEXA) has been widely applied to measure the bone mineral density (BMD) and soft-tissue composition of the human body. However, the use of DEXA is greatly limited for low-Z materials such as soft tissues due to their weak absorption, while X-ray phase-contrast imaging (XPCI) shows significantly improved contrast in comparison with the conventional standard absorption-based X-ray imaging for soft tissues. In this paper, we propose a novel X-ray phase-contrast method to measure the area density of low-Z materials, including a single-energy method and a dual-energy method. The single-energy method is for the area density calculation of one low-Z material, while the dual-energy method aims to calculate the area densities of two low-Z materials simultaneously. Comparing the experimental and simulation results with the theoretical ones, the new method proves to have the potential to replace DEXA in area density measurement. The new method sets the prerequisites for a future precise and low-dose area density calculation method for low-Z materials. Supported by Major State Basic Research Development Program (2012CB825800), Science Fund for Creative Research Groups (11321503) and National Natural Science Foundation of China (11179004, 10979055, 11205189, 11205157)

  14. Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output.

    Science.gov (United States)

    Masuda, Takanori; Nakaura, Takeshi; Funama, Yoshinori; Higaki, Toru; Kiguchi, Masao; Imada, Naoyuki; Sato, Tomoyasu; Awai, Kazuo

    We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning. This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement. Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P linear regression analysis showed that only the TBW and CO were of independent predictive value (P linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.

  15. Effect of streptozotocin-induced diabetes on myocardial blood flow reserve assessed by myocardial contrast echocardiography in rats

    Directory of Open Access Journals (Sweden)

    Weytjens Caroline

    2008-09-01

    Full Text Available Abstract The role of structural and functional abnormalities of small vessels in diabetes cardiomyopathy remains unclear. Myocardial contrast echocardiography allows the quantification of myocardial blood flow at rest and during dipyridamole infusion. The aim of the study was to determine the myocardial blood flow reserve in normal rats compared with Streptozotocin-induced diabetic rats using contrast echocardiography. Methods We prospectively studied 40 Wistar rats. Diabetes was induced by intravenous streptozotocin in 20 rats. All rats underwent baseline and stress (dipyridamole: 20 mg/kg high power intermittent imaging in short axis view under anaesthesia baseline and after six months. Myocardial blood flow was determined and compared at rest and after dipyridamole in both populations. The myocardial blood flow reserve was calculated and compared in the 2 groups. Parameters of left ventricular function were determined from the M-mode tracings and histological examination was performed in all rats at the end of the study. Results At six months, myocardial blood flow reserve was significantly lower in diabetic rats compared to controls (3.09 ± 0.98 vs. 1.28 ± 0.67 ml min-1 g-1; p Conclusion In this animal study, diabetes induced a functional alteration of the coronary microcirculation, as demonstrated by contrast echocardiography, a decrease in capillary density and of the cardiac systolic function. These findings may offer new insights into the underlying mechanisms of diabetes cardiomyopathy.

  16. Blood vessel-based liver segmentation through the portal phase of a CT dataset

    Science.gov (United States)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Moriyama, Noriyuki; Utsunomiya, Toru; Shimada, Mitsuo

    2013-02-01

    Blood vessels are dispersed throughout the human body organs and carry unique information for each person. This information can be used to delineate organ boundaries. The proposed method relies on abdominal blood vessels (ABV) to segment the liver considering the potential presence of tumors through the portal phase of a CT dataset. ABV are extracted and classified into hepatic (HBV) and nonhepatic (non-HBV) with a small number of interactions. HBV and non-HBV are used to guide an automatic segmentation of the liver. HBV are used to individually segment the core region of the liver. This region and non-HBV are used to construct a boundary surface between the liver and other organs to separate them. The core region is classified based on extracted posterior distributions of its histogram into low intensity tumor (LIT) and non-LIT core regions. Non-LIT case includes normal part of liver, HBV, and high intensity tumors if exist. Each core region is extended based on its corresponding posterior distribution. Extension is completed when it reaches either a variation in intensity or the constructed boundary surface. The method was applied to 80 datasets (30 Medical Image Computing and Computer Assisted Intervention (MICCAI) and 50 non-MICCAI data) including 60 datasets with tumors. Our results for the MICCAI-test data were evaluated by sliver07 [1] with an overall score of 79.7, which ranks seventh best on the site (December 2013). This approach seems a promising method for extraction of liver volumetry of various shapes and sizes and low intensity hepatic tumors.

  17. New generation quantitative x-ray microscopy encompassing phase-contrast

    International Nuclear Information System (INIS)

    Wilkins, S.W.; Mayo, S.C.; Gureyev, T.E.; Miller, P.R.; Pogany, A.; Stevenson, A.W.; Gao, D.; Davis, T.J.; Parry, D.J.; Paganin, D.

    2000-01-01

    Full text: We briefly outline a new approach to X-ray ultramicroscopy using projection imaging in a scanning electron microscope (SEM). Compared to earlier approaches, the new approach offers spatial resolution of ≤0.1 micron and includes novel features such as: i) phase contrast to give additional sample information over a wide energy range, rapid phase/amplitude extraction algorithms to enable new real-time modes of microscopic imaging widespread applications are envisaged to fields such as materials science, biomedical research, and microelectronics device inspection. Some illustrative examples are presented. The quantitative methods described here are also very relevant to X-ray projection microscopy using synchrotron sources

  18. Choice and technique of negative contrast in double contrast roentgenography of the stomach

    International Nuclear Information System (INIS)

    Pomakov, P.; Tomov, A.; Popsavov, P.; Tirolska, M.

    1993-01-01

    A comparative study of 8 negative contrast media is performed in 720 patients undergoing double-contrast abdominal biomedical radiography. The following preparations and methods are compared: Unibarit (Roelm, Pharma), CO 2 granulate (Nicholas), Sandosten Calcium + Calcium gluconicum (Sandoz, Pharmachim), Kalinor (Nordmark), dust variation of p. Rivieri, conducted aerophagy, stomach-tube, 'Echo'-lemonade. The average size of the gas bubble of the fornix (cm 2 ), the average volume of the gas collection (ml) and the relationship between the area of the negative contrast image (cm 2 ) and the volume of the gas (ml) is given. Some possibilities for production of domestic negative contrast media are also discussed. 2 tabs., 18 refs. (orig.)

  19. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  20. Implementation of neutron phase contrast imaging at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Klaus

    2008-11-12

    At ANTARES, the beam line for neutron imaging at the Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) in Garching, the option to do phase contrast imaging besides conventional absorption based neutron imaging was implemented and successfully used for the non-destructive testing of various types of objects. The used propagation-based technique is based on the interference of neutron waves in the detector plane that were differently strong diffracted by the sample. A comparison with other phase-sensitive neutron imaging techniques highlights assets and drawbacks of the different methods. In preliminary measurements at ANTARES and the spallation source SINQ at PSI in Villigen, the influence of the beam geometry, the neutron spectrum and the detector on the quality of the phase contrast measurements were investigated systematically. It was demonstrated that gamma radiation and epithermal neutrons in the beam contribute severely to background noise in measurements, which motivated the installation of a remotely controlled filter wheel for a quick and precise positioning of different crystal filters in the beam. By the installation of a similar aperture wheel, a quick change between eight different beam geometries was made possible. Besides pinhole and slit apertures, coded apertures based on non redundant arrays were investigated. The possibilities, which arise by the exploitation of the real part of the refractive index in neutron imaging, were demonstrated in experiments with especially designed test samples and in measurements with ordinary, industrial components. (orig.)

  1. Implementation of neutron phase contrast imaging at FRM-II

    International Nuclear Information System (INIS)

    Lorenz, Klaus

    2008-01-01

    At ANTARES, the beam line for neutron imaging at the Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) in Garching, the option to do phase contrast imaging besides conventional absorption based neutron imaging was implemented and successfully used for the non-destructive testing of various types of objects. The used propagation-based technique is based on the interference of neutron waves in the detector plane that were differently strong diffracted by the sample. A comparison with other phase-sensitive neutron imaging techniques highlights assets and drawbacks of the different methods. In preliminary measurements at ANTARES and the spallation source SINQ at PSI in Villigen, the influence of the beam geometry, the neutron spectrum and the detector on the quality of the phase contrast measurements were investigated systematically. It was demonstrated that gamma radiation and epithermal neutrons in the beam contribute severely to background noise in measurements, which motivated the installation of a remotely controlled filter wheel for a quick and precise positioning of different crystal filters in the beam. By the installation of a similar aperture wheel, a quick change between eight different beam geometries was made possible. Besides pinhole and slit apertures, coded apertures based on non redundant arrays were investigated. The possibilities, which arise by the exploitation of the real part of the refractive index in neutron imaging, were demonstrated in experiments with especially designed test samples and in measurements with ordinary, industrial components. (orig.)

  2. Holography microscopy as an artifact-free alternative to phase-contrast

    Czech Academy of Sciences Publication Activity Database

    Pastorek, Lukáš; Venit, Tomáš; Hozák, Pavel

    2018-01-01

    Roč. 149, č. 2 (2018), s. 179-186 ISSN 0948-6143 R&D Projects: GA MŠk(CZ) LM2015062 Institutional support: RVO:68378050 Keywords : Holography microscopy * Phase-contrast * Halo effect Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Cell biology Impact factor: 2.553, year: 2016

  3. Effect of Saline Pushing after Contrast Material Injection in Abdominal Multidetector Computed Tomography with the Use of Different Iodine Concentrations

    International Nuclear Information System (INIS)

    Tatsugami, F.; Matsuki, M.; Kani, H.; Tanikake, M.; Miyao, M.; Yoshikawa, S.; Narabayashi, I.

    2006-01-01

    Purpose: To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration. Material and Methods: 120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well. Results: Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different. Conclusion: The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography

  4. Accelerated 4D phase contrast MRI in skeletal muscle contraction.

    Science.gov (United States)

    Mazzoli, Valentina; Gottwald, Lukas M; Peper, Eva S; Froeling, Martijn; Coolen, Bram F; Verdonschot, Nico; Sprengers, Andre M; van Ooij, Pim; Strijkers, Gustav J; Nederveen, Aart J

    2018-03-05

    3D time-resolved (4D) phase contrast MRI can be used to study muscle contraction. However, 3D coverage with sufficient spatiotemporal resolution can only be achieved by interleaved acquisitions during many repetitions of the motion task, resulting in long scan times. The aim of this study was to develop a compressed sensing accelerated 4D phase contrast MRI technique for quantification of velocities and strain rate of the muscles in the lower leg during active plantarflexion/dorsiflexion. Nine healthy volunteers were scanned during active dorsiflexion/plantarflexion task. For each volunteer, we acquired a reference scan, as well as 4 different accelerated scans (k-space undersampling factors: 3.14X, 4.09X, 4.89X, and 6.41X) obtained using Cartesian Poisson disk undersampling schemes. The data was reconstructed using a compressed sensing pipeline. For each scan, velocity and strain rate values were quantified in the gastrocnemius lateralis, gastrocnemius medialis, tibialis anterior, and soleus. No significant differences in velocity values were observed as a function acceleration factor in the investigated muscles. The strain rate calculation resulted in one positive (s + ) and one negative (s - ) eigenvalue, whereas the third eigenvalue (s 3 ) was consistently 0 for all the acquisitions. No significant differences were observed for the strain rate eigenvalues as a function of acceleration factor. Data undersampling combined with compressed sensing reconstruction allowed obtainment of time-resolved phase contrast acquisitions with 3D coverage and quantitative information comparable to the reference scan. The 3D sensitivity of the method can help in understanding the connection between muscle architecture and muscle function in future studies. © 2018 International Society for Magnetic Resonance in Medicine.

  5. Abdominal Obesity in German Adolescents Defined by Waist-to-Height Ratio and Its Association to Elevated Blood Pressure: The KiGGS Study

    Directory of Open Access Journals (Sweden)

    Katrin Kromeyer-Hauschild

    2013-04-01

    Full Text Available Objective: The aim of this study was to compare the fixed 0.5 cut-off and the age- and sex-specific 90th percentile (P90 for waist-to-height ratio (WHtR in German adolescents with respect to the prevalence of abdominal obesity and to compare the screening ability of WHtR and BMI to identify hypertensive blood pressure (BP values. Methods: Between 2003 and 2006, the German Health Interview and Examination Survey for Children and Adolescents (KiGGS was carried out including 3,492 boys and 3,321 girls aged 11-17 years. Abdominal obesity was assessed by two WHtR cut-points (P90; 0.5. Hypertensive BP was defined as BP exceeding age-, sex- and height-specific 95th percentiles or the adult threshold for hypertension (140/90 mm Hg. Results: Agreement between the WHtR cut-offs was very good (Kappa 0.89 for boys; 0.81 for girls, and the prevalence of abdominal obesity was slightly higher using P90 (boys 12.0%; girls 11.3% compared to 0.5 (boys 10.7%; girls 8.0%. WHtR and BMI-for-age had equivalent ability to discriminate hypertensive BP (ROC-AUC Conclusion: The fixed 0.5 WHtR cut-off can be used in German adolescents to characterize abdominal obesity. However, WHtR is not suitable as a screening tool for hypertensive BP in adolescents.

  6. A reconstruction method for cone-beam differential x-ray phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Velroyen, Astrid; Tan, Renbo; Zhang, Junwei; Chen, Liyuan; Tapfer, Arne; Bech, Martin; Pfeiffer, Franz

    2012-09-10

    Most existing differential phase-contrast computed tomography (DPC-CT) approaches are based on three kinds of scanning geometries, described by parallel-beam, fan-beam and cone-beam. Due to the potential of compact imaging systems with magnified spatial resolution, cone-beam DPC-CT has attracted significant interest. In this paper, we report a reconstruction method based on a back-projection filtration (BPF) algorithm for cone-beam DPC-CT. Due to the differential nature of phase contrast projections, the algorithm restrains from differentiation of the projection data prior to back-projection, unlike BPF algorithms commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a micro-focus x-ray tube source. Moreover, the numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated cone-beam datasets. We believe that this feature is of particular interest for future medical cone-beam phase-contrast CT imaging applications.

  7. Quantitative differential phase contrast imaging at high resolution with radially asymmetric illumination.

    Science.gov (United States)

    Lin, Yu-Zi; Huang, Kuang-Yuh; Luo, Yuan

    2018-06-15

    Half-circle illumination-based differential phase contrast (DPC) microscopy has been utilized to recover phase images through a pair of images along multiple axes. Recently, the half-circle based DPC using 12-axis measurements significantly provides a circularly symmetric phase transfer function to improve accuracy for more stable phase recovery. Instead of using half-circle-based DPC, we propose a new scheme of DPC under radially asymmetric illumination to achieve circularly symmetric phase transfer function and enhance the accuracy of phase recovery in a more stable and efficient fashion. We present the design, implementation, and experimental image data demonstrating the ability of our method to obtain quantitative phase images of microspheres, as well as live fibroblast cell samples.

  8. Quantitative hard x-ray phase contrast imaging of micropipes in SiC

    International Nuclear Information System (INIS)

    Kohn, V. G.; Argunova, T. S.; Je, J. H.

    2013-01-01

    Peculiarities of quantitative hard x-ray phase contrast imaging of micropipes in SiC are discussed. The micropipe is assumed as a hollow cylinder with an elliptical cross section. The major and minor diameters can be restored using the least square fitting procedure by comparing the experimental data, i.e. the profile across the micropipe axis, with those calculated based on phase contrast theory. It is shown that one projection image gives an information which does not allow a complete determination of the elliptical cross section, if an orientation of micropipe is not known. Another problem is a weak accuracy in estimating the diameters, partly because of using pink synchrotron radiation, which is necessary because a monochromatic beam intensity is not sufficient to reveal the weak contrast from a very small object. The general problems of accuracy in estimating the two diameters using the least square procedure are discussed. Two experimental examples are considered to demonstrate small as well as modest accuracies in estimating the diameters

  9. Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI.

    Science.gov (United States)

    Dyverfeldt, Petter; Sigfridsson, Andreas; Kvitting, John-Peder Escobar; Ebbers, Tino

    2006-10-01

    Turbulent flow, characterized by velocity fluctuations, is a contributing factor to the pathogenesis of several cardiovascular diseases. A clinical noninvasive tool for assessing turbulence is lacking, however. It is well known that the occurrence of multiple spin velocities within a voxel during the influence of a magnetic gradient moment causes signal loss in phase-contrast magnetic resonance imaging (PC-MRI). In this paper a mathematical derivation of an expression for computing the standard deviation (SD) of the blood flow velocity distribution within a voxel is presented. The SD is obtained from the magnitude of PC-MRI signals acquired with different first gradient moments. By exploiting the relation between the SD and turbulence intensity (TI), this method allows for quantitative studies of turbulence. For validation, the TI in an in vitro flow phantom was quantified, and the results compared favorably with previously published laser Doppler anemometry (LDA) results. This method has the potential to become an important tool for the noninvasive assessment of turbulence in the arterial tree.

  10. Interaction of dispersed cubic phases with blood components

    DEFF Research Database (Denmark)

    Bode, J C; Kuntsche, Judith; Funari, S S

    2013-01-01

    The interaction of aqueous nanoparticle dispersions, e.g. based on monoolein/poloxamer 407, with blood components is an important topic concerning especially the parenteral way of administration. Therefore, the influence of human and porcine plasma on dispersed cubic phases was investigated. Part...... activity of cubic phases based on monoolein and poloxamer 188, on soy phosphatidylcholine, glycerol dioleate and polysorbate 80 or the parenteral fat emulsion Lipofundin MCT 20%....

  11. Phase-contrast versus off-axis illumination: is a more complex microscope always more powerful?

    Czech Academy of Sciences Publication Activity Database

    Hostounský, Z.; Pelc, Radek

    2007-01-01

    Roč. 31, č. 2 (2007), s. 232-235 ISSN 1043-4046 Institutional research plan: CEZ:AV0Z50200510 Keywords : microscope * relief contrast * phase contrast Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.984, year: 2007

  12. Cerebral blood flow and brain atrophy correlated by xenon contrast CT scanning

    International Nuclear Information System (INIS)

    Kitagawa, Y.; Meyer, J.S.; Tanahashi, N.; Rogers, R.L.; Tachibana, H.; Kandula, P.; Dowell, R.E.; Mortel, K.F.

    1985-01-01

    Correlations between cerebral blood flow (CBF) measured during stable xenon contrast CT scanning and standard CT indices of brain atrophy were investigated in the patients with senile dementia of Alzheimer type, multi-infarct dementia and idiopathic Parkinson's disease. Compared to age-matched normal volunteers, significant correlations were found in patients with idiopathic Parkinson's disease between cortical and subcortical gray matter blood flow and brain atrophy estimated by the ventricular body ratio, and mild to moderate brain atrophy were correlated with stepwise CBF reductions. However, in patients with senile dementia of Alzheimer type and multi-infarct dementia, brain atrophy was not associated with stepwise CBF reductions. Overall correlations between brain atrophy and reduced CBF were weak. Mild degrees of brain atrophy are not always associated with reduced CBF

  13. Cost reduction in abdominal CT by weight-adjusted dose.

    Science.gov (United States)

    Arana, Estanislao; Martí-Bonmatí, Luis; Tobarra, Eva; Sierra, Consuelo

    2009-06-01

    To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT). A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22-67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified (81 kg). Aortic attenuation was significantly superior (p61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p80 kg, there was an over cost of euro 10.7 per patient. An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of euro 1.34 per patient.

  14. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  15. Generalized Phase contrast and matched filtering for speckle‐free patterned illumination

    DEFF Research Database (Denmark)

    Palima, Darwin; Bañas, Andrew Rafael; Villangca, Mark Jayson

    2013-01-01

    Generalized Phase Contrast (GPC) and matched‐filtering GPC use tandem diffractive phase elements on Fourier‐conjugate planes of a 4f optical processor to efficiently reshape incident light into a pattern that resembles the input phase modulation pattern. The synthesized patterns are inherently...... to optically trap and mechanically manipulate microparticles, GPC has also been applied for laser beamshaping, optical phase cryptography, and greyscale image projection. Recent reports from our collaborators highlight that GPC‐based spatial lightshaping, when combined with temporal focusing and multiphoton...... excitation, exhibits some robustness against light scattering and, hence, makes a promising tool for spatially precise targeting of deeper subsurface neurons using minimally speckled patterned illumination for multiphoton excitation....

  16. Full-term extrauterine abdominal pregnancy: a case report

    Directory of Open Access Journals (Sweden)

    Babgi Reem

    2011-10-01

    Full Text Available Abstract Introduction Extrauterine abdominal pregnancy is extremely rare and is frequently missed during antenatal care. This is a report of a full-term extrauterine abdominal pregnancy in a primigravida who likely had a ruptured ectopic pregnancy with secondary implantation and subsequently delivered a healthy baby. Case presentation A 23-year-old, Middle Eastern, primigravida presented at 14 weeks gestation with intermittent suprapubic pain and dysuria. An abdominal ultrasound examination showed a single viable fetus with free fluid in her abdomen. A follow-up examination at term showed a breech presentation and the possibility of a bicornute uterus with the fetus present in the left horn of her uterus. Our patient underwent Cesarean delivery under general anesthesia and was found to have a small intact uterus with the fetus lying in her abdomen and surrounded by an amniotic fluid-filled sac. The baby was extracted uneventfully, but the placenta was implanted in the left broad ligament and its removal resulted in massive intraoperative bleeding that necessitated blood and blood products transfusion and the administration of Factor VII to control the bleeding. Both the mother and newborn were discharged home in good condition. Conclusions An extrauterine abdominal pregnancy secondary to a ruptured ectopic pregnancy with secondary implantation could be missed during antenatal care and continue to term with good maternal and fetal outcome. An advanced extrauterine pregnancy should not result in the automatic termination of the pregnancy.

  17. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction.

    Science.gov (United States)

    Hwang, Shin Hye; You, Je Sung; Song, Mi Kyong; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun

    2015-04-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. • There was no difference in diagnostic performance of HVP CT and multiphasic CT. • The diagnostic confidence level was improved after review of the LAP images. • HVP CT can achieve diagnostic performance similar to that of multiphasic CT, while minimizing radiation.

  18. Gastric stromal tumor: two-phase dynamic CT findings with water as oral contrast agents

    International Nuclear Information System (INIS)

    Lee, Se Hyo; Cho, June Sik; Shin, Kyung Sook; Jeong, Ki Ho; Park, Jin Yong; Yu, Ho Jun; Kim, Young Min; Jeon, Kwang Jin

    2000-01-01

    To evaluate two-phase dynamic CT with water as oral contrast agents in the CT diagnosis of gastric stromal tumors. We retrospectively reviewed the CT findings in 21 patients with pathologically proven gastric stromal tumors. Six were found to be benign, twelve were malignant, and there were three cases of STUMP (stromal tumor uncertain malignant potential). Two-phase dynamic CT scans with water as oral contrast agents were obtained 60-70 secs (portal phase) and 3 mins (equilibrium phase) after the start of IV contrast administration. We determined the size, growth pattern, and enhancement pattern of the tumors and overlying mucosa, the presence or absence of ulceration and necrosis, tumor extent, and lymph nod and distant metastasis. The CT and pathologic findings were correlated. All six benign tumors and three STUMP were less than 5.5 cm in size, and during the portal phase showed round endogastric masses with highly enhanced, intact overlying mucosa. Twelve malignant tumors were 4.5-15.5 cm in size (mean, 11.5 cm); an endogastric mass was seen in three cases, an exogastric mass in one, and a mixed pattern in eight. On portal phase images the tumors were not significantly enhanced, but highly enhanced feeding vessels were noted in five larger tumors (greater than 10 cm). All 12 malignant tumors showed ulceration and necrosis, and interruption of overlying mucosa was clearly seen during the portal phase. We were readily able to evaluate tumor extent during this phase, and in ten malignant tumors there was no invasion of adjacent organs. Seven malignant tumors showed air density within their necrotic portion (p less than 0.05). On equilibrium phase images, all malignant tumors showed heterogeneous enhancement due to necrosis, and poorly enhanced overlying mucosa. Dynamic CT during the portal phase with water as oral contrast agents was useful for depicting the submucosal origin of gastric stromal tumors and for evaluating the extent of malignant stromal tumors. Our

  19. In-vivo brain blood flow imaging based on laser speckle contrast imaging and synchrotron radiation microangiography

    International Nuclear Information System (INIS)

    Miao, Peng; Feng, Shihan; Zhang, Qi; Lin, Xiaojie; Xie, Bohua; Liu, Chenwei; Yang, Guo-Yuan

    2014-01-01

    Abstract In-vivo imaging of blood flow in the cortex and sub-cortex is still a challenge in biological and pathological studies of cerebral vascular diseases. Laser speckle contrast imaging (LSCI) only provides cortex blood flow information. Traditional synchrotron radiation micro-angiography (SRA) provides sub-cortical vasculature information with high resolution. In this study, a bolus front-tracking method was developed to extract blood flow information based on SRA. Combining LSCI and SRA, arterial blood flow in the ipsilateral cortex and sub-cortex was monitored after experimental intracerebral hemorrhage of mice. At 72 h after injury, a significant blood flow increase was observed in the lenticulostriate artery along with blood flow decrease in cortical branches of the middle cerebral artery. This combined strategy provides a new approach for the investigation of brain vasculature and blood flow changes in preclinical studies. (paper)

  20. Trans-abdominal ultrasound evaluation of high-intensity focused ultrasound treatment of uterine leiomyoma

    International Nuclear Information System (INIS)

    Miao Wei; Huang Jin; Wang Junhua; Wang Yuling

    2010-01-01

    Objective: To determine the value of dynamic trans-abdominal ultrasound after high-intensity focused ultrasound (HIFU) treatment of uterine leiomyomas. Methods: The trans-abdominal ultrasound images of 63 patients before and after HIFU treatment of uterine leiomyomas were compared. Results: The volume and blood flow of leiomyomas were reduced after the HIFU treatment. Conclusion: Trans-abdominal ultrasound is a valuable method for evaluating the results of HIFU treatment of uterine leiomyomas. (authors)

  1. Active Detoxification in the Treatment of Abdominal Sepsis

    Directory of Open Access Journals (Sweden)

    O. M. Shevtsova

    2009-01-01

    Full Text Available Objective: to evaluate the efficiency of extracorporeal detoxification techniques in patients with abdominal sepsis. Subjects and methods. Three hundred and seventy-nine patients with acute generalized peritonitis were examined. Extracorporeal detoxifying techniques were used during conventional therapy in Group 1 (n=319; the other patients received only traditional therapy (a control group. The time course of changes in the parameters of toxemia, a hemostasiogram, and an immunogram were examined. Results. The study indicated significantly reduced endotoxemia and better blood aggregation resulting from the use of plasmapheresis, cryoplasmasorption, and plasmasorption, as well as stimulated immunity when the above techniques were combined with autoblood photomodification and extracorporeal immunopharmacotherapy in patients with abdominal sepsis. In severe abdominal sepsis and infectious-toxic shock, there was regression of multiple organ dysfunction and lower mortality when venovenous hemofiltration was applied. Conclusion. A differential approach to using active detoxifying techniques is needed, by taking into account the severity of the disease. Key words: abdominal sepsis, detoxifying techniques.

  2. Zernike phase-contrast electron cryotomography applied to marine cyanobacteria infected with cyanophages.

    Science.gov (United States)

    Dai, Wei; Fu, Caroline; Khant, Htet A; Ludtke, Steven J; Schmid, Michael F; Chiu, Wah

    2014-11-01

    Advances in electron cryotomography have provided new opportunities to visualize the internal 3D structures of a bacterium. An electron microscope equipped with Zernike phase-contrast optics produces images with markedly increased contrast compared with images obtained by conventional electron microscopy. Here we describe a protocol to apply Zernike phase plate technology for acquiring electron tomographic tilt series of cyanophage-infected cyanobacterial cells embedded in ice, without staining or chemical fixation. We detail the procedures for aligning and assessing phase plates for data collection, and methods for obtaining 3D structures of cyanophage assembly intermediates in the host by subtomogram alignment, classification and averaging. Acquiring three or four tomographic tilt series takes ∼12 h on a JEM2200FS electron microscope. We expect this time requirement to decrease substantially as the technique matures. The time required for annotation and subtomogram averaging varies widely depending on the project goals and data volume.

  3. Interactive thresholded volumetry of abdominal fat using breath-hold T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wittsack, H.J.; Cohnen, M.; Jung, G.; Moedder, U.; Poll, L.; Kapitza, C.; Heinemann, L.

    2006-01-01

    Purpose: development of a feasible and reliable method for determining abdominal fat using breath-hold T1-weighted magnetic resonance imaging. Materials and methods: the high image contrast of T1-weighted gradient echo MR sequences makes it possible to differentiate between abdominal fat and non-fat tissue. To obtain a high signal-to-noise ratio, the measurements are usually performed using phased array surface coils. Inhomogeneity of the coil sensitivity leads to inhomogeneity of the image intensities. Therefore, to examine the volume of abdominal fat, an automatic algorithm for intensity correction must be implemented. The analysis of the image histogram results in a threshold to separate fat from other tissue. Automatic segmentation using this threshold results directly in the fat volumes. The separation of intraabdominal and subcutaneous fat is performed by interactive selection in a last step. Results: the described correction of inhomogeneity allows for the segmentation of the images using a global threshold. The use of semiautomatic interactive volumetry makes the analysis more subjective. The variance of volumetry between observers was 4.6%. The mean time for image analysis of a T1-weighted investigation lasted less than 6 minutes. Conclusion: the described method facilitates reliable determination of abdominal fat within a reasonable period of time. Using breath-hold MR sequences, the time of examination is less than 5 minutes per patient. (orig.)

  4. Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Torres, Lucas Rios; Bretas, Elisa Almeida Sathler; Bekhor, Daniel; Medeiros, Regina Bitelli; D' Ippolito, Giuseppe, E-mail: ricardo.romano@unifesp.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Caldana, Rogerio Pedreschi [Fleury Medicina e Saude, Sao Paulo, SP (Brazil)

    2015-09-15

    Objective: To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters. Materials and Methods: Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A - 551 studies) and three months after (group B - 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDI{sub vol} per phase, mean DLP per phase, and mean DLP per scan. Results: A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDI{sub vol} per phase, DLP per phase and DLP per scan (p < 0.001). Conclusion: The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans. (author)

  5. Value of MR phase-contrast flow measurements for functional assessment of pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Ley, Sebastian; Mereles, Derliz; Gruenig, Ekkehard; Puderbach, Michael; Schoeck, Helena; Eichinger, Monika; Ley-Zaporozhan, Julia; Fink, Christian; Kauczor, Hans-Ulrich

    2007-01-01

    Goals of our study were to compare the pulmonary hemodynamics between healthy volunteers and patients with pulmonary arterial hypertension (PAH) and correlate MR flow measurements with echocardiography. Twenty-five patients with PAH and 25 volunteers were examined at 1.5 T. Phase-contrast flow measurements were performed in the ascending aorta and pulmonary trunk, resulting in the following parameters: peak velocity (cm/s), average blood flow (l/min), time to peak velocity (ms), velocity rise gradient and pulmonary distensibility (cm 2 ). The bronchosystemic shunt was calculated. In PAH patients transthoracic echocardiography and right-heart catheterization (RHC) served as the gold standard. In comparison to volunteers, the PAH patients showed significantly reduced pulmonary velocities (P = 0.002), blood flow (P = 0.002) and pulmonary distensibility (P = 0.008). In patients, the time to peak velocity was shorter (P<0.001), and the velocity rise gradient was steeper (P = 0.002) than in volunteers. While in volunteers the peak velocity in the aorta was reached earlier, it was the reverse in patients. Patients showed a significant bronchosystemic shunt (P = 0.01). No meaningful correlation was found between MRI measurements and echocardiography or RHC. MRI is a feasible technique for the differentiation between PAH and volunteers. Further studies have to be conducted for the absolute calculation of pressure estimates. (orig.)

  6. Dynamic contrast enhanced CT measurement of blood flow during interstitial laser photocoagulation: comparison with an Arrhenius damage model

    International Nuclear Information System (INIS)

    Purdie, T.J.; Lee, T.J.; Iizuka, M.; Sherar, M.D.

    2000-01-01

    One effect of heating during interstitial laser photocoagulation (ILP) is to directly destroy the tumour vasculature resulting in a loss of viable blood supply. Therefore, blood flow measured during and after treatment can be a useful indicator of tissue thermal damage. In this study, the effect of ILP treatment on rabbit thigh tumours was investigated by measuring blood flow changes using dynamic contrast enhanced computed tomography (CT). The CT measured changes in blood flow of treated tumour tissue were fitted to an Arrhenius model assuming first order rate kinetics. Our results show that changes in blood flow of tumour tissue distant from surrounding normal tissue are well described by an Arrhenius model. By contrast, the temperature profile of tumour tissue adjacent to normal tissue must be modified to account for heat dissipation by the latter. Finally, the Arrhenius parameters derived in the study are similar to those derived by heating tumour tissue to a lower temperature (<47 deg. C) than the current study. In conclusion, CT can be used to monitor blood flow changes during ILP and these measurements are related to the thermal damage predicted by the Arrhenius model. (author)

  7. Differential phase contrast setup for a non coherent beamline at HASYLAB using hard X-ray grating interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Herzen, Julia; Beckmann, Felix; Haibel, Astrid; Schreyer, Andreas [GKSS Research Centre, Geesthacht (Germany); Donath, Tilman; David, Christian; Gruenzweig, Christian [Paul Scherrer Institute, Villigen PSI (Switzerland); Pfeiffer, Franz [Paul Scherrer Institute, Villigen PSI (Switzerland); EPF Lausanne, Lausanne (Switzerland)

    2009-07-01

    Phase-contrast imaging is a common technique to visualize soft tissue with much higher contrast than the conventional absorption-contrast imaging. Differential phase contrast (DPC), developed at PSI, Switzerland, makes use of a hard x-ray grating interferometer and allows for phase-contrast imaging with high brilliance synchrotron sources as well as with conventional x-ray tubes. It is recently reported also to provide dark field information that is very sensitive to micro structures like porosity within the materials. Here we present the plans to adopt the DPC technique to the HARWI-II materials science beamline, operated by GKSS Research Centre, in cooperation with DESY, Hamburg. This will offer an amount of new applications especially in the field of materials science like for example characterizing new light weight materials like magnesium and studying its corrosion as implant material.

  8. In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs

    Energy Technology Data Exchange (ETDEWEB)

    Coan, Paola [Faculty of Medicine and Institute of Clinical Radiology, Ludwig-Maximilians University, Munich (Germany); Wagner, Andreas; Mollenhauer, Juergen [Department of Orthopaedics of the University of Jena, Rudolf-Elle-Hospital Eisenberg (Germany); Bravin, Alberto; Diemoz, Paul C; Keyrilaeinen, Jani, E-mail: Paola.Coan@physik.uni-muenchen.d [European Synchrotron Radiation Facility (ESRF), Grenoble (France)

    2010-12-21

    Over the last two decades phase contrast x-ray imaging techniques have been extensively studied for applications in the biomedical field. Published results demonstrate the high capability of these imaging modalities of improving the image contrast of biological samples with respect to standard absorption-based radiography and routinely used clinical imaging techniques. A clear depiction of the anatomic structures and a more accurate disease diagnosis may be provided by using radiation doses comparable to or lower than those used in current clinical methods. In the literature many works show images of phantoms and excised biological samples proving the high sensitivity of the phase contrast imaging methods for in vitro investigations. In this scenario, the applications of the so-called analyzer-based x-ray imaging (ABI) phase contrast technique are particularly noteworthy. The objective of this work is to demonstrate the feasibility of in vivo x-ray ABI phase contrast imaging for biomedical applications and in particular with respect to joint anatomic depiction and osteoarthritis detection. ABI in planar and tomographic modes was performed in vivo on articular joints of guinea pigs in order to investigate the animals with respect to osteoarthritis by using highly monochromatic x-rays of 52 keV and a low noise detector with a pixel size of 47 x 47 {mu}m{sup 2}. Images give strong evidence of the ability of ABI in depicting both anatomic structures in complex systems as living organisms and all known signs of osteoarthritis with high contrast, high spatial resolution and with an acceptable radiation dose. This paper presents the first proof of principle study of in vivo application of ABI. The technical challenges encountered when imaging an animal in vivo are discussed. This experimental study is an important step toward the study of clinical applications of phase contrast x-ray imaging techniques.

  9. Abdominal Aortic Emergencies.

    Science.gov (United States)

    Lech, Christie; Swaminathan, Anand

    2017-11-01

    This article discusses abdominal aortic emergencies. There is a common thread of risk factors and causes of these diseases, including age, male gender, hypertension, dyslipidemia, and connective tissue disorders. The most common presenting symptom of these disorders is pain, usually in the chest, flank, abdomen, or back. Computed tomography scan is the gold standard for diagnosis of pathologic conditions of the aorta in the hemodynamically stable patient. Treatment consists of a combination of blood pressure and heart rate control and, in many cases, emergent surgical intervention. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Use of lower abdominal compression to combat orthostatic hypotension in patients with autonomic dysfunction

    NARCIS (Netherlands)

    Smit, Adrianus A. J.; Wieling, Wouter; Fujimura, Jiro; Denq, Jong C.; Opfer-Gehrking, Tonette L.; Akarriou, Mohammed; Karemaker, John M.; Low, Phillip A.

    2004-01-01

    The aim of this study was to investigate in patients with neurogenic orthostatic hypotension the mechanism and usefulness of abdominal compression to increase standing blood pressure. in three protocols, 23 patients underwent abdominal compression. Protocol 1 evaluated in a 40-60degrees head-up-tilt

  11. In Vivo Assessment of the Potential for Renal Bio-Effects from the Vaporization of Perfluorocarbon Phase-Change Contrast Agents.

    Science.gov (United States)

    Nyankima, A Gloria; Rojas, Juan D; Cianciolo, Rachel; Johnson, Kennita A; Dayton, Paul A

    2018-02-01

    Low-boiling-point perfluorocarbon phase-change contrast agents (PCCAs) provide an alternative to microbubble contrast agents. Although parameter ranges related to in vivo bio-effects of microbubbles are fairly well characterized, few studies have been done to evaluate the potential of bio-effects related to PCCAs. To bridge this gap, we present an assessment of biological effects (e.g., hemorrhage) related to acoustically excited PCCAs in the rodent kidney. The presence or absence of bio-effects was observed after sonication with various perfluorocarbon core PCCAs (decafluorobutane, octafluoropropane or a 1:1 mixture) and as a function of activation pulse mechanical index (MI; minimum activation threshold, which was a moderate MI of 0.81-1.35 vs. a clinical maximum of 1.9). Bio-effects on renal tissue were assessed through hematology and histology including measurement of blood creatinine levels and the quantity of red blood cell (RBC) casts present in hematoxylin and eosin-stained kidney tissue sections after sonication. Short-term (24 h) and long-term (2 and 4 wk) analyses were performed after treatment. Results indicated that bio-effects from PCCA vaporization were not observed at lower mechanical indices. At higher mechanical indices, bio-effects were observed at 24 h, although these were not observable 2 wk after treatment. Copyright © 2018. Published by Elsevier Inc.

  12. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle.

    Directory of Open Access Journals (Sweden)

    Stefan Hindel

    Full Text Available The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles

  13. Restoration of the contrast of cerebral blood flows by the spatial deconvolution method

    International Nuclear Information System (INIS)

    Compingt, D.L.; Philippon, B.L.

    1982-01-01

    The measurement of regional cerebral blood flows (rCBF) with a gamma camera during xenon-133 inhalation necessitates collimators with high efficiency. Their spatial resolutions are weak: on the images given by a F.W.H.M. collimator (25 mm to 5 cm depth of water), the contrast restoration method by the ponctual dispersion function (P.D.F.) is used. The convolution product (Image)=(Object)*(P.D.F.) is resolved by a bidimensional Fast Fourier Transform treatment. The high frequencies are eliminated by a progressive filtration. The rCBF is calculated with Obrist's method. The Initial Slope Index is only used. A rCBF image with the calculator is also realized. The numerical values are compared with the normal treatment (N) without contrast restoration and after restoration. 22 patients are so treated after severe cerebral strokes. The hemispheric average of the flows according to the 2 treatments is unchanged (difference: 1.1%). The contrast between higher and lower flow areas is increasing by 73% after contrast restoration (significant difference: p [fr

  14. Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages

    Energy Technology Data Exchange (ETDEWEB)

    Euler, Andre; Stieltjes, Bram; Eichenberger, Reto; Reisinger, Clemens; Hirschmann, Anna; Zaehringer, Caroline; Kircher, Achim; Streif, Matthias; Bucher, Sabine; Buergler, David; D' Errico, Luigia; Kopp, Sebastien; Wilhelm, Markus [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Szucs-Farkas, Zsolt [Hospital Centre of Biel, Institute of Radiology, Biel (Switzerland); Schindera, Sebastian T. [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Cantonal Hospital Aarau, Institute of Radiology, Aarau (Switzerland)

    2017-12-15

    To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDI{sub vol}) was kept constant for all protocols. The datasets were reconstructed with MBIR and FBP. Image noise and contrast-to-noise-ratio (CNR) were assessed. Low-contrast lesion detectability was evaluated by 12 radiologists. MBIR decreased the image noise by 24% and 27%, and increased the CNR by 30% and 29% for the medium and large phantoms, respectively. Lower tube voltages increased the CNR by 58%, 46%, and 16% at 70, 80, and 100 kVp, respectively, compared with 120 kVp in the medium phantom and by 9%, 18% and 12% in the large phantom. No significant difference in lesion detection rate was observed (medium: 79-82%; large: 57-65%; P > 0.37). Although MBIR improved quantitative image quality compared with FBP, it did not result in increased low-contrast lesion detection in abdominal CT at different tube voltages in simulated medium and large patients. (orig.)

  15. Tuberculosis abdominal Abdominal tuberculosis

    OpenAIRE

    T. Rubio; M. T. Gaztelu; A. Calvo; M. Repiso; H. Sarasíbar; F. Jiménez Bermejo; A. Martínez Echeverría

    2005-01-01

    La tuberculosis abdominal cursa con un cuadro inespecífico, con difícil diagnóstico diferencial respecto a otras entidades de similar semiología. Presentamos el caso de un varón que ingresa por presentar dolor abdominal, pérdida progresiva y notoria de peso corporal y fiebre de dos meses de evolución. El cultivo de la biopsia de colon mostró presencia de bacilo de Koch.Abdominal tuberculosis develops according to a non-specific clinical picture, with a difficult differential diagnosis with re...

  16. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  17. Estimation of Abdominal Fat by Plasma Triglycerides and Carcass Dry Matter in Broiler Chicks

    Directory of Open Access Journals (Sweden)

    Javad Pour-Reza

    1997-04-01

    Full Text Available This experiment was carried out to determine the relationship of plasma triglycerides and carcass dry matter with abdominal fat. One of the problems of broiler is carcass fatness, especially abdominal fat due to rapid growth of broilers which is not the consumer preference. Six hundred one-day-old commercial broiler chicks (Lohman were divided into 40 groups, 15 chicks per group. Each one of the 10 experimental diets, in which barley was substituted for corn at levels of 0, 5, 10, 20 and 40%, was fed to 4 groups of chicks for 56 days. All diets were isoenergetic and isonitrogenous. Rice hulls was used to make diets isoenergetic. At days 42, 49 and 56, one male and one female were selected from each pen and after blood sampling, the birds were killed, eviscerated and percentages of carcass and amount of abdominal fats were measured. Blood samples were used to determine plasma triglycerides, cholesterol and total lipids. The results showed that increasing abdominal fat reduced carcass moisture content. Correlation between abdominal fat and plasma triglycerides was positive and significant (p<0.05. Correlation between abdominal fat and carcass moisture was negative and significant (P<0.01. The regression equations indicated that abdominal fat can be estimated from plasma triglycerides and carcass moisture content. The equations also indicated that using several parameters for estimating abdominal fat is better than single parameter estimation.

  18. Benchmarking the x-ray phase contrast imaging for ICF DT ice characterization using roughened surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Dewald, E; Kozioziemski, B; Moody, J; Koch, J; Mapoles, E; Montesanti, R; Youngblood, K; Letts, S; Nikroo, A; Sater, J; Atherton, J

    2008-06-26

    We use x-ray phase contrast imaging to characterize the inner surface roughness of DT ice layers in capsules planned for future ignition experiments. It is therefore important to quantify how well the x-ray data correlates with the actual ice roughness. We benchmarked the accuracy of our system using surrogates with fabricated roughness characterized with high precision standard techniques. Cylindrical artifacts with azimuthally uniform sinusoidal perturbations with 100 um period and 1 um amplitude demonstrated 0.02 um accuracy limited by the resolution of the imager and the source size of our phase contrast system. Spherical surrogates with random roughness close to that required for the DT ice for a successful ignition experiment were used to correlate the actual surface roughness to that obtained from the x-ray measurements. When comparing average power spectra of individual measurements, the accuracy mode number limits of the x-ray phase contrast system benchmarked against surface characterization performed by Atomic Force Microscopy are 60 and 90 for surrogates smoother and rougher than the required roughness for the ice. These agreement mode number limits are >100 when comparing matching individual measurements. We will discuss the implications for interpreting DT ice roughness data derived from phase-contrast x-ray imaging.

  19. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    Science.gov (United States)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  20. MR measurement of coronary arterial blood flow velocity. Evaluation of age, stenosis and drugs as factors affecting coronary blood flow

    International Nuclear Information System (INIS)

    Taoka, Yoshiaki; Harada, Masafumi; Nishitani, Hiromu; Yukinaka, Michiko; Nomura, Masahiro

    1998-01-01

    Coronary arterial blood flow velocity was measured using MRI. Two types of phase contrast methods were used for the measurements, one of which exhibited good resolving power whereas the other provided more distinct images acquired while the subject patients held their breath. Before measuring coronary arterial blood flow velocity, accuracy of the two phase contrast methods was evaluated using a phantom. The results obtained with both methods largely agreed with the values obtained using the phantom. Using both methods, the patterns of coronary arterial blood flow over one cardiac cycle were essentially identical. A peak was noted in late systole or in early diastole in the right coronary artery, whereas in the left coronary artery, a peak was noted somewhat later in diastole. In healthy volunteers, no significant difference in the maximal flow velocity in the coronary arteries was found from one age group to another. Among patients with coronary arterial stenosis, coronary arterial blood flow velocity central to the area of stenosis was lower than that observed in the healthy volunteers. Coronary arterial blood flow velocity was observed to decrease after administration of isosorbide dinitrate and increased following administration of nifedipine. (author)

  1. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

    Science.gov (United States)

    Nagayama, Yasunori; Tanoue, Shota; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Yoshida, Eri; Yoshida, Morikatsu; Kidoh, Masafumi; Tateishi, Machiko; Yamashita, Yasuyuki

    2018-05-01

    To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. We included 45 patients with renal dysfunction (estimated glomerular filtration rate  60 ml per lmin per 1.73 m 2 ) who underwent standard oncological abdominal-pelvic CT (600 mgI kg -1 , 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p 0.05). No significant kidney injury associated with CM administration was observed. 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

  2. High-resolution observation of phase contrast at 1MeV. Amorphous or crystalline objects

    International Nuclear Information System (INIS)

    Bourret, A.; Desseaux, J.

    1975-01-01

    Many authors have stressed the possibilities of high voltage to improve resolution, but owing to numerous experimental difficulties the resolution limit at 1MeV, which lies around 1A for conventional lenses, has so far been unattainable. Thus the phase contrast at 1MeV has not been studied on evaporated objects. On the other hand the fringes of crystal planes have been observed at 1MeV. the CEN-G microscope having been considerably modified it has been possible to observe the phase contrast of amorphous or crystalline objects [fr

  3. Pleural Effusion Resultant after Upper Abdominal Surgery: Analysis of 47 Cases

    Directory of Open Access Journals (Sweden)

    Ufuk Cobanoglu

    2011-09-01

    Full Text Available Postoperative pulmonary complications, following upper abdominal surgery, occur at a rate which is higher, than lower abdominal surgery. One of these complications is pleural effusion. In this study, the frequency and causes of pleural effusions and the changes of the blood gas values and pulmonary functions of the patients with pleural effusions, occured after upper abdominal surgery are discussed in the accompaniment of the literature. Material and Methods:148 patients to whom upper adominal surgery is performed and in 47 of these patients pleural effusion is developed (31.75% , were examined restrospectivitely. Preoperative and postoperative pulmonary function tests (PFT and arterial blood gas (ABG results and the blood proteins, albumin values were recorded. The anesthesia type, the surgery properties, involving type of surgery and the surgical incision were determined. Results:Pleural effusion is detected bilaterally in 8 patients (17:02, at the rightside in 21 patients (44.69% ,and at the left side in 18 patients (38.29%.The 40.42% (19 cases of the patients who has pleural effusion in the postoperative period, had liver and gallbladder surgery, the %23.41 (11 Cases had spleen and pancreas surgery and the %36.17 (17 cases had the  other surgical procedures.Conclusions: While the upper abdominal surgery, impairment of the integrity of the diaphragm‘s peritoneum that covers the abdominal cavity where there is a highliquid pressure, may cause the liquid transition to the pleural space that has a negative pressure. Hypoalbuminemia and hipoproteinemia, that will occur due to the changes of oral intake and diet regulation in the postoperative period, may cause a reason for the pleural effusion. For this reason, doctors who performed these surgery procedures, should not ignore this complication, in the period of postoperative follow-ups of the patients.

  4. Revising the lower statistical limit of x-ray grating-based phase-contrast computed tomography.

    Science.gov (United States)

    Marschner, Mathias; Birnbacher, Lorenz; Willner, Marian; Chabior, Michael; Herzen, Julia; Noël, Peter B; Pfeiffer, Franz

    2017-01-01

    Phase-contrast x-ray computed tomography (PCCT) is currently investigated as an interesting extension of conventional CT, providing high soft-tissue contrast even if examining weakly absorbing specimen. Until now, the potential for dose reduction was thought to be limited compared to attenuation CT, since meaningful phase retrieval fails for scans with very low photon counts when using the conventional phase retrieval method via phase stepping. In this work, we examine the statistical behaviour of the reverse projection method, an alternative phase retrieval approach and compare the results to the conventional phase retrieval technique. We investigate the noise levels in the projections as well as the image quality and quantitative accuracy of the reconstructed tomographic volumes. The results of our study show that this method performs better in a low-dose scenario than the conventional phase retrieval approach, resulting in lower noise levels, enhanced image quality and more accurate quantitative values. Overall, we demonstrate that the lower statistical limit of the phase stepping procedure as proposed by recent literature does not apply to this alternative phase retrieval technique. However, further development is necessary to overcome experimental challenges posed by this method which would enable mainstream or even clinical application of PCCT.

  5. Quantitative tracking of tumor cells in phase-contrast microscopy exploiting halo artifact pattern

    Science.gov (United States)

    Kang, Mi-Sun; Song, Soo-Min; Lee, Hana; Kim, Myoung-Hee

    2012-03-01

    Tumor cell morphology is closely related to its invasiveness characteristics and migratory behaviors. An invasive tumor cell has a highly irregular shape, whereas a spherical cell is non-metastatic. Thus, quantitative analysis of cell features is crucial to determine tumor malignancy or to test the efficacy of anticancer treatment. We use phase-contrast microscopy to analyze single cell morphology and to monitor its change because it enables observation of long-term activity of living cells without photobleaching and phototoxicity, which is common in other fluorescence-labeled microscopy. Despite this advantage, there are image-level drawbacks to phase-contrast microscopy, such as local light effect and contrast interference ring, among others. Thus, we first applied a local filter to compensate for non-uniform illumination. Then, we used intensity distribution information to detect the cell boundary. In phase-contrast microscopy images, the cell normally appears as a dark region surrounded by a bright halo. As the halo artifact around the cell body is minimal and has an asymmetric diffusion pattern, we calculated the cross-sectional plane that intersected the center of each cell and was orthogonal to the first principal axis. Then, we extracted the dark cell region by level set. However, a dense population of cultured cells still rendered single-cell analysis difficult. Finally, we measured roundness and size to classify tumor cells into malignant and benign groups. We validated segmentation accuracy by comparing our findings with manually obtained results.

  6. ABDOMINAL OBESITY, AN ANTHROPOMETRIC PARAMETER PREDICTING METABOLIC DISORDERS

    Directory of Open Access Journals (Sweden)

    Maricel Castellanos González

    2011-08-01

    Full Text Available Background: Waist circumference perimeter, as an indirect indicator of abdominal obesity, is commonly presented as an essential element in the clinical assessment of obesity. The link between abdominal obesity and insulin resistance is proposed as the core of metabolic syndrome’s pathophysiology and complications. Objective: To determine whether individuals with abdominal obesity present characteristics related to metabolic syndrome’s factors that differ from those observed in individuals with no abdominal obesity. Methods: A comparative analytical study was performed including cases control and design in two different groups. The sample was composed of 98 individuals of both sexes randomly selected out of a universe of 510 workers population at the Medical University of Cienfuegos from September to December 2005. They were all tested as to blood pressure, cholesterol, HDL cholesterol, fasting glucose and triglycerides. Results: Abdominal obesity was found in 30.6% of individuals. It was predominant in females (83.3% older than 40 years. The number of cases of obesity linked to hypertension was similar to the number of cases with low HDL cholesterol (53.3%. Impaired glucose was found in 16.7% of cases. Conclusions: Abdominal obesity is a health problem in the population included in this study and it increases as age does. Individuals with abdominal obesity are exposed to a higher risk of metabolic disorders, such as low levels of HDL cholesterol, high levels of triglycerides and total cholesterol, glucose alterations and hypertension.

  7. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Science.gov (United States)

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development

  8. Age and gender related differences in aortic blood flow

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation of the artery with fatal consequences if left untreated. The blood flow patterns in the AA is thought to play an important role in the development of AAA. The purpose of this work is to investi......The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation of the artery with fatal consequences if left untreated. The blood flow patterns in the AA is thought to play an important role in the development of AAA. The purpose of this work...... is to investigate the blood flow pat- terns within a group of healthy volunteers (4 females, 7 males) aged 23 to 76 years to identify changes and differences related to age and gender. The healthy volunteers were categorized by gender (male/female) and age (below/above 35 years). Subject-specific flow and geometry...... to elderly. Thus, changes in blood flow patterns in the AA related to age and gender is observed. Further investigations are needed to determine the relation between changes in blood flow patterns and AAA development....

  9. Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance

    OpenAIRE

    McLaughlin, P. D.; Murphy, K. P.; Hayes, S. A.; Carey, K.; Sammon, J.; Crush, L.; O’Neill, F.; Normoyle, B.; McGarrigle, A. M.; Barry, J. E.; Maher, M. M.

    2014-01-01

    Objectives The aim was to assess the performance of low-dose non-contrast CT of the urinary tract (LD-CT) acquired at radiation exposures close to that of abdominal radiography using adaptive statistical iterative reconstruction (ASiR). Methods Thirty-three patients with clinically suspected renal colic were prospectively included. Conventional dose (CD-CT) and LD-CT data sets were contemporaneously acquired. LD-CT images were reconstructed with 40 %, 70 % and 90 % ASiR. Image quality was sub...

  10. Reprodaetion of an animal model of multiple intestinal injuries mimicking "lethal triad" caused by severe penetrating abdominal trauma

    Directory of Open Access Journals (Sweden)

    Peng-fei WANG

    2011-03-01

    Full Text Available Objective To reproduce an animal model of multi-intestinal injuries with "lethal triad" characterized by low body temperature,acidosis and coagulopathy.Methods Six female domestic outbred pigs were anesthetized,and the carotid artery and jugular vein were cannulated for monitoring the blood pressure and heart rate and for infusion of fluid.The animals were shot with a gun to create a severe penetrating abdominal trauma.Immediately after the shooting,50% of total blood volume(35ml/kg hemorrhage was drawn from the carotid artery in 20min.After a 40min shock period,4h of pre-hospital phase was mimicked by normal saline(NS resuscitation to maintain systolic blood pressure(SBP > 80mmHg or mean arterial pressure(MAP > 60mmHg.When SBP > 80mmHg or MAP > 60mmHg,no fluid infusion or additional bleeding was given.Hemodynamic parameters were recorded,and pathology of myocardium,lung,small intestine and liver was observed.Results There were multiple intestinal perforations(8-10 site injuries/pig leading to intra-abdominal contamination,mesenteric injury(1-2 site injuries/pig resulted in partial intestinal ischemia and intra-abdominal hemorrhage,and no large colon and mesenteric vascular injury.One pig died before the completion of the model establishment(at the end of pre-hospital resuscitation.The typical symptoms of trauma-induced hemorrhagic shock were observed in survival animals.Low temperature(33.3±0.5℃,acidosis(pH=7.242±0.064,and coagulopathy(protrombin time and activated partial thromboplasting time prolonged were observed after pre-hospital resuscitation.Pathology showed that myocardium,lung,small intestine and liver were severely injured.Conclusions A new model,simulating three stages of "traumatic hemorrhagic shock,pre-hospital recovery and hospital treatment" and inducing the "lethal triad" accompanied with abdominal pollution,has been successfully established.This model has good stability and high reproducibility.The survival animals can be

  11. Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent : Initial experience

    NARCIS (Netherlands)

    Bedaux, WLF; Hofman, MBM; Wielopolski, PA; de Cock, CC; Hoffmann, [No Value; Oudkerk, M; de Feyter, PJ; van Rossum, AC

    2002-01-01

    Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the

  12. Simultaneous acquisition of dual analyser-based phase contrast X-ray images for small animal imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Pavlov, Konstantin M.; Hooper, Stuart B.; Vine, David J.; Siu, Karen K.W.; Wallace, Megan J.; Siew, Melissa L.L.; Yagi, Naoto; Uesugi, Kentaro; Lewis, Rob A.

    2008-01-01

    Analyser-based phase contrast X-ray imaging can provide high-contrast images of biological tissues with exquisite sensitivity to the boundaries between tissues. The phase and absorption information can be extracted by processing multiple images acquired at different analyser orientations. Recording both the transmitted and diffracted beams from a thin Laue analyser crystal can make phase retrieval possible for dynamic systems by allowing full field imaging. This technique was used to image the thorax of a mechanically ventilated newborn rabbit pup using a 25 keV beam from the SPring-8 synchrotron radiation facility. The diffracted image was produced from the (1 1 1) planes of a 50 mm x 40 mm, 100 μm thick Si analyser crystal in the Laue geometry. The beam and analyser were large enough to image the entire chest, making it possible to observe changes in anatomy with high contrast and spatial resolution

  13. Simultaneous acquisition of dual analyser-based phase contrast X-ray images for small animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kitchen, Marcus J. [School of Physics, Monash University, Victoria 3800 (Australia)], E-mail: Marcus.Kitchen@sci.monash.edu.au; Pavlov, Konstantin M. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia); Physics and Electronics, School of Science and Technology, University of New England, NSW 2351 (Australia)], E-mail: Konstantin.Pavlov@sci.monash.edu.au; Hooper, Stuart B. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Stuart.Hooper@med.monash.edu.au; Vine, David J. [School of Physics, Monash University, Victoria 3800 (Australia)], E-mail: David.Vine@sci.monash.edu.au; Siu, Karen K.W. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia)], E-mail: Karen.Siu@sci.monash.edu.au; Wallace, Megan J. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Megan.Wallace@med.monash.edu.au; Siew, Melissa L.L. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Melissa.Siew@med.monash.edu.au; Yagi, Naoto [SPring-8/JASRI, Sayo (Japan)], E-mail: yagi@spring8.or.jp; Uesugi, Kentaro [SPring-8/JASRI, Sayo (Japan)], E-mail: ueken@spring8.or.jp; Lewis, Rob A. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia)], E-mail: Rob.Lewis@sync.monash.edu.au

    2008-12-15

    Analyser-based phase contrast X-ray imaging can provide high-contrast images of biological tissues with exquisite sensitivity to the boundaries between tissues. The phase and absorption information can be extracted by processing multiple images acquired at different analyser orientations. Recording both the transmitted and diffracted beams from a thin Laue analyser crystal can make phase retrieval possible for dynamic systems by allowing full field imaging. This technique was used to image the thorax of a mechanically ventilated newborn rabbit pup using a 25 keV beam from the SPring-8 synchrotron radiation facility. The diffracted image was produced from the (1 1 1) planes of a 50 mm x 40 mm, 100 {mu}m thick Si analyser crystal in the Laue geometry. The beam and analyser were large enough to image the entire chest, making it possible to observe changes in anatomy with high contrast and spatial resolution.

  14. Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies

    Energy Technology Data Exchange (ETDEWEB)

    Hetterich, Holger; Fill, Sandra [Klinikum der Ludwig-Maximilians-Univ., Muenchen (Germany). Inst. fuer Klinische Radiologie; Herzen, Julia [Technische Univ. Muenchen, Garching (Germany). Physik-Dept. und Inst. fuer Medizintechnik; Helmholtz-Zentrum Geesthacht, Geesthacht (Germany). Zentrum fuer Materialforschung] [and others

    2013-10-01

    Background: Tissue characterization of atherosclerosis by absorption-based imaging methods is limited due to low soft-tissue contrast. Grating-based phase-contrast computed tomography (PC-CT) may become an alternative for plaque assessment if the phase signal can be retrieved at clinically applicable photon energies. The aims of this feasibility study were (i) to characterize arterial vessels at low and high photon energies, (ii) to extract qualitative features and (iii) quantitative phase-contrast Hounsfield units (HU-phase) of plaque components at 53 keV using histopathology as gold standard. Materials and methods: Five human carotid artery specimens underwent grating-based PC-CT using synchrotron radiation of either 23 keV or 53 keV and histological work-up. Specimens without advanced atherosclerosis were used to extract signal criteria of vessel layers. Diseased specimens were screened for important plaque components including fibrous tissue (FT), lipid (LIP), necrotic core (NEC), intraplaque hemorrhage (IPH), inflammatory cell infiltration (INF) and calcifications (CA). Qualitative features as well as quantitative HU-phase were analyzed. Results: Thirty-three regions in 6 corresponding PC-CT scans and histology sections were identified. Healthy samples had the same signal characteristics at 23 keV and 53 keV with bright tunica intima and adventitia and dark media. Plaque components showed differences in signal intensity and texture at 53 keV. Quantitative analysis demonstrated the highest HU-phase of soft plaque in dense FT. Less organized LIP, NEC and INF were associated with lower HU-phase values. The highest HU-phase were measured in CA. Conclusion: PC-CT of atherosclerosis is feasible at high, clinically relevant photon energies and provides detailed information about plaque structure including features of high risk vulnerable plaques. (orig.)

  15. Phase-contrast X-ray CT imaging of the kidney. Differences between ethanol fixation and formalin fixation

    International Nuclear Information System (INIS)

    Shirai, Ryota; Kunii, Takuya; Maruyama, Hiroko; Takeda, Tohoru; Yoneyama, Akio; Lwin, Thet Thet

    2012-01-01

    A phase-contrast X-ray imaging technique using an X-ray interferometer that provides approximately 1000 times higher sensitivity than the conventional X-ray imaging method for low-atomic number elements based on the difference in the mass attenuation coefficient has recently been developed. In the present study, we compared rat kidneys fixed in 100% ethanol and in 10% formalin to evaluate the effects of ethanol in enhancing image contrast in phase-contrast imaging because ethanol causes significant dehydration of tissues and enhances density differences between tissue components. The experiments were conducted at the Photon Factory in Tsukuba, and the X-ray energy was set at 35 keV. Fine anatomical structures in the kidney such as the glomeruli, tubules, and vessels were observed. Particularly clear renal images were obtained with ethanol fixation. The pixel value ratio between the cortex and medulla was about 43% in ethanol-fixed kidneys and 21% in formalin-fixed kidneys. In other words, the contrast in ethanol-fixed kidneys was about two times higher than that in formalin-fixed kidneys. Histological examination showed significantly condensed features in the cortex. The results of this study suggest that the ethanol fixation technique may be useful for enhancing the image contrast of renal structures in the phase-contrast X-ray imaging technique. (author)

  16. Approximated transport-of-intensity equation for coded-aperture x-ray phase-contrast imaging.

    Science.gov (United States)

    Das, Mini; Liang, Zhihua

    2014-09-15

    Transport-of-intensity equations (TIEs) allow better understanding of image formation and assist in simplifying the "phase problem" associated with phase-sensitive x-ray measurements. In this Letter, we present for the first time to our knowledge a simplified form of TIE that models x-ray differential phase-contrast (DPC) imaging with coded-aperture (CA) geometry. The validity of our approximation is demonstrated through comparison with an exact TIE in numerical simulations. The relative contributions of absorption, phase, and differential phase to the acquired phase-sensitive intensity images are made readily apparent with the approximate TIE, which may prove useful for solving the inverse phase-retrieval problem associated with these CA geometry based DPC.

  17. Diagnostic accuracy of non-contrast abdominal CT scans performed as follow-up for patients with an established cancer diagnosis: a retrospective study.

    Science.gov (United States)

    Semaan, Hassan; Bazerbashi, Mohamad F; Siesel, Geoffrey; Aldinger, Paul; Obri, Tawfik

    2018-03-01

    To determine the accuracy and non-detection rate of cancer related findings (CRFs) on follow-up non-contrast-enhanced CT (NECT) versus contrast-enhanced CT (CECT) images of the abdomen in patients with a known cancer diagnosis. A retrospective review of 352 consecutive CTs of the abdomen performed with and without IV contrast between March 2010 and October 2014 for follow-up of cancer was included. Two radiologists independently assessed the NECT portions of the studies. The reader was provided the primary cancer diagnosis and access to the most recent prior NECT study. The accuracy and non-detection rates were determined by comparing our results to the archived reports as a gold standard. A total of 383 CRFs were found in the archived reports of the 352 abdominal CTs. The average non-detection rate for the NECTs compared to the CECTs was 3.0% (11.5/383) with an accuracy of 97.0% (371.5/383) in identifying CRFs. The most common findings missed were vascular thrombosis with a non-detection rate of 100%. The accuracy for non-vascular CRFs was 99.1%. Follow-up NECT abdomen studies are highly accurate in the detection of CRFs in patients with an established cancer diagnosis, except in cases where vascular involvement is suspected.

  18. Abdominal Obesity, Race and Chronic Kidney Disease in Young Adults: Results from NHANES 1999-2010.

    Science.gov (United States)

    Sarathy, Harini; Henriquez, Gabriela; Abramowitz, Matthew K; Kramer, Holly; Rosas, Sylvia E; Johns, Tanya; Kumar, Juhi; Skversky, Amy; Kaskel, Frederick; Melamed, Michal L

    2016-01-01

    Kidney dysfunction in obesity may be independent of and may precede the development of hypertension and/or diabetes mellitus. We aimed to examine if abdominal obesity is associated with early markers of CKD in a young healthy population and whether these associations differ by race and/or ethnicity. We analyzed data from the NHANES 1999-2010 for 6918 young adults ages 20-40 years. Abdominal obesity was defined by gender criteria of waist circumference. CKD markers included estimated glomerular filtration rate and albuminuria ≥30 mg/g. Race stratified analyses were done overall and in subgroups with normal blood pressures, normoglycemia and normal insulin sensitivity. Awareness of CKD was assessed in participants with albuminuria. Abdominal obesity was present in over one-third of all young adults and was more prevalent among non-Hispanic blacks (45.4%) versus Mexican-Americans (40.6%) or non-Hispanic whites (37.4%) (P-value = 0.004). Mexican-American young adults with abdominal obesity had a higher odds of albuminuria even among those with normal blood pressure, normal glucose, and normal insulin sensitivity [adjusted odds ratio 4.5; 95% confidence interval (1.6-12.2), p = 0.004]. Less than 5% of young adults with albuminuria of all races and ethnicities had been told they had kidney disease. Abdominal obesity in young adults, especially in Mexican-Americans, is independently associated with albuminuria even with normal blood pressures, normoglycemia and normal insulin levels. Greater awareness of CKD is needed to protect this young population from long-standing exposure to abdominal obesity and early progressive renal disease.

  19. Abdominal Obesity, Race and Chronic Kidney Disease in Young Adults: Results from NHANES 1999-2010.

    Directory of Open Access Journals (Sweden)

    Harini Sarathy

    Full Text Available Kidney dysfunction in obesity may be independent of and may precede the development of hypertension and/or diabetes mellitus. We aimed to examine if abdominal obesity is associated with early markers of CKD in a young healthy population and whether these associations differ by race and/or ethnicity.We analyzed data from the NHANES 1999-2010 for 6918 young adults ages 20-40 years. Abdominal obesity was defined by gender criteria of waist circumference. CKD markers included estimated glomerular filtration rate and albuminuria ≥30 mg/g. Race stratified analyses were done overall and in subgroups with normal blood pressures, normoglycemia and normal insulin sensitivity. Awareness of CKD was assessed in participants with albuminuria.Abdominal obesity was present in over one-third of all young adults and was more prevalent among non-Hispanic blacks (45.4% versus Mexican-Americans (40.6% or non-Hispanic whites (37.4% (P-value = 0.004. Mexican-American young adults with abdominal obesity had a higher odds of albuminuria even among those with normal blood pressure, normal glucose, and normal insulin sensitivity [adjusted odds ratio 4.5; 95% confidence interval (1.6-12.2, p = 0.004]. Less than 5% of young adults with albuminuria of all races and ethnicities had been told they had kidney disease.Abdominal obesity in young adults, especially in Mexican-Americans, is independently associated with albuminuria even with normal blood pressures, normoglycemia and normal insulin levels. Greater awareness of CKD is needed to protect this young population from long-standing exposure to abdominal obesity and early progressive renal disease.

  20. Imaging of small bowel-related complications following major abdominal surgery

    International Nuclear Information System (INIS)

    Sandrasegaran, Kumaresan; Maglinte, Dean D.T.

    2005-01-01

    To recognize and document the small bowel reactions following major abdominal surgery is an important key for a correct diagnosis. Usually, plain abdominal radiography is the initial imaging examination requested in the immediate postoperative period, whereas gastrointestinal contrast studies are used to look for specific complications. In some countries, especially in Europe, sonography is widely employed to evaluate any acute affection of the abdomen. CT is commonly used to assess postoperative abdominal complications; in our institution also CT enteroclysis is often performed, to provide additional important informations. Radiologist should be able to diagnose less common types of obstruction, such as afferent loop, closed loop, strangulating obstruction as well as internal hernia. This knowledge may assume a critical importance for surgeons to decide on therapy. In this article, we focus our attention on the imaging (particularly CT) in small bowel complications following abdominal surgery